Chen, Jien-Jiun; Lin, Lian-Yu; Yang, Yao-Hsu; Hwang, Juey-Jen; Chen, Pau-Chung; Lin, Jiunn-Lee; Chi, Nai-Hsin
2017-01-15
The usage of on or off cardiopulmonary bypass in patients with coronary artery disease receiving coronary artery bypass grafting (CABG) surgery had been debated and had not yet been investigated thoroughly in patients with end-stage renal disease (ESRD). We aimed to study cardiovascular outcomes and total mortality in these patients by using our National Health Insurance (NHI) database. By using our NHI ESRD claim database, we searched ESRD patients aged more than 18years, who received CABG and divided them into on pump and off pump groups. Baseline characteristics and underlying comorbidities were identified from the database. Propensity score (PS) method was used to match all the potential confounders between patients. Outcomes including mortality, myocardial infarction, stroke and repeat revascularization within 30days, 1year and whole follow-up period were also obtained. A total of 134,410 ESRD patients were identified in the database. We included 341 patients and 543 patients who received off pump and on pump CABG respectively. The hazard ratios of different outcomes at 30days, 1year and a median of 745days after CABG did not show significant different between on, or off pump groups before and after PS match. ESRD patients with CAD undergoing either on pump or off pump CABG surgery showed similar outcomes in 30days, 1year and whole follow-up period. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Off-pump coronary artery bypass surgery in severe left ventricular dysfunction.
Azarfarin, Rasoul; Pourafkari, Leili; Parvizi, Rezayat; Alizadehasl, Azin; Mahmoodian, Roghaiyeh
2010-02-01
Our aim was to examine hospital outcomes of coronary artery bypass surgery in patients with and without left ventricular dysfunction, with regard to the surgical technique (off- or on-pump). Between March 2007 and March 2008, 689 consecutive patients underwent isolated first-time coronary artery bypass; 127 had ejection fractions < or = 30% (group 1) and 562 had ejection fractions >30% (group 2). Data of preoperative risk profiles and hospital outcomes were collected prospectively. Off-pump operations were performed in 49 (38.6%) patients in group 1 and 196 (34.9%) in group 2. The incidences of infectious, neurologic, and cardiac complications postoperatively were significantly higher in group 1. In multivariate analysis, preoperative ejection fraction < or = 30% was found to be an independent risk factor for postoperative complications and hospital mortality. The subgroup of patients undergoing off-pump surgery in both groups had a significantly lower rate of total complications than those undergoing conventional on-pump operations, but no significant difference in mortality was observed between those undergoing off-pump or conventional surgery in either group. Off-pump surgery helped to limit the increased morbidity rate after coronary bypass in patients with ventricular dysfunction.
Transapical aortic valve implantation and minimally invasive off-pump bypass surgery
Ahad, Samir; Baumbach, Hardy; Hill, Stephan; Franke, Ulrich F. W.
2014-01-01
Transcatheter aortic valve implantation (TAVI) has gained increasing popularity for high-risk patients with symptomatic aortic valve stenosis. A concomitant coronary artery disease leads to a complicated management and an increased perioperative risk. This case report describes the successful total arterial coronary revascularization of the left anterior descending and the left marginal branch of the circumflex artery utilizing the left internal mammary artery (LIMA) and left radial artery in off-pump technique in combination with the transapical transcatheter aortic valve implantation via minimally invasive anterolateral access in the fifth intercostal space. PMID:24221960
Target vessel detection by epicardial ultrasound in off-pump coronary bypass surgery.
Hayakawa, Masato; Asai, Tohru; Kinoshita, Takeshi; Suzuki, Tomoaki; Shiraishi, Shoichiro
2013-01-01
The detection of embedded coronary arteries is difficult especially in off-pump coronary bypass surgery. From June 2010, we introduced high-frequency epicardial ultrasound (ECUS) to assess and evaluate embedded arteries during off-pump coronary bypass surgery. Between June 2010 and June 2011, a total of 89 consecutive patients underwent isolated coronary bypass surgery at our institution. The patients consisted of 72 men and 17 women with a mean age of 67.9 years. We routinely use the VeriQC system (MediStim, Oslo, Norway) to detect the target vessels in the operation. The patients were assigned to one of two groups, depending on whether ECUS was used in the operation (n = 10, ECUS group) or not (n = 79, non-ECUS group). We analyzed the impact of introducing the ECUS in terms of operative outcome. All patients underwent revascularization using the off-pump technique without emergent conversion to cardiopulmonary bypass during surgery. The total number of distal anastomoses was 299, and 12 target vessels could not be identified either visually or on palpation. Thus, the frequency of the embedded coronary arteries was 4.01% (12/299 cases). The preoperative profiles of the two groups were not significantly different. Operation time was significantly longer in the ECUS group (P = 0.02). There were no significant differences in postoperative outcome between the two groups. In the present study, in which the target coronary arteries could not be detected either visually or on palpation in 12 (4.01%) of 299 cases, the use of high-frequency ECUS allowed all patients to undergo off-pump coronary bypass surgery without conversion to cardiopulmonary bypass during the operation. High-frequency ECUS is therefore useful in off-pump coronary bypass surgery.
Benedetto, Umberto; Caputo, Massimo; Vohra, Hunaid; Davies, Alan; Hillier, James; Bryan, Alan; Angelini, Gianni D
2016-11-01
We conducted a single-center analysis on short-term outcomes and long-term survival in actively treated diabetic patients undergoing off-pump coronary artery bypass versus on-pump coronary artery bypass surgery. The final population consisted of 2450 patients with actively treated diabetes (mean age, 66 ± 9 years; female/male 545/1905, 22%). Of those, 1493 subjects were orally treated and 1011 subjects were taking insulin. Off-pump coronary artery bypass and on-pump coronary artery bypass were performed in 1253 and 1197 patients, respectively. Propensity score matching was used to compare the 2 matched groups. When compared with on-pump coronary artery bypass, off-pump coronary artery bypass was associated with a significant risk reduction for postoperative cerebrovascular accident (odds ratio, 0.49; 95% confidence interval [CI], 0.25-0.99; P = .04), need for postoperative intra-aortic balloon pump (odds ratio, 0.48; 95% CI, 0.30-0.77; P = .002), and reexploration for bleeding (odds ratio, 0.55; 95% CI, 0.33-0.94; P = .02). Off-pump coronary artery bypass did not significantly affect early (hazard ratio [HR], 1.32; 95% CI, 0.73-2.40; P = .36) and late (HR, 1.08; 95% CI, 0.92-1.28; P = .32) mortality. However, off-pump coronary artery bypass with incomplete revascularization was associated with reduced survival when compared with off-pump coronary artery bypass with complete revascularization (HR, 1.82; 95% CI, 1.34-2.46; P = .0002) and on-pump coronary artery bypass with complete revascularization (HR, 1.83; 95% CI, 1.36-2.47; P < .0001). Off-pump coronary artery bypass is a safe and feasible option for diabetic patients with multivessel disease, reduces the incidence of early complications including postoperative cerebrovascular events, and provides excellent long-term survival similar to on-pump coronary artery bypass surgery in case of complete revascularization. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.
Lushaj, Entela B; Schreiner, Athanasia; Jonuzi, Besa; Badami, Abbasali; DeOliveira, Nilto; Lozonschi, Lucian
2016-05-17
We retrospectively assessed the outcomes after coronary revascularization at a single Veterans Affairs Medical Center when a strategy of assigning higher risk patients to off-pump coronary artery bypass grafting (CABG) was employed. Over a 5 year period all consecutive patients that underwent CABG at our VA Medical Center were assigned to a surgeon who either performs the CABG exclusively off-pump or to one who performed the CABG on-pump. The higher risk patients were assigned preferentially for off-pump revascularization. VASQIP (VA Hospitals Surgical Quality Improvement Program) data between 10/2007 and 12/2012 were retrospectively reviewed at our VA Medical Center and the short term outcomes were assessed. A total of 252 consecutive patients underwent off-pump CABG (n = 170) and on-pump CABG (n = 82). There were significantly more patients with low LVEF (<45 %; p = 0.008) and cerebrovascular disease in the off-pump group (p = 0.024). The number of patients smoking at the time of surgery was significantly higher in the off-pump group (p = 0.002) as well. The 30-day composite morbidity and mortality was 6 % for all CABG patients and significantly lower with off-pump vs. on-pump CABG (3.5 % vs. 11 %; p = 0.019). There were no conversions from off-pump to on-pump surgery. A selective strategy to direct higher risk patients towards an off-pump revascularization yielded favorable outcomes in an unselected veteran population treated at a single VA Medical Center over a 5 year period.
Misfeld, Martin; Brereton, R John L; Sweetman, Elizabeth A; Doig, Gordon S
2011-08-01
Neurologic complications after coronary artery bypass grafting remain a concern. Off-pump coronary artery bypass grafting is a surgical strategy proposed to decrease this risk. Use of an off-pump anaortic technique, which leaves the ascending aorta untouched, may result in further reductions. This systematic review of all published evidence compares neurologic complications after anaortic off-pump coronary artery bypass grafting versus that with aortic manipulation. PubMed and Embase were searched up to August 2008. Experts were contacted, and reference lists of retrieved articles were hand searched. The search process was not limited to English-language sources. Observational studies comparing standard off-pump coronary artery bypass grafting technique with anaortic technique were eligible for inclusion if they reported neurologic complications (stroke and transient ischemic attack). Meta-analysis was conducted to assess differences between groups with regard to neurologic complications. Electronic search identified 1428 abstracts, which resulted in retrieval and detailed review of 331 full-text articles. Eight observational studies reported neurologic complications in 5619 anaortic off-pump coronary artery bypass grafting cases and 5779 cases with aortic manipulation. Postsurgical neurologic complications were significantly lower in anaortic off-pump coronary artery bypass grafting cases (odds ratio, 0.46; 95% confidence interval, 0.29-0.72; I(2) = 0.8%; P = .0008). Avoidance of aortic manipulation during off-pump coronary artery bypass grafting decreases neurologic complications relative to standard technique in which the ascending aorta is manipulated. In patients at high risk for stroke or transient ischemic attack, we recommend avoidance of aortic manipulation during off-pump coronary artery bypass grafting. Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Does off-pump coronary surgery reduce morbidity and mortality?
Sabik, Joseph F; Gillinov, A Marc; Blackstone, Eugene H; Vacha, Catherine; Houghtaling, Penny L; Navia, Jose; Smedira, Nicholas G; McCarthy, Patrick M; Cosgrove, Delos M; Lytle, Bruce W
2002-10-01
To compare hospital outcomes of on-pump and off-pump coronary artery bypass surgery. From 1997 to 2000, primary coronary artery bypass grafting was performed in 481 patients off pump and in 3231 patients on pump. Hospital outcomes were compared between propensity-matched pairs of 406 on-pump and 406 off-pump patients. The 2 groups were similar in age (P =.9), left ventricular function (P =.7), extent of coronary artery disease (P =.5), carotid artery disease (P =.4), and chronic obstructive pulmonary disease (P =.5). However, off-pump patients had more previous strokes (P =.05) and peripheral vascular disease (P =.02); on-pump patients had a higher preoperative New York Heart Association class (P =.01). In the matched pairs the mean number of bypass grafts was 2.8 +/- 1.0 in off-pump patients and 3.5 +/- 1.1 in on-pump patients (P <.001). Fewer grafts were performed to the circumflex (P <.001) and right coronary (P =.006) artery systems in the off-pump patients. Postoperative mortality, stroke, myocardial infarction, and reoperation for bleeding were similar in the 2 groups. There was more encephalopathy (P =.02), sternal wound infection (P =.04), red blood cell use (P =.002), and renal failure requiring dialysis (P =.03) in the on-pump patients. Both off- and on-pump procedures produced excellent early clinical results with low mortality. An advantage of an off-pump operation was less postoperative morbidity; however, less complete revascularization introduced uncertainty about late results. A disadvantage of on-pump bypass was higher morbidity that seemed attributable to cardiopulmonary bypass.
Brinkman, William T; Squiers, John J; Filardo, Giovanni; Arsalan, Mani; Smith, Robert L; Moore, David; Mack, Michael J; DiMaio, J Michael
2015-12-01
Mini-extracorporeal circulation (MECC) units were developed to reduce postoperative morbidity, transfusion requirements, and inflammation associated with conventional on-pump coronary artery bypass (ONCAB) surgery without the technical demands of the off-pump (OPCAB) technique. We compared perioperative outcomes and inflammatory mediation among OPCAB, MECC, and ONCAB techniques. We prospectively enrolled 102 patients undergoing elective isolated coronary bypass grafting. Perfusion methods were OPCAB (n = 34), MECC (n = 34), and ONCAB (n = 34). Serial blood samples were collected to measure serum inflammatory markers. There were no operative deaths or strokes. Total red blood cell (RBC) products used in OPCAB, MECC, and ONCAB patients were 0.676, 1.000, and 1.235 units, respectively. Adjusted (by splined Society of Thoracic Surgeons operative risk score) analysis showed no statistically significant differences in mean RBC product use among the different operative systems (OPCAB vs MECC, P = 0.580; OPCAB vs ONCAB, P = 0.311; MECC vs ONCAB, P = 0.633). Adjusted (by Society of Thoracic Surgeons risk score and baseline level) mean plasma level differences (24 hours postoperative - baseline) of C-reactive protein for OPCAB (117.89; 95% confidence interval [95% CI], 106.23-129.54) and for MECC (124.88; 95% CI, 113.45-136.32) were significantly higher than for ONCAB (98.82; 95% CI, 86.40-111.24). No significant adjusted differences (P = 0.304) in interleukin-6 level changes were observed. Off-pump coronary artery bypass and MECC did not significantly reduce mean total RBC transfusion requirements. Off-pump coronary artery bypass and MECC were associated with greater C-reactive protein elevation than ONCAB, suggestive of an increased inflammatory response to each of these techniques.
Masabni, Khalil; Sabik, Joseph F.; Raza, Sajjad; Carnes, Theresa; Koduri, Hemantha; Idrees, Jay J.; Beach, Jocelyn; Riaz, Haris; Shishehbor, Mehdi H.; Gornik, Heather L.; Blackstone, Eugene H.
2016-01-01
Objectives To determine whether nonselective preoperative carotid artery ultrasound screening alters management of patients scheduled for coronary artery bypass grafting (CABG), and whether such screening affects neurologic outcomes. Methods From March 2011 to September 2013, preoperative carotid artery ultrasound screening was performed on 1236 of 1382 patients (89%) scheduled to undergo CABG. Carotid artery stenosis (CAS) was classified as none or mild (any type 0%–59% stenosis), moderate (unilateral 60%-79% stenosis), or severe (bilateral 60%-79% stenosis or unilateral 80%–100% stenosis). Results A total of 1069 (86%) had
Masabni, Khalil; Sabik, Joseph F; Raza, Sajjad; Carnes, Theresa; Koduri, Hemantha; Idrees, Jay J; Beach, Jocelyn; Riaz, Haris; Shishehbor, Mehdi H; Gornik, Heather L; Blackstone, Eugene H
2016-02-01
To determine whether nonselective preoperative carotid artery ultrasound screening alters management of patients scheduled for coronary artery bypass grafting (CABG), and whether such screening affects neurologic outcomes. From March 2011 to September 2013, preoperative carotid artery ultrasound screening was performed on 1236 of 1382 patients (89%) scheduled to undergo CABG. Carotid artery stenosis (CAS) was classified as none or mild (any type 0%-59% stenosis), moderate (unilateral 60%-79% stenosis), or severe (bilateral 60%-79% stenosis or unilateral 80%-100% stenosis). A total of 1069 (86%) had
Bassano, Carlo; Bovio, Emanuele; Uva, Floriano; Iacobelli, Simona; Iasevoli, Nicola; Farinaccio, Andrea; Ruvolo, Giovanni
2016-09-01
Anaortic coronary artery bypass proved to prevent early neurologic injury compared to on-pump CABG. The Cardica PAS-Port(®) is a fully automated device that might be able to perform proximal aorto-venous anastomoses without an increased embolic risk. We evaluated early post-operative neurologic outcome in a matched population following clampless OPCAB (CCAB: either "all-arterial" or with automatically anastomosed venous grafts) or on-pump CABG. 366 consecutive patients were submitted to isolated coronary bypass by a single surgeon experienced in both off and on-pump procedures between January 2009 and December 2013. Of these patients, 223 underwent a clampless off-pump revascularization. After propensity score matching, 143 pairs were selected, who received either off-pump or on-pump surgery. In the off-pump group, CCAB was performed with an all-arterial approach (n = 33) or with automated proximal anastomosis of the venous graft(s) by means of the Cardica PAS-Port(®) connector (n = 110). Neurologic injury was defined as non-reversible (NRNI: lethal coma or stroke) or reversible (RNI: TIA or delirium). Operative mortality was 2.4 % (CCAB 1.4 %; CABG 3.5 %; p = 0.14). The global rate of early neurologic injury was 5.6 % (CCAB 2.1 vs. CABG 9.1 %; p = 0.006). Incidence was 1.4 % for NRNI (CCAB 0 vs. CABG 2.8 %; p = 0.04) and 4.2 % for RNI (CCAB 2.1 vs. CABG 6.3 %; p = 0.06). No differences were found among other major perioperative outcomes. CCAB prevents both early post-operative RNI and NRNI. This result can be achieved with a totally anaortic strategy and also with the aid of a fully automated device for proximal aorto-venous anastomoses.
Early and mid-term results of off-pump endarterectomy of the left anterior descending artery
Takahashi, Mitsuko; Gohil, Sunir; Tong, Bonnie; Lento, Patrick; Filsoufi, Farzan; Reddy, Ramachandra C.
2013-01-01
OBJECTIVES Many patients referred for coronary artery bypass surgery (CABG) today have diffusely diseased coronary vessels, and some of them may require coronary endarterectomy to provide adequate revascularization. Most reports of coronary endarterectomy describe an on-pump procedure. As off-pump coronary artery bypass graft has become safer and more routine, there is renewed interest in off-pump coronary endarterectomy. We report on our series of patients who underwent off-pump coronary endarterectomy of the left anterior descending (LAD) artery using an open endarterectomy technique. METHODS All patients undergoing open heart surgery at The Mount Sinai Medical Center are entered into a state-mandated, audited database. A retrospective review of this database revealed 12 patients between January 2008 and June 2012 who underwent off-pump endarterectomy of the LAD as part of their coronary revascularization. Additional data were collected from a review of the patients' charts. RESULTS There were a total of 12 patients, with a mean age of 72 ± 4 years. Nine (75%) were male and 3 (25%) were female. Comorbidities included hypertension in 11 (92%) patients, dyslipidaemia in 10 (83%), diabetes in 8 (67%), renal failure in 6 (50%) and stroke in 1 (8%). The mean number of diseased coronary territories was 3 ± 0.4 (range 2–3), and the mean number of coronary bypass grafts performed was 4 ± 0.8 (range 2–5). Eight patients required transfusion with packed red blood cells (67%). One (8%) patient was converted from off-pump to on-pump. The mean intensive care unit stay was 3 ± 2.8 (range 1–8 days), and the mean hospital length of stay was 15 ± 13 (range 4–54 days). Postoperative follow-up (mean 24 ± 19 months, range 1–53) is complete, and no ischaemic events have occurred in the early and mid-term follow-up period. CONCLUSIONS We conclude that off-pump endarterectomy of the LAD is a viable option for patients with diffuse LAD disease. PMID:23190620
Benedetto, Umberto; Pecchinenda, Gustavo Guida; Chivasso, Pierpaolo; Bruno, Vito Domenico; Rapetto, Filippo; Bryan, Alan; Angelini, Gianni Davide
2016-01-01
Coronary artery bypass grafting remains the standard treatment for patients with extensive coronary artery disease. Coronary surgery without use of cardiopulmonary bypass avoids the deleterious systemic inflammatory effects of the extracorporeal circuit. However there is an ongoing debate surrounding the clinical outcomes after on-pump versus off-pump coronary artery bypass (ONCAB versus OPCAB) surgery. The current review is based on evidence from randomized controlled trials (RCTs) and meta-analyses of randomized studies. It focuses on operative mortality, mid- and long-term survival, graft patency, completeness of revascularisation, neurologic and neurophysiologic outcomes, perioperative complications and outcomes in the high risk groups. Early and late survival rates for both OPCAB and ONCAB grafting are similar. Some studies suggest early poorer vein graft patency with off-pump when compared with on-pump, comparable midterm arterial conduit patency with no difference in long term venous and arterial graft patency. A recent, pooled analysis of randomised trials shows a reduction in stroke rates with use off-pump techniques. Furthermore, OPCAB grafting seems to reduce postoperative renal dysfunction, bleeding, transfusion requirement and respiratory complications while perioperative myocardial infarction rates are similar to ONCAB grafting. The high risk patient groups seem to benefit from off-pump coronary surgery. PMID:27942394
Chronic Obstructive Pulmonary Disease and Off-Pump Coronary Surgery.
Ovalı, Cengiz; Şahin, Aykut
2018-05-18
To determine to what extent chronic obstructive pulmonary disease (COPD) affects mortality and morbidity rates in patients treated with off-pump coronary artery bypass graft (CABG). A total of 321 patients treated with off-pump CABG were included in the present study. Of the 321 patients, 46 patients had COPD and they were designated as Group 1 and the remaining 275 patients did not have COPD and they were considered as Group 2. We compared the data obtained from the patients in both groups. While preoperative spirometry values and arterial blood gas oxygen saturation levels were significantly lower, the partial values of carbon dioxide were higher in Group 1. Likewise, extubation time, the amount of drainage and blood transfusion, inotropic support, prolonged intubation, pulmonary complications, the use of bronchodilators, and steroids were statistically higher in Group 1 when compared with Group 2. Overall, there was no marked difference between the two groups in terms of mortality incidence. We found similar morbidity and mortality rates among the patients with COPD and without COPD when they were treated with off-pump CABG. Therefore, the present results indicate that the presence of COPD is not associated with in-hospital mortality or severe morbidity post-CABG by off-pump approach.
On- vs. off-pump coronary artery bypass grafting: A systematic review and meta-analysis.
Dieberg, Gudrun; Smart, Neil A; King, Nicola
2016-11-15
To reduce complications during coronary artery bypass grafting (CABG) off-pump CABG was introduced; however, results have been mixed. The aim of this work was to conduct a systematic review and meta-analysis of off-pump vs. on-pump CABG. To identify potential studies systematic searches were carried out using various databases. The search strategy included the key concepts of "cardiopulmonary bypass" AND "coronary artery bypass grafting" AND "off pump". This was followed by a meta-analysis investigating post-operative atrial fibrillation, myocardial infarction, ≤30day mortality, stroke, ventilation time, intensive care unit (ICU) stay and hospital stay. Fifty four studies (59 intervention groups), totalling 16,261 participants were analysed. Off pump CABG led to a significantly lower incidence of post-operative atrial fibrillation odds ratio (OR) 0.87 (95% confidence interval [CI] 0.78 to 0.97, p=0.01), but no differences in either myocardial infarction OR 0.98 (95% CI 0.82 to 1.15, p=0.77) or ≤30day mortality OR 0.85 (95% CI 0.68 to 1.06, p=0.16). There was a strong trend towards a reduced incidence of stroke OR 0.77 (95% CI 0.59 to 1.00, p=0.05); however this did not quite reach significance. Ventilation time mean difference (MD) -3.78h (95% CI -4.75 to -2.82, p<0.00001); ICU stay MD -0.34days (95% CI -0.50 to -0.17, p<0.0001); and hospital stay MD -0.9days (95% CI -1.25 to -0.56, p<0.00001) were all significantly shorter in the off-pump group. Off-pump CABG has some benefits over on-pump CABG, particularly in relation to post-operative atrial fibrillation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pulmonary hemodynamics and gas exchange in off pump coronary artery bypass grafting.
Vedin, Jenny; Jensen, Ulf; Ericsson, Anders; Samuelsson, Sten; Vaage, Jarle
2005-10-01
To investigate the influence of cardiopulmonary bypass on pulmonary hemodynamics and gas exchange. Low risk patients admitted for elective coronary artery bypass grafting were randomized to either on (n=25) or off pump (n=25) surgery. Central hemodynamics, gas exchange, and venous admixture were studied during and up to 20 h after surgery. There was no difference in pulmonary vascular resistance index (P=0.16), right ventricular stroke work index (P>0.2), mean pulmonary artery pressure (P>0.2) or pulmonary capillary wedge pressure (P>0.2) between groups. Soon after surgery there was a tendency towards higher cardiac index (P=0.07) in the off pump group. Arterial oxygen tension (P>0.2), hematocrit (P>0.2), venous admixture (P>0.2), and arterial-venous oxygen content difference (P=0.12) did not differ between groups. This prospective, randomized study showed no difference in pulmonary hemodynamics, pulmonary gas exchange, and venous admixture, in low risk patients undergoing off pump compared to on pump coronary artery bypass surgery.
Lamy, Andre; Devereaux, Philip J; Prabhakaran, Dorairaj; Hu, Shengshou; Piegas, Leopoldo S; Straka, Zbynek; Paolasso, Ernesto; Taggart, David; Lanas, Fernando; Akar, A Ruchan; Jain, Anil; Noiseux, Nicolas; Ou, Yongning; Chrolavicius, Susan; Ng, Jennifer; Yusuf, Salim
2012-01-01
Uncertainty remains regarding the benefits and risks of the technique of operating on a beating heart (off pump) for coronary artery bypass grafting (CABG) surgery versus on-pump CABG. Prior trials had few events and relatively short follow-up. There is a need for a large randomized, controlled trial with long-term follow-up to inform both the short- and long-term impact of the 2 approaches to CABG. We plan to randomize 4,700 patients in whom CABG is planned to undergo the procedure on pump or off pump. The coprimary outcomes are a composite of total mortality, myocardial infarction (MI), stroke, and renal failure at 30 days and a composite of total mortality, MI, stroke, renal failure, and repeat revascularization at 5 years. We will also undertake a cost-effectiveness analysis at 30 days and 5 years after CABG surgery. Other outcomes include neurocognitive dysfunction, recurrence of angina, cardiovascular mortality, blood transfusions, and quality of life. As of May 3, 2011, CORONARY has recruited >3,884 patients from 79 centers in 19 countries. Currently, patient's mean age is 67.6 years, 80.7% are men, 47.0% have a history of diabetes, 51.4% have a history of smoking, and 34.4% had a previous MI. In addition, 20.9% of patients have a left main disease, and 96.6% have double or triple vessel disease. CORONARY is the largest trial yet conducted comparing off-pump CABG to on-pump CABG. Its results will lead to a better understanding of the safety and efficacy of off-pump CABG. Copyright © 2012 Mosby, Inc. All rights reserved.
Off-pump versus on-pump coronary artery revascularization: effects on pulmonary function.
e Silva, Ana M R P; Saad, Roberto; Stirbulov, Roberto; Rivetti, Luiz A
2010-07-01
Many studies have shown important changes in lung function tests after coronary artery surgeries. It is controversial if off-pump surgery can give a better and shorter recovery than the on-pump. A prospective study was conducted on 42 patients submitted to coronary artery surgery and divided into two groups: 21 off-pump using intraluminal shunt (G (I)) and 21 on-pump (G (II)), matched by the anatomical location of the coronary arteries lesions. All patients had spirometric evaluation, blood gas measurements and alveolo-arterial oxygen gradient (A-aDO(2)), at the fourth and 10th postoperative days (PO(4) and PO(10)). Preoperatively, G(I) and G(II) had similar results (P>0.372). Spirometry showed decreases at PO(4) and remained decreased until PO(10) for both groups, with significant differences between the groups. The blood gas measurements showed reduction in arterial oxygen pressure (PaO(2)) and carbon dioxide pressure (PaCO(2)), while there was an increase in A-aDO(2) at PO(4) and PO(10) in both groups. The results suggest that different changes occur in pulmonary function when the surgery is performed with or without cardiopulmonary bypass. The off-pump patients showed significantly greater improvement than the on-pump group.
Caputti, Guido Marco; Palma, José Honório; Gaia, Diego Felipe; Buffolo, Enio
2011-01-01
OBJECTIVES: Patients with coronary artery disease and left ventricular dysfunction have high mortality when kept in clinical treatment. Coronary artery bypass grafting can improve survival and the quality of life. Recently, revascularization without cardiopulmonary bypass has been presented as a viable alternative. The aim of this study is to compare patients with left ventricular ejection fractions of less than 20% who underwent coronary artery bypass graft with or without cardiopulmonary bypass. METHODS: From January 2001 to December 2005, 217 nonrandomized, consecutive, and nonselected patients with an ejection fraction less than or equal to 20% underwent coronary artery bypass graft surgery with (112) or without (off-pump) (105) the use of cardiopulmonary bypass. We studied demographic, operative, and postoperative data. RESULTS: There were no demographic differences between groups. The outcome variables showed similar graft numbers in both groups. Mortality was 12.5% in the cardiopulmonary bypass group and 3.8% in the off-pump group. Postoperative complications were statistically different (cardiopulmonary bypass versus off-pump): total length of hospital stay (days)—11.3 vs. 7.2, length of ICU stay (days)—3.7 vs. 2.1, pulmonary complications—10.7% vs. 2.8%, intubation time (hours)—22 vs. 10, postoperative bleeding (mL)—654 vs. 440, acute renal failure—8.9% vs. 1.9% and left-ventricle ejection fraction before discharge—22% vs. 29%. CONCLUSION: Coronary artery bypass grafting without cardiopulmonary bypass in selected patients with severe left ventricular dysfunction is valid and safe and promotes less mortality and morbidity compared with conventional operations. PMID:22189729
Bu, Xiangmei; Wang, Bo; Wang, Yaoqi; Wang, Zhigang; Gong, Chunzhi; Qi, Feng; Zhang, Caixia
2017-07-01
Off-pump coronary artery bypass graft (CABG) surgery has recently emerged as a means to avoid the sequelae of extracorporeal circulation, including the whole-body inflammatory response, coagulation disorders and multiple organ dysfunction. At present, gas anesthesia, sevoflurane and intravenous anesthesia and propofol have been widely used during the CABG. To further understand the underlying mechanisms of these anesthetics on the gene level, the present study conducted pathway-related module analysis based on a co-expression network. This was performed in order to identify significant pathways in coronary artery disease patients who had undergone off-pump CABG surgery before and after applying sevoflurane or propofol. A total of 269 and 129 differentially expressed genes were obtained in the sevoflurane and propofol groups, respectively. In total, eight and seven pathways (P<0.05) in the sevoflurane and propofol groups were separately obtained via Kyoto Encyclopedia of Genes and Genome pathway analysis. Finally, eight and seven pathway-related modules in the sevoflurane and propofol groups were obtained, respectively. Furthermore, the mean degree of complement and coagulation cascades pathway-related module in both of the groups was the highest. It was predicted that during the CABG, the anesthetics might activate the complement and coagulation systems in order to possess some cardioprotective properties.
Ennker, I C; Pietrowski, D; Ennker, J
2006-01-01
Dextrocardia associated with situs inversus totalis is a rare condition and there are few reports of myocardial revascularisation in such patients. An 82-year-old woman with dextrocardia and situs inversus totalis underwent successful off-pump coronary artery bypass grafting using internal mammary arteries. The operative technique was similar to that of off-pump coronary artery bypass grafting for situs solitus. However, for a right-handed surgeon the operation was easier standing on the left side of the patient.
Formica, Francesco; Broccolo, Francesco; Martino, Antonello; Sciucchetti, Jennifer; Giordano, Vincenzo; Avalli, Leonello; Radaelli, Gianluigi; Ferro, Orazio; Corti, Fabrizio; Cocuzza, Clementina; Paolini, Giovanni
2009-05-01
This prospective randomized study sought to verify the systemic inflammatory response, inflammatory myocardial damage, and early clinical outcome in coronary surgery with the miniaturized extracorporeal circulation system or on the beating heart. Sixty consecutive patients were randomized to miniaturized extracorporeal circulation (n = 30) or off-pump coronary revascularization (off-pump coronary artery bypass grafting, n = 30). Intraoperative and postoperative data were recorded. Plasma levels of interleukin-6 and tumor necrosis factor-alpha were measured from systemic blood intraoperatively, at the end of operation, and 24 and 48 hours thereafter. Levels of the same markers and blood lactate were measured from coronary sinus blood intraoperatively to evaluate myocardial inflammation. Markers of myocardial damage were also analyzed. One patient died in the off-pump coronary artery bypass grafting group. There was no statistical difference in early clinical outcome in both groups. Release of interleukin-6 was higher in the off-pump coronary artery bypass grafting group 24 hours after the operation (P = .03), whereas levels of tumor necrosis factor-alpha were not different in both groups. Cardiac release of interleukin-6, tumor necrosis factor-alpha, and blood lactate were not different in both groups. Release of troponin T was not significantly different in both groups. Levels of creatine kinase mass were statistically higher in the miniaturized extracorporeal circulation group than in the off-pump coronary artery bypass grafting group, but only at the end of the operation (P < .0001). Hemoglobin levels were significantly higher in the miniaturized extracorporeal circulation group than in the off-pump coronary artery bypass grafting group after 24 hours (P = .01). Miniaturized extracorporeal circulation can be considered similar to off-pump surgery in terms of systemic inflammatory response, myocardial inflammation and damage, and early outcome.
Singh, Ashima; Schaff, Hartzell V.; Mori Brooks, Maria; Hlatky, Mark A.; Wisniewski, Stephen R.; Frye, Robert L.; Sako, Edward Y.
2016-01-01
OBJECTIVES Conclusive evidence is lacking regarding the benefits and risks of performing off-pump versus on-pump coronary artery bypass graft (CABG) for patients with diabetes. This study aims to compare clinical outcomes after off-pump and on-pump procedures for patients with diabetes. METHODS The Bypass Angioplasty Revascularization Investigation 2 Diabetes (BARI 2D) trial enrolled patients with type 2 diabetes and documented coronary artery disease, 615 of whom underwent CABG during the trial. The procedural complications, 30-day outcomes, long-term clinical and functional outcomes were compared between the off-pump and on-pump groups overall and within a subset of patients matched on propensity score. RESULTS On-pump CABG was performed in 444 (72%) patients, and off-pump CABG in 171 (28%). The unadjusted 30-day rate of death/myocardial infarction (MI)/stroke was significantly higher after off-pump CABG (7.0 vs 2.9%, P = 0.02) despite fewer complications (10.3 vs 20.7%, P = 0.003). The long-term risk of death [adjusted hazard ratio (aHR): 1.41, P = 0.2197] and major cardiovascular events (death, MI or stroke) (aHR: 1.47, P = 0.1061) did not differ statistically between the off-pump and on-pump patients. Within the propensity-matched sample (153 pairs), patients who underwent off-pump CABG had a higher risk of the composite outcome of death, MI or stroke (aHR: 1.83, P = 0.046); the rates of procedural complications and death did not differ significantly, and there were no significant differences in the functional outcomes. CONCLUSIONS Patients with diabetes had greater risk of major cardiovascular events long-term after off-pump CABG than after on-pump CABG. PMID:25968885
Off-pump supra-arterial myotomy for myocardial bridging.
Crespo, Alejandro; Aramendi, José I; Hamzeh, Gadah; Voces, Roberto
2008-09-01
We report the results of surgery and midterm outcome in two patients with symptomatic myocardial bridging who underwent off-pump supra-arterial myotomy. Both patients were operated upon through a median sternotomy. The anterior wall of the heart was exposed in the same manner as in off-pump CABG. The left anterior descending coronary artery is unroofed from its myocardial bridge with the aid of a heart stabilizer and a blower. Neither heparin nor blood transfusion was required. Both patients survived the operation and are asymptomatic. Postoperative coronary angiogram showed good resolution of the muscle bridge in one patient. We conclude that in symptomatic patients with myocardial bridging despite medical therapy, surgical myotomy can be considered an adequate therapy. It can be safely done off-pump.
Off-pump grafting does not reduce postoperative pulmonary dysfunction.
Izzat, Mohammad Bashar; Almohammad, Farouk; Raslan, Ahmad Fahed
2017-02-01
Objectives Pulmonary dysfunction is a recognized postoperative complication that may be linked to use of cardiopulmonary bypass. The off-pump technique of coronary artery bypass aims to avoid some of the complications that may be related to cardiopulmonary bypass. In this study, we compared the influence of on-pump or off-pump coronary artery bypass on pulmonary gas exchange following routine surgery. Methods Fifty patients (mean age 60.4 ± 8.4 years) with no preexisting lung disease and good left ventricular function undergoing primary coronary artery bypass grafting were prospectively randomized to undergo surgery with or without cardiopulmonary bypass. Alveolar/arterial oxygen pressure gradients were calculated prior to induction of anesthesia while the patients were breathing room air, and repeated postoperatively during mechanical ventilation and after extubation while inspiring 3 specific fractions of oxygen. Results Baseline preoperative arterial blood gases and alveolar/arterial oxygen pressure gradients were similar in both groups. At both postoperative stages, the partial pressure of arterial oxygen and alveolar/arterial oxygen pressure gradients increased with increasing fraction of inspired oxygen, but there were no statistically significant differences between patients who underwent surgery with or without cardiopulmonary bypass, either during ventilation or after extubation. Conclusions Off-pump surgery is not associated with superior pulmonary gas exchange in the early postoperative period following routine coronary artery bypass grafting in patients with good left ventricular function and no preexisting lung disease.
Off-pump surgery: a choice in unstable angina.
Kohli, Vijay; Goel, Mukesh; Sharma, Vijay Kumar; Mishra, Yugal; Malhotra, Rajneesh; Mehta, Yatin; Trehan, Naresh
2003-12-01
The benefit and safety of off-pump coronary artery bypass surgery in patients with unstable angina was assessed retrospectively. From February 1996 to October 2001, 5,306 patients underwent multivessel off-pump coronary artery bypass, of whom 920 (17%) had unstable angina. In these 920 patients, ejection fractions ranged from 15% to 70%, 203 (22%) had an ejection fraction of 20%-35%, and 11 (1%) had an ejection fraction < 20%. Triple-vessel disease was present in 625 patients. Preoperative intraaortic balloon pump support was used in 28 patients. Operative approaches included mid sternotomy (86%), lower partial sternotomy (9%), and left anterior thoracotomy (2%). The number of grafts ranged from 1 to 5 with a mean of 2.43 +/- 0.86, and 92.3% of patients received a left internal mammary artery graft. Twenty-two patients need intraoperative intraaortic balloon pumping. Ten patients (1%) suffered perioperative myocardial infarction. The mean hospital stay was 7.8 +/- 4.3 days. Hospital mortality was 2/920 (0.22%). Intraaortic balloon pumping was helpful in these cases of unstable angina refractory to medical therapy. Off-pump coronary artery surgery was found to be safe and beneficial in these patients.
Stecher, David; Bronkers, Glenn; Noest, Jappe O.T.; Tulleken, Cornelis A.F.; Hoefer, Imo E.; van Herwerden, Lex A.; Pasterkamp, Gerard; Buijsrogge, Marc P.
2014-01-01
To simplify and facilitate beating heart (i.e., off-pump), minimally invasive coronary artery bypass surgery, a new coronary anastomotic connector, the Trinity Clip, is developed based on the excimer laser-assisted nonocclusive anastomosis technique. The Trinity Clip connector enables simplified, sutureless, and nonocclusive connection of the graft to the coronary artery, and an excimer laser catheter laser-punches the opening of the anastomosis. Consequently, owing to the complete nonocclusive anastomosis construction, coronary conditioning (i.e., occluding or shunting) is not necessary, in contrast to the conventional anastomotic technique, hence simplifying the off-pump bypass procedure. Prior to clinical application in coronary artery bypass grafting, the safety and quality of this novel connector will be evaluated in a long-term experimental porcine off-pump coronary artery bypass (OPCAB) study. In this paper, we describe how to evaluate the coronary anastomosis in the porcine OPCAB model using various techniques to assess its quality. Representative results are summarized and visually demonstrated. PMID:25490000
Totally endoscopic sequential arterial coronary artery bypass grafting on the beating heart
Ak, Koray; Wimmer-Greinecker, Gerhard; Dzemali, Omer; Moritz, Anton; Dogan, Selami
2007-01-01
A 50-year-old man was referred to the Department of Thoracic and Cardiovascular Surgery at the Johann Wolfgang-Goethe University (Frankfurt, Germany) with angina on exertion. An evaluation revealed critical stenosis involving the proximal portion of the left anterior descending artery and the first diagonal branch. The patient underwent successful sequential grafting of the left internal mammary artery to the left anterior descending artery and the diagonal branch using a totally endoscopic coronary artery bypass grafting technique on the beating heart with a new version of the da Vinci Surgical System (Intuitive Surgical, USA). To the authors’ knowledge, this is the first report in literature to describe sequential arterial off-pump grafting of two anterior wall target vessels using a totally endoscopic technique on the beating heart. PMID:17440646
A comparison of hybrid coronary revascularization and off-pump coronary revascularization.
Umakanthan, Ramanan; Leacche, Marzia; Gallion, Anna H; Byrne, John G
2013-04-01
Minimally invasive approaches to treat vascular disease have been accruing significant popularity over the last several decades. Due to progressive advances in technology, a variety of techniques are being now utilized in the field of cardiovascular surgery. The objectives of minimally invasive techniques are to curtail operative trauma and minimize perioperative morbidity without decreasing the quality of the treatment. The standard surgical approach for the treatment of coronary artery disease has traditionally been coronary artery bypass grafting surgery via median sternotomy. Off-pump coronary artery bypass grafting surgery offers a less invasive alternative and enables coronary revascularization to be performed without cardiopulmonary bypass. Hybrid coronary revascularization offers an even less invasive option in which minimally invasive direct coronary artery bypass can be combined with percutaneous coronary intervention. In this article, the authors review a recent publication comparing hybrid coronary revascularization and off-pump coronary artery bypass grafting surgery.
Yousif, A; Addison, D; Lakkis, N; Rosengart, T; Virani, S S; Birnbaum, Y; Alam, M
2018-05-01
Data from randomized trials evaluating the efficacy of on- versus off-pump coronary artery bypass grafting remain inconclusive, particularly in high-risk populations. The aim of this study is to compare the outcomes associated with on- versus off-pump coronary artery bypass grafting among high-risk patients. We performed a meta-analysis of randomized control trials comparing on- versus off-pump coronary artery bypass grafting, focusing on high-risk populations. Studies focusing on "high-risk" features: European System of Cardiac Operative Risk Evaluation (EuroSCORE) ≥ 5, age > 70 years, preexisting renal insufficiency, history of stroke(s), and the presence of left ventricular dysfunction were included. MEDLINE, Scopus, and Embase were searched for all publications between January 1, 2000 and August 1, 2016, using the following terms: on-pump, off-pump, coronary artery bypass, high-risk, left ventricular dysfunction, elderly, aged, and renal insufficiency. Endpoints included cardiovascular and all-cause mortality, non-fatal myocardial infarction, stroke, need for revascularization, renal failure, and length of hospital stay. Nine studies incorporating 11,374 patients with a mean age of 70 years were selected. There was no statistical difference in cardiovascular mortality, all-cause mortality, non-fatal myocardial infarction, and renal failure between the two groups. There was a decrease in further revascularization at 1 year with on-pump (OR 0.67 (0.50-0.89)). However, there was an increase in length of hospital stay by 2.24 days (p = 0.03) among the on-pump group with no difference in stroke (OR 1.34 (1.00-1.80)). On-pump is associated with a decreased risk of additional revascularization by 1 year. However, this appears to be a cost of longer hospitalization.
Shim, Jae Kwang; Choi, Yong Seon; Oh, Young Jun; Bang, Sou Ouk; Yoo, Kyung Jong; Kwak, Young Lan
2007-07-01
Preoperative exposure to clopidogrel and aspirin significantly increases postoperative bleeding in patients undergoing on-pump coronary artery bypass graft surgery. Off-pump coronary bypass grafting has been proposed as an alternative technique to attenuate postoperative bleeding associated with clopidogrel. This study aimed to determine the effects of aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in off-pump coronary artery bypass grafting. One hundred six patients scheduled for off-pump coronary artery bypass grafting were divided into three groups: aspirin and clopidogrel discontinued more than 6 days before surgery (group 1, n = 35), aspirin and clopidogrel continued until 3 to 5 days before surgery (group 2, n = 51), and both medications continued within 2 days of surgery (group 3, n = 20). Thromboelastographic tracings were analyzed before induction of anesthesia. Routine coagulation profiles were measured before and after surgery. A cell salvage device was used during surgery and salvaged blood was reinfused. Chest tube drainage and blood transfusion requirement were recorded postoperatively. Patient characteristics, operative data, and thromboelastographic tracings were similar among the groups. There were significant decreases in hematocrit level and platelet count and prolongation in prothrombin time postoperatively in all groups without any intergroup differences. The amounts of perioperative blood loss and blood transfusion required were all similar among the groups. Preoperative clopidogrel and aspirin exposure even within 2 days of surgery does not increase perioperative blood loss and blood transfusion requirements in patients undergoing elective off-pump coronary artery bypass grafting.
A Secure and High-Fidelity Live Animal Model for Off-Pump Coronary Bypass Surgery Training.
Liu, Xiaopeng; Yang, Yan; Meng, Qiang; Sun, Jiakang; Luo, Fuliang; Cui, Yongchun; Zhang, Hong; Zhang, Dong; Tang, Yue
2016-01-01
Existing simulators for off-pump coronary artery (CA) bypass grafting training are unable to provide cardiac surgery residents all necessary skills they need entering the operation room. In this study, we introduced a secure and high-fidelity live animal model to supplement the in vitro simulators for off-pump CA bypass grafting training. The left internal thoracic artery (ITA) of 3 Chinese miniature pigs was grafted to the left anterior descending CA using an end-to-side anastomosis. The free segment of the ITA was fixed on the ventricle surface, making it a simulative CA beating in synchrony with the heart. A total of 6 to 8 training anastomoses were made on each ITA. Animal Experiment Center in Fuwai Hospital. In total, 19 resident surgeons with at least 3 years of cardiac surgery work experience were trained using the new model. Their performances were recorded and reviewed. Simulative coronary arteries were successfully constructed in all 3 animals with no adverse event observed. A total of 19 anastomoses were then completed, 1 pig of 7 anastomoses and the other 2 animals of 6 anastomoses. Time consumption for the anastomosis was 782 ± 107 seconds. Anastomotic leakage was observed in 10/19 procedures. The most frequency site (7/10) was at the toe of the anastomosis. Further, the most common cause was uneven spacing or small margin of the stitches or both. Emergencies occurred during the training process included hypotension (7 procedures), tachyarrhythmia (4 procedures), and low blood oxygen saturation (1 procedure). This study demonstrated the safety and feasibility of our new live pig model in training resident surgeons. The simulative arteries can be easily accomplished and were long enough to place at least 6 anastomoses. Both on lumen diameter and motion status, they were proven to be a good substitution of the CA. Copyright © 2016. Published by Elsevier Inc.
Zhu, Z G; Xiong, W; Ding, J L; Chen, J; Li, Y; Zhou, J L; Xu, J J
2017-03-02
The aim of this study was to analyze if off-pump coronary artery bypass surgery (CABG) is associated with better treatment outcomes in elderly patients (>70 years of age) than on-pump CABG, using meta-analysis. Medline, PubMed, Cochrane and Google Scholar databases were searched until September 13, 2016. Sensitivity and quality assessment were performed. Twenty-two studies, three randomized control trials (RCTs) and 20 non-RCTs were included with 24,127 patients. The risk of death associated with on-pump or off-pump CABG in the RCTs were similar (pooled OR=0.945, 95%CI=0.652 to 1.371, P=0.766). However, in the non-RCTs, mortality risk was lower in patients treated with off-pump CABG than on-pump CABG (pooled OR=0.631, 95%CI=0.587 to 0.944, P=0.003). No differences were observed between the two treatment groups in terms of the occurrence of 30-day post-operative stroke or myocardial infarction (P≥0.147). In the non-RCTs, off-pump CABG treatment was associated with a shorter length of hospital stay (pooled standardized difference in means=-0.401, 95%CI=-0.621 to -0.181, P≤0.001). The meta-analysis with pooled data from non-RCTs, but not RCTs, found that mortality was lower with off-pump compared with on-pump CABG, and suggested that there may be some benefit of off-pump CABG compared with on-pump CABG in the risk of mortality and length of hospital stay.
Saito, Aya; Hirahara, Norimichi; Motomura, Noboru; Miyata, Hiroaki; Takamoto, Shinichi
2018-01-01
Data on isolated coronary artery bypass grafting (CABG) performed in 2013 and 2014, and registered in the Japan Cardiovascular Surgery Database were reviewed for preoperative characteristics, postoperative outcomes, and choice of graft material for the left anterior descending artery (LAD). Isolated CABG was performed off-pump in 54.7% of cases, and graft material for the LAD was left internal thoracic artery in 74.3% and right internal thoracic artery in 15.6%. Operative mortality was 2.0% in elective cases, 8.2% in emergency cases, and 3.0% overall. In elective cases, operative mortality was 1.1% for off-pump CABG compared with 3.0% for on-pump CABG. Clinical results of our isolated CABG were reasonable and acceptable.
Off-pump coronary artery bypass; OPCAB; Beating heart surgery; Bypass surgery - heart; CABG; Coronary artery bypass graft; Coronary artery bypass surgery; Coronary bypass surgery; Coronary artery disease - CABG; CAD - CABG; Angina - ...
Shrestha, M; Bara, C; Khaladj, N; Kamiya, H; Hagl, C; Kallenbach, K; Zhang, R; Klima, U; Haverich, A
2007-09-01
To confirm the quality of total arterial CABG carried out using the left internal thoracic artery (LITA) and a radial artery (RA) T-graft and distal anastomoses immediately in the OR, we developed a new technique using intraoperative graft angiography. A 5-Fr sheath is inserted in the proximal radial artery stump, through which a catheter for LITA angiography is later introduced. From July 2004 to March 2005, 23 patients underwent total arterial CABG with the T-graft and intraoperative graft angiography. On-pump CABG was performed in 22 patients and off-pump CABG in 1 patient. Mean procedure time for the angiography was 13.7 +/- 7.3 minutes, and mean fluoroscopy time was 6.2 +/- 4.6 minutes. In two patients, the RA-marginal artery side-to-side anastomosis was stenosed and had to be revised as demonstrated by graft angiography. In one patient, the RA was kinked and in another, there was a kinking of the LITA. In both cases, kinking was corrected. The remaining anastomoses were seen to have unobstructed flow with no evidence of stenosis. Intraoperative graft angiography can be performed in patients undergoing total arterial CABG. This concept of intraoperative cooperation between an interventional cardiologist and surgeons could significantly improve the operative outcome in CABG surgery.
Hybrid coronary revascularization in the era of drug-eluting stents.
Murphy, Gavin J; Bryan, Alan J; Angelini, Gianni D
2004-11-01
Left internal mammary artery to left anterior descending coronary artery bypass grafting integrated with percutaneous coronary angioplasty (hybrid procedure) offers multivessel revascularization with minimal morbidity in high-risk patients. This is caused in part by the avoidance of cardiopulmonary bypass-related morbidity and manipulation of the aorta coupled with minimally invasive techniques. Hybrid revascularization is currently reserved for particularly high-risk patients or those with favorable anatomic variants however, largely because of the emergence of off-pump coronary artery bypass grafting, which permits more complete multivessel revascularization, with low morbidity in high-risk groups. The wider introduction of hybrid revascularization is limited chiefly by the high number of repeat interventions compared with off-pump coronary artery bypass grafting, which occurs because of the target vessel failure rate of percutaneous coronary intervention. Other demerits are the costs and logistic problems associated with performing two procedures with differing periprocedural management protocols. Recently, drug-eluting stents have reduced the need for repeat intervention after percutaneous coronary intervention, and this has raised the possibility that the results of hybrid revascularization may now equal or even better those of off-pump coronary artery bypass grafting. Although undoubtedly effective at reducing in-stent restenosis, drug-eluting stents will not address the issues of incomplete revascularization or the logistic problems associated with hybrid. Uncertainty regarding the long-term effectiveness of drug-eluting stents in many patients, as well as their high cost when compared with those of off-pump coronary artery bypass grafting surgery, also militates against the wider introduction of hybrid revascularization.
Sá, Michel Pompeu Barros de Oliveira; Ferraz, Paulo Ernando; Escobar, Rodrigo Renda; Martins, Wendell Nunes; Lustosa, Pablo César; Nunes, Eliobas de Oliveira; Vasconcelos, Frederico Pires; Lima, Ricardo Carvalho
2012-12-01
Most recent published meta-analysis of randomized controlled trials (RCTs) showed that off-pump coronary artery bypass graft surgery (CABG) reduces incidence of stroke by 30% compared with on-pump CABG, but showed no difference in other outcomes. New RCTs were published, indicating need of new meta-analysis to investigate pooled results adding these further studies. MEDLINE, EMBASE, CENTRAL/CCTR, SciELO, LILACS, Google Scholar and reference lists of relevant articles were searched for RCTs that compared outcomes (30-day mortality for all-cause, myocardial infarction or stroke) between off-pump versus on-pump CABG until May 2012. The principal summary measures were relative risk (RR) with 95% Confidence Interval (CI) and P values (considered statistically significant when <0.05). The RR's were combined across studies using DerSimonian-Laird random effects weighted model. Meta-analysis and meta-regression were completed using the software Comprehensive Meta-Analysis version 2 (Biostat Inc., Englewood, New Jersey, USA). Forty-seven RCTs were identified and included 13,524 patients (6,758 for off-pump and 6,766 for on-pump CABG). There was no significant difference between off-pump and on-pump CABG groups in RR for 30-day mortality or myocardial infarction, but there was difference about stroke in favor to off-pump CABG (RR 0.793, 95% CI 0.660-0.920, P=0.049). It was observed no important heterogeneity of effects about any outcome, but it was observed publication bias about outcome "stroke". Meta-regression did not demonstrate influence of female gender, number of grafts or age in outcomes. Off-pump CABG reduces the incidence of post-operative stroke by 20.7% and has no substantial effect on mortality or myocardial infarction in comparison to on-pump CABG. Patient gender, number of grafts performed and age do not seem to explain the effect of off-pump CABG on mortality, myocardial infarction or stroke, respectively.
Deppe, Antje-Christin; Arbash, Wasim; Kuhn, Elmar W; Slottosch, Ingo; Scherner, Maximilian; Liakopoulos, Oliver J; Choi, Yeong-Hoon; Wahlers, Thorsten
2016-04-01
In the present systematic review with meta-analysis, we sought to determine the current strength of evidence for or against off-pump and on-pump coronary artery bypass grafting (CABG) with regard to hard clinical end-points, graft patency and cost-effectiveness. We performed a meta-analysis of only randomized controlled trials (RCT) which reported at least one of the desired end-points including: (i) major adverse cardiac and cerebrovascular events (MACCE), (ii) all-cause mortality, (iii) myocardial infarction, (iv) cerebrovascular accident, (v) repeat revascularization, (vi) graft patency and (vii) cost-effectiveness. The pooled treatment effects [odds ratio (OR) or weighted mean difference, 95% confidence intervals (95% CIs)] were assessed using a fixed or random effects model. A total of 16 904 patients from 51 studies were identified after literature search of the major databases using a predefined keyword list. The incidence of MACCE did not differ between the groups, neither during the first 30 days (OR: 0.93; 95% CI: 0.82-1.04) nor for the longest available follow-up (OR: 1.01; 95% CI: 0.92-1.12). While the incidence of mid-term graft failure (OR: 1.37; 95% CI: 1.09-1.72) and the need for repeat revascularization (OR: 1.55; 95% CI: 1.33-1.80) was increased after off-pump surgery, on-pump surgery was associated with an increased occurrence of stroke (OR: 0.74; 95% CI: 0.58-0.95), renal impairment (OR: 0.79; 95% CI: 0.71-0.89) and mediastinitis (OR: 0.44; 95% CI: 0.31-0.62). There was no difference with regard to hard clinical end-points between on- or off-pump surgery, including myocardial infarction or mortality. The present systematic review emphasizes that both off- and on-pump surgery provide excellent and comparable results in patients requiring surgical revascularization. The choice for either strategy should take into account the individual patient profile (comorbidities, life expectancy, etc.) and importantly, the surgeon's experience in performing on- or off-pump CABG in their routine practice. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Kiuchi, Ryuta; Tomita, Shigeyuki; Yamaguchi, Shojiro; Nishida, Yuji; Ohtake, Hiroshi; Nakamura, Hiroyuki; Watanabe, Go
2014-07-01
It is important for coronary active perfusion systems to avoid myocardial ischemia during off-pump coronary artery bypass grafting. We have developed a new concept for a perfusion system to pump blood based on changes in helium gas volume. This system uses a conventional intra-aortic balloon pump to activate the perfusion pump. Our study used basic and animal experiments to investigate the most suitable system for coronary perfusion using this new concept. A conventional intra-aortic balloon pump was used to supply power. A device for perfusion was developed with a balloon placed inside a stiff syringe barrel. The device was connected to the helium gas line of the intra-aortic balloon pump. Changes in flow with changes in augmentation level were noted when volumes outside and within the balloon were changed. Six pigs with occlusion of the left anterior descending artery were used for system validation, with monitoring to identify changes in hemodynamics and cardiac enzyme levels. In the basic experiment, an 80-mL outside volume and 3.0-mL inner volume resulted in the greatest percentage change in flow rate with respect to changes in augmentation. In the animal experiment, the new coronary active perfusion system prevented myocardial ischemia during coronary occlusion. We clarified the most suitable method for our new coronary active perfusion system. Using this system, safe anastomosis was consistently performed in animal experiments. Clinically, off-pump coronary artery bypass may potentially be performed more safely and easily using this new system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Ohira, Suguru; Doi, Kiyoshi; Yaku, Hitoshi
2016-04-05
We describe a simple method to fix the great saphenous vein graft (SVG) to the right coronary artery along the atrioventricular groove using fibrin glue in off-pump coronary artery bypass grafting (OPCAB). After completion of the proximal anastomosis, the SVG was placed along the atrioventricular groove to the acute margin. Fibrin glue was sprayed using pressurized carbon dioxide gas. A distal anastomosis was subsequently performed after rotating the heart to expose the posterior descending artery. It is a straightforward and reproducible technique to determine the optimal length of the SVG and prevent kinking or stretching of the graft, especially in OPCAB.
Nesher, Nahum; Uretzky, Gideon; Insler, Steven; Nataf, Patrick; Frolkis, Inna; Pineau, Emmanuelle; Cantoni, Emmanuel; Bolotin, Gil; Vardi, Moshe; Pevni, Dimitry; Lev-Ran, Oren; Sharony, Ram; Weinbroum, Avi A
2005-06-01
Perioperative hypothermia might be detrimental to the patient undergoing off-pump coronary artery bypass surgery. We assessed the efficacy of the Allon thermoregulation system (MTRE Advanced Technologies Ltd, Or-Akiva, Israel) compared with that of routine thermal care in maintaining normothermia during and after off-pump coronary artery bypass surgery. Patients undergoing off-pump coronary artery bypass surgery were perioperatively and randomly warmed with the 2 techniques (n = 45 per group). Core temperature, hemodynamics, and troponin I, interleukin 6, interleukin 8, and interleukin 10 blood levels were assessed. The mean temperature of the patients in the Allon thermoregulation system group (AT group) was significantly ( P < .005) higher than that of the patients receiving routine thermal care (the RTC group); less than 40% of the latter reached 36 degrees C compared with 100% of the former. The cardiac index was higher and the systemic vascular resistance was lower ( P < .05) by 16% and 25%, respectively, in the individuals in the AT group compared with in the individuals in the RTC group during the 4 postoperative hours. End-of-surgery interleukin 6 levels and 24-hour postoperative troponin I levels were significantly ( P < .01) lower in the patients in the AT group than in the RTC group. The RTC group's troponin levels closely correlated with their interleukin 6 levels at the end of the operation ( R = 0.51, P = .002). Unlike routine thermal care, the Allon thermoregulation system maintains core normothermia in more than 80% of patients undergoing off-pump coronary artery bypass surgery. Normothermia is associated with better cardiac and vascular conditions, a lower cardiac injury rate, and a lower inflammatory response. The close correlation between the increased interleukin 6 and troponin I levels in the routine thermal care group indicates a potential deleterious effect of lowered temperature on the patient's outcome.
Rare case-series of electrocautery burn following off-pump coronary artery bypass grafting
Sabzi, Feridoun; Niazi, Mojtaba; Ahmadi, Alireza
2014-01-01
Abstract: With an increasing number of off-pump coronary artery surgery procedures in high-risk patients with coagulopathy, including renal failure, hepatic failure and anticoagulant drug-using patients, the frequency of related complications such as repeated exploration for bleeding is also increasing. The associated co-morbidity and repeated use of electrocautery in postoperative bleeding leaves patients susceptible to electrocautery ulcers. In this case series, rare cases of cautery burn with unique causative mechanisms are described. PMID:23669602
Early outcomes of on-pump versus off-pump coronary artery bypass grafting.
Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem
2016-01-01
To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher's exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups.
Early outcomes of on-pump versus off-pump coronary artery bypass grafting
Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem
2016-01-01
Objectives: To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. Methods: This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher’s exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Results: Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. Conclusions: At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups. PMID:27648039
Rocco, Isadora Salvador; Viceconte, Marcela; Pauletti, Hayanne Osiro; Matos-Garcia, Bruna Caroline; Marcondi, Natasha Oliveira; Bublitz, Caroline; Bolzan, Douglas William; Moreira, Rita Simone Lopes; Reis, Michel Silva; Hossne, Nelson Américo; Gomes, Walter José; Arena, Ross; Guizilini, Solange
2017-12-26
We aimed to investigate the ability of oxygen uptake kinetics to predict short-term outcomes after off-pump coronary artery bypass grafting. Fifty-two patients aged 60.9 ± 7.8 years waiting for off-pump coronary artery bypass surgery were evaluated. The 6-min walk test distance was performed pre-operatively, while simultaneously using a portable cardiopulmonary testing device. The transition of oxygen uptake kinetics from rest to exercise was recorded to calculate oxygen uptake kinetics fitting a monoexponential regression model. Oxygen uptake at steady state, constant time, and mean response time corrected by work rate were analysed. Short-term clinical outcomes were evaluated during the early post-operative of off-pump coronary artery bypass surgery. Multivariate analysis showed body mass index, surgery time, and mean response time corrected by work rate as independent predictors for short-term outcomes. The optimal mean response time corrected by work rate cut-off to estimate short-term clinical outcomes was 1.51 × 10 -3 min 2 /ml. Patients with slower mean response time corrected by work rate demonstrated higher rates of hypertension, diabetes, EuroSCOREII, left ventricular dysfunction, and impaired 6-min walk test parameters. The per cent-predicted distance threshold of 66% in the pre-operative was associated with delayed oxygen uptake kinetics. Pre-operative oxygen uptake kinetics during 6-min walk test predicts short-term clinical outcomes after off-pump coronary artery bypass surgery. From a clinically applicable perspective, a threshold of 66% of pre-operative predicted 6-min walk test distance indicated slower kinetics, which leads to longer intensive care unit and post-surgery hospital length of stay. Implications for rehabilitation Coronary artery bypass grafting is a treatment aimed to improve expectancy of life and prevent disability due to the disease progression; The use of pre-operative submaximal functional capacity test enabled the identification of patients with high risk of complications, where patients with delayed oxygen uptake kinetics exhibited worse short-term outcomes; Our findings suggest the importance of the rehabilitation in the pre-operative in order to "pre-habilitate" the patients to the surgical procedure; Faster oxygen uptake on-kinetics could be achieved by improving the oxidative capacity of muscles and cardiovascular conditioning through rehabilitation, adding better results following cardiac surgery.
Benefits of off-pump coronary artery bypass grafting in high-risk patients.
Marui, Akira; Okabayashi, Hitoshi; Komiya, Tatsuhiko; Tanaka, Shiro; Furukawa, Yutaka; Kita, Toru; Kimura, Takeshi; Sakata, Ryuzo
2012-09-11
The benefits of off-pump coronary artery bypass graft (OPCAB) compared with conventional on-pump coronary artery bypass graft (CCAB) remain controversial. Thus, it is important to investigate which patient subgroups may benefit the most from OPCAB rather than CCAB. Among the patients undergoing first coronary revascularization enrolled in the CREDO-Kyoto Registry (a registry of first-time percutaneous coronary intervention and coronary artery bypass graft patients in Japan), 2468 patients undergoing coronary artery bypass graft were entered into the study (mean age, 67 ± 9 years). Predicted risk of operative mortality (PROM) of each patient was calculated by logistic EuroSCORE. Patients were divided into tertile based on their PROM. Mortality rates and the incidences of cardiovascular events were compared between CCAB and OPCAB within each PROM tertile using propensity score analysis. A total of 1377 patients received CCAB whereas 1091 received OPCAB. Adjusted 30-day mortality was not significantly different between CCAB and OPCAB patients regardless of their PROM range. However, the odds ratio of 30-day stroke in CCAB compared with OPCAB in the high-risk tertile was 8.30 (95% confidence interval, 2.25-30.7; P<0.01). Regarding long-term outcomes, hazard ratio of stroke in CCAB compared with OPCAB in the high-risk tertile was 1.80 (95% confidence interval, 1.07-3.02; P=0.03). Nevertheless, hazard ratio of overall mortality in the high-risk tertile was 1.44 (95% confidence interval, 0.98-2.11; P=0.06), indicating no statistically significant difference between the 2 procedures. OPCAB as opposed to CCAB is associated with short-term and long-term benefits in stroke prevention in patients at higher risk as estimated by EuroSCORE. No survival benefit of OPCAB was shown regardless of preoperative risk level.
Current outcomes of off-pump coronary artery bypass grafting: evidence from real world practice
2016-01-01
Coronary artery bypass grafting (CABG) can be performed conventionally using cardiopulmonary bypass (CPB) and aortic clamping or on a beating heart (BH) without the use of CPB, the so-called off-pump CABG. Some surgeons, who are proponents of off-pump CABG, preferentially use this technique for the majority of operations, whereas others use it only in certain situations which warrant avoidance of CPB. Ever since the conception of off-pump CABG, the never-ending debate about which technique of CABG is safe and efficacious continues to date. Several randomized controlled trials (RCTs) have been conducted that have either favored on-pump CABG or have failed to show a significant difference in outcomes between the two techniques. However, these RCTs have been fraught with claims that they do not represent the majority of patients undergoing CABG in real world practice. Therefore, assessment of the benefits and drawbacks of each technique through observational and registry studies would be more representative of patients encountered in daily practice. The present review examines various retrospective studies and meta-analyses of observational studies that compare the early and long-term outcomes of off- and on-pump CABG, which assesses their safety and efficacy. Additionally, their outcomes in older patients, females, and those with diabetes mellitus, renal dysfunction, presence of ascending aortic disease, and/or acute coronary syndrome (ACS) have also been discussed separately. The general consensus is that early results of off-pump CABG are comparable to or in some cases better than on-pump CABG. However, on-pump CABG provides a survival benefit in the long term according to a majority of publications in literature. PMID:27942395
Shaefi, Shahzad; Mittel, Aaron; Loberman, Dan; Ramakrishna, Harish
2018-04-04
Surgical coronary artery bypass grafting (CABG) is the standard of care for revascularization of left main or three-vessel coronary artery disease. The off-pump coronary artery bypass graft (OPCAB) procedure avoids the use of cardiopulmonary bypass. Theoretically, OPCAB may improve long-term outcomes by reducing the rates of perioperative myocardial injury, stroke, neurocognitive impairment, and cardiac-related mortality. Several high-quality clinical trials have been conducted since OPCAB became popular in the 1990s and have demonstrated no benefit of OPCAB over traditional CABG with respect to these outcomes despite favorable short-term reductions in transfusion requirements and other postoperative complications. Ultimately, OPCAB is associated with less effective myocardial revascularization and does not entirely prevent complications traditionally associated with cardiopulmonary bypass. This article reviews major high-quality trials of OPCAB versus traditional CABG with respect to both short- and long-term clinical outcomes. Copyright © 2018 Elsevier Inc. All rights reserved.
Kim, Hee Jung; Chung, Jae Eun; Jung, Jae Seung; Kim, In Seup; Son, Ho Sung
2018-05-31
Despite advance in off-pump coronary artery bypass (OPCAB) grafting, there are large debating issues regarding survival benefit between OPCAB and on-pump coronary artery bypass grafting (CABG). The aim of this study is to address appropriateness of OPCAB approach in patients with ischemic heart disease having multiple vessels using South Korea national cohort data. To evaluate the safety and efficacy of OPCAB, we accessed all causes of death, late repeat revascularization, hospitalization for cerebrovascular accident (CVA), and new renal replacement therapy in patients who underwent isolated CABG with multiple grafting (≥2 grafts) and who were registered in the Korean Health Insurance Review and Assessment Service Database between April 2011 and September 2014. OPCAB was performed in 4,692 patients and on-pump CABG in 2,999 patients from 82 hospitals in South Korea. On multivariable analysis, on-pump CABG was associated with a significantly higher adjusted risk of overall all-cause death (hazard ratio [HR]: 1.876, 95% confidence interval [CI]: 1.587-2.216, p < 0.001) and initiation of new renal replacement therapy (HR: 1.618, 95% CI: 1.124-2.331, p = 0.009). However, we observed no significant difference in repeat revascularization and hospitalization for CVA between the two groups. In propensity score matching, matched patients (2,940 pairs) showed results similar to multivariable analysis that on-pump CABG was associated with a higher overall mortality and initiation of new renal replacement therapy ( p < 0.001). In this study, we found that OPCAB was associated with better survival rates and renal preservation compared with on-pump CABG. Georg Thieme Verlag KG Stuttgart · New York.
Yang, Feng; Wang, Jinhong; Hou, Dengbang; Xing, Jialin; Liu, Feng; Xing, Zhi chen; Jiang, Chunjing; Hao, Xing; Du, Zhongtao; Yang, Xiaofang; Zhao, Yanyan; Miao, Na; Jiang, Yu; Dong, Ran; Gu, Chengxiong; Sun, Lizhong; Wang, Hong; Hou, Xiaotong
2016-01-01
Severe left ventricular (LV) dysfunction patients undergoing off-pump coronary artery bypass grafting (OPCAB) are often associated with a higher mortality. The efficacy and safety of the preoperative prophylactic intra-aortic balloon pump (IABP) insertion is not well established. 416 consecutive patients with severe LV dysfunction (ejection fraction ≤35%) undergoing isolated OPCAB were enrolled in a retrospective observational study. 191 patients was enrolled in the IABP group; the remaining 225 patients was in control group. A total of 129 pairs of patients were propensity-score matched. No significant differences in demographic and preoperative risk factors were found between the two groups. The postoperative 30-day mortality occurred more frequently in the control group compared with the IABP group (8.5% vs. 1.6%, p = 0.02). There was a significant reduction of low cardiac output syndrome in the IABP group compared with the control group (14% vs. 6.2%, p = 0.04). Prolonged mechanical ventilation (≥48 h) occurred more frequently in the control group (34.9% vs. 20.9%, p = 0.02). IABP also decreased the postoperative length of stay. Preoperative IABP was associated with a lower 30-day mortality, suggesting that it is effective in patients with severe LV dysfunction undergoing OPCAB. PMID:27279591
Mishra, Manisha; Malhotra, Rajneesh; Mishra, Anil; Meharwal, Zile Singh; Trehan, Naresh
2002-12-01
To evaluate the hemodynamic alterations during off-pump coronary artery bypass graft surgery to determine the degree of impairment caused and the techniques to rectify them. Prospective, observational cohort study performed from January 2000 through September 2000. Patients (n = 500) with coronary artery disease undergoing multivessel off-pump coronary artery bypass graft surgery using the Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, MN). Unstable patients with ongoing ischemia were excluded from the study. All patients were monitored with radial artery and pulmonary artery catheters and continuous transesophageal echocardiography monitoring with a multiplane transducer. The perioperative requirement of an intracoronary shunt, inotropes, or an intra-aortic balloon pump was noted. The effect of the Trendelenburg position and fluids on hemodynamics was observed. The need for defibrillation and institution of emergency cardiopulmonary bypass were major endpoints to determine the inability of the patient to tolerate displacement of the heart. Mean patient age was 59.3 +/- 11.6 years. There were 204 (40%) patients in the high-risk category; 54 (10.8%) patients had left ventricular ejection fraction <25%. The mean number of grafts was 2.7 +/- 0.8. Vertical displacement of the heart to access the lateral and inferior walls decreased the mean arterial pressure by 18 +/- 4% (p < 0.01), with a concomitant increase in central venous pressure of 66 +/- 18% (p < 0.001). The stroke volume and the cardiac index were reduced by 35.7 +/- 11% (p < 0.001) and 45 +/- 13% (p < 0.001). On transesophageal echocardiography, there was development of new regional wall motion abnormalities in 59.2% and a decrease in global left ventricular functions in 61.2%. The use of inotropes was highest during anastomosis on the posterior wall-78.4% compared with 21.9% for the anterior wall. An intra-aortic balloon pump was used in 55 (11.2%) patients, and 7 (0.71 %) patients had to be put on emergency CPB. The in-hospital mortality was 1.2%. Most patients had hemodynamic changes easily correctable by fluids and inotropes. Monitoring of left ventricular and right ventricular function by transesophageal echocardiography enhances safety of the procedure and is recommended. The use of the Octopus II tissue stabilizer proved to be a safe and versatile means to stabilize the heart during off-pump coronary artery bypass procedures, especially in high-risk patients. Copyright 2002, Elsevier Science (USA). All rights reserved.
Cartier, R; Brann, S; Dagenais, F; Martineau, R; Couturier, A
2000-02-01
We sought to report our recent experience with off-pump coronary artery revascularization in multivessel disease. Between October 1996 and December 1998, 300 off-pump beating heart operations were performed at the Montreal Heart Institute by a single surgeon, representing 94% of all procedures undertaken during this same time frame (97% for 1998). This cohort of patients was compared with 1870 patients operated on with cardiopulmonary bypass from 1995 to 1996. Mean age, sex distribution, and preoperative risk factors were comparable for the two groups. On average, 2.92 +/- 0.8 and 2.84 +/- 0.6 grafts per patient were completed in the beating heart and cardiopulmonary bypass groups, respectively. A majority of patients (70%) had either a triple or quadruple bypass. Coronary anastomoses were achieved with myocardial mechanical stabilization and heart "verticalization." Ischemic time was shorter in the beating heart group (29.8 +/- 0.9 vs 45 +/- 0.4 minutes, P <.05). Similarly, the need for transfusion was significantly less in the beating heart group (beating heart operations, 34%; cardiopulmonary bypass, 66%; P <.005). Reduced use of postoperative intra-aortic counterpulsation, as well as a lower rise in creatine kinase MB isoenzyme, was observed in the beating heart group. Operative mortality rates (beating heart operations, 1. 3%; cardiopulmonary bypass, 2%) and perioperative myocardial infarction (beating heart operations, 3.6%; cardiopulmonary bypass, 4.2%) were comparable for the two groups. In a majority of patients, off-pump complete coronary artery revascularization is an acceptable alternative to conventional operations, yielding good results given progressive experience, rigorous technique, and adequate coronary artery stabilization.
Chakravarthy, Murali; Narayan, Sandeep; Govindarajan, Raghav; Jawali, Vivek; Rajeev, Subramanyam
2010-06-01
Partial pressure of carbon dioxide and oxygen were transcutaneously measured in adults after off-pump coronary artery bypass (OPCAB) surgery. The clinical use of such measurements and interchangeability with arterial blood gas measurements for weaning patients from postoperative mechanical ventilation were assessed. This was a prospective observational study. Tertiary referral heart hospital. Postoperative OPCAB surgical patients. Transcutaneous oxygen and carbon dioxide measurements. In this prospective observational study, 32 consecutive adult patients in a tertiary care medical center underwent OPCAB surgery. Noninvasive measurement of respiratory gases was performed during the postoperative period and compared with arterial blood gases. The investigator was blinded to the reports of arterial blood gas studies and weaned patients using a "weaning protocol" based on transcutaneous gas measurement. The number of patients successfully weaned based on transcutaneous measurements and the number of times the weaning process was held up were noted. A total of 212 samples (pairs of arterial and transcutaneous values of oxygen and carbon dioxide) were obtained from 32 patients. Bland-Altman plots and mountain plots were used to analyze the interchangeability of the data. Twenty-five (79%) of the patients were weaned from the ventilator based on transcutaneous gas measurements alone. Transcutaneous carbon dioxide measurements were found to be interchangeable with arterial carbon dioxide during 96% of measurements, versus 79% for oxygen measurements. More than three fourths of the patients were weaned from mechanical ventilation and extubated based on transcutaneous gas values alone after OPCAB surgery. The noninvasive transcutaneous carbon dioxide measurement can be used as a surrogate for arterial carbon dioxide measurement to manage postoperative OPCAB patients. Copyright 2010 Elsevier Inc. All rights reserved.
Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima
2017-10-01
Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes compared to the control group as well as reduces the need for anesthetic compounds. The present study has been registered at the Iranian Registry of Clinical Trials (www.IRCT.IR) with a code of IRCT2016072413159N9 before starting the study. This study was fully sponsored by the Research Deputy at Mashhad University of Medical Sciences, Iran (grant number 941413).
Mechanical support of total cavopulmonary connection with an axial flow pump.
Riemer, R Kirk; Amir, Gabriel; Reichenbach, Steven H; Reinhartz, Olaf
2005-08-01
Even under optimal circumstances, total cavopulmonary connection is associated with a continuous late risk of death. Hemodynamics are distinctly abnormal, with increased systemic venous pressures and frequent low cardiac output. Our study uses a sheep model of total cavopulmonary connection to test the response to axial flow pump (Thoratec HeartMate II; Thoratec Corporation (Pleasanton, Calif)) support of total cavopulmonary connection, which might be suitable to treat patients with failing Fontan circulation. Eight sheep (42-48 kg) were studied. After pilot studies in 3 animals, 5 underwent both pump-supported and nonsupported total cavopulmonary connection in alternating sequence for up to 2 hours. This was achieved with a 12-mm polytetrafluoroethylene graft from the (distally ligated) superior vena cava to the main pulmonary artery and a cannula placed in the inferior vena cava with an attached 16-mm Dacron graft to the main pulmonary artery. Pressures (arterial, inferior vena cava, left atrium, and pulmonary artery) and flows (ascending aorta and inferior vena cava) were recorded over 1 hour both with unsupported total cavopulmonary connection and after placing an axial flow pump (Thoratec HeartMate II) between the inferior vena caval inflow cannula and the main pulmonary artery. Under nonsupported total cavopulmonary connection circulation, inferior vena caval and aortic blood flow decreased by nearly 50%. Inferior vena caval pressure nearly doubled, whereas arterial pressure decreased by one third. Pulmonary artery pressure became nonpulsatile; however, mean pulmonary artery pressure and left atrial pressure did not change significantly. With pump-supported Fontan circulation, cardiac output, inferior vena caval flow, and arterial pressure returned to baseline. Inferior vena caval pressure decreased to below baseline levels. Mean pulmonary artery pressure and left atrial pressure again remained unchanged. Axial flow pump support from the inferior vena cava to the pulmonary artery can prevent the substantial decrease of aortic flow and pressure associated with total cavopulmonary connection and can reverse its poor hemodynamics. This is a simple model that can be used to further evaluate the potential of mechanical support as a treatment option in failing Fontan circulation.
Furukawa, Nobuyuki; Kuss, Oliver; Preindl, Konstantin; Renner, André; Aboud, Anas; Hakim-Meibodi, Kavous; Benzinger, Michael; Pühler, Thomas; Ensminger, Stephan; Fujita, Buntaro; Becker, Tobias; Gummert, Jan F; Börgermann, Jochen
2017-10-01
Meta-analyses from observational and randomized studies have demonstrated benefits of off-pump surgery for hard and surrogate endpoints. In some of them, increased re-revascularization was noted in the off-pump groups, which could impact their long-term survival. Therefore, we analyzed the course of all patients undergoing isolated coronary surgery regarding the major cardiac and cerebrovascular event (MACCE) criteria. A prospective register was taken from a high-volume off-pump center recording all anaortic off-pump (ANA), clampless off-pump (PAS-Port) and conventional (CONV) coronary artery bypass operations between July 2009 and June 2015. Propensity Score Matching was performed based on 28 preoperative risk variables. We identified 935 triplets (N = 2805). Compared with CONV, in-hospital mortality of both the ANA group (OR for ANA [95% CI] 0.25 [0.06; 0.83], P = 0.021), and the PAS-Port group was lower (OR for PAS-Port [95% CI] 0.50 [0.17; 1.32], P = 0.17). In the mid-term follow-up there were no significant differences between the groups regarding mortality (HR for ANA [95%-CI] 0.83 [0.55-1.26], P = 0.38; HR for PAS-Port [95%-CI] 1.06 [0.70-1.59], P = 0.79), incidence of stroke (HR for ANA 0.81 [0.43-1.53], P = 0.52; HR for PAS-Port 0.78 [0.41-1.50], P = 0.46), myocardial infarction (HR for ANA 0.53 [0.22-1.31], P = 0.17; HR for PAS-Port 0.78 [0.37-1.66], P = 0.52) or re-revascularization rate (HR for ANA 0.99 [0.67-1.44], P = 0.94; HR for PAS-Port 0.95 [0.65-1.38], P = 0.77). Both off-pump clampless techniques were associated with lower in-hospital mortality compared with conventional CABG. The mid-term course showed no difference with regard to the MACCE criteria between anaortic off-pump, clampless off-pump using PAS-Port and conventional CABG. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Off-pump compared to minimal extracorporeal circulation surgery in coronary artery bypass grafting.
Reuthebuch, Oliver; Koechlin, Luca; Gahl, Brigitta; Matt, Peter; Schurr, Ulrich; Grapow, Martin; Eckstein, Friedrich
2014-01-01
Coronary artery bypass grafting (CABG) using extracorporeal circulation (ECC) is still the gold standard. However, alternative techniques have been developed to avoid ECC and its potential adverse effects. These encompass minimal extracorporeal circulation (MECC) or off-pump coronary artery bypass grafting (OPCAB). However, the prevailing potential benefits when comparing MECC and OPCABG are not yet clearly established. In this retrospective study we investigated the potential benefits of MECC and OPCABG in 697 patients undergoing CABG. Of these, 555 patients had been operated with MECC and 142 off-pump. The primary endpoint was Troponin T level as an indicator for myocardial damage. Study groups were not significantly different in general. However, patients undergoing OPCABG were significantly older (65.01 years ± 9.5 vs. 69.39 years ± 9.5; p value <0.001) with a higher Logistic EuroSCORE I (4.92% ± 6.5 vs. 5.88% ± 6.8; p value = 0.017). Operating off pump significantly reduced the need for intra-operative blood products (0.7% vs. 8.6%; p-value <0.001) and the length of stay in the intensive care unit (ICU) (2.04 days ± 2.63 vs. 2.76 days ± 2.79; p value <0.001). Regarding other blood values a significant difference could not be found in the adjusted calculations. The combined secondary endpoint, major cardiac or cerebrovascular events (MACCE), was equal in both groups as well. Coronary artery bypass grafting using MECC or OPCABG are two comparable techniques with advantages for OPCABG regarding the reduced need for intra-operative blood products and shorter length of stay in the ICU. However serological values and combined endpoint MACCE did not differ significantly in both groups.
Garg, Amit X; Devereaux, P J; Yusuf, Salim; Cuerden, Meaghan S; Parikh, Chirag R; Coca, Steven G; Walsh, Michael; Novick, Richard; Cook, Richard J; Jain, Anil R; Pan, Xiangbin; Noiseux, Nicolas; Vik, Karel; Stolf, Noedir A; Ritchie, Andrew; Favaloro, Roberto R; Parvathaneni, Sirish; Whitlock, Richard P; Ou, Yongning; Lawrence, Mitzi; Lamy, Andre
2014-06-04
Most acute kidney injury observed in the hospital is defined by sudden mild or moderate increases in the serum creatinine concentration, which may persist for several days. Such acute kidney injury is associated with lower long-term kidney function. However, it has not been demonstrated that an intervention that reduces the risk of such acute kidney injury better preserves long-term kidney function. To characterize the risk of acute kidney injury with an intervention in a randomized clinical trial and to determine if there is a difference between the 2 treatment groups in kidney function 1 year later. The Coronary Artery Bypass Grafting Surgery Off- or On-pump Revascularisation Study (CORONARY) enrolled 4752 patients undergoing first isolated coronary artery bypass graft (CABG) surgery at 79 sites in 19 countries. Patients were randomized to receive CABG surgery either with a beating-heart technique (off-pump) or with cardiopulmonary bypass (on-pump). From January 2010 to November 2011, 2932 patients (from 63 sites in 16 countries) from CORONARY were enrolled into a kidney function substudy to record serum creatinine concentrations during the postoperative period and at 1 year. The last 1-year serum creatinine concentration was recorded on January 18, 2013. Acute kidney injury within 30 days of surgery (≥50% increase in serum creatinine concentration from prerandomization concentration) and loss of kidney function at 1 year (≥20% loss in estimated glomerular filtration rate from prerandomization level). Off-pump (n = 1472) vs on-pump (n = 1460) CABG surgery reduced the risk of acute kidney injury (17.5% vs 20.8%, respectively; relative risk, 0.83 [95% CI, 0.72-0.97], P = .01); however, there was no significant difference between the 2 groups in the loss of kidney function at 1 year (17.1% vs 15.3%, respectively; relative risk, 1.10 [95% CI, 0.95-1.29], P = .23). Results were consistent with multiple alternate continuous and categorical definitions of acute kidney injury or kidney function loss, and in the subgroup with baseline chronic kidney disease. Use of off-pump compared with on-pump CABG surgery reduced the risk of postoperative acute kidney injury, without evidence of better preserved kidney function with off-pump CABG surgery at 1 year. In this setting, an intervention that reduced the risk of mild to moderate acute kidney injury did not alter longer-term kidney function. clinicaltrials.gov Identifier: NCT00463294.
Chakravarthy, Murali; Prabhakumar, Dattatreya; Thimmannagowda, Patil; Krishnamoorthy, Jayaprakash; George, Antony; Jawali, Vivek
2017-01-01
While off pump coronary artery bypass surgery is practiced with an intention to reduce the morbidity associated with cardiopulmonary bypass, the resultant 'hypercoagulability' needs to be addressed. Complications such as cavitary thrombus possibly due to the hyper coagulability after off pump coronary artery bypass surgery have been described. Many clinicians use higher doses of heparin - up to 5 mg/kg in order to thwart this fear. Overall, there appears to be no consensus on the dose of heparin in off pump coronary artery bypass surgeries. The aim of the study was understand the differences in outcome of such as transfusion requirement, myocardial ischemia, and morbidity when two different doses were used for systemic heparinization. Elective patients scheduled for off pump coronary artery bypass surgery were included. Ongoing anti platelet medication was not an exclusion criteria, however, anti platelet medications were ceased about a week prior to surgery when possible. Thoracic epidural anesthesia was administered as an adjunct in patients who qualified for it. By computer generated randomization chart, patients were chosen to receive either 2 or 3 mg/kg of intravenous unfractioned heparin to achieve systemic heparinization with activated clotting time targeted at >240 secs. Intraoperative blood loss, postoperative blood loss, myocardial ischemic episodes, requirement of intraaortic balloon counter pulsation and transfusion requirement were analyzed. Sixty two patients participated in the study. There was one conversion to cardiopulmonary bypass. The groups had comparable ACT at baseline (138.8 vs. 146.64 seconds, P = 0.12); 3 mg/kg group had significantly higher values after heparin, as expected. But after reversal with protamine, ACT and need for additional protamine was similar among the groups. Intraoperative (685.56 ± 241.42 ml vs. 675.15 ± 251.86 ml, P = 0.82) and postoperative blood loss (1906.29 ± 611.87 ml vs 1793.65 ± 663.54 ml , p value 0.49) were similar among the groups [Table 4]. The incidence of ECG changes of ischemia, arrhythmias, conversion to CPB, or need for intra-aortic balloon counter pulsation were not different. Use of either 2 or 3 mg/kg heparin for systemic heparinization in patients undergoing OPCAB did not affect the outcome.
Risk Factors of On-Pump Conversion during Off-Pump Coronary Artery Bypass Graft
Yoon, Sung Sil; Bang, Jung Hee; Jeong, Sang Seok; Jeong, Jae Hwa; Woo, Jong Soo
2017-01-01
Background Off-pump coronary artery bypass grafting (OPCABG) procedures can avoid the complications of an on-pump bypass. However, some cases unexpectedly require conversion to cardiopulmonary bypass during OPCABG. The risk factors associated with a sudden need for cardiopulmonary bypass were analyzed. Methods This retrospective study included 283 subjects scheduled for OPCABG from 2001 to 2010. These were divided into an OPCABG group and an on-pump conversion group. Preoperative, operative, and postoperative variables were compared between the 2 groups. Results Of the 283 patients scheduled for OPCABG, 47 (16%) were switched to on-pump coronary artery bypass grafting (CABG). The mortality of the both the OPCABG and on-pump conversion groups was not significantly different. The major risk factors for conversion to on-pump CABG were congestive heart failure (CHF) (odds ratio [OR], 3.5; p=0.029), ejection fraction (EF) <35% (OR, 4.4; p=0.012), and preoperative beta-blocker (BB) administration (OR, 0.3; p=0.007). The use of intraoperative (p=0.007) and postoperative (p=0.021) inotropics was significantly higher in the conversion group. The amount of postoperative drainage (p<0.001) and transfusion (p<0.001) also was significantly higher in the conversion group. There were no significant differences in stroke or cardiovascular complications between the groups over the course of short-term and long-term follow-up. Conclusion Patients who undergo OPCABG and have CHF or a lower EF (<35%) are more likely to undergo on-pump conversion, while preoperative BB administration could help prevent conversions from OPCABG to on-pump CABG. PMID:29124027
[Coronary revascularization in patients with preoperative electrical storm].
Kawashima, Toshiya; Naraoka, S
2007-03-01
We report 5 cases who underwent surgical coronary revascularization for subacute myocardial ischemia with preoperative electrical storm. All patients showed severe left ventricular dysfunction. Mean ejection fraction was 24.4 +/- 7.6%. Three patients had already had implantable cardioverter-defibrillator (ICD) therapy. Procedures were on-pump coronary artery bypass grafting (CABG) and mitral valvuloplasty (MVP) [case 1], on-pump CABG, MVP, left ventricular restoration (LVR) and cryoablation (case 2), and off-pump CABG (case 3-5). Case 5 necessitated conversion to on-pump for electrical storm during left circumflex artery (LCx) anastomosis. Case 3 suddenly died on the 2nd postoperative day due to electrical storm. Case 1 had recurrent attack of electrical storm postoperatively, treated by ICD, overdrive pacing, repeated intraaortic balloon pumping (IABP), deep sedation with endotracheal intubation, and finally catheter ablation. Four patients have survived 2 years (mean) postoperatively without any arrhythmia, and are all in good condition [New York Heart Association (NYHA) I] now. It was concluded that off-pump procedure was not suitable for subacute myocardial ischemia with electrical storm and that LVR with surgical cryoablation would be effective if indicated.
The impact of hybrid coronary revascularization on hospital costs and reimbursements.
Halkos, Michael E; Ford, Lauren; Peterson, Dane; Bluestein, Sheryl M; Liberman, Henry A; Kilgo, Patrick; Puskas, John D; Guyton, Robert A; Chowdhury, Ritam
2014-05-01
Hybrid coronary revascularization (HCR) combines a minimally invasive, left internal mammary artery-left anterior descending coronary artery (LAD) bypass with percutaneous intervention of non-LAD vessels for patients with multivessel coronary disease. The financial implications of HCR have not been compared with off-pump coronary artery bypass (OPCAB) through sternotomy. The contribution margin is a fiduciary calculation (best hospital payment estimate--total variable costs) used by hospitals to determine fiscal viability of services. From 2010 to 2011, 26 Medicare patients underwent HCR at a single United States institution and were compared with 28 randomly selected, contemporaneous Medicare patients undergoing multivessel OPCAB. All HCR patients underwent a robotic-assisted, sternal-sparing, off-pump, left internal mammary artery-LAD anastomosis plus percutaneous intervention to non-LAD vessels. A linear regression model was used to compare fiscal and utilization outcomes of HCR to OPCAB adjusted for hospital length of stay and The Society of Thoracic Surgeons Predicted Risk of Mortality score. On regression analysis controlling for overall length of stay and Predicted Risk of Mortality score, the contribution margin (+$8,771, p<0.0001) was greater for HCR than for OPCAB. Despite higher total cost for HCR compared with OPCAB (+$7,026, p=0.001), the total variable cost (+$2,281, p=0.07) was not significantly different. Best payment estimates (+11,031, p<0.0001) and Medicare reimbursements (+$8,992, p=0.002) were higher for HCR than for OPCAB, and there was a reduction in blood transfusion (-1.5 units, p<0.0001), ventilator time (-10 hours, p=0.001), and postoperative length of stay (-1.2 days, p=0.002) for the HCR group. Compared with OPCAB, HCR results in a greater contribution margin for hospitals. This may result from higher reimbursement as well as improved resource utilization postoperatively, which may offset more expensive procedural costs associated with HCR. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Jongman, Rianne M; Zijlstra, Jan G; Kok, Wendelinde F; van Harten, Annemarie E; Mariani, Massimo A; Moser, Jill; Struys, Michel M R F; Absalom, Anthony R; Molema, Grietje; Scheeren, Thomas W L; van Meurs, Matijs
2014-08-01
Coronary artery bypass graft (CABG) surgery can result in severe postoperative organ failure. During CABG surgery, cardiopulmonary bypass (CPB) with cardiac arrest is often used (on-pump CABG), which often results in a systemic inflammatory response. To reduce this inflammatory response, off-pump CABG was reintroduced, thereby avoiding CPB. There is increasing evidence that the endothelium plays an important role in the pathophysiology of organ failure after CABG surgery. In this study, 60 patients who were scheduled for elective CABG surgery were randomized to have surgery for on-pump or off-pump CABG. Blood was collected at four time points: start, end, 6 h, and 24 h postoperatively. Levels of inflammatory cytokines, soluble adhesion molecules, and angiogenic factors and their receptors were measured in the plasma. No differences were found in preoperative characteristics between the patient groups. The levels of tumor necrosis factor-α, interleukin 10, and myeloperoxidase, but not interleukin 6, were increased to a greater extent in the on-pump CABG compared with off-pump CABG after sternum closure. The soluble endothelial adhesion molecules E-selectin, vascular cell adhesion molecule 1, and intracellular adhesion molecule 1 were not elevated in the plasma during and after CABG surgery in both on-pump and off-pump CABG. Angiopoietin 2 was only increased 24 h after surgery in both on-pump and off-pump CABG. Higher levels of sFlt-1 were found after sternum closure in off-pump CABG compared with on-pump CABG. Avoiding CPB and aortic cross clamping in CABG surgery reduces the systemic inflammatory response. On-pump CABG does not lead to an increased release of soluble endothelial adhesion molecules in the circulation compared with off-pump CABG.
Bangash, Sohail Khan; Pathan, Iqbal Hussain; Zaki, Saad Bader
2016-10-01
A heart with two atriums but one ventricle, an anatomy with a unique physiology, is responsible for many creative surgical and interventional approaches in history. Different surgical techniques have been used to address this strange physiology of parallel circulation. All these attempts met with failure till the concept of Fontan circulation was described. Currently, controversy exists between multistage vs. single stage total cavopulmonary connections. Total cavopulmonary connection is the only definitive procedure performed to provide palliation for patients with complex congenital heart defects which cannot support a biventricular circulation. We report a case with tricuspid atresia with transposition of great arteries and pulmonary stenosis with persistant left-sided superior vena cava and functionally single ventricle. Patient successfully underwent single stage extra-cardiac total cavopulmonary connection. In this case, bilateral Glenn with extra-cardiac inferior vena cava to main pulmonary artery shunt was performed off-pump.
Soltani, Ghasem; Jahanbakhsh, Saeed; Tashnizi, Mohammad Abbasi; Fathi, Mehdi; Amini, Shahram; Zirak, Nahid; Sheybani, Shima
2017-01-01
Background Arrhythmia occurring during and after surgery is one of the major complications in open-heart surgery. Dexmedetomidine is an intravenous alpha-2 agonist and very specific short-acting drug to protect the various organs against ischemic injuries and blood reflow. However, the effect of dexmedetomidine for preventing intraoperative heart arrhythmias has not been recognized. Objective This study aimed to determine the effect of dexmedetomidine on the incidence rate of heart arrhythmias and anesthetic required in off-pump coronary artery bypass surgery. Methods This randomized clinical trial was conducted on patients who were candidates for off-pump coronary artery bypass referring to Imam Reza Hospital of Mashhad, Iran, from July 2016 through January 2017. The patients were randomly assigned to two groups of intervention (infusion of 0.5 mcg/kg/h dexmedetomidine together with induction followed by infusion of 0.5 mcg/kg/h by the end of the surgery) or control (saline infusion). Mean arterial pressure (MAP) and heart rate (HR) were measured before induction, during surgery operation and ICU admission. Data were analyzed by SPSS version 18 using Chi Square and independent-samples t-test. Results A total of 76 patients with a mean age of 59.8 ± 8.2 years (in two groups of 38) were studied. The two groups had no statistically significant difference in terms of background variables. The MAP and HR values before induction, during surgery and ICU admission were significantly higher in the control group than in the intervention group (p=0.001). Out of the studied arrhythmias, the values of PAC (55.2% vs. 15.7%), PVC (81.5% vs. 21.0%), AF (26.3% vs. 7.8%), VTAC (21.0% vs. 2.6%) were significantly lower in dexmedetomidine group (p=0.001). Conclusion It seems that dexmedetomidine administration during induction and surgery can cause significant reduction in most of the common arrhythmias in off-pump coronary bypass surgery. The use of dexmedetomidine maintains MAP and HR at significantly lower values, and changes compared to the control group as well as reduces the need for anesthetic compounds. Trial Registration The present study has been registered at the Iranian Registry of Clinical Trials (www.IRCT.IR) with a code of IRCT2016072413159N9 before starting the study. Founding This study was fully sponsored by the Research Deputy at Mashhad University of Medical Sciences, Iran (grant number 941413). PMID:29238500
Kalisnik, Jurij M; Avbelj, Viktor; Trobec, Roman; Ivaskovic, Daroslav; Vidmar, Gaj; Troise, Giovanni; Gersak, Borut
2006-01-01
Altered autonomic regulation precipitates cardiac arrhythmias and increases the risk of sudden cardiac death. This risk is further increased by changes in ventricular repolarization. Autonomic regulation is deranged in patients after myocardial on-pump revascularization. We aimed to clarify how off-pump coronary artery bypass grafting (CABG) affects postoperative cardiac autonomic regulation and ventricular repolarization within 4 weeks after CABG. Forty-two patients (mean age, 61.9 +/- 9.3 years; mean EURO score 2.6 +/- 1.9) were electively admitted for off-pump CABG. The electrocardiographic and respiratory waveform recordings were performed in the afternoon in the supine position for 10 minutes. Autonomic modulation was assessed using heart rate variability analysis. Power spectra were computed from 5-minute stable RR intervals using Fourier Transform analysis. Total power of spectra was defined in the range of 0.01 to 0.40 Hz, high-frequency power within 0.15 to 0.40 Hz, and low-frequency power within 0.04 to 0.15 Hz. Normalized power was defined as a ratio of power in each band/total power. The high- and low-frequency power as well as their normalized values indicated cardiac vagal and sympathetic modulation, respectively. Ventricular repolarization was assessed using QT interval, QT interval variability, and QT-RR interdependence analysis. QT intervals were determined from the beginning of the 5-minute segments. QT interval variability was evaluated by a T-wave template-matching algorithm. Pearson correlation between length of RR and QT interval was applied to study QT-RR characteristics. The results were tested for significance using the Fisher exact test, nonpaired t test, and analysis of variance; a P <.05 was considered significant. The frequency of arrhythmic events and heart rate increased from the fourth to the seventh postoperative day and returned to preoperative levels 4 weeks after CABG. Heart rate variability measures indicating autonomic modulation remained depressed even 4 weeks after the procedure. QT variability index increased from -1.2 +/- 0.5 to -0.8 +/- 0.4 on the fourth day after the operation (P <.05) and returned to -1.0 +/- 0.5 4 weeks after CABG (P = not significant). QT-RR correlation decreased from 0.41 to 0.23 (P <.05) and remained significantly impaired as long as 4 weeks after CABG. Observed faster heart rates until 1 week after off-pump CABG imply excessive adrenergic activation, which is comparable to on-pump CABG procedure rates. The results indicate profound autonomic derangement and loss of rate-dependent regulation after off-pump CABG even 4 weeks after operation. Restituted repolarization as assessed by QT variability index 4 weeks postoperatively corresponded with decreased frequency of rhythm disturbances 4 weeks after CABG. The loss of coupling between QT and RR intervals shows increased electrical instability postoperatively, which may serve as an additional promoter for postoperative arrhythmias, especially at higher heart rates.
Espinoza, Andreas; Bergsland, Jacob; Lundblad, Runar; Fosse, Erik
2012-01-01
The internal mammary artery (IMA) is routinely used for grafting of the left anterior descending coronary artery (LAD), providing good flow to the anterior left ventricle (LV) wall. Impeded IMA-to-LAD flow may result in myocardial ischaemia and haemodynamic deterioration. From a study population, we describe two incidents where myocardial ischaemia was observed during off-pump coronary artery bypass surgery (CABG), with a confirmed reduction in the IMA-to-LAD flow in one patient. In patient no. 1, normal IMA flow was assessed by transit-time flow measurement after a complete IMA-to-LAD anastomosis. The anterior LV wall thickening was monitored continuously by epicardial ultrasonic transducers. Normal wall thickening was confirmed after IMA grafting. During a wide sternal opening for circumflex grafting the anterior wall motion displayed an ischaemic pattern, with reduced systolic and increased post-systolic wall thickening. IMA flow was reduced simultaneously. When easing the sternal opening, IMA flow normalized, as did the motion pattern in the anterior LV wall. In patient no. 2, similar changes in wall thickening occurred during a wide sternal opening after IMA-to-LAD grafting. When easing the retractor, the wall thickening normalized. It is important for the surgeon to be aware of this possible cause of myocardial ischaemia, with a risk of subsequent haemodynamic deterioration. This may not only be of great importance during off-pump CABG, but can also be significant for successful weaning from the cardiopulmonary bypass machine. PMID:22499803
Fot, Evgenia V; Izotova, Natalia N; Yudina, Anjelika S; Smetkin, Aleksei A; Kuzkov, Vsevolod V; Kirov, Mikhail Y
2017-01-01
The early warning scores may increase the safety of perioperative period. The objective of this study was to assess the diagnostic and predictive role of Integrated Pulmonary Index (IPI) after off-pump coronary artery bypass grafting (OPCAB). Forty adult patients undergoing elective OPCAB were enrolled into a single-center prospective observational study. We assessed respiratory function using IPI that includes oxygen saturation, end-tidal CO 2 , respiratory rate, and pulse rate. In addition, we evaluated blood gas analyses and hemodynamics, including ECG, invasive arterial pressure, and cardiac index. The measurements were performed after transfer to the intensive care unit, after spontaneous breathing trial and at 2, 6, 12, and 18 h after extubation. The value of IPI registered during respiratory support correlated weakly with cardiac index (rho = 0.4; p = 0.04) and ScvO 2 (rho = 0.4, p = 0.02). After extubation, IPI values decreased significantly, achieving a minimum by 18 h. The IPI value ≤9 at 6 h after extubation was a predictor of complicated early postoperative period (AUC = 0.71; p = 0.04) observed in 13 patients. In off-pump coronary surgery, the IPI decreases significantly after tracheal extubation and may predict postoperative complications.
Giant pseudoaneurysm from Vieussens' arterial ring.
Kocica, Mladen J; Vranes, Mile R; Djukic, Petar L; Mikic, Aleksandar Dj; Velinovic, Milos M; Havelka, Marija; Kanjuh, Vladimir I
2004-11-01
A giant coronary pseudoaneurysm of uncertain cause, arising from Vieussens' arterial ring, was preoperatively diagnosed in an oligosymptomatic female patient. Successful off-pump surgical excision without additional bypass grafting was performed. Difficulties in diagnostic algorithm, as well as possible cause and extremely rare localization were discussed.
Kato, Tomoko S; Machida, Yoichiro; Kuwaki, Kenji; Yamamoto, Taira; Amano, Atsushi
2017-02-01
Cardiopulmonary bypass usage provokes a systemic inflammatory response resulting in deterioration of renal function. However, risk factors for requiring renal replacement therapy (RRT) following off-pump coronary artery bypass graft surgery (CABG) have not yet been fully elucidated. We reviewed 718 consecutive patients undergoing elective off-pump CABG at our institution, excluding patients on chronic hemodialysis preoperatively. Sub-analysis of patients with preserved renal function, defined as a creatinine level below a cut-off value of 1.12 mg/dL (obtained by receiver operating characteristic curve), was also performed. Of the 718 patients, 41 (5.7 %) required RRT. There were 556 patients (77.4 %) with preserved renal function preoperatively, and 13 (2.4 %) of these required postoperative RRT. Multivariate analysis revealed that age (years) and preoperative serum creatinine (mg/dL) and brain natriuretic peptide (BNP) levels (pg/dL) were associated with RRT [odds ratios (OR) 1.052, 95 % confidence interval (CI) 9.064 and 1.001, respectively, all p < 0.05] in the total population, whereas low albumin concentration was the only independent predictor for RRT in patients with preserved renal function (OR 0.062, p < 0.0001). When creatinine levels were below 1.5 mg/dL, the predictive power of hypoalbuminemia for RRT requirement overwhelmed that of creatinine or BNP levels. Older age, preoperative elevated creatinine and BNP levels were associated with a requirement for RRT following off-pump CABG. In patients with preserved renal function, hypoalbuminemia was most significantly related to the RRT requirement.
Chaudhry, Umar A R; Rao, Christopher; Harling, Leanne; Athanasiou, Thanos
2014-07-01
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether off-pump coronary artery bypass grafting (CABG) surgery offered superior long-term outcomes compared with on-pump CABG surgery. Best evidence papers were considered to be those that had a follow-up period of ≥5 years, had >50 patients in either cohort, did not utilize concomitant interventions nor comprised low-risk, high-risk or sub-population groups. Where potential duplicate data sets from the same institution were likely, the more credible and recently published study was included. Two hundred and fifty-six papers were found as a result of the reported search, of which 16 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The 16 studies comprised 4 prospective randomized controlled trials (RCTs), with the remaining 12 retrospective, of which 8 were propensity-score matched. All 4 RCTs contained fewer than 450 participants. Two studies concluded with a survival advantage towards on-pump CABG: one, a large registry-based study, the Veterans Affairs, with >25 000 patients, and another, a propensity-matched retrospective study involving almost 8000 patients. The remaining 14 studies all provided evidence to suggest comparable long-term survival. In addition, all other long-term outcomes mentioned within these studies including angina recurrence, myocardial infarction heart failure, need for revascularization, stroke, graft patency, cognitive and quality of life showed similar results between the two groups. We conclude that off-pump CABG surgery may have similar or slightly reduced long-term survival compared with on-pump CABG surgery. Other long-term indicators such as cardiovascular or cerebrovascular events or neuro-psychological outcomes were similar between the two groups. Despite these conclusions, the evidence is limited by substantial variability in patient selection and study methods. The CORONARY (coronary artery bypass surgery off- or on-pump revascularization study) trial recently presented results, which showed no significant differences in composite outcomes at 1 year; it will be interesting to observe whether these comparable outcomes are maintained for a much longer time frame. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Microemboli in our bypass circuits: a contemporary audit.
Willcox, Timothy W; Mitchell, Simon J
2009-12-01
Cardiopulmonary bypass (CPB) may introduce microemboli into the patient's arterial circulation. These may arise from the CPB circuit. Most relevant studies have been performed in vitro; there are relatively few clinical studies. We used the Emboli Detection and Classification quantifier (EDAC) (Luna Innovations, Roanoke, VA) in a prospective clinical audit of emboli in a contemporary CPB circuit. Following ethics approval, standard clinical CPB circuits in patients undergoing CPB were instrumented with three EDAC system probes placed on the venous line, outlet of the hard-shell venous reservoir (HSVR), and distal to the arterial line filter. This was synchronized with the perfusion data management system and emboli number and volume were recorded at 30-second intervals. Recorded observations and combined data from both the EDAC and data management system were analyzed. We report data from the first 12 patients (24.5 hours of CPB) of a larger series currently being performed. The mean total emboli count per minute was significantly greater downstream of the HSVR than in the venous line and significantly less downstream of the arterial line filter than either of the above. The total count downstream of both the HSVR and the arterial line filter was greater when the vent pump was on vs. off. Despite the significant increase in emboli count downstream of the reservoir during vent operation there was a significant reduction in the total volume of emboli in this position compared with the venous line. This was further reduced by the arterial line filter. Nevertheless, the total embolic volume was greater downstream of the HSVR and the arterial filter with the vent on vs. off. The two overwhelming sources of emboli emanating from our CPB circuit were the use of the left ventricular vent and air entrained from the venous line. Such audit enables refinement of CPB management and potential component redesign which may make CPB safer and improve patient outcome.
2013-01-01
Background Coronary artery bypass grafting (CABG) on cardiopulmonary bypass (CBP) is associated with significant morbidity and mortality. In high-risk patients, doomed for reoperation the adverse effects of CBP may be more striking. We evaluated the results of reoperative CABG (redo-CABG) by either off-pump (OPCAB) or on-pump (ONCAB). Clinical endpoints were perioperative myocardial infarction, mortality, survival and as the most striking difference between prior studies the quality of life (QoL). Methods We performed a prospective, non-randomized assessment for patients who underwent redo-CABG by redo-OPCAB (n = 40) or redo-ONCAB (n = 40) at our institution between January 2007 and December 2010. For evaluation of QoL the SF-36 health survey was used with self-administered assessment. Results During follow-up 37 of 40 patients were alive in the redo-OPCAB group versus 32 of 40 patients in the redo-ONCAB group (p < 0.05). The shorter operation time, less blood loss, fewer perioperative myocardial infarctions, the higher rate of totally arterial revascularisation and shorter intensive care stay were the significantly beneficial differences for patients in the redo-OPCAB group (p < 0.05). The 3-year survival rate was higher in the redo-OPCAB group with 81 ± 12% versus 63 ± 9%in the redo-ONCAB group. The quality of life survey did not reveal any significant differences between both groups. Conclusion In conclusion, with our present retrospective study, we could demonstrate the safety and efficacy of the redo-OPCAB technique with even higher 3-year survival rate. Both techniques seem to have similar impact on the outcome of patients. PMID:23561396
Mannacio, Vito; Meier, Pascal; Antignano, Anita; Di Tommaso, Luigi; De Amicis, Vincenzo; Vosa, Carlo
2014-10-01
An increasing number of patients presenting for urgent coronary surgery have been exposed to clopidogrel, which constitutes a risk of bleeding and related events. Based on the wide variability in clopidogrel response and platelet function recovery after cessation, we evaluated the role of point-of-care platelet function testing to define the optimal time for off-pump coronary artery bypass graft (CABG) surgery in a case-control study. Three equally matched groups (300 patients in total) undergoing isolated off-pump CABG for acute coronary syndrome were compared. Group A were treated with clopidogrel and prospectively underwent a strategy guided by platelet function testing. Outcomes were compared with 2 propensity score matched groups: group B underwent CABG after the currently recommended 5 days without clopidogrel; group C were never exposed to clopidogrel. Patients in group A had reduced postoperative bleeding compared with those in group B (523±202 mL vs 851±605 mL; P<.001) and a lower number of units packed red blood cells (PRBCs) transfused during the postoperative hospital stay (1.2±1.6 units vs 1.9±1.8 units; P=.004). Postoperative bleeding and the number of units of PRBCs transfused were similar in group A and group C. There was no difference in blood-derived products and platelet consumption, mortality, or the need for reoperation among the groups. Patients in group A waited 3.6±1.7 days for surgery. The strategy used for group A saved 280 days of hospital stay in total. The strategy guided by platelet function testing for off-pump CABG offers improved guidance for optimal timing of CABG in patients treated with clopidogrel. This strategy significantly reduces postoperative bleeding and blood consumption, and has a shorter waiting time for surgery than current clinical practice. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Caruso, Maria Vittoria; Gramigna, Vera; Renzulli, Attilio; Fragomeni, Gionata
2016-01-01
The extracorporeal membrane oxygenation (ECMO) is a temporary, but prolonged circulatory support for cardiopulmonary failure. Clinical evidence suggests that pulsed flow is healthier than non pulsatile perfusion. The aim of this study was to computationally evaluate the effects of total and partial ECMO assistance and pulsed flow on hemodynamics in a patient-specific aorta model. The pulsatility was obtained by means of the intra-aortic balloon pump (IABP), and two different cases were investigated, considering a cardiac output (CO) of 5 L/min: Case A - total assistance - the whole flow delivered through the ECMO arterial cannula; Case B - partial assistance - flow delivered half through the cannula and half through the aorta. Computational fluid dynamic (CFD) analysis was carried out using the multiscale approach to couple the 3D aorta model with the lumped parameter model (resistance boundary condition). In case A pulsatility followed the balloon radius change, while in case B it was mostly influenced by the cardiac one. Furthermore, during total assistance, a blood stagnation occurred in the ascending aorta; in the case of partial assistance, the flow was orderly when the IABP was on and was chaotic when the balloon was off. Moreover, the mean arterial pressure (MAP) was higher in case B. The wall shear stress was worse in ascending aorta in case A. Partial support is hemodynamically advisable.
Khan, Habib; Uzzaman, Mohsin; Benedetto, Umberto; Butt, Salman; Raja, Shahzad G
2017-11-01
Coronary artery bypass grafting (CABG) is being increasingly offered to octogenarians. Both on- and off-pump CABG are reported as effective surgical revascularization strategies for octogenarians by single institution studies. However, the issue of superiority of one strategy over the other for octogenarians remains unresolved due to limited sample size of these studies. A meta-analysis of studies comparing outcomes of on- and off-pump CABG in octogenarians was undertaken to address the issue. A literature search was conducted from 1966 through September 2016 using MEDLINE, EMBASE, Scopus and Web of Science to identify relevant articles. Primary outcomes of interest included in-hospital mortality and stroke. Secondary outcomes of interest were atrial fibrillation, acute renal failure, reoperation for bleeding, deep sternal wound infection, myocardial infarction, intensive therapy unit (ITU) stay and hospital stay. The random effects model was used to calculate the outcomes of both binary and continuous data to control any heterogeneity between the studies. Heterogeneity amongst the trials was determined by means of the Cochran Q value and quantified using the I 2 inconsistency test. All p-values were 2-sided and a 5% level was considered significant. Sixteen retrospective studies (18,685 on-pump patients and 8938 off-pump patients) were included in the systematic review. In-hospital mortality (pooled OR = 0.64, 95% CI = 0.44 to 0.93; p = 0.02), stroke rate (pooled OR = 0.61, 95% CI = 0.48 to 0.76; p < 0.001) and length of hospital stay (pooled WMD = +0.29, 95% CI = +0.02 to +0.56; p = 0.04) were significantly lower in the off-pump patients. Atrial fibrillation (p = 0.36), acute renal failure (p = 0.47), reoperation for bleeding (p = 0.99), deep sternal wound infection (p = 0.59), myocardial infarction (p = 0.93), and length of ITU stay (p = 0.27) were comparable. Off-pump compared to on-pump CABG offers surgical myocardial revascularization to octogenarians with lower in-hospital mortality, stroke rate and length of hospital stay with similar incidence of other adverse outcomes. Preferentially offering off-pump CABG to octogenarians could translate into reduced economic burden on the healthcare providers. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Mannacio, Vito Antonio; Di Tommaso, Luigi; Antignan, Anita; De Amicis, Vincenzo; Vosa, Carlo
2012-12-01
To determine the individual variability in the response to aspirin and/or clopidogrel and its impact on graft patency after off-pump coronary artery bypass grafting. A single-centre prospective randomised controlled study designed according to the Consolidated Standards of Reporting Trials statement. Randomisation was obtained by a computer-generated algorithm. University medical school in Italy. 300 patients who underwent off-pump coronary artery bypass grafting were randomised to receive aspirin (n=150) or aspirin plus clopidogrel (n=150). Aspirin 100 mg or aspirin 100 mg plus clopidogrel 75 mg daily was initiated when postoperative chest tube drainage was ≤ 50 ml/h for 2 h and patients were followed up for 12 months. Qualitative and quantitative assessment of platelet function, angiographic evaluation of coronary revascularisation by 64-slice CT and clinical outcome. In the aspirin group, 49 patients (32.6%) were aspirin resistant and, in the aspirin-clopidogrel group, 19 patients (12.6%) were aspirin and clopidogrel resistant. The platelet response to aspirin was similar in all aspirin responders despite the study arm (Aspirin Reaction Units 313.2 ± 44.8 vs 323.6 ± 53.6; p=0.07). The platelet response to clopidogrel was enhanced by aspirin in patients responsive to both aspirin and clopidogrel (synergistic effect) compared with responders to clopidogrel only (P2Y12 Reaction Units 139.9 ± 15.5 vs 179.4 ± 18.5; p<0.001). Combined therapy was associated with a reduced vein graft occlusion rate (7.4% vs 13.1%; p=0.04). Antiplatelet resistance was a predictor of graft occlusion (RR 3.6, 95% CI 2.5 to 6.9; p<0.001). Synergistic aspirin and clopidogrel activity was a strong predictor of vein graft patency (RR 5.1, 95% CI 1.4 to 16.3; p<0.01). Combined clopidogrel and aspirin overcome single drug resistances, are safe for bleeding and improve venous graft patency.
Privratsky, Jamie R; Diaz, Sebastian; Nicoara, Alina; Daneshmand, Mani A
2018-05-01
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is an increasingly utilized life-saving measure. However, left-ventricular distention from inadequate left-ventricular off-loading can lead to unwanted pulmonary and cardiac complications. We are writing to indicate our agreement with a recent article by Brechot et al. published in the June 2017 issue where the authors demonstrated that intra-aortic balloon pump provides mechanical support to off-load the left ventricle during VA-ECMO, which prevents pulmonary edema.
[Systemic coronary surgery in the beating heart. Experience in 250 cases].
Cartier, R; Bouchard, D; Martineau, R; Couturier, A
1999-01-01
To report our recent experience with off-pump coronary artery revascularization in multi-vessel disease. Between October 1996 and August 1998, 250 off-pump (OP) procedures were completed at the Montreal Heart Institute, representing more than 90% of all procedures done during the same time frame (97% for 1998). These patients have been compared to 1870 patients operated upon under cardiopulmonary bypass during the years 1995-1996 (CPB). Mean age, sexe distribution, and preoperative risk factors were comparable for both groups. On average 2.89 +/- 0.8 and 2.84 +/- 0.6 grafts/patient were completed in OP and CPB groups respectively. A majority (70%) of patients had either a triple or quadruple bypass. Coronary anastomoses were achieved with myocardial mechanical stabilization and heart "verticalization". Ischemic time was shorter in the OP group (29.8 +/- 0.9 vs 45 +/- 0.4 min, p < 0.05). Similarly, need for transfusion was significantly less (OP: 34 vs CPB: 66%, p < 0.005). Use of postoperative intra-aortic counterpulsation as well as the raise of CK-MB were lesser in the OP group. Operative mortality (OP: 1.6%, vs CPB: 2%, p = ns) and perioperative myocardial infarction rate (OP: 3.6% vs CPB: 4.2) were comparable for both groups. Off-pump complete coronary artery revascularization is an acceptable alternative to conventional surgery in a majority of patients with good results given progressive experience, rigorous technique, and adequate coronary artery stabilization.
Off-pump coronary artery bypass grafting. The 1st Medical Faculty of Charles University study.
Semrád, M; Bodlák, P; Stríteský, M; Kristof, J; Lindner, J; Urban, T; Vondrácek, V; Vanĕk, I
2002-01-01
To explore the surgical technique, anaesthesiological management, immediate and mid-term results, graft patency and effectiveness of less invasive coronary artery bypass grafting through a median sternotomy. From January 1998 through December 1999, 144 patients had coronary artery bypass grafting (CABG) without cardiopulmonary bypass (CPB) done by one surgeon through a median sternotomy. The cohort of 107 men and 37 women averaged 60.8 years, mean ejection fraction (EF) was 51.8%. An average of 2.7 (range 1 to 5) grafts/patients was achieved. Results are compared with a CPB subgroup of patients operated on through a median sternotomy in the same time (N = 234). In a random subgroup of 100 patients (50 per group) an angiographic control of graft patency was done. A non-CPB group showed less postoperative acute myocardial infarction (0.7% vs. 3.8%, p < 0.05) and atrial fibrillation (14.6% vs. 26%, p < 0.05), lower incidence of renal (2.8% vs. 5.1%, p < 0.05) and respiratory complications (2.0% vs. 3.8%, NS). We observed lower operative mortality (0.7% vs. 3.4%, p < 0.05), as well as the occurrence of low cardiac output syndrome (0.7% vs. 5.6%, p < 0.05) in the off-pump group. The follow-up is 36 +/- 12 months and the number of patients with recurrent angina, late AMI and late death is acceptable. We did not find an inordinate number of vein grafts occlusions (0.7% vs. 1.8%, NS) and stenoses (6.6% vs. 6.7%, NS) at anastomotic sites. None of the arterial grafts in both groups were occluded. There was little known about the efficacy of the less invasive coronary artery bypass grafting at the beginning of our study. Starting with pioneering the operative technique, we have discovered and proposed three types of a heart verticalization and a reusable stabilizing device. We detected lower incidence of postoperative complications and decreased operative mortality in a non-CPB group. Angiographic assessment displayed an excellent run-off in both groups of patients. Off-pump coronary bypass grafting is associated with sufficient short-term graft patency and mid-term clinical outcomes.
Tamura, Atsushi; Imamaki, Mizuho; Shimura, Hitoshi; Niitsuma, Yuriko; Miyazaki, Masaru
2011-01-01
The aim of this study was to quantify the amount of brain damage suffered by patients who underwent off-pump coronary artery bypass grafting (OPCAB) in which S-100β protein and neuron-specific enolase were used. Thirty-four patients undergoing scheduled OPCAB were enrolled in the study. The patients were divided into two groups according to the results of their magnetic resonance angiography (MRA) and cervical ultrasonography: 13 patients had cervical or intracranial arterial stenosis (Group A), and 21 patients did not (Group B). Blood samples were collected from the arterial catheters immediately before surgery, upon arrival to the intensive care unit, and 6 and 24 hours after surgery. In blood samples collected from patients upon arrival to the intensive care unit, the maximum concentration of serum s-100β protein in Group A was significantly higher than that of Group B (p = 0.029). Though patients in Group A tended to have higher maximum neuron-specific enolase (NSE) concentrations, there were no significant differences in NSE concentrations at any point between the two groups. Our findings show a correlation between the stenosis detected by MRA or cervical ultrasonography and brain damage after OPCAB.
Winkler, Bernhard; Heinisch, Paul P; Gahl, Brigitta; Aghlmandi, Soheila; Jenni, Hans Jörg; Carrel, Thierry P
2017-01-01
The pathophysiologic side effects of cardiopulmonary bypass have already been identified. Minimally invasive extracorporeal circulation technologies (MiECT) and off-pump coronary artery bypass graft surgery (OPCABG) aim to reduce these problems. This meta-analysis provides a comparison of MiECT and OPCABG in randomized and observational studies. A fully probabilistic, Bayesian approach of primary and secondary endpoints was conducted. MiECT does not give inferior results when compared with OPCABG. However, there is a trend to borderline significantly higher blood loss in this group in randomized controlled trials. The question whether MiECT is equivalent to OPCABG can be answered with the affirmative, but long-term follow-up data are needed to detect any advantage over time. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Al Tmimi, Layth; Devroe, Sarah; Dewinter, Geertrui; Van de Velde, Marc; Poortmans, Gert; Meyns, Bart; Meuris, Bart; Coburn, Mark; Rex, Steffen
2017-10-01
Xenon was shown to cause less hemodynamic instability and reduce vasopressor needs during off-pump coronary artery bypass (OPCAB) surgery when compared with conventionally used anesthetics. As xenon exerts its organ protective properties even in subanesthetic concentrations, we hypothesized that in patients undergoing OPCAB surgery, 30% xenon added to general anesthesia with propofol results in superior hemodynamic stability when compared to anesthesia with propofol alone. Fifty patients undergoing elective OPCAB surgery were randomized to receive general anesthesia with 30% xenon adjuvant to a target-controlled infusion of propofol or with propofol alone. The primary end point was the total intraoperative dose of norepinephrine required to maintain an intraoperative mean arterial pressure >70 mm Hg. Secondary outcomes included the perioperative cardiorespiratory profile and the incidence of adverse and serious adverse events. Adding xenon to propofol anesthesia resulted in a significant reduction of norepinephrine required to attain the predefined hemodynamic goals (cumulative intraoperative dose: median [interquartile range]: 370 [116-570] vs 840 [335-1710] µg, P = .001). In the xenon-propofol group, significantly less propofol was required to obtain a similar depth of anesthesia as judged by clinical signs and the bispectral index (propofol effect site concentration [mean ± SD]: 1.8 ± 0.5 vs 2.8 ± 0.3 mg, P≤ .0001). Moreover, the xenon-propofol group required significantly less norepinephrine during the first 24 hours on the intensive care unit (median [interquartile range]: 1.5 [0.1-7] vs 5 [2-8] mg, P = .048). Other outcomes and safety parameters were similar in both groups. Thirty percent xenon added to propofol anesthesia improves hemodynamic stability by decreasing norepinephrine requirements in patients undergoing OPCAB surgery.
Endo, Daisuke; Kato, Tomoko S; Iwamura, Tai; Oishi, Atsumi; Yokoyama, Yasutaka; Kuwaki, Kenji; Inaba, Hirotaka; Amano, Atsushi
2017-06-01
Stroke is a major adverse event in patients developing atrial fibrillation (AF) after cardiac surgery. Surgical left atrial appendage amputation/ligation (LAA-A/L) during off-pump coronary artery bypass grafting (OPCAB) is routinely performed in our institution. We analyzed 578 consecutive patients (mean age 69 years, male 82%) undergoing OPCAB with or without concomitant LAA-A/L from 2011 to 2014 at our institution in a prospective observational manner. The safety and efficacy of the concomitant LAA-A/L on preventing early (<30 days) and overall postoperative stroke were examined. A total of 193 patients (33.4%) underwent LAA-A/L, consisting of amputation in 154 and ligation in 39 patients (80 and 20% of the cases, respectively). Preoperative characteristics, operative time, requirement of blood transfusion, and 30-day mortality were not significantly different between those with and without LAA-A/L. The incidences of postoperative AF and early and overall stroke were not significantly different between the groups in the analysis based on a total cohort. In a subanalysis of patients without LAA-A/L, early and overall stroke occurred more frequently in those developing postoperative AF than those without AF (2.8 vs. 0%; p = 0.005, 6.2 vs. 1.5%; p = 0.017, respectively), while in patients receiving LAA-A/L, stroke incidences did not differ between those with and without AF. Multivariate logistic regression showed postoperative AF without LAA-A/L as the only independent positive predictor of overall stroke (OR 3.69, p = 0.03). Concomitant LAA-A/L with OPCAB can safely prevent postoperative stroke occurrence in case patients develop AF, the most common arrhythmia associated with stroke.
Ohira, Suguru; Doi, Kiyoshi; Numata, Satoshi; Yamazaki, Sachiko; Itatani, Keiichi; Kawajiri, Hidetake; Morimoto, Kazuki; Yaku, Hitoshi
2017-10-01
To investigate the results of off-pump coronary artery grafting (OPCAB) with the proximal suture device (PSD) regarding postoperative stroke and graft patency. The PSD was used in 376 patients (32.0%), aorta-no-touch OPCAB was performed in 523 patients (45.2%), on-pump beating coronary artery bypass surgery (CABG) (on-beat group) in 125 patients (10.6%) including 51 conversions (conversion rate: 5.4%), and CABG with aortic clamp use (clamp group) in 152 patients. In the PSD group, Enclose II was used in 267 patients (71.0%). The hospital mortality rate was 1.95%. There was no early stroke in the OPCAB group, whereas the early-stroke rate was 0.8% in the on-beat group and 2.6% in the clamp group. The incidences of stroke at one month were: PSD group, 1.6%; no-touch group, 1.1%; on-beat group, 1.6%; and clamp group, 4.6% (p=0.014). The rates of complete revascularisation were higher in the PSD and clamp groups (94.7 and 94.0%, respectively) compared with the no-touch and on-beat groups (81.5 and 84.9%, respectively; p<0.001). The vein graft patency rates were comparable between the PSD and clamp groups. In multiple logistic regression analysis, OPCAB using the PSD did not increase the risk of stroke compared with the no-touch group (adjusted odds ratio [AOR]: 1.40; p=0.594) or on-beat group (AOR: 0.99; p=0.206), but reduced the risk of stroke compared with the clamp group (AOR: 0.19; p=0.005). Off-pump coronary artery grafting using the PSD was a safe and effective procedure. It led to lower incidences of postoperative stroke and excellent rates of graft patency and complete revascularisation compared with conventional CABG. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Off-pump coronary bypass surgery adversely affects alveolar gas exchange.
Gasparović, Hrvoje; Unić, Daniel; Sutlić, Zeljko; Husedzinović, Ino; Biocina, Bojan; Rudez, Igor; Nikić, Nada; Jelić, Ivan
2008-03-01
While the introduction of off-pump myocardial revascularization (OPCAB) has initially shown promise in reducing respiratory complications inherent to conventional coronary surgery, it has failed to eradicate them. Our study focused on quantifying the lactate release from the lungs and the dysfunction at the level of the alveolar-capillary membrane precipitated by OPCAB at different time points after the insult. Furthermore, we aimed to determine the impact of pulmonary lactate production on systemic lactic acid concentrations. The study was conducted in a prospective observational fashion. Forty consecutive patients undergoing OPCAB were analyzed. The mean patient age was 60 +/- 10 years. The mean EUROScore was 3.8 +/- 2.9. The alveolar-arterial O2 gradient increased from 19 [range 9 to 30] to 26 [range 20 to 34] kPa (P < 0.001) and remained elevated up to 6 hours after surgery. It rapidly declined again by 18 hours postoperatively. The observed increase in the pulmonary lactate release (PLR) from a baseline value of 0.022 [range -0.074 to 0.066] to 0.089 [range 0.016 to 0.209] mmol/min/m2 at six hours postoperatively did not reach statistical significance (P = 0.105). The systemic arterial lactate (Ls) concentration increased from 0.94 [range 0.78 to 1.06] to 1.39 [range 0.97 to 2.81] mmol/L (P < 0.001). The venoarterial pCO2 difference showed no significant change in comparison to baseline values. The mortality in the studied group was 2.5% (1/40). The pulmonary lactate production showed a statistically significant correlation with the systemic lactate concentration (R = 0.46; P = 0.003). Pulmonary injury following off pump myocardial revascularization was evidenced by a prompt increase in the alveolar-arterial oxygen gradient. The alveolar-arterial O2 gradient correlated with the duration of mechanical ventilation.
Mayr, Benedikt; Firschke, Christian; Erlebach, Magdalena; Bleiziffer, Sabine; Krane, Markus; Joner, Michael; Herold, Ulf; Nöbauer, Christian; Lange, Rüdiger; Deutsch, Marcus-André
2018-02-26
Simultaneous surgical off-pump coronary revascularization and transcatheter aortic valve implantation (TAVI) as a hybrid procedure may be a therapeutic option for patients with a TAVI indication who are not suitable for percutaneous coronary intervention and for patients who have an indication for combined surgical aortic valve implantation and coronary artery bypass grafting but present with a porcelain aorta. Early outcomes of these patients are analysed in this study. From February 2011 to April 2017, hybrid TAVI/off-pump coronary artery bypass (OPCAB) was performed in 12 (60%) patients, hybrid TAVI/minimally invasive direct coronary artery bypass in 6 (30%) patients and staged TAVI/OPCAB in 2 (10%) patients. Endpoints of this study were 30-day mortality, device success and postoperative adverse events as defined by the updated Valve Academic Research Consortium (VARC-2). The median age at the time of surgery was 77 years [interquartile range (IQR), 70-81] with a median logistic EuroSCORE and Society of Thoracic Surgeons' Predicted Risk score of 16.1% (IQR, 9.3-28.1) and 3.9% (IQR, 2.2-5.6), respectively. The median Synergy between PCI with Taxus and Cardiac Surgery score was 16.5 (IQR, 9.8-22.8). TAVI implantation routes were transaortic in 9 (45%) patients, transapical and transfemoral in 5 (25%) patients each and transsubclavian in 1 (5%) patient. Complete myocardial revascularization was achieved in 75% of patients. Device success rate was 100%. Paravalvular aortic regurgitation did not exceed mild in any patient. Stroke/transient ischaemic attack, vascular complications and myocardial infarction were not observed. Re-exploration for bleeding was required in 1 (5%) patient. Thirty-day mortality was 0%. Hybrid OPCAB/MIDCAB and TAVI prove to be a safe and effective alternative treatment option in selected higher risk patients.
Lee, Eun-Ho; Kim, Wook-Jong; Kim, Ji-Yeon; Chin, Ji-Hyun; Choi, Dae-Kee; Sim, Ji-Yeon; Choo, Suk-Jung; Chung, Cheol-Hyun; Lee, Jae-Won; Choi, In-Cheol
2016-05-01
Hypoalbuminemia may increase the risk of acute kidney injury (AKI). The authors investigated whether the immediate preoperative administration of 20% albumin solution affects the incidence of AKI after off-pump coronary artery bypass surgery. In this prospective, single-center, randomized, parallel-arm double-blind trial, 220 patients with preoperative serum albumin levels less than 4.0 g/dl were administered 100, 200, or 300 ml of 20% human albumin according to the preoperative serum albumin level (3.5 to 3.9, 3.0 to 3.4, or less than 3.0 g/dl, respectively) or with an equal volume of saline before surgery. The primary outcome measure was AKI incidence after surgery. Postoperative AKI was defined by maximal AKI Network criteria based on creatinine changes. Patient characteristics and perioperative data except urine output during surgery were similar between the two groups studied, the albumin group and the control group. Urine output (median [interquartile range]) during surgery was higher in the albumin group (550 ml [315 to 980]) than in the control group (370 ml [230 to 670]; P = 0.006). The incidence of postoperative AKI in the albumin group was lower than that in the control group (14 [13.7%] vs. 26 [25.7%]; P = 0.048). There were no significant between-group differences in severe AKI, including renal replacement therapy, 30-day mortality, and other clinical outcomes. There were no significant adverse events. Administration of 20% exogenous albumin immediately before surgery increases urine output during surgery and reduces the risk of AKI after off-pump coronary artery bypass surgery in patients with a preoperative serum albumin level of less than 4.0 g/dl.
Influence of body size on outcomes of off-pump coronary artery bypass surgery.
Yap, Alexander; Baladi, Naoum; Zapolanski, Alex; Pliam, Michael B; Shaw, Richard E
2005-01-01
Patients of small physical stature may be more likely selected for an on-pump coronary artery surgery (ONCAB) rather than an off-pump procedure (OPCAB). Small patients who do have OPCAB may do poorly. Our hospital demographics afford a unique opportunity to examine a group of small patients. Information was available over the past 4 years on 1015 patients who had isolated CABG and a calculable body surface area. Sixty-one patients had a body surface area of less than 1.5 m2 (SMALL). The 954 remaining patients were classed as larger (LARGER). Patients were compared with respect to preoperative risk factors, operative procedures, and postoperative results. Among SMALL patients, 59% were Asian, 89% female, averaged slightly older, had higher STS risk scores, lower hematocrits, more severe NYHA class ratings, and less elective surgical status (P < .05) than LARGER patients. Fifty-one percent of SMALL patients had OPCAB, 44.3% received blood, 90% had an event-free course, and 4.9% died postop (versus 1.2%, P < .05). OPCAB mortality was lower than ONCAB for both SMALL and nonsmall (P < .05). Blood use was greater for SMALL than for LARGER (44% versus 20%, P < .05) but less for SMALL OPCAB than SMALL ONCAB (27% versus 62%, P < .05). No differences were noted in postop MI, CVA, or length of stay, but 30-day readmission was lower for SMALL patients (5.0% versus 7.4%). Patients with small physical stature can be safely operated upon using off-pump techniques with good revascularization and postop results, despite apparently higher preop STS risk scores.
Dohi, Masahiro; Miyata, Hiroaki; Doi, Kiyoshi; Okawa, Kazunari; Motomura, Noboru; Takamoto, Shinichi; Yaku, Hitoshi
2015-02-01
The benefits of off-pump coronary artery grafting (OPCAB) have been demonstrated. Especially in patients with a high number of comorbidities, redo coronary artery bypass grafting (CABG) remains a difficult entity of CABG, because patients are likely to have multiple risk factors and often have diseased patent grafts with adhesions. The aim of the present study was to evaluate the effects of the OPCAB technique in redo CABG on mortality and morbidity using data from the Japan Cardiovascular Surgery Database (JCVSD). We analysed 34 980 patients who underwent isolated CABG between 2008 and 2011, as reported in the JCVSD. Of these, 1.8% of patients (n = 617/34980) had undergone redo CABG, including those who underwent OPCAB (n = 364; 69%) and on-pump CABG (n = 253; 41%). We used propensity score (PS) matching with 13 preoperative risk factors to adjust for differences in baseline characteristics between the redo OPCAB and on-pump redo CABG groups. By one-to-one PS matching, we selected 200 pairs from each group. There were no significant differences in patient background between the redo OPCAB and on-pump redo CABG groups after PS matching. There was no significant difference in the mean number of distal anastomoses after matching (2.41 ± 1.00 vs 2.21 ± 1.04, P = 0.074); nevertheless, the mean operation time was significantly shorter in the redo OPCAB than the on-pump redo CABG group (353.7 vs 441.3 min, P < 0.00010). Patients in the redo OPCAB group had a lower 30-day mortality rate (3.5 vs 7.0%, P = 0.18), a significantly lower rate of composite mortality or major morbidities (11.0 vs 21.5%, P = 0.0060), a significantly lower rate of prolonged ventilation (>24 h) (7.0 vs 15.0%, P = 0.016), a significantly shorter duration of intensive care unit (ICU) stay (ICU stay ≥ 8 days) (7.0 vs 14.5%, P = 0.023) and a significantly decreased need for blood transfusions (71.5 vs 94.0%, P < 0.00010) than patients in the on-pump redo CABG group. The off-pump technique reduced early operative mortality and the incidences of major complications in redo CABG. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Igarashi, Takashi; Iwai-Takano, Masumi; Wakamatsu, Hiroki; Haruta, Mineyuki; Omata, Sadao; Yokoyama, Hitoshi
2018-01-01
This study aimed to assess the deformation of the mitral valve complex during the displacement of the beating heart by using three-dimensional echocardiography in a porcine off-pump coronary artery bypass grafting (OPCAB) model. In nine healthy swine, we positioned the beating heart as an OPCAB model, i.e. control, left anterior descending artery (LAD), right coronary artery (RCA), and left circumflex artery (LCX) positions. In each position, three-dimensional echocardiography was performed to assess the mitral valve complex with hemodynamic parameters. We analyzed the deformation of the mitral valve and the three-dimensional coordinates of the papillary muscles. There was a significant increase in maximum tenting length and tenting volume (control 0.70±0.30, LAD 0.65±0.27, RCA 0.79±0.23, LCX 0.95±0.34cm 3 , p<0.05) in the LCX position compared with the other positions. The posterior papillary muscle (PPM) angle had a significant relationship with the tenting volume (r=-0.643, p<0.001). The PPM was displaced to the medial side in the LAD and LCX positions (p<0.01). The prime cause of the deformation of the mitral leaflets is suggested to be the displacement of the PPM associated with the change in geometry of the left ventricle in a porcine model. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Elementary theory of synchronous arterio-arterial blood pumps
NASA Technical Reports Server (NTRS)
Jones, R. T.; Petscheck, H. E.; Kantrowitz, A. R.
1976-01-01
In the technique of arterio-arterial pumping, a volume of fluid is withdrawn from the aorta during systole and reinjected during diastole, thereby reducing the systolic pressure of the heart and adding energy to the systemic circulation. It is found that an upper bound for the effectiveness of such devices is given by a formula that considers stroke output of the unaided heart and the increment caused by the pump with a stroke. The division of effort of the pump between the reduction of pressure and the increase of flow depends on the physiological mechanical impedance of the heart. The total effect is, however, independent of the impedance.
Kobayashi, S; Owada, N; Yambe, T; Nitta, S; Fukuju, T; Hongoh, T; Hashimoto, H
1999-08-01
A vibrating flow pump (VFP) can generate high frequency oscillated blood flow within 10-30 Hz by the oscillation of its central tube. A totally implantable artificial heart using a VFP is being developed as a unique type of blood pump. In this study, left ventricular (LV) assist circulation was performed using a VFP. The total vascular resistance and driving frequency of the VFP were estimated from their relationship. The effect of oscillation on the vascular system was studied by the frequency analysis method and vascular impedance. Adult goats were anesthetized by halothane using an inhaler and a left fourth thoracotomy was performed. The inflow cannula was inserted into the left ventricle, and the outflow cannula was sutured to the descending aorta. The VFP and a centrifugal pump were set in parallel for alternation and comparison. The driving frequency of the VFP was changed and included 15, 20, 25, and 30 Hz. The hemodynamic parameters were continuously recorded during experiments by a digital audio tape (DAT) data recorder. The internal pressure of the left ventricular cavity and aortic pressure were monitored by the pressure manometers continuously. One hundred percent LV assistance was judged by the separation of LV and aortic pressure. The total vascular resistance was decreased by the start of operation of each pump. The decrease during flow using the VFP was not as large as that using a centrifugal pump (CP). The arterial input impedance during oscillated blood flow by the VFP showed a slow curve appearance. It was similar to the frequency characteristics curve of natural heart beats within the lower frequencies. The study of arterial impedance may be important for the estimation of the reflection of the pulsatile wave from the arterial branch, among other things.
Tashiro, Naonori; Takahashi, Shinya; Takasaki, Taiichi; Katayama, Keijiro; Taguchi, Takahiro; Watanabe, Masazumi; Kurosaki, Tatsuya; Imai, Katsuhiko; Kimura, Hiroaki; Sueda, Taijiro
2015-01-01
Postoperative complications after cardiac surgery increase mortality. This study aimed to evaluate the efficacy of cardiopulmonary rehabilitation with adaptive servo-ventilation (ASV) in patients undergoing off-pump coronary artery bypass grafting (OPCAB). A total of 66 patients undergoing OPCAB were enrolled and divided into 2 groups according to the use of ASV (ASV group, 30 patients; non-ASV group, 36 patients). During the perioperative period, all patients undertook cardiopulmonary rehabilitation. ASV was used from postoperative day (POD) 1 to POD5. Hemodynamics showed a different pattern in the 2 groups. Blood pressure (BP) on POD6 in the ASV group was significantly lower than that in the non-ASV group (systolic BP, 112.9±12.6 vs. 126.2±15.8 mmHg, P=0.0006; diastolic BP, 62.3±9.1 vs. 67.6±9.3 mmHg, P=0.0277). The incidence of postoperative atrial fibrillation (POAF) was lower in the ASV group than in the non-ASV group (10% vs. 33%, P=0.0377). The duration of oxygen inhalation in the ASV group was significantly shorter than that in the non-ASV group (5.1±2.2 vs. 7.6±6.0 days, P=0.0238). The duration of postoperative hospitalization was significantly shorter in the ASV group than in the non-ASV group (23.5±6.6 vs. 29.0±13.1 days, P=0.0392). Cardiopulmonary rehabilitation with ASV after OPCAB reduces both POAF occurrence and the duration of hospitalization.
Mejía, Omar Asdrúbal Vilca; Sá, Michel Pompeu Barros Oliveira; Deininger, Maurilio Onofre; Dallan, Luís Roberto Palma; Segalote, Rodrigo Coelho; Oliveira, Marco Antonio Praça de; Atik, Fernando Antibas; Santos, Magaly Arrais Dos; Silva, Pedro Gabriel Melo de Barros E; Milani, Rodrigo Mussi; Hueb, Alexandre Ciappina; Monteiro, Rosangela; Lima, Ricardo Carvalho; Lisboa, Luiz Augusto Ferreira; Dallan, Luís Alberto Oliveira; Puskas, John; Jatene, Fabio Biscegli
2017-01-01
Advances in modern medicine have led to people living longer and healthier lives. Frailty is an emerging concept in medicine yet to be explored as a risk factor in cardiac surgery. When it comes to CABG surgery, randomized controlled clinical trials have primarily focused on low-risk (ROOBY, CORONARY), elevated-risk (GOPCABE) or high-risk patients (BBS), but not on frail patients. Therefore, we believe that off-pump CABG could be an important technique in patients with limited functional capacity to respond to surgical stress. In this study, the authors introduce the new national, multicenter, randomized, controlled trial "FRAGILE", to be developed in the main cardiac surgery centers of Brazil, to clarify the potential benefit of off-pump CABG in frail patients. FRAGILE is a two-arm, parallel-group, multicentre, individually randomized (1:1) controlled trial which will enroll 630 patients with blinded outcome assessment (at 30 days, 6 months, 1 year, 2 years and 3 years), which aims to compare adverse cardiac and cerebrovascular events after off-pump versus on-pump CABG in pre-frail and frail patients. Primary outcomes will be all-cause mortality, acute myocardial infarction, cardiac arrest with successful resuscitation, low cardiac output syndrome/cardiogenic shock, stroke, and coronary reintervention. Secondary outcomes will be major adverse cardiac and cerebrovascular events, operative time, mechanical ventilation time, hyperdynamic shock, new onset of atrial fibrillation, renal replacement therapy, reoperation for bleeding, pneumonia, length of stay in intensive care unit, length of stay in hospital, number of units of blood transfused, graft patency, rate of complete revascularization, neurobehavioral outcomes after cardiac surgery, quality of life after cardiac surgery and costs. FRAGILE trial will determine whether off-pump CABG is superior to conventional on-pump CABG in the surgical treatment of pre-frail and frail patients. ClinicalTrials.gov, ID: NCT02338947. Registered on August 29th 2014; last updated on March 21st 2016.
Suwalski, Grzegorz; Emery, Robert; Mróz, Jakub; Kaczejko, Kamil; Gryszko, Leszek; Cwetsch, Andrzej; Skrobowski, Andrzej
2017-06-01
Concomitant surgical ablation of atrial fibrillation (AF) is recommended for patients undergoing off-pump coronary revascularization in the presence of this arrhythmia. Achievement of optimal visualization of pulmonary veins while maintaining stable haemodynamic conditions is crucial for proper completion of the ablation procedure. This study evaluates the safety and feasibility of right atrial positioning using a suction-based cardiac positioner as opposed to compressive manoeuvres for exposure during off-pump surgical ablation for AF. Thirty-four consecutive patients underwent pulmonary vein isolation, ganglionated plexi ablation and left atrial appendage occlusion during off-pump coronary artery bypass grafting. Right atrial suction positioning was used to visualize right pulmonary veins. Safety and feasibility end points were analysed intraoperatively and in the early postoperative course. In all patients, right atrial positioning created optimal conditions to complete transverse and oblique sinus blunt dissection, correct placement of a bipolar ablation probe, detection and ablation of ganglionated plexi and conduction block assessment. In all patients, this entire right-sided ablation procedure was completed with a single exposure manoeuvre. Feasibility end points were achieved in all study patients. This report documents the safety and feasibility of right atrial exposure using a suction-based cardiac positioner to complete ablation for AF concomitant with off-pump coronary revascularization. This technique may be widely adopted to create stable haemodynamic conditions and optimal visualization of the right pulmonary veins. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Lee, Jong Hwa; Oh, Young Jun; Shim, Yon Hee; Hong, Yong Woo; Yi, Gijong
2006-01-01
This investigation evaluated the effect of continuous milrinone infusion on right ventriclular (RV) function during off-pump coronary artery bypass graft (OPCAB) surgery in patients with reduced RV function. Fifty patients scheduled for OPCAB, with thermodilution RV ejection fraction (RVEF) <35% after anesthesia induction, were randomly allocated to either milrinone (0.5 µg/kg/min) or control (saline) group. Hemodynamic variables and RV volumetric data measured by thermodilution method were collected as follows: after anesthesia induction (T1); 10 min after heart displacement for obtuse marginal artery anastomosis (T2); after pericardial closure (T3). Cardiac index and heart rate increased and systemic vascular resistance significantly decreased in milrinone group at T2. Initially lower RVEF of milrinone group was eventually comparable to control group after milrinone infusion. RVEF did not significantly change at T2 and T3 in both groups. RV end-diastolic volume in milrinone group consistently decreased from the baseline at T2 and T3. Continuous infusion of milrinone without a bolus demonstrated potentially beneficial effect on cardiac output and RV afterload in patients with reduced RV function during OPCAB. However, aggressive augmentation of intravascular volume seems to be necessary to maximize the effect of the milrinone in these patients. PMID:17043419
Moscarelli, Marco; Harling, Leanne; Ashrafian, Hutan; Athanasiou, Thanos
2013-03-01
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether off-pump coronary artery bypass (OPCAB) grafting should be considered as an alternative to the conventional on-pump surgery (ONCAB) in patients presenting with acute coronary syndrome (ACS) requiring emergency revascularization. Eighty-two papers were identified by a systematic search, of which nine were judged to best answer the clinical question. Of these, one was a randomized controlled trial and the remaining eight were retrospective observational studies. The author, journal, date, patient group, country of publication, relevant outcomes, results and study weaknesses were tabulated. In total, these nine studies included 3001 patients (n = 817 OPCAB, 2184 ONCAB) undergoing emergency revascularization in the setting of ACS. The timing between the onset of ACS and operative intervention ranged from 6 to 72 h. All cases were categorized as urgent/emergent according to the National confidential enquiry into patient outcome and death classification of intervention. Six studies included patients with preoperative cardiogenic shock; however the majority of patients were haemodynamically stable at the time of surgery. Three out of nine studies showed an improvement in 30-day mortality with OPCAB although the remaining six reveal no significant mortality benefit. No difference in long-term mortality was observed between the two techniques. OPCAB was associated with significantly fewer grafts per patient (six studies) and less complete revascularization (two studies). We conclude that whilst OPCAB may have a beneficial effect on 30-day mortality in haemodynamically stable patients undergoing emergency revascularization, there is a lack of high-quality data with clearly defined patient demographics. Future studies must ensure adequate preoperative matching between OPCAB and ONCAB groups and clearly categorize haemodynamic status, disease pattern and time to surgery in order to determine the patients in whom OPCAB may confer the greatest benefit.
Results of completion arteriography after minimally invasive off-pump coronary artery bypass.
Hoff, Steven J; Ball, Stephen K; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Petracek, Michael R; Ahmad, Rashid; Greelish, James P; Walker, Kristie; Byrne, John G
2011-01-01
The benefits of a minimally invasive approach to off-pump coronary artery bypass remain controversial. The value of completion arteriography in validating this technique has not been investigated. From April 2007 to October 2009, fifty-six patients underwent isolated minimally invasive coronary artery bypass grafting through a left thoracotomy without cardiopulmonary bypass. Forty-three of these patients underwent completion arteriography. Sixty-five grafts were performed in these 56 patients, (average, 1.2 grafts per patient; range, 1 to 3). Forty-eight grafts were studied in the 43 patients undergoing completion arteriography. There were 4 findings on arteriogram leading to further immediate intervention (8.3%). These included 3 grafts with anastomotic stenoses or spasm requiring stent placement, and 1 patient who had limited dissection in the left internal mammary artery graft and underwent placement of an additional vein graft. These findings were independent of electrocardiographic changes or hemodynamic instability. The remainder of the studies showed no significant abnormalities. There were no deaths. One patient who did not have a completion arteriogram suffered a postoperative myocardial infarction requiring stent placement for anastomotic stenosis. Patients were discharged home an average of 6.8 days postoperatively. There were no instances of renal dysfunction postoperatively attributable to catheterization. Minimally invasive coronary artery bypass is safe and effective. Findings of completion arteriography occasionally reveal previously under-recognized findings that, if corrected in a timely fashion, could potentially impact graft patency and clinical outcomes. Our experience validates this minimally invasive technique. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Ramchandani, M; Bedeir, K
2011-01-01
The revival of off-pump cardiac surgery and the exploration of less invasive techniques for coronary artery bypass grafting, have lead to an increasing technical difficulty, as compared to conventional surgery using cardiopulmonary bypass. The moving target vessel in off-pump coronary artery bypass surgery, as well as the increasingly limited space in minimally invasive cardiac surgery were not convenient to many surgeons, a fact that lead many surgeons to deprive their patients the potential benefits of these techniques. Since the 1950's, surgeons have attempted to make the anastomotic procedure less cumbersome and less time consuming. Many creative ideas and devices were made, but for many different reasons, they eventually faded away. Since then, hand-sewn anastomoses have been the standard of care in coronary artery bypass grafting. Today, with the obvious need for a facilitated and fast coronary anastomosis, interest in these anastomotic devices has been re-awakened. The exact geometry, physiology and dynamics of the perfect anastomosis have thus been studied, in an attempt to provide an understanding of reasons behind anastomosis and graft failure after coronary artery bypass surgery, and eventually design the best performing device. These devices would allow for a faster, more accurate and a more reproducible coronary anastomosis using minimally invasive techniques. Also, due to a short learning curve, the standardization of percutaneous devices would allow much more surgeons to more widely adopt less invasive techniques. In summary, we see anastomotic devices as a solution to the technical challenges surgeons encounter with minimally invasive coronary artery bypass grafting.
Frazier, O H; Tuzun, Egemen; Cohn, William E; Conger, Jeffrey L; Kadipasaoglu, Kamuran A
2006-01-01
Continuous-flow pumps are small, simple, and respond physiologically to input variations, making them potentially ideal for total heart replacement. However, the physiological effects of complete pulseless flow during long-term circulatory support without a cardiac interface or with complete cardiac exclusion have not been well studied. We evaluated the feasibility of dual continuous-flow pumps as a total artificial heart (TAH) in a chronic bovine model. Both ventricles of a 6-month-old Corriente crossbred calf were excised and sewing rings attached to the reinforced atrioventricular junctions. The inlet portions of 2 Jarvik 2000 pumps were positioned through their respective sewing rings at the mid-atrial level and the pulseless atrial reservoir connected end-to-end to the pulmonary artery and aorta. Pulseless systemic and pulmonary circulations were thereby achieved. Volume status was controlled, and systemic and pulmonary resistance were managed pharmacologically to keep mean arterial pressures at 100+/-10 mmHg (systemic) and 20+/-5 mmHg (pulmonary) and both left and right atrial pressures at 15+/-5 mmHg. The left pump speed was maintained at 14,000 rpm and its output autoregulated in response to variations in right pump flow, systemic and pulmonary pressures, fluid status, and activity level. Hemodynamics, end-organ function, and neurohormonal status remained normal. These results suggest the feasibility of using dual continuous-flow pumps as a TAH.
Formica, Francesco; Mariani, Silvia; Broccolo, Francesco; Caruso, Rosa; Corti, Fabrizio; D'Alessandro, Stefano; Amigoni, Pietro; Sangalli, Fabio; Paolini, Giovanni
2013-01-01
Inflammatory response and hemodilution are the main drawbacks of extracorporeal circulation. We hypothesize that the use of miniaturized extracorporeal circulation (MECC) might lower the systemic and myocardial inflammatory patterns compared with a standard system (SECC) and off-pump coronary artery bypass grafting (OPCABG). Sixty-one patients undergoing isolated coronary artery bypass graft were prospectively randomized to MECC (n = 19), SECC (n = 20), or OPCABG (n = 22). Blood samples were collected from radial artery and coronary sinus to analyze blood lactate, hemodilution, and markers for inflammation and endothelial activation such as tumor necrosis factor (TNF)-α, interleukin-6, monocyte chemotactic protein-1, and E-selectin. No differences were observed in early clinical outcome. Interleukin -6 levels increased in every group during and after cardiac surgery, whereas TNF-α values grew in the SECC group (p = 0.05). E-selectin systemic values decreased during and after operation (p = 0.001) in every group. Monocyte chemotactic protein-1 systemic and cardiac levels raised only in SECC group (p = 0.014). In conclusion, MECC is comparable to SECC and OPCABG in the clinical outcome of low-risk patients, and it might be extensively used with no additional intraoperative risk. The analysis of the inflammatory patterns of endothelial activation shows MECC as effective as OPCABG, suggesting further studies to clarify MECC recommendation in high-risk patients.
Marui, Akira; Kimura, Takeshi; Tanaka, Shiro; Okabayashi, Hitoshi; Komiya, Tatsuhiko; Furukawa, Yutaka; Kita, Toru; Sakata, Ryuzo
2012-12-15
The stroke rate after coronary artery bypass grafting (CABG) compared to percutaneous coronary intervention (PCI) is generally considered high because cardiopulmonary bypass and aortic manipulations are often associated with cerebrovascular complications. However, an increasing number of CABGs performed without cardiopulmonary bypass (OPCAB) may improve those outcomes. Of 6,323 patients with multivessel and/or left main coronary artery disease, 3,877 patients underwent PCI, 1,381 conventional on-pump CABG, and 1,065 OPCAB. Median follow-up was 3.4 years. Stroke types were classified as early (onset of stroke within 24 hours after revascularization), delayed (within 30 days), and late (after 30 days). Propensity score analysis showed that the incidences of early, delayed, and late stroke did not differ between PCI and OPCAB (0.65, 95% confidence interval 0.08 to 5.45, p = 1.00; 0.36, 0.10 to 1.29, p = 0.23; 0.81, 0.52 to 1.27, p = 0.72, respectively). In contrast, incidence of early stroke after on-pump CABG was higher than after OPCAB (7.22, 1.67 to 31.3, p = 0.01), but incidences of delayed and late stroke were not different (1.66, 0.70 to 3.91, p = 0.50; 1.18, 0.83 to 1.69, p = 0.73). In conclusion, occurrence of stroke was not found to differ in patients after PCI versus OPCAB regardless of onset of stroke. Occurrence of early stroke after OPCAB was lower than that after on-pump CABG, yet occurrences of delayed and late strokes were similar for the 3 revascularization strategies. Copyright © 2012 Elsevier Inc. All rights reserved.
2013-01-01
Background Coronary-artery-bypass-grafting (CABG) with conventional extracorporeal circulation (CECC) is associated with adverse effects such as systemic inflammatory response leading to a decrease in systemic vascular resistance and hemodynamic instability. Modern "less invasive" procedures have been established recently which potentially avoid negative side effects of CECC. The aim of this study was to compare perioperative outcome following coronary revascularization using either a minimized extracorporeal circuit (Mini-HLM) or off-pump technique (OPCAB). Methods In this prospective ethics-approved trial, 120 patients referred for CABG were randomly assigned either to off-pump coronary artery bypass (OPCAB) or to a Mini-HLM procedure. Patient demographics, preoperative characteristics and extensive postoperative outcome were analyzed for both groups. Hemodynamic data were measured at seven time points perioperatively. Results Operation-time was longer in the Mini-HLM group (178,3 ± 32,9 min) compared to OPCAB (133,2 ± 32,7 min, p < 0,001) with higher graft numbers in Mini-HLM group (3,11 ± 0,7 vs. 1,78 ± 0,7, p < 0.001). There were no significant differences in perioperative hemodynamic criteria, catecholaminergic support, hospital (p = 0,534) and intensive care unit stay (p = 0,880), ventilation time (p = 0,113), blood loss (p = 0,570), transfusion requirements, postoperative atrial fibrillation rate (p = 0,706) and neurocognitive disturbance (p = 0,297). No deaths and no myocardial infarctions were observed. Conclusions Coronary revascularisation with Mini-HLM represents a suitable and "less invasive" procedure which achieves all benefits of OPCAB but may allow for less demanding revascularisation than OPCAB in special patients with complex coronary anatomy and can therefore be used both on a routine basis and in all "conversion" cases of OPCAB. PMID:23577663
Guizilini, Solange; Alves, Daniel F; Bolzan, Douglas W; Cancio, Andreia S A; Regenga, Marisa M; Moreira, Rita S L; Trimer, Renata; Gomes, Walter J
2014-09-01
The aim of this trial was to compare functional capacity, pulmonary shunt fraction and clinical outcomes between patients undergoing pleurotomy with a pleural drain inserted in the sub-xyphoid position and patients with a pleural drain placed in the intercostal position after off-pump coronary artery bypass surgery. Patients were randomized into two groups according to the pleural drain site: Group II (n = 33 intercostal pleural drain); and Group SI (n = 35 sub-xyphoid pleural drain). Functional capacity was assessed by the distance covered on the 6-min walking test performed preoperatively and on postoperative day (POD) 5; in addition, pulmonary function test was determined preoperatively and on POD 1 and 5. Pulmonary shunt fraction was evaluated preoperatively and on POD 1, and clinical outcomes were recorded throughout the study. Group SI had better preservation of lung volumes and capacities in POD compared with Group II (P <0.05). Pulmonary shunt fraction increased in both groups postoperatively; however, Group SI showed a smaller pulmonary shunt fraction (0.26 ± 0.04 vs 0.21 ± 0.04%; P = 0.0014). Functional capacity was significantly reduced in both groups on POD 5; however, Group SI showed better preservation of functional capacity (P = 0.0001). Group SI had better postoperative clinical results, with lower incidence of atelectasis and pleural effusion (P <0.05), lower pain scores (P <0.0001), and shorter orotracheal intubation and hospitalization lengths (P <0.001). Sub-xyphoid pleural drain determined better functional capacity and exercise tolerance with a smaller pulmonary shunt fraction and improved clinical outcomes compared with intercostal pleural drainage after off-pump coronary artery bypass surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Cost considerations in selecting coronary artery revascularization therapy in the elderly.
Maziarz, David M; Koutlas, Theodore C
2004-01-01
This article presents some of the cost factors involved in selecting coronary artery revascularization therapy in an elderly patient. With the percentage of gross national product allocated to healthcare continuing to rise in the US, resource allocation has become an issue. Percutaneous coronary intervention continues to be a viable option for many patients, with lower initial costs. However, long-term angina-free results often require further interventions or eventual surgery. Once coronary artery revascularization therapy is selected, it is worthwhile to evaluate the cost considerations inherent to various techniques. Off-pump coronary artery bypass graft surgery has seen a resurgence, with improved technology and lower hospital costs than on-pump bypass surgery. Numerous factors contributing to cost in coronary surgery have been studied and several are documented here, including the potential benefits of early extubation and the use of standardized optimal care pathways. A wide range of hospital-level cost variation has been noted, and standardization issues remain. With the advent of advanced computer-assisted robotic techniques, a push toward totally endoscopic bypass surgery has begun, with the eventual hope of reducing hospital stays to a minimum while maximizing outcomes, thus reducing intensive care unit and stepdown care times, which contribute a great deal toward overall cost. At the present time, these techniques add a significant premium to hospital charges, outweighing any potential length-of-stay benefits from a cost standpoint. As our elderly population continues to grow, use of healthcare resource dollars will continue to be heavily scrutinized. Although the clinical outcome remains the ultimate benchmark, cost containment and optimization of resources will take on a larger role in the future. Copyright 2004 Adis Data Information BV
First Report of 90-Day Support of Two Calves with a Continuous-Flow Total Artificial Heart
Karimov, Jamshid H.; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A.; Fukamachi, Kiyotaka
2015-01-01
Objective The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. Methods CFTAH pumps have been implanted in 17 calves total. Hemodynamics, pump performance, and device-related adverse events were evaluated during studies and at necropsy. Results In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure [LAP], 16 ± 3 mm Hg; right atrial pressure [RAP], 17 ± 3 mm Hg; RAP-LAP difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three recent animals with the CFTAH recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last two were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. Conclusions The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. PMID:26173607
De Lazzari, Claudio; Genuini, Igino; Quatember, Bernhard; Fedele, Francesco
2014-02-01
Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from -4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched "ON" and both when PUCA is switched "OFF". By switching "OFF" the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to hybrid TAL assistance). Results concerning PUCA and TAL interaction produced by simulations cannot be compared with "in vivo" results since they are not presented in literature. But results concerning the effects produced by LVAD and mechanical ventilation have a trend consistent with those presented in literature. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Hadadzadeh, Mehdi; Hosseini, Seyed Habib; Mostafavi Pour Manshadi, Seyed Mohammad Yousof; Naderi, Nafiseh; Emami Meybodi, Mahmood
2013-01-01
Myocardial dysfunction is a major complication in cardiac surgery that needs inotropic support. This study evaluates the effect of milrinone on patients with low ventricular ejection fraction undergoing off- pump coronary artery bypass graft (OPCAB). The present study is designed to evaluate the effect of milrinone on myocardial dysfunction. Eighty patients with low ventricular ejection fraction (<35%), candidate for elective OPCAB, were enrolled in this study. They were randomly assigned to two groups. One group received milrinone (50 μg/kg) intravenously and another group received a saline as placebo followed by 24 hours infusion of each agent (0.5 μg/kg/min). Short outcome of patients such as hemodynamic parameters and left ventricular ejection fraction were variables evaluated. Serum levels of creatine phosphokinase, the MB isoenzyme of creatine kinase, occurrence of arrhythmias and mean duration of mechanical ventilation were significantly lower in milrinone group (P<0.05). The mean post operative left ventricular ejection fraction was significantly higher in milrinone group (P=0.031). There were no statistical significant differences between the two groups in terms of intra-aortic balloon pump, inotropic support requirement, myocardial ischemia, myocardial infarction, duration of inotropic support, duration of intensive care unit stay, mortality and morbidity rate. Administration of milrinone in patients undergoing OPCAB with low ventricular ejection fraction is useful and effective.
Chiarenza, Federica; Tsoutsouras, Theodoros; Cassisi, Cesare; Santonocito, Cristina; Gerry, Stephen; Astuto, Marinella; George, Shane; Sanfilippo, Filippo
2017-01-01
Respiratory complications are common after cardiac surgery and the use of extracorporeal circulation is one of the main causes of lung injury. We hypothesized a better postoperative respiratory function in off-pump coronary artery bypass grafting (OPCABG) as compared with "on-pump coronary artery bypass grafting" (ONCABG). This is a retrospective, single-center study at a cardiothoracic intensive care unit (ICU) in a tertiary university hospital. Consecutive data on 339 patients undergoing elective CABG (n = 215 ONCABG, n = 124 OPCABG) were collected for 1 year from the ICU electronic medical records. We compared respiratory variables (Pao 2 , Pao 2 /Fio 2 ratio, Sao 2 , and Paco 2 ) at 7 predefined time points (ICU admission, postoperative hours 1, 3, 6, 12, 18, and 24). We also evaluated time to extubation, rates of reintubation, and use of noninvasive ventilation (NIV). We used mixed-effects linear regression models (with time as random effect for clustering of repeated measures) adjusted for a predetermined set of covariates. The values of Pao 2 and Pao 2 /Fio 2 were significantly higher in the OPCABG group only at ICU admission (mean differences: 9.7 mm Hg, 95% confidence interval [CI] 3.1-16.2; and 27, 95% CI 6.1-47.7, respectively). The OPCABG group showed higher Paco 2 , overall ( P = .02) and at ICU admission (mean difference 1.8 mm Hg, 95% CI: 0.6-3), although mean values were always within normal range in both groups. No differences were seen in Sao 2 values, time to extubation, rate of reintubation rate, and use of postoperative NIV. Extubation rate was higher in OPCABG only at postoperative hour 12 (92% vs ONCABG 82%, P = .02). The OPCABG showed only marginal improvements of unlikely clinical meaning in oxygenation as compared to ONCABG in elective low-risk patients.
Khani, Mohammad; Hosseintash, Mahsa; Foroughi, Mahnoosh; Naderian, Mohammadreza; Khaheshi, Isa
2016-04-01
Right ventricle function significantly decreases after coronary artery bypass surgery; as one of the likely causes, such a condition is attributed to the use of cardiopulmonary pump (CPB). Because nowadays there is a tendency toward increasing use of off-pump coronary artery bypass (OPCAB) surgery, this study was conducted to evaluate the right ventricle function after this type of surgery using strain and strain rate imaging (SRI) echocardiography. This study was conducted on 30 patients, candidate for elective OPCAB surgery, between 2011 and 2012. Standard echocardiography was performed before the surgery and the right ventricle function was examined using strain and SRI echocardiography. Then patient underwent surgery, 6 days and 3 months after surgery they underwent echocardiography again and the results obtained from the three stages were compared with each other. Participants included 30 patients (23 males and 7 females) with a mean age of 66±11 years. Compared to the prior of the surgery, 6 days and 3 months after the surgery there was a significant decrease in tricuspid annular plane systolic excursion (TAPSE), tissue Doppler imaging (TDI) at the lateral annulus of tricuspid valve, and strain and SRI of right ventricle. However, the values obtained 3 months after surgery were significantly higher than those obtained after 6 days. In other words, the right ventricle function 6 days after the surgery had dropped, however some of the values recovered 3 months after the surgery. The findings of this study are consistent with other studies in this field and showed that after coronary artery surgery a decline occurs in right ventricular function. However, more detailed quantitative strain and SRI parameters which were measured in our study showed that at the early days after the OPCAB surgery there is a decline in the right ventricle function which is relatively reversible at longer intervals (3 months after surgery).
A new beating-heart off-pump coronary artery bypass grafting training model.
Bouma, Wobbe; Kuijpers, Michiel; Bijleveld, Aanke; De Maat, Gijs E; Koene, Bart M; Erasmus, Michiel E; Natour, Ehsan; Mariani, Massimo A
2015-01-01
Training models are essential in mastering the skills required for off-pump coronary artery bypass grafting (OPCAB). We describe a new, high-fidelity, effective and reproducible beating-heart OPCAB training model in human cadavers. Human cadavers were embalmed according to the 'Thiel method' which allows their long-term and repeated use. The training model was constructed by bilateral ligation of the pulmonary veins, cross-clamping of the aorta, positioning of an intra-aortic balloon pump (IABP) in the left ventricle (LV) through the apex (tightened with pledget-reinforced purse strings) and finally placing of a fluid line in the LV through the left atrial appendage (tightened with a pledget-reinforced purse string). The LV was filled with saline to the desired pressure through the fluid line and the IABP was switched on and set to a desired frequency [usually 60-80 beats per minute (bpm)]. A high-fidelity simulation has known limitations, but a more complex, realistic training environment with an actual beating (human) heart strengthens the entire training exercise and is of incremental value. All types of coronary artery anastomosis can be trained with this model. Training should be performed under the supervision of an experienced OPCAB surgeon and training progress is best evaluated with serial Objective Structured Assessment of Technical Skills (OSATS). A score of at least 48 points on the final OSATS ('good' on all components) is recommended before trainees can start their training on patients. The entire set-up provides a versatile training model to help develop and improve the skills required to safely perform beating heart OPCAB anastomoses. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Mumby, S; Koh, T W; Pepper, J R; Gutteridge, J M
2001-11-29
Conventional cardiopulmonary bypass surgery (CCPB) increases the iron loading of plasma transferrin often to a state of plasma iron overload, with the presence of low molecular mass iron. Such iron is a potential risk factor for oxidative stress and microbial virulence. Here we assess 'off-pump' coronary artery surgery on the beating heart for changes in plasma iron chemistry. Seventeen patients undergoing cardiac surgery using the 'Octopus' myocardial wall stabilisation device were monitored at five time points for changes in plasma iron chemistry. This group was further divided into those (n=9) who had one- or two- (n=8) vessel grafts, and compared with eight patients undergoing conventional coronary artery surgery. Patients undergoing beating heart surgery had significantly lower levels of total plasma non-haem iron, and a decreased percentage saturation of their transferrin at all time points compared to conventional bypass patients. Plasma iron overload occurred in only one patient undergoing CCPB. Beating heart surgery appears to decrease red blood cell haemolysis, and tissue damage during the operative procedures and thereby significantly decreases the risk of plasma iron overload associated with conventional bypass.
Liu, Yan; Cui, Hu-jun; Tao, Liang; Chen, Xu-fa
2011-04-01
To analyze the clinical effect of minimal extracorporeal circulation (MECC) in blood conservation perioperatively coronary artery bypass graft (CABG). The data of 120 cases received simple CABG since August 2006 to October 2009 was analyzed retrospectively. All the patients were divided to three groups according to the mode of circulation support in-operation: MECC, conventional extracorporeal circulation (cECC) or off-pump, 40 cases in each group. Jostra MECC system with normal temperature was used in MECC group, and common membrane oxygenator with moderate hypo-temperature was used in cECC group. Collect the data of coagulation and the blood cytological examination perioperatively, the draining volume during the first 24 h after operation, and consumption of blood products perioperatively. Standard and logistic EuroSCORE were higher in MECC group than the others (P < 0.01). The operative time and the number of distal anastomosis of off-pump group were less than MECC and cECC groups (P < 0.05), while no difference between MECC group and cECC group. Intrinsic coagulation (activated partial thromboplastin time) were much more prolonged early postoperatively in cECC group, and higher than in MECC group and off-pump group at 2 h, 6 h and 12 h postoperatively (P < 0.05), but no difference in extrinsic coagulation (prothrombin time) among three group. Adjusted by hematocrit of the same sample, free hemoglobin level rose up during the ECC procedure and reached the maximum at the end of ECC in cECC group and MECC group, but the levels were more higher in cECC group than in MECC group (P < 0.05). The draining volume during the first 24 h after operation of cECC group was larger than MECC group and off-pump group (P < 0.05). Although the decreased platelet count perioperatively and more consumed of the blood products in cECC group, but no difference among the three groups. MECC could reduce the ruin to blood cell and interfere to coagulation function during the conventional ECC procedure, decrease the postoperative draining volume and requirement of blood products.
NASA Technical Reports Server (NTRS)
1975-01-01
A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.
Sileshi, Bantayehu; Haglund, Nicholas A; Davis, Mary E; Tricarico, Nicole M; Stulak, John M; Khalpey, Zain; Danter, Matthew R; Deegan, Robert; Kennedy, Jason; Keebler, Mary E; Maltais, Simon
2015-01-01
Minimally invasive left thoracotomy (MILT) and off-pump implantation strategies have been anecdotally reported for implantation of the HeartWare ventricular assist device (HVAD). We analyzed our experience with off-pump MILT implantation techniques and compared early in-hospital outcomes with conventional on-pump sternotomy (CS) implantation strategy. Between January 2013 and February 2014, 51 patients underwent HVAD implantation and were included in this study. Thirty-three patients had CS, whereas 18 patients underwent off-pump MILT. To compare outcomes of these techniques, a multivariate analysis using propensity score modeling was performed after adjusting for age, INTERMACS, Kormos and Leitz-Miller (LM) scores. Mean age at implant was 57 (range 18 to 69) years, and overall in-hospital mortality was 8%. Univariate analysis revealed a statistically significant reduction in days on inotropes (p = 0.04), and a trend toward reduced intra-operative blood product administration (p = 0.08) in the MILT group. There was no difference in intensive-care-unit length of stay (p = 0.5), total length of stay (p = 0.76), post-operative blood product administration (p = 0.34) and total time on mechanical ventilation (p = 0.32). After adjusting for age, INTERMACS profile and Kormos and LM scores, no statistically significant differences were observed between the MILT and CS groups. An off-pump MILT implantation strategy can be utilized as a safe surgical approach for patients undergoing HVAD implantation. Further large collaborative studies are needed to identify advantages of the MILT approach. Published by Elsevier Inc.
Gandhi, Hemang; Sarvaia, Alpesh; Malhotra, Amber; Acharya, Himanshu; Shah, Komal; Rajavat, Jeevraj
2018-01-01
The prevalence of diabetes mellitus in patients requiring coronary artery bypass grafting (CABG) is noticeably high (20%-30%). These patients have inferior perioperative outcome, reduced long-term survival, and high risk of recurrent episodes of angina. To improve perioperative outcome surgical unit defined satisfactory glycemic control is desired during this period. Hence, the aim of our study is to compare the efficacy of glargine insulin combination with continuous human insulin infusion for perioperative glycemic control in patients with diabetes undergoing CABG. Fifty Patients, who were posted for off-pump CABG with diabetes mellitus type II, were randomized in two group, Group I normal saline + human insulin infusion during the perioperative period, Group II (glargine group): Glargine + human insulin infusion during perioperative period. During surgery and in the postoperative period, random blood sugar and human insulin requirement are significantly higher in control group than glargine group. Other infection, step-up antibiotics, intensive care unit (ICU) stay, and hospital stay were significantly higher in control groups in postoperative period. Our study results suggest that glargine effectively manages blood glucose level with significantly greater control over postoperative morbidity.
Rapid Speed Modulation of a Rotary Total Artificial Heart Impeller.
Kleinheyer, Matthias; Timms, Daniel L; Tansley, Geoffrey D; Nestler, Frank; Greatrex, Nicholas A; Frazier, O Howard; Cohn, William E
2016-09-01
Unlike the earlier reciprocating volume displacement-type pumps, rotary blood pumps (RBPs) typically operate at a constant rotational speed and produce continuous outflow. When RBP technology is used in constructing a total artificial heart (TAH), the pressure waveform that the TAH produces is flat, without the rise and fall associated with a normal arterial pulse. Several studies have suggested that pulseless circulation may impair microcirculatory perfusion and the autoregulatory response and may contribute to adverse events such as gastrointestinal bleeding, arteriovenous malformations, and pump thrombosis. It may therefore be beneficial to attempt to reproduce pulsatile output, similar to that generated by the native heart, by rapidly modulating the speed of an RBP impeller. The choice of an appropriate speed profile and control strategy to generate physiologic waveforms while minimizing power consumption and blood trauma becomes a challenge. In this study, pump operation modes with six different speed profiles using the BiVACOR TAH were evaluated in vitro. These modes were compared with respect to: hemodynamic pulsatility, which was quantified as surplus hemodynamic energy (SHE); maximum rate of change of pressure (dP/dt); pulse power index; and motor power consumption as a function of pulse pressure. The results showed that the evaluated variables underwent different trends in response to changes in the speed profile shape. The findings indicated a possible trade-off between SHE levels and flow rate pulsatility related to the relative systolic duration in the speed profile. Furthermore, none of the evaluated measures was sufficient to fully characterize hemodynamic pulsatility. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Grocott, Hilary P; Mathew, Joseph P; Carver, Elizabeth H; Phillips-Bute, Barbara; Landolfo, Kevin P; Newman, Mark F
2004-02-01
In this trial we compared the hypothermia avoidance abilities of the Arctic Sun Temperature Management System (a servo-regulated system that circulates temperature-controlled water through unique energy transfer pads adherent to the patient's body) with conventional temperature control methods. Patients undergoing off-pump coronary artery bypass (OPCAB) surgery were randomized to either the Arctic Sun System alone (AS group) or conventional methods (control group; increased room temperature, heated IV fluids, convective forced air warming system) for the prevention of hypothermia (defined by a temperature <36 degrees C). The AS group had nasopharyngeal temperature servo-regulated to a target of 36.8 degrees C. Temperature was recorded throughout the operative period and comparisons were made between groups for both the time and area under the curve (AUC) for a temperature <36 degrees C (AUC<36 degrees C). Twenty-nine patients (AS group = 14, control group = 15) were studied. The AS group had significantly less hypothermia than the control group, both for duration of time <36 degrees C (2.5 [0-22] min, median [interquartile range] AS group versus 118 [49-192] min, control group; P = 0.0008) as well as for AUC<36 degrees C (0.3 [0-2.2] degrees C x min, AS group versus 17.1 [3.6-173.4] degrees C x min, control group; P = 0.002). The Arctic Sun Temperature Management System significantly reduced intraoperative hypothermia during OPCAB surgery. Importantly, this was achieved in the absence of any other temperature modulating techniques, including the use of IV fluid warming or increases in the ambient operating room temperature. The Arctic Sun Temperature Management System was more effective than conventional methods in preventing hypothermia during off-pump coronary artery bypass graft surgery.
Kerbaul, F; Giorgi, R; Oddoze, C; Collart, F; Guidon, C; Lejeune, P J; Villacorta, J; Gouin, F
2004-11-01
Procalcitonin (PCT) blood concentrations are known to be an appropriate marker of severe systemic inflammatory response syndrome (SIRS) induced by coronary artery surgery with and without cardiopulmonary bypass. Pro-brain natriuretic peptide (N-BNP) is a newly described cardiac hormone considered to be an effective marker of severity and prognosis of acute coronary syndromes and congestive heart failure. We evaluated the perioperative time courses of PCT and N-BNP and investigated their role as early markers of severe SIRS (SIRS with cardiovascular dysfunction) induced by off-pump coronary artery bypass (OPCAB). Sixty-three patients were prospectively included. The American College of Chest Physicians Classification was used to diagnose SIRS and organ system failure to define severe SIRS. Serum concentrations of PCT and N-BNP were determined before, during and after surgery. Receiver operating characteristic curves and cut-off values were used to assess the ability of these markers to predict postoperative severe SIRS. SIRS occurred in 25 (39%) patients. Nine of them (14%) showed severe SIRS. Significantly higher serum concentrations of N-BNP and PCT were found in patients with severe SIRS with peak concentrations respectively at 8887 pg ml(-1) (range 2940-29372 pg ml(-1)) for N-BNP and 9.50 ng ml(-1) (range 1-65 ng ml(-1)) for PCT. The area under the curve using N-BNP to detect postoperative severe SIRS was 0.799 before surgery (0.408 for PCT; P<0.01) and 0.824 at the end of surgery (0.762 for PCT; P<0.05). N-BNP may be an appropriate marker indicating the early development of non-infectious postoperative severe SIRS after OPCAB.
First report of 90-day support of 2 calves with a continuous-flow total artificial heart.
Karimov, Jamshid H; Moazami, Nader; Kobayashi, Mariko; Sale, Shiva; Such, Kimberly; Byram, Nicole; Sunagawa, Gengo; Horvath, David; Gao, Shengqiang; Kuban, Barry; Golding, Leonard A R; Fukamachi, Kiyotaka
2015-09-01
The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. CFTAH pumps have been implanted in 17 calves total. Hemodynamic parameters, pump performance, and device-related adverse events were evaluated during studies and at necropsy. In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure, 16 ± 3 mm Hg; right atrial pressure, 17 ± 3 mm Hg; right atrial pressure-left atrial pressure difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; and pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three animals with recent CFTAH implantation recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last 2 were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to human surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Australian and New Zealand Perfusion Survey: Equipment and Monitoring
Baker, Robert A.; Willcox, Timothy W.
2006-01-01
Abstract: The current practice of perfusion in Australia and New Zealand continues to adopt new techniques and procedures into clinical practice. Our aims were to report current practice in 2003 and to compare and contrast current practice with historic practice. A total of 62 centers (40 perfusion groups) performing procedures using cardiopulmonary bypass (CPB) were identified and were e-mailed a detailed electronic survey. The survey was comprised of an excel worksheet that contained 233 single answer questions (either dropdown lists, yes/no, true/false, or numeric) and 12 questions that allowed the respondent to provide a commentary. Respondents were instructed to answer all questions based on what represented the predominant practice of perfusion in their institutions during 2003. We report an 89% response rate representing a caseload of 20,688 adult cases. These data allowed us to profile the following. A standard adult CPB setup in 2003 consisted of a membrane oxygenator (100% of cases), a roller pump (70%) as the main arterial pump, although a centrifugal pump would be considered for selected procedures (30%), a circuit incorporating a hard-shell venous reservoir (86%), and a mixture of biocompatible and nonbiocompatible circuit components (66%). The circuit would include a pre-bypass filter (88%), an arterial line filter (94%), and would allow monitoring of the following: hard-shell venous reservoir low level (100%) with servo-regulation of the arterial pump (85%), microbubble alarm (94%) with servo-regulation of the arterial pump (79.5%), arterial line pressures (100%) with servo-regulation of the arterial pump (79%), inline venous O2 saturation (100%), and inline hematocrit (58%). Perfusion practice in Australia and New Zealand has adopted changes over the last decade; however, some areas of practice show wide variation. This survey provides a baseline of contemporary practice for Australian and New Zealand perfusionists. PMID:17089508
Stevanovic, Ana; Coburn, Mark; Menon, Ares; Rossaint, Rolf; Heyland, Daren; Schälte, Gereon; Werker, Thilo; Wonisch, Willibald; Kiehntopf, Michael; Goetzenich, Andreas; Rex, Steffen; Stoppe, Christian
2014-01-01
Cardiac surgery is accompanied by an increase of oxidative stress, a significantly reduced antioxidant (AOX) capacity, postoperative inflammation, all of which may promote the development of organ dysfunction and an increase in mortality. Selenium is an essential co-factor of various antioxidant enzymes. We hypothesized a less pronounced decrease of circulating selenium levels in patients undergoing off-pump coronary artery bypass (OPCAB) surgery due to less intraoperative oxidative stress. In this prospective randomised, interventional trial, 40 patients scheduled for elective coronary artery bypass grafting were randomly assigned to undergo either on-pump or OPCAB-surgery, if both techniques were feasible for the single patient. Clinical data, myocardial damage assessed by myocard specific creatine kinase isoenzyme (CK-MB), circulating whole blood levels of selenium, oxidative stress assessed by asymmetric dimethylarginine (ADMA) levels, antioxidant capacity determined by glutathionperoxidase (GPx) levels and perioperative inflammation represented by interleukin-6 (IL-6) levels were measured at predefined perioperative time points. At end of surgery, both groups showed a comparable decrease of circulating selenium concentrations. Likewise, levels of oxidative stress and IL-6 were comparable in both groups. Selenium levels correlated with antioxidant capacity (GPx: r = 0.720; p<0.001) and showed a negative correlation to myocardial damage (CK-MB: r = -0.571, p<0.001). Low postoperative selenium levels had a high predictive value for the occurrence of any postoperative complication. OPCAB surgery is not associated with less oxidative stress and a better preservation of the circulating selenium pool than on-pump surgery. Low postoperative selenium levels are predictive for the development of complications. ClinicalTrials.gov NCT01409057.
Off-pump versus on-pump revascularization in females: a meta-analysis of observational studies.
Attaran, S; Harling, L; Ashrafian, H; Moscarelli, M; Casula, R; Anderson, J; Punjabi, P; Athanasiou, T
2014-09-01
Coronary revascularization in female patients presents several challenges, including smaller target vessels and smaller conduits. Furthermore, late presentation and more co-morbidities than males may increase complication rates. The aim of this study was to assess whether off-pump coronary artery bypass (OPCAB) improves outcomes when compared to on-pump coronary artery bypass (ONCAB) in the female population. A systematic literature review identified six observational studies, incorporating 23313 patients (n=9596 OPCAB, 13717 ONCAB). These were meta-analyzed using random effects modeling. Heterogeneity, subgroup analysis, quality scoring and publication bias were assessed. The primary endpoints were 30-day mortality and major cardiac, respiratory and renal complications. Secondary endpoints were the number of grafts per patient. No statistically significant difference was observed in 30-day mortality between the OPCAB and ONCAB groups (4.8% vs. 0.7%; OR 0.96; 95% CI [0.41, 2.24], p=0.92). Significant inter-study heterogeneity was also present (I2=94%) and was not explained by study size or quality. Peri-operative myocardial infarction (OR 0.65; 95% CI [0.51, 0.84], p=0.0009) was significantly lower with OPCAB without significant heterogeneity; however, OPCAB did not significantly alter other morbidity outcomes. OPCAB was associated with a trend towards fewer grafts per patient than ONCAB. OPCAB is a safe alternative to ONCAB in the surgical revascularisation of female patients and may reduce post-operative myocardial infarction (MI). However, this does not translate into a reduction in 30-day mortality and OPCAB does not significantly improve other cardiovascular, renal or neurological outcomes. Late outcome data remains lacking and a well-structured, randomized trial is required to answer vital questions regarding the effect of OPCAB on women in the long-term. © The Author(s) 2014.
Mazzone, Annette L; Baker, Robert A; McNicholas, Kym; Woodman, Richard J; Michael, Michael Z; Gleadle, Jonathan M
2018-03-01
A pilot study to measure and compare blood and urine microRNAs miR-210 and miR-16 in patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and off-pump coronary artery bypass grafting surgery. Frequent serial blood and urine samples were taken from patients undergoing cardiac surgery with CPB (n = 10) and undergoing off-pump cardiac surgery (n = 5) before, during, and after surgery. Circulating miR-210 and miR-16 levels were determined by relative quantification real-time polymerase chain reaction. Levels of plasma-free haemoglobin (fHb), troponin-T, creatine kinase, and creatinine were measured. Perioperative serum miR-210 and miR-16 were elevated significantly compared to preoperative levels in patients undergoing cardiac surgery with CPB (CPB vs. Pre Op and Rewarm vs. Pre Op; p < .05 for both). There were increases of greater than 200% in miR-210 levels during rewarming and immediately postoperatively and a 3,000% increase in miR-16 levels immediately postoperatively in urine normalized to urinary creatinine concentration. Serum levels of miR-16 were relatively constant during off-pump surgery. miR-210 levels increased significantly in off-pump patients perioperatively ( p < .05 Octopus on vs. Pre Op); however, the release was less marked when compared to cardiac surgery with CPB. A significant association was observed between both miR-16 and miR-210 and plasma fHb when CPB was used ( r = -.549, p < .0001 and r = -.463, p < .0001 respectively). Serum and urine concentrations of hypoxically regulated miR-210 and hemolysis-associated miR-16 increased in cardiac surgery using CPB compared to off-pump surgery. These molecules may have utility in indicating severity of cardiac, red cell, and renal injury during cardiac surgery.
Menasché, P
2001-12-01
There is compelling evidence that off-pump coronary artery bypass operations are associated with reduced circulating levels of inflammatory mediators. Whereas complement activation and release of acute-phase reactants such as interleukin-6 are still expected to occur as consequences of a nonbypass-related general surgical trauma, a major feature of off-pump surgery seems to be a decreased production of interleukin-8, which may have important practical implications because of the participation of this cytokine in neutrophil trafficking and myocardial injury. The scarcity of carefully controlled, randomized trials precludes firm conclusions regarding the extent to which these biological changes translate into meaningful improvements in clinical outcomes. The problem is further complicated by the fact that the adverse effects of cardiopulmonary bypass largely depend on a genetically controlled balance between proinflammatory and antiinflammatory mediators. Currently, it is still impossible to predict, in a given patient, the side toward which this balance will be shifted. Nevertheless, accumulating experience identifies patient subgroups who may greatly benefit from avoiding extracorporeal circulation. These subsets include patients with severe extracardiac comorbidities (in particular, renal failure) and, possibly, patients with advanced left ventricular dysfunction, who may poorly tolerate superimposed, bypass-related, inflammatory tissue injuries.
Bauer, Adrian; Schaarschmidt, Jan; Grosse, F Oliver; Al Alam, Nidal; Hausmann, Harald; Krämer, Klaus; Strüber, Martin; Mohr, Friedrich W
2014-06-01
The use of extracorporeal life support systems (ECLS) in patients with postcardiotomy low cardiac output syndrome (LCO) as a bridge to recovery and bridge to implantation of ventricular assist device (VAD) is common nowadays. A 59-year-old patient with acute myocardial infarction received a percutaneous transluminal angioplasty and stenting of the circumflex artery. During catheterization of the left coronary artery (LAD), the patient showed ventricular fibrillation and required defibrillation and cardiopulmonary resuscitation. After implantation of an intra-aortic balloon pump, the patient immediately was transmitted to the operating room. He received emergency coronary artery bypass grafting in a beating heart technique using pump-assisted minimal extracorporeal circulation circuit (MECC). Two bypass grafts were performed to the LAD and the right posterior descending artery. Despite initial successful weaning off cardiopulmonary bypass with high-dose inotropic support, the patient presented postcardiotomy LCO and an ECLS was implanted. The primary setup of the heparin-coated MECC system was modified and used postoperatively. As a result of the absence of an in-house VAD program, the patient was switched to a transportable ECLS the next day and was transferred by helicopter to the nearest VAD center where the patient received a successful insertion of a left VAD 3 days later.
Advantages of autologous blood transfusion in off-pump coronary artery bypass.
Ela, Yuksel; Emmiler, Mustafa; Kocogullari, Cevdet Ugur; Terzi, Yuksel; Sivaci, Remziye Gul; Cekirdekci, Ahmet
2009-10-01
In this randomized controlled study, we investigated the effects of autologous Hemobag blood transfusion (AHBT) and allogenic blood transfusion (ABT) in off-pump coronary artery bypass (OPCAB) surgery. Sixty patients who underwent surgery between February 2008 and August 2008 were randomized into 2 groups. The AHBT group (n = 30) consisted of patients who received autologous Hemobag blood transfusion, and the ABT group (n = 30) consisted of patients who received allogenic blood transfusion. All patients underwent OPCAB via sternotomy. The time to extubation, chest tube drainage volume, postoperative white blood cell counts, amount of blood transfusion, sedimentation rate, C-reactive protein concentration, postoperative temperature, and the presence of atelectasis were recorded in the intensive care unit. Intraoperative bleeding and fluid resuscitation were similar in the 2 groups (P > .05); however, there were significant decreases in postoperative blood loss, extubation period, postoperative white cell counts, sedimentation rate, incidence of atelectasis, C-reactive protein, and fever in the AHBT group compared with the ABT group (P < .05). The rate of atrial fibrillation in the AHBT group tended to be lower than in the ABT group. Autologous blood transfusion in OPCAB may be beneficial in certain cardiac surgery patients; however, these beneficial effects require further study to be proved.
Totally normothermic aortic arch replacement without circulatory arrest.
Touati, Gilles D; Marticho, Paul; Farag, Moataz; Carmi, Doron; Szymanski, Catherine; Barry, Misbaou; Trojette, Faouzi; Caus, Thierry
2007-08-01
Various techniques have been proposed for cerebral protection during the surgical treatment of complex aortic disease. The authors propose a revisited strategy of normothermic replacement of the aortic arch to avoid limitations and complications of profound hypothermic circulatory arrest. From April 2000 to May 2006, 19 patients with an aneurysm of the aortic arch and 10 patients with an acute (7) or a chronic (3) aortic dissection underwent a totally normothermic, complete replacement of the aortic arch using three pumps: One pump ensured antegrade cerebral perfusion, at a flow rate adapted to obtain a pressure of 70 mmHg in the right radial artery, and required a selective cannulation of the supra-aortic vessels. A second pump ensured body perfusion at a flow rate adapted to obtain a pressure of 55 mmHg in the left femoral artery and was situated between the right femoral artery and the right atrium. A special balloon aortic occlusion catheter was placed in the descending thoracic aorta. A third pump ensured intermittent normothermic myocardial perfusion via the coronary venous sinus. The arch reconstruction was performed with no time limit. There were two operative, in-hospital (6.8%) mortalities. All others patients were rapidly extubated, except one, with no neurological sequelae, and postoperative course was uneventful, without coagulopathy or hepato-renal impairment. In the light of these results, a normothermic procedure is possible for arch surgery and may ensure a more physiological autoregulation of cerebral blood flow while maintaining body perfusion without high vascular resistances.
Angiographic flow grading and graft arrangement of arterial conduits.
Nakajima, Hiroyuki; Kobayashi, Junjiro; Tagusari, Osamu; Niwaya, Kazuo; Funatsu, Toshihiro; Kawamura, Atsushi; Yagihara, Toshikatsu; Kitamura, Soichiro
2006-11-01
We sought to delineate the effects of competitive and reverse flow on the intermediate-term patency of arterial conduits and examined graft arrangements for maximizing antegrade bypass flow. The angiograms of 2083 bypass grafts in 570 patients who underwent off-pump total arterial revascularization without aortic manipulation since December 2000 were reviewed. The blood flow in the bypass grafts were graded A (antegrade), B (competitive), C (reverse), or O (occlusion). The mean number of distal anastomoses was 3.65 +/- 0.94 per patient. In the early angiography 91.3% (1901/2083) of the bypasses were grade A. Thirty (1.4%) bypasses were grade O, whereas 2.9% (61/2083) were grade B, and 4.4%(91/2083) were grade C. In the multivariate analysis the end-to-side anastomosis (P < .0001), 4 or more distal anastomoses of the conduit (P = .01), native coronary stenosis of less than 75% (P < .0001), and target branch location of the right coronary artery territory (P < .0001) and left circumflex artery territory (P = .02) significantly correlated with grade non-A. The patency rate in the late angiography of the bypasses graded B or C in the early angiography was 7 (28.0%) of 25, whereas that of the bypasses graded A was 164 (89.1%) of 184 (P < .0001). The actuarial graft patency rate of the bypasses graded A was 72.3% at 3 years and was significantly higher than that of the bypasses graded B or C (28.6% at 3 years after surgical intervention, P < .0001). The sufficient antegrade bypass flow had a favorable effect on the graft patency of arterial conduits. The graft arrangement should be adjusted for each patient so as to maximize the antegrade bypass flow and to confirm the advantage of arterial grafts.
Hynes, Conor F; Colo, Sanchez; Amdur, Richard L; Chawla, Lakhmir S; Greenberg, Michael D; Trachiotis, Gregory D
2016-01-01
This study aimed to evaluate the short- and long-term effects of conventional on-pump coronary bypass grafting (cCABG) compared with off-pump coronary artery bypass (OPCAB) on renal function. A retrospective review of patients undergoing coronary bypass grafting from 2004 through 2013 at a single center was conducted. Preoperative renal function, perioperative acute kidney injury, and long-term glomerular filtration were evaluated. Multivariable analyses were used to determine factors contributing to short- and long-term renal impairment. A total of 234 patients underwent cCABG, and 582 underwent OPCAB. Patients undergoing OPCAB were significantly older, had greater preoperative renal dysfunction, had greater functional dependence, and took more hypertension medications. Multivariable analyses found that 30-day acute kidney injury was an independent risk factor for a 10% decline in glomerular filtration rate at 1 and 5 years (P < 0.0001 and 0.002, respectively). However, the use of cardiopulmonary bypass was not found to influence long-term renal function (P = 0.78 at 1 year, P = 0.76 at 5 years). The percentage of patients experiencing a 10% drop in renal function from baseline at 1 year (33% OPCAB, 35% cCABG; P = 0.73) and 5 years (16% OPCAB, 16% cCABG; P = 0.93) were not significantly different. Independent predictors of acute kidney injury included baseline kidney function (P = 0.04) and age (P < 0.0001), whereas cardiopulmonary bypass did not affect the incidence (P = 0.17). A propensity-matched analysis confirmed these findings. Acute kidney injury is a risk factor for long-term renal dysfunction after either bypass method and was not greater after cCABG compared with OPCAB. Patients undergoing OPCAB did not experience greater decrease in long-term kidney function despite having worse baseline kidney function.
Krzysztof, Szwed; Wojciech, Pawliszak; Zbigniew, Serafin; Mariusz, Kowalewski; Remigiusz, Tomczyk; Damian, Perlinski; Magdalena, Szwed; Marta, Tomaszewska; Lech, Anisimowicz; Alina, Borkowska
2017-07-10
Neurological injuries remain a major concern following coronary artery bypass grafting (CABG) that offsets survival benefit of CABG over percutaneous coronary interventions. Among numerous efforts to combat this issue is the development of off-pump CABG (OPCABG) that obviates the need for extracorporeal circulation and is associated with improved neurological outcomes. The objective of this study is to examine whether the neuroprotective effect of OPCABG can be further pronounced by the use of two state-of-the-art operating techniques. In this randomised, controlled, investigator and patient blinded single-centre superiority trial with three parallel arms, a total of 360 patients will be recruited. They will be allocated in a 1:1:1 ratio to two treatment arms and one control arm. Treatment arms undergoing either aortic no-touch OPCABG or OPCABG with partial clamp applying carbon dioxide surgical field flooding will be compared against control arm undergoing OPCABG with partial clamp. The primary endpoint will be the appearance of new lesions on control brain MRI 3 days after surgery. Secondary endpoints will include the prevalence of new focal neurological deficits in the first 7 days after surgery, the occurrence of postoperative cognitive dysfunction at either 1 week or 3 months after surgery and the incidence of delirium in the first 7 days after surgery. Data will be analysed on intention-to-treat principles and a per protocol basis. Ethical approval has been granted for this study. Results will be disseminated through peer-reviewed media. NCT03074604; Pre-results. 10-Mar-2017 Original. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Pilarczyk, Kevin; Boening, Andreas; Jakob, Heinz; Langebartels, Georg; Markewitz, Andreas; Haake, Nils; Heringlake, Matthias; Trummer, Georg
2016-01-01
In contrast to the results of previous studies, recent randomized controlled trials (RCTs) failed to show a benefit of prophylactic aortic counterpulsation in high-risk patients undergoing cardiac surgery. The present analysis aims to redefine the effects of this treatment modality in the light of this new evidence. MEDLINE, EMBASE, CENTRAL/CCTR, Google Scholar and reference lists of relevant articles were searched for full-text articles of RCTs in English or German. Assessments for eligibility, relevance, study validity and data extraction were performed by two reviewers independently using prespecified criteria. The primary outcome was hospital mortality. A total of nine eligible RCTs with 1171 patients were identified: 577 patients were treated preoperatively with intra-aortic balloon pump (IABP) and 594 patients served as controls. The pooled odds ratio (OR) for hospital mortality (22 hospital deaths in the intervention arm, 54 in the control group) was 0.381 (95% CI 0.230-0.629; P < 0.001). The pooled analyses of five RCTs including only patients undergoing isolated on-pump coronary artery bypass grafting (n[IABP] = 348, n[control] = 347) also showed a statistically significant improvement in mortality for preoperative IABP implantation (fixed-effects model: OR 0.267, 95% CI 0.129-0.552, P < 0.001). The pooled OR for hospital mortality from two randomized off-pump trials was 0.556 (fixed-effects model, 95% CI 0.207-1.493, P = 0.226). Preoperative aortic counterpulsation was associated with a significant reduction in low cardiac output syndrome (LCOS) in the total population (fixed-effects model: OR 0.330, 95% CI 0.214-0.508, P < 0.001) as well as in the subgroup of CAGB patients (fixed-effects model: OR 0.113, 95% CI 0.056-0.226, P < 0.001), whereas there was no benefit in the off-pump population (fixed-effects model: OR 0.555, 95% CI 0.209-1.474, P = 0.238). Preoperative IABP implantation was associated with a reduction of intensive care unit (ICU) stay in all investigated populations with a greater effect in the total population [fixed-effects model: standard mean difference (SMD) -0.931 ± 0.198, P < 0.001] as well as in the subgroup of CAGB patients (fixed-effects model: SMD -1.240 ± 0.156, P < 0.001), compared with the off-pump group (fixed-effects model: SMD -0.723 ± 0.128, P < 0.001). Despite contradictory results from recent trials, the present study confirms the findings of previous meta-analyses that prophylactic aortic counterpulsation reduces hospital mortality, incidence of LCOS and ICU requirement in high-risk patients undergoing on-pump cardiac surgery. However, owing to small sample sizes and the lack of a clear-cut definition of high-risk patients, an adequately powered, prospective RCT is necessary to find a definite answer to the question, if certain groups of patients undergoing cardiac surgery benefit from a prophylactic IABP insertion. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Jelenc, Matija; Kneževič, Ivan; Stankovič, Milenko; Geršak, Borut
2012-01-01
We present a case of a 62-year old man with a left main stenosis, left coronary artery dominance, normal ejection fraction and no valvular pathology, and status post right carotid artery stenting, who was scheduled for elective coronary revascularization. We performed off-pump coronary revascularization, anastomosing the left internal thoracic artery to the left anterior descending artery, and three separate saphenous vein grafts to the intermediate artery and the first and second obtuse marginals, respectively. Proximally, the right internal thoracic artery was used as the inflow for all three venous grafts due to a heavily calcified ascending aorta. During the construction of the distal anastomoses to the obtuse marginals, the arterial pressure in the left radial artery suddenly dropped. The left hand was found to be pale and pulseless. A femoral artery catheter was placed for pressure monitoring and the anastomoses were completed as planned. Intraoperative transit-time graft flow measurement showed a reversed flow in the left internal thoracic artery. Postoperatively, angiography was performed showing a subtotal stenosis of the proximal left subclavian artery. The artery was dilated and stented. The postoperative course was uneventful and the patient was discharged on the 12th postoperative day. PMID:22767542
Likhvantsev, Valery V; Landoni, Giovanni; Grebenchikov, Oleg A; Skripkin, Yuri V; Zabelina, Tatiana S; Zinovkina, Liudmila A; Prikhodko, Anastasia S; Lomivorotov, Vladimir V; Zinovkin, Roman A
2017-12-01
To measure the release of plasma nuclear deoxyribonucleic acid (DNA) and to assess the relationship between nuclear DNA level and acute kidney injury occurrence in patients undergoing cardiac surgery. Cardiovascular anesthesiology and intensive care unit of a large tertiary-care university hospital. Prospective observational study. Fifty adult patients undergoing cardiac surgery. Nuclear DNA concentration was measured in the plasma. The relationship between the level of nuclear DNA and the incidence of acute kidney injury after coronary artery bypass grafting was investigated. Cardiac surgery leads to significant increase in plasma nuclear DNA with peak levels 12 hours after surgery (median [interquartile range] 7.0 [9.6-22.5] µg/mL). No difference was observed between off-pump and on-pump surgical techniques. Nuclear DNA was the only predictor of acute kidney injury between baseline and early postoperative risk factors. The authors found an increase of nuclear DNA in the plasma of patients who had undergone coronary artery bypass grafting, with a peak after 12 hours and an association of nuclear DNA with postoperative acute kidney injury. Copyright © 2017 Elsevier Inc. All rights reserved.
Jet pump assisted arterial heat pipe
NASA Technical Reports Server (NTRS)
Bienert, W. B.; Ducao, A. S.; Trimmer, D. S.
1978-01-01
This paper discusses the concept of an arterial heat pipe with a capillary driven jet pump. The jet pump generates a suction which pumps vapor and noncondensible gas from the artery. The suction also forces liquid into the artery and maintains it in a primed condition. A theoretical model was developed which predicts the existence of two stable ranges. Up to a certain tilt the artery will prime by itself once a heat load is applied to the heat pipe. At higher tilts, the jet pump can maintain the artery in a primed condition but self-priming is not possible. A prototype heat pipe was tested which self-primed up to a tilt of 1.9 cm, with a heat load of 500 watts. The heat pipe continued to prime reliably when operated as a VCHP, i.e., after a large amount of noncondensible gas was introduced.
Coronary Endarterectomy: Recent Trends.
Ghatanatti, Ravi; Teli, Anita
2017-08-01
Coronary Endarterectomy (CE) assures complete revascularization of the myocardium in case of diffusely diseased vessels and prevents residual ischemia. Recently cardiac surgeons are performing increasing number of coronary endarterectomy and it has evolved as an important adjuvant procedure in Coronary Artery Bypass Grafting (CABG). There are controversies regarding the efficiency of CE. CE is criticised for its higher rates of morbidity and mortality. At present the available evidence supports CE in Off Pump Coronary Artery Bypass surgery (OPCAB) and along with valvular procedures. Graft patency is better with open technique. Postoperative anticoagulation regimen though not uniform, the overall outcome remains the same. Therefore, it is important to focus on the current results to accept CE as a routine procedure like CABG.
Reoma, Junewai L.; Rojas, Alvaro; Krause, Eric M.; Obeid, Nabeel R.; Lafayette, Nathan G.; Pohlmann, Joshua R.; Padiyar, Niru P.; Punch, Jeffery D; Cook, Keith E.; Bartlett, Robert H
2009-01-01
Extracorporeal cardiopulmonary support(ECS) of donors following cardiac death(DCD) has been shown to improve abdominal organs for transplantation. This study assesses whether pulmonary congestion occurs during ECS with the heart arrested and describes an in-vivo method to assess if lungs are suitable for transplantation from DCD donors following ECS resuscitation. Cardiac arrest was induced in 30 kg pigs, followed by 10min. of warm ischemia. Cannulas were placed into right atrium (RA) and iliac artery, and veno-arterial ECS was initiated for 90min with lungs inflated, Group 1 (n=5) or deflated Group 2 (n=3). Left atrial pressures were measured as a marker for pulmonary congestion. After 90 min of ECS, lung function was evaluated. Cannulae were placed into the pulmonary artery (PA) and left ventricle (LV). A second pump was included, and ECS was converted to a bi-VAD system. The RVAD drained from the RA and pumped into the PA, and the LVAD drained the LV and pumped into the iliac. This brought the lungs back into circulation for a 1hr assessment period. The oxygenator was turned off, and ventilation restarted. Flows, blood gases, pulmonary artery and left atrial pressures, and compliance were recorded. In both groups: LA pressure was <15mmHg during ECS. During the lung assessment period, PA flows were 1.4−2.2 liter/min. PO2 was >300mmHg, with normal PCO2. ECS resuscitation of DCD donors is feasible and allows for assessment of function prior to procurement. ECS does not cause pulmonary congestion, and lungs retain adequate function for transplantation. Compliance correlated with lung function. PMID:19506464
Traumatic Tricuspid Regurgitation Following Cardiac Massage
Na, Sungwon; Nam, Sang Beom; Lee, Yong Kyung; Oh, Young Jun
2007-01-01
We report a 66-yr-old male patient who developed tricuspid regurgitation secondary to internal cardiac massage. After uneventful off-pump coronary artery bypass surgery, the subject experienced cardiac arrest in the intensive care unit. External cardiac massage was initiated and internal cardiac massage was performed eventually. A transesophageal echocardiography revealed avulsion of the anterior papillary muscle and chordae to the anterior leaflet after successful cardiopulmonary resuscitation. Emergency repair of the papillary muscle was performed under cardiopulmonary bypass. PMID:17728519
Lee, Choon Soo; Yoon, Yeo Sam; Shim, Jae-Kwang; Lim, Hyun Kyoung
2013-12-01
Although compressed gas (CO2) blowers have been used safely to aid accurate grafting during off-pump coronary bypass surgery, hemodynamic collapse due to gas embolism into the right coronary artery may occur. Supportive measures to facilitate gas clearance by increasing the coronary perfusion pressure have been reported to be successful in restoring hemodynamic stability. However, right ventricular dysfunction and atrioventricular nodal ischemia may hinder effective systemic delivery of the vasoactive medications, even when performing resuscitative measures such as direct cardiac massage. We herein report a case of cardiac arrest that was caused by a right coronary gas embolism and that could not be restored by cardiac resuscitation. When supportive measures fail, direct aortic injection of epinephrine to increase the coronary perfusion pressure can be attempted before initiating cardiopulmonary bypass, and this approach may be life-saving in situations that limit systemic drug delivery from the venous side despite the performance of direct cardiac massage.
Lee, Choon Soo; Yoon, Yeo Sam; Shim, Jae-Kwang
2013-01-01
Although compressed gas (CO2) blowers have been used safely to aid accurate grafting during off-pump coronary bypass surgery, hemodynamic collapse due to gas embolism into the right coronary artery may occur. Supportive measures to facilitate gas clearance by increasing the coronary perfusion pressure have been reported to be successful in restoring hemodynamic stability. However, right ventricular dysfunction and atrioventricular nodal ischemia may hinder effective systemic delivery of the vasoactive medications, even when performing resuscitative measures such as direct cardiac massage. We herein report a case of cardiac arrest that was caused by a right coronary gas embolism and that could not be restored by cardiac resuscitation. When supportive measures fail, direct aortic injection of epinephrine to increase the coronary perfusion pressure can be attempted before initiating cardiopulmonary bypass, and this approach may be life-saving in situations that limit systemic drug delivery from the venous side despite the performance of direct cardiac massage. PMID:24427464
Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery.
Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari
2017-06-15
A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR.
The CentriMag: a new optimized centrifugal blood pump with levitating impeller.
Mueller, Juerg Peter; Kuenzli, Andreas; Reuthebuch, Oliver; Dasse, Kurt; Kent, Stella; Zuend, Gregor; Turina, Marko Ivan; Lachat, Mario Louis
2004-01-01
Blood pumps are routinely used for circulatory and pulmonary support. However, blood trauma and pump failure remain severe drawbacks of currently available pump models. This study evaluated the first clinical application of a new, totally bearingless centrifugal blood pump (CentriMag). A centrifugal pump consisting of an electromagnetic suspended impeller was used as a blood pump during beating-heart coronary artery bypass grafting in 11 patients (mean weight, 77.4 kg). Heparin in a bolus of 150 IU/kg body weight was administered, and activated clotting time was maintained at approximately 180 to 250 seconds during extracorporeal circulation. Pump-induced blood trauma was evaluated by measurement of plasma free hemoglobin (PFH), lactate dehydrogenase (LDH), hematocrit, total bilirubin, and platelet levels. Mean pump flow was 3.3 +/- 0.62 L/min, and mean pressure gradient through the oxygenator was 69 +/- 4 mm Hg. No pump dysfunction occurred during a mean application time of 105 +/- 26 minutes. Inspection of the pump housings showed no internal thrombus formation despite low-dose heparinization. Only slight hemolysis was observed with a mean PFH level of 1.96 micromol/L; LDH, 460 U/L; hematocrit, 33%; total bilirubin, 25 micromol/L; and platelets, 191 x 10(3)/microL. The bearingless CentriMag blood pump is a safe and reliable new device that produces only minimal hemolysis. It seems to be suited for long-term evaluation as a blood pump for extracorporeal membrane oxygenation or as ventricular assist device.
Chen, Ling; Song, Hong; Wang, Youhua; Lee, Jane C; Kotlikoff, Michael I; Pritchard, Tracy J; Paul, Richard J; Zhang, Jin; Blaustein, Mordecai P
2015-09-01
Arterial myocytes express α1-catalytic subunit isoform Na(+) pumps (75-80% of total), which are ouabain resistant in rodents, and high ouabain affinity α2-Na(+) pumps. Mice with globally reduced α2-pumps (but not α1-pumps), mice with mutant ouabain-resistant α2-pumps, and mice with a smooth muscle (SM)-specific α2-transgene (α2 (SM-Tg)) that induces overexpression all have altered blood pressure (BP) phenotypes. We generated α2 (SM-DN) mice with SM-specific α2 (not α1) reduction (>50%) using nonfunctional dominant negative (DN) α2. We compared α2 (SM-DN) and α2 (SM-Tg) mice to controls to determine how arterial SM α2-pumps affect vasoconstriction and BP. α2 (SM-DN) mice had elevated basal mean BP (mean BP by telemetry: 117 ± 4 vs. 106 ± 1 mmHg, n = 7/7, P < 0.01) and enhanced BP responses to chronic ANG II infusion (240 ng·kg(-1)·min(-1)) and high (6%) NaCl. Several arterial Ca(2+) transporters, including Na(+)/Ca(2+) exchanger 1 (NCX1) and sarcoplasmic reticulum and plasma membrane Ca(2+) pumps [sarco(endo)plasmic reticulum Ca(2+)-ATPase 2 (SERCA2) and plasma membrane Ca(2+)-ATPase 1 (PMCA1)], were also reduced (>50%). α2 (SM-DN) mouse isolated small arteries had reduced myogenic reactivity, perhaps because of reduced Ca(2+) transporter expression. In contrast, α2 (SM-Tg) mouse aortas overexpressed α2 (>2-fold), NCX1, SERCA2, and PMCA1 (43). α2 (SM-Tg) mice had reduced basal mean BP (104 ± 1 vs. 109 ± 2 mmHg, n = 15/9, P < 0.02) and attenuated BP responses to chronic ANG II (300-400 ng·kg(-1)·min(-1)) with or without 2% NaCl but normal myogenic reactivity. NCX1 expression was inversely related to basal BP in SM-α2 engineered mice but was directly related in SM-NCX1 engineered mice. NCX1, which usually mediates arterial Ca(2+) entry, and α2-Na(+) pumps colocalize at plasma membrane-sarcoplasmic reticulum junctions and functionally couple via the local Na(+) gradient to help regulate cell Ca(2+). Altered Ca(2+) transporter expression in SM-α2 engineered mice apparently compensates to minimize Ca(2+) overload (α2 (SM-DN)) or depletion (α2 (SM-Tg)) and attenuate BP changes. In contrast, Ca(2+) transporter upregulation, observed in many rodent hypertension models, should enhance Ca(2+) entry and signaling and contribute significantly to BP elevation. Copyright © 2015 the American Physiological Society.
Minimally invasive direct coronary artery bypass versus off-pump coronary surgery through sternotomy
Birla, R; Patel, P; Aresu, G
2013-01-01
Introduction Although it is not a new technique, minimally invasive direct coronary artery bypass (MIDCAB) is employed only by a few surgeons in the UK. We compared our experience with MIDCAB with that of single vessel off-pump coronary artery bypass (OPCAB) graft surgery through a standard median sternotomy. Methods Patients who underwent either MIDCAB or OPCAB between April 2008 and July 2011 were reviewed. Exclusion criteria included patients with an ejection fraction of <0.5 or previous cardiac surgery. Data were obtained retrospectively from our prospective database, medical records and through general practitioners. Results Overall, 74 patients were analysed in the MIDCAB group and 78 in the OPCAB group. Their demographics and EuroSCORE (European System for Cardiac Operative Risk Evaluation) values were comparable (p>0.05). There was no statistically significant difference in the two groups in terms of mortality, recurrent myocardial infarction, postoperative stroke, wound infection, atrial fibrillation or need for reintervention. The MIDCAB group had six conversions to a sternotomy. Eight patients in each group required blood transfusion, with the average transfusion being 1.8 units in the MIDCAB group and 3.2 units in the OPCAB group. The mean duration of ventilation and intensive care unit stay was 5.0 hours and 38.4 hours in the MIDCAB group and 5.4 and 47.8 hours in the OPCAB group. The mean hospital stay was significantly reduced in the MIDCAB population (6.1 vs 8.5 days, p<0.05). Conclusions MIDCAB can be performed safely in appropriately selected patients with outcomes comparable with OPCAB. The potential benefits include shorter hospital stay, reduced need for blood transfusion and faster recovery. PMID:24112493
Lee, Jiwon; Jung, Chul-Woo; Jeon, Yunseok; Kim, Tae Kyong; Cho, Youn Joung; Koo, Chang-Hoon; Choi, Yoon Hyeong; Kim, Ki-Bong; Hwang, Ho Young; Kim, Hang-Rae; Park, Ji-Young
2017-01-01
The benefit of aspirin use after coronary artery bypass graft surgery has been well proven. However, the effect of preoperative aspirin use in patients undergoing off-pump coronary artery bypass graft surgery (OPCAB) has not been evaluated sufficiently. To evaluate platelet function changes during OPCAB due to preoperative aspirin use, we conducted a randomized controlled trial using flow cytometry and the Multiplate® analyzer. Forty-eight patients scheduled for elective OPCAB were randomized to the aspirin continuation (100 mg/day until operative day) and discontinuation (4 days before the operative day) groups. Platelet function was measured using the platelet activation markers CD62P, CD63, and PAC-1 by flow cytometry, and platelet aggregation was measured using the Multiplate® analyzer, after the induction of anesthesia (baseline), at the end of the operation, and 24 and 48 h postoperatively. Findings of conventional coagulation assays, thromboelastography by ROTEM® assays, and postoperative bleeding-related clinical outcomes were compared between groups. No significant change in CD62P, CD63, or PAC-1 was observed at the end of the operation or 24 or 48 h postoperatively compared with baseline in either group. The area under the curve for arachidonic acid-stimulated platelet aggregation, measured by the Multiplate® analyzer, was significantly smaller in the aspirin continuation group (P < 0.01). However, chest tube drainage and intraoperative and postoperative transfusion requirements did not differ between groups. Our study showed that preoperative use of aspirin for OPCAB did not affect perioperative platelet activation, but it impaired platelet aggregation, which did not affect postoperative bleeding, by arachidonic acid.
Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery
Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari
2017-01-01
BACKGROUND: A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. METHODS: This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. RESULTS: The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. CONCLUSIONS: Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR. PMID:28698744
Preservation of myocardium during coronary artery bypass surgery.
Kinoshita, Takeshi; Asai, Tohru
2012-08-01
Myocardial protection aims to prevent reversible post-ischemic cardiac dysfunction (myocardial stunning) and irreversible myocardial cell death (myocardial infarction) that occur as a consequence of myocardial ischemia and/or ischemic-reperfusion injury. Although the mortality rate for isolated coronary artery bypass grafting has been markedly reduced during the past decade, myocardial death, as evidenced by elevation in creatine kinase-myocardial band and/or cardiac troponin, is common. This is ascribed to suboptimal myocardial protection during cardiopulmonary bypass or with off-pump technique, early graft failure, distal embolization, and regional or global myocardial ischemia during surgery. An unmet need in contemporary coronary bypass surgery is to find more effective cardioprotective strategies that have the potential for decreasing the morbidity and mortality associated with suboptimal cardioprotection. In the present review article on myocardial protection in contemporary coronary artery bypass surgery, we attempt to elucidate the clinical problems, summarize the outcomes of selected phase III trials, and introduce new perspectives.
Vilos, Angelos G; Vilos, George A; Hollett-Caines, Jackie; Garvin, Greg; Kozak, Roman; Abu-Rafea, Basim
2014-11-01
To evaluate the efficacy and post-procedural pain associated with uterine artery embolization (UAE) using Gelfoam alone versus Embospheres plus Gelfoam in women with symptomatic uterine fibroids. We conducted a prospective, non-randomized pilot study. Fluoroscopy-guided trans-femoral artery UAE was performed using Gelfoam pledgets alone or Embospheres (500 to 700 mg) plus Gelfoam under conscious sedation and local anaesthesia. This was followed by patient-controlled analgesia (PCA) using a morphine pump overnight. Post-procedural pain was assessed by the mean amount of self-administered morphine delivered by PCA pump (mL) from 0 to 19 hours in each group. The mean volumes of the uterus and the dominant fibroid were calculated by ultrasound at baseline, three months, six months, and 12 months. A total of 17 women participated in the study. Bilateral uterine artery occlusion was performed in eight women using Gelfoam alone, and in nine women using Embosphere + Gelfoam. One woman in the Embosphere + Gelfoam group developed a puncture-site hematoma requiring further intervention one week later. The mean (SD) amount of morphine self-administered by PCA pump at time 0, 1, and 2 hours was 3.4 mg (3.1), 2.9 mg (2.2), and 2.4 mg (3.3) in the Gelfoam-only group and 6.1 mg (3.0), 9.6 mg (7.1), and 5.3 mg (4.4) in the Embosphere + Gelfoam group, respectively. After three hours, the amount of morphine used was equal in both groups. The mean (SD) total dose of morphine used was 29.5 mg (18.6) in the Gelfoam group and 41.1 mg (19.3) in the Embosphere + Gelfoam group (P = 0.228). At 12 months, the reduction in median total uterine volume and median dominant fibroid volume in each group was equal. Clinical outcomes were equivalent after uterine artery embolization using Gelfoam alone versus Gelfoam + Embospheres. Although the amount of immediate post-procedure pain may be less with Gelfoam alone, we could not demonstrate this objectively using morphine use as a measure of pain.
Multiple composite grafts (k, π or double-Y) in coronary artery surgery: a choice or a necessity?
Mannacio, Vito; Cirillo, Plinio; Mannacio, Luigi; Antignano, Anita; Mottola, Michele; Vosa, Carlo
2015-01-01
Composite grafts allow complete arterial revascularization with minimal aortic manipulations. The Y-T configuration supplies all distal branches adequately, whereas it is unclear whether complex composite configurations (K, Π or double-Y) are equally at rest or when challenged by maximal requirements. Forty-seven patients who underwent off-pump coronary artery revascularization by multiple arterial composite grafts (K, Π or double-Y) were retrospectively evaluated. Indication for this surgical option was porcelain aorta or conduit unavailability. Composite systems were evaluated by intraoperative flow measurements and perioperative transthoracic Doppler ultrasonography, 12 months later also by exercise test, sestamibi scintigraphy at rest and during induced hyperaemia and by 64-slice multidetector CT angiography. A total of 141 distal anastomoses were implanted as composite grafts. Perioperative flow measurements and 12-month Doppler ultrasonography were adequate at rest. At stress test, chest pain and/or induced ECG evidence of ischaemia are found in 16 patients (39%). During dipyridamole-induced hyperaemia, single-photon emission computed tomography image revealed that mean summed stress score was 7.2 ± 5.7, summed difference score 5.3 ± 4.2 and coronary flow reserve 1.7 ± 0.2. Multiple composite grafts, albeit adequate at rest, were unable to meet flow requirements during maximal hyperaemia. In daily practice, their use must be not a choice but rather a necessity in those patients without alternative options. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Intra-arterial intervention chemotherapy for sarcoma and cancerous ulcer via an implanted pump.
Liu, Cheng; Cui, Qiu; Guo, Jun; Li, Dingfeng; Zeng, Yanjun
2014-04-01
To observe the efficacy of intra-arterial chemotherapy with subcutaneously implanted pump for soft tissue sarcoma in extremities and cancerous ulcer. 31 patients with ulcerative skin squamous cell carcinoma or sarcoma in extremities who received treatment during the period from July 2003 to November 2011 at our hospital were recruited, including 15 male and 16 female patients, aging between 14 and 83 with average age of 49 years old. 10 patients had tumor in upper extremities and 21 patients in lower extremities. The pathological types of studied cases include 9 cases with skin squamous cell carcinoma, 6 cases with synovial sarcoma, 5 cases with malignant fibrous histiocytoma, 3 cases with liposarcoma, 3 cases with osteosarcoma, 2 cases with malignant melanoma, 2 cases with epidermoid sarcoma, and 1 case with protuberans. The main symptoms of cancerous ulcer were pain, infection and hemorrhage; All the studied patients were administrated with cisplatin and doxorubicin by intra-arterial chemotherapy pump, and the patients with squamous cell carcinoma were additionally applied with bleomycin and patients with malignant melanoma were additionally applied with dacarbazine. The chemotherapy efficiency was observed after at 3 cycles of intra-arterial chemotherapy. The total remission rate of pain (RR) was 87 %, and total remission rate of ulcer cicatrization (RR) was 71 %, with ulcer cicatrizing spontaneously in 9 cases and obvious homeostasis in 5 cases with bleeding ulcers. 19 patients underwent surgery after chemotherapy, in which 16 cases had limb-salvage surgery and 3 cases underwent lower leg amputation after chemotherapy, and 3 patients out of 16 cases had local recurrence (19 %). The subcutaneous intra-arterial targeting chemotherapy could be applied to treat refractory sarcoma and cancerous ulcer in extremities to significantly increase the chemotherapeutic concentration at tumor area so as to effectively constrain the tumor rupture induced main symptoms including pain, infection and bleeding, which would help to make a decreased blood supplied and well defined tumor boundary to finally decrease the recurrence rate.
Fukamachi, Kiyotaka; Karimov, Jamshid H; Sunagawa, Gengo; Horvath, David J; Byram, Nicole; Kuban, Barry D; Dessoffy, Raymond; Sale, Shiva; Golding, Leonard A R; Moazami, Nader
2017-12-01
The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.
Shinjo, Daisuke; Fushimi, Kiyohide
2015-11-17
To determine the effect of preoperative patient and hospital factors on resource use, cost and length of stay (LOS) among patients undergoing off-pump coronary artery bypass grafting (OPCAB). Observational retrospective study. Data from the Japanese Administrative Database. Patients who underwent isolated, elective OPCAB between April 2011 and March 2012. The primary outcomes of this study were inpatient cost and LOS associated with OPCAB. A two-level hierarchical linear model was used to examine the effects of patient and hospital characteristics on inpatient costs and LOS. The independent variables were patient and hospital factors. We identified 2491 patients who underwent OPCAB at 268 hospitals. The mean cost of OPCAB was $40 665 ±7774, and the mean LOS was 23.4±8.2 days. The study found that select patient factors and certain comorbidities were associated with a high cost and long LOS. A high hospital OPCAB volume was associated with a low cost (-6.6%; p=0.024) as well as a short LOS (-17.6%, p<0.001). The hospital OPCAB volume is associated with efficient resource use. The findings of the present study indicate the need to focus on hospital elective OPCAB volume in Japan in order to improve cost and LOS. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Nierich, A P; Diephuis, J; Jansen, E W; van Dijk, D; Lahpor, J R; Borst, C; Knape, J T
1999-04-01
To describe hemodynamic alterations during coronary artery bypass grafting (CABG) without extracorporeal circulation using the Octopus Tissue Stabilizer, and to describe the two anesthetic management protocols based on either general anesthesia with opioids (34 patients) or general anesthesia with high thoracic epidural anesthesia (TEA; 66 patients). A prospective observational report. An academic university heart center. First 100 patients undergoing CABG using the Octopus Tissue Stabilizer. None. Current management provided satisfactory results in preventing hypoperfusion of the heart and inadequate systemic circulation without the use of major pharmacologic interventions. Movement of the heart to reach the target site of anastomosis caused hemodynamic alterations. These could easily be corrected by anesthetic interventions, such as fluid load and low doses of inotropes. High TEA allows earlier extubation compared with the opioid anesthesia technique (0.9 v 4.5 hours). Perioperative management and the incidence of postoperative complications did not differ between anesthetic techniques. Major complications, such as death, intraoperative myocardial infarction, and stroke, did not occur. Both anesthetic protocols are safe and effective in handling these patients. Off-pump CABG surgery requires anesthetic interventions because hemodynamic alterations are caused by the presentation of the heart to the surgeon. The complication rate is low but needs to be evaluated, compared with conventional CABG, in a prospective randomized study. High thoracic epidural anesthesia allows early recovery, but improved outcome could not be proved in this patient group.
Early in vivo experience with the pediatric continuous-flow total artificial heart.
Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Kuban, Barry D; Gao, Shengqiang; Dessoffy, Raymond; Fukamachi, Kiyotaka
2018-03-30
Heart transplantation in infants and children is an accepted therapy for end-stage heart failure, but donor organ availability is low and always uncertain. Mechanical circulatory support is another standard option, but there is a lack of intracorporeal devices due to size and functional range. The purpose of this study was to evaluate the in vivo performance of our initial prototype of a pediatric continuous-flow total artificial heart (P-CFTAH), comprising a dual pump with one motor and one rotating assembly, supported by a hydrodynamic bearing. In acute studies, the P-CFTAH was implanted in 4 lambs (average weight: 28.7 ± 2.3 kg) via a median sternotomy under cardiopulmonary bypass. Pulmonary and systemic pump performance parameters were recorded. The experiments showed good anatomical fit and easy implantation, with an average aortic cross-clamp time of 98 ± 18 minutes. Baseline hemodynamics were stable in all 4 animals (pump speed: 3.4 ± 0.2 krpm; pump flow: 2.1 ± 0.9 liters/min; power: 3.0 ± 0.8 W; arterial pressure: 68 ± 10 mm Hg; left and right atrial pressures: 6 ± 1 mm Hg, for both). Any differences between left and right atrial pressures were maintained within the intended limit of ±5 mm Hg over a wide range of ratios of systemic-to-pulmonary vascular resistance (0.7 to 12), with and without pump-speed modulation. Pump-speed modulation was successfully performed to create arterial pulsation. This initial P-CFTAH prototype met the proposed requirements for self-regulation, performance, and pulse modulation. Copyright © 2018 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.
Parissis, Haralabos; Lau, Man Chi; Parissis, Mondrian; Lampridis, Savvas; Graham, Victoria; Al-Saudi, Reza; Mhandu, Peter
2015-12-17
The off-pump literature is divided into three eras: the "early phase" with results favouring off-pump surgery supported with randomized control trials (RCTs) mainly from Bristol, UK; an "intermediate phase" dominated by the results of the ROOBY trial and finally a more "contemporary phase" whereby the off/on-pump argument is unsettled. Although the literature has failed to project an overall superiority of off-pump versus on-pump surgery, nevertheless, small randomized control trials and large meta-analysis studies are concluding that the incidence of a stroke is less than 1 % when an aortic off-pump techniques (especially the non-touch technique) are advocated in patients with diseased ascending aorta. Furthermore, off-pump combined with hybrid procedures may lead to a reduction of adverse outcome in the aged high-risk population with concomitant poor left ventricular function and co-morbidities.The current review attempts to bring an insight onto the last ten years knowledge on the on/off-pump debate, with an aim to draw some clear conclusions in order to allow practitioners to reflect on the subject.
Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M
Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.
Circulatory support for OPCAB procedures.
Mueller, Xavier M; von Segesser, Ludwig K
2002-07-01
During off-pump coronary artery bypass grafting (OPCAB) which allows complete revascularization through a median sternotomy, revascularization of the lateral and posterior walls requires the verticalization of the heart, which may cause haemodynamic disturbance. This concern has stimulated the development of circulatory support with mini-pumps. Initially, these pumps were designed for the right side of the heart, which was found to be the main contributor to haemodynamic instability under experimental conditions. The three types of mini-pumps that have been developed so far - two for the right side of the heart and one for both sides - are reviewed as well as a new concept of integrated cardiopulmonary bypass (CPB) circuit with reduced surface and priming volume. However, with increasing experience and improved methods of exposition, OPCAB has become a procedure that can be performed without support in the majority of the cases. Nevertheless, the concept of miniaturization and the possibility to insert these devices through a peripheral access has opened the way to new indications, mainly short-term circulatory support for acute heart failure. This development is welcome in a field where available devices are invasive and plagued with a heavy morbidity.
Development of a jet pump-assisted arterial heat pipe
NASA Technical Reports Server (NTRS)
Bienert, W. B.; Ducao, A. S.; Trimmer, D. S.
1977-01-01
The development of a jet pump assisted arterial heat pipe is described. The concept utilizes a built-in capillary driven jet pump to remove vapor and gas from the artery and to prime it. The continuous pumping action also prevents depriming during operation of the heat pipe. The concept is applicable to fixed conductance and gas loaded variable conductance heat pipes. A theoretical model for the jet pump assisted arterial heat pipe is presented. The model was used to design a prototype for laboratory demonstration. The 1.2 m long heat pipe was designed to transport 500 watts and to prime at an adverse elevation of up to 1.3 cm. The test results were in good agreement with the theoretical predictions. The heat pipe carried as much as 540 watts and was able to prime up to 1.9 cm. Introduction of a considerable amount of noncondensible gas had no adverse effect on the priming capability.
Chopski, Steven G; Rangus, Owen M; Moskowitz, William B; Throckmorton, Amy L
2014-09-01
A mechanical blood pump specifically designed to increase pressure in the great veins would improve hemodynamic stability in adolescent and adult Fontan patients having dysfunctional cavopulmonary circulation. This study investigates the impact of axial-flow blood pumps on pressure, flow rate, and energy augmentation in the total cavopulmonary circulation (TCPC) using a patient-specific Fontan model. The experiments were conducted for three mechanical support configurations, which included an axial-flow impeller alone in the inferior vena cava (IVC) and an impeller with one of two different protective stent designs. All of the pump configurations led to an increase in pressure generation and flow in the Fontan circuit. The increase in IVC flow was found to augment pulmonary arterial flow, having only a small impact on the pressure and flow in the superior vena cava (SVC). Retrograde flow was neither observed nor measured from the TCPC junction into the SVC. All of the pump configurations enhanced the rate of power gain of the cavopulmonary circulation by adding energy and rotational force to the fluid flow. We measured an enhancement of forward flow into the TCPC junction, reduction in IVC pressure, and only minimally increased pulmonary arterial pressure under conditions of pump support. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Outcomes of cardiac surgery in the elderly.
Drury, Nigel E; Nashef, Samer A M
2006-07-01
The elderly represent a rapidly growing and substantially under-treated sector in industrialized countries, with coronary artery disease and degenerative aortic stenosis rampant. The proportion of elderly patients undergoing cardiac surgery is rising steadily and outcomes continue to improve with the refinement of operative techniques and perioperative care. Advanced risk stratification models, such as the logistic European System for Cardiac Operative Risk Evaluation now offer validated prediction of operative mortality in these high-risk patients. Current trends towards off-pump coronary artery surgery, hybrid revascularization and mitral repair may have advantages in the elderly, who often have more diffuse cardiovascular disease and a lower tolerance to intervention. Recent advances may also provide surgical options for the emerging epidemics of cardiovascular disease affecting the elderly, atrial fibrillation and heart failure.
A servo-controlled canine model of stable severe ischemic left ventricular failure.
Wagner, Richard L; Hood, William B; Howland, Peter A
2009-12-01
Reversible left ventricular failure was produced in conscious dogs by compromise of the coronary circulation. In animals with prior left anterior descending coronary artery occlusion, mean left atrial pressure (LAP) was incorporated into an automatic feedback control system used to inflate a balloon cuff on the circumflex (Cfx) coronary artery. The system could produce stable increases in LAP to 15-20 mm Hg. The dominating system transfer function was the ratio of LAP to balloon volume (BV), which was characterized by a fixed delay (5 s), with LAP/BV = (8e(-jomegatau ))/(0.02 + jomega). The system was stabilized by a phase lead network to reduce oscillations of LAP. A total of seven experiments were conducted in three dogs, and testing of inotropic agents was possible in three experiments under stable conditions with the pump off after an hour or more of operation. Problems encountered were 0.003-0.008 Hz oscillations in LAP in three experiments, which could usually be controlled by reducing the system gain. Late stage ventricular fibrillation occurred in all three animals, but defibrillation was easily accomplished after deflating the Cfx balloon. This system produces reversible left ventricular failure solely due to ischemia, thus closely simulating clinical heart failure due to coronary insufficiency.
Spencer, Shannon B; Wang, Shigang; Woitas, Karl; Glass, Kristen; Kunselman, Allen R; Ündar, Akif
2017-01-01
The objective of this study was to evaluate an alternative neonatal extracorporeal life support (ECLS) circuit with a RotaFlow centrifugal pump and Better-Bladder (BB) for hemodynamic performance and gaseous microemboli (GME) capture in a simulated neonatal ECLS system. The circuit consisted of a Maquet RotaFlow centrifugal pump, a Quadrox-iD Pediatric diffusion membrane oxygenator, 8 Fr arterial cannula, and 10 Fr venous cannula. A "Y" connector was inserted into the venous line to allow for comparison between BB and no BB. The circuit and pseudopatient were primed with lactated Ringer's solution and packed human red blood cells (hematocrit 35%). All hemodynamic trials were conducted at flow rates ranging from 100 to 600 mL/min at 36°C. Real-time pressure and flow data were recorded using a data acquisition system. For GME testing, 0.5 cc of air was injected via syringe into the venous line. GME were detected and characterized with or without the BB using the Emboli Detection and Classification Quantifier (EDAC) System. Trials were conducted at flow rates ranging from 200 to 500 mL/min. The hemodynamic energy data showed that up to 75.2% of the total hemodynamic energy was lost from the circuit. The greatest pressure drops occurred across the arterial cannula and increased with increasing flow rate from 10.1 mm Hg at 100 mL/min to 114.3 mm Hg at 600 mL/min. The EDAC results showed that the BB trapped a significant amount of the GME in the circuit. When the bladder was removed, GME passed through the pump head and the oxygenator to the arterial line. This study showed that a RotaFlow centrifugal pump combined with a BB can help to significantly decrease the number of GME in a neonatal ECLS circuit. Even with this optimized alternative circuit, a large percentage of the total hemodynamic energy was lost. The arterial cannula was the main source of resistance in the circuit. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Reoma, Junewai L; Rojas, Alvaro; Krause, Eric M; Obeid, Nabeel R; Lafayette, Nathan G; Pohlmann, Joshua R; Padiyar, Niru P; Punch, Jeffery D; Cook, Keith E; Bartlett, Robert H
2009-01-01
Extracorporeal cardiopulmonary support (ECS) of donors after cardiac death (DCD) has been shown to improve abdominal organs for transplantation. This study assesses whether pulmonary congestion occurs during ECS with the heart arrested and describes an in vivo method to assess if lungs are suitable for transplantation from DCD donors after ECS resuscitation. Cardiac arrest was induced in 30 kg pigs, followed by 10 min of warm ischemia. Cannulae were placed into the right atrium (RA) and iliac artery, and veno-arterial ECS was initiated for 90 min with lungs inflated, group 1 (n = 5) or deflated, group 2 (n = 3). Left atrial pressures were measured as a marker for pulmonary congestion. After 90 min of ECS, lung function was evaluated. Cannulae were placed into the pulmonary artery (PA) and left ventricle (LV). A second pump was included, and ECS was converted to a bi-ventricular (bi-VAD) system. The RVAD drained from the RA and pumped into the PA, and the LVAD drained the LV and pumped into the iliac. This brought the lungs back into circulation for a 1-hr assessment period. The oxygenator was turned off, and ventilation was restarted. Flows, blood gases, PA and left atrial pressures, and compliance were recorded. In both the groups, LA pressure was <15 mm Hg during ECS. During the lung assessment period, PA flows were 1.4-2.2 L/min. PO2 was >300 mm Hg, with normal PCO2. Extracorporeal cardiopulmonary support resuscitation of DCD donors is feasible and allows for assessment of function before procurement. Extracorporeal cardiopulmonary support does not cause pulmonary congestion, and the lungs retain adequate function for transplantation. Compliance correlated with lung function.
Hofland, Jan; Ouattara, Alexandre; Fellahi, Jean-Luc; Gruenewald, Matthias; Hazebroucq, Jean; Ecoffey, Claude; Joseph, Pierre; Heringlake, Matthias; Steib, Annick; Coburn, Mark; Amour, Julien; Rozec, Bertrand; Liefde, Inge de; Meybohm, Patrick; Preckel, Benedikt; Hanouz, Jean-Luc; Tritapepe, Luigi; Tonner, Peter; Benhaoua, Hamina; Roesner, Jan Patrick; Bein, Berthold; Hanouz, Luc; Tenbrinck, Rob; Bogers, Ad J J C; Mik, Bert G; Coiffic, Alain; Renner, Jochen; Steinfath, Markus; Francksen, Helga; Broch, Ole; Haneya, Assad; Schaller, Manuella; Guinet, Patrick; Daviet, Lauren; Brianchon, Corinne; Rosier, Sebastien; Lehot, Jean-Jacques; Paarmann, Hauke; Schön, Julika; Hanke, Thorsten; Ettel, Joachym; Olsson, Silke; Klotz, Stefan; Samet, Amir; Laurinenas, Giedrius; Thibaud, Adrien; Cristinar, Mircea; Collanges, Olivier; Levy, François; Rossaint, Rolf; Stevanovic, Ana; Schaelte, Gereon; Stoppe, Christian; Hamou, Nora Ait; Hariri, Sarah; Quessard, Astrid; Carillion, Aude; Morin, Hélène; Silleran, Jacqueline; Robert, David; Crouzet, Anne-Sophie; Zacharowski, Kai; Reyher, Christian; Iken, Sonja; Weber, Nina C; Hollmann, Marcus; Eberl, Susanne; Carriero, Giovanni; Collacchi, Daria; Di Persio, Alessandra; Fourcade, Olivier; Bergt, Stefan; Alms, Angela
2017-12-01
Ischemic myocardial damage accompanying coronary artery bypass graft surgery remains a clinical challenge. We investigated whether xenon anesthesia could limit myocardial damage in coronary artery bypass graft surgery patients, as has been reported for animal ischemia models. In 17 university hospitals in France, Germany, Italy, and The Netherlands, low-risk elective, on-pump coronary artery bypass graft surgery patients were randomized to receive xenon, sevoflurane, or propofol-based total intravenous anesthesia for anesthesia maintenance. The primary outcome was the cardiac troponin I concentration in the blood 24 h postsurgery. The noninferiority margin for the mean difference in cardiac troponin I release between the xenon and sevoflurane groups was less than 0.15 ng/ml. Secondary outcomes were the safety and feasibility of xenon anesthesia. The first patient included at each center received xenon anesthesia for practical reasons. For all other patients, anesthesia maintenance was randomized (intention-to-treat: n = 492; per-protocol/without major protocol deviation: n = 446). Median 24-h postoperative cardiac troponin I concentrations (ng/ml [interquartile range]) were 1.14 [0.76 to 2.10] with xenon, 1.30 [0.78 to 2.67] with sevoflurane, and 1.48 [0.94 to 2.78] with total intravenous anesthesia [per-protocol]). The mean difference in cardiac troponin I release between xenon and sevoflurane was -0.09 ng/ml (95% CI, -0.30 to 0.11; per-protocol: P = 0.02). Postoperative cardiac troponin I release was significantly less with xenon than with total intravenous anesthesia (intention-to-treat: P = 0.05; per-protocol: P = 0.02). Perioperative variables and postoperative outcomes were comparable across all groups, with no safety concerns. In postoperative cardiac troponin I release, xenon was noninferior to sevoflurane in low-risk, on-pump coronary artery bypass graft surgery patients. Only with xenon was cardiac troponin I release less than with total intravenous anesthesia. Xenon anesthesia appeared safe and feasible.
Kapoor, Poonam Malhotra; Magoon, Rohan; Rawat, Rajinder Singh; Mehta, Yatin; Taneja, Sameer; Ravi, R; Hote, Milind P
2017-01-01
There has been a constant emphasis on developing management strategies to improve the outcome of high-risk cardiac patients undergoing surgical revascularization. The performance of coronary artery bypass surgery on an off-pump coronary artery bypass (OPCAB) avoids the risks associated with extra-corporeal circulation. The preliminary results of goal-directed therapy (GDT) for hemodynamic management of high-risk cardiac surgical patients are encouraging. The present study was conducted to study the outcome benefits with the combined use of GDT with OPCAB as compared to the conventional hemodynamic management. Patients with the European System for Cardiac Operative Risk Evaluation ≥3 scheduled for OPCAB were randomly divided into two groups; the control and GDT groups. The GDT group included the monitoring and optimization of advanced parameters, including cardiac index (CI), systemic vascular resistance index, oxygen delivery index, stroke volume variation; continuous central venous oxygen saturation (ScVO 2 ), global end-diastolic volume, and extravascular lung water (EVLW), using FloTrac™ , PreSep™ , and EV-1000 ® monitoring panels, in addition to the conventional hemodynamic management in the control group. The hemodynamic parameters were continuously monitored for 48 h in Intensive Care Unit (ICU) and corrected according to GDT protocol. A total of 163 patients consented for the study. Seventy-five patients were assigned to the GDT group and 88 patients were in the control group. In view of 9 exclusions from the GDT group and 12 exclusions from control group, 66 patients in the GDT group and 76 patients in control group completed the study. The length of stay in hospital (LOS-H) (7.42 ± 1.48 vs. 5.61 ± 1.11 days, P < 0.001) and ICU stay (4.2 ± 0.82 vs. 2.53 ± 0.56 days, P < 0.001) were significantly lower in the GDT group as compared to control group. The duration of inotropes (3.24 ± 0.73 vs. 2.89 ± 0.68 h, P = 0.005) was also significantly lower in the GDT group. The two groups did not differ in duration of ventilated hours, mortality, and other complications. The parameters such as ScVO 2 , CI, and EVLW had a strong negative and positive correlation with the LOS-H with r values of - 0.331, -0.319, and 0.798, respectively. The study elucidates the role of a goal-directed hemodynamic optimization for improved outcome in high-risk cardiac patients undergoing OPCAB.
Wang, Bin; Jia, Ming; Jia, Shijie; Wan, Jiuhe; Zhou, Xiao; Luo, Zhimin; Zhou, Ye; Zhang, Jianqun
2014-06-01
To analyse risk factors for early acute cerebrovascular accidents following off-pump coronary artery bypass grafting (OPCAB) in patients with stroke history, and to propose preventive measures to reduce the incidence of these events. A total of 468 patients with a history of stroke underwent OPCAB surgery in Beijing Anzhen Hospital of China from January 2010 to September 2012. They were retrospectively divided into two groups according to the occurrence of early acute cerebrovascular accidents within 48 hours following OPCAB. Multivariate logistic regression analysis was used to find risk or protective factors for early acute cerebrovascular accidents following the OPCAB. Fifty-two patients (11.1%) suffered from early acute cerebrovascular accidents in 468 patients, including 39 cases of cerebral infarction, two cases of cerebral haemorrhage, 11 cases of transient ischaemic attack (TIA). There were significant differences between the two groups in preoperative left ventricular ejection fraction ≤ 35%, severe bilateral carotid artery stenosis, poorly controlled hypertension, intraoperative application of Enclose® II proximal anastomotic device, postoperative acute myocardial infarction, atrial fibrillation, hypotension, ventilation time > 48h, ICU duration >48h and mortality. Multivariate logistic regression analysis showed that preoperative severe bilateral carotid stenosis (OR=6.378, 95%CI: 2.278-20.987) and preoperative left ventricular ejection fraction ≤ 35% (OR=2.737, 95%CI: 1.267-6.389), postoperative acute myocardial infarction (OR=3.644, 95%CI: 1.928-6.876), postoperative atrial fibrillation (OR=3.104, 95%CI:1.135∼8.016) and postoperative hypotension (OR=4.173, 95%CI: 1.836∼9.701) were independent risk factors for early acute cerebrovascular accidents in patients with a history of stroke following OPCAB procedures, while intraoperative application of Enclose® II proximal anastomotic device was protective factor (OR=0.556, 95%CI: 0.337-0.925). This study indicated that patients with severe bilateral carotid stenosis, the left ventricular ejection fraction ≤35%, the postoperative acute myocardial infarction, postoperative atrial fibrillation and postoperative hypotension were more likely to suffer from early acute cerebrovascular accidents when they received OPCAB. Application of Enclose® II proximal anastomotic device may decrease the incidence of early acute cerebrovascular accidents during OPCAB. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Joshi, Subodh B; Roswell, Robert O; Salah, Ali K; Zeman, Peter R; Corso, Paul J; Lindsay, Joseph; Fuisz, Anthon R
2010-01-01
A reduction in right ventricular function commonly occurs in the early postoperative period after coronary artery bypass graft surgery (CABG). We sought to determine the longer-term effect of CABG on right ventricular function. Cardiac magnetic resonance imaging was performed before and approximately 3 months after surgery in 28 patients undergoing elective CABG. Right ventricular (RV) ejection fraction was assessed by planimetry of electrocardiographically gated cine images. There was a statistically significant increase in left ventricular ejection fraction from 50% to 58% (P=.003) after CABG. RV ejection fraction also increased from 54% to 60% (P=.002). In patients with lower baseline RV ejection fraction (below the median, < 53%), this parameter improved from 47% to 57% (P<.001). Both on-pump (47% vs. 62%, P=.003) as well as off-pump CABG (47% vs. 55%, P=.009) lead to an improvement in RV function in patients in the initial low RV ejection fraction group. Long-term right ventricular function was not adversely affected by CABG. An improvement in RV function occurred after surgery in patients with low baseline RV ejection fraction and was similar in patients who underwent surgery with or without cardiopulmonary bypass.
The feasibility and safety of off-pump coronary bypass surgery in emergency revascularization
Joo, Hyun-Chel; Youn, Young-Nam; Chang, Byung-Chul
2018-01-01
Background The efficacy and safety of off-pump coronary artery bypass grafting (OPCAB) in emergency revascularization remains controversial despite its widespread use. The aim of our study was to examine the applicability and safety of OPCAB in patients who were indicated for emergency surgery. Methods This single-center study reviewed the indication, operative data, and early and long-term outcomes of 113 patients (mean age, 67.2±9.0 years; logistic EuroSCORE, 14.3±13.5) who underwent emergency OPCAB from January 2003 to December 2014 and were followed up (94.6% completion rate) for a mean 51.1±40.3 (range, 1–135) months. Results Emergency OPCAB was associated with favorable surgical outcomes (number of distal anastomoses per patient, 3.04±0.87; internal thoracic artery (IMA) use, 98.2%; complete revascularization, 79.6%) and in-hospital outcomes (mortality, 5.3%; low cardiac output syndrome, 5.3%; stroke, 2.7%; pulmonary complications, 8.8%; renal failure, 11.5%). Only five patients (4.4%) required on-pump conversion. The 10-year outcomes were also acceptable (survival, 75.4%±5.6%; major cerebral and cardiovascular events, 52.1%±1.8%). The multivariate risk factors for late mortality were peripheral vascular disease (HR 2.95, 95% CI: 1.11–11.83), cardiogenic shock (HR 3.67, 95% CI: 1.35–9.96), and incomplete revascularization (HR 3.41, 95% CI: 1.06–14.26). When patients were separated by whether the procedure was performed early (<2010) or late (≥2010) in the study period, the late period cohort had better outcomes despite containing higher-risk patients. Conclusions Our study suggests that emergency OPCAB can be performed safely and effectively with good hospital outcomes and adequate long-term results. OPCAB strategy can be considered as a good option in emergency revascularization. PMID:29850131
Marui, Akira; Kimura, Takeshi; Tanaka, Shiro; Furukawa, Yutaka; Kita, Toru; Sakata, Ryuzo
2012-01-01
Although there have been several studies that compared the efficacy of percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG), the impact of off-pump CABG (OPCAB) has not been well elucidated. The objective of the present study was to compare the outcomes after PCI, on-pump CABG (ONCAB), and OPCAB in patients with multivessel and/or left main disease. Among the 9877 patients undergoing first PCI using bare-metal stents or CABG who were enrolled in the CREDO-Kyoto Registry, 6327 patients with multivessel and/or left main disease were enrolled into the present study (67.9±9.8 years old). Among them, 3877 patients received PCI, 1388 ONCAB, and 1069 OPCAB. Median follow-up was 3.5 years. Comparing PCI with all CABG (ONCAB and OPCAB), propensity-score-adjusted all-cause mortality after PCI was higher than that CABG (hazard ratio (95% confidence interval): 1.37 (1.15-1.63), p<0.01). The incidence of stroke was lower after PCI than that after CABG (0.75 (0.59-0.96), p=0.02). CABG was associated with better survival outcomes than PCI in the elderly (interaction p=0.04). Comparing OPCAB with PCI or ONCAB, propensity-score-adjusted all-cause mortality after PCI was higher than that after OPCAB (1.50 (1.20-1.86), p<0.01). Adjusted mortality was similar between ONCAB and OPCAB (1.18 (0.93-1.51), p=0.33). The incidence of stroke after OPCAB was similar to that after PCI (0.98 (0.71-1.34), p>0.99), but incidence of stroke after ONCAB was higher than that after OPCAB (1.59 (1.16-2.18), p<0.01). In patients with multivessel and/or left main disease, CABG, particularly OPCAB, is associated with better survival outcomes than PCI using bare-metal stents. Survival outcomes are similar between ONCAB and OPCAB.
Pizon, M T; Gburek, T; Pizon, M; Sztefko, K
2006-12-01
Heat shock protein HSP-70 is known as protective chaperone molecule synthetized in response following ischemia and stress agents. It is detected in the myocardium and endothelium as well as in the circulation. Damaged as well as viable but exposed to stress cells contribute to the release of HSP-70 into the circulation. The aim of the study was to investigate if cardiopulmonary bypss (CPB) leads to more circulating HSP-70, on the basis of comparison dynamics of plasma concentration HSP-70 in 8 men undergoing procedures with the use of CPB (coronary artery bypass grafting, CABG group) and 8 men undergoing off-pump surgery (OPCAB group). Blood samples were taken preoperatively, twice intraoperatively, immediately after surgical procedure (1 h) and 24-hours thereafter. The concentration of plasma HSP-70 was measured by means of immunoassay. The derived results were compared statistically with the frequency of incidence postoperative atrial fibrillation (AF). In CABG group was observed continuous gradual increase of plasma HSP-70 concentration during the operation with the peak 1 h after surgery (P<0.01), in striking contrast to OPCAB group, in which was detected small, but non statistically significant increase of HSP-70 1 h after operation. Significantly more of circulating HSP-70 it was detected in CABG group during the operation and 1 h after surgery (CABG vs OPCAB, respectively P<0.015 and P<0.028). In both groups among patients witch AF it was found higher postoperative values of circulating HSP-70 compared with the non-AF group (P=0.0415). The use of CPB leads to significant more release of HSP-70 into the circulation. According to our findings high plasma concentration of HSP-70 may be the measure of operative cellular stress, ischemia or injury and may be related with greater onset of postoperative AF. High circulating HSP-70 levels is connected with higher incidence of postoperative AF after open heart surgery.
Hourly simulation of a Ground-Coupled Heat Pump system
NASA Astrophysics Data System (ADS)
Naldi, C.; Zanchini, E.
2017-01-01
In this paper, we present a MATLAB code for the hourly simulation of a whole Ground-Coupled Heat Pump (GCHP) system, based on the g-functions previously obtained by Zanchini and Lazzari. The code applies both to on-off heat pumps and to inverter-driven ones. It is employed to analyse the effects of the inverter and of the total length of the Borehole Heat Exchanger (BHE) field on the mean seasonal COP (SCOP) and on the mean seasonal EER (SEER) of a GCHP system designed for a residential house with 6 apartments in Bologna, North-Center Italy, with dominant heating loads. A BHE field with 3 in line boreholes is considered, with length of each BHE either 75 m or 105 m. The results show that the increase of the BHE length yields a SCOP enhancement of about 7%, while the SEER remains nearly unchanged. The replacement of the on-off heat pump by an inverter-driven one yields a SCOP enhancement of about 30% and a SEER enhancement of about 50%. The results demonstrate the importance of employing inverter-driven heat pumps for GCHP systems.
Prates, Paulo Roberto L.; Williams, Judson B.; Mehta, Rajendra H.; Stevens, Susanna R.; Thomas, Laine; Smith, Peter K.; Newby, L. Kristin; Kalil, Renato A. K.; Alexander, John H.; Lopes, Renato D.
2016-01-01
Introduction Antiplatelet therapy after coronary artery bypass graft (CABG) has been used. Little is known about the predictors and efficacy of clopidogrel in this scenario. Objective Identify predictors of clopidogrel following CABG. Methods We evaluated 5404 patients who underwent CABG between 2000 and 2009 at Duke University Medical Center. We excluded patients undergoing concomitant valve surgery, those who had postoperative bleeding or death before discharge. Postoperative clopidogrel was left to the discretion of the attending physician. Adjusted risk for 1-year mortality was compared between patients receiving and not receiving clopidogrel during hospitalization after undergoing CABG. Results At hospital discharge, 931 (17.2%) patients were receiving clopidogrel. Comparing patients not receiving clopidogrel at discharge, users had more comorbidities, including hyperlipidemia, hypertension, heart failure, peripheral arterial disease and cerebrovascular disease. Patients who received aspirin during hospitalization were less likely to receive clopidogrel at discharge (P≤0.0001). Clopidogrel was associated with similar 1-year mortality compared with those who did not use clopidogrel (4.4% vs. 4.5%, P=0.72). There was, however, an interaction between the use of cardiopulmonary bypass and clopidogrel, with lower 1-year mortality in patients undergoing off-pump CABG who received clopidogrel, but not those undergoing conventional CABG (2.6% vs 5.6%, P Interaction = 0.032). Conclusion Clopidogrel was used in nearly one-fifth of patients after CABG. Its use was not associated with lower mortality after 1 year in general, but lower mortality rate in those undergoing off-pump CABG. Randomized clinical trials are needed to determine the benefit of routine use of clopidogrel in CABG. PMID:27556308
Yulong Guan; Xiaowei Su; McCoach, Robert; Kunselman, Allen; El-Banayosy, Aly; Undar, Akif
2010-03-01
Centrifugal blood pumps have been widely adopted in conventional adult cardiopulmonary bypass and circulatory assist procedures. Different brands of centrifugal blood pumps incorporate distinct designs which affect pump performance. In this adult extracorporeal life support (ECLS) model, the performances of two brands of centrifugal blood pump (RotaFlow blood pump and CentriMag blood pump) were compared. The simulated adult ECLS circuit used in this study included a centrifugal blood pump, Quadrox D membrane oxygenator and Sorin adult ECLS tubing package. A Sorin Cardiovascular(R) VVR(R) 4000i venous reservoir (Sorin S.p.A., Milan, Italy) with a Hoffman clamp served as a pseudo-patient. The circuit was primed with 900ml heparinized human packed red blood cells and 300ml lactated Ringer's solution (total volume 1200 ml, corrected hematocrit 40%). Trials were conducted at normothermia (36 degrees C). Performance, including circuit pressure and flow rate, was measured for every setting analyzed. The shut-off pressure of the RotaFlow was higher than the CentriMag at all measurement points given the same rotation speed (p < 0.0001). The shut-off pressure differential between the two centrifugal blood pumps was significant and increased given higher rotation speeds (p < 0.0001). The RotaFlow blood pump has higher maximal flow rate (9.08 +/- 0.01L/min) compared with the CentriMag blood pump (8.37 +/- 0.02L/min) (p < 0.0001). The blood flow rate differential between the two pumps when measured at the same revolutions per minute (RPM) ranged from 1.64L/min to 1.73L/min. The results obtained in this experiment demonstrate that the RotaFlow has a higher shut-off pressure (less retrograde flow) and maximal blood flow rate than the CentriMag blood pump. Findings support the conclusion that the RotaFlow disposable pump head has a better mechanical performance than the CentriMag. In addition, the RotaFlow disposable pump is 20-30 times less expensive than the CentriMag.
Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance
NASA Technical Reports Server (NTRS)
Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.
2002-01-01
This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.
Automated Weaning from Mechanical Ventilation after Off-Pump Coronary Artery Bypass Grafting.
Fot, Evgenia V; Izotova, Natalia N; Yudina, Angelika S; Smetkin, Aleksei A; Kuzkov, Vsevolod V; Kirov, Mikhail Y
2017-01-01
The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning ( n = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning ( n = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO 2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group ( p < 0.01). The average time until tracheal extubation did not differ in the automated weaning and the protocolized weaning groups: 193 (115-309) and 197 (158-253) min, respectively, but increased to 290 (210-411) min in the standard weaning group. The automated weaning system after off-pump coronary surgery might provide postoperative ventilation in a more protective way, reduces the workload on medical staff, and does not prolong the duration of weaning from ventilator. The use of automated or protocolized weaning can reduce the duration of postoperative mechanical ventilation in comparison with non-protocolized weaning based on the physician's decision.
Current indications for left thoracotomy in coronary revascularization and valvular procedures.
Pratt, J W; Williams, T E; Michler, R E; Brown, D A
2000-10-01
Left thoracotomy is infrequently used for cardiac procedures, but its application in reoperative and minimally invasive coronary revascularization and in valvular procedures has been reported recently. Three case reports and a review of the current literature illustrate the unique benefits of this approach for myocardial revascularization and valve replacement. Reoperative coronary revascularization of the left anterior descending and circumflex coronary arteries was performed off-pump via a left posterolateral thoracotomy. For the second case, this approach was used for coronary artery bypass grafting of the right coronary and left anterior descending arteries with femoral-femoral cardiopulmonary bypass in a patient with congestive heart failure and coronary artery disease who also required closure of a patent ductus arteriosus. In the third case, mitral valve replacement using femoral venous and aortic cannulation for cardiopulmonary bypass was performed via a left thoracotomy to avoid a retrosternal gastric conduit in a patient with severe mitral stenosis and congestive heart failure. All patients returned to normal activity and are asymptomatic. These case reports and a comprehensive review of the literature demonstrate the utility of left thoracotomy as an alternative approach to standard median sternotomy in selected cases of revascularization and valvular procedures.
Succi, José Ernesto; Gerola, Luis Roberto; Succi, Guilherme de Menezes; Kim, Hyong Chun; Paredes, Jorge Edwin Morocho; Bufollo, Enio
2012-01-01
To evaluate intraoperative graft patency and identify grafts under risk of early occlusion. Fifty four patients were submitted to coronary artery bypass surgery and the graft flow was assessed by the Flowmeter (Medtronic Medistim), which utilizes the TTFM method. Three patients had left main disease and 48 had normal or mildly reduced left ventricular function. In hospital mortality was 3.7% (two patients), one for mesenteric thrombosis and one due to cardiogenic chock. Seventeen patients (34%) were submitted to off pump CABG. Arterial Graft flow measures ranged from 8 to 106 ml/min (average 31.14 ml/min), and venous grafts flow ranged from 9 to 149 ml/min (average 50.42 ml/min). Flowmeter use represents higher safety both for patients and surgeons. Even under legal aspects, the documentation provided by the device can avoid future questionings.
Borde, Deepak Prakash; Futane, Savani Sameer; Asegaonkar, Balaji; Apsingekar, Pramod; Khade, Sujeet; Khodve, Bapu; Puranik, Manish; George, Antony; Joshi, Shreedhar
2017-08-01
Use of pregabalin is increasing in cardiac surgical patients. However, studies using comprehensive scoring systems are lacking on the drug's impact on postoperative recovery. The authors tested the hypothesis that perioperative oral pregabalin improves the postoperative quality of recovery as assessed using the Quality of Recovery (QoR-40) questionnaire in patients undergoing off-pump coronary artery bypass grafting (OPCABG). This was a randomized, double-blind, placebo-controlled study. Tertiary-care hospital. Patients undergoing OPCABG. Patients were assigned randomly to the following 2 groups: the pregabalin group (those who received pregabalin, 150 mg capsule orally, 1 hour before surgery and 2 days postoperatively [75 mg twice a day] starting after extubation; n = 37); and the control group (those who received 2 similar-looking multivitamin capsules at similar times; n = 34). The QoR-40 scores were noted preoperatively and 24 hours after extubation. Both groups were comparable in terms of preoperative patient characteristics and baseline QoR-40 scores. Global scores were significantly improved in the pregabalin group compared with the control group in the postoperative period (177±9 v 170±9; p = 0.002). QoR-40 values in the dimensions of emotional state (p = 0.005), physical comfort (p = 0.04), and pain (p = 0.02) were improved in the pregabalin group. Perioperative pregabalin improved postoperative quality of recovery as assessed using the QoR-40 questionnaire in patients undergoing OPCABG. Perioperative pregabalin offered advantages beyond better pain control, such as improved physical comfort and better emotional state; therefore, the drug's use in the perioperative period is recommended. Copyright © 2017 Elsevier Inc. All rights reserved.
Matsuura, Kaoru; Mogi, Kenji; Sakurai, Manabu; Kawamura, Tomonori; Takahara, Yoshiharu
2013-09-01
This study aimed to assess the impact of aortic manipulation during off-pump coronary artery bypass (OPCAB) on neurological complications. Of 336 isolated OPCAB surgeries, the aorta was untouched in 264 cases (group A), whereas it was manipulated by a side-biting clamp in 72 (group B). The average follow-up was 2.9±2.5 years. One patient in each group developed postoperative stroke (P=0.38). The prevalence of triple-vessel disease (group A 40.9% vs. group B 61.1%; P=0.0003) and left main trunk disease (group A 30.7% vs. group B 47.2%; P=0.1) was lower in group A than in group B. The number of bypass grafts (group A 2.18±0.97 vs. group B 3.00±0.97; P=0.0001) was lower in group A than in group B. The prevalence of preoperative atrial fibrillation and the incidence of new-onset postoperative atrial fibrillation were not different between groups (P=0.74 and 0.86, respectively). Survival rate and freedom from major adverse cardiac events were not different between groups (P=0.87 and 0.51, respectively). However, freedom from neurological complications was significantly lower in group A (P=0.0006). The Cox hazard model showed that aortic manipulation (P=0.004; odds ratio, 6.18; 95% confidence interval, 1.8-21.6) and preoperative atrial fibrillation (P=0.001; odds ratio, 14.0; 95% confidence interval, 2.7-72.5) were risk factors for neurological complications. Although there was no difference in the incidence of immediate postoperative neurological complications, there were fewer medium-term neurological complications in OPCAB cases without aortic manipulation.
Initial in vitro testing of a paediatric continuous-flow total artificial heart.
Fukamachi, Kiyotaka; Karimov, Jamshid H; Horvath, David J; Sunagawa, Gengo; Byram, Nicole A; Kuban, Barry D; Moazami, Nader
2018-06-01
Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.
Narendra Kumar, Karthik; Singh, Naveen G; P S, Nagaraja; Patil, Thimmangouda A; N, Manjunath
2017-10-01
The objective of the study was to investigate if the main pulmonary artery (mPA)-to-ascending aorta (AscAo), (mPA:AscAo) ratio could serve as a screening tool in identifying pulmonary artery hypertension (PAH). A prospective observational study. Tertiary care center, university hospital. Fifty-four adult patients undergoing off-pump coronary artery bypass grafting surgery (OPCAB). mPA and AscAo transverse diameters were measured by transesophageal echocardiography (TEE) and the mean pulmonary arterial pressures (mPAP) were recorded simultaneously using a pulmonary artery catheter. mPA:AscAo ratio demonstrated significant linear correlation with mPAP measured by pulmonary artery catheterization (ie, r = 0.61, confidence interval [CI] = 0.5352-0.6736, p < 0.0001). Receiver operating characteristic curves were performed to evaluate sensitivity and specificity of mPA:AscAo ratio ≥1 for diagnosing PAH (mPAP ≥25 mmHg). Area under the curve for mPA:AscAo ratio was 0.91 (95% CI, 0.869-0.936, p < 0.0001), with a sensitivity of 84.27%, specificity of 83.92%, positive-predictive value of 87.6% and negative-predictive value of 81.1% for a mPAP ≥25 mmHg. The ratio of mPA:AscAo is a simple, reliable, and reproducible method that can be obtained through TEE, which guides the clinician to screen patients with PAH. Copyright © 2017 Elsevier Inc. All rights reserved.
Masoumi, Gholamreza; Pour, Evaz Hidar; Sadeghpour, Ali; Ziayeefard, Mohsen; Alavi, Mostapha; Anbardan, Sanam Javid; Shirani, Shahin
2012-02-01
On-pump coronary artery bypass graft (CABG) surgery impairs gas exchange in the early postoperative period. The main object on this study was evaluation of changes in arterial blood gas values in patients underwent on pump CABG surgery receiving different dose of intravenous nitroglycerin (NTG). sixty-seven consecutive patients undergoing elective on-pump CABG randomly enrolled into three groups receiving NTG 50 μg/min (Group N1, n =67), 100 μg/min (Group N2, n = 67), and 150 μg/min (Group N3, n = 67). Arterial blood gas (ABG) tensions were evaluated just before induction of anesthesia, during anesthesia, at the end of warming up period, and 6 h after admission to the intensive care unit. Pao2 and PH had the highest value during surgery in Group N1, Group N2, and Group N3. No significant difference was noted in mean values of Pao2 and PH during surgery between three groups (P > 0.05). There was no significant difference in HCO3 values in different time intervals among three groups (P > 0.05). our results showed that infusing three different dosage of NTG (50, 100, and 150 μg/min) had no significant effect on ABG tensions in patients underwent on-pump CABG surgery.
Marui, Akira; Kimura, Takeshi; Tanaka, Shiro; Furukawa, Yutaka; Kita, Toru; Sakata, Ryuzo
2012-01-01
OBJECTIVE Although there have been several studies that compared the efficacy of percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG), the impact of off-pump CABG (OPCAB) has not been well elucidated. The objective of the present study was to compare the outcomes after PCI, on-pump CABG (ONCAB), and OPCAB in patients with multivessel and/or left main disease. METHODS Among the 9877 patients undergoing first PCI using bare-metal stents or CABG who were enrolled in the CREDO-Kyoto Registry, 6327 patients with multivessel and/or left main disease were enrolled into the present study (67.9 ± 9.8 years old). Among them, 3877 patients received PCI, 1388 ONCAB, and 1069 OPCAB. Median follow-up was 3.5 years. RESULTS Comparing PCI with all CABG (ONCAB and OPCAB), propensity-score-adjusted all-cause mortality after PCI was higher than that CABG (hazard ratio (95% confidence interval): 1.37 (1.15–1.63), p < 0.01). The incidence of stroke was lower after PCI than that after CABG (0.75 (0.59–0.96), p = 0.02). CABG was associated with better survival outcomes than PCI in the elderly (interaction p = 0.04). Comparing OPCAB with PCI or ONCAB, propensity-score-adjusted all-cause mortality after PCI was higher than that after OPCAB (1.50 (1.20–1.86), p < 0.01). Adjusted mortality was similar between ONCAB and OPCAB (1.18 (0.93–1.51), p = 0.33). The incidence of stroke after OPCAB was similar to that after PCI (0.98 (0.71–1.34), p > 0.99), but incidence of stroke after ONCAB was higher than that after OPCAB (1.59 (1.16–2.18), p < 0.01). CONCLUSIONS In patients with multivessel and/or left main disease, CABG, particularly OPCAB, is associated with better survival outcomes than PCI using bare-metal stents. Survival outcomes are similar between ONCAB and OPCAB. PMID:21676626
Liu, Guang-Mao; Jin, Dong-Hai; Jiang, Xi-Hang; Zhou, Jian-Ye; Zhang, Yan; Chen, Hai-Bo; Hu, Sheng-Shou; Gui, Xing-Min
The ventricular assist pumps do not always function at the design point; instead, these pumps may operate at unfavorable off-design points. For example, the axial ventricular assist pump FW-2, in which the design point is 5 L/min flow rate against 100 mm Hg pressure increase at 8,000 rpm, sometimes works at off-design flow rates of 1 to 4 L/min. The hemolytic performance of the FW-2 at both the design point and at off-design points was estimated numerically and tested in vitro. Flow characteristics in the pump were numerically simulated and analyzed with special attention paid to the scalar sheer stress and exposure time. An in vitro hemolysis test was conducted to verify the numerical results. The simulation results showed that the scalar shear stress in the rotor region at the 1 L/min off-design point was 70% greater than at the 5 L/min design point. The hemolysis index at the 1 L/min off-design point was 3.6 times greater than at the 5 L/min design point. The in vitro results showed that the normalized index of hemolysis increased from 0.017 g/100 L at the 5 L/min design point to 0.162 g/100 L at the 1 L/min off-design point. The hemolysis comparison between the different blood pump flow rates will be helpful for future pump design point selection and will guide the usage of ventricular assist pumps. The hemolytic performance of the blood pump at the working point in the clinic should receive more focus.
Al Tmimi, L; Van Hemelrijck, J; Van de Velde, M; Sergeant, P; Meyns, B; Missant, C; Jochmans, I; Poesen, K; Coburn, M; Rex, S
2015-10-01
Off-pump coronary artery bypass (OPCAB) surgery carries a high risk for haemodynamic instability and perioperative organ injury. Favourable haemodynamic effects and organ-protective properties could render xenon an attractive anaesthetic for OPCAB surgery. The primary aim of this study was to assess whether xenon anaesthesia for OPCAB surgery is non-inferior to sevoflurane anaesthesia with regard to intraoperative vasopressor requirements. Forty-two patients undergoing elective OPCAB surgery were enrolled in this prospective, single-blind, randomized controlled pilot trial. Patients were randomized to either xenon (50-60 vol%) or sevoflurane (1.1-1.4 vol%) anaesthesia. Primary outcome was intraoperative noradrenaline requirements necessary to achieve predefined haemodynamic goals. Secondary outcomes included safety variables such as the occurrence of adverse events (intraoperatively and during a 6-month follow-up after surgery) and the perioperative cardiorespiratory and inflammatory profile. Baseline and intraoperative data did not differ between groups. Xenon was non-inferior to sevoflurane, as xenon patients required significantly less noradrenaline intraoperatively to achieve the predefined haemodynamic goals {geometric mean 428 [95% confidence interval (CI) 312, 588] vs 1702 [1267, 2285] µg, P<0.0001}. No differences were found for safety. Significantly more sevoflurane patients developed postoperative delirium (POD) (hazard ratio 4.2, P=0.044). The average arterial pressure was lower in the sevoflurane group {median75 [interquartile range (IQR) 6] vs 72 [4] mmHg, P=0.002}. No differences were found for other haemodynamic parameters, the respiratory profile and the perioperative release of inflammatory cytokines, troponin T, serum protein S-100β and erythropoietin. Compared with sevoflurane, xenon anaesthesia allows a significant reduction in vasopressor administration in OPCAB surgery. Moreover, xenon anaesthesia was associated with a lower risk for POD, a finding that has to be confirmed in larger studies. ClinicalTrials.gov (NCT01757106) and EudraCT (2012-002316-12). © The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Sutton, Steven W; Duncan, Michael A; Chase, Virginia A; Cheung, Edson H; Hamman, B L
2004-11-01
Bloodless surgery and a reduction in the use of allogeneic blood products has long been the standard of care in medicine. Many individuals in our communities have demanded this form of surgical treatment for personal and religious reasons. On 6 December 2002, a 72-year-old male patient was admitted to our institution as a critical air flight transfer. The patient's height was 190.5 cm and weight was 59.3 kg (body surface area 1.83 m2). His preliminary diagnosis was chest pain with myocardial infarction as evidenced by elevated blood cardiac isoenzymes. His principle diagnosis was subendocardial infarction with paroxysmal ventricular tachycardia. Cardiac catheterization was performed and demonstrated severe triple vessel disease with an ejection fraction of 30%. He was evaluated and accepted as a candidate for coronary artery bypass grafting. Multidisciplinary consultation concluded that a safe and effective method of perioperative treatment would involve the use of arrested heart support with cold blood cardioplegia using a low prime miniature perfusion circuit as no blood products would be considered for use. Additionally, the combined modalities of perfusion interventions to minimize hemodilution consisted of intraoperative autologous blood collection totaling 500 mL and rapid autologous priming of the miniature perfusion circuit. The miniature perfusion system was a low prime Cardiovention (Santa Clara, CA) CORx device which includes a hollow-fiber oxygenator and integral centrifugal pump with a surface area of 1.2 m2. This system also incorporates an air sensing solenoid which triggers rapid air evacuation in a bolus range of 1 mL or greater. Kinetic venous drainage is another feature of this device as the centrifugal pump is integrated into the oxygenator. We believed that a miniature extracorporeal circuit would enhance the desired clinical outcome as opposed to the risk of: (1) off-pump coronary artery bypass (OPCAB) approach and the concern of emergent transition to an on-pump procedure and (2) use of larger surface area with conventional systems that impose a greater hemodilutional effect. Leukocyte filtration was employed as the patient had a significant past medical history of chronic obstructive pulmonary disease. We herein report our clinical experience with this method of treatment on a patient who refused the use of blood products in his surgical treatment. It is our belief that the multiple modalities utilized in combination during this procedure resulted in positive clinical outcomes as demonstrated by an intubation time of 8 hours 35 min with a discharge on the fifth postoperative day.
Ichikawa, Makoto; Sato, Yuichi; Komatsu, Sei; Hirayama, Atsushi; Kodama, Kazuhisa; Saito, Satoshi
2007-06-01
Anomalous right coronary arteries (RCA) arising from the left sinus of Valsalva may cause myocardial ischemia. We evaluated morphological features of anomalous RCA by using multislice computed tomography (MSCT) in relation to myocardial ischemia provoked by myocardial perfusion single-photon emission computed tomography. MSCT was performed in a total of 3, 212 patients by using an Aquillion 16 and a Light Speed Ultra. Retrospective ECG-gated image reconstruction was performed. Volume rendering, axial and curved multiplanar reformatted images were analyzed for the determination of the origin and course of the RCA, the take-off angle of the RCA from the aorta, and size of the RCA orifice. Furthermore, virtual angioscopic images were also used for the evaluation of the RCA orifice structure. Anomalous origins of the RCA were found in 15 patients. In 13 patients, the RCA arose from the left sinus of Valsalva, and in 2 patients it arose from the left main coronary artery as a single coronary artery. The RCA coursed anteriorly between the ascending aorta and pulmonary artery in 14 patients, whereas it had a retroaortic course in 1 patient. Acute angle take-off (<30 degrees ) of the RCA from the aorta and the left main coronary artery was observed in 8 patients, intramural course of the RCA within the aortic wall was observed in 6 patients and a small RCA orifice was observed in 4 patients. Exercise-induced myocardial ischemia was present in 5 patients. Coursing between the aorta and pulmonary artery, acute angle take-off and intramural course were thought to be major causes of exercise-induced ischemia in patients with anomalous origins of the RCA.
Power consumption of rotary blood pumps: pulsatile versus constant-speed mode.
Pirbodaghi, Tohid; Cotter, Chris; Bourque, Kevin
2014-12-01
We investigated the power consumption of a HeartMate III rotary blood pump based on in vitro experiments performed in a cardiovascular simulator. To create artificial-pulse mode, we modulated the pump speed by decreasing the mean speed by 2000 rpm for 200 ms and then increasing speed by 4000 rpm (mean speeds plus 2000 rpm) for another 200 ms, creating a square waveform shape. The HeartMate III was connected to a cardiovascular simulator consisting of a hydraulic pump system to simulate left ventricle pumping action, arterial and venous compliance chambers, and an adjustable valve for peripheral resistance to facilitate the desired aortic pressure. The simulator operated based on Suga's elastance model to mimic the Starling response of the heart, thereby reproducing physiological blood flow and pressure conditions. We measured the instantaneous total electrical current and voltage of the pump to evaluate its power consumption. The aim was to answer these fundamental questions: (i) How does pump speed modulation affect pump power consumption? (ii) How does the power consumption vary in relation to external pulsatile flow? The results indicate that speed modulation and external pulsatile flow both moderately increase the power consumption. Increasing the pump speed reduces the impact of external pulsatile flow. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Liu, Xiao-Di; Xu, Lu; Liang, Xiao-Yan
2017-01-01
We theoretically analyzed output beam quality of broad bandwidth non-collinear optical parametric chirped pulse amplification (NOPCPA) in LiB3O5 (LBO) centered at 800 nm. With a three-dimensional numerical model, the influence of the pump intensity, pump and signal spatial modulations, and the walk-off effect on the OPCPA output beam quality are presented, together with conversion efficiency and the gain spectrum. The pump modulation is a dominant factor that affects the output beam quality. Comparatively, the influence of signal modulation is insignificant. For a low-energy system with small beam sizes, walk-off effect has to be considered. Pump modulation and walk-off effect lead to asymmetric output beam profile with increased modulation. A special pump modulation type is found to optimize output beam quality and efficiency. For a high-energy system with large beam sizes, the walk-off effect can be neglected, certain back conversion is beneficial to reduce the output modulation. A trade-off must be made between the output beam quality and the conversion efficiency, especially when the pump modulation is large since. A relatively high conversion efficiency and a low output modulation are both achievable by controlling the pump modulation and intensity.
Alagha, Sameh; Songur, Murat; Avci, Tugba; Vural, Kerem; Kaplan, Sadi
2018-05-15
Our primary aim was to investigate the association between the preoperative concentration of plasma fibrinogen and the volume of postoperative bleeding. Our secondary aim was to identify whether there is a possible correlation between the patients' different characteristics and haemostatic laboratory variables and the postoperative amount of bleeding after on-pump coronary artery bypass grafting procedures. A total of 550 adult patients undergoing isolated coronary artery bypass grafting on cardiopulmonary bypass in our hospital were enrolled and investigated retrospectively. The total amount of chest tube drainage within the first 24 postoperative hours or until the patient was re-explored for bleeding was assessed. Excessive bleeding was defined as more than 500 ml drainage in the first 24 h. The patients were divided into 2 groups: Group 1: the patients who bled ≤500 ml in the first 24 h and Group 2: the patients who bled >500 ml in the first 24 h. A preoperative fibrinogen threshold associated with excessive bleeding was investigated by receiver operating characteristic curve analyses, revealing a calculated cutoff value of 3.1 g/l. Risk factors for increased bleeding were analysed by a logistic regression model that revealed male gender (P < 0.001), body mass index ≤28.3 kg/m2 (P < 0.001), platelet count ≤233 × 103/µl (P < 0.001), estimated glomerular filtration rate ≤90.8 ml/min (P < 0.001) and fibrinogen ≤3.1 g/l (P = 0.01) as significant predictors. A preoperative plasma fibrinogen concentration <3.1 g/l was associated with increased risk of excessive bleeding in patients undergoing on-pump coronary artery bypass grafting. The amount of postoperative blood loss can be roughly predicted with simple preoperative blood tests.
Mechanisms of alpha 1-adrenergic vascular desensitization in conscious dogs
NASA Technical Reports Server (NTRS)
Kiuchi, K.; Vatner, D. E.; Uemura, N.; Bigaud, M.; Hasebe, N.; Hempel, D. M.; Graham, R. M.; Vatner, S. F.
1992-01-01
To investigate the mechanisms of alpha 1-adrenergic vascular desensitization, osmotic minipumps containing either saline (n = 9) or amidephrine mesylate (AMD) (n = 9), a selective alpha 1-adrenergic receptor agonist, were implanted subcutaneously in dogs with chronically implanted arterial and right atrial pressure catheters and aortic flow probes. After chronic alpha 1-adrenergic receptor stimulation, significant physiological desensitization to acute AMD challenges was observed, i.e., pressor and vasoconstrictor responses to the alpha 1-adrenergic agonist were significantly depressed (p < 0.01) compared with responses in the same dogs studied in the conscious state before pump implantation. However, physiological desensitization to acute challenges of the neurotransmitter norepinephrine (NE) (0.1 micrograms/kg per minute) in the presence of beta-adrenergic receptor blockade was not observed for either mean arterial pressure (MAP) (30 +/- 7 versus 28 +/- 5 mm Hg) or total peripheral resistance (TPR) (29.8 +/- 4.9 versus 28.9 +/- 7.3 mm Hg/l per minute). In the presence of beta-adrenergic receptor plus ganglionic blockade after AMD pump implantation, physiological desensitization to NE was unmasked since the control responses to NE (0.1 micrograms/kg per minute) before the AMD pumps were now greater (p < 0.01) than after chronic AMD administration for both MAP (66 +/- 5 versus 32 +/- 2 mm Hg) and TPR (42.6 +/- 10.3 versus 23.9 +/- 4.4 mm Hg/l per minute). In the presence of beta-adrenergic receptor, ganglionic, plus NE-uptake blockade after AMD pump implantation, desensitization was even more apparent, since NE (0.1 micrograms/kg per minute) induced even greater differences in MAP (33 +/- 5 versus 109 +/- 6 mm Hg) and TPR (28.1 +/- 1.8 versus 111.8 +/- 14.7 mm Hg/l per minute). The maximal force of contraction induced by NE in the presence or absence of endothelium was significantly decreased (p < 0.05) in vitro in mesenteric artery rings from AMD pump dogs compared with saline control dogs. Furthermore, alpha 1-adrenergic receptor density, as determined by [3H]prazosin binding in membrane preparations from vessels in the mesentery, was decreased (8.2 +/- 1.0 versus 18.4 +/- 1.4 fmol/mg protein, p < 0.001) without any change in Kd in the AMD pump dogs compared with the saline pump dogs.(ABSTRACT TRUNCATED AT 400 WORDS).
Representing pump-capacity relations in groundwater simulation models
Konikow, Leonard F.
2010-01-01
The yield (or discharge) of constant-speed pumps varies with the total dynamic head (or lift) against which the pump is discharging. The variation in yield over the operating range of the pump may be substantial. In groundwater simulations that are used for management evaluations or other purposes, where predictive accuracy depends on the reliability of future discharge estimates, model reliability may be enhanced by including the effects of head-capacity (or pump-capacity) relations on the discharge from the well. A relatively simple algorithm has been incorporated into the widely used MODFLOW groundwater flow model that allows a model user to specify head-capacity curves. The algorithm causes the model to automatically adjust the pumping rate each time step to account for the effect of drawdown in the cell and changing lift, and will shut the pump off if lift exceeds a critical value. The algorithm is available as part of a new multinode well package (MNW2) for MODFLOW.
Representing pump-capacity relations in groundwater simulati on models
Konikow, Leonard F.
2010-01-01
The yield (or discharge) of constant-speed pumps varies with the total dynamic head (or lift) against which the pump is discharging. The variation in yield over the operating range of the pump may be substantial. In groundwater simulations that are used for management evaluations or other purposes, where predictive accuracy depends on the reliability of future discharge estimates, model reliability may be enhanced by including the effects of head-capacity (or pump-capacity) relations on the discharge from the well. A relatively simple algorithm has been incorporated into the widely used MODFLOW groundwater flow model that allows a model user to specify head-capacity curves. The algorithm causes the model to automatically adjust the pumping rate each time step to account for the effect of drawdown in the cell and changing lift, and will shut the pump off if lift exceeds a critical value. The algorithm is available as part of a new multinode well package (MNW2) for MODFLOW. ?? 2009 National Ground Water Association.
Centrifugal and Axial Pump Design and Off-Design Performance Prediction
NASA Technical Reports Server (NTRS)
Veres, Joseph P.
1995-01-01
A meanline pump-flow modeling method has been developed to provide a fast capability for modeling pumps of cryogenic rocket engines. Based on this method, a meanline pump-flow code PUMPA was written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The design-point rotor efficiency and slip factors are obtained from empirical correlations to rotor-specific speed and geometry. The pump code can model axial, inducer, mixed-flow, and centrifugal pumps and can model multistage pumps in series. The rapid input setup and computer run time for this meanline pump flow code make it an effective analysis and conceptual design tool. The map-generation capabilities of the code provide the information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of PUMPA permit the user to do parametric design space exploration of candidate pump configurations and to provide head-flow maps for engine system evaluation.
Meta-Analysis of Aspirin Versus Dual Antiplatelet Therapy Following Coronary Artery Bypass Grafting.
Agarwal, Nayan; Mahmoud, Ahmed N; Patel, Nimesh Kirit; Jain, Ankur; Garg, Jalaj; Mojadidi, Mohammad Khalid; Agrawal, Sahil; Qamar, Arman; Golwala, Harsh; Gupta, Tanush; Bhatia, Nirmanmoh; Anderson, R David; Bhatt, Deepak L
2018-01-01
Although aspirin monotherapy is considered the standard of care after coronary artery bypass grafting (CABG), more recent evidence has suggested a benefit with dual antiplatelet therapy (DAPT) after CABG. We performed a meta-analysis of observational studies and randomized controlled trials comparing outcomes of aspirin monotherapy with DAPT in patients after CABG. Subgroup analyses were conducted according to surgical technique (i.e., on vs off pump) and clinical presentation (acute coronary syndrome vs no acute coronary syndrome). Random effects overall risk ratios (RR) were calculated using the DerSimonian and Laird model. Eight randomized control trials and 9 observational studies with a total of 11,135 patients were included. At a mean follow-up of 23 months, major adverse cardiac events (10.3% vs 12.1%, RR 0.84, confidence interval [CI] 0.71 to 0.99), all-cause mortality (5.7% vs 7.0%, RR 0.67, CI 0.48 to 0.94), and graft occlusion (11.3% vs 14.2%, RR 0.79, CI 0.63 to 0.98) were less with DAPT than with aspirin monotherapy. There was no difference in myocardial infarction, stroke, or major bleeding between the 2 groups. In conclusion, DAPT appears to be associated with a reduction in graft occlusion, major adverse cardiac events, and all-cause mortality, without significantly increasing major bleeding compared with aspirin monotherapy in patients undergoing CABG. Copyright © 2017 Elsevier Inc. All rights reserved.
Analysis of intra-aortic balloon pump model with ovine myocardial infarction.
Abdolrazaghi, Mona; Navidbakhsh, Mahdi; Hassani, Kamran; Rabbani, Shahram; Ahmadi, Hossein
2009-12-01
In this study, we have tried to model the effects of intra-aortic balloon pump (IABP) on myocardial infarction (MI) using the standardized data of MI in sheep which was obtained by ligation of the left anterior descending coronary artery. Mathematical model of whole cardiovascular system was presented in accordance to the arterial tree. The lumped parameter model was primarily obtained for a rigid vessel regarding the vessel diameter. In this study, the proper lumped model of every vessel was obtained by incorporating the rigid vessel lumped model into the capacitance as a compliance of the vessel. Intra-aortic balloon pump was modeled with the hemodynamic parameters of the aorta. It was assumed that balloon pump inflates at the beginning of the diastole and deflates near the beginning of the next systole. During balloon pumping, the vessel diameter variation function counter pulsates sinusoidally with the same period of the cardiac cycle. End systolic pressure and end diastolic pressure decreases along with hemodynamic flow optimized through systemic arteries due to balloon pumping in diastole. It has been shown that the blood flow in subclavian artery increases as well. Moreover, the cardiac work keeps low, which prone to lower oxygen consumption. The results of modeling are in good agreement with IABP documentation. The presented model is a useful tool for studying of the cardiovascular system pathology and the presented modeling data are in good agreement with the experimental ones.
NASA Astrophysics Data System (ADS)
Ogino, Jumpei; Miyamoto, Sho; Matsuyama, Takahiro; Sueda, Keiichi; Yoshida, Hidetsugu; Tsubakimoto, Koji; Miyanaga, Noriaki
2014-12-01
We demonstrate optical parametric chirped-pulse amplification (OPCPA) based on two-beam pumping, using sub-nanosecond pulses generated by stimulated Brillouin scattering compression. Seed pulse energy, duration, and center wavelength were 5 nJ, 220 ps, and ˜1065 nm, respectively. The 532 nm pulse from a Q-switched Nd:YAG laser was compressed to ˜400 ps in heavy fluorocarbon FC-40 liquid. Stacking of two time-delayed pump pulses reduced the amplifier gain fluctuation. Using a walk-off-compensated two-stage OPCPA at a pump energy of 34 mJ, a total gain of 1.6 × 105 was obtained, yielding an output energy of 0.8 mJ. The amplified chirped pulse was compressed to 97 fs.
Performance of a solar augmented heat pump
NASA Astrophysics Data System (ADS)
Bedinger, A. F. G.; Tomlinson, J. J.; Reid, R. L.; Chaffin, D. J.
Performance of a residential size solar augmented heat pump is reported for the 1979-1980 heating season. The facility located in Knoxville, Tennessee, has a measured heat load coefficient of 339.5 watt/C (644 BTU/hr- F). The solar augmented heat pump system consists of 7.4 cu m of one inch diameter crushed limestone. The heat pump is a nominal 8.8 KW (2 1/2 ton) high efficiency unit. The system includes electric resistance heaters to give the option of adding thermal energy to the pebble bed storage during utility off-peak periods, thus offering considerable load management capability. A 15 KW electric resistance duct heater is used to add thermal energy to the pebble bin as required during off-peak periods. Hourly thermal performance and on site weather data was taken for the period November 1, 1979, to April 13, 1980. Thermal performance data consists of heat flow summations for all modes of the system, pebble bed temperatures, and space temperature. Weather data consists of dry bulb temperature, dew point temperature, total global insolation (in the plane of the collector), and wind speed and direction. An error analysis was performed and the least accurate of the measurements was determined to be the heat flow at 5%. Solar system thermal performance factor was measured to be 8.77. The heat pump thermal performance factor was 1.64. Total system seasonal performance factor was measured to be 1.66. Using a modified version of TRNSYS, the thermal performance of this system was simulated. When simulation results were compared with data collected onsite, the predicted heat flow and power consumption generally were within experimental accuracy.
Tołwińska, Joanna; Głowińska-Olszewska, Barbara; Urban, Mirosława; Florys, Bozena; Peczyńska, Jadwiga
2006-01-01
Type 1 diabetes is a known risk factor for arterial atherosclerosis. The first symptoms can be found even in childhood. The ultrasonographic measurements of intimal plus medial thickness in carotid arteries (IMT) and flow mediated dilatation (FMD) evaluated in brachial arteries, play a known role in the detection in these cases. The diabetes treatment intensification is an important factor in delaying early atherosclerotic changes. Currently, intensive treatment of children's diabetes with use of continuous subcutaneous insulin infusion with personal insulin pumps is gaining more and more popularity. THE AIM OF THIS STUDY was the evaluation of IMT and FMD indexes in children suffering from type 1 diabetes in the context of treatment intensification (multidose insulin injections v. personal insulin pumps). We examined 64 children (29 boys and 35 girls) in the mean age 15.5 years treated with the multidose insulin injections method and 10 children using personal insulin pumps (4 girls and 6 boys) in the mean age 14.5 years. Using high resolution ultrasonography we evaluated IMT values in carotid arteries and FMD parameters in brachial arteries. In our analysis we estimated the blood concentration of lipid parameters, values of systolic and diastolic blood pressure, the age of diabetes onset, duration time of the illness and the values of HbA1c as a marker of metabolic control. We noticed significantly higher FMD values in patients treated with personal insulin pumps (13.7 vs. 5.5%, p=0.001). IMT values were similar in both groups (0.52 vs. 0.5 mm, p=0. 41). The level of HDL cholesterol was higher and triglycerides lower in the group with treatment intensification. The metabolic control was the same in both groups. In patients treated by the multidose insulin injections IMT correlated with systolic blood pressure values. We didn't notice any correlation between IMT and FMD in any group. 1. Treatment intensification (personal insulin pumps) influences better vascular endothelial function in type 1 diabetic children and seems to be a significant tool in delaying the atherosclerotic process. 2. We need more examinations to explain the role of treatment intensification in common carotid arteries wall morphology in type 1 diabetic children. 3. The ultrasonographic detection of atherosclerotic changes in arterial vessels can help in the evaluation of the changes due to different methods of diabetes treatment.
Willaert, Wouter; Tozzi, Francesca; Van Hoof, Tom; Ceelen, Wim; Pattyn, Piet; D''Herde, Katharina
2016-01-01
Vascular reperfusion of Thiel cadavers can aid surgical and anatomical instruction. This study investigated whether ideal embalming circumstances provide lifelike vascular flow, enabling surgical practice and enhancing anatomical reality. Pressure-controlled pump-driven administration of blue embalming solution was assessed directly postmortem in a pig model (n = 4). Investigation of subsequent pump-driven vascular injection of red paraffinum perliquidum (PP) included assessment of flow parameters, intracorporeal distribution, anatomical alterations, and feasibility for surgical training. The microscopic distribution of PP was analyzed in pump-embalmed pig and gravity-embalmed human small intestines. Embalming lasted 50-105 min, and maximum arterial pressure was 65 mm Hg. During embalming, the following consecutive alterations were observed: arterial filling, organ coloration, venous perfusion, and further tissue coloration during the next weeks. Most organs were adequately preserved. PP generated low arterial pressures (<30 mm Hg) and drained through the venous cannula. Generally, realistic reperfusion and preservation of original anatomy were observed, but leakage in the pleural, abdominal, and retroperitoneal cavities occurred, and computed tomography showed edematous spleen and liver. Reduction of arterial flow rates after venous drainage is a prerequisite to prevent anatomical deformation, allowing simulation of various surgeries. In pump-embalmed pig small intestines, PP flowed from artery to vein through the capillaries without extravasation. In contrast, arterioles were blocked in gravity-embalmed human tissues. In a pig model, immediate postmortem pressure-controlled pump embalming generates ideal circumstances for (micro)vascular reperfusion with PP, permitting lifelike anatomy instruction and surgical training. © 2016 S. Karger AG, Basel.
Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton
2015-02-01
The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and substantially reduced the arterial pressure upon HUT. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
28. PUMP/ENGINE ROOM OFF THE BASEMENT OF MILL NO. 1. ...
28. PUMP/ENGINE ROOM OFF THE BASEMENT OF MILL NO. 1. ENGINE PLATFORM IS SEEN BEHIND PUMP. THIS AMERICAN MOISTURE CO. PUMP WAS USED TO HUMIDIFY UPPER FLOORS OF MILL. NOTE TANK TO LEFT, UNKNOWN USE. NOTHING IN THIS ROOM HAS BEEN USED SINCE 1945. - Prattville Manufacturing Company, Number One, 242 South Court Street, Prattville, Autauga County, AL
[Cardiovascular effects of prostaglandin F 2 alpha in early pregnancy].
Retzke, U; Schwarz, R
1976-01-01
In 10 normotensive healthy early pregnant women cardiovascular studies were done before, during and after the intravenous administration of prostaglandin F2alpha with the method of quantitative sphygmometry. Arterial blood pressure was measured graphically with an automatic sphygmomanometer unit. Velocity of aortic pulse wave was determined directly on the principle of exact electronic timing. Prostaglandin F2alpha was infused with electric pump in the dosage of 6, 5, 13 and 26 mug per minute for 30 minutes in each case. Arterial blood pressure is nearly constant. Heart rate, the elasticity coefficient of the arteries E' and total peripheral resistance decreases significantly. Stroke volume, cardiac output, work and power of the heart increases significantly. Nevertheless there are no contra-indications on the part of cardiovascular system for using prostaglandin F2alpha for induction of abortion
2013-01-01
after pump calibrations , transfer pump blade measurements, injector nozzle tests, pump parts evaluation, and parts conditions photographs are also... Injectors –0 0.53 5,500 0.257 1 2-15293089 DF2 As Purchased 105 (40) 1,000 1,000 Calibration off spec areas–4 Pump Rating–1.04 Failed Injectors –0 0.53...5,500 0.257 2 1-15382732 DF2 As Purchased 135 (57) 1,000 1,000 Calibration off spec areas–4 Pump Rating–1.13 Failed Injectors –0 0.55
Selective reduction of afterload in right heart assist therapy: a mock loop study†.
Hsu, Po-Lin; Hatam, Nima; Unterkofler, Jan; Goetzenich, Andreas; McIntyre, Madeleine; Wong, Kai Chun; Egger, Christina; Schmitz-Rode, Thomas; Autschbach, Rüdiger; Steinseifer, Ulrich
2014-07-01
The treatment of right ventricular failure is closely linked to effects on pulmonary vascular resistance and thus the right ventricular (RV) afterload. Medical therapy includes afterload-decreasing drugs such as nitric oxide and prostacycline. However, current devices for mechanical unloading of the right ventricle aim at a decrease in preload increasing the pulmonary volume loading. In our concept study, we tested a minimally invasive right ventricular assist device (MIRVAD) that specifically reduces the afterload. The MIRVAD is supposed to be a foldable device for temporary transvascular placement in the pulmonary artery. We incorporated a MIRVAD prototype into a mock circulatory loop that can reproduce haemodynamic interaction between the pump and the physiological system. Pulmonary hypertension (PH), right heart failure (RHF) and MIRVAD-assisted cases were simulated. The key haemodynamic parameters for RV unloading were recorded. Mock loop simulation attested to a sufficient right ventricular unloading by serial application of a miniaturized impeller pump in the pulmonary artery. The afterload, represented by the pulmonary arterial root pressure, was recovered to the healthy range (32.62-10.93 mmHg) for the simulated PH case. In the simulated RHF case, the impaired pulmonary perfusion increased from 43.4 to 88.8% of the healthy level and the total ventricular work reduced from 0.381 to 0.197 J at a pump speed of 3500 rpm. At pump speeds higher than 3500 rpm, the pulmonary valve remains constantly open and the right ventricular configuration changes into a simple perfused hollow body. The feasibility of RV unloading by a selective decrease in RV afterload was proved in principle. By alternation of the pump speed, gradual reloading in sense of a myocardial training may be achieved. The results will be validated by future animal trials where the relationship between the level of support and pulmonary vascular pressure can be investigated in vivo. Further device design concerning foldable impeller leaflets will be carried out. At a final stage, the crimped version is supposed to reach a size below 1 cm to facilitate minimally invasive insertion. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Lima, Reijane Oliveira; Borges, Daniel Lago; Costa, Marina de Albuquerque Gonçalves; Baldez, Thiago Eduardo Pereira; Silva, Mayara Gabrielle Barbosa e; Sousa, Felipe André Silva; Soares, Milena de Oliveira; Pinto, Jivago Gentil Moreira
2015-01-01
Introduction After removal of endotracheal tube and artificial ventilation, ventilatory support should be continued, offering oxygen supply to ensure an arterial oxygen saturation close to physiological. Objective The aim of this study was to investigate the effects of positive-end expiratory pressure before extubation on the oxygenation indices of patients undergoing coronary artery bypass grafting. Methods A randomized clinical trial with seventy-eight patients undergoing coronary artery bypass grafting divided into three groups and ventilated with different positive-end expiratory pressure levels prior to extubation: Group A, 5 cmH2O (n=32); Group B, 8 cmH2O (n=26); and Group C, 10 cmH2O (n=20). Oxygenation index data were obtained from arterial blood gas samples collected at 1, 3, and 6 h after extubation. Patients with chronic pulmonary disease and those who underwent off-pump, emergency, or combined surgeries were excluded. For statistical analysis, we used Shapiro-Wilk, G, Kruskal-Wallis, and analysis of variance tests and set the level of significance at P<0.05. Results Groups were homogenous with regard to demographic, clinical, and surgical variables. There were no statistically significant differences between groups in the first 6 h after extubation with regard to oxygenation indices and oxygen therapy utilization. Conclusion In this sample of patients undergoing coronary artery bypass grafting, the use of different positive-end expiratory pressure levels before extubation did not affect gas exchange or oxygen therapy utilization in the first 6 h after endotracheal tube removal. PMID:27163418
Ohtsuka, Toshiya; Ninomiya, Mikio; Nonaka, Takahiro
2009-07-01
: A pedicled prepericardial fat flap was created to augment the pericardial cavity and applied for patients undergoing coronary artery bypass grafting. The efficacy and durability of this method were investigated. : Between July 2005 and November 2008, the present technique was applied for consecutive 245 patients (165 men and 80 women, aged 67 ± 8.3 years) undergoing isolated coronary artery bypass grafting in which 240 (98.0%) were off-pump cases. The left and/or right internal thoracic artery and the gastroepiploic artery were used in 244 and 160 patients, respectively, and the saphenous vein and the radial artery were used in 51 and 10 patients, respectively. Ninety-seven (40.0%) patients had been diabetic, 18 (7.3%) had had chronic renal failure, and three were redo cases. The prepericardial soft tissue, involving the pedicled thymic gland, was dissected en bloc and sewn with pericardiotomies to wrap the heart and the grafts. Angiography or three-dimensional computed tomography was used to assess the intrapericardial pathways of each graft and a long-term durability of the fat pad. : Early angiography or three-dimensional computed tomography proved that the graft pathways were unaffected by the encasements. Resternotomies in two patients and sternal treatments for infectious dehiscence in two patients were safely achievable. Five-year postoperative computed tomography showed the intact fat pad in the retrosternal space. : The present technique can encase the heart not the least jeopardizing each pathway of the grafts, and the durable fat pad functions protectively when the sternotomy is either reopened or infected.
Impact of Spatial Pumping Patterns on Groundwater Management
NASA Astrophysics Data System (ADS)
Yin, J.; Tsai, F. T. C.
2017-12-01
Challenges exist to manage groundwater resources while maintaining a balance between groundwater quantity and quality because of anthropogenic pumping activities as well as complex subsurface environment. In this study, to address the impact of spatial pumping pattern on groundwater management, a mixed integer nonlinear multi-objective model is formulated by integrating three objectives within a management framework to: (i) maximize total groundwater withdrawal from potential wells; (ii) minimize total electricity cost for well pumps; and (iii) attain groundwater level at selected monitoring locations as close as possible to the target level. Binary variables are used in the groundwater management model to control the operative status of pumping wells. The NSGA-II is linked with MODFLOW to solve the multi-objective problem. The proposed method is applied to a groundwater management problem in the complex Baton Rouge aquifer system, southeastern Louisiana. Results show that (a) non-dominated trade-off solutions under various spatial distributions of active pumping wells can be achieved. Each solution is optimal with regard to its corresponding objectives; (b) operative status, locations and pumping rates of pumping wells are significant to influence the distribution of hydraulic head, which in turn influence the optimization results; (c) A wide range of optimal solutions is obtained such that decision makers can select the most appropriate solution through negotiation with different stakeholders. This technique is beneficial to finding out the optimal extent to which three objectives including water supply concern, energy concern and subsidence concern can be balanced.
Shim, J-K; Yang, S-Y; Yoo, Y-C; Yoo, K-J; Kwak, Y-L
2013-01-01
The aim of this randomized and controlled trial was to investigate the effect of a glucose-insulin-potassium (GIK) solution on myocardial protection in acute coronary syndrome (ACS) patients undergoing urgent multivessel off-pump coronary artery bypass (OPCAB) surgery. Sixty-six patients were randomly allocated either to receive 0.3 ml kg(-1) h(-2) GIK solution (potassium 80 mEq and regular insulin 325 IU in 500 ml of 50% glucose) or equivalent volume of normal saline (control) upon anaesthetic induction until 6 h after reperfusion. The primary endpoints were to compare the concentrations of creatine kinase-MB (CK-MB) and troponin-T between the groups after reperfusion. The secondary endpoints were to compare the incidences of postoperative troponin-T >0.8 ng ml(-1) and myocardial infarction (MI) between the groups. Highest CK-MB [8.7 (4.4) vs 13.1 (7.9) ng ml(-1), P=0.006] and troponin-T [0.20 (0.13-0.49) vs 0.48 (0.18-0.91) ng ml(-1), P<0.0001] values after reperfusion were significantly lower in the GIK group compared with the control group. The area under the curve of serially measured troponin-T was also significantly smaller in the GIK group compared with the control group [0.83 (0.43-1.81) vs 0.46 (0.31-1.00), P=0.036]. Significantly fewer patients in the GIK group showed troponin-T >0.8 ng ml(-1) after reperfusion compared with the control group (3 vs 11, P=0.033). The incidence of postoperative MI was similar between the groups. GIK administration in ACS patients undergoing urgent multivessel OPCAB significantly attenuated the degree of ensuing myocardial injury without complications related to glycaemic control. Clinical Trial Registry. URL: http://clinicaltrials.gov/ct2/show/NCT01384656?term=GIK+AND+OPCAB&rank=1. Unique identification number NCT01384656.
Benedetto, Umberto; Ng, Colin; Frati, Giacomo; Biondi-Zoccai, Giuseppe; Vitulli, Piergiusto; Zeinah, Mohamed; Raja, Shahzad G
2015-02-01
Controversies exist whether off-pump coronary artery bypass (OPCAB) is superior to miniaturized extracorporeal circulation (MECC) in reducing deleterious effects of cardiopulmonary bypass as only a number of smaller randomized controlled trials (RCT) currently provide a limited evidence base. The main purpose of conducting the present meta-analysis was to overcome the expected low power in RCTs in an attempt to establish whether MECC is comparable to OPCAB. A MEDLINE/PubMed search was conducted to identify eligible RCTs. A pooled summary effect estimate was calculated by means of Mantel-Haenszel method. The search yielded 7 RCTs included in this meta-analysis enrolling 271 patients in the OPCAB group and 279 in the MECC group. The OPCAB and MECC groups were comparable in terms of incidence of in-hospital mortality (Risk Difference [RD] 0.01; 95%CI -0.02, 0.03; P = 0.55; I(2) = 0%), stroke (RD -0.01; 95%CI -0.05, 0.04; P = 0.69; I(2) = 0%), need for renal replacement therapy (RD 0.00; -0.06, 0.06; P = 1; I(2) = 0%), postoperative atrial fibrillation (RD -0.03; -0.17, 0.10; P = 0.64; I(2) = 0%), re-exploration for bleeding (RD -0.01; 95%CI -0.03, 0.02; P = 0.65; I(2) = 0%), transfusion rate (RD -0.01; 95%CI -0.03, 0.02; P = 0.65; I(2) = 0%) and the amount of blood loss (weighted mean difference -25 mL; 95%CI -71, 21; P = 0.28; I(2) = 0%). Using a meta-analytic approach, MECC achieves clinical results comparable to OPCAB including postoperative blood loss and blood transfusion requirement. On the basis of our findings, MECC should be considered as a valid alternative to OPCAB in order to reduce surgical morbidity of conventional cardiopulmonary bypass. Copyright © 2015 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.
Ji, Qiang; Xia, Li Min; Shi, Yun Qing; Ma, Run Hua; Shen, Jin Qiang; Ding, Wen Jun; Wang, Chun Sheng
2017-10-10
Few studies focused on evaluating the impacts of preoperative severe left ventricular dysfunction on clinical outcomes of patients undergoing off-pump coronary artery bypass grafting surgery (OPCAB). This single center retrospective study aimed to evaluate the impacts of severe left ventricular dysfunction on in-hospital and mid-term clinical outcomes of Chinese patients undergoing first, scheduled, and isolated OPCAB surgery. From January 2010 to December 2014, 2032 eligible patients were included in this study and were divided into 3 groups: a severe group (patients with preoperative left ventricular ejection fraction (LVEF) of ≤35%, n = 128), an impaired group (patients with preoperative LVEF of 36-50%, n = 680), and a normal group (patients with preoperative LVEF of >50%, n = 1224). In-hospital and follow-up clinical outcomes were investigated and compared. Patients in the severe group compared to the other 2 groups had higher in-hospital mortality and higher incidences of low cardiac output and prolonged ventilation. Kaplan-Meier curves showed a similar cumulative follow-up survival between the severe group and the impaired group (χ 2 = 1.980, Log-rank p = 0.159) and between the severe group and the normal group (χ 2 = 2.701, Log-rank p = 0.102). Multivariate Cox regression indicated that grouping was not a significant variable related to mid-term all-cause mortality. No significant difference was found in the rate of repeat revascularization between the severe group (2.4%) and the other 2 groups. Patients with preoperative LVEF of ≤35% compared to preoperative LVEF of >35% increased the risk of in-hospital death and incidences of postoperative low cardiac output and prolonged ventilation, but shared similar mid-term all-cause mortality and repeat revascularization after OPCAB surgery.
An effective fractal-tree closure model for simulating blood flow in large arterial networks.
Perdikaris, Paris; Grinberg, Leopold; Karniadakis, George Em
2015-06-01
The aim of the present work is to address the closure problem for hemodynamic simulations by developing a flexible and effective model that accurately distributes flow in the downstream vasculature and can stably provide a physiological pressure outflow boundary condition. To achieve this goal, we model blood flow in the sub-pixel vasculature by using a non-linear 1D model in self-similar networks of compliant arteries that mimic the structure and hierarchy of vessels in the meso-vascular regime (radii [Formula: see text]). We introduce a variable vessel length-to-radius ratio for small arteries and arterioles, while also addressing non-Newtonian blood rheology and arterial wall viscoelasticity effects in small arteries and arterioles. This methodology aims to overcome substantial cut-off radius sensitivities, typically arising in structured tree and linearized impedance models. The proposed model is not sensitive to outflow boundary conditions applied at the end points of the fractal network, and thus does not require calibration of resistance/capacitance parameters typically required for outflow conditions. The proposed model convergences to a periodic state in two cardiac cycles even when started from zero-flow initial conditions. The resulting fractal-trees typically consist of thousands to millions of arteries, posing the need for efficient parallel algorithms. To this end, we have scaled up a Discontinuous Galerkin solver that utilizes the MPI/OpenMP hybrid programming paradigm to thousands of computer cores, and can simulate blood flow in networks of millions of arterial segments at the rate of one cycle per 5 min. The proposed model has been extensively tested on a large and complex cranial network with 50 parent, patient-specific arteries and 21 outlets to which fractal trees where attached, resulting to a network of up to 4,392,484 vessels in total, and a detailed network of the arm with 276 parent arteries and 103 outlets (a total of 702,188 vessels after attaching the fractal trees), returning physiological flow and pressure wave predictions without requiring any parameter estimation or calibration procedures. We present a novel methodology to overcome substantial cut-off radius sensitivities.
An efective fractal-tree closure model for simulating blood flow in large arterial networks
Perdikaris, Paris; Grinberg, Leopold; Karniadakis, George Em.
2014-01-01
The aim of the present work is to address the closure problem for hemodynamic simulations by developing a exible and effective model that accurately distributes flow in the downstream vasculature and can stably provide a physiological pressure out flow boundary condition. To achieve this goal, we model blood flow in the sub-pixel vasculature by using a non-linear 1D model in self-similar networks of compliant arteries that mimic the structure and hierarchy of vessels in the meso-vascular regime (radii 500 μm – 10 μm). We introduce a variable vessel length-to-radius ratio for small arteries and arterioles, while also addressing non-Newtonian blood rheology and arterial wall viscoelasticity effects in small arteries and arterioles. This methodology aims to overcome substantial cut-off radius sensitivities, typically arising in structured tree and linearized impedance models. The proposed model is not sensitive to out flow boundary conditions applied at the end points of the fractal network, and thus does not require calibration of resistance/capacitance parameters typically required for out flow conditions. The proposed model convergences to a periodic state in two cardiac cycles even when started from zero-flow initial conditions. The resulting fractal-trees typically consist of thousands to millions of arteries, posing the need for efficient parallel algorithms. To this end, we have scaled up a Discontinuous Galerkin solver that utilizes the MPI/OpenMP hybrid programming paradigm to thousands of computer cores, and can simulate blood flow in networks of millions of arterial segments at the rate of one cycle per 5 minutes. The proposed model has been extensively tested on a large and complex cranial network with 50 parent, patient-specific arteries and 21 outlets to which fractal trees where attached, resulting to a network of up to 4,392,484 vessels in total, and a detailed network of the arm with 276 parent arteries and 103 outlets (a total of 702,188 vessels after attaching the fractal trees), returning physiological flow and pressure wave predictions without requiring any parameter estimation or calibration procedures. We present a novel methodology to overcome substantial cut-off radius sensitivities PMID:25510364
Cerebral hemodynamics with intra-aortic balloon pump: business as usual?
Caldas, J R; Panerai, R B; Bor-Seng-Shu, E; Almeida, J P; Ferreira, G S R; Camara, L; Nogueira, R C; Oliveira, M L; Jatene, F B; Robinson, T G; Hajjar, L A
2017-06-22
Intra-aortic balloon pump (IABP) is commonly used as mechanical support after cardiac surgery or cardiac shock. Although its benefits for cardiac function have been well documented, its effects on cerebral circulation are still controversial. We hypothesized that transfer function analysis (TFA) and continuous estimates of dynamic cerebral autoregulation (CA) provide consistent results in the assessment of cerebral autoregulation in patients with IABP. Continuous recordings of blood pressure (BP, intra-arterial line), end-tidal CO 2 , heart rate and cerebral blood flow velocity (CBFV, transcranial Doppler) were obtained (i) 5 min with IABP ratio 1:3, (ii) 5 min, starting 1 min with the IABP-ON, and continuing for another 4 min without pump assistance (IABP-OFF). Autoregulation index (ARI) was estimated from the CBFV response to a step change in BP derived by TFA and as a function of time using an autoregressive moving-average model during removal of the device (ARI t ). Critical closing pressure and resistance area-product were also obtained. ARI with IABP-ON (4.3 ± 1.2) were not different from corresponding values at IABP-OFF (4.7 ± 1.4, p = 0.42). Removal of the balloon had no effect on ARI t , CBFV, BP, cerebral critical closing pressure or resistance area-product. IABP does not disturb cerebral hemodynamics. TFA and continuous estimates of dynamic CA can be used to assess cerebral hemodynamics in patients with IABP. These findings have important implications for the design of studies of critically ill patients requiring the use of different invasive support devices.
Hydrologic trade-offs in conjunctive use management.
Bredehoeft, John
2011-01-01
An aquifer, in a stream/aquifer system, acts as a storage reservoir for groundwater. Groundwater pumping creates stream depletion that recharges the aquifer. As wells in the aquifer are moved away from the stream, the aquifer acts to filter out annual fluctuations in pumping; with distance the stream depletion tends to become equal to the total pumping averaged as an annual rate, with only a small fluctuation. This is true for both a single well and an ensemble of wells. A typical growing season in much of the western United States is 3 to 4 months. An ensemble of irrigation wells spread more or less uniformly across an aquifer several miles wide, pumping during the growing season, will deplete the stream by approximately one-third of the total amount of water pumped during the growing season. The remaining two-thirds of stream depletion occurs outside the growing season. Furthermore, it takes more than a decade of pumping for an ensemble of wells to reach a steady-state condition in which the impact on the stream is the same in succeeding years. After a decade or more of pumping, the depletion is nearly constant through the year, with only a small seasonal fluctuation: ±10%. Conversely, stream depletion following shutting down the pumping from an ensemble of wells takes more than a decade to fully recover from the prior pumping. Effectively managing a conjunctive groundwater and surface water system requires integrating the entire system into a single management institution with a long-term outlook. Copyright © 2010 The Author(s). Journal compilation © 2010 National Ground Water Association.
Negi, Smita I; Sokolovic, Mladen; Koifman, Edward; Kiramijyan, Sarkis; Torguson, Rebecca; Lindsay, Joseph; Ben-Dor, Itsik; Suddath, William; Pichard, Augusto; Satler, Lowell; Waksman, Ron
2016-02-01
Refractory cardiogenic shock (RCS) in acute myocardial infarction (AMI) is associated with high rates of mortality. Smaller ventricular assist devices, such as the intraaortic balloon pump, provide limited support. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) offers more robust mechanical ventricular support, but is not widely utilized by interventional cardiologists. This study aimed to evaluate the patient characteristics and outcomes of VA-ECMO with RCS in the setting of AMI. A retrospective chart review of all VA-ECMO cannulations between 2009 and 2014 was performed, and patients with an indication of RCS in AMI were identified. A total of 15 patients underwent VA-ECMO placement for AMI with RCS. One-third of these patients presented with out-of-hospital cardiac arrest, and 60% had ST-elevation myocardial infarction. The Intraaortic balloon pump was placed in addition to VA-ECMO in 60% of patients. Median duration of VA-ECMO support was 45 hours. Successful wean off VA-ECMO was obtained in 50% of the patients, and vascular complications occurred in 53% of patients. The survival rate at discharge was 47%, and all survivors were alive at 30 days post discharge. VA-ECMO is infrequently used in patients for cardiopulmonary resuscitation in the AMI setting. When used judiciously, it has good clinical outcomes in this group of patients. However, use of VA-ECMO should be individualized based on vascular anatomy for best results. Close cooperation among interventional cardiologists, cardiovascular surgeons, cardiologists, cardiac intensivists, and perfusionists is essential for success of this therapy for RCS in AMI.
Hwang, Ho Young; Kim, Jun Sung; Oh, Se Jin; Kim, Ki-Bong
2012-11-01
The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft trial was designed to evaluate the saphenous vein compared with the right internal thoracic artery as a Y-composite graft anastomosed to the side of the left internal thoracic artery. In this early analysis, we compared early angiographic patency rates and clinical outcomes. From September 2008 to October 2011, 224 patients with multivessel coronary artery disease were randomized prospectively to undergo off-pump revascularization using the saphenous vein group (n = 112) or the right internal thoracic artery group (n = 112) as Y-composite grafts. Early postoperative (1.4 ± 1.1 days) angiographic patency and clinical outcomes were compared. There was 1 operative death in the right internal thoracic artery group. No statistically significant differences in postoperative morbidities, including atrial fibrillation and acute renal failure, were observed between the groups. The number of distal anastomoses using the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 2.3 ± 0.8 and 1.9 ± 0.7 in the saphenous vein and right internal thoracic artery groups, respectively (P < .001). A third conduit was used in 44 patients (saphenous vein group vs right internal thoracic artery group, 4/109 vs 40/110; P < .001) to extend the side-arm Y-composite graft for complete revascularization. Early angiography demonstrated an overall patency rate of 99.4% (771 of 776 distal anastomoses). Patency rates of the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 98.8% (245 of 248) and 99.5% (207 of 208) in the saphenous vein and right internal thoracic artery groups, respectively (P = .629). A third conduit was needed to extend the right internal thoracic artery composite graft and reach the target vessels in 36.4% (40/110) of the patients. The saphenous vein composite graft was comparable with the right internal thoracic artery composite graft in terms of early angiographic patency and clinical outcomes. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
[Methods for exposure of recurrent laryngeal nerve in thyroid surgery].
Ma, Xiangdong; Han, Xilin; Liu, Tao; Kou, Changhua
2014-10-01
To evaluate different methods to explose recurrent laryngeal nerve (RLN) based on the location of thyroid diseses and anatomic path of the RLN, to avoid the RLN damage in thyroid surgery. A total of 755 cases underwent total lobectomy was studied retrospectively. RLN was explosed in each case. A total of 963 RLN was exposed in 755 cases, among those 658 RLN were exposed by lateral approach, 106 by inferior approach, and 199 by superior approach. It was showed that 694 RLN traveled deep to the inferior throid artery and 119 superficial to the artery, 98 through between two branches of the artery, and 62 with the cross of the nerve branches and the artery branches. Before entering larynx, 578 RLN gave off branches and 385 had no branches. Non-recurrent laryngeal nerves were found in 2 cases. There were 6 cases who presented with hoarseness after thyroidectomy and undergoing reexploration, among them RLN were legated in 4 cases and severed in 2 cases. The anatomic relation of RLN is relatively complicated. Lateral, inferior or superior aproach may be used for exposure of RLN to decrease risks of injury to the nerve.
Celtikci, Pinar; Ergun, Onur; Durmaz, Hasan Ali; Conkbayir, Isik; Hekimoglu, Baki
2017-09-01
To determine the frequency of popliteal artery branching variations in a wide study cohort and to investigate the relationship between these variations and infrapopliteal peripheral arterial disease (PAD). A subclassification was proposed for the most encountered type I-A, utilizing tibio-fibular trunk (TFT) length. A total number of 1184 lower extremity digital subtraction angiography (DSA) studies of 669 patients were evaluated. Following exclusion, 863 lower extremity DSA studies (431 right, 432 left) of 545 patients were enrolled. Popliteal artery branching type, patency of anterior tibial artery (ATA), fibular artery (FA) and posterior tibial artery (PTA) in each extremity and TFT length for type I-A extremities were recorded. Percentages of branching patterns, mean length and cut-off value of TFT and incidence of PAD in different types of branching were calculated. Type I-A was the most common type of branching (81.3%). Frequency of branching pattern variation was 18.7%, the most common variation category was category III (12.2%) and the most common variation type was type III-A (5.6%). ATA and PTA had higher percentages of PAD in extremities with variant branching types. Cut-off value of 3 cm for TFT length was proposed in order to subclassify type I-A. Our study cohort presents a higher incidence of popliteal artery branching variations. Some branching variations might have effect on the involvement pattern of the infrapopliteal arteries by PAD. We propose a subclassification for type I-A; type I-A-S (TFT < 3 cm) and type I-A-L (TFT ≥ 3 cm) which might have impact on interventional procedures.
Cornwell, William K; Tarumi, Takashi; Stickford, Abigail; Lawley, Justin; Roberts, Monique; Parker, Rosemary; Fitzsimmons, Catherine; Kibe, Julius; Ayers, Colby; Markham, David; Drazner, Mark H; Fu, Qi; Levine, Benjamin D
2015-12-15
Current-generation left ventricular assist devices provide circulatory support that is minimally or entirely nonpulsatile and are associated with marked increases in muscle sympathetic nerve activity (MSNA), likely through a baroreceptor-mediated pathway. We sought to determine whether the restoration of pulsatile flow through modulations in pump speed would reduce MSNA through the arterial baroreceptor reflex. Ten men and 3 women (54 ± 14 years) with Heartmate II continuous-flow left ventricular assist devices underwent hemodynamic and sympathetic neural assessment. Beat-to-beat blood pressure, carotid ultrasonography at the level of the arterial baroreceptors, and MSNA via microneurography were continuously recorded to determine steady-state responses to step changes (200-400 revolutions per minute) in continuous-flow left ventricular assist device pump speed from a maximum of 10,480 ± 315 revolutions per minute to a minimum of 8500 ± 380 revolutions per minute. Reductions in pump speed led to increases in pulse pressure (high versus low speed: 17 ± 7 versus 26 ± 12 mm Hg; P<0.01), distension of the carotid artery, and carotid arterial wall tension (P<0.05 for all measures). In addition, MSNA was reduced (high versus low speed: 41 ± 15 versus 33 ± 16 bursts per minute; P<0.01) despite a reduction in mean arterial pressure and was inversely related to pulse pressure (P=0.037). Among subjects with continuous-flow left ventricular assist devices, the restoration of pulsatile flow through modulations in pump speed leads to increased distortion of the arterial baroreceptors with a subsequent decline in MSNA. Additional study is needed to determine whether reduction of MSNA in this setting leads to improved outcomes. © 2015 American Heart Association, Inc.
Oilwell Power Controller (OPC)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-08-01
The Oil Well Power Controller (OPC) prototype units is nearing completion. This device is an oilwell beam pump controller and data logger. Applications for this device have been for an electrical power saving device, pump off control, parafffin detection, demand power load control, chemical treatment data, dynamometer and pump efficiency data. Preliminary results appear vary promising. A total of ten OPC rod pump controllers were assembled and installed on oilwells in several areas of Central and Western United States. Data was analyzed on these wells and forwarded to the participating oil companies. Cost savings on each individual oil well participatingmore » in the OPC testing vary considerably, savings on some situations have been outstanding. In situations where the pump efficiency was determined to be low, the cost savings have been considerable. Cost savings due to preventive maintenance are also present, but are difficult to pin point an exact dollar amount at the present time. A break out of actual cost data obtained on some of the oilwells controlled and monitored with the oilwell power controller.« less
Investigation of lunar base thermal control system options
NASA Technical Reports Server (NTRS)
Ewart, Michael K.
1993-01-01
Long duration human exploration missions to the Moon will require active thermal control systems which have not previously been used in space. The two technologies which are most promising for long term lunar base thermal control are heat pumps and radiator shades. Recent trade-off studies at the Johnson Space Center have focused development efforts on the most promising heat pump and radiator shade technologies. Since these technologies are in the early stages of development and many parameters used in the study are not well defined, a parametric study was done to test the sensitivity to each assumption. The primary comparison factor in these studies was the total mass system, with power requirements included in the form of a mass penalty for power. Heat pump technologies considered were thermally driven heat pumps such as metal hydride, complex compound, absorption and zeolite. Also considered were electrically driven Stirling and vapor compression heat pumps. Radiator shade concepts considered included step shaped, V-shaped and parabolic (or catenary) shades and ground covers. A further trade study compared the masses of heat pump and radiator shade systems.
Refractory Coronary Artery Spasm after Minimally Invasive Direct Coronary Artery Bypass Grafting
Ju, Min Ho; Kim, Joon-Bum; Kim, Hee Jung
2011-01-01
Postoperative coronary arterial spasm is a rare but potentially fatal complication. A 51-year-old male patient with a history of a reactive ergonovine stress test coronary angiogram developed refractory coronary artery spasm after undergoing minimally invasive direct coronary artery bypass grafting of the left anterior descending coronary artery. The patient was successfully managed with rapid implementation of intra-aortic balloon-pump counter pulsation and extracorporeal membrane oxygenation. PMID:22263171
Kim, Ki-Bong; Hwang, Ho Young; Hahn, Seokyung; Kim, Jun Sung; Oh, Se Jin
2014-09-01
The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial was designed to evaluate the noninferiority of the saphenous vein (SV) compared with the right internal thoracic artery ([R]ITA) used as a Y-composite graft. A total of 224 patients who had undergone off-pump revascularization for multivessel coronary artery disease using the SV or RITA as a Y-composite graft based on the in situ left ITA were assigned randomly to the SV Y-composite graft (SV group, n = 112) or free RITA Y-composite graft (RITA group, n = 112). The primary endpoint was the 1-year angiographic patency rate of the second limb conduits (SV or RITA). Postoperative 1-year coronary angiograms were performed in 215 patients (SV group, 108; RITA group, 107). The overall graft patency rate was 97.4% (745 of 765) at 1 year (97.9% in the SV group vs 96.9% in the RITA group, P = .362). The primary endpoint of the study, the 1-year patency rate of the SV composite grafts, was 97.1% (238 of 245) and was noninferior to that of the RITA composite grafts (97.1% [198 of 204]) with a 95% lower confidence limit of -2.6% (P < .001 for noninferiority). The graft qualities, evaluated using the FitzGibbon patency grades, were also similar between the 2 groups (P = .948). No statistically significant differences were found in the overall survival rates between the 2 groups at 1 and 4 years (P = .998). Also, no statistically significant differences were found between the 2 groups in the freedom from major adverse cardiac and cerebrovascular event rates at 1 and 4 years (P = .597). The SV composite grafts were noninferior to the RITA composite grafts in terms of the 1-year angiographic patency rates. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Barszcz, Karolina; Kupczyńska, Marta; Klećkowska-Nawrot, Joanna; Janeczek, Maciej; Goździewska-Harłajczuk, Karolina; Dzierzęcka, Małgorzata; Janczyk, Paweł
2017-01-01
The aim of this study was to measure the area of the coronary ostia, assess their localization in the coronary sinuses and to determine the morphology of the stem of the left and right coronary arteries in the domestic shorthair cat. The study was conducted on 100 hearts of domestic shorthair cats of both sexes, aged 2–18 years, with an average body weight of 4.05 kg. A morphometric analysis of the coronary ostia was carried out on 52 hearts. The remaining 48 hearts were injected with a casting material in order to carry out a morphological assessment of the left and right coronary arteries. In all the studied animals, the surface of the left coronary artery ostium was larger than the surface of the right coronary artery ostium. There were four types of the left main coronary artery: type I (23 animals, 49%)–double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch, which in turn gave off the septal branch), type II (12 animals, 26%)–double-branched left main stem (giving off the left circumflex branch and the interventricular paraconal branch without the septal branch), type III (11 animals, 23%)–triple-branched left main stem (giving off the left circumflex branch, interventricular branch and the septal branch, type IV (1 animal, 2%)–double-branched left main stem (giving off the interventricular paraconal branch and the left circumflex branch, which in turn gave off the septal branch). The left coronary artery ostium is greater than the right one. There is considerable diversity in the branches of proximal segment of the left coronary artery, while the right coronary artery is more conservative. These results can be useful in defining the optimal strategies in the endovascular procedures involving the coronary arteries or the aortic valve in the domestic shorthair cat. PMID:29020103
Choroidal microcirculation in patients with rotary cardiac assist device.
Polska, Elzbieta; Schima, Heinrich; Wieselthaler, Georg; Schmetterer, Leopold
2007-06-01
In recent years, fully implanted rotary blood pumps have been used for long-term cardiac assist in patients with end-stage heart failure. With these pumps, the pulsatility of arterial blood flow and arterial pressure pulse is considerably reduced. Effects on end-organ perfusion, particularly microcirculation, have been assessed. The ocular choroid offers a unique opportunity to study the pulsatile component of blood flow by measurement of fundus pulsation amplitude (FPA) as well as the microcirculation by laser Doppler flowmetry. Both techniques were applied in three male patients with rotary pumps (MicroMed DeBakey VAD), in whom pump velocity was adjusted to four levels of flow between individual minimal need and maximal support. In addition, blood flow velocities in the ophthalmic artery (peak, end-diastolic and mean flow velocity--PSV, EDV and MFV, respectively) were measured using color Doppler imaging. Systolic blood pressure increased by 6 to 22 mm Hg with increasing support. At maximal support FPA was reduced by -60% to -52% as compared with minimal pump support. Blood flow in the choroidal microvasculature, however, did not show relevant changes. A reduction in PSV (-31%, range -47% to -21%) and a pronounced rise in EDV (+93%, range +28% to +147%) was observed, whereas MFV was independent of pump flow. Our data indicate that mean choroidal blood flow is maintained when pump support is varied within therapeutic values, whereas the ratio of pulsatile to non-pulsatile choroidal flow changes. This study shows that, in patients with ventricular assist devices, a normal perfusion rate in the ocular microcirculation is maintained over a wide range of support conditions.
Yan, X G; Lu, Z J; Zheng, J C; Zhang, W W; Lu, G P; Jia, B
2016-07-01
To summarize the experience in applying a technique of inserting a cannula through right internal jugular vein and common carotid artery to build extracorporeal membrane oxygenation (ECMO) for critically ill children. The data of critically ill patients received ECMO support through right internal jugular vein and common carotid artery between December 2011 and December 2015 from Children's Hospital of Fudan University were analyzed retrospectively.The data included diagnosis, age, body weight, time of cannula and ECMO running, complication and prognosis. In total 28 patients received ECMO support, 3 patients of post-cardiac surgery with transthoracic cannula were excluded.Twenty-five patients inserted cannula through neck vessels were enrolled, 15 boys and 10 girls, the median age was 1.8 years (range, 1 d-13 years), the median weight was 12.0 (2.8-50.0) kg.All the cannula sites were right internal jugular vein and right common carotid artery, before cannula use 5 patients had been inserted central vein tube and 3 patients with blood filter tube in right internal jugular vein, in one case cannula was applied during cardiopulmonary resuscitation.V-A ECMO had been built for all the cases successfully, the median operation time was (45±26) min.The pump flow was 80-150 ml/(kg·min), the median duration of ECMO support was 153(14-567) h. Sixteen (64%) patients weaned off ECMO successfully, 15(60%) survived to hospital discharge.About the complication of cannula, six patients developed cannula site bleeding, and two patients required re-fixation of cannula, one patient's external jugular vein had been hurt and sutured for bleeding. Application of right jugular vessels to build ECMO is easy and safe for treating the sick children. The skill should be proficient to assure ECMO run and reduce the complications.
Cheng, Yanping; Yi, Geng-Hua; Annest, Lon S; Van Bladel, Kevin; Brown, Ryan; Wechsler, Andrew; Shibuya, Masahiko; Conditt, Gerard B; Peppas, Athanasios; Kaluza, Greg L; Granada, Juan F
2015-04-01
To test the feasibility of a thoracoscopically assisted, off-pump, transcatheter ventricular reconstruction (TCVR) approach in an ovine model of left ventricular (LV) anteroapical aneurysm. Myocardial infarction (MI) was induced by coil occlusion of the middle left anterior descending artery and diagonals. Two months after MI creation, TCVR was performed via a minimal thoracotomy in eight sheep. Under endoscopic and fluoroscopic guidance, trans-interventricular septal puncture was performed from the LV epicardial scar. A guidewire was externalised via a snare placed in the right ventricle from the external jugular vein. An internal anchor was inserted over the wire and positioned on the right ventricular septum and an external anchor was deployed on the LV anterior epicardium. Serial pairs of anchors were placed and plicated together to exclude the scar completely. Immediately after TCVR, echocardiography showed LV end-systolic volume decreased from pre-procedure 58.8±16.6 ml to 25.1±7.6 ml (p<0.01) and the ejection fraction increased from 32.0±7.3% to 52.0±7.5% (p<0.01). LV twist significantly improved (3.83±2.21 vs. pre-procedure -0.41±0.94, p=0.01) and the global peak-systolic longitudinal strain increased from -5.64% to -10.77% (p<0.05). TCVR using minimally invasive access techniques on the off-pump beating heart is feasible and resulted in significant improvement in LV performance.
Shah, Shaneel; Benedetto, Umberto; Caputo, Massimo; Angelini, Gianni D; Vohra, Hunaid A
2018-06-22
Existing evidence comparing the outcomes of coronary artery bypass graft (CABG) surgery versus percutaneous coronary intervention (PCI) in patients with poor left ventricular function (LVF) is sparse and flawed. This is largely due to patients with poor LVF being underrepresented in major research trials and the outdated nature of some studies that do not consider drug-eluting stent PCI. Following strict inclusion criteria, 717 patients who underwent revascularization by CABG or PCI between 2002 and 2015 were enrolled. All patients had poor LVF (defined by ejection fraction <30%). By employing a propensity score analysis, 134 suitable matches (67 CABG and 67 PCI) were identified. Several outcomes were evaluated, in the matched population, using data extracted from national registry databases. CABG patients required a longer length of hospital stay post-revascularization compared to PCI in the propensity-matched population, 7 days (lower-upper quartile; 6-12) and 2 days (lower-upper quartile; 1-6), respectively (Mood's median test, P = 0.001). Stratified Cox-regression proportional-hazards analysis of the propensity-matched population found that PCI patients experienced a higher adjusted 8-year mortality rate (hazard ratio 3.291, 95% confidence interval 1.776-6.101; P < 0.001). This trend was consistent amongst urgent cases of revascularization: patients with 3 or more vessels with coronary artery disease and patients where complete revascularization was achieved. Although sub-analyses found no difference between survival distributions of on-pump versus off-pump CABG (log-rank P = 0.726), both modes of CABG were superior to PCI (stratified log-rank P = 0.002). Despite a longer length of hospital stay, patients with impaired LVF requiring intervention for coronary artery disease experienced a greater post-procedural survival benefit if they received CABG compared to PCI. We have demonstrated this at 30 days, 90 days, 1 year, 3 years, 5 years and 8 years following revascularization. At present, CABG remains a superior revascularization modality to PCI in patients with poor LVF.
Meinhardt, J P; Ashton, B A; Annich, G M; Quintel, M; Hirschl, R B
2003-05-30
To evaluate the influence of pump system and flow pattern on expiratory airway collapse (EAC) in total perfluorocarbon ventilation. - Prospective, controlled, randomized animal trial for determination of (1) post-mortem changes by repeated expiration procedures (EP) with a constant flow piston pump (PP) before and after sacrifice (n = 8 rabbits), (2) differences between pump systems by subjecting animals to both PP and roller pump (RP) circuits for expiration (n = 16 rabbits). EP were performed using a servo-controlled shut-off at airway pressures < 25 cm H subset 2O randomly with either pump at different flows. - Expired volumes before and after sacrifice were not significantly different. PP and RP revealed identical mean flows, while significantly more liquid was drained using PP (p<0.05). Increasing differences towards higher flow rates indicated profound flow pulsatility in RP. - (1) post-mortem changes in expired volumes are not significant, (2) EAC is related to flow rate and pump system; (3) relationship between expiratory flow rate and drainable liquid volume is linear inverse; (4) PP provides higher drainage than RP. - Expiratory airway collapse is related to flow rate and pump system, post mortem changes in expirable volumes are not significant. Relationship between expiratory flow rate and drainable liquid volume is linear inverse, piston pump expiration provides higher drainage volumes than roller pump expiration.
Shammas, Nicolas W
2017-06-01
Distal embolization is a common occurrence with peripheral arterial interventions and is more frequent with the use of atherectomy devices. We report the first case of JetStream atherectomy (Boston Scientific, Maple Grove, MN) with the use of the novel WIRION embolic protection system filter. The procedure was performed successfully with no distal embolizations beyond the filter and with no complications in the delivery or retrieval of the filter. The pros and cons of the off label use of this filter with JetStream atherectomy are discussed.
Hemodynamic energy generated by a combined centrifugal pump with an intra-aortic balloon pump.
Lim, Choon Hak; Son, Ho Sung; Fang, Yung Hu; Lee, Jung Joo; Baik, Kwang Je; Kim, Kyung Hyun; Kim, Bum Soo; Lee, Hye Won; Sun, Kyung
2006-01-01
We examined the pulsatility generated by an intra-aortic balloon pump/centrifugal pump (IABP/CP) combination in terms of energy equivalent pressure (EEP) and surplus hemodynamic energy (SHE). In five cardiac-arrested pigs, the outflow cannula of the CP was inserted into the ascending aorta, the inflow cannula in the right atrium. A 30-ml IABP was subsequently placed in the descending aorta. Extracorporeal circulation was maintained for 30 minutes using a pump flow of 75 ml/kg per minute by CP alone or by IABP/CP with pressure and flow measured in the right internal carotid artery. The IABP/CP combination converted the flow to pulsatile and increased pulse pressure significantly from 9.1 +/- 1.3 mm Hg to 54.9 +/- 6.1 mm Hg (p = 0.012). It also significantly increased the percent change from mean arterial pressure to EEP from 0.2 +/- 0.3% to 23.3 +/- 6.1% (p = 0.012) and SHE from 133.2 +/- 234.5 erg/cm to 20,219.8 +/- 5842.7 erg/cm3 (p = 0.012). However, no statistical difference was observed between CP and IABP/CP in terms of mean carotid artery pressure (p = NS). In a cardiac-arrested animal model, pulsatility generated by a IABP/CP combination may be effective in terms of energy equivalent pressure and surplus hemodynamic energy.
Experiments On Flow In A Coronary Artery
NASA Technical Reports Server (NTRS)
Back, Lloyd H.; Kwack, Eug-Yon; Liem, Timothy K.; Crawford, Donald W.
1993-01-01
Report describes experiments on simulated flow of blood in atherosclerotic human coronary artery. Experiments performed on polyurethane cast made from S-shaped coronary artery of cadaver. Sucrose solution with viscosity of blood pumped through cast at physiologically realistic rates, and flow made pulsatile by mechanism alternately compressing and releasing elastic tube just upstream of cast.
Brain function monitoring during off-pump cardiac surgery: a case report
Zanatta, Paolo; Bosco, Enrico; Di Pasquale, Piero; Nivedita, Agarwal; Valfrè, Carlo; Sorbara, Carlo
2008-01-01
Background Early postoperative stroke is an adverse syndrome after coronary bypass surgery. This report focuses on overcoming of cerebral ischemia as a result of haemodynamic instability during heart enucleation in off-pump procedure. Case presentation A 67 year old male patient, Caucasian race, with a body mass index of 28, had a recent non-Q posterolateral myocardial infarction one month before and recurrent instable angina. His past history includes an uncontrolled hypertension, dyslipidemia, insulin dependent diabetes mellitus, epiaortic vessel stenosis. The patient was scheduled for an off-pump procedure and monitored with bilateral somatosensory evoked potentials, whose alteration signalled the decrement of the cardiac index during operation. The somatosensory evoked potentials appeared when the blood pressure was increased with a pharmacological treatment. Conclusion During the off-pump coronary bypass surgery, a lower cardiac index, predisposes patients, with multiple stroke risk factors, to a reduction of the cerebral blood flow. Intraoperative somatosensory evoked potentials monitoring provides informations about the functional status of somatosensory cortex to reverse effects of brain ischemia. PMID:18706094
Coronary anatomy in children with bicuspid aortic valves and associated congenital heart disease.
Koenraadt, Wilke M C; Bartelings, Margot M; Bökenkamp, Regina; Gittenberger-de Groot, Adriana C; DeRuiter, Marco C; Schalij, Martin J; Jongbloed, Monique Rm
2018-03-01
In patients with bicuspid aortic valve (BAV), coronary anatomy is variable. High take-off coronary arteries have been described, but data are scarce, especially when associated with complex congenital heart disease (CHD). The purpose of this study was to describe coronary patterns in these patients. In 84 postmortem heart specimens with BAV and associated CHD, position and height of the coronary ostia were studied and related to BAV morphology. High take-off right (RCA) and left coronary arteries (LCA) were observed in 23% and 37% of hearts, respectively, most frequently in hearts with hypoplastic left ventricle (HLV) and outflow tract anomalies. In HLV, high take-off was observed in 18/40 (45%) more frequently of LCA (n=14) than RCA (n=6). In hearts with aortic hypoplasia, 8/13 (62%) had high take-off LCA and 6/13 (46%) high take-off RCA. High take-off was seen 19 times in 22 specimens with perimembranous ventricular septal defect (RCA 8, LCA 11). High take-off was associated with type 1A BAV (raphe between right and left coronary leaflets), more outspoken for the RCA. Separate ostia of left anterior descending coronary artery and left circumflex coronary artery were seen in four hearts (5%), not related to specific BAV morphology. High take-off coronary arteries, especially the LCA, occur more frequently in BAV with associated CHD than reported in normal hearts and isolated BAV. Outflow tract defects and HLV are associated with type 1A BAV and high take-off coronary arteries. Although it is unclear whether these findings in infants with detrimental outcome can be related to surviving adults, clinical awareness of variations in coronary anatomy is warranted. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Off-pump repair of a post-infarct ventricular septal defect: the 'Hamburger procedure'
Barker, Thomas A; Ng, Alexander; Morgan, Ian S
2006-01-01
We report a novel off-pump technique for the surgical closure of post-infarct ventricular septal defects (VSDs). The case report describes the peri-operative management of a 76 year old lady who underwent the 'Hamburger procedure' for closure of her apical VSD. Refractory cardiogenic shock meant that traditional patch repairs requiring cardiopulmonary bypass would be poorly tolerated. We show that echocardiography guided off-pump posterior-anterior septal plication is a safe, effective method for closing post-infarct VSDs in unstable patients. More experience is required to ascertain whether this technique will become an accepted alternative to patch repairs. PMID:16722552
Right pleuropericardial release: a useful technique in off-pump coronary surgery.
Velissaris, Theodore; Stuklis, Robert G; Hett, David A; Ohri, Sunil K
2003-06-01
We describe the use of right pleurotomy combined with right pericardial release during off-pump coronary surgery. The maneuver releases the compression exerted on the right cardiac chambers during cardiac verticalization and improves hemodynamic stability during exposure of the posterior or lateral coronary vessels.
Chang, Kyung-ho; Bougaki, Masahiko; Kubota, Ryou; Tsubaki, Kumiko; Matsuo, Hideki; Hanaoka, Kazuo
2003-04-01
Although there is growing evidence to suggest that magnesium supplementation to patients undergoing cardiac surgery is beneficial, the way to administer magnesium is not established. Moreover in Japan St Thomas' cardioplegic solution, containing a high level of magnesium is widely used and the effect of such magnesium-rich cardioplegic solutions on blood magnesium concentration has not been well defined. We measured ionized magnesium concentrations (iMg) during cardiac surgery employing St Thomas' solution. Patients were divided into four groups. Group 1 patients were adults and group 2 were children, both of whom received St. Thomas' solution. Group 3 patients underwent cardiopulmonary bypass but did not receive any cardioplegic solution. Group 4 patients underwent off-pump coronary artery bypass grafting. In cardioplegia group (group 1 and 2) iMg was higher than the normal reference range at periods of rewarming, immediately postbypass, and at the end of the operation. iMg at immediately postbypass was related to the total amount of cardioplegic solution. In non-cardioplegia group (group 3 and 4) progressive decrease of iMg was observed throughout the operation. Because magnesium in cardioplegic solutions has substantial effect on perioperative iMg, it is crucial to measure iMg to avoid overdose of magnesium when magnesium-rich cardioplegic solutions are employed.
Beckmann, Andreas; Funkat, Anne-Katrin; Lewandowski, Jana; Frie, Michael; Ernst, Markus; Hekmat, Khosro; Schiller, Wolfgang; Gummert, Jan F; Harringer, Wolfgang
2017-10-01
Based on a long-standing voluntary registry founded by the German Society for Thoracic and Cardiovascular Surgery (GSTCVS), well-defined data of all cardiac, thoracic, and vascular surgery procedures performed in 78 German heart surgery departments during the year 2016 are analyzed. In 2016, a total of 103,128 heart surgery procedures (implantable defibrillator, pacemaker, and extracardiac procedures excluded) were submitted to the registry. Approximately 15.7% of the patients were at least 80 years of age, resulting in an increase of 0.9% compared with the data of 2015. For 37,614 isolated coronary artery bypass grafting procedures (relationship on-/off-pump 4.4:1), an unadjusted in-hospital mortality of 2.9% was observed. Concerning the 33,451 isolated heart valve procedures (including 11,701 catheter-based procedures), the unadjusted in-hospital mortality was 4.3%. This annual updated registry of the GSTCVS represents voluntary public reporting by accumulating actual information for nearly all heart surgical procedures in Germany, describes advancements in heart medicine, and is a basis for internal and external quality assurances for all participants. In addition, the registry demonstrates that the provision of cardiac surgery in Germany is appropriate and patients are treated nationwide at all times.
Computerized tomography-based anatomic description of the porcine liver.
Bekheit, Mohamed; Bucur, Petru O; Wartenberg, Mylene; Vibert, Eric
2017-04-01
The knowledge of the anatomic features is imperative for successful modeling of the different surgical situations. This study aims to describe the anatomic features of the porcine using computerized tomography (CT) scan. Thirty large, white, female pigs were included in this study. The CT image acquisition was performed in four-phase contrast study. Subsequently, analysis of the images was performed using syngo.via software (Siemens) to subtract mainly the hepatic artery and its branches. Analysis of the portal and hepatic veins division pattern was performed using the Myrian XP-Liver 1.14.1 software (Intrasense). The mean total liver volume was 915 ± 159 mL. The largest sector in the liver was the right medial one representing around 28 ± 5.7% of the total liver volume. Next in order is the right lateral sector constituting around 24 ± 5%. Its volume is very close to the volume of the left medial sector, which represents around 22 ± 4.7% of the total liver volume. The caudate lobe represents around 8 ± 2% of the total liver volume.The portal vein did not show distinct right and left divisions rather than consecutive branches that come off the main trunk. The hepatic artery frequently trifurcates into left trunk that gives off the right gastric artery and the artery to the left lateral sector, the middle hepatic artery that supplies both the right and the left medial sectors and the right hepatic artery trunk that divides to give anterior branch to the right lateral lobe, branch to the right medial lobe, and at least a branch to the caudate lobe. Frequently, there is a posterior branch that crosses behind the portal vein to the right lateral lobe. The suprahepatic veins join the inferior vena cava in three distinct openings. There are communications between the suprahepatic veins that drain the adjacent sectors. The vein from the right lateral and the right medial sectors drains into a common trunk. The vein from the left lateral and from the left medial sectors drains into a common trunk. A separate opening is usually encountered draining the right medial sector. The caudate lobe drains separately into inferior vena cava caudal to the other veins. Knowledge of the anatomic features of the porcine liver is crucial to the performance of a successful surgical procedure. We herein describe the CT-depicted anatomic features of the porcine liver. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Malyutin, A. A.
2007-03-01
Modes of a laser with plano-spherical degenerate and nondegenerate resonators are calculated upon diode pumping producing the Gaussian gain distribution in the active medium. Axially symmetric and off-axis pumpings are considered. It is shown that in the first case the lowest Hermite-Gaussian mode is excited with the largest weight both in the degenerate and nondegenerate resonator if the pump level is sufficiently high or the characteristic size wg of the amplifying region greatly exceeds the mode radius w0. The high-order Ince-Gaussian modes are excited upon weak off-axis pumping in the nondegenerate resonator both in the absence and presence of the symmetry of the gain distribution with respect to the resonator axis. It is found that when the level of off-axis symmetric pumping of the resonator is high enough, modes with the parameters of the TEM00 mode periodically propagating over a closed path in the resonator can exist. The explanation of this effect is given.
Presentation of a quality management program in off-pump coronary bypass surgery.
Bougioukakis, Petros; Kluegl, Stefan J; Babin-Ebell, Joerg; Tagarakis, Giorgios I; Mandewirth, Martin; Zacher, Michael; Diegeler, Anno
2014-01-01
To increase the number of off-pump coronary procedures at our institution, a new surgical team was formed. The first 3 years of "learning period" were accompanied by a quality management program aimed to control and adjust the surgical process and to ensure the safety and quality of the procedure. All patients were operated on by the same surgeon between January 2004 and December 2006; all procedures were performed under the following quality management protocol. First, a flow chart regulated surgical and anesthetic details. Second, an online file, named "disturbance file," was used to report work flow interruption, disturbance, and intraoperative events, that is, myocardial ischemia, hypotension, conversion to cardiopulmonary bypass, and any violation of the protocol. Each event was coded with 1 point and added to a score (the higher the score is, the greater the disturbance). Outcome parameters known as major events-major cardiac and cerebral events: mortality within 30 days/myocardial infarction confirmed by electrocardiogram or significantly high levels of total creatine kinase-myocardial muscle creatine kinase/reintervention within 30 days/stroke--and new-onset dialysis were also measured. Success was defined as freedom from any of those events and depicted in a cumulative sum control (CUSUM) chart. Outcome data and CUSUM were correlated with the intraoperative Disturbance Index. In total, 490 off-pump coronary bypass operations were performed by the named surgeon during the study period. The 30-day mortality was reduced from 4.0% to 1.9%. Disturbance Index score of greater than 1 declined from 41.6% to 23.3%. All major cardiac and cerebral events declined. The CUSUM chart showed two critical periods during the learning period, which made an adjustment of the protocol necessary. Quality management control is efficient in improving the postoperative results of a surgical procedure. A learning period is of cardinal importance for any new team wishing to engage in a novel surgical technique.
NASA Astrophysics Data System (ADS)
van Heeringen, Klaas-Jan; van Nooijen, Ronald; Kooij, Kees; Postma, Bokke
2016-04-01
The Garmerwolde waste water treatment plant (WWTP) in the Groningen area of the Netherlands, receives waste water from a large area. That waste water is collected from many sewer systems and transported to the WWTP through pressurized pipes. The supply of waste water to the WWTP is relatively low and very irregular during dry-weather conditions, resulting in a random pattern of flows. This irregularity is the effect of the local control of the pumps, where the pumps are individually operated as an on/off control based on the water levels in the connected sewer system. The influent may change from zero to high values in a few minutes. The treatment processes at the WWTP are negatively influenced by this irregularity, which ends in high costs for energy and use of chemicals. The ControlNEXT central control system is used to control the 5 largest pump stations, such that the total inflow at the WWTP becomes much smoother. This results in a reduction of operational costs of about 10%. The control algorithm determines whether the actual condition is dry or wet, based on real-time radar precipitation images and the rainfall forecast product HiRLAM. All actual data is also collected and validated, like water levels, pump operations and pump availability. This data management is done using Delft-FEWS. If the situation is identified as "wet", the sewer systems are emptied as far as possible to create maximum storage. If the situation is "dry" (and of course there is a dead band between dry and wet), the pumps are operated such that the total inflow into the WWTP is smoothed. This is done with a Greedy algorithm, developed by Delft University of Technology. The algorithm makes a plan for the next 24 hours (as the daily inflow has a typical daily pattern) and generally stores some water volume in the sewer systems during the day to be able to continue operations during the night. The pumps are controlled with a time step of 5 minutes, where ControlNEXT manages the communication of pump operation setpoints to the SCADA system. In case of failing communication, backup procedures are programmed in the PLC of the pump stations. In that case the old on/off operation based on local water levels will be used. The system has been operational since January 2016 and has been monitored since then. In addition to monitoring the positive effect on the inflow at the WWTP, an important issue is the possible sedimentation in the sewer systems. This will be monitored too.
Analysis of off-grid hybrid wind turbine/solar PV water pumping systems
USDA-ARS?s Scientific Manuscript database
While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic , wind-electric, diesel powered), very few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) a...
Intra-Aortic Balloon Pump Malposition Reduces Visceral Artery Perfusion in an Acute Animal Model.
Vondran, Maximilian; Rastan, Ardawan J; Tillmann, Eugen; Seeburger, Jörg; Schröter, Thomas; Dhein, Stefan; Bakhtiary, Farhad; Mohr, Friedrich-Wilhelm
2016-04-01
Visceral artery perfusion can be potentially affected by intra-aortic balloon pump (IABP) catheters. We utilized an animal model to quantify the acute impact of a low balloon position on mesenteric artery perfusion. In six pigs (78 ± 7 kg), a 30-cc IABP was placed in the descending aorta in a transfemoral procedure. The celiac artery (CA) and the cranial mesenteric artery (CMA) were surgically dissected. Transit time blood flow was measured for (i) baseline, (ii) 1:1 augmentation with the balloon proximal to the visceral arteries, and (iii) 1:1 augmentation with the balloon covering the visceral arteries. Blood flow in the CMA and CA was reduced by 17 and 24%, respectively, when the balloon compromised visceral arteries compared with a position above the visceral arteries (flow in mL/min: CMA: (i) 1281 ± 512, (ii) 1389 ± 287, (iii) 1064 ± 276, P < 0.05 for 3 vs. 1 and 3 vs. 2; CA: (i) 885 ± 370, (ii) 819 ± 297, (iii) 673 ± 315; P < 0.05 for 3 vs. 1). The covering of visceral arteries by an IABP balloon causes a significant reduction of visceral artery perfusion; thus, the positioning of this device during implantation is critical for obtaining a satisfactory outcome. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
New concepts and new design of permanent maglev rotary artificial heart blood pumps.
Qian, K X; Zeng, P; Ru, W M; Yuan, H Y
2006-05-01
According to tradition, permanent maglev cannot achieve stable equilibrium. The authors have developed, to the contrary, two stable permanent maglev impeller blood pumps. The first pump is an axially driven uni-ventricular assist pump, in which the rotor with impeller is radially supported by two passive magnetic bearings, but has one point contact with the stator axially at standstill. As the pump raises its rotating speed, the increasing hydrodynamic force of fluid acting on the impeller will make the rotor taking off from contacting point and disaffiliate from the stator. Then the rotor becomes fully suspended. The second pump is a radially driven bi-ventricular assist pump, i.e., an impeller total artificial heart. Its rotor with two impellers on both ends is supported by two passive magnetic bearings, which counteract the attractive force between rotor magnets and stator coil iron core. The rotor is affiliated to the stator radially at standstill and becomes levitated during rotation. Therefore, the rotor keeps concentric with stator during rotation but eccentric at standstill, as is confirmed by rotor position detection with Honeywell sensors. It concludes that the permanent maglev needs action of a non-magnetic force to achieve stability but a rotating magnetic levitator with high speed and large inertia can maintain its stability merely with passive magnetic bearings.
Uehara, Mayuko; Takagi, Nobuyuki; Muraki, Satoshi; Yanase, Yosuke; Tabuchi, Masaki; Tachibana, Kazutoshi; Miyaki, Yasuko; Ito, Toshiro; Higami, Tetsuya
2015-12-01
Transit-time flow measurement (TTFM) parameters such as mean graft flow (MGF, ml/min), pulsatility index (PI) and diastolic filling (DF, %) have been extensively researched for internal mammary arterial or saphenous vein grafts. In our experience of using the right gastroepiploic arterial (GEA) graft for right coronary artery (RCA) grafting, we observed unique GEA graft flow waveforms. We analysed the GEA graft flow waveforms for their effectiveness in determining GEA graft patency by power spectral analysis. Forty-five patients underwent off-pump coronary artery bypass using the GEA graft for RCA grafting individually. The means of intraoperative MGF, PI and DF were compared between patent and non-patent grafts, postoperatively. Furthermore, the GEA flow data were output and analysed using power spectral analysis. Forty grafts were 'patent' and five were 'non-patent'. There were no significant differences in the mean TTFM parameters between the patent and non-patent grafts (MGF: 22 vs 8 ml/min, respectively, P = 0.068; PI: 3.5 vs 6.5, respectively, P = 0.155; DF: 63 vs 53%, respectively, P = 0.237). Results of the power spectral analysis presented clear differences; the power spectral density (PSD) of patent grafts presented high peaks at frequency levels of 1, 2 and 3 Hz, and the non-patent graft PSD presented high peaks that were not limited to these frequencies. The PSD had a sensitivity and specificity of 80 and 87.5%, respectively. Power spectral analysis of the GEA graft flow is useful to distinguish between non-patent and patent grafts intraoperatively. This should be used as a fourth parameter along with MGF, PI and DF. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Numerical Simulation of Tubular Pumping Systems with Different Regulation Methods
NASA Astrophysics Data System (ADS)
Zhu, Honggeng; Zhang, Rentian; Deng, Dongsheng; Feng, Xusong; Yao, Linbi
2010-06-01
Since the flow in tubular pumping systems is basically along axial direction and passes symmetrically through the impeller, most satisfying the basic hypotheses in the design of impeller and having higher pumping system efficiency in comparison with vertical pumping system, they are being widely applied to low-head pumping engineering. In a pumping station, the fluctuation of water levels in the sump and discharge pool is most common and at most time the pumping system runs under off-design conditions. Hence, the operation of pump has to be flexibly regulated to meet the needs of flow rates, and the selection of regulation method is as important as that of pump to reduce operation cost and achieve economic operation. In this paper, the three dimensional time-averaged Navier-Stokes equations are closed by RNG κ-ɛ turbulent model, and two tubular pumping systems with different regulation methods, equipped with the same pump model but with different designed system structures, are numerically simulated respectively to predict the pumping system performances and analyze the influence of regulation device and help designers make final decision in the selection of design schemes. The computed results indicate that the pumping system with blade-adjusting device needs longer suction box, and the increased hydraulic loss will lower the pumping system efficiency in the order of 1.5%. The pumping system with permanent magnet motor, by means of variable speed regulation, obtains higher system efficiency partly for shorter suction box and partly for different structure design. Nowadays, the varied speed regulation is realized by varied frequency device, the energy consumption of which is about 3˜4% of output power of the motor. Hence, when the efficiency of variable frequency device is considered, the total pumping system efficiency will probably be lower.
Levin, Ricardo; Degrange, Marcela; Del Mazo, Carlos; Tanus, Eduardo; Porcile, Rafael
2012-01-01
BACKGROUND: The calcium sensitizer levosimendan has been used in cardiac surgery for the treatment of postoperative low cardiac output syndrome (LCOS) and difficult weaning from cardiopulmonary bypass (CPB). OBJECTIVES: To evaluate the effects of preoperative treatment with levosimendan on 30-day mortality, the risk of developing LCOS and the requirement for inotropes, vasopressors and intra-aortic balloon pumps in patients with severe left ventricular dysfunction. METHODS: Patient with severe left ventricular dysfunction and an ejection fraction <25% undergoing coronary artery bypass grafting with CPB were admitted 24 h before surgery and were randomly assigned to receive levosimendan (loading dose 10 μg/kg followed by a 23 h continuous infusion of 0.1μg/kg/min) or a placebo. RESULTS: From December 1, 2002 to June 1, 2008, a total of 252 patients were enrolled (127 in the levosimendan group and 125 in the control group). Individuals treated with levosimendan exhibited a lower incidence of complicated weaning from CPB (2.4% versus 9.6%; P<0.05), decreased mortality (3.9% versus 12.8%; P<0.05) and a lower incidence of LCOS (7.1% versus 20.8%; P<0.05) compared with the control group. The levosimendan group also had a lower requirement for inotropes (7.9% versus 58.4%; P<0.05), vasopressors (14.2% versus 45.6%; P<0.05) and intra-aortic balloon pumps (6.3% versus 30.4%; P<0.05). CONCLUSION: Patients with severe left ventricle dysfunction (ejection fraction <25%) undergoing coronary artery bypass grafting with CPB who were pretreated with levosimendan exhibited lower mortality, a decreased risk for developing LCOS and a reduced requirement for inotropes, vasopressors and intra-aortic balloon pumps. Studies with a larger number of patients are required to confirm whether these findings represent a new strategy to reduce the operative risk in this high-risk patient population. PMID:23620700
Fluid dynamics of heart assist device
NASA Technical Reports Server (NTRS)
Jones, R. T.
1976-01-01
Certain hemodynamic phenomena that arise in connection with the use of artificial blood pumping devices are reviewed. Among these are: (1) Flows produced by collapsing bulbs; (2) the impedance presented by the aorta; (3) limiting velocities and instability of flow in elastic vessels; (4) effectiveness of valveless arterio-arterial pumps, and (5) wave reflection phenomena and instabilities associated with the intra-aortic balloon pump.
Design of a high-pressure circulating pump for viscous liquids.
Seifried, Bernhard; Temelli, Feral
2009-07-01
The design of a reciprocating dual action piston pump capable of circulating viscous fluids at pressures of up to 34 MPa (5000 psi) and temperatures up to 80 degrees C is described. The piston of this pump is driven by a pair of solenoids energized alternatively by a 12 V direct current power supply controlled by an electronic controller facilitating continuously adjustable flow rates. The body of this seal-less pump is constructed using off-the-shelf parts eliminating the need for custom made parts. Both the electronic controller and the pump can be assembled relatively easily. Pump performance has been evaluated at room temperature (22 degrees C) and atmospheric pressure using liquids with low and moderately high viscosities, such as ethanol and corn oil, respectively. At ambient conditions, the pump delivered continuous flow of ethanol and corn oil at a flow rate of up to 170 and 17 cm3/min, respectively. For pumping viscous fluids comparable to corn oil, an optimum reciprocation frequency was ascertained to maximize flow rate. For low viscosity liquids such as ethanol, a linear relationship between the flow rate and reciprocation frequency was determined up to the maximum reciprocation frequency of the pump. Since its fabrication, the pump has been used in our laboratory for circulating triglycerides in contact with supercritical carbon dioxide at pressures of up to 25 MPa (3600 psi) and temperatures up to 70 degrees C on a daily basis for a total of more than 1500 h of operation functioning trouble free.
Blood coagulation using High Intensity Focused Ultrasound (HIFU)
NASA Astrophysics Data System (ADS)
Nguyen, Phuc V.; Oh, Junghwan; Kang, Hyun Wook
2014-03-01
High Intensity Focused Ultrasound (HIFU) technology provides a feasible method of achieving thermal coagulation during surgical procedures. One of the potential clinical benefits of HIFU can induce immediate hemostasis without suturing. The objective of this study was to investigate the efficiency of a HIFU system for blood coagulation on severe vascular injury. ngHIFU treatment was implemented immediately after bleeding in artery. The ultrasound probe was made of piezoelectric material, generating a central frequency of 2.0 MHz as well as an ellipsoidal focal spot of 2 mm in lateral dimension and 10 mm in axial dimension. Acoustic coagulation was employed on a perfused chicken artery model in vitro. A surgical incision (1 to 2 mm long) was made with a scapel on the arterial wall, and heparinized autologous blood was made to leak out from the incision with a syringe pump. A total of 5 femoral artery incisions was treated with the HIFU beam. The intensity of 4500 W/cm2 at the focus was applied for all treatments. Complete hemostasis was achieved in all treatments, along with the treatment times of 25 to 50 seconds. The estimated intraoperative blood loss was from 2 to 5 mL. The proposed HIFU system may provide an effective method for immediate blood coagulation for arteries and veins in clinical applications.
Mold Heating and Cooling Pump Package Operator Interface Controls Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josh A. Salmond
2009-08-07
The modernization of the Mold Heating and Cooling Pump Package Operator Interface (MHC PP OI) consisted of upgrading the antiquated single board computer with a proprietary operating system to off-the-shelf hardware and off-the-shelf software with customizable software options. The pump package is the machine interface between a central heating and cooling system that pumps heat transfer fluid through an injection or compression mold base on a local plastic molding machine. The operator interface provides the intelligent means of controlling this pumping process. Strict temperature control of a mold allows the production of high quality parts with tight tolerances and lowmore » residual stresses. The products fabricated are used on multiple programs.« less
Predictors of new malignant ventricular arrhythmias after coronary surgery: a case-control study.
Ascione, Raimondo; Reeves, Barnaby C; Santo, Kirkpatrick; Khan, Nouman; Angelini, Gianni D
2004-05-05
We sought to investigate the relationship between perioperative factors and the occurrence of ventricular tachycardia (VT) and ventricular fibrillation (VF), as well as the impact of VT/VF on early and late mortality. Both VT and VF are rare but serious complications after coronary artery bypass graft surgery (CABG), and their etiology and implications remain uncertain. Data on 4,411 consecutive patients undergoing CABG (1,154 [25.8%] had off-pump surgery) between April 1996 and September 2001 were extracted from a prospective database and analyzed. Odds ratios (ORs) describing associations between possible risk factors and VT/VF were estimated separately. Factors observed to be significantly associated with VT/VF were further investigated using multivariate logistic regression. Sixty-nine patients suffered VT/VF (1.6%). There were 61 (1.4%) in-hospital/30-day deaths, 15 among patients who had postoperative VT/VF (21.7%). Patient factors independently associated with an increase in the odds of VT/VF included age <65 years, female gender, body mass index <25 kg/m(2), unstable angina, moderate or poor ejection fraction, and the need for inotropes and an intra-aortic balloon pump (OR 1.72 to 4.47, p < 0.05). After adjustment, off-pump surgery was associated with a substantial but nonsignificant protective effect against VT/VF (OR 0.53, 95% confidence interval [CI] 0.25 to 1.13; p = 0.10). Actuarial survival at two years was 98.2% among patients who had VT/VF and who survived to discharge/30 days, compared with 97.0% for the control group (adjusted hazard ratio 0.96 (95% CI 0.40 to 2.31, p = 0.92). The incidence of VT/VF is low in patients undergoing coronary surgery but is associated with high in-hospital mortality. The late survival of the discharged VT/VF patients compares favorably with that of controls.
Coronary artery calcification and large artery stiffness in renal transplant recipients.
Stróżecki, Paweł; Serafin, Zbigniew; Adamowicz, Andrzej; Flisiński, Mariusz; Włodarczyk, Zbigniew; Manitius, Jacek
2015-09-01
Coronary artery calcification (CAC) is an independent predictor of cardiovascular (CV) events in renal transplant recipients (RTR). Carotid-femoral pulse wave velocity (PWV), a non-invasive measure of large artery stiffness, also predicts CV events in RTR. The study investigated the relationship between CAC and PWV in RTR and assessed the performance of PWV measurement in predicting CAC. The study was performed as cross-sectional analysis in 104 RTR. CAC was determined as total calcium score (CS) and calcium mass (CM). Carotid-femoral PWV was also measured. Sensitivity, specificity and receiver operating characteristic (ROC) curve were used to assess the performance of PWV as diagnostic test for presence of CAC. CAC was found in 69% of participants. PWV was higher in RTR with CAC than in RTR without CAC (10.2±2.2 vs. 8.6±15; p<0.001). In univariate analysis CS was significantly correlated with age, duration of hypertension, waist circumference, PWV, hemoglobin concentration, and serum glucose. In multiple linear regression analysis CS was independently associated with age only, but not with PWV. Sensitivity and specificity of PWV>7.6m/s as cut-off for detecting CAC>0 was 0.889 and 0.406, respectively. Sensitivity and specificity of PWV>10.2m/s as cut-off for detecting severe CAC (CS>400) was 0.319 and 0.969, respectively. The study confirmed high prevalence of coronary artery calcification in renal transplant recipients. The study does not support the hypothesis that aortic stiffness is independently associated with coronary artery calcification in RTR. PWV measurement may be useful in excluding severe CAC in RTR. Copyright © 2015 Medical University of Bialystok. Published by Elsevier Urban & Partner Sp. z o.o. All rights reserved.
NASA Astrophysics Data System (ADS)
Pang, Suh Chyn; Masjuki, Haji Hassan; Kalam, Md. Abul; Hazrat, Md. Ali
2014-01-01
Automotive designers should design a robust engine cooling system which works well in both normal and severe driving conditions. When vehicles are keyed-off suddenly after some distance of hill-climbing driving, the coolant temperature tends to increase drastically. This is because heat soak in the engine could not be transferred away in a timely manner, as both the water pump and cooling fan stop working after the vehicle is keyed-off. In this research, we aimed to visualize the coolant temperature trend over time before and after the vehicles were keyed-off. In order to prevent coolant temperature from exceeding its boiling point and jeopardizing engine life, a numerical model was further tested with prolonged fan and/or water pump operation after keying-off. One dimensional thermal-fluid simulation was exploited to model the vehicle's cooling system. The behaviour of engine heat, air flow, and coolant flow over time were varied to observe the corresponding transient coolant temperatures. The robustness of this model was proven by validation with industry field test data. The numerical results provided sensible insights into the proposed solution. In short, prolonging fan operation for 500 s and prolonging both fan and water pump operation for 300 s could reduce coolant peak temperature efficiently. The physical implementation plan and benefits yielded from implementation of the electrical fan and electrical water pump are discussed.
Umakanthan, Ramanan; Dubose, Robert; Byrne, John G; Ahmad, Rashid M
2010-10-01
The management of acute myocardial infarction with resultant acute ischemic mitral regurgitation and acute multi-organ failure can prove to be a very challenging scenario. The presence of concomitant vascular disease can only serve to further compromise the complexity of the situation. We demonstrate a new indication for the transthoracic intra-aortic balloon pump as a preoperative means of unloading the heart and improving clinical outcome in such high-risk patients with severe vascular disease. We present the case of a 75-year-old man with a history of severe vascular disease who was transferred emergently to Vanderbilt University Medical Center with an acute inferolateral wall myocardial infarction resulting in severe acute ischemic mitral regurgitation and acute multi-organ failure. He presented with shock liver (serum glutamic-oxaloacetic transaminase [SGOT] of 958), renal failure (creatinine of 3.0), and respiratory failure with a pH of 7.18. Emergent cardiac catheterization revealed 100% occlusion of the left circumflex artery as well as severe ileofemoral disease. The advanced nature of his ileofemoral disease was such that the arterial access catheter occluded the right femoral artery. The duration of time that the catheter was in the artery led to transient limb ischemia with an elevation of his creatine phosphokinase (CPK) to 10,809. Balloon angioplasty followed by stent placement was successfully performed, which restored flow to the coronary vessel. Given the grave nature of the patient's condition, we were very concerned that immediate operative intervention for his condition would entail prohibitively high risk. In fact, the Society of Thoracic Surgeons predicted risk adjusted mortality was calculated to be 56%. In order to minimize patient mortality and morbidity, it was critical to help restore perfusion and organ recovery. Therefore, we decided that the chances for this patient's survival would improve if his condition could be optimized by placement of an intra-aortic balloon pump before undergoing surgery. Given the limb ischemia following arterial sheath insertion, femoral placement of an intra-aortic balloon pump was not an option. Placement of the intra-aortic balloon pump was attempted via a left subclavian artery cutdown, but was not successful. Therefore, a sternotomy was performed, and we placed a transthoracic intra-aortic balloon pump in order to stabilize the patient's hemodynamics and allow for organ recovery. The patient showed immediate improvement, and 4 days later, the multi-organ failure resolved and he successfully underwent mitral valve replacement. The patient was ultimately discharged to a local rehabilitation facility in satisfactory condition. This case demonstrates the utility of a transthoracic intra-aortic balloon pump as a preoperative means of stabilization in very high risk patients with severe peripheral vascular disease in whom the conventional approaches are not possible.
Heerdt, P M; Pond, C G; Kussman, M K; Triantafillou, A N
1993-01-01
Despite numerous technologic advances in intraoperative monitoring, the only methods routinely available for assessment of right ventricular function in lung transplant recipients are continuous measurement of right heart pressures and intermittent thermodilution determination of cardiac output and ejection fraction. Additional data may now be obtained with transesophageal echocardiography, although this technology is expensive and not widely available and requires diverting attention from a potentially unstable patient for data acquisition and analysis. Recently, a Doppler pulmonary artery catheter was introduced that measures beat-to-beat pulmonary artery blood flow-velocity, cross sectional area, and volume flow. Because of data indicating that acceleration of blood in the pulmonary artery (measured as the first derivative of either the velocity or flow waveform) is a sensitive indicator of right ventricular contractility, we have used waveforms obtained with the catheter for assessment of right ventricular pump function (stroke volume and peak pulmonary artery flow rate) and contractility in heart surgery patients. We report here our experience with this method in two patients undergoing left single lung transplantation.
Mean Line Pump Flow Model in Rocket Engine System Simulation
NASA Technical Reports Server (NTRS)
Veres, Joseph P.; Lavelle, Thomas M.
2000-01-01
A mean line pump flow modeling method has been developed to provide a fast capability for modeling turbopumps of rocket engines. Based on this method, a mean line pump flow code PUMPA has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The pump code can model axial flow inducers, mixed-flow and centrifugal pumps. The code can model multistage pumps in series. The code features rapid input setup and computer run time, and is an effective analysis and conceptual design tool. The map generation capability of the code provides the map information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of the code permit parametric design space exploration of candidate pump configurations and provide pump performance data for engine system evaluation. The PUMPA code has been integrated with the Numerical Propulsion System Simulation (NPSS) code and an expander rocket engine system has been simulated. The mean line pump flow code runs as an integral part of the NPSS rocket engine system simulation and provides key pump performance information directly to the system model at all operating conditions.
Kolyva, Christina; Biglino, Giovanni; Pepper, John R; Khir, Ashraf W
2012-03-01
A mock circulatory system (MCS) was designed to replicate a physiological environment for in vitro testing and was assessed with the intra-aortic balloon pump (IABP). The MCS was comprised of an artificial left ventricle (LV), connected to a 14-branch polyurethane-compound aortic model. Physiological distribution of terminal resistance and compliance according to published data was implemented with capillary tubes of different sizes and syringes of varying air volume, respectively, fitted at the outlets of the branches. The ends of the aortic branches were connected to a common tube representing the venous system and an overhead reservoir provided atrial pressure. An IABP operating a 40-cc balloon was set to counterpulsate with the LV. Total arterial compliance of the system was 0.94 mL/mm Hg and total arterial resistance was 20.3 ± 3.3 mm Hg/L/min. At control, physiological flow distribution was achieved and both mean and phasic aortic pressure and flow were physiological. With the IABP, aortic pressure exhibited the major features of counterpulsation: diastolic augmentation during inflation, inflection point at onset of deflation, and end-diastolic reduction at the end of deflation. The contribution of balloon inflation and deflation was also evident on the aortic flow pattern. This MCS was verified to be suitable for IABP testing and with further adaptations it could be used for studying other hemodynamic problems and ventricular assist devices. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
An artificial right ventricle for failing fontan: in vitro and computational study.
Lacour-Gayet, François G; Lanning, Craig J; Stoica, Serban; Wang, Rui; Rech, Bryan A; Goldberg, Steven; Shandas, Robin
2009-07-01
The aim of this study is to develop a destination low-pressure artificial right ventricle (ARV) to correct the impaired hemodynamics in the failing Fontan circulation. An in vitro model circuit of the Fontan circulation was created to reproduce the hemodynamics of the failing Fontan and test ARV performance under various central venous pressures (CVP) and flows. A novel geometry of the extracardiac conduit was designed to adapt to the need of the pump. The ARV was a low-pressure axial flow pump designed to produce a low suction inflow pressure and moderate outflow increase. With the power off, the passive forward gradient across the propeller is 2 mm Hg at 4.5 L/min. The ARV would require 4 watts at a rotation of 5000 rpm. To examine the shear loading on the red blood cells, virtual particles were injected upstream of the ARV inducer and tracked by computerized modeling. The effect of the ARV on the failing Fontan was studied at various CVP pressures and flows, and under constant values of lung resistances and left atrial pressure set respectively to 2.5 Woods Units and 7 mm Hg. The CVP pressures decreased respectively from 25, 22.5, 20, 17.5, 15, and 10 mm Hg to a minimal value of 2 to 5 mm Hg with a pump speed varying from 1700 to 4500 rpm. The pulmonary artery pressures increased moderately between 12.5 and 25 mm Hg at 4500 rpm. Cardiac output at 4500 rpm was increased by an average gain of 2 L/min. The average blood damage index was 0.92%, far below the 5% value considered to cause hemolysis. The flow structure produced by the pump was suitable. The performance of this novel low-pressure ARV was satisfactory, showing good decrease of CVP pressures, a moderate increase of pulmonary artery pressures, adequate increase of cardiac output, and minimal hemolysis. The use of a mock Fontan model circuit facilitates device prototyping and design to a far greater extent than can be achieved using animal studies, and is an essential first step for rapid design iteration of a novel ARV device. The next steps are the manufacturing of this device, including an electromagnetic engine, a regulatory system, and further testing the device in a survival animal experiment.
Momose, Naoki; Yamakoshi, Rie; Kokubo, Ryo; Yasuda, Toru; Iwamoto, Norio; Umeda, Chinori; Nakajima, Itsuro; Yanagisawa, Mitsunobu; Tomizawa, Yasuko
2010-03-01
We developed a simple device that stabilizes the blood level in the reservoir of the extracorporeal circulation open circuit system by measuring the hydrostatic pressure of the reservoir to control the flow rate of the arterial pump. When the flow rate of the venous return decreases, the rotation speed of the arterial pump is automatically slowed down. Consequently, the blood level in the reservoir is stabilized quickly between two arbitrarily set levels and never falls below the pre-set low level. We conducted a basic experiment to verify the operation of the device, using a mock circuit with water. Commercially available pumps and reservoir were used without modification. The results confirmed that the control method effectively regulates the reservoir liquid level and is highly reliable. The device possibly also functions as a safety device.
Rocha Ferreira, Graziela Santos; de Almeida, Juliano Pinheiro; Landoni, Giovanni; Vincent, Jean Louis; Fominskiy, Evgeny; Gomes Galas, Filomena Regina Barbosa; Gaiotto, Fabio A; Dallan, Luís Oliveira; Franco, Rafael Alves; Lisboa, Luiz Augusto; Palma Dallan, Luis Roberto; Fukushima, Julia Tizue; Rizk, Stephanie Itala; Park, Clarice Lee; Strabelli, Tânia Mara; Gelas Lage, Silvia Helena; Camara, Ligia; Zeferino, Suely; Jardim, Jaquelline; Calvo Arita, Elisandra Cristina Trevisan; Caldas Ribeiro, Juliana; Ayub-Ferreira, Silvia Moreira; Costa Auler, Jose Otavio; Filho, Roberto Kalil; Jatene, Fabio Biscegli; Hajjar, Ludhmila Abrahao
2018-04-30
The aim of this study was to evaluate the efficacy of perioperative intra-aortic balloon pump use in high-risk cardiac surgery patients. A single-center randomized controlled trial and a meta-analysis of randomized controlled trials. Heart Institute of São Paulo University. High-risk patients undergoing elective coronary artery bypass surgery. Patients were randomized to receive preskin incision intra-aortic balloon pump insertion after anesthesia induction versus no intra-aortic balloon pump use. The primary outcome was a composite endpoint of 30-day mortality and major morbidity (cardiogenic shock, stroke, acute renal failure, mediastinitis, prolonged mechanical ventilation, and a need for reoperation). A total of 181 patients (mean [SD] age 65.4 [9.4] yr; 32% female) were randomized. The primary outcome was observed in 43 patients (47.8%) in the intra-aortic balloon pump group and 42 patients (46.2%) in the control group (p = 0.46). The median duration of inotrope use (51 hr [interquartile range, 32-94 hr] vs 39 hr [interquartile range, 25-66 hr]; p = 0.007) and the ICU length of stay (5 d [interquartile range, 3-8 d] vs 4 d [interquartile range, 3-6 d]; p = 0.035) were longer in the intra-aortic balloon pump group than in the control group. A meta-analysis of 11 randomized controlled trials confirmed a lack of survival improvement in high-risk cardiac surgery patients with perioperative intra-aortic balloon pump use. In high-risk patients undergoing cardiac surgery, the perioperative use of an intra-aortic balloon pump did not reduce the occurrence of a composite outcome of 30-day mortality and major complications compared with usual care alone.
Pump efficiency in solar-energy systems
NASA Technical Reports Server (NTRS)
1978-01-01
Study investigates characteristics of typical off-the-shelf pumping systems that might be used in solar systems. Report includes discussion of difficulties in predicting pump efficiency from manufacturers' data. Sample calculations are given. Peak efficiencies, flow-rate control, and noise levels are investigated. Review or theory of pumps types and operating characteristics is presented.
[System analytical approach of lung function and hemodynamics].
Naszlady, Attila; Kiss, Lajos
2009-02-15
The authors critically analyse the traditional views in physiology and complete them with new statements based on computer model simulations of lung function and of hemodynamics. Conclusions are derived for the clinical practice as follows: the four-dimensional function curves are similar in both systems; there is a "waterfall" zone in the pulmonary blood perfusion; the various time constants of pulmonary regions can modify the blood gas values; pulmonary capillary pressure is equal to pulmonary arterial diastole pressure; heart is not a pressure pump, but a flow source; ventricles are loaded by the input impedance of the arterial systems and not by the total vascular (ohmlike) resistance; optimum heart rate in rest depends on the length of the aorta; this law of heart rate, based on the principle of resonance is valid along the mammalian allometric line; tachycardia decreases the input impedance; using positive end expiratory pressure respirators the blood gas of pulmonary artery should be followed; coronary circulation should be assessed in beat per milliliter, the milliliter per minute may be false. These statements are compared to related references.
DOT National Transportation Integrated Search
2010-11-01
This study developed an integrated control model to contend with the impact of off-ramp queue spillback on both the freeway and arterials within the interchange control boundaries. The entire control system consists of two levels that compute the opt...
1981-01-01
SELCAL FLT ALT ATNI AUO ALT BRK CANSELCAL OVSO CALL CONTRL ALRT _ I7CT be SPLR b 0 11CALL Figure 5.4.4-1 Pilot’s Response Panel Figure 5.4.4-2 Flight...Galley bus off 27 GLY BUS OFF A RP ELEC CYCLE SWITCH Utility bus off 28 UTIL BUS OFF A RP ELEC CYCLE SWITCH Right engine 29 R ENG HYD PUMP A RP HYD...CYCLE SWITCH hydraulic pump Left engine 30 L ENG FIRE DET A RP FIRE RP FIRE fire detector Left brake overheat 31 L BRAKE OVHT A RP BRK RP BRK Right
Blaustein, Mordecai P
2018-01-01
Two prescient 1953 publications set the stage for the elucidation of a novel endocrine system: Schatzmann's report that cardiotonic steroids (CTSs) are all Na + pump inhibitors, and Szent-Gyorgi's suggestion that there is an endogenous "missing screw" in heart failure that CTSs like digoxin may replace. In 1977 I postulated that an endogenous Na + pump inhibitor acts as a natriuretic hormone and simultaneously elevates blood pressure (BP) in salt-dependent hypertension. This hypothesis was based on the idea that excess renal salt retention promoted the secretion of a CTS-like hormone that inhibits renal Na + pumps and salt reabsorption. The hormone also inhibits arterial Na + pumps, elevates myocyte Na + and promotes Na/Ca exchanger-mediated Ca 2+ gain. This enhances vasoconstriction and arterial tone-the hallmark of hypertension. Here I describe how those ideas led to the discovery that the CTS-like hormone is endogenous ouabain (EO), a key factor in the pathogenesis of hypertension and heart failure. Seminal observations that underlie the still-emerging picture of the EO-Na + pump endocrine system in the physiology and pathophysiology of multiple organ systems are summarized. Milestones include: 1) cloning the Na + pump isoforms and physiological studies of mutated pumps in mice; 2) discovery that Na + pumps are also EO-triggered signaling molecules; 3) demonstration that ouabain, but not digoxin, is hypertensinogenic; 4) elucidation of EO's roles in kidney development and cardiovascular and renal physiology and pathophysiology; 5) discovery of "brain ouabain", a component of a novel hypothalamic neuromodulatory pathway; and 6) finding that EO and its brain receptors modulate behavior and learning.
Non-invasive determination of instantaneous brachial blood flow using the oscillometric method.
Liu, Shing-Hong; Wang, Jia-Jung; Cheng, Da-Chuan
2009-08-01
The oscillometric method has been widely used to measure arterial systolic and diastolic blood pressures, but its potential for arterial blood flow measurements still remains to be explored. The aim of this study was to non-invasively determine arterial blood flow using an oscillometric blood flow measurement system. The system consists of a pneumatic elastic cuff, an air-pumping motor, a releaser valve, a pressure transducer, and an airflow meter. To build a non-linear cuff model, we measured airflow pumped into the pneumatic cuff and cuff pressure using an airflow meter and pressure transducer during the inflation period, respectively. During the deflation period, only the pressure transducer was used to record cuff pressure. Based on the cuff model, the oscillometric blood flow waveform was obtained by integrating the oscillometric pressure waveform. We compared arterial blood flow derived from the maximum amplitude of the oscillometric blood flow waveform with Doppler-measured blood flow calculated with the diameters and blood velocities of the brachial arteries in 32 subjects who underwent diagnostic evaluations for peripheral arterial embolism. A linear correlation coefficient of r = 0.716 was found between the oscillometry- and Doppler-based blood flow measurements in the 32 subjects. These results suggest that blood flow passing through the brachial artery can be quantified non-invasively using the oscillometric approach after appropriate calibration.
Temporal patterns of physical activity in Olympic dinghy racing.
Legg, S; Mackie, H; Smith, P
1999-12-01
The objective of the present study was to determine the temporal patterns of physical activity in four classes of Olympic racing dinghy. Descriptive. A field (on-water) study. Nineteen elite New Zealand sailors (fifteen male and four female). Not applicable. The temporal pattern (duration and frequency) and nature of the physical activities of each sailor during each leg of simulated races were recorded on video tape and subsequently systematically quantified and categorised using notational analysis. The accumulated percentage of total leg time spent sitting (upright or leaning backwards), hiking (upright or fully extended) whilst trimming and whilst pumping the mainsheet and for the time spent on rig adjustments, tacking and gybing were calculated for both up-wind and off-wind sailing. When sailing up-wind, the most time was spent hiking upright (average 29-66% of total leg time) while trimming the mainsheet. During off-wind sailing, sailors spent the most time sitting upright while trimming the mainsheet (average 29-55% total leg time). Hiking upright while trimming the mainsheet was executed the greatest number of times (average 15.8-23.9) when sailing up-wind and sitting upright while trimming was executed the most times (average 3.5-7.4) when sailing off-wind. The most lengthy continuous activity was hiking upright while trimming the mainsheet when sailing up-wind (9-18 seconds) and sitting upright while trimming the mainsheet when sailing off-wind (17-34 seconds). The most physically demanding aspect of Olympic yacht racing is hiking. It occurs for the majority of up-wind legs when the wind starts to exceed approximately 8 knots. The only respite that the sailor gets from hiking is during tacking, rig adjustments or sitting in-board for brief periods when the wind is low. Sustained hiking tends to last for no more than approximately 20 seconds before the sailor changes to either a more extended or more upright hiking posture. The physical demands during off-wind sailing are generally less, except for a greater requirement for power in the arms and shoulders to pump the mainsheet in order to assist the dinghy in accelerating down waves. The findings of the present study are directly applicable to the design of sailing specific physical conditioning programmes for Olympic class sailors.
Stehouwer, Marco C; de Vroege, Roel; Hoohenkerk, Gerard J F; Hofman, Frederik N; Kelder, Johannes C; Buchner, Bas; de Mol, Bastian A; Bruins, Peter
2017-11-01
Recently, an oxygenator with an integrated centrifugal blood pump (IP) was designed to minimize priming volume and to reduce blood foreign surface contact even further. The use of this oxygenator with or without integrated arterial filter was compared with a conventional oxygenator and nonintegrated centrifugal pump. To compare the air removal characteristics 60 patients undergoing coronary artery bypass grafting were alternately assigned into one of three groups to be perfused with a minimized extracorporeal circuit either with the conventional oxygenator, the oxygenator with IP, or the oxygenator with IP plus integrated arterial filter (IAF). Air entering and leaving the three devices was measured accurately with a bubble counter during cardiopulmonary bypass. No significant differences between all groups were detected, considering air entering the devices. Our major finding was that in both integrated devices groups incidental spontaneous release of air into the arterial line in approximately 40% of the patients was observed. Here, detectable bolus air (>500 µm) was shown in the arterial line, whereas in the minimal extracorporeal circulation circuit (MECC) group this phenomenon was not present. We decided to conduct an amendment of the initial design with METC-approval. Ten patients were assigned to be perfused with an oxygenator with IP and IAF. Importantly, the integrated perfusion systems used in these patients were flushed with carbon dioxide (CO 2 ) prior to priming of the systems. In the group with CO 2 flush no spontaneous air release was observed in all cases and this was significantly different from the initial study with the group with the integrated device and IAF. This suggests that air spilling may be caused by residual air in the integrated device. In conclusion, integration of a blood pump may cause spontaneous release of large air bubbles (>500 µm) into the arterial line, despite the presence of an integrated arterial filter. CO 2 flushing of an integrated cardiopulmonary bypass system prior to priming may prevent spontaneous air release and is strongly recommended to secure patient safety. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
B-1 Systems Approach to Training. Task Analysis Listings
1975-07-01
OFF FUEL VALVES AND PUMPS PHR-OFF FUEL VALVES AND PUMPS = AUTO ^FT TFR MODE LAND SELECTOR SWITCHES TQ *QFF...TFR MODE SWITCH-RIGHT «JFT L TFR MODE SELECT SWITCH TQ * TF1 CHECKLIST TFR MODE SWITCH-LEFT TFR MODE SWITCH-LEFT...DOOR HANDLE ENTRY LADDER CONTROL SWITCH ENTRY LADDER CONTROL SWITCH = DN* 16.1.1.001.OC* SET TANK FILL VALVE SWS ON
Emery, Robert W; Solien, Eric
2013-01-01
The aim of this study was to determine whether the eSVS Mesh interferes with transit-time flow measurement (TTFM) assessing intraoperative coronary vein graft patency. In four swine undergoing off-pump bypass grafting to the anterior descending coronary artery, five TTFMs were sequentially obtained on meshed and bare grafts at baseline and under Dobutamine stress at five separate locations on the graft in each animal. The Medistim VeriQ was used for TTFM. The grafts were examined for patency after the swine were killed. There was no difference in hemodynamics or TTFM either at baseline or under Dobutamine stress between the eSVS Mesh covered and uncovered grafts. Dobutamine, however, significantly increased hemodynamics and graft flow parameters measured from baseline. The eSVS Mesh does not interfere with Doppler flow measurement in covered coronary vein grafts.
2014-01-01
Background End-to-side anastomoses to connect the distal end of the great saphenous vein (GSV) to small target coronary arteries are commonly performed in sequential coronary artery bypass grafting (CABG). However, the oversize diameter ratio between the GSV and small target vessels at end-to-side anastomoses might induce adverse hemodynamic condition. The purpose of this study was to describe a distal end side-to-side anastomosis technique and retrospectively compare the effect of distal end side-to-side versus end-to-side anastomosis on graft flow characteristics. Methods We performed side-to-side anastomoses to connect the distal end of the GSV to small target vessels on 30 patients undergoing off-pump sequential CABG in our hospital between October 2012 and July 2013. Among the 30 patients, end-to-side anastomoses at the distal end of the GSV were initially performed on 14 patients; however, due to poor graft flow, those anastomoses were revised into side-to-side anastomoses. We retrospectively compared the intraoperative graft flow characteristics of the end-to-side versus side-to-side anastomoses in the 14 patients. The patient outcomes were also evaluated. Results We found that the side-to-side anastomosis reconstruction improved intraoperative flow and reduced pulsatility index in all the 14 patients significantly. The 16 patients who had the distal end side-to-side anastomoses performed directly also exhibited satisfactory intraoperative graft flow. Three-month postoperative outcomes for all the patients were satisfactory. Conclusions Side-to-side anastomosis at the distal end of sequential vein grafts might be a promising strategy to connect small target coronary arteries to the GSV. PMID:24884776
Selective Arterial Clamping Versus Hilar Clamping for Minimally Invasive Partial Nephrectomy.
Yezdani, Mona; Yu, Sue-Jean; Lee, David I
2016-05-01
Partial nephrectomy has become an accepted treatment of cT1 renal masses as it provides improved long-term renal function compared to radical nephrectomy (Campbell et al. J Urol. 182:1271-9, 2009). Hilar clamping is utilized to help reduce bleeding and improve visibility during tumor resection. However, concern over risk of kidney injury with hilar clamping has led to new techniques to reduce length of warm ischemia time (WIT) during partial nephrectomy. These techniques have progressed over the years starting with early hilar unclamping, controlled hypotension during tumor resection, selective arterial clamping, minimal margin techniques, and off-clamp procedures. Selective arterial clamping has progressed significantly over the years. The main question is what are the exact short- and long-term renal effects from increasing clamp time. Moreover, does it make sense to perform these more time-consuming or more complex procedures if there is no long-term preservation of kidney function? More recent studies have shown no difference in renal function 6 months from surgery when selective arterial clamping or even hilar clamping is employed, although there is short-term improved decline in estimated glomerular filtration rate (eGFR) with selective clamping and off-clamp techniques (Komninos et al. BJU Int. 115:921-8, 2015; Shah et al. 117:293-9, 2015; Kallingal et al. BJU Int. doi: 10.1111/bju.13192, 2015). This paper reviews the progression of total hilar clamping to selective arterial clamping (SAC) and the possible difference its use makes on long-term renal function. SAC may be attempted based on surgeon's decision-making, but may be best used for more complex, larger, more central or hilar tumors and in patients who have renal insufficiency at baseline or a solitary kidney.
Medizade, Masoud [San Luis Obispo, CA; Ridgely, John Robert [Los Osos, CA
2009-12-15
An arrangement which utilizes an inexpensive flap valve/flow transducer combination and a simple local supervisory control system to monitor and/or control the operation of a positive displacement pump used to extract petroleum from geologic strata. The local supervisory control system controls the operation of an electric motor which drives a reciprocating positive displacement pump so as to maximize the volume of petroleum extracted from the well per pump stroke while minimizing electricity usage and pump-off situations. By reducing the electrical demand and pump-off (i.e., "pounding" or "fluid pound") occurrences, operating and maintenance costs should be reduced sufficiently to allow petroleum recovery from marginally productive petroleum fields. The local supervisory control system includes one or more applications to at least collect flow signal data generated during operation of the positive displacement pump. No flow, low flow and flow duration are easily evaluated using the flap valve/flow transducer arrangement.
Hunt, Adam; Waldin, Owen; Slim, Hani; Brar, Ranjeet
2016-06-06
This is a unique case report describing complex limb salvage in a patient who experienced acute limb ischaemia due to a complication of intra-aortic balloon pump (IABP) counterpulsation. This case focuses on a patient who had an IABP counterpulsation device inserted following myocardial infarction, requiring urgent coronary artery bypass grafting for acute coronary syndrome. Postoperatively, the IABP could not be removed, with consequent iliac thrombosis and acute limb ischaemia. Emergency femoral-to-femoral crossover bypass was performed using a polytetrafluoroethylene graft. A portion of the IABP balloon tip was entrapped and retained, however, and became the focus of delayed septicaemia, resulting in graft infection and wound breakdown 6 weeks later. Explantation of the residual balloon tip, ligation of the right external iliac artery and redo femoral-femoral crossover using the great saphenous vein were successfully performed. 2016 BMJ Publishing Group Ltd.
Impact of Ultrafiltration on Kidney Injury After Cardiac Surgery: The Michigan Experience.
Paugh, Theron A; Dickinson, Timothy A; Martin, James R; Hanson, Eric C; Fuller, John; Heung, Michael; Zhang, Min; Shann, Kenneth G; Prager, Richard L; Likosky, Donald S
2015-11-01
This study examines the relationship between the use and volume of conventional ultrafiltration (CUF) and the risk of acute kidney injury (AKI) after isolated on-pump coronary artery bypass graft surgery. A total of 6,407 consecutive patients underwent isolated on-pump coronary artery bypass graft surgery between 2010 and 2013 at 21 medical centers participating in the PERFusion Measures and Outcomes (PERForm) registry. We assessed the effect of CUF use on AKI and other postoperative sequelae using a generalized linear mixed-effect model with a logit link. We also modeled the effect of increasing volume of CUF per weight on AKI, and tested for any modification by a patient's preoperative kidney function. Patients having CUF were more likely to have diabetes, vascular disease, chronic obstructive pulmonary disease, congestive heart failure, history of a myocardial infarction, or an intraaortic balloon pump (p < 0.05). They had lower preoperative and nadir hematocrits, creatinine clearance, and ejection fraction (p < 0.05). Patients exposed to CUF had higher adjusted risk of AKI (adjusted odds ratio, 1.36; p = 0.002), although similar rates of death, stroke, and reoperation for bleeding (p > 0.05). The risk of AKI was modified by a patient's preoperative kidney function (p < 0.0004). Among patients with a creatinine clearance of less than 99.6 mL/min (95% confidence interval, 67.6 to 137.5), increasing volume of CUF was associated with a higher risk of AKI. Patients exposed to CUF had a higher adjusted risk of AKI. Clinical teams should consider lower volumes of CUF among patients with low creatinine clearance to minimize the risk of AKI. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Georgiades, Christos, E-mail: g_christos@hotmail.com; Rodriguez, Ronald, E-mail: rrodrig@jhmi.edu; Azene, Ezana, E-mail: eazene1@jhmi.edu
2013-06-15
Objective. The study was designed to determine the distance between the visible 'ice-ball' and the lethal temperature isotherm for normal renal tissue during cryoablation. Methods. The Animal Care Committee approved the study. Nine adult swine were used: three to determine the optimum tissue stain and six to test the hypotheses. They were anesthetized and the left renal artery was catheterized under fluoroscopy. Under MR guidance, the kidney was ablated and (at end of a complete ablation) the nonfrozen renal tissue (surrounding the 'ice-ball') was stained via renal artery catheter. Kidneys were explanted and sent for slide preparation and examination. Frommore » each slide, we measured the maximum, minimum, and an in-between distance from the stained to the lethal tissue boundaries (margin). We examined each slide for evidence of 'heat pump' effect. Results. A total of 126 measurements of the margin (visible 'ice-ball'-lethal margin) were made. These measurements were obtained from 29 slides prepared from the 6 test animals. Mean width was 0.75 {+-} 0.44 mm (maximum 1.15 {+-} 0.51 mm). It was found to increase adjacent to large blood vessels. No 'heat pump' effect was noted within the lethal zone. Data are limited to normal swine renal tissue. Conclusions. Considering the effects of the 'heat pump' phenomenon for normal renal tissue, the margin was measured to be 1.15 {+-} 0.51 mm. To approximate the efficacy of the 'gold standard' (partial nephrectomy, {approx}98 %), a minimum margin of 3 mm is recommended (3 Multiplication-Sign SD). Given these assumptions and extrapolating for renal cancer, which reportedly is more cryoresistant with a lethal temperature of -40 Degree-Sign C, the recommended margin is 6 mm.« less
An avulsed radial artery with a high take-off.
Rojas-Marte, Geurys; Chen, On; Verma, Shivani; Rao, Atul; Shani, Jacob; Ayzenberg, Sergey
2015-04-01
A 63-year-old female was diagnosed with severe aortic stenosis, who underwent a diagnostic coronary angiography via transradial approach prior an aortic-valve replacement. After imaging the left coronary system, entrapment of the diagnostic catheter was encountered as a result of spasm of the radial artery. An arteriogram of the arm revealed an anatomical variation in the radial artery (high take-off). Several attempts to remove the entrapped catheter resulted in avulsion of the artery, which was managed successfully with coil embolization. To our knowledge, no such complication has been reported. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Ng, Boon C.; Timms, Daniel; Cohn, William E.
2018-01-01
Despite the widespread acceptance of rotary blood pump (RBP) in clinical use over the past decades, the diminished flow pulsatility generated by a fixed speed RBP has been regarded as a potential factor that may lead to adverse events such as vasculature stiffening and hemorrhagic strokes. In this study, we investigate the feasibility of generating physiological pulse pressure in the pulmonary circulation by modulating the speed of a right ventricular assist device (RVAD) in a mock circulation loop. A rectangular pulse profile with predetermined pulse width has been implemented as the pump speed pattern with two different phase shifts (0% and 50%) with respect to the ventricular contraction. In addition, the performance of the speed modulation strategy has been assessed under different cardiovascular states, including variation in ventricular contractility and pulmonary arterial compliance. Our results indicated that the proposed pulse profile with optimised parameters (Apulse = 10000 rpm and ωmin = 3000 rpm) was able to generate pulmonary arterial pulse pressure within the physiological range (9–15 mmHg) while avoiding undesirable pump backflow under both co- and counter-pulsation modes. As compared to co-pulsation, stroke work was reduced by over 44% under counter-pulsation, suggesting that mechanical workload of the right ventricle can be efficiently mitigated through counter-pulsing the pump speed. Furthermore, our results showed that improved ventricular contractility could potentially lead to higher risk of ventricular suction and pump backflow, while stiffening of the pulmonary artery resulted in increased pulse pressure. In conclusion, the proposed speed modulation strategy produces pulsatile hemodynamics, which is more physiologic than continuous blood flow. The findings also provide valuable insight into the interaction between RVAD speed modulation and the pulmonary circulation under various cardiovascular states. PMID:29677212
Song, Jong Wook; Shim, Jae Kwang; Soh, Sarah; Jang, Jaewon; Kwak, Young Lan
2015-02-01
The aim of this study was to investigate the influence of perioperative N-acetylcysteine (NAC) administration, a known antioxidant, on the incidence of acute kidney injury (AKI) after off-pump coronary bypass surgery (OPCAB) in patients with known risk factors of AKI. One hundred and seventeen patients with ≥1 of the following risk factors of AKI were randomized into either the control (n = 57) or the NAC (n = 60) group; (i) preoperative serum creatinine >1.4 mg/dL; (ii) left ventricular ejection fraction <35% or congestive heart failure (iii) age >70 years (iv) diabetes or (v) re-operation. Patients in the NAC group received 150 mg/kg of NAC IV bolus at anaesthetic induction followed by a continuous infusion at 150 mg/kg per day for 24 h. AKI was diagnosed based on Acute Kidney Injury Network criteria during 48 h postoperatively. The incidence of AKI was 32% (19/60) and 35% (20/57) in the control and the NAC group, respectively (P = 0.695). The serum concentrations of creatinine and cystatin C were similar between the groups throughout the study period. Fluid balance including the amount of blood loss and transfusion requirement were similar between the groups except the amount of postoperative urine output, which was higher in the control group compared with the NAC group (5528 ± 1247 mL vs. 4982 ± 1185 mL, control vs. NAC, P = 0.017). Perioperative administration of NAC did not prevent the development of postoperative AKI after OPCAB in highly susceptible patients to AKI. © 2014 Asian Pacific Society of Nephrology.
Berger, Peter B; Kirchner, H Lester; Wagner, Eric S; Ismail-Sayed, Ibrahim; Yahya, Salma; Benoit, Charles; Blankenship, James C; Carter, Russell; Casale, Alfred S; Green, Sandy M; Scott, Thomas D; Skelding, Kimberly A; Woods, Edward; Henry, Yvette M
2015-06-01
We sought to examine the relationship between preoperative platelet function and perioperative bleeding in patients undergoing CABG. There are many ways to measure platelet aggregability. Little is known about their correlations with one another, or with bleeding. We prospectively studied 50 patients undergoing a first isolated off-pump CABG. Thirty-four were exposed to a thienopyridine prior to surgery; 16 were not. Preoperative platelet function was measured by VerifyNow®, TEG®, AggreGuide™, Plateletworks®, vasodilator-stimulated phosphoprotein (VASP) phosphorylation, and light transmission aggregometry. Bleeding was assessed 2 ways: drop from pre- to nadir postoperative hematocrit, and chest tube drainage. Correlation coefficients were calculated using Spearman's rank-order correlation. Mean age was 62 years. Patient characteristics and surgical details were similar between the thienopyridine-exposed and non-exposed patients. The correlation coefficients between the 4 point-of-care platelet function measurements and hematocrit change ranged from -0.2274 to 0.2882. Only Plateletworks® correlated with drop in hematocrit (r = 0.2882, P = 0.0470). The correlation coefficients between each of the 4 point-of-care platelet function tests and the chest tube drainage were also poor, ranging from -0.3073 to 0.2272. Both AggreGuide™ (r = -0.3073, P = 0.0317) and VASP (r = -0.3187, P = 0.0272) were weakly but significantly correlated with chest tube drainage. The correlation among the 4 point-of-care platelet function measurements was poor, with coefficients ranging from -0.2504 to 0.1968. We observed little correlation among 4 platelet function tests, and between those assays and perioperative bleeding defined 2 different ways. Whether any of these assays should be used to guide decision making in individual patients is unclear. © 2015, Wiley Periodicals, Inc.
Pulse Doppler ultrasound as a tool for the diagnosis of chronic testicular dysfunction in stallions
Ortiz-Rodriguez, Jose M.; Anel-Lopez, Luis; Martín-Muñoz, Patricia; Álvarez, Mercedes; Gaitskell-Phillips, Gemma; Anel, Luis; Rodríguez-Medina, Pedro; Peña, Fernando J.
2017-01-01
Testicular function is particularly susceptible to vascular insult, resulting in a negative impact on sperm production and quality of the ejaculate. A prompt diagnosis of testicular dysfunction enables implementation of appropriate treatment, hence improving fertility forecasts for stallions. The present research aims to: (1) assess if Doppler ultrasonography is a good tool to diagnose stallions with testicular dysfunction; (2) to study the relationship between Doppler parameters of the testicular artery and those of sperm quality assessed by flow cytometry and (3) to establish cut off values to differentiate fertile stallions from those with pathologies causing testicular dysfunction. A total of 10 stallions (n: 7 healthy stallions and n: 3 sub-fertile stallions) were used in this study. Two ejaculates per stallion were collected and preserved at 5°C in a commercial extender. The semen was evaluated at T0, T24 and T48h by flow cytometry. Integrity and viability of sperm (YoPro®-1/EthD-1), mitochondrial activity (MitoTracker® Deep Red FM) and the DNA fragmentation index (Sperm Chromatin Structure Assay) were assessed. Doppler parameters were measured at three different locations on the testicular artery (Supratesticular artery (SA); Capsular artery (CA) and Intratesticular artery (IA)). The Doppler parameters calculated were: Resistive Index (RI), Pulsatility Index (PI), Peak Systolic Velocity (PSV), End Diastolic Velocity (EDV), Time Average Maximum Velocity (TAMV), Total Arterial Blood Flow (TABF) and TABF rate. The capsular artery was the most reliable location to carry out spectral Doppler assessment, since blood flow parameters of this artery were most closely correlated with sperm quality parameters. Significant differences in all the Doppler parameters studied were observed between fertile and subfertile stallions (p ≤ 0.05). The principal components analysis assay determined that fertile stallions are characterized by high EDV, TAMV, TABF and TABF rate values (high vascular perfusion). In contrast, subfertile stallions tend to present high values of PI and RI (high vascular resistance). The ROC curves revealed that the best Doppler parameters to predict sperm quality in stallions were: Doppler velocities (PSV, EDV and TAMV), the diameter of the capsular artery and TABF parameters (tissue perfusion parameters). Cut off values were established using a Youden´s Index to identify fertile stallions from stallions with testicular dysfunction. Spectral Doppler ultrasound is a good predictive tool for sperm quality since correlations were determined among Doppler parameters and markers of sperm quality. Doppler ultrasonography could be a valuable diagnostic tool for use by clinical practitioners for the diagnosis of stallions with testicular dysfunction and could be a viable alternative to invasive procedures traditionally used for diagnosis of sub-fertility disorders. PMID:28558006
NASA Astrophysics Data System (ADS)
Pahlevan, Niema; Gharib, Morteza
2012-11-01
Impedance pump is a simple valveless pumping mechanism that operates based on the principles of wave propagation and reflection. It has been shown in a zebrafish that a similar mechanism is responsible for the pumping action in the embryonic heart during early stages before valve formation. Recent studies suggest that the cardiovascular system is designed to take advantage of wave propagation and reflection phenomena in the arterial network. Our aim in this study was to examine if the human aorta is a passive pump working like an impedance pump. A hydraulic model with different compliant models of artificial aorta was used for series of in-vitro experiments. The hydraulic model includes a piston pump that generates the waves. Our result indicates that wave propagation and reflection can create pumping mechanism in a compliant aorta. Similar to an impedance pump, the net flow and the flow direction depends on the frequency of the waves, compliance of the aorta, and the piston stroke.
The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.
Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard
2017-10-01
Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Kohan, Luke C; Nagarajan, Vijaiganesh; Millard, Michael A; Loguidice, Michael J; Fauber, Nancy M; Keeley, Ellen C
2017-01-01
To assess if a change in our cardiology fellowship program impacted our ST elevation myocardial infarction (STEMI) program. Fellows covering the cardiac care unit were spending excessive hours in the hospital while on call, resulting in increased duty hours violations. A night float fellow system was started on July 1, 2012, allowing the cardiac care unit fellow to sign out to a night float fellow at 5:30 pm. The night float fellow remained in-house until the morning. We performed a retrospective study assessing symptom onset to arrival, arterial access to first device, and door-to-balloon (D2B) times, in consecutive STEMI patients presenting to our emergency department before and after initiation of the night float fellow system. From 2009 to 2013, 208 STEMI patients presented to our emergency department and underwent primary percutaneous coronary intervention. There was no difference in symptom onset to arrival (150±102 minutes vs 154±122 minutes, p =0.758), arterial access to first device (12±8 minutes vs 11±7 minutes, p =0.230), or D2B times (50±32 minutes vs 52±34 minutes, p =0.681) during regular working hours. However, there was a significant decrease in D2B times seen during off-hours (72±33 minutes vs 49±15 minutes, p =0.007). There was no difference in in-hospital mortality (11% vs 8%, p =0.484) or need for intra-aortic balloon pump placement (7% vs 8%, p =0.793). In academic medical centers, in-house cardiology fellow coverage during off-hours may expedite care of STEMI patients.
Karlekar, Anil; Bharati, Saswata; Saxena, Ravindra; Mehta, Kanchan
2015-01-01
Background: Laser therapy, for its established analgesic properties with minimal side effects, has been used for the treatment of chronic pain. However, it has not been used for the treatment of acute postoperative pain. This pilot study was designed to assess the feasibility and efficacy of Class IV laser on postoperative pain relief following off-pump coronary artery bypass graft (OPCABG) surgery, as a component of multimodal analgesia (MMA) technique. Methods: This open observational prospective study comprised of 100 adult patients (84 male, 16 female) who underwent OPCABG through sternotomy. For postoperative analgesia, they were subjected to laser therapy subjected to laser therapy in addition to the standard institutional pain management protocol comprising of IV infusion/bolus of tramadol and paracetamol and fentanyl bolus as rescue analgesic. Pain intensity was measured by Verbal Rating Scale (VRS). The laser therapy was scheduled as once a day regime for three consecutive postoperative days (PODs) starting on POD 1, 30 min following tracheal extubation. The subsequent laser applications were also scheduled at the same time of the day as on day 1 if VRS was ≥5. 10 W Class IV laser was applied over 150 cm2 sternal wound area for 150 s. VRS was used to assess pain severity and was recorded for statistical analysis using Friedman Test. Results: The mean (standard deviation [SD]) VRS of all the 100 patients just before application of the first dose of laser was 7.31 (0.94) while on MMT; the same fell to 4.0 (1.279) and 3.40 (2.697) at 1 h and 24 h respectively following first dose of laser. The change of VRS over first 24 h among all the 100 patients was statistically significant (P = 0.000). Laser was re-applied in 40 patients whose VRS was ≥5 (mean [SD] – 6.38 [0.868]) at 24th h. After receiving the 2nd dose of laser the VRS scores fell significantly (P = 0.000) and became 0 at 54th h. No patients required 3rd dose of the laser. No patient required rescue analgesic while on laser therapy. Conclusion: Class IV laser can be an effective technique for postoperative analgesia following OPCABG surgery through sternotomy when included as a component of MMA technique. PMID:26139735
Fiber Raman laser and amplifier pumped by Nd3+:YVO4 solid state laser
NASA Astrophysics Data System (ADS)
Liu, Deming; Zhang, Minming; Liu, Shuang; Nie, Mingju; Wang, Ying
2005-04-01
Pumping source is the key technology of fiber Raman amplifiers (FRA) which are important for ultra long haul and high bit rate dense wavelength division multiplexing (DWDM) systems. In this paper the research work of the project, "Fiber Raman Laser and Amplifier pumped by Nd3+:YVO4 Solid State Laser", supported by the National High-tech Program (863-program) of China is introduced, in which a novel 14xx nm pump module with fine characteristics of high efficiency, simplicity, compactness and low cost is researched and developed. A compact 1342 nm Nd3+:YVO4 diode pumped solid state laser (DPSSL) module is developed with the total laser power of 655mW and the slope efficiency of 42.6% pumped by a 2W 808nm laser diode (LD). A special C-lens fiber collimator is designed to couple the 1342nm laser beam into a piece of single mode fiber (SMF) and the coupling efficiency of 80% is reached. The specific 14xx nm output laser is generated from a single stage Raman resonator which includes a pair of fiber Bragg gratings and a piece of Germanic-silicate or Phospho-silicate fiber pumped by such DPSSL module. The slope efficiency for conversion from 1342 to 14xx nm radiation is 75% and the laser power is more than 300mW each. Finally, Raman gain experiments are carried out with 100km SMF. 100 nm bandwidth with 10dB on-off Raman gain and 1.1dB gain flatness is achieved by pumped at 1425, 1438, 1455 and 1490nm.
Suchoza, Bernard P.; Becse, Imre
1988-01-01
An apparatus for measuring the hydraulic axial thrust of a pump under operation conditions is disclosed. The axial thrust is determined by forcing the rotating impeller off of an associated thrust bearing by use of an elongate rod extending coaxially with the pump shaft. The elongate rod contacts an impeller retainer bolt where a bearing is provided. Suitable measuring devices measure when the rod moves to force the impeller off of the associated thrust bearing and the axial force exerted on the rod at that time. The elongate rod is preferably provided in a housing with a heat dissipation mechanism whereby the hot fluid does not affect the measuring devices.
Suchoza, B.P.; Becse, I.
1988-11-08
An apparatus for measuring the hydraulic axial thrust of a pump under operation conditions is disclosed. The axial thrust is determined by forcing the rotating impeller off of an associated thrust bearing by use of an elongate rod extending coaxially with the pump shaft. The elongate rod contacts an impeller retainer bolt where a bearing is provided. Suitable measuring devices measure when the rod moves to force the impeller off of the associated thrust bearing and the axial force exerted on the rod at that time. The elongate rod is preferably provided in a housing with a heat dissipation mechanism whereby the hot fluid does not affect the measuring devices. 1 fig.
Fransen, Paul; Van Hove, Cor E; Leloup, Arthur J A; Schrijvers, Dorien M; De Meyer, Guido R Y; De Keulenaer, Gilles W
2016-02-01
Arterial hypertension (AHT) affects the voltage dependency of L-type Ca(2+) channels in cardiomyocytes. We analyzed the effect of angiotensin II (AngII)-induced AHT on L-type Ca(2+) channel-mediated isometric contractions in conduit arteries. AHT was induced in C57Bl6 mice with AngII-filled osmotic mini-pumps (4 weeks). Normotensive mice treated with saline-filled osmotic mini-pumps were used for comparison. Voltage-dependent contractions mediated by L-type Ca(2+) channels were studied in vaso-reactive studies in vitro in isolated aortic and femoral arteries by using extracellular K(+) concentration-response (KDR) experiments. In aortic segments, AngII-induced AHT significantly sensitized isometric contractions induced by elevated extracellular K(+) and depolarization. This sensitization was partly prevented by normalizing blood pressure with hydralazine, suggesting that it was caused by AHT rather than by direct AngII effects on aortic smooth muscle cells. The EC50 for extracellular K(+) obtained in vitro correlated significantly with the rise in arterial blood pressure induced by AngII in vivo. The AHT-induced sensitization persisted when aortic segments were exposed to levcromakalim or to inhibitors of basal nitric oxide release. Consistent with these observations, AngII-treatment also sensitized the vaso-relaxing effects of the L-type Ca(2+) channel blocker diltiazem during K(+)-induced contractions. Unlike aorta, AngII-treatment desensitized the isometric contractions to depolarization in femoral arteries pointing to vascular bed specific responses of arteries to hypertension. AHT affects the voltage-dependent L-type Ca(2+) channel-mediated contraction of conduit arteries. This effect may contribute to the decreased vascular compliance in AHT and explain the efficacy of Ca(2+) channel blockers to reduce vascular stiffness and central blood pressure in AHT.
Magnetized Target Fusion - Field Reversed Configuration Formation and Injection (MTF-FRC)
2009-11-06
from accidental breakage and personnel from injury in that event. The pumps for the vacuum system included a Varian dry scroll pump that was...a dry scroll (oil-free) mechanical pump could be used, as mTorr pressures would be sufficient for the vacuum switch voltage hold-off and operation...56 FIGURE 46. ROUGHING PUMP AND VACUUM -GAUGE CONTROLLERS BENEATH THETA COIL CABLE HEADER
Use of a wire extender during neuroprotected vertebral artery angioplasty and stenting.
Lesley, Walter S; Kumar, Ravi; Rangaswamy, Rajesh
2010-09-01
The off-label use of an extender wire during vertebral artery stenting and angioplasty with or with neuroprotection has not been previously reported. Retrospective, single-patient, technical report. After monorail balloon angioplasty was performed on a proximal left vertebral artery stenosis, the 190 cm long Accunet neuroprotection filter device was not long enough for delivery of an over-the-wire stent. After mating a 145 cm long, 0.014 inch extension wire to the filter device, a balloon-mounted Liberté stent was implanted with good angiographic and clinical results. The off-label use of an extender wire permits successful over-the-wire stenting on a monorail neuroprotection device for vertebral artery endosurgery.
Chi, Li-Qun; Zhang, Jian-Qun; Kong, Qing-Yu; Xiao, Wei; Liang, Lin; Chen, Xin-Liang
2015-01-01
Background: It is still a challenge for the cardiac surgeons to achieve adequate revascularization for diffused coronary artery disease (CAD). Coronary endarterectomy (CE) offers an alternative choice of coronary artery reconstruction and revascularization. In this study, short-term result of CE combined with coronary artery bypass graft (CABG) was discussed in the treatment for the diffused CAD. Methods: From January 2012 to April 2014, 221 cases of CABG were performed by the same surgeon in our unit. Among these cases, 38 cases of CE + CABG were performed, which was about 17.2% (38/221) of the cohort. All these patients were divided into two groups: CE + CABG group (Group A) and CABG alone group (Group B). All clinical data were compared between the two groups, and postoperative complications and in-hospital mortality were analyzed. The categorical and continuous variables were analyzed by Chi-square test and Student's t-test respectively. Results: Diabetes mellitus, hypertension, hyperlipidemia, and peripheral vascular disease were more common in group A. In this cohort, a total of 50 vessels were endarterectomized. Among them, CE was performed on left anterior descending artery in 11 cases, on right coronary artery in 29 cases, on diagonal artery in 3 cases, on intermediate artery in 2 cases, on obtuse marginal artery in 5 cases. There was no hospital mortality in both groups. The intro-aortic balloon pump was required in 3 cases in Group A (3/38), which was more often than that in Group B (3/183). At the time of follow-up, coronary computed tomography angiogram showed all the grafts with CE were patent (50/50). There is no cardio-related mortality in both groups. All these patients were free from coronary re-intervention. Conclusions: Coronary endarterectomy + CABG can offer satisfactory result for patients with diffused CAD in a short-term after the operation. PMID:26021501
Coronary revascularization in patients with liver cirrhosis.
Marui, Akira; Kimura, Takeshi; Tanaka, Shiro; Miwa, Senri; Yamazaki, Kazuhiro; Minakata, Kenji; Nakata, Tomohiro; Ikeda, Tadashi; Furukawa, Yutaka; Kita, Toru; Sakata, Ryuzo
2011-05-01
Liver cirrhosis is a major risk factor for cardiac surgery using cardiopulmonary bypass. However, percutaneous coronary intervention (PCI) or off-pump coronary artery bypass graft surgery (OPCABG) may be a less invasive alternative strategy. Among the 9,877 patients undergoing first PCI or CABG enrolled in the CREDO-Kyoto Registry (a registry of first-time PCI and CABG patients in Japan), 332 patients diagnosed with liver cirrhosis were entered into the study (age 67.1±9.4 years; 246 male). Liver cirrhosis was diagnosed by liver biopsy or signs of portal hypertension with characteristic morphologic liver and spleen changes. A total of 233 patients received PCI, 58 conventional on-pump CABG (CCABG), and 41 OPCABG. Median follow-up was 3.3 years. The PCI group included less complex coronary lesions such as triple vessel and left main disease (p<0.01 each). Propensity score adjusted in-hospital mortality after CCABG or OPCABG was higher than that after PCI; however, the differences were not significant (odds ratio [95% confidence interval]: 6.84 [0.52 to 90.8], p=0.14 for CCABG versus PCI; and 1.86 [0.08 to 45.8], p=0.71 for OPCABG versus PCI). Adjusted overall mortality after CCABG or CABG was lower than that after PCI, but the differences were not significant (0.66 [0.31 to 1.40], p=0.28; and 0.64 [0.28 to 1.49], p=0.31, respectively). Approximately two thirds of patients died of noncardiovascular morbidities (malignancies, including hepatocarcinoma, or hepatic decompression). Because overall noncardiovascular mortality is high among patients with liver cirrhosis, complete revascularization may not be associated with better survival outcomes. Further study is warranted to determine the impact of a coronary revascularization strategy for liver cirrhosis patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Effect of Body Mass Index on Postoperative Transfusions and 24-Hour Chest-Tube Output
Nolan, Heather R.; Ramaiah, Chandrashekhar
2011-01-01
An increasing obese population in the United States focuses attention on the effect of obesity on surgical outcomes. Our objective was to see if obesity, determined by body mass index (BMI), contributed to bleeding in coronary artery bypass graft (CABG) surgery as measured by intraoperative and postoperative packed red blood cell transfusion frequency and amount and 24-hour chest-tube output. A retrospective chart review examined 150 subjects undergoing single-surgeon off-pump or on-pump CABG surgery between September 2006 and April 2009. BMI groups included normal-weight (BMI <25), overweight (BMI 25 to 29), and obese (BMI ≥30). Analyses used a chi-square test to determine variances in number of transfusions, and ANOVA for transfusion amount and 24-hour chest-tube amount. The percentage of subjects receiving intraoperative transfusions varied significantly by BMI group (p = 0.022). The percentage of subjects receiving transfusions in the 72-hour postoperative period showed a decreasing linear trend based on BMI group (p = 0.054). The percentage of subjects receiving transfusions in the combined intraoperative or 72-hour postoperative period showed a decreasing linear trend based on BMI group (p = 0.054). The transfusion amount during the 72-hour postoperative period varied significantly between BMI groups (p = 0.021), and the test for a linear decrease across groups was significant (p = 0.020). Twenty-four hour chest-tube output showed variation across all three BMI categories (p = 0.018) with chest-tube output decreasing with increasing obesity in a linear fashion (p = 0.006). Transfusion rate and amount indicate total blood loss is decreased in the obese, and chest-tube output findings give a direct measurable indicator of blood loss from the surgical site indicating increasing BMI is linearly correlated with decreasing postoperative bleeding. PMID:22654469
Kitagawa, Noriyuki; Ushigome, Emi; Matsumoto, Shinobu; Oyabu, Chikako; Ushigome, Hidetaka; Yokota, Isao; Asano, Mai; Tanaka, Muhei; Yamazaki, Masahiro; Fukui, Michiaki
2018-03-01
This cross-sectional multicenter study was designed to evaluate the threshold value of home pulse pressure (PP) and home systolic blood pressure (SBP) predicting the arterial stiffness in 876 patients with type 2 diabetes. We measured the area under the receiver-operating characteristic curve (AUC) and estimated the ability of home PP to identify arterial stiffness using Youden-Index defined cut-off point. The arterial stiffness was measured using the brachial-ankle pulse wave velocity (baPWV). AUC for arterial stiffness in morning PP was significantly greater than that in morning SBP (P < .001). AUC for arterial stiffness in evening PP was also significantly greater than that in evening SBP (P < .001). The optimal cut-off points for morning PP and evening PP, which predicted arterial stiffness, were 54.6 and 56.9 mm Hg, respectively. Our findings indicate that we should pay more attention to increased home PP in patients with type 2 diabetes. ©2018 Wiley Periodicals, Inc.
Sritippayawan, S; Deerojanawong, J; Prapphal, N
2000-10-01
To determine the correlation between clinical score (based on respiratory rate, chest wall retractions, air entry, wheezing, consciousness and audible wheezing) and arterial oxygen saturation (SaO2: measured by pulse oximetry) as well as the most appropriate total score for predicting hypoxemia (SaO2 < or = 95%) in children diagnosed to have wheezing associated respiratory illness (WARI). 70 children (1 month-5 years old) hospitalized in the Department of Pediatrics, Chulalongkorn Hospital with the diagnosis of WARI from January 1, 1996 to December 31, 1996 were studied. Half of them were diagnosed to have acute lower respiratory tract infection (LRI) with wheezing while the remainder had reactive airway disease (RAD). Cross sectional, analytical study. In each group of patients, the clinical score and SaO2 were assessed by the same pediatrician throughout the study. The correlation between the clinical signs and SaO2 as well as the cut off point of total score for predicting hypoxemia were analyzed. The sensitivity, specificity and accuracy of that total score in predicting hypoxemia were also calculated. In both groups of patients (acute LRI with wheezing and RAD group), the clinical signs correlated with SaO2 were wheezing (rs = -0.67 and -0.47 respectively) and chest wall retractions (rs = -0.57 and -0.59 respectively). Total score was also correlated with SaO2 (rs = -0.68 and -0.5 respectively). The cut off point of total score in predicting hypoxemia was 4 providing 80 per cent sensitivity in both groups with accuracy 74.3 per cent and 80 per cent respectively. This clinical score may be used to assess the severity of hypoxemia in WARI patients. Wheezing, chest wall retractions and total score correlated well with SaO2. The total score > 4 was most appropriate in predicting hypoxemia in both children with RAD and wheezing associated with LRI.
Giant narrowband twin-beam generation along the pump-energy propagation direction
NASA Astrophysics Data System (ADS)
Pérez, Angela M.; Spasibko, Kirill Yu; Sharapova, Polina R.; Tikhonova, Olga V.; Leuchs, Gerd; Chekhova, Maria V.
2015-07-01
Walk-off effects, originating from the difference between the group and phase velocities, limit the efficiency of nonlinear optical interactions. While transverse walk-off can be eliminated by proper medium engineering, longitudinal walk-off is harder to avoid. In particular, ultrafast twin-beam generation via pulsed parametric down-conversion and four-wave mixing is only possible in short crystals or fibres. Here we show that in high-gain parametric down-conversion, one can overcome the destructive role of both effects and even turn them into useful tools for shaping the emission. In our experiment, one of the twin beams is emitted along the pump Poynting vector or its group velocity matches that of the pump. The result is markedly enhanced generation of both twin beams, with the simultaneous narrowing of angular and frequency spectrum. The effect will enable efficient generation of ultrafast twin photons and beams in cavities, waveguides and whispering-gallery mode resonators.
Shen, Yijie; Meng, Yuan; Fu, Xing; Gong, Mali
2018-01-15
A dual-off-axis pumping scheme is presented to generate wavelength-tunable high-order Hermite-Gaussian (HG) modes in Yb:CaGdAlO 4 lasers. The mode and wavelength can be actively controlled by the off-axis displacements and pump power. The purities of the output HG modes are quantified by intensity distributions and the measured M 2 values. The highest order reaches m=15 for stable HG m,0 mode, and wavelength-tunable width is about 10 nm. Moreover, through externally converting the HG m,0 modes, the vortex beams carrying orbital angular momentum (OAM) with a large OAM-tunable range from ±1ℏ to ±15ℏ are produced. This work is effective for largely scaling the spectral and OAM tunable ranges of optical vortex beams.
Study of a heat rejection system using capillary pumping
NASA Technical Reports Server (NTRS)
Neal, L. G.; Wanous, D. J.; Clausen, O. W.
1971-01-01
Results of an analytical study investigating the application of capillary pumping to the heat rejection loop of an advanced Rankine cycle power conversion system are presented. The feasibility of the concept of capillary pumping as an alternate to electromagnetic pumping is analytically demonstrated. Capillary pumping is shown to provide a potential for weight and electrical power saving and reliability through the use of redundant systems. A screen wick pump design with arterial feed lines was analytically developed. Advantages of this design are high thermodynamic and hydrodynamic efficiency, which provide a lightweight easily packaged system. Operational problems were identified which must be solved for successful application of capillary pumping. The most important are the development of start up and shutdown procedures, and development of a means of keeping noncondensibles from the system and of earth-bound testing procedures.
Effects of intra-aortic counterpulsation on aortic wall energetics and damping: in vivo experiments.
Fischer, Edmundo I Cabrera; Bia, Daniel; Camus, Juan M; Zócalo, Yanina; de Forteza, Eduardo; Armentano, Ricardo L
2008-01-01
Intra-aortic balloon pumping (IABP) could modify the arterial biomechanics; however, its effects on arterial wall properties have not been fully explored. This dynamical study was designed to characterize the pressure-dependent and smooth muscle-dependent effects of IABP on aortic wall energetics in an in vivo animal model. Intra-aortic balloon pumping (1:2) was performed in six anesthetized sheep in which aortic pressure and diameter signals were measured in basal, augmented (during balloon inflation), and assisted (postaugmented) beats. Energy dissipation values in augmented and assisted beats were significantly higher than those observed in basal state (p < 0.05). Assisted beats showed a significant increase of wall damping with respect to basal and augmented beats (p < 0.05). Intra-aortic balloon pumping resulted in a significant increase of pulse wave velocity (p < 0.05) in augmented beats with respect to basal state (6.3 +/- 0.8 vs. 5.2 +/- 0.5 m x s(-1)); whereas values observed in assisted beats were significantly (p < 0.05) lower than those observed in augmented beats (4.9 +/- 0.5 vs. 6.3 +/- 0.8 m x s(-1)). Our findings show that IABP determined the pressure and smooth muscle-dependent changes in arterial wall energetics and damping properties in this animal model.
Najafi, H; Veeragandham, R
1997-08-01
On three occasions during operations for aortic aneurysm involving the ascending aorta it was noted that upon the release of the aortic clamp the grafted segment remained collapsed, indicating very little or no flow reaching the lumen of the reconstructed aorta. This was promptly and successfully remedied in 2 patients by perfusing the graft directly with a pediatric arterial catheter attached to a pump head while the femoral arterial line maintained systemic arterial inflow. This simple, safe, and highly effective technique adds to the surgeon's repertoire to manage yet another intriguing intraoperative development during thoracic aortic operations.
Cross, B A; Grant, B J; Guz, A; Jones, P W; Semple, S J; Stidwill, R P
1979-01-01
1. The hypothesis that respiratory oscillations of arterial blood gas composition influence ventilation has been examined. 2. Phrenic motoneurone output recorded in the C5 root of the left phrenic nerve and the respiratory oscillations of arterial pH in the right common carotid artery were measured in vagotomized anaesthetized dogs which had been paralysed and artificially ventilated. 3. The effect of a change in tidal volume for one or two breaths on phrenic motoneurone output was measured with the inspiratory pump set at a constant frequency similar to, and in phase with, the animal's own respiratory frequency. A reduction of tidal volume to zero or an increase by 30% led to a corresponding change of mean carotid artery pH level. The changes of carotid artery pH resulted in a change of phrenic motoneurone output, predominantly of expiratory time (Te) but to a lesser extent of inspiratory time (T1) and also peak amplitude of 'integrated' phrenic motoneurone output (Phr). Denervation of the carotid bifurcation blocked this response. 4. The onset of movement of the inspiratory pump was triggered by the onset of phrenic motoneurone output. When a time delay was interposed between them, the phase relationship between respiratory oscillations of arterial pH and phrenic motoneurone output altered. The dominant effect was to alter Te; smaller and less consistent changes of Phr and T1 were observed. 5. When the inspiratory pump was maintained at a constant frequency but independent of and slightly different from the animal's own respiratory frequency (as judged by phrenic motoneurone output), the phase relationship between phrenic motoneurone output and the respiratory oscillations of pH changed breath by breath over a sequence of 100-200 breaths, without change of the mean level of arterial blood gas composition. Te varied by up to 30% about its mean value depending on the phase relationship. Ti and Phr were also dependent on the phase relationship but varied to a lesser extent. The changes were comparable to the results obtained in paragraph 4. 6. It was concluded that phrenic motoneurone output is dependent in part on its relationship to the respiratory oscillations of arterial blood gas composition. 7. Information concerning a transient ventilatory disturbance is stored in the arterial blood in the form of an altered pattern of the respiratory oscillations of blood gas composition; this in turn can change breathing by an effect on the carotid bodies. Images Fig. 3 PMID:38333
Choi, Dae Sik; Rao, B Jayachander; Kim, Doyeon; Shim, Sang-Hee; Rhee, Hanju; Cho, Minhaeng
2018-06-14
Coherent Raman scattering spectroscopy and microscopy are useful methods for studying the chemical and biological structures of molecules with Raman-active modes. In particular, coherent anti-Stokes Raman scattering (CARS) microscopy, which is a label-free method capable of imaging structures by displaying the vibrational contrast of the molecules, has been widely used. However, the lack of a technique for switching-off the CARS signal has prevented the development of the super-resolution Raman imaging method. Here, we demonstrate that a selective suppression of the CARS signal is possible by using a three-beam double stimulated Raman scattering (SRS) scheme; the three beams are the pump, Stokes, and depletion lights in order of frequency. Both pump-Stokes and pump-depletion beam pairs can generate SRS processes by tuning their beat frequencies to match two different vibrational modes, then two CARS signals induced by pump-Stokes-pump and pump-depletion-pump interactions can be generated, where the two CARS signals are coupled with each other because they both involve interactions with the common pump beam. Herein, we show that as the intensity of the depletion beam is increased, one can selectively suppress the pump-Stokes-pump CARS signal because the pump-depletion SRS depletes the pump photons. A detailed theoretical description of the coupled differential equations for the three incident fields and the generated CARS signal fields is presented. Taking benzene as a molecular system, we obtained a maximum CARS suppression efficiency of about 97% with our experimental scheme, where the ring breathing mode of the benzene is associated with pump-Stokes-pump CARS, while the C-H stretching mode is associated with the competing pump-depletion SRS process. We anticipate that this selective switching-off scheme will be of use in developing super-resolution label-free CARS microscopy.
77 FR 54793 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-06
... was prompted by fuel system reviews conducted by the manufacturer. This AD requires adding design... system must shut off each pump no later than 60 seconds after the fuel tank is emptied. Noting that the... paragraph (g)(2): ``The pump shutoff system design must preclude undetected running of a fuel pump in an...
Predictors of early graft failure after coronary artery bypass grafting for chronic total occlusion.
Oshima, Hideki; Tokuda, Yoshiyuki; Araki, Yoshimori; Ishii, Hideki; Murohara, Toyoaki; Ozaki, Yukio; Usui, Akihiko
2016-07-01
Little is known regarding the transit-time flow measurement (TTFM) variables in grafts anastomosed to chronically totally occluded vessels (CTOs). We aimed to establish the TTFM cut-off values for detecting graft failure in bypass grafts anastomosed to chronically totally occluded arteries and clarify the relationship between early graft failure and the grade of collateral circulation/regional wall motion of the CTO territory. Among 491 patients who underwent isolated coronary artery bypass grafting (CABG) from 2009 to 2015, 196 cases with CTOs underwent postoperative coronary angiography within 1 month after CABG. Two hundred and forty-one CTOs in all patients were examined. Thirty-two CTOs (13%) were not bypassed and 214 conduits were anastomosed to CTOs and underwent intraoperative TTFM. Arterial conduits and saphenous vein grafts (SVGs) were used in 102 and 112 cases, respectively. Among the arterial conduit procedures that were performed, 78 involved the left internal thoracic artery (LITA), 10 involved the right internal thoracic artery (RITA) and 14 involved the right gastroepiploic artery (rGEA). Any graft showing Fitzgibbon type B or O lesions on angiography was considered to be a failing graft. The insufficiency rates for LITA, RITA, rGEA and SVG procedures were 5.1, 10, 14.3 and 7.1%, respectively. The TTFM variables recorded in failing grafts had a significantly lower mean flow (Qmean) and higher pulsatility index (PI) compared with patent grafts. Furthermore, akinetic or dyskinetic wall motion in the territory of bypassed CTOs was observed at a significantly higher rate in failing grafts. A multivariable regression analysis and receiver operating characteristic analysis revealed good predictors of early graft failure as follows: a Qmean value of < 11.5 ml/min for arterial conduits, a PI value of >5.85 and akinetic/dyskinetic wall motion in the CTO territory for SVGs. The Rentrop collateral grade was not associated with early graft failure. The Qmean value and PI value by the TTFM are useful to detect early graft failure in conduits anastomosed to CTOs. The collateral grade is not associated with graft failure; however, bypass grafting to CTOs with akinetic/dyskinetic wall motion should be carefully considered. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
A postscript to Circulation of the blood: men and ideas.
Riley, R L
1982-10-01
Since 1964, when Fishman and Richards published Circulation of the Blood: Men and Ideas, Guyton's model of the circulation, in which mean circulatory pressure serves as the upstream pressure for venous return, has been extended, and the concept of vascular smooth muscle tone acting like the pressure surrounding a Starling resistor has been postulated. According to this scheme, the positive zero flow intercepts of rapidly determined arterial pressure-flow curves are the effective downstream pressures for arterial flow to different tissues. The arterioles, like Starling resistors, determine the downstream pressures and are followed by abrupt pressure drops, or "waterfalls." Capillary pressures are closely linked to those of the venules into which they flow. Capillary-venular pressures are the upstream pressures for venous return. In exercising muscles, reduced arteriolar tone lowers arteriolar pressure and increases arterial flow. This, in turn, raises capillary-venular pressure and increases venous flow. The arteriolar-capillary waterfall is decreased or eliminated. Total blood flow is increased by diversion of blood from tissues with slow venous drainage to muscles with fast venous drainage (low resistance X compliance). The heart pumps away the increased venous return by shifting to a new ventricular function curve.
1996-07-24
to fuel tank 27 aboard 23 test torpedo 26. Pressure switch 19B operates to close solenoid 24 valve 22A and concurrently open solenoid valve 22D...leading to a pump explosion. The boost pump 4 is driven by its 11 motor 14B and positive displacement pump 1 by its respective 12 motor 14A. Pressure ... switch 19A monitors the head pressure 13 created by the boost pump 4 and it will shut off the motor 14A of 14 the positive displacement pump 1 if
Barkhordari, Khosro; Yousefshahi, Fardin; Khajavi, Mohammad Reza; Karimi, Abbasali
2012-06-01
Compartment syndrome is a rare, devastating complication of coronary artery bypass grafting (CABG) and intra-aortic balloon pump (IABP). Prompt diagnosis is based on symptoms and signs and is paramount for limb rescue. This report describes a CABG patient with IABP in whom receiving continuous analgesia-sedation obscured the symptoms of compartment syndrome.
Lim, Ki Moo; Lee, Jeong Sang; Gyeong, Min-Soo; Choi, Jae-Sung; Choi, Seong Wook
2013-01-01
To quantify the reduction in workload during intra-aortic balloon pump (IABP) therapy, indirect parameters are used, such as the mean arterial pressure during diastole, product of heart rate and peak systolic pressure, and pressure-volume area. Therefore, we investigated the cardiac energy consumption during IABP therapy using a cardiac electromechanics model. We incorporated an IABP function into a previously developed electromechanical model of the ventricle with a lumped model of the circulatory system and investigated the cardiac energy consumption at different IABP inflation volumes. When the IABP was used at inflation level 5, the cardiac output and stroke volume increased 11%, the ejection fraction increased 21%, the stroke work decreased 1%, the mean arterial pressure increased 10%, and the ATP consumption decreased 12%. These results show that although the ATP consumption is decreased significantly, stroke work is decreased only slightly, which indicates that the IABP helps the failed ventricle to pump blood efficiently. PMID:23341718
Lim, Ki Moo; Lee, Jeong Sang; Gyeong, Min-Soo; Choi, Jae-Sung; Choi, Seong Wook; Shim, Eun Bo
2013-01-01
To quantify the reduction in workload during intra-aortic balloon pump (IABP) therapy, indirect parameters are used, such as the mean arterial pressure during diastole, product of heart rate and peak systolic pressure, and pressure-volume area. Therefore, we investigated the cardiac energy consumption during IABP therapy using a cardiac electromechanics model. We incorporated an IABP function into a previously developed electromechanical model of the ventricle with a lumped model of the circulatory system and investigated the cardiac energy consumption at different IABP inflation volumes. When the IABP was used at inflation level 5, the cardiac output and stroke volume increased 11%, the ejection fraction increased 21%, the stroke work decreased 1%, the mean arterial pressure increased 10%, and the ATP consumption decreased 12%. These results show that although the ATP consumption is decreased significantly, stroke work is decreased only slightly, which indicates that the IABP helps the failed ventricle to pump blood efficiently.
Computer Simulations of Coronary Blood Flow Through a Constriction
2014-03-01
interventional procedures (e.g., stent deployment). Building off previous models that have been partially validated with experimental data, this thesis... stent deployment). Building off previous models that have been partially validated with experimental data, this thesis continues to develop the...the artery and increase blood flow. Generally a stent , or a mesh wire tube, is permanently inserted in order to scaffold open the artery wall
Shen, J Q; Ji, Q; Ding, W J; Xia, L M; Wei, L; Wang, C S
2018-03-13
Objective: To evaluate in-hospital and mid-term outcomes of sequential versus separate grafting of in situ skeletonized left internal mammary artery (LIMA) to the left coronary system in a single-center, propensity-matched study. Methods: After propensity score matching, 120 pairs of patients undergoing first, scheduled, isolated coronary artery bypass grafting (CABG) with in situ skeletonized LIMA grafting to the left anterior descending artery (LAD) territory were entered into a sequential group (sequential grafting of LIMA to the diagonal artery and then to the LAD) or a control group (separate grafting of LIMA to the LAD). The in-hospital and follow-up clinical outcomes and follow-up LIMA graft patency were compared. Results: The two propensity score-matched groups had similar in-hospital and follow-up clinical outcomes. The number of bypass conduits ranged from 3 to 6 (with a mean of 3.5), and 91.3%(219/240)of the included patients received off-pump CABG surgery. No significant differences were found between the two propensity score-matched groups in the in-hospital outcomes, including in-hospital death and the incidence of complications associated with CABG (prolonged ventilation, peroperative stroke, re-operation before discharge, and deep sternal wound infection). During follow-up, 9 patients (4 patients from the sequential group and 5 patients from the control group) died, and the all-cause mortality rate was 3.9%. No significant difference was found in the all-cause mortality rate between the 2 groups[3.4% (4/116) vs 4.3% (5/115), P =0.748]. During follow-up period, 99.1% (115/116) patency for the diagonal site and 98.3% (114/116) for the LAD site were determined by coronary computed tomographic angiography after sequential LIMA grafting, both of which were similar with graft patency of separate grafting of in situ skeletonized LIMA to the LAD. Conclusions: Revascularization of the left coronary system using a skeletonized LIMA resulted in excellent in-hospital and mid-term clinical outcomes and graft patency using sequential grafting.
Fukui, Toshihiro; Tabata, Minoru; Morita, Satoshi; Takanashi, Shuichiro
2013-06-01
The aim of the present study was to determine the early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome and stable angina pectoris. From September 2004 to September 2011, 382 patients with acute coronary syndrome (unstable angina pectoris and non-ST-segment elevation myocardial infarction) and 851 patients with stable angina pectoris underwent first-time isolated coronary artery bypass grafting at our institute. The early and long-term outcomes were compared between the 2 groups. Patients with acute coronary syndrome were older, were more likely to be women, had a smaller body surface area, and were more likely to have left main coronary artery disease. In both groups, bilateral internal thoracic artery grafts were used in approximately 89% of the patients, and off-pump techniques in approximately 97% of the patients. The acute coronary syndrome group had a greater operative death rate (2.6% vs 0.1%) and a greater incidence of low output syndrome (3.1% vs 1.2%) and hemodialysis requirement (2.9% vs 1.1%). Multivariate regression analysis demonstrated that age, acute coronary syndrome, lower ejection fraction, and higher creatinine level before surgery were independent predictors of operative death. However, among the hospital survivors, no differences were seen in freedom from all death (85.4% ± 2.5% vs 87.7% ± 2.0%), cardiac death (97.4% ± 0.9% vs 96.5% ± 0.9%), or major adverse cardiac and cerebrovascular events (78.0% ± 2.9% vs 78.1% ± 2.3%) at 7 years between the patients with acute coronary syndrome and stable angina pectoris. Although acute coronary syndrome is an independent predictor of early mortality in patients undergoing coronary artery bypass grafting, the long-term outcomes after surgery were similar between patients with acute coronary syndrome and stable angina pectoris who survived the early postoperative period. Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
2011-01-01
Background Negative pressure wound therapy (NPWT) has remarkable effects on the healing of poststernotomy mediastinitis. Foam is presently the material of choice for NPWT in this indication. There is now increasing interest in using gauze, as this has proven successful in the treatment of peripheral wounds. It is important to determine the effects of NPWT using gauze on heart pumping function before it can be used for deep sternotomy wounds. The aim was to examine the effects of NPWT when using gauze and foam on the heart pumping function during the treatment of a sternotomy wound. Methods Eight pigs underwent median sternotomy followed by NPWT at -40, -70, -120 and -160 mmHg, using foam or gauze. The heart frequency, cardiac output, mean systemic arterial pressure, mean pulmonary artery pressure, central venous pressure and left atrial pressure were recorded. Results Cardiac output was not affected by NPWT using gauze or foam. Heart frequency decreased during NPWT when using foam, but not gauze. Treatment with foam also lowered the central venous pressure and the left atrial pressure, while gauze had no such effects. Mean systemic arterial pressure, mean pulmonary artery pressure and systemic vascular resistance were not affected by NPWT. Similar haemodynamic effects were observed at all levels of negative pressure studied. Conclusions NPWT using foam results in decreased heart frequency and lower right and left atrial filling pressures. The use of gauze in NPWT did not affect the haemodynamic parameters studied. Gauze may thus provide an alternative to foam for NPWT of sternotomy wounds. PMID:21232105
Selective Heart, Brain and Body Perfusion in Open Aortic Arch Replacement.
Maier, Sven; Kari, Fabian; Rylski, Bartosz; Siepe, Matthias; Benk, Christoph; Beyersdorf, Friedhelm
2016-09-01
Open aortic arch replacement is a complex and challenging procedure, especially in post dissection aneurysms and in redo procedures after previous surgery of the ascending aorta or aortic root. We report our experience with the simultaneous selective perfusion of heart, brain, and remaining body to ensure optimal perfusion and to minimize perfusion-related risks during these procedures. We used a specially configured heart-lung machine with a centrifugal pump as arterial pump and an additional roller pump for the selective cerebral perfusion. Initial arterial cannulation is achieved via femoral artery or right axillary artery. After lower body circulatory arrest and selective antegrade cerebral perfusion for the distal arch anastomosis, we started selective lower body perfusion simultaneously to the selective antegrade cerebral perfusion and heart perfusion. Eighteen patients were successfully treated with this perfusion strategy from October 2012 to November 2015. No complications related to the heart-lung machine and the cannulation occurred during the procedures. Mean cardiopulmonary bypass time was 239 ± 33 minutes, the simultaneous selective perfusion of brain, heart, and remaining body lasted 55 ± 23 minutes. One patient suffered temporary neurological deficit that resolved completely during intensive care unit stay. No patient experienced a permanent neurological deficit or end-organ dysfunction. These high-risk procedures require a concept with a special setup of the heart-lung machine. Our perfusion strategy for aortic arch replacement ensures a selective perfusion of heart, brain, and lower body during this complex procedure and we observed excellent outcomes in this small series. This perfusion strategy is also applicable for redo procedures.
Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf
2012-08-01
Transapical (TA) aortic valve implantation (AVI) has evolved as an alternative procedure for high-risk patients. We evaluated the second-generation SAPIEN XT™ prosthesis in a prospective multicentre clinical trial. A total of 150 patients (age: 81.6 ± 5.8 years; 40.7% female) were included. Prosthetic valves (diameter: 23 mm (n = 36), 26 mm (n = 57) and 29 mm (n = 57)) were implanted. The ASCENDRA-II™ modified delivery system was used in the smaller sizes. Mean logistic EuroSCORE was 24.3 ± 7.0%, and mean STS score 7.5 ± 4.4%. All patients gave written informed consent. Off-pump AVI was performed using femoral arterial and venous access wires as a safety net. All but two patients received TA-AVI, as planned. The 29-mm valve showed similar function as the values of two other diameters did. Three patients (2%) required temporary cardiopulmonary bypass support. Postoperative complications included renal failure requiring long-term dialysis in four, bleeding requiring rethoracotomy in four, respiratory complication requiring reintubation in eight and sepsis in four patients, respectively. Thirty-day mortality was 13 (8.7%) for the total cohort and 2/57 (3.5%) for patients receiving the 29-mm valve, respectively. Echocardiography at discharge showed none or trivial aortic incompetence (AI) in 71% and mild-AI in 22% of the patients. Post-implantation AI was predominantly paravalvular and ≥ 2+ in 7% of patients. One patient required reoperation for AI within 30 days. The PREVAIL TA multicentre trial demonstrates good functionality and good outcomes for TA-AVI, using the SAPIEN XT™ prosthesis and its second-generation ASCENDRA-II™ delivery system, as well successful introduction of the 29-mm SAPIEN XT™ valve for the benefit of high-risk elderly patients.
Wang, Shigang; Kunselman, Allen R; Ündar, Akif
2017-01-01
The objective of this study was to evaluate the hemodynamic performance and energy transmission of flexible arterial tubing as the arterial line in a simulated pediatric pulsatile extracorporeal life support (ECLS) system. The ECLS circuit consisted of a Medos Deltastream DP3 diagonal pump head, Medos Hilite 2400 LT oxygenator, Biomedicus arterial/venous cannula (10 Fr/14 Fr), 3 feet of polyvinyl chloride (PVC) arterial tubing or latex rubber arterial tubing, primed with lactated Ringer's solution and packed red blood cells (hematocrit 40%). Trials were conducted at flow rates of 300 to 1200 mL/min (300 mL/min increments) under nonpulsatile and pulsatile modes at 36°C using either PVC arterial tubing (PVC group) or latex rubber tubing (Latex group). Real-time pressure and flow data were recorded using a custom-based data acquisition system. Mean pressures and energy equivalent pressures (EEP) were the same under nonpulsatile mode between the two groups. Under pulsatile mode, EEPs were significantly great than mean pressure, especially in the Latex group (P < 0.05). There was no difference between the two groups with regards to pressure drops across ECLS circuit, but pulsatile flow created more pressure drops than nonpulsatile flow (P < 0.05). Surplus hemodynamic energy (SHE) levels were always higher in the Latex group than in the PVC group at all sites. Although total hemodynamic energy (THE) losses were higher under pulsatile mode compared to nonpulsatile mode, more THE was delivered to the pseudopatient, particularly in the Latex group (P < 0.05). The results showed that the flexible arterial tubing retained more hemodynamic energy passing through it under pulsatile mode while mean pressures and pressure drops across the ECLS circuit were similar between PVC and latex rubber arterial tubing. Further studies are warranted to verify our findings. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Ye, Qiang; Hu, Jing; Cheng, Ping; Ma, Zhiqi
2015-11-01
Trade-off between shunt current loss and pumping loss is a major challenge in the design of the electrolyte piping network in a flow battery system. It is generally recognized that longer and thinner ducts are beneficial to reduce shunt current but detrimental to minimize pumping power. Base on the developed analog circuit model and the flow network model, we make case studies of multi-stack vanadium flow battery piping systems and demonstrate that both shunt current and electrolyte flow resistance can be simultaneously minimized by using longer and thicker ducts in the piping network. However, extremely long and/or thick ducts lead to a bulky system and may be prohibited by the stack structure. Accordingly, the intrinsic design trade-off is between system efficiency and compactness. Since multi-stack configurations bring both flexibility and complexity to the design process, we perform systematic comparisons among representative piping system designs to illustrate the complicated trade-offs among numerous parameters including stack number, intra-stack channel resistance and inter-stack pipe resistance. As the final design depends on various technical and economical requirements, this paper aims to provide guidelines rather than solutions for designers to locate the optimal trade-off points according to their specific cases.
Shin, Eun Kyung; Moon, Won; Park, Seun Ja; Park, Moo In; Kim, Kyu Jong; Lee, Jee Suk; Kwon, Jin Hwan
2009-03-21
Congenital absence of the splenic artery is a very rare condition. To the best of our knowledge, congenital absence of the splenic artery accompanied with absence of the splenic vein has not been reported. We report a case of the absence of the splenic artery and vein in a 61-year-old woman who presented with postprandial epigastric discomfort. Upper gastrointestinal endoscopy showed a dilated, pulsatile vessel in the fundus and duodenal stenosis. An abdominal computed tomography (CT) scan revealed absence of the splenic vein with a tortuously engorged gastroepiploic vein. Three-dimensional CT demonstrated the tortuously dilated left gastric artery and the left gastroepiploic artery with non-visualization of the splenic artery. After administration of a proton pump inhibitor, abdominal symptoms resolved without any recurrence of symptoms during 6 mo of follow-up.
NASA Astrophysics Data System (ADS)
Tsai, Ko-Fan; Chu, Shu-Chun
2018-03-01
This study proposes a complete and unified method for selective excitation of any specified nearly nondiffracting Helmholtz-Gauss (HzG) beam in end-pumped solid-state digital lasers. Four types of the HzG beams: cosine-Gauss beams, Bessel-Gauss beams, Mathieu-Gauss beams, and, in particular, parabolic-Gauss beams are successfully demonstrated to be generated with the proposed methods. To the best of the authors’ knowledge, parabolic-Gauss beams have not yet been directly generated from any kind of laser system. The numerical results of this study show that one can successfully achieve any lasing HzG beams directly from the solid-state digital lasers with only added control of the laser gain transverse position provided by off-axis end pumping. This study also presents a practical digital laser set-up for easily manipulating off-axis pumping in order to achieve the control of the laser gain transverse gain position in digital lasers. The reported results in this study provide advancement of digital lasers in dynamically generating nondiffracting beams. The control of the digital laser cavity gain position creates the possibility of achieving real-time selection of more laser modes in digital lasers, and it is worth further investigation in the future.
How NaCl raises blood pressure: a new paradigm for the pathogenesis of salt-dependent hypertension
Leenen, Frans H. H.; Chen, Ling; Golovina, Vera A.; Hamlyn, John M.; Pallone, Thomas L.; Van Huysse, James W.; Zhang, Jin; Wier, W. Gil
2012-01-01
Excess dietary salt is a major cause of hypertension. Nevertheless, the specific mechanisms by which salt increases arterial constriction and peripheral vascular resistance, and thereby raises blood pressure (BP), are poorly understood. Here we summarize recent evidence that defines specific molecular links between Na+ and the elevated vascular resistance that directly produces high BP. In this new paradigm, high dietary salt raises cerebrospinal fluid [Na+]. This leads, via the Na+-sensing circumventricular organs of the brain, to increased sympathetic nerve activity (SNA), a major trigger of vasoconstriction. Plasma levels of endogenous ouabain (EO), the Na+ pump ligand, also become elevated. Remarkably, high cerebrospinal fluid [Na+]-evoked, locally secreted (hypothalamic) EO participates in a pathway that mediates the sustained increase in SNA. This hypothalamic signaling chain includes aldosterone, epithelial Na+ channels, EO, ouabain-sensitive α2 Na+ pumps, and angiotensin II (ANG II). The EO increases (e.g.) hypothalamic ANG-II type-1 receptor and NADPH oxidase and decreases neuronal nitric oxide synthase protein expression. The aldosterone-epithelial Na+ channel-EO-α2 Na+ pump-ANG-II pathway modulates the activity of brain cardiovascular control centers that regulate the BP set point and induce sustained changes in SNA. In the periphery, the EO secreted by the adrenal cortex directly enhances vasoconstriction via an EO-α2 Na+ pump-Na+/Ca2+ exchanger-Ca2+ signaling pathway. Circulating EO also activates an EO-α2 Na+ pump-Src kinase signaling cascade. This increases the expression of the Na+/Ca2+ exchanger-transient receptor potential cation channel Ca2+ signaling pathway in arterial smooth muscle but decreases the expression of endothelial vasodilator mechanisms. Additionally, EO is a growth factor and may directly participate in the arterial structural remodeling and lumen narrowing that is frequently observed in established hypertension. These several central and peripheral mechanisms are coordinated, in part by EO, to effect and maintain the salt-induced elevation of BP. PMID:22058154
Developments in parallel grafts for aortic arch lesions.
Kolvenbach, Ralf R; Rabin, Asaf; Karmeli, Ron; Alpaslan, Alper; Schwierz, Elizabeth
2016-06-01
Due to the shortage of commercially available off the shelf aortic arch grafts since the last years parallel grafts or chimney grafts have played an increasing role in the treatment of patients with aortic arch lesions. Although there are still issues with type endoleaks and gutters between the chimney graft and the aortic stent-graft remaining. We report our results with the Medtronic thoracic graft in combination with long self-expanding parallel grafts, to ensure an overlapping zone of more than 7 cm between the different grafts. Alternatively, sandwich configurations are used where a direct contact between the parallel graft and the aortic wall is avoided. We have placed a total of 65 parallel grafts into supra-aortic branches. In 21 cases chimney grafts were placed into the carotid artery, in most cases into the left common carotid artery. In 36 cases chimney grafts were placed into left subclavian artery. A maximum number of 4 parallel grafts were placed for total endovascular debranching. In addition, in 8 patients a parallel graft had to be placed into the innominate artery. There was a patency of 69% for all subclavian artery chimney grafts versus 73% for carotid artery parallel grafts. Of note is a stroke rate of 5.2% in all these cases. Only 2 of the patients with an occluded left subclavian artery chimney graft required a bypass procedure for arm claudication or ischemia. We had a primary type I endoleak rate of 28%. In almost 25% secondary interventions were required mainly to treat type I leaks, in those cases where the leak did not resolve spontaneously. The overall mortality rate was 3.5%. The results of parallel graft in the aortic arch are promising, but of major concern is still the high rate of type I endoleaks as well as the neurological complication rate, most probably due to catheter manipulation in patients with severe atherosclerotic arch lesions.
A microprocessor-controlled tracheal insufflation-assisted total liquid ventilation system.
Parker, James Courtney; Sakla, Adel; Donovan, Francis M; Beam, David; Chekuri, Annu; Al-Khatib, Mohammad; Hamm, Charles R; Eyal, Fabien G
2009-09-01
A prototype time cycled, constant volume, closed circuit perfluorocarbon (PFC) total liquid ventilator system is described. The system utilizes microcontroller-driven display and master control boards, gear motor pumps, and three-way solenoid valves to direct flow. A constant tidal volume and functional residual capacity (FRC) are maintained with feedback control using end-expiratory and end-inspiratory stop-flow pressures. The system can also provide a unique continuous perfusion (bias flow, tracheal insufflation) through one lumen of a double-lumen endotracheal catheter to increase washout of dead space liquid. FRC and arterial blood gases were maintained during ventilation with Rimar 101 PFC over 2-3 h in normal piglets and piglets with simulated pulmonary edema induced by instillation of albumin solution. Addition of tracheal insufflation flow significantly improved the blood gases and enhanced clearance of instilled albumin solution during simulated edema.
The cost of open heart surgery in Nigeria.
Falase, Bode; Sanusi, Michael; Majekodunmi, Adetinuwe; Ajose, Ifeoluwa; Idowu, Ariyo; Oke, David
2013-01-01
Open Heart Surgery (OHS) is not commonly practiced in Nigeria and most patients who require OHS are referred abroad. There has recently been a resurgence of interest in establishing OHS services in Nigeria but the cost is unknown. The aim of this study was to determine the direct cost of OHS procedures in Nigeria. The study was performed prospectively from November to December 2011. Three concurrent operations were selected as being representative of the scope of surgery offered at our institution. These procedures were Atrial Septal Defect (ASD) Repair, Off Pump Coronary Artery Bypass Grafting (OPCAB) and Mitral Valve Replacement (MVR). Cost categories contributing to direct costs of OHS (Investigations, Drugs, Perfusion, Theatre, Intensive Care, Honorarium and Hospital Stay) were tracked to determine the total direct cost for the 3 selected OHS procedures. ASD repair cost $ 6,230 (Drugs $600, Intensive Care $410, Investigations $955, Perfusion $1080, Theatre $1360, Honorarium $925, Hospital Stay $900). OPCAB cost $8,430 (Drugs $740, Intensive Care $625, Investigations $3,020, Perfusion $915, Theatre $1305, Honorarium $925, Hospital Stay $900). MVR with a bioprosthetic valve cost $11,200 (Drugs $1200, Intensive Care $500, Investigations $3040, Perfusion $1100, Theatre $3,535, Honorarium $925, Hospital Stay $900). The direct cost of OHS in Nigeria currently ranges between $6,230 and $11,200. These costs compare favorably with the cost of OHS abroad and can serve as a financial incentive to patients, sponsors and stakeholders to have OHS procedures done in Nigeria.
Nonlinear identification of the total baroreflex arc: chronic hypertension model.
Moslehpour, Mohsen; Kawada, Toru; Sunagawa, Kenji; Sugimachi, Masaru; Mukkamala, Ramakrishna
2016-05-01
The total baroreflex arc is the open-loop system relating carotid sinus pressure (CSP) to arterial pressure (AP). Its linear dynamic functioning has been shown to be preserved in spontaneously hypertensive rats (SHR). However, the system is known to exhibit nonlinear dynamic behaviors. The aim of this study was to establish nonlinear dynamic models of the total arc (and its subsystems) in hypertensive rats and to compare these models with previously published models for normotensive rats. Hypertensive rats were studied under anesthesia. The vagal and aortic depressor nerves were sectioned. The carotid sinus regions were isolated and attached to a servo-controlled piston pump. AP and sympathetic nerve activity were measured while CSP was controlled via the pump using Gaussian white noise stimulation. Second-order, nonlinear dynamics models were developed by application of nonparametric system identification to a portion of the measurements. The models of the total arc predicted AP 21-43% better (P < 0.005) than conventional linear dynamic models in response to a new portion of the CSP measurement. The linear and nonlinear terms of these validated models were compared with the corresponding terms of an analogous model for normotensive rats. The nonlinear gains for the hypertensive rats were significantly larger than those for the normotensive rats [-0.38 ± 0.04 (unitless) vs. -0.22 ± 0.03, P < 0.01], whereas the linear gains were similar. Hence, nonlinear dynamic functioning of the sympathetically mediated total arc may enhance baroreflex buffering of AP increases more in SHR than normotensive rats. Copyright © 2016 the American Physiological Society.
Long pulse pumping behavior of a cryopump for the neutral beam injector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakrapani, Ch.; Sharma, S. K.; Chakraborty, A. K.
2007-01-15
This article presents studies on the long term pumping behavior of a cryopump. It is shown that the pumping speed does not deteriorate on a time scale of 4200 s for a gas load of 2.4x10{sup 5} torr l, corresponding to {approx}10{sup 6} ML of hydrogen. It has also been observed that the need for regeneration of the pump is dictated by the safety limits of operation rather than its pumping capability. No sudden boil off of the cryogen takes place during the regeneration phase.
Antman, Yair; Yaron, Lior; Langer, Tomi; Tur, Moshe; Levanon, Nadav; Zadok, Avi
2013-11-15
Dynamic Brillouin gratings (DBGs), inscribed by comodulating two writing pump waves with a perfect Golomb code, are demonstrated and characterized experimentally. Compared with pseudo-random bit sequence (PRBS) modulation of the pump waves, the Golomb code provides lower off-peak reflectivity due to the unique properties of its cyclic autocorrelation function. Golomb-coded DBGs allow the long variable delay of one-time probe waveforms with higher signal-to-noise ratios, and without averaging. As an example, the variable delay of return-to-zero, on-off keyed data at a 1 Gbit/s rate, by as much as 10 ns, is demonstrated successfully. The eye diagram of the reflected waveform remains open, whereas PRBS modulation of the pump waves results in a closed eye. The variable delay of data at 2.5 Gbit/s is reported as well, with a marginally open eye diagram. The experimental results are in good agreement with simulations.
Modeling and design of a high efficiency hybrid heat pump clothes dryer
DOE Office of Scientific and Technical Information (OSTI.GOV)
TeGrotenhuis, Ward; Butterfield, Andrew; Caldwell, Dustin
Computational modeling is used to design a hybrid heat pump clothes dryer capable of saving 50% of the energy used by residential clothes dryers with comparable drying times. The model represents the various stages of a drying cycle from warm-up through constant drying rate and falling drying rate phases and finishing with a cooldown phase. The model is fit to data acquired from a U.S. commercial standard vented electric dryer, and when a hybrid heat pump system is added, the energy factor increases from 3.0 lbs/kWh to 5.7-6.0 lbs/kWh, depending on the increase in blower motor power. The hybrid heatmore » pump system is designed from off-the-shelf components and includes a recuperative heat exchanger, an electric element, and an R-134a vapor compression heat pump. Parametric studies of element power and heating element use show a trade-off between energy savings and cycle time. Results show a step-change in energy savings from heat pump dryers currently marketed in the U.S. based on performance represented by Enery Star from standardized DOE testing.« less
A New Hemodynamic Ex Vivo Model for Medical Devices Assessment.
Maurel, Blandine; Sarraf, Christophe; Bakir, Farid; Chai, Feng; Maton, Mickael; Sobocinski, Jonathan; Hertault, Adrien; Blanchemain, Nicolas; Haulon, Stephan; Lermusiaux, Patrick
2015-11-01
In-stent restenosis (ISR) remains a major public health concern associated with an increased morbidity, mortality, and health-related costs. Drug-eluting stents (DES) have reduced ISR, but generate healing-related issues or hypersensitivity reactions, leading to an increased risk of late acute stent thrombosis. Assessments of new DES are based on animal models or in vitro release systems, which have several limitations. The role of flow and shear stress on endothelial cell and ISR has also been emphasized. The aim of this work was to design and first evaluate an original bioreactor, replicating ex vivo hemodynamic and biological conditions similar to human conditions, to further evaluate new DES. This bioreactor was designed to study up to 6 stented arteries connected in bypass, immersed in a culture box, in which circulated a physiological systolo-diastolic resistive flow. Two centrifugal pumps drove the flow. The main pump generated pulsating flows by modulation of rotation velocity, and the second pump worked at constant rotation velocity, ensuring the counter pressure levels and backflows. The flow rate, the velocity profile, the arterial pressure, and the resistance of the flow were adjustable. The bioreactor was placed in an incubator to reproduce a biological environment. A first feasibility experience was performed over a 24-day period. Three rat aortic thoracic arteries were placed into the bioreactor, immersed in cell culture medium changed every 3 days, and with a circulating systolic and diastolic flux during the entire experimentation. There was no infection and no leak. At the end of the experimentation, a morphometric analysis was performed confirming the viability of the arteries. We designed and patented an original hemodynamic ex vivo model to further study new DES, as well as a wide range of vascular diseases and medical devices. This bioreactor will allow characterization of the velocity field and drug transfers within a stented artery with new functionalized DES, with experimental means not available in vivo. Another major benefit will be the reduction of animal experimentation and the opportunity to test new DES or other vascular therapeutics in human tissues (human infrapopliteal or coronary arteries collected during human donation). Copyright © 2015 Elsevier Inc. All rights reserved.
Temporary diabetes insipidus in 2 men after on-pump coronary artery bypass grafting.
Uyar, Ihsan Sami; Sahin, Veysel; Akpinar, Besir; Yurtman, Volkan; Abacilar, Feyzi; Okur, Faik Fevzi; Ates, Mehmet
2013-01-01
Many complications have been reported after cardiopulmonary bypass. A common physiologic change during the early postoperative period after cardiopulmonary bypass is increased diuresis. In patients whose urine output is increased, postoperative diabetes insipidus can develop, although reports of this are rare. We present the cases of 2 patients who underwent on-pump coronary artery bypass grafting (with cardiopulmonary bypass). Each was diagnosed with diabetes insipidus postoperatively: a 54-year-old man on the 3rd day, and a 66-year-old man on the 4th day. Each patient recovered from the condition after 6 hours of intranasal therapy with synthetic vasopressin (antidiuretic hormone). The diagnosis of diabetes insipidus should be considered in patients who produce excessive urine early after cardiac surgery in which cardiopulmonary bypass has been used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Afeyan, Bedros; Charbonneau-Lefort, Mathieu; Fejer, Martin
With a finite lateral width pump, non-collinear interactions result in metastable or stable laterally localized bound states. The physical processes involved are group velocity walk-off, diffraction, chirped QPM gratings and different pump shapes.
Self-regenerating Nanotips: Indestructable Field-emission Cathodes for Low-power Electric Propulsion
2010-09-27
Field Emission Scanning Electron Microscope. The chamber was evacuated using a series of three ion pumps and vacuum pressure of 10-7 Torr was...backed by a 110-L/min dry scroll pump . The chamber is also equipped with a 300-L/s combination ion/sublimation pump that can maintain pressure of...Torr for 2 to 24 hours and then the ion pump was turned off to let the vacuum pressure slowly increase while observing the electron emission
Remotely Adjustable Hydraulic Pump
NASA Technical Reports Server (NTRS)
Kouns, H. H.; Gardner, L. D.
1987-01-01
Outlet pressure adjusted to match varying loads. Electrohydraulic servo has positioned sleeve in leftmost position, adjusting outlet pressure to maximum value. Sleeve in equilibrium position, with control land covering control port. For lowest pressure setting, sleeve shifted toward right by increased pressure on sleeve shoulder from servovalve. Pump used in aircraft and robots, where hydraulic actuators repeatedly turned on and off, changing pump load frequently and over wide range.
Aref, S
1982-01-01
A study of the migration of fourth stage larvae of the parasite Strongylus vulgaris in the intestinal arteries of the horse is presented. It is established, that the larvae migrate along the arteries in almost straight lines. It is suggested that this is primarily due to their ability to sense the curvature of the vessel wall, and not, as might have been expected, because of an ability to sense the direction of blood flow. A larva will sometimes alter its direction of motion when encountering a small off-branching artery. This behaviour suggests, that the migration of S. vulgaris larvae can be modeled as a one-dimensional discrete random walk on a long time scale. This model is simpler than any deterministic model and, in particular, does not require the existence of a predilection site. The available data is not, however, sufficient for a convincing, quantitative test of the model. The proposed reluctance of the larvae to bend into off-branching arteries is used to explain the crowding of larvae in the cranial mesenteric artery.
Development of the NEDO implantable ventricular assist device with Gyro centrifugal pump.
Yoshikawa, M; Nonaka, K; Linneweber, J; Kawahito, S; Ohtsuka, G; Nakata, K; Takano, T; Schulte-Eistrup, S; Glueck, J; Schima, H; Wolner, E; Nosé, Y
2000-06-01
The Gyro centrifugal pump, PI (permanently implantable) series, is being developed as a totally implantable artificial heart. Our final goal is to establish a "functional TAH," a totally implantable biventricular assist system (BiVAS) with centrifugal pumps. A plastic prototype pump, Gyro PI 601, was evaluated through in vitro and in vivo studies as a single ventricular assist device (VAD). Based upon these results, the pump head material was converted to a titanium alloy, and the actuator was modified. These titanium Gyro pumps, PI 700 series, also were subjected to in vitro and in vivo studies. The Gyro PI 601 and PI 700 series have the same inner dimensions and characteristics, such as the eccentric inlet port, double pivot bearing system, secondary vane, and magnet coupling system; however, the material of the PI 700 is different from the PI 601. The Gyro PI series is driven by the Vienna DC brushless motor actuator. The inlet cannula of the right ventricular assist system (RVAS) specially made for this system consists of 2 parts: a hat-shaped silicone tip biolized with gelatin and an angled wire reinforced tube made of polyvinylchloride. The pump-actuator package was implanted into 8 calves in the preperitoneal space, bypassing from the left ventricle apex to the descending aorta for the left ventricular assist system (LVAS) and bypassing the right ventricle to the main pulmonary artery for the RVAS. According to the PI 601 feasibility protocol, 2 LVAS cases were terminated after 2 weeks, and 1 LVAS case and 1 RVAS were terminated after 1 month. The PI 700 series was implanted into 4 cases: 3 LVAS cases survived for a long term, 2 of them over 200 days (72-283 days), and 1 RVAS case survived for 1 month and was terminated according to the protocol for a short-term antithrombogenic screening and system feasibility study. Regarding power consumption, the plastic pump cases demonstrated from 6.2 to 12.1 W as LVAS and 7.3 W as RVAS, the titanium pump cases showed from 10.4 to 14.2 W as LVAS and 15.8 W as RVAS. All cases exhibited low hemolysis. The renal function and the liver function were maintained normally in all cases throughout these experimental periods. In the 2 RVAS cases, pulmonary function was normally maintained. No calves demonstrated thromboembolic signs or symptoms throughout the experiments except Case 1 with the plastic pump. However, in the plastic pump cases, bilateral renal infarction was suspected in 2 cases during necropsy whereas no abnormal findings were revealed in the titanium pump cases. There were also no blood clots inside the PI 700 series. As for the 601, the explanted pumps demonstrated slight thrombus formations at the top and bottom pivots except in 1 case. The Gyro PI series, especially the PI 700 series, demonstrated superior performance, biocompatibility, antithrombogenicity and low hemolysis. Also, the durability of the actuator was demonstrated. Based on these results, this titanium centrifugal pump is suitable as an implantable LVAS and RVAS. It is likely that the Gyro PI series is a feasible component of the BiVAS functional TAH.
Uncu, Hasan; Acipayam, Mehmet; Altinay, Levent; Doğan, Pinar; Davarcı, Isil; Özsöyler, İbrahim
2014-01-01
Introduction In this retrospective study, we aimed to determine the risk factors for coronary artery bypass surgery in patients under 45 years of age, and evaluate the early postoperative results and the effect of gender. Methods A total of 324 patients under 45 years of age who undergone on-pump coronary artery bypass surgery between April 12, 2004 and January 10, 2012 were included to the study. Patients divided into groups as follows: Group 1 consisted of 269 males (mean age 41.3), Group 2 consisted of 55 females (mean age 41.6). Preoperative risk factors, intraoperative and postoperative data and early mortality rates of the groups were compared. Results Smoking rate was significantly higher in Group 1. Diabetes mellitus incidence and body mass index were significantly higher in Group 2 (P values P=0.01; P=0.0001; P=0.04 respectively). The aortic cross-clamping and cardiopulmonary bypass time and number of grafts per patient were significantly higher in Group 1 (P values P=0.04; P=0.04; P=0.002 respectively). There were no deaths in either group. Conclusion We found that gender has no effect on early mortality rates of the coronary bypass surgery patients under 45 years. PMID:25714211
Quantum theory of the far-off-resonance continuous-wave Raman laser: Heisenberg-Langevin approach
NASA Astrophysics Data System (ADS)
Roos, P. A.; Murphy, S. K.; Meng, L. S.; Carlsten, J. L.; Ralph, T. C.; White, A. G.; Brasseur, J. K.
2003-07-01
We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump ↔ pump, Stokes ↔ signal, and Raman coherence ↔ idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions.
Bordalo, Alvaro D B; Nobre, Angelo L; Silva, Fernanda; Serpa, Carlos; Cravino, João
2011-01-01
In spite of the strong criticism elicited thereafter, the results of a multicentric study on the consequences of several perioperative anti-hemorrhagic strategies in cardiac surgery, published five years ago, led to the aprotinin (Aprot) withdrawal from the market and its progressive replacement by tranexamic acid (TrAc) in many surgical departments. To evaluate the hemostatic effects and clinical consequences of TrAc use or non-use in off-pump coronary bypass surgery (CABG) and compare them with those of Aprot use or non-use in conventional (conv) CABG. Retrospective analysis of 2 groups (Gr) of patients (pts): GrA - 252 pts undergoing isolated conv CABG (GrA1 - 185 pts submitted to an intra-operative full-dose Aprot protocol; GrA2 - 67 pts operated without Aprot); GrB - 383 pts undergoing isolated off-pump CABG (GrB1 - 136 pts submitted to an intra-operative low-dose TrAc protocol; GrB2 - 247 pts operated in absence of TrAc). Pre-operative clinical characteristics (GrA1 vs GrA2, GrB1 vs GrB2): mean age (years) - 65 vs 64 (NS), 64 vs 64; female gender - 20% vs 21% (NS), 23% vs 20% (NS); logistic Euroscore - 5.1% vs 6.2% (NS), 6.3% vs 5.5% (NS); chronic renal failure - 21% vs 27% (NS), 27% vs 25% (NS); diffuse coronary artery disease - 34% vs 42% (NS), 36% vs 30% (NS); pre-operative betablocker treatment - 64% vs 55% (NS), 74% vs 71% (NS); statin therapy for > 3 months - 78% vs 82% (NS), 81% vs 85% (NS). Pts have been operated by 4 surgeons largely experienced in both CABG modalities. Antiplatelet therapy was stopped => 4 days prior to surgery (but aspirin was maintained in high-risk pts). Results (GrA1 vs GrA2, GrB1 vs GrB2): 1) Bleeding (mL/pt - mean): 783 vs 1375 (p < 0.001), 1061 vs 1368 (p < 0.001); blood loss > 1500 mL (%pts) - 5.4% vs 34% (p < 0.0001), 12% vs 28% (p < 0.001); surgical re-exploration for bleeding - 1.1% vs 3.0% (NS), 2.2% vs 2.0% (NS). 2) Transfusion of blood products (U/pt - mean): plasma - 0.56 vs 2.19 (p < 0.001), 1.45 vs 1.03 (p < 0.05); platelets - 0.09 vs 0.22 (p < 0.02), 0.24 vs 0.15 (NS). 3) Renal function (%pts): increased serum cre- atinine - 56% vs 56%, 55% vs 38% (p < 0.001); hemofiltration use - 1.1% vs 1.5% (NS), 1.5% vs 0.4% (NS). 4) Perioperative myocardial infarction - 21.6% vs 17.9% (NS), 17.6% vs 14.6% (NS); other ischemic events - 3.2% vs 3.0% (NS), 1.5% vs 1.2% (NS). 5) Hospital mortality: 4.8% vs 4.5% (NS), 4.4% vs 1.6% (NS). 1) TrAc does not reduce the risk of surgical re-exploration for bleeding. 2) Taking into account the differences between conv CABG and off-pump CABG, TrAc hemostatic effect seems to be inferior to that of Aprot, without offering a better safety profile in terms of lesser renal or ischemic risk as a counterpart.
Lee, Pil Hyung; Kang, Se Hun; Han, Seungbong; Ahn, Jung-Min; Bae, Jae Seok; Lee, Cheol Hyun; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Park, Duk-Woo; Park, Seung-Jung
2017-12-01
The aim of this study was to determine how trial-based findings of EXCEL and NOBLE might be interpreted and generalizable in 'real-world' settings with comparison of data from the large-scaled, all-comer Interventional Research Incorporation Society-Left MAIN Revascularization (IRIS-MAIN) registry. We compared baseline clinical and procedural characteristics and also determined how the relative treatment effect of percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) was different in EXCEL and NOBLE, compared with those of the multicenter, IRIS-MAIN registry (n=2481). The primary outcome for between-study comparison was a composite of death, myocardial infarction (MI), or stroke. There were between-study differences in patient risk profiles (age, BMI, diabetes, and clinical presentation), lesion complexities, and procedural characteristics (stent type, the use of off-pump surgery, and radial artery); the proportion of diabetes and acute coronary syndrome was particularly lower in NOBLE than in other studies. Although there was interstudy heterogeneity for the protocol definition of MI, the risks for serious composite outcome of death, MI, or stroke were similar between PCI and CABG in EXCEL [hazard ratio (HR): 1.00; 95% confidence interval (CI): 0.79-1.26; P=0.98] and in the matched cohort of IRIS-MAIN (HR: 1.08; 95%CI: 0.85-1.38; P=0.53), whereas it was significantly higher after PCI than after CABG in NOBLE (HR: 1.47; 95%CI: 1.06-2.05; P=0.02), which was driven by more common MI and stroke after PCI. In the comparison of a large-sized, all-comer registry, the EXCEL trial might represent better generalizability with respect to baseline characteristics and observed clinical outcomes compared with the NOBLE trial.
Wang, Shigang; Spencer, Shannon B; Woitas, Karl; Glass, Kristen; Kunselman, Allen R; Ündar, Akif
2017-01-01
The objective of this study is to evaluate the impact of an open or closed recirculation line on flow rate, circuit pressure, and hemodynamic energy transmission in simulated neonatal extracorporeal life support (ECLS) systems. The two neonatal ECLS circuits consisted of a Maquet HL20 roller pump (RP group) or a RotaFlow centrifugal pump (CP group), Quadrox-iD Pediatric oxygenator, and Biomedicus arterial and venous cannulae (8 Fr and 10 Fr) primed with lactated Ringer's solution and packed red blood cells (hematocrit 35%). Trials were conducted at flow rates ranging from 200 to 600 mL/min (200 mL/min increments) with a closed or open recirculation line at 36°C. Real-time pressure and flow data were recorded using a custom-based data acquisition system. In the RP group, the preoxygenator flow did not change when the recirculation line was open while the prearterial cannula flow decreased by 15.7-20.0% (P < 0.01). Circuit pressure, total circuit pressure drop, and hemodynamic energy delivered to patients also decreased (P < 0.01). In the CP group, the prearterial cannula flow did not change while preoxygenator flow increased by 13.6-18.8% (P < 0.01). Circuit pressure drop and hemodynamic energy transmission remained the same. The results showed that the shunt of an open recirculation line could decrease perfusion flow in patients in the ECLS circuit using a roller pump, but did not change perfusion flow in the circuit using a centrifugal pump. An additional flow sensor is needed to monitor perfusion flow in patients if any shunts exist in the ECLS circuit. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Method to improve optical parametric oscillator beam quality
Smith, Arlee V.; Alford, William J.; Bowers, Mark S.
2003-11-11
A method to improving optical parametric oscillator (OPO) beam quality having an optical pump, which generates a pump beam at a pump frequency greater than a desired signal frequency, a nonlinear optical medium oriented so that a signal wave at the desired signal frequency and a corresponding idler wave are produced when the pump beam (wave) propagates through the nonlinear optical medium, resulting in beam walk off of the signal and idler waves, and an optical cavity which directs the signal wave to repeatedly pass through the nonlinear optical medium, said optical cavity comprising an equivalently even number of non-planar mirrors that produce image rotation on each pass through the nonlinear optical medium. Utilizing beam walk off where the signal wave and said idler wave have nonparallel Poynting vectors in the nonlinear medium and image rotation, a correlation zone of distance equal to approximately .rho.L.sub.crystal is created which, through multiple passes through the nonlinear medium, improves the beam quality of the OPO output.
Optical parametric osicllators with improved beam quality
Smith, Arlee V.; Alford, William J.
2003-11-11
An optical parametric oscillator (OPO) having an optical pump, which generates a pump beam at a pump frequency greater than a desired signal frequency, a nonlinear optical medium oriented so that a signal wave at the desired signal frequency and a corresponding idler wave are produced when the pump beam (wave) propagates through the nonlinear optical medium, resulting in beam walk off of the signal and idler waves, and an optical cavity which directs the signal wave to repeatedly pass through the nonlinear optical medium, said optical cavity comprising an equivalently even number of non-planar mirrors that produce image rotation on each pass through the nonlinear optical medium. Utilizing beam walk off where the signal wave and said idler wave have nonparallel Poynting vectors in the nonlinear medium and image rotation, a correlation zone of distance equal to approximately .rho.L.sub.crystal is created which, through multiple passes through the nonlinear medium, improves the beam quality of the OPO output.
Advanced heat pump for the recovery of volatile organic compounds
NASA Astrophysics Data System (ADS)
1992-03-01
Emissions of Volatile Organic Compounds (VOC) from stationary industrial and commercial sources represent a substantial portion of the total U.S. VOC emissions. The 'Toxic-Release Inventory' of the U.S. Environmental Protection Agency estimates this to be at about 3 billion pounds per year (1987 estimates). The majority of these VOC emissions are from coating processes, cleaning processes, polymer production, fuel production and distribution, foam blowing, refrigerant production, and wood products production. The U.S. Department of Energy's (DOE) interest in the recovery of VOC stems from the energy embodied in the recovered solvents and the energy required to dispose of them in an environmentally acceptable manner. This Phase 1 report documents 3M's work in close working relationship with its subcontractor Nuclear Consulting Services (Nucon) for the preliminary conceptual design of an advanced Brayton cycle heat pump for the recovery of VOC. The Nucon designed Brayton cycle heat pump for the recovery of methyl ethyl ketone and toluene from coating operations at 3M Weatherford, OK, was used as a base line for the work under cooperative agreement between 3M and ODE. See appendix A and reference (4) by Kovach of Nucon. This cooperative agreement report evaluates and compares an advanced Brayton cycle heat pump for solvent recovery with other competing technologies for solvent recovery and reuse. This advanced Brayton cycle heat pump is simple (very few components), highly reliable (off the shelf components), energy efficient, and economically priced.
Smith, Elliot J; Reitan, Oyvind; Keeble, Thomas; Dixon, Kerry; Rothman, Martin T
2009-06-01
To investigate the safety of a novel percutaneous circulatory support device during high-risk percutaneous coronary intervention (PCI). The Reitan catheter pump (RCP) consists of a catheter-mounted pump-head with a foldable propeller and surrounding cage. Positioned in the descending aorta the pump creates a pressure gradient, reducing afterload and enhancing organ perfusion. Ten consecutive patients requiring circulatory support underwent PCI; mean age 71 +/- 9; LVEF 34% +/- 11%; jeopardy score 8 +/- 2.3. The RCP was inserted via the femoral artery. Hemostasis was achieved using Perclose sutures. PCI was performed via the radial artery. Outcomes included in-hospital death, MI, stroke, and vascular injury. Hemoglobin (Hb), free plasma Hb (fHb), platelets, and creatinine (cre) were measured pre PCI and post RCP removal. The pump was inserted and operated successfully in 9/10 cases (median 79 min). Propeller rotation at 10,444 +/- 1,424 rpm maintained an aortic gradient of 9.8 +/- 2 mm Hg. Although fHb increased, there was no significant hemolysis (4.7 +/- 2.4 mg/dl pre vs. 11.9 +/- 10.5 post, P = 0.04, reference 20 mg/dl). Platelets were unchanged (pre 257 +/- 74 x 10(9) vs. 245 +/- 63, P = NS). Renal function improved (cre pre 110 +/- 27 micromol/l vs. 99 +/- 28, P = 0.004). The RCP was not used in one patient following femoral introducer sheath related aortic dissection. All PCI procedures were successful with no deaths or strokes, one MI, and no vascular complications following pump removal. The RCP can be used safely in high-risk PCI patients. This device may be an alternative to other percutaneous systems when substantial cardiac support is needed. (c) 2009 Wiley-Liss, Inc.
Litmathe, J; Hansen, E; Feindt, P; Kurt, M; Boeken, U; Gams, E
2009-01-01
Myocardial revascularization using a complete heart-lung machine may involve many problems, as do complete off-pump attempts. Thus, it was the aim of this study to evaluate the effects of intermediate on-pump/off-pump myocardial revascularization using the miniaturized Deltastream blood pump, on ischemia and hemolysis, in comparison with standard myocardial revascularization. In a group of 8 mini-pigs, combined on-pump/off-pump myocardial revascularization was performed using the Deltastream blood pump as beating-heart support for the on-pump part of the operation (group A). Seven other animals served as controls and underwent standard myocardial revascularization with the same device as integrated pump of a complete heart-lung machine (group B). Blood samples for blood gas metabolism, creatine kinase (CK), troponin I, lactate dehydrogenase (LDH), and hydroxybutyrate dehydrogenase (HBDH) were taken before and after the entire operation. Comparing the baseline values, the increase of CK was more pronounced in group B than in group A (176.4-/+41.2 to 279.7-/+29 U/L vs. 274-/+142.7 to 288.1-/+118.6 U/L, respectively; p=0.0006). Increase of troponin I was significantly higher in group B than in group A (1-/+0.3 to 2.9-/+1 ng/mL vs. 1.1-/+0.9 to 3-/+3.8 ng/mL, respectively; p=0.002). LDH increase was also more pronounced in group B (231.7-/+54.3 to 299.9-/+39.8 U/L vs. 274.9-/+59.7 to 263.8-/+57.9 U/L, respectively; p=0.01). HBDH values increased significantly in group B after the operation (group A: 215.9-/+34.7 to 200-/+39.2 U/L vs. group B: 195.4-/+41.7 to 274.9-/+51.6 U/L; p=0.02). Hemodynamic measures and LDH values under luxation (group A: 1.9-/+0.6 U/L; B: 3.5-/+1 U/L,p=0.001) were also superior in the study group. The current set-up might be superior to conventional extracorporeal circulation and thus be an alternative for high-risk candidates to avoid the adverse events of a complete heart-lung machine, when they are scheduled for complete myocardial revascularization.
Angioplasty of below-the-elbow arteries in critical hand ischaemia.
Ferraresi, R; Palloshi, A; Aprigliano, G; Caravaggi, C; Centola, M; Sozzi, F; Danzi, G B; Manzi, M
2012-01-01
Critical hand ischaemia (CHI) due to pure below-the-elbow (BTE) artery obstruction is a disabling disease and there is still no consensus concerning the most appropriate revascularisation strategy. The aim of this study was to assess the feasibility, safety and outcomes of percutaneous transluminal angioplasty (PTA) in the treatment of CHI due to pure BTE artery disease. Twenty-eight patients (age 62 ± 11 years; three females) with a total of 34 hands affected by CHI (one pain at rest; 18 non-healing ulcer; 15 gangrene) due to pure BTE artery disease underwent PTA. Most of the patients were males with a long history of diabetes mellitus, end-stage renal disease (ESRD) on haemodialysis and systemic atherosclerosis. The interosseous artery was free of disease in all cases, whereas the radial and ulnar arteries were simultaneously involved in 31/34 hands with long stenosis/occlusions (91%; mean length 155 ± 64 mm). The technical success rate was 82% (28/34), with only three minor complications. In the three cases with a functioning radial arteriovenous fistula, we successfully treated the ulnar artery. PTA was unsuccessful in 18% (6/34) hands due to inability to cross severely calcified lesions. The hand-healing rate was 65% (22/34). The predictors of hand healing were PTA technical success (odds ratio (OR) 0.5, confidence interval (CI) 0.28-0.88; p ≤ 0.0001) and digital run-off (OR 0.37, CI 0.19-0.71; p ≤ 0.003). The mean follow-up period was 13 ± 9 months. Six patients (18%) underwent secondary procedures due to symptomatic restenosis. In all these cases, a successful re-PTA was performed at a mean 6 months after the index procedure, and there were no major procedure-related events. Ten patients (36%) died during follow-up. Angioplasty of BTE vessels for CHI is a feasible and safe procedure with acceptable rates of technical success and hand healing. Poor digital run-off due to obstructive disease of the digital vessels can reduce the hand-healing rate after a successful PTA. Pure isolated BTE vessel disease seems to characterise patients with ESRD and diabetes mellitus. Copyright © 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Joshi, Hasit; Sahoo, Sibasis; Virpariya, Kapil; Parmar, Meena; Shah, Komal
2015-01-01
Context Although numerous risk factors have been established to predict the development of acute coronary syndrome (ACS), the risk factor profile may be different between the younger and older individuals. Aim To analyse the frequency and pattern of atherogenic risk factors and angiographic profiles in age-stratified Gujarati patients with ACS. Materials and Methods ACS patients undergoing coronary angiography at U.N. Mehta Institute of Cardiology and Research, Gujarat, India between January 2008 and December 2012 were classified in to two age groups with 40y as cut-off. Patients were assessed for conventional risk factors (diabetes mellitus, dyslipidaemia, hypertension, smoking, obesity), novel risk factors (high sensitivity C-reactive protein, lipoprotein (a), homocysteine), and angiographic profiles.The statistical difference between two age groups was determined by Student’s t-test for continuous variables and Chi-square or Fisher’s exact test for categorical variables. Results A total of 200 patients, 100 patients ≤40 y of age and 100 patients >40 y of age, were evaluated. Older patients had higher frequency of hypertension (32 vs. 16%, p=0.008), while family history of coronary artery disease was more common among younger patients (19 vs. 9%, p=0.041). The incidence of diabetes, dyslipidaemia, smoking and tobacco chewing did not vary significantly between the two groups. Total cholesterol and low-density lipoprotein cholesterol levels were significantly higher in the younger group (p<0.05). Lipoprotein (a), homocysteine and high-sensitivity C reactive protein levels were comparable between two age groups. Multi-vessel coronary artery disease was more common among older group. The most commonly affected coronary artery was the left anterior descending artery among younger patients (44%) and the left circumflex artery among older patients (38.1%). Conclusion Young patients with ACS had different atherosclerotic risk profile and less extensive coronary artery disease as compared to older counterparts. Emphasis should be given on diagnosis and management of major modifiable risk factors. PMID:26266146
Speed, speed variation and crash relationships for urban arterials.
Wang, Xuesong; Zhou, Qingya; Quddus, Mohammed; Fan, Tianxiang; Fang, Shou'en
2018-04-01
Speed and speed variation are closely associated with traffic safety. There is, however, a dearth of research on this subject for the case of urban arterials in general, and in the context of developing nations. In downtown Shanghai, the traffic conditions in each direction are very different by time of day, and speed characteristics during peak hours are also greatly different from those during off-peak hours. Considering that traffic demand changes with time and in different directions, arterials in this study were divided into one-way segments by the direction of flow, and time of day was differentiated and controlled for. In terms of data collection, traditional fixed-based methods have been widely used in previous studies, but they fail to capture the spatio-temporal distributions of speed along a road. A new approach is introduced to estimate speed variation by integrating spatio-temporal speed fluctuation of a single vehicle with speed differences between vehicles using taxi-based high frequency GPS data. With this approach, this paper aims to comprehensively establish a relationship between mean speed, speed variation and traffic crashes for the purpose of formulating effective speed management measures, specifically using an urban dataset. From a total of 234 one-way road segments from eight arterials in Shanghai, mean speed, speed variation, geometric design features, traffic volume, and crash data were collected. Because the safety effects of mean speed and speed variation may vary at different segment lengths, arterials with similar signal spacing density were grouped together. To account for potential correlations among these segments, a hierarchical Poisson log-normal model with random effects was developed. Results show that a 1% increase in mean speed on urban arterials was associated with a 0.7% increase in total crashes, and larger speed variation was also associated with increased crash frequency. Copyright © 2018 Elsevier Ltd. All rights reserved.
In vivo experimental testing of a microaxial blood pump for right ventricular support.
Christiansen, Stefan; Perez-Bouza, Alberto; Reul, Helmut; Autschbach, Rüdiger
2006-02-01
The incidence of isolated right ventricular (RV) failure is rare in postcardiotomy patients, but high in patients undergoing implantation of a left ventricular assist device or cardiac transplantation. Therefore, we have developed a new microaxial flow device and report on our first in vivo animal trials. Six healthy adult female sheep weighing 80-90 kg underwent implantation of the microaxial blood pump for partial unloading of the right ventricle. This pump is a miniaturized rotary blood pump with a diameter of only 6.4 mm and a weight of 11 g. The inner volume of the pump is limited to 12 mL, and the inner artificial blood contacting surface is 65 cm(2). The pump consists of a rotor driven by an incorporated brushless direct current motor, the housing of the rotor, the inflow cage, the outflow cannula, and the driveline. At the maximum speed of 32,500 rotations/min, a flow of 6 L/min can be delivered. The inflow and outflow conduit were anastomosed to the right atrium and the main pulmonary artery, respectively. Hemodynamic and echocardiographic data as well as blood samples were measured over the whole test period of 7 days. The hearts and lungs as well as the pump were explanted for a thorough examination at the end of the trial. Systemic arterial blood pressures remained unchanged during the entire test period. RV cardiac output was diminished significantly as demonstrated by the echocardiographic studies. The number of platelets decreased perioperatively, but recovered within the test period. The free hemoglobin was not enhanced postoperatively indicating no significant hemolysis. Liver function was only slightly impaired due to operative reasons (increase in bilirubin on the first postoperative day but normalization within the test period). The pathologic examination revealed some clots at the inflow cage and fibrin depositions on the impeller as well as on the inner surface of the outflow graft without an impairment of pump function. Our results demonstrate that this newly developed microaxial blood pump is a promising device for RV support, but it cannot be driven without any anticoagulation.
NASA Technical Reports Server (NTRS)
Lubenetsky, W S
1936-01-01
This report presents investigations into the design and construction of fuel pumps for diesel engines. The results of the pump tests on the engines showed that, with a good cut-off, accurate injection, assured by the proper adjustment of the pump elements, there is a decrease in the consumption of fuel and hence an increase in the rated power of the engine. Some of the aspects investigated include: cam profile, coefficient of discharge, and characteristics of the injection system.
Anomalous vertebral artery origins: the first and second reports of two variants.
Hsu, Daniel P; Alexander, Ashley D; Gilkeson, Robert C
2010-06-01
We present two cases of aberrant origins of vertebral arteries. Case 1 is of a patient undergoing evaluation of an infrarenal aortic aneurysm stent graft. Computed tomography (CT) angiogram revealed an aberrant right vertebral artery that subsequently joined a second right vertebral artery that had the typical origin off the right subclavian artery. This represents an unusual anatomic variation not previously reported in the literature. Case 2 is of a patient being evaluated for thoracic aorta injury. CT angiogram of the chest revealed a five-vessel aortic arch with aberrant origin of the bilateral vertebral arteries distal to the left subclavian artery.
A new static sampler for airborne total dust in workplaces.
Mark, D; Vincent, J H; Gibson, H; Lynch, G
1985-03-01
This paper describes the development and laboratory testing of a new static dust sampler for airborne total dust in workplaces. Particular attention is paid to designing the sampling head and entry consistent with the concept of inspirability which in turn defines a biologically-relevant aspiration efficiency. The sampling head has a small cylindrical body and a transverse entry slot with thin protruding lips forming an integral part of a weighable capsule containing a 37 mm filter which collects all of the sampled dust (without introducing errors due to external particle blow-off or internal wall losses). A battery-powered sampling pump provides both air suction at 3 L/min and rigid mounting for the sampling head. The sampling head is rotated continuously through 360 degrees at approximately 1.5 rpm by a simple electric drive, connected to the stationary pump through a rotating seal. Wind tunnel testing of the instrument showed it to display an entry efficiency very close to the inspirability curve of Vincent and Armbruster (now recommended by the ACGIH Technical Committee on Air Sampling Procedures for defining inspirable particulate matter (IPM] for particles of aerodynamic diameter up to 90 micron and for windspeeds in the range of one to three m/sec.
Novel anatomic variation: heptafurcation of the celiac trunk.
Rusu, M C; Manta, B A
2018-04-01
We report here anatomic variants which were found during a retrospective study of a male patient, 54 years old, evaluated in computed tomography: heptafurcation of the celiac trunk (CT) and bilateral double renal arteries. The seven branches of the heptafurcated CT were the (1) left and (2) right inferior phrenic arteries, the (3) splenic and (4) left gastric artery, the (5) common hepatic artery, further sending off the (a) proper, continued as left, hepatic artery and (b) the gastroduodenal artery, (6) a replaced right hepatic artery and (7) the dorsal pancreatic artery. To our knowledge, heptafurcation of the CT was not reported previously. The arterial variants have great importance during various surgical and interventional procedures and should be documented prior to respective procedures.
NASA Astrophysics Data System (ADS)
Edemskii, M. L.; Kogan, V. A.
1981-07-01
Relative to its major function, pumping, the heart should be considered as an integral musculovascular organ. It is precisely this integration in the structural and functional sense which permits the heart not only to perform its pump function as a converter of chemical energy supplied by the blood into mechanical flow energy but also to combine the supply and conversion of energy into a single cycle, produce the hydrodynamics of cardiac output in definite fashion, and introduce a correction into the filling phase according to current arterial pressure as the most dynamic index of systemic hemodynamics. The breakdown of the structure of the cardiac pump into elements differing in their functional significance permits us to delineate at least three channels for the utilization of energy supplied to the heart and consumed in the major pumping function: the mechanical work performed by the lower part of the cardiac muscle that is displaced into the ventricular space, the energy consumed on maintaining the systolic pressure of the myocardial fibers which form the relatively immobile upper and side walls of the heart, and the energy consumed on maintaining the high tone of the muscular walls of the coronary arteries and arterioles which form the hydraulic frame of the heart. A representation of the heart which includes muscular and vascular components, in our view, is the basic prerequisite for the development of mathematical models for the cardiac pump based on energy balance equations and suitable for solving the problems posed by clinical medicine in regard to auxiliary blood circulation.
Series-parallel solar-augmented rock-bed heat pump. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sowell, E.F.; Othmer, P.W.
1979-12-31
This report deals with a system representing an alternate arrangement of the components in an air-type, heat pump augmented solar heating system. In this system, referred to as Series-Parallel, the heat pump coils are at opposite ends of the rock bed, allowing heating and cooling of the air entering and leaving the bed. This allows a number of unique modes of operation, some of which allow off-peak use of the necessary utility power. Cooling modes are also available, including off-peak cooling-effect storage, night cooling, and free cooling (economizing). The system finds applications principally in single-family residences. The study examined themore » performance of this system at three locations (Sacramento, Albuquerque, and New York) by means of a simulation model. Seasonal heating and cooling performance factors of about 3 were obtained for Albuquerque for the system integrated into a 200 m/sup 2/ residence. Design integration studies suggest an installed cost of approximately $28,000 above a conventional heat pump system using commercially available components. This high cost is largely due to solar hardware, although system complexity also adds. Availability of low-cost air type collectors may make the system attractive. The study also addresses the general problem of predictive control necessary whenever off-peak storage is employed. An algorithm is presented, along with results.« less
López-Ibáñez, Manuel; Prasad, T Devi; Paechter, Ben
2011-01-01
Reducing the energy consumption of water distribution networks has never had more significance. The greatest energy savings can be obtained by carefully scheduling the operations of pumps. Schedules can be defined either implicitly, in terms of other elements of the network such as tank levels; or explicitly, by specifying the time during which each pump is on/off. The traditional representation of explicit schedules is a string of binary values with each bit representing pump on/off status during a particular time interval. In this paper, we formally define and analyze two new explicit representations based on time-controlled triggers, where the maximum number of pump switches is established beforehand and the schedule may contain fewer than the maximum number of switches. In these representations, a pump schedule is divided into a series of integers with each integer representing the number of hours for which a pump is active/inactive. This reduces the number of potential schedules compared to the binary representation, and allows the algorithm to operate on the feasible region of the search space. We propose evolutionary operators for these two new representations. The new representations and their corresponding operations are compared with the two most-used representations in pump scheduling, namely, binary representation and level-controlled triggers. A detailed statistical analysis of the results indicates which parameters have the greatest effect on the performance of evolutionary algorithms. The empirical results show that an evolutionary algorithm using the proposed representations is an improvement over the results obtained by a recent state of the art hybrid genetic algorithm for pump scheduling using level-controlled triggers.
Prediction of early and late preeclampsia by flow-mediated dilation of the brachial artery*
Brandão, Augusto Henriques Fulgêncio; Evangelista, Aline Aarão; Martins, Raphaela Menin Franco; Leite, Henrique Vítor; Cabral, Antônio Carlos Vieira
2014-01-01
Objective To assess the accuracy in the prediction of both early and late preeclampsia by flow-mediated dilation of the brachial artery (FMD), a biophysical marker for endothelial dysfunction. Materials and Methods A total of 91 patients, considered at high risk for development of preeclampsia were submitted to brachial artery FMD between 24 and 28 weeks of gestation. Results Nineteen out of the selected patients developed preeclampsia, 8 in its early form and 11 in the late form. With a cut-off value of 6.5%, the FMD sensitivity for early preeclampsia prediction was 75.0%, with specificity of 73.3%, positive predictive value (PPV) of 32.4% and negative predictive value (NPV) of 91.9%. For the prediction of late preeclampsia, sensitivity = 83.3%, specificity = 73.2%, PPV = 34.4% and NPV = 96.2% were observed. And for the prediction of all associated forms of preeclampsia, sensitivity = 84.2%, specificity = 73.6%, PPV = 45.7% and NPV = 94.6% were observed. Conclusion FMD of the brachial artery is a test with good accuracy in the prediction of both early and late preeclampsia, which may represent a positive impact on the follow-up of pregnant women at high risk for developing this syndrome. PMID:25741086
Coronary bypass flow during use of intraaortic balloon pumping and left ventricular assist device.
Tedoriya, T; Kawasuji, M; Sakakibara, N; Takemura, H; Watanabe, Y; Hetzer, R
1998-08-01
Intraaortic balloon pumping (IABP) and left ventricular assist device (LVAD) are used for left ventricular support when low cardiac output occurs after a coronary bypass operation for serious coronary artery disease. There are hemodynamic differences in blood flow in various kinds of coronary artery bypass grafts, caused by their inherent physiologic characteristics. The hemodynamic effects of left ventricular assistance with IABP and LVAD on blood flow through various coronary artery bypass grafts were investigated. An ascending aorta-coronary bypass graft (ACB), an internal thoracic artery, and a descending aorta-coronary bypass graft were anastomosed to the left anterior descending coronary artery in a canine model. In this experimental model, the blood flow to the same coronary bed in the three types of grafts could be evaluated. Blood flow in the left anterior descending coronary artery through the three types of coronary bypass grafts was studied in this model during or in the absence of ventricular assistance. In the control study, the systolic blood flow did not differ among the three types of grafts, but the diastolic flow decreased in the following order: with the ACB, the internal thoracic artery, and the descending aorta-coronary bypass graft. The systolic flow during IABP and LVAD was similar to the control flows. Use of IABP increased the diastolic flow by 75.3%+/-12.4% of the control value in the ACB, 37.9%+/-25.0% in the internal thoracic artery, and 21.2%+/-11.4% in the descending aorta-coronary bypass graft. The LVAD increased the diastolic flow by 97.7%+/-18.7% of the control value in the ACB, 64.5%+/-25.7% in the internal thoracic artery, and 63.0%+/-27.9% in the descending aorta-coronary bypass graft. The diastolic blood flows in the left anterior descending coronary artery and the three types of grafts were significantly greater with IABP than the control values, and significantly greater with LVAD than with IABP and the control values. The degrees of increase of diastolic flows in the left anterior descending coronary artery and the ACB with IABP and LVAD were significantly greater than in the arterial grafts (p < 0.01). The diastolic flows in the internal thoracic artery and descending aorta-coronary bypass graft increased less than in the native left anterior descending coronary artery and ACB during left ventricular assistance, particularly with IABP. It is important for the selection of tactics for the management of catastrophic status after coronary bypass grafting to consider the hemodynamic characteristics of the graft.
The relationship between ischaemia-modified albumin and good coronary collateral circulation.
Gök, Murat; Kundi, Harun; Kızıltunç, Emrullah; Topcuoglu, Canan; Ornek, Ender
2018-01-01
It is important to determine the grade of the coronary collateral circulation (CCC) in patients with stable coronary artery disease. In this study, we aimed to investigate the relationship between the ischaemia-modified albumin (IMA) level and good CCC. A total of 95 patients with coronary angiography and at least one epicardial coronary artery obstruction were included in the study. The Rentrop classification was used with CCC grading, where 0 and 1 were defined as poor collateral, and 2 and 3 were defined as good collateral. The IMA level of the patients was measured using an enzyme-linked immunosorbent assay (ELISA). The receiver-operating characteristic curve was used to show the sensitivity and specificity of IMA levels and the optimal cut-off value for predicting good CCC. The multiple logistic regression analysis revealed that the IMA level in the good CCC group was higher (p < 0.045). Conversely, the high-sensitivity C-reactive protein level was lower in the good CCC group (p < 0.023). We found an IMA cut-off value (4.7 ng/mL) that indicated good CCC level, and this shows good CCC with 70.2% sensitivity and 60.3% specificity. The IMA level could serve as a simple and useful predictor of well-developed CCC.
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1972-01-01
An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.
In vitro evaluation of the effect of aortic compliance on pediatric intra-aortic balloon pumping.
Minich, L L; Tani, L Y; Hawkins, J A; Bartkowiak, R R; Royall, M L; Pantalos, G M
2001-04-01
OBJECTIVES: To evaluate the effect of aortic compliance on pediatric intra-aortic balloon pumping (IABP). DESIGN: In vitro study using a mechanical model of the pediatric left heart circulation. SETTING: Cardiovascular fluid dynamics research laboratory. SUBJECT: Pulsatile flow system simulating the pediatric left heart circulation and two different aortas with compliances comparable to those of the pediatric aorta (0.12 and 0.07 mL/mm Hg). INTERVENTIONS: Measurements were made at a baseline peak aortic flow of 4 L/min, at simulated shock (1.7 L/min), and with 1:1 IABP (rates, 130 and 150 bpm; balloon volumes, 2.5 and 5.0 mL). MEASUREMENTS AND MAIN RESULTS: Peak flow rates were measured in the ascending aorta, coronary arterial system, and brachiocephalic arterial systems. Aortic pressure was measured in the ascending aorta. For both aortas (0.12 and 0.07 mL/mm Hg), IABP resulted in diastolic augmentation (38 +/- 8 and 43 +/- 16 mm Hg) and afterload reduction (4 +/- 2 and 6 +/- 3 mm Hg). For both aortas, compared to shock, IABP resulted in significant increases in coronary arterial and brachiocephalic arterial flow and aortic pressure for both aortas. Aortic flow significantly increased only in the less-compliant aorta. CONCLUSIONS: In a laboratory model of pediatric left heart circulation, IABP results in diastolic augmentation, afterload reduction, and improved hemodynamics, even in aortas of greater compliance.
Coronary revascularization in Japan. Part 2: comparison of facilities between 1997 and 1999.
Tsuchihashi, M; Tsutsui, H; Shihara, M; Shigematsu, H; Yamamoto, S; Koike, G; Kono, S; Takeshita, A
2001-12-01
A nation-wide survey on the procedures and facilities of coronary revascularization, percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) conducted by the Japanese Coronary Intervention Study (JCIS) group during 1997 revealed that PCI is more often used than CABG and is mainly carried out in low-volume facilities without surgical backup. The present study aimed to investigate the temporal changes in the usage of revascularization therapies and facilities from 1997 to 1999. A questionnaire was mailed in 1998 to the delegates of 1,086 PCI and 582 CABG facilities identified by the previous survey, and 89% of PCIs surveyed and 94% of CABGs surveyed reported back. The number of PCI procedures had increased by 19% from 97,831 to 116,479 and that of CABG procedures also increased by 21% from 16,374 to 19,846. The ratio of PCI to CABG was 5.9 in 1999, showing no significant change from 6.0 in 1997. In parallel, the number of PCI and CABG facilities increased from 888 to 941 and from 442 to 453, respectively. The use of coronary stents and other interventional devices increased during these 2 years. Coronary stents were used regardless of the annual procedural volume of the facilities, whereas other interventional devices, directional and rotational coronary atherectomy, were used mainly in the high-volume laboratories (p<0.01). Beating-heart, off-pump CABG had increased from 2% to 11% of total cases. Continued monitoring of trends in PCI and CABG facilities and procedures will be needed for nation-wide assessment of the use of new technology.
Vaidyanathan, Swaminathan; Kothandam, Sivakumar; Kumar, Rajesh; Indrajith, Sujatha Desai; Agarwal, Ravi
2017-01-01
A 26-year-old lady presented with exertional dyspnea, palpitations, central cyanosis, and oxygen saturations of 80% in room air. Her electrocardiogram, echocardiogram, and cardiac magnetic resonance were diagnostic of arrhythmogenic right ventricular dysplasia. There was no documented ventricular arrhythmia or syncopal episodes and Holter recordings were repeatedly normal. Cardiac hemodynamics showed right to left shunt through atrial septal defect, low pulmonary blood flow, normal atrial pressures, and minimally elevated right ventricular end-diastolic pressures. Since her presenting symptoms and cyanosis were attributed to reduced pulmonary blood flow, she underwent off-pump cavopulmonary anastomosis between right superior vena cava and right pulmonary artery. As we intended to avoid the adverse effect of extracorporeal circulation on the myocardial function and pulmonary vasculature, we did not attempt to reduce the size of the atrial septal defect. Her postoperative period was uneventful; oxygen saturation improved to 89% with significant improvement in effort tolerance. At 18-month follow-up, there were no ventricular arrhythmias on surveillance. The clinical presentation of this disease may vary from serious arrhythmias warranting defibrillators and electrical ablations at one end to right ventricular pump failure warranting cardiomyoplasty or right ventricular exclusion procedures at the other end. However, when the presentation was unusual with severe cyanosis through a stretched foramen ovale leading to reduced pulmonary blood flows, Glenn shunt served as a good palliation and should be considered as one of the options in such patients.
Ferrari, Gianfranco; Khir, Ashraf W; Fresiello, Libera; Di Molfetta, Arianna; Kozarski, Maciej
2011-09-01
We investigated the effects of the intra-aortic balloon pump (IABP) on endocardial viability ratio (EVR), cardiac output (CO), end-systolic (V(es)) and end-diastolic (V(ed)) ventricular volumes, total coronary blood flow (TCBF), and ventricular energetics (external work [EW], pressure-volume area [PVA]) under different ventricular (E(max) and diastolic stiffness) and circulatory (arterial compliance) parameters. We derived a hybrid model from a computational model, which is based on merging computational and hydraulic submodels. The lumped parameter computational submodel consists of left and right hearts and systemic, pulmonary, and coronary circulations. The hydraulic submodel includes part of the systemic arterial circulation, essentially a silicone rubber tube representing the aorta, which contains a 40-mL IAB. EVR, CO, V(es), and V(ed), TCBF and ventricular energetics (EW, PVA) were analyzed against the ranges of left ventricular E(max) (0.3-0.5-1 mm Hg/cm(3)) and diastolic stiffness V(stiffness) (≈0.08 and ≈0.3 mm Hg/cm(3), obtained by changing diastolic stiffness constant) and systemic arterial compliance (1.8-2.5 cm(3)/mm Hg). All experiments were performed comparing the selected variables before and during IABP assistance. Increasing E(maxl) from 0.5 to 2 mm Hg/cm(3) resulted in IABP assistance producing lower percentage changes in the selected variables. The changes in ventricular diastolic stiffness strongly influence both absolute value of EVR and its variations during IABP (71 and 65% for lower and higher arterial compliance, respectively). V(ed) and V(es) changes are rather small but higher for lower E(max) and higher V(stiffness). Lower E(max) and higher V(stiffness) resulted in higher TCBF and CO during IABP assistance (∼35 and 10%, respectively). The use of this hybrid model allows for testing real devices in realistic, stable, and repeatable circulatory conditions. Specifically, the presented results show that IABP performance is dependent, at least in part, on left ventricular filling, ejection characteristics, and arterial compliance. It is possible in this way to simulate patient-specific conditions and predict the IABP performance at different values of the circulatory or ventricular parameters. Further work is required to study the conditions for heart recovery modeling, baroreceptor controls, and physiological feedbacks. © 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Soh, S; Song, J W; Shim, J K; Kim, J H; Kwak, Y L
2016-10-01
Acute kidney injury (AKI) is a common morbidity after off-pump coronary revascularization. We investigated whether perioperative administration of sodium bicarbonate, which might reduce renal injury by alleviating oxidative stress in renal tubules, prevents postoperative AKI in off-pump coronary revascularization patients having renal risk factors. Patients (n=162) having at least one of the following AKI risk factors were enrolled: (i) age >70 yr; (ii) diabetes mellitus; (iii) chronic renal disease; (iv) congestive heart failure or left ventricular ejection fraction <35%; and (v) reoperation or emergency. Patients were evenly randomized to receive either sodium bicarbonate (0.5 mmol kg -1 for 1 h upon induction of anaesthesia followed by 0.15 mmol kg -1 h -1 for 23 h) or 0.9% saline. Acute kidney injury within 48 h after surgery was assessed using the Acute Kidney Injury Network criteria. The incidences of AKI were 21 and 26% in the bicarbonate and control groups, respectively (P=0.458). Serially measured serum creatinine concentrations and perioperative fluid balance were also comparable between the groups. The length of postoperative hospitalization and incidence of morbidity end points were similar between the groups, whereas significantly more patients in the bicarbonate group required prolonged mechanical ventilation (>24 h) relative to the control group (20 vs 6, P=0.003). Perioperative sodium bicarbonate administration did not decrease the incidence of AKI after off-pump coronary revascularization in high-risk patients and might even be associated with a need for prolonged ventilatory care. NCT01840241. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
MedlinePlus Videos and Cool Tools
As the heart pumps, the arteries carry oxygen-rich blood (shown in red) away from the heart and toward the body's tissues and vital organs. ... brain, liver, kidneys, stomach, and muscles, including the heart muscle itself. At the same time, the veins ...
Lift-Off Performance in Flexure Pivot Pad and Hybrid Bearings
2008-12-01
and Dawson, M. P., 1998, "Experience in the Use of Flexure Pivot Tilt Pad Bearings in Boiler Feed Water Pumps ," Proc. of the 15th International...freely. Test Procedure 1) Turn on the pump to buffer water to the test bearing. 2) Turn on air to the air seal that prevents water flowing... Pump Users Symposium, Turbomachinery Laboratory, College Station, Texas, pp. 77-84. [6] Rodriguez, L., 2004, “Experimental Frequency-Dependent
Investigation of an ejector heat pump by analytical methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, C.T.
1984-07-01
Using existing theories of ejector design, the optimum geometry of a high-efficiency ejector - including mixing section cross-sectional area, mass flow entrainment rate, ejector efficiency, and overall COP - for a heat pump cycle was determined. A parametric study was performed to evaluate the COP values for different operating conditions. A sensitivity study determined th effects of nozzle efficiency and diffuser efficiency on the overall ejector heat pump COP. The off-design study estimated the COP for an ejector heat pump operating at off-design conditions. Refrigerants 11, 113, and 114 are three of the halocarbons which best satisfy the criteria formore » an ejector heat pump system. The estimated COPs were 0.3 for the cooling mode and 1.3 for the heating mode at standard operating conditions: a boiler temperature of 93.3/sup 0/C (200/sup 0/F), a condenser temperature of 43.3/sup 0/C (110/sup 0/F), and an evaporator temperature of 10/sup 0/C (50/sup 0/F). Based on the same operating conditions, an optimum ejector geometry was estimated for each of the refrigerants R-11 and R-113. Since the COP values for heating obtained in this analysis are greater than unity, the performance of an ejector heat pump operating in the heating mode should be competitive with that of oil- or gas-fired furnaces or electrical resistance heaters.« less
1981-09-28
hypertension (Finch and Leach, 1970; Haeusler et al. 1972) depending on whether the peripheral or the central sympathetic nevous system was destroyed...Dissertation directed by: Motllal B. Pamnanl, M.D., Ph.D. Associate Professor, Department of Physiology The mechanism of the elevated systemic arterial...vascular Na"*"-K̂ pump activity and development of hypertension; and 4) investigate the role of the sympathetic nervous system and the AV3V region
Otsuka, Kenju; Chu, Shu-Chun
2013-05-01
We report a simple method for generating cylindrical vector beams directly from laser-diode (LD)-pumped microchip solid-state lasers by using dual end-pumping beams. Radially as well as azimuthally polarized vector field emissions have been generated from the common c-cut Nd:GdVO4 laser cavity merely by controlling the focus positions of orthogonally polarized LD off-axis pump beams. Hyperbolically polarized vector fields have also been observed, in which the cylindrical symmetry of vector fields is broken. Experimental results have been well reproduced by numerical simulations.
A stable submillimeter laser local oscillator for heterodyne radiometry and spectroscopy
NASA Technical Reports Server (NTRS)
Koepf, G. A.; Fetterman, H. R.; Mcavoy, N.
1980-01-01
A submillimeter laser with off-axis pump beam injection is described. This design concept achieves complete isolation of the pump laser with respect to the pump radiation reflected from the submillimeter resonator. Active line independent stabilization of the pump laser is obtained by the use of an external tunable etalon as a frequency reference. The submillimeter output power is constant to within 4% over periods of hours. Mean frequency drifts of less than 2 parts in 100 million per minute were measured by mixing with very high harmonics of an X-band synthesizer in a planar Schottky diode.
Erbium Doped GaN Lasers by Optical Pumping
2016-07-13
obtained via growth by hydride vapor phase epitaxy (HVPE) in conjunction with a laser-lift-off (LLO) process. An Er doping level of 1.4 × 10^20 atoms/cm3... conjunction with a laser-lift-off (LLO) 2 process. An Er doping level
Controlling signal transport in a carbon nanotube opto-transistor
NASA Astrophysics Data System (ADS)
Li, Jinjin; Chu, Yanhui; Zhu, Ka-Di
2016-11-01
With the highly competitive development of communication technologies, modern information manufactures place high importance on the ability to control the transmitted signal using easy miniaturization materials. A controlled and miniaturized optical information device is, therefore, vital for researchers in information and communication fields. Here we propose a controlled signal transport in a doubly clamped carbon nanotube system, where the transmitted signal can be controlled by another pump beam. Pump off results in the transmitted signal off, while pump on results in the transmitted signal on. The more pump, the more amplified output signal transmission. Analogous with traditional cavity optomechanical system, the role of optical cavity is played by a localized exciton in carbon nanotube while the role of the mechanical element is played by the nanotube vibrations, which enables the realization of an opto-transistor based on carbon nanotube. Since the signal amplification and attenuation have been observed in traditional optomechanical system, and the nanotube optomechanical system has been realized in laboratory, the proposed carbon nanotube opto-transistor could be implemented in current experiments and open the door to potential applications in modern optical networks and future quantum networks.
Resonantly cladding-pumped Yb-free Er-doped LMA fiber laser with record high power and efficiency.
Zhang, Jun; Fromzel, Viktor; Dubinskii, Mark
2011-03-14
We report the results of our power scaling experiments with resonantly cladding-pumped Er-doped eye-safe large mode area (LMA) fiber laser. While using commercial off-the-shelf LMA fiber we achieved over 88 W of continuous-wave (CW) single transverse mode power at ~1590 nm while pumping at 1532.5 nm. Maximum observed optical-to-optical efficiency was 69%. This result presents, to the best of our knowledge, the highest power reported from resonantly-pumped Yb-free Er-doped LMA fiber laser, as well as the highest efficiency ever reported for any cladding-pumped Er-doped laser, either Yb-co-doped or Yb-free.
Hall, Lawrence B.
1955-01-01
The new demands placed upon application equipment by the introduction of modern insecticides have revealed the deficiencies of this equipment when required for continuous use on a large scale. If adequate equipment is to be produced, specifications must be based not only on basic materials tests but also on “use” tests, in which the conditions of field use are simulated. The author outlines suggested techniques to be followed and standards to be adopted in testing the performance of compression sprayers and allied equipment, with reference to the following features: compression-sprayer tank fatigue; tank impact; pump resistance to bursting; pump resistance to collapse; pump friction; cut-off valve durability; constant-pressure valves; cut-off valve actuation; hose flexure; hose tension and bursting-pressure; hose friction; gaskets, valve faces, and similar non-metallic parts; nozzle-orifice erosion; and nozzle pattern. ImagesFIG. 1FIG. 14FIG. 20 PMID:14364189
NASA Astrophysics Data System (ADS)
Chu, Shu-Chun
2009-02-01
This paper introduces a scheme for generation of vortex laser beams from a solid-state laser with off-axis laser-diode pumping. The proposed system consists of a Dove prism embedded in an unbalanced Mach-Zehnder interferometer configuration. This configuration allows controlled construction of p × p vortex array beams from Ince-Gaussian modes, IGep,p modes. An incident IGe p,p laser beam of variety order p can easily be generated from an end-pumped solid-state laser with an off-axis pumping mechanism. This study simulates this type of vortex array laser beam generation and discusses beam propagation effects. The formation of ordered transverse emission patterns have applications in a variety of areas such as optical data storage, distribution, and processing that exploit the robustness of soliton and vortex fields and optical manipulations of small particles and atoms in the featured intensity distribution.
Analysis of Dual-Order Backward Pumping Schemes in Distributed Raman Amplification System
NASA Astrophysics Data System (ADS)
Singh, Kulwinder; Patterh, Manjeet Singh; Bhamrah, Manjit Singh
2018-04-01
Backward pumping in fiber Raman amplifiers has been investigated in this paper in terms of on-off Raman gain, noise figure and optical signal-to-noise ratio. The results exhibit that with four first-order pumps and one second-order pump scheme can be employed to achieve 8.2 dB noise figure in 64 channel fiber optic communication system. It has also been reported that 2.65 dB gain ripple, 0.87 dB noise figure tilt and 2.02 dB OSNR tilt can be attained with the second-order pumping in fiber Raman amplifiers. The main advantage of the scheme is that only 50 mW second-order pump shows appreciable improvement in the system performance. It shows that further increase in first-order and second-order pump powers increase system noise implications.
Compression therapy in mixed ulcers increases venous output and arterial perfusion.
Mosti, Giovanni; Iabichella, Maria Letizia; Partsch, Hugo
2012-01-01
This study was conducted to define bandage pressures that are safe and effective in treating leg ulcers of mixed arterial-venous etiology. In 25 patients with mixed-etiology leg ulcers who received inelastic bandages applied with pressures from 20 to 30, 31 to 40, and 41 to 50 mm Hg, the following measurements were performed before and after bandage application to ensure patient safety throughout the investigation: laser Doppler fluxmetry (LDF) close to the ulcer under the bandage and at the great toe, transcutaneous oxygen pressure (TcPo(2)) on the dorsum of the foot, and toe pressure. Ejection fraction (EF) of the venous pump was performed to assess efficacy on venous hemodynamics. LDF values under the bandages increased by 33% (95% confidence interval [CI], 17-48; P < .01), 28% (95% CI, 12-45; P < .05), and 10% (95% CI, -7 to 28), respectively, under the three pressure ranges applied. At toe level, a significant decrease in flux of -20% (95% CI, -48 to 9; P < .05) was seen when bandage pressure >41 mm Hg. Toe pressure values and TcPo(2) showed a moderate increase, excluding a restriction to arterial perfusion induced by the bandages. Inelastic bandages were highly efficient in improving venous pumping function, increasing the reduced ejection fraction by 72% (95% CI, 50%-95%; P < .001) under pressure of 21 to 30 mm Hg and by 103% (95% CI, 70%-128%; P < .001) at 31 to 40 mm Hg. In patients with mixed ulceration, an ankle-brachial pressure index >0.5 and an absolute ankle pressure of >60 mm Hg, inelastic compression of up to 40 mm Hg does not impede arterial perfusion but may lead to a normalization of the highly reduced venous pumping function. Such bandages are therefore recommended in combination with walking exercises as the basic conservative management for patients with mixed leg ulcers. Copyright © 2012 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.
Protective effect of active perfusion in porcine models of acute myocardial ischemia
Feng, Zanxiang; Mao, Zhifu; Dong, Shengjun; Liu, Baohui
2016-01-01
Mortality rates associated with off-pump coronary artery bypass (CAB) are relatively high, as the majority of patients requiring CAB are at a high risk for cardiac events. The present study aimed to establish porcine models of acute myocardial ischemia, and evaluate the protective role of shunt and active perfusion. A total of 30 pigs were randomly assigned to five groups, as follows: i) Sham (control); ii) A1 (shunt; stenosis rate, 55%); iii) A2 (shunt; stenosis rate, 75%); iv) B1 (active perfusion; stenosis rate, 55%); and v) B2 (active perfusion; stenosis rate, 75%) groups. Aortic pressure (P0), left anterior descending coronary pressure (P1), and coronary effective perfusion pressure (P1/P0) were measured. The expression levels of tumor necrosis factor-α (TNF-α), cardiac troponin (cTnI), creatine kinase-myocardial band (CK-MB), interleukin (IL)-6, IL-10, B-cell lymphoma 2 (Bcl-2), and caspase-3 were detected using enzyme-linked immunosorbent assay or western blotting. The myocardial apoptosis rate was determined using the terminal deoxynucleotidyl transferase dUTP nick end labeling assay. Ischemia models with stenosis rates of 55 and 75% were successfully constructed following suturing of the descending artery. Compared with the control, the 55 and 75% stenosis groups demonstrated significantly decreased P1/P0, increased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, an increased rate of myocardial apoptosis, and a decreased expression level of anti-apoptotic protein, Bcl-2. At 30 min following successful establishment of the model (ST segment elevation to 1 mm), group B demonstrated significantly increased P1/P0, decreased expression levels of TNF-α, cTnI, CK-MB, IL-6, IL-10 and caspase-3, a decreased rate of myocardial apoptosis, and an increased expression level of anti-apoptotic protein, Bcl-2. Furthermore, the current study indicated that active perfusion was more efficacious in maintaining myocardial perfusion and alleviating ischemic injury when compared with traditional shunt perfusion. PMID:27573177
[Peripheral vascular injuries in polytrauma].
Richter, A; Silbernik, D; Oestreich, K; Karaorman, M; Storz, L W
1995-09-01
Between 1972 und 1993 a total of 68 patients were treated at the Department of Surgery of the University Clinic of Mannheim for peripheral vascular injury resulting from multiple trauma. The average age of these patients was 31.3 years, and most of them were male (88.2%; n = 60). The injured vessels were localized evenly in all the extremities: 31 patients (45.5%) presented with arterial damage of the upper extremity, and 37 (54.5%) showed lesions along the femoro-popliteal arteries. The most frequent location of injured vessels in the multiply traumatized patient was the popliteal artery (n = 18, 26.5%), the distal part of the superficial femoral artery (n = 12, 17.6%), the brachial artery (n = 14, 20.6%) and the axillary artery (n = 10, 14.6%). The dominant cause, of trauma was road traffic accidents (72%), and 20 patients (29%) acquired their vascular injuries as motorcyclists. There were also 13 occupational accidents (19%) involving vascular injuries. In addition to a vascular trauma 34 patients (50%) had complicated fractures, and a further 34 patients (50%) had multiple fractures: 12 (17.6%) had head and brain damage, 5 (7.3%) had blunt abdominal trauma and 6 (8.8%) had blunt thoracic injury. The general amputation rate was 2.9% (n = 2). One patient died on the table of a torn off subclavian artery combined with multiple other injuries. Paresis of the plexus is a particular problem after vascular lesions of the upper extremity: in 22 patients (71%) paresis of the plexus persisted after successful vascular reconstruction (follow-up period between 3 months and 16 years, median time 3.45 years).(ABSTRACT TRUNCATED AT 250 WORDS)
Osawa, Kazuhiro; Nakanishi, Rine; Miyoshi, Toru; Rahmani, Sina; Ceponiene, Indre; Nezarat, Negin; Kanisawa, Mitsuru; Qi, Hong; Jayawardena, Eranthi; Kim, Nicholas; Ito, Hiroshi; Budoff, Matthew J
2018-04-26
Increased arterial stiffness is reportedly associated with cardiac remodelling, including the left atrium and left ventricle, in middle-aged and older adults. However, little is known about this association in young adults. In total, 73 patients (44 (60%) men) aged 25 to 45 years with suspected coronary artery disease were included in the analysis. The left atrial volume index (LAVI), left ventricular volume index (LVVI), and left ventricular mass index (LVMI) were measured using coronary computed tomography angiography (CCTA). Arterial stiffness was assessed with the cardio-ankle vascular index (CAVI). An abnormally high CAVI was defined as that above the age- and sex-specific cut-off points of the CAVI. Compared with patients with a normal CAVI, those with an abnormally high CAVI were older and had a greater prevalence of diabetes mellitus, higher diastolic blood pressure, greater coronary artery calcification score, and a greater LAVI (33.5±10.3 vs. 43.0±10.3mL/m 2 , p <0.01). In contrast, there were no significant differences in the LVVI or LVMI between the subgroups with a normal CAVI and an abnormally high CAVI. Multivariate linear regression analysis showed that the LAVI was significantly associated with an abnormally high CAVI (standardised regression coefficient=0.283, p=0.03). The present study demonstrated that increased arterial stiffness is associated with the LAVI, which reflects the early stages of cardiac remodelling, independent of various comorbidity factors in young adults with suspected coronary artery disease. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
Screening of depression in cardiology: A study on 617 cardiovascular patients.
Tesio, Valentina; Marra, Sebastiano; Molinaro, Stefania; Torta, Riccardo; Gaita, Fiorenzo; Castelli, Lorys
2017-10-15
Depression screening in the cardiovascular disease (CVD) care setting is under-performed, also because the issue of the optimal screening tools cut-off is still open. We analysed which HADS (Hospital Anxiety and Depression Scale) total score cut-off value shows the best properties in two groups of 357 Acute Coronary Syndrome (ACS) and 260 Chronic Coronary Artery Disease (CAD) hospitalized patients. A Receiver Operating Characteristics (ROC) curve was plotted for both groups using the Montgomery-Asberg Depression Rating Scale (MADRS) as the criterion. Accuracy, positive (PPV) and negative (NPV) predictive values were computed for different cut-off scores. The ROC curves confirmed the excellent/very good accuracy of the HADS in both groups, with an area under the curve of 0.911 for the ACS and 0.893 for the CAD patients. The cut-off of 14 showed the best compromise between high sensitivity and good specificity in both groups, with high negative predicted values (95.5% and 92.4%, respectively). Using a cut-off value of 14, the HADS could be considered a good screening tool to identify hospitalized CAD and ACS patients requiring a more accurate depression assessment, in order to promptly plan the most appropriate treatment strategies and prevent the negative effects of depression in CVD patients. Copyright © 2017 Elsevier B.V. All rights reserved.
Jantosovicová, J; Jantosovic, J
1983-01-01
To study the vascularization of the testis of stallions we used 96 testes. We examined its topography and anatomy by roentgenography, stereoroentgenography, by the corosive method, and by means of gel and China ink injections. To make the roentgeno-arteriograms we used minimum emulsified in glycerine as contrast medium. The branching off of the Aa. testiculares from the Aorta abdominalis is variable in stallions. We observed also a peculiar age-dependent arrangement of the loops of the convolution. In the adult stallion, the shape of the convolution is either cylindrical or conical, spindle-shaped, or irregular. Bifurcation of the A. testicularis before entering the testis did not occur. The epididymical arteries arise either from the convolution or from the Pars recta a. testicularis. They may ramify from a common branch near the origine of A. testicularis. We found regular, direct anastomoses between A. epididymidis cranialis and the branches from the Rr. testiculares. Pars marginalis a. testicularis bifurcates at the transition plane of Margo epididymidis and Margo liber, eventually in the middle 1/3 of Margo epididymidis. Rr. testiculares run parallelly along the Margo liber and give off a number of verically arising branches. The Aa. radiatae centripetales run to the Mediastinum testis without giving off branches. We have not found any anstomoses between the centripetal arteries or the centripetal and centrifugal ones. The A. ductus deferentis is just as thick as the branches from the A. epididymidis caudalis. The lumina of the A. cremasterica is 0.5 to 1 mm. We did not succeed in filling it up reversely through the A. epididymidis caudalis. The artery anastomoses with A. ductus deferentis and A. epididymidis caudalis.
Katlandur, Hüseyin; Ulucan, Şeref; Özdil, Hüseyin; Keser, Ahmet; Kaya, Zeynettin; Özbek, Kerem; Ülgen, M Sıddık
2016-11-01
The association between epicardial fat thickness (EFT) and positive exercise test results for the diagnosis of coronary artery diseases (CAD) has yet to be evaluated. This study assessed the predictive value of EFT for CAD on the angiographs of patients with positive exercise tests. A total of 91 subjects were chosen consecutively from stable angina pectoris patients who were referred for coronary angiography due to a positive exercise test result. The EFT measures were obtained by echocardiographic parasternal long-axis views on the free wall of the right ventricle at end-systole of three cardiac cycles. Gensini scores were calculated by a conventional coronary angiography technique using a calculation method previously defined. Receiver operator characteristic (ROC) curve analysis revealed a 0.65 cm (95% confidence interval: 0.628, 0.832, p < 0.001) area under the curve with 74.3% sensitivity and 62.3% specificity at the cut-off value of EFT for the prediction of critical coronary artery stenosis. Following ROC curve analysis, two groups were defined according to EFT cut-off value (groups 1 and 2). The severe coronary stenosis ratio was significantly higher in group 2 compared to group 1 (31.9 % vs. 11%, p < 0.001) and Gensini scores were significantly higher in group 2 (6.3 ± 13.3 vs. 16.5 ± 17.9; p < 0.001). There was no significant correlation between Gensini scores and EFT in group 1 (r = 0.093, p = 0.549), but there was a strong significant correlation in group 2 (r = 0.730, p < 0.001). Linear multivariate regression analysis revealed that EFT (> 0.65 cm) was the only independent risk factor for critical coronary artery stenosis (β = 0.451, p < 0.001). EFT was significantly correlated with the severity and prevalence of coronary artery disease in positive exercise test patients.
Zero Gravity Cryogenic Vent System Concepts for Upper Stages
NASA Technical Reports Server (NTRS)
Flachbart, Robin H.; Holt, James B.; Hastings, Leon J.
1999-01-01
The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray bar system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy is required. a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point. the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating, boil-off losses.
Zero Gravity Cryogenic Vent System Concepts for Upper Stages
NASA Technical Reports Server (NTRS)
Flachbart, Robin H.; Holt, James B.; Hastings, Leon J.
2001-01-01
The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses.
Stress Introduction Rate Alters the Benefit of AcrAB-TolC Efflux Pumps.
Langevin, Ariel M; Dunlop, Mary J
2018-01-01
Stress tolerance studies are typically conducted in an all-or-none fashion. However, in realistic settings-such as in clinical or metabolic engineering applications-cells may encounter stresses at different rates. Therefore, how cells tolerate stress may depend on its rate of appearance. To address this, we studied how the rate of stress introduction affects bacterial stress tolerance by focusing on a key stress response mechanism. Efflux pumps, such as AcrAB-TolC of Escherichia coli , are membrane transporters well known for the ability to export a wide variety of substrates, including antibiotics, signaling molecules, and biofuels. Although efflux pumps improve stress tolerance, pump overexpression can result in a substantial fitness cost to the cells. We hypothesized that the ideal pump expression level would involve a rate-dependent trade-off between the benefit of pumps and the cost of their expression. To test this, we evaluated the benefit of the AcrAB-TolC pump under different rates of stress introduction, including a step, a fast ramp, and a gradual ramp. Using two chemically diverse stresses, the antibiotic chloramphenicol and the jet biofuel precursor pinene, we assessed the benefit provided by the pumps. A mathematical model describing these effects predicted the benefit as a function of the rate of stress introduction. Our findings demonstrate that as the rate of introduction is lowered, stress response mechanisms provide a disproportionate benefit to pump-containing strains, allowing cells to survive beyond the original inhibitory concentrations. IMPORTANCE Efflux pumps are ubiquitous in nature and provide stress tolerance in the cells of species ranging from bacteria to mammals. Understanding how pumps provide tolerance has far-reaching implications for diverse fields, from medicine to biotechnology. Here, we investigated how the rate of stressor appearance impacts tolerance. We focused on two distinct substrates of AcrAB-TolC efflux pumps, the antibiotic chloramphenicol and the biofuel precursor pinene. Interestingly, tolerance is highly dependent on the rate of stress introduction. Therefore, it is important to consider not only the total quantity of a stressor but also the rate at which it is applied. The implications of this work are significant because environments are rarely static; antibiotic concentrations change during dosing, and metabolic engineering processes change with time. Copyright © 2017 American Society for Microbiology.
Gadhinglajkar, Shrinivas; Sreedhar, Rupa; Karunakaran, Jayakumar; Misra, Manoranjan; Somasundaram, Ganesh; Mathew, Thomas
2010-01-01
A pacing system infection may lead to infective endocarditis and systemic sepsis. Tricuspid valve surgery may be required if the valve is severely damaged in the process of endocarditis. Although, cardiopulmonary bypass is the safe choice for performing right-heart procedures, it may carry risk of inducing systemic inflammatory response and multi-organ dysfunction. Some studies have advocated TV surgery without institution of CPB. We report tricuspid valve excision using the off-pump inflow occlusion technique in a 68-year-old man. We also describe role of intra-operative TEE as a monitoring tool at different stages of the surgical procedure.
Evaluation of mitral valve replacement anchoring in a phantom
NASA Astrophysics Data System (ADS)
McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.
2012-02-01
Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.
Daley, Kelly B; Wodrich, David L; Hasan, Khalid
2006-02-01
To determine whether stabilizing serum glucose, via introduction of an insulin pump, improves classroom attention among children with type-1 diabetes mellitus. Four boys having type-1 diabetes mellitus with unstable serum glucose were observed in their classroom for 10 baseline days. An insulin pump was placed and serum glucose stabilized, and they were then observed again for 10 days. A modified multiple baseline design was used to determine if improved on-task and off-task behavior was associated with better glycemic control. Rating scales and a laboratory measure of attention, measures of secondary interest, were also administered before and after pump introduction, and potential improvement in individuals' scores was evaluated. All boys had apparent improvement in on-task and off-task behavior as observed in their classrooms. Improvements were substantial, averaging 20% in on-task behavior and 34% in off-task behavior. However, no changes were detected on rating scales or laboratory measures. This study offers preliminary evidence that stabilizing serum glucose improves classroom attention, although the effect was detected only by observation of classroom behavior using highly structured techniques. Consequently, use of direct observation techniques may be important in studying the effects of chronic illness on classroom functioning.
Hernandez-Suarez, Dagmar F; Scott, Stuart A; Tomey, Matthew I; Melin, Kyle; Lopez-Candales, Angel; Buckley, Charlotte E; Duconge, Jorge
2017-09-01
Clopidogrel is by far the most prescribed platelet adenosine diphosphate (ADP) antagonist in Puerto Rico despite the advent of newer agents (prasugrel and ticagrelor). Given the paucity of data on clopidogrel responsiveness in Hispanics, we sought to determine the association between clinical characteristics and platelet reactivity in Puerto Rican patients on clopidogrel therapy. A total of 100 Puerto Rican patients on clopidogrel therapy were enrolled and allocated into two groups: Group I, without high on-treatment platelet reactivity (HTPR); and Group II, with HTPR. Platelet function was measured ex vivo using the VerifyNow® P2Y12 assay. The cohort was comprised of Hispanic patients with coronary artery disease (57%), peripheral artery disease (32%), carotid artery stenosis (7%), cerebral artery aneurysm (2%), and stroke (2%). Mean platelet reactivity was 200 ± 61 P2Y12 reaction units (PRUs) (range: 8-324), and 35% of patients had HTPR (PRUs ⩾ 230). Multivariable logistic regression analysis determined that diabetes mellitus (DM) [odds ratio (OR) = 3.27; 95% confidence interval (CI): 1.20-8.96], use of proton-pump inhibitors (PPIs) (OR = 3.60; 95% CI: 1.09-11.82), and calcium channel blockers (CCBs) (OR = 3.10; 95% CI: 1.09-8.83) were independent predictors of HTPR ( p < 0.05) after adjusting for other clinical variables. In a sample of 100 Puerto Rican Hispanic patients on clopidogrel, 35% had HTPR. Furthermore, DM, PPIs and CCBs predicted HTPR. Clinical outcome data are needed to identify appropriate PRU thresholds for risk prediction in the Puerto Rican population.
Drug utilization and off-label drug use in Spanish pediatric gastroenterology outpatients.
Ruíz-Antorán, Belén; Piñeiro, Roi; Avendaño, Cristina; Román, Enriqueta; Cilleruelo, María Luz; Gutiérrez-Junquera, Carolina; Centeno, Gustavo; Cilleruelo, María José
2013-02-01
The clinical use of medicines outside the conditions authorized in their Summary of Product Characteristics (SPC) (off-label use) is a common practice in pediatrics. The aim of the present study was to describe and quantify the medicines received by children attended in the pediatric gastroenterology department, their off-label use, and compliance with accepted rules for said use. A retrospective observational study was performed on all of the patients who had their first consultation in pediatric gastroenterology between January 1 and October 31, 2010. All of the clinical information and medicines prescribed were analyzed. Off-label use was defined as the use of medicines in indications not included in the officially approved SPC or in ages not included or recommended in the SPC as well as the use of doses, intervals, or administration routes different from those considered in the SPC. A total of 695 patients (52.8% male) were included, 48.2% younger than 2 years. Two-hundred seven patients (29.8%) received 331 prescriptions. The most commonly used medicines were anti-H2 and proton pump inhibitors. Of all the prescriptions, 33.2% were considered off-label, and up to 47.3% of the prescribed patients had at least 1 medicine under off-label conditions. The medical records contained no documentation on information given to the parents regarding off-label use. The study found a high percentage of off-label use of medicines in the Pediatric Gastroenterology outpatient setting, especially in children younger than 2 years. Several initiatives were derived from the present study and implemented in our hospital.
Primary Intravenous Set Consumption Across 3 Branded Infusion Pumps
Hedlund, Nancy; Sarangpur, Shishir; Kayler, Shannon; O'Brien, Kathy
2017-01-01
This retrospective study of 6426 hip replacement, coronary artery bypass graft, and colectomy surgeries across 23 US hospitals found that intravenous (IV) set designs that can be interchanged for use both in gravity-fed and automated pump delivery systems are replaced less frequently than IV sets designed for use primarily by one delivery method. Semistructured interviews with nurses highlighted the impact of set design on nursing workflow when moving between gravity-fed and pump-based administration. Use of interchangeable, single-design IV sets across gravity and automated infusions minimizes disruptions to closed systems, may reduce nurses being distracted from patients' clinical needs when replacing sets, and may yield supply cost savings. PMID:28682999
Okita, Yutaka; Matsumori, Masamichi; Kano, Hiroya
2016-04-01
The cases of 3 patients with brain malperfusion secondary to acute aortic dissection who underwent preoperative perfusion of the right common carotid artery are presented. The patients were 64, 65 and 72 years old and 2 were female. All were in a comatose or semi-comatose state with left hemiplegia. The right common carotid artery was exposed and directly cannulated, using a 12-Fr paediatric arterial cannula. The right common femoral artery was chosen for arterial drainage, using a 14-Fr double-lumen cannula. The circuit contained a small roller pump and heat exchanger coil. Target flow was set at 90 ml/min and blood temperature at 30 °C. Durations of right carotid perfusion were 120, 100 and 45 min, respectively. All underwent partial arch replacement and survived. Postoperative neurological sequelae were minimal in all cases. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
NASA Astrophysics Data System (ADS)
Dhanasekaran, A.; Kumaraswamy, S.
2018-01-01
Pressure pulsation causes vibration in the Electric Submersible Pump (ESP) and affects the life and performance of its system. ESP systems are installed at depths ranging from a few meters to several hundred meters. Unlike pumps used on the surface, once they are installed they become inaccessible for maintenance or for any kind of diagnostic measurement that might be taken directly on them. Therefore a detailed knowledge of mean and fluctuating pressures is required to achieve an optimal pressure distribution inside the ESP. This paper presents the results of an experimental investigation of the stage-wise pulsating pressure in ESP at shut-off condition at different speeds. Experiments were conducted on a pump having five stages. A variable frequency drive was used to operate the pump at five different speeds. Piezoresistive transducers were mounted at each stage of ESP to capture the unsteady pressure signals. Fast Fourier Transformation was carried out on the pressure signals to convert into frequency domain and the spectra of pressure pulsation signals were analyzed. The obtained results indicated the existence of fundamental frequency corresponding to the speed of rotation times the number of impeller blades and of the whole series of harmonics of higher frequencies.
Sung, Hea Jung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye
2012-01-01
Background/Aims Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. Methods We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. The characteristics of acid and weakly acidic reflux were evaluated. Symptomatic and asymptomatic reflux were compared according to GERD subtypes and individual symptoms. Results Forty-two patients (22 males, mean age 46 years) were diagnosed as GERD (17 erosive reflux disease, 9 pH(+) non-erosive reflux disease [NERD], 9 hypersensitive esophagus and 7 symptomatic NERD). A total of 1,725 reflux episodes were detected (855 acid [50%], 857 weakly acidic [50%] and 13 weakly alkaline reflux [< 1%]). Acid reflux was more frequently symptomatic and bolus clearance was longer compared with weakly acidic reflux. In terms of globus, weakly acidic reflux was more symptomatic. Symptomatic reflux was more frequently acid and mixed reflux; these associations were more pronounced in erosive reflux disease and symptomatic NERD. The perception of regurgitation was related to acid reflux, while that of globus was more related to weakly acidic reflux. Conclusions In patients not taking PPI, acid reflux was more frequently symptomatic and had longer bolus clearance. Symptomatic reflux was more frequently acid and mixed type; however, weakly acidic reflux was associated more with globus. These data suggest a role for impedance-pH data in the evaluation of globus. PMID:22837877
Sung, Hea Jung; Cho, Yu Kyung; Moon, Sung Jin; Kim, Jin Su; Lim, Chul Hyun; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Myung-Gye
2012-07-01
Available data about reflux patterns and symptom determinants in the gastroesophageal reflux disease (GERD) subtypes off proton pump inhibitor (PPI) therapy are lacking. We aimed to evaluate reflux patterns and determinants of symptom perception in patients with GERD off PPI therapy by impedance-pH monitoring. We retrospectively reviewed the impedance-pH data in patients diagnosed as GERD based on results of impedance-pH monitoring, endoscopy and/or typical symptoms. The characteristics of acid and weakly acidic reflux were evaluated. Symptomatic and asymptomatic reflux were compared according to GERD subtypes and individual symptoms. Forty-two patients (22 males, mean age 46 years) were diagnosed as GERD (17 erosive reflux disease, 9 pH(+) non-erosive reflux disease [NERD], 9 hypersensitive esophagus and 7 symptomatic NERD). A total of 1,725 reflux episodes were detected (855 acid [50%], 857 weakly acidic [50%] and 13 weakly alkaline reflux [< 1%]). Acid reflux was more frequently symptomatic and bolus clearance was longer compared with weakly acidic reflux. In terms of globus, weakly acidic reflux was more symptomatic. Symptomatic reflux was more frequently acid and mixed reflux; these associations were more pronounced in erosive reflux disease and symptomatic NERD. The perception of regurgitation was related to acid reflux, while that of globus was more related to weakly acidic reflux. In patients not taking PPI, acid reflux was more frequently symptomatic and had longer bolus clearance. Symptomatic reflux was more frequently acid and mixed type; however, weakly acidic reflux was associated more with globus. These data suggest a role for impedance-pH data in the evaluation of globus.
Hong, Sung-Jin; Ko, Young-Guk; Shin, Dong-Ho; Kim, Jung-Sun; Kim, Byeong-Keuk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo
2015-03-01
This study sought to compare the outcomes of spot stenting versus long stenting after intentional subintimal approach for long femoropopliteal chronic total occlusions (CTO). The optimal stenting strategy following the subintimal recanalization of long femoropopliteal chronic total occlusions has not been investigated. A total of 196 limbs in 163 patients, implanted with bare nitinol stents after subintimal approach in long femoropopliteal occlusions (lesion length 25 ± 8 cm), were retrospectively analyzed. The primary patency was compared between spot stenting (n = 129) and long stenting (n = 67). Baseline characteristics and immediate procedural results were similar between groups. Adjusted-primary patency (47% vs. 77%, p < 0.001) and adjusted-freedom from target lesion revascularization (52% vs. 84%, p < 0.001) at 2 years were significantly lower in the long stenting group than in the spot stenting group. The incidence of stent fracture, fracture type, and restenosis pattern did not differ between groups. Long stenting was an independent predictor of restenosis (hazard ratio [HR]: 2.0) along with other risk factors such as nonuse of clopidogrel (HR: 3.3) or cilostazol (HR: 2.2), small stent diameter (HR: 0.6), poor run-off (HR: 1.9), and post-procedural ankle-brachial index (HR: 0.1). Compared with spot stenting after adjustment using inverse probability of treatment weighting, long stenting, especially involving the P2 or P3 segment of the popliteal artery, was independently associated with 7.5-fold increases in restenosis risk (p < 0.001). The primary patency was significantly higher with spot stenting than with long stenting following subintimal approach for long femoropopliteal chronic total occlusions. The risk of restenosis was especially higher when long stenting was extended to the distal popliteal artery. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Yakun; Tao, Rumao; Su, Rongtao; Wang, Xiaolin; Ma, Pengfei; Zhang, Hanwei; Zhou, Pu; Si, Lei
2018-04-01
This paper presents an investigation of the effect of pump wavelength drift on the threshold of mode instability (MI) in high-power ytterbium-doped fiber lasers. By using a semi-analytical model, we study the effects of pump wavelength drift with a central pump wavelength around 976 nm and 915 nm, respectively. The influences of the pump absorption coefficient and total pump absorption are considered simultaneously. The results indicate that the effect of pump wavelength drift around 976 nm is stronger than that around 915 nm. For more efficient suppression of MI by shifting the pump wavelength, efficient absorption of pump power is required. The MI thresholds for fibers with different total pump absorptions and cladding diameters are compared. When the total pump absorption is increased, the gain saturation is enhanced, which results in the MI being mitigated more effectively and being more sensitive to pump wavelength drift. The MI threshold in gain fibers with larger inner cladding diameter is higher but more dependent upon pump wavelength. The results of this work can help in optimizing the pump wavelength and fiber parameters and suppressing MI in high-power fiber lasers.
Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P
2012-09-01
This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Wave energy patterns of counterpulsation: a novel approach with wave intensity analysis.
Lu, Pong-Jeu; Yang, Chi-Fu Jeffrey; Wu, Meng-Yu; Hung, Chun-Hao; Chan, Ming-Yao; Hsu, Tzu-Cheng
2011-11-01
In counterpulsation, diastolic augmentation increases coronary blood flow and systolic unloading reduces left ventricular afterload. We present a new approach with wave intensity analysis to revisit and explain counterpulsation principles. In an acute porcine model, a standard intra-aortic balloon pump was placed in descending aorta in 4 pigs. We measured pressure and velocity with probes in left anterior descending artery and aorta during and without intra-aortic balloon pump assistance. Wave intensities of aortic and left coronary waves were derived from pressure and flow measurements with synchronization correction. We identified predominating waves in counterpulsation. In the aorta, during diastolic augmentation, intra-aortic balloon inflation generated a backward compression wave, with a "pushing" effect toward the aortic root that translated to a forward compression wave into coronary circulation. During systolic unloading, intra-aortic balloon pump deflation generated a backward expansion wave that "sucked" blood from left coronary bed into the aorta. While this backward expansion wave translated to reduced left ventricular afterload, the "sucking" effect resulted in left coronary blood steal, as demonstrated by a forward expansion wave in left anterior descending coronary flow. The waves were sensitive to inflation and deflation timing, with just 25 ms delay from standard deflation timing leading to weaker forward expansion wave and less coronary regurgitation. Intra-aortic balloon pumps generate backward-traveling waves that predominantly drive aortic and coronary blood flow during counterpulsation. Wave intensity analysis of arterial circulations may provide a mechanism to explain diastolic augmentation and systolic unloading of intra-aortic balloon pump counterpulsation. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Cavopulmonary support with a microaxial pump for the failing Fontan physiology.
Zhu, Jiaquan; Kato, Hideyuki; Fu, Yaqin Y; Zhao, Lisa; Foreman, Celeste; Davey, Lisa; Weisel, Richard D; Van Arsdell, Glen S; Honjo, Osami
2015-01-01
The number of patients with the failing Fontan physiology is increasing. We tested a novel in situ microaxial pump (Impella) to support the failing atrio-pulmonary Fontan circulation in an acute pig model. A Fontan model was established in eight juvenile pigs by connecting the right atrium to the main pulmonary artery after tricuspid valve destruction. The Impella pump was inserted retrograde from the distal main pulmonary artery into the right atrium. Hemodynamics, blood gas, and echocardiographic data were compared among baseline, pure Fontan physiology (10 minutes), and mechanically assisted Fontan physiology (up to 12 hours). The Impella system generated a blood flow of 75-85 ml/kg/minute in six animals, and 55-65 ml/kg/minute in two animals. The mechanically assisted Fontan attained a significantly higher mean blood pressure (39.6 ± 7 vs. 24.7 ± 3.3 mm Hg, p < 0.01), lower central venous pressure (5 ± 2.4 vs. 12.8 ± 1.7 mm Hg, p < 0.01), and higher mixed venous saturation (60.4 ± 10.8 vs. 23.4 ± 8.4 mm Hg, p < 0.01) compared with pure Fontan physiology. Cardiac output and stroke volume were similar during baseline and mechanically assisted Fontan (p = not significant). This acute pig study demonstrated the feasibility of mechanical circulatory support in the failing Fontan physiology. The in situ microaxial pump maintained cardiac output while increasing blood pressure and reducing venous pressure.
Heart failure is a condition in which the heart can't pump enough blood to meet the body's needs. Heart failure does not mean that your heart has stopped ... and shortness of breath Common causes of heart failure are coronary artery disease, high blood pressure and ...
Baskett, Roger J F; O'Connor, Gerald T; Hirsch, Gregory M; Ghali, William A; Sabadosa, Kathy; Morton, Jeremy R; Ross, Cathy S; Hernandez, Felix; Nugent, William C; Lahey, Stephen J; Sisto, Donato A; Dacey, Lawrence J; Klemperer, John D; Helm, Robert E; Maitland, Andrew
2003-12-01
Single-center studies suggest substantial variation in intraaortic balloon pump (IABP) utilization. Our purpose is to examine IABP utilization over time and across medical centers. This was a prospective cohort of 29,961 consecutive patients undergoing isolated coronary artery bypass graft surgery, between 1995 and 2000, at 10 centers (eight in northern New England and two in Canada). A total of 2,678 (8.9%) patients received an IABP. The rate of preoperative IABP insertion was 6.3%, and that of intra- or postoperative insertion was 2.6%. During the 6 years, IABP use increased from 7.0% to 10.3% (p(trend) <0.001). Preoperative IABP insertion increased from 5.4% to 7.8% (p(trend) < 0.001). There was no significant increase in intra-/postoperative IABP insertion 1.7% to 3.4% (p(trend) = 0.34). Adjustment for changes in patient and disease characteristics did not substantially alter these results. The rate of IABP use varied substantially by center, from 5.9% to 16.4% (p < 0.001). Adjustment for patient and disease characteristics resulted in variation from 4.8% to 12.8% across the 10 centers (p < 0.001). The adjusted rates of preoperative IABP insertion varied from 3.6% to 13.7% (p < 0.001), and the rates of intra-/postoperative IABP insertion ranged from 1.0% to 5.2% (p < 0.001). There was no significant correlation between the rates of preoperative and intra-/postoperative IABP use (r(s) = 0.085, p = 0.815). During the 6 years, there was a 47% increase in the rate of IABP utilization. Even after adjustment, there was almost threefold variation in IABP use across centers. This variation likely reflects lack of consensus on the appropriate use of the IABP in CABG patients.
Pierri, Michele Danilo; Crescenzi, Giuseppe; Zingaro, Carlo; D'Alfonso, Alessandro; Capestro, Filippo; Scocco, Vitangelo; Brugia, Marina; Torracca, Lucia
2016-07-01
This randomized controlled trial aimed to evaluate the effects of seven-day preoperative treatment with two different dosages of atorvastatin on the incidence of postoperative atrial fibrillation (POAF) and release of inflammatory markers such as high-sensitive C-reactive protein (hsCRP) and interleukin-6 in patients undergoing elective first-time on-pump coronary artery bypass grafting (CABG). The cohort study comprised 212 consecutive patients, already taking statins, who underwent elective first-time CABG with cardiopulmonary bypass without history of atrial fibrillation (AF). Patients were randomly divided into two groups: those who received atorvastatin 40 mg (TOR40 group, 111 patients) and those who received 80 mg (TOR80 group, 101 patients) once a day for 7 days before the planned operation. The primary endpoint was the incidence of AF. The secondary endpoints were the postoperative variations of inflammatory markers, hospital length of stay, and the incidence of major adverse cardiac and clinical events. A total of 26 patients (23.6 %) pretreated with atorvastatin 40 mg and 16 (15.8 %) patients pretreated with atorvastatin 80 mg had postoperative AF but the difference did not reach the statistical significance (p = 0.157). Median values of interleukin-6 and hsCRP at 12 and 24 h did not have differences between the two groups. No statistically significant differences in the other secondary endpoints were detected. According to our result, 7-day preoperative treatment with a high dose of atorvastatin is associated with a trend to a decrease in the incidence of POAF compared with treatment at a lower dose, although it does not impact on the level of inflammatory markers. European Clinical Trials Database (EudraCT: 2006-005757-30).
Deppe, Antje-Christin; Weber, Carolyn; Liakopoulos, Oliver J; Zeriouh, Mohamed; Slottosch, Ingo; Scherner, Maximilian; Kuhn, Elmar W; Choi, Yeong-Hoon; Wahlers, Thorsten
2017-03-01
Prophylactic intra-aortic balloon pump (IABP) support for high-risk patients before coronary artery bypass grafting (CABG) is controversial. This meta-analysis sought to determine the current role of preoperative IABP support. We performed a meta-analysis of randomized (RCT) and observational trials (OT) that fulfilled the following criteria: (1) Group comparison of patients with prophylactic IABP implantation before CABG with a control group; (2) reporting at least one desired clinical endpoint, including all-cause mortality, myocardial infarction, cerebrovascular accident (CVA), and renal failure. Pooled treatment effects (odds ratio [OR] or weighted mean difference, and 95% confidence intervals [95%CI]) were assessed using a fixed or random effects model. A total of 9,212 patients from 23 studies (7 RCT, 16 OT) were identified after a literature search of major databases using a predefined keyword list. Absolute risk reduction for mortality in RCTs was 4.4% (OR 0.43; 95%CI 0.25-0.73; p = 0.0025). Prophylactic IABP use before CABG surgery also decreased the risk for myocardial infarction (OR 0.58; 95%CI 0.43-0.78; p = 0.004), CVA (OR 0.67; 95%CI 0.47-0.97; p = 0.042), and renal failure (OR 0.62; 95%CI 0.47-0.83; p = 0.0014). Length of intensive care unit stay (p < 0.0001) and length of hospital stay (p < 0.0001) were significantly reduced in patients with preoperative IABP use. Current evidence from RCT and OT suggests beneficial effects for the IABP in high-risk patients before CABG surgery. © 2017 Wiley Periodicals, Inc.
Wan, You-Dong; Sun, Tong-Wen; Kan, Quan-Cheng; Guan, Fang-Xia; Liu, Zi-Qi; Zhang, Shu-Guang
2016-01-01
Background Intra-aortic balloon pumps (IABP) have generally been used for patients undergoing high-risk mechanical coronary revascularization. However, there is still insufficient evidence to determine whether they can improve outcomes in reperfusion therapy patients, mainly by percutaneous coronary intervention (PCI) with stenting or coronary artery bypass graft (CABG). This study was designed to determine the difference between high-risk mechanical coronary revascularization with and without IABPs on mortality, by performing a meta-analysis on randomized controlled trials of the current era. Methods Pubmed and Embase databases were searched from inception to May 2015. Unpublished data were obtained from the investigators. Randomized clinical trials of IABP and non-IABP in high-risk coronary revascularization procedures (PCI or CABG) were included. In the case of PCI procedures, stents should be used in more than 80% of patients. Numbers of events at the short-term and long-term follow-up were extracted. Results A total of 12 randomized trials enrolling 2155 patients were included. IABPs did not significantly decrease short-term mortality (relative risk (RR) 0.66; 95% CI, 0.42–1.01), or long-term mortality (RR 0.79; 95% CI, 0.47–1.35), with low heterogeneity across the studies. The findings remained stable in patients with acute myocardial infarction with or without cardiogenic shock. But in high-risk CABG patients, IABP was associated with reduced mortality (71 events in 846 patients; RR 0.40; 95%CI 0.25–0.67). Conclusion In patients undergoing high-risk coronary revascularization, IABP did not significantly decrease mortality. But high-risk CABG patients may be benefit from IABP. Rigorous criteria should be applied to the use of IABPs. PMID:26784578
Sá, Michel Pompeu B O; Ferraz, Paulo E; Escobar, Rodrigo R; Martins, Wendell N; Nunes, Eliobas O; Vasconcelos, Frederico P; Lima, Ricardo C
2012-11-01
The aim of this study was to assess the efficacy of a prophylactic intra-aortic balloon pump (IABP) in high-risk patients undergoing coronary artery bypass graft surgery. MEDLINE, EMBASE, CENTRAL/CCTR, SciELO, LILACS, Google Scholar, and reference lists of relevant articles were searched. We included only randomized controlled trials. Assessments for eligibility, relevance, and study validity and data extraction were performed in duplicate using prespecified criteria. Meta-analysis was carried out using fixed-effect and random-effect models. Seven publications fulfilled our eligibility criteria. There was no important statistical heterogeneity or publication bias among included studies. In total, 177 patients received prophylactic IABP and 168 did not. Overall relative risk (RR) for hospital mortality in patients treated with prophylactic IABP was 0.255 [95% confidence interval (CI), 0.122-0.533; P<0.001; same results for both effect models]. Pooled RR for postoperative low cardiac output syndrome was 0.206 (95% CI, 0.109-0.389; P<0.001) for the fixed-effect model and 0.219 (95% CI, 0.095-0.504; P<0.001) for the random-effect model. Patients treated with prophylactic IABP presented an overall difference in means for length of intensive care unit stay and hospital stay, which was lower than that in the control group (P<0.001 for both effect models). Only 7.4% (13/177) of patients who received prophylactic IABP developed complications at an insertion site, with no IABP-related death. This meta-analysis supports the use of prophylactic IABP in high-risk patients to reduce hospital mortality. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.
A microfluidic circulatory system integrated with capillary-assisted pressure sensors.
Chen, Yangfan; Chan, Ho Nam; Michael, Sean A; Shen, Yusheng; Chen, Yin; Tian, Qian; Huang, Lu; Wu, Hongkai
2017-02-14
The human circulatory system comprises a complex network of blood vessels interconnecting biologically relevant organs and a heart driving blood recirculation throughout this system. Recreating this system in vitro would act as a bridge between organ-on-a-chip and "body-on-a-chip" and advance the development of in vitro models. Here, we present a microfluidic circulatory system integrated with an on-chip pressure sensor to closely mimic human systemic circulation in vitro. A cardiac-like on-chip pumping system is incorporated in the device. It consists of four pumping units and passive check valves, which mimic the four heart chambers and heart valves, respectively. Each pumping unit is independently controlled with adjustable pressure and pump rate, enabling users to control the mimicked blood pressure and heartbeat rate within the device. A check valve is located downstream of each pumping unit to prevent backward leakage. Pulsatile and unidirectional flow can be generated to recirculate within the device by programming the four pumping units. We also report an on-chip capillary-assisted pressure sensor to monitor the pressure inside the device. One end of the capillary was placed in the measurement region, while the other end was sealed. Time-dependent pressure changes were measured by recording the movement of the liquid-gas interface in the capillary and calculating the pressure using the ideal gas law. The sensor covered the physiologically relevant blood pressure range found in humans (0-142.5 mmHg) and could respond to 0.2 s actuation time. With the aid of the sensor, the pressure inside the device could be adjusted to the desired range. As a proof of concept, human normal left ventricular and arterial pressure profiles were mimicked inside this device. Human umbilical vein endothelial cells (HUVECs) were cultured on chip and cells can respond to mechanical forces generated by arterial-like flow patterns.
NASA Technical Reports Server (NTRS)
Brooks, R. L. (Inventor)
1979-01-01
A multipoint fluid sample collection and distribution system is provided wherein the sample inputs are made through one or more of a number of sampling valves to a progressive cavity pump which is not susceptible to damage by large unfiltered particles. The pump output is through a filter unit that can provide a filtered multipoint sample. An unfiltered multipoint sample is also provided. An effluent sample can be taken and applied to a second progressive cavity pump for pumping to a filter unit that can provide one or more filtered effluent samples. The second pump can also provide an unfiltered effluent sample. Means are provided to periodically back flush each filter unit without shutting off the whole system.
Quantitative analysis of backflow of reversible pump-turbine in generating mode
NASA Astrophysics Data System (ADS)
Liu, K. H.; Zhang, Y. N.; Li, J. W.; Xian, H. Z.
2016-05-01
Significant vibration and pressure fluctuations are usually observed when pump- turbine is operated during the off-design conditions, especially turbine brake and runaway. The root cause of these instability phenomena is the abnormal unsteady flow (especially the backflow) inside the pump-turbine. In the present paper, numerical simulation method is adopted to investigate the characteristics of the flow inside the whole passage of pump-turbine with two guide vane openings (6° and 21° respectively) and three kinds of operating conditions (turbine, runaway and turbine braking respectively). A quantitative analysis of backflow is performed in both the axial and radial directions and the generation and development of backflow in the pump turbine are revealed with great details.
The optimal operation of cooling tower systems with variable-frequency control
NASA Astrophysics Data System (ADS)
Cao, Yong; Huang, Liqing; Cui, Zhiguo; Liu, Jing
2018-02-01
This study investigates the energy performance of chiller and cooling tower systems integrated with variable-frequency control for cooling tower fans and condenser water pumps. With regard to an example chiller system serving an office building, Chiller and cooling towers models were developed to assess how different variable-frequency control methods of cooling towers fans and condenser water pumps influence the trade-off between the chiller power, pump power and fan power under various operating conditions. The matching relationship between the cooling tower fans frequency and condenser water pumps frequency at optimal energy consumption of the system is introduced to achieve optimum system performance.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-18
... Industry and FDA Staff; Total Product Life Cycle: Infusion Pump--Premarket Notification [510(k... for Industry and FDA Staff; Total Product Life Cycle: Infusion Pump--Premarket Notification [510(k... Staff; Total Product Life Cycle: Infusion Pump--Premarket Notification [510(k)] Submissions--0910-NEW...
Firoozabadi, Mehdi Dehghani; Sheikhi, Mohammad Ali; Rahmani, Hossein; Ebadi, Ahmad; Heidari, Amanollah; Gholizadeh, Behnam; Sharifi, Khosrow
2017-10-01
Sulfur mustard (SM) is a toxic chemical agent that belongs to a class of vesicant compounds. In the 1980s it was used by the Iraqi army against Iranian forces. Sulfur mustard severely irritates the skin, eyes and lungs. The highest side effects seen in patients affected by this gas are pulmonary complications including different types of lung diseases such as bronchiolitis. It has also led to a certain type of chronic obstructive pulmonary disease called mustard lung. Similar extra-pulmonary, molecular and hormonal effects can be observed in these patients and patients with chronic obstructive pulmonary disease. Here cardiovascular complications may be one of the most dangerous visible effects. And atherosclerosis is probable following the direct effects or consequential long-term effects of SM. The development of atherosclerosis in these patients is associated with an increased risk of cardiovascular and coronary artery disease. Coronary artery bypass grafting surgery is the treatment of coronary artery disease. Doing this surgery by bypass pump has its own morbidity and due to local and systemic inflammation changes in patients with SM pulmonary disorders it may have more side effects. Therefore, detailed knowledge of inflammatory diseases as well as the serum level or even the local lung fluid of the inflammatory factors in these patients before surgery are needed so that it would be possible to reduce the rate of morbidity and mortality by normalizing the inflammatory conditions of the patients before cardiac surgery.
Muscle blood flow at onset of dynamic exercise in humans.
Rådegran, G; Saltin, B
1998-01-01
To evaluate the temporal relationship between blood flow, blood pressure, and muscle contractions, we continuously measured femoral arterial inflow with ultrasound Doppler at onset of passive exercise and voluntary, one-legged, dynamic knee-extensor exercise in humans. Blood velocity and inflow increased (P < 0.006) with the first relaxation of passive and voluntary exercise, whereas the arterial-venous pressure difference was unaltered [P = not significant (NS)]. During steady-state exercise, and with arterial pressure as a superimposed influence, blood velocity was affected by the muscle pump, peaking (P < 0.001) at approximately 2.5 +/- 0.3 m/s as the relaxation coincided with peak systolic arterial blood pressure; blood velocity decreased (P < 0.001) to 44.2 +/- 8.6 and 28.5 +/- 5.5% of peak velocity at the second dicrotic and diastolic blood pressure notches, respectively. Mechanical hindrance occurred (P < 0.001) during the contraction phase at blood pressures less than or equal to that at the second dicrotic notch. The increase in blood flow (Q) was characterized by a one-component (approximately 15% of peak power output), two-component (approximately 40-70% of peak power output), or three-component exponential model (> or = 75% of peak power output), where Q(t) = Qpassive + delta Q1.[1 - e-(t - TD1/tau 1)]+ delta Q2.[1 - e-(t - TD2/tau 2)]+ delta Q3.[1 - e-(t - TD3/tau 3)]; Qpassive, the blood flow during passive leg movement, equals 1.17 +/- 0.11 l/min; TD is the onset latency; tau is the time constant; delta Q is the magnitude of blood flow rise; and subscripts 1-3 refer to the first, second, and third components of the exponential model, respectively. The time to reach 50% of the difference between passive and voluntary asymptotic blood flow was approximately 2.2-8.9 s. The blood flow leveled off after approximately 10-150 s, related to the power outputs. It is concluded that the elevation in blood flow with the first duty cycle(s) is due to muscle mechanical factors, but vasodilators initiate a more potent amplification within the second to fourth contraction.
NASA Astrophysics Data System (ADS)
Maharjan, Madan
Groundwater response to stream stage fluctuations was studied using a year-long time series of stream stage and well heads in Glen Dale and New Martinsville, WV. Stream stage fluctuations exerted primary control over groundwater levels, especially during high flows. The location and operation of river pools created by dams alter groundwater flow paths and velocities. Aquifers are more prone to surface water infiltration in the upper reaches of pools than in lower reaches. Aquifer diffusivity is heterogeneous within and between the two sites. Temperature fluctuations were observed for 2.5 years in 14 wells in three alluvial aquifers. Temperature signals have 2 components corresponding to pump-on and pump-off periods. Both components vary seasonality at different magnitudes. While pump-off temperatures fluctuated up to 3.8o C seasonally, short-term temperature shifts induced by turning the pump on were 0.2 to 2.5o C. Pumping-induced temperature shifts were highest in magnitude in summer and winter. Groundwater temperature lagged behind that of surface water by approximately six months. Pumping induced and seasonal temperature shifts were spatially and temporally complex but indicate stream exfiltration is a major driver for a number of these wells. Numerical simulation of aquifer response to pumping show different conditions before and after well-field development. During pre-development, the stream was losing at high flow and gaining at low flow. During post-development, however, the stream was losing at high flow and spatially variable at low flow. While bank storage gained only during high stage, stream exfiltration occurred year-round. Pumping induced stream exfiltration by creating an extensive cone of depression beneath the stream in both upstream and downstream directions. Spatially and temporally variable groundwater-surface water interaction next to a regulated stream were studied using analytical and numerical models, based on field observations. Seasonality plays an important role in these interactions, but human activity may also alter its intensity.
Nishida, Masahiro; Nakayama, Kento; Sakota, Daisuke; Kosaka, Ryo; Maruyama, Osamu; Kawaguchi, Yasuo; Kuwana, Katsuyuki; Yamane, Takashi
2016-06-01
The effect of the flow path geometry of the impeller on the lift-off and tilt of the rotational axis of the impeller against the hydrodynamic force was investigated in a centrifugal blood pump with an impeller supported by a single-contact pivot bearing. Four types of impeller were compared: the FR model with the flow path having both front and rear cutouts on the tip, the F model with the flow path having only a front cutout, the R model with only a rear cutout, and the N model with a straight flow path. First, the axial thrust and the movement about the pivot point, which was loaded on the surface of the impeller, were calculated using computational fluid dynamics (CFD) analysis. Next, the lift-off point and the tilt of the rotational axis of the impeller were measured experimentally. The CFD analysis showed that the axial thrust increased gently in the FR and R models as the flow rate increased, whereas it increased drastically in the F and N models. This difference in axial thrust was likely from the higher pressure caused by the smaller circumferential velocity in the gap between the top surface of the impeller and the casing in the FR and R models than in the F and N models, which was caused by the rear cutout. These results corresponded with the experimental results showing that the impellers lifted off in the F and N models as the flow rate increased, whereas it did not in the FR and R models. Conversely, the movement about the pivot point increased in the direction opposite the side with the pump outlet as the flow rate increased. However, the tilt of the rotational axis of the impeller, which oriented away from the pump outlet, was less than 0.8° in any model under any conditions, and was considered to negligibly affect the rotational attitude of the impeller. These results confirm that a rear cutout prevents lift-off of the impeller caused by a decrease in the axial thrust. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Kimenai, D M; Bastianen, G W; Daane, C R; Megens-Bastiaanse, C M; van der Meer, N J M; Scohy, T V; Gerritse, B M
2013-11-01
The choice of the prime solution for cardiopulmonary bypass can play an important role in limiting the effect on blood coagulation, but it is still unclear what the effect of colloids on blood coagulation is. The aim of this study was to investigate the effect of synthetic colloids on blood loss and blood coagulation in patients after on-pump coronary artery bypass graft (CABG) procedures. Sixty elective, on-pump CABG patients were randomly assigned to receive the prime solutions lactated Ringer's solution combined with hydroxyethyl starch 130/0.4 (HES, 6% Volulyte, Fresenius Kabi Nederland BV, Zeist, the Netherlands) (HES group) or gelatin (Gelofusin(®), B Braun Melsung AG, Melsungen, Germany) (Gelo group). Blood loss was assessed using post-operative chest tube output; secondary endpoints were number of blood component transfusions, routine coagulation test values and rotation thromboelastometry values (Rotem(®) delta, Pentapharm GmbH, Munich, Germany). Total post-operative chest tube output was 500 ± 420 ml in the HES group versus 465 ± 390 ml in the Gelo group (p = 0.48). No significant differences were observed in any of the routine coagulation tests values, thromboelastometry parameters or number of blood component transfusions between the groups. In this randomized, controlled trial of adults after on-pump CABG procedures, there was no significant difference in blood loss or blood coagulation between the HES group and the Gelo group.
Spill-Detector-and-Shutoff Device
NASA Technical Reports Server (NTRS)
Jarvis, M. R.; Fulton, D. S.
1985-01-01
Overflow in liquid chromatography systems rapidly detected and stopped. Spill-detector-and-shutoff device incorporated into liquid-chromatography system. When liquid from output nozzle spills on liquid sensor, device automatically shuts off pump and releases solenoid to pinch off flow in tube. Device uses common type of alarm circuit reset manually before normal operation resumes.
Pulsed and cw laser oscillations in LiF:F-2 color center crystal under laser diode pumping.
Basiev, Tasoltan T; Vassiliev, Sergey V; Konjushkin, Vasily A; Gapontsev, Valentin P
2006-07-15
Continuous-wave laser oscillations in LiF:F-2 crystal optically pumped by a laser diode at 970 nm were demonstrated for what is believed to be the first time. The slope efficiency of 14% and conversion efficiency of 5.5% were achieved for 80 micros pump pulse duration and 5 Hz pulse repetition rate. An efficiency twice as low was measured at a 6.25 kHz pulse repetition rate (50% off-duty factor) and in cw mode of laser operation.
Endovascular Management of the Popliteal Artery: Comparison of Atherectomy and Angioplasty
Semaan, Elie; Hamburg, Naomi; Nasr, Wael; Shaw, Palma; Eberhardt, Robert; Woodson, Jonathan; Doros, Gheorghe; Rybin, Denis; Farber, Alik
2013-01-01
Purpose Symptomatic atherosclerotic disease of the popliteal artery presents challenges for endovascular therapy. We evaluated the technical success, complications and midterm outcomes of atherectomy and angioplasty involving the popliteal segment. Methods We conducted a retrospective review of outcomes of popliteal artery intervention using atherectomy or angioplasty performed between 2003 and 2008. Results A total of 56 patients (36% women, age 72.8±12.2 years, 77% critical limb ischemia) underwent popliteal atherectomy (n=18) or angioplasty (n=38). These patients had similar clinical characteristics, TASC/TASC II classification, mean lesion length, and run-off scores. We observed a trend toward higher rates of technical success defined as <30% residual stenosis after atherectomy compared to angioplasty (94% vs. 71%, p=0.08). While angioplasty was associated with a higher frequency of arterial dissection (23% vs. 0%, p=0.003), atherectomy was associated with a higher rate of thromboembolic events (22% vs 0%, p=0.01). Adjunctive stenting was used more frequently following angioplasty compared to atherectomy (45% vs. 6%, p=0.005). Thrombolysis was used to treat embolization in 4 patients in the atherectomy group. The improvement in the ankle-brachial index was similar between the two treatment groups. Primary patency of the popliteal artery at 3, 6, and 12 months was 94%, 88%, and 75% in the atherectomy group and 89%, 82%, and 73% in the angioplasty group (p=NS). There were no significant differences in limb salvage and freedom from reintervention at 1 year between the atherectomy and angioplasty groups. Conclusions Our experience with popliteal artery endovascular therapy indicates a distinct pattern of procedural complications with atherectomy compared to angioplasty but similar midterm patency, limb salvage and freedom from intervention. PMID:19942598
Al Jaaly, Emad; Chaudhry, Umar A R; Harling, Leanne; Athanasiou, Thanos
2015-04-01
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether beating-heart on-pump coronary artery bypass grafting (BH-ONCAB) offered superior mortality and morbidity outcomes when compared with conventional on-pump coronary artery bypass grafting (C-ONCAB). Morbidity outcomes consisted of renal failure, stroke (transient or permanent), myocardial infarction, angina, congestive cardiac failure, reintervention and arrhythmias. Best evidence papers investigating BH-ONCAB versus C-ONCAB were considered. Where data were duplicated, the more credible evidence-based and recently published study was included. Two hundred and thirty-one papers were found using the reported search, of which 11 represented the best evidence to answer the clinical question. Two were prospective randomized controlled trials and the remaining 10 observational studies, of which one was propensity-matched. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Five of these studies demonstrated significantly improved mortality following BH-ONCAB; however, one study exhibited better survival after C-ONCAB. Notably, this study incorporated BH-ONCAB patients with significantly more haemodynamic instability, thus possibly explaining the worse mortality outcomes. In terms of morbidity, a slightly more mixed picture is drawn. Five studies report morbidity in favour of BH-ONCAB, whereas three studies include individual outcomes favouring C-ONCAB. The remaining studies showed equivalent mortality and morbidity data. In summary, the results presented here suggest that BH-ONCAB may improve survival following coronary artery bypass surgery. A key observation is that the greatest benefits of BH-ONCAB appear to be in studies including patients with considerably higher risk characteristics at the time of surgery (haemodialysis, end-stage coronary artery disease, emergency surgery, low ejection fraction). There are limitations of the current evidence presented. Only two studies were randomized controlled trials. There was variability in sample size, selection criteria and preoperative risk profiles between the studies. The studies span many years, and the outcomes may have been affected by evolving technologies and differing patient profiles between these periods. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Ning, Nathan S P; Watkins, Susanne C; Gawne, Ben; Nielsen, Daryl L
2012-09-30
Water sharing to meet both agricultural and environmental demands is a critical issue affecting the health of many floodplain river systems around the world. This study explored the potential for using wetlands as temporary off-river storages to conjunctively maintain ecological values and support agricultural demands by assessing the effects of artificial drawdown on wetland aquatic plant communities. An initial experiment was undertaken in outdoor mesocosms in which four different treatments were compared over a 131 day duration: (1) natural drawdown where the water was left to drawdown naturally via evaporation; (2) partial drawdown where approximately half of the volume of water was pumped out after 42 days; (3) stepped drawdown where approximately half of the volume of water pumped out after 42 days, and then the remaining volume of water was pumped out after 117 days; and (4) total drawdown where all of the of water was pumped out after 117 days. A complementary field study was subsequently undertaken where two wetlands were left to drawdown naturally and two were partially drawn down artificially (i.e. had approximately half of their volume removed by pumping). Results from both of these studies indicated that neither aquatic plant abundance nor taxon richness were adversely affected by partial drawdown. Rather, both studies showed that aquatic plant communities subjected to a partial drawdown treatment became more species rich and diverse than communities subjected to a natural drawdown treatment. This suggests that it may be possible to use wetlands as intermediary storages for the dual purposes of maintaining ecological values and supporting agricultural demands. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yan, J. P.; Seidel, U.; Koutnik, J.
2012-11-01
The hydrodynamics of a reduced-scaled model of a radial pump-turbine is investigated under off-design operating conditions, involving runaway and "S-shape" turbine brake curve at low positive discharge. It is a low specific speed pump-turbine machine of Francis type with 9 impeller blades and 20 stay vanes as well as 20 guide vanes. The computational domain includes the entire water passage from the spiral casing inlet to the draft tube outlet. Completely structured hexahedral meshes generated by the commercial software ANSYS-ICEM are employed. The unsteady incompressible simulations are performed using the commercial code ANSYS-CFX13. For turbulence modeling the standard k-ε model is applied. The numerical results at different operating points are compared to the experimental results. The predicted pressure amplitude is in good agreement with the experimental data and the amplitude of normal force on impeller is in reasonable range. The detailed analysis reveals the onset of the flow instabilities when the machine is brought from a regular operating condition to runaway and turbine break mode. Furthermore, the rotating stall phenomena are well captured at runaway condition as well as low discharge operating condition with one stall cell rotating inside and around the impeller with about 70% of its frequency. Moreover, the rotating stall is found to be the effect of rotating flow separations developed in several consecutive impeller channels which lead to their blockage. The reliable simulation of S-curve characteristics in pump-turbines is a basic requirement for design and optimization at off-design operating conditions.
Engineering microbial biofuel tolerance and export using efflux pumps
Dunlop, Mary J; Dossani, Zain Y; Szmidt, Heather L; Chu, Hou Cheng; Lee, Taek Soon; Keasling, Jay D; Hadi, Masood Z; Mukhopadhyay, Aindrila
2011-01-01
Many compounds being considered as candidates for advanced biofuels are toxic to microorganisms. This introduces an undesirable trade-off when engineering metabolic pathways for biofuel production because the engineered microbes must balance production against survival. Cellular export systems, such as efflux pumps, provide a direct mechanism for reducing biofuel toxicity. To identify novel biofuel pumps, we used bioinformatics to generate a list of all efflux pumps from sequenced bacterial genomes and prioritized a subset of targets for cloning. The resulting library of 43 pumps was heterologously expressed in Escherichia coli, where we tested it against seven representative biofuels. By using a competitive growth assay, we efficiently distinguished pumps that improved survival. For two of the fuels (n-butanol and isopentanol), none of the pumps improved tolerance. For all other fuels, we identified pumps that restored growth in the presence of biofuel. We then tested a beneficial pump directly in a production strain and demonstrated that it improved biofuel yields. Our findings introduce new tools for engineering production strains and utilize the increasingly large database of sequenced genomes. PMID:21556065
Seeburger, Joerg; Rinaldi, Mauro; Nielsen, Sten Lyager; Salizzoni, Stefano; Lange, Ruediger; Schoenburg, Markus; Alfieri, Ottavio; Borger, Michael Andrew; Mohr, Friedrich Wilhelm; Aidietis, Audrius
2014-03-11
The goal of this study was to evaluate the safety and performance of the NeoChord DS1000 system (NeoChord, Inc., Minneapolis, Minnesota). There is an increasing interest in transcatheter mitral valve (MV) treatment. The NeoChord DS 1000 system enables off-pump beating heart transapical MV repair with implantation of artificial neo-chordae. Patients with severe mitral regurgitation (MR) due to isolated posterior prolapse were included in this TACT (Transapical Artificial Chordae Tendinae) trial. All patients were scheduled for off-pump transapical implantation of neo-chordae. Thirty patients at 7 centers were enrolled. Major adverse events included 1 death due to post-cardiotomy syndrome and concomitant sepsis and 1 minor stroke with the patient fully recovered at the 30-day follow-up visit. Additional patients experienced procedural major adverse events related to a reoperation or conversion to standard of care. Acute procedural success (placement of at least 1 neo-chord and reduction of MR from 3+ or 4+ to ≤2+) was achieved in 26 patients (86.7%). In 4 patients neo-chordae were not placed for technical and/or patient-specific reasons. These patients underwent intraoperative (3 patients) or post-operative (1 patient) standard MV repair. At 30 days, 17 patients maintained an MR grade ≤2+. Four patients who developed recurrent MR were successfully treated with open MV repair during 30-day follow-up. Results improved with experience: durable reduction in MR to ≤2+ at 30 days was achieved in 5 (33.3%) of the first 15 patients and 12 (85.7%) of the last 14 patients. Off-pump transapical implantation of artificial chordae to correct MR is technically safe and feasible; however, it yields further potential for improvement of efficacy and durability. (Safety and Performance Study of the NeoChord Device [TACT]; NCT01777815). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
ACCURACY OF NONINVASIVE ANESTHETIC MONITORING IN THE ANESTHETIZED GIRAFFE (GIRAFFA CAMELOPARDALIS).
Bertelsen, Mads F; Grøndahl, Carsten; Stegmann, George F; Sauer, Cathrine; Secher, Niels H; Hasenkam, J Michael; Damkjær, Mads; Aalkjær, Christian; Wang, Tobias
2017-09-01
This study evaluated the accuracy of pulse oximetry, capnography, and oscillometric blood pressure during general anesthesia in giraffes (Giraffa camelopardalis). Thirty-two giraffes anesthetized for physiologic experiments were instrumented with a pulse oximeter transmittance probe positioned on the tongue and a capnograph sampling line placed at the oral end of the endotracheal tube. A human size 10 blood pressure cuff was placed around the base of the tail, and an indwelling arterial catheter in the auricular artery continuously measured blood pressure. Giraffes were intermittently ventilated using a Hudson demand valve throughout the procedures. Arterial blood for blood gas analysis was collected at multiple time points. Relationships between oxygen saturation as determined by pulse oximetry and arterial oxygen saturation, between arterial carbon dioxide partial pressure and end-tidal carbon dioxide, and between oscillometric pressure and invasive arterial blood pressure were assessed, and the accuracy of pulse oximetry, capnography, and oscillometric blood pressure monitoring evaluated using Bland-Altman analysis. All three noninvasive methods provided relatively poor estimates of the reference values. Receiver operating characteristic curve fitting was used to determine cut-off values for hypoxia, hypocapnia, hypercapnia, and hypotension for dichotomous decision-making. Applying these cut-off values, there was reasonable sensitivity for detection of hypocapnia, hypercapnia, and hypotension, but not for hypoxemia. Noninvasive anesthetic monitoring should be interpreted with caution in giraffes and, ideally, invasive monitoring should be employed.
Drinkhill, M J; Doe, C P; Myers, D S; Self, D A; Hainsworth, R
1997-11-01
The existence of abdominal arterial baroreceptors has long been controversial. Previously difficulties have been encountered in localizing a stimulus to abdominal arteries without affecting reflexogenic areas elsewhere. In these experiments, using anaesthetized dogs, the abdomen was vascularly isolated at the level of the diaphragm, perfused through the aorta, and drained from the inferior vena cava to a reservoir. Changes in abdominal arterial pressure were effected by changing the perfusion pump speed. During this procedure the flow back to the animal from the venous outflow reservoir was held constant. Increases and decreases in abdominal arterial pressure resulted, respectively, in decreases and increases in perfusion pressure to a vascularly isolated hind-limb and in some dogs also a forelimb. Responses were significantly larger when carotid sinus pressure was high (120-180 mmHg) than when it was low (60 mmHg). Responses were still obtained after cutting vagus, phrenic and splanchnic nerves, but were abolished by spinal cord lesion at T12. These experiments provide evidence for the existence of abdominal arterial baroreceptors. The afferent pathway for the reflex vasodilatation appears to run in the spinal cord.
Franzoso, Francesca D; Wohlmuth, Christoph; Greutmann, Matthias; Kellenberger, Christian J; Oxenius, Angela; Voser, Eva M; Valsangiacomo Buechel, Emanuela R
2016-09-01
The atria serve as reservoir, conduit, and active pump for ventricular filling. The performance of the atrial baffles after atrial switch repair for transposition of the great arteries may be abnormal and impact the function of the systemic right ventricle. We sought to assess atrial function in patients after atrial repair in comparison to patients after arterial switch repair (ASO) and to controls. Using magnetic resonance imaging, atrial volumes and functional parameters were measured in 17 patients after atrial switch repair, 9 patients after ASO and 10 healthy subjects. After the atrial switch operation, the maximum volume of the pulmonary venous atrium was significantly enlarged, but not of the systemic venous atrium. In both patients groups, independently from the surgical technique used, the minimum atrial volumes were elevated, which resulted in a decreased total empting fraction compared with controls (P < .01). The passive empting volume was diminished for right atrium, but elevated for left atrium after atrial switch and normal for left atrium after ASO; however, the passive empting fraction was diminished for both right atrium and left atrium after both operations (P < .01). The active empting volume was the most affected parameter in both atria and both groups and active empting fractions were highly significantly reduced compared with controls. Atrial function is abnormal in all patients, after atrial switch and ASO repair. The cyclic volume changes, that is, atrial filling and empting, are reduced when compared with normal subjects. Thus, the atria have lost part of their capacity to convert continuous venous flow into a pulsatile ventricular filling. The function of the pulmonary venous atrium, acting as preload for the systemic right ventricle, after atrial switch is altered the most. © 2015 Wiley Periodicals, Inc.
Hernandez-Suarez, Dagmar F.; Scott, Stuart A.; Tomey, Matthew I.; Melin, Kyle; Lopez-Candales, Angel; Buckley, Charlotte E.; Duconge, Jorge
2017-01-01
Background: Clopidogrel is by far the most prescribed platelet adenosine diphosphate (ADP) antagonist in Puerto Rico despite the advent of newer agents (prasugrel and ticagrelor). Given the paucity of data on clopidogrel responsiveness in Hispanics, we sought to determine the association between clinical characteristics and platelet reactivity in Puerto Rican patients on clopidogrel therapy. Study population: A total of 100 Puerto Rican patients on clopidogrel therapy were enrolled and allocated into two groups: Group I, without high on-treatment platelet reactivity (HTPR); and Group II, with HTPR. Platelet function was measured ex vivo using the VerifyNow® P2Y12 assay. Results: The cohort was comprised of Hispanic patients with coronary artery disease (57%), peripheral artery disease (32%), carotid artery stenosis (7%), cerebral artery aneurysm (2%), and stroke (2%). Mean platelet reactivity was 200 ± 61 P2Y12 reaction units (PRUs) (range: 8–324), and 35% of patients had HTPR (PRUs ⩾ 230). Multivariable logistic regression analysis determined that diabetes mellitus (DM) [odds ratio (OR) = 3.27; 95% confidence interval (CI): 1.20–8.96], use of proton-pump inhibitors (PPIs) (OR = 3.60; 95% CI: 1.09–11.82), and calcium channel blockers (CCBs) (OR = 3.10; 95% CI: 1.09–8.83) were independent predictors of HTPR (p < 0.05) after adjusting for other clinical variables. Conclusions: In a sample of 100 Puerto Rican Hispanic patients on clopidogrel, 35% had HTPR. Furthermore, DM, PPIs and CCBs predicted HTPR. Clinical outcome data are needed to identify appropriate PRU thresholds for risk prediction in the Puerto Rican population. PMID:28675986
Vakili, Manzar; Shirani, Shapour; Paknejad, Omalbanin; Yousefshahi, Fardin
2015-01-01
Acute Respiratory Distress Syndrome (ARDS) is a potential complication of cardiac surgery, given that patients undergoing CABG frequently have hypoxemia and pulmonary dysfunction during initial hours after surgery. Thus, ARDS criteria in these patients are more likely to be positive while these criteria may not match the patient`s clinical picture. We aimed to investigate frequency of rapid onset hypoxemia in Pressure of Arterial Oxygen to Fractional Inspired Oxygen Concentration (PaO2/FiO2) less than 200 and diffuse pulmonary infiltrates as two diagnostic criteria forwards and compared these criteria with the clinical picture of the patients after Coronary Artery Bypass Graft (CABG) in this study. The study was prospective case series which carried out in about six months. All patients admitted to intensive care unit of Tehran Heart Center, who had undergone CABG on cardiopulmonary pump (CPB) recruited in the study. After considering inclusion criteria, age, sex, duration of intubation, arterial blood gas and chest radiography, on 24 hours and 48 hours after admission to the ICU were recorded. Then, patients with rapid onset of hypoxemia (PaO2/FiO2≤200mmHg) and diffuse pulmonary infiltrates and without sign or symptoms of obvious heart failure (probable positive ARDS cases) criteria were recorded and comparison between these probable positive cases with clinician`s clinical diagnosis (blinded to the study) was performed. In this study, a total of 300 patients after on-pump coronary artery bypass surgery were included. Postoperatively, 2 (0.66 %) in the 24 hours and 4 (1.33%) patients in 48 hours after surgery were positive for the two ARDS criteria according to the checklists, but; nobody had saved persistently ARDS criteria persistently during 48 hours after surgery. At the same time, clinician did not report any case of ARDS among 300 patients. In this study patients with ARDS criteria had no significant differences in age (P.value=0.937) and sex (P.value=0.533). Duration of intubation in patients with ARDS (14.26 ± 4.25 hours) in the first 48 hours was higher but not statistically different from the group without ARDS (11.60 ± 5.45 hours) (P.value=0.236). ARDS diagnosis based on rapid onset of hypoxemia (PaO2/FiO2≤200 mmHg) and diffuse pulmonary infiltrates and without signs or symptoms of obvious heart failure criteria in patients undergoing CABG could lead to overdiagnosis or misdiagnosis in less than 24 hours follow up. We recommend following patients for more than 24 hours and revise the current ARDS criteria for CABG patients.
Pulmonary MRA: differentiation of pulmonary embolism from truncation artefact.
Bannas, Peter; Schiebler, Mark L; Motosugi, Utaroh; François, Christopher J; Reeder, Scott B; Nagle, Scott K
2014-08-01
Truncation artefact (Gibbs ringing) causes central signal drop within vessels in pulmonary magnetic resonance angiography (MRA) that can be mistaken for emboli, reducing diagnostic accuracy for pulmonary embolism (PE). We propose a quantitative approach to differentiate truncation artefact from PE. Twenty-eight patients who underwent pulmonary computed tomography angiography (CTA) for suspected PE were recruited for pulmonary MRA. Signal intensity drops within pulmonary arteries that persisted on both arterial-phase and delayed-phase MRA were identified. The percent signal loss between the vessel lumen and central drop was measured. CTA served as the reference standard for presence of pulmonary emboli. A total of 65 signal intensity drops were identified on MRA. Of these, 48 (74%) were artefacts and 17 (26%) were PE, as confirmed by CTA. Truncation artefacts had a significantly lower median signal drop than PE on both arterial-phase (26% [range 12-58%] vs. 85% [range 53-91%]) and delayed-phase MRA (26% [range 11-55%] vs. 77% [range 47-89%]), p < 0.0001 for both. Receiver operating characteristic (ROC) analyses revealed a threshold value of 51% (arterial phase) and 47% signal drop (delayed phase) to differentiate between truncation artefact and PE with 100% sensitivity and greater than 90% specificity. Quantitative signal drop is an objective tool to help differentiate truncation artefact and pulmonary embolism in pulmonary MRA. • Inexperienced readers may mistake truncation artefacts for emboli on pulmonary MRA • Pulmonary emboli have non-uniform signal drop • 51% (arterial phase) and 47% (delayed phase) cut-off differentiates truncation artefact from PE • Quantitative signal drop measurement enables more accurate pulmonary embolism diagnosis with MRA.
NORTH PORTAL-HOT WATER CIRCULATION PUMP CALCULATION-SHOP BUILDING #5006
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Blackstone
1996-01-25
The purpose of this design analysis and calculation is to size a circulating pump for the service hot water system in the Shop Building 5006, in accordance with the Uniform Plumbing Code (Section 4.4.1) and U.S. Department of Energy Order 6430.1A-1540 (Section 4.4.2). The method used for the calculation is based on Reference 5.2. This consists of determining the total heat transfer from the service hot water system piping to the surrounding environment. The heat transfer is then used to define the total pumping capacity based on a given temperature change in the circulating hot water as it flows throughmore » the closed loop piping system. The total pumping capacity is used to select a pump model from manufacturer's literature. This established the head generation for that capacity and particular pump model. The total length of all hot water supply and return piping including fittings is then estimated from the plumbing drawings which defines the pipe friction losses that must fit within the available pump head. Several iterations may be required before a pump can be selected that satisfies the head-capacity requirements.« less
Development and application of a double-piston configured, total-liquid ventilatory support device.
Meinhardt, J P; Quintel, M; Hirschl, R B
2000-05-01
Perfluorocarbon liquid ventilation has been shown to enhance pulmonary mechanics and gas exchange in the setting of respiratory failure. To optimize the total liquid ventilation process, we developed a volume-limited, time-cycled liquid ventilatory support, consisting of an electrically actuated, microprocessor-controlled, double-cylinder, piston pump with two separate limbs for active inspiration and expiration. Prospective, controlled, animal laboratory study, involving sequential application of conventional gas ventilation, partial ventilation (PLV), and total liquid ventilation (TLV). Research facility at a university medical center. A total of 12 normal adult New Zealand rabbits weighing 3.25+/-0.1 kg. Anesthestized rabbits were supported with gas ventilation for 30 mins (respiratory rate, 20 cycles/min; peak inspiratory pressure, 15 cm H2O; end-expiratory pressure, 5 cm H2O), then PLV was established with perflubron (12 mL/kg). After 15 mins, TLV was instituted (tidal volume, 18 mL/kg; respiratory rate, 7 cycles/min; inspiratory/expiratory ratio, 1:2 cycles/min). After 4 hrs of TLV, PLV was re-established. Of 12 animals, nine survived the 4-hr TLV period. During TLV, mean values +/- SEM were as follows: PaO2, 363+/-30 torr; PaCO2, 39+/-1.5 torr; pH, 7.39+/-0.01; static peak inspiratory pressure, 13.2+/-0.2 cm H2O; static endexpiratory pressure, 5.5+/-0.1 cm H2O. No significant changes were observed. When compared with gas ventilation and PLV, significant increases occurred in mean arterial pressure (62.4+/-3.5 torr vs. 74.0+/-1.2 torr) and central venous pressure (5.6+/-0.7 cm H2O vs. 7.8+/-0.2 cm H2O) (p < .05). Total liquid ventilation can be performed successfully utilizing piston pumps with active expiration. Considering the enhanced flow profiles, this device configuration provides advantages over others.
Benard, Nicolas; Coisne, Damien; Donal, Erwan; Perrault, Robert
2003-07-01
The stimulation of endothelial cells by arterial wall shear stress (WSS) plays a central role in restenosis. The fluid-structure interaction between stent wire and blood flow alters the WSS, particularly between stent struts. We have designed an in vitro model of struts of an intra-vascular prosthesis to study blood flow through a 'stented' section. The experimental artery consisted of a transparent square section test vein, which reproduced the strut design (100x magnifying power). A programmable pump was used to maintain a steady blood flow. Particle image velocimetry method was used to measure the flow between and over the stent branches, and to quantify WSS. Several prosthesis patterns that were representative of the total stent strut geometry were studied in a greater detail. We obtained WSS values of between -1.5 and 1.5Pa in a weak SS area which provided a source of endothelial stimulation propitious to restenosis. We also compared two similar patterns located in two different flow areas (one at the entry of the stent and one further downstream). We only detected a slight difference between the weakest SS levels at these two sites. As the endothelial proliferation is greatly influenced by the SS, knowledge of the SS modification induced by the stent implantation could be of importance for intra-vascular prostheses design optimisation and thus can help to reduce the restenosis incidence rate.
Anomalous origin of right coronary artery from left coronary sinus.
Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I
2008-08-01
Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kern, F.H.; Ungerleider, R.M.; Quill, T.J.
1991-04-01
We examined the relationship of changes in partial pressure of carbon dioxide on cerebral blood flow responsiveness in 20 pediatric patients undergoing hypothermic cardiopulmonary bypass. Cerebral blood flow was measured during steady-state hypothermic cardiopulmonary bypass with the use of xenon 133 clearance methodology at two different arterial carbon dioxide tensions. During these measurements there was no significant change in mean arterial pressure, nasopharyngeal temperature, pump flow rate, or hematocrit value. Cerebral blood flow was found to be significantly greater at higher arterial carbon dioxide tensions (p less than 0.01), so that for every millimeter of mercury rise in arterial carbonmore » dioxide tension there was a 1.2 ml.100 gm-1.min-1 increase in cerebral blood flow. Two factors, deep hypothermia (18 degrees to 22 degrees C) and reduced age (less than 1 year), diminished the effect carbon dioxide had on cerebral blood flow responsiveness but did not eliminate it. We conclude that cerebral blood flow remains responsive to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in infants and children; that is, increasing arterial carbon dioxide tension will independently increase cerebral blood flow.« less
Langhoff, R; Stumpe, S; Treitl, M; Schulte, K L
2013-10-01
The management of progressive peripheral artery disease experienced a vast change in paradigms over the last decades for the benefit of minimal invasive therapy as a first-line strategy. With the constant development of new devices, materials and dedicated access strategies, more complex lesions can be managed but the limitations to successfully treat chronic total occlusions are still the challenge to re-enter the true lumen. The aim of this retrospective study was to investigate, if a "wire only" strategy leads to an acceptable success rate in a mixed cohort of CTO lesions and to what extend re-entry devices are used. We retrospectively analyzed patients treated at the Vascular Center Berlin between 2011 and 2013 with chronic total occlusion out of a prospective conducted database (Endovascular MILestones - EMIL) for demographics, risk factors, co-morbidities, technical success rates, lesion characteristics and use of guidewires as well as re-entry systems. A total of 128 patients with 146 lesions, which represent a subgroup of all the cases performed in our center, following a predefined treatment algorithm for chronic total occlusions (CTOs), have been analyzed. We achieved a technical success in 133 (91.1%) of all cases following a "wire only" strategy. Out of 13 (8.9%) CTOs with technical failure in 7 (53.9%) CTOs a re-entry device (Off-Road®) with a 100% technical success has been used. In 91.1% of chronic total occlusion lesions the use of 2 wires only (88.7%) led to a successful recanalization. A "wire only" strategy followed by the use of a re-entry device as a bail out strategy, led to a total of 140 (96%) lesions to be successfully recanalized. In more than 90% of all cases with chronic total occlusion of peripheral lower extremity arteries, endovascular intervention has been successful following a "wire only" strategy. When deciding to use a re-entry device, in case of a failure of a proper wire re-entry at the reconstitution point, a technical success rate of 100% was achieved. Therefore following a strict wire algorithm and considering the use of a re-entry system as a bail out strategy will lead to a successful minimal invasive management of chronic total occlusion in nearly 100% of the cases with TASC II A - D lesions.
[Prevention of cerebrovascular complications in coronary artery bypass grafting].
Mialiuk, P A; Marchenko, A V; Arutiunian, V B; Chragian, V A; Alekseevich, G Iu; Vronskiĭ, A S
The authors carried out a comparative analysis of the incidence rate of cerebrovascular complications following coronary artery bypass grafting performed using either a differentiated approach to surgical policy depending on the findings of epiaortic ultrasonographic scanning or the standard conventional approach. A total of 3,454 operations of coronary artery bypass grafting were performed. All patients were divided into two groups. Patients of the Study Group (n=765) were subjected to obligatory intraoperative epiaortic scanning, with the variant of further surgical intervention depending on the obtained findings of the examination. The Control Group patients (n=2,689) underwent standard coronary artery bypass grafting in the conditions of artificial circulation (AC). In the Study Group patients, depending on the degree and localization of the atherosclerotic lesion of the aorta, determined by the findings of epiaortic scanning, one of the following techniques of coronary artery bypass grafting (CABG) was chosen: cases with no lesion were managed by CABG with AC (585 patients); a local solitary lesion was managed by altering the site of cannulation and application of the clamp (92 patients) or by the operation according to the 'single clamp' technique (43 patients); cases of manifested atherosclerosis of the ascending aorta were treated by the 'on-pump beating-heart' technique in the conditions of AC without placing clamps (27 patients); cases of massive involvement of the ascending aorta and aortic arch were managed by CABG performed according to the 'no-touch aorta' technique (18 patients). The total mortality rate amounted to 1.1%. Thirty-three (0.96%) patients in the postoperative period were found to have ischaemic stroke. The mortality rate in the Control Group amounted to 1.4% and that in the Study Group equalled 0.3%, with the number of cases of ischaemic strokes amounting to 33 (1.4%) and 0, respectively. Perioperative infarction was diagnosed in 16 (0.6%) cases in the Control Group and in 5 (0.7%) patients in the group treated using the differentiated approach. A conclusion was drawn that the differentiated approach to choosing the technique of CABG based on the findings obtained by means of epiaortic scanning was associated with a statistically significant decrease in both the number of ischaemic strokes and the mortality rate after CABG operations.
Blood transfusion and risk of atrial fibrillation after coronary artery bypass graft surgery
Liu, Shengqun; Li, Zhanwen; Liu, Zhe; Hu, Zhenhua; Zheng, Gaifang
2018-01-01
Abstract The aim of this study was to systematically evaluate the effect of blood transfusion (BT) on postoperative atrial fibrillation (AF) in adult patients who had undergone coronary artery bypass grafting (CABG) surgery. PubMed, Embase, and Cochrane Library databases from inception to January 2017 were searched. Cohort studies were searched that evaluated the association between BT and the risk of postoperative AF in adult patients who had undergone CABG surgery. Study quality was assessed by using the Newcastle–Ottawa scale (NOS). A meta-analysis was performed with the random-effect model. Eight cohort studies involving 7401 AF cases and 31,069 participants were identified and included in our data analysis. The pooled odds ratio of postoperative AF in patients with BT was 1.45 (95% confidence interval, 1.26–1.67), with significant heterogeneity (P < .0001, I2 = 79%). Excluding one study that had an off-pump CABG did not significantly impact this result (odds ratio, 1.36; 95% confidence interval, 1.23–1.50; n = 7). To examine the stability of the primary results, we performed subgroup analyses. The association between BT and the risk of postoperative AF was similar, as determined in the stratified analyses conducted according to study design, type of surgery, and country. The findings of the present meta-analysis demonstrated a statistically significant increase in postoperative AF risk among adult patients with BT. Further prospective large-scale studies are needed to establish causality and to elucidate the underlying mechanisms. PMID:29517692
Lubricating Oil Burn-Off in Coast Guard Power Plants
1975-02-01
of the in-line fuel filters and wear of the fuel pumps . The overwhelming majority of tests performed by others in L• lube oil burn-off programs...February 1975 IAJBRICATING OIL BURN-OFF IN 6. perfarming Organization Code COAST GUARD POWER PLANTS ___________A. Performing Organization Report No. 7...Authorls) J.R. Hobbs and R. A. WalterDOTC-JC76 9. Performing Organization Name and Address 10. Work Unit No. (TRAIS) U.S. Department of Transportation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raebiger, K.; Faculty of Advanced Technology, University of Glamorgan, Pontypridd, Wales; Maksoud, T.M.A.
In the investigation of the pumping behaviour of multiphase screw pumps, handling gas-liquid mixtures with very high gas volume fractions, theoretical and experimental analyses were performed. A new theoretical screw pump model was developed, which calculates the time-dependent conditions inside the several chambers of a screw pump as well as the exchange of mass and energy between these chambers. By means of the performed experimental analysis, the screw pump model was verified, especially at very high gas volume fractions from 90% to 99%. The experiments, which were conducted with the reference fluids water and air, can be divided mainly intomore » the determination of the steady state pumping behaviour on the one hand and into the analysis of selected transient operating conditions on the other hand, whereas the visualisation of the leakage flows through the circumferential gaps was rounded off the experimental analysis. (author)« less
Dual-channel current valve in a three terminal zigzag graphene nanoribbon junction
NASA Astrophysics Data System (ADS)
Zhang, L.
2017-02-01
We theoretically propose a dual-channel current valve based on a three terminal zigzag graphene nanoribbon (ZGNR) junction driven by three asymmetric time-dependent pumping potentials. By means of the Keldysh Green’s function method, we show that two asymmetric charge currents can be pumped in the different left-right terminals of the device at a zero bias, which mainly stems from the single photon-assisted pumping approximation and the valley valve effect in a ZGNR p-n junction. The ON and OFF states of pumped charge currents are crucially dependent on the even-odd chain widths of the three electrodes, the pumping frequency, the lattice potential and the Fermi level. Two-tunneling spin valves are also considered to spatially separate and detect 100% polarized spin currents owing to the combined spin pump effect and the valley selective transport in a three terminal ZGNR ferromagnetic junction. Our investigations might be helpful to control the spatial and spin degrees of freedom of electrons in graphene pumping devices.
Ring-Down Spectroscopy for Characterizing a CW Raman Laser
NASA Technical Reports Server (NTRS)
Matsko, Andrey; Savchenkov, Anatoliy; Maleki, Lute
2007-01-01
.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.
NASA Technical Reports Server (NTRS)
Schaub, J. D.; Koenig, S. C.; Schroeder, M. J.; Ewert, D. L.; Drew, G. A.; Swope, R. D.; Convertino, V. A. (Principal Investigator)
1999-01-01
An in vitro pulsatile pump flow system that is capable of producing physiologic pressures and flows in a mock circulatory system tuned to reproduce the first nine harmonics of the input impedance of a rhesus monkey was developed and tested. The system was created as a research tool for evaluating cardiovascular function and for the design, testing, and evaluation of electrical-mechanical cardiovascular models and chronically implanted sensors. The system possesses a computerized user interface for controlling a linear displacement pulsatile pump in a controlled flow loop format to emulate in vivo cardiovascular characteristics. Evaluation of the pump system consisted of comparing its aortic pressure and flow profiles with in vivo rhesus hemodynamic waveforms in the time and frequency domains. Comparison of aortic pressure and flow data between the pump system and in vivo data showed good agreement in the time and frequency domains, however, the pump system produced a larger pulse pressure. The pump system can be used for comparing cardiovascular parameters with predicted cardiovascular model values and for evaluating such items as vascular grafts, heart valves, biomaterials, and sensors. This article describes the development and evaluation of this feedback controlled cardiovascular dynamics simulation modeling system.
Two Wavelength Ti:sapphire Laser for Ozone DIAL Measurements from Aircraft
NASA Technical Reports Server (NTRS)
Situ, Wen; DeYoung, Russel J.
1998-01-01
Laser remote sensing of ozone from aircraft has proven to be a valuable technique for understanding the distribution and dynamics of ozone in the atmosphere. Presently the differential absorption lidar (DIAL) technique, using dual ND:YAG lasers that are doubled to pump dye lasers which in turn are doubled into the UV for the "on" and "off' line lasers, is used on either the NASA DC-8 or P-3 aircraft. Typically, the laser output for each line is 40-mJ and this is split into two beams, one looking up and the other downward, each beam having about 20-mJ. The residual ND:YAG (1.06 micron) and dye laser energies are also transmitted to obtain information on the atmospheric aerosols. While this system has operated well, there are several system characteristics that make the system less than ideal for aircraft operations. The system, which uses separate "on" and "off" line lasers, is quite large and massive requiring valuable aircraft volume and weight. The dye slowly degrades with time requiring replacement. The laser complexity requires a number of technical people to maintain the system performance. There is also the future interest in deploying an ozone DIAL system in an Unpiloted Atmospheric Vehicle (UAV) which would require a total payload mass of less than 150 kg and power requirement of less than 1500 W. A laser technology has emerged that could potentially provide significant enhancements over the present ozone DIAL system. The flashlamp pumped Ti:sapphire laser system is an emerging technology that could reduce the mass and volume over the present system and also provide a system with fewer conversion steps, reducing system complexity. This paper will discuss preliminary results from a flashlamp-pumped Ti:sapphire laser constructed as a radiation source for a UV DIAL system to measure ozone.
Totally Endoscopic Coronary Artery Bypass for Anomalous Origin of Right Coronary Artery.
Kuo, Chia-Cheng; Hsing, Chung-Hsi; Cheng, Bor-Chih
2017-01-01
Anomalous origin of the right coronary artery (ARCA) from the left Valsalva sinus is a rare but known cause of sudden cardiac death. Surgical revascularization techniques include coronary artery bypass grafting, unroofing, and reimplantation. We report 4 patients who underwent robot-assisted totally endoscopic coronary artery bypass (TECAB) for ARCA as an alternative surgical option. In 3 patients, a single aortocoronary saphenous vein bypass was performed, and in 1 patient the right internal mammary artery was used. All grafts are patent as shown by computed tomographic angiography or cardiac catheterization. We claim that totally endoscopic coronary artery bypass is feasible and safe for anomalous origin of the right coronary artery. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Missed Total Occlusion Due to the Occipital Artery Arising from the Internal Carotid Artery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ustunsoz, Bahri, E-mail: bustunsoz2000@yahoo.com; Gumus, Burcak; Koksal, Ali
2007-02-15
A 56-year-old man was referred for digital subtraction angiography (DSA) with an ultrasound diagnosis of right proximal internal carotid artery (ICA) stenosis for possible carotid artery stenting. DSA revealed total occlusion of the ICA and an occipital artery arising from the stump and simulating continuation of the ICA. An ascending pharyngeal artery also arose from the same occipital artery. This case is of interest because this is a rare variation besides being a cause of misdiagnosis at carotid ultrasound.
Hydrogen-Fuel Engine Component Tests Near Completion
NASA Technical Reports Server (NTRS)
2003-01-01
Gaseous hydrogen is burned off at the E1 Test Stand the night of Oct. 7 during a cold-flow test of the fuel turbopump of the Integrated Powerhead Demonstrator (IPD) at NASA Stennis Space Center (SSC). The gaseous hydrogen spins the pump's turbine during the test, which was conducted to verify the pump's performance. Engineers plan one more test before sending the pump to The Boeing Co. for inspection. It will then be returned to SSC for engine system assembly. The IPD is the first reusable hydrogen-fueled advanced engine in development since the Space Shuttle Main Engine.
Hydrogen-Fuel Engine Component Tests Near Completion
2003-11-05
Gaseous hydrogen is burned off at the E1 Test Stand the night of Oct. 7 during a cold-flow test of the fuel turbopump of the Integrated Powerhead Demonstrator (IPD) at NASA Stennis Space Center (SSC). The gaseous hydrogen spins the pump's turbine during the test, which was conducted to verify the pump's performance. Engineers plan one more test before sending the pump to The Boeing Co. for inspection. It will then be returned to SSC for engine system assembly. The IPD is the first reusable hydrogen-fueled advanced engine in development since the Space Shuttle Main Engine.
Thévenin, Fabrice S; Drapé, Jean-Luc; Biau, David; Campagna, Raphaël; Richarme, Delphine; Guerini, Henri; Chevrot, Alain; Larousserie, Frédérique; Babinet, Antoine; Anract, Philippe; Feydy, Antoine
2010-06-01
To evaluate the accuracy of computed tomography angiography (CTA) in predicting arterial encasement by limb tumours, by comparing CTA with surgical findings (gold standard). Preoperative CTA images of 55 arteries in 48 patients were assessed for arterial status: cross-sectional CTA images were scored as showing a fat plane between artery and tumour (score 0), slight contact between artery and tumour (score 1), partial arterial encasement (score 2) or total arterial encasement (score 3). Reformatted CTA images were assessed for arterial displacement, rigid wall, stenosis or occlusion. At surgery, arteries were classified as free or surgically encased; 45 arteries were free and 10 were surgically encased. Multivariate logistic regression identified the axial CTA score as a relevant predictor for arterial encasement and subsequent vascular intervention during surgery. All sites where CTA showed a fat plane between the tumour and the artery were classified as free at surgery (n = 28/28). The sensitivity of total arterial encasement on CTA (score 3) was 90%, specificity 93%, accuracy 93% and positive likelihood ratio 13.5. CTA evidence of total arterial encasement is a highly specific indication of arterial encasement. The presence of fat between the tumour and the artery on CTA rules out arterial involvement at surgery.
Synchronization modulation of Na/K pumps on Xenopus oocytes
NASA Astrophysics Data System (ADS)
Liang, Pengfei; Mast, Jason; Chen, Wei
We developed a new technique named synchronization modulation to electrically synchronize and modulate the Na/K pump molecules by a specially designed oscillating electric field. This technique is based on the theory of energy-trap in quantum physics as well as the concept of electronic synchrotron accelerator. As a result, the Na-transports are all entrapped into the positive half-cycle of the applied electric field and consequently, all of the K-transports are entrapped into the negative half cycle of the field. To demonstrate the process of the pump synchronization and modulation, we use Xenopus oocytes as a platform and introduce two-electrode whole-cell voltage clamp in measurement of pump current. Practically, we first synchronize the pump molecules running at the same pace (rate and phase) by a specially designed oscillation electric field. Then, we carefully maintain the pump synchronization status and gradually change the field frequency (decrease and increase) to modulate the pump molecules to newer pumping rate. The result shows a separation of the inward K current from the outward Na current, and about 10 time increase of the total (inward plus outward) pump current from the net outward current from the random paced pump molecules. Also, the ratio of the modulated total pump current with synchronized total pump current is consistent with the ratio of their field frequencies.
NASA Astrophysics Data System (ADS)
Kawo, Nafyad Serre; Zhou, Yangxiao; Magalso, Ronnell; Salvacion, Lasaro
2018-05-01
A coupled simulation-optimization approach to optimize an artificial-recharge-pumping system for the water supply in the Maghaway Valley, Cebu, Philippines, is presented. The objective is to maximize the total pumping rate through a system of artificial recharge and pumping while meeting constraints such as groundwater-level drawdown and bounds on pumping rates at each well. The simulation models were coupled with groundwater management optimization to maximize production rates. Under steady-state natural conditions, the significant inflow to the aquifer comes from river leakage, whereas the natural discharge is mainly the subsurface outflow to the downstream area. Results from the steady artificial-recharge-pumping simulation model show that artificial recharge is about 20,587 m3/day and accounts for 77% of total inflow. Under transient artificial-recharge-pumping conditions, artificial recharge varies between 14,000 and 20,000 m3/day depending on the wet and dry seasons, respectively. The steady-state optimisation results show that the total optimal abstraction rate is 37,545 m3/day and artificial recharge is increased to 29,313 m3/day. The transient optimization results show that the average total optimal pumping rate is 36,969 m3/day for the current weir height. The transient optimization results for an increase in weir height by 1 and 2 m show that the average total optimal pumping rates are increased to 38,768 and 40,463 m3/day, respectively. It is concluded that the increase in the height of the weir can significantly increase the artificial recharge rate and production rate in Maghaway Valley.
Laser Diode Pumped Solid State Lasers
1987-01-01
Report N66001-83-C-0071, 17 April 1986, prepared for NOSC. 4.6 W.T. Welford, R. Winston , "The Option of Nonimaging Concentrators ," Academic Press, 1978...by non-imac optics such as reflective or refractive flux concentrators . Simple considerations regarding the optimum pumping configuration, high marks...reduced if the arrays can stand-off from the Nd:YAG laser. As mentioned before, compound parabolic concentrators or refractive optics cat employed to
Koyuncu, Hasan; Ceylan, Rahime
2018-04-01
Dynamic Contrast-Enhanced Computed Tomography (DCE-CT) is applied to observe adrenal tumours in detail by utilising from the contrast matter, which generally brings the tumour into the forefront. However, DCE-CT images are generally influenced by noises that occur as the result of the trade-off between radiation doses vs. noise. Herein, this situation constitutes a challenge in the achievement of accurate tumour segmentation. In CT images, most of the noises are similar to Gaussian Noise. In this study, arterial phase CT images containing adrenal tumours are utilised, and elimination of Gaussian Noise is realised by fourteen different techniques reported in literature for the achievement of the best denoising process. In this study, the Block Matching and 3D Filtering (BM3D) algorithm typically achieve reliable Peak Signal-to-Noise Ratios (PSNR) and resolves challenges of similar techniques when addressing different levels of noise. Furthermore, BM3D obtains the best mean PSNR values among the first five techniques. BM3D outperforms to other techniques by obtaining better Total Statistical Success (TSS), CPU time and computation cost. Consequently, it prepares clearer arterial phase CT images for the next step (segmentation of adrenal tumours). Copyright © 2017 Elsevier Ltd. All rights reserved.
Werner, Gerald S; Ahmed, Waqar H
2017-09-01
Covered stents are indicated for coronary perforations, but they may seal off major side branches in that process. We report the successful sealing of an ostial left main perforation, induced by a guide catheter in the course of a retrograde approach to treat a chronic total occlusion (CTO) of the right coronary artery (RCA) in a 76year old woman with prior CABG. The implanted Papyrus covered stent, however, overlapped the left main bifurcation and occluded the non-grafted circumflex artery (CX) resulting in acute ischemia. Through a double lumen catheter advanced over the wire located in the left anterior descending coronary artery (LAD) territory, a stiff recanalization wire could be advanced from the side-port to penetrate the stent membrane towards the CX. This was successfully achieved, and after subsequent dilatation, a drug-eluting stent was implanted in Culotte-fashion from the CX to the left main with subsequent kissing-balloon dilatation. The clinical symptoms subsided immediately, and the RCA was finally recanalized in antegrade parallel wire technique. No periprocedural infarct was observed during 48h of follow-up before discharge. At clinical follow-up of 6months the patient is symptom-free. Copyright © 2017 Elsevier Inc. All rights reserved.
Guan, Zheng; Lv, Yi; Liu, Jingjie; Liu, Lin; Yuan, Hui; Shen, Xin
2016-12-01
To determine whether smoking cessation can reduce the incidence of postoperative hypoxemia (POH) after on-pump coronary artery bypass grafting (CABG) surgery. Prospective, single-center, observational study. Single-center university teaching hospital. The study comprised 300 patients undergoing on-pump CABG surgery who met the inclusion criteria. Patients were divided into the following 3 groups according to smoking status: sustained quitters (n = 132)-smoking cessation for more than 1 month and less than 1 year; quitters (n = 95)-smoking cessation for more than 1 week and less than 1 month; and smokers (n = 73)-smoking at least 1 cigarette per day for at least 1 year. None. The primary outcome was the incidence of POH after on-pump CABG surgery. Secondary outcomes included length of postoperative mechanical ventilation and intensive care unit stay between the POH group and non-POH group. There were significant decreases of POH incidence in the sustained quitters and quitters compared with the smokers both after intensive care unit (ICU) admission and 24 hours after surgery (18.2%, 18.9%, v 32.9%; p = 0.036 and 9.8%, 10.5%, v 26%; p = 0.003, respectively), and there was no significant difference in POH incidence between the sustained quitters and quitters. The length of postoperative mechanical ventilation was longer in smokers than in sustained quitters and quitters (15.9±6.1 h v 11.9±5.3 h and 13.0±5.8 h, respectively; p<0.05), but there were no significant differences in the length of ICU stay among the 3 groups (54.2±7.5 h v 55.1±7.5 h and 53.7±6.6 h, respectively; p = 0.333). Smoking cessation can reduce POH after on-pump CABG surgery, and it also can shorten the length of postoperative mechanical ventilation. Copyright © 2016 Elsevier Inc. All rights reserved.
Addai, Theodore; Kola, Monahar; Raqeem, Muhammad Wajih; Barsamyan, Sergey; Mirrakhimov, Aibek E.
2016-01-01
An 82-year-old female with history of hyperlipidemia and hypertension presented to the clinic with chief complaint of nonradiating chest tightness accompanied by exertional dyspnea. Cardiac catheterization showed the absence of left coronary system; the entire coronary system originated from the right aortic sinus as a common trunk which then gave off the right coronary artery and the left main coronary artery. Cardiac catheterization demonstrated also another rare coronary anomaly: dual left anterior descending artery. Patient underwent percutaneous coronary intervention and subsequent multidetector computed tomography angiography confirmed the above angiography findings. Patient was subsequently discharged home on double antiplatelet therapy with aspirin and clopidogrel and has been asymptomatic since then. PMID:27293909
Measurement of viscous flow velocity and flow visualization using two magnetic resonance imagers
NASA Astrophysics Data System (ADS)
Boiko, A. V.; Akulov, A. E.; Chupakhin, A. P.; Cherevko, A. A.; Denisenko, N. S.; Savelov, A. A.; Stankevich, Yu. A.; Khe, A. K.; Yanchenko, A. A.; Tulupov, A. A.
2017-03-01
The accuracies of measuring the velocity field using clinical and research magnetic resonance imagers are compared. The flow velocity of a fluid simulating blood in a carotid artery model connected to a programmable pump was measured. Using phase-contrast magnetic resonance tomography, the velocity distributions in the carotid artery model were obtained and compared with the analytical solution for viscous liquid flow in a cylindrical tube (Poiseuille flow). It is found that the accuracy of the velocity measurement does not depend on the field induction and spatial resolution of the imagers.
Huber, Christoph H; Tozzi, Piergiorgio; Hurni, Michel; von Segesser, Ludwig K
2004-06-01
The new magnetically suspended axial pump is free of seals, bearings, mechanical friction and wear. In the absence of a drive shaft or flow meter, pump flow assessment is made with an algorithm based on currents required for impeller rotation and stabilization. The aim of this study is to validate pump performance, algorithm-based flow and effective flow. A series of bovine experiments was realized after equipment with pressure transducers, continuous-cardiac-output-catheter, intracardiac ultrasound (AcuNav) over 6 h. Pump implantation was through a median sternotomy (LV-->VAD-->calibrated transonic-flow-probe-->aorta). A transonic-HT311-flow-probe was fixed onto the outflow cannula for flow comparison. Animals were electively sacrificed and at necropsy systematic pump inspection and renal embolus score was realized. Observation period was 340+/-62.4 min. The axial pump generated a mean arterial pressure of 58.8+/-14.3 mmHg (max 117 mmHg) running at a speed of 6591.3+/-1395.4 rev./min (min 5000/max 8500 rev./min) and generating 2.5+/-1.0 l/min (min 1.4/max 6.0 l/min) of flow. Correlation between the results of the pump flow algorithm and measured pump flow was linear (y=1.0339x, R2=0.9357). VAD explants were free of macroscopic thrombi. Renal embolus score was 0+/-0. The magnetically suspended axial flow pump provides excellent left ventricular support. The pump flow algorithm used is accurate and reliable. Therefore, there is no need for direct flow measurement.
Liquid rocket engine axial-flow turbopumps
NASA Technical Reports Server (NTRS)
Scheer, D. D.; Huppert, M. C.; Viteri, F.; Farquhar, J.; Keller, R. B., Jr. (Editor)
1978-01-01
The axial pump is considered in terms of the total turbopump assembly. Stage hydrodynamic design, pump rotor assembly, pump materials for liquid hydrogen applications, and safety factors as utilized in state of the art pumps are among the topics discussed. Axial pump applications are included.
Watanabe, Hiroki; Morimoto, Takeshi; Shiomi, Hiroki; Kawaji, Tetsuma; Furukawa, Yutaka; Nakagawa, Yoshihisa; Ando, Kenji; Kadota, Kazushige; Kimura, Takeshi
2017-09-30
We aimed to investigate the effect of chronic total occlusion (CTO) in non-infarct-related artery (IRA) on short- and long-term mortality in ST-segment elevation myocardial infarction (STEMI) patients complicated by cardiogenic shock (CS). Previous studies show contradictory results about the clinical effect of CTO in non-IRA on short-term mortality in STEMI patients with CS. From the CREDO-Kyoto AMI registry enrolling 5429 patients, the current study population consisted of 313 STEMI patients with multivessel disease complicated by CS who underwent primary PCI for the nonleft main coronary artery culprit lesion within 24 hr after onset. They were divided according to the presence of CTO (CTO group: N = 100 and non-CTO group: N = 213). Hemodynamic compromise was more profound in the CTO group as suggested by the more frequent use of intra-aortic balloon pumping and/or extracorporeal membrane oxygenation. Infarct size estimated by the peak creatine phosphokinase level was larger in the CTO group than in the non-CTO group. The cumulative 30-day and 5-year incidences of all-cause death were significantly higher in the CTO group than in the non-CTO group (34.0% vs 18.0%, P = 0.001, and 64.5% vs 46.0%, P = 0.0001). After adjusting for confounders, the excess risk of the CTO group relative to the non-CTO group for all-cause death remained significant both at 30 days and at 5 years (hazard ratio [HR]: 2.05, 95% confidence interval [CI]: 1.27-3.29, P = 0.003, and HR: 1.90, 95% CI: 1.34-2.69, P = 0.0004). In STEMI patients complicated by CS, CTO in non-IRA was associated with increased 30-day and 5-year mortality. © 2017 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Ho, Son H.; Rahman, Muhammad M.
2008-01-01
This paper presents a study on fluid flow and heat transfer of liquid hydrogen in a zero boil-off cryogenic storage tank in a microgravity environment. The storage tank is equipped with an active cooling system consisting of a heat pipe and a pump-nozzle unit. The pump collects cryogen at its inlet and discharges it through its nozzle onto the evaporator section of the heat pipe in order to prevent the cryogen from boiling off due to the heat leaking through the tank wall from the surroundings. A three-dimensional (3-D) finite element model is employed in a set of numerical simulations to solve for velocity and temperature fields of liquid hydrogen in steady state. Complex structures of 3-D velocity and temperature distributions determined from the model are presented. Simulations with an axisymmetric model were also performed for comparison. Parametric study results from both models predict that as the speed of the cryogenic fluid discharged from the nozzle increases, the mean or bulk cryogenic fluid speed increases linearly and the maximum temperature within the cryogenic fluid decreases.
Brightness enhancement limits in pulsed cladding-pumped fiber Raman amplifiers
NASA Astrophysics Data System (ADS)
Ji, Junhua; Codemard, Christophe A.; Nilsson, Johan
2010-02-01
We analyze theoretically limitations on brightness enhancement of a multimode pump beam into a diffraction-limited Stokes beam in efficient cladding-pumped fiber Raman amplifiers. Firstly, the power-scaling of the 1st Stokes (hence the brightness enhancement) is limited by the generation of the 2nd order Stokes. Thus using a spectral waveguide filter such as a W-type fiber core, it is possible to improve this limit to nearly five times that of a normal fiber without spectral filter. Secondly, we analyze limits set by glass damage, propagation loss, and pump-signal pulse walk-off in the multimode fiber. We show that a well-designed fiber with a propagation loss of 3.5 dB/km allows for a pump-to-signal brightness improvement of over 1000 times for pulses longer than 40 ns and up to 3500 times in the cw regime.
Micromorphology of Skeletonized and Pedicled Internal Thoracic and Radial Arteries.
Mamchur, Sergey; Bokhan, Nikita; Vecherskii, Yuri; Malyshenko, Egor
2015-01-01
The objective of the study was to estimate the internal thoracic arteries (ITA) and radial arteries (RA) micromorphologic features by light microscopy after harvesting them using the skeletonization and pedicled methods in patients undergoing coronary artery bypass grafting. The micromorphologic characteristics of ITA and RA were studied by luminous microscopy in 61 patients undergoing coronary artery bypass grafting. A total of 122 ITA and RA segments harvested during surgery, fixed in formalin, and stained with hematoxiline and eosin were evaluated. The mean intima-media thickness of ITA was 9.2 and 134.7 µm and that of RA was 9.1 and 334.2 µm, respectively. In the distal segment of ITA the media-intima relation was 1.5 times bigger than in the proximal segment. None of ITA specimens contained atherosclerotic plaques or lipid inclusions. Atherosclerotic plaques were found in 3 (5%) RA specimens. Other degenerative changes were detected in 30%-74.2% of the specimens: splitting of internal elastic lamina, reduced tortuosity of the internal elastic lamina, and thickening and detachment of the intima; their incidence was associated with the skeletonization of the vessels. In conclusion, the incidence of ITA and RA degenerative changes varies from 30%-74.2% and its increase is associated with the skeletonization of the vessels, which is statistically significant. The media of the RA is 2.5 times thicker than that of the ITA (P < 0.01). This fact shows that RA has higher spasmogenic potential than that of ITA. The distal segment of the ITA has 1.5 times bigger media-intima relation than the proximal segment. Therefore, in case of enough graft length, it is recommended to avoid the distal segment and cut it off. Copyright © 2015 Elsevier Inc. All rights reserved.
Yazici, Raziye; Guney, İbrahim; Altintepe, Lutfullah; Yazici, Mehmet
2017-01-01
The relationship between serum uric acid and arterial stiffness or blood pressure is not clear. The serum uric acid level and its association with cardiovascular risk is not well known in patients with reduced renal mass. We aimed to investigate the relation between serum uric acid levels and arterial stiffness and also blood pressure in patients with congenital renal agenesis and/or hypoplasia. In this single center, cross-sectional study, a total of 55 patients (39 (% 70.9) with unilateral small kidney and 16 (%29.1) with renal agenesis) were included. The median age was 35 (21-50) years. The study population was divided into tertiles of serum uric acid (according to 2.40-3.96, 3.97-5.10, and 5.11-9.80 mg/dl cut-off values of serum uric acid levels). Official and 24-h ambulatory non-invasive blood pressures of all patients were measured. The arterial stiffness was assessed by pulse wave velocity (PWV). PWV values were increased from first to third tertile (5.5 ± 0.6, 5.7 ± 0.8, 6.1 ± 0.7, respectively), but this gradual increase between tertiles did not reach significance. Linear regression analyses showed a positive correlation between serum uric acid levels and PWV (β = 0.40, p = 0.010), but no correlation was found between uric acid and daytime systolic blood pressure (β = 0.24, p = 0.345). In congenital renal agenesis/hypoplasia, the serum uric acid level was positively correlated with arterial stiffness, but there was no correlation with blood pressure.
Biological Half-Life of Cardiolite[R
ERIC Educational Resources Information Center
Jesse, Kenneth
2008-01-01
I recently had a cardiac stress test. It was my fourth. Its purpose was to determine whether my heart is pumping an adequate quantity of blood during exercise. Additionally, is there a partial arterial blockage or damaged heart muscle? The test involves the patient receiving an injection of Cardiolite[R], a substance containing a molecule to which…
Variation in hospital rates of intraaortic balloon pump use in coronary artery bypass operations.
Ghali, W A; Ash, A S; Hall, R E; Moskowitz, M A
1999-02-01
Little is known about regional patterns of intraaortic balloon pump (IABP) use in coronary artery bypass graft (CABG) operations. Our objectives were (1) to identify clinical variables associated with IABP use, and (2) to examine risk-adjusted rates of IABP use for 12 Massachusetts hospitals performing CABG operations. We used hospital discharge data to identify 6944 CABG surgical cases. Logistic regression was used to identify clinical variables associated with IABP use, and the resulting multivariate model was then used to risk adjust hospital rates of IABP use. The IABP was used in 13.4% of the CABG surgical cases. The clinical variables independently associated with IABP use were cardiogenic shock, same admission angioplasty, prior CABG operation, cardiac arrest, congestive heart failure, recent myocardial infarction, and urgent admission status. Risk-adjusted rates of IABP use varied widely across hospitals from 7.8% to 20.8% (p < 0.0001). Hospital rates of IABP use vary considerably in Massachusetts. This practice variation may be related to the persistent uncertainty regarding the precise clinical indications for the IABP in this patient population.
Estimating pumping time and ground-water withdrawals using energy- consumption data
Hurr, R.T.; Litke, D.W.
1989-01-01
Evaluation of the hydrology of an aquifer requires knowledge about the volume of groundwater in storage and also about the volume of groundwater withdrawals. Totalizer flow meters may be installed at pumping plants to measure withdrawals; however, it generally is impractical to equip all pumping plants in an area with meters. A viable alternative is the use of rate-time methods. Rate-time methods may be used at individual pumping plants to decrease the data collection necessary for determining withdrawals. At sites where pumping-time measurement devices are not installed, pumping time may be determined on the basis of energy consumption and power demand. At pumping plants where energy consumption is metered, data acquired by reading of meters is used to estimate pumping time. Care needs to be taken to read these meters correctly. At pumping plants powered by electricity, the calculations need to be modified if transformers are present. At pumping plants powered by natural gas, the effects of the pressure-correction factor need to be included in the calculations. At pumping plants powered by gasoline, diesel oil, or liquid petroleum gas, the geometry of storage tanks needs to be analyzed as part of the calculations. The relation between power demand and pumping rate at a pumping plant can be described through the use of the power-consumption coefficient. Where equipment and hydrologic conditions are stable, this coefficient can be applied to total energy consumption at a site to estimate total groundwater withdrawals. Random sampling of power consumption coefficients can be used to estimate area-wide groundwater withdrawal. (USGS)
[Clinical study of recurrent stomach cancer].
Taguchi, T
1983-11-01
There are various patterns of recurrence of gastric cancer after radical resection, such as hepatic metastasis, carcinomatous peritonitis, residual stomach recurrence, local lymph node metastasis and establishment of distant metastasis. In cases of residual stomach recurrence, resection is sometimes feasible. Kruckenberg's tumor resulting from metastasis to the ovary can frequently be removed. With such resectable metastasis, surgical procedure is actively employed, with subsequent chemotherapy. Chemotherapy in such a case consists of combined chemotherapy by arterial infusion for induction of remission and administration of oral preparation and/or suppositories for maintenance. In the treatment of recurrent gastric cancer by arterial infusion, we made it a rule to administer drugs through a catheter inserted subselectively into the aorta. In the treatment by arterial infusion, the daily administration of 5-FU serves as the basic regimen. Dissolve 250 mg 5-FU in about 20 cc physiologic saline or 5% dextrose solution, and infuse the solution over 2 hrs with the use of a continuous arterial infusion pump. Administer of 5-FU daily, and fortify this treatment by one-shot injection of MMC 10mg/body each time, MMC is usually given 3-4 times, with intervals between its administrations adjusted according to WBC and platelet counts. ADM is given at dosage of 40 mg/body each time. We found it advisable to continue the administrations of 5-FU until its total dose reached about 20 g, while giving sufficient doses of ADM or MMC for induction of remission. The results obtained from 108 cases of the recurrent gastric cancer were shown as follows. The median survival period was 5 months. The twenty-one cases out of 108 cases in recurrent gastric cancer survived more than one year, because they received the intensive chemotherapy such as arterial infusion chemotherapy and oral or rectal administration of FT. The most patients with liver metastasis were treated with selective arterial infusion chemotherapy consisting of 5-FU plus MMC or ACNU. And the efficacy of arterial infusion chemotherapy was remarkable. Our efforts must be made to continue any treatment as long as possible and change drugs as necessary. Also we must keep general condition of the patients as good as possible using support therapy such as IVH, prevention of infection, immunotherapy, drainage so on.
Ca2+ removal mechanisms in rat cerebral resistance size arteries.
Kamishima, T; McCarron, J G
1998-01-01
Tissue blood flow and blood pressure are each regulated by the contractile behavior of resistance artery smooth muscle. Vascular diseases such as hypertension have also been attributed to changes in vascular smooth muscle function as a consequence of altered Ca2+ removal. In the present study of Ca2+ removal mechanisms, in dissociated single cells from resistance arteries using fura-2 microfluorimetry and voltage clamp, Ca2+ uptake by the sarcoplasmic reticulum and extrusion by the Ca2+ pump in the cell membrane were demonstrably important in regulating Ca2+. In contrast, the Na+-Ca2+ exchanger played no detectable role in clearing Ca2+. Thus a voltage pulse to 0 mV, from a holding potential of -70 mV, triggered a Ca2+ influx and increased intracellular Ca2+ concentration ([Ca2+]i). On repolarization, [Ca2+]i returned to the resting level. The decline in [Ca2+]i consisted of three phases. Ca2+ removal was fast immediately after repolarization (first phase), then plateaued (second phase), and finally accelerated just before [Ca2+]i returned to resting levels (third phase). Thapsigargin or ryanodine, which each inhibit Ca2+ uptake into stores, did not affect the first but significantly inhibited the third phase. On the other hand, Na+ replacement with choline+ did not affect either the phasic features of Ca2+ removal or the absolute rate of its decline. Ca2+ removal was voltage-independent; holding the membrane potential at 120 mV, rather than at -70 mV, after the voltage pulse to 0 mV, did not attenuate Ca2+ removal rate. These results suggest that Ca2+ pumps in the sarcoplasmic reticulum and the plasma membrane, but not the Na+-Ca2+ exchanger, are important in Ca2+ removal in cerebral resistance artery cells. PMID:9746518
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... left-hand fuel pump of the center wing tank (CWT) to shut off after being selected ``OFF'' by the... original NPRM will not be extended to the main wing tanks, as discussed in meetings between Boeing and the... wing tanks on Model 737-600, -700, -700C, -800, and -900 series airplanes to support the proposed AD...
2013-01-01
Background Given their frequency of occurrence in the United States, cancer and heart disease often coexist. For patients requiring open-heart surgery, this raises concern that the use of cardiopulmonary bypass (CPB) may cause a transient immunosuppression with the potential to promote the spread and growth of coexisting cancer cells. This study examined the association of cardiopulmonary bypass with cancer progression in a large population-based setting using linked data from several state-wide registries. Methods A retrospective cohort study of cancer risk, stage, and mortality in 43,347 patients who underwent coronary artery bypass graft (CABG) surgery with and without CPB in New Jersey between 1998–2004 was conducted. A competing risk analogue of the Cox proportional hazards model with propensity score adjustment and regression on the cause-specific hazard was used to compute relative risk ratios (95% confidence intervals [CIs]) for patients undergoing CABG surgery with and without CPB. Results An increased risk for overall cancer incidence (17%) and cancer-specific mortality (16% overall, 12% case fatality) was observed; yet these results did not reach statistical significance. Of 11 tumor-specific analyses, an increased risk of skin melanoma (1.66 [95% CI, 1.08-2.55: p=0.02]) and lung cancer (1.36 [95% CI, 1.02-1.81: p=0.03]) was observed for patients with pump versus off-pump open-heart surgery. No association was found with cancer stage. Conclusions These results suggest that there may be a relationship between CPB and cancer progression. However, if real, the effect is likely modest at most. Further research may still be warranted with particular focus on skin melanoma and lung cancer which had the strongest association with CPB. PMID:24180710
Pinto, Cathy Anne; Marcella, Stephen; August, David A; Holland, Bart; Kostis, John B; Demissie, Kitaw
2013-11-03
Given their frequency of occurrence in the United States, cancer and heart disease often coexist. For patients requiring open-heart surgery, this raises concern that the use of cardiopulmonary bypass (CPB) may cause a transient immunosuppression with the potential to promote the spread and growth of coexisting cancer cells. This study examined the association of cardiopulmonary bypass with cancer progression in a large population-based setting using linked data from several state-wide registries. A retrospective cohort study of cancer risk, stage, and mortality in 43,347 patients who underwent coronary artery bypass graft (CABG) surgery with and without CPB in New Jersey between 1998-2004 was conducted. A competing risk analogue of the Cox proportional hazards model with propensity score adjustment and regression on the cause-specific hazard was used to compute relative risk ratios (95% confidence intervals [CIs]) for patients undergoing CABG surgery with and without CPB. An increased risk for overall cancer incidence (17%) and cancer-specific mortality (16% overall, 12% case fatality) was observed; yet these results did not reach statistical significance. Of 11 tumor-specific analyses, an increased risk of skin melanoma (1.66 [95% CI, 1.08-2.55: p=0.02]) and lung cancer (1.36 [95% CI, 1.02-1.81: p=0.03]) was observed for patients with pump versus off-pump open-heart surgery. No association was found with cancer stage. These results suggest that there may be a relationship between CPB and cancer progression. However, if real, the effect is likely modest at most. Further research may still be warranted with particular focus on skin melanoma and lung cancer which had the strongest association with CPB.
Titov, V N; Dmitriev, V A
2015-03-01
The non-specific systemic biological reaction of arterial pressure from the level of organism. vasomotor center and proximal section of arterial bloodstream is appealed to compensate disorders of metabolism and microcirculation in distal section of arteries. This phenomenon occurs in several cases. The primarily local disorders of metabolism at autocrine level, physiological (aphysiological) death of cells, "littering" of intercellular medium become the cause of disorder of microcirculation in paracrin cenosises and deteriorate realization of biological functions of homeostasis, trophology, endoecology and adaptation. The local compensation of affected perfusion in paracrin cenosises at the expense of function of peripheral peristaltic pumps, redistribution of local bloodflow in biological reaction of endothelium-depended vaso-dilation has no possibility to eliminate disorders in realization of biological functions. The systemic increase of arterial pressure under absence of specific symptoms of symptomatic arterial hypertension is a test to detect disorder of biological functions of homeostasis, trophology, biological function of endoecology and adaptation. Allforms of arterial hypertension develop by common algorithm independently from causes of disorders of blood flow, microcirculation in distal section of arteries. The non-specific systemic compensation ofdisorders of metabolism from level of organism, in proximal section of arterial bloodstream always is the same one and results in aphysiological alterations in organs-targets. To comprehend etiological characteristics of common pathogenesis of arterial hypertension is possible in case of application of such technically complicated and still unclear in differential diagnostic of deranged functions modes of metabolomics.
Lisy, M; Schmid, E; Kozok, J; Rosenberger, P; Stock, U A; Kalender, G
2016-01-01
Intraoperative allogeneic blood product transfusion (ABPT) in cardiac surgery is associated with worse overall outcome, including mortality. The objective of this study was to evaluate the ABPTs in minimalized extracorporeal cardiopulmonary (MECC(TM)) compared with standard open system on-pump coronary revascularization. Data of 156 patients undergoing myocardial revascularization between September 2008 and September 2010 were reviewed. 83 patients were operated by the MECC technique and 73 were treated by standard extracorporeal circulation (sECC). ABPT and overall early postoperative complications were analyzed. Operative mortality and morbidity were similar in both groups. ABPT in the MECC group was significantly lower than in the sECC group both intraoperatively (7.2 vs. 60.3% of patients p<0.001) and during the first five postoperative days (19.3 vs. 57.5%; p<0.001). "Skin to skin"- (214 ± 45 vs. 232 ± 45 min; p=0.012), cardiopulmonary bypass (CPB) - (82 ± 25 vs. 95 ± 26 min; p=0.014), and X-clamp- times (50 ± 16 vs. 56 ± 17 min; p=0.024) were significantly lower in the MECC group than in the sECC group. Length of ICU (intensive care unit) - and hospital stay were also significantly lower in the MECC group vs. the sECC group (26.7 ± 20.2 vs. 54.5 ± 68.9 h; p<0.001, and 12.0 ± 4.1 vs. 14.5 ± 4.6 days; p<0.001). Application of MECC as on-pump coronary artery bypass graft (CABG) results in significantly lower ABPT as well as shorter ICU and in-hospital stay. In order to achieve these benefits of MECC autologous retrograde priming, Bispectral index (BIS) monitoring, intraoperative cell salvage, meticulous hemostasis and strict peri- and postoperative volume management are crucial.
2014-01-01
Background The addition of an intra-aortic balloon pump (IABP) during peripheral venoarterial extracorporeal membrane oxygenation (VA ECMO) support has been shown to improve coronary bypass graft flows and cardiac function in refractory cardiogenic shock after cardiac surgery. The purpose of this study was to evaluate the impact of additional IABP support on the cerebral blood flow (CBF) in patients with peripheral VA ECMO following cardiac procedures. Methods Twelve patients (mean age 60.40 ± 9.80 years) received VA ECMO combined with IABP support for postcardiotomy cardiogenic shock after coronary artery bypass grafting. The mean CBF in the bilateral middle cerebral arteries was measured with and without IABP counterpulsation by transcranial Doppler. The patients provided their control values. The mean CBF data were divided into two groups (pulsatile pressure greater than 10 mmHg, P group; pulsatile pressure less than 10 mmHg, N group) based on whether the patients experienced cardiac stun. The mean cerebral blood flow in VA ECMO (IABP turned off) alone and VA ECMO with IABP support were compared using the paired t test. Results All of the patients were successfully weaned from VA ECMO, and eight patients survived to discharge. The addition of IABP to VA ECMO did not change the mean CBF (251.47 ± 79.28 ml/min vs. 251.30 ± 79.47 ml/min, P = 0.96). The mean CBF was higher in VA ECMO alone than in VA ECMO combined with IABP support in the N group (257.68 ± 97.21 ml/min vs. 239.47 ± 95.60, P = 0.00). The addition of IABP to VA ECMO support increased the mean CBF values significantly compared with VA ECMO alone (261.68 ± 82.45 ml/min vs. 244.43 ± 45.85 ml/min, P = 0.00) in the P group. Conclusion These results demonstrate that an IABP significantly changes the CBF during peripheral VA ECMO, depending on the antegrade blood flow by spontaneous cardiac function. The addition of an IABP to VA ECMO support decreased the CBF during cardiac stun, and it increased CBF without cardiac stun. PMID:24766774
He, S; Liu, Y; Chen, Y; Tang, Y; Xu, J; Tang, C
2016-05-01
Chest pain experienced by patients with coronary artery disease can be partly due to gastroesophageal reflux-induced chest pain (GERP). Empirical proton pump inhibitor (PPI) therapy has been recommended as an initial clinical approach for treating GERP. However, PPI use may lead to some health problems. The Gastroesophageal Reflux Disease Questionnaire (GerdQ) may represent a noninvasive and cost-effective approach for avoiding PPI misuse and for identifying the appropriate patients for the PPI trial test. The aim of this pilot study was to prospectively evaluate the association between GerdQ scores and PPI response in patients with coronary artery disease (CAD) and GERP to determine whether the GerdQ predicts the PPI response in patients with CAD and GERP and to further validate the clinical application value of the GerdQ. A total of 154 consecutive patients with potential GERP were recruited to complete a GerdQ with subsequent PPI therapy. Based on the PPI trial result, patients were divided into a PPI-positive response group and a PPI-negative response group. The difference in the GerdQ scores between the two groups was assessed. The receiver operating characteristic (ROC) curve of GerdQ score was drawn according to the PPI response as the gold standard. The ability of GerdQ to predict the PPI response was assessed. A total of 96 patients completed the entire study; 62 patients (64.6%) were assigned to the PPI-positive response group, and 34 patients (35.4%) to the PPI-negative response group. The GerdQ score of the PPI-positive response group (8.11 ± 3.315) was significantly higher than that of the PPI-negative response group (4.41 ± 2.743), and the difference was statistically significant (t = 5.863, P = 0.000). The ROC curve was drawn according to a PPI response assessment result with a score above 2 as the gold standard. The area under curve was 0.806. When the critical value of GerdQ score was 7.5, Youden index was up to 0.514, the diagnostic sensitivity was 0.661, and the diagnostic specificity was 0.853. A GerdQ score greater than 7.5 better predicts the response to the PPI trial therapy. There is a strong association between the GerdQ score and the response to PPI therapy. Higher GerdQ scores were predictive of a positive PPI response in CAD patients with GERP. The GerdQ may be a reasonable screening tool for GERP in patients with CAD who are prepared to accept PPI therapy. © 2015 International Society for Diseases of the Esophagus.
Left Ventricular Free Wall Rupture in Acute Myocardial Infarction
Amir, Offer; Smith, Ronald; Nishikawa, Akaira; Gregoric, Igor D.; Smart, Frank W.
2005-01-01
We describe a case of subacute left ventricular free wall rupture during acute myocardial infarction in a 68-year-old man. The diagnosis was confirmed by echocardiography. The patient was supported by an intra-aortic balloon pump until the ruptured wall could be successfully repaired by suturing and gluing a pericardial patch over the defect and bypassing the left anterior descending coronary artery with a vein graft. This case demonstrates that left ventricular free wall rupture is not always fatal and that early diagnosis and institution of intra-aortic balloon pump support in such patients can allow successful bridging to definitive emergency surgical therapy. PMID:16392235
Safaei, Naser; Babaei, Hossein; Azarfarin, Rasoul; Jodati, Ahmad-Reza; Yaghoubi, Alireza; Sheikhalizadeh, Mohammad-Ali
2017-01-01
This study aimed to test the beneficial effect of grape seed extract (GSE) (Vitis vinifera) and Vitamin C in oxidative stress and reperfusion injury induced by cardiopulmonary bypass (CPB) in coronary artery bypass surgery. In this randomized trial, 87 patients undergoing elective and isolated coronary bypass surgery included. The patients were randomly assigned into three groups (n = 29 each): (1) Control group with no treatment, (2) GSE group who received the extract 24 h before operation, 100 mg every 6 h, orally, (3) Vitamin C group who received 25 mg/kg Vitamin C through CPB during surgery. Blood samples were taken from coronary sinus at (T1) just before aortic cross clamp; (T2) just before starting controlled aortic root reperfusion; and (T3) 10 min after root reperfusion. Some clinical parameters and biochemical markers were compared among the groups. There were significant differences in tracheal intubation times, sinus rhythm return, and left ventricular function between treatment groups compared with control (P < 0.05). Total antioxidant capacity was higher (P < 0.05) in both grape seed and Vitamin C groups at T2 and T3 times. In reperfusion period, malondialdehyde level was increased in control group; however, it was significantly lower for the grape seed group (P = 0.04). The differences in the mean levels of superoxide dismutase and glutathione peroxidase among the three groups were not significant (P > 0.05 in all cases). In our patients, GSE and Vitamin C had antioxidative effects and reduced deleterious effects of CPB during coronary artery bypass grafting surgery.
2011-01-01
Background Many patients with coronary artery disease (CAD) have overlapping gastroenterological causes of recurrent chest pain, mainly due to gastroesophageal reflux (GER) and aspirin-induced gastrointestinal tract damage. These symptoms can be alleviated by proton pump inhibitors (PPIs). The study addressed whether omeprazole treatment also affects general health-related quality of life (HRQL) in patients with CAD. Study 48 patients with more than 50% narrowing of the coronary arteries on angiography without clinically overt gastrointestinal symptoms were studied. In a double-blind, placebo-controlled, cross-over study design, patients were randomized to take omeprazole 20 mg bid or a placebo for two weeks, and then crossed over to the other study arm. The SF-36 questionnaire was completed before treatment and again after two weeks of therapy. Results Patients treated with omeprazole in comparison to the subjects taking the placebo had significantly greater values for the SF-36 survey (which relates to both physical and mental health), as well as for bodily pain, general health perception, and physical health. In comparison to the baseline values, therapy with omeprazole led to a significant increase in the three summarized health components: total SF-36; physical and mental health; and in the following detailed health concept scores: physical functioning, limitations due to physical health problems, bodily pain and emotional well-being. Conclusions A double dose of omeprazole improved the general HRQL in patients with CAD without severe gastrointestinal symptoms more effectively than the placebo. PMID:21939510
Ito, Hisato; Mizumoto, Toru; Sawada, Yasuhiro; Fujinaga, Kazuya; Tempaku, Hironori; Yamamoto, Yasunori; Tsutsui, Katsuhiro; Shimpo, Hideto
2017-10-01
The aim of this study was to assess the safety and effectiveness of our selective antegrade brain perfusion (SABP) strategy, which is characterized by moderate hypothermic and low-pressure management under pH-stat using a completely closed cardiopulmonary bypass circuit with a single centrifugal pump. Forty-nine consecutive patients (median age, 74) underwent total aortic arch replacement using a 4-branched graft. SABP was conducted with individual cannulation in all arch vessels. The SABP flow rate was monitored, and the flow rates of each arch vessel were also measured in patients with available data. One patient died of cerebral infarction, and 7 had transient neurological deficits without apparent findings on postoperative imaging studies and without residual sequels at hospital discharge. The operation, cardiopulmonary bypass, cardiac arrest, circulatory arrest and SABP times were 327 min (interquartile range, 292-381), 211 (184-247), 107 (84.8-138.3), 54.0 (48-68) and 137 (114-158), respectively. The total flow of the SABP was 18.1 ml/kg/min (15.7-20.9). The flow rates of the brachiocephalic, the left carotid and the left subclavian arteries were 9.5 ml/kg/min (7.7-11.5), 4.2 (2.8-5.7) and 4.5 (3.7-5.5), respectively. Only the flow rate of the brachiocephalic artery was significantly correlated with the total SABP flow rate (Spearman rank correlation coefficient, r = 0.58, P < 0.01). The moderate hypothermic, high-flow, low-pressure SABP strategy with pH-stat management can be applied in adult aortic surgery; however, the feasibility and effectiveness of this concept need further evaluation in a prospective controlled study. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Anatomical variation of arterial supply to the rabbit stomach.
Ikegami, Reona; Tanimoto, Yoshimasa; Kishimoto, Miori; Shibata, Hideshi
2016-05-03
Gastric stasis is common in rabbits, and gastrotomy may be performed to cure this pathological condition. Detailed descriptions of the arterial supply to the stomach are essential for this surgical operation, but published descriptions are limited. Here, we investigated anatomical variations of the arterial supply to the stomach in 43 New Zealand White rabbits by injecting colored latex into arteries. We observed that the left gastric artery that arose as the second branch from the celiac artery provided 1-3 parietal and 1-3 visceral branches to the stomach, with various branching patterns depending on the case. In 34 of 43 cases, the left gastric artery ended upon entering the gastric wall at the lesser curvature, whereas in the remaining cases, the artery continued as the hepatic artery without entering the gastric wall. The right gastric artery that branched off from the gastroduodenal artery also supplied the lesser curvature sinistrally but did not anastomose with the left gastric artery. In 40 cases, the hepatic artery provided 1-4 pyloric branches. In the fundic region, the short gastric arteries arose from the splenic artery and varied in number from 2 to 6. The right and left gastroepiploic arteries anastomosed to give 2-7 branches to the greater curvature. The results showed that many variations occurred in the arteries supplying the rabbit stomach, suggesting that such variations should be considered when performing veterinary surgical treatments in rabbits.
Maupin, Molly A.
1999-01-01
Pumped withdrawals compose most of the irrigation-water diversions from the Snake River between Upper Salmon Falls and Swan Falls Dams in southwestern Idaho. Pumps at 32 sites along the reach lift water as high as 745 feet to irrigate croplands on plateaus north and south of the river. The number of pump sites at which withdrawals are being continuously measured has been steadily decreasing, from 32 in 1990 to 7 in 1998. A cost-effective and accurate means of estimating annual irrigation-water withdrawals at pump sites that are no longer continuously measured was needed. Therefore, the U.S. Geological Survey began a study in 1998, as part of its Water-Use Program, to determine power-consumption coeffi- cients (PCCs) for each pump site so that withdrawals could be estimated by using electrical powerconsumption and total head data. PCC values for each pump site were determined by using withdrawal data that were measured by the U.S. Geological Survey during 1990–92 and 1994–95, energy data reported by Idaho Power Company during the same period, and total head data collected at each site during a field inventory in 1998. Individual average annual withdrawals for the 32 pump sites ranged from 1,120 to 44,480 acre-feet; average PCC values ranged from 103 to 1,248 kilowatthours per acre-foot. During the 1998 field season, power demand, total head, and withdrawal at 18 sites were measured to determine 1998 PCC values. Most of the 1998 PCC values were within 10 percent of the 5-year average, which demonstrates that withdrawals for a site that is no longer continuously measured can be calculated with reasonable accuracy by using the PCC value determined from this study and annual power-consumption data. K-factors, coefficients that describe the amount of energy necessary to lift water, were determined for each pump site by using values of PCC and total head and ranged from 1.11 to 1.89 kilowatthours per acre-foot per foot. Statistical methods were used to define the relations among PCC values and selected pumpsite characteristics. Multiple correlation analysis between average PCC values and total head, total horsepower, and total number of pumps revealed the strongest correlation was between average PCC and total head. Linear regression of these two variables resulted in a strong coefficient of determination R2=0 .9 86) and a representative K-factor of 1.463. Pump sites were subdivided into two groups on the basis of total head—0 to 300 feet and greater than 300 feet. Regression of average PCC values for eight pump sites with total head less than 300 feet produced a good correlation of determination (R2=0.870) and a representative K-factor of 1.682. The second group consisted of 10 pump sites with total head greater than 300 feet; regression produced a correlation of R2=0.939 and a representative K-factor of 1.405. Data on pump-site characteristics were successfully used to determine individual PCC and K-factor values. Statistical relations between pumpsite characteristics and PCC values were defined and used to determine regression equations that resulted in good coefficients of determination and representative K-factors. The individual PCC values will be used in the future to calculate irrigation- water withdrawals at sites that are no longer continuously measured. The representative K-factors and regression equations will be used to calculate irrigation-water withdrawals at sites that have not been previously measured and where total head and power consumption are known.
[Association of three anatomical variants of the anterior cerebral circulation].
Reyes-Soto, Gervith; Pérez-Cruz, Julio; Delgado-Reyes, Luis; Ortega-Gutiérrez, César; Téllez-Palacios, Daniela
2012-01-01
As part of a study of the microsurgical anatomy of the pericallosal artery, we describe one brain with three unusual anatomical variants. From the autopsy of a 45 year-old female, we extracted the brain and all the arterial blood vessels were washed off with saline solution to be injected afterwards with red latex. The brain was then immersed in 10% formalin for two months. Finally, we dissected and measured the internal carotid artery segments, using a digital Vernier caliper under a Carl Zeiss OPMI surgical microscope with magnification of 6x up to 40x. The brain's weight was 1250 grams and three rare anatomical variants were found: 1) right accessory middle cerebral artery (ACMA-d), 2) right bihemispheric anterior cerebral artery (ACABihem-d), 3) median artery of the corpus callosum (AMCC). The association of the anatomical variations described previously is inconstant; furthermore, their appearance in a single case is rare.
Embolization of a large, symptomatic splenic artery pseudoaneurysm
Kukliński, Adam; Batycki, Krzysztof; Matuszewski, Wiesław; Ostrach, Andrzej; Kupis, Zbigniew; Łęgowik, Tomasz
2014-01-01
Summary Background Splenic artery aneurysm is the third most common abdominal aneurysm. Most often it is due to pancreatitis. There were only 19 cases of aneurysms larger than 5 cm in diameter described in the literature. Management of splenic artery aneurysms depends on the size and symptoms. Invasive treatment modalities involve open procedures and interventional radiology methods (endovascular). Case Reports A 44-years-old male with chronic pancreatitis, in a gradually worsening general condition due to a large splenic artery aneurysm, was subjected to the procedure. Blood flow through the aneurysm was cut-off by implanting a covered stent between celiac trunk and common hepatic artery. Patient’s general condition rapidly improved, allowing discharge home in good state soon after the procedure. Conclusions Percutaneous embolization appears to be the best method of treatment of large splenic artery aneurysms. Complications of such treatment are significantly less dangerous than those associated with surgery. PMID:25009678
High-speed off-axis holographic cinematography with a copper-vapor-pumped dye laser.
Lauterborn, W; Judt, A; Schmitz, E
1993-01-01
A series of coherent light pulses is generated by pumping a dye laser with the pulsed output of a copper-vapor laser at rates of as much as 20 kHz. Holograms are recorded at this pulse rate on a rotating holographic plate. This technique of high-speed holographic cinematography is demonstrated by viewing the bubble filaments that appear in water under the action of a sound field of high intensity.
Process Options for Nominal 2-K Helium Refrigeration System Designs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peter Knudsen, Venkatarao Ganni
Nominal 2-K helium refrigeration systems are frequently used for superconducting radio frequency and magnet string technologies used in accelerators. This paper examines the trade-offs and approximate performance of four basic types of processes used for the refrigeration of these technologies; direct vacuum pumping on a helium bath, direct vacuum pumping using full or partial refrigeration recovery, cold compression, and hybrid compression (i.e., a blend of cold and warm sub-atmospheric compression).
Daralammouri, Yunis; Ghannam, Malik; Lauer, Bernward
2016-08-02
A normal anatomy of coronary arteries is important to have adequate cardiac muscle blood supply especially during extraneous physical activities. This case report describes a rare coronary anomaly in which the accessory coronary artery arose from the right coronary artery, reentered the left anterior descending coronary artery, and then ran as a single vessel. We present a case of a coronary anomaly in a 47-year-old white man who presented with atypical angina. Computed tomographic angiography and coronary angiography showed a variant of dual left anterior descending coronary artery not previously described. Our patient's accessory coronary artery arose from his right coronary artery. It took an intramuscular course beneath the right ventricular outflow tract in the interventricular septal area to the anterior interventricular sulcus, giving off septal perforators that reentered his medial left anterior descending coronary artery. Both vessels ran after the anastomosis in the anterior interventricular sulcus as a single vessel. We propose that this anomaly represents a new variant of coronary artery anomaly. This coronary artery anomaly does not cause ischemia. Recognition of this coronary anomaly is important in patients undergoing percutaneous coronary intervention or coronary artery bypass graft operations.
Matsumoto, Takatsugu; Kubota, Keiichi; Aoki, Taku; Shimizu, Takayuki; Mori, Shozo; Kato, Masato; Asato, Hirotaka
2018-02-07
Because of the anatomical characteristics, pancreatic cancers (PC) can easily invade to visceral vessels such as celiac artery, superior mesenteric artery, common hepatic artery (CHA) and portal vein, which makes curative resection difficult. In this study, we report an R0 resection for locally advanced PC by total pancreatectomy, combined resection of CHA, and reconstruction of hepatic artery using autologous left inferior phrenic artery (IPA). A 47-year-old woman with complaints of low back pain was referred to our department. Contrast-enhanced computed tomography revealed a hypo-attenuation tumor of the pancreatic body measuring 70 mm, which completely encased the CHA. When unresectable locally advanced PC was diagnosed, systematic chemotherapy was administrated. After downstaging, she underwent surgery with curative intent. The tumor completely infiltrated the peripheral part of the CHA and gastroduodenal artery. As the tumor also extended to the head of the pancreas, total pancreatectomy and combined resection of CHA were performed. Then the exposed left IPA and proper hepatic artery were anastomosed with a microvascular technique. R0 resection was performed for restoring hepatic arterial flow and the postoperative course was uneventful without any postoperative morbidity. Hepatic artery reconstruction using IPA is a simple and safe procedure in selected patients. © 2018 S. Karger AG, Basel.
Remediation System Evaluation, Raymark Superfund Site (PDF)
The Raymark site occupies 7 acres off Jacksonville Road in an industrial part of Hatboro, Pennsylvania.The pump-and-treat system addresses groundwater contamination, primarily trichloroethylene (TCE),associated with the operations of various ...
Voll, Juliana; Campos, Rui
2016-08-01
Thirty turtle brains (Trachemys scripta elegans) were injected with latex to systematize and describe the internal carotid arteries and their main ramifications at the brain base. The internal carotid arteries had one intercarotid anastomosis. At the level of the tuber cinereum, the internal carotid artery bifurcated into its terminal branches, the rostral and the caudal branches. The rostral branch emitted the rostral choroid artery, the orbital artery, and a series of middle cerebral arteries. After giving off the last middle cerebral artery, the rostral branch continued as the rostral cerebral artery in the cerebral longitudinal fissure, and had one anastomosis with its contralateral homologous artery, the rostral communicating artery, making the first rostral closure of the cerebral arterial circle. Next, the rostral cerebral arteries anastomosed forming a rostral interhemispheric artery, making the second rostral closure of the cerebral arterial circle. The internal carotid artery, after emitting its rostral branch, continued caudally as the caudal branch. The caudal branch ran caudally along the ventral surface of the mesencephalic tegmentum, emitted the caudal cerebral artery and the mesencephalic artery, and continued caudomedially while progressively narrowing, and anastomosed with its contralateral homologous artery, forming the basilar artery. The narrower portion also emitted the trigeminal artery. The anastomosis of the caudal branches closed the cerebral arterial circle caudally. The internal carotid arteries exclusively supplied the cerebral arterial circle of the turtle. Anat Rec, 299:1090-1098, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
RAPID REMOVAL OF A GROUNDWATER CONTAMINANT PLUME.
Lefkoff, L. Jeff; Gorelick, Steven M.; ,
1985-01-01
A groundwater management model is used to design an aquifer restoration system that removes a contaminant plume from a hypothetical aquifer in four years. The design model utilizes groundwater flow simulation and mathematical optimization. Optimal pumping and injection strategies achieve rapid restoration for a minimum total pumping cost. Rapid restoration is accomplished by maintaining specified groundwater velocities around the plume perimeter towards a group of pumping wells located near the plume center. The model does not account for hydrodynamic dispersion. Results show that pumping costs are particularly sensitive to injection capacity. An 8 percent decrease in the maximum allowable injection rate may lead to a 29 percent increase in total pumping costs.
Wróbel, Krzysztof; Kurnicka, Katarzyna; Zygier, Marcin; Dyk, Wojciech; Wojdyga, Ryszard; Zieliński, Dariusz; Jarzębska, Małgorzata; Juraszyński, Zbigniew; Lichodziejewska, Barbara; Pruszczyk, Piotr; Biederman, Andrzej; Speziali, Giovanni; Kasten, Uwe
2017-01-01
Artificial chord implantation to repair a flail or prolapsing mitral valve leaflet requires open heart surgery and cardiopulmonary bypass. Transapical off-pump artificial chordae implantation is a new surgical technique proposed to treat degenerative mitral valve regurgitation. The procedure is performed using the NeoChord DS1000 system (NeoChord, Inc., St. Louis Park, MN, USA), which facilitates both implantation and lenght adjustment of the artificial chordae under two (2D)- and three (3D)-dimensional transoesophageal echocardiographic (TEE) guidance on a beating heart. Two male patients aged 60 and 55 years with severe mitral regurgitation due to posterior leaflet prolapse underwent transapical off-pump artificial chordae implantation on September 3, 2015. The procedure was performed by left minithoracotomy under general anaesthesia in a cardiac surgical theatre, using 2D and 3D TEE guidance. Early procedural success as confirmed by 3D TEE was achieved in both patients, with implantation of 6 artificial chordae in the first patient and 3 artificial chordae in the second patient. Both procedures were uneventful, and no postoperative complications were noted. The patients were discharged home on the 8th and 6th postoperative day, respectively. The NeoChord DS1000 system allows both implantation and lenght adjustment of artificial chordae under 2D and 3D TEE guidance on a beating heart. Our initial experience in 2 patients with posterior mitral leaflet prolapse indicates that the procedure is feasible and safe.