Multiprocessor switch with selective pairing
Gara, Alan; Gschwind, Michael K; Salapura, Valentina
2014-03-11
System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switch or a bus
Flitter, Marc A; Riesenmy, Kelly Rouse; van Stralen, Daved
2012-01-01
To offer a theoretical explanation for observed physician resistance and rejection of high reliability patient safety initiatives. A grounded theoretical qualitative approach, utilizing the organizational theory of sensemaking, provided the foundation for inductive and deductive reasoning employed to analyze medical staff rejection of two successfully performing high reliability programs at separate hospitals. Physician behaviors resistant to patient-centric high reliability processes were traced to provider-centric physician sensemaking. Research, conducted with the advantage that prospective studies have over the limitations of this retrospective investigation, is needed to evaluate the potential for overcoming physician resistance to innovation implementation, employing strategies based upon these findings and sensemaking theory in general. If hospitals are to emulate high reliability industries that do successfully manage environments of extreme hazard, physicians must be fully integrated into the complex teams required to accomplish this goal. Reforming health care, through high reliability organizing, with its attendant continuous focus on patient-centric processes, offers a distinct alternative to efforts directed primarily at reforming health care insurance. It is by changing how health care is provided that true cost efficiencies can be achieved. Technology and the insights of organizational science present the opportunity of replacing the current emphasis on privileged information with collective tools capable of providing quality and safety in health care. The fictions that have sustained a provider-centric health care system have been challenged. The benefits of patient-centric care should be obtainable.
ERIC Educational Resources Information Center
Abry, Tashia; Cash, Anne H.; Bradshaw, Catherine P.
2014-01-01
Generalizability theory (GT) offers a useful framework for estimating the reliability of a measure while accounting for multiple sources of error variance. The purpose of this study was to use GT to examine multiple sources of variance in and the reliability of school-level teacher and high school student behaviors as observed using the tool,…
Challenges for Wireless Mesh Networks to provide reliable carrier-grade services
NASA Astrophysics Data System (ADS)
von Hugo, D.; Bayer, N.
2011-08-01
Provision of mobile and wireless services today within a competitive environment and driven by a huge amount of steadily emerging new services and applications is both challenge and chance for radio network operators. Deployment and operation of an infrastructure for mobile and wireless broadband connectivity generally requires planning effort and large investments. A promising approach to reduce expenses for radio access networking is offered by Wireless Mesh Networks (WMNs). Here traditional dedicated backhaul connections to each access point are replaced by wireless multi-hop links between neighbouring access nodes and few gateways to the backbone employing standard radio technology. Such a solution provides at the same time high flexibility in both deployment and the amount of offered capacity and shall reduce overall expenses. On the other hand currently available mesh solutions do not provide carrier grade service quality and reliability and often fail to cope with high traffic load. EU project CARMEN (CARrier grade MEsh Networks) was initiated to incorporate different heterogeneous technologies and new protocols to allow for reliable transmission over "best effort" radio channels, to support a reliable mobility and network management, self-configuration and dynamic resource usage, and thus to offer a permanent or temporary broadband access at high cost efficiency. The contribution provides an overview on preliminary project results with focus on main technical challenges from a research and implementation point of view. Especially impact of mesh topology on the overall system performance in terms of throughput and connection reliability and aspects of a dedicated hybrid mobility management solution will be discussed.
Comparing Validity and Reliability in Special Education Title II and IDEA Data
ERIC Educational Resources Information Center
Steinbrecher, Trisha D.; McKeown, Debra; Walther-Thomas, Chriss
2013-01-01
Previous researchers have found that special education teacher shortages are pervasive and exacerbated by federal policies regarding "highly qualified" teacher requirements. The authors examined special education teacher personnel data from 2 federal data sources to determine if these sources offer a reliable and valid means of…
Preliminary study of the reliability of imaging charge coupled devices
NASA Technical Reports Server (NTRS)
Beall, J. R.; Borenstein, M. D.; Homan, R. A.; Johnson, D. L.; Wilson, D. D.; Young, V. F.
1978-01-01
Imaging CCDs are capable of low light level response and high signal-to-noise ratios. In space applications they offer the user the ability to achieve extremely high resolution imaging with minimum circuitry in the photo sensor array. This work relates the CCD121H Fairchild device to the fundamentals of CCDs and the representative technologies. Several failure modes are described, construction is analyzed and test results are reported. In addition, the relationship of the device reliability to packaging principles is analyzed and test data presented. Finally, a test program is defined for more general reliability evaluation of CCDs.
The military operator's experience of reliability and maintainability characteristics
NASA Astrophysics Data System (ADS)
Jones, R. Mcc.
An account is given of the British Army's approach to the achievement of high reliability and maintainability in rotorcraft during the procurement process. Attention is given to experience accumulated to date with the Gazelle, Scout, Agusta A109A, and Lynx helicopters; these offer lessons with respect to the Gem engine, fuel filtering, vibration, and an aircraft flight control system.
Murphy, Douglas J; Bruce, David A; Mercer, Stewart W; Eva, Kevin W
2009-05-01
To investigate the reliability and feasibility of six potential workplace-based assessment methods in general practice training: criterion audit, multi-source feedback from clinical and non-clinical colleagues, patient feedback (the CARE Measure), referral letters, significant event analysis, and video analysis of consultations. Performance of GP registrars (trainees) was evaluated with each tool to assess the reliabilities of the tools and feasibility, given raters and number of assessments needed. Participant experience of process determined by questionnaire. 171 GP registrars and their trainers, drawn from nine deaneries (representing all four countries in the UK), participated. The ability of each tool to differentiate between doctors (reliability) was assessed using generalisability theory. Decision studies were then conducted to determine the number of observations required to achieve an acceptably high reliability for "high-stakes assessment" using each instrument. Finally, descriptive statistics were used to summarise participants' ratings of their experience using these tools. Multi-source feedback from colleagues and patient feedback on consultations emerged as the two methods most likely to offer a reliable and feasible opinion of workplace performance. Reliability co-efficients of 0.8 were attainable with 41 CARE Measure patient questionnaires and six clinical and/or five non-clinical colleagues per doctor when assessed on two occasions. For the other four methods tested, 10 or more assessors were required per doctor in order to achieve a reliable assessment, making the feasibility of their use in high-stakes assessment extremely low. Participant feedback did not raise any major concerns regarding the acceptability, feasibility, or educational impact of the tools. The combination of patient and colleague views of doctors' performance, coupled with reliable competence measures, may offer a suitable evidence-base on which to monitor progress and completion of doctors' training in general practice.
Tests Of A Stirling-Engine Power Converter
NASA Technical Reports Server (NTRS)
Dochat, George
1995-01-01
Report describes acceptance tests of power converter consisting of pair of opposed free-piston Stirling engines driving linear alternators. Stirling engines offer potential for extremely long life, high reliability, high efficiency at low hot-to-cold temperature ratios, and relatively low heater-head temperatures.
High day-to-day reliability in lower leg volume measured by water displacement.
Pasley, Jeffrey D; O'Connor, Patrick J
2008-07-01
The day-to-day reliability of lower leg volume is poorly documented. This investigation determined the day-to-day reliability of lower leg volume (soleus and gastrocnemius) measured using water displacement. Thirty young adults (15 men and 15 women) had their right lower leg volume measured by water displacement on five separate occasions. The participants performed normal activities of daily living and were measured at the same time of day after being seated for 30 min. The results revealed a high day-to-day reliability for lower leg volume. The mean percentage change in lower leg volume across days compared to day 1 ranged between 0 and 0.37%. The mean within subjects coefficient of variation in lower leg volume was 0.72% and the coefficient of variation for the entire sample across days ranged from 5.66 to 6.32%. A two way mixed model intraclass correlation (30 subjects x 5 days) showed that the lower leg volume measurement was highly reliable (ICC = 0.972). Foot and total lower leg volumes showed similarly high reliability. Water displacement offers a cost effective and reliable solution for the measurement of lower leg edema across days.
ERIC Educational Resources Information Center
Bunnell, Tristan
2011-01-01
The International Baccalaureate[R] (IB) world, known as "the IB World," is doubling in size every five years. The IB has become a complex educational product, but offers high levels of consistency and reliability in terms of delivery and assessment. However, since late 2008, a number of concerns have been raised about the quality and manageability…
Design of ultra high performance concrete as an overlay in pavements and bridge decks.
DOT National Transportation Integrated Search
2014-08-01
The main objective of this research was to develop ultra-high performance concrete (UHPC) as a reliable, economic, low carbon foot : print and durable concrete overlay material that can offer shorter traffic closures due to faster construction. The U...
Solid-Body Fuse Developed for High- Voltage Space Power Missions
NASA Technical Reports Server (NTRS)
Dolce, James L.; Baez, Anastacio N.
2001-01-01
AEM Incorporated has completed the development, under a NASA Glenn Research Center contract, of a solid-body fuse for high-voltage power systems of satellites and spacecraft systems. High-reliability fuses presently defined by MIL-PRF-23419 do not meet the increased voltage and amperage requirements for the next generation of spacecraft. Solid-body fuses exhibit electrical and mechanical attributes that enable these fuses to perform reliably in the vacuum and high-vibration and -shock environments typically present in spacecraft applications. The construction and screening techniques for solid-body fuses described by MIL-PRF-23419/12 offer an excellent roadmap for the development of high-voltage solid-body fuses.
High Sensitivity Gas Detection Using a Macroscopic Three-Dimensional Graphene Foam Network
Yavari, Fazel; Chen, Zongping; Thomas, Abhay V.; Ren, Wencai; Cheng, Hui-Ming; Koratkar, Nikhil
2011-01-01
Nanostructures are known to be exquisitely sensitive to the chemical environment and offer ultra-high sensitivity for gas-sensing. However, the fabrication and operation of devices that use individual nanostructures for sensing is complex, expensive and suffers from poor reliability due to contamination and large variability from sample-to-sample. By contrast, conventional solid-state and conducting-polymer sensors offer excellent reliability but suffer from reduced sensitivity at room-temperature. Here we report a macro graphene foam-like three-dimensional network which combines the best of both worlds. The walls of the foam are comprised of few-layer graphene sheets resulting in high sensitivity; we demonstrate parts-per-million level detection of NH3 and NO2 in air at room-temperature. Further, the foam is a mechanically robust and flexible macro-scale network that is easy to contact (without Lithography) and can rival the durability and affordability of traditional sensors. Moreover, Joule-heating expels chemisorbed molecules from the foam's surface leading to fully-reversible and low-power operation. PMID:22355681
High-Reliability Health Care: Getting There from Here
Chassin, Mark R; Loeb, Jerod M
2013-01-01
Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. PMID:24028696
High-reliability health care: getting there from here.
Chassin, Mark R; Loeb, Jerod M
2013-09-01
Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. © 2013 The Authors. The Milbank Quarterly published by Wiley Periodicals Inc. on behalf of Milbank Memorial Fund.
State recovery and lockstep execution restart in a system with multiprocessor pairing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gara, Alan; Gschwind, Michael K; Salapura, Valentina
System, method and computer program product for a multiprocessing system to offer selective pairing of processor cores for increased processing reliability. A selective pairing facility is provided that selectively connects, i.e., pairs, multiple microprocessor or processor cores to provide one highly reliable thread (or thread group). Each paired microprocessor or processor cores that provide one highly reliable thread for high-reliability connect with a system components such as a memory "nest" (or memory hierarchy), an optional system controller, and optional interrupt controller, optional I/O or peripheral devices, etc. The memory nest is attached to a selective pairing facility via a switchmore » or a bus. Each selectively paired processor core is includes a transactional execution facility, whereing the system is configured to enable processor rollback to a previous state and reinitialize lockstep execution in order to recover from an incorrect execution when an incorrect execution has been detected by the selective pairing facility.« less
Sexual behaviors among club drug users: prevalence and reliability
Shacham, Enbal; Cottler, Linda B.
2013-01-01
HIV prevention efforts require a focus on reducing high risk sexual behavior. Because these are self-reported, assessments that reduce memory bias and improve elicitation of data are needed. As part of a multi-site psychometric study of club drug use, abuse, and dependence, data were collected with a test-retest design that measured the reliability of the Washington University Risk Behavior Assessment for Club Drugs (WU-RBA-CD). Reliability was assessed separately by sex via kappa coefficients and intraclass correlation coefficients (ICC); z tests compared coefficients by sex. A total of 603 participants were interviewed by independent assessors with 5 days in between interviews. Reliability for all 51 items of the sexual activity section of the WU-RBA-CD ranged from .23 to 1.00; 71% (n = 36) of items resulted in moderate to high reliability (.55–1.00). Number of lifetime sex partners was consistently reported for same-sex partners for both men and women and opposite-sex partners. Items with high reliability included reporting ever being under the influence of ecstasy (.87) or GHB (.87) while having sex. Items with lower reliability included those that queried the determinants of condom use (.45–.82) and about behaviors and attitudes experienced while using drugs (.23–.87). Very few sex differences were revealed in the reliability of reported sexual activities. Overall, the WU-RBA-CD performed with fairly high reliability rates. Assessing situations of when, how, and why individuals use condoms may offer the clearest evaluation of determinants of sexual behaviors, yet those items are not as reliable. PMID:19757011
Unified Communications for Space Inventory Management
NASA Technical Reports Server (NTRS)
Gifford, Kevin K.; Fink, Patrick W.; Barton, Richard; Ngo, Phong H.
2009-01-01
To help assure mission success for long-duration exploration activities, NASA is actively pursuing wireless technologies that promote situational awareness and autonomy. Wireless technologies are typically extensible, offer freedom from wire tethers, readily support redundancy, offer potential for decreased wire weight, and can represent dissimilar implementation for increased reliability. In addition, wireless technologies can enable additional situational awareness that otherwise would be infeasible. For example, addition of wired sensors, the need for which might not have been apparent at the outset of a program, night be extremely costly due in part to the necessary routing of cables through the vehicle. RFID, or radio frequency identification, is a wireless technology with the potential for significant savings and increased reliability and safety in space operations. Perhaps the most obvious savings relate to the application of inventory management. A fully automated inventory management system is highly desirable for long-term sustaining operations in space environments. This assertion is evidenced by inventory activities on the International Space Station, which represents the most extensive inventory tracking experience base in the history of space operations. In the short tern, handheld RFID readers offer substantial savings owing to reduced crew time for inventory audits. Over the long term, a combination of improved RFID technology and operational concepts modified to fully utilize the technology should result in space based inventory management that is highly reliable and requires very little crew time. In addition to inventory management, RFID is likely to find space applications in real-time location and tracking systems. These could vary from coarse-resolution RFID portals to the high resolution afforded by ultra-wideband (UWB) RFID. Longer range RFID technologies that leverage passive surface acoustic wave (SAW) devices are being investigated to track assets on a lunar or planetary surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rich Schiferl
2008-05-30
High temperature superconducting (HTS) motors offer the potential for dramatic volume and loss reduction compared to conventional, high horspower, industrial motors. This report is the final report on the results of eight research tasks that address some of the issues related to HTS motor development that affect motor efficiency, cost, and reliability.
Growth of Acousto-Optic Crystals for Applications in Infrared Region of Spectrum
2005-04-30
Acousto - optic (AO) modulators, deflectors, filters offer convenience, reliability, compact size and fast speed in regulation of optical beams. So far...extremely low acousto - optic figure of merit, which automatically results in high requirements on driving electric power and poor diffraction efficiency. It
Choosing a reliability inspection plan for interval censored data
Lu, Lu; Anderson-Cook, Christine Michaela
2017-04-19
Reliability test plans are important for producing precise and accurate assessment of reliability characteristics. This paper explores different strategies for choosing between possible inspection plans for interval censored data given a fixed testing timeframe and budget. A new general cost structure is proposed for guiding precise quantification of total cost in inspection test plan. Multiple summaries of reliability are considered and compared as the criteria for choosing the best plans using an easily adapted method. Different cost structures and representative true underlying reliability curves demonstrate how to assess different strategies given the logistical constraints and nature of the problem. Resultsmore » show several general patterns exist across a wide variety of scenarios. Given the fixed total cost, plans that inspect more units with less frequency based on equally spaced time points are favored due to the ease of implementation and consistent good performance across a large number of case study scenarios. Plans with inspection times chosen based on equally spaced probabilities offer improved reliability estimates for the shape of the distribution, mean lifetime, and failure time for a small fraction of population only for applications with high infant mortality rates. The paper uses a Monte Carlo simulation based approach in addition to the common evaluation based on the asymptotic variance and offers comparison and recommendation for different applications with different objectives. Additionally, the paper outlines a variety of different reliability metrics to use as criteria for optimization, presents a general method for evaluating different alternatives, as well as provides case study results for different common scenarios.« less
Choosing a reliability inspection plan for interval censored data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Lu; Anderson-Cook, Christine Michaela
Reliability test plans are important for producing precise and accurate assessment of reliability characteristics. This paper explores different strategies for choosing between possible inspection plans for interval censored data given a fixed testing timeframe and budget. A new general cost structure is proposed for guiding precise quantification of total cost in inspection test plan. Multiple summaries of reliability are considered and compared as the criteria for choosing the best plans using an easily adapted method. Different cost structures and representative true underlying reliability curves demonstrate how to assess different strategies given the logistical constraints and nature of the problem. Resultsmore » show several general patterns exist across a wide variety of scenarios. Given the fixed total cost, plans that inspect more units with less frequency based on equally spaced time points are favored due to the ease of implementation and consistent good performance across a large number of case study scenarios. Plans with inspection times chosen based on equally spaced probabilities offer improved reliability estimates for the shape of the distribution, mean lifetime, and failure time for a small fraction of population only for applications with high infant mortality rates. The paper uses a Monte Carlo simulation based approach in addition to the common evaluation based on the asymptotic variance and offers comparison and recommendation for different applications with different objectives. Additionally, the paper outlines a variety of different reliability metrics to use as criteria for optimization, presents a general method for evaluating different alternatives, as well as provides case study results for different common scenarios.« less
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.
The Development of a Physical Education Teachers' Physical Activity Self-Efficacy Instrument.
ERIC Educational Resources Information Center
Martin, Jeffrey J.; Kulinna, Pamela Hodges
2003-01-01
Developed a valid, reliable physical education teachers' physical activity self-efficacy scale for teaching classes in which students were engaged in high levels of physical activity. Results offer preliminary support for the psychometric properties of this instrument, which can help understand physical education teachers' efficacy in overcoming…
Evaluation of the efficiency and fault density of software generated by code generators
NASA Technical Reports Server (NTRS)
Schreur, Barbara
1993-01-01
Flight computers and flight software are used for GN&C (guidance, navigation, and control), engine controllers, and avionics during missions. The software development requires the generation of a considerable amount of code. The engineers who generate the code make mistakes and the generation of a large body of code with high reliability requires considerable time. Computer-aided software engineering (CASE) tools are available which generates code automatically with inputs through graphical interfaces. These tools are referred to as code generators. In theory, code generators could write highly reliable code quickly and inexpensively. The various code generators offer different levels of reliability checking. Some check only the finished product while some allow checking of individual modules and combined sets of modules as well. Considering NASA's requirement for reliability, an in house manually generated code is needed. Furthermore, automatically generated code is reputed to be as efficient as the best manually generated code when executed. In house verification is warranted.
Measuring human remains in the field: Grid technique, total station, or MicroScribe?
Sládek, Vladimír; Galeta, Patrik; Sosna, Daniel
2012-09-10
Although three-dimensional (3D) coordinates for human intra-skeletal landmarks are among the most important data that anthropologists have to record in the field, little is known about the reliability of various measuring techniques. We compared the reliability of three techniques used for 3D measurement of human remain in the field: grid technique (GT), total station (TS), and MicroScribe (MS). We measured 365 field osteometric points on 12 skeletal sequences excavated at the Late Medieval/Early Modern churchyard in Všeruby, Czech Republic. We compared intra-observer, inter-observer, and inter-technique variation using mean difference (MD), mean absolute difference (MAD), standard deviation of difference (SDD), and limits of agreement (LA). All three measuring techniques can be used when accepted error ranges can be measured in centimeters. When a range of accepted error measurable in millimeters is needed, MS offers the best solution. TS can achieve the same reliability as does MS, but only when the laser beam is accurately pointed into the center of the prism. When the prism is not accurately oriented, TS produces unreliable data. TS is more sensitive to initialization than is MS. GT measures human skeleton with acceptable reliability for general purposes but insufficiently when highly accurate skeletal data are needed. We observed high inter-technique variation, indicating that just one technique should be used when spatial data from one individual are recorded. Subadults are measured with slightly lower error than are adults. The effect of maximum excavated skeletal length has little practical significance in field recording. When MS is not available, we offer practical suggestions that can help to increase reliability when measuring human skeleton in the field. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Managing Complexity in Next Generation Robotic Spacecraft: From a Software Perspective
NASA Technical Reports Server (NTRS)
Reinholtz, Kirk
2008-01-01
This presentation highlights the challenges in the design of software to support robotic spacecraft. Robotic spacecraft offer a higher degree of autonomy, however currently more capabilities are required, primarily in the software, while providing the same or higher degree of reliability. The complexity of designing such an autonomous system is great, particularly while attempting to address the needs for increased capabilities and high reliability without increased needs for time or money. The efforts to develop programming models for the new hardware and the integration of software architecture are highlighted.
Morrison, Melanie A.; Churchill, Nathan W.; Cusimano, Michael D.; Schweizer, Tom A.; Das, Sunit; Graham, Simon J.
2016-01-01
Background Functional magnetic resonance imaging (fMRI) continues to develop as a clinical tool for patients with brain cancer, offering data that may directly influence surgical decisions. Unfortunately, routine integration of preoperative fMRI has been limited by concerns about reliability. Many pertinent studies have been undertaken involving healthy controls, but work involving brain tumor patients has been limited. To develop fMRI fully as a clinical tool, it will be critical to examine these reliability issues among patients with brain tumors. The present work is the first to extensively characterize differences in activation map quality between brain tumor patients and healthy controls, including the effects of tumor grade and the chosen behavioral testing paradigm on reliability outcomes. Method Test-retest data were collected for a group of low-grade (n = 6) and high-grade glioma (n = 6) patients, and for matched healthy controls (n = 12), who performed motor and language tasks during a single fMRI session. Reliability was characterized by the spatial overlap and displacement of brain activity clusters, BOLD signal stability, and the laterality index. Significance testing was performed to assess differences in reliability between the patients and controls, and low-grade and high-grade patients; as well as between different fMRI testing paradigms. Results There were few significant differences in fMRI reliability measures between patients and controls. Reliability was significantly lower when comparing high-grade tumor patients to controls, or to low-grade tumor patients. The motor task produced more reliable activation patterns than the language tasks, as did the rhyming task in comparison to the phonemic fluency task. Conclusion In low-grade glioma patients, fMRI data are as reliable as healthy control subjects. For high-grade glioma patients, further investigation is required to determine the underlying causes of reduced reliability. To maximize reliability outcomes, testing paradigms should be carefully selected to generate robust activation patterns. PMID:26894279
Nateghi, Roshanak; Guikema, Seth D; Wu, Yue Grace; Bruss, C Bayan
2016-01-01
The U.S. federal government regulates the reliability of bulk power systems, while the reliability of power distribution systems is regulated at a state level. In this article, we review the history of regulating electric service reliability and study the existing reliability metrics, indices, and standards for power transmission and distribution networks. We assess the foundations of the reliability standards and metrics, discuss how they are applied to outages caused by large exogenous disturbances such as natural disasters, and investigate whether the standards adequately internalize the impacts of these events. Our reflections shed light on how existing standards conceptualize reliability, question the basis for treating large-scale hazard-induced outages differently from normal daily outages, and discuss whether this conceptualization maps well onto customer expectations. We show that the risk indices for transmission systems used in regulating power system reliability do not adequately capture the risks that transmission systems are prone to, particularly when it comes to low-probability high-impact events. We also point out several shortcomings associated with the way in which regulators require utilities to calculate and report distribution system reliability indices. We offer several recommendations for improving the conceptualization of reliability metrics and standards. We conclude that while the approaches taken in reliability standards have made considerable advances in enhancing the reliability of power systems and may be logical from a utility perspective during normal operation, existing standards do not provide a sufficient incentive structure for the utilities to adequately ensure high levels of reliability for end-users, particularly during large-scale events. © 2015 Society for Risk Analysis.
NASA Technical Reports Server (NTRS)
Sproles, Darrell W.; Bavuso, Salvatore J.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurie, Carol
2017-02-01
This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Office of Energy Efficiency and Renewable Energy
This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.
NASA Astrophysics Data System (ADS)
Fei, Cheng-Wei; Bai, Guang-Chen
2014-12-01
To improve the computational precision and efficiency of probabilistic design for mechanical dynamic assembly like the blade-tip radial running clearance (BTRRC) of gas turbine, a distribution collaborative probabilistic design method-based support vector machine of regression (SR)(called as DCSRM) is proposed by integrating distribution collaborative response surface method and support vector machine regression model. The mathematical model of DCSRM is established and the probabilistic design idea of DCSRM is introduced. The dynamic assembly probabilistic design of aeroengine high-pressure turbine (HPT) BTRRC is accomplished to verify the proposed DCSRM. The analysis results reveal that the optimal static blade-tip clearance of HPT is gained for designing BTRRC, and improving the performance and reliability of aeroengine. The comparison of methods shows that the DCSRM has high computational accuracy and high computational efficiency in BTRRC probabilistic analysis. The present research offers an effective way for the reliability design of mechanical dynamic assembly and enriches mechanical reliability theory and method.
Optimization of SIS mixer elements
NASA Technical Reports Server (NTRS)
Mattauch, Robert J.
1985-01-01
Superconductor-Insulator-Superconductor (SIS) quantum mixers provide an approach to millimeter wave mixing - potentially offering conversion gain, a low local oscillator power demand, and potential mixer noise temperatures near the quantum limit. The development of a reliable fabrication technology for producing such high quality SIS devices for mixer applications in radio astronomy is the focus of the work.
GPA in Research Studies: An Invaluable but Neglected Opportunity
ERIC Educational Resources Information Center
Bacon, Donald R.; Bean, Beth
2006-01-01
Grade point average (GPA) often correlates highly with variables of interest to educational researchers and thus offers the potential to greatly increase the statistical power of their research studies. Yet this variable is often underused in marketing education research studies. The reliability and validity of the GPA are closely examined here in…
High-reliability gas-turbine combined-cycle development program: Phase II. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. This volume presents information of the reliability, availability, and maintainability (RAM) analysis of a representative plant and the preliminary design of the gas turbine, the gas turbine ancillaries, and the balance of plant including themore » steam turbine generator. To achieve the program goals, a gas turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000 hours. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and mandual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-hour EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricity compared to present market offerings.« less
Oxygen production using solid-state zirconia electrolyte technology
NASA Technical Reports Server (NTRS)
Suitor, Jerry W.; Clark, Douglas J.
1991-01-01
High purity oxygen is required for a number of scientific, medical, and industrial applications. Traditionally, these needs have been met by cryogenic distillation or pressure swing adsorption systems designed to separate oxygen from air. Oxygen separation from air via solid-state zirconia electrolyte technology offers an alternative to these methods. The technology has several advantages over the traditional methods, including reliability, compactness, quiet operation, high purity output, and low power consumption.
Artemiou, E; Adams, C L; Hecker, K G; Vallevand, A; Violato, C; Coe, J B
2014-11-22
In human medicine, standardised patients (SP) have been shown to reliably and accurately assess learners' communication performance in high-stakes certification Objective Structured Clinical Examinations (OSCE), offering a feasible way to reduce the need for recruitment, time commitment and coordination of faculty assessors. In this study, we evaluated the use of standardised clients (SC) as a viable option for assessing veterinary students' communication performance. We designed a four-station, two-track communication skills OSCE. SC assessors used an adapted nine-item Liverpool Undergraduate Communication Assessment Scale (LUCAS). Faculty used a 21-item checklist derived from the Calgary-Cambridge Guide (CCG) and a five-point global rating scale. Participants were second year veterinary students (n=96). For the four stations, intrastation reliability (α) ranged from 0.63 to 0.82 for the LUCAS, and 0.73 to 0.87 for the CCG. The interstation reliability coefficients were 0.85 for the LUCAS and 0.89 for the CGG. The calculated Generalisability (G) coefficients were 0.62 for the LUCAS and 0.60 for the CGG. Supporting construct validity, SC and faculty assessors showed a significant correlation between the LUCAS and CCG total percent scores (r=0.45, P<0.001), and likewise between the LUCAS and global rating scores (r=0.49, P<0.001).Study results support that SC assessors offer a reliable and valid approach for assessing veterinary communication OSCE. British Veterinary Association.
The Use of Cronbach's Alpha When Developing and Reporting Research Instruments in Science Education
NASA Astrophysics Data System (ADS)
Taber, Keith S.
2017-06-01
Cronbach's alpha is a statistic commonly quoted by authors to demonstrate that tests and scales that have been constructed or adopted for research projects are fit for purpose. Cronbach's alpha is regularly adopted in studies in science education: it was referred to in 69 different papers published in 4 leading science education journals in a single year (2015)—usually as a measure of reliability. This article explores how this statistic is used in reporting science education research and what it represents. Authors often cite alpha values with little commentary to explain why they feel this statistic is relevant and seldom interpret the result for readers beyond citing an arbitrary threshold for an acceptable value. Those authors who do offer readers qualitative descriptors interpreting alpha values adopt a diverse and seemingly arbitrary terminology. More seriously, illustrative examples from the science education literature demonstrate that alpha may be acceptable even when there are recognised problems with the scales concerned. Alpha is also sometimes inappropriately used to claim an instrument is unidimensional. It is argued that a high value of alpha offers limited evidence of the reliability of a research instrument, and that indeed a very high value may actually be undesirable when developing a test of scientific knowledge or understanding. Guidance is offered to authors reporting, and readers evaluating, studies that present Cronbach's alpha statistic as evidence of instrument quality.
NASA Astrophysics Data System (ADS)
Rumbaugh, Roy N.; Grealish, Kevin; Kacir, Tom; Arsenault, Barry; Murphy, Robert H.; Miller, Scott
2003-09-01
A new 4th generation MicroIR architecture is introduced as the latest in the highly successful Standard Camera Core (SCC) series by BAE SYSTEMS to offer an infrared imaging engine with greatly reduced size, weight, power, and cost. The advanced SCC500 architecture provides great flexibility in configuration to include multiple resolutions, an industry standard Real Time Operating System (RTOS) for customer specific software application plug-ins, and a highly modular construction for unique physical and interface options. These microbolometer based camera cores offer outstanding and reliable performance over an extended operating temperature range to meet the demanding requirements of real-world environments. A highly integrated lens and shutter is included in the new SCC500 product enabling easy, drop-in camera designs for quick time-to-market product introductions.
Phase-locked telemetry system for rotary instrumentation of turbomachinery, phase 1
NASA Technical Reports Server (NTRS)
Adler, A.; Hoeks, B.
1978-01-01
A telemetry system for use in making strain and temperature measurements on the rotating components of high speed turbomachines employs phase locked transmitters, which offer greater measurement channel capacity and reliability than existing systems which employ L-C carrier oscillators. A prototype transmitter module was tested at 175 C combined with 40,000 g's acceleration.
ERIC Educational Resources Information Center
Hardy, Precious; Aruguete, Mara
2014-01-01
Retention is a major problem in most colleges and universities. High dropout rates, especially in the STEM disciplines (science, technology, engineering and mathematics), have proved intractable despite the offering of supplemental instruction. A broad model of support systems that includes psychological factors is needed to address retention in…
The advantages of the high voltage solar array for electric propulsion
NASA Technical Reports Server (NTRS)
Sater, B. L.
1973-01-01
The high voltage solar array offers improvements in efficiency, weight, and reliability for the electric propulsion power system. Conventional power processes and problems associated with ion thruster operation using SERT 2 experience are discussed and the advantages of the HVSA concept for electric propulsion are presented. Tests conducted operating the SERT 2 thruster system in conjunction with HVSA are reported. Thruster operation was observed to be normal and in some respects improved.
High-reliability gas-turbine combined-cycle development program: Phase II, Volume 3. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. The power plant was addressed in three areas: (1) the gas turbine, (2) the gas turbine ancillaries, and (3) the balance of plant including the steam turbine generator. To achieve the program goals, a gasmore » turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and manual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-h EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricty compared to present market offerings.« less
Dynamic SLA Negotiation in Autonomic Federated Environments
NASA Astrophysics Data System (ADS)
Rubach, Pawel; Sobolewski, Michael
Federated computing environments offer requestors the ability to dynamically invoke services offered by collaborating providers in the virtual service network. Without an efficient resource management that includes Dynamic SLA Negotiation, however, the assignment of providers to customer's requests cannot be optimized and cannot offer high reliability without relevant SLA guarantees. We propose a new SLA-based SERViceable Metacomputing Environment (SERVME) capable of matching providers based on QoS requirements and performing autonomic provisioning and deprovisioning of services according to dynamic requestor needs. This paper presents the SLA negotiation process that includes on-demand provisioning and uses an object-oriented SLA model for large-scale service-oriented systems supported by SERVME. An initial reference implementation in the SORCER environment is also described.
NASA Technical Reports Server (NTRS)
Wintucky, Edwin G.
2002-01-01
A power-efficient, miniature, easily manufactured, reservoir-type barium-dispenser thermionic cathode has been developed that offers the significant advantages of simultaneous high electron-emission current density (>2 A/sq cm) and very long life (>100,000 hr of continuous operation) when compared with the commonly used impregnated-type barium-dispenser cathodes. Important applications of this cathode are a wide variety of microwave and millimeter-wave vacuum electronic devices, where high output power and reliability (long life) are essential. We also expect it to enable the practical development of higher purveyance electron guns for lower voltage and more reliable device operation. The low cathode heater power and reduced size and mass are expected to be particularly beneficial in traveling-wave-tube amplifiers (TWTA's) for space communications, where future NASA mission requirements include smaller onboard spacecraft systems, higher data transmission rates (high frequency and output power) and greater electrical efficiency.
Seo, Tae Hoon; Lee, Seula; Min, Kyung Hyun; Chandramohan, S.; Park, Ah Hyun; Lee, Gun Hee; Park, Min; Suh, Eun-Kyung; Kim, Myung Jong
2016-01-01
This paper reports a highly reliable transparent conductive electrode (TCE) that integrates silver nanowires (AgNWs) and high-quality graphene as a protecting layer. Graphene with minimized defects and large graphene domains has been successfully obtained through a facile two-step growth approach. Ultraviolet light emitting diodes (UV-LEDs) were fabricated with AgNWs or hybrid electrodes where AgNWs were combined with two-step grown graphene (A-2GE) or conventional one-step grown graphene (A-1GE). The device performance and reliability of the UV-LEDs with three different electrodes were compared. The A-2GE offered high figure of merit owing to the excellent UV transmittance and reduced sheet resistance. As a consequence, the UV-LEDs made with A-2GE demonstrated reduced forward voltage, enhanced electroluminescence (EL) intensity, and alleviated efficiency droop. The effects of joule heating and UV light illumination on the electrode stability were also studied. The present findings prove superior performance of the A-2GE under high current injection and continuous operation of UV LED, compared to other electrodes. From our observation, the A-2GE would be a reliable TCE for high power UV-LEDs. PMID:27387274
NASA Astrophysics Data System (ADS)
Seo, Tae Hoon; Lee, Seula; Min, Kyung Hyun; Chandramohan, S.; Park, Ah Hyun; Lee, Gun Hee; Park, Min; Suh, Eun-Kyung; Kim, Myung Jong
2016-07-01
This paper reports a highly reliable transparent conductive electrode (TCE) that integrates silver nanowires (AgNWs) and high-quality graphene as a protecting layer. Graphene with minimized defects and large graphene domains has been successfully obtained through a facile two-step growth approach. Ultraviolet light emitting diodes (UV-LEDs) were fabricated with AgNWs or hybrid electrodes where AgNWs were combined with two-step grown graphene (A-2GE) or conventional one-step grown graphene (A-1GE). The device performance and reliability of the UV-LEDs with three different electrodes were compared. The A-2GE offered high figure of merit owing to the excellent UV transmittance and reduced sheet resistance. As a consequence, the UV-LEDs made with A-2GE demonstrated reduced forward voltage, enhanced electroluminescence (EL) intensity, and alleviated efficiency droop. The effects of joule heating and UV light illumination on the electrode stability were also studied. The present findings prove superior performance of the A-2GE under high current injection and continuous operation of UV LED, compared to other electrodes. From our observation, the A-2GE would be a reliable TCE for high power UV-LEDs.
Automated MRI Cerebellar Size Measurements Using Active Appearance Modeling
Price, Mathew; Cardenas, Valerie A.; Fein, George
2014-01-01
Although the human cerebellum has been increasingly identified as an important hub that shows potential for helping in the diagnosis of a large spectrum of disorders, such as alcoholism, autism, and fetal alcohol spectrum disorder, the high costs associated with manual segmentation, and low availability of reliable automated cerebellar segmentation tools, has resulted in a limited focus on cerebellar measurement in human neuroimaging studies. We present here the CATK (Cerebellar Analysis Toolkit), which is based on the Bayesian framework implemented in FMRIB’s FIRST. This approach involves training Active Appearance Models (AAM) using hand-delineated examples. CATK can currently delineate the cerebellar hemispheres and three vermal groups (lobules I–V, VI–VII, and VIII–X). Linear registration with the low-resolution MNI152 template is used to provide initial alignment, and Point Distribution Models (PDM) are parameterized using stellar sampling. The Bayesian approach models the relationship between shape and texture through computation of conditionals in the training set. Our method varies from the FIRST framework in that initial fitting is driven by 1D intensity profile matching, and the conditional likelihood function is subsequently used to refine fitting. The method was developed using T1-weighted images from 63 subjects that were imaged and manually labeled: 43 subjects were scanned once and were used for training models, and 20 subjects were imaged twice (with manual labeling applied to both runs) and used to assess reliability and validity. Intraclass correlation analysis shows that CATK is highly reliable (average test-retest ICCs of 0.96), and offers excellent agreement with the gold standard (average validity ICC of 0.87 against manual labels). Comparisons against an alternative atlas-based approach, SUIT (Spatially Unbiased Infratentorial Template), that registers images with a high-resolution template of the cerebellum, show that our AAM approach offers superior reliability and validity. Extensions of CATK to cerebellar hemisphere parcels is envisioned. PMID:25192657
A Near-Term, High-Confidence Heavy Lift Launch Vehicle
NASA Technical Reports Server (NTRS)
Rothschild, William J.; Talay, Theodore A.
2009-01-01
The use of well understood, legacy elements of the Space Shuttle system could yield a near-term, high-confidence Heavy Lift Launch Vehicle that offers significant performance, reliability, schedule, risk, cost, and work force transition benefits. A side-mount Shuttle-Derived Vehicle (SDV) concept has been defined that has major improvements over previous Shuttle-C concepts. This SDV is shown to carry crew plus large logistics payloads to the ISS, support an operationally efficient and cost effective program of lunar exploration, and offer the potential to support commercial launch operations. This paper provides the latest data and estimates on the configurations, performance, concept of operations, reliability and safety, development schedule, risks, costs, and work force transition opportunities for this optimized side-mount SDV concept. The results presented in this paper have been based on established models and fully validated analysis tools used by the Space Shuttle Program, and are consistent with similar analysis tools commonly used throughout the aerospace industry. While these results serve as a factual basis for comparisons with other launch system architectures, no such comparisons are presented in this paper. The authors welcome comparisons between this optimized SDV and other Heavy Lift Launch Vehicle concepts.
Silicon Photo-Multiplier Readouts for Scintillators in High-Energy Astronomy
NASA Technical Reports Server (NTRS)
Bloser, Peter F.; Legere, Jason S.; Bancroft, Christopher M.; McConnell, Mark L.; Ryan, James M.
2008-01-01
New scintillator materials have recently been shown to hold great potential for low-cost, reliable gamma-ray detectors in high-energy astronomy. New devices for the detection of scintillation light promise to make scintillator-based instruments even more attractive by reducing mass and power requirements,in particular, silicon photo-multipliers (SiPMs) are starting to become commercially available that offer gains and quantum efficiencies similar to those of photo-multiplier tubes (PMTs), but with greatly reduced mass, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. We have conducted laboratory tests of a sample of commercially available SiPMs coupled to LaBr3;Ce, a scintillator of relevance to to future high-energy astrophysics missions. We present results for gamma-ray spectroscopy. compare the SiPM performance to that of a PMT, and discuss the extent to which SiPMs offer significant advantages for scintillator-based space missions.
Nunes, Andreia; Limpo, Teresa; Lima, César F.; Castro, São Luís
2018-01-01
The importance of quickly assessing personality traits in many studies prompted the development of brief scales such as the Ten-Item Personality Inventory (TIPI), a measure of five personality traits (extraversion, agreeableness, conscientiousness, emotional stability, and openness). In the current study, we present the Portuguese version of TIPI and examine its psychometric properties, based on a sample of 333 Portuguese adults aged 18 to 65 years. The results revealed reliability coefficients similar to the original version (α = 0.39–0.72), very good 4-week test–retest reliability (n = 81, rs > 0.71), expected factorial structure, high convergent validity with the Big-Five Inventory (rs > 0.60), and correlations with self-esteem, affect, and aggressiveness similar to those found with standard measures of personality traits. Overall, our findings suggest that the Portuguese TIPI is a reliable and valid alternative to longer measures: it offers a promising tool for research contexts in which the available time for personality assessment is highly limited. PMID:29674989
Nunes, Andreia; Limpo, Teresa; Lima, César F; Castro, São Luís
2018-01-01
The importance of quickly assessing personality traits in many studies prompted the development of brief scales such as the Ten-Item Personality Inventory (TIPI), a measure of five personality traits (extraversion, agreeableness, conscientiousness, emotional stability, and openness). In the current study, we present the Portuguese version of TIPI and examine its psychometric properties, based on a sample of 333 Portuguese adults aged 18 to 65 years. The results revealed reliability coefficients similar to the original version (α = 0.39-0.72), very good 4-week test-retest reliability ( n = 81, r s > 0.71), expected factorial structure, high convergent validity with the Big-Five Inventory ( r s > 0.60), and correlations with self-esteem, affect, and aggressiveness similar to those found with standard measures of personality traits. Overall, our findings suggest that the Portuguese TIPI is a reliable and valid alternative to longer measures: it offers a promising tool for research contexts in which the available time for personality assessment is highly limited.
Blais, Julie; Forth, Adelle E; Hare, Robert D
2017-06-01
The goal of the current study was to assess the interrater reliability of the Psychopathy Checklist-Revised (PCL-R) among a large sample of trained raters (N = 280). All raters completed PCL-R training at some point between 1989 and 2012 and subsequently provided complete coding for the same 6 practice cases. Overall, 3 major conclusions can be drawn from the results: (a) reliability of individual PCL-R items largely fell below any appropriate standards while the estimates for Total PCL-R scores and factor scores were good (but not excellent); (b) the cases representing individuals with high psychopathy scores showed better reliability than did the cases of individuals in the moderate to low PCL-R score range; and (c) there was a high degree of variability among raters; however, rater specific differences had no consistent effect on scoring the PCL-R. Therefore, despite low reliability estimates for individual items, Total scores and factor scores can be reliably scored among trained raters. We temper these conclusions by noting that scoring standardized videotaped case studies does not allow the rater to interact directly with the offender. Real-world PCL-R assessments typically involve a face-to-face interview and much more extensive collateral information. We offer recommendations for new web-based training procedures. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Immodest Witnesses: Reliability and Writing Assessment
ERIC Educational Resources Information Center
Gallagher, Chris W.
2014-01-01
This article offers a survey of three reliability theories in writing assessment: positivist, hermeneutic, and rhetorical. Drawing on an interdisciplinary investigation of the notion of "witnessing," this survey emphasizes the kinds of readers and readings each theory of reliability produces and the epistemological grounds on which it…
Portfolio Assessment: Increasing Reliability and Validity.
ERIC Educational Resources Information Center
Griffee, Dale
2002-01-01
Addresses the traditional understanding of reliability as it pertains to writing portfolio assessments. Offers a list of practical actions that can be taken to increase assessment reliability, including explicit definitions of what a portfolio holds, rater training, rater burnout, and consistent rating procedures. (Contains 26 references.) (NB)
Sensitive sub-Doppler nonlinear spectroscopy for hyperfine-structure analysis using simple atomizers
NASA Astrophysics Data System (ADS)
Mickadeit, Fritz K.; Kemp, Helen; Schafer, Julia; Tong, William M.
1998-05-01
Laser wave-mixing spectroscopy is presented as a sub-Doppler method that offers not only high spectral resolution, but also excellent detection sensitivity. It offers spectral resolution suitable for hyperfine structure analysis and isotope ratio measurements. In a non-planar backward- scattering four-wave mixing optical configuration, two of the three input beams counter propagate and the Doppler broadening is minimized, and hence, spectral resolution is enhanced. Since the signal is a coherent beam, optical collection is efficient and signal detection is convenient. This simple multi-photon nonlinear laser method offers un usually sensitive detection limits that are suitable for trace-concentration isotope analysis using a few different types of simple analytical atomizers. Reliable measurement of hyperfine structures allows effective determination of isotope ratios for chemical analysis.
Advanced energy system program
NASA Astrophysics Data System (ADS)
Trester, K.
1989-02-01
The objectives of the program are to design, develop and demonstrate a natural-gas-fueled, highly recuperated, 50 kW Brayton-cycle cogeneration system for commercial, institutional, and multifamily residential applications. Marketing studies have shown that this Advanced Energy System (AES), with its many unique and cost-effective features, has the potential to offer significant reductions in annual electrical and thermal energy costs to the consumer. Specific advantages of the system that result in low cost of ownership are high electrical efficiency (30 percent, HHV), low maintenance, high reliability and long life (20 years).
Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies
Uhlemann, Elisabeth
2018-01-01
Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC) method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications. PMID:29570676
Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies.
Balador, Ali; Uhlemann, Elisabeth; Calafate, Carlos T; Cano, Juan-Carlos
2018-03-23
Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC) method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications.
Bandwidth efficient coding for satellite communications
NASA Technical Reports Server (NTRS)
Lin, Shu; Costello, Daniel J., Jr.; Miller, Warner H.; Morakis, James C.; Poland, William B., Jr.
1992-01-01
An error control coding scheme was devised to achieve large coding gain and high reliability by using coded modulation with reduced decoding complexity. To achieve a 3 to 5 dB coding gain and moderate reliability, the decoding complexity is quite modest. In fact, to achieve a 3 dB coding gain, the decoding complexity is quite simple, no matter whether trellis coded modulation or block coded modulation is used. However, to achieve coding gains exceeding 5 dB, the decoding complexity increases drastically, and the implementation of the decoder becomes very expensive and unpractical. The use is proposed of coded modulation in conjunction with concatenated (or cascaded) coding. A good short bandwidth efficient modulation code is used as the inner code and relatively powerful Reed-Solomon code is used as the outer code. With properly chosen inner and outer codes, a concatenated coded modulation scheme not only can achieve large coding gains and high reliability with good bandwidth efficiency but also can be practically implemented. This combination of coded modulation and concatenated coding really offers a way of achieving the best of three worlds, reliability and coding gain, bandwidth efficiency, and decoding complexity.
A Comparison of Two Methods of Determining Interrater Reliability
ERIC Educational Resources Information Center
Fleming, Judith A.; Taylor, Janeen McCracken; Carran, Deborah
2004-01-01
This article offers an alternative methodology for practitioners and researchers to use in establishing interrater reliability for testing purposes. The majority of studies on interrater reliability use a traditional methodology where by two raters are compared using a Pearson product-moment correlation. This traditional method of estimating…
Frequency doubled high-power disk lasers in pulsed and continuous-wave operation
NASA Astrophysics Data System (ADS)
Weiler, Sascha; Hangst, Alexander; Stolzenburg, Christian; Zawischa, Ivo; Sutter, Dirk; Killi, Alexander; Kalfhues, Steffen; Kriegshaeuser, Uwe; Holzer, Marco; Havrilla, David
2012-03-01
The disk laser with multi-kW output power in infrared cw operation is widely used in today's manufacturing, primarily in the automotive industry. The disk technology combines high power (average and/or peak power), excellent beam quality, high efficiency and high reliability with low investment and operating costs. Additionally, the disk laser is ideally suited for frequency conversion due to its polarized output with negligible depolarization losses. Laser light in the green spectral range (~515 nm) can be created with a nonlinear crystal. Pulsed disk lasers with green output of well above 50 W (extracavity doubling) in the ps regime and several hundreds of Watts in the ns regime with intracavity doubling are already commercially available whereas intracavity doubled disk lasers in continuous wave operation with greater than 250 W output are in test phase. In both operating modes (pulsed and cw) the frequency doubled disk laser offers advantages in existing and new applications. Copper welding for example is said to show much higher process reliability with green laser light due to its higher absorption in comparison to the infrared. This improvement has the potential to be very beneficial for the automotive industry's move to electrical vehicles which requires reliable high-volume welding of copper as a major task for electro motors, batteries, etc.
Reliability of temporal summation and diffuse noxious inhibitory control
Cathcart, Stuart; Winefield, Anthony H; Rolan, Paul; Lushington, Kurt
2009-01-01
BACKGROUND: The test-retest reliability of temporal summation (TS) and diffuse noxious inhibitory control (DNIC) has not been reported to date. Establishing such reliability would support the possibility of future experimental studies examining factors affecting TS and DNIC. Similarly, the use of manual algometry to induce TS, or an occlusion cuff to induce DNIC of TS to mechanical stimuli, has not been reported to date. Such devices may offer a simpler method than current techniques for inducing TS and DNIC, affording assessment at more anatomical locations and in more varied research settings. METHOD: The present study assessed the test-retest reliability of TS and DNIC using the above techniques. Sex differences on these measures were also investigated. RESULTS: Repeated measures ANOVA indicated successful induction of TS and DNIC, with no significant differences across test-retest occasions. Sex effects were not significant for any measure or interaction. Intraclass correlations indicated high test-retest reliability for all measures; however, there was large interindividual variation between test and retest measurements. CONCLUSION: The present results indicate acceptable within-session test-retest reliability of TS and DNIC. The results support the possibility of future experimental studies examining factors affecting TS and DNIC. PMID:20011713
Power Hardware-in-the-Loop (PHIL) Testing Facility for Distributed Energy Storage (Poster)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neubauer.J.; Lundstrom, B.; Simpson, M.
2014-06-01
The growing deployment of distributed, variable generation and evolving end-user load profiles presents a unique set of challenges to grid operators responsible for providing reliable and high quality electrical service. Mass deployment of distributed energy storage systems (DESS) has the potential to solve many of the associated integration issues while offering reliability and energy security benefits other solutions cannot. However, tools to develop, optimize, and validate DESS control strategies and hardware are in short supply. To fill this gap, NREL has constructed a power hardware-in-the-loop (PHIL) test facility that connects DESS, grid simulator, and load bank hardware to a distributionmore » feeder simulation.« less
NASA Astrophysics Data System (ADS)
Qiang, Tian; Wang, Cong; Kim, Nam-Young
2017-08-01
A diplexer offering the advantages of compact size, high performance, and high reliability is proposed on the basis of advanced integrated passive device (IPD) fabrication techniques. The proposed diplexer is developed by combining a third-order low-pass filter (LPF) and a third-order high-pass filter (HPF), which are designed on the basis of the elliptic function prototype low-pass filter. Primary components, such as inductors and capacitors, are designed and fabricated with high Q-factor and appropriate values, and they are subsequently used to construct a compact diplexer having a chip area of 900 μm × 1100 μm (0.009 λ0 × 0.011 λ0, where λ0 is the guided wavelength). In addition, a small-outline transistor (SOT-6) packaging method is adopted, and reliability tests (including temperature, humidity, vibration, and pressure) are conducted to guarantee long-term stability and commercial success. The packaged measurement results indicate excellent RF performance with insertion losses of 1.39 dB and 0.75 dB at operation bands of 0.9 GHz and 1.8 GHz, respectively. The return loss is lower than 10 dB from 0.5 GHz to 4.0 GHz, while the isolation is higher than 15 dB from 0.5 GHz to 3.0 GHz. Thus, it can be concluded that the proposed SOT-6 packaged diplexer is a promising candidate for GSM/CDMA applications. Synthetic solution of diplexer design, RF performance optimization, fabrication process, packaging, RF response measurement, and reliability test is particularly explained and analyzed in this work.
Sorsdahl, Anne Brit; Moe-Nilssen, Rolf; Strand, Liv Inger
2008-02-01
The aim of this study was to examine observer reliability of the Gross Motor Performance Measure (GMPM) and the Quality of Upper Extremity Skills Test (QUEST) based on video clips. The tests were administered to 26 children with cerebral palsy (CP; 14 males, 12 females; range 2-13y, mean 7y 6mo), 24 with spastic CP, and two with dyskinesia. Respectively, five, six, five, four, and six children were classified in Gross Motor Function Classification System Levels I to V; and four, nine, five, five, and three children were classified in Manual Ability Classification System levels I to V. The children's performances were recorded and edited. Two experienced paediatric physical therapists assessed the children from watching the video clips. Intraobserver and interobserver reliability values of the total scores were mostly high, intraclass correlation coefficient (ICC)(1,1) varying from 0.69 to 0.97 with only one coefficient below 0.89. The ICCs of subscores varied from 0.36 to 0.95, finding'Alignment'and'Weight shift'in GMPM and'Protective extension'in QUEST highly reliable. The subscores'Dissociated movements'in GMPM and QUEST, and'Grasp'in QUEST were the least reliable, and recommendations are made to increase reliability of these subscores. Video scoring was time consuming, but was found to offer many advantages; the possibility to review performance, to use special trained observers for scoring and less demanding assessment for the children.
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander; Sahu, Kusum
2003-01-01
Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.
Jiang, Liren
2017-01-01
Background The aim was to develop scalable Whole Slide Imaging (sWSI), a WSI system based on mainstream smartphones coupled with regular optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry objective lenses of different magnifications, and reasonably high throughput. These performance metrics should be evaluated by expert pathologists and match those of high-end scanners. Objective The aim was to develop scalable Whole Slide Imaging (sWSI), a whole slide imaging system based on smartphones coupled with optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry object lens of different magnification. All performance metrics should be evaluated by expert pathologists and match those of high-end scanners. Methods In the sWSI design, the digitization process is split asynchronously between light-weight clients on smartphones and powerful cloud servers. The client apps automatically capture FoVs at up to 12-megapixel resolution and process them in real-time to track the operation of users, then give instant feedback of guidance. The servers first restitch each pair of FoVs, then automatically correct the unknown nonlinear distortion introduced by the lens of the smartphone on the fly, based on pair-wise stitching, before finally combining all FoVs into one gigapixel VS for each scan. These VSs can be viewed using Internet browsers anywhere. In the evaluation experiment, 100 frozen section slides from patients randomly selected among in-patients of the participating hospital were scanned by both a high-end Leica scanner and sWSI. All VSs were examined by senior pathologists whose diagnoses were compared against those made using optical microscopy as ground truth to evaluate the image quality. Results The sWSI system is developed for both Android and iPhone smartphones and is currently being offered to the public. The image quality is reliable and throughput is approximately 1 FoV per second, yielding a 15-by-15 mm slide under 20X object lens in approximately 30-35 minutes, with little training required for the operator. The expected cost for setup is approximately US $100 and scanning each slide costs between US $1 and $10, making sWSI highly cost-effective for infrequent or low-throughput usage. In the clinical evaluation of sample-wise diagnostic reliability, average accuracy scores achieved by sWSI-scan-based diagnoses were as follows: 0.78 for breast, 0.88 for uterine corpus, 0.68 for thyroid, and 0.50 for lung samples. The respective low-sensitivity rates were 0.05, 0.05, 0.13, and 0.25 while the respective low-specificity rates were 0.18, 0.08, 0.20, and 0.25. The participating pathologists agreed that the overall quality of sWSI was generally on par with that produced by high-end scanners, and did not affect diagnosis in most cases. Pathologists confirmed that sWSI is reliable enough for standard diagnoses of most tissue categories, while it can be used for quick screening of difficult cases. Conclusions As an ultra-low-cost alternative to whole slide scanners, diagnosis-ready VS quality and robustness for commercial usage is achieved in the sWSI solution. Operated on main-stream smartphones installed on normal optical microscopes, sWSI readily offers affordable and reliable WSI to resource-limited or infrequent clinical users. PMID:28916508
16,000-rpm Interior Permanent Magnet Reluctance Machine with Brushless Field Excitation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, John S; Burress, Timothy A; Lee, Seong T
2008-01-01
This paper introduces a high speed brushless field excitation (BFE) machine that offers high torque per ampere (A) per core length at low speed and weakened flux at high speed. Lower core losses at high speeds, are attained by reducing the field excitation. Safety and reliability are increased by weakening the field when a winding short-circuit fault occurs. For a high-speed motor the bridges that link the rotor punching segments together must be thickened for mechanical integrity; BFE can ensure sufficient rotor flux when needed. Projected efficiency map including losses of the excitation coils confirms the advantage of this technology.
Thermodynamic Improvements for the Space Thermoacoustic Refrigerator (STAR)
1988-06-01
Sondhauss proved that the vibration of the glass itself did not generate the sound, but he offered no explanation as to what did. In his description...noise of aeroengines above that predicted by theory. He determined that the sound was produced by unsteady heat transfer. Each of these latter three...lifetimes (expendable cryogens) and high vibration levels and low reliability (closed cycle refrigerators). The advantages of the thermoacoustic
NASA Puffin Electric Tailsitter VTOL Concept
NASA Technical Reports Server (NTRS)
Moore, Mark D.
2010-01-01
Electric propulsion offers dramatic new vehicle mission capabilities, not possible with turbine or reciprocating engines; including high reliability and efficiency, low engine weight and maintenance, low cooling drag and volume required, very low noise and vibration, and zero emissions. The only penalizing characteristic of electric propulsion is the current energy storage technology level, which is set to triple over the next 5-10 years through huge new investments in this field. Most importantly, electric propulsion offers incredible new degrees of freedom in aircraft system integration to achieve unprecedented levels of aerodynamic, propulsive, control, and structural synergistic coupling. A unique characteristic of electric propulsion is that the technology is nearly scale-free, permitting small motors to be parallelized for fail-safe redundancy, or distributed across the airframe for tightly coupled interdisciplinary functionality without significant impacts in motor-controller efficiency or specific weight. Maximizing the potential benefit of electric propulsion is dependent on applying this technology to synergistic mission concepts. The vehicle missions with the most benefit include those which constrain environmental impact (or limit noise, exhaust, or emission signatures) are short range, or where large differences exist in the propulsion system sizing between takeoff and cruise conditions. Electric propulsion offers the following unique capabilities that other propulsion systems can t provide for short range Vertical Takeoff and Landing (VTOL) aircraft; elimination of engine noise and emissions, drastic reduction in engine cooling and radiated heat, drastic reduction in vehicle vibration levels, drastic improvement in reliability and operating costs, variable speed output at full power, for improved cruise efficiency at low tip-speed, elimination of high/hot sizing penalty, and reduction of engine-out penalties.
Radioisotope Power System Pool Concept
NASA Technical Reports Server (NTRS)
Rusick, Jeffrey J.; Bolotin, Gary S.
2015-01-01
Advanced Radioisotope Power Systems (RPS) for NASA deep space science missions have historically used static thermoelectric-based designs because they are highly reliable, and their radioisotope heat sources can be passively cooled throughout the mission life cycle. Recently, a significant effort to develop a dynamic RPS, the Advanced Stirling Radioisotope Generator (ASRG), was conducted by NASA and the Department of Energy, because Stirling based designs offer energy conversion efficiencies four times higher than heritage thermoelectric designs; and the efficiency would proportionately reduce the amount of radioisotope fuel needed for the same power output. However, the long term reliability of a Stirling based design is a concern compared to thermoelectric designs, because for certain Stirling system architectures the radioisotope heat sources must be actively cooled via the dynamic operation of Stirling converters throughout the mission life cycle. To address this reliability concern, a new dynamic Stirling cycle RPS architecture is proposed called the RPS Pool Concept.
Reliability and validity of the Modified Erikson Psychosocial Stage Inventory in diverse samples.
Leidy, N K; Darling-Fisher, C S
1995-04-01
The Modified Erikson Psychosocial Stage Inventory (MEPSI) is a relatively simple survey measure designed to assess the strength of psychosocial attributes that arise from progression through Erikson's eight stages of development. The purpose of this study was to employ secondary analysis to evaluate the internal-consistency reliability and construct validity of the MEPSI across four diverse samples: healthy young adults, hemophilic men, healthy older adults, and older adults with chronic obstructive pulmonary disease. Special attention was given to the performance of the measure across gender, with exploratory analyses examining possible age cohort and health status effects. Internal-consistency estimates for the aggregate measure were high, whereas subscale reliability levels varied across age groups. Construct validity was supported across samples. Gender, cohort, and health effects offered interesting psychometric and theoretical insights and direction for further research. Findings indicated that the MEPSI might be a useful instrument for operationalizing and testing Eriksonian developmental theory in adults.
Tork, Hanan; Lohrmann, Christa; Dassen, Theo
2008-03-01
The objectives of this study were to examine the psychometric properties of the modified Care Dependency Scale in a pediatric setting and to explore the extent of dependency of school-aged children regarding their self-care. The data were collected from 130 hospitalized children, aged 6-12 years. The reliability was determined by Cronbach's alpha, which showed a high level of consistency. The subsequent inter-rater reliability revealed moderate-to-substantial agreement. The criterion-related validity was tested by comparing the sum scores of the Care Dependency Scale for Paediatrics and the Visual Analog Scale. Factor analysis was used to investigate the construct validity and resulted in a one-factor solution. In conclusion, this study provides evidence that the Care Dependency Scale for Paediatrics is a valid and reliable measure that offers a comprehensive assessment from a nursing perspective and enables nurses to help children acquire independence.
A low-cost, high-field-strength magnetic resonance imaging-compatible actuator.
Secoli, Riccardo; Robinson, Matthew; Brugnoli, Michele; Rodriguez y Baena, Ferdinando
2015-03-01
To perform minimally invasive surgical interventions with the aid of robotic systems within a magnetic resonance imaging scanner offers significant advantages compared to conventional surgery. However, despite the numerous exciting potential applications of this technology, the introduction of magnetic resonance imaging-compatible robotics has been hampered by safety, reliability and cost concerns: the robots should not be attracted by the strong magnetic field of the scanner and should operate reliably in the field without causing distortion to the scan data. Development of non-conventional sensors and/or actuators is thus required to meet these strict operational and safety requirements. These demands commonly result in expensive actuators, which mean that cost effectiveness remains a major challenge for such robotic systems. This work presents a low-cost, high-field-strength magnetic resonance imaging-compatible actuator: a pneumatic stepper motor which is controllable in open loop or closed loop, along with a rotary encoder, both fully manufactured in plastic, which are shown to perform reliably via a set of in vitro trials while generating negligible artifacts when imaged within a standard clinical scanner. © IMechE 2015.
Exploring Differences in Measurement and Reporting of Classroom Observation Inter-Rater Reliability
ERIC Educational Resources Information Center
Wilhelm, Anne Garrison; Gillespie Rouse, Amy; Jones, Francesca
2018-01-01
Although inter-rater reliability is an important aspect of using observational instruments, it has received little theoretical attention. In this article, we offer some guidance for practitioners and consumers of classroom observations so that they can make decisions about inter-rater reliability, both for study design and in the reporting of data…
Atci, Ibrahim Burak; Yilmaz, Hakan; Kocaman, Umit; Samanci, Mustafa Yavuz
2017-07-01
The aim of this study was to evaluate the Internet use of a group of lumbar disc surgery candidates in order to determine the rate of Internet search by the patients on their disorders and more importantly the reliability of the accessed websites. Fifty patients who were scheduled for lumbar disc surgery were divided into 2 groups, namely patients who accepted the surgery at the first offer and those who wanted to think over. Educational level information was obtained and patients were asked whether they had searched their disorder and offered surgery on the Internet. Then, a questionnaire was administered and the reliability of the websites was evaluated. Correction: The first 30 websites on the first 3 pages of Google ® search engine, the most commonly used search engine in Turkey, were evaluated with the DISCERN ® instrument. Of 50 patients, 33 (66%) had conducted a search for the surgery on the Internet. All university graduates, 88.2% of high school graduates, and 18.7% of primary-secondary school graduates had conducted an Internet search. The quality and reliability of the information was high (4.5 points) for 2 (7.1%) websites, moderate (2.3 points) for 6 websites (21.4%) and poor (1 point) for 20 websites (71.4%) as scored with the DISCERN ® instrument. The mean DISCERN ® score of was 1.1 for websites of health-related institutions or healthcare news, 2.75 for personal websites of physicians and 2.5 for personal websites of non-physicians. The mean DISCERN ® score of all websites was 1.5. Most of the patients undergoing lumbar disc surgery at our clinic had searched information about the surgical procedure on the Internet. We found that 92.9% of the websites evaluated with the DISCERN ® instrument had inadequate information, suggesting low-level reliability. Copyright © 2017 Elsevier B.V. All rights reserved.
The state-of-the-art of dc power distribution systems/components for space applications
NASA Technical Reports Server (NTRS)
Krauthamer, S.
1988-01-01
This report is a survey of the state of the art of high voltage dc systems and components. This information can be used for consideration of an alternative secondary distribution (120 Vdc) system for the Space Station. All HVdc components have been prototyped or developed for terrestrial, aircraft, and spacecraft applications, and are applicable for general space application with appropriate modification and qualification. HVdc systems offer a safe, reliable, low mass, high efficiency and low EMI alternative for Space Station secondary distribution.
Flat conductor cable for electrical packaging
NASA Technical Reports Server (NTRS)
Angele, W.
1972-01-01
Flat conductor cable (FCC) is relatively new, highly promising means for electrical packaging and system integration. FCC offers numerous desirable traits (weight, volume and cost savings, flexibility, high reliability, predictable and repeatable electrical characteristics) which make it extremely attractive as a packaging medium. FCC, today, finds wide application in everything from integration of lunar equipment to the packaging of electronics in nuclear submarines. Described are cable construction and means of termination, applicable specifications and standards, and total FCC systems. A list of additional sources of data is also included for more intensive study.
NASA Astrophysics Data System (ADS)
Ye, L.; Wu, B.
2017-09-01
High-resolution imagery is an attractive option for surveying and mapping applications due to the advantages of high quality imaging, short revisit time, and lower cost. Automated reliable and dense image matching is essential for photogrammetric 3D data derivation. Such matching, in urban areas, however, is extremely difficult, owing to the complexity of urban textures and severe occlusion problems on the images caused by tall buildings. Aimed at exploiting high-resolution imagery for 3D urban modelling applications, this paper presents an integrated image matching and segmentation approach for reliable dense matching of high-resolution imagery in urban areas. The approach is based on the framework of our existing self-adaptive triangulation constrained image matching (SATM), but incorporates three novel aspects to tackle the image matching difficulties in urban areas: 1) occlusion filtering based on image segmentation, 2) segment-adaptive similarity correlation to reduce the similarity ambiguity, 3) improved dense matching propagation to provide more reliable matches in urban areas. Experimental analyses were conducted using aerial images of Vaihingen, Germany and high-resolution satellite images in Hong Kong. The photogrammetric point clouds were generated, from which digital surface models (DSMs) were derived. They were compared with the corresponding airborne laser scanning data and the DSMs generated from the Semi-Global matching (SGM) method. The experimental results show that the proposed approach is able to produce dense and reliable matches comparable to SGM in flat areas, while for densely built-up areas, the proposed method performs better than SGM. The proposed method offers an alternative solution for 3D surface reconstruction in urban areas.
Texas nutrition environment assessment of retail food stores (TxNEA-S): development and evaluation.
Gloria, Christian T; Steinhardt, Mary A
2010-11-01
Current nutrition environment instruments are typically designed to measure a small number of healthy foods based on national trends. They lack the depth to accurately measure the unique dietary choices of subpopulations, such as Texas consumers whose food preferences are influenced by Hispanic/Latino culture. Thus the purposes of the present study were to: (i) develop a comprehensive observational tool to measure the availability of healthy foods from retail stores in Texas; and (ii) conduct a pilot test to examine the tool's reliability, as well as differences in the availability of healthy foods in stores between high- and low-income neighbourhoods. Grocery and convenience stores were assessed for availability of healthy foods. Reliability was calculated using percentage agreement, and differences in availability were examined using 2 (store type) × 2 (neighbourhood income) ANOVA. One high-income and one low-income neighbourhood in Austin, Texas. A sample of thirty-eight stores comprising twenty-five convenience stores and thirteen grocery stores. The low-income neighbourhood had 324 % more convenience stores and 56 % fewer grocery stores than the high-income neighbourhood. High inter-rater (mean = 0·95) and test-retest reliability (mean = 0·92) and a significant interaction (P = 0·028) between store type and neighbourhood income were found. The TxNEA-S tool includes 106 healthy food items, such as fruits, vegetables, dairy, proteins and grains. The tool is reliable and face validity is affirmed by the Texas Department of Health. Grocery stores have more healthy foods than convenience stores, and high-income grocery stores offer more healthy foods than low-income grocery stores.
Advanced Rankine and Brayton cycle power systems - Materials needs and opportunities
NASA Technical Reports Server (NTRS)
Grisaffe, S. J.; Guentert, D. C.
1974-01-01
Conceptual advanced potassium Rankine and closed Brayton power conversion cycles offer the potential for improved efficiency over steam systems through higher operating temperatures. However, for utility service of at least 100,000 hours, materials technology advances will be needed for such high temperature systems. Improved alloys and surface protection must be developed and demonstrated to resist coal combustion gases as well as potassium corrosion or helium surface degradation at high temperatures. Extensions in fabrication technology are necessary to produce large components of high temperature alloys. Long-time property data must be obtained under environments of interest to assure high component reliability.
Advanced Rankine and Brayton cycle power systems: Materials needs and opportunities
NASA Technical Reports Server (NTRS)
Grisaffe, S. J.; Guentert, D. C.
1974-01-01
Conceptual advanced potassium Rankine and closed Brayton power conversion cycles offer the potential for improved efficiency over steam systems through higher operating temperatures. However, for utility service of at least 100,000 hours, materials technology advances will be needed for such high temperature systems. Improved alloys and surface protection must be developed and demonstrated to resist coal combustion gases as well as potassium corrosion or helium surface degradation at high temperatures. Extensions in fabrication technology are necessary to produce large components of high temperature alloys. Long time property data must be obtained under environments of interest to assure high component reliability.
The psychosocial inventory of ego strengths: examination of theory and psychometric properties.
Markstrom, Carol A; Marshall, Sheila K
2007-02-01
The psychosocial inventory of ego strengths (PIES) was devised as a measure of Erikson's eight ego strengths. The present investigation extended previous research through examination of the validity and reliability of the PIES among 502 high school students. The study also included an appraisal of Erikson's ego strengths as indices of psychosocial well-being. Reliability of the subscales of the PIES was shown through acceptable Cronbach's alphas. As expected, higher scores on ego strengths were positively correlated with psychosocial indictors of identity achievement, self-esteem, locus of control, empathic concern, perspective-taking, and positive forms of coping. Lower scores on ego strengths were related to less desirable psychosocial constructs. Biological sex and age differences also are reported. Based on the findings, the study offers validation of psychosocial theory. As well, the PIES is recommended for use among high school students.
Non-Invasive Tension Measurement Devices for Parachute Cordage
NASA Technical Reports Server (NTRS)
Litteken, Douglas A.; Daum, Jared S.
2016-01-01
The need for lightweight and non-intrusive tension measurements has arisen alongside the development of high-fidelity computer models of textile and fluid dynamics. In order to validate these computer models, data must be gathered in the operational environment without altering the design, construction, or performance of the test article. Current measurement device designs rely on severing a cord and breaking the load path to introduce a load cell. These load cells are very reliable, but introduce an area of high stiffness in the load path, directly affecting the structural response, adding excessive weight, and possibly altering the dynamics of the parachute during a test. To capture the required data for analysis validation without affecting the response of the system, non-invasive measurement devices have been developed and tested by NASA. These tension measurement devices offer minimal impact to the mass, form, fit, and function of the test article, while providing reliable, axial tension measurements for parachute cordage.
Strus, Mark C; Chiaramonti, Ann N; Kim, Young Lae; Jung, Yung Joon; Keller, Robert R
2011-07-01
We investigate the electrical reliability of nanoscale lines of highly aligned, networked, metallic/semiconducting single-walled carbon nanotubes (SWCNTs) fabricated through a template-based fluidic assembly process. We find that these SWCNT networks can withstand DC current densities larger than 10 MA cm(-2) for several hours and, in some cases, several days. We develop test methods that show that the degradation rate, failure predictability and total device lifetime can be linked to the initial resistance. Scanning electron and transmission electron microscopy suggest that fabrication variability plays a critical role in the rate of degradation, and we offer an empirical method of quickly determining the long-term performance of a network. We find that well-fabricated lines subject to constant electrical stress show a linear accumulation of damage reminiscent of electromigration in metallic interconnects, and we explore the underlying physical mechanisms that could cause such behavior.
NASA Astrophysics Data System (ADS)
Chiuchiolo, A.; Bajko, M.; Perez, J. C.; Bajas, H.; Consales, M.; Giordano, M.; Breglio, G.; Palmieri, L.; Cusano, A.
2014-08-01
The design, fabrication and tests of a new generation of superconducting magnets for the upgrade of the LHC require the support of an adequate, robust and reliable sensing technology. The use of Fiber Optic Sensors is becoming particularly challenging for applications in extreme harsh environments such as ultra-low temperatures, high electromagnetic fields and strong mechanical stresses offering perspectives for the development of technological innovations in several applied disciplines.
Modular Wireless Data-Acquisition and Control System
NASA Technical Reports Server (NTRS)
Perotti, Jose; Lucena, Angel; Medelius, Pedro; Mata, Carlos; Eckhoff, Anthony; Blalock, Norman
2004-01-01
A modular wireless data-acquisition and control system, now in operation at Kennedy Space Center, offers high performance at relatively low cost. The system includes a central station and a finite number of remote stations that communicate with each other through low-power radio frequency (RF) links. Designed to satisfy stringent requirements for reliability, integrity of data, and low power consumption, this system could be reproduced and adapted to use in a broad range of settings.
Advanced composites for windmills
NASA Astrophysics Data System (ADS)
Bourquardez, G.
A development status assessment is conducted for advanced composite construction techniques for windmill blade structures which, as in the case of composite helicopter rotors, promise greater reliability, longer service life, superior performance, and lower costs. Composites in wind turbine applications must bear aerodynamic, inertial and gravitational loads in complex interaction cycles. Attention is given to large Darrieus-type vertical axis windmills, to which composite construction methods may offer highly effective pitch-control mechanisms, especially in the 'umbrella' configuration.
NASA Astrophysics Data System (ADS)
Fan, Xiao-Ning; Zhi, Bo
2017-07-01
Uncertainties in parameters such as materials, loading, and geometry are inevitable in designing metallic structures for cranes. When considering these uncertainty factors, reliability-based design optimization (RBDO) offers a more reasonable design approach. However, existing RBDO methods for crane metallic structures are prone to low convergence speed and high computational cost. A unilevel RBDO method, combining a discrete imperialist competitive algorithm with an inverse reliability strategy based on the performance measure approach, is developed. Application of the imperialist competitive algorithm at the optimization level significantly improves the convergence speed of this RBDO method. At the reliability analysis level, the inverse reliability strategy is used to determine the feasibility of each probabilistic constraint at each design point by calculating its α-percentile performance, thereby avoiding convergence failure, calculation error, and disproportionate computational effort encountered using conventional moment and simulation methods. Application of the RBDO method to an actual crane structure shows that the developed RBDO realizes a design with the best tradeoff between economy and safety together with about one-third of the convergence speed and the computational cost of the existing method. This paper provides a scientific and effective design approach for the design of metallic structures of cranes.
NASA Technical Reports Server (NTRS)
Kiser, James D.; Levine, Stanley R.; Dicarlo, James A.
1987-01-01
Structural ceramics were under nearly continuous development for various heat engine applications since the early 1970s. These efforts were sustained by the properties that ceramics offer in the areas of high-temperature strength, environmental resistance, and low density and the large benefits in system efficiency and performance that can result. The promise of ceramics was not realized because their brittle nature results in high sensitivity to microscopic flaws and catastrophic fracture behavior. This translated into low reliability for ceramic components and thus limited their application in engines. For structural ceramics to successfully make inroads into the terrestrial heat engine market requires further advances in low cost, net shape fabrication of high reliability components, and improvements in properties such as toughness, and strength. These advances will lead to very limited use of ceramics in noncritical applications in aerospace engines. For critical aerospace applications, an additional requirement is that the components display markedly improved toughness and noncatastrophic or graceful fracture. Thus the major emphasis is on fiber-reinforced ceramics.
Next generation diode lasers with enhanced brightness
NASA Astrophysics Data System (ADS)
Ried, S.; Rauch, S.; Irmler, L.; Rikels, J.; Killi, A.; Papastathopoulos, E.; Sarailou, E.; Zimer, H.
2018-02-01
High-power diode lasers are nowadays well established manufacturing tools in high power materials processing, mainly for tactile welding, surface treatment and cladding applications. Typical beam parameter products (BPP) of such lasers range from 30 to 50 mm·mrad at several kilowatts of output power. TRUMPF offers a product line of diode lasers to its customers ranging from 150 W up to 6 kW of output power. These diode lasers combine high reliability with small footprint and high efficiency. However, up to now these lasers are limited in brightness due to the commonly used spatial and coarse spectral beam combining techniques. Recently diode lasers with enhanced brightness have been presented by use of dense wavelength multiplexing (DWM). In this paper we report on TRUMPF's diode lasers utilizing DWM. We demonstrate a 2 kW and a 4 kW system ideally suited for fine welding and scanner welding applications. The typical laser efficiency is in the range of 50%. The system offers plug and play exchange of the fiber beam delivery cable, multiple optical outputs and integrated cooling in a very compact package. An advanced control system offers flexible integration in any customer's shop floor environment and includes industry 4.0 capabilities (e.g. condition monitoring and predictive maintenance).
Predicting Cost/Reliability/Maintainability of Advanced General Aviation Avionics Equipment
NASA Technical Reports Server (NTRS)
Davis, M. R.; Kamins, M.; Mooz, W. E.
1978-01-01
A methodology is provided for assisting NASA in estimating the cost, reliability, and maintenance (CRM) requirements for general avionics equipment operating in the 1980's. Practical problems of predicting these factors are examined. The usefulness and short comings of different approaches for modeling coast and reliability estimates are discussed together with special problems caused by the lack of historical data on the cost of maintaining general aviation avionics. Suggestions are offered on how NASA might proceed in assessing cost reliability CRM implications in the absence of reliable generalized predictive models.
Multiple objective optimization in reliability demonstration test
Lu, Lu; Anderson-Cook, Christine Michaela; Li, Mingyang
2016-10-01
Reliability demonstration tests are usually performed in product design or validation processes to demonstrate whether a product meets specified requirements on reliability. For binomial demonstration tests, the zero-failure test has been most commonly used due to its simplicity and use of minimum sample size to achieve an acceptable consumer’s risk level. However, this test can often result in unacceptably high risk for producers as well as a low probability of passing the test even when the product has good reliability. This paper explicitly explores the interrelationship between multiple objectives that are commonly of interest when planning a demonstration test andmore » proposes structured decision-making procedures using a Pareto front approach for selecting an optimal test plan based on simultaneously balancing multiple criteria. Different strategies are suggested for scenarios with different user priorities and graphical tools are developed to help quantify the trade-offs between choices and to facilitate informed decision making. As a result, potential impacts of some subjective user inputs on the final decision are studied to offer insights and useful guidance for general applications.« less
Deep anisotropic ICP plasma etching designed for high-volume MEMS manufacturing
NASA Astrophysics Data System (ADS)
Yu, Keven; Feldbaum, Michael; Pandhumsoporn, Tam; Gadgil, Prashant
1999-08-01
ICP plasma etching is gaining widespread acceptance as an enabling micromachining technology for advanced MEMS fabrication. Whereas this technology has shown a capability of delivering multiple novel applications for R and D, its acceptance by industry for high volume production has been limited. This acceptance into production will only occur when the plasma etching equipment with this technology offers the device performance, throughput, reliability, and uptime criteria required by a production facility. The design of the plasma etcher using this technology and the process capability it consequently delivers, has significant implications in making this a reality. Alcatel has been supplying such a technology to this MEMS industry for over 5 years and in the interim has evolved its product and process to make this technology production worthy. Alcatel's next generation etcher, the Alcatel 601E, offers multiple advantages to MEMS manufacturers in realizing their production goals.
Graziottin, A
2014-10-01
The contraceptive pill containing estradiol valerate and dienogest meets women's requests for: a more natural contraceptive, that is reliable and easy to use, with positive cosmetic effects; less intense and shorter bleeding, reduced anaemia and increased vital energy; reduced dysmenorrhoea and all the specific cycle-related symptoms linked to a drop in oestrogen and the related systemic inflammation, the result of a hormone free interval (HFI) of just two days; with a good impact on sexuality and overall well-being, all associated with a high level of efficacy: (uncorrected Pearl Index: 0.79; corrected: 0.42). Women would prefer more natural hormonal contraception, with high reliability, good tolerability, a simple dosing schedule and possibly some health advantages. To evaluate what the pill containing estradiol valerate and dienogest can offer women and the best way to communicate this opportunity, after 4 years of growing clinical use. A review of literature plus the Author's clinical experience. The new pill containing estradiol valerate and dienogest may satisfy women's need for: a more natural hormonal contraceptive with a low hormone dosage, high reliability and good tolerability; a simple dosing schedule (one pill per day for 28 days); a positive cosmetic effect on the skin; lighter and shorter withdrawal bleeding, improved anaemia, less fatigue and higher vital energy; reduced dysmenorrhoea and a dramatic reduction in all symptoms thanks to a shorter Hormone Free Interval (HFI) of just two days. The new pill is an option for all women taking hormonal contraception who would like a more natural choice; for those who have never used hormonal contraception and may consider this new opportunity positively, for those who suffer from various menstrual symptoms, related inflammation ("a shorter HFI means much fewer or no symptoms") and, possibly for pre-menopausal women, an opportunity to combine excellent contraception with a definite improvement in their well-being. The pill containing estradiol valerate and dienogest is a contraceptive option that may satisfy women's demands for a more natural contraceptive while offering high reliability, good tolerability, a simple dosing schedule, lighter and shorter withdrawal bleeding, improved anaemia and a reduction in cycle-related symptoms thanks to a shorter Hormone Free Interval, and improved sexuality and general well-being. Communication should focus on women's priorities regarding contraception and their pursuit of a better quality of life while on OC.
Terry, Paul E; Fowles, Jinnet Briggs; Xi, Min; Harvey, Lisa
2011-01-01
PURPOSE. This study compares a traditional worksite-based health promotion program with an activated consumer program and a control program DESIGN. Group randomized controlled trial with 18-month intervention. SETTING. Two large Midwestern companies. SUBJECTS. Three hundred and twenty employees (51% response). INTERVENTION. The traditional health promotion intervention offered population-level campaigns on physical activity, nutrition, and stress management. The activated consumer intervention included population-level campaigns for evaluating health information, choosing a health benefits plan, and understanding the risks of not taking medications as prescribed. The personal development intervention (control group) offered information on hobbies. The interventions also offered individual-level coaching for high risk individuals in both active intervention groups. MEASURES. Health risk status, general health status, consumer activation, productivity, and the ability to evaluate health information. ANALYSIS. Multivariate analyses controlled for baseline differences among the study groups. RESULTS. At the population level, compared with baseline performance, the traditional health promotion intervention improved health risk status, consumer activation, and the ability to recognize reliable health websites. Compared with baseline performance, the activated consumer intervention improved consumer activation, productivity, and the ability to recognize reliable health websites. At the population level, however, only the activated consumer intervention improved any outcome more than the control group did; that outcome was consumer activation. At the individual level for high risk individuals, both traditional health coaching and activated consumer coaching positively affected health risk status and consumer activation. In addition, both coaching interventions improved participant ability to recognize a reliable health website. Consumer activation coaching also significantly improved self-reported productivity. CONCLUSION. An effective intervention can change employee health risk status and activation both at the population level and at the individual high risk level. However, program engagement at the population level was low, indicating that additional promotional strategies, such as greater use of incentives, need to be examined. Less intensive coaching can be as effective as more intensive, albeit both interventions produced modest behavior change and retention in the consumer activation arm was most difficult. Further research is needed concerning recruitment and retention methods that will enable populations to realize the full potential of activated consumerism.
The use of inflatable structures for re-entry of orbiting vehicles
NASA Astrophysics Data System (ADS)
Kendall, Robert T.; Maddox, Arthur R.
1990-10-01
Inflatable recovery systems offer the unique advantage that a large high-drag shape can be stored initially in a relatively small package. The resulting shapes decelerate rapidly with lower heating inputs than other types of re-entry vehicles. Recent developments have led to some light-weight materials, with little thermal protection, can withstand the heating inputs to such vehicles. As a result, inflatable recovery vehicles offer a simple, reliable and economical way to return various vehicles from orbit. This paper examines the application of this concept to a large and a small vehicle with the accompanying dynamics that might be expected. More complex systems could extend the concept to emergency personnel escape systems, payload abort and satellite recovery systems.
Magnetic control systems for large spacecraft with applications to space telescope
NASA Technical Reports Server (NTRS)
Dougherty, H.; Machnick, J.; Nakashima, A.; Henry, J.; Tompetrini, K.
1981-01-01
Magnetic control systems for large space vehicles offer the advantage of a simple, reliable, low cost augmentation to the primary control system. When used for momentum management, a magnetic torque source offers a long life and noncontaminant environment when compared to a mass expulsion torque source. These qualities make such systems suitable for employment with the Space Telescope, which is a long life, high performance vehicle with optics and scientific instruments which would be degraded by contamination due to mass expulsion products. The various applications of magnetic systems on the Space Telescope are considered. The future trend in magnetic control of large space vehicles lies in providing a known three axis reference for backup operations, such as recovery of the primary control mode.
Electrochemical hydrogen sulfide biosensors.
Xu, Tailin; Scafa, Nikki; Xu, Li-Ping; Zhou, Shufeng; Abdullah Al-Ghanem, Khalid; Mahboob, Shahid; Fugetsu, Bunshi; Zhang, Xueji
2016-02-21
The measurement of sulfide, especially hydrogen sulfide, has held the attention of the analytical community due to its unique physiological and pathophysiological roles in biological systems. Electrochemical detection offers a rapid, highly sensitive, affordable, simple, and real-time technique to measure hydrogen sulfide concentration, which has been a well-documented and reliable method. This review details up-to-date research on the electrochemical detection of hydrogen sulfide (ion selective electrodes, polarographic hydrogen sulfide sensors, etc.) in biological samples for potential therapeutic use.
Reliability analysis of single crystal NiAl turbine blades
NASA Technical Reports Server (NTRS)
Salem, Jonathan; Noebe, Ronald; Wheeler, Donald R.; Holland, Fred; Palko, Joseph; Duffy, Stephen; Wright, P. Kennard
1995-01-01
As part of a co-operative agreement with General Electric Aircraft Engines (GEAE), NASA LeRC is modifying and validating the Ceramic Analysis and Reliability Evaluation of Structures algorithm for use in design of components made of high strength NiAl based intermetallic materials. NiAl single crystal alloys are being actively investigated by GEAE as a replacement for Ni-based single crystal superalloys for use in high pressure turbine blades and vanes. The driving force for this research lies in the numerous property advantages offered by NiAl alloys over their superalloy counterparts. These include a reduction of density by as much as a third without significantly sacrificing strength, higher melting point, greater thermal conductivity, better oxidation resistance, and a better response to thermal barrier coatings. The current drawback to high strength NiAl single crystals is their limited ductility. Consequently, significant efforts including the work agreement with GEAE are underway to develop testing and design methodologies for these materials. The approach to validation and component analysis involves the following steps: determination of the statistical nature and source of fracture in a high strength, NiAl single crystal turbine blade material; measurement of the failure strength envelope of the material; coding of statistically based reliability models; verification of the code and model; and modeling of turbine blades and vanes for rig testing.
The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.
Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E
2016-11-01
Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P < 0.001). The 3DWM device yielded correlations of ρ = 0.990, 0.987, 0.996 with P < 0.001 for length, width, and area when compared to manual measurements. The 3DWM device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.
An advanced pitch change mechanism incorporating a hybrid traction drive
NASA Technical Reports Server (NTRS)
Steinetz, B. M.; Loewenthal, S. H.; Sargisson, D. F.; White, G.
1984-01-01
A design of a propeller pitch control mechanism is described that meets the demanding requirements of a high-power, advanced turboprop. In this application, blade twisting moment torque can be comparable to that of the main reduction gearbox output: precise pitch control, reliability and compactness are all at a premium. A key element in the design is a compact, high-ratio hybrid traction drive which offers low torque ripple and high torsional stiffness. The traction drive couples a high speed electric motor/alternator unit to a ball screw that actuates the blade control links. The technical merits of this arrangement and the performance characteristics of the traction drive are discussed.
2D scanning Rotman lens structure for smart collision avoidance sensors
NASA Astrophysics Data System (ADS)
Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek
2004-03-01
Although electronically scanned antenna arrays can provide effective mm-wave search radar sensors, their high cost and complexity are leading to the consideration of alternative beam-forming arrangements. Rotman lenses offer a compact, rugged, reliable, alternative solution. This paper considers the design of a microstrip based Rotman lens for high-resolution, frequency-controlled scanning applications. Its implementation in microstrip is attractive because this technology is low-cost, conformal, and lightweight. A sensor designed for operation at 77 GHz is presented and an ~80° azimuthal scan over a 30 GHz bandwidth is demonstrated.
Using the World-Wide Web to Facilitate Communications of Non-Destructive Evaluation
NASA Technical Reports Server (NTRS)
McBurney, Sean
1995-01-01
The high reliability required for Aeronautical components is a major reason for extensive Nondestructive Testing and Evaluation. Here at Langley Research Center (LaRC), there are highly trained and certified personal to conduct such testing to prevent hazards from occurring in the workplace and on the research projects for the National Aeronautics and Space Administration (NASA). The purpose of my studies was to develop a communication source to educate others of the services and equipment offered here. This was accomplished by creating documents that are accessible to all in the industry via the World Wide Web.
Long-wavelength analyte-sensitive luminescent probes and optical (bio)sensors
Staudinger, Christoph; Borisov, Sergey M
2016-01-01
Long-wavelength luminescent probes and sensors become increasingly popular. They offer the advantage of lower levels of autofluorescence in most biological probes. Due to high penetration depth and low scattering of red and NIR light such probes potentially enable in vivo measurements in tissues and some of them have already reached a high level of reliability required for such applications. This review focuses on the recent progress in development and application of long-wavelength analyte-sensitive probes which can operate both reversibly and irreversibly. Photophysical properties, sensing mechanisms, advantages and limitations of individual probes are discussed. PMID:27134748
Satellite -Based Networks for U-Health & U-Learning
NASA Astrophysics Data System (ADS)
Graschew, G.; Roelofs, T. A.; Rakowsky, S.; Schlag, P. M.
2008-08-01
The use of modern Information and Communication Technologies (ICT) as enabling tools for healthcare services (eHealth) introduces new ways of creating ubiquitous access to high-level medical care for all, anytime and anywhere (uHealth). Satellite communication constitutes one of the most flexible methods of broadband communication offering high reliability and cost-effectiveness of connections meeting telemedicine communication requirements. Global networks and the use of computers for educational purposes stimulate and support the development of virtual universities for e-learning. Especially real-time interactive applications can play an important role in tailored and personalised services.
Improving Reliability of High Power Quasi-CW Laser Diode Arrays Operating in Long Pulse Mode
NASA Technical Reports Server (NTRS)
Amzajerdian, Farzin; Meadows, Byron L.; Barnes, Bruce W.; Lockard, George E.; Singh, Upendra N.; Kavaya, Michael J.; Baker, Nathaniel R.
2006-01-01
Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data of the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.
The advantages of the high voltage solar array for electric propulsion
NASA Technical Reports Server (NTRS)
Sater, B. L.
1973-01-01
The high voltage solar array (HVSA) offers improvements in efficiency, weight, and reliability for the electric propulsion power system. The basic HVSA technology involves designing the solar array to deliver power in the form required by the ion thruster. This paper delves into conventional power processes and problems associated with ion thruster operation using SERT II experience for examples. In this light, the advantages of the HVSA concept for electric propulsion are presented. Tests conducted operating the SERT II thruster system in conjunction with HVSA are discussed. Thruster operation was observed to be normal and in some respects improved.
NASA Astrophysics Data System (ADS)
Sun, Kai; Wu, Hongfei; Cai, Yan; Xing, Yan
2014-06-01
A thermoelectric generator (TEG) is a very important kind of power supply for spacecraft, especially for deep-space missions, due to its long lifetime and high reliability. To develop a practical TEG power supply for spacecraft, a power conditioning stage is indispensable, being employed to convert the varying output voltage of the TEG modules to a definite voltage for feeding batteries or loads. To enhance the system reliability, a power conditioning stage based on analog-circuit maximum-power-point tracking (MPPT) control and a superbuck converter is proposed in this paper. The input of this power conditioning stage is connected to the output of the TEG modules, and the output of this stage is connected to the battery and loads. The superbuck converter is employed as the main circuit, featuring low input current ripples and high conversion efficiency. Since for spacecraft power systems reliable operation is the key target for control circuits, a reset-set flip-flop-based analog circuit is used as the basic control circuit to implement MPPT, being much simpler than digital control circuits and offering higher reliability. Experiments have verified the feasibility and effectiveness of the proposed power conditioning stage. The results show the advantages of the proposed stage, such as maximum utilization of TEG power, small input ripples, and good stability.
van Hooren, Susan; van der Veld, William M.; Hutschemaekers, Giel
2017-01-01
Abstract Despite the use of art therapy in clinical practice, its appreciation and reported beneficial results, no instruments are available to measure specific effects of art therapy among patients with personality disorders cluster B/C in multidisciplinary treatment. In the present study, we described the development and psychometric evaluation of the Self‐expression and Emotion Regulation in Art Therapy Scale (SERATS). Structural validity (exploratory and confirmatory factor analysis), reliability, construct validity and sensitivity to change were examined using two independent databases (n = 335; n = 34) of patients diagnosed with personality disorders cluster B/C. This resulted in a nine‐item effect scale with a single factor with a high internal reliability and high test–retest reliability; it demonstrated discriminant validity and sensitivity to change. In conclusion, the SERATS is brief and content‐valid and offers objective and reliable information on self‐expression and emotion regulation in art therapy among patients with personality disorders cluster B/C. Although more research on construct validity is needed, the SERATS is a promising tool to be applied as an effect scale and as a monitoring tool during art therapy treatment. © 2017 The Authors Personality and Mental Health Published by John Wiley & Sons Ltd PMID:28730717
HIFI-C: a robust and fast method for determining NMR couplings from adaptive 3D to 2D projections.
Cornilescu, Gabriel; Bahrami, Arash; Tonelli, Marco; Markley, John L; Eghbalnia, Hamid R
2007-08-01
We describe a novel method for the robust, rapid, and reliable determination of J couplings in multi-dimensional NMR coupling data, including small couplings from larger proteins. The method, "High-resolution Iterative Frequency Identification of Couplings" (HIFI-C) is an extension of the adaptive and intelligent data collection approach introduced earlier in HIFI-NMR. HIFI-C collects one or more optimally tilted two-dimensional (2D) planes of a 3D experiment, identifies peaks, and determines couplings with high resolution and precision. The HIFI-C approach, demonstrated here for the 3D quantitative J method, offers vital features that advance the goal of rapid and robust collection of NMR coupling data. (1) Tilted plane residual dipolar couplings (RDC) data are collected adaptively in order to offer an intelligent trade off between data collection time and accuracy. (2) Data from independent planes can provide a statistical measure of reliability for each measured coupling. (3) Fast data collection enables measurements in cases where sample stability is a limiting factor (for example in the presence of an orienting medium required for residual dipolar coupling measurements). (4) For samples that are stable, or in experiments involving relatively stronger couplings, robust data collection enables more reliable determinations of couplings in shorter time, particularly for larger biomolecules. As a proof of principle, we have applied the HIFI-C approach to the 3D quantitative J experiment to determine N-C' RDC values for three proteins ranging from 56 to 159 residues (including a homodimer with 111 residues in each subunit). A number of factors influence the robustness and speed of data collection. These factors include the size of the protein, the experimental set up, and the coupling being measured, among others. To exhibit a lower bound on robustness and the potential for time saving, the measurement of dipolar couplings for the N-C' vector represents a realistic "worst case analysis". These couplings are among the smallest currently measured, and their determination in both isotropic and anisotropic media demands the highest measurement precision. The new approach yielded excellent quantitative agreement with values determined independently by the conventional 3D quantitative J NMR method (in cases where sample stability in oriented media permitted these measurements) but with a factor of 2-5 in time savings. The statistical measure of reliability, measuring the quality of each RDC value, offers valuable adjunct information even in cases where modest time savings may be realized.
Silicon Nanophotonics for Many-Core On-Chip Networks
NASA Astrophysics Data System (ADS)
Mohamed, Moustafa
Number of cores in many-core architectures are scaling to unprecedented levels requiring ever increasing communication capacity. Traditionally, architects follow the path of higher throughput at the expense of latency. This trend has evolved into being problematic for performance in many-core architectures. Moreover, the trends of power consumption is increasing with system scaling mandating nontraditional solutions. Nanophotonics can address these problems, offering benefits in the three frontiers of many-core processor design: Latency, bandwidth, and power. Nanophotonics leverage circuit-switching flow control allowing low latency; in addition, the power consumption of optical links is significantly lower compared to their electrical counterparts at intermediate and long links. Finally, through wave division multiplexing, we can keep the high bandwidth trends without sacrificing the throughput. This thesis focuses on realizing nanophotonics for communication in many-core architectures at different design levels considering reliability challenges that our fabrication and measurements reveal. First, we study how to design on-chip networks for low latency, low power, and high bandwidth by exploiting the full potential of nanophotonics. The design process considers device level limitations and capabilities on one hand, and system level demands in terms of power and performance on the other hand. The design involves the choice of devices, designing the optical link, the topology, the arbitration technique, and the routing mechanism. Next, we address the problem of reliability in on-chip networks. Reliability not only degrades performance but can block communication. Hence, we propose a reliability-aware design flow and present a reliability management technique based on this flow to address reliability in the system. In the proposed flow reliability is modeled and analyzed for at the device, architecture, and system level. Our reliability management technique is superior to existing solutions in terms of power and performance. In fact, our solution can scale to thousand core with low overhead.
NASA Technical Reports Server (NTRS)
Ferlita, F.
1989-01-01
The Advanced Launch Systems (ALS) Advanced Development Oxidizer Turbopump Program has designed, fabricated and demonstrated a low cost, highly reliable oxidizer turbopump for the Space Transportation Engine that minimizes the recurring cost for the ALS engines. Pratt and Whitney's (P and W's) plan for integrating the analyses, testing, fabrication, and other program efforts is addressed. This plan offers a comprehensive description of the total effort required to design, fabricate, and test the ALS oxidizer turbopump. The proposed ALS oxidizer turbopump reduces turbopump costs over current designs by taking advantage of design simplicity and state-of-the-art materials and producibility features without compromising system reliability. This is accomplished by selecting turbopump operating conditions that are within known successful operating regions and by using proven manufacturing techniques.
A Theory-Grounded Measure of Adolescents’ Response to a Media Literacy Intervention
Greene, Kathryn; Yanovitzky, Itzhak; Carpenter, Amanda; Banerjee, Smita C.; Magsamen-Conrad, Kate; Hecht, Michael L.; Elek, Elvira
2016-01-01
Media literacy interventions offer promising avenues for the prevention of risky health behaviors among children and adolescents, but current literature remains largely equivocal about their efficacy. The primary objective of this study was to develop and test theoretically-grounded measures of audiences’ degree of engagement with the content of media literacy programs based on the recognition that engagement (and not participation per se) can better explain and predict individual variations in the effects of these programs. We tested the validity and reliability of a measure of engagement with two different samples of 10th grade high school students who participated in a pilot and actual test of a brief media literacy curriculum. Four message evaluation factors (involvement, perceived novelty, critical thinking, personal reflection) emerged and demonstrate acceptable reliability. PMID:28042522
Hawkins, Keith A; Jennings, Danna; Vincent, Andrea S; Gilliland, Kirby; West, Adrienne; Marek, Kenneth
2012-08-01
The automated neuropsychological assessment metrics battery-4 for PD offers the promise of a computerized approach to cognitive assessment. To assess its utility, the ANAM4-PD was administered to 72 PD patients and 24 controls along with a traditional battery. Reliability was assessed by retesting 26 patients. The cognitive efficiency score (CES; a global score) exhibited high reliability (r = 0.86). Constituent variables exhibited lower reliability. The CES correlated strongly with the traditional battery global score, but displayed weaker relationships to UPDRS scores than the traditional score. Multivariate analysis of variance revealed a significant difference between the patient and control groups in ANAM4-PD performance, with three ANAM4-PD tests, math, tower, and pursuit tracking, displaying sizeable differences. In discriminant analyses these variables were as effective as the total ANAM4-PD in classifying cases designated as impaired based on traditional variables. Principal components analyses uncovered fewer factors in the ANAM4-PD relative to the traditional battery. ANAM4-PD variables correlated at higher levels with traditional motor and processing speed variables than with untimed executive, intellectual or memory variables. The ANAM4-PD displays high global reliability, but variable subtest reliability. The battery assesses a narrower range of cognitive functions than traditional tests, and discriminates between patients and controls less effectively. Three ANAM4-PD tests, pursuit tracking, math, and tower performed as well as the total ANAM4-PD in classifying patients as cognitively impaired. These findings could guide the refinement of the ANAM4-PD as an efficient method of screening for mild to moderate cognitive deficits in PD patients. Copyright © 2012 Elsevier Ltd. All rights reserved.
[Do Multiplex PCR techniques displace classical cultures in microbiology?].
Auckenthaler, Raymond; Risch, Martin
2015-02-01
Multiplex PCR technologies progressively find their way in clinical microbiology. This technique allows the simultaneous amplification of multiple DNA targets in a single test run for the identification of pathogens up to the species level. Various pathogens of infectious diseases can be detected by a symptom-oriented approach clearly and quickly with high reliability. Essentially multiplex PCR panels are available for clarification of gastrointestinal, respiratory, sexually transmitted infections and meningitis. Today's offer from industry, university hospitals and large private laboratories of Switzerland is tabulated and commented.
Reliability Assessment Approach for Stirling Convertors and Generators
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Schreiber, Jeffrey G.; Zampino, Edward; Best, Timothy
2004-01-01
Stirling power conversion is being considered for use in a Radioisotope Power System for deep-space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power. Quantifying the reliability of a Radioisotope Power System that utilizes Stirling power conversion technology is important in developing and demonstrating the capability for long-term success. A description of the Stirling power convertor is provided, along with a discussion about some of the key components. Ongoing efforts to understand component life, design variables at the component and system levels, related sources, and the nature of uncertainties is discussed. The requirement for reliability also is discussed, and some of the critical areas of concern are identified. A section on the objectives of the performance model development and a computation of reliability is included to highlight the goals of this effort. Also, a viable physics-based reliability plan to model the design-level variable uncertainties at the component and system levels is outlined, and potential benefits are elucidated. The plan involves the interaction of different disciplines, maintaining the physical and probabilistic correlations at all the levels, and a verification process based on rational short-term tests. In addition, both top-down and bottom-up coherency were maintained to follow the physics-based design process and mission requirements. The outlined reliability assessment approach provides guidelines to improve the design and identifies governing variables to achieve high reliability in the Stirling Radioisotope Generator design.
NASA reliability preferred practices for design and test
NASA Technical Reports Server (NTRS)
1991-01-01
Given here is a manual that was produced to communicate within the aerospace community design practices that have contributed to NASA mission success. The information represents the best technical advice that NASA has to offer on reliability design and test practices. Topics covered include reliability practices, including design criteria, test procedures, and analytical techniques that have been applied to previous space flight programs; and reliability guidelines, including techniques currently applied to space flight projects, where sufficient information exists to certify that the technique will contribute to mission success.
Tracking reliability for space cabin-borne equipment in development by Crow model.
Chen, J D; Jiao, S J; Sun, H L
2001-12-01
Objective. To study and track the reliability growth of manned spaceflight cabin-borne equipment in the course of its development. Method. A new technique of reliability growth estimation and prediction, which is composed of the Crow model and test data conversion (TDC) method was used. Result. The estimation and prediction value of the reliability growth conformed to its expectations. Conclusion. The method could dynamically estimate and predict the reliability of the equipment by making full use of various test information in the course of its development. It offered not only a possibility of tracking the equipment reliability growth, but also the reference for quality control in manned spaceflight cabin-borne equipment design and development process.
Assessing Performance in Shoulder Arthroscopy: The Imperial Global Arthroscopy Rating Scale (IGARS).
Bayona, Sofia; Akhtar, Kash; Gupte, Chinmay; Emery, Roger J H; Dodds, Alexander L; Bello, Fernando
2014-07-02
Surgical training is undergoing major changes with reduced resident work hours and an increasing focus on patient safety and surgical aptitude. The aim of this study was to create a valid, reliable method for an assessment of arthroscopic skills that is independent of time and place and is designed for both real and simulated settings. The validity of the scale was tested using a virtual reality shoulder arthroscopy simulator. The study consisted of two parts. In the first part, an Imperial Global Arthroscopy Rating Scale for assessing technical performance was developed using a Delphi method. Application of this scale required installing a dual-camera system to synchronously record the simulator screen and body movements of trainees to allow an assessment that is independent of time and place. The scale includes aspects such as efficient portal positioning, angles of instrument insertion, proficiency in handling the arthroscope and adequately manipulating the camera, and triangulation skills. In the second part of the study, a validation study was conducted. Two experienced arthroscopic surgeons, blinded to the identities and experience of the participants, each assessed forty-nine subjects performing three different tests using the Imperial Global Arthroscopy Rating Scale. Results were analyzed using two-way analysis of variance with measures of absolute agreement. The intraclass correlation coefficient was calculated for each test to assess inter-rater reliability. The scale demonstrated high internal consistency (Cronbach alpha, 0.918). The intraclass correlation coefficient demonstrated high agreement between the assessors: 0.91 (p < 0.001). Construct validity was evaluated using Kruskal-Wallis one-way analysis of variance (chi-square test, 29.826; p < 0.001), demonstrating that the Imperial Global Arthroscopy Rating Scale distinguishes significantly between subjects with different levels of experience utilizing a virtual reality simulator. The Imperial Global Arthroscopy Rating Scale has a high internal consistency and excellent inter-rater reliability and offers an approach for assessing technical performance in basic arthroscopy on a virtual reality simulator. The Imperial Global Arthroscopy Rating Scale provides detailed information on surgical skills. Although it requires further validation in the operating room, this scale, which is independent of time and place, offers a robust and reliable method for assessing arthroscopic technical skills. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
NASA Astrophysics Data System (ADS)
Zhang, Chongfu; Wang, Zhengsuan; Jin, Wei; Qiu, Kun
2012-11-01
A novel realization method of the optical virtual private networks (OVPN) over multiprotocol label switching/optical packet switching (MPLS/OPS) networks is proposed. In this scheme, the introduction of MPLS control plane makes OVPN over OPS networks more reliable and easier; OVPN makes use of the concept of high reconfiguration of light-paths offered by MPLS, to set up secure tunnels of high bandwidth across intelligent OPS networks. Through resource management, the signal mechanism, connection control, and the architecture of the creation and maintenance of OVPN are efficiently realized. We also present an OVPN architecture with two traffic priorities, which is used to analyze the capacity, throughput, delay time of the proposed networks, and the packet loss rate performance of the OVPN over MPLS/OPS networks based on full mesh topology. The results validate the applicability of such reliable connectivity to high quality services in the OVPN over MPLS/OPS networks. Along with the results, the feasibility of the approach as the basis for the next generation networks is demonstrated and discussed.
Yu, Hong; Gao, Feng; Jiang, Liren; Ma, Shuoxin
2017-09-15
The aim was to develop scalable Whole Slide Imaging (sWSI), a WSI system based on mainstream smartphones coupled with regular optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry objective lenses of different magnifications, and reasonably high throughput. These performance metrics should be evaluated by expert pathologists and match those of high-end scanners. The aim was to develop scalable Whole Slide Imaging (sWSI), a whole slide imaging system based on smartphones coupled with optical microscopes. This ultra-low-cost solution should offer diagnostic-ready imaging quality on par with standalone scanners, supporting both oil and dry object lens of different magnification. All performance metrics should be evaluated by expert pathologists and match those of high-end scanners. In the sWSI design, the digitization process is split asynchronously between light-weight clients on smartphones and powerful cloud servers. The client apps automatically capture FoVs at up to 12-megapixel resolution and process them in real-time to track the operation of users, then give instant feedback of guidance. The servers first restitch each pair of FoVs, then automatically correct the unknown nonlinear distortion introduced by the lens of the smartphone on the fly, based on pair-wise stitching, before finally combining all FoVs into one gigapixel VS for each scan. These VSs can be viewed using Internet browsers anywhere. In the evaluation experiment, 100 frozen section slides from patients randomly selected among in-patients of the participating hospital were scanned by both a high-end Leica scanner and sWSI. All VSs were examined by senior pathologists whose diagnoses were compared against those made using optical microscopy as ground truth to evaluate the image quality. The sWSI system is developed for both Android and iPhone smartphones and is currently being offered to the public. The image quality is reliable and throughput is approximately 1 FoV per second, yielding a 15-by-15 mm slide under 20X object lens in approximately 30-35 minutes, with little training required for the operator. The expected cost for setup is approximately US $100 and scanning each slide costs between US $1 and $10, making sWSI highly cost-effective for infrequent or low-throughput usage. In the clinical evaluation of sample-wise diagnostic reliability, average accuracy scores achieved by sWSI-scan-based diagnoses were as follows: 0.78 for breast, 0.88 for uterine corpus, 0.68 for thyroid, and 0.50 for lung samples. The respective low-sensitivity rates were 0.05, 0.05, 0.13, and 0.25 while the respective low-specificity rates were 0.18, 0.08, 0.20, and 0.25. The participating pathologists agreed that the overall quality of sWSI was generally on par with that produced by high-end scanners, and did not affect diagnosis in most cases. Pathologists confirmed that sWSI is reliable enough for standard diagnoses of most tissue categories, while it can be used for quick screening of difficult cases. As an ultra-low-cost alternative to whole slide scanners, diagnosis-ready VS quality and robustness for commercial usage is achieved in the sWSI solution. Operated on main-stream smartphones installed on normal optical microscopes, sWSI readily offers affordable and reliable WSI to resource-limited or infrequent clinical users. ©Hong Yu, Feng Gao, Liren Jiang, Shuoxin Ma. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 15.09.2017.
Distribution System Reliability Analysis for Smart Grid Applications
NASA Astrophysics Data System (ADS)
Aljohani, Tawfiq Masad
Reliability of power systems is a key aspect in modern power system planning, design, and operation. The ascendance of the smart grid concept has provided high hopes of developing an intelligent network that is capable of being a self-healing grid, offering the ability to overcome the interruption problems that face the utility and cost it tens of millions in repair and loss. To address its reliability concerns, the power utilities and interested parties have spent extensive amount of time and effort to analyze and study the reliability of the generation and transmission sectors of the power grid. Only recently has attention shifted to be focused on improving the reliability of the distribution network, the connection joint between the power providers and the consumers where most of the electricity problems occur. In this work, we will examine the effect of the smart grid applications in improving the reliability of the power distribution networks. The test system used in conducting this thesis is the IEEE 34 node test feeder, released in 2003 by the Distribution System Analysis Subcommittee of the IEEE Power Engineering Society. The objective is to analyze the feeder for the optimal placement of the automatic switching devices and quantify their proper installation based on the performance of the distribution system. The measures will be the changes in the reliability system indices including SAIDI, SAIFI, and EUE. The goal is to design and simulate the effect of the installation of the Distributed Generators (DGs) on the utility's distribution system and measure the potential improvement of its reliability. The software used in this work is DISREL, which is intelligent power distribution software that is developed by General Reliability Co.
Reliability, Compliance, and Security in Web-Based Course Assessments
ERIC Educational Resources Information Center
Bonham, Scott
2008-01-01
Pre- and postcourse assessment has become a very important tool for education research in physics and other areas. The web offers an attractive alternative to in-class paper administration, but concerns about web-based administration include reliability due to changes in medium, student compliance rates, and test security, both question leakage…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stewart, Gary
The primary objective of this project was to demonstrate the feasibility and reliability of utilizing high-temperature superconducting (HTS) materials in a Transmission Level Superconducting Fault Current Limiter (SFCL) application. During the project, the type of high-temperature superconducting material used evolved from 1 st generation (1G) BSCCO-2212 melt cast bulk high-temperature superconductors to 2 nd generation (2G) YBCO-based high-temperature superconducting tape. The SFCL employed SuperPower's “Matrix” technology, that offers modular features to enable scale up to transmission voltage levels. The SFCL consists of individual modules that contain elements and parallel inductors that assist in carrying the current during the fault. Amore » number of these modules are arranged in an m x n array to form the current-limiting matrix.« less
An advanced pitch change mechanism incorporating a hybrid traction drive
NASA Technical Reports Server (NTRS)
Steinetz, B. M.; Sargisson, D. F.; White, G.; Loewenthal, S. H.
1984-01-01
A design of a propeller pitch control mechanism is described that meets the demanding requirements of a high-power, advanced turboprop. In this application, blade twisting moment torque can be comparable to that of the main reduction gearbox output: precise pitch control, reliability and compactness are all at a premium. A key element in the design is a compact, high-ratio hybrid traction drive which offers low torque ripple and high torsional stiffness. The traction drive couples a high speed electric motor/alternator unit to a ball screw that actuates the blade control links. The technical merits of this arrangement and the performance characteristics of the traction drive are discussed. Comparisons are made to the more conventional pitch control mechanisms.
Maruo, Shoji; Hasegawa, Takuya; Yoshimura, Naoki
2009-11-09
In high-precision two-photon microfabrication of three-dimensional (3-D) polymeric microstructures, supercritical CO(2) drying was employed to reduce surface tension, which tends to cause the collapse of micro/nano structures. Use of supercritical drying allowed high-aspect ratio microstructures, such as micropillars and cantilevers, to be fabricated. We also propose a single-anchor supporting method to eliminate non-uniform shrinkage of polymeric structures otherwise caused by attachment to the substrate. Use of this method permitted frame models such as lattices to be produced without harmful distortion. The combination of supercritical CO(2) drying and the single-anchor supporting method offers reliable high-precision microfabrication of sophisticated, fragile 3-D micro/nano structures.
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.
Long life, low cost, rechargeable AgZn battery for non-military applications
NASA Astrophysics Data System (ADS)
Brown, Curtis C.
1996-03-01
Of the rechargeable (secondary) battery systems with mature technology, the silver oxide-zinc system (AgZn) safely offers the highest power and energy (watts and watt hours) per unit of volume and mass. As a result they have long been used for aerospace and defense applications where they have also proven their high reliability. In the past, the expense associated with the cost of silver and the resulting low production volume have limited their commercial application. However, the relative low cost of silver now make this system feasible in many applications where high energy and reliability are required. One area of commercial potential is power for a new generation of sophisticated, portable medical equipment. AgZn batteries have recently proven ``enabling technology'' for power critical, advanced medical devices. By extending the cycle calendar life to the system (offers both improved performance and lower operating cost), a combination is achieved which may enable a wide range of future electrical devices. Other areas where AgZn batteries have been used in nonmilitary applications to provide power to aid in the development of commercial equipment have been: (a) Electrically powered vehicles; (b) Remote sensing in nuclear facilities; (c) Special effects equipment for movies; (d) Remote sensing in petroleum pipe lines; (e) Portable computers; (f) Fly by wire systems for commercial aircraft; and (g) Robotics. However none of these applications have progressed to the level where the volume required will significantly lower cost.
Psychometrics Matter in Health Behavior: A Long-term Reliability Generalization Study.
Pickett, Andrew C; Valdez, Danny; Barry, Adam E
2017-09-01
Despite numerous calls for increased understanding and reporting of reliability estimates, social science research, including the field of health behavior, has been slow to respond and adopt such practices. Therefore, we offer a brief overview of reliability and common reporting errors; we then perform analyses to examine and demonstrate the variability of reliability estimates by sample and over time. Using meta-analytic reliability generalization, we examined the variability of coefficient alpha scores for a well-designed, consistent, nationwide health study, covering a span of nearly 40 years. For each year and sample, reliability varied. Furthermore, reliability was predicted by a sample characteristic that differed among age groups within each administration. We demonstrated that reliability is influenced by the methods and individuals from which a given sample is drawn. Our work echoes previous calls that psychometric properties, particularly reliability of scores, are important and must be considered and reported before drawing statistical conclusions.
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
NASA Astrophysics Data System (ADS)
Takamatsu, Seiichi; Lonjaret, Thomas; Crisp, Dakota; Badier, Jean-Michel; Malliaras, George G.; Ismailova, Esma
2015-10-01
Wearable sensors are receiving a great deal of attention as they offer the potential to become a key technological tool for healthcare. In order for this potential to come to fruition, new electroactive materials endowing high performance need to be integrated with textiles. Here we present a simple and reliable technique that allows the patterning of conducting polymers on textiles. Electrodes fabricated using this technique showed a low impedance contact with human skin, were able to record high quality electrocardiograms at rest, and determine heart rate even when the wearer was in motion. This work paves the way towards imperceptible electrophysiology sensors for human health monitoring.
NASA Astrophysics Data System (ADS)
1982-01-01
Robotic welding has been of interest to industrial firms because it offers higher productivity at lower cost than manual welding. There are some systems with automated arc guidance available, but they have disadvantages, such as limitations on types of materials or types of seams that can be welded; susceptibility to stray electrical signals; restricted field of view; or tendency to contaminate the weld seam. Wanting to overcome these disadvantages, Marshall Space Flight Center, aided by Hayes International Corporation, developed system that uses closed-circuit TV signals for automatic guidance of the welding torch. NASA granted license to Combined Technologies, Inc. for commercial application of the technology. They developed a refined and improved arc guidance system. CTI in turn, licensed the Merrick Corporation, also of Nashville, for marketing and manufacturing of the new system, called the CT2 Optical Trucker. CT2 is a non-contracting system that offers adaptability to broader range of welding jobs and provides greater reliability in high speed operation. It is extremely accurate and can travel at high speed of up to 150 inches per minute.
Characterisation and Modification of Thermally Stable High Explosives for Laser Flyer Applications
NASA Astrophysics Data System (ADS)
Parker, A.; Claridge, R. P.; Proud, W. G.; Johnson, N. A.
2007-12-01
Laser initiation offers improved weapon survivability, versatility and greater Insensitive Munitions (IM) compliance. Detonators based on laser-driven flyers are less vulnerable to electrical initiation and can be based on insensitive secondary explosives. Additionally, this technology will offer advantages in terms of improved flexibility and reliability. Hexanitrostilbene (HNS) and nonanitro-m-terphenyl (NONA) were selected for investigation at QinetiQ as their increased thermal stability over conventional explosives makes them ideal candidates for use in insensitive munition compliant applications. The response of these materials to short duration high-amplitude shock impulses provided by exploding foil initiators (EFI), the electrical equivalent of a laser-driven flyer system, was investigated. Preparation techniques including sonication and the incorporation of additives were used to sensitize the materials to flyer impact, yet maintain their insensitivity to external hazards. Sonication significantly reduced the particle size of both HNS and NONA. The reduced-size explosives exhibited increased sensitivity to EFI impact than the starting materials.
Gates, Kathleen M; Molenaar, Peter C M
2012-10-15
At its best, connectivity mapping can offer researchers great insight into how spatially disparate regions of the human brain coordinate activity during brain processing. A recent investigation conducted by Smith and colleagues (2011) on methods for estimating connectivity maps suggested that those which attempt to ascertain the direction of influence among ROIs rarely provide reliable results. Another problem gaining increasing attention is heterogeneity in connectivity maps. Most group-level methods require that the data come from homogeneous samples, and misleading findings may arise from current methods if the connectivity maps for individuals vary across the sample (which is likely the case). The utility of maps resulting from effective connectivity on the individual or group levels is thus diminished because they do not accurately inform researchers. The present paper introduces a novel estimation technique for fMRI researchers, Group Iterative Multiple Model Estimation (GIMME), which demonstrates that using information across individuals assists in the recovery of the existence of connections among ROIs used by Smith and colleagues (2011) and the direction of the influence. Using heterogeneous in-house data, we demonstrate that GIMME offers a unique improvement over current approaches by arriving at reliable group and individual structures even when the data are highly heterogeneous across individuals comprising the group. An added benefit of GIMME is that it obtains reliable connectivity map estimates equally well using the data from resting state, block, or event-related designs. GIMME provides researchers with a powerful, flexible tool for identifying directed connectivity maps at the group and individual levels. Copyright © 2012 Elsevier Inc. All rights reserved.
Wang, Tao; Huang, Jiang-hua; Lin, Lin; Zhan, Chang'an A
2013-01-01
To obtain reliable transient auditory evoked potentials (AEPs) from EEGs recorded using high stimulus rate (HSR) paradigm, it is critical to design the stimulus sequences of appropriate frequency properties. Traditionally, the individual stimulus events in a stimulus sequence occur only at discrete time points dependent on the sampling frequency of the recording system and the duration of stimulus sequence. This dependency likely causes the implementation of suboptimal stimulus sequences, sacrificing the reliability of resulting AEPs. In this paper, we explicate the use of continuous-time stimulus sequence for HSR paradigm, which is independent of the discrete electroencephalogram (EEG) recording system. We employ simulation studies to examine the applicability of the continuous-time stimulus sequences and the impacts of sampling frequency on AEPs in traditional studies using discrete-time design. Results from these studies show that the continuous-time sequences can offer better frequency properties and improve the reliability of recovered AEPs. Furthermore, we find that the errors in the recovered AEPs depend critically on the sampling frequencies of experimental systems, and their relationship can be fitted using a reciprocal function. As such, our study contributes to the literature by demonstrating the applicability and advantages of continuous-time stimulus sequences for HSR paradigm and by revealing the relationship between the reliability of AEPs and sampling frequencies of the experimental systems when discrete-time stimulus sequences are used in traditional manner for the HSR paradigm.
An improved grey model for the prediction of real-time GPS satellite clock bias
NASA Astrophysics Data System (ADS)
Zheng, Z. Y.; Chen, Y. Q.; Lu, X. S.
2008-07-01
In real-time GPS precise point positioning (PPP), real-time and reliable satellite clock bias (SCB) prediction is a key to implement real-time GPS PPP. It is difficult to hold the nuisance and inenarrable performance of space-borne GPS satellite atomic clock because of its high-frequency, sensitivity and impressionable, it accords with the property of grey model (GM) theory, i. e. we can look on the variable process of SCB as grey system. Firstly, based on limits of quadratic polynomial (QP) and traditional GM to predict SCB, a modified GM (1,1) is put forward to predict GPS SCB in this paper; and then, taking GPS SCB data for example, we analyzed clock bias prediction with different sample interval, the relationship between GM exponent and prediction accuracy, precision comparison of GM to QP, and concluded the general rule of different type SCB and GM exponent; finally, to test the reliability and validation of the modified GM what we put forward, taking IGS clock bias ephemeris product as reference, we analyzed the prediction precision with the modified GM, It is showed that the modified GM is reliable and validation to predict GPS SCB and can offer high precise SCB prediction for real-time GPS PPP.
Low Temperature Regenerators for Zero Boil-Off Liquid Hydrogen Pulse Tube Cryocoolers
NASA Technical Reports Server (NTRS)
Salerno, Louis J.; Kashani, Ali; Helvensteijn, Ben; Kittel, Peter; Arnoldm James O. (Technical Monitor)
2002-01-01
Recently, a great deal of attention has been focused on zero boil-off (ZBO) propellant storage as a means of minimizing the launch mass required for long-term exploration missions. A key component of ZBO systems is the cooler. Pulse tube coolers offer the advantage of zero moving mass at the cold head, and recent advances in lightweight, high efficiency cooler technology have paved the way for reliable liquid oxygen (LOx) temperature coolers to be developed which are suitable for flight ZBO systems. Liquid hydrogen (LH2) systems, however, are another matter. For ZBO liquid hydrogen systems, cooling powers of 1-5 watts are required at 20 K. The final development from tier for these coolers is to achieve high efficiency and reliability at lower operating temperatures. Most of the life-limiting issues of flight Stirling and pulse tube coolers are associated with contamination, drive mechanisms, and drive electronics. These problems are well in hand in the present generation coolers. The remaining efficiency and reliability issues reside with the low temperature regenerators. This paper will discuss advances to be made in regenerators for pulse tube LH2 ZBO coolers, present some historical background, and discuss recent progress in regenerator technology development using alloys of erbium.
ERIC Educational Resources Information Center
Islam, Muhammad Faysal
2013-01-01
Cloud computing offers the advantage of on-demand, reliable and cost efficient computing solutions without the capital investment and management resources to build and maintain in-house data centers and network infrastructures. Scalability of cloud solutions enable consumers to upgrade or downsize their services as needed. In a cloud environment,…
ERIC Educational Resources Information Center
Jang, Yuh; Chang, Tzyh-Chyang; Lin, Keh-Chung
2009-01-01
Physical capacity evaluations (PCEs) are important and frequently offered services in work practice. This study investigates the reliability and validity of the National Taiwan University Hospital Physical Capacity Evaluation (NTUH PCE) on a sample of 149 participants consisted of three groups: 45 intellectual disability (ID), 56 mental illness…
Hydrocarbon-Seeded Ignition System for Small Spacecraft Thrusters Using Ionic Liquid Propellants
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Merkley, Daniel P.; Eilers, Shannon D.; Taylor, Terry L.
2013-01-01
"Green" propellants based on Ionic-liquids (ILs) like Ammonium DiNitramide and Hydroxyl Ammonium Nitrate have recently been developed as reduced-hazard replacements for hydrazine. Compared to hydrazine, ILs offer up to a 50% improvement in available density-specific impulse. These materials present minimal vapor hazard at room temperature, and this property makes IL's potentially advantageous for "ride-share" launch opportunities where hazards introduced by hydrazine servicing are cost-prohibitive. Even though ILs present a reduced hazard compared to hydrazine, in crystalline form they are potentially explosive and are mixed in aqueous solutions to buffer against explosion. Unfortunately, the high water content makes IL-propellants difficult to ignite and currently a reliable "coldstart" capability does not exist. For reliable ignition, IL-propellants catalyst beds must be pre-heated to greater than 350 C before firing. The required preheat power source is substantial and presents a significant disadvantage for SmallSats where power budgets are extremely limited. Design and development of a "micro-hybrid" igniter designed to act as a "drop-in" replacement for existing IL catalyst beds is presented. The design requires significantly lower input energy and offers a smaller overall form factor. Unlike single-use "squib" pyrotechnic igniters, the system allows the gas generation cycle to be terminated and reinitiated on demand.
[State of supply services for industrial hygiene and safety in Colombia].
Varona, Marcela E; Torres, Carlos Humberto; Díaz, Sonia M; Palma, Ruth Marién; Checa, Diana Milena; Conde, Juan Vicente
2012-01-01
Institutions that supply occupational health services must offer services that are reliable and of high quality across the spectrum of industrial hygiene and safety needs. Services for occupational health were identified at several institutions, and the technical quality and reliability of these services were compared in different regions of Colombia. This descriptive study identified the services available for industrial hygiene and safety in 15 cities of Colombia. A survey was conducted in 192 institutions offering such services and a statistical analysis of these results was undertaken. This sample was taken from a nationwide list of institutions purportedly licensed for this activity. Thirty-two percent (61) of the evaluated institutions provided hygiene services, and 48% (93) provided safety services. The range of health services was provided on a subcontract basis both for professional personnel and the equipment. Six institutions in the area of industrial hygiene and 1 in the area of industrial security were supplying services with pending or suspended institutional licenses. Deficiencies in the quality, infrastructure and levels of automation were identified at institutions that supply services of hygiene and industrial security. The resulting recommendatios are that the Ministry of the Social Protection fortifies mechanisms for (1) the evaluation and control of the supplied services, and (2) verify that the institutional activity is in accordance with current and valid licensing.
O’Connor, David; Potler, Natan Vega; Kovacs, Meagan; Xu, Ting; Ai, Lei; Pellman, John; Vanderwal, Tamara; Parra, Lucas C.; Cohen, Samantha; Ghosh, Satrajit; Escalera, Jasmine; Grant-Villegas, Natalie; Osman, Yael; Bui, Anastasia; Craddock, R. Cameron
2017-01-01
Abstract Background: Although typically measured during the resting state, a growing literature is illustrating the ability to map intrinsic connectivity with functional MRI during task and naturalistic viewing conditions. These paradigms are drawing excitement due to their greater tolerability in clinical and developing populations and because they enable a wider range of analyses (e.g., inter-subject correlations). To be clinically useful, the test-retest reliability of connectivity measured during these paradigms needs to be established. This resource provides data for evaluating test-retest reliability for full-brain connectivity patterns detected during each of four scan conditions that differ with respect to level of engagement (rest, abstract animations, movie clips, flanker task). Data are provided for 13 participants, each scanned in 12 sessions with 10 minutes for each scan of the four conditions. Diffusion kurtosis imaging data was also obtained at each session. Findings: Technical validation and demonstrative reliability analyses were carried out at the connection-level using the Intraclass Correlation Coefficient and at network-level representations of the data using the Image Intraclass Correlation Coefficient. Variation in intrinsic functional connectivity across sessions was generally found to be greater than that attributable to scan condition. Between-condition reliability was generally high, particularly for the frontoparietal and default networks. Between-session reliabilities obtained separately for the different scan conditions were comparable, though notably lower than between-condition reliabilities. Conclusions: This resource provides a test-bed for quantifying the reliability of connectivity indices across subjects, conditions and time. The resource can be used to compare and optimize different frameworks for measuring connectivity and data collection parameters such as scan length. Additionally, investigators can explore the unique perspectives of the brain's functional architecture offered by each of the scan conditions. PMID:28369458
Green, Dido; Meroz, Anat; Margalit, Adi Edit; Ratzon, Navah Z
2012-11-01
This study examines a potential instrument for measurement of typing postures of children. This paper describes inter-rater, test-retest reliability and concurrent validity of the Keyboard Personal Computer Style instrument (K-PeCS), an observational measurement of postures and movements during keyboarding, for use with children. Two trained raters independently rated videos of 24 children (aged 7-10 years). Six children returned one week later for identifying test-retest reliability. Concurrent validity was assessed by comparing ratings obtained using the K-PECS to scores from a 3D motion analysis system. Inter-rater reliability was moderate to high for 12 out of 16 items (Kappa: 0.46 to 1.00; correlation coefficients: 0.77-0.95) and test-retest reliability varied across items (Kappa: 0.25 to 0.67; correlation coefficients: r = 0.20 to r = 0.95). Concurrent validity compared favourably across arm pathlength, wrist extension and ulnar deviation. In light of the limitations of other tools the K-PeCS offers a fairly affordable, reliable and valid instrument to address the gap for measurement of typing styles of children, despite the shortcomings of some items. However further research is required to refine the instrument for use in evaluating typing among children. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
NASA Astrophysics Data System (ADS)
Vahdani, Behnam; Tavakkoli-Moghaddam, Reza; Jolai, Fariborz; Baboli, Arman
2013-06-01
This article seeks to offer a systematic approach to establishing a reliable network of facilities in closed loop supply chains (CLSCs) under uncertainties. Facilities that are located in this article concurrently satisfy both traditional objective functions and reliability considerations in CLSC network designs. To attack this problem, a novel mathematical model is developed that integrates the network design decisions in both forward and reverse supply chain networks. The model also utilizes an effective reliability approach to find a robust network design. In order to make the results of this article more realistic, a CLSC for a case study in the iron and steel industry has been explored. The considered CLSC is multi-echelon, multi-facility, multi-product and multi-supplier. Furthermore, multiple facilities exist in the reverse logistics network leading to high complexities. Since the collection centres play an important role in this network, the reliability concept of these facilities is taken into consideration. To solve the proposed model, a novel interactive hybrid solution methodology is developed by combining a number of efficient solution approaches from the recent literature. The proposed solution methodology is a bi-objective interval fuzzy possibilistic chance-constraint mixed integer linear programming (BOIFPCCMILP). Finally, computational experiments are provided to demonstrate the applicability and suitability of the proposed model in a supply chain environment and to help decision makers facilitate their analyses.
Imaging and intervention in the gastrointestinal tract in children.
Kaye, Robin D; Towbin, R B
2002-09-01
Vascular and interventional techniques have become an integral component of modern pediatric healthcare. Minimally invasive procedures of the gastrointestinal tract now comprise a large part of any active pediatric interventional practice. Magnetic resonance cholangiopancreatography offers a reliable, non-invasive means to evaluate patients with possible pancreatic or biliary pathology. This article reviews treatment of esophageal strictures and placement of gastronomy and gastrojejunostomy tubes and discusses new developments. Placement of percutaneous cecostomy tubes is a relatively new procedure that creatively uses the techniques developed for placement of percutaneous gastronomy tubes. This procedure offers significant benefits and lasting positive lifestyle changes for patients suffering from fecal incontinence. Liver biopsy in high-risk patients can be performed safely using measures designed to significantly decrease the risk of post-biopsy hemorrhage, such as track embolization or the transjugular approach.
Loop Diuretics in the Treatment of Hypertension.
Malha, Line; Mann, Samuel J
2016-04-01
Loop diuretics are not recommended in current hypertension guidelines largely due to the lack of outcome data. Nevertheless, they have been shown to lower blood pressure and to offer potential advantages over thiazide-type diuretics. Torsemide offers advantages of longer duration of action and once daily dosing (vs. furosemide and bumetanide) and more reliable bioavailability (vs. furosemide). Studies show that the previously employed high doses of thiazide-type diuretics lower BP more than furosemide. Loop diuretics appear to have a preferable side effect profile (less hyponatremia, hypokalemia, and possibly less glucose intolerance). Studies comparing efficacy and side effect profiles of loop diuretics with the lower, currently widely prescribed, thiazide doses are needed. Research is needed to fill gaps in knowledge and common misconceptions about loop diuretic use in hypertension and to determine their rightful place in the antihypertensive arsenal.
The multidriver: A reliable multicast service using the Xpress Transfer Protocol
NASA Technical Reports Server (NTRS)
Dempsey, Bert J.; Fenton, John C.; Weaver, Alfred C.
1990-01-01
A reliable multicast facility extends traditional point-to-point virtual circuit reliability to one-to-many communication. Such services can provide more efficient use of network resources, a powerful distributed name binding capability, and reduced latency in multidestination message delivery. These benefits will be especially valuable in real-time environments where reliable multicast can enable new applications and increase the availability and the reliability of data and services. We present a unique multicast service that exploits features in the next-generation, real-time transfer layer protocol, the Xpress Transfer Protocol (XTP). In its reliable mode, the service offers error, flow, and rate-controlled multidestination delivery of arbitrary-sized messages, with provision for the coordination of reliable reverse channels. Performance measurements on a single-segment Proteon ProNET-4 4 Mbps 802.5 token ring with heterogeneous nodes are discussed.
NASA Technical Reports Server (NTRS)
Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Bavuso, Salvatore J.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. The Hybrid Automated Reliability Predictor (HARP) tutorial provides insight into HARP modeling techniques and the interactive textual prompting input language via a step-by-step explanation and demonstration of HARP's fault occurrence/repair model and the fault/error handling models. Example applications are worked in their entirety and the HARP tabular output data are presented for each. Simple models are presented at first with each succeeding example demonstrating greater modeling power and complexity. This document is not intended to present the theoretical and mathematical basis for HARP.
Luo, X; Huang, M; He, D; Wang, M; Zhang, Y; Jiang, P
2018-05-29
High electrical conductivity and the exposure to more active sites are crucial to boost the performance of a glucose sensor. A porous binary metal oxide nanoarray integrated on a binder-free 3D electrode is expected to offer a highly sensitive sensing platform. As a model, porous NiCo2O4 nanowire arrays supported on carbon cloth (NiCo2O4 NWA/CC) have been prepared and used for enzyme-free glucose sensing. NiCo2O4 NWA/CC shows larger effective surface area, superior electronic conductivity, and higher catalytic activity towards enzyme-free glucose sensing, with a linear range from 1 μM to 0.63 mM, a sensitivity of 4.12 mA mM-1 cm-2, and low detection limit of 0.5 μM. Moreover, NiCo2O4 NWA/CC also displays good selectivity and stability and thus, it can be reliable for glucose detection in human serum samples. These findings inspire the fabrication of a high-performance electrochemical sensing platform by preparing porous binary metal oxide nanoarrays supported on a 3D conductive substrate.
NASA Astrophysics Data System (ADS)
Schröder, Daniel
2017-04-01
In the recent years an increasing awareness of geodetic measurement systems and their application for monitoring projects is clearly visible. With geodetic sensors it is possible to detect safety-related changes at monitoring objects with high temporal density, high accuracy and in a very reliable manner. Quality acquisitions, processing and storage of monitoring data as well as a professional on-site implementation are the most important requirements and challenges to contemporary systems in civil engineering, mining as well as oil and gas production. Monitoring measures provide important input for early warning, alarm, protection and verification of potential hazardous environments and therefore the risk management applied to projects have a significant influence. The implementation has to follow an optimization process incorporating necessary accuracy, reliability and economic efficiency. From the economical point of view the costs per observation point are crucial for most monitoring projects. Keeping in mind that the costs of classical high-end GNSS stations with a geodetic dual-frequency receiver is within the range of several 10,000 euro. Large monitoring networks with a high number of simultaneously observed points are very expensive and therefore eventually have to be cut back, substituted by compromising methods or totally withdrawn. A further development in the area of GNSS receivers could reduce this disadvantage. Within the last few years single-frequency receivers that record L1-signals of GPS/GLONASS and offer sub-centimeter positioning accuracies are increasingly offered on the market. The accuracy of GNSS measurements depends on many factors as the hardware itself as well as on external influences related to the measurement principals. The external influences can be strongly reduced or eliminated by appropriate measuring and processing methods. For a reliable monitoring system it is necessary that the results are comparable and consistent for each epoch. Based on these requirements DMT has developed the new DMT SAFEGUARD GNSS. In this article the latest developments in the field of low-cost GNSS are shown by different examples from industry and authorities. By means of a detailed accuracy study the DMT SAFEGUARD GNSS system applicability will be demonstrated. The study shows possibilities to detect coordinate shifts on sub centimeter level by using suitable data processing approaches and permanent network solutions. In addition to the DMT SAFEGUARD GNSS system this article illustrates the combination with further relevant sensors to integrated multisensorial networks. Such networks include geodetic data, geophysical data, geotechnical data, video, audio etc. For the central integration of all sensor types DMT has developed a web-based monitoring system - DMT SAFEGUARD which offers individual customizing, sophisticated analysis tools as well as comprehensive reporting options.
Ventura, Joseph; Cienfuegos, Angel; Boxer, Oren; Bilder, Robert
2008-11-01
Cognitive deficits are core features of schizophrenia that have been associated reliably with functional outcomes and now are a focus of treatment research. New rating scales are needed to complement current psychometric testing procedures, both to enable wider clinical use, and to serve as endpoints in clinical trials. Subjects were 35 schizophrenia patient-and-caregiver pairs recruited from the UCLA and West Los Angeles VA Outpatient Psychiatry Departments. Participants were assessed with the Clinical Global Impression of Cognition in Schizophrenia (CGI-CogS), an interview-based rating scale of cognitive functioning, on 3 occasions (baseline, 1 month, and 3 months). A computerized neurocognitive battery (Cogtest), an assessment of functioning, and symptom measures were administered at two occasions (baseline and one month). The CGI-CogS ratings generally showed a high level of internal consistency (Cronbach's alpha=.69 to .96), adequate levels of inter-rater reliability (ICC's=.71 to .80), and high test-retest stability (ICC's=.92 to .95). Correlations of caregiver and rater global (but not "patient only rating") CGI-CogS ratings with neurocognitive performance were in the moderate range (r's=-.27 to -.48), while most of the correlations with functional outcome were moderate to high (r's=-.41 to -.72). In fact, the CGI-CogS ratings were significantly more correlated with Social Functioning than were objective neurocognitive test scores (p=.02) and showed a trend in the same direction for predicting Instrumental Functioning (p=.06). We found moderate correlations between CGI-CogS global ratings and PANSS positive (r's=.36 to .49) and SANS negative symptoms (r=.41 to .61), but not with BPRS depression (r's=.11 to .13). An interview-based measure of cognition demonstrated high internal consistency, good inter-rater reliability, and high test-retest reliability. Caregiver ratings appear to add important clinical information over patient-only ratings. The CGI-CogS showed moderate validity with respect to neurocognitive performance and functional outcome, and correlations of CGI-CogS with functional outcomes were stronger than correlations of objective neurocognitive performance with functional outcomes. The CGI-CogS appears to offer a reliable and valid method for clinical rating of cognitive deficits and their impact on everyday functioning in schizophrenia.
Wade, Kimberley A; Nash, Robert A; Lindsay, D Stephen
2018-05-01
Wixted, Mickes, and Fisher (this issue) take issue with the common trope that eyewitness memory is inherently unreliable. They draw on a large body of mock-crime research and a small number of field studies, which indicate that high-confidence eyewitness reports are usually accurate, at least when memory is uncontaminated and suitable interviewing procedures are used. We agree with the thrust of Wixted et al.'s argument and welcome their invitation to confront the mass underselling of eyewitnesses' potential reliability. Nevertheless, we argue that there is a comparable risk of overselling eyewitnesses' reliability. Wixted et al.'s reasoning implies that near-pristine conditions or uncontaminated memories are normative, but there are at least two good reasons to doubt this. First, psychological science does not yet offer a good understanding of how often and when eyewitness interviews might deviate from best practice in ways that compromise the accuracy of witnesses' reports. Second, witnesses may frequently be exposed to preinterview influences that could corrupt reports obtained in best-practice interviews.
A knowledge-based system with learning for computer communication network design
NASA Technical Reports Server (NTRS)
Pierre, Samuel; Hoang, Hai Hoc; Tropper-Hausen, Evelyne
1990-01-01
Computer communication network design is well-known as complex and hard. For that reason, the most effective methods used to solve it are heuristic. Weaknesses of these techniques are listed and a new approach based on artificial intelligence for solving this problem is presented. This approach is particularly recommended for large packet switched communication networks, in the sense that it permits a high degree of reliability and offers a very flexible environment dealing with many relevant design parameters such as link cost, link capacity, and message delay.
Investigation of fast initialization of spacecraft bubble memory systems
NASA Technical Reports Server (NTRS)
Looney, K. T.; Nichols, C. D.; Hayes, P. J.
1984-01-01
Bubble domain technology offers significant improvement in reliability and functionality for spacecraft onboard memory applications. In considering potential memory systems organizations, minimization of power in high capacity bubble memory systems necessitates the activation of only the desired portions of the memory. In power strobing arbitrary memory segments, a capability of fast turn on is required. Bubble device architectures, which provide redundant loop coding in the bubble devices, limit the initialization speed. Alternate initialization techniques are investigated to overcome this design limitation. An initialization technique using a small amount of external storage is demonstrated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Been, J.
1999-07-01
Ti-5Al-1Sn-1Zr-1V-O.8M0 is a near alpha titanium alloy of intermediate strength, designed for high toughness, good weldability, stress-corrosion cracking resistance, and room temperature creep resistance. Ideally suited for marine environments, Ti 5111 offers the means to aid the navy in fulfilling their goals of reducing maintenance and life cycle costs, reducing topside and overall weight, improve survivability and increase reliability. The alloy was recently included in the ASTM bar and plate specifications as ASTM Grade 32.
Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)
NASA Technical Reports Server (NTRS)
Ghaffaroam. Reza
2014-01-01
Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.
NASA Astrophysics Data System (ADS)
Fan, Yingmin; Wang, Jingwei; Cai, Lei; Mitra, Thomas; Hauschild, Dirk; Zah, Chung-En; Liu, Xingsheng
2018-02-01
High power diode lasers (HPDLs) offer the highest wall-plug efficiency, highest specific power (power-to-weight ratio), arguably the lowest cost and highest reliability among all laser types. However, the poor beam quality of commercially HPDLs is the main bottleneck limiting their direct applications requiring high brightness at least in one dimension. In order to expand the applications of HPDLs, beam shaping and optical design are essential. In this work, we report the recent progresses on maximizing applications of HPDLs by synergizing diode laser light source and beam shaping micro-optics. Successful examples of matching of diode laser light sources and beam shaping micro-optics driving new applications are presented.
Electrocatalysts by atomic layer deposition for fuel cell applications
Cheng, Niancai; Shao, Yuyan; Liu, Jun; ...
2016-01-22
Here, fuel cells are a promising technology solution for reliable and clean energy because they offer high energy conversion efficiency and low emission of pollutants. However, high cost and insufficient durability are considerable challenges for widespread adoption of polymer electrolyte membrane fuel cells (PEMFCs) in practical applications. Current PEMFCs catalysts have been identified as major contributors to both the high cost and limited durability. Atomic layer deposition (ALD) is emerging as a powerful technique for solving these problems due to its exclusive advantages over other methods. In this review, we summarize recent developments of ALD in PEMFCs with a focusmore » on design of materials for improved catalyst activity and durability. New research directions and future trends have also been discussed.« less
Double high refractive-index contrast grating VCSEL
NASA Astrophysics Data System (ADS)
Gebski, Marcin; Dems, Maciej; Wasiak, Michał; Sarzała, Robert P.; Lott, J. A.; Czyszanowski, Tomasz
2015-03-01
Distributed Bragg reflectors (DBRs) are typically used as the highly reflecting mirrors of vertical-cavity surface-emitting lasers (VCSELs). In order to provide optical field confinement, oxide apertures are often incorporated in the process of the selective wet oxidation of high aluminum-content DBR layers. This technology has some potential drawbacks such as difficulty in controlling the uniformity of the oxide aperture diameters across a large-diameter (≥ 6 inch) production wafers, high DBR series resistance especially for small diameters below about 5 μm despite elaborate grading and doping schemes, free carrier absorption at longer emission wavelengths in the p-doped DBRs, reduced reliability for oxide apertures placed close to the quantum wells, and low thermal conductivity for transporting heat away from the active region. A prospective alternative mirror is a high refractive index contrast grating (HCG) monolithically integrated with the VCSEL cavity. Two HCG mirrors potentially offer a very compact and simplified VCSEL design although the problems of resistance, heat dissipation, and reliability are not completely solved. We present an analysis of a double HCG 980 nm GaAs-based ultra-thin VCSEL. We analyze the optical confinement of such a structure with a total optical thickness is ~1.0λ including the optical cavity and the two opposing and parallel HCG mirrors.
Proven high-reliability assembly methods applied to avionics fiber-optics high-speed transceivers
NASA Astrophysics Data System (ADS)
Lauzon, Jocelyn; Leduc, Lorrain; Bessette, Daniel; Bélanger, Nicolas; Larose, Robert; Dion, Bruno
2012-06-01
Harsh environment avionics applications require operating temperature ranges that can extend to, and exceed -50 to 115°C. For obvious maintenance, management and cost arguments, product lifetimes as long as 20 years are also sought. This leads to mandatory long-term hermeticity that cannot be obtained with epoxy or silicone sealing; but only with glass seal or metal solder or brazing. A hermetic design can indirectly result in the required RF shielding of the component. For fiber-optics products, these specifications need to be compatible with the smallest possible size, weight and power consumption. The products also need to offer the best possible high-speed performances added to the known EMI immunity in the transmission lines. Fiber-optics transceivers with data rates per fiber channel up to 10Gbps are now starting to be offered on the market for avionics applications. Some of them are being developed by companies involved in the "normal environment" telecommunications market that are trying to ruggedize their products packaging in order to diversify their customer base. Another approach, for which we will present detailed results, is to go back to the drawing boards and design a new product that is adapted to proven MIL-PRF-38534 high-reliability packaging assembly methods. These methods will lead to the introduction of additional requirements at the components level; such as long-term high-temperature resistance for the fiber-optic cables. We will compare both approaches and demonstrate the latter, associated with the redesign, is the preferable one. The performance of the fiber-optic transceiver we have developed, in terms of qualification tests such as temperature cycling, constant acceleration, hermeticity, residual gaz analysis, operation under random vibration and mechanical shocks and accelerated lifetime tests will be presented. The tests are still under way, but so far, we have observed no performance degradation of such a product after more than 1050 hours of operation at 95°C.
ERIC Educational Resources Information Center
Hartley, S. L.; MacLean, W. E., Jr.
2006-01-01
Background: Likert-type scales are increasingly being used among people with intellectual disability (ID). These scales offer an efficient method for capturing a wide range of variance in self-reported attitudes and behaviours. This review is an attempt to evaluate the reliability and validity of Likert-type scales in people with ID. Methods:…
Bennett, R J; Jayakody, D M P; Eikelboom, R H; Taljaard, D S; Atlas, M D
2016-02-01
To investigate the ability of cochlear implant (CI) recipients to physically handle and care for their hearing implant device(s) and to identify factors that may influence skills. To assess device management skills, a clinical survey was developed and validated on a clinical cohort of CI recipients. Survey development and validation. A prospective convenience cohort design study. Specialist hearing implant clinic. Forty-nine post-lingually deafened, adult CI recipients, at least 12 months postoperative. Survey test-retest reliability, interobserver reliability and responsiveness. Correlations between management skills and participant demographic, audiometric, clinical outcomes and device factors. The Cochlear Implant Management Skills survey was developed, demonstrating high test-retest reliability (0.878), interobserver reliability (0.972) and responsiveness to intervention (skills training) [t(20) = -3.913, P = 0.001]. Cochlear Implant Management Skills survey scores range from 54.69% to 100% (mean: 83.45%, sd: 12.47). No associations were found between handling skills and participant factors. This is the first study to demonstrate a range in cochlear implant device handling skills in CI recipients and offers clinicians and researchers a tool to systematically and objectively identify shortcomings in CI recipients' device handling skills. © 2015 John Wiley & Sons Ltd.
Rapid Prototyping of Slot Die Devices for Roll to Roll Production of EL Fibers
Bellingham, Alyssa; Bromhead, Nicholas; Fontecchio, Adam
2017-01-01
There is a growing interest in fibers supporting optoelectrical properties for textile and wearable display applications. Solution-processed electroluminescent (EL) material systems can be continuously deposited onto fiber or yarn substrates in a roll-to-roll process, making it easy to scale manufacturing. It is important to have precise control over layer deposition to achieve uniform and reliable light emission from these EL fibers. Slot-die coating offers this control and increases the rate of EL fiber production. Here, we report a highly adaptable, cost-effective 3D printing model for developing slot dies used in automatic coating systems. The resulting slot-die coating system enables rapid, reliable production of alternating current powder-based EL (ACPEL) fibers and can be adapted for many material systems. The benefits of this system over dip-coating for roll-to-roll production of EL fibers are demonstrated in this work. PMID:28772954
Application of IUS equipment and experience to orbit transfer vehicles of the 90's
NASA Astrophysics Data System (ADS)
Bangsund, E.; Keeney, J.; Cowgill, E.
1985-10-01
This paper relates experiences with the IUS program and the application of that experience to Future Orbit Transfer Vehicles. More specifically it includes the implementation of the U.S. Air Force Space Division high reliability parts standard (SMASO STD 73-2C) and the component/system test standard (MIL-STD-1540A). Test results from the parts and component level testing and the resulting system level test program for fourteen IUS flight vehicles are discussed. The IUS program has had the highest compliance with these standards and thus offers a benchmark of experience for future programs demanding extreme reliability. In summary, application of the stringent parts standard has resulted in fewer failures during testing and the stringent test standard has eliminated design problems in the hardware. Both have been expensive in costs and schedules, and should be applied with flexibility.
Application of exercise ECG stress test in the current high cost modern-era healthcare system.
Vaidya, Gaurang Nandkishor
Exercise electrocardiogram (ECG) tests boasts of being more widely available, less resource intensive, lower cost and absence of radiation. In the presence of a normal baseline ECG, an exercise ECG test is able to generate a reliable and reproducible result almost comparable to Technitium-99m sestamibi perfusion imaging. Exercise ECG changes when combined with other clinical parameters obtained during the test has the potential to allow effective redistribution of scarce resources by excluding low risk patients with significant accuracy. As we look towards a future of rising healthcare costs, increased prevalence of cardiovascular disease and the need for proper allocation of limited resources; exercise ECG test offers low cost, vital and reliable disease interpretation. This article highlights the physiology of the exercise ECG test, patient selection, effective interpretation, describe previously reported scores and their clinical application in today's clinical practice. Copyright © 2017. Published by Elsevier B.V.
Lithium-Ion Technology for Aerospace Applications- Advancing Battery Management Electronics
NASA Astrophysics Data System (ADS)
Gitzendanner, R.; Jones, E.; Deory, C.; Carmen, D.
2005-05-01
Lithium-ion technology offers a unique, weight and volume saving, solution to the power storage needs of space applications. With higher energy and power densities than conventional technologies, such as Nickel-Hydrogen (Ni-H) and Nickel/Cadmium (Ni- Cd), and comparable cycle life and reliability, Lithium-ion technology is gaining interest in many space applications. As the demand for Lithium-ion batteries with high reliability and long life increases, the need for battery management electronics, including individual cell balancing and monitoring, becomes apparent. With onboard electronics, the cells are monitored individually, and are protected from over charge or over discharge by way of integral protection circuitry. State of Charge, State of Health and other useful telemetry can also be calculated by the integrated electronics and reported to the application. Lab-based, and real-life, testing and use of these battery systems has shown the advantages of an integrated electronics package.
Performance and Reliability of Bonded Interfaces for High-Temperature Packaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paret, Paul P
2017-08-02
Sintered silver has proven to be a promising candidate for use as a die-attach and substrate-attach material in automotive power electronics components. It holds promise of greater reliability than lead-based and lead-free solders, especially at higher temperatures (>200 degrees C). Accurate predictive lifetime models of sintered silver need to be developed and its failure mechanisms thoroughly characterized before it can be deployed as a die-attach or substrate-attach material in wide-bandgap device-based packages. Mechanical characterization tests that result in stress-strain curves and accelerated tests that produce cycles-to-failure result will be conducted. Also, we present a finite element method (FEM) modeling methodologymore » that can offer greater accuracy in predicting the failure of sintered silver under accelerated thermal cycling. A fracture mechanics-based approach is adopted in the FEM model, and J-integral/thermal cycle values are computed.« less
Rapid Prototyping of Slot Die Devices for Roll to Roll Production of EL Fibers.
Bellingham, Alyssa; Bromhead, Nicholas; Fontecchio, Adam
2017-05-29
There is a growing interest in fibers supporting optoelectrical properties for textile and wearable display applications. Solution-processed electroluminescent (EL) material systems can be continuously deposited onto fiber or yarn substrates in a roll-to-roll process, making it easy to scale manufacturing. It is important to have precise control over layer deposition to achieve uniform and reliable light emission from these EL fibers. Slot-die coating offers this control and increases the rate of EL fiber production. Here, we report a highly adaptable, cost-effective 3D printing model for developing slot dies used in automatic coating systems. The resulting slot-die coating system enables rapid, reliable production of alternating current powder-based EL (ACPEL) fibers and can be adapted for many material systems. The benefits of this system over dip-coating for roll-to-roll production of EL fibers are demonstrated in this work.
Pye, Kenneth; Blott, Simon J
2004-08-11
Particle size is a fundamental property of any sediment, soil or dust deposit which can provide important clues to nature and provenance. For forensic work, the particle size distribution of sometimes very small samples requires precise determination using a rapid and reliable method with a high resolution. The Coulter trade mark LS230 laser granulometer offers rapid and accurate sizing of particles in the range 0.04-2000 microm for a variety of sample types, including soils, unconsolidated sediments, dusts, powders and other particulate materials. Reliable results are possible for sample weights of just 50 mg. Discrimination between samples is performed on the basis of the shape of the particle size curves and statistical measures of the size distributions. In routine forensic work laser granulometry data can rarely be used in isolation and should be considered in combination with results from other techniques to reach an overall conclusion.
Highly Stretchable Conductors Based on Expanded Graphite Macroconfined in Tubular Rubber.
Luo, Wei; Wu, Tongfei; Chen, Biqiong; Liang, Mei; Zou, Huawei
2017-12-13
Highly stretchable and durable conductors are significant to the development of wearable devices, robots, human-machine interfaces, and other artificial intelligence products. Although many respectable methods have been reported, it is still a challenge to fabricate stretchable conductors with a large elastic limit, high conductivity, and excellent reliability in rapid, effective, and economic ways. Herein, a facile method is offered to fabricate high-performance stretchable tubular conductors (TCs) based on a macroconfined structure of expanded graphite (EG) in rubber tubing by simply physical packing. The maximum original electrical conductivity of TCs reached a high value of 160.6 S/cm. Meanwhile, TCs showed more insensitive response of conductivity to increasing tensile strain compared to the TCs encapsulated with liquid metal or ionic liquid. The conductivity and effective stretchability of TCs can be adjusted by varying the packing density of EG. A low gauge factor below 3 was reached even under 400% stretching for TCs with a packing density of 1.233 g/cm 3 . The excellent resilience and good stability of conductivity of TCs during dynamic stretching-releasing cycles are attributed to the stable and rapid reconstruction of the percolation network of EG particles. The combination of high conductivity, tunable stretchability, and good reliability renders potential applications to TCs, such as highly stretchable interconnects or strain sensors, in human motion detection.
[Myocardial viability: update in nuclear cardiology].
Vallejo, Enrique
2007-01-01
Evaluation of myocardial viability with the aid of radionuclides, is a technique that offers reliable, reproducible information, with an attractive cost-benefit relationship, in the study of the myocardial viability, integrating cardiac molecular, metabolic, and functional aspects. Nowadays, coronary risk stratification in post-myocardial infarction patients pretends to locate them as low-, intermediate, and high risk-subjects that can suffer cardiovascular complications in the very near future. Low-risk patients are characterized by a cardiac-related mortality below 1%, whereas high-risk mortality is greater than 3%. Because of clinical complications following a myocardial infarction are observed during the first month of evolution, clinical guidelines suggest to evaluate the cardiovascular risk before hospital discharge.
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
Takamatsu, Seiichi; Lonjaret, Thomas; Crisp, Dakota; Badier, Jean-Michel; Malliaras, George G.; Ismailova, Esma
2015-01-01
Wearable sensors are receiving a great deal of attention as they offer the potential to become a key technological tool for healthcare. In order for this potential to come to fruition, new electroactive materials endowing high performance need to be integrated with textiles. Here we present a simple and reliable technique that allows the patterning of conducting polymers on textiles. Electrodes fabricated using this technique showed a low impedance contact with human skin, were able to record high quality electrocardiograms at rest, and determine heart rate even when the wearer was in motion. This work paves the way towards imperceptible electrophysiology sensors for human health monitoring. PMID:26446346
Explosion Clad for Upstream Oil and Gas Equipment
NASA Astrophysics Data System (ADS)
Banker, John G.; Massarello, Jack; Pauly, Stephane
2011-01-01
Today's upstream oil and gas facilities frequently involve the combination of high pressures, high temperatures, and highly corrosive environments, requiring equipment that is thick wall, corrosion resistant, and cost effective. When significant concentrations of CO2 and/or H2S and/or chlorides are present, corrosion resistant alloys (CRA) can become the material of choice for separator equipment, piping, related components, and line pipe. They can provide reliable resistance to both corrosion and hydrogen embrittlement. For these applications, the more commonly used CRA's are 316L, 317L and duplex stainless steels, alloy 825 and alloy 625, dependent upon the application and the severity of the environment. Titanium is also an exceptional choice from the technical perspective, but is less commonly used except for heat exchangers. Explosion clad offers significant savings by providing a relatively thin corrosion resistant alloy on the surface metallurgically bonded to a thick, lower cost, steel substrate for the pressure containment. Developed and industrialized in the 1960's the explosion cladding technology can be used for cladding the more commonly used nickel based and stainless steel CRA's as well as titanium. It has many years of proven experience as a reliable and highly robust clad manufacturing process. The unique cold welding characteristics of explosion cladding reduce problems of alloy sensitization and dissimilar metal incompatibility. Explosion clad materials have been used extensively in both upstream and downstream oil, gas and petrochemical facilities for well over 40 years. The explosion clad equipment has demonstrated excellent resistance to corrosion, embrittlement and disbonding. Factors critical to insure reliable clad manufacture and equipment design and fabrication are addressed.
The High-Superior-Tension Technique: Evolution of Lipoabdominoplasty
Pascal, Jean Francois
2010-01-01
Because abdominoplasty is associated with complications such as seroma and necrosis as well as epigastric bulging and a suprapubic scar located too high, the demand for this procedure is not as high as it otherwise might be. However, although these negative effects were common many years ago, their incidence has decreased dramatically with modern abdominoplastic techniques. One approach using a combination of abdominoplasty and liposuction or lipoabdominoplasty has resolved many of the problems faced with earlier techniques, offering aesthetically pleasing results and excellent reliability. The keys to successful lipoabdominoplasty, first developed as the high-superior-tension technique, are extensive liposuction, preservation of lymphatic trunks, preaponeurotic epigastric dissection, major muscle fascia plication, two high-tension paraumbilical sutures, hypogastric tension sutures, and closure of the dead spaces. The most recent updates to this technique are described in this article. PMID:20931193
Present status and future prospects of heavy ion beams as drivers for ICF
NASA Astrophysics Data System (ADS)
Godlove, Terry F.
1986-01-01
A candidate driver for a practical inertial fusion reactor system must, among other characteristics, be cost effective and reliable for the parameters required by the fusion target and the remainder of the system. Although the history of large particle accelerators provides abundant evidence of their reliability at high repetition rates, their capital cost for the fusion application has been open to question. Attempts to design cost effective systems began with accelerators based on currently available technology such as RF linacs and storage rings. The West German HIBALL and the Japanese HIBLIC are examples of this initial effort. These designs are sufficiently credible that a strong argument can be made for the heavy ion method in general, but to reduce the cost per unit power it was found necessary to design for large scale, hence high capital cost. Emphasis in the U.S. shifted to newer technologies which offer hope of significant improvement in cost. In this paper the status of various heavy ion driver designs are compared with currently perceived requirements in order to illustrate their potential and assess their development needs.
Software reliability experiments data analysis and investigation
NASA Technical Reports Server (NTRS)
Walker, J. Leslie; Caglayan, Alper K.
1991-01-01
The objectives are to investigate the fundamental reasons which cause independently developed software programs to fail dependently, and to examine fault tolerant software structures which maximize reliability gain in the presence of such dependent failure behavior. The authors used 20 redundant programs from a software reliability experiment to analyze the software errors causing coincident failures, to compare the reliability of N-version and recovery block structures composed of these programs, and to examine the impact of diversity on software reliability using subpopulations of these programs. The results indicate that both conceptually related and unrelated errors can cause coincident failures and that recovery block structures offer more reliability gain than N-version structures if acceptance checks that fail independently from the software components are available. The authors present a theory of general program checkers that have potential application for acceptance tests.
The reliability paradox: Why robust cognitive tasks do not produce reliable individual differences.
Hedge, Craig; Powell, Georgina; Sumner, Petroc
2018-06-01
Individual differences in cognitive paradigms are increasingly employed to relate cognition to brain structure, chemistry, and function. However, such efforts are often unfruitful, even with the most well established tasks. Here we offer an explanation for failures in the application of robust cognitive paradigms to the study of individual differences. Experimental effects become well established - and thus those tasks become popular - when between-subject variability is low. However, low between-subject variability causes low reliability for individual differences, destroying replicable correlations with other factors and potentially undermining published conclusions drawn from correlational relationships. Though these statistical issues have a long history in psychology, they are widely overlooked in cognitive psychology and neuroscience today. In three studies, we assessed test-retest reliability of seven classic tasks: Eriksen Flanker, Stroop, stop-signal, go/no-go, Posner cueing, Navon, and Spatial-Numerical Association of Response Code (SNARC). Reliabilities ranged from 0 to .82, being surprisingly low for most tasks given their common use. As we predicted, this emerged from low variance between individuals rather than high measurement variance. In other words, the very reason such tasks produce robust and easily replicable experimental effects - low between-participant variability - makes their use as correlational tools problematic. We demonstrate that taking such reliability estimates into account has the potential to qualitatively change theoretical conclusions. The implications of our findings are that well-established approaches in experimental psychology and neuropsychology may not directly translate to the study of individual differences in brain structure, chemistry, and function, and alternative metrics may be required.
Insightful practice: a reliable measure for medical revalidation
Guthrie, Bruce; Sullivan, Frank M; Mercer, Stewart W; Russell, Andrew; Bruce, David A
2012-01-01
Background Medical revalidation decisions need to be reliable if they are to reassure on the quality and safety of professional practice. This study tested an innovative method in which general practitioners (GPs) were assessed on their reflection and response to a set of externally specified feedback. Setting and participants 60 GPs and 12 GP appraisers in the Tayside region of Scotland, UK. Methods A feedback dataset was specified as (1) GP-specific data collected by GPs themselves (patient and colleague opinion; open book self-evaluated knowledge test; complaints) and (2) Externally collected practice-level data provided to GPs (clinical quality and prescribing safety). GPs' perceptions of whether the feedback covered UK General Medical Council specified attributes of a ‘good doctor’ were examined using a mapping exercise. GPs' professionalism was examined in terms of appraiser assessment of GPs' level of insightful practice, defined as: engagement with, insight into and appropriate action on feedback data. The reliability of assessment of insightful practice and subsequent recommendations on GPs' revalidation by face-to-face and anonymous assessors were investigated using Generalisability G-theory. Main outcome measures Coverage of General Medical Council attributes by specified feedback and reliability of assessor recommendations on doctors' suitability for revalidation. Results Face-to-face assessment proved unreliable. Anonymous global assessment by three appraisers of insightful practice was highly reliable (G=0.85), as were revalidation decisions using four anonymous assessors (G=0.83). Conclusions Unlike face-to-face appraisal, anonymous assessment of insightful practice offers a valid and reliable method to decide GP revalidation. Further validity studies are needed. PMID:22653078
Reliability of Eustachian tube function measurements in a hypobaric and hyperbaric pressure chamber.
Meyer, M F; Jansen, S; Mordkovich, O; Hüttenbrink, K-B; Beutner, D
2017-12-01
Measurement of the Eustachian tube (ET) function is a challenge. The demand for a precise and meaningful diagnostic tool increases-especially because more and more operative therapies are being offered without objective evidence. The measurement of the ET function by continuous impedance recording in a pressure chamber is an established method, although the reliability of the measurements is still unclear. Twenty-five participants (50 ears) were exposed to phases of compression and decompression in a hypo- and hyperbaric pressure chamber. The ET function reflecting parameters-ET opening pressure (ETOP), ET opening duration (ETOD) and ET opening frequency (ETOF)-were determined under exactly the same preconditions three times in a row. The intraclass correlation coefficient (ICC) and Bland and Altman plot were used to assess test-retest reliability. ICCs revealed a high correlation for ETOP and ETOF in phases of decompression (passive equalisation) as well as ETOD and ETOP in phases of compression (active induced equalisation). Very high correlation could be shown for ETOD in decompression and ETOF in compression phases. The Bland and Altman graphs could show that measurements provide results within a 95 % confidence interval in compression and decompression phases. We conclude that measurements in a pressure chamber are a very valuable tool in terms of estimating the ET opening and closing function. Measurements show some variance comparing participants, but provide reliable results within a 95 % confidence interval in retest. This study is the basis for enabling efficacy measurements of ET treatment modalities. © 2017 John Wiley & Sons Ltd.
Ka-band MMIC subarray technology program (Ka-Mist)
NASA Technical Reports Server (NTRS)
Pottenger, Warren
1995-01-01
The broad objective of this program was to demonstrate a proof of concept insertion of Monolithic Microwave Integrated Circuit (MMIC) device technology into an innovative (tile architecture) active phased array antenna application supporting advanced EHF communication systems. Ka-band MMIC arrays have long been considered as having high potential for increasing the capability of space, aircraft, and land mobile communication systems in terms of scan performance, data rate, link margin, and flexibility while offering a significant reduction in size, weight, and power consumption. Insertion of MMIC technology into antenna systems, particularly at millimeter wave frequencies using low power and low noise amplifiers in close proximity to the radiating elements, offers a significant improvement in the array transmit efficiency, receive system noise figure, and overall array reliability. Application of active array technology also leads to the use of advanced beamforming techniques that can improve beam agility, diversity, and adaptivity to complex signal environments.
Monolithic Microwave Integrated Circuit (MMIC) technology for space communications applications
NASA Technical Reports Server (NTRS)
Connolly, Denis J.; Bhasin, Kul B.; Romanofsky, Robert R.
1987-01-01
Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMIC's to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMIC's is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. For the more distant future pseudomorphic indium gallium arsenide (InGaAs) and other advanced III-V materials offer the possibility of MMIC subsystems well up into the millimeter wavelength region. All of these technology elements are in NASA's MMIC program. Their status is reviewed.
Monolithic Microwave Integrated Circuit (MMIC) technology for space communications applications
NASA Technical Reports Server (NTRS)
Connolly, Denis J.; Bhasin, Kul B.; Romanofsky, Robert R.
1987-01-01
Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMICs to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMICs is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. For the more distant future pseudomorphic indium gallium arsenide (InGaAs) and other advanced III-V materials offer the possibility of MMIC subsystems well up into the millimeter wavelength region. All of these technology elements are in NASA's MMIC program. Their status is reviewed.
Realistic Specific Power Expectations for Advanced Radioisotope Power Systems
NASA Technical Reports Server (NTRS)
Mason, Lee S.
2006-01-01
Radioisotope Power Systems (RPS) are being considered for a wide range of future NASA space science and exploration missions. Generally, RPS offer the advantages of high reliability, long life, and predictable power production regardless of operating environment. Previous RPS, in the form of Radioisotope Thermoelectric Generators (RTG), have been used successfully on many NASA missions including Apollo, Viking, Voyager, and Galileo. NASA is currently evaluating design options for the next generation of RPS. Of particular interest is the use of advanced, higher efficiency power conversion to replace the previous thermoelectric devices. Higher efficiency reduces the quantity of radioisotope fuel and potentially improves the RPS specific power (watts per kilogram). Power conversion options include Segmented Thermoelectric (STE), Stirling, Brayton, and Thermophotovoltaic (TPV). This paper offers an analysis of the advanced 100 watt-class RPS options and provides credible projections for specific power. Based on the analysis presented, RPS specific power values greater than 10 W/kg appear unlikely.
Metastable Metal Hydrides for Hydrogen Storage
Graetz, Jason
2012-01-01
The possibility of using hydrogen as a reliable energy carrier for both stationary and mobile applications has gained renewed interest in recent years due to improvements in high temperature fuel cells and a reduction in hydrogen production costs. However, a number of challenges remain and new media are needed that are capable of safely storing hydrogen with high gravimetric and volumetric densities. Metal hydrides and complex metal hydrides offer some hope of overcoming these challenges; however, many of the high capacity “reversible” hydrides exhibit a large endothermic decomposition enthalpy making it difficult to release the hydrogen at low temperatures. Onmore » the other hand, the metastable hydrides are characterized by a low reaction enthalpy and a decomposition reaction that is thermodynamically favorable under ambient conditions. The rapid, low temperature hydrogen evolution rates that can be achieved with these materials offer much promise for mobile PEM fuel cell applications. However, a critical challenge exists to develop new methods to regenerate these hydrides directly from the reactants and hydrogen gas. This spotlight paper presents an overview of some of the metastable metal hydrides for hydrogen storage and a few new approaches being investigated to address the key challenges associated with these materials.« less
Development of the Assessment of Belief Conflict in Relationship-14 (ABCR-14).
Kyougoku, Makoto; Teraoka, Mutsumi; Masuda, Noriko; Ooura, Mariko; Abe, Yasushi
2015-01-01
Nurses and other healthcare workers frequently experience belief conflict, one of the most important, new stress-related problems in both academic and clinical fields. In this study, using a sample of 1,683 nursing practitioners, we developed The Assessment of Belief Conflict in Relationship-14 (ABCR-14), a new scale that assesses belief conflict in the healthcare field. Standard psychometric procedures were used to develop and test the scale, including a qualitative framework concept and item-pool development, item reduction, and scale development. We analyzed the psychometric properties of ABCR-14 according to entropy, polyserial correlation coefficient, exploratory factor analysis, confirmatory factor analysis, average variance extracted, Cronbach's alpha, Pearson product-moment correlation coefficient, and multidimensional item response theory (MIRT). The results of the analysis supported a three-factor model consisting of 14 items. The validity and reliability of ABCR-14 was suggested by evidence from high construct validity, structural validity, hypothesis testing, internal consistency reliability, and concurrent validity. The result of the MIRT offered strong support for good item response of item slope parameters and difficulty parameters. However, the ABCR-14 Likert scale might need to be explored from the MIRT point of view. Yet, as mentioned above, there is sufficient evidence to support that ABCR-14 has high validity and reliability. The ABCR-14 demonstrates good psychometric properties for nursing belief conflict. Further studies are recommended to confirm its application in clinical practice.
More Reliable Lithium-Sulfur Batteries: Status, Solutions and Prospects.
Fang, Ruopian; Zhao, Shiyong; Sun, Zhenhua; Wang, Da-Wei; Cheng, Hui-Ming; Li, Feng
2017-12-01
Lithium-sulfur (Li-S) batteries have attracted tremendous interest because of their high theoretical energy density and cost effectiveness. The target of Li-S battery research is to produce batteries with a high useful energy density that at least outperforms state-of-the-art lithium-ion batteries. However, due to an intrinsic gap between fundamental research and practical applications, the outstanding electrochemical results obtained in most Li-S battery studies indeed correspond to low useful energy densities and are not really suitable for practical requirements. The Li-S battery is a complex device and its useful energy density is determined by a number of design parameters, most of which are often ignored, leading to the failure to meet commercial requirements. The purpose of this review is to discuss how to pave the way for reliable Li-S batteries. First, the current research status of Li-S batteries is briefly reviewed based on statistical information obtained from literature. This includes an analysis of how the various parameters influence the useful energy density and a summary of existing problems in the current Li-S battery research. Possible solutions and some concerns regarding the construction of reliable Li-S batteries are comprehensively discussed. Finally, insights are offered on the future directions and prospects in Li-S battery field. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Microstructures define melting of molybdenum at high pressures
NASA Astrophysics Data System (ADS)
Hrubiak, Rostislav; Meng, Yue; Shen, Guoyin
2017-03-01
High-pressure melting anchors the phase diagram of a material, revealing the effect of pressure on the breakdown of the ordering of atoms in the solid. An important case is molybdenum, which has long been speculated to undergo an exceptionally steep increase in melting temperature when compressed. On the other hand, previous experiments showed nearly constant melting temperature as a function of pressure, in large discrepancy with theoretical expectations. Here we report a high-slope melting curve in molybdenum by synchrotron X-ray diffraction analysis of crystalline microstructures, generated by heating and subsequently rapidly quenching samples in a laser-heated diamond anvil cell. Distinct microstructural changes, observed at pressures up to 130 gigapascals, appear exclusively after melting, thus offering a reliable melting criterion. In addition, our study reveals a previously unsuspected transition in molybdenum at high pressure and high temperature, which yields highly textured body-centred cubic nanograins above a transition temperature.
Microstructures define melting of molybdenum at high pressures
Hrubiak, Rostislav; Meng, Yue; Shen, Guoyin
2017-01-01
High-pressure melting anchors the phase diagram of a material, revealing the effect of pressure on the breakdown of the ordering of atoms in the solid. An important case is molybdenum, which has long been speculated to undergo an exceptionally steep increase in melting temperature when compressed. On the other hand, previous experiments showed nearly constant melting temperature as a function of pressure, in large discrepancy with theoretical expectations. Here we report a high-slope melting curve in molybdenum by synchrotron X-ray diffraction analysis of crystalline microstructures, generated by heating and subsequently rapidly quenching samples in a laser-heated diamond anvil cell. Distinct microstructural changes, observed at pressures up to 130 gigapascals, appear exclusively after melting, thus offering a reliable melting criterion. In addition, our study reveals a previously unsuspected transition in molybdenum at high pressure and high temperature, which yields highly textured body-centred cubic nanograins above a transition temperature. PMID:28248309
Heat engine development for solar thermal power systems
NASA Technical Reports Server (NTRS)
Pham, H. Q.; Jaffe, L. D.
1981-01-01
The technical status of three heat engines (Stirling, high-temperature Brayton, and Combined cycle) for use in solar thermal power systems is presented. Performance goals necessary to develop a system competitive with conventional power requirements include an external heated engine output less than 40 kW, and efficiency power conversion subsystem at least 40% at rated output, and a half-power efficiency of at least 37%. Results show that the Stirling engine can offer a 39% efficiency with 100 hours of life, and a 20% efficiency with 10,000 hours of life, but problems with seals and heater heads exist. With a demonstrated efficiency near 31% at 1500 F and a minimum lifetime of 100,000 hours, the Brayton engine does not offer sufficient engine lifetime, efficiency, and maintenance for solar thermal power systems. Examination of the Rankine bottoming cycle of the Combined cycle engine reveals a 30 year lifetime, but a low efficiency. Additional development of engines for solar use is primarily in the areas of components to provide a long lifetime, high reliability, and low maintenance (no more than $0.001/kW-hr).
Schlehuber, Lisa D; McFadyen, Iain J; Shu, Yu; Carignan, James; Duprex, W Paul; Forsyth, William R; Ho, Jason H; Kitsos, Christine M; Lee, George Y; Levinson, Douglas A; Lucier, Sarah C; Moore, Christopher B; Nguyen, Niem T; Ramos, Josephine; Weinstock, B André; Zhang, Junhong; Monagle, Julie A; Gardner, Colin R; Alvarez, Juan C
2011-07-12
As a result of thermal instability, some live attenuated viral (LAV) vaccines lose substantial potency from the time of manufacture to the point of administration. Developing regions lacking extensive, reliable refrigeration ("cold-chain") infrastructure are particularly vulnerable to vaccine failure, which in turn increases the burden of disease. Development of a robust, infectivity-based high throughput screening process for identifying thermostable vaccine formulations offers significant promise for vaccine development across a wide variety of LAV products. Here we describe a system that incorporates thermal stability screening into formulation design using heat labile measles virus as a prototype. The screening of >11,000 unique formulations resulted in the identification of liquid formulations with marked improvement over those used in commercial monovalent measles vaccines, with <1.0 log loss of activity after incubation for 8h at 40°C. The approach was shown to be transferable to a second unrelated virus, and therefore offers significant promise towards the optimization of formulation for LAV vaccine products. Copyright © 2011 Elsevier Ltd. All rights reserved.
High voltage pulse ignition of mercury discharge hollow cathodes
NASA Technical Reports Server (NTRS)
Wintucky, E. G.
1973-01-01
A high voltage pulse generated by a capacitor discharge into a step-up transformer has been demonstrated capable of consistently igniting hollow cathode mercury discharges at propellant flows and heater power levels much below those required by conventional cathode starting. Results are presented for 3.2-mm diameter enclosed and open keeper cathodes. Starting characteristics are shown to depend on keeper voltage, mercury flow rate, heater power, keeper orifice size, emissive materials, and electrode to which the pulse is applied. This starting technique has been used to start a cathode over 10,000 times without any degradation of starting capability. The starting reliability, propellant and power savings offered by the high voltage pulse start should favorably impact performance of electron bombardment thrusters in missions requiring many on-off duty cycles.
NASA Technical Reports Server (NTRS)
Stock, J.
1979-01-01
Heat resistant paint is effective surface coating for sliding seals that must operate at elevated temperatures. Economical paint is easy to apply, offers minimal friction, and improves reliability of seals.
... Produced by the National Library of Medicine, the world’s largest medical library, it brings you information about diseases, conditions, and wellness issues in language you can understand. MedlinePlus offers reliable, ...
Laser-powered MHD generators for space application
NASA Technical Reports Server (NTRS)
Jalufka, N. W.
1986-01-01
Magnetohydrodynamic (MHD) energy conversion systems of the pulsed laser-supported detonation (LSD) wave, plasma MHD, and liquid-metal MHD (LMMHD) types are assessed for their potential as space-based laser-to-electrical power converters. These systems offer several advantages as energy converters relative to the present chemical, nuclear, and solar devices, including high conversion efficiency, simple design, high-temperature operation, high power density, and high reliability. Of these systems, the Brayton cycle liquid-metal MHD system appears to be the most attractive. The LMMHD technology base is well established for terrestrial applications, particularly with regard to the generator, mixer, and other system components. However, further research is required to extend this technology base to space applications and to establish the technology required to couple the laser energy into the system most efficiently. Continued research on each of the three system types is recommended.
Three types of solid state remote power controllers
NASA Technical Reports Server (NTRS)
Baker, D. E.
1975-01-01
Three types of solid state Remote Power Controller (RPC) circuits for 120 Vdc spacecraft distribution systems have been developed and evaluated. Both current limiting and noncurrent limiting modes of overload protection were developed and were demonstrated to be feasible. A second generation of circuits was developed which offers comparable performance with substantially less cost and complexity. Electrical efficiency for both generations is 98.5 to 99%. This paper describes various aspects of the circuit design, trade-off studies, and experimental test results. Comparisons of design parameters, component requirements, and engineering model evaluations will emphasize the high efficiency and reliability of the designs.
A Programmable System for Motion Control
NASA Technical Reports Server (NTRS)
Nowlin, Brent C.
2003-01-01
The need for improved flow measurements in the flow path of aeronautics testing facilities has led the NASA Glenn Research Center to develop a new motion control system. The new system is programmable, offering a flexibility unheard of in previous systems. The motion control system is PLC-based, which leads to highly accurate positioning ability, as well as reliability. The user interface is a software-based HMI package, which also adds flexibility to the overall system. The system also has the ability to create and execute motion profiles. This paper discusses the system's operation, control implementation, and experiences.
Two-stage optics - High-acuity performance from low-acuity optical systems
NASA Technical Reports Server (NTRS)
Meinel, Aden B.; Meinel, Marjorie P.
1992-01-01
The concept of two-stage optics, developed under a program to enhance the performance, lower the cost, and increase the reliability of the 20-m Large Deployable Telescope, is examined. The concept permits the large primary mirror to remain as deployed or as space-assembled, with phasing and subsequent control of the system done by a small fully assembled optical active element placed at an exit pupil. The technique is being applied to correction of the fabrication/testing error in the Hubble Space Telescope primary mirror. The advantages offered by this concept for very large space telescopes are discussed.
NASA Technical Reports Server (NTRS)
Pang, Jackson; Liddicoat, Albert; Ralston, Jesse; Pingree, Paula
2006-01-01
The current implementation of the Telecommunications Protocol Processing Subsystem Using Reconfigurable Interoperable Gate Arrays (TRIGA) is equipped with CFDP protocol and CCSDS Telemetry and Telecommand framing schemes to replace the CPU intensive software counterpart implementation for reliable deep space communication. We present the hardware/software co-design methodology used to accomplish high data rate throughput. The hardware CFDP protocol stack implementation is then compared against the two recent flight implementations. The results from our experiments show that TRIGA offers more than 3 orders of magnitude throughput improvement with less than one-tenth of the power consumption.
Magnetic Thin Films for Perpendicular Magnetic Recording Systems
NASA Astrophysics Data System (ADS)
Sugiyama, Atsushi; Hachisu, Takuma; Osaka, Tetsuya
In the advanced information society of today, information storage technology, which helps to store a mass of electronic data and offers high-speed random access to the data, is indispensable. Against this background, hard disk drives (HDD), which are magnetic recording devices, have gained in importance because of their advantages in capacity, speed, reliability, and production cost. These days, the uses of HDD extend not only to personal computers and network servers but also to consumer electronics products such as personal video recorders, portable music players, car navigation systems, video games, video cameras, and personal digital assistances.
DigiMesh Reliability in High Speed Vehicular Applications
NASA Astrophysics Data System (ADS)
Visan, Bogdan A.
In a fast-paced technological society, advances in wireless networking show potential to save lives. Communication is key to notifying Emergency Medical Services of a potentially deadly accident in near real-time. This paper will discuss the use of low powered wireless devices transmitting life-saving information autonomously. Current and planned technologies used in vehicles are built-in, costly, and vulnerable to physical destruction. Using an independent system can offer both old and new vehicles primary and secondary communication. The results from this research study show that vehicles can use DigiMesh as a viable solution, although relative velocity affects its performance.
New Opportunitie s for Small Satellite Programs Provided by the Falcon Family of Launch Vehicles
NASA Astrophysics Data System (ADS)
Dinardi, A.; Bjelde, B.; Insprucker, J.
2008-08-01
The Falcon family of launch vehicles, developed by Space Exploration Technologies Corporation (SpaceX), are designed to provide the world's lowest cost access to orbit. Highly reliable, low cost launch services offer considerable opportunities for risk reduction throughout the life cycle of satellite programs. The significantly lower costs of Falcon 1 and Falcon 9 as compared with other similar-class launch vehicles results in a number of new business case opportunities; which in turn presents the possibility for a paradigm shift in how the satellite industry thinks about launch services.
Dual linear accelerator system for use in sterilization of medical disposable supplies
NASA Astrophysics Data System (ADS)
Sadat, Theo
1991-05-01
Accelerators can be used for sterilization or decontamination (medical disposables, food, plastics, hospital waste, etc.). Most of these accelerators are located in an industrial environment and must have a high availability. A dual accelerator system (composed of two accelerators) offers optimal flexibility and reliability. The main advantage of this system is "all-in all-out" because it does not need a turnover of products. Such a dual system, composed of two 10 MeV 20 kW linear accelerators (instead of one 40 kW linac), has been chosen by a Swedish company (Mölnlycke).
Vertical-cavity surface-emitting lasers: the applications
NASA Astrophysics Data System (ADS)
Morgan, Robert A.; Lehman, John A.; Hibbs-Brenner, Mary K.; Liu, Yue; Bristow, Julian P. G.
1997-05-01
In this paper, we focus on how vertical-cavity surface- emitting lasers (VCSELs) and arrays have led to many feasible advanced technological applications. Their intrinsic characteristics, performance, and producibility offer substantial advantages over alternative sources. Demonstrated performance of `commercial-grade' VCSELs include low operating powers (< 2 V, mAs), high speeds (3 dB BWs > 15 GHz), and high temperature operating ranges (10 K to 400 K and -55 degree(s)C to 125 degree(s)C, and T > 200 degree(s)C). Moreover, their robustness is manifest by high reliability in excess of 107 hours mean time between failures at room temperature and tenfold improvement over existing rad-hard LEDs. Hence, even these `commercial-grade' VCSELs offer potential within cryogenic and avionics/military or space environments. We have also demonstrated submilliamp ITH, stable, single-mode VCSELs utilized within bias-free 1-Gbit/s data links. These low- power VCSELs may also serve in applications from printers to low-cost atomic clocks. The greatest near-term VCSEL applications are upgrades to low-cost LEDs and high-grade copper wire in data links and sensors. Exploiting their surface-emitting geometry, VCSELs are also compatible with established multichip module packaging. Hence VCSELs and VCSEL arrays are ideal components for interconnect-intensive processing applications between and within computing systems.
NASA Technical Reports Server (NTRS)
Hales, Stephen J.; Alexa, Joel A.; Jensen, Brian J.; Thomsen, Donald L.
2016-01-01
It is evident that nanotubes, such as carbon, boron nitride and even silicon, offer great potential for many aerospace applications. The opportunity exists to harness the extremely high strength and stiffness exhibited by high-purity, low-defect nanotubes in structural materials. Even though the technology associated with carbon nanotube (CNT) development is mature, the mechanical property benefits have yet to be fully realized. Boron nitride nanotubes (BNNTs) offer similar structural benefits, but exhibit superior chemical and thermal stability. A broader range of potential structural applications results, particularly as reinforcing agents for metal- and ceramic- based composites. However, synthesis of BNNTs is more challenging than CNTs mainly because of the higher processing temperatures required, and mass production techniques have yet to emerge. A promising technique is radio frequency plasma spray (RFPS), which is an inductively coupled, very high temperature process. The lack of electrodes and the self- contained, inert gas environment lend themselves to an ultraclean product. It is the aim of this White Paper to survey the state of the art with regard to nano-material production by analyzing the pros and cons of existing methods. The intention is to combine the best concepts and apply the NASA Langley Research Center (LaRC) RFPS facility to reliably synthesize large quantities of consistent, high-purity BNNTs.
Reliable Video Analysis Helps Security Company Grow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meurer, Dave; Furgal, Dave; Hobson, Rick
Armed Response Team (ART) has grown to become the largest locally owned security company in New Mexico. With technical assistance from Sandia National Laboratories through the New Mexico Small Business Assistance (NMSBA) Program, ART got help so they could quickly bring workable video security solutions to market. By offering a reliable video analytic camera system, they’ve been able to reduce theft, add hundreds of clients, and increase their number of employees.
Human factors of the high technology cockpit
NASA Technical Reports Server (NTRS)
Wiener, Earl L.
1990-01-01
The rapid advance of cockpit automation in the last decade has outstripped the ability of the human factors profession to understand the changes in human functions required. High technology cockpits require less physical (observable) workload, but are highly demanding of cognitive functions such as planning, alternative selection, and monitoring. Furthermore, automation creates opportunity for new and more serious forms of human error, and many pilots are concerned about the possibility of complacency affecting their performance. On the positive side, the equipment works as advertized with high reliability, offering highly efficient, computer-based flight. These findings from the cockpit studies probably apply equally to other industries, such as nuclear power production, other modes of transportation, medicine, and manufacturing, all of which traditionally have looked to aviation for technological leadership. The challenge to the human factors profession is to aid designers, operators, and training departments in exploiting the positive side of automation, while seeking solutions to the negative side. Viewgraphs are given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stettenheim, Joel
Norwich Technologies (NT) is developing a disruptively superior solar field for trough concentrating solar power (CSP). Troughs are the leading CSP technology (85% of installed capacity), being highly deployable and similar to photovoltaic (PV) systems for siting. NT has developed the SunTrap receiver, a disruptive alternative to vacuum-tube concentrating solar power (CSP) receivers, a market currently dominated by the Schott PTR-70. The SunTrap receiver will (1) operate at higher temperature (T) by using an insulated, recessed radiation-collection system to overcome the energy losses that plague vacuum-tube receivers at high T, (2) decrease acquisition costs via simpler structure, and (3) dramaticallymore » increase reliability by eliminating vacuum. It offers comparable optical efficiency with thermal loss reduction from ≥ 26% (at presently standard T) to ≥ 55% (at high T), lower acquisition costs, and near-zero O&M costs.« less
Implementing a Reliability Centered Maintenance Program at NASA's Kennedy Space Center
NASA Technical Reports Server (NTRS)
Tuttle, Raymond E.; Pete, Robert R.
1998-01-01
Maintenance practices have long focused on time based "preventive maintenance" techniques. Components were changed out and parts replaced based on how long they had been in place instead of what condition they were in. A reliability centered maintenance (RCM) program seeks to offer equal or greater reliability at decreased cost by insuring only applicable, effective maintenance is performed and by in large part replacing time based maintenance with condition based maintenance. A significant portion of this program involved introducing non-intrusive technologies, such as vibration analysis, oil analysis and I/R cameras, to an existing labor force and management team.
Digit ratio (2D : 4D) moderates the impact of sexual cues on men's decisions in ultimatum games
Van den Bergh, Bram; Dewitte, Siegfried
2006-01-01
Three experimental studies demonstrate that ‘sex-related cues’ impact human decision-making in ultimatum games. In the ultimatum game, two individuals divide a sum of money. The proposer offers a portion of the money to the other player, the responder. If the responder accepts the offer, the money is distributed in agreement with the proposer's offer. If the responder rejects the offer, neither player receives anything. Our studies show that exposure to pictures of sexy women or lingerie increases the likelihood of accepting unfair offers. Digit ratios of responders are reliably associated with their behaviour: males with lower digit ratios are more likely to reject an unfair split in neutral contexts, but more likely to accept unfair offers in sex-related contexts. PMID:16846918
Jun, Jungmi; Oh, Kyeung Mi
2015-01-01
This study examines Korean American community newspapers' representation of risks and benefits involved with medical tourism offered in Korea. Using framing theory, this research attempts to explain Korean Americans' highly positive perceptions and high willingness to use health and medical services in Korea through medical tourism rather than using such services in the United States. The result of content analyses indicated that Korean American community newspapers are rarely engaged in risk communication and lack sufficient information about potential risks of medical tourism while emphasizing diverse benefits. Korean ethnic media, as the primary source of health communication for Korean Americans, should provide more reliable health and medical information for the population's appropriate health management.
Hochfellner, Daniela; Müller, Dana; Schmucker, Alexandra
2014-12-01
The demand for comprehensive and innovative data is constantly growing in social science. In particular, micro data from various social security agencies become more and more attractive. In contrast to survey data, administrative data offer a census with highly reliable information but are restricted in their usage. To make them accessible for researchers, data or research output either have to be anonymized or released after disclosure review procedures have been used. This article discusses the trade-off between maintaining a high capability of research potential while protecting private information, by exploiting the data disclosure portfolio and the adopted disclosure strategies of the Research Data Center of the German Federal Employment Agency. © The Author(s) 2014.
Small, fast, and tough: Shrinking down integrated elastomer transducers
NASA Astrophysics Data System (ADS)
Rosset, Samuel; Shea, Herbert R.
2016-09-01
We review recent progress in miniaturized dielectric elastomer actuators (DEAs), sensors, and energy harvesters. We focus primarily on configurations where the large strain, high compliance, stretchability, and high level of integration offered by dielectric elastomer transducers provide significant advantages over other mm or μm-scale transduction technologies. We first present the most active application areas, including: tunable optics, soft robotics, haptics, micro fluidics, biomedical devices, and stretchable sensors. We then discuss the fabrication challenges related to miniaturization, such as thin membrane fabrication, precise patterning of compliant electrodes, and reliable batch fabrication of multilayer devices. We finally address the impact of miniaturization on strain, force, and driving voltage, as well as the important effect of boundary conditions on the performance of mm-scale DEAs.
O'Connor, David; Potler, Natan Vega; Kovacs, Meagan; Xu, Ting; Ai, Lei; Pellman, John; Vanderwal, Tamara; Parra, Lucas C; Cohen, Samantha; Ghosh, Satrajit; Escalera, Jasmine; Grant-Villegas, Natalie; Osman, Yael; Bui, Anastasia; Craddock, R Cameron; Milham, Michael P
2017-02-01
Although typically measured during the resting state, a growing literature is illustrating the ability to map intrinsic connectivity with functional MRI during task and naturalistic viewing conditions. These paradigms are drawing excitement due to their greater tolerability in clinical and developing populations and because they enable a wider range of analyses (e.g., inter-subject correlations). To be clinically useful, the test-retest reliability of connectivity measured during these paradigms needs to be established. This resource provides data for evaluating test-retest reliability for full-brain connectivity patterns detected during each of four scan conditions that differ with respect to level of engagement (rest, abstract animations, movie clips, flanker task). Data are provided for 13 participants, each scanned in 12 sessions with 10 minutes for each scan of the four conditions. Diffusion kurtosis imaging data was also obtained at each session. Technical validation and demonstrative reliability analyses were carried out at the connection-level using the Intraclass Correlation Coefficient and at network-level representations of the data using the Image Intraclass Correlation Coefficient. Variation in intrinsic functional connectivity across sessions was generally found to be greater than that attributable to scan condition. Between-condition reliability was generally high, particularly for the frontoparietal and default networks. Between-session reliabilities obtained separately for the different scan conditions were comparable, though notably lower than between-condition reliabilities. This resource provides a test-bed for quantifying the reliability of connectivity indices across subjects, conditions and time. The resource can be used to compare and optimize different frameworks for measuring connectivity and data collection parameters such as scan length. Additionally, investigators can explore the unique perspectives of the brain's functional architecture offered by each of the scan conditions. © The Author 2017. Published by Oxford University Press.
Maximizing the Potential of Telecommunications Technology.
ERIC Educational Resources Information Center
Young, Dennis M.
2003-01-01
Offers advice on planning a reliable and cost-effective school telecommunications system, including issues such as the layered nature of many schools' systems, and the move from centralized to distributed networks. (EV)
Reliability model of disk arrays RAID-5 with data striping
NASA Astrophysics Data System (ADS)
Rahman, P. A.; D'K Novikova Freyre Shavier, G.
2018-03-01
Within the scope of the this scientific paper, the simplified reliability model of disk arrays RAID-5 (redundant arrays of inexpensive disks) and an advanced reliability model offered by the authors taking into the consideration nonzero time of the faulty disk replacement and different failure rates of disks in normal state of the disk array and in degraded and rebuild states are discussed. The formula obtained by the authors for calculation of the mean time to data loss (MTTDL) of the RAID-5 disk arrays on basis of the advanced model is also presented. Finally, the technique of estimation of the initial reliability parameters, which are used in the reliability model, and the calculation examples of the mean time to data loss of the RAID-5 disk arrays for the different number of disks are also given.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCracken, Brewster
Through funding from the Department of Energy’s Electricity Delivery and Reliability Office, Pecan Street Inc., in partnership with Austin Energy and Oncor, developed and tested third- party data access platforms and services for Green Button offerings and for other home energy use data providers. As more utilities seek to offer Green Button-compliant data to their customers, the question continually arises of how this data can be used to help customers better manage their energy use.
Methods to Improve Reliability of Video Recorded Behavioral Data
Haidet, Kim Kopenhaver; Tate, Judith; Divirgilio-Thomas, Dana; Kolanowski, Ann; Happ, Mary Beth
2009-01-01
Behavioral observation is a fundamental component of nursing practice and a primary source of clinical research data. The use of video technology in behavioral research offers important advantages to nurse scientists in assessing complex behaviors and relationships between behaviors. The appeal of using this method should be balanced, however, by an informed approach to reliability issues. In this paper, we focus on factors that influence reliability, such as the use of sensitizing sessions to minimize participant reactivity and the importance of training protocols for video coders. In addition, we discuss data quality, the selection and use of observational tools, calculating reliability coefficients, and coding considerations for special populations based on our collective experiences across three different populations and settings. PMID:19434651
NASA Technical Reports Server (NTRS)
Wallace, Dolores R.
2003-01-01
In FY01 we learned that hardware reliability models need substantial changes to account for differences in software, thus making software reliability measurements more effective, accurate, and easier to apply. These reliability models are generally based on familiar distributions or parametric methods. An obvious question is 'What new statistical and probability models can be developed using non-parametric and distribution-free methods instead of the traditional parametric method?" Two approaches to software reliability engineering appear somewhat promising. The first study, begin in FY01, is based in hardware reliability, a very well established science that has many aspects that can be applied to software. This research effort has investigated mathematical aspects of hardware reliability and has identified those applicable to software. Currently the research effort is applying and testing these approaches to software reliability measurement, These parametric models require much project data that may be difficult to apply and interpret. Projects at GSFC are often complex in both technology and schedules. Assessing and estimating reliability of the final system is extremely difficult when various subsystems are tested and completed long before others. Parametric and distribution free techniques may offer a new and accurate way of modeling failure time and other project data to provide earlier and more accurate estimates of system reliability.
Taboada-Suarez, Antonio; Brea-García, Beatriz; Magán-Muñoz, Fernando; Couto-González, Iván; González-Álvarez, Eduardo
2015-12-01
Although autologous tissue reconstruction is the best option for breast reconstruction, using implants is still a reliable and simple method, offering acceptable aesthetic results. Becker-type implants are permanent implants that offer a 1-stage reconstructive option. A retrospective study was carried out in our center reviewing the clinical reports of 237 patients, in whom a total of 314 Becker-type prostheses were implanted. Overall survival was calculated using a Kaplan-Meier estimate. Cox proportional hazard models were used to calculate adjusted hazard ratios. At the end of the study, 214 expanders (68.15%) presented no complications, 40 (12.47%) developed significant capsular contracture, in 27 (8.60%) infection occurred, 24 (7.64%) suffered minor complications, and 9 (2.87%) ruptured. The mean survival time of the expanders was 120.41 months (95% CI: 109.62, 131.19). Radiotherapy, chemotherapy, high Molecular Immunology Borstel, age, mastectomy performed previously to the implant, ductal carcinoma, advanced tumoral stage, experience of the surgeon, and Becker 35-type implants were significantly related to a high number of complications in relation to the survival of the implants. Cox regression analysis revealed that the main risk factors for the survival of expander implants included radiotherapy and surgeon experience. The complication hazard ratio or relative risk caused by these 2 factors was 1.976 and 1.680, respectively. One-stage reconstruction using Becker-type expanders is an appropriate, simple, and reliable option in delayed breast reconstruction in patients who have not received radiotherapy and as long as the procedure is carried out by surgeons skilled in the technique.
Tung, Elizabeth; Bennett, Sara
2014-06-24
The bottom of the pyramid concept suggests that profit can be made in providing goods and services to poor people, when high volume is combined with low margins. To-date there has been very limited empirical evidence from the health sector concerning the scope and potential for such bottom of the pyramid models. This paper analyzes private for-profit (PFP) providers currently offering services to the poor on a large scale, and assesses the future prospects of bottom of the pyramid models in health. We searched published and grey literature and databases to identify PFP companies that provided more than 40,000 outpatient visits per year, or who covered 15% or more of a particular type of service in their country. For each included provider, we searched for additional information on location, target market, business model and performance, including quality of care. Only 10 large scale PFP providers were identified. The majority of these were in South Asia and most provided specialized services such as eye care. The characteristics of the business models of these firms were found to be similar to non-profit providers studied by other analysts (such as Bhattacharya 2010). They pursued social rather than traditional marketing, partnerships with government, low cost/high volume services and cross-subsidization between different market segments. There was a lack of reliable data concerning these providers. There is very limited evidence to support the notion that large scale bottom of the pyramid models in health offer good prospects for extending services to the poor in the future. In order to be successful PFP providers often require partnerships with government or support from social health insurance schemes. Nonetheless, more reliable and independent data on such schemes is needed.
2014-01-01
Background The bottom of the pyramid concept suggests that profit can be made in providing goods and services to poor people, when high volume is combined with low margins. To-date there has been very limited empirical evidence from the health sector concerning the scope and potential for such bottom of the pyramid models. This paper analyzes private for-profit (PFP) providers currently offering services to the poor on a large scale, and assesses the future prospects of bottom of the pyramid models in health. Methods We searched published and grey literature and databases to identify PFP companies that provided more than 40,000 outpatient visits per year, or who covered 15% or more of a particular type of service in their country. For each included provider, we searched for additional information on location, target market, business model and performance, including quality of care. Results Only 10 large scale PFP providers were identified. The majority of these were in South Asia and most provided specialized services such as eye care. The characteristics of the business models of these firms were found to be similar to non-profit providers studied by other analysts (such as Bhattacharya 2010). They pursued social rather than traditional marketing, partnerships with government, low cost/high volume services and cross-subsidization between different market segments. There was a lack of reliable data concerning these providers. Conclusions There is very limited evidence to support the notion that large scale bottom of the pyramid models in health offer good prospects for extending services to the poor in the future. In order to be successful PFP providers often require partnerships with government or support from social health insurance schemes. Nonetheless, more reliable and independent data on such schemes is needed. PMID:24961496
Reliable Video Analysis Helps Security Company Grow
Meurer, Dave; Furgal, Dave; Hobson, Rick
2018-05-11
Armed Response Team (ART) has grown to become the largest locally owned security company in New Mexico. With technical assistance from Sandia National Laboratories through the New Mexico Small Business Assistance (NMSBA) Program, ART got help so they could quickly bring workable video security solutions to market. By offering a reliable video analytic camera system, theyâve been able to reduce theft, add hundreds of clients, and increase their number of employees.
Jeffery, Dean; Buller, M; Wichuk, Stephanie; McDougall, Dave; Lambert, Robert GW; Maksymowych, Walter P
2017-01-01
Objective Bone marrow lesions (BML) are an MRI feature of osteoarthritis (OA) offering a potential target for therapy. We developed the Knee Inflammation MRI Scoring System (KIMRISS) to semiquantitatively score BML with high sensitivity to small changes, and compared feasibility, reliability and responsiveness versus the established MRI Osteoarthritis Knee Score (MOAKS). Methods KIMRISS incorporates a web-based graphic overlay to facilitate detailed regional BML scoring. Observers scored BML by MOAKS and KIMRISS on sagittal fluid-sensitive sequences. Exercise 1 focused on interobserver reliability in Osteoarthritis Initiative observational data, with 4 readers (two experienced/two new to KIMRISS) scoring BML in 80 patients (baseline/1 year). Exercise 2 focused on responsiveness in an open-label trial of adalimumab, with 2 experienced readers scoring BML in 16 patients (baseline/12 weeks). Results Scoring time was similar for KIMRISS and MOAKS. Interobserver reliability of KIMRISS was equivalent to MOAKS for BML status (ICC=0.84 vs 0.79), but consistently better than MOAKS for change in BML: Exercise 1 (ICC 0.82 vs 0.53), Exercise 2 (ICC 0.90 vs 0.32), and in new readers (0.87–0.92 vs 0.32–0.51). KIMRISS BML was more responsive than MOAKS BML: post-treatment BML improvement in Exercise 2 reached statistical significance for KIMRISS (SRM −0.69, p=0.015), but not MOAKS (SRM −0.12, p=0.625). KIMRISS BML also more strongly correlated to WOMAC scores than MOAKS BML (r=0.80 vs 0.58, p<0.05). Conclusions KIMRISS BML scoring was highly feasible, and was more reliable for assessment of change and more responsive to change than MOAKS BML for expert and new readers. PMID:28123780
Bloom, Benjamin; Mehta, Ambereen K.; Clark, Jeanne M.; Gudzune, Kimberly A.
2015-01-01
Objective To determine the reliability of Internet-based information on community-based weight-loss programs and grade their degree of concordance with 2013 American Heart Association, American College of Cardiology, and The Obesity Society weight management guidelines. Methods We conducted an online search for weight-loss programs in the Maryland-Washington, DC-Virginia corridor. We performed content analysis to abstract program components from their websites, and then randomly selected 80 programs for a telephone survey to verify this information. We determined reliability of Internet information in comparison with telephone interview responses. Results Of the 191 programs, we graded 1% as high, 8% as moderate, and 91% as low with respect to guideline concordance based on website content. Fifty-two programs participated in the telephone survey (65% response rate). Program intensity, diet, physical activity, and use of behavioral strategies were underreported on websites as compared to description of these activities during phone interview. Within our subsample, we graded 6% of programs as high based on website information, whereas we graded 19% as high after telephone interview. Conclusions Most weight-loss programs in an urban, mid-Atlantic region do not currently offer guideline-concordant practices and fail to disclose key information online, which may make clinician referrals challenging. PMID:26861769
Plasma-assisted physical vapor deposition surface treatments for tribological control
NASA Technical Reports Server (NTRS)
Spalvins, Talivaldis
1990-01-01
In any mechanical or engineering system where contacting surfaces are in relative motion, adhesion, wear, and friction affect reliability and performance. With the advancement of space age transportation systems, the tribological requirements have dramatically increased. This is due to the optimized design, precision tolerance requirements, and high reliability expected for solid lubricating films in order to withstand hostile operating conditions (vacuum, high-low temperatures, high loads, and space radiation). For these problem areas the ion-assisted deposition/modification processes (plasma-based and ion beam techniques) offer the greatest potential for the synthesis of thin films and the tailoring of adherence and chemical and structural properties for optimized tribological performance. The present practices and new approaches of applying soft solid lubricant and hard wear resistant films to engineering substrates are reviewed. The ion bombardment treatments have increased film adherence, lowered friction coefficients, and enhanced wear life of the solid lubricating films such as the dichalcogenides (MoS2) and the soft metals (Au, Ag, Pb). Currently, sputtering is the preferred method of applying MoS2 films; and ion plating, the soft metallic films. Ultralow friction coefficients (less than 0.01) were achieved with sputtered MoS2. Further, new diamond-like carbon and BN lubricating films are being developed by using the ion assisted deposition techniques.
A Robust, Gravity-Insensitive, High-Temperature Condenser for Water Recovery
NASA Technical Reports Server (NTRS)
Chen, Weibo; Conboy, Thomas; Ewert, Michael
2016-01-01
Regenerative life support systems are vital for NASA's future long-duration human space exploration missions. A Heat Melt Compactor (HMC) system is being developed by NASA to dry and compress trash generated during space missions. The resulting water vapor is recovered and separated from the process gas flow by a gravity-insensitive condenser. Creare is developing a high-temperature condenser for this application. The entire condenser is constructed from metals that have excellent resistance to chemical attack from contaminants and is suitable for high-temperature operation. The metal construction and design configuration also offer greatest flexibility for potential coating and regeneration processes to reduce biofilm growth and thus enhancing the reliability of the condenser. The proposed condenser builds on the gravity-insensitive phase separator technology Creare developed for aircraft and spacecraft applications. This paper will first discuss the design requirements for the condenser in an HMC system that will be demonstrated on the International Space Station (ISS). Then, it will present the overall design of the condenser and the preliminary thermal test results of a subscale condenser. Finally, this paper will discuss the predicted performance of the full-size condenser and the development plan to mature the technology and enhance its long-term reliability for a flight system.
Performance Evaluation of IEEE 802.11ah Networks With High-Throughput Bidirectional Traffic.
Šljivo, Amina; Kerkhove, Dwight; Tian, Le; Famaey, Jeroen; Munteanu, Adrian; Moerman, Ingrid; Hoebeke, Jeroen; De Poorter, Eli
2018-01-23
So far, existing sub-GHz wireless communication technologies focused on low-bandwidth, long-range communication with large numbers of constrained devices. Although these characteristics are fine for many Internet of Things (IoT) applications, more demanding application requirements could not be met and legacy Internet technologies such as Transmission Control Protocol/Internet Protocol (TCP/IP) could not be used. This has changed with the advent of the new IEEE 802.11ah Wi-Fi standard, which is much more suitable for reliable bidirectional communication and high-throughput applications over a wide area (up to 1 km). The standard offers great possibilities for network performance optimization through a number of physical- and link-layer configurable features. However, given that the optimal configuration parameters depend on traffic patterns, the standard does not dictate how to determine them. Such a large number of configuration options can lead to sub-optimal or even incorrect configurations. Therefore, we investigated how two key mechanisms, Restricted Access Window (RAW) grouping and Traffic Indication Map (TIM) segmentation, influence scalability, throughput, latency and energy efficiency in the presence of bidirectional TCP/IP traffic. We considered both high-throughput video streaming traffic and large-scale reliable sensing traffic and investigated TCP behavior in both scenarios when the link layer introduces long delays. This article presents the relations between attainable throughput per station and attainable number of stations, as well as the influence of RAW, TIM and TCP parameters on both. We found that up to 20 continuously streaming IP-cameras can be reliably connected via IEEE 802.11ah with a maximum average data rate of 160 kbps, whereas 10 IP-cameras can achieve average data rates of up to 255 kbps over 200 m. Up to 6960 stations transmitting every 60 s can be connected over 1 km with no lost packets. The presented results enable the fine tuning of RAW and TIM parameters for throughput-demanding reliable applications (i.e., video streaming, firmware updates) on one hand, and very dense low-throughput reliable networks with bidirectional traffic on the other hand.
Performance Evaluation of IEEE 802.11ah Networks With High-Throughput Bidirectional Traffic
Kerkhove, Dwight; Tian, Le; Munteanu, Adrian; De Poorter, Eli
2018-01-01
So far, existing sub-GHz wireless communication technologies focused on low-bandwidth, long-range communication with large numbers of constrained devices. Although these characteristics are fine for many Internet of Things (IoT) applications, more demanding application requirements could not be met and legacy Internet technologies such as Transmission Control Protocol/Internet Protocol (TCP/IP) could not be used. This has changed with the advent of the new IEEE 802.11ah Wi-Fi standard, which is much more suitable for reliable bidirectional communication and high-throughput applications over a wide area (up to 1 km). The standard offers great possibilities for network performance optimization through a number of physical- and link-layer configurable features. However, given that the optimal configuration parameters depend on traffic patterns, the standard does not dictate how to determine them. Such a large number of configuration options can lead to sub-optimal or even incorrect configurations. Therefore, we investigated how two key mechanisms, Restricted Access Window (RAW) grouping and Traffic Indication Map (TIM) segmentation, influence scalability, throughput, latency and energy efficiency in the presence of bidirectional TCP/IP traffic. We considered both high-throughput video streaming traffic and large-scale reliable sensing traffic and investigated TCP behavior in both scenarios when the link layer introduces long delays. This article presents the relations between attainable throughput per station and attainable number of stations, as well as the influence of RAW, TIM and TCP parameters on both. We found that up to 20 continuously streaming IP-cameras can be reliably connected via IEEE 802.11ah with a maximum average data rate of 160 kbps, whereas 10 IP-cameras can achieve average data rates of up to 255 kbps over 200 m. Up to 6960 stations transmitting every 60 s can be connected over 1 km with no lost packets. The presented results enable the fine tuning of RAW and TIM parameters for throughput-demanding reliable applications (i.e., video streaming, firmware updates) on one hand, and very dense low-throughput reliable networks with bidirectional traffic on the other hand. PMID:29360798
Write-Read 3D Patterning with a Dual-Channel Nanopipette.
Momotenko, Dmitry; Page, Ashley; Adobes-Vidal, Maria; Unwin, Patrick R
2016-09-27
Nanopipettes are becoming extremely versatile and powerful tools in nanoscience for a wide variety of applications from imaging to nanoscale sensing. Herein, the capabilities of nanopipettes to build complex free-standing three-dimensional (3D) nanostructures are demonstrated using a simple double-barrel nanopipette device. Electrochemical control of ionic fluxes enables highly localized delivery of precursor species from one channel and simultaneous (dynamic and responsive) ion conductance probe-to-substrate distance feedback with the other for reliable high-quality patterning. Nanopipettes with 30-50 nm tip opening dimensions of each channel allowed confinement of ionic fluxes for the fabrication of high aspect ratio copper pillar, zigzag, and Γ-like structures, as well as permitted the subsequent topographical mapping of the patterned features with the same nanopipette probe as used for nanostructure engineering. This approach offers versatility and robustness for high-resolution 3D "printing" (writing) and read-out at the nanoscale.
Photonic crystal nanocavity assisted rejection ratio tunable notch microwave photonic filter
Long, Yun; Xia, Jinsong; Zhang, Yong; Dong, Jianji; Wang, Jian
2017-01-01
Driven by the increasing demand on handing microwave signals with compact device, low power consumption, high efficiency and high reliability, it is highly desired to generate, distribute, and process microwave signals using photonic integrated circuits. Silicon photonics offers a promising platform facilitating ultracompact microwave photonic signal processing assisted by silicon nanophotonic devices. In this paper, we propose, theoretically analyze and experimentally demonstrate a simple scheme to realize ultracompact rejection ratio tunable notch microwave photonic filter (MPF) based on a silicon photonic crystal (PhC) nanocavity with fixed extinction ratio. Using a conventional modulation scheme with only a single phase modulator (PM), the rejection ratio of the presented MPF can be tuned from about 10 dB to beyond 60 dB. Moreover, the central frequency tunable operation in the high rejection ratio region is also demonstrated in the experiment. PMID:28067332
Photonic crystal nanocavity assisted rejection ratio tunable notch microwave photonic filter
NASA Astrophysics Data System (ADS)
Long, Yun; Xia, Jinsong; Zhang, Yong; Dong, Jianji; Wang, Jian
2017-01-01
Driven by the increasing demand on handing microwave signals with compact device, low power consumption, high efficiency and high reliability, it is highly desired to generate, distribute, and process microwave signals using photonic integrated circuits. Silicon photonics offers a promising platform facilitating ultracompact microwave photonic signal processing assisted by silicon nanophotonic devices. In this paper, we propose, theoretically analyze and experimentally demonstrate a simple scheme to realize ultracompact rejection ratio tunable notch microwave photonic filter (MPF) based on a silicon photonic crystal (PhC) nanocavity with fixed extinction ratio. Using a conventional modulation scheme with only a single phase modulator (PM), the rejection ratio of the presented MPF can be tuned from about 10 dB to beyond 60 dB. Moreover, the central frequency tunable operation in the high rejection ratio region is also demonstrated in the experiment.
Photonic crystal nanocavity assisted rejection ratio tunable notch microwave photonic filter.
Long, Yun; Xia, Jinsong; Zhang, Yong; Dong, Jianji; Wang, Jian
2017-01-09
Driven by the increasing demand on handing microwave signals with compact device, low power consumption, high efficiency and high reliability, it is highly desired to generate, distribute, and process microwave signals using photonic integrated circuits. Silicon photonics offers a promising platform facilitating ultracompact microwave photonic signal processing assisted by silicon nanophotonic devices. In this paper, we propose, theoretically analyze and experimentally demonstrate a simple scheme to realize ultracompact rejection ratio tunable notch microwave photonic filter (MPF) based on a silicon photonic crystal (PhC) nanocavity with fixed extinction ratio. Using a conventional modulation scheme with only a single phase modulator (PM), the rejection ratio of the presented MPF can be tuned from about 10 dB to beyond 60 dB. Moreover, the central frequency tunable operation in the high rejection ratio region is also demonstrated in the experiment.
Advanced energy system program
NASA Astrophysics Data System (ADS)
Trester, K.
1987-06-01
The ogjectives are to design, develop, and demonstrate a natural-gas-fueled, highly recuperated, 50 kw Brayton-cycle cogeneration system for commercial, institutional, and multifamily residential applications. Recent marketing studies have shown that the Advanced Energy System (AES), with its many cost-effective features, has the potential to offer significant reductions in annual electrical and thermal energy costs to the consumer. Specific advantates of the system that result in low cost ownership are high electrical efficiency (34 percent, LHV), low maintenance, high reliability and long life (20 years). Significant technical features include: an integral turbogenerator with shaft-speed permanent magnet generator; a rotating assembly supported by compliant foil air bearings; a formed-tubesheet plate/fin recuperator with 91 percent effectiveness; and a bi-directional power conditioner to ultilize the generator for system startup. The planned introduction of catalytic combustion will further enhance the economic and ecological attractiveness.
A novel FPGA-programmable switch matrix interconnection element in quantum-dot cellular automata
NASA Astrophysics Data System (ADS)
Hashemi, Sara; Rahimi Azghadi, Mostafa; Zakerolhosseini, Ali; Navi, Keivan
2015-04-01
The Quantum-dot cellular automata (QCA) is a novel nanotechnology, promising extra low-power, extremely dense and very high-speed structure for the construction of logical circuits at a nanoscale. In this paper, initially previous works on QCA-based FPGA's routing elements are investigated, and then an efficient, symmetric and reliable QCA programmable switch matrix (PSM) interconnection element is introduced. This element has a simple structure and offers a complete routing capability. It is implemented using a bottom-up design approach that starts from a dense and high-speed 2:1 multiplexer and utilise it to build the target PSM interconnection element. In this study, simulations of the proposed circuits are carried out using QCAdesigner, a layout and simulation tool for QCA circuits. The results demonstrate high efficiency of the proposed designs in QCA-based FPGA routing.
A taxonomy of accountable care organizations for policy and practice.
Shortell, Stephen M; Wu, Frances M; Lewis, Valerie A; Colla, Carrie H; Fisher, Elliott S
2014-12-01
To develop an exploratory taxonomy of Accountable Care Organizations (ACOs) to describe and understand early ACO development and to provide a basis for technical assistance and future evaluation of performance. Data from the National Survey of Accountable Care Organizations, fielded between October 2012 and May 2013, of 173 Medicare, Medicaid, and commercial payer ACOs. Drawing on resource dependence and institutional theory, we develop measures of eight attributes of ACOs such as size, scope of services offered, and the use of performance accountability mechanisms. Data are analyzed using a two-step cluster analysis approach that accounts for both continuous and categorical data. We identified a reliable and internally valid three-cluster solution: larger, integrated systems that offer a broad scope of services and frequently include one or more postacute facilities; smaller, physician-led practices, centered in primary care, and that possess a relatively high degree of physician performance management; and moderately sized, joint hospital-physician and coalition-led groups that offer a moderately broad scope of services with some involvement of postacute facilities. ACOs can be characterized into three distinct clusters. The taxonomy provides a framework for assessing performance, for targeting technical assistance, and for diagnosing potential antitrust violations. © Health Research and Educational Trust.
Complementary satellite sound broadcasting systems: A NASA assessment for the Voice of America
NASA Technical Reports Server (NTRS)
Stevens, Grady H.; Spence, Rodney L.
1988-01-01
Satellite concepts are examined which offer potentially significant sound broadcast coverage of audio as a complement to VOA's existing and planned terrestrial sound broadcasting system. HF bands are emphasized but additional discussion is included for systems using higher frequencies. Low altitude satellites, shuttle altitude (275 km) and sun synchronous (about 1600 to 1800 km), would not be practical for international broadcasting since many satellites would be required for reliable and widespread coverage. Two concepts are discussed which would offer significant and practical broadcast coverage at HF. One, an 8-hr posigrade equatorial orbit, would offer about 1 hr of widespread, twice daily, coverage to three areas of the globe. The time of coverage is even greater when confined to densely populated areas only (2 to 3 hrs). Another orbit, the Apogee at Constant Time/Equatorial (ACE), provides the same coverage, but only once daily to each area. The latter orbit is highly elliptical, allowing insertion of a greater payload (more broadcast channels) with the existing launch capability. The ACE and 8-hr orbit concepts led to systems of about equal costs, with the ACE being slightly better.
Sun, Jing; Song, Yue-Lin; Zhang, Jing; Huang, Zheng; Huo, Hui-Xia; Zheng, Jiao; Zhang, Qian; Zhao, Yun-Fang; Li, Jun; Tu, Peng-Fei
2015-04-08
Eggplant (Solanum melongena L.) is a famous edible and medicinal plant. Despite being widely cultivated and used, data on certain parts other than the fruit are limited. The present study focused on the qualitative and quantitative analysis of the chemical constituents, particularly phenylpropanoid amides (PAs), in eggplant. The mass fragmentation patterns of PAs were proposed using seven authentic compounds with the assistance of a hybrid ion trap time-of-flight mass spectrometer. Thirty-seven compounds (27 PAs and 10 others) were detected and plausibly assigned in the different parts of eggplant. Afterward, a reliable method based on liquid chromatography coupled with diode array detection was developed, validated, and applied for the simultaneous determination of seven PAs and three caffeoylquinic acids in 17 batches of eggplant roots with satisfactory accuracy, precision, and reproducibility, which could not only provide global chemical insight of eggplant but also offer a reliable tool for quality control.
State-of-the-art survey of joinability of materials for OTEC heat exchangers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beaver, R. J.
1978-12-01
Literature and industrial sources were surveyed to assess, on the basis of apparent economics and reliability, the joinability of both shell-and-tube and compact ocean thermal energy conversion (OTEC) heat exchangers. A no-leak requirement is mandatory to prevent mixing seawater and the ammonia working fluid. The operating temperature range considered is 7 to 28/sup 0/C (45 to 82/sup 0/F). Materials evaluated were aluminum, titanium, copper--nickel, AL-6X austenitic stainless steel, singly and in combination with steel and concrete. Many types of welding and brazing processes, roller expansion, magnaforming, O-ring sealing, and adhesive bonding were considered. The automatic gas tungsten-arc welding process andmore » explosion welding processes are the only two joining processes that now appear to offer the high reliability required of no-leak shell-and-tube heat exchangers. Of these two processes, the gas tungsten-arc welding process appears to be the more economically attractive.« less
Microsample Characterization of Coatings for Grcop-84 for High Heat Flux Applications
NASA Technical Reports Server (NTRS)
Hemker, Kevin
2003-01-01
A multidisciplinary Johns Hopkins University-NASA Glenn team is undertaking a collaborative research program to elucidate and model the thermal stability and mechanical integrity of candidate coatings for GRCop-84. GRCop-84 is a high conductivity, high strength copper alloy that was recently developed at NASA Glenn for use in high temperature, high heat flux applications. With potential applications in rocket motor combustion chamber liners, nozzle ramps and other actively cooled structures, this new material offers great potential for decreasing weight and increasing reliability of third generation reusable launch vehicles. Current emphasis has turned toward the development of environmentally resistant and thermal barrier coatings for this alloy. Metallic coatings such as NiCrAlY and Cu-8-30%Cr have shown promise in: prohibiting blanching, reducing dog-house failures, increasing operating temperatures and decreasing cooling requirements. The focus of this research program is to develop a fundamental understanding of the substrate-coating interactions that occur during thermal cycling (inter-diffusion, viscoplasticity, morphological evolution, crack formation, etc.) and to derive a science-based protocol for future coating selection, optimization and reliability assurance. The microsample tensile testing approach adopted for this study allows us to characterize small-scale and highly scale-specific coatings and properties in a way not possible by conventional means. In addition to providing much needed design data, the integration of microsample testing with detailed microstructural observations provides a mechanistic foundation for coating optimization and life prediction modeling.
Nanoionics-Based Switches for Radio-Frequency Applications
NASA Technical Reports Server (NTRS)
Nessel, James; Lee, Richard
2010-01-01
Nanoionics-based devices have shown promise as alternatives to microelectromechanical systems (MEMS) and semiconductor diode devices for switching radio-frequency (RF) signals in diverse systems. Examples of systems that utilize RF switches include phase shifters for electronically steerable phased-array antennas, multiplexers, cellular telephones and other radio transceivers, and other portable electronic devices. Semiconductor diode switches can operate at low potentials (about 1 to 3 V) and high speeds (switching times of the order of nanoseconds) but are characterized by significant insertion loss, high DC power consumption, low isolation, and generation of third-order harmonics and intermodulation distortion (IMD). MEMS-based switches feature low insertion loss (of the order of 0.2 dB), low DC power consumption (picowatts), high isolation (>30 dB), and low IMD, but contain moving parts, are not highly reliable, and must be operated at high actuation potentials (20 to 60 V) generated and applied by use of complex circuitry. In addition, fabrication of MEMS is complex, involving many processing steps. Nanoionics-based switches offer the superior RF performance and low power consumption of MEMS switches, without need for the high potentials and complex circuitry necessary for operation of MEMS switches. At the same time, nanoionics-based switches offer the high switching speed of semiconductor devices. Also, like semiconductor devices, nanoionics-based switches can be fabricated relatively inexpensively by use of conventional integrated-circuit fabrication techniques. More over, nanoionics-based switches have simple planar structures that can easily be integrated into RF power-distribution circuits.
Simultaneous control of magnetic topologies for reconfigurable vortex arrays
Im, Mi-Young; Fischer, Peter; Han, Hee-Sung; ...
2017-02-10
The topological spin textures in magnetic vortices in confined magnetic elements offer a platform for understanding the fundamental physics of nanoscale spin behavior and the potential of harnessing their unique spin structures for advanced magnetic technologies. For magnetic vortices to be practical, an effective reconfigurability of the two topologies of magnetic vortices, that is, the circularity and the polarity, is an essential prerequisite. The reconfiguration issue is highly relevant to the question of whether both circularity and polarity are reliably and efficiently controllable. In this work, we report the first direct observation of simultaneous control of both circularity and polaritymore » by the sole application of an in-plane magnetic field to arrays of asymmetrically shaped permalloy disks. Our investigation demonstrates that a high degree of reliability for control of both topologies can be achieved by tailoring the geometry of the disk arrays. We also propose a new approach to control the vortex structures by manipulating the effect of the stray field on the dynamics of vortex creation. The current study is expected to facilitate complete and effective reconfiguration of magnetic vortex structures, thereby enhancing the prospects for technological applications of magnetic vortices.« less
Simultaneous control of magnetic topologies for reconfigurable vortex arrays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Im, Mi-Young; Fischer, Peter; Han, Hee-Sung
The topological spin textures in magnetic vortices in confined magnetic elements offer a platform for understanding the fundamental physics of nanoscale spin behavior and the potential of harnessing their unique spin structures for advanced magnetic technologies. For magnetic vortices to be practical, an effective reconfigurability of the two topologies of magnetic vortices, that is, the circularity and the polarity, is an essential prerequisite. The reconfiguration issue is highly relevant to the question of whether both circularity and polarity are reliably and efficiently controllable. In this work, we report the first direct observation of simultaneous control of both circularity and polaritymore » by the sole application of an in-plane magnetic field to arrays of asymmetrically shaped permalloy disks. Our investigation demonstrates that a high degree of reliability for control of both topologies can be achieved by tailoring the geometry of the disk arrays. We also propose a new approach to control the vortex structures by manipulating the effect of the stray field on the dynamics of vortex creation. The current study is expected to facilitate complete and effective reconfiguration of magnetic vortex structures, thereby enhancing the prospects for technological applications of magnetic vortices.« less
Vertically aligned CNT-Cu nano-composite material for stacked through-silicon-via interconnects.
Sun, Shuangxi; Mu, Wei; Edwards, Michael; Mencarelli, Davide; Pierantoni, Luca; Fu, Yifeng; Jeppson, Kjell; Liu, Johan
2016-08-19
For future miniaturization of electronic systems using 3D chip stacking, new fine-pitch materials for through-silicon-via (TSV) applications are likely required. In this paper, we propose a novel carbon nanotube (CNT)/copper nanocomposite material consisting of high aspect ratio, vertically aligned CNT bundles coated with copper. These bundles, consisting of hundreds of tiny CNTs, were uniformly coated by copper through electroplating, and aspect ratios as high as 300:1 were obtained. The resistivity of this nanomaterial was found to be as low as ∼10(-8) Ω m, which is of the same order of magnitude as the resistivity of copper, and its temperature coefficient was found to be only half of that of pure copper. The main advantage of the composite TSV nanomaterial is that its coefficient of thermal expansion (CTE) is similar to that of silicon, a key reliability factor. A finite element model was set up to demonstrate the reliability of this composite material and thermal cycle simulations predicted very promising results. In conclusion, this composite nanomaterial appears to be a very promising material for future 3D TSV applications offering both a low resistivity and a low CTE similar to that of silicon.
Rodriguez Tadeo, Alejandra; Patiño Villena, Begoña; Periago Castón, María Jesús; Ros Berruezo, Gaspar; González Martínez-Lacuesta, Eduardo
2014-05-01
School canteens have rules of management and supervision of menus, however has not been assessed if they are totally consumed. To assess the acceptance of food by weigh food leftovers and validation of a methodology for visual estimation in school canteens of Murcia. Participated pupils in the second and third cycle of primary education, between 8 and 12 years. The estimate of leftovers was performed by 765 food trays. Visual estimation of 300 trays was based on a categorical scale as follow: 1 (0-25%), 2 (26-50%), 3 (51- 75%), 4 (76-100%) by two dietitians and reliability was assessed with respect to the weighed food. The reliability between both methods was assessed in two samples stratified by presence or absence of school kitchen. The first dishes with leftovers were pasta, rice and vegetable purees and was higher in those schools without kitchen (p < 0.05). Also, the second dishes poultry and fish salads and vegetables garnish. Fruit and the total sum of leftovers was higher in schools without dining menus (p < 0.05). The agreement between evaluators was high in meat dishes and salads, and substantial in vegetables, pre-cooked, omelet, pasta, fish and rice. The leftlovers are high and there are differences in the acceptance of certain foods according to the type of menu offered. The visual scale is a reliable to measure acceptance indirectly, but training to catering staff is needed. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.
NASA Astrophysics Data System (ADS)
Seiller, G.; Anctil, F.; Roy, R.
2017-09-01
This paper outlines the design and experimentation of an Empirical Multistructure Framework (EMF) for lumped conceptual hydrological modeling. This concept is inspired from modular frameworks, empirical model development, and multimodel applications, and encompasses the overproduce and select paradigm. The EMF concept aims to reduce subjectivity in conceptual hydrological modeling practice and includes model selection in the optimisation steps, reducing initial assumptions on the prior perception of the dominant rainfall-runoff transformation processes. EMF generates thousands of new modeling options from, for now, twelve parent models that share their functional components and parameters. Optimisation resorts to ensemble calibration, ranking and selection of individual child time series based on optimal bias and reliability trade-offs, as well as accuracy and sharpness improvement of the ensemble. Results on 37 snow-dominated Canadian catchments and 20 climatically-diversified American catchments reveal the excellent potential of the EMF in generating new individual model alternatives, with high respective performance values, that may be pooled efficiently into ensembles of seven to sixty constitutive members, with low bias and high accuracy, sharpness, and reliability. A group of 1446 new models is highlighted to offer good potential on other catchments or applications, based on their individual and collective interests. An analysis of the preferred functional components reveals the importance of the production and total flow elements. Overall, results from this research confirm the added value of ensemble and flexible approaches for hydrological applications, especially in uncertain contexts, and open up new modeling possibilities.
Development of the Assessment of Belief Conflict in Relationship-14 (ABCR-14)
Kyougoku, Makoto; Teraoka, Mutsumi; Masuda, Noriko; Ooura, Mariko; Abe, Yasushi
2015-01-01
Purpose Nurses and other healthcare workers frequently experience belief conflict, one of the most important, new stress-related problems in both academic and clinical fields. Methods In this study, using a sample of 1,683 nursing practitioners, we developed The Assessment of Belief Conflict in Relationship-14 (ABCR-14), a new scale that assesses belief conflict in the healthcare field. Standard psychometric procedures were used to develop and test the scale, including a qualitative framework concept and item-pool development, item reduction, and scale development. We analyzed the psychometric properties of ABCR-14 according to entropy, polyserial correlation coefficient, exploratory factor analysis, confirmatory factor analysis, average variance extracted, Cronbach’s alpha, Pearson product-moment correlation coefficient, and multidimensional item response theory (MIRT). Results The results of the analysis supported a three-factor model consisting of 14 items. The validity and reliability of ABCR-14 was suggested by evidence from high construct validity, structural validity, hypothesis testing, internal consistency reliability, and concurrent validity. The result of the MIRT offered strong support for good item response of item slope parameters and difficulty parameters. However, the ABCR-14 Likert scale might need to be explored from the MIRT point of view. Yet, as mentioned above, there is sufficient evidence to support that ABCR-14 has high validity and reliability. Conclusion The ABCR-14 demonstrates good psychometric properties for nursing belief conflict. Further studies are recommended to confirm its application in clinical practice. PMID:26247356
A preliminary psychometric evaluation of Music in Dementia Assessment Scales (MiDAS).
McDermott, Orii; Orgeta, Vasiliki; Ridder, Hanne Mette; Orrell, Martin
2014-06-01
Music in Dementia Assessment Scales (MiDAS), an observational outcome measure for music therapy with people with moderate to severe dementia, was developed from qualitative data of focus groups and interviews. Expert and peer consultations were conducted at each stage of the scale development to maximize its content validity. This study aimed to evaluate the psychometric properties of MiDAS. Care home residents with dementia attended weekly group music therapy for up to ten sessions. Music therapists and care home staff were requested to complete weekly MiDAS ratings. The Quality of Life Scale (QoL-AD) was completed at three time-points. A total of 629 (staff = 306, therapist = 323) MiDAS forms were completed. The statistical analysis revealed that MiDAS has high therapist inter-rater reliability, low staff inter-rater reliability, adequate staff test-retest reliability, adequate concurrent validity, and good construct validity. High factor loadings between the five MiDAS Visual Analogue Scale (VAS) items, levels of Interest, Response, Initiation, Involvement, and Enjoyment, were found. This study indicates that MiDAS has good psychometric properties despite the small sample size. Future research with a larger sample size could provide a more in-depth psychometric evaluation, including further exploration of the underlying factors. MiDAS provides a measure of engagement with musical experience and offers insight into who is likely to benefit on other outcomes such as quality of life or reduction in psychiatric symptoms.
Design and validation of instruments to measure knowledge.
Elliott, T E; Regal, R R; Elliott, B A; Renier, C M
2001-01-01
Measuring health care providers' learning after they have participated in educational interventions that use experimental designs requires valid, reliable, and practical instruments. A literature review was conducted. In addition, experience gained from designing and validating instruments for measuring the effect of an educational intervention informed this process. The eight main steps for designing, validating, and testing the reliability of instruments for measuring learning outcomes are presented. The key considerations and rationale for this process are discussed. Methods for critiquing and adapting existent instruments and creating new ones are offered. This study may help other investigators in developing valid, reliable, and practical instruments for measuring the outcomes of educational activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2012-01-11
GENI Project: Georgia Tech is developing a decentralized, autonomous, internet-like control architecture and control software system for the electric power grid. Georgia Tech’s new architecture is based on the emerging concept of electricity prosumers—economically motivated actors that can produce, consume, or store electricity. Under Georgia Tech’s architecture, all of the actors in an energy system are empowered to offer associated energy services based on their capabilities. The actors achieve their sustainability, efficiency, reliability, and economic objectives, while contributing to system-wide reliability and efficiency goals. This is in marked contrast to the current one-way, centralized control paradigm.
Issues in providing a reliable multicast facility
NASA Technical Reports Server (NTRS)
Dempsey, Bert J.; Strayer, W. Timothy; Weaver, Alfred C.
1990-01-01
Issues involved in point-to-multipoint communication are presented and the literature for proposed solutions and approaches surveyed. Particular attention is focused on the ideas and implementations that align with the requirements of the environment of interest. The attributes of multicast receiver groups that might lead to useful classifications, what the functionality of a management scheme should be, and how the group management module can be implemented are examined. The services that multicasting facilities can offer are presented, followed by mechanisms within the communications protocol that implements these services. The metrics of interest when evaluating a reliable multicast facility are identified and applied to four transport layer protocols that incorporate reliable multicast.
Stirling Convertor Fasteners Reliability Quantification
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Korovaichuk, Igor; Kovacevich, Tiodor; Schreiber, Jeffrey G.
2006-01-01
Onboard Radioisotope Power Systems (RPS) being developed for NASA s deep-space science and exploration missions require reliable operation for up to 14 years and beyond. Stirling power conversion is a candidate for use in an RPS because it offers a multifold increase in the conversion efficiency of heat to electric power and reduced inventory of radioactive material. Structural fasteners are responsible to maintain structural integrity of the Stirling power convertor, which is critical to ensure reliable performance during the entire mission. Design of fasteners involve variables related to the fabrication, manufacturing, behavior of fasteners and joining parts material, structural geometry of the joining components, size and spacing of fasteners, mission loads, boundary conditions, etc. These variables have inherent uncertainties, which need to be accounted for in the reliability assessment. This paper describes these uncertainties along with a methodology to quantify the reliability, and provides results of the analysis in terms of quantified reliability and sensitivity of Stirling power conversion reliability to the design variables. Quantification of the reliability includes both structural and functional aspects of the joining components. Based on the results, the paper also describes guidelines to improve the reliability and verification testing.
Reliability and Validity of Ambulatory Cognitive Assessments
Sliwinski, Martin J.; Mogle, Jacqueline A.; Hyun, Jinshil; Munoz, Elizabeth; Smyth, Joshua M.; Lipton, Richard B.
2017-01-01
Mobile technologies are increasingly used to measure cognitive function outside of traditional clinic and laboratory settings. Although ambulatory assessments of cognitive function conducted in people’s natural environments offer potential advantages over traditional assessment approaches, the psychometrics of cognitive assessment procedures have been understudied. We evaluated the reliability and construct validity of ambulatory assessments of working memory and perceptual speed administered via smartphones as part of an ecological momentary assessment (EMA) protocol in a diverse adult sample (N=219). Results indicated excellent between-person reliability (≥.97) for average scores, and evidence of reliable within-person variability across measurement occasions (.41–.53). The ambulatory tasks also exhibited construct validity, as evidence by their loadings on working memory and perceptual speed factors defined by the in-lab assessments. Our findings demonstrate that averaging across brief cognitive assessments made in uncontrolled naturalistic settings provide measurements that are comparable in reliability to assessments made in controlled laboratory environments. PMID:27084835
Hyperswitch Communication Network Computer
NASA Technical Reports Server (NTRS)
Peterson, John C.; Chow, Edward T.; Priel, Moshe; Upchurch, Edwin T.
1993-01-01
Hyperswitch Communications Network (HCN) computer is prototype multiple-processor computer being developed. Incorporates improved version of hyperswitch communication network described in "Hyperswitch Network For Hypercube Computer" (NPO-16905). Designed to support high-level software and expansion of itself. HCN computer is message-passing, multiple-instruction/multiple-data computer offering significant advantages over older single-processor and bus-based multiple-processor computers, with respect to price/performance ratio, reliability, availability, and manufacturing. Design of HCN operating-system software provides flexible computing environment accommodating both parallel and distributed processing. Also achieves balance among following competing factors; performance in processing and communications, ease of use, and tolerance of (and recovery from) faults.
The Role of PCR in the Diagnosis of Candida Vulvovaginitis-a New Gold Standard?
Sobel, J D; Akins, Robert A
2015-06-01
PCR is recognized as a reliable technique for detection of all types of microorganisms. Being highly objective and reproducible also sensitive and specific, PCR is now widely used for sexually transmitted infection (STI) diagnosis. Potential, however, exists for detecting non-pathogens, and not identifying a pathogenic state decreases specificity or clinical significance. PCR Candida tests of vaginal specimens are now widely available and frequently used offering a modest to moderate increase in sensitivity and are likely to replace traditional culture and DNA homology testing. Nevertheless, there remain considerable gaps in our knowledge regarding the usefulness and applications of these expensive tests.
Cubesat Application for Planetary Entry (CAPE) Missions: Micro-Reentry Capsule (MIRCA)
NASA Technical Reports Server (NTRS)
Esper, Jaime
2014-01-01
The Cubesat Application for Planetary Entry Missions (CAPE) concept describes a high-performing Cubesat system which includes a propulsion module and miniaturized technologies capable of surviving atmospheric entry heating, while reliably transmitting scientific and engineering data. The Micro Return Capsule (MIRCA) is CAPEs first planetary entry probe flight prototype. Within this context, this paper briefly describes CAPEs configuration and typical operational scenario, and summarizes ongoing work on the design and basic aerodynamic characteristics of the prototype MIRCA vehicle. CAPE not only opens the door to new planetary mission capabilities, it also offers relatively low-cost opportunities especially suitable to university participation.
Infrared sensors for Earth observation missions
NASA Astrophysics Data System (ADS)
Ashcroft, P.; Thorne, P.; Weller, H.; Baker, I.
2007-10-01
SELEX S&AS is developing a family of infrared sensors for earth observation missions. The spectral bands cover shortwave infrared (SWIR) channels from around 1μm to long-wave infrared (LWIR) channels up to 15μm. Our mercury cadmium telluride (MCT) technology has enabled a sensor array design that can satisfy the requirements of all of the SWIR and medium-wave infrared (MWIR) bands with near-identical arrays. This is made possible by the combination of a set of existing technologies that together enable a high degree of flexibility in the pixel geometry, sensitivity, and photocurrent integration capacity. The solution employs a photodiode array under the control of a readout integrated circuit (ROIC). The ROIC allows flexible geometries and in-pixel redundancy to maximise operability and reliability, by combining the photocurrent from a number of photodiodes into a single pixel. Defective or inoperable diodes (or "sub-pixels") can be deselected with tolerable impact on the overall pixel performance. The arrays will be fabricated using the "loophole" process in MCT grown by liquid-phase epitaxy (LPE). These arrays are inherently robust, offer high quantum efficiencies and have been used in previous space programs. The use of loophole arrays also offers access to SELEX's avalanche photodiode (APD) technology, allowing low-noise, highly uniform gain at the pixel level where photon flux is very low.
Technology review for electronically controlled braking systems
DOT National Transportation Integrated Search
1998-09-22
Electronically Controlled Braking Systems (ECBS) offer many potential benefits to the trucking industry in the areas of safety, reliability, enhanced driver feedback, and maintainability. ECBS are being tested by a number of manufacturers. These syst...
Driving at Night Can Be Deadly
DOT National Transportation Integrated Search
1996-06-17
Efficient Commercial Vehicle Operations (CVO) is imperative as manufacturers and distributors move to new technologies, faster production methods and "Just in Time" delivery. CVO must offer more reliable travel times, as well as safety and flexibilit...
Cerreia Vioglio, P; Szell, P M J; Chierotti, M R; Gobetto, R; Bryce, D L
2018-05-28
Despite the applicability of solid-state NMR to study the halogen bond, the direct NMR detection of 79/81 Br covalently bonded to carbon remains impractical due to extremely large spectral widths, even at ultra-high magnetic fields. In contrast, nuclear quadrupole resonance (NQR) offers comparatively sharp resonances. Here, we demonstrate the abilities of 79/81 Br NQR to characterize the electronic changes in the C-Br···N halogen bonding motifs found in supramolecular assemblies constructed from 1,4-dibromotetrafluorobenzene and nitrogen-containing heterocycles. An increase in the bromine quadrupolar coupling constant is observed, which correlates linearly with the halogen bond distance ( d Br···N ). Notably, 79/81 Br NQR is able to distinguish between two symmetry-independent halogen bonds in the same crystal structure. This approach offers a rapid and reliable indication for the occurrence of a halogen bond, with experimental times limited only by the observation of 79/81 Br NQR resonances.
Miniature hybrid microwave IC's using a novel thin-film technology
NASA Astrophysics Data System (ADS)
Eda, Kazuo; Miwa, Tetsuji; Taguchi, Yutaka; Uwano, Tomoki
1990-12-01
A novel thin-film technology for miniature hybrid microwave ICs is presented. All passive components, such as resistors and capacitors, are fully integrated on ordinary alumina ceramic substrates using the thin-film technology with very high yield. The numbers of parts and wiring processes were significantly reduced. This technology was applied to the fabrication of Ku-band solid-state power amplifiers. This thin-film technology offers the following advantages: (1) a very high yield fabrication process of thin-film capacitor having excellent electrical characteristics in the gigahertz range (Q = 230 at 12 GHz) and reliability: (2) two kinds of thin-film resistors having different temperature coefficients of resistivity and a lift-off process to integrate them with thin-film capacitors; and (3) a matching method using the thin-film capacitor.
Periodic Application of Concurrent Error Detection in Processor Array Architectures. PhD. Thesis -
NASA Technical Reports Server (NTRS)
Chen, Paul Peichuan
1993-01-01
Processor arrays can provide an attractive architecture for some applications. Featuring modularity, regular interconnection and high parallelism, such arrays are well-suited for VLSI/WSI implementations, and applications with high computational requirements, such as real-time signal processing. Preserving the integrity of results can be of paramount importance for certain applications. In these cases, fault tolerance should be used to ensure reliable delivery of a system's service. One aspect of fault tolerance is the detection of errors caused by faults. Concurrent error detection (CED) techniques offer the advantage that transient and intermittent faults may be detected with greater probability than with off-line diagnostic tests. Applying time-redundant CED techniques can reduce hardware redundancy costs. However, most time-redundant CED techniques degrade a system's performance.
Insights into a microwave susceptible agent for minimally invasive microwave tumor thermal therapy.
Shi, Haitang; Liu, Tianlong; Fu, Changhui; Li, Linlin; Tan, Longfei; Wang, Jingzhuo; Ren, Xiangling; Ren, Jun; Wang, Jianxin; Meng, Xianwei
2015-03-01
This work develops a kind of sodium alginate (SA) microcapsules as microwave susceptible agents for in vivo tumor microwave thermal therapy for the first time. Due to the excellent microwave susceptible properties and low bio-toxicity, excellent therapy efficiency can be achieved with the tumor inhibiting ratio of 97.85% after one-time microwave thermal therapy with ultralow power (1.8 W, 450 MHz). Meanwhile, the mechanism of high microwave heating efficiency was confirmed via computer-simulated model in theory, demonstrating that the spatial confinement efficiency of microcapsule walls endows the inside ions with high microwave susceptible properties. This strategy offers tremendous potential applications in clinical tumor treatment with the benefits of safety, reliability, effectiveness and minimally invasiveness. Copyright © 2014 Elsevier Ltd. All rights reserved.
Flexible quality of service model for wireless body area sensor networks.
Liao, Yangzhe; Leeson, Mark S; Higgins, Matthew D
2016-03-01
Wireless body area sensor networks (WBASNs) are becoming an increasingly significant breakthrough technology for smart healthcare systems, enabling improved clinical decision-making in daily medical care. Recently, radio frequency ultra-wideband technology has developed substantially for physiological signal monitoring due to its advantages such as low-power consumption, high transmission data rate, and miniature antenna size. Applications of future ubiquitous healthcare systems offer the prospect of collecting human vital signs, early detection of abnormal medical conditions, real-time healthcare data transmission and remote telemedicine support. However, due to the technical constraints of sensor batteries, the supply of power is a major bottleneck for healthcare system design. Moreover, medium access control (MAC) needs to support reliable transmission links that allow sensors to transmit data safely and stably. In this Letter, the authors provide a flexible quality of service model for ad hoc networks that can support fast data transmission, adaptive schedule MAC control, and energy efficient ubiquitous WBASN networks. Results show that the proposed multi-hop communication ad hoc network model can balance information packet collisions and power consumption. Additionally, wireless communications link in WBASNs can effectively overcome multi-user interference and offer high transmission data rates for healthcare systems.
The Advanced Gamma-Ray Imaging System (AGIS)
NASA Astrophysics Data System (ADS)
Otte, Nepomuk
The Advanced Gamma-ray Imaging System (AGIS) is a concept for the next generation of imag-ing atmospheric Cherenkov telescope arrays. It has the goal of providing an order of magnitude increase in sensitivity for Very High Energy Gamma-ray ( 100 GeV to 100 TeV) astronomy compared to currently operating arrays such as CANGAROO, HESS, MAGIC, and VERITAS. After an overview of the science such an array would enable, we discuss the development of the components of the telescope system that are required to achieve the sensitivity goal. AGIS stresses improvements in several areas of IACT technology including component reliability as well as exploring cost reduction possibilities in order to achieve its goal. We discuss alterna-tives for the telescopes and positioners: a novel Schwarzschild-Couder telescope offering a wide field of view with a relatively smaller plate scale, and possibilities for rapid slewing in order to address the search for and/or study of Gamma-ray Bursts in the VHE gamma-ray regime. We also discuss options for a high pixel count camera system providing the necessary finer solid angle per pixel and possibilities for a fast topological trigger that would offer improved realtime background rejection and lower energy thresholds.
NASA Astrophysics Data System (ADS)
Schaefli, B.; Maraun, D.; Holschneider, M.
2007-12-01
Extreme hydrological events are often triggered by exceptional co-variations of the relevant hydrometeorological processes and in particular by exceptional co-oscillations at various temporal scales. Wavelet and cross wavelet spectral analysis offers promising time-scale resolved analysis methods to detect and analyze such exceptional co-oscillations. This paper presents the state-of-the-art methods of wavelet spectral analysis, discusses related subtleties, potential pitfalls and recently developed solutions to overcome them and shows how wavelet spectral analysis, if combined to a rigorous significance test, can lead to reliable new insights into hydrometeorological processes for real-world applications. The presented methods are applied to detect potentially flood triggering situations in a high Alpine catchment for which a recent re-estimation of design floods encountered significant problems simulating the observed high flows. For this case study, wavelet spectral analysis of precipitation, temperature and discharge offers a powerful tool to help detecting potentially flood producing meteorological situations and to distinguish between different types of floods with respect to the prevailing critical hydrometeorological conditions. This opens very new perspectives for the analysis of model performances focusing on the occurrence and non-occurrence of different types of high flow events. Based on the obtained results, the paper summarizes important recommendations for future applications of wavelet spectral analysis in hydrology.
Electronic Power System Application of Diamond-Like Carbon Films
NASA Technical Reports Server (NTRS)
Wu, Richard L. C.; Kosai, H.; Fries-Carr, S.; Weimer, J.; Freeman, M.; Schwarze, G. E.
2003-01-01
A prototype manufacturing technology for producing high volume efficiency and high energy density diamond-like carbon (DLC) capacitors has been developed. Unique dual ion-beam deposition and web-handling systems have been designed and constructed to deposit high quality DLC films simultaneously on both sides of capacitor grade aluminum foil and aluminum-coated polymer films. An optimized process, using inductively coupled RF ion sources, has been used to synthesize electrically robust DLC films. DLC films are amorphous and highly flexible, making them suitable for the production of wound capacitors. DLC capacitors are reliable and stable over a wide range of AC frequencies from 20 Hz to 1 MHz, and over a temperature range from .500 C to 3000 C. The compact DLC capacitors offer at least a 50% decrease in weight and volume and a greater than 50% increase in temperature handling capability over equal value capacitors built with existing technologies. The DLC capacitors will be suitable for high temperature, high voltage, pulsed power and filter applications.
Lucero, Adam A; Addae, Gifty; Lawrence, Wayne; Neway, Beemnet; Credeur, Daniel P; Faulkner, James; Rowlands, David; Stoner, Lee
2018-01-01
What is the central question of this study? Continuous-wave near-infrared spectroscopy, coupled with venous and arterial occlusions, offers an economical, non-invasive alternative to measuring skeletal muscle blood flow and oxygen consumption, but its reliability during exercise has not been established. What is the main finding and its importance? Continuous-wave near-infrared spectroscopy devices can reliably assess local skeletal muscle blood flow and oxygen consumption from the vastus lateralis in healthy, physically active adults. The patterns of response exhibited during exercise of varying intensity agree with other published results using similar methodologies, meriting potential applications in clinical diagnosis and therapeutic assessment. Near-infrared spectroscopy (NIRS), coupled with rapid venous and arterial occlusions, can be used for the non-invasive estimation of resting local skeletal muscle blood flow (mBF) and oxygen consumption (mV̇O2), respectively. However, the day-to-day reliability of mBF and mV̇O2 responses to stressors such as incremental dynamic exercise has not been established. The aim of this study was to determine the reliability of NIRS-derived mBF and mV̇O2 responses from incremental dynamic exercise. Measurements of mBF and mV̇O2 were collected in the vastus lateralis of 12 healthy, physically active adults [seven men and five women; 25 (SD 6) years old] during three non-consecutive visits within 10 days. After 10 min rest, participants performed 3 min of rhythmic isotonic knee extension (one extension every 4 s) at 5, 10, 15, 20, 25 and 30% of maximal voluntary contraction (MVC), before four venous occlusions and then two arterial occlusions. The mBF and mV̇O2 increased proportionally with intensity [from 0.55 to 7.68 ml min -1 (100 ml) -1 and from 0.05 to 1.86 ml O 2 min -1 (100 g) -1 , respectively] up to 25% MVC, where they began to plateau at 30% MVC. Moreover, an mBF/mV̇O2 muscle oxygen consumption ratio of ∼5 was consistent for all exercise stages. The intraclass correlation coefficient for mBF indicated high to very high reliability for 10-30% MVC (0.82-0.9). There was very high reliability for mV̇O2 across all exercise stages (intraclass correlation coefficient 0.91-0.96). In conclusion, NIRS can reliably assess muscle blood flow and oxygen consumption responses to low- to moderate-intensity exercise, meriting potential applications in clinical diagnosis and therapeutic assessment. © 2017 The Authors. Experimental Physiology © 2017 The Physiological Society.
Department of Defense meteorological and environmental inputs to aviation systems
NASA Technical Reports Server (NTRS)
Try, P. D.
1983-01-01
Recommendations based on need, cost, and achievement of flight safety are offered, and the re-evaluation of weather parameters needed for safe landing operations that lead to reliable and consistent automated observation capabilities are considered.
ERIC Educational Resources Information Center
Byers, Joseph W.
1991-01-01
The most useful feature of laptop computers is portability, as one elementary school principal notes. IBM and Apple are not leaders in laptop technology. Tandy and Toshiba market relatively inexpensive models offering durability, reliable software, and sufficient memory space. (MLH)
FTA low-speed urban Maglev research program : updated lessons learned.
DOT National Transportation Integrated Search
2012-11-01
In 1999, the Federal Transit Administration (FTA) initiated the Low-Speed Urban Magnetic Levitation (Urban Maglev) Program to develop magnetic levitation technology that offers a cost-effective, reliable, and environmentally-sound transit option for ...
Probabilistic design of fibre concrete structures
NASA Astrophysics Data System (ADS)
Pukl, R.; Novák, D.; Sajdlová, T.; Lehký, D.; Červenka, J.; Červenka, V.
2017-09-01
Advanced computer simulation is recently well-established methodology for evaluation of resistance of concrete engineering structures. The nonlinear finite element analysis enables to realistically predict structural damage, peak load, failure, post-peak response, development of cracks in concrete, yielding of reinforcement, concrete crushing or shear failure. The nonlinear material models can cover various types of concrete and reinforced concrete: ordinary concrete, plain or reinforced, without or with prestressing, fibre concrete, (ultra) high performance concrete, lightweight concrete, etc. Advanced material models taking into account fibre concrete properties such as shape of tensile softening branch, high toughness and ductility are described in the paper. Since the variability of the fibre concrete material properties is rather high, the probabilistic analysis seems to be the most appropriate format for structural design and evaluation of structural performance, reliability and safety. The presented combination of the nonlinear analysis with advanced probabilistic methods allows evaluation of structural safety characterized by failure probability or by reliability index respectively. Authors offer a methodology and computer tools for realistic safety assessment of concrete structures; the utilized approach is based on randomization of the nonlinear finite element analysis of the structural model. Uncertainty of the material properties or their randomness obtained from material tests are accounted in the random distribution. Furthermore, degradation of the reinforced concrete materials such as carbonation of concrete, corrosion of reinforcement, etc. can be accounted in order to analyze life-cycle structural performance and to enable prediction of the structural reliability and safety in time development. The results can serve as a rational basis for design of fibre concrete engineering structures based on advanced nonlinear computer analysis. The presented methodology is illustrated on results from two probabilistic studies with different types of concrete structures related to practical applications and made from various materials (with the parameters obtained from real material tests).
Mi, Misa; Moseley, James L; Green, Michael L
2012-02-01
Many residency programs offer training in evidence-based medicine (EBM). However, these curricula often fail to achieve optimal learning outcomes, perhaps because they neglect various contextual factors in the learning environment. We developed and validated an instrument to characterize the environment for EBM learning and practice in residency programs. An EBM Environment Scale was developed following scale development principles. A survey was administered to residents across six programs in primary care specialties at four medical centers. Internal consistency reliability was analyzed with Cronbach's coefficient alpha. Validity was assessed by comparing predetermined subscales with the survey's internal structure as assessed via factor analysis. Scores were also compared for subgroups based on residency program affiliation and residency characteristics. Out of 262 eligible residents, 124 completed the survey (response rate 47%). The overall mean score was 3.89 (standard deviation=0.56). The initial reliability analysis of the 48-item scale had a high reliability coefficient (Cronbach α=.94). Factor analysis and further item analysis resulted in a shorter 36-item scale with a satisfactory reliability coefficient (Cronbach α=.86). Scores were higher for residents with prior EBM training in medical school (4.14 versus 3.62) and in residency (4.25 versus 3.69). If further testing confirms its properties, the EBM Environment Scale may be used to understand the influence of the learning environment on the effectiveness of EBM training. Additionally, it may detect changes in the EBM learning environment in response to programmatic or institutional interventions.
CCARES: A computer algorithm for the reliability analysis of laminated CMC components
NASA Technical Reports Server (NTRS)
Duffy, Stephen F.; Gyekenyesi, John P.
1993-01-01
Structural components produced from laminated CMC (ceramic matrix composite) materials are being considered for a broad range of aerospace applications that include various structural components for the national aerospace plane, the space shuttle main engine, and advanced gas turbines. Specifically, these applications include segmented engine liners, small missile engine turbine rotors, and exhaust nozzles. Use of these materials allows for improvements in fuel efficiency due to increased engine temperatures and pressures, which in turn generate more power and thrust. Furthermore, this class of materials offers significant potential for raising the thrust-to-weight ratio of gas turbine engines by tailoring directions of high specific reliability. The emerging composite systems, particularly those with silicon nitride or silicon carbide matrix, can compete with metals in many demanding applications. Laminated CMC prototypes have already demonstrated functional capabilities at temperatures approaching 1400 C, which is well beyond the operational limits of most metallic materials. Laminated CMC material systems have several mechanical characteristics which must be carefully considered in the design process. Test bed software programs are needed that incorporate stochastic design concepts that are user friendly, computationally efficient, and have flexible architectures that readily incorporate changes in design philosophy. The CCARES (Composite Ceramics Analysis and Reliability Evaluation of Structures) program is representative of an effort to fill this need. CCARES is a public domain computer algorithm, coupled to a general purpose finite element program, which predicts the fast fracture reliability of a structural component under multiaxial loading conditions.
1976-05-01
since the platinum silicide and titanium metals also offer very low mobility to the alkaline ions, the BLSJ . is inert to sodium . Inversion and...gettering agents for sodium ions, thus making the cont&-nination far less mobile. The stability of the structural and electrical properties of the oxide...to be an effective barrier to sodium migration. In Beam Lead Sealed ,unction (BLSJ) devices, the silicon nitride seals the devices from sodium and
1978-01-01
silicon nitride seals the devices from sodium and since the platinum silicide and titanium metals also offer very low mobility to the alkaline ions, the...of bipolar devices. These materials act as gettering agents for sodium ions, thus making the contamination far less mobile. The stability of the...parameter instability. Silicon nitride has been shown to be an effective barrier to sodium migration. In Beam Lead Sealed Junction (BLSJ) devices, the
SLAC modulator system improvements and reliability results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donaldson, A.R.
1998-06-01
In 1995, an improvement project was completed on the 244 klystron modulators in the linear accelerator. The modulator system has been previously described. This article offers project details and their resulting effect on modulator and component reliability. Prior to the project, the authors had collected four operating cycles (1991 through 1995) of MTTF data. In this discussion, the '91 data will be excluded since the modulators operated at 60 Hz. The five periods following the '91 run were reviewed due to the common repetition rate at 120 Hz.
A prototype for unsupervised analysis of tissue microarrays for cancer research and diagnostics.
Chen, Wenjin; Reiss, Michael; Foran, David J
2004-06-01
The tissue microarray (TMA) technique enables researchers to extract small cylinders of tissue from histological sections and arrange them in a matrix configuration on a recipient paraffin block such that hundreds can be analyzed simultaneously. TMA offers several advantages over traditional specimen preparation by maximizing limited tissue resources and providing a highly efficient means for visualizing molecular targets. By enabling researchers to reliably determine the protein expression profile for specific types of cancer, it may be possible to elucidate the mechanism by which healthy tissues are transformed into malignancies. Currently, the primary methods used to evaluate arrays involve the interactive review of TMA samples while they are viewed under a microscope, subjectively evaluated, and scored by a technician. This process is extremely slow, tedious, and prone to error. In order to facilitate large-scale, multi-institutional studies, a more automated and reliable means for analyzing TMAs is needed. We report here a web-based prototype which features automated imaging, registration, and distributed archiving of TMAs in multiuser network environments. The system utilizes a principal color decomposition approach to identify and characterize the predominant staining signatures of specimens in color space. This strategy was shown to be reliable for detecting and quantifying the immunohistochemical expression levels for TMAs.
NASA Astrophysics Data System (ADS)
Li, Lin; Zeng, Li; Lin, Zi-Jing; Cazzell, Mary; Liu, Hanli
2015-05-01
Test-retest reliability of neuroimaging measurements is an important concern in the investigation of cognitive functions in the human brain. To date, intraclass correlation coefficients (ICCs), originally used in inter-rater reliability studies in behavioral sciences, have become commonly used metrics in reliability studies on neuroimaging and functional near-infrared spectroscopy (fNIRS). However, as there are six popular forms of ICC, the adequateness of the comprehensive understanding of ICCs will affect how one may appropriately select, use, and interpret ICCs toward a reliability study. We first offer a brief review and tutorial on the statistical rationale of ICCs, including their underlying analysis of variance models and technical definitions, in the context of assessment on intertest reliability. Second, we provide general guidelines on the selection and interpretation of ICCs. Third, we illustrate the proposed approach by using an actual research study to assess intertest reliability of fNIRS-based, volumetric diffuse optical tomography of brain activities stimulated by a risk decision-making protocol. Last, special issues that may arise in reliability assessment using ICCs are discussed and solutions are suggested.
Preventing employee theft: 15 techniques for preventing bookkeeping embezzlement.
Hills, Laura Sachs
2004-01-01
Medical practices are unfortunately the target of embezzlement more often than you might think. This article offers practical suggestions for keeping your employees honest and thwarting a would-be embezzler. It describes the common symptoms of an embezzler at work and offers 15 practical techniques for preventing bookkeeping embezzlement. This article also suggests a simple method for conducting mini-audits from time to time and precautions to take to ensure the reliability of computer passwords. The article advocates keeping tighter control of office supplies and a method for spotting telephone abuse. Finally, it offers suggestions for dealing with employees who steal time on the job.
Methode unifiee de simulation et de conception des convertisseurs de puissance
NASA Astrophysics Data System (ADS)
Fortin Blanchette, Handy
High frequency power converters are now master piece in emerging new renewable energy applications such as hybrid vehicules. These new technologies merge the power of electrical machine with the thermal motor power. The power converters used to control those electrical machines are embeded technologies with high efficiency conversion and a high reliability. More than ground vehicule applications, embeded power converters are now present in aeronautic and aerospace domains. In this sense, high reliability and high efficiency are now important characteristics that are not only suitable but needed. In spite of this progression, power converters development remains today a complex science. Even if advanced complex techniques are now available to increase the converter stability, there are no systemic rules to design the converter physical assembly. Very often, an artistic approach is used to place the components inside the converter in the more convenient places. This lack of rigor about EMI problems is not so surprising because this kind of analysis is costly and risky. In general, to solve this type of problems, one designs a second and a third printed circuit generation which is not necessarily a quick and systematic approach. To overcome these difficulties, the main goal of this thesis is to provide simple and improved tools for power converter circuit designers. The key point are to solve EMI and reliability problems at the earlier design stage and not during the prototyping phase. Many solutions are exposed in this text about the magnetic field orientation, leakage inductances identification, power semiconductors modeling and electromagnetic modeling of power converters. The exactness of these methods is proved by using it to develop a matrix converter. The printed circuits are designed to orient properly the magnetic field enabling to introduce low power sensing circuits directly inside the converter. This application is one of the numerous possibilities offered by the techniques presented in this document. Keywords: power converters, modeling, electromagnetic interferences.
Better Minds, Better Morals: A Procedural Guide to Better Judgment.
Schaefer, G Owen; Savulescu, Julian
2017-01-01
Making more moral decisions - an uncontroversial goal, if ever there was one. But how to go about it? In this article, we offer a practical guide on ways to promote good judgment in our personal and professional lives. We will do this not by outlining what the good life consists in or which values we should accept.Rather, we offer a theory of procedural reliability : a set of dimensions of thought that are generally conducive to good moral reasoning. At the end of the day, we all have to decide for ourselves what is good and bad, right and wrong. The best way to ensure we make the right choices is to ensure the procedures we're employing are sound and reliable. We identify four broad categories of judgment to be targeted - cognitive, self-management, motivational and interpersonal. Specific factors within each category are further delineated, with a total of 14 factors to be discussed. For each, we will go through the reasons it generally leads to more morally reliable decision-making, how various thinkers have historically addressed the topic, and the insights of recent research that can offer new ways to promote good reasoning. The result is a wide-ranging survey that contains practical advice on how to make better choices. Finally, we relate this to the project of transhumanism and prudential decision-making. We argue that transhumans will employ better moral procedures like these. We also argue that the same virtues will enable us to take better control of our own lives, enhancing our responsibility and enabling us to lead better lives from the prudential perspective.
Chetwynd, Andrew J; David, Arthur; Hill, Elizabeth M; Abdul-Sada, Alaa
2014-10-01
Mass spectrometry (MS) profiling techniques are used for analysing metabolites and xenobiotics in biofluids; however, detection of low abundance compounds using conventional MS techniques is poor. To counter this, nanoflow ultra-high-pressure liquid chromatography-nanoelectrospray ionization-time-of-flight MS (nUHPLC-nESI-TOFMS), which has been used primarily for proteomics, offers an innovative prospect for profiling small molecules. Compared to conventional UHPLC-ESI-TOFMS, nUHPLC-nESI-TOFMS enhanced detection limits of a variety of (xeno)metabolites by between 2 and 2000-fold. In addition, this study demonstrates for the first time excellent repeatability and reproducibility for analysis of urine and plasma samples using nUHPLC-nESI-TOFMS, supporting implementation of this platform as a novel approach for high-throughput (xeno)metabolomics. Copyright © 2014 John Wiley & Sons, Ltd.
Payne, Hannah L
2017-01-01
Eye movements provide insights about a wide range of brain functions, from sensorimotor integration to cognition; hence, the measurement of eye movements is an important tool in neuroscience research. We describe a method, based on magnetic sensing, for measuring eye movements in head-fixed and freely moving mice. A small magnet was surgically implanted on the eye, and changes in the magnet angle as the eye rotated were detected by a magnetic field sensor. Systematic testing demonstrated high resolution measurements of eye position of <0.1°. Magnetic eye tracking offers several advantages over the well-established eye coil and video-oculography methods. Most notably, it provides the first method for reliable, high-resolution measurement of eye movements in freely moving mice, revealing increased eye movements and altered binocular coordination compared to head-fixed mice. Overall, magnetic eye tracking provides a lightweight, inexpensive, easily implemented, and high-resolution method suitable for a wide range of applications. PMID:28872455
Pulse Detonation Engines for High Speed Flight
NASA Technical Reports Server (NTRS)
Povinelli, Louis A.
2002-01-01
Revolutionary concepts in propulsion are required in order to achieve high-speed cruise capability in the atmosphere and for low cost reliable systems for earth to orbit missions. One of the advanced concepts under study is the air-breathing pulse detonation engine. Additional work remains in order to establish the role and performance of a PDE in flight applications, either as a stand-alone device or as part of a combined cycle system. In this paper, we shall offer a few remarks on some of these remaining issues, i.e., combined cycle systems, nozzles and exhaust systems and thrust per unit frontal area limitations. Currently, an intensive experimental and numerical effort is underway in order to quantify the propulsion performance characteristics of this device. In this paper, we shall highlight our recent efforts to elucidate the propulsion potential of pulse detonation engines and their possible application to high-speed or hypersonic systems.
FTA Low-speed urban maglev research program lessons learned : March 2009.
DOT National Transportation Integrated Search
2009-03-01
In 1999, the Federal Transit Administration initiated the Low-Speed Urban Magnetic Levitation (UML) Program to develop magnetic levitation technology that offers a cost effective, reliable, and environmentally sound transit option for urban mass tran...
Improved spectrophotometric analysis of fullerenes C60 and C70 in high-solubility organic solvents.
Törpe, Alexander; Belton, Daniel J
2015-01-01
Fullerenes are among a number of recently discovered carbon allotropes that exhibit unique and versatile properties. The analysis of these materials is of great importance and interest. We present previously unreported spectroscopic data for C60 and C70 fullerenes in high-solubility solvents, including error bounds, so as to allow reliable colorimetric analysis of these materials. The Beer-Lambert-Bouguer law is found to be valid at all wavelengths. The measured data were highly reproducible, and yielded high-precision molar absorbance coefficients for C60 and C70 in o-xylene and o-dichlorobenzene, which both exhibit a high solubility for these fullerenes, and offer the prospect of improved extraction efficiency. A photometric method for a C60/C70 mixture analysis was validated with standard mixtures, and subsequently improved for real samples by correcting for light scattering, using a power-law fit. The method was successfully applied to the analysis of C60/C70 mixtures extracted from fullerene soot.
High duty cycle inverse Compton scattering X-ray source
Ovodenko, A.; Agustsson, R.; Babzien, M.; ...
2016-12-22
Inverse Compton Scattering (ICS) is an emerging compact X-ray source technology, where the small source size and high spectral brightness are of interest for multitude of applications. However, to satisfy the practical flux requirements, a high-repetition-rate ICS system needs to be developed. To this end, this article reports the experimental demonstration of a high peak brightness ICS source operating in a burst mode at 40 MHz. A pulse train interaction has been achieved by recirculating a picosecond CO 2 laser pulse inside an active optical cavity synchronized to the electron beam. The pulse train ICS performance has been characterized atmore » 5- and 15- pulses per train and compared to a single pulse operation under the same operating conditions. Lastly, with the observed near-linear X-ray photon yield gain due to recirculation, as well as noticeably higher operational reliability, the burst-mode ICS offers a great potential for practical scalability towards high duty cycles.« less
Scherr, Karen A.; Fagerlin, Angela; Williamson, Lillie D.; Davis, J. Kelly; Fridman, Ilona; Atyeo, Natalie; Ubel, Peter A.
2016-01-01
Background Physicians’ recommendations affect patients’ treatment choices. However, most research relies on physicians’ or patients’ retrospective reports of recommendations, which offer a limited perspective and have limitations such as recall bias. Objective To develop a reliable and valid method to measure the strength of physician recommendations using direct observation of clinical encounters. Methods Clinical encounters (n = 257) were recorded as part of a larger study of prostate cancer decision making. We used an iterative process to create the 5-point Physician Recommendation Coding System (PhyReCS). To determine reliability, research assistants double-coded 50 transcripts. To establish content validity, we used one-way ANOVAs to determine whether relative treatment recommendation scores differed as a function of which treatment patients received. To establish concurrent validity, we examined whether patients’ perceived treatment recommendations matched our coded recommendations. Results The PhyReCS was highly reliable (Krippendorf’s alpha =. 89, 95% CI [.86, .91]). The average relative treatment recommendation score for each treatment was higher for individuals who received that particular treatment. For example, the average relative surgery recommendation score was higher for individuals who received surgery versus radiation (mean difference = .98, SE = .18, p < .001) or active surveillance (mean difference = 1.10, SE = .14, p < .001). Patients’ perceived recommendations matched coded recommendations 81% of the time. Conclusion The PhyReCS is a reliable and valid way to capture the strength of physician recommendations. We believe that the PhyReCS would be helpful for other researchers who wish to study physician recommendations, an important part of patient decision making. PMID:27343015
Scherr, Karen A; Fagerlin, Angela; Williamson, Lillie D; Davis, J Kelly; Fridman, Ilona; Atyeo, Natalie; Ubel, Peter A
2017-01-01
Physicians' recommendations affect patients' treatment choices. However, most research relies on physicians' or patients' retrospective reports of recommendations, which offer a limited perspective and have limitations such as recall bias. To develop a reliable and valid method to measure the strength of physician recommendations using direct observation of clinical encounters. Clinical encounters (n = 257) were recorded as part of a larger study of prostate cancer decision making. We used an iterative process to create the 5-point Physician Recommendation Coding System (PhyReCS). To determine reliability, research assistants double-coded 50 transcripts. To establish content validity, we used 1-way analyses of variance to determine whether relative treatment recommendation scores differed as a function of which treatment patients received. To establish concurrent validity, we examined whether patients' perceived treatment recommendations matched our coded recommendations. The PhyReCS was highly reliable (Krippendorf's alpha = 0.89, 95% CI [0.86, 0.91]). The average relative treatment recommendation score for each treatment was higher for individuals who received that particular treatment. For example, the average relative surgery recommendation score was higher for individuals who received surgery versus radiation (mean difference = 0.98, SE = 0.18, P < 0.001) or active surveillance (mean difference = 1.10, SE = 0.14, P < 0.001). Patients' perceived recommendations matched coded recommendations 81% of the time. The PhyReCS is a reliable and valid way to capture the strength of physician recommendations. We believe that the PhyReCS would be helpful for other researchers who wish to study physician recommendations, an important part of patient decision making. © The Author(s) 2016.
Olsen, J. Pat; Fellows, Robert P.; Rivera-Mindt, Monica; Morgello, Susan; Byrd, Desiree A.
2015-01-01
The Wide Range Achievement Test, 3rd edition, Reading-Recognition subtest (WRAT-3 RR) is an established measure of premorbid ability. Furthermore, its long-term reliability is not well documented, particularly in diverse populations with CNS-relevant disease. Objective: We examined test-retest reliability of the WRAT-3 RR over time in an HIV+ sample of predominantly racial/ethnic minority adults. Method: Participants (N = 88) completed a comprehensive neuropsychological battery, including the WRAT-3 RR, on at least two separate study visits. Intraclass correlation coefficients (ICCs) were computed using scores from baseline and follow-up assessments to determine the test-retest reliability of the WRAT-3 RR across racial/ethnic groups and changes in medical (immunological) and clinical (neurocognitive) factors. Additionally, Fisher’s Z tests were used to determine the significance of the differences between ICCs. Results: The average test-retest interval was 58.7 months (SD=36.4). The overall WRAT-3 RR test-retest reliability was high (r = .97, p < .001), and remained robust across all demographic, medical, and clinical variables (all r’s > .92). Intraclass correlation coefficients did not differ significantly between the subgroups tested (all Fisher’s Z p’s > .05). Conclusions: Overall, this study supports the appropriateness of word-reading tests, such as the WRAT-3 RR, for use as stable premorbid IQ estimates among ethnically diverse groups. Moreover, this study supports the reliability of this measure in the context of change in health and neurocognitive status, and in lengthy inter-test intervals. These findings offer strong rationale for reading as a “hold” test, even in the presence of a chronic, variable disease such as HIV. PMID:26689235
An on-ice measurement approach to analyse the biomechanics of ice hockey skating.
Buckeridge, Erica; LeVangie, Marc C; Stetter, Bernd; Nigg, Sandro R; Nigg, Benno M
2015-01-01
Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High) and nine low caliber (Low) hockey players performed 30 m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65) to excellent (r>0.95) scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05). High caliber exhibited greater hip range of motion and forefoot force application (p<0.05). The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice.
An On-Ice Measurement Approach to Analyse the Biomechanics of Ice Hockey Skating
Buckeridge, Erica; LeVangie, Marc C.; Stetter, Bernd; Nigg, Sandro R.; Nigg, Benno M.
2015-01-01
Skating is a fundamental movement in ice hockey; however little research has been conducted within the field of hockey skating biomechanics due to the difficulties of on-ice data collection. In this study a novel on-ice measurement approach was tested for reliability, and subsequently implemented to investigate the forward skating technique, as well as technique differences across skill levels. Nine high caliber (High) and nine low caliber (Low) hockey players performed 30m forward skating trials. A 3D accelerometer was mounted to the right skate for the purpose of stride detection, with the 2nd and 6th strides defined as acceleration and steady-state, respectively. The activity of five lower extremity muscles was recorded using surface electromyography. Biaxial electro-goniometers were used to quantify hip and knee angles, and in-skate plantar force was measured using instrumented insoles. Reliability was assessed with the coefficient of multiple correlation, which demonstrated moderate (r>0.65) to excellent (r>0.95) scores across selected measured variables. Greater plantar-flexor muscle activity and hip extension were evident during acceleration strides, while steady state strides exhibited greater knee extensor activity and hip abduction range of motion (p<0.05). High caliber exhibited greater hip range of motion and forefoot force application (p<0.05). The successful implementation of this on-ice mobile measurement approach offers potential for athlete monitoring, biofeedback and training advice. PMID:25973775
Can Internet information on vertebroplasty be a reliable means of patient self-education?
Sullivan, T Barrett; Anderson, Joshua T; Ahn, Uri M; Ahn, Nicholas U
2014-05-01
Studies of the quality and accuracy of health and medical information available on the Internet have shown that many sources provide inadequate information. However, to our knowledge, there are no published studies analyzing the quality of information available online regarding vertebroplasty. Because this has been a high-volume procedure with highly debated efficacy, it is critical that patients receive complete, accurate, and well-balanced information before deciding a treatment course. Additionally, few studies have evaluated the merit of academic site authorship or site certification on information quality, but some studies have used measurements of quality that are based primarily on subjective criteria or information accuracy rather than information completeness. The purposes of our study were (1) to evaluate and analyze the information on vertebroplasty available to the general public through the Internet; (2) to see if sites sponsored by academic institutions offered a higher quality of information; and (3) to determine whether quality of information varied according to site approval by a certification body. Three search engines were used to identify 105 web sites (35 per engine) offering information regarding vertebroplasty. Sites were evaluated for authorship/sponsorship, content, and references cited. Information quality was rated as "excellent," "high," "moderate," "low," or "unacceptable." Sites also were evaluated for contact information to set up an appointment. Data were analyzed as a complete set, then compared between authorship types, and finally evaluated by certification status. Academic sites were compared with other authorship groups and certified sites were compared with noncertified sites using Student's t-test. Appropriate indications were referenced in 74% of sites, whereas only 45% discussed a contraindication to the procedure. Benefits were expressed by 100% of sites, but risks were outlined in only 53% (p < 0.001). Ninety-nine percent of sites provided step-by-step descriptions of the procedure, and 44% of sites also included images. Alternative treatments were mentioned by 51% of sites. Twenty-seven percent of sites referenced peer-reviewed literature, 41% offered experiential or noncited data based on American populations, and 7% offered analogous data from international populations. Thirty percent of sites provided contact information for patient appointment scheduling. Seven percent of sites were classified as excellent quality, 6% as high quality, 11% as moderate quality, 19% as poor quality, and 57% as unacceptable. Sixteen percent of sites were sponsored by academic institutions, 62% by private groups, 8% by biomedical device companies, and 14% were sponsored otherwise. Academic sites reported fewer risks of the procedure than private sites or other sites (p = 0.05 and p = 0.04), but reported more risks than industry sites (p = 0.007). Academic sites were more likely than sites classified as other to offer contact information for patient appointment scheduling (p = 0.004). Nine percent of sites evaluated were Health on the Net Foundation (HONCode) certified. No association with improved information quality was observed in these sites relative to noncertified sites (all p > 0.05). Internet information regarding vertebroplasty is not only inadequate for proper patient education, but also potentially misleading as sites are more likely to present benefits of the procedure than risks. Although academic sites might be expected to offer higher-quality information than private, industry, or other sites, our data would suggest that they do not. HONCode certification cannot be used reliably as a means of qualifying website information quality. Academic sites should be expected to set a high standard and alter their Internet presence with adequate information distribution. Certification bodies also should alter their standards to necessitate provision of complete information in addition to emphasizing accurate information. Treating physicians may want to counsel their patients regarding the limitations of information present on the Internet and the pitfalls of current certification systems. Level IV, economic and decision analyses. See the Instructions for Authors for a complete description of levels of evidence.
Block 2 Solid Rocket Motor (SRM) conceptual design study. Volume 1: Appendices
NASA Technical Reports Server (NTRS)
1986-01-01
The design studies task implements the primary objective of developing a Block II Solid Rocket Motor (SRM) design offering improved flight safety and reliability. The SRM literature was reviewed. The Preliminary Development and Validation Plan is presented.
DOT National Transportation Integrated Search
2016-08-01
There is optimism that Automated Vehicles (AVs) can improve the safety of the transportation system, : reduce congestion, increase reliability, offer improved mobility solutions to all segments of the population : including the transportation-disadva...
MicroRNA Biomarkers of Toxicity in Biological Matrices
Biomarker measurements that reliably correlate with tissue injury and can be measured from sampling accessible biofluids offer enormous benefits in terms of cost, time, and convenience when assessing environmental and drug-induced toxicity in model systems or human cohorts. Micro...
Carsharing in a small city : Ithaca Carshare's first two years
DOT National Transportation Integrated Search
2011-03-01
Ithaca Carshare launched service in June 2008 as the first independent carsharing organization in New York State, offering an : affordable and reliable transportation option to the residents of the City of Ithaca and Tompkins County. During the first...
Carsharing in a small city : Ithaca Carshare's first two years.
DOT National Transportation Integrated Search
2011-03-01
Ithaca Carshare launched service in June 2008 as the first independent carsharing organization in New York State, offering an : affordable and reliable transportation option to the residents of the City of Ithaca and Tompkins County. During the first...
The impacts of freight mode splitting on congestion, risk, and delivery reliability.
DOT National Transportation Integrated Search
2012-09-01
Although splitting shipments across multiple delivery or transportation modes typically : increases total shipping costs as a result of diseconomies of scale, it may offer certain benefits : that can more than offset these costs. These benefits inclu...
Performance and reliability enhancement of linear coolers
NASA Astrophysics Data System (ADS)
Mai, M.; Rühlich, I.; Schreiter, A.; Zehner, S.
2010-04-01
Highest efficiency states a crucial requirement for modern tactical IR cryocooling systems. For enhancement of overall efficiency, AIM cryocooler designs where reassessed considering all relevant loss mechanisms and associated components. Performed investigation was based on state-of-the-art simulation software featuring magnet circuitry analysis as well as computational fluid dynamics (CFD) to realistically replicate thermodynamic interactions. As a result, an improved design for AIM linear coolers could be derived. This paper gives an overview on performance enhancement activities and major results. An additional key-requirement for cryocoolers is reliability. In recent time, AIM has introduced linear coolers with full Flexure Bearing suspension on both ends of the driving mechanism incorporating Moving Magnet piston drive. In conjunction with a Pulse-Tube coldfinger these coolers are capable of meeting MTTF's (Mean Time To Failure) in excess of 50,000 hours offering superior reliability for space applications. Ongoing development also focuses on reliability enhancement, deriving space technology into tactical solutions combining both, excelling specific performance with space like reliability. Concerned publication will summarize the progress of this reliability program and give further prospect.
High-brightness 800nm fiber-coupled laser diodes
NASA Astrophysics Data System (ADS)
Berk, Yuri; Levy, Moshe; Rappaport, Noam; Tessler, Renana; Peleg, Ophir; Shamay, Moshe; Yanson, Dan; Klumel, Genadi; Dahan, Nir; Baskin, Ilya; Shkedi, Lior
2014-03-01
Fiber-coupled laser diodes have become essential sources for fiber laser pumping and direct energy applications. Single emitters offer reliable multi-watt output power from a 100 m lateral emission aperture. By their combination and fiber coupling, pump powers up to 100 W can be achieved from a low-NA fiber pigtail. Whilst in the 9xx nm spectral range the single emitter technology is very mature with <10W output per chip, at 800nm the reliable output power from a single emitter is limited to 4 W - 5 W. Consequently, commercially available fiber coupled modules only deliver 5W - 15W at around 800nm, almost an order of magnitude down from the 9xx range pumps. To bridge this gap, we report our advancement in the brightness and reliability of 800nm single emitters. By optimizing the wafer structure, laser cavity and facet passivation process we have demonstrated QCW device operation up to 19W limited by catastrophic optical damage to the 100 μm aperture. In CW operation, the devices reach 14 W output followed by a reversible thermal rollover and a complete device shutdown at high currents, with the performance fully rebounded after cooling. We also report the beam properties of our 800nm single emitters and provide a comparative analysis with the 9xx nm single emitter family. Pump modules integrating several of these emitters with a 105 μm / 0.15 NA delivery fiber reach 35W in CW at 808 nm. We discuss the key opto-mechanical parameters that will enable further brightness scaling of multi-emitter pump modules.
Advances in a high efficiency commercial pulse tube cooler
NASA Astrophysics Data System (ADS)
Zhang, Yibing; Li, Haibing; Wang, Xiaotao; Dai, Wei; Yang, Zhaohui; Luo, Ercang
2017-12-01
The pulse tube cryocooler has the advantage of no moving part at the cold end and offers a high reliability. To further extend its use in commercial applications, efforts are still needed to improve efficiency, reliability and cost effectiveness. This paper generalizes several key innovations in our newest cooler. The cooler consists of a moving magnet compressor with dual-opposed pistons, and a co-axial cold finger. Ambient displacers are employed to recover the expansion work to increase cooling efficiency. Inside the cold finger, the conventional flow straightener screens are replaced by a tapered throat between the cold heat exchanger and the pulse tube to strengthen its immunity to the working gas contamination as well as to simplify the manufacturing processes. The cold heat exchanger is made by copper forging process which further reduces the cost. Inside the compressor, a new gas bearing design has brought in assembling simplicity and running reliability. Besides the cooler itself, electronic controller is also important for actual application. A dual channel and dual driving mode control mechanism has been selected, which reduces the vibration to a minimum, meanwhile the cool-down speed becomes faster and run-time efficiency is higher. With these innovations, the cooler TC4189 reached a no-load temperature of 44 K and provided 15 W cooling power at 80K, with an input electric power of 244 W and a cooling water temperature of 23 ℃. The efficiency reached 16.9% of Carnot at 80 K. The whole system has a total mass of 4.3 kg.
Using the reactive strength index modified to evaluate plyometric performance.
Ebben, William P; Petushek, Erich J
2010-08-01
The ability to develop force quickly is a requisite ability in most sports. The reactive strength index (RSI) has been developed as a measure of explosive strength and is derived by evaluating jump height divided by ground contact time during the depth jump (DJ). At present, the RSI is typically used to evaluate DJ performance, because it is the only plyometric exercise with an identifiable ground contact time. The purpose of this study was to introduce a modification of the RSI (RSImod) that can be used to evaluate the explosive power of any vertical plyometric exercise. This study will also assess the reliability of the RSImod, evaluate the RSImod of a variety of plyometric exercises, and examine gender differences. Twenty-six men and 23 women served as subjects. Subjects performed 3 repetitions for each of 5 plyometric exercises including the countermovement jump (CMJ), tuck jump, single-leg jump, squat jump, and dumbbell CMJ. Data were analyzed using a 2-way analysis of variance to evaluate differences in RSImod between the plyometric exercise and the interaction between plyometric exercise RSImod and gender. The analysis of RSImod revealed significant main effects for plyometric exercise type (p
Electrical impedance myography in facioscapulohumeral muscular dystrophy.
Statland, Jeffrey M; Heatwole, Chad; Eichinger, Katy; Dilek, Nuran; Martens, William B; Tawil, Rabi
2016-10-01
In this study we determined the reliability and validity of electrical impedance myography (EIM) in facioscapulohumeral muscular dystrophy (FSHD). We performed a prospective study of EIM on 16 bilateral limb and trunk muscles in 35 genetically defined and clinically affected FSHD patients (reliability testing on 18 patients). Summary scores based on body region were derived. Reactance and phase (50 and 100 kHz) were compared with measures of strength, FSHD disease severity, and functional outcomes. Participants were mostly men, mean age 53.0 years, and included a full range of severity. Limb and trunk muscles showed good to excellent reliability [intraclass correlation coefficients (ICC) 0.72-0.99]. Summary scores for the arm, leg, and trunk showed excellent reliability (ICC 0.89-0.98). Reactance was the most sensitive EIM parameter to a broad range of FSHD disease metrics. EIM is a reliable measure of muscle composition in FSHD that offers the possibility to serially evaluate affected muscles. Muscle Nerve 54: 696-701, 2016. © 2016 Wiley Periodicals, Inc.
Investigating the Intersession Reliability of Dynamic Brain-State Properties.
Smith, Derek M; Zhao, Yrian; Keilholz, Shella D; Schumacher, Eric H
2018-06-01
Dynamic functional connectivity metrics have much to offer to the neuroscience of individual differences of cognition. Yet, despite the recent expansion in dynamic connectivity research, limited resources have been devoted to the study of the reliability of these connectivity measures. To address this, resting-state functional magnetic resonance imaging data from 100 Human Connectome Project subjects were compared across 2 scan days. Brain states (i.e., patterns of coactivity across regions) were identified by classifying each time frame using k means clustering. This was done with and without global signal regression (GSR). Multiple gauges of reliability indicated consistency in the brain-state properties across days and GSR attenuated the reliability of the brain states. Changes in the brain-state properties across the course of the scan were investigated as well. The results demonstrate that summary metrics describing the clustering of individual time frames have adequate test/retest reliability, and thus, these patterns of brain activation may hold promise for individual-difference research.
Interrelation Between Safety Factors and Reliability
NASA Technical Reports Server (NTRS)
Elishakoff, Isaac; Chamis, Christos C. (Technical Monitor)
2001-01-01
An evaluation was performed to establish relationships between safety factors and reliability relationships. Results obtained show that the use of the safety factor is not contradictory to the employment of the probabilistic methods. In many cases the safety factors can be directly expressed by the required reliability levels. However, there is a major difference that must be emphasized: whereas the safety factors are allocated in an ad hoc manner, the probabilistic approach offers a unified mathematical framework. The establishment of the interrelation between the concepts opens an avenue to specify safety factors based on reliability. In cases where there are several forms of failure, then the allocation of safety factors should he based on having the same reliability associated with each failure mode. This immediately suggests that by the probabilistic methods the existing over-design or under-design can be eliminated. The report includes three parts: Part 1-Random Actual Stress and Deterministic Yield Stress; Part 2-Deterministic Actual Stress and Random Yield Stress; Part 3-Both Actual Stress and Yield Stress Are Random.
INFLUENCES OF RESPONSE RATE AND DISTRIBUTION ON THE CALCULATION OF INTEROBSERVER RELIABILITY SCORES
Rolider, Natalie U.; Iwata, Brian A.; Bullock, Christopher E.
2012-01-01
We examined the effects of several variations in response rate on the calculation of total, interval, exact-agreement, and proportional reliability indices. Trained observers recorded computer-generated data that appeared on a computer screen. In Study 1, target responses occurred at low, moderate, and high rates during separate sessions so that reliability results based on the four calculations could be compared across a range of values. Total reliability was uniformly high, interval reliability was spuriously high for high-rate responding, proportional reliability was somewhat lower for high-rate responding, and exact-agreement reliability was the lowest of the measures, especially for high-rate responding. In Study 2, we examined the separate effects of response rate per se, bursting, and end-of-interval responding. Response rate and bursting had little effect on reliability scores; however, the distribution of some responses at the end of intervals decreased interval reliability somewhat, proportional reliability noticeably, and exact-agreement reliability markedly. PMID:23322930
A Taxonomy of Accountable Care Organizations for Policy and Practice
Shortell, Stephen M; Wu, Frances M; Lewis, Valerie A; Colla, Carrie H; Fisher, Elliott S
2014-01-01
Objective To develop an exploratory taxonomy of Accountable Care Organizations (ACOs) to describe and understand early ACO development and to provide a basis for technical assistance and future evaluation of performance. Data Sources/Study Setting Data from the National Survey of Accountable Care Organizations, fielded between October 2012 and May 2013, of 173 Medicare, Medicaid, and commercial payer ACOs. Study Design Drawing on resource dependence and institutional theory, we develop measures of eight attributes of ACOs such as size, scope of services offered, and the use of performance accountability mechanisms. Data are analyzed using a two-step cluster analysis approach that accounts for both continuous and categorical data. Principal Findings We identified a reliable and internally valid three-cluster solution: larger, integrated systems that offer a broad scope of services and frequently include one or more postacute facilities; smaller, physician-led practices, centered in primary care, and that possess a relatively high degree of physician performance management; and moderately sized, joint hospital–physician and coalition-led groups that offer a moderately broad scope of services with some involvement of postacute facilities. Conclusions ACOs can be characterized into three distinct clusters. The taxonomy provides a framework for assessing performance, for targeting technical assistance, and for diagnosing potential antitrust violations. PMID:25251146
Numerical simulation of complex part manufactured by selective laser melting process
NASA Astrophysics Data System (ADS)
Van Belle, Laurent
2017-10-01
Selective Laser Melting (SLM) process belonging to the family of the Additive Manufacturing (AM) technologies, enable to build parts layer by layer, from metallic powder and a CAD model. Physical phenomena that occur in the process have the same issues as conventional welding. Thermal gradients generate significant residual stresses and distortions in the parts. Moreover, the large and complex parts to manufacturing, accentuate the undesirable effects. Therefore, it is essential for manufacturers to offer a better understanding of the process and to ensure production reliability of parts with high added value. This paper focuses on the simulation of manufacturing turbine by SLM process in order to calculate residual stresses and distortions. Numerical results will be presented.
A NEW THERMIONIC RF ELECTRON GUN FOR SYNCHROTRON LIGHT SOURCES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kutsaev, Sergey; Agustsson, R.; Hartzell, J
A thermionic RF gun is a compact and efficient source of electrons used in many practical applications. RadiaBeam Systems and the Advanced Photon Source at Argonne National Laboratory collaborate in developing of a reliable and robust thermionic RF gun for synchrotron light sources which would offer substantial improvements over existing thermionic RF guns and allow stable operation with up to 1A of beam peak current at a 100 Hz pulse repetition rate and a 1.5 μs RF pulse length. In this paper, we discuss the electromagnetic and engineering design of the cavity and report the progress towards high power testsmore » of the cathode assembly of the new gun.« less
Field programmable gate arrays: Evaluation report for space-flight application
NASA Technical Reports Server (NTRS)
Sandoe, Mike; Davarpanah, Mike; Soliman, Kamal; Suszko, Steven; Mackey, Susan
1992-01-01
Field Programmable Gate Arrays commonly called FPGA's are the newer generation of field programmable devices and offer more flexibility in the logic modules they incorporate and in how they are interconnected. The flexibility, the number of logic building blocks available, and the high gate densities achievable are why users find FPGA's attractive. These attributes are important in reducing product development costs and shortening the development cycle. The aerospace community is interested in incorporating this new generation of field programmable technology in space applications. To this end, a consortium was formed to evaluate the quality, reliability, and radiation performance of FPGA's. This report presents the test results on FPGA parts provided by ACTEL Corporation.
Single-shot turbo spin echo acquisition for in vivo cardiac diffusion MRI.
Edalati, Masoud; Lee, Gregory R; Hui Wang; Taylor, Michael D; Li, Yu Y
2016-08-01
Diffusion MRI offers the ability to noninvasively characterize the microstructure of myocardium tissue and detect disease related pathology in cardiovascular examination. This study investigates the feasibility of in vivo cardiac diffusion MRI under free-breathing condition. A high-speed imaging technique, correlation imaging, is used to enable single-shot turbo spin echo for free-breathing cardiac data acquisition. The obtained in vivo cardiac diffusion-weighted images illustrate robust image quality and minor geometry distortions. The resultant diffusion scalar maps show reliable quantitative values consistent with those previously published in the literature. It is demonstrated that this technique has the potential for in vivo free-breathing cardiac diffusion MRI.
Preliminary Solar Sail Design and Fabrication Assessment: Spinning Sail Blade, Square Sail Sheet
NASA Technical Reports Server (NTRS)
Daniels, J. B.; Dowdle, D. M.; Hahn, D. W.; Hildreth, E. N.; Lagerquist, D. R.; Mahaonoul, E. J.; Munson, J. B.; Origer, T. F.
1977-01-01
Blade design aspects most affecting producibility and means of measurement and control of length, scallop, fullness and straightness requirements and tolerances were extensively considered. Alternate designs of the panel seams and edge reinforcing members are believed to offer advantages of seam integrity, producibility, reliability, cost and weight. Approaches to and requirements for highly specialized metalizing methods, processes and equipment were studied and identified. Alternate methods of sail blade fabrication and related special machinery, tooling, fixtures and trade offs were examined. A preferred and recommended approach is also described. Quality control plans, inspection procedures, flow charts and special test equipment associated with the preferred manufacturing method were analyzed and are discussed.
Unreliable Yet Still Replicable: A Comment on LeBel and Paunonen (2011)
De Schryver, Maarten; Hughes, Sean; Rosseel, Yves; De Houwer, Jan
2016-01-01
Lebel and Paunonen (2011) highlight that despite their importance and popularity in both theoretical and applied research, many implicit measures continue to be plagued by a persistent and troublesome issue—low reliability. In their paper, they offer a conceptual analysis of the relationship between reliability, power and replicability, and then provide a series of recommendations for researchers interested in using implicit measures in an experimental setting. At the core of their account is the idea that reliability can be equated with statistical power, such that “lower levels of reliability are associated with decreasing probabilities of detecting a statistically significant effect, given one exists in the population” (p. 573). They also take the additional step of equating reliability and replicability. In our commentary, we draw attention to the fact that there is no direct, fixed or one-to-one relation between reliability and power or replicability. More specifically, we argue that when adopting an experimental (rather than a correlational) approach, researchers strive to minimize inter-individual variation, which has a direct impact on sample based reliability estimates. We evaluate the strengths and weaknesses of the LeBel and Paunonen's recommendations and refine them where appropriate. PMID:26793150
Enabling skin vaccination using new delivery technologies
Kim, Yeu-Chun; Prausnitz, Mark R.
2011-01-01
The skin is known to be a highly immunogenic site for vaccination, but few vaccines in clinical use target skin largely because conventional intradermal injection is difficult and unreliable to perform. Now, a number of new or newly adapted delivery technologies have been shown to administer vaccine to the skin either by non-invasive or minimally invasive methods. Non-invasive methods include high-velocity powder and liquid jet injection, as well as diffusion-based patches in combination with skin abrasion, thermal ablation, ultrasound, electroporation, and chemical enhancers. Minimally invasive methods are generally based on small needles, including solid microneedle patches, hollow microneedle injections, and tattoo guns. The introduction of these advanced delivery technologies can make the skin a site for simple, reliable vaccination that increases vaccine immunogenicity and offers logistical advantages to improve the speed and coverage of vaccination. PMID:21799951
Enabling skin vaccination using new delivery technologies
Kim, Yeu-Chun; Prausnitz, Mark R.
2011-01-01
The skin is known to be a highly immunogenic site for vaccination, but few vaccines in clinical use target skin largely because conventional intradermal injection is difficult and unreliable to perform. Now, a number of new or newly adapted delivery technologies have been shown to administer vaccine to the skin either by non-invasive or minimally invasive methods. Non-invasive methods include high-velocity powder and liquid jet injection, as well as diffusion-based patches in combination with skin abrasion, thermal ablation, ultrasound, electroporation, and chemical enhancers. Minimally invasive methods are generally based on small needles, including solid microneedle patches, hollow microneedle injections and tattoo guns. The introduction of these advanced delivery technologies can make the skin a site for simple, reliable vaccination that increases vaccine immunogenicity and offers logistical advantages to improve the speed and coverage of vaccination. PMID:21472533
Superthin Solar Cells Based on AIIIBV/Ge Heterostructures
NASA Astrophysics Data System (ADS)
Pakhanov, N. A.; Pchelyakov, O. P.; Vladimirov, V. M.
2017-11-01
A comparative analysis of the prospects of creating superthin, light-weight, and highly efficient solar cells based on AIIIBV/InGaAs and AIIIBV/Ge heterostructures is performed. Technological problems and prospects of each variant are discussed. A method of thinning of AIIIBV/Ge heterostructures with the use of an effective temporary carrier is proposed. The method allows the process to be performed almost with no risk of heterostructure fracture, thinning of the Ge junction down to several tens of micrometers (or even several micrometers), significant enhancement of the yield of good structures, and also convenient and reliable transfer of thinned solar cells to an arbitrary light and flexible substrate. Such a technology offers a possibility of creating high-efficiency thin and light solar cells for space vehicles on the basis of mass-produced AIIIBV/Ge heterostructures.
High-temperature brazing for reliable tungsten CFC joints
NASA Astrophysics Data System (ADS)
Koppitz, Th; Pintsuk, G.; Reisgen, U.; Remmel, J.; Hirai, T.; Sievering, R.; Rojas, Y.; Casalegno, V.
2007-03-01
The joining of tungsten and carbon-based materials is demanding due to the incompatibility of their chemical and thermophysical properties. Direct joining is unfeasible by the reason of brittle tungsten carbide formation. High-temperature brazing has been investigated in order to find a suitable brazing filler metal (BFM) which successfully acts as an intermediary between the incompatible properties of the base materials. So far only low Cr-alloyed Cu-based BFMs provide the preferential combination of good wetting action on both materials, tolerable interface reactions, and a precipitation free braze joint. Attempts to implement a higher melting metal (e.g. Pd, Ti, Zr) as a BFM have failed up to now, because the formation of brittle precipitations and pores in the seam were inevitable. But the wide metallurgical complexity of this issue is regarded to offer further joining potential.
Lenz, Tobias L; Eizaguirre, Christophe; Becker, Sven; Reusch, Thorsten BH
2009-01-01
Background In all jawed vertebrates, highly polymorphic genes of the major histocompatibility complex (MHC) encode antigen presenting molecules that play a key role in the adaptive immune response. Their polymorphism is composed of multiple copies of recently duplicated genes, each possessing many alleles within populations, as well as high nucleotide divergence between alleles of the same species. Experimental evidence is accumulating that MHC polymorphism is a result of balancing selection by parasites and pathogens. In order to describe MHC diversity and analyse the underlying mechanisms that maintain it, a reliable genotyping technique is required that is suitable for such highly variable genes. Results We present a genotyping protocol that uses Reference Strand-mediated Conformation Analysis (RSCA), optimised for recently duplicated MHC class IIB genes that are typical for many fish and bird species, including the three-spined stickleback, Gasterosteus aculeatus. In addition we use a comprehensive plasmid library of MHC class IIB alleles to determine the nucleotide sequence of alleles represented by RSCA allele peaks. Verification of the RSCA typing by cloning and sequencing demonstrates high congruency between both methods and provides new insight into the polymorphism of classical stickleback MHC genes. Analysis of the plasmid library additionally reveals the high resolution and reproducibility of the RSCA technique. Conclusion This new RSCA genotyping protocol offers a fast, but sensitive and reliable way to determine the MHC allele repertoire of three-spined sticklebacks. It therefore provides a valuable tool to employ this highly polymorphic and adaptive marker in future high-throughput studies of host-parasite co-evolution and ecological speciation in this emerging model organism. PMID:19291291
Hussain, Aftab M; Hussain, Muhammad M
2016-06-01
Flexible and stretchable electronics can dramatically enhance the application of electronics for the emerging Internet of Everything applications where people, processes, data and devices will be integrated and connected, to augment quality of life. Using naturally flexible and stretchable polymeric substrates in combination with emerging organic and molecular materials, nanowires, nanoribbons, nanotubes, and 2D atomic crystal structured materials, significant progress has been made in the general area of such electronics. However, high volume manufacturing, reliability and performance per cost remain elusive goals for wide commercialization of these electronics. On the other hand, highly sophisticated but extremely reliable, batch-fabrication-capable and mature complementary metal oxide semiconductor (CMOS)-based technology has facilitated tremendous growth of today's digital world using thin-film-based electronics; in particular, bulk monocrystalline silicon (100) which is used in most of the electronics existing today. However, one fundamental challenge is that state-of-the-art CMOS electronics are physically rigid and brittle. Therefore, in this work, how CMOS-technology-enabled flexible and stretchable electronics can be developed is discussed, with particular focus on bulk monocrystalline silicon (100). A comprehensive information base to realistically devise an integration strategy by rational design of materials, devices and processes for Internet of Everything electronics is offered. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Feasibility assessment of optical technologies for reliable high capacity feeder links
NASA Astrophysics Data System (ADS)
Witternigg, Norbert; Schönhuber, Michael; Leitgeb, Erich; Plank, Thomas
2013-08-01
Space telecom scenarios like data relay satellite and broadband/broadcast service providers require reliable feeder links with high bandwidth/data rate for the communication between ground station and satellite. Free space optical communication (FSOC) is an attractive alternative to microwave links, improving performance by offering abundant bandwidth at small apertures of the optical terminals. At the same time Near-Earth communication by FSOC avoids interference with other services and is free of regulatory issues. The drawback however is the impairment by the laser propagation through the atmosphere at optical wavelengths. Also to be considered are questions of eye safety for ground personnel and aviation. In this paper we assess the user requirements for typical space telecom scenarios and compare these requirements with solutions using optical data links through the atmosphere. We suggest a site diversity scheme with a number of ground stations and a switching scheme using two optical terminals on-board the satellite. Considering the technology trade-offs between four different optical wavelengths we recommend the future use of 1.5 μm laser technology and calculate a link budget for an atmospheric condition of light haze on the optical path. By comparing link budgets we show an outlook to the future potential use of 10 μm laser technology.
Development and Validation of the Escala de Actitudes Emprendedoras para Estudiantes (EAEE).
Oliver, Amparo; Galiana, Laura
2015-03-17
During the last few years, entrepreneurship has gained an important role in many economic and social policies, with the consequent growth of entrepreneurial research in many social areas. However, in the Spanish psychometric context, there is not an updated scale including recent contributions to entrepreneurship attitudes literature. The aim of this study is to present and validate a new scale named Escala de Actitudes Emprendedoras para Estudiantes-EAEE, (Entrepreneurial Attitudes Scale for Students, EASS), in two samples of high school and university Spanish students. Data comes from a cross-sectional survey of 524 high school and undergraduate students, from Valencia (Spain). Two confirmatory factor analyses (CFAs) were estimated, together with reliability and validity evidence of the scale. Results offered evidence of the adequate psychometric properties of the EASS. The CFAs showed overall and analytical adequate fit indexes (χ 2 (120) = 163.19 (p < .01), GFI = .906, CFI = .959, SRMR = .044, RMSEA = .040 [CI .022-.054]); reliability indices of the entrepreneurial attitudes were appropriate for most of the entrepreneurial attitudes (α were between .63 and .87 for the different dimensions); and external evidence relating entrepreneurial dimensions to personality traits was similar to in previous studies. The scale could be a useful instrument both for previous diagnosis and effectiveness assessment of programs on entrepreneurship promotion.
NASA Astrophysics Data System (ADS)
Kim, Young Lae
For 20 years, single walled carbon nanotubes (SWNTs) have been studied actively due to their unique one-dimensional nanostructure and superior electrical, thermal, and mechanical properties. For these reasons, they offer the potential to serve as building blocks for future electronic devices such as field effect transistors (FETs), electromechanical devices, and various sensors. In order to realize these applications, it is crucial to develop a simple, scalable, and reliable nanomanufacturing process that controllably places aligned SWNTs in desired locations, orientations, and dimensions. Also electronic properties (semiconducting/metallic) of SWNTs and their organized networks must be controlled for the desired performance of devices and systems. These fundamental challenges are significantly limiting the use of SWNTs for future electronic device applications. Here, we demonstrate a strategy to fabricate highly controlled micro/nanoscale SWNT network structures and present the related assembly mechanism to engineer the SWNT network topology and its electrical transport properties. A method designed to evaluate the electrical reliability of such nano- and microscale SWNT networks is also presented. Moreover, we develop and investigate a robust SWNT based multifunctional selective chemical sensor and a range of multifunctional optoelectronic switches, photo-transistors, optoelectronic logic gates and complex optoelectronic digital circuits.
Liuzzo, Derek M; Peters, Denise M; Middleton, Addie; Lanier, Wes; Chain, Rebecca; Barksdale, Brittany; Fritz, Stacy L
Clinicians and researchers have used bathroom scales, balance performance monitors with feedback, postural scale analysis, and force platforms to evaluate weight bearing asymmetry (WBA). Now video game consoles offer a novel alternative for assessing this construct. By using specialized software, the Nintendo Wii Fit balance board can provide reliable measurements of WBA in healthy, young adults. However, reliability of measurements obtained using only the factory settings to assess WBA in older adults and individuals with stroke has not been established. To determine whether measurements of WBA obtained using the Nintendo Wii Fit balance board and default settings are reliable in older adults and individuals with stroke. Weight bearing asymmetry was assessed using the Nintendo Wii Fit balance board in 2 groups of participants-individuals older than 65 years (n = 41) and individuals with stroke (n = 41). Participants were given a standardized set of instructions and were not provided auditory or visual feedback. Two trials were performed. Intraclass correlation coefficients (ICC), standard error of measure (SEM), and minimal detectable change (MDC) scores were determined for each group. The ICC for the older adults sample was 0.59 (0.35-0.76) with SEM95 = 6.2% and MDC95 = 8.8%. The ICC for the sample including individuals with stroke was 0.60 (0.47-0.70) with SEM95 = 9.6% and MDC95 = 13.6%. Although measurements of WBA obtained using the Nintendo Wii Fit balance board, and its default factory settings, demonstrate moderate reliability in older adults and individuals with stroke, the relatively high associated SEM and MDC values substantially reduce the clinical utility of the Nintendo Wii Fit balance board as an assessment tool for WBA. Weight bearing asymmetry cannot be measured reliably in older adults and individuals with stroke using the Nintendo Wii Fit balance board without the use of specialized software.
Liuzzo, Derek M.; Peters, Denise M.; Middleton, Addie; Lanier, Wes; Chain, Rebecca; Barksdale, Brittany; Fritz, Stacy L.
2015-01-01
Background Clinicians and researchers have used bathroom scales, balance performance monitors with feedback, postural scale analysis, and force platforms to evaluate weight bearing asymmetry (WBA). Now video game consoles offer a novel alternative for assessing this construct. By using specialized software, the Nintendo Wii Fit balance board can provide reliable measurements of WBA in healthy, young adults. However, reliability of measurements obtained using only the factory settings to assess WBA in older adults and individuals with stroke has not been established. Purpose To determine whether measurements of WBA obtained using the Nintendo Wii Fit balance board and default settings are reliable in older adults and individuals with stroke. Methods Weight bearing asymmetry was assessed using the Nintendo Wii Fit balance board in 2 groups of participants—individuals older than 65 years (n = 41) and individuals with stroke (n = 41). Participants were given a standardized set of instructions and were not provided auditory or visual feedback. Two trials were performed. Intraclass correlation coefficients (ICC), standard error of measure (SEM), and minimal detectable change (MDC) scores were determined for each group. Results The ICC for the older adults sample was 0.59 (0.35–0.76) with SEM95= 6.2% and MDC95= 8.8%. The ICC for the sample including individuals with stroke was 0.60 (0.47–0.70) with SEM95= 9.6% and MDC95= 13.6%. Discussion Although measurements of WBA obtained using the Nintendo Wii Fit balance board, and its default factory settings, demonstrate moderate reliability in older adults and individuals with stroke, the relatively high associated SEM and MDC values substantially reduce the clinical utility of the Nintendo Wii Fit balance board as an assessment tool for WBA. Conclusions Weight bearing asymmetry cannot be measured reliably in older adults and individuals with stroke using the Nintendo Wii Fit balance board without the use of specialized software. PMID:26288237
Ganasegeran, Kurubaran; Selvaraj, Kamaraj; Rashid, Abdul
2017-08-01
The six item Confusion, Hubbub and Order Scale (CHAOS-6) has been validated as a reliable tool to measure levels of household disorder. We aimed to investigate the goodness of fit and reliability of a new Malay version of the CHAOS-6. The original English version of the CHAOS-6 underwent forward-backward translation into the Malay language. The finalised Malay version was administered to 105 myocardial infarction survivors in a Malaysian cardiac health facility. We performed confirmatory factor analyses (CFAs) using structural equation modelling. A path diagram and fit statistics were yielded to determine the Malay version's validity. Composite reliability was tested to determine the scale's reliability. All 105 myocardial infarction survivors participated in the study. The CFA yielded a six-item, one-factor model with excellent fit statistics. Composite reliability for the single factor CHAOS-6 was 0.65, confirming that the scale is reliable for Malay speakers. The Malay version of the CHAOS-6 was reliable and showed the best fit statistics for our study sample. We thus offer a simple, brief, validated, reliable and novel instrument to measure chaos, the Skala Kecelaruan, Keriuhan & Tertib Terubahsuai (CHAOS-6) , for the Malaysian population.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patton, A.D.; Ayoub, A.K.; Singh, C.
1982-07-01
Existing methods for generating capacity reliability evaluation do not explicitly recognize a number of operating considerations which may have important effects in system reliability performance. Thus, current methods may yield estimates of system reliability which differ appreciably from actual observed reliability. Further, current methods offer no means of accurately studying or evaluating alternatives which may differ in one or more operating considerations. Operating considerations which are considered to be important in generating capacity reliability evaluation include: unit duty cycles as influenced by load cycle shape, reliability performance of other units, unit commitment policy, and operating reserve policy; unit start-up failuresmore » distinct from unit running failures; unit start-up times; and unit outage postponability and the management of postponable outages. A detailed Monte Carlo simulation computer model called GENESIS and two analytical models called OPCON and OPPLAN have been developed which are capable of incorporating the effects of many operating considerations including those noted above. These computer models have been used to study a variety of actual and synthetic systems and are available from EPRI. The new models are shown to produce system reliability indices which differ appreciably from index values computed using traditional models which do not recognize operating considerations.« less
NASA Astrophysics Data System (ADS)
Li, Yanrong; Wang, Jinxia
2018-06-01
Surface water, as the largest part of water resources, plays an important role on China's agricultural production and food security. And surface water is vulnerable to climate change. This paper aims to examine the status of the supply reliability of surface water irrigation, and discusses how it is affected by climate change in rural China. The field data we used in this study was collected from a nine-province field survey during 2012 and 2013. Climate data are offered by China's National Meteorological Information Center which contains temperature and precipitation in the past 30 years. A Tobit model (or censored regression model) was used to estimate the influence of climate change on supply reliability of surface water irrigation. Descriptive results showed that, surface water supply reliability was 74 % in the past 3 years. Econometric results revealed that climate variables significantly influenced the supply reliability of surface water irrigation. Specifically, temperature is negatively related with the supply reliability of surface water irrigation; but precipitation positively influences the supply reliability of surface water irrigation. Besides, climate influence differs by seasons. In a word, this paper improves our understanding of the impact of climate change on agriculture irrigation and water supply reliability in the micro scale, and provides a scientific basis for relevant policy making.
NASA Technical Reports Server (NTRS)
Dempsey, Bert J.; Weaver, Alfred C.
1990-01-01
Multicast services needed for current distributed applications on LAN's fall generally into one of three categories: datagram, semi-reliable, and reliable. Transport layer multicast datagrams represent unreliable service in which the transmitting context 'fires and forgets'. XTP executes these semantics when the MULTI and NOERR mode bits are both set. Distributing sensor data and other applications in which application-level error recovery strategies are appropriate benefit from the efficiency in multidestination delivery offered by datagram service. Semi-reliable service refers to multicasting in which the control algorithms of the transport layer--error, flow, and rate control--are used in transferring the multicast distribution to the set of receiving contexts, the multicast group. The multicast defined in XTP provides semi-reliable service. Since, under a semi-reliable service, joining a multicast group means listening on the group address and entails no coordination with other members, a semi-reliable facility can be used for communication between a client and a server group as well as true peer-to-peer group communication. Resource location in a LAN is an important application domain. The term 'semi-reliable' refers to the fact that group membership changes go undetected. No attempt is made to assess the current membership of the group at any time--before, during, or after--the data transfer.
Ganasegeran, Kurubaran; Selvaraj, Kamaraj; Rashid, Abdul
2017-01-01
Background The six item Confusion, Hubbub and Order Scale (CHAOS-6) has been validated as a reliable tool to measure levels of household disorder. We aimed to investigate the goodness of fit and reliability of a new Malay version of the CHAOS-6. Methods The original English version of the CHAOS-6 underwent forward-backward translation into the Malay language. The finalised Malay version was administered to 105 myocardial infarction survivors in a Malaysian cardiac health facility. We performed confirmatory factor analyses (CFAs) using structural equation modelling. A path diagram and fit statistics were yielded to determine the Malay version’s validity. Composite reliability was tested to determine the scale’s reliability. Results All 105 myocardial infarction survivors participated in the study. The CFA yielded a six-item, one-factor model with excellent fit statistics. Composite reliability for the single factor CHAOS-6 was 0.65, confirming that the scale is reliable for Malay speakers. Conclusion The Malay version of the CHAOS-6 was reliable and showed the best fit statistics for our study sample. We thus offer a simple, brief, validated, reliable and novel instrument to measure chaos, the Skala Kecelaruan, Keriuhan & Tertib Terubahsuai (CHAOS-6), for the Malaysian population. PMID:28951688
Lesage, A D; Cyr, M; Toupin, J; Cormier, H; Valiquette, C
1991-01-01
Interview questionnaires offer more validity than self-administered format in exploring psychopathological or psychosocial phenomena of interest in psychiatric research. If used, special care needs to be paid to interviewers' training and ensuring that they maintain their reliability. No widespread training standards exist and each schedule may carry its own procedure. Our aims are to indicate how we trained interviewers with the French version of the Present State Examination (Wing, Cooper and Sartorius, 1974) and how we checked and kept acceptable interraters reliability during one study. We will provide data on the interraters reliability during the training and the study, as well as the test-retest reliability. These results will be used to support some guidelines when using this sort of psychiatric research questionnaires in order to ensure comparability both within the study and between studies.
RELIABILITY OF BIOMARKERS OF PESTICIDE EXPOSURE AMONG CHILDREN AND ADULTS IN CTEPP OHIO
Urinary biomarkers offer the potential for providing an efficient tool for exposure classification by reflecting the aggregate of all exposure routes. Substantial variability observed in urinary pesticide metabolite concentrations over short periods of time, however, has cast so...
Applications of Microcomputers in Patient Care
Eden, Henry S.
1979-01-01
This paper serves as an introduction to two sessions on microcomputer applications in patient care. It describes several advantages offered by microcomputers in the design of medical devices--flexibility, reliability, smallness, and low power consumption. It concludes by discussing eight categories of microcomputer application.
Public spending and NHS finance.
Jones, T
1992-10-01
Reliability, the Chancellor's Autumn Statement on the country's economic prospects, and the Government's public spending plans seldom go hand in hand. Last year's statement, however, offers an insight into this year's discussions and negotiations and their effect on NHS resources. Tom Jones sets the scene.
Field reliability of competency and sanity opinions: A systematic review and meta-analysis.
Guarnera, Lucy A; Murrie, Daniel C
2017-06-01
We know surprisingly little about the interrater reliability of forensic psychological opinions, even though courts and other authorities have long called for known error rates for scientific procedures admitted as courtroom testimony. This is particularly true for opinions produced during routine practice in the field, even for some of the most common types of forensic evaluations-evaluations of adjudicative competency and legal sanity. To address this gap, we used meta-analytic procedures and study space methodology to systematically review studies that examined the interrater reliability-particularly the field reliability-of competency and sanity opinions. Of 59 identified studies, 9 addressed the field reliability of competency opinions and 8 addressed the field reliability of sanity opinions. These studies presented a wide range of reliability estimates; pairwise percentage agreements ranged from 57% to 100% and kappas ranged from .28 to 1.0. Meta-analytic combinations of reliability estimates obtained by independent evaluators returned estimates of κ = .49 (95% CI: .40-.58) for competency opinions and κ = .41 (95% CI: .29-.53) for sanity opinions. This wide range of reliability estimates underscores the extent to which different evaluation contexts tend to produce different reliability rates. Unfortunately, our study space analysis illustrates that available field reliability studies typically provide little information about contextual variables crucial to understanding their findings. Given these concerns, we offer suggestions for improving research on the field reliability of competency and sanity opinions, as well as suggestions for improving reliability rates themselves. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Novel model of stator design to reduce the mass of superconducting generators
NASA Astrophysics Data System (ADS)
Kails, Kevin; Li, Quan; Mueller, Markus
2018-05-01
High temperature superconductors (HTS), with much higher current density than conventional copper wires, make it feasible to develop very powerful and compact power generators. Thus, they are considered as one promising solution for large (10 + MW) direct-drive offshore wind turbines due to their low tower head mass. However, most HTS generator designs are based on a radial topology, which requires an excessive amount of HTS material and suffers from cooling and reliability issues. Axial flux machines on the other hand offer higher torque/volume ratios than the radial machines, which makes them an attractive option where space and transportation becomes an issue. However, their disadvantage is heavy structural mass. In this paper a novel stator design is introduced for HTS axial flux machines which enables a reduction in their structural mass. The stator is for the first time designed with a 45° angle that deviates the air gap closing forces into the vertical direction reducing the axial forces. The reduced axial forces improve the structural stability and consequently simplify their structural design. The novel methodology was then validated through an existing design of the HTS axial flux machine achieving a ∼10% mass reduction from 126 tonnes down to 115 tonnes. In addition, the air gap flux density increases due to the new claw pole shapes improving its power density from 53.19 to 61.90 W kg‑1. It is expected that the HTS axial flux machines designed with the new methodology offer a competitive advantage over other proposed superconducting generator designs in terms of cost, reliability and power density.
DNA Microarray Wet Lab Simulation Brings Genomics into the High School Curriculum
Zanta, Carolyn A.; Heyer, Laurie J.; Kittinger, Ben; Gabric, Kathleen M.; Adler, Leslie
2006-01-01
We have developed a wet lab DNA microarray simulation as part of a complete DNA microarray module for high school students. The wet lab simulation has been field tested with high school students in Illinois and Maryland as well as in workshops with high school teachers from across the nation. Instead of using DNA, our simulation is based on pH indicators, which offer many ideal teaching characteristics. The simulation requires no specialized equipment, is very inexpensive, is very reliable, and takes very little preparation time. Student and teacher assessment data indicate the simulation is popular with both groups, and students show significant learning gains. We include many resources with this publication, including all prelab introductory materials (e.g., a paper microarray activity), the student handouts, teachers notes, and pre- and postassessment tools. We did not test the simulation on other student populations, but based on teacher feedback, the simulation also may fit well in community college and in introductory and nonmajors' college biology curricula. PMID:17146040
High-Temperature, Wirebondless, Ultracompact Wide Bandgap Power Semiconductor Modules
NASA Technical Reports Server (NTRS)
Elmes, John
2015-01-01
Silicon carbide (SiC) and other wide bandgap semiconductors offer great promise of high power rating, high operating temperature, simple thermal management, and ultrahigh power density for both space and commercial power electronic systems. However, this great potential is seriously limited by the lack of reliable high-temperature device packaging technology. This Phase II project developed an ultracompact hybrid power module packaging technology based on the use of double lead frames and direct lead frame-to-chip transient liquid phase (TLP) bonding that allows device operation up to 450 degC. The new power module will have a very small form factor with 3-5X reduction in size and weight from the prior art, and it will be capable of operating from 450 degC to -125 degC. This technology will have a profound impact on power electronics and energy conversion technologies and help to conserve energy and the environment as well as reduce the nation's dependence on fossil fuels.
Museum genomics: low-cost and high-accuracy genetic data from historical specimens.
Rowe, Kevin C; Singhal, Sonal; Macmanes, Matthew D; Ayroles, Julien F; Morelli, Toni Lyn; Rubidge, Emily M; Bi, Ke; Moritz, Craig C
2011-11-01
Natural history collections are unparalleled repositories of geographical and temporal variation in faunal conditions. Molecular studies offer an opportunity to uncover much of this variation; however, genetic studies of historical museum specimens typically rely on extracting highly degraded and chemically modified DNA samples from skins, skulls or other dried samples. Despite this limitation, obtaining short fragments of DNA sequences using traditional PCR amplification of DNA has been the primary method for genetic study of historical specimens. Few laboratories have succeeded in obtaining genome-scale sequences from historical specimens and then only with considerable effort and cost. Here, we describe a low-cost approach using high-throughput next-generation sequencing to obtain reliable genome-scale sequence data from a traditionally preserved mammal skin and skull using a simple extraction protocol. We show that single-nucleotide polymorphisms (SNPs) from the genome sequences obtained independently from the skin and from the skull are highly repeatable compared to a reference genome. © 2011 Blackwell Publishing Ltd.
DNA microarray wet lab simulation brings genomics into the high school curriculum.
Campbell, A Malcolm; Zanta, Carolyn A; Heyer, Laurie J; Kittinger, Ben; Gabric, Kathleen M; Adler, Leslie; Schulz, Barbara
2006-01-01
We have developed a wet lab DNA microarray simulation as part of a complete DNA microarray module for high school students. The wet lab simulation has been field tested with high school students in Illinois and Maryland as well as in workshops with high school teachers from across the nation. Instead of using DNA, our simulation is based on pH indicators, which offer many ideal teaching characteristics. The simulation requires no specialized equipment, is very inexpensive, is very reliable, and takes very little preparation time. Student and teacher assessment data indicate the simulation is popular with both groups, and students show significant learning gains. We include many resources with this publication, including all prelab introductory materials (e.g., a paper microarray activity), the student handouts, teachers notes, and pre- and postassessment tools. We did not test the simulation on other student populations, but based on teacher feedback, the simulation also may fit well in community college and in introductory and nonmajors' college biology curricula.
Innovative optronics for the new PUMA tank
NASA Astrophysics Data System (ADS)
Fritze, J.; Münzberg, M.; Schlemmer, H.
2010-04-01
The new PUMA tank is equipped with a fully stabilized 360° periscope. The thermal imager in the periscope is identical to the imager in the gunner sight. All optronic images of the cameras can be fed on every electronic display within the tank. The thermal imagers operate with a long wave 384x288 MCT starring focal plane array. The high quantum efficiency of MCT provides low NETD values at short integration times. The thermal imager has an image resolution of 768x576 pixels by means of a micro scanner. The MCT detector operates at high temperatures above 75K with high stability in noise and correctibility and offers high reliability (MTTF) values for the complete camera in a very compact design. The paper discusses the principle and functionality of the optronic combination of direct view optical channel, thermal imager and visible camera and discusses in detail the performances of the subcomponents with respect to demands for new tank applications.
NASA Technical Reports Server (NTRS)
Liebert, B. E.
1986-01-01
A metal-hydride heat pump (HHP) has been proposed to provide an advanced regenerable nonventing thermal sink for the liquid-cooled garment worn during an extravehicular activity (EVA). The conceptual design indicates that there is a potential for significant advantages over the one presently being used by shuttle crew personnel as well as those that have been proposed for future use with the space station. Compared to other heat pump designs, a HHP offers the potential for extended use with no electrical power requirements during the EVA. In addition, a reliable, compact design is possible due to the absence of moving parts other than high-reliability check valves. Because there are many subtleties in the properties of metal hydrides for heat pump applications, it is essential that a prototype hydride heat pump be constructed with the selected materials before a committment is made for the final design. Particular care must be given to the evaporator heat exchanger worn by the astronaut since the performance of hydride heat pumps is generally heat transfer limited.
Liu, Ren; Srivastava, Anurag K.; Bakken, David E.; ...
2017-08-17
Intermittency of wind energy poses a great challenge for power system operation and control. Wind curtailment might be necessary at the certain operating condition to keep the line flow within the limit. Remedial Action Scheme (RAS) offers quick control action mechanism to keep reliability and security of the power system operation with high wind energy integration. In this paper, a new RAS is developed to maximize the wind energy integration without compromising the security and reliability of the power system based on specific utility requirements. A new Distributed Linear State Estimation (DLSE) is also developed to provide the fast andmore » accurate input data for the proposed RAS. A distributed computational architecture is designed to guarantee the robustness of the cyber system to support RAS and DLSE implementation. The proposed RAS and DLSE is validated using the modified IEEE-118 Bus system. Simulation results demonstrate the satisfactory performance of the DLSE and the effectiveness of RAS. Real-time cyber-physical testbed has been utilized to validate the cyber-resiliency of the developed RAS against computational node failure.« less
NASA Astrophysics Data System (ADS)
Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.
2014-07-01
A reliable method of sample introduction is presented for on-line gas chromatography with a special application to in-situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a controlled pressure switching device that offers the advantage of long term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing the interface for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient detector and 15% accurate when applied to a vacuum based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show approximately three times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in-situ instrument demonstrate minimal trending and a zero failure rate during field deployments ranging up to four weeks of continuous sampling. Extension of the VLI to dual collection cells is presented with less than 3% cell-to-cell carry-over.
Hampicke, M; Schadow, B; Rossdeutscher, W; Fellbaum, K; Boenick, U
2002-11-01
Progress in microtechnology and radio transmission technology has enabled the development of highly reliable emergency-call systems. The present article describes systems that have been specially designed to improve the safety and independence of handicapped and elderly persons living at home. For such persons immediate help in an emergency situation is of crucial importance. The technical state of the art of emergency-call systems specially developed for use by the elderly, is briefly discussed, in particular the well-known radio emergency-call button, with the aid of which an alarm can be activated manually. This system, however, does not offer adequate safety in all emergency situations. Alternative or complementary systems designed to automatically trigger an alarm on the basis of the recording and evaluation of so-called vital parameters, are therefore proposed. In addition, in a smart-home environment with networked devices, further parameters--so-called environment parameters can be used. It is found that the identification of an emergency situation becomes more reliable as the number of parameters employed increases.
Patient's perceptions about the service quality of public hospitals located at District Kohat.
Aman, Bakhtiar; Abbas, Faisal
2016-01-01
To determine patients' perception regarding service and quality of healthcare at public-sector institutions. The descriptive quantitative study was conducted in Kohat district, Pakistan, between July and December 2014, and focussed on 30 variables to assess the participants' perceptions of the actual healthcare service quality delivered. SERVQUAL instrument was used to measure the reliability and cronbach alpha was calculated to measure the reliability and validity of the instrument. A total of 200 questionnaires were distributed and 157(78.5%) were received back fully filled. Of them, 105(67%) were men and 52(33%) were women.The mean value of Assurance parameter was 3.05±0.88, indicating trust in public hospitals was high as they had experienced and capable doctors. On the other hand, the lowest mean value of 2.61±0.84 was for Empathy, highlighting the fact that public hospitals lacked the ability to handle patients' problem properly, services were not offered in time and they were short of staff. Public hospitals were largely seen as failing to deliver quality service.
Electrochemical genosensors in food safety assessment.
Martín-Fernández, Begoña; Manzanares-Palenzuela, C Lorena; Sánchez-Paniagua López, Marta; de-Los-Santos-Álvarez, Noemí; López-Ruiz, Beatriz
2017-09-02
The main goal of food safety assessment is to provide reliable information on the identity and composition of food and reduce the presence of harmful components. Nowadays, there are many countries where rather than the presence of pathogens, common public concerns are focused on the presence of hidden allergens, fraudulent practices, and genetic modifications in food. Accordingly, food regulations attempt to offer a high level of protection and to guarantee transparent information to the consumers. The availability of analytical methods is essential to comply these requirements. Protein-based strategies are usually employed for this purpose, but present some limitations. Because DNA is a more stable molecule, present in most tissues, and can be amplified, there has been an increasing interest in developing DNA-based approaches (polymerase chain reaction, microarrays, and genosensors). In this regard, electrochemical genosensors may play a major role in fulfilling the needs of food industry, such as reliable, portable, and affordable devices. This work reviews the achievements of this technology applied to allergen detection, species identification, and genetically modified organisms testing. We summarized the legislative framework, current design strategies in sensor development, their analytical characteristics, and future prospects.
Using Pareto points for model identification in predictive toxicology
2013-01-01
Predictive toxicology is concerned with the development of models that are able to predict the toxicity of chemicals. A reliable prediction of toxic effects of chemicals in living systems is highly desirable in cosmetics, drug design or food protection to speed up the process of chemical compound discovery while reducing the need for lab tests. There is an extensive literature associated with the best practice of model generation and data integration but management and automated identification of relevant models from available collections of models is still an open problem. Currently, the decision on which model should be used for a new chemical compound is left to users. This paper intends to initiate the discussion on automated model identification. We present an algorithm, based on Pareto optimality, which mines model collections and identifies a model that offers a reliable prediction for a new chemical compound. The performance of this new approach is verified for two endpoints: IGC50 and LogP. The results show a great potential for automated model identification methods in predictive toxicology. PMID:23517649
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Ren; Srivastava, Anurag K.; Bakken, David E.
Intermittency of wind energy poses a great challenge for power system operation and control. Wind curtailment might be necessary at the certain operating condition to keep the line flow within the limit. Remedial Action Scheme (RAS) offers quick control action mechanism to keep reliability and security of the power system operation with high wind energy integration. In this paper, a new RAS is developed to maximize the wind energy integration without compromising the security and reliability of the power system based on specific utility requirements. A new Distributed Linear State Estimation (DLSE) is also developed to provide the fast andmore » accurate input data for the proposed RAS. A distributed computational architecture is designed to guarantee the robustness of the cyber system to support RAS and DLSE implementation. The proposed RAS and DLSE is validated using the modified IEEE-118 Bus system. Simulation results demonstrate the satisfactory performance of the DLSE and the effectiveness of RAS. Real-time cyber-physical testbed has been utilized to validate the cyber-resiliency of the developed RAS against computational node failure.« less
Methods for assessment of keel bone damage in poultry.
Casey-Trott, T; Heerkens, J L T; Petrik, M; Regmi, P; Schrader, L; Toscano, M J; Widowski, T
2015-10-01
Keel bone damage (KBD) is a critical issue facing the laying hen industry today as a result of the likely pain leading to compromised welfare and the potential for reduced productivity. Recent reports suggest that damage, while highly variable and likely dependent on a host of factors, extends to all systems (including battery cages, furnished cages, and non-cage systems), genetic lines, and management styles. Despite the extent of the problem, the research community remains uncertain as to the causes and influencing factors of KBD. Although progress has been made investigating these factors, the overall effort is hindered by several issues related to the assessment of KBD, including quality and variation in the methods used between research groups. These issues prevent effective comparison of studies, as well as difficulties in identifying the presence of damage leading to poor accuracy and reliability. The current manuscript seeks to resolve these issues by offering precise definitions for types of KBD, reviewing methods for assessment, and providing recommendations that can improve the accuracy and reliability of those assessments. © 2015 Poultry Science Association Inc.
Valid and Reliable Science Content Assessments for Science Teachers
NASA Astrophysics Data System (ADS)
Tretter, Thomas R.; Brown, Sherri L.; Bush, William S.; Saderholm, Jon C.; Holmes, Vicki-Lynn
2013-03-01
Science teachers' content knowledge is an important influence on student learning, highlighting an ongoing need for programs, and assessments of those programs, designed to support teacher learning of science. Valid and reliable assessments of teacher science knowledge are needed for direct measurement of this crucial variable. This paper describes multiple sources of validity and reliability (Cronbach's alpha greater than 0.8) evidence for physical, life, and earth/space science assessments—part of the Diagnostic Teacher Assessments of Mathematics and Science (DTAMS) project. Validity was strengthened by systematic synthesis of relevant documents, extensive use of external reviewers, and field tests with 900 teachers during assessment development process. Subsequent results from 4,400 teachers, analyzed with Rasch IRT modeling techniques, offer construct and concurrent validity evidence.
A comparison of four measures of moral reasoning.
Wilmoth, G H; McFarland, S G
1977-08-01
Kohlberg's Moral Judgment Scale, Gilligan et al.'s Sexual Moral Judgment Scale, Maitland and Goldman's Objective Moral Judgment Scale, and Hogan's Maturity of Moral Judgment Scale, were examined for reliability and inter-scale relationships. All measures except the Objective Moral Judgment Scale had good reliabilities. The obtained relations between the Moral Judgment Scale and the Sexual Moral Judgment Scale replicated previous research. The Objective Moral Judgment Scale was not found to validly assess the Kohlberg stages. The Maturity of Moral Judgment Scale scores were strongly related to the subjects's classification on the Kohlberg stages, and the scale appears to offer a reliable, quickly scored, and valid index of mature thought, although the scale's continuous scores do not permit clear stage classification.
A Meta-Analysis of the Reliability of Free and For-Pay Big Five Scales.
Hamby, Tyler; Taylor, Wyn; Snowden, Audrey K; Peterson, Robert A
2016-01-01
The present study meta-analytically compared coefficient alpha reliabilities reported for free and for-pay Big Five scales. We collected 288 studies from five previous meta-analyses of Big Five traits and harvested 1,317 alphas from these studies. We found that free and for-pay scales measuring Big Five traits possessed comparable reliabilities. However, after we controlled for the numbers of items in the scales with the Spearman-Brown formula, we found that free scales possessed significantly higher alpha coefficients than for-pay scales for each of the Big Five traits. Thus, the study offers initial evidence that Big Five scales that are free more efficiently measure these traits for research purposes than do for-pay scales.
A novel approach for reliable detection of cathepsin S activities in mouse antigen presenting cells.
Steimle, Alex; Kalbacher, Hubert; Maurer, Andreas; Beifuss, Brigitte; Bender, Annika; Schäfer, Andrea; Müller, Ricarda; Autenrieth, Ingo B; Frick, Julia-Stefanie
2016-05-01
Cathepsin S (CTSS) is a eukaryotic protease mostly expressed in professional antigen presenting cells (APCs). Since CTSS activity regulation plays a role in the pathogenesis of various autoimmune diseases like multiple sclerosis, atherosclerosis, Sjögren's syndrome and psoriasis as well as in cancer progression, there is an ongoing interest in the reliable detection of cathepsin S activity. Various applications have been invented for specific detection of this enzyme. However, most of them have only been shown to be suitable for human samples, do not deliver quantitative results or the experimental procedure requires technical equipment that is not commonly available in a standard laboratory. We have tested a fluorogen substrate, Mca-GRWPPMGLPWE-Lys(Dnp)-DArg-NH2, that has been described to specifically detect CTSS activities in human APCs for its potential use for mouse samples. We have modified the protocol and thereby offer a cheap, easy, reproducible and quick activity assay to detect CTSS activities in mouse APCs. Since most of basic research on CTSS is performed in mice, this method closes a gap and offers a possibility for reliable and quantitative CTSS activity detection that can be performed in almost every laboratory. Copyright © 2016. Published by Elsevier B.V.
Weir, David R.; Wallace, Robert B.; Langa, Kenneth M.; Plassman, Brenda L.; Wilson, Robert S.; Bennett, David A.; Duara, Ranjan; Loewenstein, David; Ganguli, Mary; Sano, Mary
2011-01-01
Establishing methods for ascertainment of dementia and cognitive impairment that are accurate and also cost effective is a challenging enterprise. Large population-based studies often using administrative data sets offer relatively inexpensive but reliable estimates of severe conditions including moderate to advanced dementia that are useful for public health planning, but they can miss less severe cognitive impairment which may be the most effective point for intervention. Clinical and epidemiological cohorts, intensively assessed, provide more sensitive detection of less severe cognitive impairment but are often costly. Here, several approaches to ascertainment are evaluated for validity, reliability, and cost. In particular, the methods of ascertainment from the Health and Retirement Study (HRS) are described briefly, along with those of the Aging, Demographics, and Memory Study (ADAMS). ADAMS, a resource-intense sub-study of the HRS, was designed to provide diagnostic accuracy among persons with more advanced dementia. A proposal to streamline future ADAMS assessments is offered. Also considered are decision tree, algorithmic, and web-based approaches to diagnosis that can reduce the expense of clinical expertise and, in some contexts, can reduce the extent of data collection. These approaches are intended for intensively assessed epidemiological cohorts. The goal is valid and reliable detection with efficient and cost-effective tools. PMID:21255747
Better Minds, Better Morals: A Procedural Guide to Better Judgment
Schaefer, G. Owen; Savulescu, Julian
2017-01-01
Making more moral decisions – an uncontroversial goal, if ever there was one. But how to go about it? In this article, we offer a practical guide on ways to promote good judgment in our personal and professional lives. We will do this not by outlining what the good life consists in or which values we should accept.Rather, we offer a theory of procedural reliability: a set of dimensions of thought that are generally conducive to good moral reasoning. At the end of the day, we all have to decide for ourselves what is good and bad, right and wrong. The best way to ensure we make the right choices is to ensure the procedures we’re employing are sound and reliable. We identify four broad categories of judgment to be targeted – cognitive, self-management, motivational and interpersonal. Specific factors within each category are further delineated, with a total of 14 factors to be discussed. For each, we will go through the reasons it generally leads to more morally reliable decision-making, how various thinkers have historically addressed the topic, and the insights of recent research that can offer new ways to promote good reasoning. The result is a wide-ranging survey that contains practical advice on how to make better choices. Finally, we relate this to the project of transhumanism and prudential decision-making. We argue that transhumans will employ better moral procedures like these. We also argue that the same virtues will enable us to take better control of our own lives, enhancing our responsibility and enabling us to lead better lives from the prudential perspective. PMID:29098205
2011-01-01
Background Fibromyalgia (FM) is a complex syndrome that affects many aspects of the patients life and it is very difficult to evaluate in clinical practice. A recent study has developed the Combined Index of Severity of Fibromyalgia (ICAF), an instrument that evaluates diverse aspects of FM and offers five indices: emotional, physical, active coping, passive coping and total. The objective of this study is to confirm the structure of the ICAF, check its test-retest reliability, assess its sensitivity to change, and compare the results obtained in a sample of patients with fibromyalgia with another sample of healthy controls. Methods A total of 232 patients took part in the study, 228 women and 4 men, with a mean age of 47.73 years of age (SD = 8.61) and a time of disease evolution since diagnosis of 4.28 years (SD = 4.03). The patients from the FM group completed the ICAF. Between one and two weeks later, they again attended the clinic and complete the 59 items on the ICAF (retest) and immediately afterwards they began treatment (according to daily clinical practice criteria). A sample of healthy subjects was also studied as a control group: 110 people were included (106 women and 4 men) with a mean age of 46.01 years of age (SD = 9.35). The study was conducted in Spain. Results The results obtained suggest that the four-factor model obtained in the previous study adequately fits the data obtained in this study. The test-retest reliability and internal consistency were all significant and show a high degree of correlation for all the factors as well as in overall score. With the exception of the passive coping factor, all the other scores, including the overall score, were sensitive to change after the therapeutic intervention. The ICAF scores of the patients with fibromyalgia compared with those of the control group were markedly different. Conclusions The findings suggest that the ICAF is a valid, reliable, sensitive to change instrument with the added advantage that it offers some additional domains (factors) that provide very valuable information regarding the most delicate aspects of the patient, which must be addressed at the time of treatment in daily clinical practice. PMID:21649886
Vallejo, Miguel A; Rivera, Javier; Esteve-Vives, Joaquim; Rejas, Javier
2011-06-07
Fibromyalgia (FM) is a complex syndrome that affects many aspects of the patient's life and it is very difficult to evaluate in clinical practice. A recent study has developed the Combined Index of Severity of Fibromyalgia (ICAF), an instrument that evaluates diverse aspects of FM and offers five indices: emotional, physical, active coping, passive coping and total. The objective of this study is to confirm the structure of the ICAF, check its test-retest reliability, assess its sensitivity to change, and compare the results obtained in a sample of patients with fibromyalgia with another sample of healthy controls. A total of 232 patients took part in the study, 228 women and 4 men, with a mean age of 47.73 years of age (SD = 8.61) and a time of disease evolution since diagnosis of 4.28 years (SD = 4.03). The patients from the FM group completed the ICAF. Between one and two weeks later, they again attended the clinic and complete the 59 items on the ICAF (retest) and immediately afterwards they began treatment (according to daily clinical practice criteria). A sample of healthy subjects was also studied as a control group: 110 people were included (106 women and 4 men) with a mean age of 46.01 years of age (SD = 9.35). The study was conducted in Spain. The results obtained suggest that the four-factor model obtained in the previous study adequately fits the data obtained in this study. The test-retest reliability and internal consistency were all significant and show a high degree of correlation for all the factors as well as in overall score. With the exception of the passive coping factor, all the other scores, including the overall score, were sensitive to change after the therapeutic intervention. The ICAF scores of the patients with fibromyalgia compared with those of the control group were markedly different. The findings suggest that the ICAF is a valid, reliable, sensitive to change instrument with the added advantage that it offers some additional domains (factors) that provide very valuable information regarding the most delicate aspects of the patient, which must be addressed at the time of treatment in daily clinical practice.
New Directions in Nicotine Vaccine Design and Use
Pentel, Paul R.; LeSage, Mark G.
2014-01-01
Clinical trials of nicotine vaccines suggest that they can enhance smoking cessation rates but do not reliably produce the consistently high serum antibody concentrations required. A wide array of next-generation strategies are being evaluated to enhance vaccine efficacy or provide antibody through other mechanisms. Protein conjugate vaccines may be improved by modifications of hapten or linker design or by optimizing hapten density. Conjugating hapten to viruslike particles or disrupted virus may allow exploitation of naturally occurring viral features associated with high immunogenicity. Conjugates that utilize different linker positions on nicotine can function as independent immunogens, so that using them in combination generates higher antibody concentrations than can be produced by a single immunogen. Nanoparticle vaccines, consisting of hapten, T cell help peptides, and adjuvants attached to a liposome or synthetic scaffold, are in the early stages of development. Nanoparticle vaccines offer the possibility of obtaining precise and consistent control of vaccine component stoichiometry and spacing and immunogen size and shape. Passive transfer of nicotine-specific monoclonal antibodies offers a greater control of antibody dose, the ability to give very high doses, and an immediate onset of action but is expensive and has a shorter duration of action than vaccines. Viral vector-mediated transfer of genes for antibody production can elicit high levels of antibody expression in animals and may present an alternative to vaccination or passive immunization if the long-term safety of this approach is confirmed. Next-generation immunotherapies are likely to be substantially more effective than first-generation vaccines. PMID:24484987
Corbellini, Carlo; Andreoni, Bruno; Ansaloni, Luca; Sgroi, Giovanni; Martinotti, Mario; Scandroglio, Ildo; Carzaniga, Pierluigi; Longoni, Mauro; Foschi, Diego; Dionigi, Paolo; Morandi, Eugenio; Agnello, Mauro
2018-01-01
Measurement and monitoring of the quality of care using a core set of quality measures are increasing in health service research. Although administrative databases include limited clinical data, they offer an attractive source for quality measurement. The purpose of this study, therefore, was to evaluate the completeness of different administrative data sources compared to a clinical survey in evaluating rectal cancer cases. Between May 2012 and November 2014, a clinical survey was done on 498 Lombardy patients who had rectal cancer and underwent surgical resection. These collected data were compared with the information extracted from administrative sources including Hospital Discharge Dataset, drug database, daycare activity data, fee-exemption database, and regional screening program database. The agreement evaluation was performed using a set of 12 quality indicators. Patient complexity was a difficult indicator to measure for lack of clinical data. Preoperative staging was another suboptimal indicator due to the frequent missing administrative registration of tests performed. The agreement between the 2 data sources regarding chemoradiotherapy treatments was high. Screening detection, minimally invasive techniques, length of stay, and unpreventable readmissions were detected as reliable quality indicators. Postoperative morbidity could be a useful indicator but its agreement was lower, as expected. Healthcare administrative databases are large and real-time collected repositories of data useful in measuring quality in a healthcare system. Our investigation reveals that the reliability of indicators varies between them. Ideally, a combination of data from both sources could be used in order to improve usefulness of less reliable indicators.
Stoyanova, Rumyana; Dimova, Rositsa; Tarnovska, Miglena; Boeva, Tatyana
2018-05-20
Patient safety (PS) is one of the essential elements of health care quality and a priority of healthcare systems in most countries. Thus the creation of validated instruments and the implementation of systems that measure patient safety are considered to be of great importance worldwide. The present paper aims to illustrate the process of linguistic validation, cross-cultural verification and adaptation of the Bulgarian version of the Hospital Survey on Patient Safety Culture (B-HSOPSC) and its test-retest reliability. The study design is cross-sectional. The HSOPSC questionnaire consists of 42 questions, grouped in 12 different subscales that measure patient safety culture. Internal con-sistency was assessed using Cronbach's alpha. The Wilcoxon signed-rank test and the split-half method were used; the Spear-man-Brown coefficient was calculated. The overall Cronbach's alpha for B-HSOPSC is 0.918. Subscales 7 Staffing and 12 Overall perceptions of safety had the lowest coefficients. The high reliability of the instrument was confirmed by the Split-half method (0.97) and ICC-coefficient (0.95). The lowest values of Spearmen-Broun coefficients were found in items A13 and A14. The study offers an analysis of the results of the linguistic validation of the B-HSOPSC and its test-retest reliability. The psychometric characteristics of the questions revealed good validity and reliability, except two questions. In the future, the instrument will be administered to the target population in the main study so that the psychometric properties of the instrument can be verified.
NASA Astrophysics Data System (ADS)
Sofia, G.; Tarolli, P.; Dalla Fontana, G.
2012-04-01
In floodplains, massive investments in land reclamation have always played an important role in the past for flood protection. In these contexts, human alteration is reflected by artificial features ('Anthropogenic features'), such as banks, levees or road scarps, that constantly increase and change, in response to the rapid growth of human populations. For these areas, various existing and emerging applications require up-to-date, accurate and sufficiently attributed digital data, but such information is usually lacking, especially when dealing with large-scale applications. More recently, National or Local Mapping Agencies, in Europe, are moving towards the generation of digital topographic information that conforms to reality and are highly reliable and up to date. LiDAR Digital Terrain Models (DTMs) covering large areas are readily available for public authorities, and there is a greater and more widespread interest in the application of such information by agencies responsible for land management for the development of automated methods aimed at solving geomorphological and hydrological problems. Automatic feature recognition based upon DTMs can offer, for large-scale applications, a quick and accurate method that can help in improving topographic databases, and that can overcome some of the problems associated with traditional, field-based, geomorphological mapping, such as restrictions on access, and constraints of time or costs. Although anthropogenic features as levees and road scarps are artificial structures that actually do not belong to what is usually defined as the bare ground surface, they are implicitly embedded in digital terrain models (DTMs). Automatic feature recognition based upon DTMs, therefore, can offer a quick and accurate method that does not require additional data, and that can help in improving flood defense asset information, flood modeling or other applications. In natural contexts, morphological indicators derived from high resolution topography have been proven to be reliable for feasible applications. The use of statistical operators as thresholds for these geomorphic parameters, furthermore, showed a high reliability for feature extraction in mountainous environments. The goal of this research is to test if these morphological indicators and objective thresholds can be feasible also in floodplains, where features assume different characteristics and other artificial disturbances might be present. In the work, three different geomorphic parameters are tested and applied at different scales on a LiDAR DTM of typical alluvial plain's area in the North East of Italy. The box-plot is applied to identify the threshold for feature extraction, and a filtering procedure is proposed, to improve the quality of the final results. The effectiveness of the different geomorphic parameters is analyzed, comparing automatically derived features with the surveyed ones. The results highlight the capability of high resolution topography, geomorphic indicators and statistical thresholds for anthropogenic features extraction and characterization in a floodplains context.
REFMAC5 for the refinement of macromolecular crystal structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murshudov, Garib N., E-mail: garib@ysbl.york.ac.uk; Skubák, Pavol; Lebedev, Andrey A.
The general principles behind the macromolecular crystal structure refinement program REFMAC5 are described. This paper describes various components of the macromolecular crystallographic refinement program REFMAC5, which is distributed as part of the CCP4 suite. REFMAC5 utilizes different likelihood functions depending on the diffraction data employed (amplitudes or intensities), the presence of twinning and the availability of SAD/SIRAS experimental diffraction data. To ensure chemical and structural integrity of the refined model, REFMAC5 offers several classes of restraints and choices of model parameterization. Reliable models at resolutions at least as low as 4 Å can be achieved thanks to low-resolution refinement toolsmore » such as secondary-structure restraints, restraints to known homologous structures, automatic global and local NCS restraints, ‘jelly-body’ restraints and the use of novel long-range restraints on atomic displacement parameters (ADPs) based on the Kullback–Leibler divergence. REFMAC5 additionally offers TLS parameterization and, when high-resolution data are available, fast refinement of anisotropic ADPs. Refinement in the presence of twinning is performed in a fully automated fashion. REFMAC5 is a flexible and highly optimized refinement package that is ideally suited for refinement across the entire resolution spectrum encountered in macromolecular crystallography.« less
Student Portfolios: A Collection of Articles.
ERIC Educational Resources Information Center
Fogarty, Robin, Ed.
More and more, schools are looking to student portfolios as a valid, reliable, and authentic form of assessment. This collection offers practical, well-researched answers to a variety of philosophical, organizational, and implementational questions surrounding portfolio assessment. Articles in the first section provide a rationale for student…
Jiang, Zhehan; Skorupski, William
2017-12-12
In many behavioral research areas, multivariate generalizability theory (mG theory) has been typically used to investigate the reliability of certain multidimensional assessments. However, traditional mG-theory estimation-namely, using frequentist approaches-has limits, leading researchers to fail to take full advantage of the information that mG theory can offer regarding the reliability of measurements. Alternatively, Bayesian methods provide more information than frequentist approaches can offer. This article presents instructional guidelines on how to implement mG-theory analyses in a Bayesian framework; in particular, BUGS code is presented to fit commonly seen designs from mG theory, including single-facet designs, two-facet crossed designs, and two-facet nested designs. In addition to concrete examples that are closely related to the selected designs and the corresponding BUGS code, a simulated dataset is provided to demonstrate the utility and advantages of the Bayesian approach. This article is intended to serve as a tutorial reference for applied researchers and methodologists conducting mG-theory studies.
Howard, Steven J.; Melhuish, Edward
2016-01-01
Several methods of assessing executive function (EF), self-regulation, language development, and social development in young children have been developed over previous decades. Yet new technologies make available methods of assessment not previously considered. In resolving conceptual and pragmatic limitations of existing tools, the Early Years Toolbox (EYT) offers substantial advantages for early assessment of language, EF, self-regulation, and social development. In the current study, results of our large-scale administration of this toolbox to 1,764 preschool and early primary school students indicated very good reliability, convergent validity with existing measures, and developmental sensitivity. Results were also suggestive of better capture of children’s emerging abilities relative to comparison measures. Preliminary norms are presented, showing a clear developmental trajectory across half-year age groups. The accessibility of the EYT, as well as its advantages over existing measures, offers considerably enhanced opportunities for objective measurement of young children’s abilities to enable research and educational applications. PMID:28503022
Moral-Muñoz, José A; Esteban-Moreno, Bernabé; Arroyo-Morales, Manuel; Cobo, Manuel J; Herrera-Viedma, Enrique
2015-09-01
The objective of this study was to determine the level of agreement between face-to-face hamstring flexibility measurements and free software video analysis in adolescents. Reduced hamstring flexibility is common in adolescents (75% of boys and 35% of girls aged 10). The length of the hamstring muscle has an important role in both the effectiveness and the efficiency of basic human movements, and reduced hamstring flexibility is related to various musculoskeletal conditions. There are various approaches to measuring hamstring flexibility with high reliability; the most commonly used approaches in the scientific literature are the sit-and-reach test, hip joint angle (HJA), and active knee extension. The assessment of hamstring flexibility using video analysis could help with adolescent flexibility follow-up. Fifty-four adolescents from a local school participated in a descriptive study of repeated measures using a crossover design. Active knee extension and HJA were measured with an inclinometer and were simultaneously recorded with a video camera. Each video was downloaded to a computer and subsequently analyzed using Kinovea 0.8.15, a free software application for movement analysis. All outcome measures showed reliability estimates with α > 0.90. The lowest reliability was obtained for HJA (α = 0.91). The preliminary findings support the use of a free software tool for assessing hamstring flexibility, offering health professionals a useful tool for adolescent flexibility follow-up.
Development of a water-escape motivated version of the Stone T-maze for mice
Pistell, Paul J.; Ingram, Donald K.
2014-01-01
Mice provide a highly valuable resource for investigating learning and memory processes; however, many of the established tasks for evaluating learning and memory were developed for rats. Behaviors of mice in these tasks appear to be driven by different motivational factors, and as a result, they often do not perform reliably on tasks involving rewards traditionally used for rats. Because of difficulties in measuring learning and memory in mice as well as the need to have a task that can reliably measure these behavioral processes, we have developed a mouse version of the Stone T-maze utilizing what appears to be the primary motivation of mice, escape to a safe location. Specifically, we have constructed a task that requires the mouse to wade through water to reach a dark and dry goal box. To escape this aversive environment, the Stone T-maze requires learning the correct sequence of 13 left and right turns to reach the goal box. Through a series of experiments examining a variety of protocols, it was found that mice will reliably perform this task. This task can be used to assess learning and memory without the potential performance confounds that can affect performance of mice in other tasks. We believe this task offers a valuable new tool for evaluating learning and memory in mice not previously available to researchers. PMID:20026250
NASA Technical Reports Server (NTRS)
Hurlbert, Eric; Morehead, Robert; Melcher, John C.; Atwell, Matt
2016-01-01
An integrated liquid oxygen (LOx) and methane propulsion system where common propellants are fed to the reaction control system and main engines offers advantages in performance, simplicity, reliability, and reusability. LOx/Methane provides new capabilities to use propellants that are manufactured on the Mars surface for ascent return and to integrate with power and life support systems. The clean burning, non-toxic, high vapor pressure propellants provide significant advantages for reliable ignition in a space vacuum, and for reliable safing or purging of a space-based vehicle. The NASA Advanced Exploration Systems (AES) Morpheus lander demonstrated many of these key attributes as it completed over 65 tests including 15 flights through 2014. Morpheus is a prototype of LOx/Methane propellant lander vehicle with a fully integrated propulsion system. The Morpheus lander flight demonstrations led to the proposal to use LOx/Methane for a Discovery class mission, named Moon Aging Regolith Experiment (MARE) to land an in-situ science payload for Southwest Research Institute on the Lunar surface. Lox/Methane is extensible to human spacecraft for many transportation elements of a Mars architecture. This paper discusses LOx/Methane propulsion systems in regards to trade studies, the Morpheus project experience, the MARE NAVIS (NASA Autonomous Vehicle for In-situ Science) lander, and future possible applications. The paper also discusses technology research and development needs for Lox/Methane propulsion systems.
A validated pediatric transport survey: how is your team performing?
McPherson, Mona L; Jefferson, Larry S; Graf, Jeanine M
2008-01-01
Understanding referring practitioners' satisfaction with pediatric transport services is useful for quality improvement. Formal survey methodology was applied to develop a pediatric transport satisfaction survey. Large metropolitan area in the Southwestern United States. A four-stage process was used to create a 20-item pediatric transport satisfaction survey. The final survey was analyzed for test-retest and internal consistency reliability, and surveys were mailed to a large practitioner base. The survey encompassed three domains: patient care, accessing the transport system, and communication. Test-retest and internal consistency reliability were good (final Cronbach alpha coefficient of 0.88.) Of the 229 providers responding, 69% were local (<60 miles), and 31% were served by our long distance transport team (>60 miles). Respondents reported that physicians selected the transport team in 82% of cases, whereas 9% reported that the charge nurse decided. Transport team selection was based on: (1) ease of initiation, (2) fastest arrival, (3) presence of a physician on the team, (4) stabilization time at the referring facility, and (5) team providing best follow-up. Satisfaction with our transport service was high, with a median survey score of 83 (interquartile [IQ] range, 74-92). Physicians and nurses reported equal satisfaction. Survey design methodology was successfully applied to assess satisfaction with pediatric transport. This transport survey offers a reliable measurement of providers' satisfaction with transport services.
Development and validation of the client engagement and service use scale: A pilot study.
Kline, Emily R; DeTore, Nicole R; Keefe, Kristen; Seidman, Larry J; Srihari, Vinod H; Keshavan, Matcheri S; Guyer, Margaret
2018-05-12
Specialized treatment for first episode psychosis offers clients a menu of services coordinated within a specialized treatment team. To enhance the impact of these services, promoting engagement and preventing early treatment drop-out is critical. However, engagement is poorly tracked and typically quantified through proxy variables such as session attendance, medication adherence, or working alliance. The aim of this study is to introduce and pilot a new measure of engagement for first episode psychosis coordinated specialty care, the Client Engagement and Service Use Scale (CENSUS). The CENSUS was evaluated for reliability and validated against the Service Engagement Scale and an appointment count for a small sample (N = 10) of first episode clients. The measure was also evaluated for acceptability by a consumer advocacy group. Clinicians achieved high inter-rater reliability after minimal training. CENSUS items demonstrated medium to large correlations with other measures of engagement. Feedback from the consumer group emphasized that clinicians should ask questions in a way that is nonjudgmental and successfully elicits authentic client feedback about their service preferences. This pilot study yielded preliminary evidence of reliability and validity, suggesting that the CENSUS is a useful and novel tool for tracking and differentiating degrees of client engagement across multiple intervention components and for facilitating structured discussions regarding clients' service utilization and preferences. Copyright © 2018. Published by Elsevier B.V.
Navarro, Aaron; Martínez-Murcia, Antonio
2018-04-19
The phylogenies derived from housekeeping gene sequence alignments, although mere evolutionary hypotheses, have increased our knowledge about the Aeromonas genetic diversity, providing a robust species delineation framework invaluable for reliable, easy and fast species identification. Previous classifications of Aeromonas, have been fully surpassed by recently developed phylogenetic (natural) classification obtained from the analysis of so-called "molecular chronometers". Despite ribosomal RNAs cannot split all known Aeromonas species, the conserved nature of 16S rRNA offers reliable alignments containing mosaics of sequence signatures which may serve as targets of genus-specific oligonucleotides for subsequent identification/detection tests in samples without culturing. On the contrary, some housekeeping genes coding for proteins show a much better chronometric capacity to discriminate highly related strains. Although both, species and loci, do not all evolve at exactly the same rate, published Aeromonas phylogenies were congruent to each other, indicating that, phylogenetic markers are synchronized and a concatenated multi-gene phylogeny, may be "the mirror" of the entire genomic relationships. Thanks to MLPA approaches, the discovery of new Aeromonas species and strains of rarely isolated species is today more frequent and, consequently, should be extensively promoted for isolate screening and species identification. Although, accumulated data still should be carefully catalogued to inherit a reliable database. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
NASA Technical Reports Server (NTRS)
Heyman, Joseph S.
1993-01-01
Pump uses acoustic-radiation forces. Momentum transferred from sound waves to sound-propagating material in way resulting in net pumping action on material. Acoustic pump is solid-state pump. Requires no moving parts, entirely miniaturized, and does not invade pumped environment. Silent, with no conventional vibration. Used as pump for liquid, suspension, gas, or any other medium interacting with radiation pressure. Also used where solid-state pump needed for reliability and controllability. In microgravity environment, device offers unusual control for low flow rates. For medical or other applications in which contamination cannot be allowed, offers noninvasive pumping force.
Whole genome sequencing in the prevention and control of Staphylococcus aureus infection.
Price, J R; Didelot, X; Crook, D W; Llewelyn, M J; Paul, J
2013-01-01
Staphylococcus aureus remains a leading cause of hospital-acquired infection but weaknesses inherent in currently available typing methods impede effective infection prevention and control. The high resolution offered by whole genome sequencing has the potential to revolutionise our understanding and management of S. aureus infection. To outline the practicalities of whole genome sequencing and discuss how it might shape future infection control practice. We review conventional typing methods and compare these with the potential offered by whole genome sequencing. In contrast with conventional methods, whole genome sequencing discriminates down to single nucleotide differences and allows accurate characterisation of transmission events and outbreaks and additionally provides information about the genetic basis of phenotypic characteristics, including antibiotic susceptibility and virulence. However, translating its potential into routine practice will depend on affordability, acceptable turnaround times and on creating a reliable standardised bioinformatic infrastructure. Whole genome sequencing has the potential to provide a universal test that facilitates outbreak investigation, enables the detection of emerging strains and predicts their clinical importance. Copyright © 2012 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Issues in International Energy Consumption Analysis: Electricity Usage in India’s Housing Sector
2014-01-01
India offers a unique set of features for studying electricity use in the context of a developing country. First, it has a rapidly developing economy with high yearly growth rates in gross domestic product (GDP). Second, it has the second -largest population in the world and is likely to have the largest population in the future. Third, its electric system is maturing—with known difficulties (outages, shortages, issues with reliability and quality) that are characteristic of a developing country. This article focuses on electricity use in the residential sector of India and discusses key trends and provides an overview of available usage estimates from various sources. Indian households are an interesting environment where many of India’s unique features interact. The recent economic gains correlate with rising incomes and possible changes in living standards, which could affect electricity or other energy use within households. Additionally, the maturing electric system and large population in India both offer opportunities to study a range of interactions between electrification and electricity usage in a developing country.
Precision Time Protocol-Based Trilateration for Planetary Navigation
NASA Technical Reports Server (NTRS)
Murdock, Ron
2015-01-01
Progeny Systems Corporation has developed a high-fidelity, field-scalable, non-Global Positioning System (GPS) navigation system that offers precision localization over communications channels. The system is bidirectional, providing position information to both base and mobile units. It is the first-ever wireless use of the Institute of Electrical and Electronics Engineers (IEEE) Precision Time Protocol (PTP) in a bidirectional trilateration navigation system. The innovation provides a precise and reliable navigation capability to support traverse-path planning systems and other mapping applications, and it establishes a core infrastructure for long-term lunar and planetary occupation. Mature technologies are integrated to provide navigation capability and to support data and voice communications on the same network. On Earth, the innovation is particularly well suited for use in unmanned aerial vehicles (UAVs), as it offers a non-GPS precision navigation and location service for use in GPS-denied environments. Its bidirectional capability provides real-time location data to the UAV operator and to the UAV. This approach optimizes assisted GPS techniques and can be used to determine the presence of GPS degradation, spoofing, or jamming.
Cerreia Vioglio, P.; Szell, P. M. J.; Chierotti, M. R.; Gobetto, R.
2018-01-01
Despite the applicability of solid-state NMR to study the halogen bond, the direct NMR detection of 79/81Br covalently bonded to carbon remains impractical due to extremely large spectral widths, even at ultra-high magnetic fields. In contrast, nuclear quadrupole resonance (NQR) offers comparatively sharp resonances. Here, we demonstrate the abilities of 79/81Br NQR to characterize the electronic changes in the C–Br···N halogen bonding motifs found in supramolecular assemblies constructed from 1,4-dibromotetrafluorobenzene and nitrogen-containing heterocycles. An increase in the bromine quadrupolar coupling constant is observed, which correlates linearly with the halogen bond distance (dBr···N). Notably, 79/81Br NQR is able to distinguish between two symmetry-independent halogen bonds in the same crystal structure. This approach offers a rapid and reliable indication for the occurrence of a halogen bond, with experimental times limited only by the observation of 79/81Br NQR resonances. PMID:29899948
Resonant Absorption in GaAs-Based Nanowires by Means of Photo-Acoustic Spectroscopy
NASA Astrophysics Data System (ADS)
Petronijevic, E.; Leahu, G.; Belardini, A.; Centini, M.; Li Voti, R.; Hakkarainen, T.; Koivusalo, E.; Guina, M.; Sibilia, C.
2018-03-01
Semiconductor nanowires made of high refractive index materials can couple the incoming light to specific waveguide modes that offer resonant absorption enhancement under the bandgap wavelength, essential for light harvesting, lasing and detection applications. Moreover, the non-trivial ellipticity of such modes can offer near field interactions with chiral molecules, governed by near chiral field. These modes are therefore very important to detect. Here, we present the photo-acoustic spectroscopy as a low-cost, reliable, sensitive and scattering-free tool to measure the spectral position and absorption efficiency of these modes. The investigated samples are hexagonal nanowires with GaAs core; the fabrication by means of lithography-free molecular beam epitaxy provides controllable and uniform dimensions that allow for the excitation of the fundamental resonant mode around 800 nm. We show that the modulation frequency increase leads to the discrimination of the resonant mode absorption from the overall absorption of the substrate. As the experimental data are in great agreement with numerical simulations, the design can be optimized and followed by photo-acoustic characterization for a specific application.
Uncertainties in obtaining high reliability from stress-strength models
NASA Technical Reports Server (NTRS)
Neal, Donald M.; Matthews, William T.; Vangel, Mark G.
1992-01-01
There has been a recent interest in determining high statistical reliability in risk assessment of aircraft components. The potential consequences are identified of incorrectly assuming a particular statistical distribution for stress or strength data used in obtaining the high reliability values. The computation of the reliability is defined as the probability of the strength being greater than the stress over the range of stress values. This method is often referred to as the stress-strength model. A sensitivity analysis was performed involving a comparison of reliability results in order to evaluate the effects of assuming specific statistical distributions. Both known population distributions, and those that differed slightly from the known, were considered. Results showed substantial differences in reliability estimates even for almost nondetectable differences in the assumed distributions. These differences represent a potential problem in using the stress-strength model for high reliability computations, since in practice it is impossible to ever know the exact (population) distribution. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability. An alternative reliability computation procedure is examined involving determination of a lower bound on the reliability values using extreme value distributions. This procedure reduces the possibility of obtaining nonconservative reliability estimates. Results indicated the method can provide conservative bounds when computing high reliability.
Filho, Alexandre F De Moraes; Gewehr, Pedro M; Maia, Joaquim M; Jakubiak, Douglas R
2018-06-15
This paper presents a gaseous oxygen detection system based on time-resolved phosphorimetry (time-domain), which is used to investigate O2 optical transducers. The primary sensing elements were formed by incorporating iridium(III) and palladium(II) meso -tetrakis(pentafluorophenyl)porphyrin complexes (IrTFPP-CO-Cl and PdTFPP) in polystyrene (PS) solid matrices. Probe excitation was obtained using a violet light-emitting diode (LED) (low power), and the resulting phosphorescence was detected by a high-sensitivity compact photomultiplier tube. The detection system performance and the preparation of the transducers are presented along with their optical properties, phosphorescence lifetimes, calibration curves and photostability. The developed lifetime measuring system showed a good signal-to-noise ratio, and reliable results were obtained from the optodes, even when exposed to moderate levels of O2. The new IrTFPP-CO-Cl membranes exhibited room temperature phosphorescence and moderate sensitivity: <τ0>/<τ21%> ratio of ≈6. A typically high degree of dynamic phosphorescence quenching was observed for the traditional indicator PdTFPP: <τ0>/<τ21%> ratio of ≈36. Pulsed-source time-resolved phosphorimetry combined with a high-sensitivity photodetector can offer potential advantages such as: (i) major dynamic range, (ii) extended temporal resolution (Δτ/Δ[O2]) and (iii) high operational stability. IrTFPP-CO-Cl immobilized in polystyrene is a promising alternative for O2 detection, offering adequate photostability and potentially mid-range sensitivity over Pt(II) and Pd(II) metalloporphyrins.
Mau-Moeller, Anett; Gube, Martin; Felser, Sabine; Feldhege, Frank; Weippert, Matthias; Husmann, Florian; Tischer, Thomas; Bader, Rainer; Bruhn, Sven; Behrens, Martin
2017-08-17
To determine intrasession and intersession reliability of strength measurements and hamstrings to quadriceps strength imbalance ratios (H/Q ratios) using the new isoforce dynamometer. Repeated measures. Exercise science laboratory. Thirty healthy subjects (15 females, 15 males, 27.8 years). Coefficient of variation (CV) and intraclass correlation coefficients (ICC) were calculated for (1) strength parameters, that is peak torque, mean work, and mean power for concentric and eccentric maximal voluntary contractions; isometric maximal voluntary torque (IMVT); rate of torque development (RTD), and (2) H/Q ratios, that is conventional concentric, eccentric, and isometric H/Q ratios (Hcon/Qcon at 60 deg/s, 120 deg/s, and 180 deg/s, Hecc/Qecc at -60 deg/s and Hiso/Qiso) and functional eccentric antagonist to concentric agonist H/Q ratios (Hecc/Qcon and Hcon/Qecc). High reliability: CV <10%, ICC >0.90; moderate reliability: CV between 10% and 20%, ICC between 0.80 and 0.90; low reliability: CV >20%, ICC <0.80. (1) Strength parameters: (a) high intrasession reliability for concentric, eccentric, and isometric measurements, (b) moderate-to-high intersession reliability for concentric and eccentric measurements and IMVT, and (c) moderate-to-high intrasession reliability but low intersession reliability for RTD. (2) H/Q ratios: (a) moderate-to-high intrasession reliability for conventional ratios, (b) high intrasession reliability for functional ratios, (c) higher intersession reliability for Hcon/Qcon and Hiso/Qiso (moderate to high) than Hecc/Qecc (low to moderate), and (d) higher intersession reliability for conventional H/Q ratios (low to high) than functional H/Q ratios (low to moderate). The results have confirmed the reliability of strength parameters and the most frequently used H/Q ratios.
Right Hemisphere Dominance for Emotion Processing in Baboons
ERIC Educational Resources Information Center
Wallez, Catherine; Vauclair, Jacques
2011-01-01
Asymmetries of emotional facial expressions in humans offer reliable indexes to infer brain lateralization and mostly revealed right hemisphere dominance. Studies concerned with oro-facial asymmetries in nonhuman primates largely showed a left-sided asymmetry in chimpanzees, marmosets and macaques. The presence of asymmetrical oro-facial…
A Course in Real-Time Embedded Software
ERIC Educational Resources Information Center
Archibald, J. K.; Fife, W. S.
2007-01-01
Embedded systems are increasingly pervasive, and the creation of reliable controlling software offers unique challenges. Embedded software must interact directly with hardware, it must respond to events in a time-critical fashion, and it typically employs concurrency to meet response time requirements. This paper describes an innovative course…
The Reliability of Randomly Generated Math Curriculum-Based Measurements
ERIC Educational Resources Information Center
Strait, Gerald G.; Smith, Bradley H.; Pender, Carolyn; Malone, Patrick S.; Roberts, Jarod; Hall, John D.
2015-01-01
"Curriculum-Based Measurement" (CBM) is a direct method of academic assessment used to screen and evaluate students' skills and monitor their responses to academic instruction and intervention. Interventioncentral.org offers a math worksheet generator at no cost that creates randomly generated "math curriculum-based measures"…
Baylis, Adriane; Chapman, Kathy; Whitehill, Tara L; Group, The Americleft Speech
2015-11-01
To investigate the validity and reliability of multiple listener judgments of hypernasality and audible nasal emission, in children with repaired cleft palate, using visual analog scaling (VAS) and equal-appearing interval (EAI) scaling. Prospective comparative study of multiple listener ratings of hypernasality and audible nasal emission. Multisite institutional. Five trained and experienced speech-language pathologist listeners from the Americleft Speech Project. Average VAS and EAI ratings of hypernasality and audible nasal emission/turbulence for 12 video-recorded speech samples from the Americleft Speech Project. Intrarater and interrater reliability was computed, as well as linear and polynomial models of best fit. Intrarater and interrater reliability was acceptable for both rating methods; however, reliability was higher for VAS as compared to EAI ratings. When VAS ratings were plotted against EAI ratings, results revealed a stronger curvilinear relationship. The results of this study provide additional evidence that alternate rating methods such as VAS may offer improved validity and reliability over EAI ratings of speech. VAS should be considered a viable method for rating hypernasality and nasal emission in speech in children with repaired cleft palate.
Reliability Considerations for the Operation of Large Accelerator User Facilities
Willeke, F. J.
2016-01-29
The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.
A case study for cloud based high throughput analysis of NGS data using the globus genomics system
Bhuvaneshwar, Krithika; Sulakhe, Dinanath; Gauba, Robinder; ...
2015-01-01
Next generation sequencing (NGS) technologies produce massive amounts of data requiring a powerful computational infrastructure, high quality bioinformatics software, and skilled personnel to operate the tools. We present a case study of a practical solution to this data management and analysis challenge that simplifies terabyte scale data handling and provides advanced tools for NGS data analysis. These capabilities are implemented using the “Globus Genomics” system, which is an enhanced Galaxy workflow system made available as a service that offers users the capability to process and transfer data easily, reliably and quickly to address end-to-end NGS analysis requirements. The Globus Genomicsmore » system is built on Amazon's cloud computing infrastructure. The system takes advantage of elastic scaling of compute resources to run multiple workflows in parallel and it also helps meet the scale-out analysis needs of modern translational genomics research.« less
Concrete volute pumps: technology review and improvement
NASA Astrophysics Data System (ADS)
Prunières, R.; Longatte, F.; Catelan, F. X.; Philippot, J. M.
2012-11-01
When pumps need to deliver large water flow rates (typically more than 5 m3.s-1), concrete volute pumps (CVP) offer an interesting alternative to standard vertical wet-pit pumps. One of the major advantages of CVP is its simplicity in terms of design, manufacturability and maintainability. In addition, CVP geometrical arrangement allows to reach high performances in terms of hydraulic and mechanical behaviour. These advantages can be specifically appreciated when such pumps are used in the energy field for Power Plants which need high flow rate and reliability, and can lead to important financial savings over the Plant lifetime compared to vertical wet-pit pumps. Finally, as CVP was for a long time limited to total head rise lower than 30 mWC, it was established through CFD analysis that the addition of guide vanes between the impeller and the volute allows to achieve higher head rise without risk.
NASA Astrophysics Data System (ADS)
Chu, Hone-Jay; Kong, Shish-Jeng; Chang, Chih-Hua
2018-03-01
The turbidity (TB) of a water body varies with time and space. Water quality is traditionally estimated via linear regression based on satellite images. However, estimating and mapping water quality require a spatio-temporal nonstationary model, while TB mapping necessitates the use of geographically and temporally weighted regression (GTWR) and geographically weighted regression (GWR) models, both of which are more precise than linear regression. Given the temporal nonstationary models for mapping water quality, GTWR offers the best option for estimating regional water quality. Compared with GWR, GTWR provides highly reliable information for water quality mapping, boasts a relatively high goodness of fit, improves the explanation of variance from 44% to 87%, and shows a sufficient space-time explanatory power. The seasonal patterns of TB and the main spatial patterns of TB variability can be identified using the estimated TB maps from GTWR and by conducting an empirical orthogonal function (EOF) analysis.
Need to train your rat? There is an App for that: a touchscreen behavioral evaluation system.
Wolf, Joshua E; Urbano, Catherine M; Ruprecht, Chad M; Leising, Kenneth J
2014-03-01
The increasing demand for highly automated and flexible tasks capable of assessing visual learning and memory in nonhuman animals has led to the exciting development of a wide array of prefabricated touchscreen-equipped systems. However, the high cost of these prefabricated systems has led many researchers to develop or modify their own preexisting equipment. We developed a freely downloadable App, the Touchscreeen Behavioral Evaluation System (TBES) for use in conjunction with an iPad (Apple, Cupertino, California) as an alternative to prefabricated touchscreen systems. TBES allows for stimulus presentation and data collection on an iPad. The touchscreen technology offered by the iPad is attractive to researchers due to its affordability, reliability, and resistance to false inputs. We highlight these, as well as the feasibility and procedural flexibility of TBES, in an effort to promote our system as a competitive alternative to those currently available.
Design of a Low Power, Fast-Spectrum, Liquid-Metal Cooled Surface Reactor System
NASA Astrophysics Data System (ADS)
Marcille, T. F.; Dixon, D. D.; Fischer, G. A.; Doherty, S. P.; Poston, D. I.; Kapernick, R. J.
2006-01-01
In the current 2005 US budget environment, competition for fiscal resources make funding for comprehensive space reactor development programs difficult to justify and accommodate. Simultaneously, the need to develop these systems to provide planetary and deep space-enabling power systems is increasing. Given that environment, designs intended to satisfy reasonable near-term surface missions, using affordable technology-ready materials and processes warrant serious consideration. An initial lunar application design incorporating a stainless structure, 880 K pumped NaK coolant system and a stainless/UO2 fuel system can be designed, fabricated and tested for a fraction of the cost of recent high-profile reactor programs (JIMO, SP-100). Along with the cost reductions associated with the use of qualified materials and processes, this design offers a low-risk, high-reliability implementation associated with mission specific low temperature, low burnup, five year operating lifetime requirements.
A large flat panel multifunction display for military and space applications
NASA Astrophysics Data System (ADS)
Pruitt, James S.
1992-09-01
A flat panel multifunction display (MFD) that offers the size and reliability benefits of liquid crystal display technology while achieving near-CRT display quality is presented. Display generation algorithms that provide exceptional display quality are being implemented in custom VLSI components to minimize MFD size. A high-performance processor converts user-specified display lists to graphics commands used by these components, resulting in high-speed updates of two-dimensional and three-dimensional images. The MFD uses the MIL-STD-1553B data bus for compatibility with virtually all avionics systems. The MFD can generate displays directly from display lists received from the MIL-STD-1553B bus. Complex formats can be stored in the MFD and displayed using parameters from the data bus. The MFD also accepts direct video input and performs special processing on this input to enhance image quality.
In vivo microsampling to capture the elusive exposome
NASA Astrophysics Data System (ADS)
Bessonneau, Vincent; Ings, Jennifer; McMaster, Mark; Smith, Richard; Bragg, Leslie; Servos, Mark; Pawliszyn, Janusz
2017-03-01
Loss and/or degradation of small molecules during sampling, sample transportation and storage can adversely impact biological interpretation of metabolomics data. In this study, we performed in vivo sampling using solid-phase microextraction (SPME) in combination with non-targeted liquid chromatography and high-resolution tandem mass spectrometry (LC-MS/MS) to capture the fish tissue exposome using molecular networking analysis, and the results were contrasted with molecular differences obtained with ex vivo SPME sampling. Based on 494 MS/MS spectra comparisons, we demonstrated that in vivo SPME sampling provided better extraction and stabilization of highly reactive molecules, such as 1-oleoyl-sn-glycero-3-phosphocholine and 1-palmitoleoyl-glycero-3-phosphocholine, from fish tissue samples. This sampling approach, that minimizes sample handling and preparation, offers the opportunity to perform longitudinal monitoring of the exposome in biological systems and improve the reliability of exposure-measurement in exposome-wide association studies.
Solid propulsion advanced concepts
NASA Technical Reports Server (NTRS)
Nakamura, Y.; Shafer, J. I.
1972-01-01
The feasibility and application of a solid propulsion powered spacecraft concept to implement high energy missions independent of multiplanetary swingby opportunities are assessed and recommendations offered for future work. An upper stage, solid propulsion launch vehicle augmentation system was selected as the baseline configuration in view of the established program goals of low cost and high reliability. Spacecraft and propulsion system data that characterize mission performance capabilities were generated to serve as the basis for subsequent tradeoff studies. A cost effectiveness model was used for the preliminary feasibility assessment to provide a meaningful comparative effectiveness measure of the various candidate designs. The results substantiated the feasibility of the powered spacecraft concept when used in conjunction with several intermediate-sized launch vehicles as well as the existence of energy margins by which to exploit the attainment of extended mission capabilities. Additionally, in growth option applications, the employment of advanced propulsion systems and alternate spacecraft approaches appear promising.
Fused electron deficient semiconducting polymers for air stable electron transport.
Onwubiko, Ada; Yue, Wan; Jellett, Cameron; Xiao, Mingfei; Chen, Hung-Yang; Ravva, Mahesh Kumar; Hanifi, David A; Knall, Astrid-Caroline; Purushothaman, Balaji; Nikolka, Mark; Flores, Jean-Charles; Salleo, Alberto; Bredas, Jean-Luc; Sirringhaus, Henning; Hayoz, Pascal; McCulloch, Iain
2018-01-29
Conventional semiconducting polymer synthesis typically involves transition metal-mediated coupling reactions that link aromatic units with single bonds along the backbone. Rotation around these bonds contributes to conformational and energetic disorder and therefore potentially limits charge delocalisation, whereas the use of transition metals presents difficulties for sustainability and application in biological environments. Here we show that a simple aldol condensation reaction can prepare polymers where double bonds lock-in a rigid backbone conformation, thus eliminating free rotation along the conjugated backbone. This polymerisation route requires neither organometallic monomers nor transition metal catalysts and offers a reliable design strategy to facilitate delocalisation of frontier molecular orbitals, elimination of energetic disorder arising from rotational torsion and allowing closer interchain electronic coupling. These characteristics are desirable for high charge carrier mobilities. Our polymers with a high electron affinity display long wavelength NIR absorption with air stable electron transport in solution processed organic thin film transistors.
A case study for cloud based high throughput analysis of NGS data using the globus genomics system
Bhuvaneshwar, Krithika; Sulakhe, Dinanath; Gauba, Robinder; Rodriguez, Alex; Madduri, Ravi; Dave, Utpal; Lacinski, Lukasz; Foster, Ian; Gusev, Yuriy; Madhavan, Subha
2014-01-01
Next generation sequencing (NGS) technologies produce massive amounts of data requiring a powerful computational infrastructure, high quality bioinformatics software, and skilled personnel to operate the tools. We present a case study of a practical solution to this data management and analysis challenge that simplifies terabyte scale data handling and provides advanced tools for NGS data analysis. These capabilities are implemented using the “Globus Genomics” system, which is an enhanced Galaxy workflow system made available as a service that offers users the capability to process and transfer data easily, reliably and quickly to address end-to-endNGS analysis requirements. The Globus Genomics system is built on Amazon 's cloud computing infrastructure. The system takes advantage of elastic scaling of compute resources to run multiple workflows in parallel and it also helps meet the scale-out analysis needs of modern translational genomics research. PMID:26925205
Anderson, Travis; Ren, Fan; Pearton, Stephen; Kang, Byoung Sam; Wang, Hung-Ta; Chang, Chih-Yang; Lin, Jenshan
2009-01-01
In this paper, we review our recent results in developing gas sensors for hydrogen using various device structures, including ZnO nanowires and GaN High Electron Mobility Transistors (HEMTs). ZnO nanowires are particularly interesting because they have a large surface area to volume ratio, which will improve sensitivity, and because they operate at low current levels, will have low power requirements in a sensor module. GaN-based devices offer the advantage of the HEMT structure, high temperature operation, and simple integration with existing fabrication technology and sensing systems. Improvements in sensitivity, recoverability, and reliability are presented. Also reported are demonstrations of detection of other gases, including CO2 and C2H4 using functionalized GaN HEMTs. This is critical for the development of lab-on-a-chip type systems and can provide a significant advance towards a market-ready sensor application. PMID:22408548
Gas dispersion measurements using a mobile Raman lidar system
NASA Technical Reports Server (NTRS)
Houston, J. D.; Brown, D. R.
1986-01-01
The exploitation of natural gas resources to supply energy demands has resulted in the need to engineer pipelines and plants capable of handling extremely high pressures and throughputs. Consequently, more attention has been directed to evaluating the consequences of releases of material whether accidental or deliberate in nature. An important aspect of assessing the consequences of a release is an understanding of how gas disperses in the atmosphere over a wide range of release and atmospheric conditions. The most cost effective way of providing such information is through the development and use of reliable theoretical prediction methods. The need for some form of remote sensing device was identified. The various possibilities studied led to the conclusion that LIDAR (Light Detection And Ranging) offered the most suitable method. The system designed and built is described, and its recent use in monitoring operational ventings from a high pressure transmission system is discussed.
In vivo microsampling to capture the elusive exposome
Bessonneau, Vincent; Ings, Jennifer; McMaster, Mark; Smith, Richard; Bragg, Leslie; Servos, Mark; Pawliszyn, Janusz
2017-01-01
Loss and/or degradation of small molecules during sampling, sample transportation and storage can adversely impact biological interpretation of metabolomics data. In this study, we performed in vivo sampling using solid-phase microextraction (SPME) in combination with non-targeted liquid chromatography and high-resolution tandem mass spectrometry (LC-MS/MS) to capture the fish tissue exposome using molecular networking analysis, and the results were contrasted with molecular differences obtained with ex vivo SPME sampling. Based on 494 MS/MS spectra comparisons, we demonstrated that in vivo SPME sampling provided better extraction and stabilization of highly reactive molecules, such as 1-oleoyl-sn-glycero-3-phosphocholine and 1-palmitoleoyl-glycero-3-phosphocholine, from fish tissue samples. This sampling approach, that minimizes sample handling and preparation, offers the opportunity to perform longitudinal monitoring of the exposome in biological systems and improve the reliability of exposure-measurement in exposome-wide association studies. PMID:28266605
Reliability Issues in Stirling Radioisotope Power Systems
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey; Shah, Ashwin
2005-01-01
Stirling power conversion is a potential candidate for use in a Radioisotope Power System (RPS) for space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power and reduced requirement of radioactive material. Reliability of an RPS that utilizes Stirling power conversion technology is important in order to ascertain long term successful performance. Owing to long life time requirement (14 years), it is difficult to perform long-term tests that encompass all the uncertainties involved in the design variables of components and subsystems comprising the RPS. The requirement for uninterrupted performance reliability and related issues are discussed, and some of the critical areas of concern are identified. An overview of the current on-going efforts to understand component life, design variables at the component and system levels, and related sources and nature of uncertainties are also discussed. Current status of the 110 watt Stirling Radioisotope Generator (SRG110) reliability efforts is described. Additionally, an approach showing the use of past experience on other successfully used power systems to develop a reliability plan for the SRG110 design is outlined.
Kim, Grace Young-Suk; Schatschneider, Christopher; Wanzek, Jeanne; Gatlin, Brandy; Al Otaiba, Stephanie
2017-01-01
We examined how raters and tasks influence measurement error in writing evaluation and how many raters and tasks are needed to reach a desirable level of .90 and .80 reliabilities for children in Grades 3 and 4. A total of 211 children (102 boys) were administered three tasks in narrative and expository genres, respectively, and their written compositions were evaluated in widely used evaluation methods for developing writers: holistic scoring, productivity, and curriculum-based writing scores. Results showed that 54% and 52% of variance in narrative and expository compositions were attributable to true individual differences in writing. Students’ scores varied largely by tasks (30.44% and 28.61% of variance), but not by raters. To reach the reliability of .90, multiple tasks and raters were needed, and for the reliability of .80, a single rater and multiple tasks were needed. These findings offer important implications about reliably evaluating children’s writing skills, given that writing is typically evaluated by a single task and a single rater in classrooms and even in state accountability systems. PMID:29075050
DOE Office of Scientific and Technical Information (OSTI.GOV)
Divan, Deepak; Brumsickle, William; Eto, Joseph
2003-04-01
This report describes a new approach for collecting information on power quality and reliability and making it available in the public domain. Making this information readily available in a form that is meaningful to electricity consumers is necessary for enabling more informed private and public decisions regarding electricity reliability. The system dramatically reduces the cost (and expertise) needed for customers to obtain information on the most significant power quality events, called voltage sags and interruptions. The system also offers widespread access to information on power quality collected from multiple sites and the potential for capturing information on the impacts ofmore » power quality problems, together enabling a wide variety of analysis and benchmarking to improve system reliability. Six case studies demonstrate selected functionality and capabilities of the system, including: Linking measured power quality events to process interruption and downtime; Demonstrating the ability to correlate events recorded by multiple monitors to narrow and confirm the causes of power quality events; and Benchmarking power quality and reliability on a firm and regional basis.« less
Reliability Issues in Stirling Radioisotope Power Systems
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Schreiber, Jeffrey G.
2004-01-01
Stirling power conversion is a potential candidate for use in a Radioisotope Power System (RPS) for space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power and reduced requirement of radioactive material. Reliability of an RPS that utilizes Stirling power conversion technology is important in order to ascertain long term successful performance. Owing to long life time requirement (14 years), it is difficult to perform long-term tests that encompass all the uncertainties involved in the design variables of components and subsystems comprising the RPS. The requirement for uninterrupted performance reliability and related issues are discussed, and some of the critical areas of concern are identified. An overview of the current on-going efforts to understand component life, design variables at the component and system levels, and related sources and nature of uncertainties are also discussed. Current status of the 110 watt Stirling Radioisotope Generator (SRG110) reliability efforts is described. Additionally, an approach showing the use of past experience on other successfully used power systems to develop a reliability plan for the SRG110 design is outlined.
2011-01-01
Background The aim of this study was to develop a child-specific classification system for long bone fractures and to examine its reliability and validity on the basis of a prospective multicentre study. Methods Using the sequentially developed classification system, three samples of between 30 and 185 paediatric limb fractures from a pool of 2308 fractures documented in two multicenter studies were analysed in a blinded fashion by eight orthopaedic surgeons, on a total of 5 occasions. Intra- and interobserver reliability and accuracy were calculated. Results The reliability improved with successive simplification of the classification. The final version resulted in an overall interobserver agreement of κ = 0.71 with no significant difference between experienced and less experienced raters. Conclusions In conclusion, the evaluation of the newly proposed classification system resulted in a reliable and routinely applicable system, for which training in its proper use may further improve the reliability. It can be recommended as a useful tool for clinical practice and offers the option for developing treatment recommendations and outcome predictions in the future. PMID:21548939
Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido
2009-05-01
A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. In vitro characterization with buffered glucose solutions (c(glucose) = 0 - 26 x 10(-3) mol liter(-1)) over 120 h yielded a mean absolute relative error (MARE) of 2.9 +/- 0.9% and a recorded mean flow rate of 330 +/- 48 nl/min with periodic flow rate variation amounting to 24 +/- 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 +/- 59 nl/min and a periodic variation of 22 +/- 6% were recorded. Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 +/- 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. 2009 Diabetes Technology Society.
Ocvirk, Gregor; Hajnsek, Martin; Gillen, Ralph; Guenther, Arnfried; Hochmuth, Gernot; Kamecke, Ulrike; Koelker, Karl-Heinz; Kraemer, Peter; Obermaier, Karin; Reinheimer, Cornelia; Jendrike, Nina; Freckmann, Guido
2009-01-01
Background A novel microdialysis-based continuous glucose monitoring system, the so-called Clinical Research Tool (CRT), is presented. The CRT was designed exclusively for investigational use to offer high analytical accuracy and reliability. The CRT was built to avoid signal artifacts due to catheter clogging, flow obstruction by air bubbles, and flow variation caused by inconstant pumping. For differentiation between physiological events and system artifacts, the sensor current, counter electrode and polarization voltage, battery voltage, sensor temperature, and flow rate are recorded at a rate of 1 Hz. Method In vitro characterization with buffered glucose solutions (cglucose = 0 - 26 × 10-3 mol liter-1) over 120 h yielded a mean absolute relative error (MARE) of 2.9 ± 0.9% and a recorded mean flow rate of 330 ± 48 nl/min with periodic flow rate variation amounting to 24 ± 7%. The first 120 h in vivo testing was conducted with five type 1 diabetes subjects wearing two systems each. A mean flow rate of 350 ± 59 nl/min and a periodic variation of 22 ± 6% were recorded. Results Utilizing 3 blood glucose measurements per day and a physical lag time of 1980 s, retrospective calibration of the 10 in vivo experiments yielded a MARE value of 12.4 ± 5.7. Clarke error grid analysis resulted in 81.0%, 16.6%, 0.8%, 1.6%, and 0% in regions A, B, C, D, and E, respectively. Conclusion The CRT demonstrates exceptional reliability of system operation and very good measurement performance. The ability to differentiate between artifacts and physiological effects suggests the use of the CRT as a reference tool in clinical investigations. PMID:20144284
Shuttle-Derived Launch Vehicles' Capablities: An Overview
NASA Technical Reports Server (NTRS)
Rothschild, William J.; Bailey, Debra A.; Henderson, Edward M.; Crumbly, Chris
2005-01-01
Shuttle-Derived Launch Vehicle (SDLV) concepts have been developed by a collaborative team comprising the Johnson Space Center, Marshall Space Flight Center, Kennedy Space Center, ATK-Thiokol, Lockheed Martin Space Systems Company, The Boeing Company, and United Space Alliance. The purpose of this study was to provide timely information on a full spectrum of low-risk, cost-effective options for STS-Derived Launch Vehicle concepts to support the definition of crew and cargo launch requirements for the Space Exploration Vision. Since the SDLV options use high-reliability hardware, existing facilities, and proven processes, they can provide relatively low-risk capabilities to launch extremely large payloads to low Earth orbit. This capability to reliably lift very large, high-dollar-value payloads could reduce mission operational risks by minimizing the number of complex on-orbit operations compared to architectures based on multiple smaller launchers. The SDLV options also offer several logical spiral development paths for larger exploration payloads. All of these development paths make practical and cost-effective use of existing Space Shuttle Program (SSP) hardware, infrastructure, and launch and flight operations systems. By utilizing these existing assets, the SDLV project could support the safe and orderly transition of the current SSP through the planned end of life in 2010. The SDLV concept definition work during 2004 focused on three main configuration alternatives: a side-mount heavy lifter (approximately 77 MT payload), an in-line medium lifter (approximately 22 MT Crew Exploration Vehicle payload), and an in-line heavy lifter (greater than 100 MT payload). This paper provides an overview of the configuration, performance capabilities, reliability estimates, concept of operations, and development plans for each of the various SDLV alternatives. While development, production, and operations costs have been estimated for each of the SDLV configuration alternatives, these proprietary data have not been included in this paper.
High reliability and implications for nursing leaders.
Riley, William
2009-03-01
To review high reliability theory and discuss its implications for the nursing leader. A high reliability organization (HRO) is considered that which has measurable near perfect performance for quality and safety. The author has reviewed the literature, discussed research findings that contribute to improving reliability in health care organizations, and makes five recommendations for how nursing leaders can create high reliability organizations. Health care is not a safe industry and unintended patient harm occurs at epidemic levels. Health care can learn from high reliability theory and practice developed in other high-risk industries. Viewed by HRO standards, unintended patient injury in health care is excessively high and quality is distressingly low. HRO theory and practice can be successfully applied in health care using advanced interdisciplinary teamwork training and deliberate process design techniques. Nursing has a primary leadership function for ensuring patient safety and achieving high quality in health care organizations. Learning HRO theory and methods for achieving high reliability is a foremost opportunity for nursing leaders.
Weisrock, Fabian; Fritschka, Max; Beckmann, Sebastian; Litmeier, Simon; Wagner, Josephine; Tahirovic, Elvis; Radenovic, Sara; Zelenak, Christine; Hashemi, Djawid; Busjahn, Andreas; Krahn, Thomas; Pieske, Burkert; Dinh, Wilfried; Düngen, Hans-Dirk
2017-08-01
Endothelial dysfunction plays a major role in cardiovascular diseases and pulse amplitude tonometry (PAT) offers a non-invasive way to assess endothelial dysfunction. However, data about the reliability of PAT in cardiovascular patient populations are scarce. Thus, we evaluated the test-retest reliability of PAT using the natural logarithmic transformed reactive hyperaemia index (LnRHI). Our cohort consisted of 91 patients (mean age: 65±9.7 years, 32% female), who were divided into four groups: those with heart failure with preserved ejection fraction (HFpEF) ( n=25), heart failure with reduced ejection fraction (HFrEF) ( n=22), diabetic nephropathy ( n=21), and arterial hypertension ( n=23). All subjects underwent two separate PAT measurements at a median interval of 7 days (range 4-14 days). LnRHI derived by PAT showed good reliability in subjects with diabetic nephropathy (intra-class correlation (ICC) = 0.863) and satisfactory reliability in patients with both HFpEF (ICC = 0.557) and HFrEF (ICC = 0.576). However, in subjects with arterial hypertension, reliability was poor (ICC = 0.125). We demonstrated that PAT is a reliable technique to assess endothelial dysfunction in adults with diabetic nephropathy, HFpEF or HFrEF. However, in subjects with arterial hypertension, we did not find sufficient reliability, which can possibly be attributed to variations in heart rate and the respective time of the assessments. Clinical Trial Registration Identifier: NCT02299960.
Thermal Conduction in Vertically Aligned Copper Nanowire Arrays and Composites.
Barako, Michael T; Roy-Panzer, Shilpi; English, Timothy S; Kodama, Takashi; Asheghi, Mehdi; Kenny, Thomas W; Goodson, Kenneth E
2015-09-02
The ability to efficiently and reliably transfer heat between sources and sinks is often a bottleneck in the thermal management of modern energy conversion technologies ranging from microelectronics to thermoelectric power generation. These interfaces contribute parasitic thermal resistances that reduce device performance and are subjected to thermomechanical stresses that degrade device lifetime. Dense arrays of vertically aligned metal nanowires (NWs) offer the unique combination of thermal conductance from the constituent metal and mechanical compliance from the high aspect ratio geometry to increase interfacial heat transfer and device reliability. In the present work, we synthesize copper NW arrays directly onto substrates via templated electrodeposition and extend this technique through the use of a sacrificial overplating layer to achieve improved uniformity. Furthermore, we infiltrate the array with an organic phase change material and demonstrate the preservation of thermal properties. We use the 3ω method to measure the axial thermal conductivity of freestanding copper NW arrays to be as high as 70 W m(-1) K(-1), which is more than an order of magnitude larger than most commercial interface materials and enhanced-conductivity nanocomposites reported in the literature. These arrays are highly anisotropic, and the lateral thermal conductivity is found to be only 1-2 W m(-1) K(-1). We use these measured properties to elucidate the governing array-scale transport mechanisms, which include the effects of morphology and energy carrier scattering from size effects and grain boundaries.
Quantitative characterization of fatty liver disease using x-ray scattering
NASA Astrophysics Data System (ADS)
Elsharkawy, Wafaa B.; Elshemey, Wael M.
2013-11-01
Nonalcoholic fatty liver disease (NAFLD) is a dynamic condition in which fat abnormally accumulates within the hepatocytes. It is believed to be a marker of risk of later chronic liver diseases, such as liver cirrhosis and carcinoma. The fat content in liver biopsies determines its validity for liver transplantation. Transplantation of livers with severe NAFLD is associated with a high risk of primary non-function. Moreover, NAFLD is recognized as a clinically important feature that influences patient morbidity and mortality after hepatic resection. Unfortunately, there is a lack in a precise, reliable and reproducible method for quantification of NAFLD. This work suggests a method for the quantification of NAFLD. The method is based on the fact that fatty liver tissue would have a characteristic x-ray scattering profile with a relatively intense fat peak at a momentum transfer value of 1.1 nm-1 compared to a soft tissue peak at 1.6 nm-1. The fat content in normal and fatty liver is plotted against three profile characterization parameters (ratio of peak intensities, ratio of area under peaks and ratio of area under fat peak to total profile area) for measured and Monte Carlo simulated x-ray scattering profiles. Results show a high linear dependence (R2>0.9) of the characterization parameters on the liver fat content with a reported high correlation coefficient (>0.9) between measured and simulated data. These results indicate that the current method probably offers reliable quantification of fatty liver disease.
Novel engineered compound semiconductor heterostructures for advanced electronics applications
NASA Astrophysics Data System (ADS)
Stillman, Gregory E.; Holonyak, Nick, Jr.; Coleman, James J.
1992-06-01
To provide the technology base that will enable SDIO capitalization on the performance advantages offered through novel engineered multiple-lavered compound semiconductor structures, this project has focussed on three specific areas: (1) carbon doping of AlGaAs/GaAs and InP/InGaAs materials for reliable high frequency heterojunction bipolar transistors; (2) impurity induced layer disordering and the environmental degradation of AlxGal-xAs-GaAs quantum-well heterostructures and the native oxide stabilization of AlxGal-xAs-GaAs quantum well heterostructure lasers; and (3) non-planar and strained-layer quantum well heterostructure lasers and laser arrays. The accomplishments in this three year research are reported in fifty-six publications and the abstracts included in this report.
Geostationary multipurpose platforms
NASA Technical Reports Server (NTRS)
Bekey, I.; Bowman, R. M.
1981-01-01
In addition to the advantages generally associated with orbital platforms, such as improved reliability, economies of scale, simple connectivity of elements, reduced tracking demands and the restraint of orbital object population growth, geostationary platforms yield: (1) continuous access by fixed ground antennas for communications services; (2) continuous monitoring of phenomena over chosen regions of the earth's surface; (3) a preferred location for many solar-terrestrial physics experiments. The geostationary platform also offers a low-risk and economical solution to the impending saturation of the orbital arc/frequency spectrum, maximizing the capacity of individual slots and increasing the utility of the entire arc. It also allows the use of many small, simple and inexpensive earth stations through complexity inversion and high power per beam. Block diagram and operational flowcharts are provided.
Space Launch System (SLS) Safety, Mission Assurance, and Risk Mitigation
NASA Technical Reports Server (NTRS)
May, Todd
2013-01-01
SLS Driving Objectives: I. Safe: a) Human-rated to provide safe and reliable systems for human missions. b) Protecting the public, NASA workforce, high-value equipment and property, and the environment from potential harm. II. Affordable: a) Maximum use of common elements and existing assets, infrastructure, and workforce. b) Constrained budget environment. c) Competitive opportunities for affordability on-ramps. III. Sustainable: a) Initial capability: 70 metric tons (t), 2017-2021. 1) Serves as primary transportation for Orion and exploration missions. 2) Provides back-up capability for crew/cargo to ISS. b) Evolved capability: 105 t and 130 t, post-2021. 1) Offers large volume for science missions and payloads. 2) Modular and flexible, right-sized for mission requirements.
NASA Technical Reports Server (NTRS)
Bhasin, K. B.; Connolly, D. J.
1986-01-01
Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMIC's to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMIC's is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. In this paper, current developments in GaAs MMIC technology are described, and the status and prospects of the technology are assessed.
Programming languages and compiler design for realistic quantum hardware.
Chong, Frederic T; Franklin, Diana; Martonosi, Margaret
2017-09-13
Quantum computing sits at an important inflection point. For years, high-level algorithms for quantum computers have shown considerable promise, and recent advances in quantum device fabrication offer hope of utility. A gap still exists, however, between the hardware size and reliability requirements of quantum computing algorithms and the physical machines foreseen within the next ten years. To bridge this gap, quantum computers require appropriate software to translate and optimize applications (toolflows) and abstraction layers. Given the stringent resource constraints in quantum computing, information passed between layers of software and implementations will differ markedly from in classical computing. Quantum toolflows must expose more physical details between layers, so the challenge is to find abstractions that expose key details while hiding enough complexity.
Low-Temperature Properties of Silver
Smith, David R.; Fickett, F. R.
1995-01-01
Pure silver is used extensively in the preparation of high-temperature superconductor wires, tapes, films, and other configurations in which the silver not only shields the superconducting material from the surrounding materials, but also provides a degree of flexibility and strain relief, as well as stabilization and low-resistance electrical contact. Silver is relatively expensive, but at this stage of superconductor development, its unique combination of properties seems to offer the only reasonable means of achieving usable lengths of conductor. In this role, the low-temperature physical (electrical, thermal, magnetic, optical) and mechanical properties of the silver all become important. Here we present a collection of properties data extracted from the cryogenic literature and, to the extent possible, selected for reliability. PMID:29151733
A speciation solver for cement paste modeling and the semismooth Newton method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Georget, Fabien, E-mail: fabieng@princeton.edu; Prévost, Jean H., E-mail: prevost@princeton.edu; Vanderbei, Robert J., E-mail: rvdb@princeton.edu
2015-02-15
The mineral assemblage of a cement paste may vary considerably with its environment. In addition, the water content of a cement paste is relatively low and the ionic strength of the interstitial solution is often high. These conditions are extreme conditions with respect to the common assumptions made in speciation problem. Furthermore the common trial and error algorithm to find the phase assemblage does not provide any guarantee of convergence. We propose a speciation solver based on a semismooth Newton method adapted to the thermodynamic modeling of cement paste. The strong theoretical properties associated with these methods offer practical advantages.more » Results of numerical experiments indicate that the algorithm is reliable, robust, and efficient.« less
Programming languages and compiler design for realistic quantum hardware
NASA Astrophysics Data System (ADS)
Chong, Frederic T.; Franklin, Diana; Martonosi, Margaret
2017-09-01
Quantum computing sits at an important inflection point. For years, high-level algorithms for quantum computers have shown considerable promise, and recent advances in quantum device fabrication offer hope of utility. A gap still exists, however, between the hardware size and reliability requirements of quantum computing algorithms and the physical machines foreseen within the next ten years. To bridge this gap, quantum computers require appropriate software to translate and optimize applications (toolflows) and abstraction layers. Given the stringent resource constraints in quantum computing, information passed between layers of software and implementations will differ markedly from in classical computing. Quantum toolflows must expose more physical details between layers, so the challenge is to find abstractions that expose key details while hiding enough complexity.
Advanced cell therapies: targeting, tracking and actuation of cells with magnetic particles.
Connell, John J; Patrick, P Stephen; Yu, Yichao; Lythgoe, Mark F; Kalber, Tammy L
2015-01-01
Regenerative medicine would greatly benefit from a new platform technology that enabled measurable, controllable and targeting of stem cells to a site of disease or injury in the body. Superparamagnetic iron-oxide nanoparticles offer attractive possibilities in biomedicine and can be incorporated into cells, affording a safe and reliable means of tagging. This review describes three current and emerging methods to enhance regenerative medicine using magnetic particles to guide therapeutic cells to a target organ; track the cells using MRI and assess their spatial localization with high precision and influence the behavior of the cell using magnetic actuation. This approach is complementary to the systemic injection of cell therapies, thus expanding the horizon of stem cell therapeutics.
NASA Astrophysics Data System (ADS)
Kathiravan, Deepa; Huang, Bohr-Ran; Saravanan, Adhimoorthy; Yeh, Chien-Jui; Leou, Keh-Chyang; Lin, I.-Nan
2017-12-01
A high-performance ZnO nanotubes (ZNTs)/needle-structured graphitic diamond (NGD) nanohybrid material was prepared and observed the electrochemical sensing properties of liquid acetone in water. Initially, we synthesized NGD film using bias-enhanced growth (BEG) process. Afterwards, a well-etched ZNTs were spatially grown on the NGD film using simple hydrothermal method, and utilized as sensing material for assemble an electrochemical sensor (via EGFET configuration) operating at room temperature. The systematic investigations depict the ultra-high sensing properties attained from ZNTs grown on NGD film. The NGD film mostly have needle or wire shaped diamond grains, which contributes extremely high electrical conductivity. Furthermore, needle shaped diamond grains cover with multi-layer graphitic material generates conduction channels for ZNTs and leads to enhance the oxygen residuals and species. The material stability and conductivity of NGD as well the defects exist with oxygen vacancies in ZNTs offers superior sensing properties. Thus, the interesting combination of these wide band gap semiconductor materials exhibit high sensor response (89 mV/mL), high stability and long-term reliability (tested after 60 days).
SiGe BiCMOS manufacturing platform for mmWave applications
NASA Astrophysics Data System (ADS)
Kar-Roy, Arjun; Howard, David; Preisler, Edward; Racanelli, Marco; Chaudhry, Samir; Blaschke, Volker
2010-10-01
TowerJazz offers high volume manufacturable commercial SiGe BiCMOS technology platforms to address the mmWave market. In this paper, first, the SiGe BiCMOS process technology platforms such as SBC18 and SBC13 are described. These manufacturing platforms integrate 200 GHz fT/fMAX SiGe NPN with deep trench isolation into 0.18μm and 0.13μm node CMOS processes along with high density 5.6fF/μm2 stacked MIM capacitors, high value polysilicon resistors, high-Q metal resistors, lateral PNP transistors, and triple well isolation using deep n-well for mixed-signal integration, and, multiple varactors and compact high-Q inductors for RF needs. Second, design enablement tools that maximize performance and lowers costs and time to market such as scalable PSP and HICUM models, statistical and Xsigma models, reliability modeling tools, process control model tools, inductor toolbox and transmission line models are described. Finally, demonstrations in silicon for mmWave applications in the areas of optical networking, mobile broadband, phased array radar, collision avoidance radar and W-band imaging are listed.
NASA Astrophysics Data System (ADS)
Gabrielli, Alessandro; Loddo, Flavio; Ranieri, Antonio; De Robertis, Giuseppe
2008-10-01
This work is aimed at defining the architecture of a new digital ASIC, namely Slow-Control Adapter (SCA), which will be designed in a commercial 130-nm CMOS technology. This chip will be embedded within a high-speed data acquisition optical link (GBT) to control and monitor the front-end electronics in future high-energy physics experiments. The GBT link provides a transparent transport layer between the SCA and control electronics in the counting room. The proposed SCA supports a variety of common bus protocols to interface with end-user general-purpose electronics. Between the GBT and the SCA a standard 100 Mb/s IEEE-802.3 compatible protocol will be implemented. This standard protocol allows off-line tests of the prototypes using commercial components that support the same standard. The project is justified because embedded applications in modern large HEP experiments require particular care to assure the lowest possible power consumption, still offering the highest reliability demanded by very large particle detectors.
Swanson, Jonathan O; Plotner, David; Franklin, Holly L; Swanson, David L; Lokomba Bolamba, Victor; Lokangaka, Adrien; Sayury Pineda, Irma; Figueroa, Lester; Garces, Ana; Muyodi, David; Esamai, Fabian; Kanaiza, Nancy; Mirza, Waseem; Naqvi, Farnaz; Saleem, Sarah; Mwenechanya, Musaku; Chiwila, Melody; Hamsumonde, Dorothy; McClure, Elizabeth M; Goldenberg, Robert L; Nathan, Robert O
2016-01-01
ABSTRACT High quality is important in medical imaging, yet in many geographic areas, highly skilled sonographers are in short supply. Advances in Internet capacity along with the development of reliable portable ultrasounds have created an opportunity to provide centralized remote quality assurance (QA) for ultrasound exams performed at rural sites worldwide. We sought to harness these advances by developing a web-based tool to facilitate QA activities for newly trained sonographers who were taking part in a cluster randomized trial investigating the role of limited obstetric ultrasound to improve pregnancy outcomes in 5 low- and middle-income countries. We were challenged by connectivity issues, by country-specific needs for website usability, and by the overall need for a high-throughput system. After systematically addressing these needs, the resulting QA website helped drive ultrasound quality improvement across all 5 countries. It now offers the potential for adoption by future ultrasound- or imaging-based global health initiatives. PMID:28031304
Microcolumnar and polycrystalline growth of LaBr3:Ce scintillator
NASA Astrophysics Data System (ADS)
Nagarkar, V. V.; Miller, S.; Sia, R.; Gaysinskiy, V.
2011-05-01
While a wide variety of new scintillators are now available, cerium-doped lanthanide halide scintillators have shown a strong potential toward fulfilling the needs of highly demanding applications such as radioisotope identification at room temperature, homeland security, quantitative molecular imaging for medical diagnostics, and disease staging and research. Despite their extraordinary advantages in terms of light yield and response uniformity over a wide energy range, issues related to reliable, large volume manufacturing of these high-light-yield materials in a rapid and economic manner has not been resolved or purposefully addressed. Here we report on synthesizing LaBr3:Ce scintillator using a thermal evaporation technique, which offers the potential to synthesize large quantities of small-to-large volume, high-quality material in a time-efficient and cost-effective manner. To date we have successfully applied this method to form both microcolumnar films and thick polycrystalline slabs of LaBr3:Ce, and have characterized their light yield, response linearity, decay time and afterglow.
Brief Communication: A low-cost Arduino®-based wire extensometer for earth flow monitoring
NASA Astrophysics Data System (ADS)
Guerriero, Luigi; Guerriero, Giovanni; Grelle, Gerardo; Guadagno, Francesco M.; Revellino, Paola
2017-06-01
Continuous monitoring of earth flow displacement is essential for the understanding of the dynamic of the process, its ongoing evolution and designing mitigation measures. Despite its importance, it is not always applied due to its expense and the need for integration with additional sensors to monitor factors controlling movement. To overcome these problems, we developed and tested a low-cost Arduino-based wire-rail extensometer integrating a data logger, a power system and multiple digital and analog inputs. The system is equipped with a high-precision position transducer that in the test configuration offers a measuring range of 1023 mm and an associated accuracy of ±1 mm, and integrates an operating temperature sensor that should allow potential thermal drift that typically affects this kind of systems to be identified and corrected. A field test, conducted at the Pietrafitta earth flow where additional monitoring systems had been installed, indicates a high reliability of the measurement and a high monitoring stability without visible thermal drift.
Yaman, Yesim Tugce; Abaci, Serdar
2016-01-01
A novel electrochemical sensor gold nanoparticle (AuNP)/polyvinylpyrrolidone (PVP) modified pencil graphite electrode (PGE) was developed for the ultrasensitive determination of Bisphenol A (BPA). The gold nanoparticles were electrodeposited by constant potential electrolysis and PVP was attached by passive adsorption onto the electrode surface. The electrode surfaces were characterized by electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM). The parameters that affected the experimental conditions were researched and optimized. The AuNP/PVP/PGE sensor provided high sensitivity and selectivity for BPA recognition by using square wave adsorptive stripping voltammetry (SWAdSV). Under optimized conditions, the detection limit was found to be 1.0 nM. This new sensor system offered the advantages of simple fabrication which aided the expeditious replication, low cost, fast response, high sensitivity and low background current for BPA. This new sensor system was successfully tested for the detection of the amount of BPA in bottled drinking water with high reliability. PMID:27231912
Motion effects in multistatic millimeter-wave imaging systems
NASA Astrophysics Data System (ADS)
Schiessl, Andreas; Ahmed, Sherif Sayed; Schmidt, Lorenz-Peter
2013-10-01
At airport security checkpoints, authorities are demanding improved personnel screening devices for increased security. Active mm-wave imaging systems deliver the high quality images needed for reliable automatic detection of hidden threats. As mm-wave imaging systems assume static scenarios, motion effects caused by movement of persons during the screening procedure can degrade image quality, so very short measurement time is required. Multistatic imaging array designs and fully electronic scanning in combination with digital beamforming offer short measurement time together with high resolution and high image dynamic range, which are critical parameters for imaging systems used for passenger screening. In this paper, operational principles of such systems are explained, and the performance of the imaging systems with respect to motion within the scenarios is demonstrated using mm-wave images of different test objects and standing as well as moving persons. Electronic microwave imaging systems using multistatic sparse arrays are suitable for next generation screening systems, which will support on the move screening of passengers.
NASA Astrophysics Data System (ADS)
Dalidet, Romain; Peterka, Pavel; Doya, Valérie; Aubrecht, Jan; Koška, Pavel
2018-02-01
Ever extending applications of fiber lasers require energy efficient, high-power, small footprint and reliable fiber lasers and laser wavelength versatility. To meet these demands, next generation of active fibers for high-power fiber lasers is coming out that will eventually offer tailored spectroscopic properties, high robustness and reduced cooling requirements and improved efficiency through tailored pump absorption. We report on numerical modelling of the efficiency of the pump absorption in double clad active fibers with hexagonal shape of the inner cladding cross section and rare-earth-doped core. We analyze both the effect of different radii of the spool on which the fiber is coiled and different fiber twisting rates. Two different launching conditions were investigated: the Gaussian input pump beam and a speckle pattern that mimics the output of the pump laser diode pigtail. We have found that by asymmetric position of the rare-earth-doped core we can significantly improve the pump absorption.
Clinical Biophysics; A New Concept in Undergraduate Medical Education.
ERIC Educational Resources Information Center
Anbar, Michael
1981-01-01
The abilities to understand medical technology, to evaluate new devices and procedures, and to assess their effectiveness, reliability, costs, and risks in comparison with existing methods are discussed. A course in clinical biophysics offered at the State University of New York at Buffalo is described. (Author/MLW)
Transaction-based building controls framework, Volume 2: Platform descriptive model and requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akyol, Bora A.; Haack, Jereme N.; Carpenter, Brandon J.
Transaction-based Building Controls (TBC) offer a control systems platform that provides an agent execution environment that meets the growing requirements for security, resource utilization, and reliability. This report outlines the requirements for a platform to meet these needs and describes an illustrative/exemplary implementation.
Allometric scaling theory applied to FIA biomass estimation
David C. Chojnacky
2002-01-01
Tree biomass estimates in the Forest Inventory and Analysis (FIA) database are derived from numerous methodologies whose abundance and complexity raise questions about consistent results throughout the U.S. A new model based on allometric scaling theory ("WBE") offers simplified methodology and a theoretically sound basis for improving the reliability and...
Evaluation of Complex Human Performance: The Promise of Computer-Based Simulation
ERIC Educational Resources Information Center
Newsom, Robert S.; And Others
1978-01-01
For the training and placement of professional workers, multiple-choice instruments are the norm for wide-scale measurement and evaluation efforts. These instruments contain fundamental problems. Computer-based management simulations may provide solutions to these problems, appear scoreable and reliable, offer increased validity, and are better…
Avoiding pharmacy fraud through automation and audit.
Tripodi, M
1998-12-01
Pharmacy data offer some of the most reliable and evaluative information in managed care today. As fraud constitutes up to 10% of our total health care expenditures, the author explains how monitoring the pharmacy network for fraud and abuse is an easy way of reclaiming some of these losses.
Intergroup Anxiety: A Person X Situation Approach.
ERIC Educational Resources Information Center
Britt, Thomas W.; And Others
1996-01-01
Offers a person X situation approach to the study of intergroup anxiety in which anxiety in intergroup encounters is viewed as a transaction between the individual and the environment. An individual difference measure of intergroup anxiety toward African Americans is developed. Presents studies assessing the scale's reliability and validity.…
Information Superhighway: An Overview of Technology Challenges. Report to the Congress.
ERIC Educational Resources Information Center
General Accounting Office, Washington, DC.
This report focuses on the pivotal technical issues associated with the National Information Infrastructure program, security and privacy, interoperability, and reliability, and presents the General Accounting Office's findings on these challenges. It is reported that while the structures and services to be offered by the information superhighway…
16 CFR 436.9 - Additional prohibitions.
Code of Federal Regulations, 2012 CFR
2012-01-01
... practice in violation of Section 5 of the Federal Trade Commission Act for any franchise seller covered by... a franchise from the franchisor or operated a franchise of the type offered by the franchisor. (2) Can provide an independent and reliable report about the franchise or the experiences of any current...
16 CFR 436.9 - Additional prohibitions.
Code of Federal Regulations, 2014 CFR
2014-01-01
... practice in violation of Section 5 of the Federal Trade Commission Act for any franchise seller covered by... a franchise from the franchisor or operated a franchise of the type offered by the franchisor. (2) Can provide an independent and reliable report about the franchise or the experiences of any current...
16 CFR 436.9 - Additional prohibitions.
Code of Federal Regulations, 2013 CFR
2013-01-01
... practice in violation of Section 5 of the Federal Trade Commission Act for any franchise seller covered by... a franchise from the franchisor or operated a franchise of the type offered by the franchisor. (2) Can provide an independent and reliable report about the franchise or the experiences of any current...
16 CFR 436.9 - Additional prohibitions.
Code of Federal Regulations, 2010 CFR
2010-01-01
... practice in violation of Section 5 of the Federal Trade Commission Act for any franchise seller covered by... a franchise from the franchisor or operated a franchise of the type offered by the franchisor. (2) Can provide an independent and reliable report about the franchise or the experiences of any current...
16 CFR 436.9 - Additional prohibitions.
Code of Federal Regulations, 2011 CFR
2011-01-01
... practice in violation of Section 5 of the Federal Trade Commission Act for any franchise seller covered by... a franchise from the franchisor or operated a franchise of the type offered by the franchisor. (2) Can provide an independent and reliable report about the franchise or the experiences of any current...
ERIC Educational Resources Information Center
Hein, Annamae J.
2011-01-01
The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…
Technology for Online Portfolio Assessment Programs
ERIC Educational Resources Information Center
Ferrara, Victoria M.
2010-01-01
Portfolio assessment is a valid and reliable method to assess experiential learning. Developing a fully online portfolio assessment program is neither easy nor inexpensive. The institution seeking to take its portfolio assessment program online must make a commitment to its students by offering the technologies most suited to meet students' needs.…
Segway Robotic Mobility Platform
2004-10-01
involved changes to firmware and creation of an electrical interface to the RMP. The existing HT design offered the possibility of creating a reliable...mounted on its side and swept back and forth by an Amtec pan-and-tilt unit to acquire 3-D scans of the environment. The RMP also carries an
Research agenda for integrated landscape modeling
Samuel A. Cushman; Donald McKenzie; David L. Peterson; Jeremy Littell; Kevin S. McKelvey
2007-01-01
Reliable predictions of how changing climate and disturbance regimes will affect forest ecosystems are crucial for effective forest management. Current fire and climate research in forest ecosystem and community ecology offers data and methods that can inform such predictions. However, research in these fields occurs at different scales, with disparate goals, methods,...
Research agenda for integrated landscape modeling
Samuel A. Cushman; Donald McKenzie; David L. Peterson; Jeremy Littell; Kevin S. McKelvey
2006-01-01
Reliable predictions of the effects changing climate and disturbance regimes will have on forest ecosystems are crucial for effective forest management. Current fire and climate research in forest ecosystem and community ecology offers data and methods that can inform such predictions. However, research in these fields occurs at different scales, with disparate goals,...
Getting the Most out of the Dictionary
ERIC Educational Resources Information Center
Marckwardt, Albert H.
2012-01-01
The usefulness of the dictionary as a reliable source of information for word meanings, spelling, and pronunciation is widely recognized. But even in these obvious matters, the information that the dictionary has to offer is not always accurately interpreted. With respect to pronunciation there seem to be two general pitfalls: (1) the…
ERIC Educational Resources Information Center
Jones, Corinne A.; Hoffman, Matthew R.; Geng, Zhixian; Abdelhalim, Suzan M.; Jiang, Jack J.; McCulloch, Timothy M.
2014-01-01
Purpose: The purpose of this study was to investigate inter- and intrarater reliability among expert users, novice users, and speech-language pathologists with a semiautomated high-resolution manometry analysis program. We hypothesized that all users would have high intrarater reliability and high interrater reliability. Method: Three expert…
Non-Toxic Reaction Control System for the Reusable First Stage Vehicle
NASA Technical Reports Server (NTRS)
Keith, E. L.; Rothschild, W. J.
1999-01-01
This paper presents the Boeing Reusable Space Systems vision of a Reaction Control System (RCS) for the Reusable First Stage (RFS) being considered as a replacement for the Solid Rocket Booster for the Space Shuttle. The requirement is to achieve reliable vehicle control during the upper atmospheric portion of the RFS trajectory while enabling more efficient ground operations, unhindered by constraints caused by operating with highly toxic RCS propellants. Boeing's objective for this effort is to develop a safer, more efficient and environmentally friendly RCS design approach that is suitable for the RFS concept of operations, including a low cost, efficient turnaround cycle. The Boeing RCS concept utilizes ethanol and liquid oxygen in place of the highly toxic, suspected carcinogen, ozone-depleting mono-methyl-hydrazine and highly toxic nitrogen tetroxide. The Space Shuttle Upgrade program, under the leadership of the NASA Johnson Space Flight Center, is currently developing liquid oxygen and ethanol (ethyl alcohol) technology for use as non-toxic orbital maneuvering system (OMS) and RCS. The development of this liquid oxygen and ethanol technology for the Space Shuttle offers a significant leverage to select much of the same technology for the RFS program. There are significant design and development issues involved with bringing this liquid oxygen and ethanol technology to a state of maturity suitable for an operational RCS. The risks associated with a new LOX and Ethanol RCS are mitigated by maintaining kerosene and hydrogen peroxide RCS technology as an alternative. These issues, presented within this paper, include managing the oxygen supply and achieving reliable ignition in the short pulse mode of engine operation. Performance, reliability and operations requirements are presented along with a specific RCS design concept to satisfying these requirements. The work reported in this paper was performed under NASA Marshall Space Flight Center Contract Number NAS8-97272 to define Reusable First Stage design concepts for the Space Shuttle.
Non-Toxic Reaction Control System for the Reusable First Stage Vehicle
NASA Technical Reports Server (NTRS)
Keith, E. L.; Rothschild, W. J.
1999-01-01
This paper presents the Boeing Reusable Space Systems vision of a Reaction Control System (RCS) for the Reusable First Stage (RFS) being considered as a replacement for the Solid Rocket Booster for the Space Shuttle. The requirement is to,achieve reliable vehicle control during the upper atmospheric portion of the RFS trajectory while enabling more efficient ground operations, unhindered by constraints caused by operating with highly toxic RCS propellants. Boeing's objective for this effort is to develop a safer, more efficient and environmentally friendly RCS design approach that is suitable for the RFS concept of operations, including a low cost, efficient turnaround cycle. The Boeing RCS concept utilizes ethanol and liquid oxygen in place of the highly toxic, suspected carcinogen, ozone- depleting mono-methyl-hydrazine and highly toxic nitrogen tetroxide. The Space Shuttle Upgrade program, under the leadership of the NASA Johnson Space Flight Center, is currently developing liquid oxygen and ethanol (ethyl alcohol) technology for use as non-toxic orbital maneuvering system (OMS) and RCS. The development of this liquid oxygen and ethanol technology for the Space Shuffle offers a significant leverage to select much of the same technology for the RFS program. There are significant design and development issues involved with bringing this liquid oxygen and ethanol technology to a state of maturity suitable for an operational RCS, The risks associated with a new LOX and Ethanol RCS are mitigated by maintaining kerosene and hydrogen peroxide RCS technology as an alternative. These issues, presented within this paper, include managing the oxygen supply and achieving reliable ignition in the short pulse mode of engine operation. Performance, reliability and operations requirements are presented along with a specific RCS design concept to satisfying these requirements. The work reported in this paper was performed under NASA Marshall Space Flight Center Contract to define Reusable First Stage design concepts for the Space Shuttle.
Data mining-based coefficient of influence factors optimization of test paper reliability
NASA Astrophysics Data System (ADS)
Xu, Peiyao; Jiang, Huiping; Wei, Jieyao
2018-05-01
Test is a significant part of the teaching process. It demonstrates the final outcome of school teaching through teachers' teaching level and students' scores. The analysis of test paper is a complex operation that has the characteristics of non-linear relation in the length of the paper, time duration and the degree of difficulty. It is therefore difficult to optimize the coefficient of influence factors under different conditions in order to get text papers with clearly higher reliability with general methods [1]. With data mining techniques like Support Vector Regression (SVR) and Genetic Algorithm (GA), we can model the test paper analysis and optimize the coefficient of impact factors for higher reliability. It's easy to find that the combination of SVR and GA can get an effective advance in reliability from the test results. The optimal coefficient of influence factors optimization has a practicability in actual application, and the whole optimizing operation can offer model basis for test paper analysis.
Fischer, M.; Kelley, A. M.; Ward, E. J.; ...
2017-02-03
Most research on bioenergy short rotation woody crops (SRWC) has been dedicated to the genera Populus and Salix. These species generally require relatively high-input culture, including intensive weed competition control, which increases costs and environmental externalities. Widespread native early successional species, characterized by high productivity and good coppicing ability, may be better adapted to local environmental stresses and therefore could offer alternative low-input bioenergy production systems. In order to test this concept, we established a three-year experiment comparing a widely-used hybrid poplar (Populus nigra × P. maximowiczii, clone ‘NM6’) to two native species, American sycamore (Platanus occidentalis L.) and tuliptreemore » (Liriodendron tulipifera L.) grown under contrasting weed and pest control at a coastal plain site in eastern North Carolina, USA. Mean cumulative aboveground wood production was significantly greater in sycamore, with yields of 46.6 Mg ha -11 under high-inputs and 32.7 Mg ha -1 under low-input culture, which rivaled the high-input NM6 yield of 32.9 Mg ha -1. NM6 under low-input management provided noncompetitive yield of 6.2 Mg ha -1. We also found that sycamore showed superiority in survival, biomass increment, weed resistance, treatment convergence, and within-stand uniformity. All are important characteristics for a bioenergy feedstock crop species, leading to reliable establishment and efficient biomass production. Poor performance in all traits was found for tuliptree, with a maximum yield of 1.2 Mg ha -1, suggesting this native species is a poor choice for SRWC. We then conclude that careful species selection beyond the conventionally used genera may enhance reliability and decrease negative environmental impacts of the bioenergy biomass production sector.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fischer, M.; Kelley, A. M.; Ward, E. J.
Most research on bioenergy short rotation woody crops (SRWC) has been dedicated to the genera Populus and Salix. These species generally require relatively high-input culture, including intensive weed competition control, which increases costs and environmental externalities. Widespread native early successional species, characterized by high productivity and good coppicing ability, may be better adapted to local environmental stresses and therefore could offer alternative low-input bioenergy production systems. In order to test this concept, we established a three-year experiment comparing a widely-used hybrid poplar (Populus nigra × P. maximowiczii, clone ‘NM6’) to two native species, American sycamore (Platanus occidentalis L.) and tuliptreemore » (Liriodendron tulipifera L.) grown under contrasting weed and pest control at a coastal plain site in eastern North Carolina, USA. Mean cumulative aboveground wood production was significantly greater in sycamore, with yields of 46.6 Mg ha -11 under high-inputs and 32.7 Mg ha -1 under low-input culture, which rivaled the high-input NM6 yield of 32.9 Mg ha -1. NM6 under low-input management provided noncompetitive yield of 6.2 Mg ha -1. We also found that sycamore showed superiority in survival, biomass increment, weed resistance, treatment convergence, and within-stand uniformity. All are important characteristics for a bioenergy feedstock crop species, leading to reliable establishment and efficient biomass production. Poor performance in all traits was found for tuliptree, with a maximum yield of 1.2 Mg ha -1, suggesting this native species is a poor choice for SRWC. We then conclude that careful species selection beyond the conventionally used genera may enhance reliability and decrease negative environmental impacts of the bioenergy biomass production sector.« less
Siper, Paige M; Kolevzon, Alexander; Wang, A Ting; Buxbaum, Joseph D; Tavassoli, Teresa
2017-06-01
Sensory reactivity is a new criterion for autism spectrum disorder (ASD) in the Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5). However, there is no consensus on how to reliably measure sensory reactivity, particularly in minimally verbal individuals. The current study is an initial validation of the Sensory Assessment for Neurodevelopmental Disorders (SAND), a novel clinician-administered observation and corresponding caregiver interview that captures sensory symptoms based on DSM-5 criteria for ASD. Eighty children between the ages of 2 and 12 participated in this study; 44 children with ASD and 36 typically developing (TD) children. Sensory reactivity symptoms were measured using the SAND and the already validated Short Sensory Profile (SSP). Initial psychometric properties of the SAND were examined including reliability, validity, sensitivity and specificity. Children with ASD showed significantly more sensory reactivity symptoms compared to TD children across sensory domains (visual, tactile, and auditory) and within sensory subtypes (hyperreactivity, hyporeactivity and seeking). The SAND showed strong internal consistency, inter-rater reliability and test-retest reliability, high sensitivity (95.5%) and specificity (91.7%), and strong convergent validity with the SSP. The SAND provides a novel method to characterize sensory reactivity symptoms based on DSM-5 criteria for ASD. This is the first known sensory assessment that combines a clinician-administered observation and caregiver interview to optimally capture sensory phenotypes characteristic of individuals with neurodevelopmental disorders. The SAND offers a beneficial new tool for both research and clinical purposes and has the potential to meaningfully enhance gold-standard assessment of ASD. Autism Res 2017, 10: 1133-1140. © 2017 International Society for Autism Research, Wiley Periodicals, Inc. © 2017 International Society for Autism Research, Wiley Periodicals, Inc.
Park, Jason; Pillarisetty, Venu G; Brennan, Murray F; Jarnagin, William R; D'Angelica, Michael I; Dematteo, Ronald P; G Coit, Daniel; Janakos, Maria; Allen, Peter J
2010-09-01
Electronic synoptic operative reports (E-SORs) have replaced dictated reports at many institutions, but whether E-SORs adequately document the components and findings of an operation has received limited study. This study assessed the reliability and completeness of E-SORs for pancreatic surgery developed at our institution. An attending surgeon and surgical fellow prospectively and independently completed an E-SOR after each of 112 major pancreatic resections (78 proximal, 29 distal, and 5 central) over a 10-month period (September 2008 to June 2009). Reliability was assessed by calculating the interobserver agreement between attending physician and fellow reports. Completeness was assessed by comparing E-SORs to a case-matched (surgeon and procedure) historical control of dictated reports, using a 39-item checklist developed through an internal and external query of 13 high-volume pancreatic surgeons. Interobserver agreement between attending and fellow was moderate to very good for individual categorical E-SOR items (kappa = 0.65 to 1.00, p < 0.001 for all items). Compared with dictated reports, E-SORs had significantly higher completeness checklist scores (mean 88.8 +/- 5.4 vs 59.6 +/- 9.2 [maximum possible score, 100], p < 0.01) and were available in patients' electronic records in a significantly shorter interval of time (median 0.5 vs 5.8 days from case end, p < 0.01). The mean time taken to complete E-SORs was 4.0 +/- 1.6 minutes per case. E-SORs for pancreatic surgery are reliable, complete in data collected, and rapidly available, all of which support their clinical implementation. The inherent strengths of E-SORs offer real promise of a new standard for operative reporting and health communication. Copyright 2010 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Validity and reliability of the Hawaii anaerobic run test.
Kimura, Iris F; Stickley, Christopher D; Lentz, Melissa A; Wages, Jennifer J; Yanagi, Kazuhiko; Hetzler, Ronald K
2014-05-01
This study examined the reliability and validity of the Hawaii anaerobic run test (HART) by comparing anaerobic capacity measures obtained to those during the Wingate Anaerobic Test (WAnT). Ninety-six healthy physically active volunteers (age, 22.0 ± 2.8 years; height, 163.9 ± 9.5 cm; body mass, 70.6 ± 14.7 kg; body fat %, 19.29 ± 5.39%) participated in this study. Each participant performed 2 anaerobic capacity tests: the WAnT and the HART by random assignment on separate days. The reliability of the HART was calculated from 2 separate trials of the test and then determined through intraclass correlation coefficients (ICCs). Blood samples were collected, and lactate was analyzed both pretest and posttest for each of the 2 exercise modes. Heart rate and rate of perceived exertion were also measured pre- and post-exercise. Hawaii anaerobic run test peak and mean momentum were calculated as body mass times highest or average split velocity, respectively. Intraclass correlation coefficients between trials of the HART for peak and mean momentum were 0.98 and 0.99, respectively (SEM = 18.8 and 25.7, respectively). Validity of the HART was established through comparison of momentum on the HART with power on the WAnT. High correlations were found between peak power and peak momentum (r = 0.88), as well as mean power and mean momentum (r = 0.94). The HART was considered to be a reliable test of anaerobic power. The HART was also determined to be a valid test of anaerobic power when compared with the WAnT. When testing healthy college-aged individuals, the HART offers an easy and inexpensive alternative maximal effort anaerobic power test to other established tests.
Grant, Andrew J; Vermunt, Jan D; Kinnersley, Paul; Houston, Helen
2007-01-01
Background Portfolio learning enables students to collect evidence of their learning. Component tasks making up a portfolio can be devised that relate directly to intended learning outcomes. Reflective tasks can stimulate students to recognise their own learning needs. Assessment of portfolios using a rating scale relating to intended learning outcomes offers high content validity. This study evaluated a reflective portfolio used during a final-year attachment in general practice (family medicine). Students were asked to evaluate the portfolio (which used significant event analysis as a basis for reflection) as a learning tool. The validity and reliability of the portfolio as an assessment tool were also measured. Methods 81 final-year medical students completed reflective significant event analyses as part of a portfolio created during a three-week attachment (clerkship) in general practice (family medicine). As well as two reflective significant event analyses each portfolio contained an audit and a health needs assessment. Portfolios were marked three times; by the student's GP teacher, the course organiser and by another teacher in the university department of general practice. Inter-rater reliability between pairs of markers was calculated. A questionnaire enabled the students' experience of portfolio learning to be determined. Results Benefits to learning from reflective learning were limited. Students said that they thought more about the patients they wrote up in significant event analyses but information as to the nature and effect of this was not forthcoming. Moderate inter-rater reliability (Spearman's Rho .65) was found between pairs of departmental raters dealing with larger numbers (20 – 60) of portfolios. Inter-rater reliability of marking involving GP tutors who only marked 1 – 3 portfolios was very low. Students rated highly their mentoring relationship with their GP teacher but found the portfolio tasks time-consuming. Conclusion The inter-rater reliability observed in this study should be viewed alongside the high validity afforded by the authenticity of the learning tasks (compared with a sample of a student's learning taken by an exam question). Validity is enhanced by the rating scale which directly connects the grade given with intended learning outcomes. The moderate inter-rater reliability may be increased if a portfolio is completed over a longer period of time and contains more component pieces of work. The questionnaire used in this study only accessed limited information about the effect of reflection on students' learning. Qualitative methods of evaluation would determine the students experience in greater depth. It would be useful to evaluate the effects of reflective learning after students have had more time to get used to this unfamiliar method of learning and to overcome any problems in understanding the task. PMID:17397544
Grant, Andrew J; Vermunt, Jan D; Kinnersley, Paul; Houston, Helen
2007-03-30
Portfolio learning enables students to collect evidence of their learning. Component tasks making up a portfolio can be devised that relate directly to intended learning outcomes. Reflective tasks can stimulate students to recognise their own learning needs. Assessment of portfolios using a rating scale relating to intended learning outcomes offers high content validity. This study evaluated a reflective portfolio used during a final-year attachment in general practice (family medicine). Students were asked to evaluate the portfolio (which used significant event analysis as a basis for reflection) as a learning tool. The validity and reliability of the portfolio as an assessment tool were also measured. 81 final-year medical students completed reflective significant event analyses as part of a portfolio created during a three-week attachment (clerkship) in general practice (family medicine). As well as two reflective significant event analyses each portfolio contained an audit and a health needs assessment. Portfolios were marked three times; by the student's GP teacher, the course organiser and by another teacher in the university department of general practice. Inter-rater reliability between pairs of markers was calculated. A questionnaire enabled the students' experience of portfolio learning to be determined. Benefits to learning from reflective learning were limited. Students said that they thought more about the patients they wrote up in significant event analyses but information as to the nature and effect of this was not forthcoming. Moderate inter-rater reliability (Spearman's Rho .65) was found between pairs of departmental raters dealing with larger numbers (20-60) of portfolios. Inter-rater reliability of marking involving GP tutors who only marked 1-3 portfolios was very low. Students rated highly their mentoring relationship with their GP teacher but found the portfolio tasks time-consuming. The inter-rater reliability observed in this study should be viewed alongside the high validity afforded by the authenticity of the learning tasks (compared with a sample of a student's learning taken by an exam question). Validity is enhanced by the rating scale which directly connects the grade given with intended learning outcomes. The moderate inter-rater reliability may be increased if a portfolio is completed over a longer period of time and contains more component pieces of work. The questionnaire used in this study only accessed limited information about the effect of reflection on students' learning. Qualitative methods of evaluation would determine the students experience in greater depth. It would be useful to evaluate the effects of reflective learning after students have had more time to get used to this unfamiliar method of learning and to overcome any problems in understanding the task.
Rabelo, Michelle; Nunes, Guilherme S; da Costa Amante, Natália Menezes; de Noronha, Marcos; Fachin-Martins, Emerson
2016-02-01
Muscle weakness is the main cause of motor impairment among stroke survivors and is associated with reduced peak muscle torque. To systematically investigate and organize the evidence of the reliability of muscle strength evaluation measures in post-stroke survivors with chronic hemiparesis. Two assessors independently searched four electronic databases in January 2014 (Medline, Scielo, CINAHL, Embase). Inclusion criteria comprised studies on reliability on muscle strength assessment in adult post-stroke patients with chronic hemiparesis. We extracted outcomes from included studies about reliability data, measured by intraclass correlation coefficient (ICC) and/or similar. The meta-analyses were conducted only with isokinetic data. Of 450 articles, eight articles were included for this review. After quality analysis, two studies were considered of high quality. Five different joints were analyzed within the included studies (knee, hip, ankle, shoulder, and elbow). Their reliability results varying from low to very high reliability (ICCs from 0.48 to 0.99). Results of meta-analysis for knee extension varying from high to very high reliability (pooled ICCs from 0.89 to 0.97), for knee flexion varying from high to very high reliability (pooled ICCs from 0.84 to 0.91) and for ankle plantar flexion showed high reliability (pooled ICC = 0.85). Objective muscle strength assessment can be reliably used in lower and upper extremities in post-stroke patients with chronic hemiparesis.
Low Earth Orbit Raider (LER) winged air launch vehicle concept
NASA Technical Reports Server (NTRS)
Feaux, Karl; Jordan, William; Killough, Graham; Miller, Robert; Plunk, Vonn
1989-01-01
The need to launch small payloads into low earth orbit has increased dramatically during the past several years. The Low Earth orbit Raider (LER) is an answer to this need. The LER is an air-launched, winged vehicle designed to carry a 1500 pound payload into a 250 nautical mile orbit. The LER is launched from the back of a 747-100B at 35,000 feet and a Mach number of 0.8. Three staged solid propellant motors offer safe ground and flight handling, reliable operation, and decreased fabrication cost. The wing provides lift for 747 separation and during the first stage burn. Also, aerodynamic controls are provided to simplify first stage maneuvers. The air-launch concept offers many advantages to the consumer compared to conventional methods. Launching at 35,000 feet lowers atmospheric drag and other loads on the vehicle considerably. Since the 747 is a mobile launch pad, flexibility in orbit selection and launch time is unparalleled. Even polar orbits are accessible with a decreased payload. Most importantly, the LER launch service can come to the customer, satellites and experiments need not be transported to ground based launch facilities. The LER is designed to offer increased consumer freedom at a lower cost over existing launch systems. Simplistic design emphasizing reliability at low cost allows for the light payloads of the LER.
Griffiths, A; Cox, T; Karanika, M; Khan, S; Tomás, J M
2006-10-01
To examine the factor structure, reliability, and validity of a new context-specific questionnaire for the assessment of work and organisational factors. The Work Organisation Assessment Questionnaire (WOAQ) was developed as part of a risk assessment and risk reduction methodology for hazards inherent in the design and management of work in the manufacturing sector. Two studies were conducted. Data were collected from 524 white- and blue-collar employees from a range of manufacturing companies. Exploratory factor analysis was carried out on 28 items that described the most commonly reported failures of work design and management in companies in the manufacturing sector. Concurrent validity data were also collected. A reliability study was conducted with a further 156 employees. Principal component analysis, with varimax rotation, revealed a strong 28-item, five factor structure. The factors were named: quality of relationships with management, reward and recognition, workload, quality of relationships with colleagues, and quality of physical environment. Analyses also revealed a more general summative factor. Results indicated that the questionnaire has good internal consistency and test-retest reliability and validity. Being associated with poor employee health and changes in health related behaviour, the WOAQ factors are possible hazards. It is argued that the strength of those associations offers some estimation of risk. Feedback from the organisations involved indicated that the WOAQ was easy to use and meaningful for them as part of their risk assessment procedures. The studies reported here describe a model of the hazards to employee health and health related behaviour inherent in the design and management of work in the manufacturing sector. It offers an instrument for their assessment. The scales derived which form the WOAQ were shown to be reliable, valid, and meaningful to the user population.
NASA Astrophysics Data System (ADS)
Taylor, John R.; Stolz, Christopher J.
1993-08-01
Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.
NASA Astrophysics Data System (ADS)
Taylor, J. R.; Stolz, C. J.
1992-12-01
Laser system performance and reliability depends on the related performance and reliability of the optical components which define the cavity and transport subsystems. High-average-power and long transport lengths impose specific requirements on component performance. The complexity of the manufacturing process for optical components requires a high degree of process control and verification. Qualification has proven effective in ensuring confidence in the procurement process for these optical components. Issues related to component reliability have been studied and provide useful information to better understand the long term performance and reliability of the laser system.
JOHNSON NOISE THERMOMETRY FOR DRIFT-FREE MEASUREMENTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Britton Jr, Charles L; Ezell, N Dianne Bull; Roberts, Michael
In order for Johnson Noise Thermometry (JNT) to be beneficial to SMR designers, it must offer advantages beyond the current state-of-the-art technology. Comparisons to traditional RTDs and thermocouples will involve life-cycle costs, installation footprint, reliability, and accuracy. With JNT, there is additional equipment beyond what is required for the traditional RTD measurement. Therefore, the JNT-RTD system will involve additional complexity and this additional complexity must be justified. Operators will want to know that the measurement is reliable and trustworthy. It is also important that the sensor involve little, if any, additional ongoing maintenance work and that it has a lowmore » probability of causing any malfunction of the primary measurement channel. If these features can be successfully demonstrated, the JNT-RTD system could potentially save money and increase plant reliability.« less
NASA Astrophysics Data System (ADS)
Venet, N.; Sotom, M.; Gachon, H.; Foucal, V.; Pez, M.; Heikkinen, V.; Tuominen, T.; Pantoja, S.
2017-11-01
The satellite telecommunication sector is continuously facing new challenges. Operators turn towards increasing capacity payloads with higher number of beams and broader bandwidth, in order to cope with exhausting orbital positions and to lower the cost of in-orbit delivery of bit. Only satellites able to provide high data rate connections to numerous users are expected to achieve affordable communication prices. On the other hand, as the telecom market grows and the range of offered services (HDTV, Video On Demand, Triple Play), operators call for more versatile solutions to quickly grasp new markets and to adapt to these evolutions over the average 15 years of a satellite lifetime. Flexible payloads have found an increasing interest for a number of years. Flexibility is considered as a means for a better commercial exploitation of a satellite fleet and a better allocation of resource in response to traffic evolution and/or changing business plans, with potential advantages such as a wider range of applications, less customization for specific missions, increased production runs of equipment, enhancement of reliability, reduction of equipment cost, reduction of program schedules [1]. Flexibility is expected to be offered in spectrum management and frequency plan, in coverage, or in the repeater power allocation. The industry is taking up the challenge both by improving current telecom satellites and offering new payload technology, more flexible and able to address the new markets. From a system integrator perspective, flexibility is as an opportunity to design more generic payloads, that can be customized during or after fabrication only, thus shortening the design-to-manufacturing cycle, and improving the industry competitiveness.
Witkowska, Evelin; Jagielski, Tomasz; Kamińska, Agnieszka
2018-03-05
This paper demonstrates that surface-enhanced Raman spectroscopy (SERS) coupled with principal component analysis (PCA) can serve as a fast and reliable technique for detection and identification of dermatophyte fungi at both genus and species level. Dermatophyte infections are the most common mycotic diseases worldwide, affecting a quarter of the human population. Currently, there is no optimal method for detection and identification of fungal diseases, as each has certain limitations. Here, for the first time, we have achieved with a high accuracy, differentiation of dermatophytes representing three major genera, i.e. Trichophyton, Microsporum, and Epidermophyton. Two first principal components (PC), namely PC-1 and PC-2, gave together 97% of total variance. Additionally, species-level identification within the Trichophyton genus has been performed. PC-1 and PC-2, which are the most diagnostically significant, explain 98% of the variance in the data obtained from spectra of: Trichophyton rubrum, Trichophyton menatgrophytes, Trichophyton interdigitale and Trichophyton tonsurans. This study offers a new diagnostic approach for the identification of dermatophytes. Being fast, reliable and cost-effective, it has the potential to be incorporated in the clinical practice to improve diagnostics of medically important fungi. Copyright © 2017 Elsevier B.V. All rights reserved.
Genus- and species-level identification of dermatophyte fungi by surface-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Witkowska, Evelin; Jagielski, Tomasz; Kamińska, Agnieszka
2018-03-01
This paper demonstrates that surface-enhanced Raman spectroscopy (SERS) coupled with principal component analysis (PCA) can serve as a fast and reliable technique for detection and identification of dermatophyte fungi at both genus and species level. Dermatophyte infections are the most common mycotic diseases worldwide, affecting a quarter of the human population. Currently, there is no optimal method for detection and identification of fungal diseases, as each has certain limitations. Here, for the first time, we have achieved with a high accuracy, differentiation of dermatophytes representing three major genera, i.e. Trichophyton, Microsporum, and Epidermophyton. Two first principal components (PC), namely PC-1 and PC-2, gave together 97% of total variance. Additionally, species-level identification within the Trichophyton genus has been performed. PC-1 and PC-2, which are the most diagnostically significant, explain 98% of the variance in the data obtained from spectra of: Trichophyton rubrum, Trichophyton menatgrophytes, Trichophyton interdigitale and Trichophyton tonsurans. This study offers a new diagnostic approach for the identification of dermatophytes. Being fast, reliable and cost-effective, it has the potential to be incorporated in the clinical practice to improve diagnostics of medically important fungi.
NASA Astrophysics Data System (ADS)
Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; Isaacman, G.; Goldstein, A. H.; Hering, S. V.
2014-12-01
A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week-1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.
Kreisberg, N. M.; Worton, D. R.; Zhao, Y.; ...
2014-12-12
A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introductionmore » using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.« less
I want to help you, but I am not sure why: gaze-cuing induces altruistic giving.
Rogers, Robert D; Bayliss, Andrew P; Szepietowska, Anna; Dale, Laura; Reeder, Lydia; Pizzamiglio, Gloria; Czarna, Karolina; Wakeley, Judi; Cowen, Phillip J; Tipper, Steven P
2014-04-01
Detecting subtle indicators of trustworthiness is highly adaptive for moving effectively amongst social partners. One powerful signal is gaze direction, which individuals can use to inform (or deceive) by looking toward (or away from) important objects or events in the environment. Here, across 5 experiments, we investigate whether implicit learning about gaze cues can influence subsequent economic transactions; we also examine some of the underlying mechanisms. In the 1st experiment, we demonstrate that people invest more money with individuals whose gaze information has previously been helpful, possibly reflecting enhanced trust appraisals. However, in 2 further experiments, we show that other mechanisms driving this behavior include obligations to fairness or (painful) altruism, since people also make more generous offers and allocations of money to individuals with reliable gaze cues in adapted 1-shot ultimatum games and 1-shot dictator games. In 2 final experiments, we show that the introduction of perceptual noise while following gaze can disrupt these effects, but only when the social partners are unfamiliar. Nonconscious detection of reliable gaze cues can prompt altruism toward others, probably reflecting the interplay of systems that encode identity and control gaze-evoked attention, integrating the reinforcement value of gaze cues.
HPTLC-FLD-SERS as a facile and reliable screening tool: Exemplarily shown with tyramine in cheese.
Wang, Liao; Xu, Xue-Ming; Chen, Yi-Sheng; Ren, Jie; Liu, Yun-Tao
2018-04-01
The serious cytotoxicity of tyramine attracted marked attention as it induced necrosis of human intestinal cells. This paper presented a novel and facile high performance thin-layer chromatography (HPTLC) method tailored for screening tyramine in cheese. Separation was performed on glass backed silica gel plates, using methanol/ethyl acetate/ammonia (6/4/1 v/v/v) as the mobile phase. Special efforts were focused on optimizing conditions (substrate preparation, laser wavelength, salt types and concentrations) of surface enhanced Raman spectroscopy (SERS) measurements directly on plates after derivatization, which enabled molecule-specific identification of targeted bands. In parallel, fluorescent densitometry (FLD) scanning at 380400 nm offered satisfactory quantitative performances (LOD 9 ng/zone, LOQ 17 ng/zone, linearity 0.9996 and %RSD 6.7). Including a quick extraction/cleanup step, the established method was successfully validated with different cheese samples, both qualitatively (straightforward confirmation) and quantitatively (recovery rates from 83.7 to 108.5%). Beyond this application, HPTLC-FLD-SERS provided a new horizon in fast and reliable screening of sophisticated samples like food and herb drugs, striking an excellent balance between specificity, sensitivity and simplicity. Copyright © 2017. Published by Elsevier B.V.
FireProt: Energy- and Evolution-Based Computational Design of Thermostable Multiple-Point Mutants.
Bednar, David; Beerens, Koen; Sebestova, Eva; Bendl, Jaroslav; Khare, Sagar; Chaloupkova, Radka; Prokop, Zbynek; Brezovsky, Jan; Baker, David; Damborsky, Jiri
2015-11-01
There is great interest in increasing proteins' stability to enhance their utility as biocatalysts, therapeutics, diagnostics and nanomaterials. Directed evolution is a powerful, but experimentally strenuous approach. Computational methods offer attractive alternatives. However, due to the limited reliability of predictions and potentially antagonistic effects of substitutions, only single-point mutations are usually predicted in silico, experimentally verified and then recombined in multiple-point mutants. Thus, substantial screening is still required. Here we present FireProt, a robust computational strategy for predicting highly stable multiple-point mutants that combines energy- and evolution-based approaches with smart filtering to identify additive stabilizing mutations. FireProt's reliability and applicability was demonstrated by validating its predictions against 656 mutations from the ProTherm database. We demonstrate that thermostability of the model enzymes haloalkane dehalogenase DhaA and γ-hexachlorocyclohexane dehydrochlorinase LinA can be substantially increased (ΔTm = 24°C and 21°C) by constructing and characterizing only a handful of multiple-point mutants. FireProt can be applied to any protein for which a tertiary structure and homologous sequences are available, and will facilitate the rapid development of robust proteins for biomedical and biotechnological applications.
Piezoelectric control of needle-free transdermal drug delivery.
Stachowiak, Jeanne C; von Muhlen, Marcio G; Li, Thomas H; Jalilian, Laleh; Parekh, Sapun H; Fletcher, Daniel A
2007-12-04
Transdermal drug delivery occurs primarily through hypodermic needle injections, which cause pain, require a trained administrator, and may contribute to the spread of disease. With the growing number of pharmaceutical therapies requiring transdermal delivery, an effective, safe, and simple needle-free alternative is needed. We present and characterize a needle-free jet injector that employs a piezoelectric actuator to accelerate a micron-scale stream of fluid (40-130 microm diameter) to velocities sufficient for skin penetration and drug delivery (50-160 m/s). Existing jet injectors, powered by compressed springs and gases, are not widely used due to painful injections and poor reliability in skin penetration depth and dose. In contrast, our device offers electronic control of the actuator expansion rate, resulting in direct control of jet velocity and thus the potential for more precise injections. We apply a simple fluid-dynamic model to predict the device response to actuator expansion. Further, we demonstrate that injection parameters including expelled volume, jet pressure, and penetration depth in soft materials vary with actuator expansion rate, but are highly coupled. Finally, we discuss how electronically-controlled jet injectors may enable the decoupling of injection parameters such as penetration depth and dose, improving the reliability of needle-free transdermal drug delivery.
Architectural and engineering issues for building an optical Internet
NASA Astrophysics Data System (ADS)
St. Arnaud, Bill
1998-10-01
Recent developments in high density Wave Division Multiplexing fiber systems allows for the deployment of a dedicated optical Internet network for large volume backbone pipes that does not require an underlying multi-service SONET/SDH and ATM transport protocol. Some intrinsic characteristics of Internet traffic such as its self similar nature, server bound congestion, routing and data asymmetry allow for highly optimized traffic engineered networks using individual wavelengths. By transmitting GigaBit Ethernet or SONET/SDH frames natively over WDM wavelengths that directly interconnect high performance routers the original concept of the Internet as an intrinsically survivable datagram network is possible. Traffic engineering, restoral, protection and bandwidth management of the network must now be carried out at the IP layer and so new routing or switching protocols such as MPLS that allow for uni- directional paths with fast restoral and protection at the IP layer become essential for a reliable production network. The deployment of high density WDM municipal and campus networks also gives carriers and ISPs the flexibility to offer customers as integrated and seamless set of optical Internet services.
High power disk lasers: advances and applications
NASA Astrophysics Data System (ADS)
Havrilla, David; Holzer, Marco
2011-02-01
Though the genesis of the disk laser concept dates to the early 90's, the disk laser continues to demonstrate the flexibility and the certain future of a breakthrough technology. On-going increases in power per disk, and improvements in beam quality and efficiency continue to validate the genius of the disk laser concept. As of today, the disk principle has not reached any fundamental limits regarding output power per disk or beam quality, and offers numerous advantages over other high power resonator concepts, especially over monolithic architectures. With well over 1000 high power disk lasers installations, the disk laser has proven to be a robust and reliable industrial tool. With advancements in running cost, investment cost and footprint, manufacturers continue to implement disk laser technology with more vigor than ever. This paper will explain important details of the TruDisk laser series and process relevant features of the system, like pump diode arrangement, resonator design and integrated beam guidance. In addition, advances in applications in the thick sheet area and very cost efficient high productivity applications like remote welding, remote cutting and cutting of thin sheets will be discussed.
Poly-silicon TFT AM-OLED on thin flexible metal substrates
NASA Astrophysics Data System (ADS)
Afentakis, Themis; Hatalis, Miltiadis K.; Voutsas, Apostolos T.; Hartzell, John W.
2003-05-01
Thin metal foils present an excellent alternative to polymers for the fabrication of large area, flexible displays. Their main advantage spurs from their ability to withstand higher temperatures during processing; microelectronic fabrication at elevated temperatures offers the ability to utilize a variety of crystallization processes for the active layer of devices and thermally grown gate dielectrics. This can lead to high performance (high mobility, low threshold voltage) low cost and highly reliable thin film transistors. In some cases, the conductive substrate can also be used to provide power to the active devices, thus reducing layout complexity. This paper discusses the first successful attempt to design and fabricate a variety of active matrix organic light emitting diode displays on thin, flexible stainless steel foils. Different pixel architectures, such as two- and four-transistor implementations, and addressing modes, such as voltage- or current-driven schemese are examined. This work clearly demonstrates the advantages associated with the fabrication of OLED displays on thin metal foils, which - through roll-to-roll processing - can potentially result in revolutionizing today's display processing, leading to a new generation of low cost, high performance versatile display systems.
Mahn, Andrea; Ismail, Maritza
2011-11-15
Ammonium sulfate precipitation (ASP) was explored as a method for depleting some highly abundant proteins from blood plasma, in order to reduce the dynamic range of protein concentration and to improve the detection of low abundance proteins by 2D-PAGE. 40% ammonium sulfate saturation was chosen since it allowed depleting 39% albumin and 82% α-1-antitrypsin. ASP-depletion showed high reproducibility in 2D-PAGE analysis (4.2% variation in relative abundance of albumin), similar to that offered by commercial affinity-depletion columns. Besides, it allowed detecting 59 spots per gel, very close to the number of spots detected in immuno-affinity-depleted plasma. Thus, ASP at 40% saturation is a reliable depletion method that may help in proteomic analysis of blood plasma. Finally, ASP-depletion seems to be complementary to hydrophobic interaction chromatography (HIC)-depletion, and therefore an ASP-step followed by a HIC-step could probably deplete the most highly abundant plasma proteins, thus improving the detection of low abundance proteins by 2D-PAGE. Copyright © 2011 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Everson, Mark D.; Sandoval, Jose Miguel; Berson, Nancy; Crowson, Mary; Robinson, Harriet
2012-01-01
In the absence of photographic or DNA evidence, a credible eyewitness, or perpetrator confession, forensic evaluators in cases of alleged child sexual abuse must rely on psychosocial or "soft" evidence, often requiring substantial professional judgment for case determination. This article offers a three-part rebuttal to Herman's (2009) argument…
Emotioncy: A Potential Measure of Readability
ERIC Educational Resources Information Center
Pishghadamn, Reza; Abbasnejad, Hannaheh
2016-01-01
Given the deficiencies of readability formulae as reliable tools for measuring text readability in educational settings, this study aims to offer a new measure to improve the current methods of testing the readability levels of texts through the incorporation of the newly-developed concept of emotioncy. To this end, a group of 221 students were…
Observer Use of Standardized Observation Protocols in Consequential Observation Systems
ERIC Educational Resources Information Center
Bell, Courtney A.; Yi, Qi; Jones, Nathan D.; Lewis, Jennifer M.; McLeod, Monica; Liu, Shuangshuang
2014-01-01
Evidence from a handful of large-scale studies suggests that although observers can be trained to score reliably using observation protocols, there are concerns related to initial training and calibration activities designed to keep observers scoring accurately over time (e.g., Bell, et al, 2012; BMGF, 2012). Studies offer little insight into how…
Measuring Teaching Quality and Student Engagement in South Korea and The Netherlands
ERIC Educational Resources Information Center
van de Grift, Wim J. C. M.; Chun, Seyeoung; Maulana, Ridwan; Lee, Okhwa; Helms-Lorenz, Michelle
2017-01-01
Six observation scales for measuring the skills of teachers and 1 scale for measuring student engagement, assessed in South Korea and The Netherlands, are sufficiently reliable and offer sufficient predictive value for student engagement. A multigroup confirmatory factor analysis shows that the factor loadings and intercepts of the scales are the…
The Advance of Computing from the Ground to the Cloud
ERIC Educational Resources Information Center
Breeding, Marshall
2009-01-01
A trend toward the abstraction of computing platforms that has been developing in the broader IT arena over the last few years is just beginning to make inroads into the library technology scene. Cloud computing offers for libraries many interesting possibilities that may help reduce technology costs and increase capacity, reliability, and…
Opportunities for pulpwood growing investment in southeastern Ohio
David A. Gansner; Edgar T. Shaudys; Edgar T. Shaudys
1969-01-01
Growing hardwood trees for pulpwood offers an opportunity to overcome the objections which woodland owners have to managing their timber. Pulpwood growing is a relatively short-term venture requiring minimum investments of time, capital, and technical know-how. Also, hardwood pulpwood is likely to have reliable local market outlets in southeastern Ohio for years to...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-18
... offer their customers an increasing array of ``smartphones'' and data-centric devices, such as tablets... basis to provide service to their customers? 38. Additionally, the proposal would allow providers to... customers with comparable levels of service within that county? 40. Second, will consumers find this metric...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-06
... expectations for a safe, quality, recreational experience by providing appropriate lifts, terrain, and guest... reliability of lift and terrain offerings; (2) address skier safety concerns during prevalent wind events; (3...; (4) provide new and upgraded lift infrastructure to improve the quality of the alpine ski experience...
The Character of a Coach: Success Depends on Trustworthiness
ERIC Educational Resources Information Center
Psencik, Kay
2015-01-01
This article describes the role of coach as one that would nurture and build trust in their organization, allow others to see the coach as trustworthy, and build positive energy in the organization. The author offers some qualities that contribute to this trustworthy position, such as: self-awareness, honesty, sincerity, competence, reliability,…
ERIC Educational Resources Information Center
Flanagin, Andrew J.; Metzger, Miriam J.
2010-01-01
How well do children navigate the ocean of information that is available online? The enormous variety of Web-based resources represents both opportunities and challenges for Internet-savvy kids, offering extraordinary potential for learning and social connection but little guidance on assessing the reliability of online information. This book…
A Comprehensive Analysis of Marketing Journal Rankings
ERIC Educational Resources Information Center
Steward, Michelle D.; Lewis, Bruce R.
2010-01-01
The purpose of this study is to offer a comprehensive assessment of journal standings in Marketing from two perspectives. The discipline perspective of rankings is obtained from a collection of published journal ranking studies during the past 15 years. The studies in the published ranking stream are assessed for reliability by examining internal…
ERIC Educational Resources Information Center
Wilhelm, Anne Garrison; Kim, Sungyeun
2015-01-01
One crucial question for researchers who study teachers' classroom practice is how to maximize information about what is happening in classrooms while minimizing costs. This report extends prior studies of the reliability of the Instructional Quality Assessment (IQA), a widely used classroom observation toolkit, and offers insight into the often…
Communication Strategies for Developing Trust in the Salesperson/Prospect Exchange.
ERIC Educational Resources Information Center
Cochran, Daniel S.; Gibson, C. Kendrick
A review of literature in the sales area reveals that the communication process between salespeople and their customers is a complex one offering a wide range of relationships. To develop a feeling of trust between the two parties, salespeople can use practical communication skills emphasizing their expertness, reliability, and dynamism. Sales…
Evaluating the Performance of the IEEE Standard 1366 Method for Identifying Major Event Days
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eto, Joseph H.; LaCommare, Kristina Hamachi; Sohn, Michael D.
IEEE Standard 1366 offers a method for segmenting reliability performance data to isolate the effects of major events from the underlying year-to-year trends in reliability. Recent analysis by the IEEE Distribution Reliability Working Group (DRWG) has found that reliability performance of some utilities differs from the expectations that helped guide the development of the Standard 1366 method. This paper proposes quantitative metrics to evaluate the performance of the Standard 1366 method in identifying major events and in reducing year-to-year variability in utility reliability. The metrics are applied to a large sample of utility-reported reliability data to assess performance of themore » method with alternative specifications that have been considered by the DRWG. We find that none of the alternatives perform uniformly 'better' than the current Standard 1366 method. That is, none of the modifications uniformly lowers the year-to-year variability in System Average Interruption Duration Index without major events. Instead, for any given alternative, while it may lower the value of this metric for some utilities, it also increases it for other utilities (sometimes dramatically). Thus, we illustrate some of the trade-offs that must be considered in using the Standard 1366 method and highlight the usefulness of the metrics we have proposed in conducting these evaluations.« less
Toward lean satellites reliability improvement using HORYU-IV project as case study
NASA Astrophysics Data System (ADS)
Faure, Pauline; Tanaka, Atomu; Cho, Mengu
2017-04-01
Lean satellite programs are programs in which the satellite development philosophy is driven by fast delivery and low cost. Though this concept offers the possibility to develop and fly risky missions without jeopardizing a space program, most of these satellites suffer infant mortality and fail to achieve their mission minimum success. Lean satellites with high infant mortality rate indicate that testing prior to launch is insufficient. In this study, the authors monitored failures occurring during the development of the lean satellite HORYU-IV to identify the evolution of the cumulative number of failures against cumulative testing time. Moreover, the sub-systems driving the failures depending on the different development phases were identified. The results showed that half to 2/3 of the failures are discovered during the early stage of testing. Moreover, when the mean time before failure was calculated, it appeared that for any development phase considered, a new failure appears on average every 20 h of testing. Simulations were also performed and it showed that for an initial testing time of 50 h, reliability after 1 month launch can be improved by nearly 6 times as compared to an initial testing time of 20 h. Through this work, the authors aim at providing a qualitative reference for lean satellites developers to better help them manage resources to develop lean satellites following a fast delivery and low cost philosophy while ensuring sufficient reliability to achieve mission minimum success.
Designing for Reliability and Robustness
NASA Technical Reports Server (NTRS)
Svetlik, Randall G.; Moore, Cherice; Williams, Antony
2017-01-01
Long duration spaceflight has a negative effect on the human body, and exercise countermeasures are used on-board the International Space Station (ISS) to minimize bone and muscle loss, combatting these effects. Given the importance of these hardware systems to the health of the crew, this equipment must continue to be readily available. Designing spaceflight exercise hardware to meet high reliability and availability standards has proven to be challenging throughout the time the crewmembers have been living on ISS beginning in 2000. Furthermore, restoring operational capability after a failure is clearly time-critical, but can be problematic given the challenges of troubleshooting the problem from 220 miles away. Several best-practices have been leveraged in seeking to maximize availability of these exercise systems, including designing for robustness, implementing diagnostic instrumentation, relying on user feedback, and providing ample maintenance and sparing. These factors have enhanced the reliability of hardware systems, and therefore have contributed to keeping the crewmembers healthy upon return to Earth. This paper will review the failure history for three spaceflight exercise countermeasure systems identifying lessons learned that can help improve future systems. Specifically, the Treadmill with Vibration Isolation and Stabilization System (TVIS), Cycle Ergometer with Vibration Isolation and Stabilization System (CEVIS), and the Advanced Resistive Exercise Device (ARED) will be reviewed, analyzed, and conclusions identified so as to provide guidance for improving future exercise hardware designs. These lessons learned, paired with thorough testing, offer a path towards reduced system down-time.
The development of data acquisition and processing application system for RF ion source
NASA Astrophysics Data System (ADS)
Zhang, Xiaodan; Wang, Xiaoying; Hu, Chundong; Jiang, Caichao; Xie, Yahong; Zhao, Yuanzhe
2017-07-01
As the key ion source component of nuclear fusion auxiliary heating devices, the radio frequency (RF) ion source is developed and applied gradually to offer a source plasma with the advantages of ease of control and high reliability. In addition, it easily achieves long-pulse steady-state operation. During the process of the development and testing of the RF ion source, a lot of original experimental data will be generated. Therefore, it is necessary to develop a stable and reliable computer data acquisition and processing application system for realizing the functions of data acquisition, storage, access, and real-time monitoring. In this paper, the development of a data acquisition and processing application system for the RF ion source is presented. The hardware platform is based on the PXI system and the software is programmed on the LabVIEW development environment. The key technologies that are used for the implementation of this software programming mainly include the long-pulse data acquisition technology, multi-threading processing technology, transmission control communication protocol, and the Lempel-Ziv-Oberhumer data compression algorithm. Now, this design has been tested and applied on the RF ion source. The test results show that it can work reliably and steadily. With the help of this design, the stable plasma discharge data of the RF ion source are collected, stored, accessed, and monitored in real-time. It is shown that it has a very practical application significance for the RF experiments.
Using Mechanical Turk for research on cancer survivors.
Arch, Joanna J; Carr, Alaina L
2017-10-01
The successful recruitment and study of cancer survivors within psycho-oncology research can be challenging, time-consuming, and expensive, particularly for key subgroups such as young adult cancer survivors. Online crowdsourcing platforms offer a potential solution that has not yet been investigated with regard to cancer populations. The current study assessed the presence of cancer survivors on Amazon's Mechanical Turk (MTurk) and the feasibility of using MTurk as an efficient, cost-effective, and reliable psycho-oncology recruitment and research platform. During a <4-month period, cancer survivors living in the United States were recruited on MTurk to complete two assessments, spaced 1 week apart, relating to psychosocial and cancer-related functioning. The reliability and validity of responses were investigated. Within a <4-month period, 464 self-identified cancer survivors on MTurk consented to and completed an online assessment. The vast majority (79.09%) provided reliable and valid study data according to multiple indices. The sample was highly diverse in terms of U.S. geography, socioeconomic status, and cancer type, and reflected a particularly strong presence of distressed and young adult cancer survivors (median age = 36 years). A majority of participants (58.19%) responded to a second survey sent one week later. Online crowdsourcing represents a feasible, efficient, and cost-effective recruitment and research platform for cancer survivors, particularly for young adult cancer survivors and those with significant distress. We discuss remaining challenges and future recommendations. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Reusable Solid Rocket Motor - Accomplishment, Lessons, and a Culture of Success
NASA Technical Reports Server (NTRS)
Moore, D. R.; Phelps, W. J.
2011-01-01
The Reusable Solid Rocket Motor (RSRM) represents the largest solid rocket motor (SRM) ever flown and the only human-rated solid motor. High reliability of the RSRM has been the result of challenges addressed and lessons learned. Advancements have resulted by applying attention to process control, testing, and postflight through timely and thorough communication in dealing with all issues. A structured and disciplined approach was taken to identify and disposition all concerns. Careful consideration and application of alternate opinions was embraced. Focus was placed on process control, ground test programs, and postflight assessment. Process control is mandatory for an SRM, because an acceptance test of the delivered product is not feasible. The RSRM maintained both full-scale and subscale test articles, which enabled continuous improvement of design and evaluation of process control and material behavior. Additionally RSRM reliability was achieved through attention to detail in post flight assessment to observe any shift in performance. The postflight analysis and inspections provided invaluable reliability data as it enables observation of actual flight performance, most of which would not be available if the motors were not recovered. RSRM reusability offered unique opportunities to learn about the hardware. NASA is moving forward with the Space Launch System that incorporates propulsion systems that takes advantage of the heritage Shuttle and Ares solid motor programs. These unique challenges, features of the RSRM, materials and manufacturing issues, and design improvements will be discussed in the paper.
The private rejection of unfair offers and emotional commitment.
Yamagishi, Toshio; Horita, Yutaka; Takagishi, Haruto; Shinada, Mizuho; Tanida, Shigehito; Cook, Karen S
2009-07-14
In a series of experiments, we demonstrate that certain players of an economic game reject unfair offers even when this behavior increases rather than decreases inequity. A substantial proportion (30-40%, compared with 60-70% in the standard ultimatum game) of those who responded rejected unfair offers even when rejection reduced only their own earnings to 0, while not affecting the earnings of the person who proposed the unfair split (in an impunity game). Furthermore, even when the responders were not able to communicate their anger to the proposers by rejecting unfair offers in a private impunity game, a similar rate of rejection was observed. The rejection of unfair offers that increases inequity cannot be explained by the social preference for inequity aversion or reciprocity; however, it does provide support for the model of emotion as a commitment device. In this view, emotions such as anger or moral disgust lead people to disregard the immediate consequences of their behavior, committing them to behave consistently to preserve integrity and maintain a reputation over time as someone who is reliably committed to this behavior.