Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false Specific requirements for wireless medical... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1121 Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. Due to the critical...
47 CFR 95.1115 - General technical requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) In the 1395-1400 MHz and 1427-1432 MHz bands, no specific channels are specified. Wireless medical telemetry devices may operate on any channel within the bands authorized for wireless medical telemetry use in this part. (2) In the 608-614 MHz band, wireless medical telemetry devices utilizing broadband...
Kiourti, Asimina; Psathas, Konstantinos A; Nikita, Konstantina S
2014-01-01
Wireless medical telemetry permits the measurement of physiological signals at a distance through wireless technologies. One of the latest applications is in the field of implantable and ingestible medical devices (IIMDs) with integrated antennas for wireless radiofrequency (RF) communication (telemetry) with exterior monitoring/control equipment. Implantable medical devices (MDs) perform an expanding variety of diagnostic and therapeutic functions, while ingestible MDs receive significant attention in gastrointestinal endoscopy. Design of such wireless IIMD telemetry systems is highly intriguing and deals with issues related to: operation frequency selection, electronics and powering, antenna design and performance, and modeling of the wireless channel. In this paper, we attempt to comparatively review the current status and challenges of IIMDs with wireless telemetry functionalities. Full solutions of commercial IIMDs are also recorded. The objective is to provide a comprehensive reference for scientists and developers in the field, while indicating directions for future research. © 2013 Wiley Periodicals, Inc.
Code of Federal Regulations, 2010 CFR
2010-10-01
... wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. Due to the critical... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. 95.1121 Section 95.1121...
47 CFR 95.1111 - Frequency coordination.
Code of Federal Regulations, 2010 CFR
2010-10-01
... notify the frequency coordinator whenever a medical telemetry device is permanently taken out of service... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1111 Frequency coordination. (a) Prior to operation, authorized health care providers who desire to use wireless medical telemetry...
47 CFR 95.1111 - Frequency coordination.
Code of Federal Regulations, 2011 CFR
2011-10-01
... notify the frequency coordinator whenever a medical telemetry device is permanently taken out of service... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1111 Frequency coordination. (a) Prior to operation, authorized health care providers who desire to use wireless medical telemetry...
A system-level view of optimizing high-channel-count wireless biosignal telemetry.
Chandler, Rodney J; Gibson, Sarah; Karkare, Vaibhav; Farshchi, Shahin; Marković, Dejan; Judy, Jack W
2009-01-01
In this paper we perform a system-level analysis of a wireless biosignal telemetry system. We perform an analysis of each major system component (e.g., analog front end, analog-to-digital converter, digital signal processor, and wireless link), in which we consider physical, algorithmic, and design limitations. Since there are a wide range applications for wireless biosignal telemetry systems, each with their own unique set of requirements for key parameters (e.g., channel count, power dissipation, noise level, number of bits, etc.), our analysis is equally broad. The net result is a set of plots, in which the power dissipation for each component and as the system as a whole, are plotted as a function of the number of channels for different architectural strategies. These results are also compared to existing implementations of complete wireless biosignal telemetry systems.
Wireless powering and data telemetry for biomedical implants.
Young, Darrin J
2009-01-01
Wireless powering and data telemetry techniques for two biomedical implant studies based on (1) wireless in vivo EMG sensor for intelligent prosthetic control and (2) adaptively RF powered implantable bio-sensing microsystem for real-time genetically engineered mice monitoring are presented. Inductive-coupling-based RF powering and passive data telemetry is effective for wireless in vivo EMG sensing, where the internal and external RF coils are positioned with a small separation distance and fixed orientation. Adaptively controlled RF powering and active data transmission are critical for mobile implant application such as real-time physiological monitoring of untethered laboratory animals. Animal implant studies have been successfully completed to demonstrate the wireless and batteryless in vivo sensing capabilities.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Specific requirements for wireless medical... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1121 Specific requirements for...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1105 Eligibility. Authorized health care providers are authorized by rule to operate transmitters in the Wireless Medical Telemetry...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1103 Definitions. (a) Authorized... facility does not include an ambulance or other moving vehicle. (c) Wireless medical telemetry. The...
47 CFR 95.1115 - General technical requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 95.1115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1115... averaging detector and a 1 MHz measurement bandwidth. (c) Emission types. A wireless medical telemetry...
47 CFR 95.1115 - General technical requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 95.1115 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1115... averaging detector and a 1 MHz measurement bandwidth. (c) Emission types. A wireless medical telemetry...
47 CFR 95.1109 - Equipment authorization requirement.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Section 95.1109 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1109 Equipment authorization requirement. (a) Wireless medical telemetry devices operating under this part must...
47 CFR 95.1107 - Authorized locations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1107 Authorized locations. The operation of a wireless medical telemetry transmitter under this part is authorized anywhere within a health...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1101 Scope. This subpart sets out the regulations governing the operation of Wireless Medical Telemetry Devices in the 608-614 MHz...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1101 Scope. This subpart sets out the regulations governing the operation of Wireless Medical Telemetry Devices in the 608-614 MHz...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1101 Scope. This subpart sets out the regulations governing the operation of Wireless Medical Telemetry Devices in the 608-614 MHz...
47 CFR 95.1111 - Frequency coordination.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 47 Telecommunication 5 2014-10-01 2014-10-01 false Frequency coordination. 95.1111 Section 95.1111... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1111 Frequency coordination. (a) Prior to operation, authorized health care providers who desire to use wireless medical telemetry...
47 CFR 95.1111 - Frequency coordination.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 47 Telecommunication 5 2013-10-01 2013-10-01 false Frequency coordination. 95.1111 Section 95.1111... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1111 Frequency coordination. (a) Prior to operation, authorized health care providers who desire to use wireless medical telemetry...
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1101 Scope. This subpart sets out the regulations governing the operation of Wireless Medical Telemetry Devices in the 608-614 MHz, 1395-1400 MHz, and 1427-1432 MHz frequency bands. See § 95.630 regarding permissible frequencies. [75...
Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring.
Majerus, Steve J A; Garverick, Steven L; Suster, Michael A; Fletter, Paul C; Damaser, Margot S
2012-06-01
The wireless implantable/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9 μ A from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session.
Wireless, Ultra-Low-Power Implantable Sensor for Chronic Bladder Pressure Monitoring
MAJERUS, STEVE J. A.; GARVERICK, STEVEN L.; SUSTER, MICHAEL A.; FLETTER, PAUL C.; DAMASER, MARGOT S.
2015-01-01
The wireless implantable/intracavity micromanometer (WIMM) system was designed to fulfill the unmet need for a chronic bladder pressure sensing device in urological fields such as urodynamics for diagnosis and neuromodulation for bladder control. Neuromodulation in particular would benefit from a wireless bladder pressure sensor which could provide real-time pressure feedback to an implanted stimulator, resulting in greater bladder capacity while using less power. The WIMM uses custom integrated circuitry, a MEMS transducer, and a wireless antenna to transmit pressure telemetry at a rate of 10 Hz. Aggressive power management techniques yield an average current draw of 9 μA from a 3.6-Volt micro-battery, which minimizes the implant size. Automatic pressure offset cancellation circuits maximize the sensing dynamic range to account for drifting pressure offset due to environmental factors, and a custom telemetry protocol allows transmission with minimum overhead. Wireless operation of the WIMM has demonstrated that the external receiver can receive the telemetry packets, and the low power consumption allows for at least 24 hours of operation with a 4-hour wireless recharge session. PMID:26778926
USDA-ARS?s Scientific Manuscript database
The objectives of these experiments were to characterize rumen motility patterns of cattle fed once daily using a real-time wireless telemetry system, determine when to measure rumen motility with this system, and determine the effect of ruminal dosing of ergot alkaloids on rumen motility. Ruminally...
Flexible network wireless transceiver and flexible network telemetry transceiver
Brown, Kenneth D.
2008-08-05
A transceiver for facilitating two-way wireless communication between a baseband application and other nodes in a wireless network, wherein the transceiver provides baseband communication networking and necessary configuration and control functions along with transmitter, receiver, and antenna functions to enable the wireless communication. More specifically, the transceiver provides a long-range wireless duplex communication node or channel between the baseband application, which is associated with a mobile or fixed space, air, water, or ground vehicle or other platform, and other nodes in the wireless network or grid. The transceiver broadly comprises a communication processor; a flexible telemetry transceiver including a receiver and a transmitter; a power conversion and regulation mechanism; a diplexer; and a phased array antenna system, wherein these various components and certain subcomponents thereof may be separately enclosed and distributable relative to the other components and subcomponents.
UAV telemetry communications using ZigBee protocol
NASA Astrophysics Data System (ADS)
Nasution, T. H.; Siregar, I.; Yasir, M.
2017-10-01
Wireless communication has been widely used in various fields or disciplines such as agriculture, health, engineering, military, and aerospace so as to support the work in that field. The communication technology is typically used for controlling devices and data monitoring. One development of wireless communication is the widely used telemetry system used to reach areas that cannot be reached by humans using UAV (Unmanned Aerial Vehicle) or unmanned aircraft. In this paper we discuss the design of telemetry system in UAV using ZigBee protocol. From the test obtained the system can work well with visualization displays without pause is 20 data per second with a maximum data length of 120 characters.
NASA Astrophysics Data System (ADS)
Jia, Zhiwei; Yan, Guozheng; Zhu, Bingquan
2015-04-01
An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.
Wireless communication with implanted medical devices using the conductive properties of the body.
Ferguson, John E; Redish, A David
2011-07-01
Many medical devices that are implanted in the body use wires or wireless radiofrequency telemetry to communicate with circuitry outside the body. However, the wires are a common source of surgical complications, including breakage, infection and electrical noise. In addition, radiofrequency telemetry requires large amounts of power and results in low-efficiency transmission through biological tissue. As an alternative, the conductive properties of the body can be used to enable wireless communication with implanted devices. In this article, several methods of intrabody communication are described and compared. In addition to reducing the complications that occur with current implantable medical devices, intrabody communication can enable novel types of miniature devices for research and clinical applications.
106 17 Telemetry Standards Chapter 2
2017-07-31
high frequency STC space -time code SOQPSK shaped offset quadrature phase shift keying UHF ultra- high frequency US&P United States...and Possessions VCO voltage-controlled oscillator VHF very- high frequency WCS Wireless Communication Service Telemetry Standards, RCC Standard...get interference. a. Telemetry Bands Air and space -to-ground telemetering is allocated in the ultra- high frequency (UHF) bands 1435 to 1535, 2200
47 CFR 95.1113 - Frequency coordinator.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1113 Frequency coordinator. (a) The Commission will designate a frequency coordinator(s) to manage the usage of the frequency bands for the operation of medical telemetry devices. (b) The frequency coordinator shall (1) Review and...
A battery-free multichannel digital neural/EMG telemetry system for flying insects.
Thomas, Stewart J; Harrison, Reid R; Leonardo, Anthony; Reynolds, Matthew S
2012-10-01
This paper presents a digital neural/EMG telemetry system small enough and lightweight enough to permit recording from insects in flight. It has a measured flight package mass of only 38 mg. This system includes a single-chip telemetry integrated circuit (IC) employing RF power harvesting for battery-free operation, with communication via modulated backscatter in the UHF (902-928 MHz) band. An on-chip 11-bit ADC digitizes 10 neural channels with a sampling rate of 26.1 kSps and 4 EMG channels at 1.63 kSps, and telemeters this data wirelessly to a base station. The companion base station transceiver includes an RF transmitter of +36 dBm (4 W) output power to wirelessly power the telemetry IC, and a digital receiver with a sensitivity of -70 dBm for 10⁻⁵ BER at 5.0 Mbps to receive the data stream from the telemetry IC. The telemetry chip was fabricated in a commercial 0.35 μ m 4M1P (4 metal, 1 poly) CMOS process. The die measures 2.36 × 1.88 mm, is 250 μm thick, and is wire bonded into a flex circuit assembly measuring 4.6 × 6.8 mm.
Wireless sensors powered by microbial fuel cells.
Shantaram, Avinash; Beyenal, Haluk; Raajan, Raaja; Veluchamy, Angathevar; Lewandowski, Zbigniew
2005-07-01
Monitoring parameters characterizing water quality, such as temperature, pH, and concentrations of heavy metals in natural waters, is often followed by transmitting the data to remote receivers using telemetry systems. Such systems are commonly powered by batteries, which can be inconvenient at times because batteries have a limited lifetime and must be recharged or replaced periodically to ensure that sufficient energy is available to power the electronics. To avoid these inconveniences, a microbial fuel cell was designed to power electrochemical sensors and small telemetry systems to transmit the data acquired by the sensors to remote receivers. The microbial fuel cell was combined with low-power, high-efficiency electronic circuitry providing a stable power source for wireless data transmission. To generate enough power for the telemetry system, energy produced by the microbial fuel cell was stored in a capacitor and used in short bursts when needed. Since commercial electronic circuits require a minimum 3.3 V input and our cell was able to deliver a maximum of 2.1 V, a DC-DC converter was used to boost the potential. The DC-DC converter powered a transmitter, which gathered the data from the sensor and transmitted it wirelessly to a remote receiver. To demonstrate the utility of the system, temporal variations in temperature were measured, and the data were wirelessly transmitted to a remote receiver.
Mäntylä, Jarkko; Thomander, Tuuli; Hakulinen, Auli; Kukkonen, Kaarina; Palosuo, Kati; Voutilainen, Helena; Pelkonen, Anna; Kauppi, Paula
2018-06-01
The standard care of severe food allergy in both adults and children means avoidance of allergens. In recent years promising results of oral immunotherapy (OIT) have been reported in children. In adults, information on OIT in severe food allergy is very limited. We aimed to study if OIT is possible in adults. We report OIT results in 10 adult patients with milk OIT, nine adult patients with peanut OIT, and four adult patients with egg OIT. The allergy was confirmed with allergen specific IgE tests and oral food challenges (open in milk allergy and double-blind in peanut and egg allergy). The OIT was performed as open. The median dose of protein that led to discontinuation of allergen challenge because of symptoms was 7.5 mg in milk allergy, 25 mg in peanut allergy, and 15 mg in egg allergy. The median period of OIT was 515 days. Currently on OIT are 6/10 milk allergic patients, 4/9 peanut allergic patients and 3/4 egg allergic patients. The median dose of milk protein increased by 60-fold during OIT compared to the allergen challenge dose. In peanut OIT the median dose increased by eightfold and in egg allergy the dose increased with OIT by 35-fold. Local itching was the most common side effect of OIT (73.9% of the patients), four patients reported having used epinephrine autoinjector and three patients having needed emergency room treatment. OIT can be given in adult patients with severe milk, peanut, or egg allergy only in selected cases. OIT leads into desensitization but it is not clear whether persistent tolerance can be achieved. Mild adverse events during OIT are common. © 2018 The Authors. Immunity, Inflammation and Disease Published by John Wiley & Sons Ltd.
Wireless Command-and-Control of UAV-Based Imaging LANs
NASA Technical Reports Server (NTRS)
Herwitz, Stanley; Dunagan, S. E.; Sullivan, D. V.; Slye, R. E.; Leung, J. G.; Johnson, L. F.
2006-01-01
Dual airborne imaging system networks were operated using a wireless line-of-sight telemetry system developed as part of a 2002 unmanned aerial vehicle (UAV) imaging mission over the USA s largest coffee plantation on the Hawaiian island of Kauai. A primary mission objective was the evaluation of commercial-off-the-shelf (COTS) 802.11b wireless technology for reduction of payload telemetry costs associated with UAV remote sensing missions. Predeployment tests with a conventional aircraft demonstrated successful wireless broadband connectivity between a rapidly moving airborne imaging local area network (LAN) and a fixed ground station LAN. Subsequently, two separate LANs with imaging payloads, packaged in exterior-mounted pressure pods attached to the underwing of NASA's Pathfinder-Plus UAV, were operated wirelessly by ground-based LANs over independent Ethernet bridges. Digital images were downlinked from the solar-powered aircraft at data rates of 2-6 megabits per second (Mbps) over a range of 6.5 9.5 km. An integrated wide area network enabled payload monitoring and control through the Internet from a range of ca. 4000 km during parts of the mission. The recent advent of 802.11g technology is expected to boost the system data rate by about a factor of five.
Wireless Telemetry and Command (T and C) Program
NASA Technical Reports Server (NTRS)
Jiang, Hui; Horan, Stephen
2000-01-01
The Wireless Telemetry and Command (T&C) program is to investigate methods of using commercial telecommunications service providers to support command and telemetry services between a remote user and a base station. While the initial development is based on ground networks, the development is being done with an eye towards future space communications needs. Both NASA and the Air Force have indicated a plan to consider the use of commercial telecommunications providers to support their space missions. To do this, there will need to be an understanding of the requirements and limitations of interfacing with the commercial providers. The eventual payoff will be the reduced operations cost and the ability to tap into commercial services being developed by the commercial networks. This should enable easier realization of EP services to the end points, commercial routing of data, and quicker integration of new services into the space mission operations. Therefore, the ultimate goal of this program is not just to provide wireless radio communications for T&C services but to enhance those services through wireless networking and provider enhancements that come with the networks. In the following chapters, the detailed technical procedure will be showed step by step. Chapter 2 will talk about the general idea of simulation as well as the implementation of data acquisition including sensor array data and GPS data. Chapter 3 will talk about how to use LabVEEW and Component Works to do wireless communication simulation and how to distribute the real-time information over the Internet by using Visual Basic and ActiveX controls. Also talk about the test configuration and validation. Chapter 4 will show the test results both from In-Lab test and Networking Test. Chapter 5 will summarize the whole procedure and give the perspective for the future consideration.
Remote down-hole well telemetry
Briles, Scott D [Los Alamos, NM; Neagley, Daniel L [Albuquerque, NM; Coates, Don M [Santa Fe, NM; Freund, Samuel M [Los Alamos, NM
2004-07-20
The present invention includes an apparatus and method for telemetry communication with oil-well monitoring and recording instruments located in the vicinity of the bottom of gas or oil recovery pipes. Such instruments are currently monitored using electrical cabling that is inserted into the pipes; cabling has a short life in this environment, and requires periodic replacement with the concomitant, costly shutdown of the well. Modulated reflectance, a wireless communication method that does not require signal transmission power from the telemetry package will provide a long-lived and reliable way to monitor down-hole conditions. Normal wireless technology is not practical since batteries and capacitors have to frequently be replaced or recharged, again with the well being removed from service. RF energy generated above ground can also be received, converted and stored down-hole without the use of wires, for actuating down-hole valves, as one example. Although modulated reflectance reduces or eliminates the loss of energy at the sensor package because energy is not consumed, during the transmission process, additional stored extra energy down-hole is needed.
Wireless technologies for closed-loop retinal prostheses.
Ng, David C; Bai, Shun; Yang, Jiawei; Tran, Nhan; Skafidas, Efstratios
2009-12-01
In this paper, we discuss various technologies needed to develop retinal prostheses with wireless power and data telemetry operation. In addition to the need to communicate with the implanted device, supply of power to the retinal prosthesis is especially difficult. This is because, in the implanted state, the device is not fixed in position due to constant motion of the eye. Furthermore, a retinal prosthesis incorporating a high density electrode array of more than 1000 electrodes is expected to consume approximately 45 mW of power and require 300 kbps of image and stimulation data. The front end of the wireless power and data transmission, the antenna, needs to be small compared to the size of the eye. Also, the wireless module is expected to operate in the reactive near-field region due to small separation between the transmit and receive antennas compared to their size and corresponding operating wavelength. An inductive link is studied as a means to transfer power and for data telemetry between the implant and external unit. In this work, the use of integrated circuit and microfabrication technologies for implementing inductive links is discussed. A closed-loop approach is taken to improve performance and reach optimum operation condition. Design and simulation data are presented as the basis for development of viable wireless module prototypes.
Wireless technologies for closed-loop retinal prostheses
NASA Astrophysics Data System (ADS)
Ng, David C.; Bai, Shun; Yang, Jiawei; Tran, Nhan; Skafidas, Efstratios
2009-12-01
In this paper, we discuss various technologies needed to develop retinal prostheses with wireless power and data telemetry operation. In addition to the need to communicate with the implanted device, supply of power to the retinal prosthesis is especially difficult. This is because, in the implanted state, the device is not fixed in position due to constant motion of the eye. Furthermore, a retinal prosthesis incorporating a high density electrode array of more than 1000 electrodes is expected to consume approximately 45 mW of power and require 300 kbps of image and stimulation data. The front end of the wireless power and data transmission, the antenna, needs to be small compared to the size of the eye. Also, the wireless module is expected to operate in the reactive near-field region due to small separation between the transmit and receive antennas compared to their size and corresponding operating wavelength. An inductive link is studied as a means to transfer power and for data telemetry between the implant and external unit. In this work, the use of integrated circuit and microfabrication technologies for implementing inductive links is discussed. A closed-loop approach is taken to improve performance and reach optimum operation condition. Design and simulation data are presented as the basis for development of viable wireless module prototypes.
Aceros, Juan; Yin, Ming; Borton, David A; Patterson, William R; Nurmikko, Arto V
2011-01-01
We present a fully implantable, wireless, neurosensor for multiple-location neural interface applications. The device integrates two independent 16-channel intracortical microelectrode arrays and can simultaneously acquire 32 channels of broadband neural data from two separate cortical areas. The system-on-chip implantable sensor is built on a flexible Kapton polymer substrate and incorporates three very low power subunits: two cortical subunits connected to a common subcutaneous subunit. Each cortical subunit has an ultra-low power 16-channel preamplifier and multiplexer integrated onto a cortical microelectrode array. The subcutaneous epicranial unit has an inductively coupled power supply, two analog-to-digital converters, a low power digital controller chip, and microlaser-based infrared telemetry. The entire system is soft encapsulated with biocompatible flexible materials for in vivo applications. Broadband neural data is conditioned, amplified, and analog multiplexed by each of the cortical subunits and passed to the subcutaneous component, where it is digitized and combined with synchronization data and wirelessly transmitted transcutaneously using high speed infrared telemetry.
Aerts, Olivier; Meert, Hans; Romaen, Elien; Leysen, Julie; Matthieu, Lucretia; Apers, Sandra; Lambert, Julien; Goossens, An
2016-11-01
Octylisothiazolinone (OIT) is used as an antifungal agent by the leather industry. To show sensitization to OIT from leather, and to highlight the potential implications when cross-reactivity between OIT and methylisothiazolinone (MI) is studied. Two patients with allergic contact dermatitis caused by a leather belt and shoes, respectively, were patch tested with methylchloroisothiazolinone (MCI)/MI, MI, MCI, OIT, and benzisothiazolinone (BIT). High-performance liquid chromatography with ultraviolet detection (HPLC-UV) was used to detect isothiazolinone derivatives in leather goods. Additionally, files of OIT-sensitized patients, observed at the KU Leuven department during the period 1990-2015, were retrospectively analysed. Both patients had been primarily sensitized to OIT, but the diagnosis in one of them could be achieved only when a higher patch test concentration of OIT (1000 ppm pet.) was used. HPLC-UV confirmed the presence of OIT in their leather goods. Non-relevant sensitization to MI was noted in both cases. Four additional cases of OIT sensitization from leather could be retrieved from the KU Leuven database. Non-occupational sensitization to OIT from leather may occur. Patch test concentrations of >250 ppm pet. may be necessary for diagnosis, and to show cross-reactivity with MI. Safer use limits for OIT in the leather industry may be needed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wireless telemetry system for floating bodies
NASA Technical Reports Server (NTRS)
Fain, L. T.; Cribb, H. E.
1974-01-01
Unit includes rugged waterproof cables and equipment containers, low power, sturdy antenna construction, and easy equipment setup and serviceability. Accuracy and reliability of entire measurement system were not sacrificed.
Allergist-reported trends in the practice of food allergen oral immunotherapy.
Greenhawt, Matthew J; Vickery, Brian P
2015-01-01
Food allergen oral immunotherapy (OIT) is an experimental, immune-modifying therapy that may induce clinical desensitization in some patients. OIT is still in early phase clinical research, but some providers may offer OIT as a clinical service. To understand the current practices of allergists who perform OIT, an online survey was sent by e-mail to members of the American Academy of Allergy Asthma & Immunology. Among 442 respondents, 61 reported participating in using OIT (13.8%), including 28 in nonacademic settings. Informed consent for OIT was obtained by 91.3%, institutional review board approval by 47.7% and Investigational New Drug approval by 38.1%. Compared with nonacademic participants, more academic participants used peanut OIT, obtained institutional review board and Investigational New Drug (P < .0001 respectively), and challenged patients before entry (P = .008). More nonacademic providers billed the patient or insurance for reimbursement (P < .0001). Low reported regard for the importance for US Food and Drug Administration approval or a standardized product (increased odds), and a high regard for better safety data (decreased odds) were associated with considering offering OIT as a service. Significant differences exist with OITs that occur in academic versus nonacademic settings. Further assessment is needed regarding the different motivations and practice styles among providers who offer OIT and those who are considering doing so. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Zaman, Afroz; Bauch, Matthew; Raible, Daniel
2011-01-01
Aircraft engines have evolved into a highly complex system to meet ever-increasing demands. The evolution of engine technologies has primarily been driven by fuel efficiency, reliability, as well as engine noise concerns. One of the sources of engine noise is pressure fluctuations that are induced on the stator vanes. These local pressure fluctuations, once produced, propagate and coalesce with the pressure waves originating elsewhere on the stator to form a spinning pressure pattern. Depending on the duct geometry, air flow, and frequency of fluctuations, these spinning pressure patterns are self-sustaining and result in noise which eventually radiate to the far-field from engine. To investigate the nature of vane pressure fluctuations and the resulting engine noise, unsteady pressure signatures from an array of embedded acoustic sensors are recorded as a part of vane noise source diagnostics. Output time signatures from these sensors are routed to a control and data processing station adding complexity to the system and cable loss to the measured signal. "Smart" wireless sensors have data processing capability at the sensor locations which further increases the potential of wireless sensors. Smart sensors can process measured data locally and transmit only the important information through wireless communication. The aim of this wireless noise telemetry task was to demonstrate a single acoustic sensor wireless link for unsteady pressure measurement, and thus, establish the feasibility of distributed smart sensors scheme for aircraft engine vane surface unsteady pressure data transmission and characterization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott G. Bauer; Matthew O. Anderson; James R. Hanneman
2005-10-01
The proven value of DOD Unmanned Aerial Vehicles (UAVs) will ultimately transition to National and Homeland Security missions that require real-time aerial surveillance, situation awareness, force protection, and sensor placement. Public services first responders who routinely risk personal safety to assess and report a situation for emergency actions will likely be the first to benefit from these new unmanned technologies. ‘Packable’ or ‘Portable’ small class UAVs will be particularly useful to the first responder. They require the least amount of training, no fixed infrastructure, and are capable of being launched and recovered from the point of emergency. All UAVs requiremore » wireless communication technologies for real- time applications. Typically on a small UAV, a low bandwidth telemetry link is required for command and control (C2), and systems health monitoring. If the UAV is equipped with a real-time Electro-Optical or Infrared (EO/Ir) video camera payload, a dedicated high bandwidth analog/digital link is usually required for reliable high-resolution imagery. In most cases, both the wireless telemetry and real-time video links will be integrated into the UAV with unity gain omni-directional antennas. With limited on-board power and payload capacity, a small UAV will be limited with the amount of radio-frequency (RF) energy it transmits to the users. Therefore, ‘packable’ and ‘portable’ UAVs will have limited useful operational ranges for first responders. This paper will discuss the limitations of small UAV wireless communications. The discussion will present an approach of utilizing a dynamic ground based real-time tracking high gain directional antenna to provide extend range stand-off operation, potential RF channel reuse, and assured telemetry and data communications from low-powered UAV deployed wireless assets.« less
Spectrum Efficiency Through Dynamic Spectrum Access Techniques (Briefing Charts)
2014-06-01
Telemetry Data Sources IP BASED TELEMETRY STATION Flow control • Volume- based • Credit- based • Rate- based Signaling using custom protocols or standards...Responsible for all T&E infrastructure assessment within the Major Range and Test Facility Base (MRTFB) DoD Directive 3200.11 • Administer three...Memorandum Unleashing of the Wireless Broadband Revolution THE WHY: Based on the view that “we are now beginning the next transformation in
Side effects and their impact on the success of milk oral immunotherapy (OIT) in children
Mori, Francesca; Cianferoni, Antonella; Brambilla, Alice; Barni, Simona; Sarti, Lucrezia; Pucci, Neri; de Martino, Maurizio; Novembre, Elio
2017-01-01
Oral immunotherapy (OIT) has been introduced as a new immune-modulating treatment under investigation for food allergies. The aim of our study was to evaluate the success of OIT in a cohort of children with milk allergy. These children underwent OIT in a clinical practice and were followed for up to ten years. The secondary endpoint was to describe the main adverse events during OIT and compare them to those reported in the literature. Eighty-two milk-allergic children started OIT. According to the OIT endpoint reached after one year, all of the children enrolled in the study were divided into four groups: complete desensitization; partial desensitization; step down; and stop groups. Any adverse events that occurred during OIT were also recorded. Of the 82 patients, eight were recruited in the last months of 2010 so they were still ongoing at the end of the study. For that reason, they were excluded from the analysis. The majority (73%) of the 74 children evaluated (51 boys, 23 girls; median age, 7 years; age range, 2–18 years; specific serum IgE for cow’s milk, 36 KUA/L [range, 3–100 KUA/L]; milk SPT wheal diameter, 7 mm [range, 2–15 mm]) reached complete (58.1%) or partial (14.9%) desensitization, 9.4% were subjected to step down. The remaining 17.6% of the children discontinued OIT because of the occurrence of chronic gastroenteric (GE) symptoms (46.1%) or acute asthma (15.3%) following milk intake. In agreement with the literature, we found that chronic GE symptoms was the main reason for OIT discontinuation. OIT represents a valid tool for the treatment of food allergies in children; however, the risk of potential adverse reactions, both IgE- and non-IgE-mediated, should be discussed with parents prior to the initiation of OIT. PMID:28466667
Varshney, Pooja; Jones, Stacie M.; Scurlock, Amy M.; Perry, Tamara T.; Kemper, Alex; Steele, Pamela; Hiegel, Anne; Kamilaris, Janet; Carlisle, Suzanne; Yue, Xiaohong; Kulis, Mike; Pons, Laurent; Vickery, Brian; Burks, A. Wesley
2011-01-01
Background Open-label oral immunotherapy (OIT) protocols have been used to treat small numbers of patients with peanut allergy. Peanut OIT has not been evaluated in double-blind, placebo-controlled trials. Objective To investigate the safety and effectiveness of OIT for peanut allergy in a double blind, placebo-controlled study. Methods In this multicenter study, peanut-allergic children ages 1-16 years received OIT with peanut flour or placebo. Initial escalation, build-up, and maintenance phases were followed by an oral food challenge at approximately one year. Titrated skin prick tests (SPT) and laboratory studies were performed at regular intervals. Results Twenty-eight subjects were enrolled in the study. Three peanut OIT subjects withdrew early in the study due to allergic side effects. During the double-blind, placebo-controlled food challenge, all remaining peanut OIT subjects (N=16) ingested the maximum cumulative dose of 5000 mg (approximately 20 peanuts), while placebo subjects (N=9) ingested a median cumulative dose of 280 mg (range, 0-1900 mg) [p<0.001]. In contrast to the placebo group, the peanut OIT group showed reductions in SPT size (p<0.001), IL-5 (p=0.01), and IL-13 (p=0.02) and increases in peanut-specific IgG4 (p<0.001). Peanut OIT subjects had initial increases in peanut-specific IgE (p<0.01) but did not show significant change from baseline by the time of OFC. The ratio of FoxP3 hi: FoxP3 intermediate CD4+CD25+ T cells increased at the time of OFC (p=0.04) in peanut OIT subjects. Conclusion These results conclusively demonstrate that peanut OIT induces desensitization and concurrent immune modulation. The present study continues and is evaluating the hypothesis that peanut OIT causes long-term immune tolerance. PMID:21377034
NASA Technical Reports Server (NTRS)
1984-01-01
L & M Electronics, Inc.'s telemetry system is used to measure degree and location of abnormal muscle activity. This telemetry was originally used to monitor astronauts vital functions. Leg sensors send wireless signals to computer which develops pictures of gait patterns. System records, measures and analyzes muscle activities in limbs and spine. Computer developed pictures of gait patterns help physicians determine potential of corrective surgery, evaluate various types of braces, or decide whether physical therapy may improve motor functions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jia, Zhiwei, E-mail: jiayege@hotmail.com; Yan, Guozheng; Zhu, Bingquan
An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome themore » power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.« less
Effect of ketotifen premedication on adverse reactions during peanut oral immunotherapy
2014-01-01
Background Oral immunotherapy (OIT) has shown promise in inducing desensitization for food allergy. However, there are safety concerns regarding the frequency and severity of adverse events during food OIT. Objective To evaluate the effect of Ketotifen premedication on adverse reactions during peanut OIT. Methods A randomized single blind placebo controlled pilot study was performed. Peanut OIT was performed using a previously published protocol. Ketotifen was up-titrated to 2 mg twice daily over two weeks (week -2 to 0), followed by a peanut OIT initial escalation day (day 1). Ketotifen was administered from week 0–4 of peanut OIT; reactions to peanut OIT doses were recorded by clinic staff and subject diary. Results Six subjects (median age 10 years, peanut IgE >100kUA/L) were enrolled, 4 randomized to Ketotifen, 2 to placebo. The most common side effect of Ketotifen was fatigue (9% during up-titration). The rate of reaction per peanut OIT dose was lower for subjects on ketotifen (K) compared to placebo (P) during initial escalation on day 1 (K: 22% (8/36) vs. P: 67% (12/18)); week 0–4 build-up doses (K: 75% (3/4) vs. P: 100% (2/2)); and week 0–4 home doses (K: 50% (54/108) vs. P: 82% (27/33)). The rate of gastrointestinal symptoms per peanut OIT dose was also lower for subjects on ketotifen during initial escalation on day 1 (K: 17% (6/36) vs. P: 61% (11/18)); week 0–4 build-up doses (K: 75% (3/4) vs P: 100% (2/2)); and week 0–4 home doses (K: 46% (50/108) vs. P: 82% (27/33)). Conclusions Ketotifen premedication is well tolerated and reduces the rate of gastrointestinal symptoms during peanut OIT. These findings require confirmation in a larger study of Ketotifen premedication used throughout peanut OIT. Trial registration Clinical Trials number: NCT0162515 PMID:25031584
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1103 Definitions. (a) Authorized... in rendering medical treatment, and institutions and organizations regularly engaged in providing medical services through clinics, public health facilities, and similar establishments, including...
47 CFR 95.601 - Basis and purpose.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Radio Service)—subpart C, the CB (Citizens Band Radio Service)—subpart D, the Low Power Radio Service (LPRS)—subpart G, the Wireless Medical Telemetry Service (WMTS)—subpart H, the Medical Device...
Immunotherapy for cow's milk allergy
Takahashi, Masaya; Soejima, Kazukiko; Hatano, Yasuko; Minami, Hirotaka
2017-01-01
ABSTRACT Oral immunotherapy (OIT) is used regularly for young children with cow's milk (CM) allergy and has been shown to be effective in several studies. However, adverse events occur frequently during OIT. Furthermore, there are only 5 randomized controlled trial studies of CM-OIT and these are low-powered single center trials. Therefore, evidence levels are also low and sometimes frequent and severe allergic events occur during the OIT. Furthermore, there are no standardized protocols in pediatric allergy guidelines from several countries and studies with long-term follow-up observations and clinical tolerance defined as sustained unresponsiveness are rare. Additionally, clinical tolerance by OIT is generally not well defined and obscure. Thus, several problems remain to be resolved, however we hope OIT in combination with omalizumab and less allergenic heated CM products will resolve these problems in the future. PMID:28825866
Changes in biomarkers during a six-month oral immunotherapy intervention for cow's milk allergy.
Salmivesi, Susanna; Paassilta, Marita; Huhtala, Heini; Nieminen, Riina; Moilanen, Eeva; Korppi, Matti
2016-11-01
Oral immunotherapy (OIT) is a promising but still experimental method to treat children with cow's milk (CM) allergy (CMA). We evaluated changes in allergic, immunological and inflammatory parameters, which happened during the six-month OIT for CMA. We treated 28 school-aged children with CMA using OIT with a double-blind placebo-controlled design. After the controlled study finished, the placebo group was treated with the same but open-label OIT protocol. Sixteen immune variables were tested before and after the six-month OIT. Before OIT, the median serum CM-specific immunoglobulin (Ig) E was 18.0kIU/L in the intervention group and 9.4kIU/L in the placebo group (p = 0.46). At six months, interleukin (IL)-6 and IL-10 were significantly higher in the intervention group. When the changes during the blinded and open OIT were analysed together for both groups, blood eosinophils and serum total IgE decreased and milk-specific IgG and IgG4, serum IL-4 and IL-6, and serum leptin and resistin increased significantly. Preliminary evidence was found that markers of allergy such as blood eosinophils and serum IgE decreased and milk-specific IgG and IgG4 increased during OIT. Adipokines, leptin and resistin, which functionally are cytokines linked to Th1-type response, increased during OIT. ©2016 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Krueger, Chad A; Shakir, Irshad; Fuller, Brian C
2012-09-01
One of the greatest predictors for resident success on the Orthopaedic In-Training Examination (OITE) is reviewing previous OITE questions. However, no studies have examined which review sources contain the most answers to previously asked OITE questions. The goal of this study was to determine which review source contains the most answers to previously asked OITE questions. Each question from the 2006 to 2010 OITEs was examined. The questions were placed into 1 of 13 categories based on their topic. The publication date of the recommended readings associated with each question was recorded. The answer to each question was then searched for in 3 commonly used review sources: Miller's Review of Orthopaedics, 5th edition (MRO), American Academy of Orthopaedic Surgeons Comprehensive Orthopaedic Review (COR), and www.orthobullets.com (OB). Searchable electronic versions of each textbook were used, and each question had a 12-minute time limit. Of 1358 questions, 665 (49%) were found in all 3 sources. Significantly more answers were found on OB (99.4%) compared with MRO (60%) and COR (62%) (P<.0001). Significantly more answers to questions in each question category were found on OB compared with MRO or COR (P<.0001). More than 50% of all recommended readings for OITE questions were published within 5 years of the OITE. Residents using OB to review for the OITE will be exposed to significantly more answers of previously asked OITE questions than residents using MRO or COR (P<.0001). Copyright 2012, SLACK Incorporated.
Radio telemetry devices to monitor breathing in non-sedated animals.
Samson, Nathalie; Dumont, Sylvain; Specq, Marie-Laure; Praud, Jean-Paul
2011-12-15
Radio telemetry equipment has significantly improved over the last 10-15 years and is increasingly being used in research for monitoring a variety of physiological parameters in non-sedated animals. The aim of this review is to provide an update on the current state of development of radio telemetry for recording respiration. Our literature review found only rare reports of respiratory studies via radio telemetry. Much of this article will hence report our experience with our custom-built radio telemetry devices designed for recording respiratory signals, together with numerous other physiological signals in lambs. Our current radio telemetry system allows to record 24 simultaneous signals 24h/day for several days. To our knowledge, this is the highest number of physiological signals, which can be recorded wirelessly. Our devices have been invaluable for studying respiration in our ovine models of preterm birth, reflux laryngitis, postnatal exposure to cigarette smoke, respiratory syncytial virus infection and nasal ventilation, all of which are relevant to neonatal respiratory problems. Copyright © 2011 Elsevier B.V. All rights reserved.
Frischmeyer-Guerrerio, Pamela A.; Keet, Corinne A.; Guerrerio, Anthony L.; Chichester, Kristin L.; Bieneman, Anja P.; Hamilton, Robert G.; Wood, Robert A.; Schroeder, John T.
2014-01-01
Sublingual (SLIT) and oral immunotherapy (OIT) are promising treatments for food allergy, but underlying mechanisms are poorly understood. Dendritic cells (DC) induce and maintain Th2-type allergen-specific T cells, and also regulate innate immunity through their expression of Toll-like receptors (TLRs). We examined how SLIT and OIT influenced DC innate and adaptive immune responses in children with IgE-mediated cow's milk (CM) allergy. SLIT, but not OIT, decreased TLR-induced IL-6 secretion by myeloid DCs (mDCs). SLIT and OIT altered mDC IL-10 secretion, a potent inhibitor of FcεRI-dependent pro-inflammatory responses. OIT uniquely augmented IFN-α and decreased IL-6 secretion by plasmacytoid DCs (pDCs), which was associated with reduced TLR-induced IL-13 release in pDC-T cell co-cultures. Both SLIT and OIT decreased Th2 cytokine secretion to CM in pDC-T, but not mDC-T, co-cultures. Therefore, SLIT and OIT exert unique effects on DC-driven innate and adaptive immune responses, which may inhibit allergic inflammation and promote tolerance. PMID:25173802
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bevly, III, Alex J.; McConkey, Joshua S.
In a telemetry system (100) in a high-temperature environment of a combustion turbine engine (10), a wireless power-receiving coil assembly (116) may be affixed to a movable component (104) of the turbine engine. Power-receiving coil assembly (116) may include a radio-frequency transparent housing (130) having an opening (132). A lid (134) may be provided to close the opening of the housing. Lid (134) may be positioned to provide support against a surface (120) of the movable component. An induction coil (133) is disposed in the housing distally away from the lid and encased between a first layer (136) and amore » last layer (140) of a potting adhesive. Lid (134) is arranged to provide vibrational buffering between the surface (120) of the movable component (104) and the layers encasing the induction coil.« less
Electromagnetic limits to radiofrequency (RF) neuronal telemetry.
Diaz, R E; Sebastian, T
2013-12-18
The viability of a radiofrequency (RF) telemetry channel for reporting individual neuron activity wirelessly from an embedded antenna to an external receiver is determined. Comparing the power at the transmitting antenna required for the desired Channel Capacity, to the maximum power that this antenna can dissipate in the body without altering or damaging surrounding tissue reveals the severe penalty incurred by miniaturization of the antenna. Using both Specific Absorption Rate (SAR) and thermal damage limits as constraints, and 300 Kbps as the required capacity for telemetry streams 100 ms in duration, the model shows that conventional antennas smaller than 0.1 mm could not support human neuronal telemetry to a remote receiver (1 m away.) Reducing the antenna to 10 microns in size to enable the monitoring of single human neuron signals to a receiver at the surface of the head would require operating with a channel capacity of only 0.3 bps.
Photodegradation of octylisothiazolinone and semi-field emissions from facade coatings
NASA Astrophysics Data System (ADS)
Bollmann, Ulla E.; Minelgaite, Greta; Schlüsener, Michael; Ternes, Thomas A.; Vollertsen, Jes; Bester, Kai
2017-01-01
Amongst others, 2-octyl-isothiazol-3(2 H)-one (OIT) is used as film preservative in water-based polymer resin paints and renders to prevent the growth of moulds and bacteria. It is known that biocides leach from facades with rainwater and end up in the environment via stormwater runoff. In the present study the leaching and fate of OIT used in facade coatings was determined under natural conditions. Potential phototransformation products were initially identified in laboratory experiments using UV-light. Afterwards, the leaching of OIT and seven degradation products were studied on artificial walls equipped with organic top coatings formulated with OIT. A mass balance, including the leached and remaining amounts of OIT and its seven transformation products, can explain up to 40% of the initial amount of OIT. The OIT remaining in the material after 1.5 yr is by far the largest fraction. The study shows that in the assessment of biocides in coating material, transformation products need to be taken into account both in leachate and remaining in the material. Furthermore, in case of volatile degradation products, the emissions to air might be relevant.
Photodegradation of octylisothiazolinone and semi-field emissions from facade coatings.
Bollmann, Ulla E; Minelgaite, Greta; Schlüsener, Michael; Ternes, Thomas A; Vollertsen, Jes; Bester, Kai
2017-01-27
Amongst others, 2-octyl-isothiazol-3(2 H)-one (OIT) is used as film preservative in water-based polymer resin paints and renders to prevent the growth of moulds and bacteria. It is known that biocides leach from facades with rainwater and end up in the environment via stormwater runoff. In the present study the leaching and fate of OIT used in facade coatings was determined under natural conditions. Potential phototransformation products were initially identified in laboratory experiments using UV-light. Afterwards, the leaching of OIT and seven degradation products were studied on artificial walls equipped with organic top coatings formulated with OIT. A mass balance, including the leached and remaining amounts of OIT and its seven transformation products, can explain up to 40% of the initial amount of OIT. The OIT remaining in the material after 1.5 yr is by far the largest fraction. The study shows that in the assessment of biocides in coating material, transformation products need to be taken into account both in leachate and remaining in the material. Furthermore, in case of volatile degradation products, the emissions to air might be relevant.
Photodegradation of octylisothiazolinone and semi-field emissions from facade coatings
Bollmann, Ulla E.; Minelgaite, Greta; Schlüsener, Michael; Ternes, Thomas A.; Vollertsen, Jes; Bester, Kai
2017-01-01
Amongst others, 2-octyl-isothiazol-3(2 H)-one (OIT) is used as film preservative in water-based polymer resin paints and renders to prevent the growth of moulds and bacteria. It is known that biocides leach from facades with rainwater and end up in the environment via stormwater runoff. In the present study the leaching and fate of OIT used in facade coatings was determined under natural conditions. Potential phototransformation products were initially identified in laboratory experiments using UV-light. Afterwards, the leaching of OIT and seven degradation products were studied on artificial walls equipped with organic top coatings formulated with OIT. A mass balance, including the leached and remaining amounts of OIT and its seven transformation products, can explain up to 40% of the initial amount of OIT. The OIT remaining in the material after 1.5 yr is by far the largest fraction. The study shows that in the assessment of biocides in coating material, transformation products need to be taken into account both in leachate and remaining in the material. Furthermore, in case of volatile degradation products, the emissions to air might be relevant. PMID:28128314
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Hall, David G.; Miranda, Felix A.
2004-01-01
The paper describes the operation of a patented wireless RF telemetry system, consisting of a bio-MEMS implantable sensor and an external hand held unit, operating over the frequency range of few hundreds of MHz. A MEMS capacitive pressure sensor integrated with a miniature inductor/antenna together constitute the implantable sensor. Signal processing circuits collocated with a printed loop antenna together form the hand held unit, capable of inductively powering and also receiving the telemetry signals from the sensor. The paper in addition, demonstrates a technique to enhance the quality factor and inductance of the inductor in the presence of a lower ground plane and also presents the radiation characteristics of the loop antenna.
Integrating legacy medical data sensors in a wireless network infrastucture.
Dembeyiotis, S; Konnis, G; Koutsouris, D
2005-01-01
In the process of developing a wireless networking solution to provide effective field-deployable communications and telemetry support for rescuers during major natural disasters, we are faced with the task of interfacing the multitude of medical and other legacy data collection sensors to the network grid. In this paper, we detail a number of solutions, with particular attention given to the issue of data security. The chosen implementation allows for sensor control and management from remote network locations, while the sensors can wirelessly transmit their data to nearby network nodes securely, utilizing the latest commercially available cryptography solutions. Initial testing validates the design choices, while the network-enabled sensors are being integrated in the overall wireless network security framework.
Safety and Efficacy of Low-Dose Oral Immunotherapy for Hen's Egg Allergy in Children.
Yanagida, Noriyuki; Sato, Sakura; Asaumi, Tomoyuki; Nagakura, Kenichi; Ogura, Kiyotake; Ebisawa, Motohiro
2016-01-01
The minimal dose for oral immunotherapy (OIT) tolerance is unknown. We investigated the efficacy and safety of low-dose OIT with 1/32 of the volume of a whole egg. Thirty-three children (aged ≥5 years) with egg allergies confirmed by oral food challenge against 1/32 of a heated whole egg (194 mg of egg protein) were enrolled. The OIT group ingested a scrambled egg once a day. The volume was gradually increased up to a maximum of 1/32 of a heated whole egg. Egg consumption was completely absent in the control group. There were no significant differences in background between the OIT and control groups. Respectively, 71% (15/21) and 0% (0/12) of the patients in the OIT and control groups exhibited sustained unresponsiveness to 1/32 of a whole egg 2 weeks after stopping OIT after 12 months (p < 0.001); 33% (7/21) and 0% (0/12; p = 0.032), respectively, showed sustained unresponsiveness to 1/2 of a whole egg. Egg white- or ovomucoid-specific IgE levels in the OIT group were significantly lower than at baseline after 12 months. Egg white- or ovomucoid-specific IgG as well as IgG4 levels in the OIT group were significantly higher than baseline levels after 1, 3, 6, and 12 months. Adverse allergic reactions were rare, and most symptoms were mild. Low-dose OIT induced sustained unresponsiveness to 1/32 and 1/2 of a whole egg, with no severe symptoms. To improve food allergies, continuous intake of small amounts of these foods may be as effective as the consumption of larger quantities. © 2017 The Author(s) Published by S. Karger AG, Basel.
30 pJ/b, 67 Mbps, Centimeter-to-Meter Range Data Telemetry With an IR-UWB Wireless Link.
Ebrazeh, Ali; Mohseni, Pedram
2015-06-01
This paper reports an energy-efficient, impulse radio ultra wideband (IR-UWB) wireless link operating in 3-5 GHz for data telemetry over centimeter-to-meter range distances at rates extended to tens of Mbps. The link comprises an all-digital, integrated transmitter (TX) fabricated in 90 nm 1P/9M CMOS that incorporates a waveform-synthesis pulse generator and a timing generator for on-off-keying (OOK) pulse modulation and phase scrambling. The link also incorporates an energy-detection receiver (RX) realized with commercial off-the-shelf (COTS) components that performs radio-frequency (RF) filtering, amplification, logarithmic power detection for data demodulation and automatic level control for robust operation in the presence of distance variations. Employing a miniaturized, UWB, chip antenna for the TX and RX, wireless transmission of pseudo-random binary sequence (PRBS) data at rates up to 50 Mbps over 10 cm-1 m is shown. Further, employing a high-gain horn antenna for the RX, wireless transmission of PRBS data at rates up to 67 Mbps over 50 cm-4 m is shown with a TX energy consumption of 30 pJ/b (i.e., power consumption of 2 mW) from 1.2 V. The measured bit error rate (BER) in both cases is < 10(-7) . Results from wireless recording of the background current of a carbon-fiber microelectrode (CFM) in one fast-scan cyclic voltammetry (FSCV) scan using the IR-UWB link are also included, exhibiting excellent match with those obtained from a conventional frequency-shift-keyed (FSK) link at ~433 MHz.
47 CFR 95.1127 - Station identification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Station identification. 95.1127 Section 95.1127 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1127 Station identification. A...
47 CFR 95.1113 - Frequency coordinator.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1113 Frequency coordinator. (a... with radio astronomy observatories and Federal Government radar systems as specified in §§ 95.1119 and...
47 CFR 95.1113 - Frequency coordinator.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1113 Frequency coordinator. (a... with radio astronomy observatories and Federal Government radar systems as specified in §§ 95.1119 and...
47 CFR 95.1129 - Station inspection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Station inspection. 95.1129 Section 95.1129 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1129 Station inspection. All...
47 CFR 95.1107 - Authorized locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false Authorized locations. 95.1107 Section 95.1107 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1107 Authorized locations. The...
OIT Times--Summer 2001, Vol. 4, No. 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2001-06-01
Summer 2001 edition of the OIT Times newsletter, an 8-page quarterly publication produced by the Office of Industrial Technologies. This issue covers the return on federal investment in OIT-sponsored R&D technologies and contains lists of emerging technologies in each Industry of the Future.
Progressively Communicating Rich Telemetry from Autonomous Underwater Vehicles via Relays
2012-06-01
wireless sensor networks using an autonomous underwater vehicle. In Robotics and...communication over multiple kilometers. In addition to wireless com- munication methods , the recently developed Nereus[12] vehicle at WHOI spools out...A P T U R E M e ss a g e s P ro ce ss / T h re a d M a n a g e m e n t C o n fi g u ra ti o n P a rs in g Network Manager Frame Scheduling
Wireless pilot monitoring system for extreme race conditions.
Pino, Esteban J; Arias, Diego E; Aqueveque, Pablo; Melin, Pedro; Curtis, Dorothy W
2012-01-01
This paper presents the design and implementation of an assistive device to monitor car drivers under extreme conditions. In particular, this system is designed in preparation for the 2012 Atacama Solar Challenge to be held in the Chilean desert. Actual preliminary results show the feasibility of such a project including physiological and ambient sensors, real-time processing algorithms, wireless data transmission and a remote monitoring station. Implementation details and field results are shown along with a discussion of the main problems found in real-life telemetry monitoring.
Clinical Efficacy and Immune Regulation With Peanut Oral Immunotherapy
Jones, Stacie M.; Pons, Laurent; Roberts, Joseph L.; Scurlock, Amy M.; Perry, Tamara T.; Kulis, Mike; Shreffler, Wayne G.; Steele, Pamela; Henry, Karen A.; Adair, Margaret; Francis, James M.; Durham, Stephen; Vickery, Brian P.; Zhong, Xiaoping; Burks, A. Wesley
2009-01-01
Background Oral immunotherapy (OIT) has been thought to induce clinical desensitization to allergenic foods, but trials coupling the clinical response and immunologic effects of peanut OIT have not been reported. Objective The study objective was to investigate the clinical efficacy and immunologic changes associated with OIT. Methods Peanut-allergic children underwent an OIT protocol including initial day escalation, build-up, and maintenance phases, and then oral food challenge. Clinical response and immunologic changes were evaluated. Results Of 29 subjects who completed the protocol, 27 ingested 3.9 g peanut protein during food challenge. Most symptoms noted during OIT resolved spontaneously or with antihistamines. By 6 months, titrated skin prick tests and activation of basophils significantly declined. Peanut-specific IgE decreased by 12–18 months, while IgG4 increased significantly. Serum factors inhibited IgE–peanut complex formation in an IgE-facilitated allergen binding assay. Secretion of IL-10, IL-5, IFN-γ, and TNF-α from PBMCs increased over 6–12 months. Peanut-specific FoxP3 T cells increased until 12 months and then decreased thereafter. Additionally, T cell microarrays showed downregulation of genes in apoptotic pathways. Conclusion OIT induces clinical desensitization to peanut, with significant longer term humoral and cellular changes. Microarray data suggest a novel role for apoptosis in OIT. PMID:19577283
Code of Federal Regulations, 2011 CFR
2011-10-01
... 47 Telecommunication 5 2011-10-01 2011-10-01 false RF safety. 95.1125 Section 95.1125 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1125 RF safety. Portable devices...
47 CFR 95.1117 - Types of communications.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Types of communications. 95.1117 Section 95.1117 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1117 Types of...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 5 2010-10-01 2010-10-01 false RF safety. 95.1125 Section 95.1125 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1125 RF safety. Portable devices...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO... health care providers are authorized by rule to operate transmitters in the Wireless Medical Telemetry... authorized health care providers. No entity that is a foreign government or which is active in the capacity...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO... health care providers are authorized by rule to operate transmitters in the Wireless Medical Telemetry... authorized health care providers. No entity that is a foreign government or which is active in the capacity...
Yen, David; Athwal, George S; Cole, Gary
2014-08-01
Positive correlation between the orthopedic in-training examination (OITE) and success in the American Board of Orthopaedic Surgery examination has been reported. Canadian training programs in internal medicine, anesthesiology and urology have found a positive correlation between in-training examination scores and performance on the Royal College of Physicians and Surgeons of Canada (RCPSC) certification examination. We sought to determine the potential predictive value of the OITE scores of Canadian orthopedic surgery residents on their success on their RCPSC examinations. A total of 118 Canadian orthopedic surgery residents had their annual OITE scores during their 5 years of training matched to the RCPSC examination oral and multiple-choice questions and to overall examination pass/fail scores. We calculated Pearson correlations between the in-training examination for each postgraduate year and the certification oral and multiple-choice questions and pass/fail marks. There was a predictive association between the OITE and success on the RCPSC examination. The association was strongest between the OITE and the written multiple-choice examination and weakest between the OITE and the overall examination pass/fail marks. Overall, the OITE was able to provide useful feedback to Canadian orthopedic surgery residents and their training programs in preparing them for their RCPSC examinations. However, when these data were collected, truly normative data based on a Canadian sample were not available. Further study is warranted based on a more refined analysis of the OITE, which is now being produced and includes normative percentile data based on Canadian residents.
Roberts, Craig S; Nyland, John; Broome, Brandon
2012-04-01
To determine the efficacy of an educational curriculum designed for orthopedic surgery postgraduate year 1 (PGY-1) interns to improve initial Orthopedic In-Training Examination (OITE) performance. A retrospective cohort study was performed that evaluated the PGY-1 intern OITE performance of one residency training program (n = 55) during 7-year periods before (1996-2002) and after structured curriculum implementation (2003-2009). Linear regression analysis revealed insignificant changes in median PGY-1 intern OITE percentile rank during the precurriculum period (R = 0.08, P = 0.53). Postcurriculum period comparisons revealed significantly improving PGY-1 intern OITE percentile rank (R = 0.46, P = 0.048). Pre- and postcurriculum median US Medical Licensing Examination (USMLE) Step I scores did not display statistically significant differences (218.2 ± 6.6 vs 229.1 ± 13.8, Mann-Whitney U test, z = -1.5, P = 0.10). Spearman rho correlations revealed a moderate relation (r = 0.61) between postcurriculum PGY-1 intern OITE percentile rank and USMLE Step I score, but not during the precurriculum period. A moderate relation (r = 0.50) also was observed between postcurriculum USMLE Step I score and average OITE percentile rank during the 5-year residency program, but not during the precurriculum period. PGY-1 intern OITE percentile rank improved significantly with the addition of a specially designed educational curriculum. The stronger USMLE Step I score and PGY-1 intern OITE percentile rank relation observed during the postcurriculum period suggests that interns who participated in the educational curriculum were better prepared to translate general medical and patient care knowledge into orthopedic surgery knowledge.
Bluetooth telemetry system for a wearable electrocardiogram
NASA Astrophysics Data System (ADS)
Green, Ryan B.
The rise of wireless networks has led to a new market in medicine: remote patient monitoring. Practitioners now desire to monitor the health conditions of their patients after hospital release. With the large number of cardiac related deaths and this new demand in medicine being the motivation, this study developed a BluetoothRTM telemetry system for a wearable Electrocardiogram. This study also developed a compression t-shirt to hold the ECG and telemetry system. This device communicates the ECG signal of a patient to an Android device within the ISM frequency bands (2.4-2.48 GHz) where the data is displayed and stored in real time. This study is a stepping stone toward more portable heart monitoring that can communicate with the doctor in real time from remote locations.
NASA Astrophysics Data System (ADS)
Fatland, D. R.; Anandakrishnan, S.; Heavner, M.
2004-12-01
We describe tough, cheap, reliable field computers configured as wireless networks for distributed high-volume data acquisition and low-cost data recovery. Running under the GNU/Linux open source model these network nodes ('Bricks') are intended for either autonomous or managed deployment for many months in harsh Arctic conditions. We present here results from Generation-1 Bricks used in 2004 for glacier seismology research in Alaska and Antarctica and describe future generation Bricks in terms of core capabilities and a growing list of field applications. Subsequent generations of Bricks will feature low-power embedded architecture, large data storage capacity (GB), long range telemetry (15 km+ up from 3 km currently), and robust operational software. The list of Brick applications is growing to include Geodetic GPS, Bioacoustics (bats to whales), volcano seismicity, tracking marine fauna, ice sounding via distributed microwave receivers and more. This NASA-supported STTR project capitalizes on advancing computer/wireless technology to get scientists more data per research budget dollar, solving system integration problems and thereby getting researchers out of the hardware lab and into the field. One exemplary scenario: An investigator can install a Brick network in a remote polar environment to collect data for several months and then fly over the site to recover the data via wireless telemetry. In the past year Brick networks have moved beyond proof-of-concept to the full-bore development and testing stage; they will be a mature and powerful tool available for IPY 2007-8.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1125 RF safety. Portable devices as defined in § 2.1093(b) of this chapter operating in the WMTS are subject to radio frequency...
47 CFR 95.1123 - Protection of medical equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 47 Telecommunication 5 2012-10-01 2012-10-01 false Protection of medical equipment. 95.1123... SERVICES PERSONAL RADIO SERVICES Wireless Medical Telemetry Service (WMTS) General Provisions § 95.1123 Protection of medical equipment. The manufacturers, installers and users of WMTS equipment are cautioned that...
Schwensen, J F; Menné Bonefeld, C; Zachariae, C; Agerbeck, C; Petersen, T H; Geisler, C; Bollmann, U E; Bester, K; Johansen, J D
2017-01-01
In the light of the exceptionally high rates of contact allergy to the preservative methylisothiazolinone (MI), information about cross-reactivity between MI, octylisothiazolinone (OIT) and benzisothiazolinone (BIT) is needed. To study cross-reactivity between MI and OIT, and between MI and BIT. Immune responses to MI, OIT and BIT were studied in vehicle and MI-sensitized female CBA mice by a modified local lymph node assay. The inflammatory response was measured by ear thickness, cell proliferation of CD4 + and CD8 + T cells, and CD19 + B cells in the auricular draining lymph nodes. MI induced significant, strong, concentration-dependent immune responses in the draining lymph nodes following a sensitization phase of three consecutive days. Groups of MI-sensitized mice were challenged on day 23 with 0·4% MI, 0·7% OIT and 1·9% BIT - concentrations corresponding to their individual EC3 values. No statistically significant difference in proliferation of CD4 + and CD8 + T cells was observed between mice challenged with MI compared with mice challenged with BIT and OIT. The data indicate cross-reactivity between MI, OIT and BIT, when the potency of the chemical was taken into account in choice of challenge concentration. This means that MI-sensitized individuals may react to OIT and BIT if exposed to sufficient concentrations. © 2016 British Association of Dermatologists.
Gardner, Alan T.; Karam, Hanan N.; Mulligan, Ann E.; Harvey, Charles F.; Hammar, Terence R.; Hemond, Harold F.
2009-01-01
An instrument has been built to carry out continuous in-situ measurement of small differences in water pressure, conductivity and temperature, in natural surface water and groundwater systems. A low-cost data telemetry system provides data on shore in real time if desired. The immediate purpose of measurements by this device is to continuously infer fluxes of water across the sediment-water interface in a complex estuarine system; however, direct application to assessment of sediment-water fluxes in rivers, lakes, and other systems is also possible. Key objectives of the design include both low cost, and accuracy of the order of ±0.5 mm H2O in measured head difference between the instrument's two pressure ports. These objectives have been met, although a revision to the design of one component was found to be necessary. Deployments of up to nine months, and wireless range in excess of 300 m have been demonstrated. PMID:22389608
PIC microcontroller-based RF wireless ECG monitoring system.
Oweis, R J; Barhoum, A
2007-01-01
This paper presents a radio-telemetry system that provides the possibility of ECG signal transmission from a patient detection circuit via an RF data link. A PC then receives the signal through the National Instrument data acquisition card (NIDAQ). The PC is equipped with software allowing the received ECG signals to be saved, analysed, and sent by email to another part of the world. The proposed telemetry system consists of a patient unit and a PC unit. The amplified and filtered ECG signal is sampled 360 times per second, and the A/D conversion is performed by a PIC16f877 microcontroller. The major contribution of the final proposed system is that it detects, processes and sends patients ECG data over a wireless RF link to a maximum distance of 200 m. Transmitted ECG data with different numbers of samples were received, decoded by means of another PIC microcontroller, and displayed using MATLAB program. The designed software is presented in a graphical user interface utility.
Control of Fan Blade Vibrations Using Piezoelectrics and Bi-Directional Telemetry
NASA Technical Reports Server (NTRS)
Provenza, Andrew J.; Morrison, Carlos R.
2011-01-01
A novel wireless device which transfers supply power through induction to rotating operational amplifiers and transmits low voltage AC signals to and from a rotating body by way of radio telemetry has been successfully demonstrated in the NASA Glenn Research Center (GRC) Dynamic Spin Test Facility. In the demonstration described herein, a rotating operational amplifier provides controllable AC power to a piezoelectric patch epoxied to the surface of a rotating Ti plate. The amplitude and phase of the sinusoidal voltage command signal, transmitted wirelessly to the amplifier, was tuned to completely suppress the 3rd bending resonant vibration of the plate. The plate's 3rd bending resonance was excited using rotating magnetic bearing excitation while it spun at slow speed in a vacuum chamber. A second patch on the opposite side of the plate was used as a sensor. This paper discusses the characteristics of this novel device, the details of a spin test, results from a preliminary demonstration, and future plans.
A Silicon Carbide Wireless Temperature Sensing System for High Temperature Applications
Yang, Jie
2013-01-01
In this article, an extreme environment-capable temperature sensing system based on state-of-art silicon carbide (SiC) wireless electronics is presented. In conjunction with a Pt-Pb thermocouple, the SiC wireless sensor suite is operable at 450 °C while under centrifugal load greater than 1,000 g. This SiC wireless temperature sensing system is designed to be non-intrusively embedded inside the gas turbine generators, acquiring the temperature information of critical components such as turbine blades, and wirelessly transmitting the information to the receiver located outside the turbine engine. A prototype system was developed and verified up to 450 °C through high temperature lab testing. The combination of the extreme temperature SiC wireless telemetry technology and integrated harsh environment sensors will allow for condition-based in-situ maintenance of power generators and aircraft turbines in field operation, and can be applied in many other industries requiring extreme environment monitoring and maintenance. PMID:23377189
Low-power wireless micromanometer system for acute and chronic bladder-pressure monitoring.
Majerus, Steve J A; Fletter, Paul C; Damaser, Margot S; Garverick, Steven L
2011-03-01
This letter describes the design, fabrication, and testing of a wireless bladder-pressure-sensing system for chronic, point-of-care applications, such as urodynamics or closed-loop neuromodulation. The system consists of a miniature implantable device and an external RF receiver and wireless battery charger. The implant is small enough to be cystoscopically implanted within the bladder wall, where it is securely held and shielded from the urine stream. The implant consists of a custom application-specific integrated circuit (ASIC), a pressure transducer, a rechargeable battery, and wireless telemetry and recharging antennas. The ASIC includes instrumentation, wireless transmission, and power-management circuitry, and on an average draws less than 9 μA from the 3.6-V battery. The battery charge can be wirelessly replenished with daily 6-h recharge periods that can occur during the periods of sleep. Acute in vivo evaluation of the pressure-sensing system in canine models has demonstrated that the system can accurately capture lumen pressure from a submucosal implant location.
Sustained unresponsiveness to peanut in subjects who have completed peanut oral immunotherapy
Vickery, Brian P.; Scurlock, Amy M.; Kulis, Michael; Steele, Pamela H.; Kamilaris, Janet; Berglund, Jelena P.; Burk, Caitlin; Hiegel, Anne; Carlisle, Suzanna; Christie, Lynn; Perry, Tamara T.; Pesek, Robbie D.; Sheikh, Saira; Virkud, Yamini; Smith, P. Brian; Shamji, Mohamed H.; Durham, Stephen R.; Jones, Stacie M.; Burks, A. Wesley
2013-01-01
Background Although peanut oral immunotherapy (OIT) has been conclusively shown to cause desensitization, it is currently unknown whether clinical protection persists after stopping therapy. Objective Our primary objective was to determine whether peanut OIT can induce sustained unresponsiveness following withdrawal of OIT. Methods We conducted a pilot clinical trial of peanut OIT at two U.S. centers. Subjects aged 1–16 were recruited and treated for up to five years with peanut OIT. The protocol was modified over time to permit dose increases to a maximum of 4000 mg peanut protein/day. Blood was collected at multiple time points. Clinical endpoints were measured with 5000 mg double-blinded, placebo-controlled food challenges once specific criteria were met. Results Of the 39 subjects originally enrolled, 24 completed the protocol and had evaluable outcomes. 12/24 (50%) successfully passed a challenge one month after stopping OIT and achieved sustained unresponsiveness. Peanut was added to the diet. At baseline and the time of challenge, such subjects had smaller skin tests as well as lower IgE levels specific for peanut, Ara h 1, and Ara h 2, and lower ratios of peanut-specific:total IgE, compared to subjects not passing. There were no differences in peanut IgG4 levels or functional activity at end-of-study. Conclusions This is the first demonstration of sustained unresponsiveness after peanut OIT, occurring in half of subjects treated up to five years. OIT favorably modified the peanut-specific immune response in all subjects completing the protocol. Smaller skin tests and lower allergen-specific IgE levels were predictive of successful outcome. PMID:24361082
Implantable physiologic controller for left ventricular assist devices with telemetry capability.
Asgari, Siavash S; Bonde, Pramod
2014-01-01
Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Is oral immunotherapy the cure for food allergies?
Nowak-Wegrzyn, Anna; Fiocchi, Alessandro
2010-06-01
To review current evidence on food oral immunotherapy (OIT). Desensitized state, defined as the ingestion of a substantial amount of food in the home diet that protects from severe reactions to accidental exposures, can be achieved by approximately 50-75% of the children treated with OIT. The rate of permanent tolerance is unknown; the longer duration of OIT may result in permanent tolerance. Side effects are common both during the initial dose escalation and during home dosing. Most reactions are mild (oral pruritus, abdominal discomfort, and rashes) and decrease in frequency with the longer duration of OIT. Severe reactions treated with epinephrine have been reported during home dosing. Factors associated with increased risk of reactions to previously tolerated doses during home dosing include exercise, viral infection, dosing on empty stomach, menses, and asthma exacerbation. These preliminary data on OIT are encouraging. Additional studies must answer multiple questions including optimal dose, ideal duration of oral/sublingual immunotherapy, degree of protection, efficacy for different ages, severity and type of food allergy responsive to treatment and need for patient protection during home administration. Until these questions are answered in rigorous multicenter randomized and placebo-controlled trials, OIT remains an experimental approach with not sufficiently well established risk-to-benefit ratio.
Maeta, Akihiro; Sakamoto, Yoko; Yuki, Sayo; Takahashi, Kyoko
2017-01-01
We propose a new oral immunotherapy (OIT) method that includes a small amount of a food allergen in the diet. However, it is not clear whether this method will induce oral desensitization and immune tolerance. Therefore, we investigated the therapeutic effectiveness using a 1% food allergen diet in an allergic mouse model. C3H/HeJ mice were sensitized to ovomucoid (OM) in alum four times at 12-d intervals. Sensitized mice were divided into two groups: the OIT group (19% casein diet with 1% OM) and the non-treated group (20% casein diet without OM). The non-sensitized mice served as the non-allergy group. The OIT treatment was performed for 4 wk. To assess desensitization and immune tolerance, we performed oral and intraperitoneal OM challenges, assessed vascular permeability of the dorsal skin, and measured allergic biomarkers. The OIT group exhibited significantly lower oral symptom scores and vascular permeability than the non-treated group, but the two groups did not differ in intraperitoneal allergy symptom scores. Furthermore, the OIT group had significantly higher OM-specific IgA levels in their plasma than the non-treated group. However, the plasma levels of OM-specific IgE, IgG1, and IgG2a were not significantly different between the OIT and the non-treated groups. These results suggest that the proposed OIT using an OM-supplemented diet may induce desensitization, but not immune tolerance, in an OM allergic mouse model.
[Does fertility treatment increase the risk of breast cancer? Current knowledge and meta-analysis].
Gabriele, V; Benabu, J-C; Ohl, J; Youssef, C Akladios; Mathelin, C
2017-05-01
The objective of this review was to assess the level of risk of breast cancer for women exposed to ovulation-inducing therapy (OIT). The 25 selected studies were extracted from the PUBMED database from January 2000 until March 2016 with the following key-words: "fertility agents", "infertility treatments", "clomiphene citrate", "buserelin", "ovarian stimulation", "assisted reproductive technology" and "breast cancer". Our meta-analysis was performed using Review Manager software, Cochrane Collaboration, 2014. The results were calculated by type of OIT, as well as globally. The analysis of these published epidemiological studies confirms that exposition to OIT is not a breast cancer risk factor, but the results are contradictory. Two studies have shown a significantly increased risk of breast cancer in a population of infertile women, while two others have found a significant decrease of this risk. The twenty others did not show any impact of IOT over this risk. Our meta-analysis of 20 selected studies has not identified a significant association between exposition to OIT and breast cancer risk (relative risk=0,96; IC 95: (0,81-1,14) for cohort studies and odds ratio=0,94; IC 95% (0,81-1,10) for case-control studies). Exposition to OIT is not an identified risk factor for breast cancer. A message reassuring about a possible risk of OIT-related breast cancer should be given to these women. Exposition to OIT is therefore not an indication of increased breast surveillance. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Astaras, Alexander; Arvanitidou, Marina; Chouvarda, Ioanna; Kilintzis, Vassilis; Koutkias, Vassilis; Sanchez, Eduardo Monton; Stalidis, George; Triantafyllidis, Andreas; Maglaveras, Nicos
2008-01-01
A flexible, scaleable and cost-effective medical telemetry system is described for monitoring sleep-related disorders in the home environment. The system was designed and built for real-time data acquisition and processing, allowing for additional use in intensive care unit scenarios where rapid medical response is required in case of emergency. It comprises a wearable body area network of Zigbee-compatible wireless sensors worn by the subject, a central database repository residing in the medical centre and thin client workstations located at the subject's home and in the clinician's office. The system supports heterogeneous setup configurations, involving a variety of data acquisition sensors to suit several medical applications. All telemetry data is securely transferred and stored in the central database under the clinicians' ownership and control.
An inductive narrow-pulse RFID telemetry system for gastric slow waves monitoring.
Javan-Khoskholgh, Amir; Abukhalaf, Zaid; Ji Li; Miller, Larry S; Kiani, Mehdi; Farajidavar, Aydin
2016-08-01
We present a passive data telemetry system for real-time monitoring of gastric electrical activity of a living subject. The system is composed of three subsystems: an implantable unit (IU), a wearable unit (WU), and a stationary unit (SU). Data communication between the IU and WU is based on a radio-frequency identification (RFID) link operating at 13.56 MHz. Since wireless power transmission and reverse data telemetry system share the same inductive interface, a load shift keying (LSK)-based differential pulse position (DPP) coding data communication with only 6.25% duty cycle is developed to guarantee consistent wireless downlink power transmission and uplink high data transfer rate, simultaneously. The clock and data are encoded into one signal by an MSP430 microcontroller (MCU) at the IU side. This signal is sent to the WU through the inductive link, where decoded by an MSP432 MCU. Finally, the retrieved data at the WU are transmitted to the SU connected to a PC via a 2.4 GHz transceiver for real-time display and analysis. The results of the measurements on the implemented test bench, demonstrate IU-WU 125 kb/s and WU-SU 2 Mb/s data transmission rate with no observed mismatch, while the data stream was randomly generated, and matching between the transmitted data by the IU and received by the SU verified by a custom-made automated software.
PREDICTIVE MEASURES OF A RESIDENT'S PERFORMANCE ON WRITTEN ORTHOPAEDIC BOARD SCORES
Dyrstad, Bradley W; Pope, David; Milbrandt, Joseph C; Beck, Ryan T; Weinhoeft, Anita L.; Idusuyi, Osaretin B
2011-01-01
Objective Residency programs are continually attempting to predict the performance of both current and potential residents. Previous studies have supported the use of USMLE Steps 1 and 2 as predictors of Orthopaedic In-Training Examination (OITE) and eventual American Board of Orthopaedic Surgery success, while others show no significant correlation. A strong performance on OITE examinations does correlate with strong residency performance, and some believe OITE scores are good predictors of future written board success. The current study was designed to examine potential differences in resident assessment measures and their predictive value for written boards. Design/Methods A retrospective review of resident performance data was performed for the past 10 years. Personalized information was removed by the residency coordinator. USMLE Step 1, USMLE Step 2, Orthopaedic In-Training Examination (from first to fifth years of training), and written orthopaedic specialty board scores were collected. Subsequently, the residents were separated into two groups, those scoring above the 35th percentile on written boards and those scoring below. Data were analyzed using correlation and regression analyses to compare and contrast the scores across all tests. Results A significant difference was seen between the groups in regard to USMLE scores for both Step 1 and 2. Also, a significant difference was found between OITE scores for both the second and fifth years. Positive correlations were found for USMLE Step 1, Step 2, OITE 2 and OITE 5 when compared to performance on written boards. One resident initially failed written boards, but passed on the second attempt This resident consistently scored in the 20th and 30th percentiles on the in-training examinations. Conclusions USMLE Step 1 and 2 scores along with OITE scores are helpful in gauging an orthopaedic resident’s performance on written boards. Lower USMLE scores along with consistently low OITE scores likely identify residents at risk of failing their written boards. Close monitoring of the annual OITE scores is recommended and may be useful to identify struggling residents. Future work involving multiple institutions is warranted and would ensure applicability of our findings to other orthopedic residency programs. PMID:22096449
LEAK DETECTION AND WIRELESS TELEMETRY FOR WATER DISTRIBUTION AND SEWERAGE SYSTEMS - PHASE I
According to the study EPA 2000 Community Water System Survey Data on Pipe Assets, the infrastructure for water distribution and sewerage systems is aging and requires replacement. In addition, in EPA’s September 2002 report Clean Water and Drinking Water Infr...
Martin, Adam S; McMains, M Craig; Shacklett, Andrew G; Awan, Hisham M
2018-06-01
To provide an updated analysis of the hand surgery section of the Orthopaedic In-Training Examination (OITE) from 2009 to 2015. The goal was to contribute to the existing literature on the analysis of OITE questions, to aid both residents and residency programs in preparation for the OITE and board examination. The authors analyzed all OITE questions pertaining to hand surgery between 2009 and 2015. Hand questions were analyzed for category and subcategory of content, cited reference, treatment intervention, and imaging modality used. Hand-related questions comprised 157 of the 1,872 OITE questions (8.4%). Nine general topic areas were identified, the most common of which were fracture-dislocation, tendon/ligament, nerve, congenital, and amputation. Trends existed in the recommended references; the 5 journals and 2 textbooks that were consistently cited included the Journal of Hand Surgery (American Volume), the Journal of the American Academy of Orthopaedic Surgeons, the Journal of Bone and Joint Surgery (American Volume), the Journal of Hand Surgery (European Volume), Hand Clinics, Orthopaedic Knowledge Update, and Green's Operative Hand Surgery, respectively. Knowledge regarding topics and resources used for OITE hand questions could be mutually beneficial to both residents and residency programs. This information would consolidate resident OITE and board examination study time. Furthermore, this analysis could help residency programs develop or improve educational conferences and journal clubs. An understanding of question content and sources should enable efficient learning and improved scores on this section of the examination. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Maeta, Akihiro; Matsushima, Marin; Katahira, Risako; Sakamoto, Natsumi; Takahashi, Kyoko
2018-05-30
The objective of this study was to determine the required concentration of egg white (EW) in the diet to induce oral desensitization and/or immune tolerance within 4 weeks of oral immunotherapy (OIT) in an EW allergic mouse model. Female BALB/c mice were systemically sensitized to EW by intraperitoneal injections and subsequently subjected to oral allergen gavage. Sensitized mice were provided 4 weeks of OIT by supplementing with 0 (non-OIT), 0.01, 0.1, or 1% EW in a 20% casein diet. Nonsensitized mice served as the nonallergy group. We performed oral and intraperitoneal EW challenges, assessed vascular permeability in the dorsal skin, and measured allergic biomarkers. The change in rectal temperature after oral challenge was not significantly different between the nonallergy and 1% EW groups, and the frequency of diarrhea in the 1% EW group was lower than that in the non-OIT group. The levels of plasma ovomucoid-specific IgE, IgA, and IgG2a in the 1% EW group at the study endpoint were significantly lower than those in the non-OIT group. IFN-γ and IL-10 secretions of spleen lymphocytes in the 1% EW group were significantly higher than those in the non-OIT group, and the percentage of CD4+Foxp3+ cells in the 1% EW group was higher than that in the non-OIT group. These results suggested that diet supplemented with 1% EW can induce oral desensitization and immune tolerance in the EW allergic mouse model. © 2018 S. Karger AG, Basel.
Sheybani, Roya; Cobo, Angelica; Meng, Ellis
2015-08-01
We present a fully integrated implantable electrolysis-based micropump with incorporated EI dosing sensors. Wireless powering and data telemetry (through amplitude and frequency modulation) were utilized to achieve variable flow control and a bi-directional data link with the sensors. Wireless infusion rate control (0.14-1.04 μL/min) and dose sensing (bolus resolution of 0.55-2 μL) were each calibrated separately with the final circuit architecture and then simultaneous wireless flow control and dose sensing were demonstrated. Recombination detection using the dosing system, as well as, effects of coil separation distance and misalignment in wireless power and data transfer were studied. A custom-made normally closed spring-loaded ball check valve was designed and incorporated at the reservoir outlet to prevent backflow of fluids as a result of the reverse pressure gradient caused by recombination of electrolysis gases. Successful delivery, infusion rate control, and dose sensing were achieved in simulated brain tissue.
OIT Times Newsletter: Volume 3, Number 1, Winter 2000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sousa, L.
The Winter 2000 edition of the OIT Times newsletter, a quarterly publication produced by the Office of Industrial Technologies, highlights the 1999 start-up projects, announces the OIT solicitation schedule for FY2000, and features the success of the Ohio diecasting showcase. One of the quarterly highlights was Secretary Richardson's presentation of a Certificate of Partnership to Malden Mills CEO Aaron Feuerstein at the dedication of the plant's new, advanced cogeneration system.
Yeon, Pyungwoo; Mirbozorgi, S Abdollah; Lim, Jaemyung; Ghovanloo, Maysam
2017-12-01
This paper presents a feasibility study of wireless power and data transmission through an inductive link to a 1-mm 2 implant, to be used as a free-floating neural probe, distributed across a brain area of interest. The proposed structure utilizes a four-coil inductive link for back telemetry, shared with a three-coil link for wireless power transmission. We propose a design procedure for geometrical optimization of the inductive link in terms of power transmission efficiency (PTE) considering specific absorption rate and data rate. We have designed a low-power pulse-based active data transmission circuit and characterized performance of the proposed inductive link in terms of its data rate and bit error rate (BER). The 1-mm 2 data-Tx/power-Rx coil is implemented using insulated bonding wire with diameter, resulting in measured PTE in tissue media of 2.01% at 131 MHz and 1.8-cm coil separation distance when the resonator coil inner radius is 1 cm. The measured BER at 1-Mbps data rate was and in the air and tissue environments, respectively.
Franklin, Corinna C; Bosch, Patrick P; Grudziak, Jan S; Dede, Ozgur; Ramirez, Rey N; Mendelson, Steven A; Ward, W Timothy; Brooks, Maria; Kenkre, Tanya; Lubahn, John D; Deeney, Vincent F; Roach, James W
2017-03-01
Performance on the Orthopaedic In-training Examination (OITE) has been correlated with performance on the written portion of the American Board of Orthopaedic Surgery examination. Herein we sought to discover whether adding a regular pediatric didactic lecture improved residents' performance on the OITE's pediatric domain. In 2012, a didactic lecture series was started in the University of Pittsburgh Medical Center (UPMC) Hamot Orthopaedic Residency Program (Hamot). This includes all topics in pediatric orthopaedic surgery and has teaching faculty present, and occurs weekly with all residents attending. A neighboring program [UMPC Pittsburgh (Pitt)] shares in these conferences, but only during their pediatric rotation. We sought to determine the effectiveness of the conference by comparing the historic scores from each program on the pediatric domain of the OITE examination to scores after the institution of the conference, and by comparing the 2 programs' scores. Both programs demonstrated improvement in OITE scores. In 2008, the mean examination score was 19.6±4.3 (11.0 to 30.0), and the mean percentile was 57.7±12.6 (32.0 to 88.0); in 2014, the mean examination score was 23.5±4.2 (14.0 to 33.0) and the mean percentile was 67.1±12.1 (40.0 to 94.0). OITE scores and percentiles improved with post graduate year (P<0.0001). Compared with the preconference years, Hamot residents answered 3.99 more questions correctly (P<0.0001) and Pitt residents answered 2.93 more questions correctly (P<0.0001). Before the conference, site was not a predictor of OITE score (P=0.06) or percentile (P=0.08); there was no significant difference found between the mean scores per program. However, in the postconference years, site did predict OITE scores. Controlling for year in training, Hamot residents scored higher on the OITE (2.3 points higher, P=0.003) and had higher percentiles (0.07 higher, P=0.004) than Pitt residents during the postconference years. This study suggests that adding a didactic pediatric lecture improved residents' scores on the OITE and indirectly suggests that more frequent attendance is associated with better scores. Level III-retrospective case-control study.
Wireless monitoring of the biological object state at microwave frequencies: A review
NASA Astrophysics Data System (ADS)
Vendik, I. B.; Vendik, O. G.; Kozlov, D. S.; Munina, I. V.; Pleskachev, V. V.; Rusakov, A. S.; Tural'chuk, P. A.
2016-01-01
Radio-frequency identification systems used for the remote diagnostics of diseases and contactless monitoring and assessment of human health are reviewed. The propagation of electromagnetic waves inside a biological medium and along interfaces between different media, as well as the problem of telemetry data acquisition from implanted systems or system on the human body surface using wireless sensors, is considered. Emphasis is on radio-frequency identification systems that use far-field electromagnetic radiation, since they are necessary in emergency situations to find injured people in hard-to-reach places and assess the state of emergency response workers.
The UTCOMS: a wireless video capsule nanoendoscope
NASA Astrophysics Data System (ADS)
Lee, Mike M.; Lee, Eun-Mi; Cho, Byung Lok; Eshraghian, Kamran; Kim, Yun-Hyun
2006-02-01
This research shows a 1mW Low Power and real-time imaging Tx/Rx communication system via RF-delay smart Antenna using up to 10GHz UWB(Ultra WideBand) as a concept of Wireless Medical Telemetry Service (WMTS). This UTCOMS (COMmunication System for Nano-scale USLI designed Endoscope using UWB technology) results in less body loss(about 6~13dB) at high frequency, disposable and ingestible compact size of 5×10 mm2 and multifunction, bidirectional communications, independent subsystem control multichannel, and high sensitivity smart receiving antenna of three-dimensional image captured still and moving images.
Analysis of the basic science section of the orthopaedic in-training examination.
Sheibani-Rad, Shahin; Arnoczky, Steven Paul; Walter, Norman E
2012-08-01
Since 1963, the Orthopaedic In-Training Examination (OITE) has been administered to orthopedic residents to assess residents' knowledge and measure the quality of teaching within individual programs. The OITE currently consists of 275 questions divided among 12 domains. This study analyzed all OITE basic science questions between 2006 and 2010. The following data were recorded: number of questions, question taxonomy, category of question, type of imaging modality, and recommended journal and book references. Between 2006 and 2010, the basic science section constituted 12.2% of the OITE. The assessment of taxonomy classification showed that recall-type questions were the most common, at 81.4%. Imaging modalities typically involved questions on radiographs and constituted 6.2% of the OITE basic science section. The majority of questions were basic science questions (eg, genetics, cell replication, and bone metabolism), with an average of 26.4 questions per year. The Journal of Bone & Joint Surgery (American Volume) and the American Academy of Orthopaedic Surgeons' Orthopaedic Basic Science were the most commonly and consistently cited journal and review book, respectively. This study provides the first review of the question content and recommended references of the OITE basic science section. This information will provide orthopedic trainees, orthopedic residency programs, and the American Academy of Orthopaedic Surgeons Evaluation Committee valuable information related to improving residents' knowledge and performance and optimizing basic science educational curricula. Copyright 2012, SLACK Incorporated.
Code of Federal Regulations, 2011 CFR
2011-10-01
... frequency range 608-614 MHz and that will be located near the radio astronomy observatories listed below..., and obtain the written concurrence of, the director of the affected radio astronomy observatory before the equipment can be installed or operated (a) Within 80 kilometers of: (1) National Astronomy and...
Code of Federal Regulations, 2014 CFR
2014-10-01
... frequency range 608-614 MHz and that will be located near the radio astronomy observatories listed below..., and obtain the written concurrence of, the director of the affected radio astronomy observatory before the equipment can be installed or operated (a) Within 80 kilometers of: (1) National Astronomy and...
Code of Federal Regulations, 2013 CFR
2013-10-01
... frequency range 608-614 MHz and that will be located near the radio astronomy observatories listed below..., and obtain the written concurrence of, the director of the affected radio astronomy observatory before the equipment can be installed or operated (a) Within 80 kilometers of: (1) National Astronomy and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... frequency range 608-614 MHz and that will be located near the radio astronomy observatories listed below..., and obtain the written concurrence of, the director of the affected radio astronomy observatory before the equipment can be installed or operated (a) Within 80 kilometers of: (1) National Astronomy and...
Code of Federal Regulations, 2012 CFR
2012-10-01
... frequency range 608-614 MHz and that will be located near the radio astronomy observatories listed below..., and obtain the written concurrence of, the director of the affected radio astronomy observatory before the equipment can be installed or operated (a) Within 80 kilometers of: (1) National Astronomy and...
ERIC Educational Resources Information Center
Fields, Thomas A.; Ashmore, Lear L.
1980-01-01
Expressive language samples were obtained from 20 children in four location-stimulus combinations and from wireless radio telemetry. No significant differences existed between the locations of home and clinic, but significant differences were noted among samples elicited using pictures as opposed to open-ended questions as compared to telemetry…
Xu, Wencheng; Shekhar, Sameer; Abbaspour-Tamijani, Abbas; Towe, Bruce C.; Miranda, Félix A.; Chae, Junseok
2011-01-01
The ability to safely monitor neuropotentials is essential in establishing methods to study the brain. Current research focuses on the wireless telemetry aspect of implantable sensors in order to make these devices ubiquitous and safe. Chronic implants necessitate superior reliability and durability of the integrated electronics. The power consumption of implanted electronics must also be limited to within several milliwatts to microwatts to minimize heat trauma in the human body. In order to address these severe requirements, we developed an entirely passive and wireless microsystem for recording neuropotentials. An external interrogator supplies a fundamental microwave carrier to the microsystem. The microsystem comprises varactors that perform nonlinear mixing of neuropotential and fundamental carrier signals. The varactors generate third-order mixing products that are wirelessly backscattered to the external interrogator where the original neuropotential signals are recovered. Performance of the neuro-recording microsystem was demonstrated by wireless recording of emulated and in vivo neuropotentials. The obtained results were wireless recovery of neuropotentials as low as approximately 500 microvolts peak-to-peak (μVpp) with a bandwidth of 10 Hz to 3 kHz (for emulated signals) and with 128 epoch signal averaging of repetitive signals (for in vivo signals). PMID:22267898
High-Rate Wireless Airborne Network Demonstration (HiWAND) Flight Test Results
NASA Technical Reports Server (NTRS)
Franz, Russell
2008-01-01
An increasing number of flight research and airborne science experiments now contain network-ready systems that could benefit from a high-rate bidirectional air-to-ground network link. A prototype system, the High-Rate Wireless Airborne Network Demonstration, was developed from commercial off-the-shelf components while leveraging the existing telemetry infrastructure on the Western Aeronautical Test Range. This approach resulted in a cost-effective, long-range, line-of-sight network link over the S and the L frequency bands using both frequency modulation and shaped-offset quadrature phase-shift keying modulation. This report discusses system configuration and the flight test results.
High-Rate Wireless Airborne Network Demonstration (HiWAND) Flight Test Results
NASA Technical Reports Server (NTRS)
Franz, Russell
2007-01-01
An increasing number of flight research and airborne science experiments now contain network-ready systems that could benefit from a high-rate bidirectional air-to-ground network link. A prototype system, the High-Rate Wireless Airborne Network Demonstration, was developed from commercial off-the-shelf components while leveraging the existing telemetry infrastructure on the Western Aeronautical Test Range. This approach resulted in a cost-effective, long-range, line-of-sight network link over the S and the L frequency bands using both frequency modulation and shaped-offset quadrature phase-shift keying modulation. This paper discusses system configuration and the flight test results.
A Wireless FSCV Monitoring IC With Analog Background Subtraction and UWB Telemetry.
Dorta-Quiñones, Carlos I; Wang, Xiao Y; Dokania, Rajeev K; Gailey, Alycia; Lindau, Manfred; Apsel, Alyssa B
2016-04-01
A 30-μW wireless fast-scan cyclic voltammetry monitoring integrated circuit for ultra-wideband (UWB) transmission of dopamine release events in freely-behaving small animals is presented. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus standard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission for low data rates. The 1.5- mm(2) chip, which was fabricated in 65-nm CMOS technology, consists of a low-noise potentiostat frontend, a two-step analog-to-digital converter (ADC), and an impulse-radio UWB transmitter (TX). The duty-cycled frontend and ADC/UWB-TX blocks draw 4 μA and 15 μA from 3-V and 1.2-V supplies, respectively. The chip achieves an input-referred current noise of 92 pA(rms) and an input current range of ±430 nA at a conversion rate of 10 kHz. The packaged device operates from a 3-V coin-cell battery, measures 4.7 × 1.9 cm(2), weighs 4.3 g (including the battery and antenna), and can be carried by small animals. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 1 μM with a carbon-fiber microelectrode (CFM) using 300-V/s FSCV.
A Wireless FSCV Monitoring IC with Analog Background Subtraction and UWB Telemetry
Dorta-Quiñones, Carlos I.; Wang, Xiao Y.; Dokania, Rajeev K.; Gailey, Alycia; Lindau, Manfred; Apsel, Alyssa B.
2015-01-01
A 30-μW wireless fast-scan cyclic voltammetry monitoring integrated circuit for ultra-wideband (UWB) transmission of dopamine release events in freely-behaving small animals is presented. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus standard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission for low data rates. The 1.5-mm2 chip, which was fabricated in 65-nm CMOS technology, consists of a low-noise potentiostat frontend, a two-step analog-to-digital converter (ADC), and an impulse-radio UWB transmitter (TX). The duty-cycled frontend and ADC/UWB-TX blocks draw 4 μA and 15 μA from 3-V and 1.2-V supplies, respectively. The chip achieves an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. The packaged device operates from a 3-V coin-cell battery, measures 4.7 × 1.9 cm2, weighs 4.3 g (including the battery and antenna), and can be carried by small animals. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 1 μM with a carbon-fiber microelectrode (CFM) using 300-V/s FSCV. PMID:26057983
Nachshon, Liat; Goldberg, Michael R; Elizur, Arnon; Levy, Michael B; Schwartz, Naama; Katz, Yitzhak
2015-06-01
Reactions during the home treatment phase of oral immunotherapy (OIT) are not uncommon. An ongoing accurate reporting of home treatment outcomes is crucial for the safety and success of OIT. Previous reports have shown that as few as 20% of patients are truly compliant with paper-based diaries. To develop a Web site-based electronic reporting system (web-RS) for monitoring home treatment during OIT for food allergy. A web-RS was developed and incorporated a thorough questionnaire querying for pertinent data including the dose(s) consumed, occurrence and details of adverse reactions, treatment(s), and relevant potential exacerbating factors. All patients enrolled in milk, peanut, or egg OIT programs for at least 4 weeks from November 2012 through January 2014 were introduced to web-RS (n = 157). Successful reporting through web-RS was defined by consecutive reporting during the first home treatment phase (24 days) after its introduction. Comparisons were made with a previous group of OIT-treated patients (n = 100) who reported by E-mail. Successful reporting was achieved by 142 of 157 patients (90.44%) in contrast to a 75% success rate with E-mail (P = .0009). The odds for successful reporting using web-RS were 3.1 (95% confidence interval 1.6-6.3) times higher compared with using E-mail. Mild reactions were reported more frequently with web-RS (P = .0032). Patient reports were constantly available in real time for medical staff review. No complaints regarding web-RS feasibility were reported. One risk factor for failure to use web-RS was a patient's prior successful OIT experience without using web-RS (P = .012). A web-RS can be a powerful tool for improving OIT safety by achieving a high level of patient cooperation in reporting home treatment results. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Arshak, A; Arshak, K; Waldron, D; Morris, D; Korostynska, O; Jafer, E; Lyons, G
2005-06-01
Telemetry capsules have existed since the 1950s and were used to measure temperature, pH or pressure inside the gastrointestinal (GI) tract. It was hoped that these capsules would replace invasive techniques in the diagnosis of function disorders in the GI tract. However, problems such as signal loss and uncertainty of the pills position limited their use in a clinical setting. In this paper, a review of the capabilities of MicroElectroMechanical Systems (MEMS) and thick film technology (TFT) for the fabrication of a wireless pressure sensing microsystem is presented. The circuit requirements and methods of data transfer are examined. The available fabrication methods for MEMS sensors are also discussed and examples of wireless sensors are given. Finally the limitations of each technology are examined.
On Utilizing Optimal and Information Theoretic Syntactic Modeling for Peptide Classification
NASA Astrophysics Data System (ADS)
Aygün, Eser; Oommen, B. John; Cataltepe, Zehra
Syntactic methods in pattern recognition have been used extensively in bioinformatics, and in particular, in the analysis of gene and protein expressions, and in the recognition and classification of bio-sequences. These methods are almost universally distance-based. This paper concerns the use of an Optimal and Information Theoretic (OIT) probabilistic model [11] to achieve peptide classification using the information residing in their syntactic representations. The latter has traditionally been achieved using the edit distances required in the respective peptide comparisons. We advocate that one can model the differences between compared strings as a mutation model consisting of random Substitutions, Insertions and Deletions (SID) obeying the OIT model. Thus, in this paper, we show that the probability measure obtained from the OIT model can be perceived as a sequence similarity metric, using which a Support Vector Machine (SVM)-based peptide classifier, referred to as OIT_SVM, can be devised.
NASA Technical Reports Server (NTRS)
1978-01-01
In photo above, the electrocardiogram of a hospitalized patient is being transmitted by telemetry. Widely employed in space operations, telemetry is a process wherein instrument data is converted to electrical signals and sent to a receiver where the signals are reconverted to usable information. In this instance, heart readings are picked up by the electrode attached to the patient's body and delivered by wire to the small box shown, which is a telemetry transmitter. The signals are relayed wirelessly to the console in the background, which converts them to EKG data. The data is displayed visually and recorded on a printout; at the same time, it is transmitted to a central control station (upper photo) where a nurse can monitor the condition of several patients simultaneously. The Patient Monitoring System was developed by SCI Systems, Inc., Huntsville, Alabama, in conjunction with Abbott Medical Electronics, Houston, Texas. In developing the system, SCI drew upon its extensive experience as a NASA contractor. The company applied telemetry technology developed for the Saturn launch vehicle and the Apollo spacecraft; instrumentation technology developed for heart, blood pressure and sleep monitoring of astronauts aboard NASA's Skylab long duration space station; and communications technology developed for the Space Shuttle.
Wireless energizing system for an automated implantable sensor.
Swain, Biswaranjan; Nayak, Praveen P; Kar, Durga P; Bhuyan, Satyanarayan; Mishra, Laxmi P
2016-07-01
The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.
Micropower circuits for bidirectional wireless telemetry in neural recording applications.
Neihart, Nathan M; Harrison, Reid R
2005-11-01
State-of-the art neural recording systems require electronics allowing for transcutaneous, bidirectional data transfer. As these circuits will be implanted near the brain, they must be small and low power. We have developed micropower integrated circuits for recovering clock and data signals over a transcutaneous power link. The data recovery circuit produces a digital data signal from an ac power waveform that has been amplitude modulated. We have also developed an FM transmitter with the lowest power dissipation reported for biosignal telemetry. The FM transmitter consists of a low-noise biopotential amplifier and a voltage controlled oscillator used to transmit amplified neural signals at a frequency near 433 MHz. All circuits were fabricated in a standard 0.5-microm CMOS VLSI process. The resulting chip is powered through a wireless inductive link. The power consumption of the clock and data recovery circuits is measured to be 129 microW; the power consumption of the transmitter is measured to be 465 microW when using an external surface mount inductor. Using a parasitic antenna less than 2 mm long, a received power level was measured to be -59.73 dBm at a distance of one meter.
The safety and efficacy of sublingual and oral immunotherapy for milk allergy.
Keet, Corinne A; Frischmeyer-Guerrerio, Pamela A; Thyagarajan, Ananth; Schroeder, John T; Hamilton, Robert G; Boden, Stephen; Steele, Pamela; Driggers, Sarah; Burks, A Wesley; Wood, Robert A
2012-02-01
Oral immunotherapy (OIT) and sublingual immunotherapy (SLIT) are potential therapies for food allergy, but the optimal method of administration, mechanism of action, and duration of response remain unknown. We sought to explore the safety and efficacy of OIT and SLIT for the treatment of cow's milk (CM) allergy. We randomized children with CM allergy to SLIT alone or SLIT followed by OIT. After screening double-blind, placebo-controlled food challenges and initial SLIT escalation, subjects either continued SLIT escalation to 7 mg daily or began OIT to either 1000 mg (the OITB group) or 2000 mg (the OITA group) of milk protein. They were challenged with 8 g of milk protein after 12 and 60 weeks of maintenance. If they passed the 60-week challenge, therapy was withdrawn, with challenges repeated 1 and 6 weeks later. Mechanistic correlates included end point titration skin prick testing and measurement of CM-specific IgE and IgG(4) levels, basophil histamine release, constitutive CD63 expression, CD203c expression, and intracellular spleen tyrosine kinase levels. Thirty subjects with CM allergy aged 6 to 17 years were enrolled. After therapy, 1 of 10 subjects in the SLIT group, 6 of 10 subjects in the SLIT/OITB group, and 8 of 10 subjects in the OITA group passed the 8-g challenge (P = .002, SLIT vs OIT). After avoidance, 6 of 15 subjects (3 of 6 subjects in the OITB group and 3 of 8 subjects in the OITA group) regained reactivity, 2 after only 1 week. Although the overall reaction rate was similar, systemic reactions were more common during OIT than during SLIT. By the end of therapy, titrated CM skin prick test results and CD63 and CD203c expression decreased and CM-specific IgG(4) levels increased in all groups, whereas CM-specific IgE and spontaneous histamine release values decreased in only the OIT group. OIT was more efficacious for desensitization to CM than SLIT alone but was accompanied by more systemic side effects. Clinical desensitization was lost in some cases within 1 week off therapy. Copyright © 2011 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
Development of a biosensor telemetry system for monitoring fermentation in craft breweries.
Farina, Donatella; Zinellu, Manuel; Fanari, Mauro; Porcu, Maria Cristina; Scognamillo, Sergio; Puggioni, Giulia Maria Grazia; Rocchitta, Gaia; Serra, Pier Andrea; Pretti, Luca
2017-03-01
The development and applications of biosensors in the food industry has had a rapid grown due to their sensitivity, specificity and simplicity of use with respect to classical analytical methods. In this study, glucose and ethanol amperometric biosensors integrated with a wireless telemetry system were developed and used for the monitoring of top and bottom fermentations in beer wort samples. The collected data were in good agreement with those obtained by reference methods. The simplicity of construction, the low cost and the short time of analysis, combined with easy interpretation of the results, suggest that these devices could be a valuable alternative to conventional methods for monitoring fermentation processes in the food industry. Copyright © 2016 Elsevier Ltd. All rights reserved.
Delay/Disruption Tolerant Networks (DTN): Testing and Demonstration for Lunar Surface Applications
NASA Technical Reports Server (NTRS)
2009-01-01
This slide presentation reviews the testing of the Delay/Disruption Tolerant Network (DTN) designed for use with Lunar Surface applications. This is being done through the DTN experimental Network (DEN), that permit access and testing by other NASA centers, DTN team members and protocol developers. The objective of this work is to demonstrate DTN for high return applications in lunar scenarios, provide DEN connectivity with analogs of Constellation elements, emulators, and other resources from DTN Team Members, serve as a wireless communications staging ground for remote analog excursions and enable testing of detailed communication scenarios and evaluation of network performance. Three scenarios for DTN on the Lunar surface are reviewed: Motion imagery, Voice and sensor telemetry, and Navigation telemetry.
Wearable Wireless Telemetry System for Implantable Bio-MEMS Sensors
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Miranda, Felix A.; Wilson, Jeffrey D.; Simons, Renita E.
2006-01-01
In this paper, a telemetry and contact-less powering system consisting of an implantable bio-MEMS sensor with a miniature printed square spiral chip antenna and an external wearable garment with printed loop antenna is investigated. The wearable garment pick-up antenna and the implantable chip antenna are in close proximity to each other and hence couple inductively through their near-fields and behave as the primary and the secondary circuits of a transformer, respectively. The numerical and experimental results are graphically presented, and include the design parameter values as a function of the geometry, the relative RF magnetic near-field intensity as a function of the distance and angle, and the current density on the strip conductors, for the implantable chip antenna.
Martorell, A; Alonso, E; Echeverría, L; Escudero, C; García-Rodríguez, R; Blasco, C; Bone, J; Borja-Segade, J; Bracamonte, T; Claver, A; Corzo, J L; De la Hoz, B; Del Olmo, R; Dominguez, O; Fuentes-Aparicio, V; Guallar, I; Larramona, H; Martín-Muñoz, F; Matheu, V; Michavila, A; Ojeda, I; Ojeda, P; Piquer, M; Poza, P; Reche, M; Rodríguez Del Río, P; Rodríguez, M; Ruano, F; Sánchez-García, S; Terrados, S; Valdesoiro, L; Vazquez-Ortiz, M
Cow's milk and egg are the most frequent causes of food allergy in the first years of life. Treatments such as oral immunotherapy (OIT) have been investigated as an alternative to avoidance diets. No clinical practice guides on the management of OIT with milk and egg are currently available. To develop a clinical guide on OIT based on the available scientific evidence and the opinions of experts. A review was made of studies published in the period between 1984 and June 2016, Doctoral Theses published in Spain, and summaries of communications at congresses (SEAIC, SEICAP, EAACI, AAAAI), with evaluation of the opinion consensus established by a group of experts pertaining to the scientific societies SEICAP and SEAIC. Recommendations have been established regarding the indications, requirements and practical aspects of the different phases of OIT, as well as special protocols for patients at high risk of suffering adverse reactions. A clinical practice guide is presented for the management of OIT with milk and egg, based on the opinion consensus of Spanish experts. Copyright © 2017 SEICAP. Published by Elsevier España, S.L.U. All rights reserved.
Frischmeyer-Guerrerio, Pamela A; Masilamani, Madhan; Gu, Wenjuan; Brittain, Erica; Wood, Robert; Kim, Jennifer; Nadeau, Kari; Jarvinen, Kirsi M; Grishin, Alexander; Lindblad, Robert; Sampson, Hugh A
2017-10-01
In our recent clinical trial, the addition of omalizumab to oral immunotherapy (OIT) for milk allergy improved safety, but no significant clinical benefit was detected. We sought to investigate mechanisms by which omalizumab modulates immunity in the context of OIT and to identify baseline biomarkers that predict subgroups of patients most likely to benefit from omalizumab. Blood was obtained at baseline and multiple time points during a placebo-controlled trial of OIT for milk allergy in which subjects were randomized to receive omalizumab or placebo. Immunologic outcomes included measurement of basophil CD63 expression and histamine release and casein-specific CD4 + regulatory T-cell proliferation. Biomarkers were analyzed in relationship to measurements of safety and efficacy. Milk-induced basophil CD63 expression was transiently reduced in whole blood samples from both omalizumab- and placebo-treated subjects. However, IgE-dependent histamine release increased in washed cell preparations from omalizumab- but not placebo-treated subjects. No increase in regulatory T-cell frequency was evident in either group. Subjects with lower rates of adverse reactions, regardless of arm, experienced better clinical outcomes. Pre-OIT basophil reactivity positively associated with occurrence of symptoms during OIT, whereas the baseline milk IgE/total IgE ratio correlated with the likelihood of achieving sustained unresponsiveness. A combination of baseline basophil and serologic biomarkers defined a subset of patients in which adjunctive therapy with omalizumab was associated with attainment of sustained unresponsiveness and a reduction in adverse reactions. Combining omalizumab therapy with milk OIT led to distinct alterations in basophil reactivity but not T-cell responses. Baseline biomarkers can identify subjects most likely to benefit from adjunctive therapy with omalizumab. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. All rights reserved.
Biomedical Wireless Ambulatory Crew Monitor
NASA Technical Reports Server (NTRS)
Chmiel, Alan; Humphreys, Brad
2009-01-01
A compact, ambulatory biometric data acquisition system has been developed for space and commercial terrestrial use. BioWATCH (Bio medical Wireless and Ambulatory Telemetry for Crew Health) acquires signals from biomedical sensors using acquisition modules attached to a common data and power bus. Several slots allow the user to configure the unit by inserting sensor-specific modules. The data are then sent real-time from the unit over any commercially implemented wireless network including 802.11b/g, WCDMA, 3G. This system has a distributed computing hierarchy and has a common data controller on each sensor module. This allows for the modularity of the device along with the tailored ability to control the cards using a relatively small master processor. The distributed nature of this system affords the modularity, size, and power consumption that betters the current state of the art in medical ambulatory data acquisition. A new company was created to market this technology.
Telemetry Standards, RCC Standard 106-17, Chapter 27, RF Network Access Layer
2017-07-01
27-13 27.5.5 Frame Check Sequence Field........................................................................... 27-13 27.6 Power Transients...to the physical media (i.e., the wireless RF network). On the transmission side, it is responsible for framing IP packets for physical transmission...parameters of a radio shall be stored to maintain communications with RF link management after a power interruption or software-initiated reset
NASA Astrophysics Data System (ADS)
Egert, Amanda; Klotz, James; McLeod, Kyle; Harmon, David
2014-10-01
The objectives of these experiments were to characterize rumen motility patterns of cattle fed once daily using a real-time wireless telemetry system, determine when to measure rumen motility with this system, and determine the effect of ruminal dosing of ergot alkaloids on rumen motility. Ruminally cannulated Holstein steers (n = 8) were fed a basal diet of alfalfa cubes once daily. Rumen motility was measured by monitoring real-time pressure changes within the rumen using wireless telemetry and pressure transducers. Experiment 1 consisted of three 24-h rumen pressure collections beginning immediately after feeding. Data were recorded, stored, and analyzed using iox2 software and the rhythmic analyzer. All motility variables differed (P < 0.01) between hours and thirds (8-h periods) of the day. There were no differences between days for most variables. The variance of the second 8-h period of the day was less than (P < 0.01) the first for area and less than the third for amplitude, frequency, duration, and area (P < 0.05). These data demonstrated that the second 8-h period of the day was the least variable for many measures of motility and would provide the best opportunity for testing differences in motility due to treatments. In Exp. 2, the steers (n = 8) were pair-fed the basal diet of Exp. 1 and dosed with endophyte-free (E-) or endophyte-infected (E+; 0 or 10 μg ergovaline + ergovalinine / kg BW; respectively) tall fescue seed before feeding for 15 d. Rumen motility was measured for 8 h beginning 8 h after feeding for the first 14 d of seed dosing. Blood samples were taken on d 1, 7, and 15, and rumen content samples were taken on d 15. Baseline (P = 0.06) and peak (P = 0.04) pressure were lower for E+ steers. Water intake tended (P = 0.10) to be less for E+ steers the first 8 hour period after feeding. The E+ seed treatment at this dosage under thermoneutral conditions did not significantly affect rumen motility, ruminal fill, or dry matter of rumen contents.
Efficacy of baked milk oral immunotherapy in baked milk-reactive allergic patients.
Goldberg, Michael R; Nachshon, Liat; Appel, Michael Y; Elizur, Arnon; Levy, Michael B; Eisenberg, Eli; Sampson, Hugh A; Katz, Yitzhak
2015-12-01
Patients with IgE-mediated cow's milk allergy who are nonreactive to baked milk (BM) can be desensitized with BM to promote tolerance to unheated milk (UM). We sought to test whether patients who are BM reactive can progress in BM oral immunotherapy (OIT) and become desensitized to UM as well. Fifteen patients (>4 years) who previously failed to complete our milk OIT program were enrolled into the BM OIT protocol. A dose of BM (180 °C for 30 minutes) which was less than the eliciting dose was increased 50% monthly while under medical supervision until the primary outcome dose of 1.3 g/d BM protein was achieved. Basophil reactivity and milk protein-specific IgE binding were analyzed at the first round of BM OIT therapy (T0) and at 12 months of BM treatment. In terms of the primary outcome, only 3 (21%) of 14 patients tolerated the 1.3 g/d BM dose. Although some patients initially progressed in BM OIT, 8 of 11 failed because of IgE-mediated reactions. Three did not complete the program because of non-IgE-mediated factors. An increase in challenge threshold to UM was noted in patients continuing until 12 months (P = .003), including those among whom reactions precluded continuation in the program. Patients (n = 3) who successfully reached maintenance had decreased milk-specific IgE reactivity. Furthermore, the mean difference at T0 between induced HM and UM percentages of CD203c expression was significantly lower in patients who successfully completed BM OIT than in those who did not (-11% vs 4.4%, P = .0002), which is consistent with their decreased clinical reactivity to BM. Although use of hypoallergenic BM in OIT is a promising therapy, care must be taken before its administration in BM-reactive patients because of the risk for anaphylaxis and only limited increase in challenge threshold attained. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Patient quality of life following induction of oral immunotherapy for food allergy.
Epstein Rigbi, Na'ama; Katz, Yitzhak; Goldberg, Michael R; Levy, Michael B; Nachshon, Liat; Elizur, Arnon
2016-05-01
Patient quality of life improves following successful completion of oral immunotherapy (OIT), but the process itself might have undesirable effects. We aimed to evaluate patient quality of life following OIT initial induction. The Hebrew version of the Food Allergy Quality of Life Questionnaire-Parental Form (FAQLQ-PF) was validated and administered to the parents of children following the first week of OIT for food allergy (n = 119). Patient demographics and clinical history as well as the course of initial induction week were reviewed. Pre-OIT severity of food allergy, defined as severity of reactions due to accidental exposure to the allergenic food (anaphylactic reactions, p = 0.017; epinephrine use, p = 0.049; emergency room referrals p = 0.003; and hospital admissions, p = 0.015) and a lower number of tolerated doses during initial induction, reflective of a lower maximal tolerated dose for the different allergens (p = 0.011) were associated with worse total FAQLQ-PF scores. The number of tolerated doses during induction and pre-OIT emergency room referrals remained significantly associated with worse total score of the FAQLQ-PF on multivariate analysis (p = 0.016 and p = 0.005, respectively). The correlation between the number of tolerated doses and quality of life scores was moderate-strong primarily in children aged 6-12 years (Total score, r = -0.41, p = 0.001; Emotional Impact r = -0.42, p = 0.001; Food Anxiety, r = -0.38, p = 0.002; Social and Dietary Limitations, r = -0.33, p = 0.009). Pre-OIT reaction severity affects quality of life in both preschool and school-aged food-allergic children. In contrast, a lower maximal tolerated dose during OIT induction is associated with worse indices of quality of life primarily in children aged 6-12 years. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Applications of modern sensors and wireless technology in effective wound management.
Mehmood, Nasir; Hariz, Alex; Fitridge, Robert; Voelcker, Nicolas H
2014-05-01
The management of chronic wounds has emerged as a major health care challenge during the 21st century consuming, significant portions of health care budgets. Chronic wounds such as diabetic foot ulcers, leg ulcers, and pressure sores have a significant negative impact on the quality of life of affected individuals. Covering wounds with suitable dressings facilitates the healing process and is common practice in wound management plans. However, standard dressings do not provide insights into the status of the wound underneath. Parameters such as moisture, pressure, temperature and pH inside the dressings are indicative of the healing rate, infection, and wound healing phase. But owing to the lack of information available from within the dressings, these are often changed to inspect the wound, disturbing the normal healing process of wounds in addition to causing pain to the patient. Sensors embedded in the dressing would provide clinicians and nurses with important information that would aid in wound care decision making, improve patient comfort, and reduce the frequency of dressing changes. The potential benefits of this enabling technology would be seen in terms of a reduction in hospitalization time and health care cost. Modern sensing technology along with wireless radio frequency communication technology is poised to make significant advances in wound management. This review discusses issues related to the design and implementation of sensor technology and telemetry systems both incorporated in wound dressings to devise an automated wound monitoring technology, and also surveys the literature available on current sensor and wireless telemetry systems. Copyright © 2013 Wiley Periodicals, Inc.
Novel immunotherapy and treatment modality for severe food allergies.
Nagakura, Ken-Ichi; Sato, Sakura; Yanagida, Noriyuki; Ebisawa, Motohiro
2017-06-01
In recent years, many studies on oral immunotherapy (OIT) have been conducted; however, few have focused on severe food allergies. The purpose of this review was to assess the efficacy and safety of oral immunotherapies for patients with severe food allergy. We reviewed multiple immunotherapy reports published within a few years or reports focusing on severe food allergies. We also investigated recent studies on OIT and novel food allergy management. Immunotherapies targeting low-dose antigen exposure and oral food challenges using low-dose target volumes may be safer than conventional OIT. It is necessary to consider which immunotherapy regimen is appropriate based on allergy severity of the patient.
Salmivesi, Susanna; Paassilta, Marita; Huhtala, Heini; Nieminen, Riina; Moilanen, Eeva; Korppi, Matti
2018-02-01
This study evaluated whether 15 allergy, immunology or inflammatory markers predicted the long-term use of cows' milk or milk products seven years after the start of oral immunotherapy (OIT) for cows' milk allergy in children. The following laboratory parameters were measured before the OIT at Tampere University Hospital, Finland, and after the six-month escalation phase: serum total immunoglobulin (Ig) E, milk-specific IgG and IgG4, eosinophil cationic protein, eosinophil-derived neurotoxin, interleukins 4, 5, 6, 10 and 12p70 and serum adipokines adiponectin, adipsin, leptin and resistin. Follow-up data from a seven-year phone questionnaire in 2015 were available for 24 children: 14 successful and 10 unsuccessful milk users. There were no significant differences in any of the 15 markers measured at the start of the study between the subjects who later formed the successful and unsuccessful groups. At the end of the six-month escalation phase of OIT, serum adipsin was higher in the group who were unsuccessful milk users at the seven-year follow-up study. None of the 15 allergy, immunology or inflammatory markers were useful in predicting the outcome of OIT. Preliminary evidence was found that high serum adipsin after the six-month escalation phase of OIT might predict unsuccessful outcome. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.
Ganesh Kumar, Nishant; Benvenuti, Michael A; Drolet, Brian C
2017-10-01
In-service training examinations (ITEs) are used to assess residents across specialties. However, it is not clear how they are integrated with the Accreditation Council for Graduate Medical Education Milestones and competencies. This study explored the distribution of specialty-specific milestones and competencies in ITEs for plastic surgery and orthopaedic surgery. In-service training examinations were publicly available for plastic surgery (PSITE) and orthopaedics (OITE). Questions on the PSITE for 2014-2016 and the OITE for 2013-2015 were mapped to the specialty-specific milestones and the 6 competencies. There was an uneven distribution of milestones and competencies in ITE questions. Nine of the 36 Plastic Surgery Milestones represented 52% (341 of 650) of questions, and 3 were not included in the ITE. Of 41 Orthopaedic Surgery Milestones, 7 represented 51% (201 of 394) of questions, and 5 had no representation on the ITE. Among the competencies, patient care was the most common (PSITE = 62% [403 of 650]; OITE = 59% [233 of 394]), followed by medical knowledge (PSITE = 34% [222 of 650]; OITE = 31% [124 of 394]). Distribution of the remaining competencies differed between the 2 specialties (PSITE = 4% [25 of 650]; OITE = 9% [37 of 394]). The ITEs tested slightly more than half of the milestones for the 2 specialties, and focused predominantly on patient care and medical knowledge competencies.
76 FR 19174 - State Trade and Export Promotion (STEP) Pilot Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-06
... SMALL BUSINESS ADMINISTRATION State Trade and Export Promotion (STEP) Pilot Grant Program AGENCY... No. OIT-STEP-2011-01, Modification 1. SUMMARY: Program announcement No. OIT-STEP-2011-01 has been... to the date of application submission for a STEP grant.] Section IV A. 1, Governor's Letter of...
Wireless energizing system for an automated implantable sensor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swain, Biswaranjan; Nayak, Praveen P.; Kar, Durga P.
The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonantmore » frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.« less
RIPPLE: Scalable Medical Telemetry System for Supporting Combat Rescue
2014-01-09
This reduces the burden of transporting multiple systems. For Ripple, we prototyped a system that combined a pulse oximeter , an electrocardiogram, a...o Nonin OEM III Module or Nonin XPOD Pulse Oximeters o Nonin 8000 series PureLight sensors o Shimmer Sensing ECG Board Identify applicable...equipment, e.g. pulse and respiration rate. Advances in wireless communications and miniaturization of electronics has led to the development and
Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor.
Arakawa, Takahiro; Kuroki, Yusuke; Nitta, Hiroki; Chouhan, Prem; Toma, Koji; Sawada, Shin-Ichi; Takeuchi, Shuhei; Sekita, Toshiaki; Akiyoshi, Kazunari; Minakuchi, Shunsuke; Mitsubayashi, Kohji
2016-10-15
We develop detachable "Cavitas sensors" to apply to the human oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor incorporating Pt and Ag/AgCl electrodes on a mouthguard support with an enzyme membrane is developed and tested. Electrodes are formed on the polyethylene terephthalate glycol (PETG) surface of the mouthguard. The Pt working electrode is coated with a glucose oxidase (GOD) membrane. The biosensor seamlessly is integrated with a glucose sensor and a wireless measurement system. When investigating in-vitro performance, the biosensor exhibits a robust relationship between output current and glucose concentration. In artificial saliva composed of salts and proteins, the glucose sensor is capable of highly sensitive detection over a range of 5-1000µmol/L of glucose, which encompasses the range of glucose concentrations found in human saliva. We demonstrate the ability of the sensor and wireless communication module to monitor saliva glucose in a phantom jaw imitating the structure of the human oral cavity. Stable and long-term real-time monitoring (exceeding 5h) with the telemetry system is achieved. The mouthguard biosensor will be useful as a novel method for real-time non-invasive saliva glucose monitoring for better management of dental patients. Copyright © 2015 Elsevier B.V. All rights reserved.
Faerber, Julia; Cummins, Gerard; Pavuluri, Sumanth Kumar; Record, Paul; Rodriguez, Adrian R Ayastuy; Lay, Holly S; McPhillips, Rachael; Cox, Benjamin F; Connor, Ciaran; Gregson, Rachael; Clutton, Richard Eddie; Khan, Sadeque Reza; Cochran, Sandy; Desmulliez, Marc P Y
2018-02-01
This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10 -3 packet error rate and 10 -5 bit error rate and no temperature increase of the tissue according to IEEE standards.
Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording
Weir, Richard F. ff.; Troyk, Phil R.; DeMichele, Glen A.; Kerns, Douglas A.; Schorsch, Jack F.; Maas, Huub
2011-01-01
We have developed a multichannel electrogmyography sensor system capable of receiving and processing signals from up to 32 implanted myoelectric sensors (IMES). The appeal of implanted sensors for myoelectric control is that electromyography (EMG) signals can be measured at their source providing relatively cross-talk-free signals that can be treated as independent control sites. An external telemetry controller receives telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link provides power and commands to the implanted electrodes. Wireless telemetry of EMG signals from sensors implanted in the residual musculature eliminates the problems associated with percutaneous wires, such as infection, breakage, and marsupialization. Each implantable sensor consists of a custom-designed application-specified integrated circuit that is packaged into a bio-compatible RF BION capsule from the Alfred E. Mann Foundation. Implants are designed for permanent long-term implantation with no servicing requirements. We have a fully operational system. The system has been tested in animals. Implants have been chronically implanted in the legs of three cats and are still completely operational four months after implantation. PMID:19224729
Jones, Stacie M.; Burks, A. Wesley; Keet, Corinne; Vickery, Brian P.; Scurlock, Amy M.; Wood, Robert A.; Liu, Andrew H.; Sicherer, Scott H.; Henning, Alice K.; Lindblad, Robert W.; Dawson, Peter; Berin, Cecilia; Fleischer, David M.; Leung, Donald Y. M.; Plaut, Marshall; Sampson, Hugh A.
2016-01-01
Background We previously reported results of a randomized, placebo-controlled study of egg oral immunotherapy (eOIT), in which 27.5% of subjects achieved sustained unresponsiveness (SU) after 2 years. Here we report results of treatment through 4 years and long-term follow-up. Objective To evaluate the efficacy and safety of eOIT in participants treated up to 4 years. Methods Egg-allergic children (5–18 y/o) received eOIT (n=40) for up to 4 years or placebo (n=15) ≤1 year. The key outcome was the percentage of subjects achieving SU by Year 4. Safety and immunologic assessments were performed, and long-term follow-up questionnaires were administered after study conclusion (LFQ-1) and 1 year later (LFQ-2). Results Of 40 eOIT-treated subjects, 20/40 (50.0%) demonstrated SU by Year 4. For those subjects still dosing during Years 3–4, mild symptoms were present in 12/22 (54.5%) subjects. At the time of LFQ, more eOIT subjects [LFQ-1 23/34 (68%); LFQ-2 21/33 (64%)] were consuming unbaked and baked egg vs. placebos [LFQ-1 2/11(18%), p=0.006; LFQ-2 3/12 (25%), p=0.04]. Of subjects achieving SU, 18/20 (90%) completed the LFQ with 18/18 (100%) reporting consumption of all forms of egg. When compared to subjects not achieving SU, subjects achieving SU had higher IgG4 values (p=0.001) and lower egg skin prick test scores (p=0.0002) over time and a lower median baseline ratio of egg-specific IgE to total IgE (1.1% vs. 2.7%, p=0.04). Conclusions SU following egg OIT is enhanced with longer duration of therapy, and increases the likelihood of tolerating unbaked egg in the diet. PMID:26924470
Vonk, Marlotte M; Wagenaar, Laura; Pieters, Raymond H H; Knippels, Leon M J; Willemsen, Linette E M; Smit, Joost J; van Esch, Betty C A M; Garssen, Johan
2017-01-01
Antigen-specific immunotherapy (AIT) is a promising therapeutic approach for both cow's milk allergy (CMA) and peanut allergy (PNA), but needs optimization in terms of efficacy and safety. Compare oral immunotherapy (OIT) and subcutaneous immunotherapy (SCIT) in murine models for CMA and PNA and determine the dose of allergen needed to effectively modify parameters of allergy. Female C3H/HeOuJ mice were sensitized intragastrically (i.g.) to whey or peanut extract with cholera toxin. Mice were treated orally (5 times/week) or subcutaneously (3 times/week) for three consecutive weeks. Hereafter, the acute allergic skin response, anaphylactic shock symptoms and body temperature were measured upon intradermal (i.d.) and intraperitoneal (i.p.) challenge, and mast cell degranulation was measured upon i.g. challenge. Allergen-specific IgE, IgG1 and IgG2a were measured in serum at different time points. Single cell suspensions derived from lymph organs were stimulated with allergen to induce cytokine production and T cell phenotypes were assessed using flow cytometry. Both OIT and SCIT decreased clinically related signs upon challenge in the CMA and PNA model. Interestingly, a rise in allergen-specific IgE was observed during immunotherapy, hereafter, treated mice were protected against the increase in IgE caused by allergen challenge. Allergen-specific IgG1 and IgG2a increased due to both types of AIT. In the CMA model, SCIT and OIT reduced the percentage of activated Th2 cells and increased the percentage of activated Th1 cells in the spleen. OIT increased the percentage of regulatory T cells (Tregs) and activated Th2 cells in the MLN. Th2 cytokines IL-5, IL-13 and IL-10 were reduced after OIT, but not after SCIT. In the PNA model, no differences were observed in percentages of T cell subsets. SCIT induced Th2 cytokines IL-5 and IL-10, whereas OIT had no effect. We have shown clinical protection against allergic manifestations after OIT and SCIT in a CMA and PNA model. Although similar allergen-specific antibody patterns were observed, differences in T cell and cytokine responses were shown. Whether these findings are related to a different mechanism of AIT in CMA and PNA needs to be elucidated.
Kiani, Mehdi; Ghovanloo, Maysam
2009-01-01
This paper presents a standalone closed loop wireless power transmission system that is built around a commercial off-the-shelf (COTS) radio frequency identification (RFID) transceiver (MLX90121) operating at 13.56 MHz. It can be used for inductively powering implantable biomedical devices in a closed loop fashion. Any changes in the distance and misalignment between transmitter and receiver coils in near-field wireless power transmission can cause a significant change in the received power, which can cause either malfunction or excessive heat dissipation. RFID transceivers are often used open loop. However, their back telemetry capability can be utilized to stabilize the received voltage on the implant. Our measurements showed that the delivered power to the transponder was maintained at 1.48 mW over a range of 6 to 12 cm, while the transmitter power consumption changed from 0.3 W to 1.21 W. The closed loop system can also oppose voltage variations as a result of sudden changes in load current.
An RFID-Based Closed-Loop Wireless Power Transmission System for Biomedical Applications.
Kiani, Mehdi; Ghovanloo, Maysam
2010-04-01
This brief presents a standalone closed-loop wireless power transmission system that is built around a commercial off-the-shelf (COTS) radio-frequency identification (RFID) reader (TRF7960) operating at 13.56 MHz. It can be used for inductively powering implantable biomedical devices in a closed loop. Any changes in the distance and misalignment between transmitter and receiver coils in near-field wireless power transmission can cause a significant change in the received power, which can cause either a malfunction or excessive heat dissipation. RFID circuits are often used in an open loop. However, their back telemetry capability can be utilized to stabilize the received voltage on the implant. Our measurements showed that the delivered power to the transponder was maintained at 11.2 mW over a range of 0.5 to 2 cm, while the transmitter power consumption changed from 78 mW to 1.1 W. The closed-loop system can also oppose voltage variations as a result of sudden changes in the load current.
Wireless Amperometric Neurochemical Monitoring Using an Integrated Telemetry Circuit
Roham, Masoud; Halpern, Jeffrey M.; Martin, Heidi B.; Chiel, Hillel J.
2015-01-01
An integrated circuit for wireless real-time monitoring of neurochemical activity in the nervous system is described. The chip is capable of conducting high-resolution amperometric measurements in four settings of the input current. The chip architecture includes a first-order ΔΣ modulator (ΔΣM) and a frequency-shift-keyed (FSK) voltage-controlled oscillator (VCO) operating near 433 MHz. It is fabricated using the AMI 0.5 μm double-poly triple-metal n-well CMOS process, and requires only one off-chip component for operation. Measured dc current resolutions of ~250 fA, ~1.5 pA, ~4.5 pA, and ~17 pA were achieved for input currents in the range of ±5, ±37, ±150, and ±600 nA, respectively. The chip has been interfaced with a diamond-coated, quartz-insulated, microneedle, tungsten electrode, and successfully recorded dopamine concentration levels as low as 0.5 μM wirelessly over a transmission distance of ~0.5 m in flow injection analysis experiments. PMID:18990633
Wireless amperometric neurochemical monitoring using an integrated telemetry circuit.
Roham, Masoud; Halpern, Jeffrey M; Martin, Heidi B; Chiel, Hillel J; Mohseni, Pedram
2008-11-01
An integrated circuit for wireless real-time monitoring of neurochemical activity in the nervous system is described. The chip is capable of conducting high-resolution amperometric measurements in four settings of the input current. The chip architecture includes a first-order Delta Sigma modulator (Delta Sigma M) and a frequency-shift-keyed (FSK) voltage-controlled oscillator (VCO) operating near 433 MHz. It is fabricated using the AMI 0.5 microm double-poly triple-metal n-well CMOS process, and requires only one off-chip component for operation. Measured dc current resolutions of approximately 250 fA, approximately 1.5 pA, approximately 4.5 pA, and approximately 17 pA were achieved for input currents in the range of +/-5, +/-37, +/-150, and +/-600 nA, respectively. The chip has been interfaced with a diamond-coated, quartz-insulated, microneedle, tungsten electrode, and successfully recorded dopamine concentration levels as low as 0.5 microM wirelessly over a transmission distance of approximately 0.5 m in flow injection analysis experiments.
Impact of a weekly reading program on orthopedic surgery residents' in-training examination.
Weglein, Daniel G; Gugala, Zbigniew; Simpson, Suzanne; Lindsey, Ronald W
2015-05-01
In response to a decline in individual residents' performance and overall program performance on the Orthopaedic In-Training Examination (OITE), the authors' department initiated a daily literature reading program coupled with weekly tests on the assigned material. The goal of this study was to assess the effect of the reading program on individual residents' scores and the training program's OITE scores. The reading program consisted of daily review articles from the Journal of the American Academy of Orthopaedic Surgeons, followed by a weekly written examination consisting of multiple-choice or fill-in-the-blank questions. All articles were selected and all questions were written by the departmental chair. A questionnaire was given to assess residents' perceptions of the weekly tests. As a result of implementing the reading program for a 10-month period, residents' subsequent performance on the OITE significantly improved (mean score increase, 4, P<.0001; percentile score increase, 11, P=.0007). The difference in mean score was significant for residents in postgraduate years 3, 4, and 5. A statistically significant correlation was found between weekly test scores and performance on the OITE, with a significant correlation between weekly test scores and OITE percentile ranking. The study results also showed a positive correlation between reading test attendance and weekly test scores. Residents' anonymous questionnaire responses also demonstrated the reading program to be a valuable addition to the residency training curriculum. In conclusion, the study strongly supports the benefits of a weekly reading and examination program in enhancing the core knowledge of orthopedic surgery residents. Copyright 2015, SLACK Incorporated.
Belloch, Amparo; Roncero, María; Perpiñá, Conxa
2016-11-01
Unwanted intrusive cognitions constitute the normal variant of clinically significant intrusive cognitions found in disorders such as obsessive-compulsive disorder (OCD) and eating disorders (EDs). This study investigates whether individuals who are vulnerable to OCD or EDs experience more intrusions than people with no vulnerability to these disorders, and it examines the consequences of obsessional (OITs) and eating disorder (EDITs) intrusions in the same individuals, taking into account their susceptibility to OCD, EDs or neither of the two. From a sample of 922 participants, three groups were formed: risk of OCD (n = 92), risk of EDs (n = 41) and a no-risk group (n = 100). EDITs were more frequent than OITs in the two risk groups. Within-group comparisons showed that in the OCD-risk group, the OIT had more negative consequences (interference, emotional distress, dysfunctional appraisals and neutralizing strategies) than the EDIT, whereas in the ED-risk group, the OIT and the EDIT instigated similar negative consequences. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association.
Baked Egg and Milk Exposure as Immunotherapy in Food Allergy.
Leonard, Stephanie A
2016-04-01
Baked milk and egg have the potential to act as a form of oral immunotherapy (OIT). Clinical studies have shown that a majority of milk- and egg-allergic children can tolerate these allergens modified in baked form, and immunologic changes reported in subjects ingesting baked milk and egg mirror those seen in food allergy OIT trials. In addition, several studies have indicated that resolution of milk and egg allergies occur sooner in populations regularly ingesting baked milk and egg. Oral food challenges remain the best method for determining tolerability of baked milk and egg since baseline characteristics and diagnostic testing have not been reliable predictors. In this review, we explore the tolerability of baked milk and egg and their potential as OIT treatment for milk and egg allergy.
NASA Astrophysics Data System (ADS)
Calmet, J. F.; Carlin, F.; Nguyen, T. M.; Bousquet, S.; Quinot, P.
2002-03-01
In this paper, correlations between the elongation at break and the oxidation of chlorosulfonated polyethylene and ethylene propylene rubber (EPR) polymers in instrumentation and control cables irradiated at different dose rates are brought to evidence. During irradiation, the following phenomena are observed: an increase of oxygen consumption, a degradation of the mechanical properties and a reduction of the oxidation induction time (OIT) measured for EPR. A correlation between the mechanical properties and the OIT of the EPR has only been established in the case of irradiation at low dose rate. This reveals a difference in the oxidative degradation process at low and high dose rates. This study shows the possibility to assess the ageing of electric cables installed inside nuclear power plants by OIT measurements.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-11
...In this document, the Commission affirms, modifies, and clarifies its actions in response to various petitions for reconsideration and/or clarification. The revised rules are intended to enable Wireless Communications Service (WCS) licensees to deploy broadband services in the 2305-2320 MHz and 2345-2360 MHz (2.3 GHz) WCS bands while continuing to protect Satellite Digital Audio Radio Service (SDARS) operator Sirius XM Radio Inc. (Sirius XM) and aeronautical mobile telemetry (AMT) operations in adjacent bands and the deep space network (DSN) earth station in Goldstone, California from harmful interference. In addition, the revised rules will facilitate the flexible deployment and operation of SDARS terrestrial repeaters in the 2320-2345 MHz SDARS band, while protecting adjacent bands WCS licensees from harmful interference.
A 0.5 cm(3) four-channel 1.1 mW wireless biosignal interface with 20 m range.
Morrison, Tim; Nagaraju, Manohar; Winslow, Brent; Bernard, Amy; Otis, Brian P
2014-02-01
This paper presents a self-contained, single-chip biosignal monitoring system with wireless programmability and telemetry interface suitable for mainstream healthcare applications. The system consists of low-noise front end amplifiers, ADC, MICS/ISM transmitter and infrared programming capability to configure the state of the chip. An on-chip packetizer ensures easy pairing with standard off-the-shelf receivers. The chip is realized in the IBM 130 nm CMOS process with an area of 2×2 mm(2). The entire system consumes 1.07 mW from a 1.2 V supply. It weighs 0.6 g including a zinc-air battery. The system has been extensively tested in in vivo biological experiments and requires minimal human interaction or calibration.
Wireless Telemetry of In-Flight Collision Avoidance Neural Signals in Insects
2010-09-01
with a high LQ product, along with vertical npn transistors (Q1 and Q2) providing a high gm/I ratio with relatively low parasitic capacitance allows...species (pigeon: Sun and Frost, 1998; frog: Kang and Nakagawa, 2006; fish : Preuss et al., 2006; fruit fly: Fotowat et al., 2009). In locusts, this...Eur. J. Neurosci. 7, 981-992. Houweling, A. R. and Brecht, M. (2008). Behavioural report of single neuron stimulation in somatosensory cortex
Mottram, T
2016-10-01
Dairy cows are high value farm animals requiring careful management to achieve the best results. Since the advent of robotic and high throughput milking, the traditional few minutes available for individual human attention daily has disappeared and new automated technologies have been applied to improve monitoring of dairy cow production, nutrition, fertility, health and welfare. Cows milked by robots must meet legal requirements to detect healthy milk. This review focuses on emerging technical approaches in those areas of high cost to the farmer (fertility, metabolic disorders, mastitis, lameness and calving). The availability of low cost tri-axial accelerometers and wireless telemetry has allowed accurate models of behaviour to be developed and sometimes combined with rumination activity detected by acoustic sensors to detect oestrus; other measures (milk and skin temperature, electronic noses, milk yield) have been abandoned. In-line biosensors have been developed to detect markers for ovulation, pregnancy, lactose, mastitis and metabolic changes. Wireless telemetry has been applied to develop boluses for monitoring the rumen pH and temperature to detect metabolic disorders. Udder health requires a multisensing approach due to the varying inflammatory responses collectively described as mastitis. Lameness can be detected by walk over weigh cells, but also by various types of video image analysis and speed measurement. Prediction and detection of calving time is an area of active research mostly focused on behavioural change.
Evaluation of Pediatric Questions on the Orthopaedic In-Training Examination-An Update.
Murphy, Robert F; Nunez, Leah; Barfield, William R; Mooney, James F
2017-09-01
Pediatric orthopaedics is tested frequently on the Orthopaedic In-Training Examination (OITE). The most recent data on the pediatrics section of the OITE were generated from content 10 years old. The purpose of this study is to assess the pediatric orthopaedic questions on the 2011 to 2014 OITE, and to compare question categories and cognitive taxonomy with previous data. Four years (2011 to 2014) of OITE questions, answers, and references were reviewed. The number of pediatric questions per year was recorded, as well as presence of a clinical photo or imaging modality. Each question was categorized and assigned a cognitive taxonomy level. Categories included: knowledge; knowledge-treatment modalities; diagnosis; diagnosis/recognition of associated conditions; diagnosis/further studies; and diagnosis/treatment. Cognitive taxonomy levels included: simple recall, interpretation of data, and advanced problem-solving. The 3 most commonly covered topics were upper extremity trauma (17.4%), scoliosis (10.1%), and developmental dysplasia of the hip (5.7%). Compared with previous data, the percentage of pediatric questions was constant (13% vs. 14%). Categorically, the more recent OITE examinations contained significantly fewer questions testing simple knowledge (19% vs. 39%, P=0.0047), and significantly more questions testing knowledge of treatment modalities (17% vs. 9%, P=0.016) and diagnosis with associated conditions (19% vs. 9%, P=0.0034). Regarding cognitive taxonomy, there was a significant increase in the average number of questions that required advanced problem-solving (57% vs. 46%, P=0.048). Significantly more questions utilized clinical photographs and imaging studies (62% vs. 48%, P=0.012). The most common reference materials provided to support correct responses included Lovell and Winter's Pediatric Orthopaedics (25.7%) and the Journal of Pediatric Orthopaedics (23.4%). Although the percentage of pediatric questions on the OITE has remained essentially constant, the percentage of questions requiring advanced problem-solving or interpretation of images has increased significantly in the past 10 years. Knowledge of question type and content may be helpful for those involved in resident education and in the development of didactic pediatric orthopaedic curricula. Level IV.
Bonfanti, A; Ceravolo, M; Zambra, G; Gusmeroli, R; Spinelli, A S; Lacaita, A L; Angotzi, G N; Baranauskas, G; Fadiga, L
2010-01-01
This paper reports a multi-channel neural recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 16 amplifiers, an analog time division multiplexer, an 8-bit SAR AD converter, a digital signal processor (DSP) and a wireless narrowband 400-MHz binary FSK transmitter. Even though only 16 amplifiers are present in our current die version, the whole system is designed to work with 64 channels demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. A digital data compression, based on the detection of action potentials and storage of correspondent waveforms, allows the use of a 1.25-Mbit/s binary FSK wireless transmission. This moderate bit-rate and a low frequency deviation, Manchester-coded modulation are crucial for exploiting a narrowband wireless link and an efficient embeddable antenna. The chip is realized in a 0.35- εm CMOS process with a power consumption of 105 εW per channel (269 εW per channel with an extended transmission range of 4 m) and an area of 3.1 × 2.7 mm(2). The transmitted signal is captured by a digital TV tuner and demodulated by a wideband phase-locked loop (PLL), and then sent to a PC via an FPGA module. The system has been tested for electrical specifications and its functionality verified in in-vivo neural recording experiments.
Office of Industrial Technologies research in progress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-05-01
The US Department of Energy (DOE) Office of Industrial Technologies (OIT) conducts research and development activities which focus on improving energy efficiency and providing for fuel flexibility within US industry in the area of industrial conservation. The mission of OIT is to increase the utilization of existing energy-efficient equipment and to find and promote new, cost-effective ways for industrial facilities to improve their energy efficiency and minimize waste products. To ensure advancement of the technological leadership of the United States and to improve the competitiveness of American industrial products in world markets, OIT works closely with industrial partners, the staffsmore » of the national laboratories, and universities to identify research and development needs and to solve technological challenges. This report contains summaries of the currently active projects supported by the Office of Industrial Technologies.« less
Yanagida, Noriyuki; Okada, Yu; Sato, Sakura; Ebisawa, Motohiro
2016-04-01
A number of studies have suggested that a large subset of children (approximately 70%) who react to unheated milk or egg can tolerate extensively heated forms of these foods. A diet that includes baked milk or egg is well tolerated and appears to accelerate the development of regular milk or egg tolerance when compared with strict avoidance. However, the indications for an oral food challenge (OFC) using baked products are limited for patients with high specific IgE values or large skin prick test diameters. Oral immunotherapies (OITs) are becoming increasingly popular for the management of food allergies. However, the reported efficacy of OIT is not satisfactory, given the high frequency of symptoms and requirement for long-term therapy. With food allergies, removing the need to eliminate a food that could be consumed in low doses could significantly improve quality of life. This review discusses the importance of an OFC and OIT that use low doses of causative foods as the target volumes. Utilizing an OFC or OIT with a low dose as the target volume could be a novel approach for accelerating the tolerance to causative foods. Copyright © 2015 Japanese Society of Allergology. Production and hosting by Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1980-01-01
St. Jude Medical's Cardiac Rhythm Management Division, formerly known as Pacesetter Systems, Inc., incorporated Apollo technology into the development of the programmable pacemaker system. This consists of the implantable pacemaker together with a physician's console containing the programmer and a data printer. Physician can communicate with patient's pacemaker by means of wireless telemetry signals transmitted through the communicating head held over the patient's chest. Where earlier pacemakers deliver a fixed type of stimulus once implanted, Programalith enables surgery free "fine tuning" of device to best suit the patient's changing needs.
2016-07-04
required analysis, and further testing. 15. SUBJECT TERMS Adjacent Channel Interference, ACI, LTE -A, LTE , PCM/FM, SOQPSK-TG, ARTM CPM, AWS-3, User...Interference, ACI, LTE -A, LTE , PCM/FM, SOQPSK-TG, ARTM CPM, AWS-3, User Equipment, UE, Evolved Node B, eNodeB, Resource Blocks INTRODUCTION “On...these questions make necessary an improved understanding of the interferers that can be obtained only by hands-on measurements . This work will
Hardware platform for multiple mobile robots
NASA Astrophysics Data System (ADS)
Parzhuber, Otto; Dolinsky, D.
2004-12-01
This work is concerned with software and communications architectures that might facilitate the operation of several mobile robots. The vehicles should be remotely piloted or tele-operated via a wireless link between the operator and the vehicles. The wireless link will carry control commands from the operator to the vehicle, telemetry data from the vehicle back to the operator and frequently also a real-time video stream from an on board camera. For autonomous driving the link will carry commands and data between the vehicles. For this purpose we have developed a hardware platform which consists of a powerful microprocessor, different sensors, stereo- camera and Wireless Local Area Network (WLAN) for communication. The adoption of IEEE802.11 standard for the physical and access layer protocols allow a straightforward integration with the internet protocols TCP/IP. For the inspection of the environment the robots are equipped with a wide variety of sensors like ultrasonic, infrared proximity sensors and a small inertial measurement unit. Stereo cameras give the feasibility of the detection of obstacles, measurement of distance and creation of a map of the room.
Wireless multichannel biopotential recording using an integrated FM telemetry circuit.
Mohseni, Pedram; Najafi, Khalil; Eliades, Steven J; Wang, Xiaoqin
2005-09-01
This paper presents a four-channel telemetric microsystem featuring on-chip alternating current amplification, direct current baseline stabilization, clock generation, time-division multiplexing, and wireless frequency-modulation transmission of microvolt- and millivolt-range input biopotentials in the very high frequency band of 94-98 MHz over a distance of approximately 0.5 m. It consists of a 4.84-mm2 integrated circuit, fabricated using a 1.5-microm double-poly double-metal n-well standard complementary metal-oxide semiconductor process, interfaced with only three off-chip components on a custom-designed printed-circuit board that measures 1.7 x 1.2 x 0.16 cm3, and weighs 1.1 g including two miniature 1.5-V batteries. We characterize the microsystem performance, operating in a truly wireless fashion in single-channel and multichannel operation modes, via extensive benchtop and in vitro tests in saline utilizing two different micromachined neural recording microelectrodes, while dissipating approximately 2.2 mW from a 3-V power supply. Moreover, we demonstrate successful wireless in vivo recording of spontaneous neural activity at 96.2 MHz from the auditory cortex of an awake marmoset monkey at several transmission distances ranging from 10 to 50 cm with signal-to-noise ratios in the range of 8.4-9.5 dB.
Chen, Hsin-Yung; Wu, Jin-Shang; Hyland, Brian; Lu, Xiao-Dong; Chen, Jia Jin Jason
2008-08-01
The use of cables for recording neural activity limits the scope of behavioral tests used in conscious free-moving animals. Particularly, cable attachments make it impossible to record in three-dimensional (3D) mazes where levels are vertically stacked or in enclosed spaces. Such environments are of particular interest in investigations of hippocampal place cells, in which neural activity is correlated with spatial position in the environment. We developed a flexible miniaturized Bluetooth-based wireless data acquisition system. The wireless module included an 8-channel analogue front end, digital controller, and Bluetooth transceiver mounted on a backpack. Our bidirectional wireless design allowed all data channels to be previewed at 1 kHz sample rate, and one channel, selected by remote control, to be sampled at 10 kHz. Extracellular recordings of neuronal activity are highly susceptible to ambient electrical noise due to the high electrode impedance. Through careful design of appropriate shielding and hardware configuration to avoid ground loops, mains power and Bluetooth hopping frequency noise were reduced sufficiently to yield signal quality comparable to those recorded by wired systems. With this system we were able to obtain single-unit recordings of hippocampal place cells in rats running an enclosed vertical maze, over a range of 5 m.
Wearable Wireless Telemetry System for Implantable BioMEMS Sensors
NASA Technical Reports Server (NTRS)
Simons, Rainee N.; Miranda, Felix A.; Wilson, Jeffrey D.; Simons, Renita E.
2008-01-01
Telemetry systems of a type that have been proposed for the monitoring of physiological functions in humans would include the following subsystems: Surgically implanted or ingested units that would comprise combinations of microelectromechanical systems (MEMS)- based sensors [bioMEMS sensors] and passive radio-frequency (RF) readout circuits that would include miniature loop antennas. Compact radio transceiver units integrated into external garments for wirelessly powering and interrogating the implanted or ingested units. The basic principles of operation of these systems are the same as those of the bioMEMS-sensor-unit/external-RFpowering- and-interrogating-unit systems described in "Printed Multi-Turn Loop Antennas for Biotelemetry" (LEW-17879-1) NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 48, and in the immediately preceding article, "Hand-Held Units for Short-Range Wireless Biotelemetry" (LEW-17483-1). The differences between what is reported here and what was reported in the cited prior articles lie in proposed design features and a proposed mode of operation. In a specific system of the type now proposed, the sensor unit would comprise mainly a capacitive MEMS pressure sensor located in the annular region of a loop antenna (more specifically, a square spiral inductor/ antenna), all fabricated as an integral unit on a high-resistivity silicon chip. The capacitor electrodes, the spiral inductor/antenna, and the conductor lines interconnecting them would all be made of gold. The dimensions of the sensor unit have been estimated to be about 110.4 mm. The external garment-mounted powering/ interrogating unit would include a multi-turn loop antenna and signal-processing circuits. During operation, this external unit would be positioned in proximity to the implanted or ingested unit to provide for near-field, inductive coupling between the loop antennas, which we have as the primary and secondary windings of an electrical transformer.
Oral desensitization for milk allergy in children: state of the art.
Pajno, Giovanni B
2011-12-01
The purpose of this review is to research current evidence on cow's milk oral immunotherapy for the treatment of cow's milk allergy (CMA). The specific, active treatment for IgE-mediated food allergy included CMA, which is currently being investigated in human trials. Allergen-specific approaches include oral, sublingual and epicutaneous immunotherapy. Reports on oral immunotherapy (OIT) for the treatment of milk allergy have been more extensive and carried out mostly with native proteins. The aim of OIT with cow's milk is the achievement of desensitization or tolerance by patients suffering from CMA. Desensitization state can be achieved by approximately 36-92% of the children treated with specific immunotherapy; the rate of permanent tolerance is unknown. Longer duration of desensitization may result in permanent tolerance. The possibility of adverse events or reactions during OIT is quite frequent. Side-effects have been reported by patients in all published studies. OIT as an active treatment for CMA represents an emerging reality. Before this treatment can be used in clinical practice, additional studies are needed. Currently, many issues remain unanswered: severity and type of food allergy responsive to specific immunotherapy, degree of protection, 'shared schedules' of desensitization(s) in research settings and well established risk-to-benefit ratio. However the field of specific, active treatment of food allergy is poised for clinically important advances.
Froelich, John; Milbrandt, Joseph C; Allan, D Gordon
2009-01-01
This study examines the impact of the 80-hour workweek on the number of surgical cases performed by PGY-2 through PGY-5 orthopedic residents. We also evaluated orthopedic in-training examination (OITE) scores during the same time period. Data were collected from the Accreditation Council for Graduate Medical Education (ACGME) national database for 3 academic years before and 5 years after July 1, 2003. CPT surgical procedure codes logged by all residents 3 years before and 5 years after implementation of the 80-hour workweek were compared. The average raw OITE scores for each class obtained during the same time period were also evaluated. Data were reported as the mean +/- standard deviation (SD), and group means were compared using independent t-tests. No statistical difference was noted in the number of surgical procedure codes logged before or after the institution of the 80-hour week during any single year of training. However, an increase in the number of CPT codes logged in the PGY-3 years after 2003 did approach significance (457.7 vs 551.9, p = 0.057). Overall, the average number of cases performed per resident increased each year after implementation of the work-hour restriction (464.4 vs 515.5 cases). No statistically significant difference was noted in the raw OITE scores before or after work-hour restrictions for our residents or nationally. We found no statistical difference for each residency class in the average number of cases performed or OITE scores, although the total number of cases performed has increased after implementation of the work-hour restrictions. We also found no statistical difference in the national OITE scores. Our data suggest that the impact of the 80-hour workweek has not had a detrimental effect on these 2 resident training measurements.
Analysis of isothiazolinone preservatives in polyvinyl alcohol cooling towels used in Japan.
Kawakami, Tsuyoshi; Isama, Kazuo; Ikarashi, Yoshiaki
2014-09-19
Recently, cases of contact dermatitis that were related to the use of polyvinyl alcohol (PVA) cooling towels containing isothiazolinone preservatives were reported in Japan. The aim of this investigation was to analyze the concentrations of five different isothiazolinone compounds present in PVA towels and to assess the effectiveness of washing in removing the preservatives from new towels prior to being used for the first time. Twenty-seven PVA towels were used in this study. Two groups (i.e., laboratory-simulation and volunteer) of washing experiments were conducted to evaluate the effect of washing procedures. Qualitative and quantitative analyses were performed by LC/MS/MS, which detected 2-methyl-4-isothiazolin-3-one (MI) and 5-chloro-2-methyl-4-isothaizolin-3-one (CMI) in 23 samples (MI: 0.29-154 μg g-wet(-1), CMI: 2.2-467 μg g-wet(-1)), 2-n-octyl-4-isothiazolin-3-one (OIT) in one sample (478 μg g-wet(-1)). The compounds 4,5-Dichloro-2-n-octyl-4-isothiazolin-3-one (2Cl-OIT) and 1,2-benzisothiazolin-3-one (BIT) were not detected in all samples. We confirmed the presence of residual MI, CMI, and OIT in the washed towels, and the residual-to-original content ratio of OIT was higher than that of MI and CMI in PVA towels, due to the higher hydrophobicity of OIT than MI and CMI. A concern has been raised about the occurrence of contact dermatitis being caused by the use of PVA towels. It is suggested that a detailed description of isothiazolinone preservatives in PVA towels and an effective washing procedure for the removal of these preservatives should be provided by the manufacturer. Further, alternative non-sensitizing preservatives might be considered for the manufacture of PVA cooling towels in the future.
Antenna Design Considerations for the Advanced Extravehicular Mobility Unit
NASA Technical Reports Server (NTRS)
Bakula, Casey J.; Theofylaktos, Onoufrios
2015-01-01
NASA is designing an Advanced Extravehicular Mobility Unit (AEMU)to support future manned missions beyond low-Earth orbit (LEO). A key component of the AEMU is the communications assembly that allows for the wireless transfer of voice, video, and suit telemetry. The Extravehicular Mobility Unit (EMU) currently used on the International Space Station (ISS) contains a radio system with a single omni-directional resonant cavity antenna operating slightly above 400 MHz capable of transmitting and receiving data at a rate of about 125 kbps. Recent wireless communications architectures are calling for the inclusion of commercial wireless standards such as 802.11 that operate in higher frequency bands at much higher data rates. The current AEMU radio design supports a 400 MHz band for low-rate mission-critical data and a high-rate band based on commercial wireless local area network (WLAN) technology to support video, communication with non-extravehicular activity (EVA) assets such as wireless sensors and robotic assistants, and a redundant path for mission-critical EVA data. This paper recommends the replacement of the existing EMU antenna with a new antenna that maintains the performance characteristics of the current antenna but with lower weight and volume footprints. NASA has funded several firms to develop such an antenna over the past few years, and the most promising designs are variations on the basic patch antenna. This antenna technology at UHF is considered by the authors to be mature and ready for infusion into NASA AEMU technology development programs.
Wireless implantable electronic platform for chronic fluorescent-based biosensors.
Valdastri, Pietro; Susilo, Ekawahyu; Förster, Thilo; Strohhöfer, Christof; Menciassi, Arianna; Dario, Paolo
2011-06-01
The development of a long-term wireless implantable biosensor based on fluorescence intensity measurement poses a number of technical challenges, ranging from biocompatibility to sensor stability over time. One of these challenges is the design of a power efficient and miniaturized electronics, enabling the biosensor to move from bench testing to long term validation, up to its final application in human beings. In this spirit, we present a wireless programmable electronic platform for implantable chronic monitoring of fluorescent-based autonomous biosensors. This system is able to achieve extremely low power operation with bidirectional telemetry, based on the IEEE802.15.4-2003 protocol, thus enabling over three-year battery lifetime and wireless networking of multiple sensors. During the performance of single fluorescent-based sensor measurements, the circuit drives a laser diode, for sensor excitation, and acquires the amplified signals from four different photodetectors. In vitro functionality was preliminarily tested for both glucose and calcium monitoring, simply by changing the analyte-binding protein of the biosensor. Electronics performance was assessed in terms of timing, power consumption, tissue exposure to electromagnetic fields, and in vivo wireless connectivity. The final goal of the presented platform is to be integrated in a complete system for blood glucose level monitoring that may be implanted for at least one year under the skin of diabetic patients. Results reported in this paper may be applied to a wide variety of biosensors based on fluorescence intensity measurement.
NASA Technical Reports Server (NTRS)
Swank, Aaron J.; Bakula, Casey J.
2012-01-01
In the Fall of 2011, National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) participated in the Desert Research and Technology Studies (DRATS) field experiments held near Flagstaff, Arizona. The objective of the DRATS outing is to provide analog mission testing of candidate technologies for space exploration, especially those technologies applicable to human exploration of extra- terrestrial rocky bodies. These activities are performed at locations with similarities to extra-terrestrial conditions. This report describes the Extravehicular Activity (EVA) Dual-Band Radio Communication System which was demonstrated during the 2011 outing. The EVA radio system is designed to transport both voice and telemetry data through a mobile ad hoc wireless network and employs a dual-band radio configuration. Some key characteristics of this system include: 1. Dual-band radio configuration. 2. Intelligent switching between two different capability wireless networks. 3. Self-healing network. 4. Simultaneous data and voice communication.
Bai, Yu; Bai, Jia-Ming; Li, Jing; Li, Min; Yu, Ran; Pan, Qun-Wan
2014-12-25
The purpose of the present study is to analyze the relationship between the telemetry electroencephalogram (EEG) changes of the prelimbic (PL) cortex and the drug-seeking behavior of morphine-induced conditioned place preference (CPP) rats by using the wavelet packet extraction and entropy measurement. The recording electrode was stereotactically implanted into the PL cortex of rats. The animals were then divided randomly into operation-only control and morphine-induced CPP groups, respectively. A CPP video system in combination with an EEG wireless telemetry device was used for recording EEG of PL cortex when the rats shuttled between black-white or white-black chambers. The telemetry recorded EEGs were analyzed by wavelet packet extraction, Welch power spectrum estimate, normalized amplitude and Shannon entropy algorithm. The results showed that, compared with operation-only control group, the left PL cortex's EEG of morphine-induced CPP group during black-white chamber shuttling exhibited the following changes: (1) the amplitude of average EEG for each frequency bands extracted by wavelet packet was reduced; (2) the Welch power intensity was increased significantly in 10-50 Hz EEG band (P < 0.01 or P < 0.05); (3) Shannon entropy was increased in β, γ₁, and γ₂waves of the EEG (P < 0.01 or P < 0.05); and (4) the average information entropy was reduced (P < 0.01). The results suggest that above mentioned EEG changes in morphine-induced CPP group rat may be related to animals' drug-seeking motivation and behavior launching.
Greenwald, Elliot; Masters, Matthew R; Thakor, Nitish V
2016-01-01
A bidirectional neural interface is a device that transfers information into and out of the nervous system. This class of devices has potential to improve treatment and therapy in several patient populations. Progress in very large-scale integration has advanced the design of complex integrated circuits. System-on-chip devices are capable of recording neural electrical activity and altering natural activity with electrical stimulation. Often, these devices include wireless powering and telemetry functions. This review presents the state of the art of bidirectional circuits as applied to neuroprosthetic, neurorepair, and neurotherapeutic systems.
Bidirectional Neural Interfaces
Masters, Matthew R.; Thakor, Nitish V.
2016-01-01
A bidirectional neural interface is a device that transfers information into and out of the nervous system. This class of devices has potential to improve treatment and therapy in several patient populations. Progress in very-large-scale integration (VLSI) has advanced the design of complex integrated circuits. System-on-chip (SoC) devices are capable of recording neural electrical activity and altering natural activity with electrical stimulation. Often, these devices include wireless powering and telemetry functions. This review presents the state of the art of bidirectional circuits as applied to neuroprosthetic, neurorepair, and neurotherapeutic systems. PMID:26753776
A multi-channel instrumentation system for biosignal recording.
Yu, Hong; Li, Pengfei; Xiao, Zhiming; Peng, Chung-Ching; Bashirullah, Rizwan
2008-01-01
This paper reports a highly integrated battery operated multi-channel instrumentation system intended for physiological signal recording. The mixed signal IC has been fabricated in standard 0.5microm 5V 3M-2P CMOS process and features 32 instrumentation amplifiers, four 8b SAR ADCs, a wireless power interface with Li-ion battery charger, low power bidirectional telemetry and FSM controller with power gating control for improved energy efficiency. The chip measures 3.2mm by 4.8mm and dissipates approximately 2.1mW when fully operational.
Packet loss mitigation for biomedical signals in healthcare telemetry.
Garudadri, Harinath; Baheti, Pawan K
2009-01-01
In this work, we propose an effective application layer solution for packet loss mitigation in the context of Body Sensor Networks (BSN) and healthcare telemetry. Packet losses occur due to many reasons including excessive path loss, interference from other wireless systems, handoffs, congestion, system loading, etc. A call for action is in order, as packet losses can have extremely adverse impact on many healthcare applications relying on BAN and WAN technologies. Our approach for packet loss mitigation is based on Compressed Sensing (CS), an emerging signal processing concept, wherein significantly fewer sensor measurements than that suggested by Shannon/Nyquist sampling theorem can be used to recover signals with arbitrarily fine resolution. We present simulation results demonstrating graceful degradation of performance with increasing packet loss rate. We also compare the proposed approach with retransmissions. The CS based packet loss mitigation approach was found to maintain up to 99% beat-detection accuracy at packet loss rates of 20%, with a constant latency of less than 2.5 seconds.
Use of biologics in severe food allergies.
Fiocchi, Alessandro; Pecora, Valentina; Valluzzi, Rocco L; Fierro, Vincenzo; Mennini, Maurizio
2017-06-01
Severe cases of food allergy account for the majority of the burden in terms of risks, quality of life, and resource expenditure. The traditional approach to these forms has been strict avoidance. More recently, Oral ImmunoTherapy (OIT) has gained a role in their management. However, in severe food allergies OIT is often infeasible. Case reports, observational, and prospective studies have recently proposed different approaches to severe food allergy. The majority of them include the use of biologics. Omalizumab has been the most studied drug for severe food allergies, and its role as adjuvant treatment to OIT is well established. Interest has been raised on other biologics, as dupilumab, reslizumab, and mepolizumab. Toll-like receptor agonists, and gene therapy using adeno-associated virus coding for Omalizumab are promising alternatives. The recent studies are deeply influencing the clinical practice. We review the modifications of the clinical approach to severe food allergies so far available. We indicate the possible evolutions of treatment with biologics in severe food allergies.
NASA Astrophysics Data System (ADS)
Barnhart, K.; Oden, C. P.
2012-12-01
The dissolution of soluble bedrock results in surface and subterranean karst channels, which comprise 7-10% of the dry earth's surface. Karst serves as a preferential conduit to focus surface and subsurface water but it is difficult to exploit as a water resource or protect from pollution because of irregular structure and nonlinear hydrodynamic behavior. Geophysical characterization of karst commonly employs resistivity and seismic methods, but difficulties arise due to low resistivity contrast in arid environments and insufficient resolution of complex heterogeneous structures. To help reduce these difficulties, we employ a state-of-the-art wireless geophysical sensor array, which combines low-power radio telemetry and solar energy harvesting to enable long-term in-situ monitoring. The wireless aspect removes topological constraints common with standard wired resistivity equipment, which facilitates better coverage and/or sensor density to help improve aspect ratio and resolution. Continuous in-situ deployment allows data to be recorded according to nature's time scale; measurements are made during infrequent precipitation events which can increase resistivity contrast. The array is coordinated by a smart wireless bridge that continuously monitors local soil moisture content to detect when precipitation occurs, schedules resistivity surveys, and periodically relays data to the cloud via 3G cellular service. Traditional 2/3D gravity and seismic reflection surveys have also been conducted to clarify and corroborate results.
An integrated multiscale river basin observing system in the Heihe River Basin, northwest China
NASA Astrophysics Data System (ADS)
Li, X.; Liu, S.; Xiao, Q.; Ma, M.; Jin, R.; Che, T.
2015-12-01
Using the watershed as the unit to establish an integrated watershed observing system has been an important trend in integrated eco-hydrologic studies in the past ten years. Thus far, a relatively comprehensive watershed observing system has been established in the Heihe River Basin, northwest China. In addition, two comprehensive remote sensing hydrology experiments have been conducted sequentially in the Heihe River Basin, including the Watershed Allied Telemetry Experimental Research (WATER) (2007-2010) and the Heihe Watershed Allied Telemetry Experimental Research (HiWATER) (2012-2015). Among these two experiments, an important result of WATER has been the generation of some multi-scale, high-quality comprehensive datasets, which have greatly supported the development, improvement and validation of a series of ecological, hydrological and quantitative remote-sensing models. The goal of a breakthrough for solving the "data bottleneck" problem has been achieved. HiWATER was initiated in 2012. This project has established a world-class hydrological and meteorological observation network, a flux measurement matrix and an eco-hydrological wireless sensor network. A set of super high-resolution airborne remote-sensing data has also been obtained. In addition, there has been important progress with regard to the scaling research. Furthermore, the automatic acquisition, transmission, quality control and remote control of the observational data has been realized through the use of wireless sensor network technology. The observation and information systems have been highly integrated, which will provide a solid foundation for establishing a research platform that integrates observation, data management, model simulation, scenario analysis and decision-making support to foster 21st-century watershed science in China.
NASA Astrophysics Data System (ADS)
Chow, Eric Y.
Glaucoma affects about 65 million people and is the second leading cause of blindness in the world. Although the condition is irreversible and incurable, early detection is vital to slowing and even stopping the progression of the disease. Our work focuses on the design, fabrication, and assembly of a continuous active glaucoma intraocular pressure (IOP) monitor that provides clinicians with the necessary data to more accurately diagnose and treat patients. Major benefits of an active monitoring device include the potential to develop a closed-loop treatment system and to operate independently for extended periods of time. The fully wireless operation uses gigahertzfrequency electromagnetic wave propagation, which allows for an orientation independent transfer of power and data over reasonable distances. Our system is comprised of a MEMS capacitive sensor, capacitive power storage array, ASIC, and monopole antenna assembled into a biocompatible liquid crystal polymer (LCP) package. We have performed in vivo trials on rabbits, both chronic and acute, to validate system functionality, fully wireless feasibility, and biocompatibility. Heart failure (HF) affects approximately 2% of the adult population in developed countries and 6-10% of people over the age of 65. Continuous monitoring of blood pressure, flow, and chemistry from a minimally invasive device can serve as a diagnostic and early-warning system for cardiac health. We developed a miniaturized system attached to the outer surface of an FDA approved stent, used as both the antenna for wireless telemetry/powering and structural support. The system comprises of a MEMS pressure sensor, ASIC for the sensor interface and wireless capabilities, LCP substrate, and FDA approved stent. In vivo studies on pigs validated functionality and fully wireless operation and demonstrate the feasibility of a stent-based wireless implant for continuous monitoring of blood pressure as well as other parameters including oxygen, flow and turbulence, chemistry, and glucose.
Cow's Milk Desensitization in Anaphylactic Patients: A New Personalized-dose Method.
Babaie, Delara; Nabavi, Mohammad; Arshi, Saba; Mesdaghi, Mehrnaz; Chavoshzadeh, Zahra; Bemanian, Mohammad Hasan; Tafakori, Mitra; Amirmoini, Mehrdad; Esmailzadeh, Hosein; Molatefi, Rasoul; Rekabi, Mahsa; Akbarpour, Nadieh; Masoumi, Farimah; Fallahpour, Morteza
2017-02-01
Cow's milk allergy (CMA) is the most frequent food allergy in children and oral immunotherapy (OIT) is a promising approach for treatment of patients. The most challenging cases are anaphylactic with coexisting asthma and proposing safe protocols is crucial especially in high risk groups. Considering that CMA varies among patients, an individualized OIT protocol would be beneficial to achieve a safer and more efficient method of desensitization. 18 children more than 3 years of age with IgE-mediated CMA were enrolled. CMA was confirmed by positive skin prick test (SPT) and positive oral food challenge (OFC) and 60% of individuals had a convincing history of persistent asthma. SPT with milk extracts, whole fresh milk and serially diluted milk concentrations were performed. The dilution of milk that induced 3-5 mm of wheal in each individual was selected as the starting dilution for OIT. Desensitization began by 1 drop of the defined dilution and continued increasingly. Overall, 16 out of 18 children (88.8%) achieved the daily intake of 120 mL of milk. Four out of these 16 children accomplished the protocol without any adverse allergic reactions. 12 patients experienced mild to severe reactions. Wheal and erythema in SPT (p≤0.001), and sIgE (p≤0.003) to most milk allergens were significantly decreased following desensitization. We successfully desensitized 16 of 18 children with IgE-mediated CMA by individualized desensitization protocol. Individualizing the OIT protocol would be helpful to save time and perhaps to relieve the allergic symptoms after ingesting cow's milk intake.
Resident selection: how we are doing and why?
Thordarson, David B; Ebramzadeh, Edward; Sangiorgio, Sophia N; Schnall, Stephen B; Patzakis, Michael J
2007-06-01
Selection of the best applicants for orthopaedic residency programs remains a difficult problem. Most quantifiable factors for residency selection evaluate test-taking ability and grades rather than other aspects, such as patient care, professionalism, moral reasoning, and integrity. Four current department members on our resident selection committee ranked four consecutive classes of orthopaedic residents interviewed for residency. We ranked incoming residents in order of best to least qualified and compared those rankings with rank lists by the same faculty on completion of residency. Rankings also were compared with the residents' United States Medical Licensing Examination (USMLE) Part I scores, American Board of Orthopaedic Surgery (ABOS) Part I scores, and fourth-year Orthopaedic-in-Training Examination (OITE) scores. We found fair or poor correlations between the residents' initial rankings, rankings on graduation, and their USMLE, ABOS, and OITE scores. The only relatively strong correlation found was between the OITE and ABOS scores. Despite the faculty's consensus regarding selection criteria, interviewers did not agree in their rankings of residents on graduation. Additional work is necessary to refine the inexact yet important science of selecting residency applicants.
Aerts, Olivier; Goossens, An; Lambert, Julien; Lepoittevin, Jean-Pierre
2017-04-01
The isothiazolinone derivatives, methylchloroisothiazolinone (MCI), methylisothiazolinone (MI), benzisothiazolinone (BIT), and octylisothiazolinone (OIT), owing to their strong bactericide, fungicide and algicide properties, are widely used in non-cosmetic products, such as chemical (industrial) products, household detergents, and water-based paints, and the former two derivatives are also used in cosmetic products. However, given their inherent sensitization potential (with MCI > MI > BIT > OIT), allergic contact dermatitis is frequently observed, both in consumers as well as workers in various industries. In this review, we provide an update on the use of MCI/MI and MI in cosmetics, highlighting certain aspects of MI; the use of excessive concentrations, the presence in some less familiar cosmetic products, and the association with unusual clinical manifestations. Furthermore, the use of isothiazolinones in dish-washing and washing-machine liquids, cleaning agents for dental care, and their general presence in multi-purpose household detergents, which may elicit (airborne) allergic contact dermatitis, is discussed. Finally, we provide a brief overview of the use of isothiazolinone derivatives in the paint and textile industry, and of OIT in the leather industry in particular.
Oxidative induction time -- A review of DSC experimental effects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blaine, R.L.; Lundgren, C.J.; Harris, M.B.
1997-12-31
Over the past several years, a number of ASTM committees have explored a wide variety of experimental parameters affecting the oxidative induction time (OIT) test method in an attempt to improve its intra- and inter-laboratory precision. These studies have identified test temperature precision as a key parameter affecting OIT precision. Other parameters of importance are oxygen flow rate, specimen size, specimen pan type, oxygen pressure and catalyst effects. The work of Kuck, Bowmer, Riga, Tikuisis and Thomas are reviewed as well as the collective work of ASTM Committees E37, D2, D9 and D35.
NASA Technical Reports Server (NTRS)
1982-01-01
Neurodyne Corporation Human Tissue Stimulator (HTS) is a totally implantable system used for treatment of chronic pain and involuntary motion disorders by electrical stimulation. It was developed by Pacesetter Systems, Inc. in cooperation with the Applied Physics Laboratory. HTS incorporates a nickel cadmium battery, telemetry and command systems technologies of the same type as those used in NASA's Small Astronomy Satellite-3 in microminiature proportions so that the implantable element is the size of a deck of cards. The stimulator includes a rechargeable battery, an antenna and electronics to receive and process commands and to report on its own condition via telemetry, a wireless process wherein instrument data is converted to electrical signals and sent to a receiver where signals are presented as usable information. The HTS is targeted to nerve centers or to particular areas of the brain to provide relief from intractable pain or arrest involuntary motion. The nickel cadmium battery can be recharged through the skin. The first two HTS units were implanted last year and have been successful. Extensive testing is required before HTS can be made available for general use.
A telemetry system embedded in clothes for indoor localization and elderly health monitoring.
Charlon, Yoann; Fourty, Nicolas; Campo, Eric
2013-09-04
This paper presents a telemetry system used in a combined trilateration method for the precise indoor localization of the elderly who need health monitoring. The system is based on the association of two wireless technologies: ultrasonic and 802.15.4. The use of the 802.15.4 RF signal gives the reference starting time of the ultrasonic emission (time difference of arrival method). A time of flight measurement of the ultrasonic pulses provides the distances between the mobile node and three anchor points. These distance measurements are then used to locate the mobile node using the trilateration method with an accuracy of a few centimetres. The originality of our work lies in embedding the mobile node in clothes. The system is embedded in clothes in two ways: on a shoe in order to form a "smart" shoe and in a hat in order to form a "smart" hat. Both accessories allow movements, gait speed and distance covered to be monitored for health applications. Experiments in a test room are presented to show the effectiveness of our system.
A system verification platform for high-density epiretinal prostheses.
Chen, Kuanfu; Lo, Yi-Kai; Yang, Zhi; Weiland, James D; Humayun, Mark S; Liu, Wentai
2013-06-01
Retinal prostheses have restored light perception to people worldwide who have poor or no vision as a consequence of retinal degeneration. To advance the quality of visual stimulation for retinal implant recipients, a higher number of stimulation channels is expected in the next generation retinal prostheses, which poses a great challenge to system design and verification. This paper presents a system verification platform dedicated to the development of retinal prostheses. The system includes primary processing, dual-band power and data telemetry, a high-density stimulator array, and two methods for output verification. End-to-end system validation and individual functional block characterization can be achieved with this platform through visual inspection and software analysis. Custom-built software running on the computers also provides a good way for testing new features before they are realized by the ICs. Real-time visual feedbacks through the video displays make it easy to monitor and debug the system. The characterization of the wireless telemetry and the demonstration of the visual display are reported in this paper using a 256-channel retinal prosthetic IC as an example.
Echeverria, L; Martin-Muñoz, M F; Martorell, C; Belver, M T; Alonso Lebrero, E; Zapatero, L; Fuentes, V; Piqué, M; Plaza, A; Muñoz, C; Martorell, A; Blasco, C; Villa, B; Gómez, C; Nevot, S; García, J M; Madero, R
2018-05-24
In children with egg protein allergy (EA), the probability of overcoming the allergy decreases with age, and the possibility of suffering severe adverse reactions as a consequence of dietetic transgressions results in worsened quality of life. One treatment option in such cases is oral immunotherapy (OIT) with foods. We present a cohort of children with EA scheduled for OIT with pasteurized raw egg white, describing their clinical and allergic characteristics before the start of OIT. The median age was six years, and 93% of the patients also suffered other allergies (58% asthma and 38.6% allergy to more than two food groups). In the last year, 14.8% had suffered a severe reaction due to dietetic transgression with egg. The median IgE specific of egg white titer was 38.5kU/l. A double-blind placebo-controlled food challenge with cooked egg white was performed, and if the test proved positive, it was repeated with pasteurized raw egg white. The mean symptoms-provoking dose was 1.26g and 0.55g for cooked egg white and raw egg white, respectively. An IgE specific of ovomucoid titer of <2.045kU/l differentiated those patients that tolerated cooked egg white. OIT with egg is regarded as an option in patients with persistent egg allergy. In the previous challenge test, an IgE specific of ovomucoid titer of <2.045kU/l differentiates those patients that tolerate cooked egg white. Copyright © 2018 SEICAP. Published by Elsevier España, S.L.U. All rights reserved.
Development of an extensible dual-core wireless sensing node for cyber-physical systems
NASA Astrophysics Data System (ADS)
Kane, Michael; Zhu, Dapeng; Hirose, Mitsuhito; Dong, Xinjun; Winter, Benjamin; Häckell, Mortiz; Lynch, Jerome P.; Wang, Yang; Swartz, A.
2014-04-01
The introduction of wireless telemetry into the design of monitoring and control systems has been shown to reduce system costs while simplifying installations. To date, wireless nodes proposed for sensing and actuation in cyberphysical systems have been designed using microcontrollers with one computational pipeline (i.e., single-core microcontrollers). While concurrent code execution can be implemented on single-core microcontrollers, concurrency is emulated by splitting the pipeline's resources to support multiple threads of code execution. For many applications, this approach to multi-threading is acceptable in terms of speed and function. However, some applications such as feedback controls demand deterministic timing of code execution and maximum computational throughput. For these applications, the adoption of multi-core processor architectures represents one effective solution. Multi-core microcontrollers have multiple computational pipelines that can execute embedded code in parallel and can be interrupted independent of one another. In this study, a new wireless platform named Martlet is introduced with a dual-core microcontroller adopted in its design. The dual-core microcontroller design allows Martlet to dedicate one core to standard wireless sensor operations while the other core is reserved for embedded data processing and real-time feedback control law execution. Another distinct feature of Martlet is a standardized hardware interface that allows specialized daughter boards (termed wing boards) to be interfaced to the Martlet baseboard. This extensibility opens opportunity to encapsulate specialized sensing and actuation functions in a wing board without altering the design of Martlet. In addition to describing the design of Martlet, a few example wings are detailed, along with experiments showing the Martlet's ability to monitor and control physical systems such as wind turbines and buildings.
NASA Astrophysics Data System (ADS)
Ahmad, Afandi; Roslan, Muhammad Faris; Amira, Abbes
2017-09-01
In high jump sports, approach take-off speed and force during the take-off are two (2) main important parts to gain maximum jump. To measure both parameters, wireless sensor network (WSN) that contains microcontroller and sensor are needed to describe the results of speed and force for jumpers. Most of the microcontroller exhibit transmission issues in terms of throughput, latency and cost. Thus, this study presents the comparison of wireless microcontrollers in terms of throughput, latency and cost, and the microcontroller that have best performances and cost will be implemented in high jump wearable device. In the experiments, three (3) parts have been integrated - input, process and output. Force (for ankle) and global positioning system (GPS) sensor (for body waist) acts as an input for data transmission. These data were then being processed by both microcontrollers, ESP8266 and Arduino Yun Mini to transmit the data from sensors to the server (host-PC) via message queuing telemetry transport (MQTT) protocol. The server acts as receiver and the results was calculated from the MQTT log files. At the end, results obtained have shown ESP8266 microcontroller had been chosen since it achieved high throughput, low latency and 11 times cheaper in term of prices compared to Arduino Yun Mini microcontroller.
A hybrid optic-fiber sensor network with the function of self-diagnosis and self-healing
NASA Astrophysics Data System (ADS)
Xu, Shibo; Liu, Tiegen; Ge, Chunfeng; Chen, Cheng; Zhang, Hongxia
2014-11-01
We develop a hybrid wavelength division multiplexing optical fiber network with distributed fiber-optic sensors and quasi-distributed FBG sensor arrays which detect vibrations, temperatures and strains at the same time. The network has the ability to locate the failure sites automatically designated as self-diagnosis and make protective switching to reestablish sensing service designated as self-healing by cooperative work of software and hardware. The processes above are accomplished by master-slave processors with the help of optical and wireless telemetry signals. All the sensing and optical telemetry signals transmit in the same fiber either working fiber or backup fiber. We take wavelength 1450nm as downstream signal and wavelength 1350nm as upstream signal to control the network in normal circumstances, both signals are sent by a light emitting node of the corresponding processor. There is also a continuous laser wavelength 1310nm sent by each node and received by next node on both working and backup fibers to monitor their healthy states, but it does not carry any message like telemetry signals do. When fibers of two sensor units are completely damaged, the master processor will lose the communication with the node between the damaged ones.However we install RF module in each node to solve the possible problem. Finally, the whole network state is transmitted to host computer by master processor. Operator could know and control the network by human-machine interface if needed.
Allergen-specific oral immunotherapy for peanut allergy.
Nurmatov, Ulugbek; Venderbosch, Iris; Devereux, Graham; Simons, F Estelle R; Sheikh, Aziz
2012-09-12
Peanut allergy is one of the most common forms of food allergy encountered in clinical practice. In most cases, it does not spontaneously resolve; furthermore, it is frequently implicated in acute life-threatening reactions. The current management of peanut allergy centres on meticulous avoidance of peanuts and peanut-containing foods. Allergen-specific oral immunotherapy (OIT) for peanut allergy aims to induce desensitisation and then tolerance to peanut, and has the potential to revolutionise the management of peanut allergy. However, at present there is still considerable uncertainty about the effectiveness and safety of this approach. To establish the effectiveness and safety of OIT in people with IgE-mediated peanut allergy who develop symptoms after peanut ingestion. We searched in the following databases: AMED, BIOSIS, CAB, CINAHL, The Cochrane Library, EMBASE, Global Health, Google Scholar, IndMed, ISI Web of Science, LILACS, MEDLINE, PakMediNet and TRIP. We also searched registers of on-going and unpublished trials. The date of the most recent search was January 2012. Randomised controlled trials (RCTs), quasi-RCTs or controlled clinical trials involving children or adults with clinical features indicative of IgE-mediated peanut allergy treated with allergen-specific OIT, compared with control group receiving either placebo or no treatment, were eligible for inclusion. Two review authors independently checked and reviewed titles and abstracts of identified studies and assessed risk of bias. The full text of potentially relevant trials was assessed. Data extraction was independently performed by two reviewers with disagreements resolved through discussion. We found one small RCT, judged to be at low risk of bias, that enrolled 28 children aged 1 to 16 years with evidence of sensitisation to peanut and a clinical history of reaction to peanut within 60 minutes of exposure. The study did not include children who had moderate to severe asthma or who had a history of severe peanut anaphylaxis. Randomisation was in a 2:1 ratio resulting in 19 children being randomised to the intervention arm and nine to the placebo arm. Intervention arm children received OIT with peanut flour and control arm participants received placebo comprising of oat flour. The primary outcome was assessed using a double-blind, placebo controlled oral food challenge (OFC) at approximately one year. No data were available on longer term outcomes beyond the OFC conducted at the end of the study.Because of adverse events, three patients withdrew from the intervention arm before the completion of the study. Therefore, only 16 participants received the full course of peanut OIT, whereas all nine patients receiving placebo completed the trial. The per-protocol analysis found a significant increase in the threshold dose of peanut allergen required to trigger a reaction in those in the intervention arm with all 16 participants able to ingest the maximum cumulative dose of 5000 mg of peanut protein (which the authors equate as being equivalent to approximately 20 peanuts) without developing symptoms, whereas in the placebo group they were able to ingest a median cumulative dose of 280 mg (range: 0 to 1900 mg, P < 0.001) before experiencing symptoms. Per-protocol analyses also demonstrated that peanut OIT resulted in reductions in skin prick test size (P < 0.001), interleukin-5 (P = 0.01), interleukin-13 (P = 0.02) and an increase in peanut-specific immunoglobulin G(4) (IgG(4)) (P < 0.01).Children in the intervention arm experienced more adverse events during treatment than those in the placebo arm. In the initial day escalation phase, nine (47%) of the 19 participants initially enrolled in the OIT arm experienced clinically-relevant adverse events which required treatment with H(1)-antihistamines, two of which required additional treatment with epinephrine (adrenaline). The one small RCT we found showed that allergen-specific peanut OIT can result in desensitisation in children, and that this is associated with evidence of underlying immune-modulation. However, this treatment approach was associated with a substantial risk of adverse events, although the majority of these were mild. In view of the risk of adverse events and the lack of evidence of long-term benefits, allergen-specific peanut OIT cannot currently be recommended as a treatment for the management of patients with IgE-mediated peanut allergy. Larger RCTs are needed to investigate the acceptability, long-term effectiveness and cost-effectiveness of safer treatment regimens, particularly in relation to the induction of clinical and immunological tolerance.
Environmental Monitoring Using Sensor Networks
NASA Astrophysics Data System (ADS)
Yang, J.; Zhang, C.; Li, X.; Huang, Y.; Fu, S.; Acevedo, M. F.
2008-12-01
Environmental observatories, consisting of a variety of sensor systems, computational resources and informatics, are important for us to observe, model, predict, and ultimately help preserve the health of the nature. The commoditization and proliferation of coin-to-palm sized wireless sensors will allow environmental monitoring with unprecedented fine spatial and temporal resolution. Once scattered around, these sensors can identify themselves, locate their positions, describe their functions, and self-organize into a network. They communicate through wireless channel with nearby sensors and transmit data through multi-hop protocols to a gateway, which can forward information to a remote data server. In this project, we describe an environmental observatory called Texas Environmental Observatory (TEO) that incorporates a sensor network system with intertwined wired and wireless sensors. We are enhancing and expanding the existing wired weather stations to include wireless sensor networks (WSNs) and telemetry using solar-powered cellular modems. The new WSNs will monitor soil moisture and support long-term hydrologic modeling. Hydrologic models are helpful in predicting how changes in land cover translate into changes in the stream flow regime. These models require inputs that are difficult to measure over large areas, especially variables related to storm events, such as soil moisture antecedent conditions and rainfall amount and intensity. This will also contribute to improve rainfall estimations from meteorological radar data and enhance hydrological forecasts. Sensor data are transmitted from monitoring site to a Central Data Collection (CDC) Server. We incorporate a GPRS modem for wireless telemetry, a single-board computer (SBC) as Remote Field Gateway (RFG) Server, and a WSN for distributed soil moisture monitoring. The RFG provides effective control, management, and coordination of two independent sensor systems, i.e., a traditional datalogger-based wired sensor system and the WSN-based wireless sensor system. The RFG also supports remote manipulation of the devices in the field such as the SBC, datalogger, and WSN. Sensor data collected from the distributed monitoring stations are stored in a database (DB) Server. The CDC Server acts as an intermediate component to hide the heterogeneity of different devices and support data validation required by the DB Server. Daemon programs running on the CDC Server pre-process the data before it is inserted into the database, and periodically perform synchronization tasks. A SWE-compliant data repository is installed to enable data exchange, accepting data from both internal DB Server and external sources through the OGC web services. The web portal, i.e. TEO Online, serves as a user-friendly interface for data visualization, analysis, synthesis, modeling, and K-12 educational outreach activities. It also provides useful capabilities for system developers and operators to remotely monitor system status and remotely update software and system configuration, which greatly simplifies the system debugging and maintenance tasks. We also implement Sensor Observation Services (SOS) at this layer, conforming to the SWE standard to facilitate data exchange. The standard SensorML/O&M data representation makes it easy to integrate our sensor data into the existing Geographic Information Systems (GIS) web services and exchange the data with other organizations.
Monitoring Heart Disease and Diabetes with Mobile Internet Communications
Mulvaney, David; Woodward, Bryan; Datta, Sekharjit; Harvey, Paul; Vyas, Anoop; Thakker, Bhaskar; Farooq, Omar; Istepanian, Robert
2012-01-01
A telemedicine system is described for monitoring vital signs and general health indicators of patients with cardiac and diabetic conditions. Telemetry from wireless sensors and readings from other instruments are combined into a comprehensive set of measured patient parameters. Using a combination of mobile device applications and web browser, the data can be stored, accessed, and displayed using mobile internet communications to the central server. As an extra layer of security in the data transmission, information embedded in the data is used in its verification. The paper highlights features that could be enhanced from previous systems by using alternative components or methods. PMID:23213330
Space Derived Health Aids (Cardiac Pacemaker)
NASA Technical Reports Server (NTRS)
1981-01-01
St. Jude Medical's Cardiac Rhythm Management Division's (formerly known as Pacesetter Systems, Inc.) pacer is a rechargeable cardiac pacemaker that eliminates the recurring need for surgery to implant a new battery. The Programalith is an advanced cardiac pacing system which permits a physician to reprogram a patient's implanted pacemaker without surgery. System consists of a pacemaker, together with a physician's console containing the programmer and a data printer. Signals are transmitted by wireless telemetry. Two-way communications, originating from spacecraft electrical power systems technology, allows physician to interrogate the pacemaker as to the status of the heart, then to fine tune the device to best suit the patient's needs.
Zhang, Wen-Qiang; Yan, Guo-Zheng; Yu, Lian-Zhi; Yang, Xin-Qing
2006-01-01
AIM: To study the prolonged colonic motility under normal conditions with a novel capsule-style micro-system and to assess its clinical significance. METHODS: A single use telemetry capsule (10 mm in diameter, 20 mm in length) embedded with a pressure sensor was ingested by the subjects. The sensor is capable of transmitting colonic pressure wirelessly for more than 130 h. The time of capsule entering the segmental colon was detected by ultrasound. The ultrasonic electrodes were mounted on the surface of the ileocecum and navel and at the junction of the left and rectosigmoid colon of the subjects in sequence, which were identified by abdominal X-rays with radiopaque markers. To verify the accuracy and reliability of ultrasonic detection of telemetry capsules at key points of colon, the segmental colonic transit time was simultaneously recorded by using radiopaque markers. RESULTS: The signal lamp showed that all recorders could receive the radio signal transmitted by the telemetry capsule. The X-rays showed that all telemetry capsules were detected successfully when they were passing through the key points of colon. There was a significant correlation between the transit results obtained by ultrasonic detection or by radiopaque markers. Colorectal recording was obtained from 20 healthy subjects during 613 h (411 h during waking, 202 h during sleep). Compared to waking, the number of pressure contractions and the area under pressure contractions were significantly (P < 0.05) decreased during sleep (21 ± 5 h-1 vs 15 ± 4 h-1, 463 ± 54 mmHg·s/min vs 342 ± 45 mmHg·s/min). The colonic motility exhibited significant regional variations both in the circadian behavior and in response to waking and meal. CONCLUSION: The capsule-style micro-system is reliable and noninvasive, and may represent a useful tool for the study of physiology and pathology of colonic motor disorders. PMID:17171801
NASA Technical Reports Server (NTRS)
Nichols, Kelvin F.; Best, Susan; Schneider, Larry
2004-01-01
With so many security issues involved with wireless networks, the technology has not been fully utilized in the area of mission critical applications. These applications would include the areas of telemetry, commanding, voice and video. Wireless networking would allow payload operators the mobility to take computers outside of the control room to their offices and anywhere else in the facility that the wireless network was extended. But the risk is too great of having someone sit just inside of your wireless network coverage and intercept enough of your network traffic to steal proprietary data from a payload experiment or worse yet hack back into your system and do even greater harm by issuing harmful commands. Wired Equivalent Privacy (WEP) is improving but has a ways to go before it can be trusted to protect mission critical data. Today s hackers are becoming more aggressive and innovative, and in order to take advantage of the benefits that wireless networking offer, appropriate security measures need to be in place that will thwart hackers. The Virtual Private Network (VPN) offers a solution to the security problems that have kept wireless networks from being used for mission critical applications. VPN provides a level of encryption that will ensure that data is protected while it is being transmitted over a wireless local area network (IAN). The VPN allows a user to authenticate to the site that the user needs to access. Once this authentication has taken place the network traffic between that site and the user is encapsulated in VPN packets with the Triple Data Encryption Standard (3DES). 3DES is an encryption standard that uses a single secret key to encrypt and decrypt data. The length of the encryption key is 168 bits as opposed to its predecessor DES that has a 56-bit encryption key. Even though 3DES is the common encryption standard for today, the Advance Encryption Standard (AES), which provides even better encryption at a lower cycle cost is growing acceptance. The user computer running the VPN client and the. target site that is running the . VPN firewall exchange this encryption key and therefore are the only ones that are able to decipher the data. The level of encryption offered by the VPN is making it possible for wireless networks to pass the strict security policies that have kept them from being used in the past. Now people will be able to benefit from the many advantages that wireless networking has to offer in the area of mission critical applications.
NASA Technical Reports Server (NTRS)
Nichols, Kelvin F.; Best, Susan; Schneider, Larry
2004-01-01
With so many security issues involved with wireless networks, the technology has not been fully utilized in the area of mission critical applications. These applications would include the areas of telemetry, commanding, voice and video. Wireless networking would allow payload operators the mobility to take computers outside of the control room to their off ices and anywhere else in the facility that the wireless network was extended. But the risk is too great of having someone sit just inside of your wireless network coverage and intercept enough of your network traffic to steal proprietary data from a payload experiment or worse yet hack back into your system and do even greater harm by issuing harmful commands. Wired Equivalent Privacy (WEP) is improving but has a ways to go before it can be trusted to protect mission critical data. Today s hackers are becoming more aggressive and innovative, and in order to take advantage of the benefits that wireless networking offer, appropriate security measures need to be in place that will thwart hackers. The Virtual Private Network (VPN) offers a solution to the security problems that have kept wireless networks from being used for mission critical applications. VPN provides a level of encryption that will ensure that data is protected while it is being transmitted over a wireless local area network (LAN). The VPN allows a user to authenticate to the site that the user needs to access. Once this authentication has taken place the network traffic between that site and the user is encapsulated in VPN packets with the Triple Data Encryption Standard (3DES). 3DES is an encryption standard that uses a single secret key to encrypt and decrypt data. The length of the encryption key is 168 bits as opposed to its predecessor DES that has a 56-bit encryption key. Even though 3DES is the common encryption standard for today, the Advance Encryption Standard (AES), which provides even better encryption at a lower cycle cost is growing acceptance. The user computer running the VPN client and the target site that is running the VPN firewall exchange this encryption key and therefore are the only ones that are able to decipher the data. The level of encryption offered by the VPN is making it possible for wireless networks to pass the strict security policies that have kept them from being used in the past. Now people will be able to benefit from the many advantages that wireless networking has to offer in the area of mission critical applications.
Sato, Sakura; Yanagida, Noriyuki; Ohtani, Kiyotaka; Koike, Yumi; Ebisawa, Motohiro
2015-06-01
The purpose of this study is to assess the latest studies that focus on specific immunoglobulin (Ig)E antibodies for predicting clinical reactivity to foods. Persistent hen's egg and cow's milk allergy patients have higher antigen-specific IgE levels at all ages than those who have outgrown these allergies. Recent studies on the natural histories of hen's egg and cow's milk allergies suggested that baseline antigen-specific IgEs are the most important predictors of tolerance. Oral immunotherapy (OIT), which is a novel therapeutic approach for food allergy, requires biomarkers for predicting outcomes after therapy. Several studies indicate that the initial antigen-specific IgE level may be a useful biomarker for the prognosis of OIT. Recently, component-resolved diagnostics (CRD) has been used for food allergy diagnosis. Current studies have suggested that Ara h 2, omega-5 gliadin and ovomucoid are good diagnostic markers for peanut, wheat and egg allergies, respectively. Antigen-specific IgE can be a useful biomarker for predicting clinical reactivity to food allergies. Monitoring hen's egg and cow's milk-specific IgE is useful for predicting prognosis, and baseline specific IgE levels may be associated with the outcome of OIT. The use of CRD provides us with a better tool for diagnosing food allergy.
Implantable telemetry capsule for monitoring arterial oxygen saturation and heartbeat.
Kuwana, K; Dohi, T; Hashimoto, Y; Matsumoto, K; Shimoyama, I
2008-01-01
In this study, we have developed an implantable telemetry capsule for monitoring heartbeat. The capsule has three main functions, monitoring vital signs, transmitting the vital signs, and receiving energy for driving the capsule without wires. We used two wavelengths of LEDs and a photodiode sensitive to the two wavelengths for heartbeat sensor. The arterial oxygen saturation is calculated from the amplitude of the heartbeat signal. We fabricated an FM transmitter whose carrier frequency was 80 MHz. Though the GHz range frequency is generally used in transmission, the attenuation in the human body is large. The size of a common linear antenna is about a quarter of its operating wavelength. We employed a coil-based antenna which can reduce size below the quarter of the wavelength. We fabricated a miniaturized transmitter with the coil-based antenna at lower frequency. Our capsule was driven intermittently. We used a rechargeable battery. When the battery ran down, the battery was charged by wireless using the induced electromotive force. This means that the capsule is capable of monitoring vital signs over the long term. We measured the heartbeat from the middle finger of hand in a water tank as a model of a human body.
NASA Technical Reports Server (NTRS)
Mangieri, Mark
2005-01-01
ARED flight instrumentation software is associated with an overall custom designed resistive exercise system that will be deployed on the International Space Station (ISS). This innovative software application fuses together many diverse and new technologies into a robust and usable package. The software takes advantage of touchscreen user interface technology by providing a graphical user interface on a Windows based tablet PC, meeting a design constraint of keyboard-less interaction with flight crewmembers. The software interacts with modified commercial data acquisition (DAQ) hardware to acquire multiple channels of sensor measurment from the ARED device. This information is recorded on the tablet PC and made available, via International Space Station (ISS) Wireless LAN (WLAN) and telemetry subsystems, to ground based mission medics and trainers for analysis. The software includes a feature to accept electronically encoded prescriptions of exercises that guide crewmembers through a customized regimen of resistive weight training, based on personal analysis. These electronically encoded prescriptions are provided to the crew via ISS WLAN and telemetry subsystems. All personal data is securely associated with an individual crew member, based on a PIN ID mechanism.
A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications
Yin, Ming; Borton, David A.; Aceros, Juan; Patterson, William R.; Nurmikko, Arto V.
2014-01-01
A 100-channel fully implantable wireless broadband neural recording system was developed. It features 100 parallel broadband (0.1 Hz–7.8 kHz) neural recording channels, a medical grade 200 mAh Li-ion battery recharged inductively at 150 kHz, and data telemetry using 3.2 GHz to 3.8 GHz FSK modulated wireless link for 48 Mbps Manchester encoded data. All active electronics are hermetically sealed in a titanium enclosure with a sapphire window for electromagnetic transparency. A custom, high-density configuration of 100 individual hermetic feedthrough pins enable connection to an intracortical neural recording microelectrode array. A 100 MHz bandwidth custom receiver was built to remotely receive the FSK signal and achieved −77.7 dBm sensitivity with 10−8 BER at 48 Mbps data rate. ESD testing on all the electronic inputs and outputs has proven that the implantable device satisfies the HBM Class-1B ESD Standard. In addition, the evaluation of the worst-case charge density delivered to the tissue from each I/O pin verifies the patient safety of the device in the event of failure. Finally, the functionality and reliability of the complete device has been tested on-bench and further validated chronically in ongoing freely moving swine and monkey animal trials for more than one year to date. PMID:23853294
NASA Technical Reports Server (NTRS)
2008-01-01
Topics covered inclde: Deployable Wireless Camera Penetrators; Hand-Held Units for Short-Range Wireless Biotelemetry; Wearable Wireless Telemetry System for Implantable BioMEMS Sensors; Electronic Escape Trails for Firefighters; Architecture for a High-to-Medium-Voltage Power Converter; 24-Way Radial Power Combiner/Divider for 31 to 36 GHz; Three-Stage InP Submillimeter-Wave MMIC Amplifier; Fast Electromechanical Switches Based on Carbon Nanotubes; Solid-State High-Temperature Power Cells; Fast Offset Laser Phase-Locking System; Fabricating High-Resolution X-Ray Collimators; Embossed Teflon AF Laminate Membrane Microfluidic Diaphragm Valves; Flipperons for Improved Aerodynamic Performance; System Estimates Radius of Curvature of a Segmented Mirror; Refractory Ceramic Foams for Novel Applications; Self-Deploying Trusses Containing Shape-Memory Polymers; Fuel-Cell Electrolytes Based on Organosilica Hybrid Proton Conductors; Molecules for Fluorescence Detection of Specific Chemicals; Cell-Detection Technique for Automated Patch Clamping; Redesigned Human Metabolic Simulator; Compact, Highly Stable Ion Atomic Clock; LiGa(OTf)(sub 4) as an Electrolyte Salt for Li-Ion Cells; Compact Dielectric-Rod White-Light Delay Lines; Single-Mode WGM Resonators Fabricated by Diamond Turning; Mitigating Photon Jitter in Optical PPM Communication; MACOS Version 3.31; Fiber-Optic Determination of N2, O2, and Fuel Vapor in the Ullage of Liquid-Fuel Tanks; Spiking Neurons for Analysis of Patterns; Symmetric Phase-Only Filtering in Particle-Image Velocimetry; Efficient Coupler for a Bessel Beam Dispersive Element; and Attitude and Translation Control of a Solar Sail Vehicle.
Recording EEG in immature rats with a novel miniature telemetry system
Zayachkivsky, A.; Lehmkuhle, M. J.; Fisher, J. H.; Ekstrand, J. J.
2013-01-01
Serial EEG recordings from immature rat pups are extremely difficult to obtain but important for analyzing animal models of neonatal seizures and other pediatric neurological conditions as well as normal physiology. In this report, we describe the features and applications of a novel miniature telemetry system designed to record EEG in rat pups as young as postnatal day 6 (P6). First, we have recorded electrographic seizure activity in two animal models of neonatal seizures, hypoxia- and kainate-induced seizures at P7. Second, we describe a viable approach for long-term continuous EEG monitoring of naturally reared rat pups implanted with EEG at P6. Third, we have used serial EEG recordings to record age-dependent changes in the background EEG signal as the animals matured from P7 to P11. The important advantages of using miniature wireless EEG technology are: 1) minimally invasive surgical implantation; 2) a device form-factor that is compatible with housing of rat pups with the dam and littermates; 3) serial recordings of EEG activity; and 4) low power consumption of the unit, theoretically allowing continuous monitoring for up to 2 yr without surgical reimplantation. The miniature EEG telemetry system provides a technical advance that allows researchers to record continuous and serial EEG recordings in neonatal rodent models of human neurological disorders, study the progression of the disease, and then assess possible therapies using quantitative EEG as an outcome measure. This new technical approach should improve animal models of human conditions that rely on EEG monitoring for diagnosis and therapy. PMID:23114207
Brown, Kenneth Dewayne [Grain Valley, MO; Dunson, David [Kansas City, MO
2006-08-08
A distributed data transmitter (DTXR) which is an adaptive data communication microwave transmitter having a distributable architecture of modular components, and which incorporates both digital and microwave technology to provide substantial improvements in physical and operational flexibility. The DTXR has application in, for example, remote data acquisition involving the transmission of telemetry data across a wireless link, wherein the DTXR is integrated into and utilizes available space within a system (e.g., a flight vehicle). In a preferred embodiment, the DTXR broadly comprises a plurality of input interfaces; a data modulator; a power amplifier; and a power converter, all of which are modularly separate and distinct so as to be substantially independently physically distributable and positionable throughout the system wherever sufficient space is available.
Brown, Kenneth Dewayne [Grain Valley, MO; Dunson, David [Kansas City, MO
2008-06-03
A distributed data transmitter (DTXR) which is an adaptive data communication microwave transmitter having a distributable architecture of modular components, and which incorporates both digital and microwave technology to provide substantial improvements in physical and operational flexibility. The DTXR has application in, for example, remote data acquisition involving the transmission of telemetry data across a wireless link, wherein the DTXR is integrated into and utilizes available space within a system (e.g., a flight vehicle). In a preferred embodiment, the DTXR broadly comprises a plurality of input interfaces; a data modulator; a power amplifier; and a power converter, all of which are modularly separate and distinct so as to be substantially independently physically distributable and positionable throughout the system wherever sufficient space is available.
Description of the dynamic infrared background/target simulator (DIBS)
NASA Astrophysics Data System (ADS)
Lujan, Ignacio
1988-01-01
The purpose of the Dynamic Infrared Background/Target Simulator (DIBS) is to project dynamic infrared scenes to a test sensor; e.g., a missile seeker that is sensitive to infrared energy. The projected scene will include target(s) and background. This system was designed to present flicker-free infrared scenes in the 8 micron to 12 micron wavelength region. The major subassemblies of the DIBS are the laser write system (LWS), vanadium dioxide modulator assembly, scene data buffer (SDB), and the optical image translator (OIT). This paper describes the overall concept and design of the infrared scene projector followed by some details of the LWS and VO2 modulator. Also presented are brief descriptions of the SDB and OIT.
Biological and Chemical Technologies Research at OIT: Annual Summary Report, FY 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, G.
1998-03-01
The annual summary report presents the fiscal year (FY) 1 997 research activities and accomplishments for the United States Department of Energy (DOE) Biological and Chemical Technologies Research (BCTR) Program. This BCTR program resides within the Office of Industrial Technologies (OIT) of the Office of Energy Efficiency and Renewable Energy (EE). The annual summary report for 1997 (ASR 97) contains the following: program description (including BCTR program mission statement, historical background, relevance, goals and objectives); program structure and organization; selected technical and programmatic highlights for 1 997; detailed descriptions of individual projects; and a listing of program output, including amore » bibliography of published work, patents, and awards arising from work supported by the program.« less
A miniature bidirectional telemetry system for in vivo gastric slow wave recordings.
Farajidavar, Aydin; O'Grady, Gregory; Rao, Smitha M N; Cheng, Leo K; Abell, Thomas; Chiao, J-C
2012-06-01
Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical userinter face. The front-end module conditions the analogue signals, then digitizes and loads the data into a radio for transmission. Data receipt at the backend is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35 × 35 × 27 mm3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124 h operation when utilizing a 560 mAh, 3 V battery. In vivo,slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles min−1), automated activation time detection was modestly better for the wireless system (5% versus 14% FP rate), and signal amplitudes were modestly higher via the wireless system (462 versus 3 86μV; p<0.001). This telemetric system for slow wave acquisition is reliable,power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients.0967-3334/
A miniature bidirectional telemetry system for in-vivo gastric slow wave recordings
Farajidavar, Aydin; O’Grady, Gregory; Rao, Smitha M.N.; Cheng, Leo K; Abell, Thomas; Chiao, J.-C.
2012-01-01
Stomach contractions are initiated and coordinated by an underlying electrical activity (slow waves), and electrical dysrhythmias accompany motility diseases. Electrical recordings taken directly from the stomach provide the most valuable data, but face technical constraints. Serosal or mucosal electrodes have cables that traverse the abdominal wall, or a natural orifice, causing discomfort and possible infection, and restricting mobility. These problems motivated the development of a wireless system. The bidirectional telemetric system constitutes a front-end transponder, a back-end receiver and a graphical user interface. The front-end module conditions the analog signals, then digitizes and loads the data into a radio for transmission. Data receipt at the back-end is acknowledged via a transceiver function. The system was validated in a bench-top study, then validated in-vivo using serosal electrodes connected simultaneously to a commercial wired system. The front-end module was 35×35×27 mm3 and weighed 20 g. Bench-top tests demonstrated reliable communication within a distance range of 30 m, power consumption of 13.5 mW, and 124-hour operation when utilizing a 560-mAh, 3-V battery. In-vivo, slow wave frequencies were recorded identically with the wireless and wired reference systems (2.4 cycles/min), automated activation time detection was modestly better for the wireless system (5% vs 14% false positive rate), and signal amplitudes were modestly higher via the wireless system (462 vs 386 μV; p<0.001). This telemetric system for slow wave acquisition is reliable, power efficient, readily portable and potentially implantable. The device will enable chronic monitoring and evaluation of slow wave patterns in animals and patients. PMID:22635054
Progress In Developing An In-Pile Acoustically Telemetered Sensor Infrastructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, James A.; Garrett, Steven L.; Heibel, Michael D.
2016-09-01
A salient grand challenge for a number of Department of Energy programs such as Fuels Cycle Research and Development ( includes Accident Tolerant Fuel research and the Transient Reactor Test Facility Restart experiments), Light Water Sustainability, and Advanced Reactor Technologies is to enhance our fundamental understanding of fuel and materials behavior under irradiation. Robust and accurate in-pile measurements will be instrumental to develop and validate a computationally predictive multi-scale understanding of nuclear fuel and materials. This sensing technology will enable the linking of fundamental micro-structural evolution mechanisms to the macroscopic degradation of fuels and materials. The in situ sensors andmore » measurement systems will monitor local environmental parameters as well as characterize microstructure evolution during irradiation. One of the major road blocks in developing practical robust, and cost effective in-pile sensor systems, are instrument leads. If a wireless telemetry infrastructure can be developed for in-pile use, in-core measurements would become more attractive and effective. Thus to be successful in accomplishing effective in-pile sensing and microstructure characterization an interdisciplinary measurement infrastructure needs to be developed in parallel with key sensing technology. For the discussion in this research, infrastructure is defined as systems, technology, techniques, and algorithms that may be necessary in the delivery of beneficial and robust data from in-pile devices. The architecture of a system’s infrastructure determines how well it operates and how flexible it is to meet future requirements. The limiting path for the effective deployment of the salient sensing technology will not be the sensors themselves but the infrastructure that is necessary to communicate data from in-pile to the outside world in a non-intrusive and reliable manner. This article gives a high level overview of a promising telemetry infrastructure based on acoustic wireless transmission of data that is being developed and tested by the INL, Penn State and Westinghouse.« less
New routes of allergen immunotherapy.
Aricigil, Mitat; Muluk, Nuray Bayar; Sakarya, Engin Umut; Sakalar, Emine Güven; Senturk, Mehmet; Reisacher, William R; Cingi, Cemal
2016-11-01
Allergen immunotherapy is the only cure for immunoglobulin E mediated type I respiratory allergies. Subcutaneous immunotherapy (SCIT) and sublingual immunotherapy (SLIT) are the most common treatments. In this article, we reviewed new routes of allergen immunotherapy. Data on alternative routes to allow intralymphatic immunotherapy (ILIT), epicutaneous immunotherapy (EPIT), local nasal immunotherapy (LNIT), oral immunotherapy (OIT), and oral mucosal immunotherapy (OMIT) were gathered from the literature and were discussed. ILIT features direct injection of allergens into lymph nodes. ILIT may be clinically effective after only a few injections and induces allergen-specific immunoglobulin G, similarly to SCIT. A limitation of ILIT is that intralymphatic injections are required. EPIT features allergen administration by using patches mounted on the skin. EPIT seeks to target epidermal antigen-presenting Langerhans cells rather than mast cells or the vasculature; this should reduce both local and systemic adverse effects. LNIT involves the spraying of allergen extracts into the nasal cavity. Natural or chemically modified allergens (the latter, termed allergoids, lack immunoglobulin E reactivity) are prepared in a soluble form. OIT involves the regular administration of small amounts of a food allergen by mouth and commences with low oral doses, which are then increased as tolerance develops. OMIT seeks to deliver allergenic proteins to an expanded population of Langerhans cells in the mucosa of the oral cavity. ILIT, EPIT, LNIT, OIT, and OMIT are new routes for allergen immunotherapy. They are safe and effective.
Geothermal Power Generation Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd, Tonya
2013-12-01
Oregon Institute of Technology (OIT) drilled a deep geothermal well on campus (to 5,300 feet deep) which produced 196°F resource as part of the 2008 OIT Congressionally Directed Project. OIT will construct a geothermal power plant (estimated at 1.75 MWe gross output). The plant would provide 50 to 75 percent of the electricity demand on campus. Technical support for construction and operations will be provided by OIT’s Geo-Heat Center. The power plant will be housed adjacent to the existing heat exchange building on the south east corner of campus near the existing geothermal production wells used for heating campus. Coolingmore » water will be supplied from the nearby cold water wells to a cooling tower or air cooling may be used, depending upon the type of plant selected. Using the flow obtained from the deep well, not only can energy be generated from the power plant, but the “waste” water will also be used to supplement space heating on campus. A pipeline will be construction from the well to the heat exchanger building, and then a discharge line will be construction around the east and north side of campus for anticipated use of the “waste” water by facilities in an adjacent sustainable energy park. An injection well will need to be drilled to handle the flow, as the campus existing injection wells are limited in capacity.« less
Advanced Industrial Materials (AIM) Program annual progress report, FY 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-05-01
The Advanced Industrial Materials (AIM) Program is a part of the Office of Industrial Technologies (OIT), Energy Efficiency and Renewable Energy, US Department of Energy (DOE). The mission of AIM is to support development and commercialization of new or improved materials to improve energy efficiency, productivity, product quality, and reduced waste in the major process industries. OIT has embarked on a fundamentally new way of working with industries--the Industries of the Future (IOF) strategy--concentrating on the major process industries that consume about 90% of the energy and generate about 90% of the waste in the industrial sector. These are themore » aluminum, chemical, forest products, glass, metalcasting, and steel industries. OIT has encouraged and assisted these industries in developing visions of what they will be like 20 or 30 years into the future, defining the drivers, technology needs, and barriers to realization of their visions. These visions provide a framework for development of technology roadmaps and implementation plans, some of which have been completed. The AIM Program supports IOF by conducting research and development on materials to solve problems identified in the roadmaps. This is done by National Laboratory/industry/university teams with the facilities and expertise needed to develop new and improved materials. Each project in the AIM Program has active industrial participation and support.« less
Li, Jing; Pan, Qunwan; Zhu, Zaiman; Li, Min; Bai, Yu; Yu, Ran
2015-05-01
To investigate the changes of telemetry electrical activity in the infralimbic cortex (IL) of morphine-dependent rats with extinguished drug-seeking behavior. SD rats were randomly divided into model group and control group and received operations of brain stereotaxic electrode embedding in the IL. The rats in the model group were induced to acquire morphine dependence and then received subsequent extinction training, and the changes of electrical activity in the IL were recorded with a physical wireless telemetry system. In rats with morphine dependence, the time staying in the white box was significantly longer on days 1 and 2 after withdrawal than that before morphine injection and that of the control rats, but was obviously reduced on days 1 and 2 after extinction training to the control level. Compared with the control group, the morphine-dependent rats on day 2 following withdrawal showed significantly increased β wave and decreased δ wave when they stayed in the white box but significantly increased δ wave and decreased α wave and β wave when they shuttled from the black to the white box. On day 2 of extinction, the model rats, when staying in the white box, showed significantly decreased θ wave compared with that of the control rats group but decreased β wave and θ wave and increased δ wave compared with those in the withdrawal period. When they shuttled from black to white box, the model rats showed decreased δ wave and increased α wave and β wave compared with those in the withdrawal period. Morphine-dependent rats have abnormal changes of electrical activity in the IL in drug-seeking extinction to affect their drug-seeking motive and inhibit the expression and maintenance of drug-seeking behaviors.
Immunotherapy (oral and sublingual) for food allergy to fruits.
Yepes-Nuñez, Juan Jose; Zhang, Yuan; Roqué i Figuls, Marta; Bartra Tomas, Joan; Reyes, Juan Manuel; Pineda de la Losa, Fernando; Enrique, Ernesto
2015-11-09
Food allergy is an abnormal immunological response following exposure (usually ingestion) to a food. Elimination of the allergen is the principle treatment for food allergy, including allergy to fruit. Accidental ingestion of allergenic foods can result in severe anaphylactic reactions. Allergen-specific immunotherapy (SIT) is a specific treatment, when the avoidance of allergenic foods is problematic. Recently, studies have been conducted on different types of immunotherapy for the treatment of food allergy, including oral (OIT) and sublingual immunotherapy (SLIT). To determine the efficacy and safety of oral and sublingual immunotherapy in children and adults with food allergy to fruits, when compared with placebo or an elimination strategy. The Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, CINAHL, and AMED were searched for published results along with trial registries and the Journal of Negative Results in BioMedicine for grey literature. The date of the most recent search was July 2015. Randomised controlled trials (RCTs) comparing OIT or SLIT with placebo or an elimination diet were included. Participants were children or adults diagnosed with food allergy who presented immediate fruit reactions. We used standard methodological procedures expected by the Cochrane Collaboration. We assessed treatment effect through risk ratios (RRs) for dichotomous outcomes. We identified two RCTs (N=89) eligible for inclusion. These RCTs addressed oral or sublingual immunotherapy, both in adults, with an allergy to apple or peach respectively. Both studies enrolled a small number of participants and used different methods to provide these differing types of immunotherapy. Both studies were judged to be at high risk of bias in at least one domain. Overall, the quality of evidence was judged to be very low due to the small number of studies and participants and possible bias. The studies were clinically heterogeneous and hence we did not pool the results. A study comparing SLIT with placebo for allergy to peach did not detect a significant difference between the number of patients desensitised at six months following a double-blind placebo-controlled food challenge (RR 1.16, 95% confidence interval (CI) 0.49 to 2.74). The second study, comparing OIT versus no treatment for apple allergy, found an effect on desensitisation in favour of the intervention using an oral provocation test at eight months, but results were imprecise (RR 17.50, 95% CI 1.13 to 270.19). Neither study reported data on evidence of immunologic tolerance. In both studies, the incidence of mild and moderate adverse events was higher in the intervention groups than in the controls. In the study comparing SLIT with placebo, patients in the intervention group experienced significantly more local adverse reactions than participants in the control group (RR 3.21, 95% CI 1.51 to 6.82), though there was not a significant difference in the number of participants experiencing systemic adverse reactions (RR 0.81, 95% CI 0.22 to 3.02). In the study of OIT, two of the 25 participants in the intervention group reported relevant side effects, whereas no participants in the control group reported relevant side effects. There is insufficient evidence for using OIT or SLIT to treat allergy to fruit, specifically related to peach and apple. Mild or moderate adverse reactions were reported more frequently in people receiving OIT or SLIT. However, these reactions could be treated successfully with medications.
Kneisz, Lukas; Unger, Ewald; Lanmüller, Hermann; Mayr, Winfried
2015-10-01
Multichannel bio-signal recording in undisturbed in vivo conditions is a frequent demand in experimental work for development of methodology and associated equipment for functional electrical stimulation (FES) application, limb prosthesis, and diagnostic tools in contemporary rehabilitation efforts. Intramuscular electromyogram (EMG) recordings can provide comprehensive insight in complex interactions of agonistic and antagonistic muscles during movement tasks and in contrast act as reliable control signals for both neuroprosthesis and mechanical prosthesis. We fabricated a fully implantable device, which is capable of recording electromyography signals from inside a body and transmit these signals wirelessly to an external receiver. The developed analog front end uses only two electrodes per channel, provides a gain of 60 dB, and incorporates a band pass filter with lower cut-off frequency of 4 Hz and upper cut-off frequency of 480 Hz. The bidirectional wireless data link, which operates in the 2.4 GHz Industrial, Scientific and Medical band, is designed for transmission distances of 10 m using an application data rate of 1 kSps for each of the two channels. Performed in vitro tests with the devices coated in epoxy resin and inserted into a phantom with tissue-equivalent characteristics confirmed the functionality of our concept and the measurement results are consistent with those from preceding simulations. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Sub-bandage sensing system for remote monitoring of chronic wounds in healthcare
NASA Astrophysics Data System (ADS)
Hariz, Alex; Mehmood, Nasir; Voelcker, Nico
2015-12-01
Chronic wounds, such as venous leg ulcers, can be monitored non-invasively by using modern sensing devices and wireless technologies. The development of such wireless diagnostic tools may improve chronic wound management by providing evidence on efficacy of treatments being provided. In this paper we present a low-power portable telemetric system for wound condition sensing and monitoring. The system aims at measuring and transmitting real-time information of wound-site temperature, sub-bandage pressure and moisture level from within the wound dressing. The system comprises commercially available non-invasive temperature, moisture, and pressure sensors, which are interfaced with a telemetry device on a flexible 0.15 mm thick printed circuit material, making up a lightweight biocompatible sensing device. The real-time data obtained is transmitted wirelessly to a portable receiver which displays the measured values. The performance of the whole telemetric sensing system is validated on a mannequin leg using commercial compression bandages and dressings. A number of trials on a healthy human volunteer are performed where treatment conditions were emulated using various compression bandage configurations. A reliable and repeatable performance of the system is achieved under compression bandage and with minimal discomfort to the volunteer. The system is capable of reporting instantaneous changes in bandage pressure, moisture level and local temperature at wound site with average measurement resolutions of 0.5 mmHg, 3.0 %RH, and 0.2 °C respectively. Effective range of data transmission is 4-5 m in an open environment.
Arduino Based Weather Monitoring Telemetry System Using NRF24L01+
NASA Astrophysics Data System (ADS)
Sidqi, Rafi; Rio Rynaldo, Bagus; Hadi Suroso, Satya; Firmansyah, Rifqi
2018-04-01
Abstract-Weather is an important part of the natural environment, thus knowing weather information is needed before doing activity. The main purpose of this research was to develop a weather monitoring system which capable to transmit weather data via radio frequency by using nRF24L01+ 2,4GHz radio module. This research implement Arduino UNO as the main controller of the system which send data wirelessly using the radio module and received by a receiver system. Received data then logged and displayed using a Graphical User Interface on a personal computer. Test and experiment result show that the system was able to transmit weather data via radio wave with maximum transmitting range of 32 meters.
Function of an Implanted Tissue Glucose Sensor for More than One Year in Animals
Gough, David A.; Kumosa, Lucas S.; Routh, Timothy L.; Lin, Joe T.; Lucisano, Joseph Y.
2015-01-01
An implantable sensor capable of long-term monitoring of tissue glucose concentrations by wireless telemetry has been developed for eventual application in people with diabetes. In a recent trial, the sensor-telemetry system functioned continuously while implanted in subcutaneous tissues of two pigs for a total of 222 days and 520 days respectively, with each animal in both non-diabetic and diabetic states. The sensor detects glucose via an enzyme electrode principle that is based on differential electrochemical oxygen detection, which reduces the sensitivity of the sensor to encapsulation by the body, variations in local microvascular perfusion, limited availability of tissue oxygen, and inactivation of the enzymes. After an initial two-week stabilization period, the implanted sensors maintained stability of calibration for extended periods. The lag between blood and tissue glucose concentrations was 11.8 ± 5.7 minutes and 6.5 ± 13.3 minutes respectively, for rising and falling blood glucose challenges (mean ± SD). The lag was determined mainly by glucose mass transfer in the tissues, rather than the intrinsic response of the sensor, and showed no systematic change over implant test periods. These results represent a milestone in the translation of the sensor system to human applications. PMID:20668297
Pellerin, Laurence; Jenks, Jennifer Anne; Chinthrajah, Sharon; Dominguez, Tina; Block, Whitney; Zhou, Xiaoying; Noshirvan, Arram; Gregori, Silvia; Roncarolo, Maria Grazia; Nadeau, Kari Christine; Bacchetta, Rosa
2018-01-01
Peanut allergy (PA) is a life-threatening condition that lacks regulator-approved treatment. Regulatory T type 1 (T R 1) cells are potent suppressors of immune responses and can be induced in vivo upon repeated antigen exposure or in vitro by using tolerogenic dendritic cells. Whether oral immunotherapy (OIT) leads to antigen-specific T R 1 cell induction has not been established. We sought to determine whether peanut-specific T R 1 cells can be generated in vitro from peripheral blood of patients with PA at baseline or during OIT and whether they are functional compared with peanut-specific T R 1 cells induced from healthy control (HC) subjects. Tolerogenic dendritic cells were differentiated in the presence of IL-10 from PBMCs of patients with PA and HC subjects pulsed with the main peanut allergens of Arachis hypogaea, Ara h 1 and 2, and used as antigen-presenting cells for autologous CD4 + T cells (CD4 + T cells coincubated with tolerogenic dendritic cells pulsed with the main peanut allergens [pea-T10 cells]). Pea-T10 cells were characterized by the presence of CD49b + lymphocyte-activation gene 3 (LAG3) + T R 1 cells, antigen-specific proliferative responses, and cytokine production. CD49b + LAG3 + T R 1 cells were induced in pea-T10 cells at comparable percentages from HC subjects and patients with PA. Despite their antigen specificity, pea-T10 cells of patients with PA with or without OIT, as compared with those of HC subjects, were not anergic and had high T H 2 cytokine production upon peanut-specific restimulation. Peanut-specific T R 1 cells can be induced from HC subjects and patients with PA, but those from patients with PA are functionally defective independent of OIT. The unfavorable T R 1/T H 2 ratio is discussed as a possible cause of PA T R 1 cell impairment. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Noninvasive biosensor and wireless interrogating system for glucose in blood
NASA Astrophysics Data System (ADS)
Varadan, Vijay K.; Whitchurch, Ashwin K.; Sarukesi, K.
2003-07-01
Hypoglycemia-abnormal decrease in blood sugar-is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chirality of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin. It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or a laptop computer.
NASA Technical Reports Server (NTRS)
Liszka, Kathy J.; Mackin, Michael A.; Liehter, Michael J.; York, David W.; Pillai, Dilip; Rosenbaum, David S.
2005-01-01
Feel the relief of a patient suffering from heart arrhythmia, who is able to return home while having her heart monitored by health professionals 24 hours a day, without the fear that she will miss an important indicator and suffer a fatal heart attack - using technology originally developed to conduct experiments on the Space Shuttle. Approximately 400,000 Americans die every year from sudden heart attacks . Medical research revealed that patterns of electrical activity in the heart can act as predictors of these lethal cardiac events known as arrhythmias. Fortunately, certain arrhythmias such as ventricular fibrillation (loss of regular heartbeat and subsequent loss of function) and ventricular tachycardia (rapid heartbeats), can be detected and appropriately treated. Today, patients at moderate risk of arrhythmias can benefit from technology that would permit long- term continuous monitoring of electrical cardiac rhythms outside the hospital environment in the comfort of their own homes. Medical telemetry systems, also known as telemedicine, are evolving rapidly as wireless communication technology advances, evidenced by the commercial products and research prototypes for remote health monitoring that have appeared in recent years. Wireless systems allow patients to move freely in their home and work environment while being monitored remotely by health care professionals.
Takahata, Kenichi; Gianchandani, Yogesh B.
2008-01-01
This paper reports a micromachined capacitive pressure sensor intended for applications that require mechanical robustness. The device is constructed with two micromachined metal plates and an intermediate polymer layer that is soft enough to deform in a target pressure range. The plates are formed of micromachined stainless steel fabricated by batch-compatible micro-electro-discharge machining. A polyurethane room-temperature-vulcanizing liquid rubber of 38-μm thickness is used as the deformable material. This structure eliminates both the vacuum cavity and the associated lead transfer challenges common to micromachined capacitive pressure sensors. For frequency-based interrogation of the capacitance, passive inductor-capacitor tanks are fabricated by combining the capacitive sensor with an inductive coil. The coil has 40 turns of a 127-μm-diameter copper wire. Wireless sensing is demonstrated in liquid by monitoring the variation in the resonant frequency of the tank via an external coil that is magnetically coupled with the tank. The sensitivity at room temperature is measured to be 23-33 ppm/KPa over a dynamic range of 340 KPa, which is shown to match a theoretical estimation. Temperature dependence of the tank is experimentally evaluated. PMID:27879824
Miniaturized optoelectronic system for telemetry of in vivo voltammetric signals.
De Simoni, M G; De Luigi, A; Imeri, L; Algeri, S
1990-08-01
In vivo voltammetry is an electrochemical technique that uses carbon fiber microelectrodes stereotaxically implanted in brain areas to monitor monoamine metabolism and release continuously, in freely moving animals. Electric wires connect the polarograph to the animal. A wire-less transmission system (optoelectronic transmission, OPT) of voltammetric signals is described here. It uses infrared diffused light, exploiting the diffusion of the transmitted light over walls and ceiling towards a receiver. The transmission system consists of a main unit and a satellite unit (40 x 30 x 5 mm) positioned on the animal's back. Voltammetric recordings obtained by the classical system (with wires) and by OPT are well defined and almost identical in shape. The power supply is provided by two thin lithium batteries (+/- 3V) that can record for up to 20 h. OPT permits detailed behavioral observations since the animal can be left free to move in a spacious environment. Voltammetry using OPT allows simultaneous recording of neuronal firing activity as well as electroencephalographic recordings (EEG) since there is no cross-talk between the circuits used. The results illustrate the reliability and usefulness of this wire-less transmission system for studying relationships between neurochemical, behavioral and electrophysiological activities.
Evaluation of a closed loop inductive power transmission system on an awake behaving animal subject.
Kiani, Mehdi; Kwon, Ki Yong; Zhang, Fei; Oweiss, Karim; Ghovanloo, Maysam
2011-01-01
This paper presents in vivo experimental results for a closed loop wireless power transmission system to implantable devices on an awake behaving animal subject. In this system, wireless power transmission takes place across an inductive link, controlled by a commercial off-the-shelf (COTS) radio frequency identification (RFID) transceiver (TRF7960) operating at 13.56 MHz. Induced voltage on the implantable secondary coil is rectified, digitized by a 10-bit analog to digital converter, and transmitted back to the primary via back telemetry. Transmitter (Tx) and receiver (Rx) circuitry were mounted on the back of an adult rat with a nominal distance of ~7 mm between their coils. Our experiments showed that the closed loop system was able to maintain the Rx supply voltage at the designated 3.8 V despite changes in the coils' relative distance and alignment due to animal movements. The Tx power consumption changed between 410 ~ 560 mW in order to deliver 27 mW to the receiver. The open loop system, on the other hand, showed undesired changes in the Rx supply voltage while the Tx power consumption was constant at 660 mW.
NASA Astrophysics Data System (ADS)
Chang, Horng-jinh; Wang, Whe-min
2017-06-01
Taiwan's economic strength has changed drastically in the past decade because of political and economic reasons; however, in order to cope with international environment, higher education must increase its breakthrough to meet the needs of enterprises. School curriculum also has to be timely changes and adjustments. This study will analyze school learning in several directions, use questionnaire to investigate students' learning stress, to find out where students' pressure lie. Also, outsourcing employers' satisfaction survey to find out what do enterprises wants to solve with the drop problem between school and enterprise. Taking Oriental Institute of Technology (OIT) as an example; over the past ten years, OIT has used overseas internships to help students overcome learning difficulties. Overseas practice courses include Penang Malaysia and Suzhou China had gained tremendous breakthrough.
Brayton-cycle solvent recovery heat pump. A technical brief
NASA Astrophysics Data System (ADS)
1994-11-01
The US Department of Energy's (DOE's) Office of Industrial Technologies (OIT) sponsors research and development (R & D) to improve the energy efficiency of American industry and to provide for fuel flexibility. Working closely with industry, OIT has successfully developed more than 50 new technologies that saved industry approximately 80 trillion Btu (84 quadrillion joules) of energy in 1992. More than 200 other projects are in various stages of development from laboratory research to field tests. The use of solvents in the industrial sector is widespread and results in the emission of volatile organic compounds (VOC's) to the atmosphere. These VOC emissions represent an economic loss to industry and contribute significantly to air pollution. To comply with increasingly strict environmental regulations while keeping costs down, industry must find efficient and cost-effective ways to control emissions from solvent use.
New developments in allergen immunotherapy.
Vadlamudi, Anusha; Shaker, Marcus
2015-10-01
Allergic rhinitis, conjunctivitis, and asthma impact quality of life and cost billions of dollars in lost wages, productivity, and medical expenditures. Allergen immunotherapy is the only therapy that alters the allergen immune response, resulting in fewer symptoms upon natural exposure. This review summarizes recent immunotherapy developments. Subcutaneous immunotherapy (SCIT) remains a disease modifying treatment for allergic rhinoconjunctivitis and asthma with rare complications of therapy. Recent evidence suggests that SCIT may be effective in select cases of atopic dermatitis, particularly for patients with dust mite sensitivity. Sublingual immunotherapy (SLIT) tablets are now commercially available for grass and ragweed allergy and appear to have a superior safety profile to SCIT with similar long-term effectiveness, because as with SCIT, symptom improvement persists after the SLIT course is completed. SLIT tablets are administered daily at home (after initial supervised dosing) and may be used shortly before and during the target pollen seasons in a precoseasonal fashion (instead of perennial dosing). Research continues into experimental approaches using oral food allergen immunotherapy (OIT) to modify the natural history of food allergies. Although a proportion of patients in OIT trials experience sustained unresponsiveness, many do not and current recommendations limit the use of OIT to research protocols. Patients have new well tolerated and effective options for more convenient treatment of asthma and allergic rhinoconjunctivitis associated with grass and ragweed allergy. SCIT remains effective for polysensitized patients and may be an option for some patients with atopic dermatitis. Research continues into novel food allergy treatments.
A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry
Liu, Dake; Li, Min
2017-01-01
When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10−7, even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling. PMID:28767090
A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry.
Gong, Chen; Liu, Dake; Miao, Zhidong; Li, Min
2017-08-02
When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10 - 7 , even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.
Pride and physical activity: behavioural regulations as a motivational mechanism?
Mack, Diane E; Kouali, Despina; Gilchrist, Jenna D; Sabiston, Catherine M
2015-01-01
The purpose of this study was to examine the association between fitness-related pride and moderate-to-vigorous physical activity (MVPA). A secondary aim was to examine behavioural regulations consistent with organismic integration theory (OIT) as potential mechanisms of the pride-MVPA relationship. This study used a cross-sectional design. Young adults (N = 465; Mage = 20.55; SDage = 1.75 years) completed self-report instruments of fitness-related pride, motivation and MVPA. Both authentic and hubristic fitness-related pride demonstrated a moderate positive relationship with MVPA, as well as positive associations to more autonomous regulations. Behavioural regulations mediated the relationship between both facets of pride and MVPA with specific indirect effects noted for identified regulation and intrinsic motivation. Overall, these findings demonstrate the association between experiencing fitness-related pride and increased engagement in MVPA. The tenability of OIT was also demonstrated for offering insight into explaining the association between pride and physical activity engagement.
Life-assessment technique for nuclear power plant cables
NASA Astrophysics Data System (ADS)
Bartoníček, B.; Hnát, V.; Plaček, V.
1998-06-01
The condition of polymer-based cable material can be best characterized by measuring elongation at break of its insulating materials. However, it is not often possible to take sufficiently large samples for measurement with the tensile testing machine. The problem has been conveniently solved by utilizing differential scanning calorimetry technique. From the tested cable, several microsamples are taken and the oxidation induction time (OIT) is determined. For each cable which is subject to the assessment of the lifetime, the correlation of OIT with elongation at break and the correlation of elongation at break with the cable service time has to be performed. A reliable assessment of the cable lifetime depends on accuracy of these correlations. Consequently, synergistic effects well known at this time - dose rate effects and effects resulting from the different sequence of applying radiation and elevated temperature must be taken into account.
BCTR: Biological and Chemical Technologies Research 1994 annual summary report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petersen, G.
1995-02-01
The annual summary report presents the fiscal year (FY) 1994 research activities and accomplishments for the United States Department of Energy (DOE) Biological and Chemical Technologies Research (BCTR) Program of the Advanced Industrial Concepts Division (AICD). This AICD program resides within the Office of Industrial Technologies (OIT) of the Office of Energy Efficiency and Renewable Energy (EE). Although the OIT was reorganized in 1991 and AICD no longer exists, this document reports on efforts conducted under the former structure. The annual summary report for 1994 (ASR 94) contains the following: program description (including BCTR program mission statement, historical background, relevance,more » goals and objectives); program structure and organization, selected technical and programmatic highlights for 1994; detailed descriptions of individual projects; a listing of program output, including a bibliography of published work; patents, and awards arising from work supported by BCTR.« less
Digital seismo-acoustic signal processing aboard a wireless sensor platform
NASA Astrophysics Data System (ADS)
Marcillo, O.; Johnson, J. B.; Lorincz, K.; Werner-Allen, G.; Welsh, M.
2006-12-01
We are developing a low power, low-cost wireless sensor array to conduct real-time signal processing of earthquakes at active volcanoes. The sensor array, which integrates data from both seismic and acoustic sensors, is based on Moteiv TMote Sky wireless sensor nodes (www.moteiv.com). The nodes feature a Texas Instruments MSP430 microcontroller, 48 Kbytes of program memory, 10 Kbytes of static RAM, 1 Mbyte of external flash memory, and a 2.4-GHz Chipcon CC2420 IEEE 802.15.4 radio. The TMote Sky is programmed in TinyOS. Basic signal processing occurs on an array of three peripheral sensor nodes. These nodes are tied into a dedicated GPS receiver node, which is focused on time synchronization, and a central communications node, which handles data integration and additional processing. The sensor nodes incorporate dual 12-bit digitizers sampling a seismic sensor and a pressure transducer at 100 samples per second. The wireless capabilities of the system allow flexible array geometry, with a maximum aperture of 200m. We have already developed the digital signal processing routines on board the Moteiv Tmote sensor nodes. The developed routines accomplish Real-time Seismic-Amplitude Measurement (RSAM), Seismic Spectral- Amplitude Measurement (SSAM), and a user-configured Short Term Averaging / Long Term Averaging (STA LTA ratio), which is used to calculate first arrivals. The processed data from individual nodes are transmitted back to a central node, where additional processing may be performed. Such processing will include back azimuth determination and other wave field analyses. Future on-board signal processing will focus on event characterization utilizing pattern recognition and spectral characterization. The processed data is intended as low bandwidth information which can be transmitted periodically and at low cost through satellite telemetry to a web server. The processing is limited by the computational capabilities (RAM, ROM) of the nodes. Nevertheless, we envision this product to be a useful tool for assessing the state of unrest at remote volcanoes.
Deep-brain stimulator and control of Parkinson's disease
NASA Astrophysics Data System (ADS)
Varadan, Vijay K.; Harbaugh, Robert; Abraham, Jose K.
2004-07-01
The design of a novel feedback sensor system with wireless implantable polymer MEMS sensors for detecting and wirelessly transmitting physiological data that can be used for the diagnosis and treatment of various neurological disorders, such as Parkinson's disease, epilepsy, head injury, stroke, hydrocephalus, changes in pressure, patient movements, and tremors is presented in this paper. The sensor system includes MEMS gyroscopes, accelerometers, and pressure sensors. This feedback sensor system focuses on the development and integration of implantable systems with various wireless sensors for medical applications, particularly for the Parkinson's disease. It is easy to integrate and modify the sensor network feed back system for other neurological disorders mentioned above. The monitoring and control of tremor in Parkinson's disease can be simulated on a skeleton via wireless telemetry system communicating with electroactive polymer actuator, and microsensors attached to the skeleton hand and legs. Upon sensing any abnormal motor activity which represent the characteristic rhythmic motion of a typical Parkinson's (PD) patient, these sensors will generate necessary control pulses which will be transmitted to a hat sensor system on the skeleton head. Tiny inductively coupled antennas attached to the hat sensor system can receive these control pulses, demodulate and deliver it to actuate the parts of the skeleton to control the abnormal motor activity. This feedback sensor system can further monitor and control depending on the amplitude of the abnormal motor activity. This microsystem offers cost effective means of monitoring and controlling of neurological disorders in real PD patients. Also, this network system offers a remote monitoring of the patients conditions without visiting doctors office or hospitals. The data can be monitored using PDA and can be accessed using internet (or cell phone). Cellular phone technology will allow a health care worker to be automatically notified if monitoring indicates an emergency situation. The main advantage of such system is that it can effectively monitor large number of patients at the same time, which helps to compensate the present shortage of health care workers.
Aggregate Interview Method of ranking orthopedic applicants predicts future performance.
Geissler, Jacqueline; VanHeest, Ann; Tatman, Penny; Gioe, Terence
2013-07-01
This article evaluates and describes a process of ranking orthopedic applicants using what the authors term the Aggregate Interview Method. The authors hypothesized that higher-ranking applicants using this method at their institution would perform better than those ranked lower using multiple measures of resident performance. A retrospective review of 115 orthopedic residents was performed at the authors' institution. Residents were grouped into 3 categories by matching rank numbers: 1-5, 6-14, and 15 or higher. Each rank group was compared with resident performance as measured by faculty evaluations, the Orthopaedic In-Training Examination (OITE), and American Board of Orthopaedic Surgery (ABOS) test results. Residents ranked 1-5 scored significantly better on patient care, behavior, and overall competence by faculty evaluation (P<.05). Residents ranked 1-5 scored higher on the OITE compared with those ranked 6-14 during postgraduate years 2 and 3 (P⩽.5). Graduates who had been ranked 1-5 had a 100% pass rate on the ABOS part 1 examination on the first attempt. The most favorably ranked residents performed at or above the level of other residents in the program; they did not score inferiorly on any measure. These results support the authors' method of ranking residents. The rigorous Aggregate Interview Method for ranking applicants consistently identified orthopedic resident candidates who scored highly on the Accreditation Council for Graduate Medical Education resident core competencies as measured by faculty evaluations, performed above the national average on the OITE, and passed the ABOS part 1 examination at rates exceeding the national average. Copyright 2013, SLACK Incorporated.
Vermeirssen, Etiënne L M; Campiche, Sophie; Dietschweiler, Conrad; Werner, Inge; Burkhardt, Michael
2018-05-22
To protect house façades from fouling by microorganisms, biocides can be added to a render or paint before it is applied. During driving rain events, these biocides gradually leach out and have the potential to pollute soil or aquatic ecosystems. We studied the leaching behaviour of biocides and toxicity of leachates from renders with either free or encapsulated biocides. Both render types contained equal amounts of terbutryn, 2-octyl-3(2H)-isothiazolinone (OIT) and 4,5-dichloro-2-n-octyl-4-isothiazolino-3-one (DCOIT). Leachate samples were generated over nine immersion cycles according to a European standard and biocides were quantified. The first and ninth samples were tested using bioassays with algae, bacteria and water flea, the first sample with earthworms and springtails. Encapsulation reduced leaching of terbutryn, OIT and DCOIT four-, 17-, and 27-fold. For aquatic organisms, the toxicity of water from render containing encapsulated biocides was always lower than that of render with free biocides. Furthermore, toxicity decreased four- to five-fold over the nine immersion cycles. Inhibition of photosynthesis was the most sensitive endpoint, followed by algal growth rate, bacterial bioluminescence and water flea reproduction. Toxicity to algae was explained by terbutryn and toxicity to bacteria by OIT. None of the samples affected soil organisms. Results demonstrate that combining standardised leaching tests with standardised bioassays is a promising approach to evaluate the ecotoxicity of biocides that leach from façade renders. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Evaluation of a low cost wireless heat ratio method system for measuring transpiration
NASA Astrophysics Data System (ADS)
Eiriksson, D.; Boyer, B.; Aishlin, P. S.; Bowling, D. R.
2016-12-01
For decades, environmental measurements in remote locations have consisted of sensors hard wired to loggers that send data to central servers via radio, satellite, or cellular telemetry. This model of data collection is effective when all sensors are located in close proximity to the central data logger, such as on a weather station. Frequently, however, in order to adequately capture the spatial heterogeneity associated with environmental processes (e.g., transpiration, soil moisture, or snow depth), it is necessary to install many sensors 10's to 100's of meters from a central data logging station. This presents a practical and financial obstacle when considering the cost of cabling and conduit, in addition to the potential data collection and data quality problems associated with long cable runs. We offer a solution to this persistent challenge with a hybrid datalogging system that combines the power and reliability of Campbell Scientific logging and telemetry equipment with low cost Xbee radios and Arduino based data logging platforms. To evaluate the promise of this hybrid datalogging concept we developed a new generation of low cost, homemade heat ratio sapflux sensors and tested them at a forested site in the Wasatch Mountains, near Salt Lake City, Utah. We present data from this test site, heat ratio method sensor construction details, and example code that merges the capabilities of Arduino and Campbell Scientific datalogging systems.
Shuenn-Yuh Lee; Chih-Jen Cheng; Ming-Chun Liang
2011-08-01
In this paper, wireless telemetry using the near-field coupling technique with round-wire coils for an implanted cardiac microstimulator is presented. The proposed system possesses an external powering amplifier and an internal bidirectional microstimulator. The energy of the microstimulator is provided by a rectifier that can efficiently charge a rechargeable device. A fully integrated regulator and a charge pump circuit are included to generate a stable, low-voltage, and high-potential supply voltage, respectively. A miniature digital processor includes a phase-shift-keying (PSK) demodulator to decode the transmission data and a self-protective system controller to operate the entire system. To acquire the cardiac signal, a low-voltage and low-power monitoring analog front end (MAFE) performs immediate threshold detection and data conversion. In addition, the pacing circuit, which consists of a pulse generator (PG) and its digital-to-analog (D/A) controller, is responsible for stimulating heart tissue. The chip was fabricated by Taiwan Semiconductor Manufacturing Company (TSMC) with 0.35-μm complementary metal-oxide semiconductor technology to perform the monitoring and pacing functions with inductively powered communication. Using a model with lead and heart tissue on measurement, a -5-V pulse at a stimulating frequency of 60 beats per minute (bpm) is delivered while only consuming 31.5 μW of power.
A programmable microsystem using system-on-chip for real-time biotelemetry.
Wang, Lei; Johannessen, Erik A; Hammond, Paul A; Cui, Li; Reid, Stuart W J; Cooper, Jonathan M; Cumming, David R S
2005-07-01
A telemetry microsystem, including multiple sensors, integrated instrumentation and a wireless interface has been implemented. We have employed a methodology akin to that for System-on-Chip microelectronics to design an integrated circuit instrument containing several "intellectual property" blocks that will enable convenient reuse of modules in future projects. The present system was optimized for low-power and included mixed-signal sensor circuits, a programmable digital system, a feedback clock control loop and RF circuits integrated on a 5 mm x 5 mm silicon chip using a 0.6 microm, 3.3 V CMOS process. Undesirable signal coupling between circuit components has been investigated and current injection into sensitive instrumentation nodes was minimized by careful floor-planning. The chip, the sensors, a magnetic induction-based transmitter and two silver oxide cells were packaged into a 36 mm x 12 mm capsule format. A base station was built in order to retrieve the data from the microsystem in real-time. The base station was designed to be adaptive and timing tolerant since the microsystem design was simplified to reduce power consumption and size. The telemetry system was found to have a packet error rate of 10(-3) using an asynchronous simplex link. Trials in animal carcasses were carried out to show that the transmitter was as effective as a conventional RF device whilst consuming less power.
ANZA Seismic Network- From Monitoring to Science
NASA Astrophysics Data System (ADS)
Vernon, F.; Eakin, J.; Martynov, V.; Newman, R.; Offield, G.; Hindley, A.; Astiz, L.
2007-05-01
The ANZA Seismic Network (http:eqinfo.ucsd.edu) utilizes broadband and strong motion sensors with 24-bit dataloggers combined with real-time telemetry to monitor local and regional seismicity in southernmost California. The ANZA network provides real-time data to the IRIS DMC, California Integrated Seismic Network (CISN), other regional networks, and the Advanced National Seismic System (ANSS), in addition to providing near real-time information and monitoring to the greater San Diego community. Twelve high dynamic range broadband and strong motion sensors adjacent to the San Jacinto Fault zone contribute data for earthquake source studies and continue the monitoring of the seismic activity of the San Jacinto fault initiated 24 years ago. Five additional stations are located in the San Diego region with one more station on San Clemente Island. The ANZA network uses the advance wireless networking capabilities of the NSF High Performance Wireless Research and Education Network (http:hpwren.ucsd.edu) to provide the communication infrastructure for the real-time telemetry of Anza seismic stations. The ANZA network uses the Antelope data acquisition software. The combination of high quality hardware, communications, and software allow for an annual network uptime in excess of 99.5% with a median annual station real-time data return rate of 99.3%. Approximately 90,000 events, dominantly local sources but including regional and teleseismic events, comprise the ANZA network waveform database. All waveform data and event data are managed using the Datascope relational database. The ANZA network data has been used in a variety of scientific research including detailed structure of the San Jacinto Fault Zone, earthquake source physics, spatial and temporal studies of aftershocks, array studies of teleseismic body waves, and array studies on the source of microseisms. To augment the location, detection, and high frequency observations of the seismic source spectrum from local earthquakes, the ANZA network is receiving real-time data from borehole arrays located at the UCSD Thornton Hospital, and from UCSB's Borrego Valley and Garner Valley Downhole Arrays. Finally the ANZA network is acquiring data from seven PBO sites each with 300 meter deep MEMs accelerometers, passive seismometers, and a borehole strainmeter.
Hampson, Robert E.; Collins, Vernell; Deadwyler, Sam A.
2009-01-01
A new wireless transceiver is described for recording individual neuron firing from behaving rats utilizing Bluetooth transmission technology and a processor onboard for discrimination of neuronal waveforms and associated time stamps. This universal brain activity transmitter (UBAT) is attached to rodents via a backpack and amplifier headstage and can transmit 16 channels of captured neuronal firing data via a Bluetooth transceiver chip over very large and unconstrained distances. The onboard microprocessor of the UBAT allows flexible online control over waveform isolation criteria via transceiver instruction and the two-way communication capacity allows for closed-loop applications between neural events and behavioral or physiological processes which can be modified by transceiver instructions. A detailed description of the multiplexer processing of channel data as well as examples of neuronal recordings in different behavioral testing contexts is provided to demonstrate the capacity for robust transmission within almost any laboratory environment. A major advantage of the UBAT is the long transmission range and lack of object-based line of sight interference afforded by Bluetooth technology, allowing flexible recording capabilities within multiple experimental paradigms without interruption. Continuous recordings over very large distance separations from the monitor station are demonstrated providing experimenters with recording advantages not previously available with other telemetry devices. PMID:19524612
Hampson, Robert E; Collins, Vernell; Deadwyler, Sam A
2009-09-15
A new wireless transceiver is described for recording individual neuron firing from behaving rats utilizing Bluetooth transmission technology and a processor onboard for discrimination of neuronal waveforms and associated time stamps. This universal brain activity transmitter (UBAT) is attached to rodents via a backpack and amplifier headstage and can transmit 16 channels of captured neuronal firing data via a Bluetooth transceiver chip over very large and unconstrained distances. The onboard microprocessor of the UBAT allows flexible online control over waveform isolation criteria via transceiver instruction and the two-way communication capacity allows for closed-loop applications between neural events and behavioral or physiological processes which can be modified by transceiver instructions. A detailed description of the multiplexer processing of channel data as well as examples of neuronal recordings in different behavioral testing contexts is provided to demonstrate the capacity for robust transmission within almost any laboratory environment. A major advantage of the UBAT is the long transmission range and lack of object-based line of sight interference afforded by Bluetooth technology, allowing flexible recording capabilities within multiple experimental paradigms without interruption. Continuous recordings over very large distance separations from the monitor station are demonstrated providing experimenters with recording advantages not previously available with other telemetry devices.
Yang, Chin-Lung; Zheng, Gou-Tsun
2015-11-20
This study proposes using wireless low power thermal sensors for basal-body-temperature detection using frequency modulated telemetry devices. A long-term monitoring sensor requires low-power circuits including a sampling circuit and oscillator. Moreover, temperature compensated technologies are necessary because the modulated frequency might have additional frequency deviations caused by the varying temperature. The temperature compensated oscillator is composed of a ring oscillator and a controlled-steering current source with temperature compensation, so the output frequency of the oscillator does not drift with temperature variations. The chip is fabricated in a standard Taiwan Semiconductor Manufacturing Company (TSMC) 0.18-μm complementary metal oxide semiconductor (CMOS) process, and the chip area is 0.9 mm². The power consumption of the sampling amplifier is 128 µW. The power consumption of the voltage controlled oscillator (VCO) core is less than 40 µW, and the output is -3.04 dBm with a buffer stage. The output voltage of the bandgap reference circuit is 1 V. For temperature measurements, the maximum error is 0.18 °C with a standard deviation of ±0.061 °C, which is superior to the required specification of 0.1 °C.
NASA Technical Reports Server (NTRS)
2003-01-01
Topics covered include: Using Diffusion Bonding in Making Piezoelectric Actuators; Wireless Temperature-Monitoring System; Analog Binaural Circuits for Detecting and Locating Leaks; Mirrors Containing Biomimetic Shape-Control Actuators; Surface-Micromachined Planar Arrays of Thermopiles; Cascade Back-Propagation Learning in Neural Networks; Perovskite Superlattices as Tunable Microwave Devices; Rollable Thin-Shell Nanolaminate Mirrors; Flight Tests of a Ministick Controller in an F/A-18 Airplane; Piezoelectrically Actuated Shutter for High Vacuum; Bio-Inspired Engineering of Exploration Systems; Microscope Cells Containing Multiple Micromachined Wells; Electrophoretic Deposition for Fabricating Microbatteries; Integrated Arrays of Ion-Sensitive Electrodes; Model of Fluidized Bed Containing Reacting Solids and Gases; Membrane Mirrors With Bimorph Shape Actuators; Using Fractional Clock-Period Delays in Telemetry Arraying; Developing Generic Software for Spacecraft Avionics; Numerical Study of Pyrolysis of Biomass in Fluidized Beds; and Assessment of Models of Chemically Reacting Granular Flows.
T-cell epitope-containing hypoallergenic β-lactoglobulin for oral immunotherapy in milk allergy.
Ueno, Hiroshi M; Kato, Teruhiko; Ohnishi, Hidenori; Kawamoto, Norio; Kato, Zenichiro; Kaneko, Hideo; Kondo, Naomi; Nakano, Taku
2016-12-01
Optimally hydrolyzed β-Lactoglobulin (βLg) is a promising milk oral immunotherapy (OIT) candidate with respect to showing reduced B-cell reactivity but retaining the T-cell epitope. To demonstrate that an edible hypoallergenic βLg hydrolysate containing the T-cell epitope is suitable for OIT. We tested how chymotrypsin affected the retention of the T-cell epitope of βLg when preparing βLg hydrolysates using food-grade trypsin. We investigated the effect of chymotrypsin activity on the formation of the T-cell epitope-containing peptide of βLg (βLg 102-124 ) and prepared an edible βLg hydrolysate containing βLg 102-124 using screened food-grade trypsins. B-cell reactivity was determined using immunoassays in which ELISA was performed with anti-βLg rabbit IgG and Western blotting was performed with a milk-specific IgE antiserum. In βLg hydrolysis performed by varying the activity of trypsin and chymotrypsin, chymotrypsin activity inhibited the formation of βLg 102-124 with an increase in hydrolysis time in a dose-dependent manner. βLg 102-124 was generated by two of five food-grade trypsins used at a ratio of 1:50 (w/w, enzyme/substrate) for 20 h at 40°C. The edible βLg hydrolysate retained βLg 102-124 and showed a reduction in molecular weight distribution and antigenicity against IgG and IgE. Chymotrypsin activity inhibited the formation of βLg 102-124 in the trypsin hydrolysate of βLg. This βLg trypsin hydrolysate is a novel candidate for peptide-based OIT in cow's milk allergy for safely inducing desensitization. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
EAACI Guidelines on allergen immunotherapy: IgE-mediated food allergy.
Pajno, G B; Fernandez-Rivas, M; Arasi, S; Roberts, G; Akdis, C A; Alvaro-Lozano, M; Beyer, K; Bindslev-Jensen, C; Burks, W; Ebisawa, M; Eigenmann, P; Knol, E; Nadeau, K C; Poulsen, L K; van Ree, R; Santos, A F; du Toit, G; Dhami, S; Nurmatov, U; Boloh, Y; Makela, M; O'Mahony, L; Papadopoulos, N; Sackesen, C; Agache, I; Angier, E; Halken, S; Jutel, M; Lau, S; Pfaar, O; Ryan, D; Sturm, G; Varga, E-M; van Wijk, R G; Sheikh, A; Muraro, A
2018-04-01
Food allergy can result in considerable morbidity, impairment of quality of life, and healthcare expenditure. There is therefore interest in novel strategies for its treatment, particularly food allergen immunotherapy (FA-AIT) through the oral (OIT), sublingual (SLIT), or epicutaneous (EPIT) routes. This Guideline, prepared by the European Academy of Allergy and Clinical Immunology (EAACI) Task Force on Allergen Immunotherapy for IgE-mediated Food Allergy, aims to provide evidence-based recommendations for active treatment of IgE-mediated food allergy with FA-AIT. Immunotherapy relies on the delivery of gradually increasing doses of specific allergen to increase the threshold of reaction while on therapy (also known as desensitization) and ultimately to achieve post-discontinuation effectiveness (also known as tolerance or sustained unresponsiveness). Oral FA-AIT has most frequently been assessed: here, the allergen is either immediately swallowed (OIT) or held under the tongue for a period of time (SLIT). Overall, trials have found substantial benefit for patients undergoing either OIT or SLIT with respect to efficacy during treatment, particularly for cow's milk, hen's egg, and peanut allergies. A benefit post-discontinuation is also suggested, but not confirmed. Adverse events during FA-AIT have been frequently reported, but few subjects discontinue FA-AIT as a result of these. Taking into account the current evidence, FA-AIT should only be performed in research centers or in clinical centers with an extensive experience in FA-AIT. Patients and their families should be provided with information about the use of FA-AIT for IgE-mediated food allergy to allow them to make an informed decision about the therapy. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.
Syed, Aleena; Garcia, Marco A; Lyu, Shu-Chen; Bucayu, Robert; Kohli, Arunima; Ishida, Satoru; Berglund, Jelena P; Tsai, Mindy; Maecker, Holden; O'Riordan, Gerri; Galli, Stephen J; Nadeau, Kari C
2014-02-01
The mechanisms contributing to clinical immune tolerance remain incompletely understood. This study provides evidence for specific immune mechanisms that are associated with a model of operationally defined clinical tolerance. Our overall objective was to study laboratory changes associated with clinical immune tolerance in antigen-induced T cells, basophils, and antibodies in subjects undergoing oral immunotherapy (OIT) for peanut allergy. In a phase 1 single-site study, we studied participants (n = 23) undergoing peanut OIT and compared them with age-matched allergic control subjects (n = 20) undergoing standard of care (abstaining from peanut) for 24 months. Participants were operationally defined as clinically immune tolerant (IT) if they had no detectable allergic reactions to a peanut oral food challenge after 3 months of therapy withdrawal (IT, n = 7), whereas those who had an allergic reaction were categorized as nontolerant (NT; n = 13). Antibody and basophil activation measurements did not statistically differentiate between NT versus IT participants. However, T-cell function and demethylation of forkhead box protein 3 (FOXP3) CpG sites in antigen-induced regulatory T cells were significantly different between IT versus NT participants. When IT participants were withdrawn from peanut therapy for an additional 3 months (total of 6 months), only 3 participants remained classified as IT participants, and 4 participants regained sensitivity along with increased methylation of FOXP3 CpG sites in antigen-induced regulatory T cells. In summary, modifications at the DNA level of antigen-induced T-cell subsets might be predictive of a state of operationally defined clinical immune tolerance during peanut OIT. Copyright © 2014 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
Arning, Jürgen; Matzke, Marianne; Stolte, Stefan; Nehen, Frauke; Bottin-Weber, Ulrike; Böschen, Andrea; Abdulkarim, Salha; Jastorff, Bernd; Ranke, Johannes
2009-12-01
To demonstrate how baseline toxicity can be separated from other more specific modes of toxic action and to address possible pitfals when dealing with hydrophobic substances, the four isothiazol-3-one biocides N-methylisothiazol-3-one (MIT), 5-chloro-N-methylisothiazol-3-one (CIT), N-octylisothiazol-3-one (OIT), and 4,5-dichloro-N-octylisothiazol-3-one (DCOIT) as an example for reactive electrophilic xenobiotics were tested for their cytotoxic effects on the human hepatoblastoma cell line Hep G2, on the marine bacterium Vibrio fischeri, and on the limnic green alga Scenedesmus vacuolatus. In each of the three test systems, toxic effects were observed in a consistent pattern. The two chlorinated compounds and OIT were found to be significantly more toxic than MIT. As compared to baseline toxicants, the small and polar MIT and CIT exhibited pronounced excess toxicity in each of the three test systems that is presumably triggered by their intrinsic reactivity toward cellular thiols. In contrast, OIT and DCOIT showed mainly toxicities that could be explained by their hydrophobicity. Analyzing and comparing these results using the toxic ratio concept and with data that indicate a dramatic depletion of cellular glutathione levels after incubation with DCOIT reveals that for highly hydrophobic substances, baseline level toxicity in an assay for acute toxicity can lead to an oversight of other more specific modes of toxic action that may cause significant effects that might be less reversible than those caused by unreactive baseline toxicants. This possibility should be taken into account in the hazard assessment of chemicals that are both hydrophobic and reactive.
Mondoulet, Lucie; Dioszeghy, Vincent; Busato, Florence; Plaquet, Camille; Dhelft, Véronique; Bethune, Kevin; Leclere, Laurence; Daviaud, Christian; Ligouis, Mélanie; Sampson, Hugh; Dupont, Christophe; Tost, Jörg
2018-05-19
Epicutaneous immunotherapy (EPIT) is a promising method for treating food allergies. In animal models, EPIT induces sustained unresponsiveness and prevents further sensitization mediated by Tregs. Here, we elucidate the mechanisms underlying the therapeutic effect of EPIT, by characterizing the kinetics of DNA methylation changes in sorted cells from spleen and blood and by evaluating its persistence and bystander effect compared to oral immunotherapy (OIT). BALB/c mice orally sensitized to peanut proteins (PPE) were treated by EPIT using a PPE-patch or by PPE-OIT. Another set of peanut-sensitized mice treated by EPIT or OIT were sacrificed following a protocol of sensitization to OVA. DNA methylation was analysed during immunotherapy and 8 weeks after the end of treatment in sorted cells from spleen and blood by pyrosequencing. Humoral and cellular responses were measured during and after immunotherapy. Analyses showed a significant hypermethylation of the Gata3 promoter detectable only in Th2 cells for EPIT from the 4 th week and a significant hypomethylation of the Foxp3 promoter in CD62L + Tregs, which was sustained only for EPIT. In addition, mice treated with EPIT were protected from subsequent sensitization and maintained the epigenetic signature characteristic for EPIT. Our study demonstrates that EPIT leads to a unique and stable epigenetic signature in specific T cell compartments with down regulation of Th2 key regulators and upregulation of Treg transcription factors, likely explaining the sustainability of protection and the observed bystander effect. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Prevalence of celiac disease in patients with severe food allergy.
Pillon, R; Ziberna, F; Badina, L; Ventura, A; Longo, G; Quaglia, S; De Leo, L; Vatta, S; Martelossi, S; Patano, G; Not, T; Berti, I
2015-10-01
The association between food allergy and celiac disease (CD) is still to be clarified. We screened for CD 319 patients with severe food allergy (IgE > 85 kU/l against food proteins and a history of severe allergic reactions) who underwent specific food oral immunotherapy (OIT), together with 128 children with mild allergy who recovered without OIT, and compared the prevalence data with our historical data regarding healthy schoolchildren. Sixteen patients (5%) with severe allergy and one (0.8%) with mild allergy tested positive for both genetic and serological CD markers, while the prevalence among the schoolchildren was 1%. Intestinal biopsies were obtained in 13/16 patients with severe allergy and in the one with mild allergy, confirming the diagnosis of CD. Sufferers from severe food allergy seem to be at a fivefold increased risk of CD. Our findings suggest that routine screening for CD should be recommended in patients with severe food allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Telemetry methods for monitoring physiological parameters
NASA Technical Reports Server (NTRS)
Fryer, T. B.; Sandler, H.
1982-01-01
The use of telemetry to monitor various physiological functions is discussed. The advantages of the technique and the parameters that it can monitor are assessed, and the main telemetry systems, including pressure telemetry, flow telemetry, and multichannel telemetry, are detailed. Human applications of implanted flow transducers, total implant versus backpack telemetry, the use of power sources and integrated circuits in telemetry, and the future prospects of the technique in hypertension treatment and research are discussed.
78 FR 32417 - Intent To Request Renewal From OMB of One Current Public Collection of Information...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-30
... Officer, Office of Information Technology (OIT), TSA-11, Transportation Security Administration, 601 South... technological collection techniques or other forms of information technology. Information Collection Requirement... provide fingerprints and undergo a criminal history records check. The program implements authorities set...
Telemetry Attributes Transfer Standard (TMATS) Handbook
2015-07-01
Example ......................... 6-1 Appendix A. Extensible Markup Language TMATS Differences ...................................... A-1 Appendix B...return-to-zero - level TG Telemetry Group TM telemetry TMATS Telemetry Attributes Transfer Standard XML eXtensible Markup Language Telemetry... Markup Language) format. The initial version of a standard 1 Range Commanders Council. Telemetry
Experimental Study of Radiation Efficiency from an Ingested Source inside a Human Body Model*.
Chan, Yawen; -H Meng, Max; Wu, K-L; Wang, Xiaona
2005-01-01
The attenuation of human body trunk at frequency range of 100MHz to 6GHz from an internal source was estimated using a simplified experimental model. Antennas were placed in the model which was filled with distilled water, 0.9% NaCl saline solution, and porcine body tissue alternately to determine the attenuation of the system. Saline has greater attenuation than water due to its higher conductivity, while porcine body tissue has attenuation bounded by saline solution and water. Estimated attenuation at the four ISM bands, 434MHz, 915MHz, 2.45GHz and 5.8GHz were given and all of these bands satisfied the safety and sensitivity requirements of a biomedical telemetry system. 915MHz and 2.45GHz are good choices for the wireless link because of their relatively larger electrical size of RF components such as antenna. In addition, with the growth in wireless LAN and Bluetooth technology, miniaturized antennas, camera modules, and other RF devices have been developed which can be employed in biomedical ingested or implanted devices. This paper gives a reference of attenuation values of a human body trunk of average size. It should be noted that the attenuation values can be different for different body size and different body composition, and therefore the values in this paper serves as a reference only.
Printable low-cost sensor systems for healthcare smart textiles
NASA Astrophysics Data System (ADS)
Rai, Pratyush; Kumar, Prashanth S.; Oh, Sechang; Kwon, Hyeokjun; Mathur, Gyanesh N.; Varadan, Vijay K.
2011-04-01
Smart textiles-based wearable health monitoring systems (ST-HMS) have been presented as elegant solutions to the requirements of individuals across a wide range of ages. They can be used to monitor young or elderly recuperating /convalescent patients either in hospital or at home, or they can be used by young athletes to monitor important physiological parameters to better design their training or fitness program. Business and academic interests, all over the world, have fueled a great deal of work in the development of this technology since 1990. However, two important impediments to the development of ST-HMS are:-integration of flexible electrodes, flexible sensors, signal conditioning circuits and data logging or wireless transmission devices into a seamless garment and a means to mass manufacture the same, while keeping the costs low. Roll-to-roll printing and screen printing are two low cost methods for large scale manufacturing on flexible substrates and can be extended to textiles as well. These two methods are, currently, best suited for planar structures. The sensors, integrated with wireless telemetry, facilitate development of a ST-HMS that allows for unobtrusive health monitoring. In this paper, we present our results with planar screen printable sensors based on conductive inks which can be used to monitor EKG, abdominal respiration effort, blood pressure, pulse rate and body temperature. The sensor systems were calibrated, and tested for sensitivity, reliability and robustness to ensure reuse after washing cycles.
Design of a Parachute Canopy Instrumentation Platform
NASA Technical Reports Server (NTRS)
Alshahin, Wahab M.; Daum, Jared S.; Holley, James J.; Litteken, Douglas A.; Vandewalle, Michael T.
2015-01-01
This paper discusses the current technology available to design and develop a reliable and compact instrumentation platform for parachute system data collection and command actuation. Wireless communication with a parachute canopy will be an advancement to the state of the art of parachute design, development, and testing. Embedded instrumentation of the parachute canopy will provide reefing line tension, skirt position data, parachute health monitoring, and other telemetry, further validating computer models and giving engineering insight into parachute dynamics for both Earth and Mars entry that is currently unavailable. This will allow for more robust designs which are more optimally designed in terms of structural loading, less susceptible to adverse dynamics, and may eventually pave the way to currently unattainable advanced concepts of operations. The development of this technology has dual use potential for a variety of other applications including inflatable habitats, aerodynamic decelerators, heat shields, and other high stress environments.
Active Microelectronic Neurosensor Arrays for Implantable Brain Communication Interfaces
Song, Y.-K.; Borton, D. A.; Park, S.; Patterson, W. R.; Bull, C. W.; Laiwalla, F.; Mislow, J.; Simeral, J. D.; Donoghue, J. P.; Nurmikko, A. V.
2010-01-01
We have built a wireless implantable microelectronic device for transmitting cortical signals transcutaneously. The device is aimed at interfacing a microelectrode array cortical to an external computer for neural control applications. Our implantable microsystem enables presently 16-channel broadband neural recording in a non-human primate brain by converting these signals to a digital stream of infrared light pulses for transmission through the skin. The implantable unit employs a flexible polymer substrate onto which we have integrated ultra-low power amplification with analog multiplexing, an analog-to-digital converter, a low power digital controller chip, and infrared telemetry. The scalable 16-channel microsystem can employ any of several modalities of power supply, including via radio frequency by induction, or infrared light via a photovoltaic converter. As of today, the implant has been tested as a sub-chronic unit in non-human primates (~ 1 month), yielding robust spike and broadband neural data on all available channels. PMID:19502132
DOE Office of Scientific and Technical Information (OSTI.GOV)
U.S. Department of Energy
2001-08-06
This case study is the latest in a series on industrial firms who are implementing energy efficient technologies and system improvements into their manufacturing processes. The case studies document the activities, savings, and lessons learned on these projects.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-02
... INFORMATION CONTACT: Joanna Johnson, TSA PRA Officer, Office of Information Technology (OIT), TSA-11... other forms of information technology. Information Collection Requirement Title: Security Program for... surveyor tool that is managed at TSA. Participants who attend the classroom training sessions will also be...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2002-01-01
This case study highlights the upgraded compressed air system at a Michelin tire manufacturing plant in Spartanburg, South Carolina. The controls upgrade project enabled multiple compressor operation without blow-off, and significantly reduced energy costs.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-16
... PRA Officer, Office of Information Technology (OIT), TSA-11, Transportation Security Administration... technological collection techniques or other forms of information technology. Information Collection Requirement... Paperwork Reduction Act Officer, Office of Information Technology. [FR Doc. 2013-19973 Filed 8-15-13; 8:45...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-30
... TSA PRA Officer, Office of Information Technology (OIT), TSA-11, Transportation Security... technological collection techniques or other forms of information technology. Information Collection Requirement... history records check (CHRC), (2) a name-based check to determine whether the individual poses or is...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-26
... Act (PRA) Officer, Office of Information Technology (OIT), TSA-11, Transportation Security..., electronic, mechanical, or other technological collection techniques or other forms of information technology... criminal history records check (CHRC). As part of the CHRC process, the individual must provide identifying...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-03
... delivered to the TSA PRA Officer, Office of Information Technology (OIT), TSA-11, Transportation Security... technological collection techniques or other forms of information technology. Information Collection Requirement... Protection, U.S. Citizenship and Immigration Services, Office of Biometric Information Management, Office of...
Process and methodology of developing Cassini G and C Telemetry Dictionary
NASA Technical Reports Server (NTRS)
Kan, Edwin P.
1994-01-01
While the Cassini spacecraft telemetry design had taken on the new approach of 'packetized telemetry', the AACS (Attitude and Articulation Subsystem) had further extended into the design of 'mini-packets' in its telemetry system. Such telemetry packet and mini-packet design produced the AACS Telemetry Dictionary; iterations of the latter in turn provided changes to the former. The ultimate goals were to achieve maximum telemetry packing density, optimize the 'freshness' of more time-critical data, and to effect flexibility, i.e., multiple AACS data collection schemes, without needing to change the overall spacecraft telemetry mode. This paper describes such a systematic process and methodology, evidenced by various design products related to, or as part of, the AACS Telemetry Dictionary.
A ph sensor based on a flexible substrate
NASA Astrophysics Data System (ADS)
Huang, Wen-Ding
pH sensor is an essential component used in many chemical, food, and bio-material industries. Conventional glass electrodes have been used to construct pH sensors, however, have some disadvantages. Glass electrodes are easily affected by alkaline or HF solution, they require a high input impedance pH meter, they often exhibit a sluggish response. In some specific applications, it is also difficult to use glass electrodes for in vivo biomedical or food monitoring applications due to the difficulty of size miniaturization, planarization and polymerization based on current manufacturing technologies. In this work, we have demonstrated a novel flexible pH sensor based on low-cost sol-gel fabrication process of iridium oxide (IrOx) sensing film (IROF). A pair of flexible miniature IrOx/AgCl electrode generated the action potential from the solution by electrochemical mechanism to obtain the pH level of the reagent. The fabrication process including sol-gel, thermal oxidation, and the electro-plating process of the silver chloride (AgCl) reference electrode were reported in the work. The IrOx film was verified and characterized using electron dispersive analysis (EDAX), scanning electron microscope (SEM), and x-ray diffraction (XRD). The flexible pH sensor's performance and characterization have been investigated with different testing parameters such as sensitivity, response time, stability, reversibility, repeatability, selectivity and temperature dependence. The flexible IrOx pH sensors exhibited promising sensing performance with a near-Nernstian response of sensitivity which is between --51.1mV/pH and --51.7mV/pH in different pH levels ranging from 1.5 to 12 at 25°C. Two applications including gastroesophageal reflux disease (GERD) diagnosis and food freshness wireless monitoring using our micro-flexible IrOx pH sensors were demonstrated. For the GERD diagnosing system, we embedded the micro flexible pH sensor on a 1.2cmx3.8cm of the capsule size of wireless sensor implanted inside the esophagus. Our pH electrode can monitor the pH changes of gastric juice in real time when the reflux happening in the esophagus. Our micro flexible pH sensor performed clear responses in each distinct pH reflux episode quickly and accurately comparing with the other commercial pH monitoring system. For the food freshness monitoring applications, we used the flexible pH sensor as a freshness indicator to monitor the pH changing profile during the food spoilage procedure. The sensor was then embedded with radio frequency identification (RFID) based passive telemetry enabling remote monitoring of food freshness. In the result, our pH-wireless RFID system presented 633Hz/pH of the sensitivity in the frequency calibration. The calibration of stability and dynamical response of the RFID system were also demonstrated before the test on food freshness monitoring. Finally, a white fish meat for long term spoilage procedure monitoring was applied and tested by using our wireless IrOx pH sensing system. Our RFID pH sensing module is able to monitor, collect and transmit the pH information continuously for 18 hours during the food spoilage procedure. In this dissertation, a micro size of IrOx/AgCl pH sensor was fabricated on a flexible substrate. The physical properties of the IrO x thin film was verified in the work. The different sensing capability such as the sensitivity, stability, reversibility, response time, repeatability, selectivity, and temperature dependence was then demonstrated in this work. After the different in-vitro tests, the pH sensor were embedded with our passive RFID circuitry for the in-vivo GERD diagnosis and food freshness monitoring application. Our wireless pH sensing system was able to deliver the accurate and quick pH sensing data wirelessly. In conclusion, our deformable IrOx pH electrodes have been demonstrated with the advantages of accommodating and conforming sensors in small spaces or curved surfaces. This miniature IrOx pH sensor can respond to distinct potentials of the various pH levels as traditional glass electrodes, however, the miniature, bio-compatible and flexible substrate and the ability to be integrated in batterryless telemetry enable the pH sensor to be applied on many new medical, bio-chemical and biological field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodenbeck, Christopher T.; Young, Derek; Chou, Tina
A combined radar and telemetry system is described. The combined radar and telemetry system includes a processing unit that executes instructions, where the instructions define a radar waveform and a telemetry waveform. The processor outputs a digital baseband signal based upon the instructions, where the digital baseband signal is based upon the radar waveform and the telemetry waveform. A radar and telemetry circuit transmits, simultaneously, a radar signal and telemetry signal based upon the digital baseband signal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
U.S. Department of Energy
2001-08-05
This case study is the latest in a series on industrial firms who are implementing energy efficient technologies and system improvements into their manufacturing processes. The case studies document the activities, savings, and lessons learned on these projects.
Evaluation of the Commercial off-the-shelf (COTS) Low Temperature Powder Coating (LTPC)
2017-11-15
isothiazolin- 3-one (OIT) 26530-20-1 120°C 4.9x10-3 (25°C) Isothiazolinone; Mode of Action: Electrophilic active agent. Reacts with nucleophiles (e.g...Action: Electrophilic active agent with activated N-S bond and vinyl activated halogens; reacts with nucleophilic elements of cell proteins
78 FR 55699 - Privacy Act of 1974; Proposed New Systems of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-11
... FMC OIT staff at its Washington, DC headquarters. The FMC GSS is made up of servers, switches, gateways, and two firewall devices. The servers, switches, gateways, and firewall devices are physically... within the confines of FMC-39, FMC General Support System (FMC GSS) and FMC-41, FMC SQL Database (FMCDB...
U.S. EPA, Pesticide Product Label, , 03/27/1989
2011-04-19
... d _n, "un .,t ••• n. c ••• I·'I: U, •• ,00' .".,tr .djult.d to • co"" .. t 'Pu,. Dar"t thl .,,., ta h"'.t ,I" .. , c,.Ck •• n. C".,C'I un G., pl· 'It. "aun' cOIt •• nl'. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-17
... their mental health history. DATES: Send your comments by October 18, 2010. A comment to OMB is most... INFORMATION CONTACT: Joanna Johnson, TSA PRA Officer, Office of Information Technology (OIT), TSA-11... other forms of information technology. Information Collection Requirement Title: Office of Law...
Guideline-based intervention to reduce telemetry rates in a large tertiary centre.
Ramkumar, Satish; Tsoi, Edward H; Raghunath, Ajay; Dias, Floyd F; Li Wai Suen, Christopher; Tsoi, Andrew H; Mansfield, Darren R
2017-07-01
Inappropriate cardiac telemetry use is associated with reduced patient flow and increased healthcare costs. To evaluate the outcomes of guideline-based application of cardiac telemetry. Phase I involved a prospective audit (March to August 2011) of telemetry use at a tertiary hospital. Data were collected on indication for telemetry and clinical outcomes. Phase II prospectively included patients more than 18 years under general medicine requiring ward-based telemetry. As phase II occurred at a time remotely from phase I, an audit similar to phase I (phase II - baseline) was completed prior to a 3-month intervention (May to August 2015). The intervention consisted of a daily telemetry ward round and an admission form based on the American Heart Association guidelines (class I, telemetry indicated; class II, telemetry maybe indicated; class III, telemetry not indicated). Patient demographics, telemetry data, and clinical outcomes were studied. Primary endpoint was the percentage reduction of class III indications, while secondary endpoint included telemetry duration. In phase I (n = 200), 38% were admitted with a class III indication resulting in no change in clinical management. A total of 74 patients was included in phase II baseline (mean ± standard deviation (SD) age 73 years ± 14.9, 57% male), whilst 65 patients were included in the intervention (mean ± SD age 71 years ± 18.4, 35% male). Both groups had similar baseline characteristics. There was a reduction in class III admissions post-intervention from 38% to 11%, P < 0.001. Intervention was associated with a reduction in median telemetry duration (1.8 ± 1.8 vs 2.4 ± 2.5 days, P = 0.047); however, length of stay was similar in both groups (P > 0.05). Guideline-based telemetry admissions and a regular telemetry ward round are associated with a reduction in inappropriate telemetry use. © 2017 Royal Australasian College of Physicians.
Adaptable Transponder for Multiple Telemetry Systems
NASA Technical Reports Server (NTRS)
Sims, William Herbert, III (Inventor); Varnavas, Kosta A. (Inventor)
2014-01-01
The present invention is a stackable telemetry circuit board for use in telemetry systems for satellites and other purposes. The present invention incorporates previously-qualified interchangeable circuit boards, or "decks," that perform functions such as power, signal receiving and transmission, and processing. Each deck is adapted to serve a range of telemetry applications. This provides flexibility in the construction of the stackable telemetry circuit board and significantly reduces the cost and time necessary to develop a telemetry system.
Snipelisky, David; Ray, Jordan; Matcha, Gautam; Roy, Archana; Harris, Dana; Bosworth, Veronica; Dumitrascu, Adrian; Clark, Brooke; Vadeboncoeur, Tyler; Kusumoto, Fred; Bowman, Cammi; Burton, M Caroline
2018-03-01
Our study assesses the utility of telemetry in identifying decompensation in patients with documented cardiopulmonary arrest. A retrospective review of inpatients who experienced a cardiopulmonary arrest from May 1, 2008, until June 30, 2014, was performed. Telemetry records 24 hours prior to and immediately preceding cardiopulmonary arrest were reviewed. Patient subanalyses based on clinical demographics were made as well as analyses of survival comparing patients with identifiable rhythm changes in telemetry to those without. Of 242 patients included in the study, 75 (31.0%) and 110 (45.5%) experienced telemetry changes at the 24-hour and immediately preceding time periods, respectively. Of the telemetry changes, the majority were classified as nonmalignant (n = 50, 66.7% and n = 66, 55.5% at 24 hours prior and immediately preceding, respectively). There was no difference in telemetry changes between intensive care unit (ICU) and non-ICU patients and among patients stratified according to the American Heart Association telemetry indications. There was no difference in survival when comparing patients with telemetry changes immediately preceding and at 24 hours prior to an event (n = 30, 27.3% and n = 15, 20.0%) to those without telemetry changes during the same periods (n = 27, 20.5% and n = 42, 25.2%; P = .22 and .39). Telemetry has limited utility in predicting clinical decompensation in the inpatient setting.
A Scalable, Out-of-Band Diagnostics Architecture for International Space Station Systems Support
NASA Technical Reports Server (NTRS)
Fletcher, Daryl P.; Alena, Rick; Clancy, Daniel (Technical Monitor)
2002-01-01
The computational infrastructure of the International Space Station (ISS) is a dynamic system that supports multiple vehicle subsystems such as Caution and Warning, Electrical Power Systems and Command and Data Handling (C&DH), as well as scientific payloads of varying size and complexity. The dynamic nature of the ISS configuration coupled with the increased demand for payload support places a significant burden on the inherently resource constrained computational infrastructure of the ISS. Onboard system diagnostics applications are hosted on computers that are elements of the avionics network while ground-based diagnostic applications receive only a subset of available telemetry, down-linked via S-band communications. In this paper we propose a scalable, out-of-band diagnostics architecture for ISS systems support that uses a read-only connection for C&DH data acquisition, which provides a lower cost of deployment and maintenance (versus a higher criticality readwrite connection). The diagnostics processing burden is off-loaded from the avionics network to elements of the on-board LAN that have a lower overall cost of operation and increased computational capacity. A superset of diagnostic data, richer in content than the configured telemetry, is made available to Advanced Diagnostic System (ADS) clients running on wireless handheld devices, affording the crew greater mobility for troubleshooting and providing improved insight into vehicle state. The superset of diagnostic data is made available to the ground in near real-time via an out-of band downlink, providing a high level of fidelity between vehicle state and test, training and operational facilities on the ground.
NASA Tech Briefs, February 2011
NASA Technical Reports Server (NTRS)
2011-01-01
Topics covered include: Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly; Fiber-Optic Magnetic-Field-Strength Measurement System for Lightning Detection; Photocatalytic Active Radiation Measurements and Use; Computer Generated Hologram System for Wavefront Measurement System Calibration; Non-Contact Thermal Properties Measurement with Low-Power Laser and IR Camera System; SpaceCube 2.0: An Advanced Hybrid Onboard Data Processor; CMOS Imager Has Better Cross-Talk and Full-Well Performance; High-Performance Wireless Telemetry; Telemetry-Based Ranging; JWST Wavefront Control Toolbox; Java Image I/O for VICAR, PDS, and ISIS; X-Band Acquisition Aid Software; Antimicrobial-Coated Granules for Disinfecting Water; Range 7 Scanner Integration with PaR Robot Scanning System; Methods of Antimicrobial Coating of Diverse Materials; High-Operating-Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength; A Model of Reduced Kinetics for Alkane Oxidation Using Constituents and Species for N-Heptane; Thermally Conductive Tape Based on Carbon Nanotube Arrays; Two Catalysts for Selective Oxidation of Contaminant Gases; Nanoscale Metal Oxide Semiconductors for Gas Sensing; Lightweight, Ultra-High-Temperature, CMC-Lined Carbon/Carbon Structures; Sample Acquisition and Handling System from a Remote Platform; Improved Rare-Earth Emitter Hollow Cathode; High-Temperature Smart Structures for Engine Noise Reduction and Performance Enhancement; Cryogenic Scan Mechanism for Fourier Transform Spectrometer; Piezoelectric Rotary Tube Motor; Thermoelectric Energy Conversion Technology for High-Altitude Airships; Combustor Computations for CO2-Neutral Aviation; Use of Dynamic Distortion to Predict and Alleviate Loss of Control; Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards; and A (201)Hg+ Comagnetometer for (199)Hg+ Trapped Ion Space Atomic Clocks.
106-17 Telemetry Standards Digitized Audio Telemetry Standard Chapter 5
2017-07-01
RCC Standard 106-17 Chapter 5, July 2017 5-3 5.8 CVSD Bit Rate Determination The following discussion provides a procedure for determining the...Telemetry Standards , RCC Standard 106-17 Chapter 5, July 2017 CHAPTER 5 Digitized Audio Telemetry Standard Table of Contents Chapter 5...Digitized Audio Telemetry Standard ............................................................... 5-1 5.1 General
Radio telemetry equipment and applications for carnivores
Fuller, Mark R.; Fuller, Todd K.; Boitani, Luigi; Powell, Roger A.
2012-01-01
Radio-telemetry was not included in the first comprehensive manual of wildlife research techniques (Mosby 1960) because the first published papers were about physiological wildlife telemetry (LeMunyan et al. 1959) and because research using telemetry in field ecology was just being initiated (Marshall et al. 1962; Cochran and Lord 1963). Among the first uses of telemetry to study wildlife, however, was a study of carnivores (Craighead et al. 1963), and telemetry has become a common method for studying numerous topics of carnivore biology. Our goals for this chapter are to provide basic information about radio-telemetry equipment and procedures. Although we provide many references to studies using telemetry equipment and methods, we recommend Kenward's (2001) comprehensive book, A manual of wildlife radio tagging for persons who are unfamiliar with radio-telemetry, Fuller et al. (2005), and Tomkiewicz et al. (2010). Compendia of uses of radio-telemetry in animal research appear regularly as chapters in manuals (Cochran 1980; Samuel and Fuller 1994), in books about equipment, field procedures, study design, and applications (Amlaner and Macdonald 1980; Anderka 1987; Amlaner 1989; White and Garrott 1990; Priede and Swift 1992; Kenward 2001; Millspaugh and Marzluff 2001; Mech and Barber 2002), and in reviews highlighting new developments (Cooke et al. 2004; Rutz and Hays 2009; Cagnacci et al. 2010). Some animal telemetry products and techniques have remained almost unchanged for years, but new technologies and approaches emerge and replace previously available equipment at an increasing pace. Here, we emphasize recent studies for which telemetry was used with carnivores.
76 FR 10082 - Office of International Trade; State Trade and Export Promotion (STEP) Grant Program
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-23
... (STEP) Grant Program AGENCY: U.S. Small Business Administration (SBA). ACTION: Notice of grant... Program Announcement No. OIT-STEP-2011- 01 to invite the States, the District of Columbia and the U.S. Territories to apply for a STEP grant to carry out export promotion programs that assist eligible small...
ERIC Educational Resources Information Center
Raufelder, Diana; Hoferichter, Frances; Schneeweiss, David; Wood, Megan A.
2015-01-01
Based on cognitive evaluation theory (CET) and organismic integration theory (OIT)--both sub-theories of self-determination theory (SDT)--the present study examined whether the academic self-regulation of youth with test anxiety can be strengthened through social and motivational relationships with peers and teachers. This study employed a large…
Development and Flight Testing of an Autonomous Landing Gear Health-Monitoring System
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Taylor, B. Douglas; Brett, Rube R.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.
2003-01-01
Development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation; and, data acquisition, storage and retrieval.
106-17 Telemetry Standards Chapter 1
2017-07-01
Telemetry Standards , RCC Standard 106-17 Chapter 1, July 2017 1-1 CHAPTER 1 Introduction The Telemetry Standards address the here-to-date...generally devoted to a different element of the telemetry system or process . Chapters 21 through 28 address the topic of network telemetry. These...Commonly used terms are defined in standard reference glossaries and dictionaries. Definitions of terms with special applications are included when
Rapidly Deployed Modular Telemetry System
NASA Technical Reports Server (NTRS)
Varnavas, Kosta A. (Inventor); Sims, William Herbert, III (Inventor)
2013-01-01
The present invention is a telemetry system, and more specifically is a rapidly deployed modular telemetry apparatus which utilizes of SDR technology and the FPGA programming capability to reduce the number of hardware components and programming required to deploy a telemetry system.
XTCE. XML Telemetry and Command Exchange Tutorial
NASA Technical Reports Server (NTRS)
Rice, Kevin; Kizzort, Brad; Simon, Jerry
2010-01-01
An XML Telemetry Command Exchange (XTCE) tutoral oriented towards packets or minor frames is shown. The contents include: 1) The Basics; 2) Describing Telemetry; 3) Describing the Telemetry Format; 4) Commanding; 5) Forgotten Elements; 6) Implementing XTCE; and 7) GovSat.
Optimization of radio telemetry receiving systems: Chapter 5.2
Evans, Scott D.; Stevenson, John R.; Adams, Noah S.; Beeman, John W.; Eiler, John H.
2012-01-01
Telemetry provides a powerful and flexible tool for studying fish and other aquatic animals, and its use has become increasingly commonplace. However, telemetry is gear intensive and typically requires more specialized knowledge and training than many other field techniques. As with other scientific methods, collecting good data is dependent on an understanding of the underlying principles behind the approach, knowing how to use the equipment and techniques properly, and recognizing what to do with the data collected. This book provides a road map for using telemetry to study aquatic animals, and provides the basic information needed to plan, implement, and conduct a telemetry study under field conditions. Topics include acoustic or radio telemetry study design, tag implantation techniques, radio and acoustic telemetry principles and case studies, and data management and analysis.
A history of telemetry in fishery research: Chapter 2
Hockersmith, Eric; Beeman, John W.; Adams, Noah S.; Beeman, John W.; Eiler, John H.
2012-01-01
Telemetry provides a powerful and flexible tool for studying fish and other aquatic animals, and its use has become increasingly commonplace. However, telemetry is gear intensive and typically requires more specialized knowledge and training than many other field techniques. As with other scientific methods, collecting good data is dependent on an understanding of the underlying principles behind the approach, knowing how to use the equipment and techniques properly, and recognizing what to do with the data collected. This book provides a road map for using telemetry to study aquatic animals, and provides the basic information needed to plan, implement, and conduct a telemetry study under field conditions. Topics include acoustic or radio telemetry study design, tag implantation techniques, radio and acoustic telemetry principles and case studies, and data management and analysis.
2012-09-01
downconverters; telemetry RF preamplifiers; telemetry multicouplers; telemetry receivers 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT Same as...Continuing Engineering Education Program, George Washington University , 1994. A-5 Figure A-2. Graphical representation of intercept point...NFdb) is expressed in decibels and noise factor (nf ) in decimal units. For example, a noise figure of 3 dB corresponds to a noise factor of 2
Scientific Performance Analysis of the SYZ Telescope Design versus the RC Telescope Design
NASA Astrophysics Data System (ADS)
Ma, Donglin; Cai, Zheng
2018-02-01
Recently, Su et al. propose an innovative design, referred as the “SYZ” design, for China’s new project of a 12 m optical-infrared telescope. The SYZ telescope design consists of three aspheric mirrors with non-zero power, including a relay mirror below the primary mirror. SYZ design yields a good imaging quality and has a relatively flat field curvature at Nasmyth focus. To evaluate the science-compatibility of this three-mirror telescope, in this paper, we thoroughly compare the performance of SYZ design with that of Ritchey–Chrétien (RC) design, a conventional two-mirror telescope design. Further, we propose the Observing Information Throughput (OIT) as a metric for quantitatively evaluating the telescopes’ science performance. We find that although a SYZ telescope yields a superb imaging quality over a large field of view, a two-mirror (RC) telescope design holds a higher overall throughput, a better diffraction-limited imaging quality in the central field of view (FOV < 5‧) which is better for the performance of extreme Adaptive Optics (AO), and a generally better scientific performance with a higher OIT value. D. Ma & Z. Cai contributed equally to this paper.
The Advanced Industrial Materials (AIM) program office of industrial technologies fiscal year 1995
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorrell, C.A.
1997-04-01
In many ways, the Advanced Industrial Materials (AIM) Program underwent a major transformation in FY95 and these changes have continued to the present. When the Program was established in 1990 as the Advanced Industrial Concepts (AIC) Materials Program, the mission was to conduct applied research and development to bring materials and processing technologies from the knowledge derived from basic research to the maturity required for the end use sectors for commercialization. In 1995, the Office of Industrial Technologies (OIT) made radical changes in structure and procedures. All technology development was directed toward the seven `Vision Industries` that use about 80%more » of industrial energy and generated about 90% of industrial wastes. These are: aluminium; chemical; forest products; glass; metal casting; refineries; and steel. OIT is working with these industries, through appropriate organizations, to develop Visions of the desired condition of each industry some 20 to 25 years in the future and then to prepare Road Maps and Implementation Plans to enable them to reach their goals. The mission of AIM has, therefore, changed to `Support development and commercialization of new or improved materials to improve productivity, product quality, and energy efficiency in the major process industries.`« less
Mišić, Jelena; (Sherman) Shen, Xuemin
2009-01-01
We consider interconnection of IEEE 802.15.4 beacon-enabled network cluster with IEEE 802.11b network. This scenario is important in healthcare applications where IEEE 802.15.4 nodes comprise patient's body area network (BAN) and are involved in sensing some health-related data. BAN nodes have very short communication range in order to avoid harming patient's health and save energy. Sensed data needs to be transmitted to an access point in the ward room using wireless technology with higher transmission range and rate such as IEEE 802.11b. We model the interconnected network where IEEE 802.15.4-based BAN operates in guaranteed time slot (GTS) mode, and IEEE 802.11b part of the bridge conveys GTS superframe to the 802.11b access point. We then analyze the network delays. Performance analysis is performed using EKG traffic from continuous telemetry, and we discuss the delays of communication due the increasing number of patients. PMID:19107184
Implementation of body area networks based on MICS/WMTS medical bands for healthcare systems.
Yuce, Mehmet R; Ho, Chee Keong
2008-01-01
A multi-hoping sensor network system has been implemented to monitor physiological parameters from multiple patient bodies by means of medical communication standards MICS (Medical Implant Communication Service) and WMTS (Wireless Medical Telemetry Service). Unlike the other medical sensor networks (they usually use 2.4 GHz ISM band), we used the two medical standards occupying the frequency bands that are mainly assigned to medical applications. The prototype system uses the MICS band (402-405 MHz) between the sensor nodes and a remote central control unit (CCU). And WMTS frequencies (608-614MHz) are used between the CCUs and the remote base stations allowing for a much larger range acting as an intermediate node. The sensor nodes in the prototype can measure up to four body signals (i.e. 4-channel) where one is dedicated to a continuous physiological signal such as ECC/EEG. The system includes firmware and software designs that can provide a long distance data transfer through the internet or a mobile network.
Misić, Jelena; Sherman Shen, Xuemin
2009-01-01
We consider interconnection of IEEE 802.15.4 beacon-enabled network cluster with IEEE 802.11b network. This scenario is important in healthcare applications where IEEE 802.15.4 nodes comprise patient's body area network (BAN) and are involved in sensing some health-related data. BAN nodes have very short communication range in order to avoid harming patient's health and save energy. Sensed data needs to be transmitted to an access point in the ward room using wireless technology with higher transmission range and rate such as IEEE 802.11b. We model the interconnected network where IEEE 802.15.4-based BAN operates in guaranteed time slot (GTS) mode, and IEEE 802.11b part of the bridge conveys GTS superframe to the 802.11b access point. We then analyze the network delays. Performance analysis is performed using EKG traffic from continuous telemetry, and we discuss the delays of communication due the increasing number of patients.
Closed loop deep brain stimulation: an evolving technology.
Hosain, Md Kamal; Kouzani, Abbas; Tye, Susannah
2014-12-01
Deep brain stimulation is an effective and safe medical treatment for a variety of neurological and psychiatric disorders including Parkinson's disease, essential tremor, dystonia, and treatment resistant obsessive compulsive disorder. A closed loop deep brain stimulation (CLDBS) system automatically adjusts stimulation parameters by the brain response in real time. The CLDBS continues to evolve due to the advancement in the brain stimulation technologies. This paper provides a study on the existing systems developed for CLDBS. It highlights the issues associated with CLDBS systems including feedback signal recording and processing, stimulation parameters setting, control algorithm, wireless telemetry, size, and power consumption. The benefits and limitations of the existing CLDBS systems are also presented. Whilst robust clinical proof of the benefits of the technology remains to be achieved, it has the potential to offer several advantages over open loop DBS. The CLDBS can improve efficiency and efficacy of therapy, eliminate lengthy start-up period for programming and adjustment, provide a personalized treatment, and make parameters setting automatic and adaptive.
Zayachkivsky, Andrew; Lehmkuhle, Mark J.; Dudek, F. Edward
2015-01-01
Many progressive neurologic diseases in humans, such as epilepsy, require pre-clinical animal models that slowly develop the disease in order to test interventions at various stages of the disease process. These animal models are particularly difficult to implement in immature rodents, a classic model organism for laboratory study of these disorders. Recording continuous EEG in young animal models of seizures and other neurological disorders presents a technical challenge due to the small physical size of young rodents and their dependence on the dam prior to weaning. Therefore, there is not only a clear need for improving pre-clinical research that will better identify those therapies suitable for translation to the clinic but also a need for new devices capable of recording continuous EEG in immature rodents. Here, we describe the technology behind and demonstrate the use of a novel miniature telemetry system, specifically engineered for use in immature rats or mice, which is also effective for use in adult animals. PMID:26274779
Ramshur, John T; de Jongh Curry, Amy L; Waters, Robert S
2014-01-01
We describe for the first time the design, implementation, and testing of a telemetry controlled simultaneous stimulation and recording device (SRD) to deliver chronic intercortical microstimulation (ICMS) to physiologically identified sites in rat somatosensory cortex (SI) and test hypotheses that chronic ICMS strengthens interhemispheric pathways and leads to functional reorganization in the enhanced cortex. The SRD is a custom embedded device that uses the Cypress Semiconductor's programmable system on a chip (PSoC) that is remotely controlled via Bluetooth. The SRC can record single or multiunit responses from any two of 12 available inputs at 1-15 ksps per channel and simultaneously deliver stimulus pulses (0-255 μA; 10 V compliance) to two user selectable electrodes using monophasic, biphasic, or pseudophasic stimulation waveforms (duration: 0-5 ms, inter-phase interval: 0-5 ms, frequency: 0.1-5 s, delay: 0-10 ms). The SRD was bench tested and validated in vivo in a rat animal model.
Simmons, Scott C; Murphy, Timothy A; Blanarovich, Adrian; Workman, Florence T; Rosenthal, David A; Carbone, Matthew
2003-01-01
Effective response to natural or man-made disasters (i.e., terrorism) is predicated on the ability to communicate among the many organizations involved. Disaster response exercises enable disaster planners and responders to test procedures and technologies and incorporate the lessons learned from past disasters or exercises. On May 31 and June 1, 2002, one such exercise event took place at the Camp Lejeune Marine Corps Base in Jacksonville, North Carolina. During the exercise, East Carolina University tested: (1) in-place Telehealth networks and (2) rapidly deployable communications, networking, and data collection technologies such as satellite communications, local wireless networking, on-scene video, and clinical and environmental data acquisition and telemetry. Exercise participants included local, county, state, and military emergency medical services (EMS), emergency management, specialized response units, and local fire and police units. The technologies and operations concepts tested at the exercise and recommendations for using telehealth to improve disaster response are described.
Simmons, Scott C.; Murphy, Timothy A.; Blanarovich, Adrian; Workman, Florence T.; Rosenthal, David A.; Carbone, Matthew
2003-01-01
Effective response to natural or man-made disasters (i.e., terrorism) is predicated on the ability to communicate among the many organizations involved. Disaster response exercises enable disaster planners and responders to test procedures and technologies and incorporate the lessons learned from past disasters or exercises. On May 31 and June 1, 2002, one such exercise event took place at the Camp Lejeune Marine Corps Base in Jacksonville, North Carolina. During the exercise, East Carolina University tested: (1) in-place Telehealth networks and (2) rapidly deployable communications, networking, and data collection technologies such as satellite communications, local wireless networking, on-scene video, and clinical and environmental data acquisition and telemetry. Exercise participants included local, county, state, and military emergency medical services (EMS), emergency management, specialized response units, and local fire and police units. The technologies and operations concepts tested at the exercise and recommendations for using telehealth to improve disaster response are described. PMID:12595406
LANDSAT-D data format control book. Volume 2: Telemetry
NASA Technical Reports Server (NTRS)
Talipsky, R.
1982-01-01
The formats used for the transmission of LANDSAT-D and LANDSAT-D Prime spacecraft telemetry data through either the TDRS/GSTDN via the NASCOM Network to the CSF are described as well as the telemetry flow from the command and data handling subsystem, a telemetry list and telemetry matrix assignment for the mission and engineering formats. The on-board computer (OBC) controlled format and the dwell format are also discussed. The OBCs contribution to telemetry, and the format of the reports, are covered. The high rate data channel includes the payload correction data format, the narrowband tape recorder and the OBC dump formats.
Next-Generation Telemetry Workstation
NASA Technical Reports Server (NTRS)
2008-01-01
A next-generation telemetry workstation has been developed to replace the one currently used to test and control Range Safety systems. Improving upon the performance of the original system, the new telemetry workstation uses dual-channel telemetry boards for better synchronization of the two uplink telemetry streams. The new workstation also includes an Interrange Instrumentation Group/Global Positioning System (IRIG/GPS) time code receiver board for independent, local time stamping of return-link data. The next-generation system will also record and play back return-link data for postlaunch analysis.
NASA Technical Reports Server (NTRS)
Chang, Chen J. (Inventor); Liaghati, Jr., Amir L. (Inventor); Liaghati, Mahsa L. (Inventor)
2018-01-01
Methods and apparatus are provided for telemetry processing using a telemetry processor. The telemetry processor can include a plurality of communications interfaces, a computer processor, and data storage. The telemetry processor can buffer sensor data by: receiving a frame of sensor data using a first communications interface and clock data using a second communications interface, receiving an end of frame signal using a third communications interface, and storing the received frame of sensor data in the data storage. After buffering the sensor data, the telemetry processor can generate an encapsulated data packet including a single encapsulated data packet header, the buffered sensor data, and identifiers identifying telemetry devices that provided the sensor data. A format of the encapsulated data packet can comply with a Consultative Committee for Space Data Systems (CCSDS) standard. The telemetry processor can send the encapsulated data packet using a fourth and a fifth communications interfaces.
A Configurable Internet Telemetry Server / Remote Client System
NASA Astrophysics Data System (ADS)
Boyd, W. T.; Hopkins, A.; Abbott, M. J.; Girouard, F. R.
2000-05-01
We have created a general, object-oriented software framework in Java for remote viewing of telemetry over the Internet. The general system consists of a data server and a remote client that can be extended by any project that uses telemetry to implement a remote telemetry viewer. We have implemented a system that serves live telemetry from NASA's Extreme Ultraviolet Explorer satellite and a client that can display the telemetry at a remote location. An authenticated user may run a standalone graphical or text-based client, or an applet on a web page, to view EUVE telemetry. In the case of the GUI client, a user can build displays to his/her own specifications using a GUI view-building tool. This work was supported by grants NCC2-947 and NCC2-966 from NASA Ames Research Center and grant JPL-960684 from NASA Jet Propulsion Laboratory.
Missile telemetry systems for flight tests and EMC tests on EED's
NASA Astrophysics Data System (ADS)
Freymann, D.
1985-06-01
This paper describes telemetry systems developed for use in the 'Roland', 'MLRS AT2' and 'Kormoran' missiles. The main design effort required to obtain a high performance of telemetry data acquisition and transmission under extreme environmental conditions are discussed, along with test results. Considered are different types of PCM telemetry systems where the data is either transmitted directly to the ground via an RF or fiber optic link or stored in an onboard solid-state memory. The safety of EEDs in the presence of unwanted electromagnetic fields or currents is very important in weapon-systems. Therefore another type of telemetry system is reported here allowing the measurement of extremely small DC- and RF-currents induced on EEDs during EMC ground-tests. These telemetry signals are transmitted via fiber optics, to avoid additional coupling. Finally, there is a brief commentary on the future design philosophy of missile telemetry systems.
Turner, Daniel C.; Samuels, Brian C.; Huisingh, Carrie; Girkin, Christopher A.
2017-01-01
Purpose To study the effect and time course of body position changes on IOP in nonhuman primates. Methods We recorded continuous bilateral IOP measurements with a wireless telemetry implant in three rhesus macaques in seven different body positions. IOP measurements were acquired in the seated-upright, standing, prone, supine, right and left lateral decubitus positions (LDPs), and head-down inverted positions. Continuous IOP was recorded for 90 seconds in each position before returning to a supine reference position until IOP stabilized; measurements were averaged after IOP stabilized at each position. Results Head-down inversion increased IOP an average of 8.9 mm Hg, compared to the supine reference. In the LDP, IOP decreased an average of 0.5 mm Hg in the nondependent eye (i.e., the higher eye), while the fellow dependent (i.e., lower) eye increased an average of 0.5 mm Hg, compared to supine reference. Standing and seated positions decreased IOP 1.5 and 2.2 mm Hg, respectively, compared with supine reference. IOP changes occurred within 4 to 15 seconds of a body position change, and timing was affected by the speed at which body position was changed. Compared to the IOP in the supine position, the IOP in the inverted, prone, and seated positions was significantly different (P = 0.0313 for all). The IOP in the standing position was not statistically different from the IOP in the supine position (P = 0.094). In addition, the IOP was significantly different between the nondependent eye and the dependent eye in the LDPs compared to the supine position (P = 0.0313). Conclusions Body position has a significant effect on IOP and those changes persist over time. PMID:29228251
Photodegradation and Photophysics of Laser Dyes
1994-06-30
research. "The Photophysics and Photochem istry of’ Orgainic Laser Dyecs uander Conditions oit Binding to Polymethacrylic Acid in Water** thcsis...c 13. ABSTRACT (Maximum 200 wotrds) 6 The solubilization of laser dyes in water with the aid of the polyelectrolyte, poly(methacr,-- lic acid ) (PMAA...moderately acidic pH. Polymer-bound dyes in water display markedly enhanced emission yield, lifetime, and polarization. Dye materials are also less
This report documents the activities performed during and the results obtained from the arsenic removal treatment technology demonstration project at Oregon Institute of Technology (OIT) at Klamath Falls, OR. The objectives of the project were to evaluate: (1) the effectiveness...
LANDSAT-4 to ground station interface description
NASA Technical Reports Server (NTRS)
1983-01-01
The LANDSAT 4 to ground station interface is described in detail. The radiometric specifications, internal calibration, sensor output format, and data processing constants for the multispectral scanner and the thematic mapper are discussed. The mission payload telemetry, onboard computer telemetry, and engineering telemetry formats are described. In addition, the telemetry time signals and the onboard clock resetting procedure are addressed.
Advanced Telemetry System Development.
Progress in advanced telemetry system development is described. Discussions are included of studies leading to the specification for design...characteristics of adaptive and analytical telemetry systems in which the information efficiently utilizes the data channel capacity. Also discussed are...Progress indicates that further sophistication of existing designs in telemetry will be less advantageous than the development of new systems of
Increased flexibility for modeling telemetry and nest-survival data using the multistate framework
Devineau, Olivier; Kendall, William L.; Doherty, Paul F.; Shenk, Tanya M.; White, Gary C.; Lukacs, Paul M.; Burnham, Kenneth P.
2014-01-01
Although telemetry is one of the most common tools used in the study of wildlife, advances in the analysis of telemetry data have lagged compared to progress in the development of telemetry devices. We demonstrate how standard known-fate telemetry and related nest-survival data analysis models are special cases of the more general multistate framework. We present a short theoretical development, and 2 case examples regarding the American black duck and the mallard. We also present a more complex lynx data analysis. Although not necessary in all situations, the multistate framework provides additional flexibility to analyze telemetry data, which may help analysts and biologists better deal with the vagaries of real-world data collection.
Detection, Identification, Location, and Remote Sensing using SAW RFID Sensor Tags
NASA Technical Reports Server (NTRS)
Barton, Richard J.
2009-01-01
In this presentation, we will consider the problem of simultaneous detection, identification, location estimation, and remote sensing for multiple objects. In particular, we will describe the design and testing of a wireless system capable of simultaneously detecting the presence of multiple objects, identifying each object, and acquiring both a low-resolution estimate of location and a high-resolution estimate of temperature for each object based on wireless interrogation of passive surface acoustic wave (SAW) radiofrequency identification (RFID) sensor tags affixed to each object. The system is being studied for application on the lunar surface as well as for terrestrial remote sensing applications such as pre-launch monitoring and testing of spacecraft on the launch pad and monitoring of test facilities. The system utilizes a digitally beam-formed planar receiving antenna array to extend range and provide direction-of-arrival information coupled with an approximate maximum-likelihood signal processing algorithm to provide near-optimal estimation of both range and temperature. The system is capable of forming a large number of beams within the field of view and resolving the information from several tags within each beam. The combination of both spatial and waveform discrimination provides the capability to track and monitor telemetry from a large number of objects appearing simultaneously within the field of view of the receiving array. In the presentation, we will summarize the system design and illustrate several aspects of the operational characteristics and signal structure. We will examine the theoretical performance characteristics of the system and compare the theoretical results with results obtained from experiments in both controlled laboratory environments and in the field.
Remote Arrhythmia Monitoring System Developed
NASA Technical Reports Server (NTRS)
York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.
2004-01-01
Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.
Reliable intraocular pressure measurement using automated radio-wave telemetry.
Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B
2014-01-01
To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.
The Venus Balloon Project telemetry processing
NASA Technical Reports Server (NTRS)
Urech, J. M.; Chamarro, A.; Morales, J. L.; Urech, M. A.
1986-01-01
The peculiarities of the Venus Balloon telemetry system required the development of a new methodology for the telemetry processing, since the capabilities of the Deep Space Network (DSN) telemetry system do not include burst processing of short frames with two different bit rates and first bit acquisition. A software package was produced for the non-real time detection, demodulation, and decoding of the telemetry streams obtained from an open loop recording utilizing the DSN spectrum processing subsystem-radio science (DSP-RS). A general description of the resulting software package (DMO-5539-SP) and its adaptability to the real mission's variations is contained.
Terrain Characterization for Trafficability
1993-06-01
pensive and less time-consuming. Although carefully raphy, on vehicle operation. This report focuses on the controlled laboratory tests may be more...relating indentation to soil strength. on a portable test rig or on an off-road vehicle where it A series of controlled experiments to determine the is... Controls and setting values for hydraulic pressures and flow Figure 10. Wheel are test rig (after Wasterhund 1990). 7 Vertical Proximity L ock-Oit~u
Lin, Q-B; Wang, T-J; Song, H; Li, B
2010-12-01
A novel and simple method to detect isothiazolinone-type biocides (2-methyl-3-isothiazolinone (MI), 5-chloro-2-methyl-3-isothiazolinone (CMI), 1,2-benzisothiazolinone (BIT) and 2-octyl-3-isothiazolinone (OIT)) in paper used for food packaging by ultrasonic extraction coupled with UPLC-MS/MS was developed. Parameters affecting process efficiency such as extraction solvents, UPLC mobile phase, gradient elution procedure and MS/MS conditions were studied to optimise the operating conditions. Using the optimised gradient elution procedure, the retention time was less than 6 min. The limits of detection (LODs) were found to be between 0.001 and 0.010 mg kg⁻¹, which was validated using actual concentrations. After diluting the standard solution with a blank matrix, the linear calibration curve ranges were 0.002-1.000 mg kg⁻¹ for BIT and OIT, 0.005-1.000 mg kg⁻¹ for MI, and 0.020-1.000 mg kg⁻¹ for CMI, with correlation coefficients higher than 0.9985 (n = 6). A good level of precision with a mean recovery greater than 81.3% and a relative standard deviation (RSD) less than 6.2% were also obtained. A methodology has been proposed for the analysis of isothiazolinones in paper.
Spitzer Telemetry Processing System
NASA Technical Reports Server (NTRS)
Stanboli, Alice; Martinez, Elmain M.; McAuley, James M.
2013-01-01
The Spitzer Telemetry Processing System (SirtfTlmProc) was designed to address objectives of JPL's Multi-mission Image Processing Lab (MIPL) in processing spacecraft telemetry and distributing the resulting data to the science community. To minimize costs and maximize operability, the software design focused on automated error recovery, performance, and information management. The system processes telemetry from the Spitzer spacecraft and delivers Level 0 products to the Spitzer Science Center. SirtfTlmProc is a unique system with automated error notification and recovery, with a real-time continuous service that can go quiescent after periods of inactivity. The software can process 2 GB of telemetry and deliver Level 0 science products to the end user in four hours. It provides analysis tools so the operator can manage the system and troubleshoot problems. It automates telemetry processing in order to reduce staffing costs.
Spacecraft operations automation: Automatic alarm notification and web telemetry display
NASA Astrophysics Data System (ADS)
Short, Owen G.; Leonard, Robert E.; Bucher, Allen W.; Allen, Bryan
1999-11-01
In these times of Faster, Better, Cheaper (FBC) spacecraft, Spacecraft Operations Automation is an area that is targeted by many Operations Teams. To meet the challenges of the FBC environment, the Mars Global Surveyor (MGS) Operations Team designed and quickly implemented two new low-cost technologies: one which monitors spacecraft telemetry, checks the status of the telemetry, and contacts technical experts by pager when any telemetry datapoints exceed alarm limits, and a second which allows quick and convenient remote access to data displays. The first new technology is Automatic Alarm Notification (AAN). AAN monitors spacecraft telemetry and will notify engineers automatically if any telemetry is received which creates an alarm condition. The second new technology is Web Telemetry Display (WTD). WTD captures telemetry displays generated by the flight telemetry system and makes them available to the project web server. This allows engineers to check the health and status of the spacecraft from any computer capable of connecting to the global internet, without needing normally-required specialized hardware and software. Both of these technologies have greatly reduced operations costs by alleviating the need to have operations engineers monitor spacecraft performance on a 24 hour per day, 7 day per week basis from a central Mission Support Area. This paper gives details on the design and implementation of AAN and WTD, discusses their limitations, and lists the ongoing benefits which have accrued to MGS Flight Operations since their implementation in late 1996.
XTCE: XML Telemetry and Command Exchange Tutorial, XTCE Version 1
NASA Technical Reports Server (NTRS)
Rice, Kevin; Kizzort, Brad
2008-01-01
These presentation slides are a tutorial on XML Telemetry and Command Exchange (XTCE). The goal of XTCE is to provide an industry standard mechanism for describing telemetry and command streams (particularly from satellites.) it wiill lower cost and increase validation over traditional formats, and support exchange or native format.XCTE is designed to describe bit streams, that are typical of telemetry and command in the historic space domain.
Network Science Research Laboratory (NSRL) Telemetry Warehouse
2016-06-01
Functionality and architecture of the NSRL Telemetry Warehouse are also described as well as the web interface, data structure, security aspects, and...Experiment Controller 6 4.5 Telemetry Sensors 7 4.6 Custom Data Processing Nodes 7 5. Web Interface 8 6. Data Structure 8 6.1 Measurements 8...telemetry in comma-separated value (CSV) format from the web interface or via custom applications developed by researchers using the client application
2017-07-01
any of the listed reference frequencies may be used provided the requirements for compensation rate of change are satisfied. If the reference...for in present discriminator systems when the nominal response rating of the channels is employed and a reference frequency is recorded with the...Telemetry Standards, RCC Standard 106-17 Chapter 3, July 2017 3-i CHAPTER 3 Frequency Division Multiplexing Telemetry Standards Acronyms
Telemetry: Summary of concept and rationale
NASA Astrophysics Data System (ADS)
1987-12-01
This report presents the concept and supporting rationale for the telemetry system developed by the Consultative Committee for Space Data Systems (CCSDS). The concepts, protocols and data formats developed for the telemetry system are designed for flight and ground data systems supporting conventional, contemporary free-flyer spacecraft. Data formats are designed with efficiency as a primary consideration, i.e., format overhead is minimized. The results reflect the consensus of experts from many space agencies. An overview of the CCSDS telemetry system introduces the notion of architectural layering to achieve transparent and reliable delivery of scientific and engineering sensor data (generated aboard space vehicles) to users located in space or on earth. The system is broken down into two major conceptual categories: a packet telemetry concept and a telemetry channel coding concept. Packet telemetry facilitates data transmission from source to user in a standardized and highly automated manner. It provides a mechanism for implementing common data structures and protocols which can enhance the development and operation of space mission systems. Telemetry channel coding is a method by which data can be sent from a source to a destination by processing it in such a way that distinct messages are created which are easily distinguishable from one another. This allows construction of the data with low error probability, thus improving performance of the channel.
Satellite relay telemetry of seismic data in earthquake prediction and control
Jackson, Wayne H.; Eaton, Jerry P.
1971-01-01
The Satellite Telemetry Earthquake Monitoring Program was started in FY 1968 to evaluate the applicability of satellite relay telemetry in the collection of seismic data from a large number of dense seismograph clusters laid out along the major fault systems of western North America. Prototype clusters utilizing phone-line telemetry were then being installed by the National Center for Earthquake Research (NCER) in 3 regions along the San Andreas fault in central California; and the experience of installing and operating the clusters and in reducing and analyzing the seismic data from them was to provide the raw materials for evaluation in the satellite relay telemetry project.
Application of harmonic detection technology in methane telemetry
NASA Astrophysics Data System (ADS)
Huo, Yuehua; Fan, Weiqiang
2017-08-01
Methane telemetry plays a vital role in ensuring the safe production of coal mines and monitoring the leakage of natural gas pipelines. Harmonic detection is the key technology of methane telemetry accuracy and sensitivity, but the current telemetry distance is short, the relationship between different modulation parameters is complex, and the harmonic signal is affected by noise interference. These factors seriously affect the development of harmonic detection technology. In this paper, the principle of methane telemetry based on harmonic detection technology is introduced. The present situation and characteristics of harmonic detection technology are expounded. The problems existing in harmonic detection are analyzed. Finally, the future development trend is discussed.
Toward a national animal telemetry network for aquatic observations in the United States
Block, Barbara A.; Holbrook, Christopher; Simmons, Samantha E; Holland, Kim N; Ault, Jerald S.; Costa, Daniel P.; Mate, Bruce R; Seitz, Andrew C.; Arendt, Michael D.; Payne, John; Mahmoudi, Behzad; Moore, Peter L.; Price, James; J. J. Levenson,; Wilson, Doug; Kochevar, Randall E
2016-01-01
Animal telemetry is the science of elucidating the movements and behavior of animals in relation to their environment or habitat. Here, we focus on telemetry of aquatic species (marine mammals, sharks, fish, sea birds and turtles) and so are concerned with animal movements and behavior as they move through and above the world’s oceans, coastal rivers, estuaries and great lakes. Animal telemetry devices (“tags”) yield detailed data regarding animal responses to the coupled ocean–atmosphere and physical environment through which they are moving. Animal telemetry has matured and we describe a developing US Animal Telemetry Network (ATN) observing system that monitors aquatic life on a range of temporal and spatial scales that will yield both short- and long-term benefits, fill oceanographic observing and knowledge gaps and advance many of the U.S. National Ocean Policy Priority Objectives. ATN has the potential to create a huge impact for the ocean observing activities undertaken by the U.S. Integrated Ocean Observing System (IOOS) and become a model for establishing additional national-level telemetry networks worldwide.
An Evaluation and Demonstration of a Network Based Aircraft Telemetry System
NASA Technical Reports Server (NTRS)
Waldersen, Matt; Schnarr, Otto, III
2017-01-01
The primary topics of this presentation describe the testing of network based telemetry and RF modulation techniques. The overall intend is to aid the aerospace industry in transitioning to a network based telemetry system.
A Simulation Testbed for Adaptive Modulation and Coding in Airborne Telemetry
2014-05-29
its modulation waveforms and LDPC for the FEC codes . It also uses several sets of published telemetry channel sounding data as its channel models...waveforms and LDPC for the FEC codes . It also uses several sets of published telemetry channel sounding data as its channel models. Within the context...check ( LDPC ) codes with tunable code rates, and both static and dynamic telemetry channel models are included. In an effort to maximize the
Incorporating CCSDS telemetry standards and philosophy on Cassini
NASA Technical Reports Server (NTRS)
Day, John C.; Elson, Anne B.
1995-01-01
The Cassini project at the Jet Propulsion Laboratory (JPL) is implementing a spacecraft telemetry system based on the Consultative Committee for Space Data Systems (CCSDS) packet telemetry standards. Resolving the CCSDS concepts with a Ground Data System designed to handle time-division-multiplexed telemetry and also handling constraints unique to a deep-space planetary spacecraft (such as fixed downlink opportunities, small downlink rates and requirements for on-board data storage) have resulted in spacecraft and ground system design challenges. Solving these design challenges involved adapting and extending the CCSDS telemetry standards as well as changes to the spacecraft and ground system designs. The resulting spacecraft/ground system design is an example of how new ideas and philosophies can be incorporated into existing systems and design approaches without requiring significant rework. In addition, it shows that the CCSDS telemetry standards can be successfully applied to deep-space planetary spacecraft.
Packet telemetry and packet telecommand - The new generation of spacecraft data handling techniques
NASA Technical Reports Server (NTRS)
Hooke, A. J.
1983-01-01
Because of rising costs and reduced reliability of spacecraft and ground network hardware and software customization, standardization Packet Telemetry and Packet Telecommand concepts are emerging as viable alternatives. Autonomous packets of data, within each concept, which are created within ground and space application processes through the use of formatting techniques, are switched end-to-end through the space data network to their destination application processes through the use of standard transfer protocols. This process may result in facilitating a high degree of automation and interoperability because of completely mission-independent-designed intermediate data networks. The adoption of an international guideline for future space telemetry formatting of the Packet Telemetry concept, and the advancement of the NASA-ESA Working Group's Packet Telecommand concept to a level of maturity parallel to the of Packet Telemetry are the goals of the Consultative Committee for Space Data Systems. Both the Packet Telemetry and Packet Telecommand concepts are reviewed.
Transportable telemetry workstation
NASA Technical Reports Server (NTRS)
Collins, Aaron S.
1989-01-01
The goal was to complete the design of a prototype for a Transportable Telemetry Workstation (TTW). The Macintosh 2 is used to provide a low-cost system which can house real-time cards mounted on the NuBus inside the Macintosh 2 plus provide a standardized user interface on the Macintosh 2 console. Prior to a telemetry run, the user will be able to configure his real-time telemetry processing functions from the Macintosh 2 console. During a telemetry run, the real-time cards will store the telemetry data directly on a hard disk while permitting viewing of the data cards on the Macintosh 2 console on various selectable formats. The user will view the cards in terms of the functions they perform and the selectable paths through the cards, it is not required to become involved directly in hardware issue except in terms of the functional configuration of the system components. The TTW will accept telemetry data from an RS422 serial input data bus, pass it through a frame synchronizer card and on to a real time controller card via a telemetry backplane bus. The controller card will then route the data to a hard disk through a SCSI interface, and/or to a user interface on the Macintosh 2 console by way of the Macintosh 2 NuBus. The three major components to be designed, therefore, are the TTW Controller Card, the TTW Synchronizer Card, and the NuBus/Macintosh 2 User Interface. Design and prototyping of this state-of-the-art, transportable, low-cost, easy-to-use multiprocessor telemetry system is continuing. Other functions are planned for the future.
High performance VLSI telemetry data systems
NASA Technical Reports Server (NTRS)
Chesney, J.; Speciale, N.; Horner, W.; Sabia, S.
1990-01-01
NASA's deployment of major space complexes such as Space Station Freedom (SSF) and the Earth Observing System (EOS) will demand increased functionality and performance from ground based telemetry acquisition systems well above current system capabilities. Adaptation of space telemetry data transport and processing standards such as those specified by the Consultative Committee for Space Data Systems (CCSDS) standards and those required for commercial ground distribution of telemetry data, will drive these functional and performance requirements. In addition, budget limitations will force the requirement for higher modularity, flexibility, and interchangeability at lower cost in new ground telemetry data system elements. At NASA's Goddard Space Flight Center (GSFC), the design and development of generic ground telemetry data system elements, over the last five years, has resulted in significant solutions to these problems. This solution, referred to as the functional components approach includes both hardware and software components ready for end user application. The hardware functional components consist of modern data flow architectures utilizing Application Specific Integrated Circuits (ASIC's) developed specifically to support NASA's telemetry data systems needs and designed to meet a range of data rate requirements up to 300 Mbps. Real-time operating system software components support both embedded local software intelligence, and overall system control, status, processing, and interface requirements. These components, hardware and software, form the superstructure upon which project specific elements are added to complete a telemetry ground data system installation. This paper describes the functional components approach, some specific component examples, and a project example of the evolution from VLSI component, to basic board level functional component, to integrated telemetry data system.
Dudgeon, Christine L; Pollock, Kenneth H; Braccini, J Matias; Semmens, Jayson M; Barnett, Adam
2015-07-01
Capture-mark-recapture models are useful tools for estimating demographic parameters but often result in low precision when recapture rates are low. Low recapture rates are typical in many study systems including fishing-based studies. Incorporating auxiliary data into the models can improve precision and in some cases enable parameter estimation. Here, we present a novel application of acoustic telemetry for the estimation of apparent survival and abundance within capture-mark-recapture analysis using open population models. Our case study is based on simultaneously collecting longline fishing and acoustic telemetry data for a large mobile apex predator, the broadnose sevengill shark (Notorhynchus cepedianus), at a coastal site in Tasmania, Australia. Cormack-Jolly-Seber models showed that longline data alone had very low recapture rates while acoustic telemetry data for the same time period resulted in at least tenfold higher recapture rates. The apparent survival estimates were similar for the two datasets but the acoustic telemetry data showed much greater precision and enabled apparent survival parameter estimation for one dataset, which was inestimable using fishing data alone. Combined acoustic telemetry and longline data were incorporated into Jolly-Seber models using a Monte Carlo simulation approach. Abundance estimates were comparable to those with longline data only; however, the inclusion of acoustic telemetry data increased precision in the estimates. We conclude that acoustic telemetry is a useful tool for incorporating in capture-mark-recapture studies in the marine environment. Future studies should consider the application of acoustic telemetry within this framework when setting up the study design and sampling program.
Transportable telemetry workstation
NASA Astrophysics Data System (ADS)
Collins, Aaron S.
1989-09-01
The goal was to complete the design of a prototype for a Transportable Telemetry Workstation (TTW). The Macintosh 2 is used to provide a low-cost system which can house real-time cards mounted on the NuBus inside the Macintosh 2 plus provide a standardized user interface on the Macintosh 2 console. Prior to a telemetry run, the user will be able to configure his real-time telemetry processing functions from the Macintosh 2 console. During a telemetry run, the real-time cards will store the telemetry data directly on a hard disk while permitting viewing of the data cards on the Macintosh 2 console on various selectable formats. The user will view the cards in terms of the functions they perform and the selectable paths through the cards, it is not required to become involved directly in hardware issue except in terms of the functional configuration of the system components. The TTW will accept telemetry data from an RS422 serial input data bus, pass it through a frame synchronizer card and on to a real time controller card via a telemetry backplane bus. The controller card will then route the data to a hard disk through a SCSI interface, and/or to a user interface on the Macintosh 2 console by way of the Macintosh 2 NuBus. The three major components to be designed, therefore, are the TTW Controller Card, the TTW Synchronizer Card, and the NuBus/Macintosh 2 User Interface. Design and prototyping of this state-of-the-art, transportable, low-cost, easy-to-use multiprocessor telemetry system is continuing. Other functions are planned for the future.
The Clear Creek Envirohydrologic Observatory: From Vision Toward Reality
NASA Astrophysics Data System (ADS)
Just, C.; Muste, M.; Kruger, A.
2007-12-01
As the vision of a fully-functional Clear Creek Envirohydrologic Observatory comes closer to reality, the opportunities for significant watershed science advances in the near future become more apparent. As a starting point to approaching this vision, we focused on creating a working example of cyberinfrastructure in the hydrologic and environmental sciences. The system will integrate a broad range of technologies and ideas: wired and wireless sensors, low power wireless communication, embedded microcontrollers, commodity cellular networks, the internet, unattended quality assurance, metadata, relational databases, machine-to-machine communication, interfaces to hydrologic and environmental models, feedback, and external inputs. Hardware: An accomplishment to date is "in-house" developed sensor networking electronics to compliment commercially available communications. The first of these networkable sensors are dielectric soil moisture probes that are arrayed and equipped with wireless connectivity for communications. Commercially available data logging and telemetry-enabled systems deployed at the Clear Creek testbed include a Campbell Scientific CR1000 datalogger, a Redwing 100 cellular modem, a YA Series yagi antenna, a NP12 rechargeable battery, and a BP SX20U solar panel. This networking equipment has been coupled with Hach DS5X water quality sondes, DTS-12 turbidity probes and MicroLAB nutrient analyzers. Software: Our existing data model is an Arc Hydro-based geodatabase customized with applications for extraction and population of the database with third party data. The following third party data are acquired automatically and in real time into the Arc Hydro customized database: 1) geophysical data: 10m DEM and soil grids, soils; 2) land use/land cover data; and 3) eco-hydrological: radar-based rainfall estimates, stream gage, streamlines, and water quality data. A new processing software for data analysis of Acoustic Doppler Current Profilers (ADCP) measurements has been finalized. The software package provides mean flow field and turbulence characteristics obtained by operating the ADCP at fixed points or using the moving-boat approach. Current Work: The current development work is focused on extracting and populating the Clear Creek database with in-situ measurements acquired and transmitted in real time with sensors deployed in the Clear Creek watershed.
Automatic Satellite Telemetry Analysis for SSA using Artificial Intelligence Techniques
NASA Astrophysics Data System (ADS)
Stottler, R.; Mao, J.
In April 2016, General Hyten, commander of Air Force Space Command, announced the Space Enterprise Vision (SEV) (http://www.af.mil/News/Article-Display/Article/719941/hyten-announces-space-enterprise-vision/). The SEV addresses increasing threats to space-related systems. The vision includes an integrated approach across all mission areas (communications, positioning, navigation and timing, missile warning, and weather data) and emphasizes improved access to data across the entire enterprise and the ability to protect space-related assets and capabilities. "The future space enterprise will maintain our nation's ability to deliver critical space effects throughout all phases of conflict," Hyten said. Satellite telemetry is going to become available to a new audience. While that telemetry information should be valuable for achieving Space Situational Awareness (SSA), these new satellite telemetry data consumers will not know how to utilize it. We were tasked with applying AI techniques to build an infrastructure to process satellite telemetry into higher abstraction level symbolic space situational awareness and to initially populate that infrastructure with useful data analysis methods. We are working with two organizations, Montana State University (MSU) and the Air Force Academy, both of whom control satellites and therefore currently analyze satellite telemetry to assess the health and circumstances of their satellites. The design which has resulted from our knowledge elicitation and cognitive task analysis is a hybrid approach which combines symbolic processing techniques of Case-Based Reasoning (CBR) and Behavior Transition Networks (BTNs) with current Machine Learning approaches. BTNs are used to represent the process and associated formulas to check telemetry values against anticipated problems and issues. CBR is used to represent and retrieve BTNs that represent an investigative process that should be applied to the telemetry in certain circumstances. Machine Learning is used to learn normal patterns of telemetry, learn pre-mission simulated telemetry patterns that represent known problems, and detect both pre-trained known and unknown abnormalities in real-time. The operational system is currently being implemented and applied to real satellite telemetry data. This paper presents the design, examples, and results of the first version as well as planned future work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patrick O'Neill
This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested onmore » two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests. This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was necessarily dependent on the others. This resulted in a challenging management task - requiring high bandwidth communications among all the team members. Fortunately, the project team performed exceptionally well together and was able to work through the various challenges that this presented - for example, when one software tool required a detailed description of the output of a second tool, before that tool had been fully designed.« less
Animal movement constraints improve resource selection inference in the presence of telemetry error
Brost, Brian M.; Hooten, Mevin B.; Hanks, Ephraim M.; Small, Robert J.
2016-01-01
Multiple factors complicate the analysis of animal telemetry location data. Recent advancements address issues such as temporal autocorrelation and telemetry measurement error, but additional challenges remain. Difficulties introduced by complicated error structures or barriers to animal movement can weaken inference. We propose an approach for obtaining resource selection inference from animal location data that accounts for complicated error structures, movement constraints, and temporally autocorrelated observations. We specify a model for telemetry data observed with error conditional on unobserved true locations that reflects prior knowledge about constraints in the animal movement process. The observed telemetry data are modeled using a flexible distribution that accommodates extreme errors and complicated error structures. Although constraints to movement are often viewed as a nuisance, we use constraints to simultaneously estimate and account for telemetry error. We apply the model to simulated data, showing that it outperforms common ad hoc approaches used when confronted with measurement error and movement constraints. We then apply our framework to an Argos satellite telemetry data set on harbor seals (Phoca vitulina) in the Gulf of Alaska, a species that is constrained to move within the marine environment and adjacent coastlines.
Bacheler, N.M.; Buckel, J.A.; Hightower, J.E.; Paramore, L.M.; Pollock, K.H.
2009-01-01
A joint analysis of tag return and telemetry data should improve estimates of mortality rates for exploited fishes; however, the combined approach has thus far only been tested in terrestrial systems. We tagged subadult red drum (Sciaenops ocellatus) with conventional tags and ultrasonic transmitters over 3 years in coastal North Carolina, USA, to test the efficacy of the combined telemetry - tag return approach. There was a strong seasonal pattern to monthly fishing mortality rate (F) estimates from both conventional and telemetry tags; highest F values occurred in fall months and lowest levels occurred during winter. Although monthly F values were similar in pattern and magnitude between conventional tagging and telemetry, information on F in the combined model came primarily from conventional tags. The estimated natural mortality rate (M) in the combined model was low (estimated annual rate ?? standard error: 0.04 ?? 0.04) and was based primarily upon the telemetry approach. Using high-reward tagging, we estimated different tag reporting rates for state agency and university tagging programs. The combined telemetry - tag return approach can be an effective approach for estimating F and M as long as several key assumptions of the model are met.
Korstanje, Ron; Ryan, Jennifer L; Savage, Holly S; Lyons, Bonnie L; Kane, Kevin G; Sukoff Rizzo, Stacey J
2017-09-01
Previous studies with continuous glucose monitoring in mice have been limited to several days or weeks, with the mouse's physical attachment to the equipment affecting behavior and measurements. In the current study, we measured blood glucose and body temperature at 10-second intervals for 12 weeks in a cohort of NOD/ShiLtJ female mice using wireless telemetry. This allowed us to obtain a high-resolution profile of the circadian rhythm of these two parameters and the onset of hyperglycemic development in real time. The most striking observations were the elevated nocturnal concentrations of glucose into the diabetic range days before elevations in diurnal glucose (when glucose concentrations are historically measured) and the strong, negative correlation between elevated blood glucose concentrations and body temperature with a steady decline of the body temperature with diabetes development. Taken together, this technological advancement provides improved resolution in the study of the disease trajectory of diabetes in mouse models, including relevant translatability to the current technologies of continuous glucose monitoring now regularly used in patients. Copyright © 2017 Endocrine Society.
Mehmood, Nasir; Hariz, Alex; Templeton, Sue; Voelcker, Nicolas H
2014-11-18
This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management. The system is fabricated on a 0.2 mm thick flexible printed circuit material, and is capable of sensing pressure and moisture at two locations simultaneously within a compression bandage and wound dressing. The sensors are calibrated to sense both parameters accurately, and the data are then transmitted wirelessly to a receiver connected to a mobile device. An error-correction algorithm is developed to compensate the degradation in measurement quality due to battery power drop over time. An Android application is also implemented to automatically receive, process, and display the sensed wound parameters. The performance of the sensing system is first validated on a mannequin limb using a compression bandage and wound dressings, and then tested on a healthy volunteer to acquire real-time performance parameters. The results obtained here suggest that this dual mode sensor can perform reliably when placed on a human limb.
Mehmood, Nasir; Hariz, Alex; Templeton, Sue; Voelcker, Nicolas H.
2014-01-01
This paper presents the development of an improved mobile-based telemetric dual mode sensing system to monitor pressure and moisture levels in compression bandages and dressings used for chronic wound management. The system is fabricated on a 0.2 mm thick flexible printed circuit material, and is capable of sensing pressure and moisture at two locations simultaneously within a compression bandage and wound dressing. The sensors are calibrated to sense both parameters accurately, and the data are then transmitted wirelessly to a receiver connected to a mobile device. An error-correction algorithm is developed to compensate the degradation in measurement quality due to battery power drop over time. An Android application is also implemented to automatically receive, process, and display the sensed wound parameters. The performance of the sensing system is first validated on a mannequin limb using a compression bandage and wound dressings, and then tested on a healthy volunteer to acquire real-time performance parameters. The results obtained here suggest that this dual mode sensor can perform reliably when placed on a human limb. PMID:25412216
Toward a reduced-wire readout system for ultrasound imaging.
Lim, Jaemyung; Arkan, Evren F; Degertekin, F Levent; Ghovanloo, Maysam
2014-01-01
We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply.
Automating CapCom Using Mobile Agents and Robotic Assistants
NASA Technical Reports Server (NTRS)
Clancey, William J.; Sierhuis, Maarten; Alena, Richard L.; Graham, Jeffrey S.; Tyree, Kim S.; Hirsh, Robert L.; Garry, W. Brent; Semple, Abigail; Shum, Simon J. Buckingham; Shadbolt, Nigel;
2007-01-01
Mobile Agents (MA) is an advanced Extra-Vehicular Activity (EVA) communications and computing system to increase astronaut self-reliance and safety, reducing dependence on continuous monitoring and advising from mission control on Earth. MA is voice controlled and provides information verbally to the astronauts through programs called "personal agents." The system partly automates the role of CapCom in Apollo-including monitoring and managing navigation, scheduling, equipment deployment, telemetry, health tracking, and scientific data collection. Data are stored automatically in a shared database in the habitat/vehicle and mirrored to a site accessible by a remote science team. The program has been developed iteratively in authentic work contexts, including six years of ethnographic observation of field geology. Analog field experiments in Utah enabled empirically discovering requirements and testing alternative technologies and protocols. We report on the 2004 system configuration, experiments, and results, in which an EVA robotic assistant (ERA) followed geologists approximately 150 m through a winding, narrow canyon. On voice command, the ERA took photographs and panoramas and was directed to serve as a relay on the wireless network.
Toward a Reduced-Wire Readout System for Ultrasound Imaging
Lim, Jaemyung; Arkan, Evren F.; Degertekin, F. Levent; Ghovanloo, Maysam
2015-01-01
We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply. PMID:25571135
High temperature, harsh environment sensors for advanced power generation systems
NASA Astrophysics Data System (ADS)
Ohodnicki, P. R.; Credle, S.; Buric, M.; Lewis, R.; Seachman, S.
2015-05-01
One mission of the Crosscutting Technology Research program at the National Energy Technology Laboratory is to develop a suite of sensors and controls technologies that will ultimately increase efficiencies of existing fossil-fuel fired power plants and enable a new generation of more efficient and lower emission power generation technologies. The program seeks to accomplish this mission through soliciting, managing, and monitoring a broad range of projects both internal and external to the laboratory which span sensor material and device development, energy harvesting and wireless telemetry methodologies, and advanced controls algorithms and approaches. A particular emphasis is placed upon harsh environment sensing for compatibility with high temperature, erosive, corrosive, and highly reducing or oxidizing environments associated with large-scale centralized power generation. An overview of the full sensors and controls portfolio is presented and a selected set of current and recent research successes and on-going projects are highlighted. A more detailed emphasis will be placed on an overview of the current research thrusts and successes of the in-house sensor material and device research efforts that have been established to support the program.
Zheng, Qi; Xiong, Lei; Mo, Bing; Lu, Weihong; Kim, Suki; Wang, Zhenyu
2015-09-11
Microbial fuel cells (MFCs) are of increasing interest as bioelectrochemical systems for decomposing organic materials and converting chemical energy into electricity. The main challenge for this technology is that the low power and voltage of the devices restricts the use of MFCs in practical applications. In this paper, a power management system (PMS) is developed to store the energy and export an increased voltage. The designed PMS successfully increases the low voltage generated by an individual MFC to a high potential of 5 V, capable of driving a wireless temperature and humidity sensor based on nRF24L01 data transmission modules. With the PMS, MFCs can intermittently power the sensor for data transmission to a remote receiver. It is concluded that even an individual MFC can supply the energy required to power the sensor and telemetry system with the designed PMS. The presented PMS can be widely used for unmanned environmental monitoring such as wild rivers, lakes, and adjacent water areas, and offers promise for further advances in MFC technology.
Zheng, Qi; Xiong, Lei; Mo, Bing; Lu, Weihong; Kim, Suki; Wang, Zhenyu
2015-01-01
Microbial fuel cells (MFCs) are of increasing interest as bioelectrochemical systems for decomposing organic materials and converting chemical energy into electricity. The main challenge for this technology is that the low power and voltage of the devices restricts the use of MFCs in practical applications. In this paper, a power management system (PMS) is developed to store the energy and export an increased voltage. The designed PMS successfully increases the low voltage generated by an individual MFC to a high potential of 5 V, capable of driving a wireless temperature and humidity sensor based on nRF24L01 data transmission modules. With the PMS, MFCs can intermittently power the sensor for data transmission to a remote receiver. It is concluded that even an individual MFC can supply the energy required to power the sensor and telemetry system with the designed PMS. The presented PMS can be widely used for unmanned environmental monitoring such as wild rivers, lakes, and adjacent water areas, and offers promise for further advances in MFC technology. PMID:26378546
Normann, R.A.; Kadlec, E.R.
1994-11-08
A downhole telemetry system is described for optically communicating to the surface operating parameters of a drill bit during ongoing drilling operations. The downhole telemetry system includes sensors mounted with a drill bit for monitoring at least one operating parameter of the drill bit and generating a signal representative thereof. The downhole telemetry system includes means for transforming and optically communicating the signal to the surface as well as means at the surface for producing a visual display of the optically communicated operating parameters of the drill bit. 7 figs.
Normann, Randy A.; Kadlec, Emil R.
1994-01-01
A downhole telemetry system is described for optically communicating to the surface operating parameters of a drill bit during ongoing drilling operations. The downhole telemetry system includes sensors mounted with a drill bit for monitoring at least one operating parameter of the drill bit and generating a signal representative thereof. The downhole telemetry system includes means for transforming and optically communicating the signal to the surface as well as means at the surface for producing a visual display of the optically communicated operating parameters of the drill bit.
Evolution of the LBT Telemetry System
NASA Astrophysics Data System (ADS)
Summers, K.; Biddick, C.; De La Peña, M. D.; Summers, D.
2014-05-01
The Large Binocular Telescope (LBT) Telescope Control System (TCS) records about 10GB of telemetry data per night. Additionally, the vibration monitoring system records about 9GB of telemetry data per night. Through 2013, we have amassed over 6TB of Hierarchical Data Format (HDF5) files and almost 9TB in a MySQL database of TCS and vibration data. The LBT telemetry system, in its third major revision since 2004, provides the mechanism to capture and store this data. The telemetry system has evolved from a simple HDF file system with MySQL stream definitions within the TCS, to a separate system using a MySQL database system for the definitions and data, and finally to no database use at all, using HDF5 files.
Macintosh II based space Telemetry and Command (MacTac) system
NASA Technical Reports Server (NTRS)
Dominy, Carol T.; Chesney, James R.; Collins, Aaron S.; Kay, W. K.
1991-01-01
The general architecture and the principal functions of the Macintosh II based Telemetry and Command system, presently under development, are described, with attention given to custom telemetry cards, input/output interfaces, and the icon driven user interface. The MacTac is a low-cost, transportable, easy to use, compact system designed to meet the requirements specified by the Consultative Committeee for Space Data Systems while remaining flexible enough to support a wide variety of other user specific telemetry processing requirements, such as TDM data. In addition, the MacTac can accept or generate forward data (such as spacecraft commands), calculate and append a Polynomial Check Code, and output these data to NASCOM to provide full Telemetry and Command capability.
Telemetry Simulation Assembly Implementation in the DSN
NASA Technical Reports Server (NTRS)
Alberda, M. E.
1984-01-01
The telemetry simulation was implemented as part of the MARK IV network implementation project. The telemetry simulation assembly (TSA) is replacing the Simulation Conversion Assembly (SCA) throughout the DSN. The development of the TSA is discussed, and the design is described to the block diagram level.
Reliable intraocular pressure measurement using automated radio-wave telemetry
Paschalis, Eleftherios I; Cade, Fabiano; Melki, Samir; Pasquale, Louis R; Dohlman, Claes H; Ciolino, Joseph B
2014-01-01
Purpose To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. Methods The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline) IOP. Results On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg) and mean vehicle IOP (13.27±2.1 mmHg) (P=0.45), suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001), and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001). Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001). Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute), during which the IOP is not expected to change. Conclusion IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results. PMID:24531415
Biomedical sensor design using analog compressed sensing
NASA Astrophysics Data System (ADS)
Balouchestani, Mohammadreza; Krishnan, Sridhar
2015-05-01
The main drawback of current healthcare systems is the location-specific nature of the system due to the use of fixed/wired biomedical sensors. Since biomedical sensors are usually driven by a battery, power consumption is the most important factor determining the life of a biomedical sensor. They are also restricted by size, cost, and transmission capacity. Therefore, it is important to reduce the load of sampling by merging the sampling and compression steps to reduce the storage usage, transmission times, and power consumption in order to expand the current healthcare systems to Wireless Healthcare Systems (WHSs). In this work, we present an implementation of a low-power biomedical sensor using analog Compressed Sensing (CS) framework for sparse biomedical signals that addresses both the energy and telemetry bandwidth constraints of wearable and wireless Body-Area Networks (BANs). This architecture enables continuous data acquisition and compression of biomedical signals that are suitable for a variety of diagnostic and treatment purposes. At the transmitter side, an analog-CS framework is applied at the sensing step before Analog to Digital Converter (ADC) in order to generate the compressed version of the input analog bio-signal. At the receiver side, a reconstruction algorithm based on Restricted Isometry Property (RIP) condition is applied in order to reconstruct the original bio-signals form the compressed bio-signals with high probability and enough accuracy. We examine the proposed algorithm with healthy and neuropathy surface Electromyography (sEMG) signals. The proposed algorithm achieves a good level for Average Recognition Rate (ARR) at 93% and reconstruction accuracy at 98.9%. In addition, The proposed architecture reduces total computation time from 32 to 11.5 seconds at sampling-rate=29 % of Nyquist rate, Percentage Residual Difference (PRD)=26 %, Root Mean Squared Error (RMSE)=3 %.
Development and Flight Testing of an Adaptive Vehicle Health-Monitoring Architecture
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Taylor, B. Douglas; Brett, Rube R.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.
2002-01-01
On going development and testing of an adaptable vehicle health-monitoring architecture is presented. The architecture is being developed for a fleet of vehicles. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle, and, a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained expert system. The expert system is parameterized, which makes it adaptable to be trained to both a user's subject reasoning and existing quantitative analytic tools. Communication between all levels is done with wireless radio frequency interfaces. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear. The flight tests were performed to validate the following: the wireless radio frequency communication capabilities of the system, the hardware design, command and control; software operation and, data acquisition, storage and retrieval.
Prototype Software for Future Spaceflight Tested at Mars Desert Research Station
NASA Technical Reports Server (NTRS)
Clancey, William J.; Sierhuis, Maaretn; Alena, Rick; Dowding, John; Garry, Brent; Scott, Mike; Tompkins, Paul; vanHoof, Ron; Verma, Vandi
2006-01-01
NASA scientists in MDRS Crew 49 (April 23-May 7, 2006) field tested and significantly extended a prototype monitoring and advising system that integrates power system telemetry with a voice commanding interface. A distributed, wireless network of functionally specialized agents interacted with the crew to provide alerts (e.g., impending shut-down of inverter due to low battery voltage), access md interpret historical data, and display troubleshooting procedures. In practical application during two weeks, the system generated speech over loudspeakers and headsets lo alert the crew about the need to investigate power system problems. The prototype system adapts the Brahms/Mobile Agents toolkit to receive data from the OneMeter (Brand Electronics) electric metering system deployed by Crew 47. A computer on the upper deck was connected to loudspeakers, four others were paired with wireless (Bluetooth) headsets that enabled crew members to interact with their personal agents from anywhere in the hab. Voice commands and inquiries included: 1. What is the {battery | generator} {volts | amps | volts and amps}? 2. What is the status of the {generator | inverter | battery | solar panel}? 3. What is the hab{itat} {power usage | volts | voltage | amps | volts and amps}? 4. What was the average hab{itat} {amps | volts | voltage} since <#> {AM | PM)? 5. When did the {generator | batteries} change status? 6. Tell {me I
Preliminary PANSAT ground station software design and use of an expert system to analyze telemetry
NASA Astrophysics Data System (ADS)
Lawrence, Gregory W.
1994-03-01
The Petite Amateur Navy Satellite (PANSAT) is a communications satellite designed to be used by civilian amateur radio operators. A master ground station is being built at the Naval Postgraduate School. This computer system performs satellite commands, displays telemetry, trouble-shoots problems, and passes messages. The system also controls an open loop tracking antenna. This paper concentrates on the telemetry display, decoding, and interpretation through artificial intelligence (AI). The telemetry is displayed in an easily interpretable format, so that any user can understand the current health of the satellite and be cued as to any problems and possible solutions. Only the master ground station has the ability to receive all telemetry and send commands to the spacecraft; civilian ham users do not have access to this information. The telemetry data is decommutated and analyzed before it is displayed to the user, so that the raw data will not have to be interpreted by ground users. The analysis will use CLIPS imbedded in the code, and derive its inputs from telemetry decommutation. The program is an expert system using a forward chaining set of rules based on the expected operation and parameters of the satellite. By building the rules during the construction and design of the satellite, the telemetry can be well understood and interpreted after the satellite is launched and the designers may no longer be available to provide input to the problem.
DSN telemetry system data records
NASA Technical Reports Server (NTRS)
Gatz, E. C.
1976-01-01
The DSN telemetry system now includes the capability to provide a complete magnetic tape record, within 24 hours of reception, of all telemetry data received from a spacecraft. This record, the intermediate data record, is processed and generated almost entirely automatically, and provides a detailed accounting of any missing data.
Impedance-matched drilling telemetry system
Normann, Randy A [Edgewood, NM; Mansure, Arthur J [Albuquerque, NM
2008-04-22
A downhole telemetry system that uses inductance or capacitance as a mode through which signal is communicated across joints between assembled lengths of pipe wherein efficiency of signal propagation through a drill string, for example, over multiple successive pipe segments is enhanced through matching impedances associated with the various telemetry system components.
106-17 Telemetry Standards Metadata Configuration Chapter 23
2017-07-01
23-1 23.2 Metadata Description Language ...Chapter 23, July 2017 iii Acronyms HTML Hypertext Markup Language MDL Metadata Description Language PCM pulse code modulation TMATS Telemetry...Attributes Transfer Standard W3C World Wide Web Consortium XML eXtensible Markup Language XSD XML schema document Telemetry Network Standard
47 CFR 90.238 - Telemetry operations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MHz band (as available in the Public Safety Pool for bio-medical telemetry operations). (i) For... with § 90.257 and subject to the rules governing the use of that band). (b) 154.45625, 154.46375, 154...-470 MHz band, telemetry operations will be authorized on a secondary basis with a transmitter output...
2017-07-13
ec o n d s Data Rate TELEMETRY SYSTEM DATA LATENCY 15 of 31 Document: JT3-AFC-SRPT-17172-0005 Revision...250 So ft w ar e D ec o m L at en cy N T im es G re at er T h an D xD ec o m L at en cy Data Rate TELEMETRY SYSTEM DATA LATENCY 16 of...20.0 30.0 40.0 50.0 60.0 70.0 M ill is ec o n d s Data Rate TELEMETRY SYSTEM DATA LATENCY 17 of 31 Document:
Satellite telemetry and wildlife studies in India: Advantages, options and challenges
Javed, Sàlim; Higuchi, Hiroyoshi; Nagendran, Meenakshi; Takekawa, John Y.
2003-01-01
Greater spatial coverage, accuracy and non-invasiveness of satellite technology make it one of the best tools to track long-distance migrants, which is otherwise difficult using conventional radio telemetry. In this article, we review the evolution of satellite telemetry and its application. We provide examples of three recent studies in India that have demonstrated and created a widespread appreciation of the use and benefits of satellite telemetry among biologists and managers. We also discuss the future prospects of this technology vis-a-vis benefits and challenges in the Indian subcontinent.
NASA Technical Reports Server (NTRS)
1997-01-01
In 1990, Avtec Systems, Inc. developed its first telemetry boards for Goddard Space Flight Center. Avtec products now include PC/AT, PCI and VME-based high speed I/O boards and turn-key systems. The most recent and most successful technology transfer from NASA to Avtec is the Programmable Telemetry Processor (PTP), a personal computer- based, multi-channel telemetry front-end processing system originally developed to support the NASA communication (NASCOM) network. The PTP performs data acquisition, real-time network transfer, and store and forward operations. There are over 100 PTP systems located in NASA facilities and throughout the world.
Director, Operational Test and Evaluation Report FY
1989-01-19
FIRST QUARTER, FY89 ........... VII-I GLOSSARY OF ACRONYMS ....................................... G -1 0 0 0 * vii "* PART I DOT&E ACTIVITY SUMMARY AAND...ouiteriawere egoiandtion w oit e form sisted of the approved air threat against ahecriteria wer expanded to pr vide ora g fruntsiltdnce iog- more...COMMUNICATIONS TERMINAL-- ~~AN/TRC-179(V)1 ,. S(FORCE-MOBILE) MANPACK P/O AN/GRC-215 GENERATOR SET PU-794/ G (MOD) * COMMUNICATIONS TERMINAL AN/GRC-215 AN
Adaption of Machine Fluid Analysis for Manufacturing - Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pardini, Allan F.
2005-08-16
Pacific Northwest National Laboratory (PNNL: Operated by Battelle Memorial Institute for the Department of Energy) is working with the Department of Energy (DOE) to develop technology for the US mining industry. Filtration and lubricant suppliers to the pulp and paper industry had noted the recent accomplishments by PNNL and its industrial partners in the DOE OIT Mining Industry of the Future Program, and asked for assistance in adapting this DOE-funded technology to the pulp and paper industry.
Evaluating elk habitat interactions with GPS collars
Mark A. Rumble; Lakhdar Benkobi; Fredrick Lindzey; R. Scott Gamo
2001-01-01
Global positioning systems (GPS) are likely to revolutionize animal telemetry studies. GPS collars allow biologists to collect systematically scheduled data when VHF telemetry data is difficult or impossible to collect. Past studies have shown that the success of GPS telemetry is greater when animals are standing, or in open habitats. To make effective use of GPS...
A graphic system for telemetry monitoring and procedure performing at the Telecom SCC
NASA Technical Reports Server (NTRS)
Loubeyre, Jean Philippe
1994-01-01
The increasing amount of telemetry parameters and the increasing complexity of procedures used for the in-orbit satellite follow-up has led to the development of new tools for telemetry monitoring and procedures performing. The name of the system presented here is Graphic Server. It provides an advanced graphic representation of the satellite subsystems, including real-time telemetry and alarm displaying, and a powerful help for decision making with on line contingency procedures. Used for 2.5 years at the TELECOM S.C.C. for procedure performing, it has become an essential part of the S.C.C.
Experience with the EURECA Packet Telemetry and Packet Telecommand system
NASA Technical Reports Server (NTRS)
Sorensen, Erik Mose; Ferri, Paolo
1994-01-01
The European Retrieval Carrier (EURECA) was launched on its first flight on the 31st of July 1992 and retrieved on the 29th of June 1993. EURECA is characterized by several new on-board features, most notably Packet telemetry, and a partial implementation of packet telecommanding, the first ESA packetised spacecraft. Today more than one year after the retrieval the data from the EURECA mission has to a large extent been analysed and we can present some of the interesting results. This paper concentrates on the implementation and operational experience with the EURECA Packet Telemetry and Packet Telecommanding. We already discovered during the design of the ground system that the use of packet telemetry has major impact on the overall design and that processing of packet telemetry may have significant effect on the computer loading and sizing. During the mission a number of problems were identified with the on-board implementation resulting in very strange anomalous behaviors. Many of these problems directly violated basic assumptions for the design of the ground segment adding to the strange behavior. The paper shows that the design of a telemetry packet system should be flexible enough to allow a rapid configuration of the telemetry processing in order to adapt it to the new situation in case of an on-board failure. The experience gained with the EURECA mission control should be used to improve ground systems for future missions.
Comprehension of Spacecraft Telemetry Using Hierarchical Specifications of Behavior
NASA Technical Reports Server (NTRS)
Havelund, Klaus; Joshi, Rajeev
2014-01-01
A key challenge in operating remote spacecraft is that ground operators must rely on the limited visibility available through spacecraft telemetry in order to assess spacecraft health and operational status. We describe a tool for processing spacecraft telemetry that allows ground operators to impose structure on received telemetry in order to achieve a better comprehension of system state. A key element of our approach is the design of a domain-specific language that allows operators to express models of expected system behavior using partial specifications. The language allows behavior specifications with data fields, similar to other recent runtime verification systems. What is notable about our approach is the ability to develop hierarchical specifications of behavior. The language is implemented as an internal DSL in the Scala programming language that synthesizes rules from patterns of specification behavior. The rules are automatically applied to received telemetry and the inferred behaviors are available to ground operators using a visualization interface that makes it easier to understand and track spacecraft state. We describe initial results from applying our tool to telemetry received from the Curiosity rover currently roving the surface of Mars, where the visualizations are being used to trend subsystem behaviors, in order to identify potential problems before they happen. However, the technology is completely general and can be applied to any system that generates telemetry such as event logs.
GROVER: An autonomous vehicle for ice sheet research
NASA Astrophysics Data System (ADS)
Trisca, G. O.; Robertson, M. E.; Marshall, H.; Koenig, L.; Comberiate, M. A.
2013-12-01
The Goddard Remotely Operated Vehicle for Exploration and Research or Greenland Rover (GROVER) is a science enabling autonomous robot specifically designed to carry a low-power, large bandwidth radar for snow accumulation mapping over the Greenland Ice Sheet. This new and evolving technology enables reduced cost and increased safety for polar research. GROVER was field tested at Summit, Greenland in May 2013. The robot traveled over 30 km and was controlled both by line of sight wireless and completely autonomously with commands and telemetry via the Iridium Satellite Network, from Summit as well as remotely from Boise, Idaho. Here we describe GROVER's unique abilities and design. The software stack features a modular design that can be adapted for any application that requires autonomous behavior, reliable communications using different technologies and low level control of peripherals. The modules are built to communicate using the publisher-subscriber design pattern to maximize data-reuse and allow for graceful failures at the software level, along with the ability to be loaded or unloaded on-the-fly, enabling the software to adopt different behaviors based on power constraints or specific processing needs. These modules can also be loaded or unloaded remotely for servicing and telemetry can be configured to contain any kind of information being generated by the sensors or scientific instruments. The hardware design protects the electronic components and the control system can change functional parameters based on sensor input. Power failure modes built into the hardware prevent the vehicle from running out of energy permanently by monitoring voltage levels and triggering software reboots when the levels match pre-established conditions. This guarantees that the control software will be operational as soon as there is enough charge to sustain it, giving the vehicle increased longevity in case of a temporary power loss. GROVER demonstrates that autonomous rovers can be a revolutionary tool for data collection, and that both the technology and the software are available and ready to be implemented to create scientific data collection platforms.
Keeping Communication Continuous
NASA Technical Reports Server (NTRS)
2003-01-01
General Dynamics Decision Systems employees have played a role in supplying telemetry, tracking, and control (TT&C) and other communications systems to NASA and the U.S. Department of Defense for over 40 years. Providing integrated communication systems and subsystems for nearly all manned and unmanned U.S. space flights, the heritage of this Scottsdale, Arizona-based company includes S-band transceivers that enabled millions of Americans to see Neil Armstrong and hear his prophetic words from the Moon in 1969. More recently, Decision Systems has collaborated with NASA s Goddard Space Flight Center to develop transponders, wireless communications devices that pick up and automatically respond to an incoming signal, for NASA s Tracking and Data Relay Satellite System (TDRSS). Four generations of Decision Systems TDRSS transponders have been developed under Goddard s sponsorship. The company s Fourth Generation TDRSS User Transponder (TDRSS IV) allows low-Earth-orbiting spacecraft to communicate continuously with a single ground station at White Sands, New Mexico, through a constellation of geostationary relay satellites positioned at key locations around the Earth. In addition to the communications of forward link control commands and return link telemetry data, the TDRSS IV also supports spacecraft orbit tracking through coherent turn-around of a pseudo-noise ranging code and two-way Doppler tracking.When the NSBF adopted the use of global positioning system receivers for balloon position tracking, Decision Systems concluded that a simpler, noncoherent transceiver could provide the NSBF with the necessary TDRSS communications without the additional cost and complexity of a coherent transponder. The solution was to take the core design of the TDRSS IV Transponder, but remove the extra functionality that supported coherent turn-around. This would simplify the production effort, reduce the testing required, and result in a lower cost product with smaller size, weight, and power consumption. Once NSBF and Decision Systems agreed on a concept for this new product, known as the Multi-Mode Transceiver (MMT), the NSBF approached Goddard for approval and funding.
Radio telemetry methods for studying spotted owls in the Pacific Northwest.
J.H. Guetterman; J.A. Burns; J.A. Reid; R.B. Horn; C.C. Foster
1991-01-01
The paper is a practical guide to field methodology for conducting a radio telemetry study of spotted owls (Strix occidentalis) in mountainous terrain. It begins with a synopsis of spotted owl biology and basic telemetry. The criteria used to select which owls will carry transmitters are discussed as are location and capture methods. Instructions...
75 FR 19277 - PLMR Licensing; Frequency Coordination and Eligibility Issues
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-14
... band (1427-1429.5 MHz), and non-medical telemetry in the upper half of the band (1429.5-1432 MHz). Non... secondary basis on those portions of the 1427-1432 MHz shared band where non-medical telemetry is primary...-medical telemetry has primary status. Some WMTS operations in the portions of the 1427-1432 MHz band where...
DSN telemetry system performance with convolutionally code data
NASA Technical Reports Server (NTRS)
Mulhall, B. D. L.; Benjauthrit, B.; Greenhall, C. A.; Kuma, D. M.; Lam, J. K.; Wong, J. S.; Urech, J.; Vit, L. D.
1975-01-01
The results obtained to date and the plans for future experiments for the DSN telemetry system were presented. The performance of the DSN telemetry system in decoding convolutionally coded data by both sequential and maximum likelihood techniques is being determined by testing at various deep space stations. The evaluation of performance models is also an objective of this activity.
2008-02-01
inclusions fi-rm a recently discovered high ’He/ 4 H the ielt source but that is not detectable in whole basalt from Samoa [25]. Our strategy is to...can compare: canl be inferred fi-om the neat-uniforma ratios obtained thlem to similarly corrected Samoan whole-rock lavas oit) ielt inclusijons from...Rb correction. Although the number,ftlataluintsis limited, the data are consistent 3.2. Major and frace element characteristics /i mwlt with Ielt
2012-09-01
Am. 2004; 86(5):1092-1095. 8. Gelfand DV, Podnos YD, Carmichael JC, Saltzman DJ, Wilson SE, Williams RA. Effect of the 80- hour workweek on...burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing...American Academy of Orthopaedic Surgeons (AAOS) since 1963.1 The 4 goals of the OITE, as described by Mankin,2 are to: (1) help graduating
AFRRI (Armed Forces Radiobiology Research Institute) Reports, July, August, September 1989.
1989-11-01
ippticatnpusit Maged. ineintr -det ic tent rat’ J tier oit l 3 3, Bank ,. W J. Hisiiilig% and citinparati.e tirganilig% A te’. atlas 31-12. 11)...concentrations of Leu-Leu-OMe (Tbl 1). Mini- he euthanized on day 19 posttransplant due to an accidental, mal CFt ,-(NI growth was observed with 10’ Leu-leu...phospholipid which provides the arachidlonic acid required for syn- veilswtth rgana m baeealsteacvtdga- thesis of prostaglandins and other eicosanoids (1-5
Navy’s Advanced Aircraft Armament System Program Concept Objectives
1983-10-01
12-1 00 NAVY’S ADVANCED AIRCRAFT ARMAMENT SYSTEM PROGRAM CONCEPT OBJECTIVES T. M . Leese and J. F. Haney Naval Weapons Center Code 31403 China...STORE FLWNT LIFE RECONFIOURATION ♦ UWMST OMHTH ninoairv M — MANN HUCTHM ^♦■ SILECT ALTERNATE • STORE 0PTI0M ■ REOUCIO CK« W0RKL0A0 • . README...mOVEMENTS INÜTEO FUIWUTY MM AM tTATWM COMPLEX AUTOMATIC LACK OF OIT RESTRICTIVE MLNIRV M FLUWAITV IUCSMVI Figure 1. Carrier aircraft
Active Probing of Space Plasmas
1989-09-01
ft. shuttle wake mlay also a kect the optration (if mi’:nc di.tg. Ibk Prwwattr of ,frttirw 844 I. %rvaom ’itbi h" $od iy radlet 6va of IkeA dtm t...probe had a specially designed inner shaft caused by the existence of some ballistic electrons after made with .pring sleel tubing. By externally...potential to the electron thermal energy i(s distances downstream of the body (see Fig. 1). This (e OIT,) was on the order of 10 in steady state. design
Can telemetry data obviate the need for sleep studies in Pierre Robin Sequence?
Aaronson, Nicole Leigh; Jabbour, Noel
2017-09-01
This study looks to correlate telemetry data gathered on patients with Pierre Robin Sequence (PRS) with sleep study data. Strong correlation might allow obstructive sleep apnea (OSA) to be reasonably predicted without the need for sleep study. Charts from forty-six infants with PRS who presented to our children's hospital between 2005 and 2015 and received a polysomnogram (PSG) prior to surgical intervention were retrospectively reviewed. Correlations and scatterplots were used to compare average daily oxygen nadir, overall oxygen nadir, and average number of daily desaturations from telemetry data with apnea-hypopnea index (AHI) and oxygen nadir on sleep study. Results were also categorized into groups of AHI ≥ or <10 and oxygen nadir ≥ or <80% for chi-squared analysis. Our data did not show significant correlations between telemetry data and sleep study data. Patients with O2 nadir below 80% on telemetry were not more likely to have an O2 nadir below 80% on sleep study. Patients with an average O2 nadir below 80% did show some correlation with having an AHI greater than 10 on sleep study but this relationship did not reach significance. Of 22 patients who did not have any desaturations on telemetry below 80%, 16 (73%) had an AHI >10 on sleep study. In the workup of infants with PRS, the index of suspicion is high for OSA. In our series, telemetry data was not useful in ruling out severe OSA. Thus our data do not support forgoing sleep study in patients with PRS and concern for OSA despite normal telemetry patterns. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Guy, Nathaniel
This thesis explores new ways of looking at telemetry data, from a time-correlative perspective, in order to see patterns within the data that may suggest root causes of system faults. It was thought initially that visualizing an animated Pearson Correlation Coefficient (PCC) matrix for telemetry channels would be sufficient to give new understanding; however, testing showed that the high dimensionality and inability to easily look at change over time in this approach impeded understanding. Different correlative techniques, combined with the time curve visualization proposed by Bach et al (2015), were adapted to visualize both raw telemetry and telemetry data correlations. Review revealed that these new techniques give insights into the data, and an intuitive grasp of data families, which show the effectiveness of this approach for enhancing system understanding and assisting with root cause analysis for complex aerospace systems.
Definition and maintenance of a telemetry database dictionary
NASA Technical Reports Server (NTRS)
Knopf, William P. (Inventor)
2007-01-01
A telemetry dictionary database includes a component for receiving spreadsheet workbooks of telemetry data over a web-based interface from other computer devices. Another component routes the spreadsheet workbooks to a specified directory on the host processing device. A process then checks the received spreadsheet workbooks for errors, and if no errors are detected the spreadsheet workbooks are routed to another directory to await initiation of a remote database loading process. The loading process first converts the spreadsheet workbooks to comma separated value (CSV) files. Next, a network connection with the computer system that hosts the telemetry dictionary database is established and the CSV files are ported to the computer system that hosts the telemetry dictionary database. This is followed by a remote initiation of a database loading program. Upon completion of loading a flatfile generation program is manually initiated to generate a flatfile to be used in a mission operations environment by the core ground system.
Phobos lander coding system: Software and analysis
NASA Technical Reports Server (NTRS)
Cheung, K.-M.; Pollara, F.
1988-01-01
The software developed for the decoding system used in the telemetry link of the Phobos Lander mission is described. Encoders and decoders are provided to cover the three possible telemetry configurations. The software can be used to decode actual data or to simulate the performance of the telemetry system. The theoretical properties of the codes chosen for this mission are analyzed and discussed.
Applicability of implantable telemetry systems in cardiovascular research.
NASA Technical Reports Server (NTRS)
Krutz, R. W.; Rader, R. D.; Meehan, J. P.; Henry, J. P.
1971-01-01
This paper briefly describes the results of an experimental program undertaken to develop and apply implanted telemetry to cardiovascular research. Because of the role the kidney may play in essential hypertension, emphasis is placed on telemetry's applicability in the study of renal physiology. Consequently, the relationship between pressure, flow, and hydraulic impedance are stressed. Results of an exercise study are given.
NASA Technical Reports Server (NTRS)
Schneider, Michelle
2003-01-01
This viewgraph representation provides an overview of the Telescience Resource Kit. The Telescience Resource Kit is a pc-based telemetry and command system that will be used by scientists and engineers to monitor and control experiments located on-board the International Space Station (ISS). Topics covered include: ISS Payload Telemetry and Command Flow, kit computer applications, kit telemetry capabilities, command capabilities, and training/testing capabilities.
A Systematic Approach to Error Free Telemetry
2017-06-28
A SYSTEMATIC APPROACH TO ERROR FREE TELEMETRY 412TW-TIM-17-03 DISTRIBUTION A: Approved for public release. Distribution is...Systematic Approach to Error-Free Telemetry) was submitted by the Commander, 412th Test Wing, Edwards AFB, California 93524. Prepared by...Technical Information Memorandum 3. DATES COVERED (From - Through) February 2016 4. TITLE AND SUBTITLE A Systematic Approach to Error-Free
System for Configuring Modular Telemetry Transponders
NASA Technical Reports Server (NTRS)
Varnavas, Kosta A. (Inventor); Sims, William Herbert, III (Inventor)
2014-01-01
A system for configuring telemetry transponder cards uses a database of error checking protocol data structures, each containing data to implement at least one CCSDS protocol algorithm. Using a user interface, a user selects at least one telemetry specific error checking protocol from the database. A compiler configures an FPGA with the data from the data structures to implement the error checking protocol.
Animal Telemetry Network Data Assembly Center: Phase 2
2015-09-30
1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Animal telemetry network data assembly center: Phase...2 Barbara Block & Randy Kochevar Hopkins Marine Station Stanford University 120 Oceanview Blvd. Pacific Grove, Ca phone: (831) 655-6236...prior development for tag data management (e.g. TOPP, GTOPP, GulfTOPP) of animal telemetry data management into a single system (DAC) with an
A Real-Time Telemetry Simulator of the IUS Spacecraft
NASA Technical Reports Server (NTRS)
Drews, Michael E.; Forman, Douglas A.; Baker, Damon M.; Khazoyan, Louis B.; Viazzo, Danilo
1998-01-01
A real-time telemetry simulator of the IUS spacecraft has recently entered operation to train Flight Control Teams for the launch of the AXAF telescope from the Shuttle. The simulator has proven to be a successful higher fidelity implementation of its predecessor, while affirming the rapid development methodology used in its design. Although composed of COTS hardware and software, the system simulates the full breadth of the mission: Launch, Pre-Deployment-Checkout, Burn Sequence, and AXAF/IUS separation. Realism is increased through patching the system into the operations facility to simulate IUS telemetry, Shuttle telemetry, and the Tracking Station link (commands and status message).
LANDSAT-D flight segment operations manual. Appendix B: OBC software operations
NASA Technical Reports Server (NTRS)
Talipsky, R.
1981-01-01
The LANDSAT 4 satellite contains two NASA standard spacecraft computers and 65,536 words of memory. Onboard computer software is divided into flight executive and applications processors. Both applications processors and the flight executive use one or more of 67 system tables to obtain variables, constants, and software flags. Output from the software for monitoring operation is via 49 OBC telemetry reports subcommutated in the spacecraft telemetry. Information is provided about the flight software as it is used to control the various spacecraft operations and interpret operational OBC telemetry. Processor function descriptions, processor operation, software constraints, processor system tables, processor telemetry, and processor flow charts are presented.
Use of radio-telemetry to reduce bias in nest searching
Powell, L.A.; Lang, J.D.; Krementz, D.G.; Conroy, M.J.
2005-01-01
We used traditional searching, as well as radio-telemetry, to find 125 Wood Thrush (Hylocichla mustelina) nests during 1994?1996 at the Piedmont National Wildlife Refuge in Georgia, USA. We compared daily nest survival rates for 66 nests of radio-marked birds with 59 nests of birds found through systematic searching. By using radio-telemetry, we found Wood Thrush nests in higher elevation pine habitats, in addition to the more usual hardwood forests with moist soils. We found nests of radio-marked birds farther from streams than nests found by systematic searching. Thirty-two percent of radio-marked birds' nests were found at the tops of slopes, compared to 15% of the nests found by traditional searching. In addition, radio-marked birds generally moved up-slope for re-nesting attempts. Although the distribution of nests found with telemetry and searching varied, daily nest survival did not vary between the two groups. Radio-telemetry provided new information about Wood Thrush nesting habitats. We believe radio-telemetry can be a valuable addition to traditional searching techniques; it has the potential to provide a sample of nests free from a priori habitat biases.
Evaluation of a GPS used in conjunction with aerial telemetry
Olexa, E.M.; Gogan, P.J.P.; Podruzny, K.M.; Eiler, John; Alcorn, Doris J.; Neuman, Michael R.
2001-01-01
We investigated the use of a non-correctable Global Positioning System (NGPS) in association with aerial telemetry to determine animal locations. Average error was determined for 3 components of the location process: use of a NGPS receiver on the ground, use of a NGPS receiver in a aircraft while flying over a visual marker, and use of the same receiver while flying over a location determined by standard aerial telemetry. Average errors were 45.3, 88.1 and 137.4 m, respectively. A directional bias of <35 m was present for the telemetry component only. Tests indicated that use of NGPS to determine aircraft, and thereby animal, location is an efficient alternative to interpolation from topographic maps. This method was more accurate than previously reported Long-Range Navigation system, version C (LORAN-C) and Argos satellite telemetry. It has utility in areas where animal-borne GPS receivers are not practical due to a combination of topography, canopy coverage, weight or cost of animal-borne GPS units. Use of NGPS technology in conjunction with aerial telemetry will provide the location accuracy required for identification of gross movement patterns and coarse-grained habitat use.
Instrumentation and telemetry systems for free-flight drop model testing
NASA Technical Reports Server (NTRS)
Hyde, Charles R.; Massie, Jeffrey J.
1993-01-01
This paper presents instrumentation and telemetry system techniques used in free-flight research drop model testing at the NASA Langley Research Center. The free-flight drop model test technique is used to conduct flight dynamics research of high performance aircraft using dynamically scaled models. The free-flight drop model flight testing supplements research using computer analysis and wind tunnel testing. The drop models are scaled to approximately 20 percent of the size of the actual aircraft. This paper presents an introduction to the Free-Flight Drop Model Program which is followed by a description of the current instrumentation and telemetry systems used at the NASA Langley Research Center, Plum Tree Test Site. The paper describes three telemetry downlinks used to acquire the data, video, and radar tracking information from the model. Also described are two telemetry uplinks, one used to fly the model employing a ground-based flight control computer and a second to activate commands for visual tracking and parachute recovery of the model. The paper concludes with a discussion of free-flight drop model instrumentation and telemetry system development currently in progress for future drop model projects at the NASA Langley Research Center.
Accuracy of telemetry signal power loss in a filter as an estimate for telemetry degradation
NASA Technical Reports Server (NTRS)
Koerner, M. A.
1989-01-01
When telemetry data is transmitted through a communication link, some degradation in telemetry performance occurs as a result of the imperfect frequency response of the channel. The term telemetry degradation as used here is the increase in received signal power required to offset this filtering. The usual approach to assessing this degradation is to assume that it is equal to the signal power loss in the filtering, which is easily calculated. However, this approach neglects the effects of the nonlinear phase response of the filter, the effect of any reduction of the receiving system noise due to the filter, and intersymbol interference. Here, an exact calculation of the telemetry degradation, which includes all of the above effects, is compared with the signal power loss calculation for RF filtering of NRZ data on a carrier. The signal power loss calculation is found to be a reasonable approximation when the filter follows the point at which the receiving system noise is introduced, especially if the signal power loss is less than 0.5 dB. The signal power loss approximation is less valid when the receiving system noise is not filtered.
NASA Technical Reports Server (NTRS)
1978-01-01
Telemetry is the process whereby physiological or other data is acquired by instruments, translated into radio signals and j sent to a receiving station where the signals are decoded and recorded. Extensively used in I space operations, it is finding new Earth applications, among them transmission of medical data between emergency vehicles and hospitals. For example, transmission of an electrocardiogram from an ambulance to a hospital enables a physician to read the telemetered EKG and advise ambulance attendants on emergency procedures. Central Medical Emergency Dispatch (CMED) operates as a regional emergency medical communications center for Cleveland, Ohio and Cuyahoga County. The CMED system includes radio and telephone communications from hospital-to-hospital and from ambulance-to-hospital, but for improved emergency life support CMED sought to add a county-wide telemetry capability. The problem was that there were only eight radio frequencies available for telemetry and there were more than 30 potential users in Cleveland alone. NASA's Lewis Research Center volunteered its expert assistance. The Center's engineers studied the systems of other telemetry using cities, surveyed area hospitals to assure compatibility of telemetry equipment, and advised what types of equipment would be needed in emergency vehicles and at the various hospitals. The Lewis plan suggested that CMED be designated the central coordinating agency for the Cuyahoga County system, monitoring all telemetry frequencies and, when requested, assigning one not in use or one to be used at a sufficient distance that it would create no interference problem.
NASA Technical Reports Server (NTRS)
1980-01-01
Lewis Research Center helped design the complex EMS Communication System, originating from space operated telemetry, including the telemetry link between ambulances and hospitals for advanced life support services. In emergency medical use telemetry links ambulances and hospitals for advanced life support services and allows transmission of physiological data -- an electrocardiogram from an ambulance to a hospital emergency room where a physician reads the telemetered message and prescribes emergency procedures to ambulance attendants.
Development of BION(TM) Technology for Functional Electrical Stimulation: Bidirectional Telemetry
2001-10-25
paralyzed limb , it is necessary to incorporate sensors and back telemetry to provide voluntary control and sensory feedback signals. We describe...requirements. Keywords - neural prostheses, electrical stimulation, implants, telemetry, sensors I. INTRODUCTION BIONs ( BIOnic Neurons) are modular...ents of a paralyzed limb will require a sophisticated control system that must be driven by two types of data from the patient: 1) command signals
A media player causes clinically significant telemetry interference with implantable loop recorders.
Thaker, Jay P; Patel, Mehul B; Shah, Ashok J; Liepa, Valdis V; Jongnarangsin, Krit; Thakur, Ranjan K
2009-03-01
The implantable loop recorder is a useful diagnostic tool for intermittent cardiovascular symptoms because it can automatically record arrhythmias as well as a patient-triggered ECG. Media players have been shown to cause telemetry interference with pacemakers. Telemetry interference may be important in patients with implantable loop recorders because capturing a patient-triggered ECG requires a telemetry link between a hand-held activator and the implanted device. The purpose of this study was to determine if a media player causes interference with implantable loop recorders. Fourteen patients with implantable loop recorders underwent evaluation for interference with a 15 GB third generation iPod (Apple, Inc.) media player. All patients had the Reveal Plus (Medtronic, Inc.) implantable loop recorder. We tested for telemetry interference on the programmer by first establishing a telemetry link with the loop recorder and then, the media player was placed next to it, first turned off and then, on. We evaluated for telemetry interference between the activator and the implanted device by placing the activator over the device (normal use) and the media player next to it, first turned off and then, on. We made 5 attempts to capture a patient-triggered ECG by depressing the activator switch 5 times while the media player was off or on. Telemetry interference on the programmer screen, consisting of either high frequency spikes or blanking of the ECG channel was seen in all patients. Telemetry interference with the activator resulted in failure to capture an event in 7 patients. In one of these patients, a green indicator light on the activator suggested that a patient-triggered event was captured, but loop recorder interrogation did not show a captured event. In the remaining 7 patients, an event was captured and appropriately recognized by the device at least 1 out of 5 times. A media player playing in close proximity to an implanted loop recorder may interfere with capture of a patient-triggered event. Patients should be advised to keep media players away from their implanted loop recorder.
Test Telemetry And Command System (TTACS)
NASA Technical Reports Server (NTRS)
Fogel, Alvin J.
1994-01-01
The Jet Propulsion Laboratory has developed a multimission Test Telemetry and Command System (TTACS) which provides a multimission telemetry and command data system in a spacecraft test environment. TTACS reuses, in the spacecraft test environment, components of the same data system used for flight operations; no new software is developed for the spacecraft test environment. Additionally, the TTACS is transportable to any spacecraft test site, including the launch site. The TTACS is currently operational in the Galileo spacecraft testbed; it is also being provided to support the Cassini and Mars Surveyor Program projects. Minimal personnel data system training is required in the transition from pre-launch spacecraft test to post-launch flight operations since test personnel are already familiar with the data system's operation. Additionally, data system components, e.g. data display, can be reused to support spacecraft software development; and the same data system components will again be reused during the spacecraft integration and system test phases. TTACS usage also results in early availability of spacecraft data to data system development and, as a result, early data system development feedback to spacecraft system developers. The TTACS consists of a multimission spacecraft support equipment interface and components of the multimission telemetry and command software adapted for a specific project. The TTACS interfaces to the spacecraft, e.g., Command Data System (CDS), support equipment. The TTACS telemetry interface to the CDS support equipment performs serial (RS-422)-to-ethernet conversion at rates between 1 bps and 1 mbps, telemetry data blocking and header generation, guaranteed data transmission to the telemetry data system, and graphical downlink routing summary and control. The TTACS command interface to the CDS support equipment is nominally a command file transferred in non-real-time via ethernet. The CDS support equipment is responsible for metering the commands to the CDS; additionally for Galileo, TTACS includes a real-time-interface to the CDS support equipment. The TTACS provides the basic functionality of the multimission telemetry and command data system used during flight operations. TTACS telemetry capabilities include frame synchronization, Reed-Solomon decoding, packet extraction and channelization, and data storage/query. Multimission data display capabilities are also available. TTACS command capabilities include command generation verification, and storage.
[Occupational nursing specialization: proposed change of paradigm].
Mauro, M Y
1998-01-01
The course of Labour Nursing aimed at preparing nurses for companies security and workers health. It started in 1974 as a result of the efforts of DESP/EEAN/UFRJ and ABEn close to the Ministry of Labour in Rio de Janeiro and based on the Resolution 112/59--OMS/OIT. Later, this course was spread out to other Universities and Brazil's regions and 13 courses have been provided until 1985. In the beginning, the courses follwed the orientation and control of FUNDACENTRO, until 1996 and were directed to the industry. From this time on, these courses register was sent to CORENs and accomplished independently at Nursing Schools, based on Resolution 12/86--MEC, Rec. 161/93--OIT. Instructions from the Ministry of Labour and Ministry of Health. At the EEAN, up to 1995, 11 Specialisation Courses have been accomplished, based on ANENT orientations and fundamental by the subjects: Scientific Investigation Methodology, Methodology of Nursing Teaching and Education for Health; Worker's Health Politics; Labour Organisational and Social Sciences; Environment Sanitation; Work Safety and Hygiene and Human Ecology; Ergonomy; Labour Process; Occupational Risks; Labour Accidents and Illnesses; Labour Legislation; Labour Nursing; Technical Visits and Practice in Workers Health Services at Companies Programmes and Public Health. The course enables nurses of essential, educative, managing and investigative activities and their formation culminates with a dissertation that has as a study object, emerging problems of nursing practice for workers. This programme has been studied by the author herself aiming at a better adjustment for these professionals insertion into the work market.
Outside the Continental United States International Travel and Contagion Impact Quick Look Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corley, Courtney D.; Lancaster, Mary J.; Brigantic, Robert T.
2012-11-09
ABSTRACT This paper describes a tool that will allow public health analysts to estimate infectious disease risk at the country level as a function of different international transportation modes. The prototype focuses on a cholera epidemic originating within Latin America or the Caribbean, but it can be expanded to consider other pathogens as well. This effort leverages previous work in collaboration with the Centers for Disease Control and Prevention to develop the International Travel to Community Impact (IT-CI) model, which analyzes and assesses potential international disease outbreaks then estimates the associated impacts to U.S. communities and the nation as amore » whole and orient it for use Outside the Continental United States (OCONUS). For brevity, we refer to this refined model as OIT-CI. First, we developed an operationalized meta-population spatial cholera model for Latin America and the Caribbean at the secondary administrative-level boundary. Secondly, we developed a robust function of human airline critical to approximating mixing patterns in the meta- population model. In the prototype version currently presented here, OIT-CI models a cholera epidemic originating in a Latin American or Caribbean country and spreading via airline transportation routes. Disease spread is modeled at the country level using a patch model with a connectivity function based on demographic, geospatial, and human transportation data. We have also identified data to estimate the water and health-related infrastructure capabilities of each country to include this potential impact on disease transmission.« less
Space shuttle data handling and communications considerations.
NASA Technical Reports Server (NTRS)
Stoker, C. J.; Minor, R. G.
1971-01-01
Operational and development flight instrumentation, data handling subsystems and communication requirements of the space shuttle orbiter are discussed. Emphasis is made on data gathering methods, crew display data, computer processing, recording, and telemetry by means of a digital data bus. Also considered are overall communication conceptual system aspects and design features allowing a proper specification of telemetry encoders and instrumentation recorders. An adaptive bit rate concept is proposed to handle the telemetry bit rates which vary with the amount of operational and experimental data to be transmitted. A split-phase encoding technique is proposed for telemetry to cope with the excessive bit jitter and low bit transition density which may affect television performance.
NASA Technical Reports Server (NTRS)
Layland, J. W.
1986-01-01
Acquiring telemetry data from the International Cometary Explorer (ICE) at its encounter with the comet Giacobini-Zinner on September 11, 1985 proved to be among the more difficult challenges the DSN has met in recent years. The ICE spacecraft began its life as an Earth orbiting monitor of the Solar Wind. At the comet, ICE was nearly 50 times as distant as in its initial role, with its signal strength diminished nearly 2500 times. Collecting enough of that weak signal to provide meaningful scientific data about the comet required unique new telemetry capabilities and special handling by the DSN. This article describes the development and validation of the DSN telemetry capability for ICE from its early planning stages through the successful comet encounter.
NASA Technical Reports Server (NTRS)
Scaffidi, C. A.; Stocklin, F. J.; Feldman, M. B.
1971-01-01
An L-band telemetry system designed to provide the capability of near-real-time processing of calibration data is described. The system also provides the capability of performing computerized spacecraft simulations, with the aircraft as a data source, and evaluating the network response. The salient characteristics of a telemetry analysis and simulation program (TASP) are discussed, together with the results of TASP testing. The results of the L-band system testing have successfully demonstrated the capability of near-real-time processing of telemetry test data, the control of the ground-received signal to within + or - 0.5 db, and the computer generation of test signals.
Wireless Sensor Network for Electric Transmission Line Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alphenaar, Bruce
Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and costmore » effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications. On such a platform, it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver real-time information to federal agencies and others tasked with grid reliability (Tasks 6,8).« less
Mobile Telemetry Van Remote Control Upgrade
2012-05-17
Advantages of Remote Control System Upgrade • Summary Overview • Remote control of Telemetry Mobile Ground Support ( TMGS ) Van proposed to allow...NWC) personnel provided valuable data for full-function remote control of telemetry tracking vans Background • TMGS Vans support Flight Test...control capability from main TM site at Building 5790 currently allows support via TMGS Van at nearby C- 15 Site, Plant 42 in Palmdale, and as far
A Model for Real-Time Data Reputation Via Cyber Telemetry
2016-06-01
TIME DATA REPUTATION VIA CYBER TELEMETRY by Beau M. Houser June 2016 Thesis Advisor: Dorothy E. Denning Co-Advisor: Phyllis Schneck...information is estimated to average 1 hour per response, including the time for reviewing instruction, searching existing data sources, gathering and...Master’s Thesis 4. TITLE AND SUBTITLE A MODEL FOR REAL- TIME DATA REPUTATION VIA CYBER TELEMETRY 5. FUNDING NUMBERS 6. AUTHOR(S) Beau M
An Advanced Commanding and Telemetry System
NASA Astrophysics Data System (ADS)
Hill, Maxwell G. G.
The Loral Instrumentation System 500 configured as an Advanced Commanding and Telemetry System (ACTS) supports the acquisition of multiple telemetry downlink streams, and simultaneously supports multiple uplink command streams for today's satellite vehicles. By using industry and federal standards, the system is able to support, without relying on a host computer, a true distributed dataflow architecture that is complemented by state-of-the-art RISC-based workstations and file servers.
Review of research methodologies for tigers: telemetry.
Miller, Clayton S; Hebblewhite, Mark; Goodrich, John M; Miquelle, Dale G
2010-12-01
Over the past half century, wildlife research has relied on technological advances to gain additional insight into the secretive lives of animals. This revolution started in the 1960s with the development of radio telemetry and continues today with the use of Global Positioning System (GPS)-based research techniques. In the present paper we review the history of radio telemetry from its origins with grizzly bears in Yellowstone to its early applications in tiger research and conservation in Asia. We address the different types of data that are available using radio telemetry as opposed to using other research techniques, such as behavioral observations, camera trapping, DNA analysis and scat analysis. In the late 1990s, the rapid development of GPS collar technology revolutionized wildlife research. This new technology has enabled researchers to dramatically improve their ability to gather data on animal movements and ecology. Despite the ecological and conservation benefits of radio telemetry, there have been few telemetry studies of tigers in the wild, and most have been on the Bengal or Amur subspecies. We close with an assessment of the current tiger conservation efforts using GPS technology and discuss how this new information can help to preserve tigers for future generations. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.
Non-invasive biosensor and wilreless interrogating system for hypoglycemia
NASA Astrophysics Data System (ADS)
Varadan, Vijay K.; Whitchurch, Ashwin K.; Saukesi, K.
2002-11-01
Hypoglycemia - abnormal decrease in blood sugar - is a major obstacle in the management of diabetes and prevention of long-term complications, and it may impose serious effects on the brain, including impairment of memory and other cognitive functions. This paper presents the development of a non-invasive sensor with miniaturized telemetry device in a wrist-watch for monitoring glucose concentration in blood. The sensor concept is based on optical chiralit of glucose level in the interstitial fluid. The wrist watch consists of a laser power source of the wavelength compatible with the glucose. A nanofilm with specific chirality is placed at the bottom of the watch. The light then passes through the film and illuminates a small area on the skin.It has been documented that there is certain concentration of sugar level is taken by the intertitial fluid from the blood stream and deposit a portion of it at the dead skin. The wrist-watch when in contact with the outer skin of the human will thus monitor the glucose concentration. A wireless monitoring system in the watch then downloads the data from the watch to a Palm or laptop computer.
Distributing Data to Hand-Held Devices in a Wireless Network
NASA Technical Reports Server (NTRS)
Hodges, Mark; Simmons, Layne
2008-01-01
ADROIT is a developmental computer program for real-time distribution of complex data streams for display on Web-enabled, portable terminals held by members of an operational team of a spacecraft-command-and-control center who may be located away from the center. Examples of such terminals include personal data assistants, laptop computers, and cellular telephones. ADROIT would make it unnecessary to equip each terminal with platform- specific software for access to the data streams or with software that implements the information-sharing protocol used to deliver telemetry data to clients in the center. ADROIT is a combination of middleware plus software specific to the center. (Middleware enables one application program to communicate with another by performing such functions as conversion, translation, consolidation, and/or integration.) ADROIT translates a data stream (voice, video, or alphanumerical data) from the center into Extensible Markup Language, effectuates a subscription process to determine who gets what data when, and presents the data to each user in real time. Thus, ADROIT is expected to enable distribution of operations and to reduce the cost of operations by reducing the number of persons required to be in the center.
Microsensors to monitor missile storage and maintenance needs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mee, D.K.; Thundat, T.G.; Oden, P.I.
1997-10-30
Accurate assessments of reliability and condition based maintenance can only be implemented where a good understanding of ammunition stockpile condition exists. Use of miniaturized intelligent sensors provides an inexpensive means of nondestructively gaining insight into stockpile condition while keeping costs low. In the past, evaluation of ammunition lifetimes has utilized humidity, temperature, pressure, shock, and corrosion. New technologies provide the possibility of obtaining these environmental parameters, as well as a number of other indicators of propellant degradation, including NOx by utilizing a microsensor with capability for remote wireless monitoring. Micro-electro-mechanical systems (MEMS) like microcantilevers promise to revolutionize the field ofmore » sensor design. In the automobile industry, micromachined acceleration sensors are now used for triggering airbags and pressure sensors adjust the air-fuel intake ratio in the engine. By applying coatings to the sensor`s surface the behavior of the microdevice can be measurably altered to respond to chemical species as demonstrated by ORNL using microcantilevers to detect mercury vapor and humidity. Ultimately, single-chip detectors with electronics and telemetry could be developed with conceivably hundreds of individual microsensors on each chip to simultaneously monitor identify, and quantify many important chemical species for ammunition as well as measure environmental parameters.« less
Development and Flight Testing of an Adaptable Vehicle Health-Monitoring Architecture
NASA Technical Reports Server (NTRS)
Woodard, Stanley E.; Coffey, Neil C.; Gonzalez, Guillermo A.; Woodman, Keith L.; Weathered, Brenton W.; Rollins, Courtney H.; Taylor, B. Douglas; Brett, Rube R.
2003-01-01
Development and testing of an adaptable wireless health-monitoring architecture for a vehicle fleet is presented. It has three operational levels: one or more remote data acquisition units located throughout the vehicle; a command and control unit located within the vehicle; and a terminal collection unit to collect analysis results from all vehicles. Each level is capable of performing autonomous analysis with a trained adaptable expert system. The remote data acquisition unit has an eight channel programmable digital interface that allows the user discretion for choosing type of sensors; number of sensors, sensor sampling rate, and sampling duration for each sensor. The architecture provides framework for a tributary analysis. All measurements at the lowest operational level are reduced to provide analysis results necessary to gauge changes from established baselines. These are then collected at the next level to identify any global trends or common features from the prior level. This process is repeated until the results are reduced at the highest operational level. In the framework, only analysis results are forwarded to the next level to reduce telemetry congestion. The system's remote data acquisition hardware and non-analysis software have been flight tested on the NASA Langley B757's main landing gear.
Didactic satellite based on Android platform for space operation demonstration and development
NASA Astrophysics Data System (ADS)
Ben Bahri, Omar; Besbes, Kamel
2018-03-01
Space technology plays a pivotal role in society development. It offers new methods for telemetry, monitoring and control. However, this sector requires training, research and skills development but the lack of instruments, materials and budgets affects the ambiguity to understand satellite technology. The objective of this paper is to describe a demonstration prototype of a smart phone device for space operations study. Therefore, the first task was carried out to give a demonstration for spatial imagery and attitude determination missions through a wireless communication. The smart phone's Bluetooth was used to achieve this goal inclusive of a new method to enable real time transmission. In addition, an algorithm around a quaternion based Kalman filter was included in order to detect the reliability of the prototype's orientation. The second task was carried out to provide a demonstration for the attitude control mission using the smart phone's orientation sensor, including a new method for an autonomous guided mode. As a result, the acquisition platform showed real time measurement with good accuracy for orientation detection and image transmission. In addition, the prototype kept the balance during the demonstration based on the attitude control method.
Acoustic Sensing and Ultrasonic Drug Delivery in Multimodal Theranostic Capsule Endoscopy
Stewart, Fraser R.; Qiu, Yongqiang; Newton, Ian P.; Cox, Benjamin F.; Al-Rawhani, Mohammed A.; Beeley, James; Liu, Yangminghao; Huang, Zhihong; Cumming, David R. S.; Näthke, Inke
2017-01-01
Video capsule endoscopy (VCE) is now a clinically accepted diagnostic modality in which miniaturized technology, an on-board power supply and wireless telemetry stand as technological foundations for other capsule endoscopy (CE) devices. However, VCE does not provide therapeutic functionality, and research towards therapeutic CE (TCE) has been limited. In this paper, a route towards viable TCE is proposed, based on multiple CE devices including important acoustic sensing and drug delivery components. In this approach, an initial multimodal diagnostic device with high-frequency quantitative microultrasound that complements video imaging allows surface and subsurface visualization and computer-assisted diagnosis. Using focused ultrasound (US) to mark sites of pathology with exogenous fluorescent agents permits follow-up with another device to provide therapy. This is based on an US-mediated targeted drug delivery system with fluorescence imaging guidance. An additional device may then be utilized for treatment verification and monitoring, exploiting the minimally invasive nature of CE. While such a theranostic patient pathway for gastrointestinal treatment is presently incomplete, the description in this paper of previous research and work under way to realize further components for the proposed pathway suggests it is feasible and provides a framework around which to structure further work. PMID:28671642
An affordable modular vehicle radar for landmine and IED detection
NASA Astrophysics Data System (ADS)
Daniels, David; Curtis, Paul; Dittmer, Jon; Hunt, Nigel; Graham, Blair; Allan, Robert
2009-05-01
This paper describes a vehicle mounted 8-channel radar system suitable for buried landmine and IED detection. The system is designed to find Anti Tank (AT) landmines and buried Improvised Explosive Devices (IEDs). The radar uses field-proven ground penetrating radar sub-system modules and is scalable to 16, 32 or 64 channels, for covering greater swathe widths and for providing higher cross track resolution. This offers the capability of detecting smaller targets down to a minimum dimension of 100mm. The current rate of advance of the technology demonstrator is 10 kph; this can be increased to 20 kph where required. The data output is triggered via shaft encoder or via GPS and, for each forward increment; the data output is variable from a single byte per channel through to the 512 samples per channel. Trials using an autonomous vehicle, combined with a COFDM wireless link for data and telemetry back to a base station, have proven successful and the system architecture is described in this paper. The GPR array can be used as a standalone sensor or can be integrated with off-the-shelf software and a metal detection array.
Popescu, Viorel D; Valpine, Perry; Sweitzer, Rick A
2014-04-01
Wildlife data gathered by different monitoring techniques are often combined to estimate animal density. However, methods to check whether different types of data provide consistent information (i.e., can information from one data type be used to predict responses in the other?) before combining them are lacking. We used generalized linear models and generalized linear mixed-effects models to relate camera trap probabilities for marked animals to independent space use from telemetry relocations using 2 years of data for fishers (Pekania pennanti) as a case study. We evaluated (1) camera trap efficacy by estimating how camera detection probabilities are related to nearby telemetry relocations and (2) whether home range utilization density estimated from telemetry data adequately predicts camera detection probabilities, which would indicate consistency of the two data types. The number of telemetry relocations within 250 and 500 m from camera traps predicted detection probability well. For the same number of relocations, females were more likely to be detected during the first year. During the second year, all fishers were more likely to be detected during the fall/winter season. Models predicting camera detection probability and photo counts solely from telemetry utilization density had the best or nearly best Akaike Information Criterion (AIC), suggesting that telemetry and camera traps provide consistent information on space use. Given the same utilization density, males were more likely to be photo-captured due to larger home ranges and higher movement rates. Although methods that combine data types (spatially explicit capture-recapture) make simple assumptions about home range shapes, it is reasonable to conclude that in our case, camera trap data do reflect space use in a manner consistent with telemetry data. However, differences between the 2 years of data suggest that camera efficacy is not fully consistent across ecological conditions and make the case for integrating other sources of space-use data.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-01-01
This conference presents papers in the fields of airborne telemetry, measurement technology, video instrumentation and monitoring, tracking and receiving systems, and real-time processing in telemetry. Topics presented include packet telemetry ground station simulation, a predictable performance wideband noise generator, an improved drone tracking control system transponder, the application of neural networks to drone control, and an integrated real-time turbine engine flight test system.
Implantable telemetry for small animals
NASA Astrophysics Data System (ADS)
1982-03-01
A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.
Implantable telemetry for small animals
NASA Technical Reports Server (NTRS)
1982-01-01
A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.
The advanced receiver 2: Telemetry test results in CTA 21
NASA Technical Reports Server (NTRS)
Hinedi, S.; Bevan, R.; Marina, M.
1991-01-01
Telemetry tests with the Advanced Receiver II (ARX II) in Compatibility Test Area 21 are described. The ARX II was operated in parallel with a Block-III Receiver/baseband processor assembly combination (BLK-III/BPA) and a Block III Receiver/subcarrier demodulation assembly/symbol synchronization assembly combination (BLK-III/SDA/SSA). The telemetry simulator assembly provided the test signal for all three configurations, and the symbol signal to noise ratio as well as the symbol error rates were measured and compared. Furthermore, bit error rates were also measured by the system performance test computer for all three systems. Results indicate that the ARX-II telemetry performance is comparable and sometimes superior to the BLK-III/BPA and BLK-III/SDA/SSA combinations.
VLSI technology for smaller, cheaper, faster return link systems
NASA Technical Reports Server (NTRS)
Nanzetta, Kathy; Ghuman, Parminder; Bennett, Toby; Solomon, Jeff; Dowling, Jason; Welling, John
1994-01-01
Very Large Scale Integration (VLSI) Application-specific Integrated Circuit (ASIC) technology has enabled substantially smaller, cheaper, and more capable telemetry data systems. However, the rapid growth in available ASIC fabrication densities has far outpaced the application of this technology to telemetry systems. Available densities have grown by well over an order magnitude since NASA's Goddard Space Flight Center (GSFC) first began developing ASIC's for ground telemetry systems in 1985. To take advantage of these higher integration levels, a new generation of ASIC's for return link telemetry processing is under development. These new submicron devices are designed to further reduce the cost and size of NASA return link processing systems while improving performance. This paper describes these highly integrated processing components.
Miniature infrared data acquisition and telemetry system
NASA Technical Reports Server (NTRS)
Stokes, J. H.; Ward, S. M.
1985-01-01
The Miniature Infrared Data Acquisition and Telemetry (MIRDAT) Phase 1 study was performed to determine the technical and commercial feasibility of producing a miniaturized electro-optical telemetry system. This system acquires and transmits experimental data from aircraft scale models for realtime monitoring in wind tunnels. During the Phase 1 study, miniature prototype MIRDAT telemetry devices were constructed, successfully tested in the laboratory and delivered to the user for wind tunnel testing. A search was conducted for commercially available components and advanced hybrid techniques to further miniaturize the system during Phase 2 development. A design specification was generated from laboratory testing, user requirements and discussions with component manufacturers. Finally, a preliminary design of the proposed MIRDAT system was documented for Phase 2 development.
1990-05-01
U Aberden Proving Ground , SID 21, 5066 Em OFFICIAL BUSINESS I_______ BUSINESS REPLY MAIL____ FIRST CLASS PERMIT No 0001, APG, MD POSTAGE WILL BE P040...JUN1319SUUWI &B •AFOV FOR PUKJC RE,,AS, DIS7RIBUTION UNLIMiED. U.S. ARMY LABORATORY COMMAND BALLISTIC RESEARCH LABORATORY ABERDEEN PROVING GROUND , MARYLAND 90 o...It. SPOSO MIIOWOiM -C WOE? - Ballistic Research Laboratory ATTN: SLCBR-DD-T Aberdeen Proving Ground , MD 21005-5066 11. SUPPLEMENTARY NOTES *The Johns
Involuntary outpatient treatment (iot) for severe mental patients: current situation in Spain.
Cañete-Nicolás, Carlos; Hernández-Viadel, Miguel; Bellido-Rodríguez, Carmen; Lera-Calatayud, Guillem; Asensio-Pascual, Pedro; Pérez-Prieto, Juan F; Calabuig-Crespo, Roman; Leal-Cercós, Carmen
2012-01-01
Involuntary Outpatient Treatment (IOT) expects to improve treatment compliance and, therefore, prevent the impairment of patients with severe mental illness, as well as the risk for them and others. Besides IOT introduction defenders and opponent's states, scientific literature offers contradictory results. Legislative changes have been taken in the vast majority of our neighbouring countries in order to regulate IOT application. There is no legal regulation in Spain; however, OIT application is possible in certain Spanish cities. This article reviews IOT in Spain and surrounding countries.
U.S. Navy Regional Climatic Study of the Mozambique Channel and Adjacent Waters
1989-07-01
vector 5iur if....7M. nalc2to rl movements f troica cyclone wace ers* kot w oit o t his rose ore hosed on 277 tg ele hour4 I Il/r, \\movements In co p n50... method best represents the climate. At this point, however, it is possible only to bring the issue to the attention of the data users. Even without the...temperatures are recorded with a fairly high frequency in marine observations. The principle methods for sampling are with ship water-intake thermometers and
1984-04-23
Olsen SI• 23 April-198A ! Lf), i’-iApproved for public release; distribution unli~mited. S •~~i 4 0 9 .- 020 . Approved for public release... Houk , MC, USN Chief Scientific Advisor Commanding Officer 23 April 1984 NAVAL, AEROSPACE MEDICAL RESEARCH LABORATORY ,NVAL AIR STATION PENSACOLA, FLORIDA...Distrl ,oit i nti/ Avaiiab! itv Codes Avaw I !/or ii L- - - • - -•. . .. . T . . . . .. . . . v ’ - • q T ’ : • : ,-t INTRODUCTION Radio
Lessons Learned During Implementation and Early Operations of the DS1 Beacon Monitor Experiment
NASA Technical Reports Server (NTRS)
Sherwood, Rob; Wyatt, Jay; Hotz, Henry; Schlutsmeyer, Alan; Sue, Miles
1998-01-01
A new approach to mission operations will be flight validated on NASA's New Millennium Program Deep Space One (DS1) mission which launched in October 1998. The Beacon Monitor Operations Technology is aimed at decreasing the total volume of downlinked engineering telemetry by reducing the frequency of downlink and the volume of data received per pass. Cost savings are achieved by reducing the amount of routine telemetry processing and analysis performed by ground staff. The technology is required for upcoming NASA missions to Pluto, Europa, and possibly some other missions. With beacon monitoring, the spacecraft will assess its own health and will transmit one of four beacon messages each representing a unique frequency tone to inform the ground how urgent it is to track the spacecraft for telemetry. If all conditions are nominal, the tone provides periodic assurance to ground personnel that the mission is proceeding as planned without having to receive and analyze downlinked telemetry. If there is a problem, the tone will indicate that tracking is required and the resulting telemetry will contain a concise summary of what has occurred since the last telemetry pass. The primary components of the technology are a tone monitoring technology, AI-based software for onboard engineering data summarization, and a ground response system. In addition, there is a ground visualization system for telemetry summaries. This paper includes a description of the Beacon monitor concept, the trade-offs with adapting that concept as a technology experiment, the current state of the resulting implementation on DS1, and our lessons learned during the initial checkout phase of the mission. Applicability to future missions is also included.
XTCE (XML Telemetric and Command Exchange) Standard Making It Work at NASA. Can It Work For You?
NASA Technical Reports Server (NTRS)
Munoz-Fernandez, Michela; Smith, Danford S.; Rice, James K.; Jones, Ronald A.
2017-01-01
The XML Telemetric and Command Exchange (XTCE) standard is intended as a way to describe telemetry and command databases to be exchanged across centers and space agencies. XTCE usage has the potential to lead to consolidation of the Mission Operations Center (MOC) Monitor and Control displays for mission cross-support, reducing equipment and configuration costs, as well as a decrease in the turnaround time for telemetry and command modifications during all the mission phases. The adoption of XTCE will reduce software maintenance costs by reducing the variation between our existing mission dictionaries. The main objective of this poster is to show how powerful XTCE is in terms of interoperability across centers and missions. We will provide results for a use case where two centers can use their local tools to process and display the same mission telemetry in their MOC independently of one another. In our use case we have first quantified the ability for XTCE to capture the telemetry definitions of the mission by use of our suite of support tools (Conversion, Validation, and Compliance measurement). The next step was to show processing and monitoring of the same telemetry in two mission centers. Once the database was converted to XTCE using our tool, the XTCE file became our primary database and was shared among the various tool chains through their XTCE importers and ultimately configured to ingest the telemetry stream and display or capture the telemetered information in similar ways.Summary results include the ability to take a real mission database and real mission telemetry and display them on various tools from two centers, as well as using commercially free COTS.
The U.S. Animal Telemetry Network: A Plan for Implementation
NASA Astrophysics Data System (ADS)
Weise, M. J.; Simmons, S. E.
2016-02-01
The U.S. is a global leader in animal telemetry, with tremendous animal telemetry infrastructure and considerable technical expertise in telemetry operations. However, these research assets are often owned and operated independently by multiple agencies and institutions with limited to no connectivity. This prevents the scientific community from efficiently coordinating data and thereby best serving societal needs. In this talk we will describe how the U.S. Animal Telemetry Network (ATN), under the auspices of the U.S. Integrated Ocean Observing System (IOOS), will provide a mechanism to facilitate and empower an alliance among federal, industry, academic, state, local, tribal, and non-federal organizations. Animal telemetry technology is now considered mature and operational, and these observing data and products are ready to be integrated into the U.S. IOOS. The ATN data management approach involves receiving, handling, and distributing diverse data types from archival, satellite, and acoustic tag platforms that originate from a variety of individual researchers and large programs using consistent metadata standards and best practices. The core of the ATN data management system will be a quasi-centralized national ATN Data Assembly Center that will receive and distribute data and data products to U.S. IOOS RAs and other partner organizations. The integration of biological resources into ocean observation will address U.S. IOOS needs regarding societal benefits by, for example, aiming to improve predictions of climate change, to more effectively protect and restore healthy coastal ecosystems, and to enable the sustained use of ocean and coastal resources. We will describe the plan for how the ATN will maximize the benefit of existing investments by providing a mechanism for sustained operations and consistent delivery of animal telemetry data across the U.S. and in conjunction with international ocean observing systems.
Estimating animal resource selection from telemetry data using point process models
Johnson, Devin S.; Hooten, Mevin B.; Kuhn, Carey E.
2013-01-01
To demonstrate the analysis of telemetry data with the point process approach, we analysed a data set of telemetry locations from northern fur seals (Callorhinus ursinus) in the Pribilof Islands, Alaska. Both a space–time and an aggregated space-only model were fitted. At the individual level, the space–time analysis showed little selection relative to the habitat covariates. However, at the study area level, the space-only model showed strong selection relative to the covariates.
The usefulness of GPS telemetry to study wolf circadian and social activity
Merrill, Samuel B.; Mech, L. David
2003-01-01
This study describes circadian and social movement patterns of 9 wolves and illustrates capabilities and limitations of Global Positioning System (GPS) telemetry for analysis of animal activity patterns. Global Positioning System telemetry was useful in determining when pack members were traveling together or apart and how long a breeding female wolf spent near her pups (e.g., 10-month-old pups were left unattended by their mother for as long as 17 days).
Leveraging constraints and biotelemetry data to pinpoint repetitively used spatial features
Brost, Brian M.; Hooten, Mevin B.; Small, Robert J.
2016-01-01
Satellite telemetry devices collect valuable information concerning the sites visited by animals, including the location of central places like dens, nests, rookeries, or haul‐outs. Existing methods for estimating the location of central places from telemetry data require user‐specified thresholds and ignore common nuances like measurement error. We present a fully model‐based approach for locating central places from telemetry data that accounts for multiple sources of uncertainty and uses all of the available locational data. Our general framework consists of an observation model to account for large telemetry measurement error and animal movement, and a highly flexible mixture model specified using a Dirichlet process to identify the location of central places. We also quantify temporal patterns in central place use by incorporating ancillary behavioral data into the model; however, our framework is also suitable when no such behavioral data exist. We apply the model to a simulated data set as proof of concept. We then illustrate our framework by analyzing an Argos satellite telemetry data set on harbor seals (Phoca vitulina) in the Gulf of Alaska, a species that exhibits fidelity to terrestrial haul‐out sites.
Precise timing correlation in telemetry recording and processing systems
NASA Technical Reports Server (NTRS)
Pickett, R. B.; Matthews, F. L.
1973-01-01
Independent PCM telemetry data signals received from missiles must be correlated to within + or - 100 microseconds for comparison with radar data. Tests have been conducted to determine RF antenna receiving system delays; delays associated with wideband analog tape recorders used in the recording, dubbing and repdocuing processes; and uncertainties associated with computer processed time tag data. Several methods used in the recording of timing are evaluated. Through the application of a special time tagging technique, the cumulative timing bias from all sources is determined and the bias removed from final data. Conclusions show that relative time differences in receiving, recording, playback and processing of two telemetry links can be accomplished with a + or - 4 microseconds accuracy. In addition, the absolute time tag error (with respect to UTC) can be reduced to less than 15 microseconds. This investigation is believed to be the first attempt to identify the individual error contributions within the telemetry system and to describe the methods of error reduction within the telemetry system and to describe the methods of error reduction and correction.
Satellite Relay Telemetry of Seismic Data in Earthquake Prediction and Control
NASA Technical Reports Server (NTRS)
Jackson, W. H.; Eaton, J. P.
1971-01-01
The Satellite Telemetry Earthquake Monitoring Program was started to evaluate the applicability of satellite relay telemetry in the collection of seismic data from a large number of dense seismograph clusters laid out along the major fault systems of western North America. Prototype clusters utilizing phone-line telemetry were then being installed by the National Center for Earthquake Research in 3 regions along the San Andreas fault in central California; and the experience of installing and operating the clusters and in reducing and analyzing the seismic data from them was to provide the raw materials for evaluation in the satellite relay telemetry project. The principal advantages of the satellite relay system over commercial telephone or microwave systems were: (1) it could be made less prone to massive failure during a major earthquake; (2) it could be extended readily into undeveloped regions; and (3) it could provide flexible, uniform communications over large sections of major global tectonic zones. Fundamental characteristics of a communications system to cope with the large volume of raw data collected by a short-period seismograph network are discussed.
Mens, Lucas H. M.
2007-01-01
During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to monitor the proper functioning of the implanted electronics and electrode contacts. Telemetry can also support the clinical management in young children and difficult cases where neural unresponsiveness is suspected. This article will review recent advances in the telemetry of the electrically evoked compound action potential that have made these measurements simple and routine procedures in most cases. The distribution of the electrical stimulus itself sampled by “electrical field imaging” reveals general patterns of current flow in the normal cochlea and gross abnormalities in individual patients; models have been developed to derive more subtle insights from an individual electrical field imaging. Finally, some thoughts are given to the extended application of telemetry, for example, in monitoring the neural responses or in combination with other treatments of the deaf ear. PMID:17709572
NASA Technical Reports Server (NTRS)
Stanboli, Alice
2013-01-01
Phxtelemproc is a C/C++ based telemetry processing program that processes SFDU telemetry packets from the Telemetry Data System (TDS). It generates Experiment Data Records (EDRs) for several instruments including surface stereo imager (SSI); robotic arm camera (RAC); robotic arm (RA); microscopy, electrochemistry, and conductivity analyzer (MECA); and the optical microscope (OM). It processes both uncompressed and compressed telemetry, and incorporates unique subroutines for the following compression algorithms: JPEG Arithmetic, JPEG Huffman, Rice, LUT3, RA, and SX4. This program was in the critical path for the daily command cycle of the Phoenix mission. The products generated by this program were part of the RA commanding process, as well as the SSI, RAC, OM, and MECA image and science analysis process. Its output products were used to advance science of the near polar regions of Mars, and were used to prove that water is found in abundance there. Phxtelemproc is part of the MIPL (Multi-mission Image Processing Laboratory) system. This software produced Level 1 products used to analyze images returned by in situ spacecraft. It ultimately assisted in operations, planning, commanding, science, and outreach.
Telemetry data via communications relay
NASA Astrophysics Data System (ADS)
Strock, O. J.; Witchey, Michael
This paper responds to a test range engineer's need to relay one or more channels of various types of telemetry data from a remotely-located receiving station to the central telemetry station at range headquarters for real-time processing and display. Several types of data are identified, and specific equipment and technology for multiplexing, transmission, and demultiplexing up to eight streams from a variety of sources is discussed. The widely-used T3 communications link, also known as DS-3, can relay data via satellite, microwave link, or other high-speed path at 44.736 megabits per second, of which about 95 percent can be actual telemetry data; other standard links operate at lower aggregate rates. Several links and rates are discussed, with emphasis in the high-rate T3 link.
Telemetry Applications Handbook
2006-05-01
Guidelines .......................................................... 3-2 3.4 References for Chapter 3...and Discriminators ............................................................. 4-45 4.8 Receiving/Recording System Parameter Selection Guidelines ...2-176 Figure 2-199. DSQ- 50 telemetry transmitter + BPF + LNA. ........................................... 2-177
Using Onboard Telemetry for MAVEN Orbit Determination
NASA Technical Reports Server (NTRS)
Lam, Try; Trawny, Nikolas; Lee, Clifford
2013-01-01
Determination of the spacecraft state has been traditional done using radiometric tracking data before and after the atmosphere drag pass. This paper describes our approach and results to include onboard telemetry measurements in addition to radiometric observables to refine the reconstructed trajectory estimate for the Mars Atmosphere and Volatile Evolution Mission (MAVEN). Uncertainties in the Mars atmosphere models, combined with non-continuous tracking degrade navigation accuracy, making MAVEN a key candidate for using onboard telemetry data to help complement its orbit determination process.
1999-01-01
fMr- ir ») 5<s © oo vo «o vo vo t- 3 -6 TABLE 3 - 3 . REFERENCE SIGNAL USAGE Reference Frequencies for Tape Speed and Flutter Compensation...maximum frequency response of tables 3 -1 and 3 -2, !K. M. Uglow, Noise and Bandwidth in FM/FM Radio Telemetry. IRE Transaction on Telemetry and...t4 u N s O i Q • I-H D-12 Bit Rate Clock Input ’ r if ir it if , IF RNRZ-L Data 1 2 3 15 - Stage Shift Register 13
Arning, Jürgen; Dringen, Ralf; Schmidt, Maike; Thiessen, Anette; Stolte, Stefan; Matzke, Marianne; Bottin-Weber, Ulrike; Caesar-Geertz, Birgit; Jastorff, Bernd; Ranke, Johannes
2008-04-18
To investigate the toxic mode of action of isothiazol-3-one biocides the four compounds N-methylisothiazol-3-one (MIT), 5-chloro-N-methylisothiazol-3-one (CIT), N-octylisothiazol-3-one (OIT) and 4,5-dichloro-N-octylisothiazol-3-one (DCOIT) were purified and tested as single chemical entities for their effects on the human hepatoblastoma cell line Hep G2 and on isolated and cellular glutathione reductase GR). The two chlorinated substances CIT and DCOIT significantly decreased the amount of total cellular glutathione (GSx) in a dose and time dependent manner. Concomitantly, an increase in the level of oxidised glutathione (GSSG) was observed. The resulting shift in the GSH/GSSG ratio entailing the breakdown of the cellular thiol reduction potential was accompanied by necrotic morphological changes like swelling of the plasma membrane and subsequent lysis of the cells. Additionally, CIT and DCOIT were found to inhibit cellular GR in the cells in a concentration dependent manner. The T-SAR-based (thinking in terms of structure-activity relationships) comparison of the chlorine-substituted structures CIT and DCOIT with their non-chlorinated and less active analogues MIT and OIT identified the chlorine substituents and the resulting reaction mechanisms to be the key structural mediators of the observed toxic effects. Furthermore, differences in the activity of both chlorinated substances could be explained using the T-SAR approach to link the lipophilicity and the intrinsic glutathione-reactivity of the compounds to the expected target site concentrations inside the cells.
Advanced Industrial Materials (AIM) program. Annual progress report. FY 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-04-01
The Advanced Industrial Materials (AIM) Program underwent a major transformation in Fiscal Year 1995 and these changes have continued to the present. When the Program was established in 1990 as the Advanced Industrial Concepts (AIC) Materials Program, the mission was to conduct applied research and development to bring materials and processing technologies from the knowledge derived from basic research to the maturity required for the end use sectors for commercialization. In 1995, the Office of Industrial Technologies (OIT) made radical changes in structure and procedures. All technology development was directed toward the seven `Vision Industries` that use about 80% ofmore » industrial energy and generated about 90% of industrial wastes. These are: aluminium; chemical; forest products; glass; metal casting; refineries; and steel. OIT is working with these industries, through appropriate organizations, to develop Visions of the desired condition of each industry some 20 or 25 years in the future and then to prepare Road Maps and Implementation Plans to enable them to reach their goals. The mission of AIM has, therefore, changed to `Support development and commercialization of new or improved materials to improve productivity, product quality, and energy efficiency in the major process industries.` Though AIM remains essentially a National Laboratory Program, it is necessary that each project have industrial partners, including suppliers to, and customers of, the seven industries. Now, well into FY 1996, the transition is nearly complete and the AIM Program remains healthy and productive, thanks to the superb investigators and Laboratory Program Managers. Separate abstracts have been indexed into the energy database for articles from this report.« less
NASA Technical Reports Server (NTRS)
Greene, E. P.
1976-01-01
The requirements for mission-operations data management will accelerate sharply when the Space Transportation System (i.e., Space Shuttle) becomes the primary vehicle for research from space. These demands can be satisfied most effectively by providing a higher-level source encoding function within the spaceborne vehicle. An Instrument Telemetry Packet (ITP) concept is described which represents an alternative to the conventional multiplexed telemetry frame approach for acquiring spaceborne instrument data. By providing excellent data-integrity protection at the source and a variable instrument bandwidth capability, this ITP concept represents a significant improvement over present data acquisition procedures. Realignments in the ground telemetry processing functions are described which are intended to take advantage of the ITP concept and to make the data management system more responsive to the scientific investigators.
Single frequency RF powered ECG telemetry system
NASA Technical Reports Server (NTRS)
Ko, W. H.; Hynecek, J.; Homa, J.
1979-01-01
It has been demonstrated that a radio frequency magnetic field can be used to power implanted electronic circuitry for short range telemetry to replace batteries. A substantial reduction in implanted volume can be achieved by using only one RF tank circuit for receiving the RF power and transmitting the telemetered information. A single channel telemetry system of this type, using time sharing techniques, was developed and employed to transmit the ECG signal from Rhesus monkeys in primate chairs. The signal from the implant is received during the period when the RF powering radiation is interrupted. The ECG signal is carried by 20-microsec pulse position modulated pulses, referred to the trailing edge of the RF powering pulse. Satisfactory results have been obtained with this single frequency system. The concept and the design presented may be useful for short-range long-term implant telemetry systems.
GTAG: architecture and design of miniature transmitter with position logging for radio telemetry
NASA Astrophysics Data System (ADS)
Řeřucha, Šimon; Bartonička, Tomáš; Jedlička, Petr
2011-10-01
The radio telemetry is a well-known technique used within zoological research to exploit the behaviour of animal species. A usage of GPS for a frequent and precise position recording gives interesting possibility for a further enhancement of this method. We present our proposal of an architecture and design concepts of telemetry transmitter with GPS module, called GTAG, that is suited for study of the Egyptian fruit bat (Rousettus aegyptiacus). The model group we study set particular constrains, especially the weight limit (9 g) and prevention of any power resources recharging technique. We discuss the aspect of physical realization and the energyconsumption issues. We have developed a reference implementation that has been already deployed during telemetry sessions and we evaluate the experience and compare the estimated performance of our device to a real data.
Validation of International Space Station Electrical Performance Model via On-orbit Telemetry
NASA Technical Reports Server (NTRS)
Jannette, Anthony G.; Hojnicki, Jeffrey S.; McKissock, David B.; Fincannon, James; Kerslake, Thomas W.; Rodriguez, Carlos D.
2002-01-01
The first U.S. power module on International Space Station (ISS) was activated in December 2000. Comprised of solar arrays, nickel-hydrogen (NiH2) batteries, and a direct current power management and distribution (PMAD) system, the electric power system (EPS) supplies power to housekeeping and user electrical loads. Modeling EPS performance is needed for several reasons, but primarily to assess near-term planned and off-nominal operations and because the EPS configuration changes over the life of the ISS. The System Power Analysis for Capability Evaluation (SPACE) computer code is used to assess the ISS EPS performance. This paper describes the process of validating the SPACE EPS model via ISS on-orbit telemetry. To accomplish this goal, telemetry was first used to correct assumptions and component models in SPACE. Then on-orbit data was directly input to SPACE to facilitate comparing model predictions to telemetry. It will be shown that SPACE accurately predicts on-orbit component and system performance. For example, battery state-of-charge was predicted to within 0.6 percentage points over a 0 to 100 percent scale and solar array current was predicted to within a root mean square (RMS) error of 5.1 Amps out of a typical maximum of 220 Amps. First, SPACE model predictions are compared to telemetry for the ISS EPS components: solar arrays, NiH2 batteries, and the PMAD system. Second, SPACE predictions for the overall performance of the ISS EPS are compared to telemetry and again demonstrate model accuracy.
FPGA for Power Control of MSL Avionics
NASA Technical Reports Server (NTRS)
Wang, Duo; Burke, Gary R.
2011-01-01
A PLGT FPGA (Field Programmable Gate Array) is included in the LCC (Load Control Card), GID (Guidance Interface & Drivers), TMC (Telemetry Multiplexer Card), and PFC (Pyro Firing Card) boards of the Mars Science Laboratory (MSL) spacecraft. (PLGT stands for PFC, LCC, GID, and TMC.) It provides the interface between the backside bus and the power drivers on these boards. The LCC drives power switches to switch power loads, and also relays. The GID drives the thrusters and latch valves, as well as having the star-tracker and Sun-sensor interface. The PFC drives pyros, and the TMC receives digital and analog telemetry. The FPGA is implemented both in Xilinx (Spartan 3- 400) and in Actel (RTSX72SU, ASX72S). The Xilinx Spartan 3 part is used for the breadboard, the Actel ASX part is used for the EM (Engineer Module), and the pin-compatible, radiation-hardened RTSX part is used for final EM and flight. The MSL spacecraft uses a FC (Flight Computer) to control power loads, relays, thrusters, latch valves, Sun-sensor, and star-tracker, and to read telemetry such as temperature. Commands are sent over a 1553 bus to the MREU (Multi-Mission System Architecture Platform Remote Engineering Unit). The MREU resends over a remote serial command bus c-bus to the LCC, GID TMC, and PFC. The MREU also sends out telemetry addresses via a remote serial telemetry address bus to the LCC, GID, TMC, and PFC, and the status is returned over the remote serial telemetry data bus.
A strategy for recovering continuous behavioral telemetry data from Pacific walruses
Fischbach, Anthony S.; Jay, Chadwick V.
2016-01-01
Tracking animal behavior and movement with telemetry sensors can offer substantial insights required for conservation. Yet, the value of data collected by animal-borne telemetry systems is limited by bandwidth constraints. To understand the response of Pacific walruses (Odobenus rosmarus divergens) to rapid changes in sea ice availability, we required continuous geospatial chronologies of foraging behavior. Satellite telemetry offered the only practical means to systematically collect such data; however, data transmission constraints of satellite data-collection systems limited the data volume that could be acquired. Although algorithms exist for reducing sensor data volumes for efficient transmission, none could meet our requirements. Consequently, we developed an algorithm for classifying hourly foraging behavior status aboard a tag with limited processing power. We found a 98% correspondence of our algorithm's classification with a test classification based on time–depth data recovered and characterized through multivariate analysis in a separate study. We then applied our algorithm within a telemetry system that relied on remotely deployed satellite tags. Data collected by these tags from Pacific walruses across their range during 2007–2015 demonstrated the consistency of foraging behavior collected by this strategy with data collected by data logging tags; and demonstrated the ability to collect geospatial behavioral chronologies with minimal missing data where recovery of data logging tags is precluded. Our strategy for developing a telemetry system may be applicable to any study requiring intelligent algorithms to continuously monitor behavior, and then compress those data into meaningful information that can be efficiently transmitted.
The Micro-Instrumentation Package: A Solution to Lightweight Ballooning
NASA Astrophysics Data System (ADS)
Juneau, Jill
This paper discusses the design and testing of an over the horizon (OTH) light weight telemetry and termination system that can be used for small ballooning payloads. Currently, the Columbia Scientific Balloon Facility (CSBF) provides telemetry for the science payload by integrating one of two types of support packages. The type of support package integrated depends on whether the flight will stay in range of line of sight (LOS) or will exceed LOS requiring the use of over the horizon (OTH) telemetry. The weights of these systems range from 100 pounds to 350 pounds depending upon the use of redundant systems, equipment for high data rates, and batteries and/or solar panels for power requirements. These weight values are not as significant for larger payloads but can be crippling for smaller payloads. In addition, these support package systems are fairly expensive, placing a high importance on recovery. A lightweight and inexpensive telemetry system could be beneficial for various reasons. First, it would allow scientists to fly lightweight payloads on large balloons reaching even higher altitudes. Second, scientists could fly lightweight payloads on less expensive balloons such as meteorological balloons. Depending on the payload, these flights could be fairly inexpensive and even disposable. Third, a compact telemetry system on any balloon will free up more room for the science portion of the payload. In response, a compact telemetry/termination system called the Micro-Instrumentation Package (MIP) was developed. The MIP provides uplink and downlink communications, an interface to the science, housekeeping information including global positioning system (GPS) position, and relays. Instead of a power-hungry microprocessor, the MIP's central consists of a microcontroller. Microcontrollers are lower power, easily programmed, and can be purchased for less than ten dollars. For uplink and downlink telemetry, the MIP uses an LOS serial transceiver and an Iridium unit for OTH flights. A relay deck is also included for powering subsystems and for flight termination. Furthermore, the science will be able to interface to the MIP through a serial connection, although the data rates for the science interface will be limited compared to those of standard telemetry support packages. Overall, the MIP provides the basic necessities for the safe operation of a balloon flight without the weight and the expense of the current CSBF telemetry support packages. This paper will explain more about CSBF operations and delve further into the MIP development, testing and capabilities.
Eliminating Inappropriate Telemetry Monitoring: An Evidence-Based Implementation Guide.
Yeow, Raymond Y; Strohbehn, Garth W; Kagan, Calvin M; Petrilli, Christopher M; Krishnan, Jamuna K; Edholm, Karli; Sussman, L Scott; Blanck, Jaime F; Popa, Remus I; Pahwa, Amit K
2018-06-04
In-hospital continuous electrocardiographic monitoring, commonly referred to as telemetry, has allowed for rapid recognition of life-threatening conditions, including complex arrhythmias and myocardial ischemia. However, inappropriate use can lead to unnecessary downstream testing from "false alarms," which in turn affects clinician efficiency and increases health care costs without benefiting patients. For these reasons, the Society of Hospital Medicine's Choosing Wisely campaign recommended use of a protocol-driven discontinuation of telemetry. The American Heart Association (AHA) developed a set of Practice Standards for the appropriate use of telemetry monitoring in 2004, which they updated in 2017. Unfortunately, the AHA Practice Standards have not been widely adopted-with as many as 43% of monitored patients lacking a recommended indication for monitoring. Thus, we created an overview discussing the safety and efficacy of incorporating the AHA Practice Standards and a review of studies highlighting their successful incorporation within patient care workflow. We conclude by outlining an "implementation blueprint" for health system professionals and administrators seeking to change their institution's culture of telemetry use. As the health care landscape continues to shift, enacting high-value initiatives that improve patient safety and efficiency of care will be critical.
Space Technology for Patient Monitoring
NASA Technical Reports Server (NTRS)
1989-01-01
A contract for the development of an astronaut monitoring system in the early days of the space program provided Mennen Medical, Inc. with a foundation in telemetry that led to the development of a computerized medical electronic system used by hospitals. Mennen was the first company to adopt solid state design in patient monitoring and to offer multipatient telemetry monitoring. Telemetry converts instrument data to electrical signals and relays them to a remote receiver where they are displayed. From a central station, a nurse can monitor several patients. Company products include VISTA systems and Horizon 2000 Monitor.
NASA Technical Reports Server (NTRS)
Miranda, Felix A.; Simons, Rainee N.; Haal, David G.
2004-01-01
In this paper we discuss a novel radio frequency (RF) telemetry concept for biomedical applications. The concept consists of a miniaturized spiral inductor/antenna for bio-MEMS sensors and an external pick-up antenna integrated into a handheld device. The measured relative signal strength in the presence of biological phantoms ranged from 5.9 to 7.5 dB for antenna separations of 5 and 10 cm. These relative signal strengths are easily measurable, therefore validating the RF telemetry concept for biomedical applications.
2012-05-01
Settling Time Test .............................................................................................. 3-16 3.13 Overload Recovery Test...6-7 6.7 Inter-message Gap Time Test...6-8 6.8 Response Time Test ............................................................................................. 6-9 6.9
Dias, C A R; Queirogas, V L; Pedersoli, M A
2015-01-01
Two groups of pygmy marmoset (Cebuella pygmaea) were rescued along the left bank of the Madeira River during the formation of Santo Antônio Hydroelectric Dam reservoir in the state of Rondônia, Northern Brazil. Reintroduction of both groups occurred in areas of open Tropical rainforest located within the project´s Permanent Preservation Area. A post-release monitoring was conducted for three months using radio-telemetry. Individuals of each group remained together and settled in stable home ranges near their respective release sites. The mortality rate of translocated animals was about 7%. This seems to be the first report documenting the complete group translocation of C. pygmaea and the first to successfully employ radio-telemetry techniques in monitoring this species. This study demonstrated the feasibility of translocation and the use of radio-telemetry in monitoring C. pygmaea.
NASA Astrophysics Data System (ADS)
Sakai, H.
1985-09-01
The SCRIBE experiments were conducted for the purpose of observing the atmospheric infrared emission by using a cryogenic interferometer spectrometer mounted on a balloon-borne platform. The data collected during the flight by the spectrometer were transmitted through the radio telemetry link and were received at the ground station of Holloman AFB where these flights were monitored. They were recorded on analog 1/2 in magnetic tapes running at 60 ips. By playing back these tapes, the telemetry signal transmitted from the balloon-borne package was reporduced at our site for processing efforts to retrieve the interferogram data out of the played-back telemetry signal, and to recover the spectral data corresponding to radiation emitted by the atmosphere were the main objective of this work. In addition to the Holloman tapes, a mobile telemetry signal-receiving unit of AFGL was used to record the flight data on similar analog tapes for the Jul-05-1984 flight launched from Roswell, New Mexico.
CASSIUS: The Cassini Uplink Scheduler
NASA Technical Reports Server (NTRS)
Bellinger, Earl
2012-01-01
The Cassini Uplink Scheduler (CASSIUS) is cross-platform software used to generate a radiation sequence plan for commands being sent to the Cassini spacecraft. Because signals must travel through varying amounts of Earth's atmosphere, several different modes of constant telemetry rates have been devised. These modes guarantee that the spacecraft and the Deep Space Network agree with respect to the data transmission rate. However, the memory readout of a command will be lost if it occurs on a telemetry mode boundary. Given a list of spacecraft message files as well as the available telemetry modes, CASSIUS can find an uplink sequence that ensures safe transmission of each file. In addition, it can predict when the two on-board solid state recorders will swap. CASSIUS prevents data corruption by making sure that commands are not planned for memory readout during telemetry rate changes or a solid state recorder swap.
NASA Technical Reports Server (NTRS)
Rice, J. Kevin
2013-01-01
The XTCE GOVSAT software suite contains three tools: validation, search, and reporting. The Extensible Markup Language (XML) Telemetric and Command Exchange (XTCE) GOVSAT Tool Suite is written in Java for manipulating XTCE XML files. XTCE is a Consultative Committee for Space Data Systems (CCSDS) and Object Management Group (OMG) specification for describing the format and information in telemetry and command packet streams. These descriptions are files that are used to configure real-time telemetry and command systems for mission operations. XTCE s purpose is to exchange database information between different systems. XTCE GOVSAT consists of rules for narrowing the use of XTCE for missions. The Validation Tool is used to syntax check GOVSAT XML files. The Search Tool is used to search (i.e. command and telemetry mnemonics) the GOVSAT XML files and view the results. Finally, the Reporting Tool is used to create command and telemetry reports. These reports can be displayed or printed for use by the operations team.
Advanced Metallic Air Vehicle Structure Program
1976-08-01
r-Ř Z- cq rXH H ý-q P7 PI-I .rý17 > r4 %. I~tf Ifr )~ 1 m L cc -I O’t %D-Z r- 0~ c-4) 0ff f ~ ~ L ~ L~f a’oY C ca \\D oIt 01\\ mc I’DJ c-o ’-4<tD -zt...FIGURE~COV 2..111 HET O FASTNERHOLEIDETIFIATIN - PPE UCOER 87;B 7- 276 C-1 UPPER 5URFACE Tyl so L2 2.O-t- y ESP AT APPLED O AVSUR \\L1 Lt OF02O~ X72
NASA Astrophysics Data System (ADS)
Royer, P.; De Ridder, J.; Vandenbussche, B.; Regibo, S.; Huygen, R.; De Meester, W.; Evans, D. J.; Martinez, J.; Korte-Stapff, M.
2016-07-01
We present the first results of a study aimed at finding new and efficient ways to automatically process spacecraft telemetry for automatic health monitoring. The goal is to reduce the load on the flight control team while extending the "checkability" to the entire telemetry database, and provide efficient, robust and more accurate detection of anomalies in near real time. We present a set of effective methods to (a) detect outliers in the telemetry or in its statistical properties, (b) uncover and visualise special properties of the telemetry and (c) detect new behavior. Our results are structured around two main families of solutions. For parameters visiting a restricted set of signal values, i.e. all status parameters and about one third of all the others, we focus on a transition analysis, exploiting properties of Poincare plots. For parameters with an arbitrarily high number of possible signal values, we describe the statistical properties of the signal via its Kernel Density Estimate. We demonstrate that this allows for a generic and dynamic approach of the soft-limit definition. Thanks to a much more accurate description of the signal and of its time evolution, we are more sensitive and more responsive to outliers than the traditional checks against hard limits. Our methods were validated on two years of Venus Express telemetry. They are generic for assisting in health monitoring of any complex system with large amounts of diagnostic sensor data. Not only spacecraft systems but also present-day astronomical observatories can benefit from them.
X-33 Telemetry Best Source Selection, Processing, Display, and Simulation Model Comparison
NASA Technical Reports Server (NTRS)
Burkes, Darryl A.
1998-01-01
The X-33 program requires the use of multiple telemetry ground stations to cover the launch, ascent, transition, descent, and approach phases for the flights from Edwards AFB to landings at Dugway Proving Grounds, UT and Malmstrom AFB, MT. This paper will discuss the X-33 telemetry requirements and design, including information on fixed and mobile telemetry systems, best source selection, and support for Range Safety Officers. A best source selection system will be utilized to automatically determine the best source based on the frame synchronization status of the incoming telemetry streams. These systems will be used to select the best source at the landing sites and at NASA Dryden Flight Research Center to determine the overall best source between the launch site, intermediate sites, and landing site sources. The best source at the landing sites will be decommutated to display critical flight safety parameters for the Range Safety Officers. The overall best source will be sent to the Lockheed Martin's Operational Control Center at Edwards AFB for performance monitoring by X-33 program personnel and for monitoring of critical flight safety parameters by the primary Range Safety Officer. The real-time telemetry data (received signal strength, etc.) from each of the primary ground stations will also be compared during each nu'ssion with simulation data generated using the Dynamic Ground Station Analysis software program. An overall assessment of the accuracy of the model will occur after each mission. Acknowledgment: The work described in this paper was NASA supported through cooperative agreement NCC8-115 with Lockheed Martin Skunk Works.
Telemetry Standards, RCC Standard 106-17, Chapter 28, RF Network Management
2017-07-01
Telemetry Standards, RCC Standard 106-17 Chapter 28, July 2017 i CHAPTER 28 RF Network Management Table of Contents Acronyms... Management ............................................................................... 28-1 28.1 Introduction...28-1 28.2 RF Network Management Concepts and Definitions
Design of Deformation Monitoring System for Volcano Mitigation
NASA Astrophysics Data System (ADS)
Islamy, M. R. F.; Salam, R. A.; Munir, M. M.; Irsyam, M.; Khairurrijal
2016-08-01
Indonesia has many active volcanoes that are potentially disastrous. It needs good mitigation systems to prevent victims and to reduce casualties from potential disaster caused by volcanoes eruption. Therefore, the system to monitor the deformation of volcano was built. This system employed telemetry with the combination of Radio Frequency (RF) communications of XBEE and General Packet Radio Service (GPRS) communication of SIM900. There are two types of modules in this system, first is the coordinator as a parent and second is the node as a child. Each node was connected to coordinator forming a Wireless Sensor Network (WSN) with a star topology and it has an inclinometer based sensor, a Global Positioning System (GPS), and an XBEE module. The coordinator collects data to each node, one a time, to prevent collision data between nodes, save data to SD Card and transmit data to web server via GPRS. Inclinometer was calibrated with self-built in calibrator and tested in high temperature environment to check the durability. The GPS was tested by displaying its position in web server via Google Map Application Protocol Interface (API v.3). It was shown that the coordinator can receive and transmit data from every node to web server very well and the system works well in a high temperature environment.
An OTA-C filter for ECG acquisition systems with highly linear range and less passband attenuation
NASA Astrophysics Data System (ADS)
Jihai, Duan; Chuang, Lan; Weilin, Xu; Baolin, Wei
2015-05-01
A fifth order operational transconductance amplifier-C (OTA-C) Butterworth type low-pass filter with highly linear range and less passband attenuation is presented for wearable bio-telemetry monitoring applications in a UWB wireless body area network. The source degeneration structure applied in typical small transconductance circuit is improved to provide a highly linear range for the OTA-C filter. Moreover, to reduce the passband attenuation of the filter, a cascode structure is employed as the output stage of the OTA. The OTA-based circuit is operated in weak inversion due to strict power limitation in the biomedical chip. The filter is fabricated in a SMIC 0.18-μm CMOS process. The measured results for the filter have shown a passband gain of -6.2 dB, while the -3-dB frequency is around 276 Hz. For the 0.8 VPP sinusoidal input at 100 Hz, a total harmonic distortion (THD) of -56.8 dB is obtained. An electrocardiogram signal with noise interference is fed into this chip to validate the function of the designed filter. Project supported by the National Natural Science Foundation of China (Nos. 61161003, 61264001, 61166004) and the Guangxi Natural Science Foundation (No. 2013GXNSFAA019333).
NASA Technical Reports Server (NTRS)
Nessel, James A.; Kory, Carol L.; Lambert, Kevin M.; Acosta, Roberto J.
2006-01-01
Short Backfire Antennas (SBAs) are widely utilized for mobile satellite communications, tracking, telemetry, and wireless local area network (WLAN) applications due to their compact structure and excellent radiation characteristics [1-3]. Typically, these SBA s consist of an excitation element (i.e., a half-wavelength dipole), a reflective bottom plane, a planar sub-reflector located above the "exciter", and an outer circular rim. This configuration is capable of achieving gains on the order of 13-15 dBi, but with relatively narrow bandwidths (approx.3%-5%), making it incompatible with the requirements of the next generation enhanced Tracking and Data Relay Satellite System-Continuation (TDRSS-C) Multiple Access (MA) array [1]. Several attempts have been made to enhance the bandwidth performance of the common dipole-fed SBA by employing various other feeding mechanisms (e.g., waveguide, slot) with moderate success [4-5]. In this paper, a novel method of using a microstrip patch is employed for the first time to excite an SBA. The patch element is fed via two H-shaped slots electromagnetically coupled to a broadband hybrid coupler to maintain a wide bandwidth, as well as provide for dual circular polarization capabilities.
Development of Self-Powered Wireless Structural Health Monitoring (SHM) for Wind Turbine Blades
NASA Astrophysics Data System (ADS)
Lim, Dong-Won
Wind turbine blade failure can lead to unexpected power interruptions. Monitoring wind turbine blades is important to ensure seamless electricity delivery from power generation to consumers. Structural health monitoring (SHM) enables early recognition of structural problems so that the safety and reliability of operation can be enhanced. This dissertation focuses on the development of a wireless SHM system for wind turbine blades. The sensor is comprised of a piezoelectric energy harvester (EH) and a telemetry unit. The sensor node is mounted on the blade surface. As the blade rotates, the blade flexes, and the energy harvester captures the strain energy on the blade surface. Once sufficient electricity is captured, a pulse is sent from the sensing node to a gateway. Then, a central monitoring algorithm processes a series of pulses received from all three blades. This wireless SHM, which uses commercially available components, can be retrofitted to existing turbines. The harvested energy for sensing can be estimated in terms of two factors: the available strain energy and conversion efficiency. The available strain energy was evaluated using the FAST (Fatigue, Aerodynamics, Structures, and Turbulence) simulator. The conversion efficiency was studied analytically and experimentally. An experimental set-up was designed to mimic the expected strain frequency and amplitude for rotor blades. From a series of experiments, the efficiency of a piezoelectric EH at a typical rotor speed (0.2 Hz) was approximately 0.5%. The power requirement for sending one measurement (280 muJ) can be achieved in 10 minutes. Designing a detection algorithm is challenging due to this low sampling rate. A new sensing approach-the timing of pulses from the transmitter-was introduced. This pulse timing, which is tied to the charging time, is indicative of the structural health. The SHM system exploits the inherent triple redundancy of the three blades. The timing data of the three blades are compared to discern an outlier, corresponding to a damaged blade. Two types of post-processing of pulses were investigated: (1) comparing the ratios of signal timings (i.e. transmission ratio); and (2) comparing the difference between signal timings (i.e. residuals). For either method, damage is indicated when the energy ratio or residual exceeds a threshold level. When residuals are used to detect damage, performance measures such as the false alarm rate and detection probability can also be imposed. The SHM algorithms were evaluated using strain energy data from a 2.5 MW wind turbine.
Launch mission summary and sequence of events Telesat-F(anik-D1)/Delta-164
NASA Technical Reports Server (NTRS)
1982-01-01
The launch vehicle, spacecraft, and mission are summarized. Launch window information, vehicle telemetry coverage, real time data flow, telemetry coverage by station, selected trajectory information, and a brief sequence of flight events are included.
NASA Technical Reports Server (NTRS)
Rosatino, S. A.; Westbrook, R. M.
1979-01-01
Miniature, individual crystal-controlled RF transmitters located in EMG pressure sensors simplifies multichannel EMG telemetry for electronic gait monitoring. Transmitters which are assigned operating frequencies within 174 - 216 MHz band have linear frequency response from 20 - 2000 Hz and operate over range of 15 m.
Microelectronic bioinstrumentation systems
NASA Technical Reports Server (NTRS)
Ko, W. H.; Hynecek, J.
1975-01-01
The possibility of using RF fields to power biologically implanted transmitters used in biomedical experiments was investigated. This approach would be especially useful when animal subjects are strapped in chairs or confined in cages. A telemetry system using an external source of energy has the additional advantage of not being limited in operation by battery lifetime and can therefore operate for virtually infinite lengths of time. A description of a system based on this principle is given. Progress in the development of battery-driven transmitters is also reported, including an ingestible temperature telemetry system and a resistance-to-pulse frequency convertor for implantable temperature telemetry systems.
Space-Based Telemetry and Range Safety (STARS) Study
NASA Technical Reports Server (NTRS)
Hogie, Keith; Crisuolo, Ed; Parise, Ron
2004-01-01
This presentation will describe the design, development, and testing of a system to collect telemetry, format it into UDP/IP packets, and deliver it to a ground test range using standard IP technologies over a TDRSS link. This presentation will discuss the goal of the STARS IP Formatter along with the overall design. It will also present performance results of the current version of the IP formatter. Finally, it will discuss key issues for supporting constant rate telemetry data delivery when using standard components such as PCI/104 processors, the Linux operating system, Internet Protocols, and synchronous serial interfaces.
Acquisition and analysis of primate physiologic data for the Space Shuttle
NASA Astrophysics Data System (ADS)
Eberhart, Russell C.; Hogrefe, Arthur F.; Radford, Wade E.; Sanders, Kermit H.; Dobbins, Roy W.
1988-03-01
This paper describes the design and prototypes of the Physiologic Acquisition and Telemetry System (PATS), which is a multichannel system, designed for large primates, for the data acquisition, telemetry, storage, and analysis of physiological data. PATS is expected to acquire data from units implanted in the abdominal cavities of rhesus monkeys that will be flown aboard the Spacelab. The system will telemeter both stored and real-time internal physiologic measurements to an external Flight Support Station (FSS) computer system. The implanted Data Acquition and Telemetry Subsystem subunit will be externally activated, controlled and reprogrammed from the FSS.
New generation of telemetry systems using CCSDS packetisation - A prototype implementation
NASA Astrophysics Data System (ADS)
Sotta, J. P.; Held, K.
1988-07-01
The system described herein was developed under ESA contract to support the introduction of new telemetry standards based on the packetized telemetry data concept. These standards were derived from recommendations in the frame of work of CCSDS, an inter-Agency committee that counts among its members most European National Agencies, ESA, NASA as well as Japanese NASDA, Indian ISRO and Brazilian INPE and having as objective to facilitate cross-support for space missions. The development is based on the present generation of ESA on-board equipment (OBDH) subsystem and is fully compatible with OBDH bus interfaces and transfer protocol.
Fish, Richard E; Foster, Melanie L; Gruen, Margaret E; Sherman, Barbara L; Dorman, David C
2017-01-01
Safety pharmacology studies in dogs often integrate behavioral assessments made using video recording with physiologic measurements collected by telemetry. However, whether merely wearing the telemetry vest affects canine behavior and other parameters has not been evaluated. This pilot study assessed the effect of a telemetry vest on behavioral and physiologic responses to an environmental stressor, the sounds of a thunderstorm, in Labrador retrievers. Dogs were assigned to one of 2 experimental groups (Vest and No-Vest, n = 8 dogs per group) by using a matched pairs design, with a previously determined, sound-associated anxiety score as the blocking variable. Dogs were individually retested with the same standardized sound stimulus (thunderstorm) in an open-field arena, and their behavioral responses were video recorded. Video analysis of locomotor activity and anxiety-related behavior and manual determination of heart rate and body temperature were performed; results were compared between groups. Vest wearing did not affect total locomotor activity or rectal body temperature but significantly decreased heart rate by 8% and overall mean anxiety score by 34% during open-field test sessions. Our results suggest that the use of telemetry vests in dogs influences the measurement of physiologic parameters and behaviors that are assessed in safety pharmacology studies. PMID:28724487
Krasowski, Michael J; Prokop, Norman F; Flatico, Joseph M; Greer, Lawrence C; Jenkins, Phillip P; Neudeck, Philip G; Chen, Liangyu; Spina, Danny C
2013-01-01
The Communications Interface Board (CIB) is an improved communications architecture that was demonstrated on the International Space Station (ISS). ISS communication interfaces allowing for real-time telemetry and health monitoring require a significant amount of development. The CIB simplifies the communications interface to the ISS for real-time health monitoring, telemetry, and control of resident sensors or experiments. With a simpler interface available to the telemetry bus, more sensors or experiments may be flown. The CIB accomplishes this by acting as a bridge between the ISS MIL-STD-1553 low-rate telemetry (LRT) bus and the sensors allowing for two-way command and telemetry data transfer. The CIB was designed to be highly reliable and radiation hard for an extended flight in low Earth orbit (LEO) and has been proven with over 40 months of flight operation on the outside of ISS supporting two sets of flight experiments. Since the CIB is currently operating in flight on the ISS, recent results of operations will be provided. Additionally, as a vehicle health monitoring enabling technology, an overview and results from two experiments enabled by the CIB will be provided. Future applications for vehicle health monitoring utilizing the CIB architecture will also be discussed.
Krasowski, Michael J.; Prokop, Norman F.; Flatico, Joseph M.; Greer, Lawrence C.; Jenkins, Phillip P.; Neudeck, Philip G.; Chen, Liangyu; Spina, Danny C.
2013-01-01
The Communications Interface Board (CIB) is an improved communications architecture that was demonstrated on the International Space Station (ISS). ISS communication interfaces allowing for real-time telemetry and health monitoring require a significant amount of development. The CIB simplifies the communications interface to the ISS for real-time health monitoring, telemetry, and control of resident sensors or experiments. With a simpler interface available to the telemetry bus, more sensors or experiments may be flown. The CIB accomplishes this by acting as a bridge between the ISS MIL-STD-1553 low-rate telemetry (LRT) bus and the sensors allowing for two-way command and telemetry data transfer. The CIB was designed to be highly reliable and radiation hard for an extended flight in low Earth orbit (LEO) and has been proven with over 40 months of flight operation on the outside of ISS supporting two sets of flight experiments. Since the CIB is currently operating in flight on the ISS, recent results of operations will be provided. Additionally, as a vehicle health monitoring enabling technology, an overview and results from two experiments enabled by the CIB will be provided. Future applications for vehicle health monitoring utilizing the CIB architecture will also be discussed. PMID:23983621
Telemetry research on elusive wildlife: A synthesis of studies on giant pandas.
Connor, Thomas; Hull, Vanessa; Liu, Jianguo
2016-07-01
Telemetry studies that track animals through space and time can lead to advances in scientific understanding that are vital in conservation efforts. For example, telemetry studies of the giant panda (Ailuropoda melanoleuca) have shed light on many aspects of panda biology, but small sample sizes in each separate study make it difficult to draw broad conclusions. To overcome this problem we conducted the first synthesis of all 5 panda telemetry studies conducted to date. Using these data we investigated patterns in 6 main topics: home range, space-use interactions, core areas, movement patterns, seasonal migration and natal dispersal. We found that panda home range sizes do not vary between 2 main mountain ranges (Qionglai and Qinling), as was previously believed. Our results also suggest that female pandas increase their movement in the mating season: a behavior typically attributed only to males. We found and summarized telemetry and genetic evidence for female natal dispersal in the giant panda. Our synthesis highlights the need for additional research relating panda behavior to human disturbance factors, and can aid future studies on giant pandas as well as other species. © 2016 International Society of Zoological Sciences, Institute of Zoology/Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.
Fish, Richard E; Foster, Melanie L; Gruen, Margaret E; Sherman, Barbara L; Dorman, Davidc C
2017-07-01
Safety pharmacology studies in dogs often integrate behavioral assessments made using video recording with physiologic measurements collected by telemetry. However, whether merely wearing the telemetry vest affects canine behavior and other parameters has not been evaluated. This pilot study assessed the effect of a telemetry vest on behavioral and physiologic responses to an environmental stressor, the sounds of a thunderstorm, in Labrador retrievers. Dogs were assigned to one of 2 experimental groups (Vest and No-Vest, n = 8 dogs per group) by using a matched pairs design, with a previously determined, sound-associated anxiety score as the blocking variable. Dogs were individually retested with the same standardized sound stimulus (thunderstorm) in an open-field arena, and their behavioral responses were video recorded. Video analysis of locomotor activity and anxiety-related behavior and manual determination of heart rate and body temperature were performed; results were compared between groups. Vest wearing did not affect total locomotor activity or rectal body temperature but significantly decreased heart rate by 8% and overall mean anxiety score by 34% during open-field test sessions. Our results suggest that the use of telemetry vests in dogs influences the measurement of physiologic parameters and behaviors that are assessed in safety pharmacology studies.
Microelectronic bioinstrumentation systems
NASA Technical Reports Server (NTRS)
Ko, W. H.
1976-01-01
Progress was made in the development of an RF cage, a single channel RF powered ECG telemetry system, and a three channel RF powered ECG, aortic blood pressure, and body temperature telemetry system. Encapsulation materials for chronic implantation of electronic circuits in the body were also evaluated.
NASA Astrophysics Data System (ADS)
Selznick, S. H.
2017-06-01
Herein we describe an architecture developed for processing engineering and science data for the OSIRIS-REx mission. The architecture is soup-to-nuts, starting with raw telemetry and ending with submission to PDS.
The prevalence of eosinophilic esophagitis in pediatric patients with IgE-mediated food allergy
Hill, David A.; Dudley, Jesse W.; Spergel, Jonathan M.
2017-01-01
BACKGROUND Eosinophilic esophagitis (EoE) is an allergic inflammatory disease that is triggered by food allergens and characterized by progressive esophageal dysfunction. Recently, EoE has been identified in patients undergoing oral immunotherapy (OIT) for IgE-mediated food allergy, suggesting an association. OBJECTIVE We sought to ascertain whether significant associations exist between IgE-mediated food allergies and EoE. METHODS Utilizing analysis of EMR data and manual chart review, we examined our sub-specialty care network of 35,528 children and adolescents to identify and characterize patients with IgE-mediated, and EoE food allergy. The most common food allergens were defined, and the prevalence of EoE in patients with IgE-mediated food allergy was determined. Logistic regression was used to measure the extent to which IgE-mediated food allergy to specific foods is associated with EoE. RESULTS The most common causes of EoE were milk, grains, meats, peanut, tree nuts, egg, and soy, an allergen pattern that is distinct from that of IgE-mediated food allergy. The prevalence of EoE in patients with IgE-mediated food allergy was higher than that reported in the general population (4.7% vs 0.04%). The distribution of IgE-mediated food allergens in patients with EoE was similar to that of the general population, and IgE-mediated allergy to egg (2.27; 1.91–2.64), milk (4.19; 3.52–4.97), or shellfish (1.55; 1.24–1.92) was significantly associated with EoE diagnosis. CONCLUSIONS Our findings support a clinical association between these conditions that has implications for the management of children with food allergy, and particular relevance to patients undergoing OIT. PMID:28042003
Omalizumab facilitates rapid oral desensitization for peanut allergy
MacGinnitie, Andrew J.; Rachid, Rima; Gragg, Hana; Little, Sara V; Lakin, Paul; Cianferoni, Antonella; Heimall, Jennifer; Makhija, Melanie; Robison, Rachel; Chinthrajah, R. Sharon; Lee, John; Lebovidge, Jennifer; Dominguez, Tina; Rooney, Courtney; Lewis, Megan Ott; Koss, Jennifer; Burke-Roberts, Elizabeth; Chin, Kimberly; Logvinenko, Tanya; Pongracic, Jacqueline A.; Umetsu, Dale T.; Spergel, Jonathan; Nadeau, Kari C.; Schneider, Lynda C.
2017-01-01
Background Peanut oral immunotherapy (OIT) is a promising approach to peanut allergy but reactions are frequent and some patients cannot be desensitized. The anti-IgE medication omalizumab (Xolair) may allow more rapid peanut updosing and decrease reactions. Objective To evaluate if omalizumab facilitated rapid peanut desensitization in highly allergic patients. Methods Thirty-seven subjects were randomized to omalizumab (n=29) or placebo (n=8). After 12 weeks of treatment subjects underwent a rapid one-day desensitization of up to 250 mg of peanut protein, followed by weekly increases up to 2000 mg. Omalizumab was then discontinued and subjects continued on 2000 mg of peanut protein. They underwent an open challenge to 4000 mg peanut protein twelve weeks after stopping study drug. If tolerated, subjects continued on 4000 mg of peanut protein daily. Results The median peanut dose tolerated on the initial desensitization day was 250 mg for omalizumab versus 22.5 mg for placebo treated subject. Subsequently 23 of 29 (79%) subjects randomized to omalizumab tolerated 2000 mg peanut protein 6 weeks after stopping omalizumab versus 1 of 8 (12%) receiving placebo (p<0.01). Twenty-three subjects on omalizumab versus 1 on placebo passed the 4000 mg food challenge. Overall reaction rates were not significantly lower in omalizumab versus placebo treated subjects (OR=0.57 p=0.15), although omalizumab treated subjects were exposed to much higher doses of peanut. Conclusion Omalizumab allows subjects with peanut allergy to be rapidly desensitized over as little as 8 weeks of peanut OIT. In the majority of subjects, this desensitization is sustained after omalizumab is discontinued. Additional studies will help clarify which patients would benefit most from this approach. PMID:27609658
Tail-Cuff Technique and Its Influence on Central Blood Pressure in the Mouse.
Wilde, Elena; Aubdool, Aisah A; Thakore, Pratish; Baldissera, Lineu; Alawi, Khadija M; Keeble, Julie; Nandi, Manasi; Brain, Susan D
2017-06-27
Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Telemetry-based mortality estimates of juvenile spot in two North Carolina estuarine creeks
Friedl, Sarah E.; Buckel, Jeffery A.; Hightower, Joseph E.; Scharf, Frederick S.; Pollock, Kenneth H.
2013-01-01
We estimated natural mortality rates (M) of age-1 Spot Leiostomus xanthurus by using a sonic telemetry approach. Sonic transmitters were surgically implanted into a total of 123 age-1 Spot in two North Carolina estuarine creeks during spring 2009 and 2010, and the fish were monitored by using a stationary acoustic receiver array and manual tracking. Fates of telemetered Spot were inferred based on telemetry information from estimated locations and swimming speeds. Potential competitors of age-1 Spot were assessed through simultaneous otter trawl sampling, while potential predators of Spot were collected using gill nets and trammel nets. The number of inferred natural mortalities was zero in 2009 (based on 29 telemetered Spot at risk) and four in 2010 (based on 52 fish at risk), with fish being at risk for up to about 70 d each year. Catches of potential competitors or predators did not differ between years, and age-1 Spot were not found in analyzed stomach contents of potential predators. Our estimated 30-d M of 0.03 (95% credible interval = 0.01–0.07) was lower than that predicted from weight-based (M = 0.07) and life-history-based (M = 0.06–0.36) estimates. Our field-based estimate of M for age-1 Spot in this estuarine system can assist in the assessment and management of Spot by allowing a direct comparison with M-values predicted from fish size or life history characteristics. The field telemetry and statistical analysis techniques developed here provide guidance for future telemetry studies of relatively small fish in open, dynamic habitat systems, as they highlight strengths and weaknesses of using a telemetry approach to estimate M.
NASA Astrophysics Data System (ADS)
Kerley, Dan; Smith, Malcolm; Dunn, Jennifer; Herriot, Glen; Véran, Jean-Pierre; Boyer, Corinne; Ellerbroek, Brent; Gilles, Luc; Wang, Lianqi
2016-08-01
The Narrow Field Infrared Adaptive Optics System (NFIRAOS) is the first light Adaptive Optics (AO) system for the Thirty Meter Telescope (TMT). A critical component of NFIRAOS is the Real-Time Controller (RTC) subsystem which provides real-time wavefront correction by processing wavefront information to compute Deformable Mirror (DM) and Tip/Tilt Stage (TTS) commands. The National Research Council of Canada - Herzberg (NRC-H), in conjunction with TMT, has developed a preliminary design for the NFIRAOS RTC. The preliminary architecture for the RTC is comprised of several Linux-based servers. These servers are assigned various roles including: the High-Order Processing (HOP) servers, the Wavefront Corrector Controller (WCC) server, the Telemetry Engineering Display (TED) server, the Persistent Telemetry Storage (PTS) server, and additional testing and spare servers. There are up to six HOP servers that accept high-order wavefront pixels, and perform parallelized pixel processing and wavefront reconstruction to produce wavefront corrector error vectors. The WCC server performs low-order mode processing, and synchronizes and aggregates the high-order wavefront corrector error vectors from the HOP servers to generate wavefront corrector commands. The Telemetry Engineering Display (TED) server is the RTC interface to TMT and other subsystems. The TED server receives all external commands and dispatches them to the rest of the RTC servers and is responsible for aggregating several offloading and telemetry values that are reported to other subsystems within NFIRAOS and TMT. The TED server also provides the engineering GUIs and real-time displays. The Persistent Telemetry Storage (PTS) server contains fault tolerant data storage that receives and stores telemetry data, including data for Point-Spread Function Reconstruction (PSFR).
Peterson, Sean M.; Streby, Henry M.; Lehman, Justin A.; Kramer, Gunnar R.; Fish, Alexander C.; Andersen, David E.
2015-01-01
We compared the efficacy of standard nest-searching methods with finding nests via radio-tagged birds to assess how search technique influenced our determination of nest-site characteristics and nest success for Golden-winged Warblers (Vermivora chrysoptera). We also evaluated the cost-effectiveness of using radio-tagged birds to find nests. Using standard nest-searching techniques for 3 populations, we found 111 nests in locations with habitat characteristics similar to those described in previous studies: edges between forest and relatively open areas of early successional vegetation or shrubby wetlands, with 43% within 5 m of forest edge. The 83 nests found using telemetry were about half as likely (23%) to be within 5 m of forest edge. We spent little time searching >25 m into forest because published reports state that Golden-winged Warblers do not nest there. However, 14 nests found using telemetry (18%) were >25 m into forest. We modeled nest success using nest-searching method, nest age, and distance to forest edge as explanatory variables. Nest-searching method explained nest success better than nest age alone; we estimated that nests found using telemetry were 10% more likely to fledge young than nests found using standard nest-searching methods. Although radio-telemetry was more expensive than standard nest searching, the cost-effectiveness of both methods differed depending on searcher experience, amount of equipment owned, and bird population density. Our results demonstrate that telemetry can be an effective method for reducing bias in Golden-winged Warbler nest samples, can be cost competitive with standard nest-searching methods in some situations, and is likely to be a useful approach for finding nests of other forest-nesting songbirds.
21 CFR 882.1855 - Electroencephalogram (EEG) telemetry system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electroencephalogram (EEG) telemetry system. 882.1855 Section 882.1855 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1855...
21 CFR 882.1855 - Electroencephalogram (EEG) telemetry system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroencephalogram (EEG) telemetry system. 882.1855 Section 882.1855 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1855...
An Overview of the Beacon Monitor Operations Technology
NASA Technical Reports Server (NTRS)
Sue, Miles K.; Wyatt, E. Jay; Foster, Mike; Schlutsmeyer, Alan; Sherwood, Rob
1997-01-01
This paper summarizes the end-to-end design of a technology for low cost mission operations. Cost savings is achieved by reducing the total volume of downlinked engineering telemetry by decreasing the frequency of telemetry acquisition and the volume of data received per pass.
BROADBAND DIGITAL GEOPHYSICAL TELEMETRY SYSTEM.
Seeley, Robert L.; Daniels, Jeffrey J.
1984-01-01
A system has been developed to simultaneously sample and transmit digital data from five remote geophysical data receiver stations to a control station that processes, displays, and stores the data. A microprocessor in each remote station receives commands from the control station over a single telemetry channel.
Evaluating CMA Equalization of SOQPSK-TG for Aeronautical Telemetry
2015-03-01
Program through the U.S. Army Program Executive Office for Simulation, Training and Instrumentation (PEO STRI) under contract W900KK-13-C-0026 ( PAQ ...Report: Preamble assisted equalization for aeronautical telemetry ( PAQ ),‖ Brigham Young University, Technical Report, 2014, submitted to the Spectrum
47 CFR 90.238 - Telemetry operations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... in the Public Safety and Industrial/Business Pools and in accordance with § 90.259). (e) In the 450... Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES PRIVATE LAND... MHz band (as available in the Public Safety Pool for bio-medical telemetry operations). (i) For...