Psychological and Metabolic Correlates of Obesity in African-Americans and Caucasians
2006-01-01
29% fat, and 14.6% protein. Ensure was available in vanilla, chocolate, strawberry, and butter pecan . This liquid meal has been used previously in...oxygen uptake, carbon dioxide production, and respiratory exchange ratio by open circuit spirometry (KB20-CosMed, Italy ). Maximal exercise test
A Comparison of Three Models of Ellipticdal Trainer
2006-08-31
expenditure . The conversion employed the oxygen uptake (VO2) measurements and RER. RER was needed because the caloric yield from consuming a milliliter...for the Nautilus Model E9 16. The energy expenditure during each bout was determined by open-circuit spirometry. Measured energy expenditure was... expenditure was steady state during this period. The relationship between the machine calorie reports and the measured energy expenditures was
Kumar, Amaravadi Sampath; Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan
2016-01-01
Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni's 't'-test. Exercise tolerance was analysed by Paired 'T'-test. Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1(st), 2(nd) and 3(rd) postoperative day when compared with preoperative day. On 4(th) and 5(th) postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance.
Kumar, Amaravadi Sampath; Augustine, Alfred Joseph; Pazhyaottayil, Zulfeequer Chundaanveetil; Ramakrishna, Anand; Krishnakumar, Shyam Krishnan
2016-01-01
Introduction Surgical procedures in abdominal area lead to changes in pulmonary function, respiratory mechanics and impaired physical capacity leading to postoperative pulmonary complications, which can affect up to 80% of upper abdominal surgery. Aim To evaluate the effects of flow and volume incentive spirometry on pulmonary function and exercise tolerance in patients undergoing open abdominal surgery. Materials and Methods A randomized clinical trial was conducted in a hospital of Mangalore city in Southern India. Thirty-seven males and thirteen females who were undergoing abdominal surgeries were included and allocated into flow and volume incentive spirometry groups by block randomization. All subjects underwent evaluations of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow (PEF). Preoperative and postoperative measurements were taken up to day 5 for both groups. Exercise tolerance measured by Six- Minute Walk Test during preoperative period and measured again at the time of discharge for both groups. Pulmonary function was analysed by post-hoc analysis and carried out using Bonferroni’s ‘t’-test. Exercise tolerance was analysed by Paired ‘T’-test. Results Pulmonary function (FVC, FEV1, and PEFR) was found to be significantly decreased in 1st, 2nd and 3rd postoperative day when compared with preoperative day. On 4th and 5th postoperative day the pulmonary function (FVC, FEV1, and PEFR) was found to be better preserved in both flow and volume incentive spirometry groups. The Six-Minute Walk Test showed a statistically significant improvement in pulmonary function on the day of discharge than in the preoperative period. In terms of distance covered, the volume- incentive spirometry group showed a greater statistically significant improvement from the preoperative period to the time of discharge than was exhibited by the flow incentive spirometry group. Conclusion Flow and volume incentive spirometry can be safely recommended to patients undergoing open abdominal surgery as there have been no adverse events recorded. Also, these led to a demonstrable improvement in pulmonary function and exercise tolerance. PMID:26894090
Heart rate variability and aerobic fitness.
De Meersman, R E
1993-03-01
Heart rate variability, a noninvasive marker of parasympathetic activity, diminishes with aging and is augmented after exercise training. Whether habitual exercise over time can attenuate this loss is unknown. This cross-sectional investigation compared 72 male runners, aged 15 to 83 to 72 age- and weight-matched sedentary control subjects for the amplitude of their heart rate variability. Heart rate variability was assessed during rest while subjects were breathing at a rate of 6 breaths per minute and at an augmented tidal volume (tidal volume = 30% of vital capacity). Fitness levels were assessed with on-line, open-circuit spirometry while subjects were performing an incremental stress test. Overall results between the two groups showed that the physically active group had significantly higher fitness levels (p < 0.001), which were associated with significantly higher levels of heart rate variability, when compared with their sedentary counterparts (p < 0.001). These findings provide suggestive evidence for habitual aerobic exercise as a beneficial modulator of heart rate variability in an aging population.
Tester Detects Steady-Short Or Intermittent-Open Circuits
NASA Technical Reports Server (NTRS)
Anderson, Bobby L.
1990-01-01
Momentary open circuits or steady short circuits trigger buzzer. Simple, portable, lightweight testing circuit sounds long-duration alarm when it detects steady short circuit or momentary open circuit in coaxial cable or other two-conductor transmission line. Tester sensitive to discontinuities lasting 10 microseconds or longer. Used extensively for detecting intermittent open shorts in accelerometer and extensometer cables. Also used as ordinary buzzer-type continuity checker to detect steady short or open circuits.
Haemoglobin saturation during incremental arm and leg exercise.
Powers, S. K.; Dodd, S.; Woodyard, J.; Beadle, R. E.; Church, G.
1984-01-01
There are few reports concerning the alterations in the percent of haemoglobin saturated with oxygen (%SO2) during non-steady state incremental exercise. Further, no data exist to describe the %SO2 changes during arm exercise. Therefore, the purpose of this study was made to assess the dynamic changes in %SO2 during incremental arm and leg work. Nine trained subjects (7 males and 2 females) performed incremental arm and leg exercise to exhaustion on an arm crank ergometer and a cycle ergometer, respectively. Ventilation and gas exchange measurements were obtained minute by minute via open circuit spirometry and changes in %SO2 were recorded via an ear oximeter. No significant difference (p greater than 0.05) existed between arm and leg work in end-tidal oxygen (PETO2), end-tidal carbon dioxide (PETCO2), or %SO2 when compared as a function of percent VO2 max. These results provide evidence that arterial O2 desaturation occurs in a similar fashion in both incremental arm and leg work with the greatest changes in %SO2 occurring at work rates greater than 70% VO2 max. PMID:6435715
NASA Technical Reports Server (NTRS)
Chern, Shy-Shiun (Inventor)
1981-01-01
A coaxial stub tuner assembly is comprised of a short circuit branch diametrically opposite an open circuit branch. The stub of the short circuit branch is tubular, and the stub of the open circuit branch is a rod which extends through the tubular stub into the open circuit branch. The rod is threaded at least at its outer end, and the tubular stub is internally threaded to receive the threads of the rod. The open circuit branch can be easily tuned by turning the threaded rod in the tubular stub to adjust the length of the rod extending into the open circuit branch.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-25
...; NIOSH-258] Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance... open-circuit self-contained breathing apparatus (OC- SCBA) remaining service-life indicators... ``Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance...
Bypassing An Open-Circuit Power Cell
NASA Technical Reports Server (NTRS)
Wannemacher, Harry E.
1994-01-01
Collection of bypass circuits enables battery consisting series string of cells to continue to function when one of its cells fails in open-circuit (high-resistance) condition. Basic idea simply to shunt current around defective cell to prevent open circuit from turning off battery altogether. Bypass circuits dissipate little power and are nearly immune to false activation.
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...
42 CFR 84.93 - Gas flow test; open-circuit apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200 liters...
42 CFR 84.93 - Gas flow test; open-circuit apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200 liters...
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...
Method of determining the open circuit voltage of a battery in a closed circuit
Brown, William E.
1980-01-01
The open circuit voltage of a battery which is connected in a closed circuit is determined without breaking the circuit or causing voltage upsets therein. The closed circuit voltage across the battery and the current flowing through it are determined under normal load and then a fractional change is made in the load and the new current and voltage values determined. The open circuit voltage is then calculated, according to known principles, from the two sets of values.
Commutation circuit for an HVDC circuit breaker
Premerlani, William J.
1981-01-01
A commutation circuit for a high voltage DC circuit breaker incorporates a resistor capacitor combination and a charging circuit connected to the main breaker, such that a commutating capacitor is discharged in opposition to the load current to force the current in an arc after breaker opening to zero to facilitate arc interruption. In a particular embodiment, a normally open commutating circuit is connected across the contacts of a main DC circuit breaker to absorb the inductive system energy trapped by breaker opening and to limit recovery voltages to a level tolerable by the commutating circuit components.
Commutation circuit for an HVDC circuit breaker
Premerlani, W.J.
1981-11-10
A commutation circuit for a high voltage DC circuit breaker incorporates a resistor capacitor combination and a charging circuit connected to the main breaker, such that a commutating capacitor is discharged in opposition to the load current to force the current in an arc after breaker opening to zero to facilitate arc interruption. In a particular embodiment, a normally open commutating circuit is connected across the contacts of a main DC circuit breaker to absorb the inductive system energy trapped by breaker opening and to limit recovery voltages to a level tolerable by the commutating circuit components. 13 figs.
Polymer solar cells with enhanced open-circuit voltage and efficiency
NASA Astrophysics Data System (ADS)
Chen, Hsiang-Yu; Hou, Jianhui; Zhang, Shaoqing; Liang, Yongye; Yang, Guanwen; Yang, Yang; Yu, Luping; Wu, Yue; Li, Gang
2009-11-01
Following the development of the bulk heterojunction structure, recent years have seen a dramatic improvement in the efficiency of polymer solar cells. Maximizing the open-circuit voltage in a low-bandgap polymer is one of the critical factors towards enabling high-efficiency solar cells. Study of the relation between open-circuit voltage and the energy levels of the donor/acceptor in bulk heterojunction polymer solar cells has stimulated interest in modifying the open-circuit voltage by tuning the energy levels of polymers. Here, we show that the open-circuit voltage of polymer solar cells constructed based on the structure of a low-bandgap polymer, PBDTTT, can be tuned, step by step, using different functional groups, to achieve values as high as 0.76 V. This increased open-circuit voltage combined with a high short-circuit current density results in a polymer solar cell with a power conversion efficiency as high as 6.77%, as certified by the National Renewable Energy Laboratory.
Adaptive sequential controller
El-Sharkawi, Mohamed A.; Xing, Jian; Butler, Nicholas G.; Rodriguez, Alonso
1994-01-01
An adaptive sequential controller (50/50') for controlling a circuit breaker (52) or other switching device to substantially eliminate transients on a distribution line caused by closing and opening the circuit breaker. The device adaptively compensates for changes in the response time of the circuit breaker due to aging and environmental effects. A potential transformer (70) provides a reference signal corresponding to the zero crossing of the voltage waveform, and a phase shift comparator circuit (96) compares the reference signal to the time at which any transient was produced when the circuit breaker closed, producing a signal indicative of the adaptive adjustment that should be made. Similarly, in controlling the opening of the circuit breaker, a current transformer (88) provides a reference signal that is compared against the time at which any transient is detected when the circuit breaker last opened. An adaptive adjustment circuit (102) produces a compensation time that is appropriately modified to account for changes in the circuit breaker response, including the effect of ambient conditions and aging. When next opened or closed, the circuit breaker is activated at an appropriately compensated time, so that it closes when the voltage crosses zero and opens when the current crosses zero, minimizing any transients on the distribution line. Phase angle can be used to control the opening of the circuit breaker relative to the reference signal provided by the potential transformer.
NASA Technical Reports Server (NTRS)
Nagano, S.
1979-01-01
Base driver with common-load-current feedback protects paralleled inverter systems from open or short circuits. Circuit eliminates total system oscillation that can occur in conventional inverters because of open circuit in primary transformer winding. Common feedback signal produced by functioning modules forces operating frequency of failed module to coincide with clock drive so module resumes normal operating frequency in spite of open circuit.
Multijunction high voltage concentrator solar cells
NASA Technical Reports Server (NTRS)
Valco, G. J.; Kapoor, V. J.; Evans, J. C.; Chai, A.-T.
1981-01-01
The standard integrated circuit technology has been developed to design and fabricate new innovative planar multi-junction solar cell chips for concentrated sunlight applications. This 1 cm x 1 cm cell consisted of several voltage generating regions called unit cells which were internally connected in series within a single chip resulting in high open circuit voltages. Typical open-circuit voltages of 3.6 V and short-circuit currents of 90 ma were obtained at 80 AM1 suns. A dramatic increase in both short circuit current and open circuit voltage with increased light levels was observed.
Yang, Yonggang; Sun, Guoping; Guo, Jun; Xu, Meiying
2011-07-01
Biofilms formation capacities of Shewanella species in microbial fuel cells (MFCs) and their roles in current generation have been documented to be species-dependent. Understandings of the biofilms growth and metabolism are essential to optimize the current generation of MFCs. Shewanella decolorationis S12 was used in both closed-circuit and open-circuit MFCs in this study. The anodic S. decolorationis S12 biofilms could generate fivefold more current than the planktonic cells, playing a dominant role in current generation. Anodic biofilms viability was sustained at 98 ± 1.2% in closed-circuit while biofilms viability in open-circuit decreased to 72 ± 7% within 96 h. The unviable domain in open-circuit MFCs biofilms majorly located at the inner layer of biofilm. The decreased biofilms viability in open-circuit MFCs could be recovered by switching into closed-circuit, indicating that the current-generating anode in MFCs could serve as a favorable electron acceptor and provide sufficient energy to support cell growth and metabolism inside biofilms. Copyright © 2011 Elsevier Ltd. All rights reserved.
Occupational Survey Report, AFSC 4H0X1 Cardiopulmonary Laboratory
2004-02-01
Health Care Systems (CHCS) 63 Devices, Oxygen (O2) Humidification (Bubble) 63 Electrocardiographic Machines 63 Incentive Spirometer 63 Devices...3.63 63 67 2.91 8 E0180 Maintain open airways 6.74 56 60 5.36 18 E0183 Perform bedside spirometry 5.16 31 33 4.54 12 * Mean TE Rating is 3.18
Casier, Annabelle; Goubert, Liesbet; Vervoort, Tine; Theunis, Marleen; Huse, Danielle; De Baets, Frans; Matthys, Dirk; Crombez, Geert
2013-01-01
OBJECTIVE: To investigate the occurrence of spirometry-related pain and distress in adolescents and young adults with cystic fibrosis (CF), and to investigate the role of acceptance of illness in spirometry-related pain and distress. METHODS: A total of 36 adolescents and young adults with CF (12 to 22 years of age) completed a questionnaire assessing acceptance of illness. Spirometry-related distress was assessed using self-report (ie, anxiety/worry about the procedure) and physiological outcomes (ie, heart rate and heart rate variability) before spirometry. Spirometry-related pain was assessed using self-report (ie, expected pain and pain-related thoughts). Self-reported distress and pain during spirometry were also assessed. RESULTS: Eighty-nine per cent of subjects reported distress before spirometry, 67% experienced distress during spirometry, 28% expected pain during spirometry and 22% actually experienced pain. Interestingly, partial correlations revealed that more acceptance was related to less expected pain and pain-related thoughts. Acceptance, however, was unrelated to distress, anxiety and pain during spirometry. DISCUSSION: The present study suggests that a non-negligible number of adolescents and young adults with CF experience pain and distress during spirometry. Furthermore, results indicate that acceptance may play a protective role in the more indirect consequences of CF such as expected pain and pain-related thoughts during medical procedures. Acceptance, however, was not related to distress before and during spirometry, nor to experienced pain. These findings contribute to the increasing evidence that acceptance may play a protective role in managing the consequences of living with CF. PMID:23985580
Sokol, Kristin C; Sharma, Gulshan; Lin, Yu-Li; Goldblum, Randall M
2015-05-01
The National Asthma Education and Prevention Program (NAEPP) and the American Thoracic Society provide guidelines stating that physicians should use spirometry in the diagnosis and management of asthma. The aim of this study was to evaluate the trends, over a 10-year period, in the utilization of spirometry in patients newly diagnosed with asthma. We hypothesized that spirometry use would increase in physicians who care for asthma patients, especially since 2007, when the revised NAEPP guidelines were published. This retrospective cohort analysis of spirometry use in subjects newly diagnosed with asthma used a privately insured adult population for the years 2002-2011. Our primary outcome of interest was spirometry performed within a year (± 365 days) of the initial date of asthma diagnosis. We also examined the type of asthma medications prescribed. In all, 134,208 patients were found to have a diagnosis of asthma. Only 47.6% had spirometry performed within 1 year of diagnosis. Younger patients, males, and those residing in the Northeast were more likely to receive spirometry. Spirometry use began to decline in 2007. Patients cared for by specialists were more likely to receive spirometry than those cared for by primary care physicians; 80.1% vs 23.3%, respectively. Lastly, even without spirometry, a significant portion of patients (78.3%) was prescribed asthma drugs. Our study suggests that spirometry is underutilized in newly diagnosed asthma patients. Moreover, the use of controller medications in those diagnosed with asthma without spirometry remains high. Copyright © 2015 Elsevier Inc. All rights reserved.
Keyser, R E; Rodgers, M M; Gardner, E R; Russell, P J
1999-10-01
To determine if a single-stage, submaximal fatigue test on a wheelchair ergometer would result in higher than expected energy expenditure. An experimental survey design contrasting physiologic responses during peak graded exercise tests and fatigue tests. A rehabilitation science laboratory that included a prototypical wheelchair ergometer, open-circuit spirometry system, and heart rate monitor. Nine able-bodied non-wheelchair users (the NWC group: 6 men and 3 women, mean +/- SD age 30 +/- 7yrs) and 15 manual wheelchair users (the WC group: 12 men and 3 women, age 40 +/- 9yrs, time in wheelchair 16 +/- 9yrs). No subject had any disease, medication regimen, or upper body neurologic, orthopedic, or other condition that would limit wheelchair exercise. Peak oxygen uptake (VO2) for graded exercise testing and during fatigue testing, using a power output corresponding to 75% peak aerobic capacity on graded exercise test. In the WC group, VO2 at 6 minutes of fatigue testing was not significantly different from peak VO2. In the NWC group, VO2 was similar to the expected level throughout fatigue testing. Energy expenditure was higher than expected in the WC group but not in the NWC group. Fatigue testing may provide a useful evaluation of cardiorespiratory status in manual wheelchair users.
Larrosa-Guerrero, Amor; Scott, Keith; Katuri, Krishna P; Godinez, Carlos; Head, Ian M; Curtis, Thomas
2010-08-01
The influence of various carbon anodes; graphite, sponge, paper, cloth, felt, fiber, foam and reticulated vitreous carbon (RVC); on microbial fuel cell (MFC) performance is reported. The feed was brewery wastewater diluted in domestic wastewater. Biofilms were grown at open circuit or under an external load. Microbial diversity was analysed as a function of current and anode material. The bacterial community formed at open circuit was influenced by the anode material. However at closed circuit its role in determining the bacterial consortia formed was less important than the passage of current. The rate and extent of organic matter removal were similar for all materials: over 95% under closed circuit. The biofilm in MFCs working at open circuit and in the control reactors, increased COD removal by up to a factor of nine compared with that for baseline reactors. The average voltage output was 0.6 V at closed circuit, with an external resistor of 300 kOmega and 0.75 V at open circuit for all materials except RVC. The poor performance of this material might be related to the surface area available and concentration polarizations caused by the morphology of the material and the structure of the biofilm. Peak power varied from 1.3 mW m(-2) for RVC to 568 mW m(-2) for graphite with biofilm grown at closed circuit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... closed-circuit apparatus; maximum allowable limits. 84.97 Section 84.97 Public Health PUBLIC HEALTH... ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.97 Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable limits. (a) Open...
Code of Federal Regulations, 2011 CFR
2011-10-01
... closed-circuit apparatus; maximum allowable limits. 84.97 Section 84.97 Public Health PUBLIC HEALTH... ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.97 Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable limits. (a) Open...
Adeniyi, A F; Saminu, K S
2011-09-01
Efforts to promote better health of sickle cell anaemia (SCA) patients in low-income countries through the use of cheap and available alternatives are desirable. We investigated whether a locally designed incentive spirometry will improve peak expiratory flow rate (PEFR) of teenage SCA patients. Forty-nine SCA teenagers were randomized into either the SCA spirometry or the SCA control groups, which had 24 and 25 patients respectively. They were initially compared with 25 matched non-SCA teenagers. The SCA spirometry group went through a six-week, thrice-daily local incentive spirometry while the control did not go through the exercise. The PEFR of the SCA spirometry group improved significantly (p = 0.001) between the third and sixth week (211.04 ± 55.67 to 292.08 ± 40.86 litres/min) unlike that of the SCA control group (p = 0.605). At six weeks, PEFR of the SCA spirometry group improved significantly (t=0.624, p=0.003) over that of the SCA control group. However, the improved PEFR of the SCA spirometry group did not match that of their non-SCA counterparts. Locally designed incentive spirometry improved PEFR of the SCA teenagers significantly in six weeks of spirometry exercise. Routine improvement in PEFR of SCA patients with the aid of incentive spirometry should be encouraged to improve lung function.
Spirometry for Asthma - When You Need It and Why
... Adult , Geriatric , Pediatric Spirometry for Asthma Spirometry for Asthma When you need the test—and why DOWNLOAD ... you should have a spirometry test. Here’s why: Asthma and other diseases can have the same symptoms. ...
Irizar-Aramburu, María Isabel; Martínez-Eizaguirre, Jose Manuel; Pacheco-Bravo, Petra; Diaz-Atienza, Maria; Aguirre-Arratibel, Iñigo; Peña-Peña, Maria Isabel; Alba-Latorre, Mercedes; Galparsoro-Goikoetxea, Mikel
2013-12-05
Smoking is the main preventable cause of morbidity and mortality in our region, it being the main causative agent of chronic obstructive pulmonary disease. There still is no consensus on the use of spirometry as a strategy for smoking cessation, given that there is insufficient scientific evidence from high quality studies to recommend the use of this technique. This is to be a randomized, multicentre, open-label clinical trial. A total of 444 smokers over 40 years of age will be recruited by 39 general practitioners from 22 health centers. Primary objective of this study is to assess the effectiveness of spirometry together with information regarding the test for smoking cessation after 1 year in smokers over 40 years of age with a more than 10 pack-year history and no previous diagnosis of chronic obstructive pulmonary disease. Groups of 45 patients who smoke will be randomly selected from the lists of the participating doctors. The names will be sent to the corresponding doctors who will contact candidate patients and assess whether they meet the selection criteria. Patients who meet these criteria will be randomly allocated to an intervention or control group. For patients in both groups, a nurse will conduct an interview and perform a spirometry test to measure forced vital capacity. Then, all patients will be referred for an appointment with their doctor for brief anti-smoking intervention, patients from the intervention group additionally being informed about the result of the spirometry test. After 1 year, smoking status will be assessed and, in those who report that they have quit smoking, abstinence will be confirmed by co-oximetry. Data will be analyzed on an intention-to-treat basis using the chi-squared test for outcomes and binary logistic regression if it is considered to be necessary to adjust for confounding variables. Performing a spirometry test and providing information on pulmonary function may increase awareness of the effect of smoking among smokers who are asymptomatic or have few symptoms and make them decide to quit. Specifically, in patients with chronic obstructive pulmonary disease it might increase levels of motivation to quit smoking in early stages of the disease. If this strategy were to be effective, it could be included in the health promotion activities offered in primary care. ClinicalTrials.gov Identifier: NCT01821885.
Massaroni, Carlo; Cassetta, Eugenio; Silvestri, Sergio
2017-10-01
Respiratory assessment can be carried out by using motion capture systems. A geometrical model is mandatory in order to compute the breathing volume as a function of time from the markers' trajectories. This study describes a novel model to compute volume changes and calculate respiratory parameters by using a motion capture system. The novel method, ie, prism-based method, computes the volume enclosed within the chest by defining 82 prisms from the 89 markers attached to the subject chest. Volumes computed with this method are compared to spirometry volumes and to volumes computed by a conventional method based on the tetrahedron's decomposition of the chest wall and integrated in a commercial motion capture system. Eight healthy volunteers were enrolled and 30 seconds of quiet breathing data collected from each of them. Results show a better agreement between volumes computed by the prism-based method and the spirometry (discrepancy of 2.23%, R 2 = .94) compared to the agreement between volumes computed by the conventional method and the spirometry (discrepancy of 3.56%, R 2 = .92). The proposed method also showed better performances in the calculation of respiratory parameters. Our findings open up prospects for the further use of the new method in the breathing assessment via motion capture systems.
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2013 CFR
2013-10-01
... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2013-10-01 2013-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2012 CFR
2012-10-01
... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2012-10-01 2012-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...
42 CFR 84.95 - Service time test; open-circuit apparatus.
Code of Federal Regulations, 2014 CFR
2014-10-01
... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2014-10-01 2014-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...
Xu, Shi-Zhou; Wang, Chun-Jie; Lin, Fang-Li; Li, Shi-Xiang
2017-10-31
The multi-device open-circuit fault is a common fault of ANPC (Active Neutral-Point Clamped) three-level inverter and effect the operation stability of the whole system. To improve the operation stability, this paper summarized the main solutions currently firstly and analyzed all the possible states of multi-device open-circuit fault. Secondly, an order-reduction optimal control strategy was proposed under multi-device open-circuit fault to realize fault-tolerant control based on the topology and control requirement of ANPC three-level inverter and operation stability. This control strategy can solve the faults with different operation states, and can works in order-reduction state under specific open-circuit faults with specific combined devices, which sacrifices the control quality to obtain the stability priority control. Finally, the simulation and experiment proved the effectiveness of the proposed strategy.
Molecular interfaces for plasmonic hot electron photovoltaics
NASA Astrophysics Data System (ADS)
Pelayo García de Arquer, F.; Mihi, Agustín; Konstantatos, Gerasimos
2015-01-01
The use of self-assembled monolayers (SAMs) to improve and tailor the photovoltaic performance of plasmonic hot-electron Schottky solar cells is presented. SAMs allow the simultaneous control of open-circuit voltage, hot-electron injection and short-circuit current. To that end, a plurality of molecule structural parameters can be adjusted: SAM molecule's length can be adjusted to control plasmonic hot electron injection. Modifying SAMs dipole moment allows for a precise tuning of the open-circuit voltage. The functionalization of the SAM can also be selected to modify short-circuit current. This allows the simultaneous achievement of high open-circuit voltages (0.56 V) and fill-factors (0.58), IPCE above 5% at the plasmon resonance and maximum power-conversion efficiencies of 0.11%, record for this class of devices.The use of self-assembled monolayers (SAMs) to improve and tailor the photovoltaic performance of plasmonic hot-electron Schottky solar cells is presented. SAMs allow the simultaneous control of open-circuit voltage, hot-electron injection and short-circuit current. To that end, a plurality of molecule structural parameters can be adjusted: SAM molecule's length can be adjusted to control plasmonic hot electron injection. Modifying SAMs dipole moment allows for a precise tuning of the open-circuit voltage. The functionalization of the SAM can also be selected to modify short-circuit current. This allows the simultaneous achievement of high open-circuit voltages (0.56 V) and fill-factors (0.58), IPCE above 5% at the plasmon resonance and maximum power-conversion efficiencies of 0.11%, record for this class of devices. Electronic supplementary information (ESI) available: Contact-potential differentiometry measurements, FTIR characterization, performance statistics and gold devices. See DOI: 10.1039/c4nr06356b
Strong, Mark; South, Gail; Carlisle, Robin
2009-01-01
Background Accurate spirometry is important in the management of COPD. The UK Quality and Outcomes Framework pay-for-performance scheme for general practitioners includes spirometry related indicators within its COPD domain. It is not known whether high achievement against QOF spirometry indicators is associated with spirometry to BTS standards. Methods Data were obtained from the records of 3,217 patients randomly sampled from 5,649 patients with COPD in 38 general practices in Rotherham, UK. Severity of airflow obstruction was categorised by FEV1 (% predicted) according to NICE guidelines. This was compared with clinician recorded COPD severity. The proportion of patients whose spirometry met BTS standards was calculated in each practice using a random sub-sample of 761 patients. The Spearman rank correlation between practice level QOF spirometry achievement and performance against BTS spirometry standards was calculated. Results Spirometry as assessed by clinical records was to BTS standards in 31% of cases (range at practice level 0% to 74%). The categorisation of airflow obstruction according to the most recent spirometry results did not agree well with the clinical categorisation of COPD recorded in the notes (Cohen's kappa = 0.34, 0.30 – 0.38). 12% of patients on COPD registers had FEV1 (% predicted) results recorded that did not support the diagnosis of COPD. There was no association between quality, as measured by adherence to BTS spirometry standards, and either QOF COPD9 achievement (Spearman's rho = -0.11), or QOF COPD10 achievement (rho = 0.01). Conclusion The UK Quality and Outcomes Framework currently assesses the quantity, but not the quality of spirometry. PMID:19558719
Strong, Mark; South, Gail; Carlisle, Robin
2009-06-28
Accurate spirometry is important in the management of COPD. The UK Quality and Outcomes Framework pay-for-performance scheme for general practitioners includes spirometry related indicators within its COPD domain. It is not known whether high achievement against QOF spirometry indicators is associated with spirometry to BTS standards. Data were obtained from the records of 3,217 patients randomly sampled from 5,649 patients with COPD in 38 general practices in Rotherham, UK. Severity of airflow obstruction was categorised by FEV1 (% predicted) according to NICE guidelines. This was compared with clinician recorded COPD severity. The proportion of patients whose spirometry met BTS standards was calculated in each practice using a random sub-sample of 761 patients. The Spearman rank correlation between practice level QOF spirometry achievement and performance against BTS spirometry standards was calculated. Spirometry as assessed by clinical records was to BTS standards in 31% of cases (range at practice level 0% to 74%). The categorisation of airflow obstruction according to the most recent spirometry results did not agree well with the clinical categorisation of COPD recorded in the notes (Cohen's kappa = 0.34, 0.30 - 0.38). 12% of patients on COPD registers had FEV1 (% predicted) results recorded that did not support the diagnosis of COPD. There was no association between quality, as measured by adherence to BTS spirometry standards, and either QOF COPD9 achievement (Spearman's rho = -0.11), or QOF COPD10 achievement (rho = 0.01). The UK Quality and Outcomes Framework currently assesses the quantity, but not the quality of spirometry.
Spirometry Use among Older Adults with Chronic Obstructive Pulmonary Disease: 1999–2008
Wang, Yue; Kuo, Yong-Fang; Goodwin, James S.; Sharma, Gulshan
2013-01-01
Rationale: Clinical practice guidelines recommend spirometry to diagnose chronic obstructive pulmonary disease (COPD) and facilitate management. National trends in spirometry use in older adults with newly diagnosed COPD are not known. Objectives: To examine the rate and beneficiary characteristics associated with spirometry use in subjects with newly diagnosed COPD between 1999 and 2008. Methods: We examined newly diagnosed beneficiaries with COPD using a 5% Medicare population from 1999 to 2008. A new COPD diagnosis required two outpatient visits or one hospitalization with primary International Classification of Diseases, 9th edition code 491.xx, 492.xx, or 496 occurring at least 30 days apart with none in the prior 12 months. The primary measurement was spirometry performed within 365 days (±) of the first claim with a COPD diagnosis. Measurements and Main Results: Between 1999 and 2008, 64,985 subjects were newly diagnosed with COPD. Of these, 35,739 (55%) had spirometry performed within 1 year before or after the initial diagnosis of COPD. Spirometry use increased from 51.3% in 1999 to 58.3% in 2008 (P < 0.001). Subjects with younger age, men, whites, those with higher socioeconomic status, and those with a greater number of comorbidities were more likely to have spirometry. In a multivariable analysis, compared with 1999, subjects diagnosed in 2008 had 10% higher odds (odds ratio, 1.10; 95% confidence interval, 1.06–1.13) of having spirometry performed. Conclusions: Despite an increase in the use of spirometry over time in newly diagnosed older adults with COPD, spirometry use remains low. Clinical practice guidelines and educational efforts should focus on increasing the use of spirometry to diagnose and manage COPD. PMID:24053440
Morgenroth, S; Thomas, J; Cannizzaro, V; Weiss, M; Schmidt, A R
2018-03-01
Spirometric monitoring provides precise measurement and delivery of tidal volumes within a narrow range, which is essential for lung-protective strategies that aim to reduce morbidity and mortality in mechanically-ventilated patients. Conventional anaesthesia ventilators include inbuilt spirometry to monitor inspiratory and expiratory tidal volumes. The GE Aisys CS 2 anaesthesia ventilator allows additional near-patient spirometry via a sensor interposed between the proximal end of the tracheal tube and the respiratory tubing. Near-patient and inbuilt spirometry of two different GE Aisys CS 2 anaesthesia ventilators were compared in an in-vitro study. Assessments were made of accuracy and variability in inspiratory and expiratory tidal volume measurements during ventilation of six simulated paediatric lung models using the ASL 5000 test lung. A total of 9240 breaths were recorded and analysed. Differences between inspiratory tidal volumes measured with near-patient and inbuilt spirometry were most significant in the newborn setting (p < 0.001), and became less significant with increasing age and weight. During expiration, tidal volume measurements with near-patient spirometry were consistently more accurate than with inbuilt spirometry for all lung models (p < 0.001). Overall, the variability in measured tidal volumes decreased with increasing tidal volumes, and was smaller with near-patient than with inbuilt spirometry. The variability in measured tidal volumes was higher during expiration, especially with inbuilt spirometry. In conclusion, the present in-vitro study shows that measurements with near-patient spirometry are more accurate and less variable than with inbuilt spirometry. Differences between measurement methods were most significant in the smallest patients. We therefore recommend near-patient spirometry, especially for neonatal and paediatric patients. © 2018 The Association of Anaesthetists of Great Britain and Ireland.
Koefoed, Mette M; Søndergaard, Jens; Christensen, René dePont; Jarbøl, Dorte E
2013-06-14
Socioeconomic status is known to influence the prevalence, severity and mortality of obstructive lung diseases, but it is uncertain whether it affects the use of diagnostic spirometry in patients initiating treatment for these conditions. The objective of this paper was to examine a possible association between education, income, labour market affiliation, cohabitation status and having spirometry performed when initiating medication targeting obstructive pulmonary disease. We conducted a population-based cohort study. Danish national registers were linked, retrieving data on prescriptions, spirometry testing, socioeconomic and demographic variables in all first time users of medication targeting obstructive lung disease in 2008. A total of 37,734 persons were included and approximately half of the cohort had spirometry performed. Among medication users under 65 years of age, being unemployed was significantly associated with reduced odds of having spirometry performed, the strongest association was seen in men (OR = 0.82, CI = 0.73-0.91). Medium income was associated with increased odds of having spirometry performed in men (OR =1.18, CI = 1.06-1.30) and high educational level (>12 years) was associated with reduced odds of having spirometry performed in women (OR = 0.86, CI = 0.78-0.94). Cohabitation status was not associated with having spirometry performed. Among medication users over 65 years of age, living alone was associated with reduced odds of having spirometry performed among men (OR = 0.78, CI = 0.69-0.88). Social inequity in spirometry testing among patients initiating medication targeting obstructive lung disease was confirmed in this study. Increased focus on spirometry testing among elderly men living alone, among the unemployed and among women with higher education is required when initiating medication.
42 CFR 37.96 - Spirometry interpretations, reports, and notifications.
Code of Federal Regulations, 2014 CFR
2014-10-01
... system used, render permanently inaccessible all files and forms associated with a miner's spirometry... spirometry examination shows abnormal results or if the respiratory assessment suggests he or she may benefit... specified under a facility's approval, it must submit spirometry results and the completed Respiratory...
42 CFR 37.95 - Specifications for performing spirometry examinations.
Code of Federal Regulations, 2014 CFR
2014-10-01
... examinations must include the following: (1) Pre-test checklist. A short Spirometry Pre-Test Checklist (Form... spirometry examinations electronically with content as specified in § 37.96(b), pre-test screening checklists... spirometry examinations, pre-test checklists, and standardized respiratory assessment results in electronic...
Gupta, Samir; Moosa, Dilshad; MacPherson, Ana; Allen, Christopher; Tamari, Itamar E
2016-04-21
Asthma is among the most common chronic diseases in adults. International guidelines have emphasized the importance of regular spirometry for asthma control evaluation. However, spirometry use in primary care remains low across jurisdictions. We sought to design and evaluate a knowledge translation intervention to address both the poor quality of spirometry and the underuse of spirometry in primary care. We designed a 1-year intervention consisting of initial interactive education and hands-on training followed by unstructured peer expert mentoring (through an online portal, email, telephone, videoconference, fax, and/or in-person). We recruited physician and allied health mentees from across primary care sites in Ontario, Canada. We compared spirometry-related knowledge immediately before and after the 1-year intervention period and the quality of spirometry testing and the usage of spirometry in patients with asthma in the year before and the year of the intervention. Seven of 10 (70 %) invited sites participated, including 25/90 (28 %) invited allied health mentees and 23/68 (34 %) invited physician mentees. We recruited 7 physician mentors and 4 allied health mentors to form 3 mentor-mentee pods. Spirometry knowledge scores increased from 21.4 +/- 3.1 pre- to 27.3 +/- 3.5 (out of 35) (p < 0.01) post-intervention. Spirometry acceptability and repeatability criteria were met by 59/191 (30.9 %) spirometries and 86/193 (44.6 %) spirometries [odds ratio 1.7 (1.0, 3.0)], in the pre-intervention and intervention periods, respectively. Spirometry was ordered in 75/512 (14.6 %) and 129/336 (38.4 %) respiratory visits (p < 0.01), and in 20/3490 (0.6 %) and 36/2649 (1.4 %) non-respiratory visits (p < 0.01), in the pre-intervention and intervention periods, respectively. A mentorship-based intervention involving physicians and allied health team members can enhance knowledge, quality, and actual use of spirometry in real world primary care settings. A future controlled study should assess the impact of this intervention on patient outcomes, its cost-effectiveness, and its sustainability.
Teguh, Jefri S; Kurniawan, Michael; Wu, Xiangyang; Sum, Tze Chien; Yeow, Edwin K L
2013-01-07
Fluorescence intensity modulation of single Atto647N dye molecules in a short-circuit device and a defective device, caused by damaging an open-circuit device, is due to a variation in the excitation light focus as a result of the formation of an alternating electric current.
2014-01-01
Background We recently demonstrated that quality of spirometry in primary care could markedly improve with remote offline support from specialized professionals. It is hypothesized that implementation of automatic online assessment of quality of spirometry using information and communication technologies may significantly enhance the potential for extensive deployment of a high quality spirometry program in integrated care settings. Objective The objective of the study was to elaborate and validate a Clinical Decision Support System (CDSS) for automatic online quality assessment of spirometry. Methods The CDSS was done through a three step process including: (1) identification of optimal sampling frequency; (2) iterations to build-up an initial version using the 24 standard spirometry curves recommended by the American Thoracic Society; and (3) iterations to refine the CDSS using 270 curves from 90 patients. In each of these steps the results were checked against one expert. Finally, 778 spirometry curves from 291 patients were analyzed for validation purposes. Results The CDSS generated appropriate online classification and certification in 685/778 (88.1%) of spirometry testing, with 96% sensitivity and 95% specificity. Conclusions Consequently, only 93/778 (11.9%) of spirometry testing required offline remote classification by an expert, indicating a potential positive role of the CDSS in the deployment of a high quality spirometry program in an integrated care setting. PMID:25600957
Sengpiel, Juliane; Fuehner, Thomas; Kugler, Christiane; Avsar, Murat; Bodmann, Isabelle; Boemke, Annelies; Simon, Andre; Welte, Tobias; Gottlieb, Jens
2010-12-01
Complications often occur during the early phase after lung transplantation, and rapid diagnosis is vital. Home spirometry is used to detect early changes in graft function. Bluetooth-equipped cell phones are easy to use and facilitate data transfer from home spirometry. To explore use of home spirometry with Bluetooth data transfer in outpatient lung transplant recipients. Single-center prospective randomized controlled trial. Intervention-Fifty-six patients were randomized either to home spirometry with data transfer via Bluetooth-equipped cell phones or to home spirometry alone before discharge after lung transplantation. In the Bluetooth group, results were transferred to a database capable of generating alarm messages. Time from onset of symptoms to physician consultation during the first 6 months after lung transplantation was the primary end point. Adherence to home spirometry was 97.2% in the Bluetooth group and 95.3% in the home spirometry alone group (P = .73). Median time to first consultation (P = .60) and frequency of consultation (P = .06) did not differ significantly in the 2 groups. Mean scores on the Hospital Anxiety and Depression Scale were lower in patients in the Bluetooth group (1.5; range, 0.0-4.0) than in the home spirometry alone group (4.0; range, 2.0-6.0; P = .04). Home spirometry with data transfer is feasible and safe in lung transplant recipients. Compared with home spirometry alone, additional data transfer was equally effective regarding the time interval from symptom onset to consultation. Patients in the Bluetooth group reported less anxiety, which may improve emotional well-being.
DISTRIBUTED RC NETWORKS WITH RATIONAL TRANSFER FUNCTIONS,
A distributed RC circuit analogous to a continuously tapped transmission line can be made to have a rational short-circuit transfer admittance and...one rational shortcircuit driving-point admittance. A subcircuit of the same structure has a rational open circuit transfer impedance and one rational ...open circuit driving-point impedance. Hence, rational transfer functions may be obtained while considering either generator impedance or load
On the SCTC-OCTC Method for the Analysis and Design of Circuits
ERIC Educational Resources Information Center
Salvatori, S.; Conte, G.
2009-01-01
This paper discusses guidelines that emphasize the relevance of short-circuit- and open-circuit-time constant (SCTC and OCTC, respectively) methods in the analysis and design of electronic amplifiers. It is demonstrated that it is only necessary to grasp a few concepts in order to understand that the two short- and open-circuit cases fall into a…
Noncontact spirometry with a webcam
NASA Astrophysics Data System (ADS)
Liu, Chenbin; Yang, Yuting; Tsow, Francis; Shao, Dangdang; Tao, Nongjian
2017-05-01
We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vital capacity, and peak expiratory flow rate. We validate the accuracy of the method by comparing the data with those simultaneously recorded with a gold standard reference method and examine the reliability of the noncontact spirometry with a pilot study including 16 subjects. This work demonstrates that the noncontact method can provide accurate and reliable spirometry tests with a webcam. Compared to the traditional spirometers, the present noncontact spirometry does not require using a spirometer, breathing into a mouthpiece, or wearing a nose clip, thus making spirometry test more easily accessible for the growing population of asthma and chronic obstructive pulmonary diseases.
Noncontact spirometry with a webcam.
Liu, Chenbin; Yang, Yuting; Tsow, Francis; Shao, Dangdang; Tao, Nongjian
2017-05-01
We present an imaging-based method for noncontact spirometry. The method tracks the subtle respiratory-induced shoulder movement of a subject, builds a calibration curve, and determines the flow-volume spirometry curve and vital respiratory parameters, including forced expiratory volume in the first second, forced vital capacity, and peak expiratory flow rate. We validate the accuracy of the method by comparing the data with those simultaneously recorded with a gold standard reference method and examine the reliability of the noncontact spirometry with a pilot study including 16 subjects. This work demonstrates that the noncontact method can provide accurate and reliable spirometry tests with a webcam. Compared to the traditional spirometers, the present noncontact spirometry does not require using a spirometer, breathing into a mouthpiece, or wearing a nose clip, thus making spirometry test more easily accessible for the growing population of asthma and chronic obstructive pulmonary diseases.
Restrepo, Ruben D; Wettstein, Richard; Wittnebel, Leo; Tracy, Michael
2011-10-01
We searched the MEDLINE, CINAHL, and Cochrane Library databases for articles published between January 1995 and April 2011. The update of this clinical practice guideline is the result of reviewing a total of 54 clinical trials and systematic reviews on incentive spirometry. The following recommendations are made following the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) scoring system. 1: Incentive spirometry alone is not recommended for routine use in the preoperative and postoperative setting to prevent postoperative pulmonary complications. 2: It is recommended that incentive spirometry be used with deep breathing techniques, directed coughing, early mobilization, and optimal analgesia to prevent postoperative pulmonary complications. 3: It is suggested that deep breathing exercises provide the same benefit as incentive spirometry in the preoperative and postoperative setting to prevent postoperative pulmonary complications. 4: Routine use of incentive spirometry to prevent atelectasis in patients after upper-abdominal surgery is not recommended. 5: Routine use of incentive spirometry to prevent atelectasis after coronary artery bypass graft surgery is not recommended. 6: It is suggested that a volume-oriented device be selected as an incentive spirometry device.
Quality and learning aspects of the first 9000 spirometries of the LifeGene study.
Qvarfordt, Mikaela; Anderson, Martin; Svartengren, Magnus
2018-02-19
Spirometry requires the patient to cooperate and do the manoeuvre 'right' for reliable results. Algorithms to assess test quality as well as educational recommendations for personnel are defined in guidelines. We compared the quality of forced spirometry tests performed by spirometry technicians with little or no previous experience of spirometry using spirometry systems with different modes of feedback. In both cases, the spirometry technician received general feedback on the screen based on ATS/ERS guidelines, such as 'exhale faster' and 'exhale longer'. The major difference was whether quality grading system of the complete session was available simultaneously on screen, or in the printed report afterwards. Two parts of the same population-based study (LifeGene), the pilot (LG1) and the first part (LG2) of the subsequent study, were compared retrospectively. In LG1 (on-screen grading) approved examination quality was achieved for 88% of the 10 first subjects for each spirometry technician compared to 70% in LG2 (printed grading afterwards). The corresponding values after 40 subjects was 94 % in LG1, compared to 73% in LG2, and after the first ten subjects there was no apparent quality improvement in either LG1 or LG2. The quality for LG1 is among the highest reported in the literature even though the spirometry technician were relatively inexperienced. We conclude that on-screen grading in addition to general technical quality feedback is powerful in enhancing the spirometry test session quality.
Lima, Illia Ndf; Fregonezi, Guilherme Af; Melo, Rodrigo; Cabral, Elis Ea; Aliverti, Andrea; Campos, Tânia F; Ferreira, Gardênia Mh
2014-07-01
The aim of the present study was to assess how volume-oriented incentive spirometry applied to patients after a stroke modifies the total and compartmental chest wall volume variations, including both the right and left hemithoraces, compared with controls. Twenty poststroke patients and 20 age-matched healthy subjects were studied by optoelectronic plethysmography during spontaneous quiet breathing (QB), during incentive spirometry, and during the recovery period after incentive spirometry. Incentive spirometry was associated with an increased chest wall volume measured at the pulmonary rib cage, abdominal rib cage and abdominal compartment (P = .001) and under 3 conditions (P < .001). Compared with healthy control subjects, the tidal volume (VT) of the subjects with stroke was 24.7, 18.0, and 14.7% lower during QB, incentive spirometry, and postincentive spirometry, respectively. Under all 3 conditions, the contribution of the abdominal compartment to VT was greater in the stroke subjects (54.1, 43.2, and 48.9%) than in the control subjects (43.7, 40.8, and 46.1%, P = .039). In the vast majority of subjects (13/20 and 18/20 during QB and incentive spirometry, respectively), abdominal expansion precedes rib cage expansion during inspiration. Greater asymmetry between the right and left hemithoracic expansions occurred in stroke subjects compared with control subjects, but it decreased during QB (62.5%, P = .002), during incentive spirometry (19.7%), and postincentive spirometry (67.6%, P = .14). Incentive spirometry promotes increased expansion in all compartments of the chest wall and reduces asymmetric expansion between the right and left parts of the pulmonary rib cage; therefore, it should be considered as a tool for rehabilitation. Copyright © 2014 by Daedalus Enterprises.
Differences in the use of spirometry between rural and urban primary care centers in Spain.
Márquez-Martín, Eduardo; Soriano, Joan B; Rubio, Myriam Calle; Lopez-Campos, Jose Luis
2015-01-01
The aim of this study is to evaluate the ability and practice of spirometry, training of technicians, and spirometry features in primary care centers in Spain, evaluating those located in a rural environment against those in urban areas. An observational cross-sectional study was conducted in 2012 by a telephone survey in 970 primary health care centers in Spain. The centers were divided into rural or urban depending on the catchment population. The survey contacted technicians in charge of spirometry and consisted of 36 questions related to the test that included the following topics: center resources, training doctors and technicians, using the spirometer, bronchodilator test, and the availability of spirometry and maintenance. Although the sample size was achieved in both settings, rural centers (RCs) gave a lower response rate than urban centers (UCs). The number of centers without spirometry in rural areas doubled those in the urban areas. Most centers had between one and two spirometers. However, the number of spirometry tests per week was significantly lower in RCs than in UCs (4 [4.1%] vs 6.9 [5.7%], P<0.01). The availability of a specific schedule for conducting spirometries was higher in RCs than in UCs (209 [73.0%] vs 207 [64.2%], P=0.003). RCs were more satisfied with the spirometries (7.8 vs 7.6, P=0.019) and received more training course for interpreting spirometry (41.0% vs 33.2%, P=0.004). The performance of the bronchodilator test showed a homogeneous measure in different ways. The spirometer type and the reference values were unknown to the majority of respondents. This study shows the differences between primary care RCs and UCs in Spain in terms of performing spirometry. The findings in the present study can be used to improve the performance of spirometry in these areas.
Differences in the use of spirometry between rural and urban primary care centers in Spain
Márquez-Martín, Eduardo; Soriano, Joan B; Rubio, Myriam Calle; Lopez-Campos, Jose Luis
2015-01-01
Objectives The aim of this study is to evaluate the ability and practice of spirometry, training of technicians, and spirometry features in primary care centers in Spain, evaluating those located in a rural environment against those in urban areas. Methods An observational cross-sectional study was conducted in 2012 by a telephone survey in 970 primary health care centers in Spain. The centers were divided into rural or urban depending on the catchment population. The survey contacted technicians in charge of spirometry and consisted of 36 questions related to the test that included the following topics: center resources, training doctors and technicians, using the spirometer, bronchodilator test, and the availability of spirometry and maintenance. Results Although the sample size was achieved in both settings, rural centers (RCs) gave a lower response rate than urban centers (UCs). The number of centers without spirometry in rural areas doubled those in the urban areas. Most centers had between one and two spirometers. However, the number of spirometry tests per week was significantly lower in RCs than in UCs (4 [4.1%] vs 6.9 [5.7%], P<0.01). The availability of a specific schedule for conducting spirometries was higher in RCs than in UCs (209 [73.0%] vs 207 [64.2%], P=0.003). RCs were more satisfied with the spirometries (7.8 vs 7.6, P=0.019) and received more training course for interpreting spirometry (41.0% vs 33.2%, P=0.004). The performance of the bronchodilator test showed a homogeneous measure in different ways. The spirometer type and the reference values were unknown to the majority of respondents. Conclusion This study shows the differences between primary care RCs and UCs in Spain in terms of performing spirometry. The findings in the present study can be used to improve the performance of spirometry in these areas. PMID:26316737
Gaffin, Jonathan M.; Shotola, Nancy Lichtenberg; Martin, Thomas R.; Phipatanakul, Wanda
2010-01-01
Rationale In 2007 the American Thoracic Society (ATS) recommended guidelines for acceptability and repeatability for assessing spirometry in preschool children. The authors aim to determine the feasibility of spirometry among children in this age group performing spirometry for the first time in a busy clinical practice. Methods First-time spirometry for children age 4 to 5 years old was selected from the Children’s Hospital Boston Pulmonary Function Test (PFT) database. Maneuvers were deemed acceptable if (1) the flow-volume loop showed rapid rise and smooth descent; (2) the back extrapolated volume (Vbe), the volume leaked by a subject prior to the forced maneuver, was ≤80 ml and 12.5% of forced vital capacity (FVC); and (3) cessation of expiratory flow was at a point ≤10% of peak expiratory flow rate (PEFR). Repeatability was determined by another acceptable maneuver with forced expiratory volume in t seconds (FEVt) and FVC within 10% or 0.1 L of the best acceptable maneuver. Post hoc analysis compared spirometry values for those with asthma and cystic fibrosis to normative values. Results Two hundred and forty-eight preschool children performed spirometry for the first time between August 26, 2006, and August 25, 2008. At least one technically acceptable maneuver was found in 82.3% (n = 204) of the tests performed. Overall, 54% of children were able to perform acceptable and repeatable spirometry based on the ATS criteria. Children with asthma or cystic fibrosis did not have spirometry values that differed significantly from healthy controls. However, up to 29% of the overall cohort displayed at least one abnormal spirometry value. Conclusions Many preschool-aged children are able to perform technically acceptable and repeatable spirometry under normal conditions in a busy clinical setting. Spirometry may be a useful screen for abnormal lung function in this age group. PMID:20653495
Impact of a Pharmacist-Provided Spirometry Service on Access to Results in a Primary Care Setting.
Mueller, Lisa A; Valentino, Alexa Sevin; Clark, Aaron D; Li, Junan
2018-01-01
The primary objective of this study was to determine the effect of a pharmacist-provided spirometry service within a federally qualified health center on the percentage of spirometry referrals completed with results reviewed by the ordering provider. Secondary objectives evaluated differences between internal and external referrals, medication recommendations made by the pharmacist, and revenue brought in by the service. Chart reviews were completed to determine the referral completion rates between patients who received a spirometry referral before (December 2014-September 2015) and after (January 2016-October 2016) the implementation of the pharmacy-provided spirometry service. Chart reviews were also used to determine the number and completion rate among referrals for internal and external services in the postimplementation time frame. Chart reviews also assessed medication recommendations made by the pharmacist. The results demonstrate an increase in referral completion rate from 38.1% to 47.0% ( P = .08) between the pre- and postimplementation time frames. In the postimplementation time frame, there was a statistically significant difference in the percentage of referrals completed between in-house referrals and external referrals (70.0% and 40.9%, respectively, P = .0004). Comparing clinics with and without the spirometry service, there was a statistically significant difference in the total number of spirometry referrals (1.13% and 0.59%, respectively, P < .0001) and the percent of referrals completed (0.55% and 0.27%, respectively, P = .0002). The results suggest that offering spirometry within the primary care setting helps to increase the rate of completed spirometry tests with results available to the primary care provider. Additionally, the results show that there is an increased completion rate in patients who receive an internal spirometry referral, which may be due to reduced barriers in obtaining this testing. Overall, these results demonstrate that providing spirometry in the primary care setting helps to increase spirometry results obtained and could be beneficial in other primary care settings.
2013-01-01
Background Smoking is the main preventable cause of morbidity and mortality in our region, it being the main causative agent of chronic obstructive pulmonary disease. There still is no consensus on the use of spirometry as a strategy for smoking cessation, given that there is insufficient scientific evidence from high quality studies to recommend the use of this technique. Methods/Design This is to be a randomized, multicentre, open-label clinical trial. A total of 444 smokers over 40 years of age will be recruited by 39 general practitioners from 22 health centers. Primary objective of this study is to assess the effectiveness of spirometry together with information regarding the test for smoking cessation after 1 year in smokers over 40 years of age with a more than 10 pack-year history and no previous diagnosis of chronic obstructive pulmonary disease. Groups of 45 patients who smoke will be randomly selected from the lists of the participating doctors. The names will be sent to the corresponding doctors who will contact candidate patients and assess whether they meet the selection criteria. Patients who meet these criteria will be randomly allocated to an intervention or control group. For patients in both groups, a nurse will conduct an interview and perform a spirometry test to measure forced vital capacity. Then, all patients will be referred for an appointment with their doctor for brief anti-smoking intervention, patients from the intervention group additionally being informed about the result of the spirometry test. After 1 year, smoking status will be assessed and, in those who report that they have quit smoking, abstinence will be confirmed by co-oximetry. Data will be analyzed on an intention-to-treat basis using the chi-squared test for outcomes and binary logistic regression if it is considered to be necessary to adjust for confounding variables. Discussion Performing a spirometry test and providing information on pulmonary function may increase awareness of the effect of smoking among smokers who are asymptomatic or have few symptoms and make them decide to quit. Specifically, in patients with chronic obstructive pulmonary disease it might increase levels of motivation to quit smoking in early stages of the disease. If this strategy were to be effective, it could be included in the health promotion activities offered in primary care. Trial registration ClinicalTrials.gov Identifier: NCT01821885 PMID:24308728
Survey about the use of lung function testing in public hospitals in Catalonia in 2009.
Roger, Nuria; Burgos, Felip; Giner, Jordi; Rosas, Alba; Tresserras, Ricard; Escarrabill, Joan
2013-09-01
Underdiagnosis is one of the problems with the greatest impact on respiratory disease management and requires specific interventions. Access to quality spirometry is especially important and is an objective of the Master Plan for Respiratory Diseases of the Department of Health of the Generalitat de Catalunya. To determine the current use of spirometry at public hospitals in Catalonia, possible deficiencies and options for improvement. A cross-sectional survey of 65 public hospitals in Catalonia in 2009. Descriptive analyses were developed for each public health-care region. A lack of uniformity was observed in the use of spirometry at the regional level (between 0,98 and 1.50 spirometries per 100 inhabitants). We identified two factors associated with a higher rate of spirometry: i) the existence of a Respiratory Medicine Department at the hospital, and ii) the existence of a set location to carry out spirometries. Several areas for improvement also were identified: quality control of the test itself, the inclusion of spirometry in electronic health-care records and continuing education programs. The results of this study have identified areas for improvement in spirometry programs. Copyright © 2012 SEPAR. Published by Elsevier Espana. All rights reserved.
49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts or...
49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Open-wire transmission line; clearance to other..., AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission line; clearance to other circuits. Open-wire transmission line operating at voltage of 750 volts or...
Huang, Jian; Wang, Zhiwei; Zhu, Chaowei; Ma, Jinxing; Zhang, Xingran; Wu, Zhichao
2014-01-01
Two bioelectrochemical membrane bioreactors (MBRs) developed by integrating microbial fuel cell and MBR technology were operated under closed-circuit and open-circuit modes, and high-throughput 454 pyrosequencing was used to investigate the effects of the power generation on the microbial community of bio-anode and bio-cathode. Microbes on the anode under open-circuit operation (AO) were enriched and highly diverse when compared to those on the anode under closed-circuit operation (AC). However, among the cathodes the closed-circuit mode (CC) had richer and more diverse microbial community compared to the cathode under open-circuit mode (CO). On the anodes AO and AC, Proteobacteria and Bacteroidetes were the dominant phyla, while Firmicutes was enriched only on AC. Deltaproteobacteria affiliated to Proteobacteria were also more abundant on AC than AO. Furthermore, the relative abundance of Desulfuromonas, which are well-known electrogenic bacteria, were much higher on AC (10.2%) when compared to AO (0.11%), indicating that closed-circuit operation was more conducive for the growth of electrogenic bacteria on the anodes. On the cathodes, Protebacteria was robust on CC while Bacteroidetes was more abundant on CO. Rhodobacter and Hydrogenophaga were also enriched on CC than CO, suggesting that these genera play a role in electron transfer from the cathode surface to the terminal electron acceptors in the bioelectrochemical MBR under closed-circuit operation. PMID:24705450
NASA Astrophysics Data System (ADS)
Li, Xiaohan; Dasika, Vaishno D.; Li, Ping-Chun; Ji, Li; Bank, Seth R.; Yu, Edward T.
2014-09-01
The use of InGaAs quantum wells with composition graded across the intrinsic region to increase open-circuit voltage in p-i-n GaAs/InGaAs quantum well solar cells is demonstrated and analyzed. By engineering the band-edge energy profile to reduce photo-generated carrier concentration in the quantum wells at high forward bias, simultaneous increases in both open-circuit voltage and short-circuit current density are achieved, compared to those for a structure with the same average In concentration, but constant rather than graded quantum well composition across the intrinsic region. This approach is combined with light trapping to further increase short-circuit current density.
Chen, Chun-Kai; Weng, Ming-Cheng; Chen, Tien-Wen; Huang, Mao-Hsiung
2013-11-01
This study evaluated the impact of severity of hemiparesis on oxygen uptake (VO2) response in post-acute stroke patients. Sixty-four patients with a mean poststroke interval of 8.6 ± 3.8 days underwent a ramp cardiopulmonary exercise test on a cycling ergometer to volitional termination. Mean peak VO2 (VO2peak) and work efficiency (ΔVO2/ΔWR) were measured by open-circuit spirometry during standard upright ergometer cycling. Severity of the hemiparetic lower limb was assessed by Brunnstrom's motor recovery stages lower extremity (BMRSL). VO2peak was 10% lower in hemiparetic leg with BMRSL V than in that with BMRSL VI, 20% lower in BMRSL IV, and 50% lower in BMRSL III. ΔVO2/ΔWR was higher for the group with increased BMRSL. The relations were consistent after adjustment for age, sex, body mass index, stroke type, hemiparetic side, modified Ashworth Scale, time poststroke, comorbidities, and medications. Our findings revealed that O2peak is dependent on the severity of hemiparesis in leg, and along with ΔO2/ΔWR closely related to the severity of hemiparesis in post-acute stroke patients, regardless of the types and locations of lesion after stroke, as well as the differences in comorbidities and medications. Copyright © 2013. Published by Elsevier B.V.
Spirometry is a painless study of air volume and flow rate within the lungs. Spirometry is frequently used to evaluate lung function in people with obstructive or restrictive lung diseases such as asthma or cystic fibrosis.
2015-02-11
A similar risk-based approach may be appropriate for deploying military personnel. e) If DoD were to consider implementing a large- scale pre...quality of existing spirometry programs prior to considering a larger scale pre-deployment effort. Identifying an accelerated decrease in spirometry...baseline spirometry on a wider scale . e) Conduct pre-deployment baseline spirometry if there is a significant risk of exposure to a pulmonary hazard based
2013-01-01
Background Spirometry testing is essential to confirm an obstructive lung disease, but studies have reported that a large proportion of patients diagnosed with COPD or asthma have no history of spirometry testing. Also, it has been shown that many patients are prescribed medication for obstructive lung disease without a relevant diagnosis or spirometry test registered. General practice characteristics have been reported to influence diagnosis and management of several chronic diseases. However, these findings are inconsistent, and it is uncertain whether practice characteristics influence spirometry testing among patients receiving medication for obstructive lung disease. The aim of this study was therefore to examine if practice characteristics are associated with spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease. Methods A national register-based cohort study was performed. All patients over 18 years receiving first-time prescriptions for medication targeting obstructive lung disease in 2008 were identified and detailed patient-specific data on sociodemographic status and spirometry tests were extracted. Information on practice characteristics like number of doctors, number of patients per doctor, training practice status, as well as age and gender of the general practitioners was linked to each medication user. Results Partnership practices had a higher odds ratio (OR) of performing spirometry compared with single-handed practices (OR 1.24, CI 1.09-1.40). We found a significant association between increasing general practitioner age and decreasing spirometry testing. This tendency was most pronounced among partnership practices, where doctors over 65 years had the lowest odds of spirometry testing (OR 0.25, CI 0.10-0.61). Training practice status was significantly associated with spirometry testing among single-handed practices (OR 1.40, CI 1.10-1.79). Conclusion Some of the variation in spirometry testing among patients receiving first-time prescriptions for medication targeting obstructive lung disease was associated with practice characteristics. This variation in performance may indicate a potential for quality improvement. PMID:23923987
Pérez-Padilla, Rogelio; Vázquez-García, Juan Carlos; Márquez, María Nelly; Menezes, Ana Maria B
2008-08-01
We report the characteristics of a centralized spirometry quality-control program developed for a population-based survey of the prevalence of chronic obstructive pulmonary disease in 5 cities: São Paulo, Brazil; México City, México; Montevideo, Uruguay; Santiago, Chile; and Caracas, Venezuela (the Latin American Project for the Investigation of Obstructive Lung Diseases [PLATINO]). We developed and used a 3-level quality-control system. Level 1: The spirometer used in the survey (EasyOne), gives quality-control messages to the user/clinician. All the spirometry technicians were trained by the same team, with the aim of meeting what became the 2005 spirometry quality criteria of the American Thoracic Society/European Respiratory Society (ATS/ERS). Level 2: In each of the 5 cities a local supervisor identified poor-quality spirometries that needed to be repeated. Level 3: Once a week during the survey, all spirometry results were sent via e-mail to the study's quality-control center in México City for review and feedback. In the overall totals at the end of the study, 94% of the 5,315 subjects had spirometries that met the 1994 ATS quality criteria, and 89% met the 2005 ATS/ERS criteria. In their overall totals at the end of the study, 90% of the 64 spirometry technicians were successful in getting 86% of their subjects to meet the 1994 ATS criteria, and got 75% of their subjects to meet the 2005 ATS/ERS criteria. In the first 10 subjects they tested, 90% of the 64 spirometry technicians were successful in getting 70% of their subjects to meet the 1994 ATS criteria, and got 60% of their subjects to meet the 2005 ATS/ERS criteria. Standardization of equipment, training, and supervision of spirometry is essential in a multinational spirometry survey. Centralized quality control can be done via e-mail with good reliability and low cost.
Anand, R.
2016-01-01
Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery. PMID:27525116
Alaparthi, Gopala Krishna; Augustine, Alfred Joseph; Anand, R; Mahale, Ajith
2016-01-01
Objective. To evaluate the effects of diaphragmatic breathing exercises and flow and volume-oriented incentive spirometry on pulmonary function and diaphragm excursion in patients undergoing laparoscopic abdominal surgery. Methodology. We selected 260 patients posted for laparoscopic abdominal surgery and they were block randomization as follows: 65 patients performed diaphragmatic breathing exercises, 65 patients performed flow incentive spirometry, 65 patients performed volume incentive spirometry, and 65 patients participated as a control group. All of them underwent evaluation of pulmonary function with measurement of Forced Vital Capacity (FVC), Forced Expiratory Volume in the first second (FEV1), Peak Expiratory Flow Rate (PEFR), and diaphragm excursion measurement by ultrasonography before the operation and on the first and second postoperative days. With the level of significance set at p < 0.05. Results. Pulmonary function and diaphragm excursion showed a significant decrease on the first postoperative day in all four groups (p < 0.001) but was evident more in the control group than in the experimental groups. On the second postoperative day pulmonary function (Forced Vital Capacity) and diaphragm excursion were found to be better preserved in volume incentive spirometry and diaphragmatic breathing exercise group than in the flow incentive spirometry group and the control group. Pulmonary function (Forced Vital Capacity) and diaphragm excursion showed statistically significant differences between volume incentive spirometry and diaphragmatic breathing exercise group (p < 0.05) as compared to that flow incentive spirometry group and the control group. Conclusion. Volume incentive spirometry and diaphragmatic breathing exercise can be recommended as an intervention for all patients pre- and postoperatively, over flow-oriented incentive spirometry for the generation and sustenance of pulmonary function and diaphragm excursion in the management of laparoscopic abdominal surgery.
Mechanisms limiting the performance of large grain polycrystalline silicon solar cells
NASA Technical Reports Server (NTRS)
Culik, J. S.; Alexander, P.; Dumas, K. A.; Wohlgemuth, J. W.
1984-01-01
The open-circuit voltage and short-circuit current of large-grain (1 to 10 mm grain diameter) polycrystalline silicon solar cells is determined by the minority-carrier diffusion length within the bulk of the grains. This was demonstrated by irradiating polycrystalline and single-crystal (Czochralski) silicon solar cells with 1 MeV electrons to reduce their bulk lifetime. The variation of short-circuit current with minority-carrier diffusion length for the polycrystalline solar cells is identical to that of the single-crystal solar cells. The open-circuit voltage versus short-circuit current characteristic of the polycrystalline solar cells for reduced diffusion lengths is also identical to that of the single-crystal solar cells. The open-circuit voltage of the polycrystalline solar cells is a strong function of quasi-neutral (bulk) recombination, and is reduced only slightly, if at all, by grain-boundary recombination.
Incentive spirometry following thoracic surgery: what should we be doing?
Agostini, Paula; Singh, Sally
2009-06-01
Thoracic surgery may cause reduced respiratory function and pulmonary complications, with associated increased risk of mortality. Postoperative physiotherapy aims to reverse atelectasis and secretion retention, and may include incentive spirometry. To review the evidence for incentive spirometry, examining the physiological basis, equipment and its use following thoracic surgery. MEDLINE was searched from 1950 to January 2008, EMBASE was searched from 1980 to January 2008, and CINAHL was searched from 1982 to January 2008, all using the OVID interface. The search term was: '[incentive spirometry.mp]'. The Cochrane Library was searched using the terms 'incentive spirometry' and 'postoperative physiotherapy'. The Chartered Society of Physiotherapy Resource Centre was also searched, and a hand search was performed to follow-up references from the retrieved studies. Non-scientific papers were excluded, as were papers that did not relate to thoracic surgery or the postoperative treatment of patients with incentive spirometry. Initially, 106 studies were found in MEDLINE, 99 in EMBASE and 42 in CINAHL. Eight references were found in the Cochrane Library and one paper in the Chartered Society of Physiotherapy Resource Centre. Four studies and one systematic review investigating the effects of postoperative physiotherapy and incentive spirometry in thoracic surgery patients were selected and reviewed. Physiological evidence suggests that incentive spirometry may be appropriate for lung re-expansion following major thoracic surgery. Based on sparse literature, postoperative physiotherapy regimes with, or without, the use of incentive spirometry appear to be effective following thoracic surgery compared with no physiotherapy input.
Santos, Thalita Vilaboim; Ruas, Gualberto; Sande de Souza, Luciane Aparecida Pascucci; Volpe, Marcia Souza
2012-12-01
Breathing exercises (BE), incentive spirometry and positioning are considered treatment modalities to achieve lung re-expansion. This study evaluated the influence of incentive spirometry and forward leaning on inspired tidal volumes (V(T)) and electromyographic activity of inspiratory muscles during BE. Four modalities of exercises were investigated: deep breathing, spirometry using both flow and volume-oriented devices, and volume-oriented spirometry after modified verbal instruction. Twelve healthy subjects aged 22.7 ± 2.1 years were studied. Surface electromyography activity of diaphragm, external intercostals, sternocleidomastoid and scalenes was recorded. Comparisons among the three types of exercises, without considering spirometry after modified instruction, showed that electromyographic activity and V(T) were lower during volume-oriented spirometry (p = 0.000, p = 0.054, respectively). Forward leaning resulted in a lower V(T) when compared to upright sitting (p = 0.000), but electromyographic activity was not different (p = 0.606). Inspired V(T) and electromyographic activity were higher during volume-oriented spirometry performed after modified instruction when compared with the flow-oriented device (p = 0.027, p = 0.052, respectively). In conclusion BE using volume-oriented spirometry before modified instruction resulted in a lower work of breathing as a result of a lower V(T) and was not a consequence of the device type used. Forward leaning might not be assumed by healthy subjects during situations of augmented respiratory demand. Copyright © 2012 Elsevier Ltd. All rights reserved.
Open circuit voltage-decay behavior in amorphous p-i-n solar due to injection
NASA Astrophysics Data System (ADS)
Smrity, Manu; Dhariwal, S. R.
2018-05-01
The paper deals with the basic recombination processes at the dangling bond and the band tail states at various levels of injection, expressed in terms of short-circuit current density and their role in the behavior of amorphous solar cells. As the level of injection increases the fill factor decreases whereas the open circuit voltage increases very slowly, showing a saturation tendency. Calculations have been done for two values of tail state densities and shows that with an increase in tail state densities both, the fill factor and open circuit voltage decreases, results an overall degradation of the solar cell.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bobrov, Yu. K.; Zhuravkov, I. V.; Ostapenko, E. I.
2010-12-15
The effect of air gap breakdown voltage reduction in the circuit with an opening microswitch is substantiated from the physical point of view. This effect can be used to increase the efficiency of lightning protection system with a rod lightning protector. The processes which take place in the electric circuit of a lightning protector with a microswitch during a voltage breakdown are investigated. Openings of the microswitch are shown to lead to resonance overvoltages in the dc circuit and, as a result, efficient reduction in the breakdown voltage in a lightning protector-thundercloud air gap.
Thermally-induced voltage alteration for integrated circuit analysis
Cole, Jr., Edward I.
2000-01-01
A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.
Wang, Shigang; Spencer, Shannon B; Woitas, Karl; Glass, Kristen; Kunselman, Allen R; Ündar, Akif
2017-01-01
The objective of this study is to evaluate the impact of an open or closed recirculation line on flow rate, circuit pressure, and hemodynamic energy transmission in simulated neonatal extracorporeal life support (ECLS) systems. The two neonatal ECLS circuits consisted of a Maquet HL20 roller pump (RP group) or a RotaFlow centrifugal pump (CP group), Quadrox-iD Pediatric oxygenator, and Biomedicus arterial and venous cannulae (8 Fr and 10 Fr) primed with lactated Ringer's solution and packed red blood cells (hematocrit 35%). Trials were conducted at flow rates ranging from 200 to 600 mL/min (200 mL/min increments) with a closed or open recirculation line at 36°C. Real-time pressure and flow data were recorded using a custom-based data acquisition system. In the RP group, the preoxygenator flow did not change when the recirculation line was open while the prearterial cannula flow decreased by 15.7-20.0% (P < 0.01). Circuit pressure, total circuit pressure drop, and hemodynamic energy delivered to patients also decreased (P < 0.01). In the CP group, the prearterial cannula flow did not change while preoxygenator flow increased by 13.6-18.8% (P < 0.01). Circuit pressure drop and hemodynamic energy transmission remained the same. The results showed that the shunt of an open recirculation line could decrease perfusion flow in patients in the ECLS circuit using a roller pump, but did not change perfusion flow in the circuit using a centrifugal pump. An additional flow sensor is needed to monitor perfusion flow in patients if any shunts exist in the ECLS circuit. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Tomich, Georgia Miranda; França, Danielle Corrêa; Diniz, Marco Túlio Costa; Britto, Raquel Rodrigues; Sampaio, Rosana Ferreira; Parreira, Verônica Franco
2010-01-01
To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incentive spirometry with a volume-oriented device were performed in random order. Respiratory inductive plethysmography was used in order to measure respiratory variables and thoracoabdominal motion. Comparisons among the three exercises showed significant differences: tidal volume was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing; the respiratory rate was lower during incentive spirometry with the volume-oriented device than during incentive spirometry with the flow-oriented device; and minute ventilation was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing. Rib cage motion did not vary during breathing exercises, although there was an increase in thoracoabdominal asynchrony, especially during incentive spirometry with the flow-oriented device. Among the breathing exercises evaluated, incentive spirometry with the volume-oriented device provided the best results, because it allowed slower, deeper inhalation.
Integrated circuit failure analysis by low-energy charge-induced voltage alteration
Cole, E.I. Jr.
1996-06-04
A scanning electron microscope apparatus and method are described for detecting and imaging open-circuit defects in an integrated circuit (IC). The invention uses a low-energy high-current focused electron beam that is scanned over a device surface of the IC to generate a charge-induced voltage alteration (CIVA) signal at the location of any open-circuit defects. The low-energy CIVA signal may be used to generate an image of the IC showing the location of any open-circuit defects. A low electron beam energy is used to prevent electrical breakdown in any passivation layers in the IC and to minimize radiation damage to the IC. The invention has uses for IC failure analysis, for production-line inspection of ICs, and for qualification of ICs. 5 figs.
Integrated circuit failure analysis by low-energy charge-induced voltage alteration
Cole, Jr., Edward I.
1996-01-01
A scanning electron microscope apparatus and method are described for detecting and imaging open-circuit defects in an integrated circuit (IC). The invention uses a low-energy high-current focused electron beam that is scanned over a device surface of the IC to generate a charge-induced voltage alteration (CIVA) signal at the location of any open-circuit defects. The low-energy CIVA signal may be used to generate an image of the IC showing the location of any open-circuit defects. A low electron beam energy is used to prevent electrical breakdown in any passivation layers in the IC and to minimize radiation damage to the IC. The invention has uses for IC failure analysis, for production-line inspection of ICs, and for qualification of ICs.
Edelen, Cheryl; Perlow, Michael
2002-03-01
The purpose of this study was to compare the effects of opioid analgesics and relaxation as interventions for incentive spirometry in postcardiovascular surgery patients. With the use of incentive spirometry change scores from pre- to posttreatment, 72 patients received either relaxation, opioid analgesia, or no intervention. Pre- to posttreatment differences in achieved spirometry volumes were significantly different for the 3 groups (F[2, 69] = 7.32; p =.002), whereas no difference in spirometry volume was found between the opioid and relaxation groups. Relaxation was as effective as opioid analgesia in permitting postcardiovascular surgical patients to deep breathe.
Efficacy of a Virtual Teaching Assistant in an Open Laboratory Environment for Electric Circuits
ERIC Educational Resources Information Center
Saleheen, Firdous; Wang, Zicong; Picone, Joseph; Butz, Brian P.; Won, Chang-Hee
2018-01-01
In order to provide an on-demand, open electrical engineering laboratory, we developed an innovative software-based Virtual Open Laboratory Teaching Assistant (VOLTA). This web-based virtual assistant provides laboratory instructions, equipment usage videos, circuit simulation assistance, and hardware implementation diagnostics. VOLTA allows…
The reliability and utility of spirometry performed on people with asthma in community pharmacies.
Lei Burton, Deborah; LeMay, Kate S; Saini, Bandana; Smith, Lorraine; Bosnic-Anticevich, Sinthia; Southwell, Phillipa; Cooke, Julie; Emmerton, Lynne; Stewart, Kay; Krass, Ines; Reddel, Helen; Armour, Carol
2015-01-01
To investigate the reliability and the utility of spirometry generated by community pharmacists participating in two large asthma intervention trials of 892 people. The Pharmacy Asthma Care Program (PACP) and the Pharmacy Asthma Management Service (PAMS) involved up to four visits to the pharmacy over 6 months for counseling and goal setting. Pharmacists performed spirometry according to ATS/ERS guidelines to inform management. The proportion of A-E, F quality tests, as per EasyOne QC grades, were recorded. Lung function results between visits and for participants referred/not referred to their general practitioner on the basis of spirometry were compared. Complete data from 2593 spirometry sessions were recorded, 68.5% of spirometry sessions achieved three acceptable tests with between-test repeatability of 150 ml or less (A or B quality), 96% of spirometry sessions included at least one test that met ATS/ERS acceptability criteria. About 39.1% of participants had FEV1/FVC values below the lower limit of normal (LNN), indicating a respiratory obstruction. As a result of the service, there was a significant increase in FEV1 and FEV1/FVC and asthma control. Lung function values were significantly poorer for participants referred to their general practitioner, compared with those not referred, on the basis of spirometry. Community pharmacists are able to reliably achieve spirometry results meeting ATS/ERS guidelines in people with asthma. Significant improvements in airway obstruction were demonstrated with the pharmacy services. Pharmacists interpreted lung function results to identify airway obstruction for referral, making this a useful technique for review of people with asthma in the community.
Marina Malanda, Nuria; López de Santa María, Elena; Gutiérrez, Asunción; Bayón, Juan Carlos; Garcia, Larraitz; Gáldiz, Juan B
2014-04-01
Forced spirometry is essential for diagnosing respiratory diseases and is widely used across levels of care. However, several studies have shown that spirometry quality in primary care is not ideal, with risks of misdiagnosis. Our objective was to assess the feasibility and performance of a telemedicine-based training and quality assurance program for forced spirometry in primary care. The two phases included (1) a 9-month pilot study involving 15 centers, in which spirometry tests were assessed by the Basque Office for Health Technology Assessment, and (2) the introduction of the program to all centers in the Public Basque Health Service. Technicians first received 4 h of training, and, subsequently, they sent all tests to the reference laboratory using the program. Quality assessment was performed in accordance with clinical guidelines (A and B, good; C-F, poor). In the first phase, 1,894 spirometry tests were assessed, showing an improvement in quality: acceptable quality tests increased from 57% at the beginning to 78% after 6 months and 83% after 9 months (p<0.001). In the second phase, 7,200 spirometry tests were assessed after the inclusion of 36 additional centers, maintaining the positive trend (61%, 87%, and 84% at the same time points; p<0.001). (1) The quality of spirometry tests improved in all centers. (2) The program provides a tool for transferring data that allows monitoring of its quality and training of technicians who perform the tests. (3) This approach is useful for improving spirometry quality in the routine practice of a public health system.
Ko, Sangwon; Hoke, Eric T; Pandey, Laxman; Hong, Sanghyun; Mondal, Rajib; Risko, Chad; Yi, Yuanping; Noriega, Rodrigo; McGehee, Michael D; Brédas, Jean-Luc; Salleo, Alberto; Bao, Zhenan
2012-03-21
Conjugated polymers with nearly planar backbones have been the most commonly investigated materials for organic-based electronic devices. More twisted polymer backbones have been shown to achieve larger open-circuit voltages in solar cells, though with decreased short-circuit current densities. We systematically impose twists within a family of poly(hexylthiophene)s and examine their influence on the performance of polymer:fullerene bulk heterojunction (BHJ) solar cells. A simple chemical modification concerning the number and placement of alkyl side chains along the conjugated backbone is used to control the degree of backbone twisting. Density functional theory calculations were carried out on a series of oligothiophene structures to provide insights on how the sterically induced twisting influences the geometric, electronic, and optical properties. Grazing incidence X-ray scattering measurements were performed to investigate how the thin-film packing structure was affected. The open-circuit voltage and charge-transfer state energy of the polymer:fullerene BHJ solar cells increased substantially with the degree of twist induced within the conjugated backbone--due to an increase in the polymer ionization potential--while the short-circuit current decreased as a result of a larger optical gap and lower hole mobility. A controlled, moderate degree of twist along the poly(3,4-dihexyl-2,2':5',2''-terthiophene) (PDHTT) conjugated backbone led to a 19% enhancement in the open-circuit voltage (0.735 V) vs poly(3-hexylthiophene)-based devices, while similar short-circuit current densities, fill factors, and hole-carrier mobilities were maintained. These factors resulted in a power conversion efficiency of 4.2% for a PDHTT:[6,6]-phenyl-C(71)-butyric acid methyl ester (PC(71)BM) blend solar cell without thermal annealing. This simple approach reveals a molecular design avenue to increase open-circuit voltage while retaining the short-circuit current.
Moor, C C; Wapenaar, M; Miedema, J R; Geelhoed, J J M; Chandoesing, P P; Wijsenbeek, M S
2018-05-29
In idiopathic pulmonary fibrosis (IPF), home monitoring experiences are limited, not yet real-time available nor implemented in daily care. We evaluated feasibility and potential barriers of a new home monitoring program with real-time wireless home spirometry in IPF. Ten patients with IPF were asked to test this home monitoring program, including daily home spirometry, for four weeks. Measurements of home and hospital spirometry showed good agreement. All patients considered real-time wireless spirometry useful and highly feasible. Both patients and researchers suggested relatively easy solutions for the identified potential barriers regarding real-time home monitoring in IPF.
Rectenna for high-voltage applications
NASA Technical Reports Server (NTRS)
Epp, Larry W. (Inventor); Khan, Abdur R. (Inventor)
2002-01-01
An energy transfer system is disclosed. The system includes patch elements, shielding layers, and energy rectifying circuits. The patch elements receive and couple radio frequency energy. The shielding layer includes at least one opening that allows radio frequency energy to pass through. The openings are formed and positioned to receive the radio frequency energy and to minimize any re-radiating back toward the source of energy. The energy rectifying circuit includes a circuit for rectifying the radio frequency energy into dc energy. A plurality of energy rectifying circuits is arranged in an array to provide a sum of dc energy generated by the energy rectifying circuit.
Swanney, Maureen P; O'Dea, Christopher A; Ingram, Emily R; Rodwell, Leanne T; Borg, Brigitte M
2017-10-01
Spirometry training courses are provided by health services and training organizations to enable widespread use of spirometry testing for patient care or for monitoring health. The primary outcome of spirometry training courses should be to enable participants to perform spirometry to international best practice, including testing of subjects, quality assurance and interpretation of results. Where valid results are not achieved or quality assurance programmes identify errors in devices, participants need to be able to adequately manage these issues in accordance with best practice. It is important that potential participants are confident in the integrity of the course they attend and that the course meets their expectations in terms of training. This position statement lists the content that the Australian and New Zealand Society of Respiratory Science (ANZSRS) has identified as required in a spirometry training course to adequately meet the primary outcomes mentioned above. The content requirements outlined in this position statement are based on the current international spirometry standards set out by the American Thoracic Society and European Respiratory Society. Furthermore, recommendations around course delivery for theoretical and practical elements of spirometry testing and post-course assessment are outlined in this statement. © 2017 The Authors. Respirology published by John Wiley & Sons Australia, Ltd on behalf of Asian Pacific Society of Respirology.
Guimarães, Michele Mf; El Dib, Regina; Smith, Andrew F; Matos, Delcio
2009-07-08
Upper abdominal surgical procedures are associated with a high risk of postoperative pulmonary complications. The risk and severity of postoperative pulmonary complications can be reduced by the judicious use of therapeutic manoeuvres that increase lung volume. Our objective was to assess the effect of incentive spirometry (IS) compared to no therapy, or physiotherapy including coughing and deep breathing, on all-cause postoperative pulmonary complications and mortality in adult patients admitted for upper abdominal surgery. To assess the effects of incentive spirometry compared to no such therapy (or other therapy) on all-cause postoperative pulmonary complications (atelectasis, acute respiratory inadequacy) and mortality in adult patients admitted for upper abdominal surgery. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2006, Issue 3), MEDLINE, EMBASE, and LILACS (from inception to July 2006). There were no language restrictions. We included randomized controlled trials of incentive spirometry in adult patients admitted for any type of upper abdominal surgery, including patients undergoing laparoscopic procedures. Two authors independently assessed trial quality and extracted data. We included 11 studies with a total of 1754 participants. Many trials were of only moderate methodological quality and did not report on compliance with the prescribed therapy. Data from only 1160 patients could be included in the meta-analysis. Three trials (120 patients) compared the effects of incentive spirometry with no respiratory treatment. Two trials (194 patients) compared incentive spirometry with deep breathing exercises. Two trials (946 patients) compared incentive spirometry with other chest physiotherapy. All showed no evidence of a statistically significant effect of incentive spirometry. There was no evidence that incentive spirometry is effective in the prevention of pulmonary complications. We found no evidence regarding the effectiveness of the use of incentive spirometry for prevention of postoperative pulmonary complications in upper abdominal surgery. This review underlines the urgent need to conduct well-designed trials in this field. There is a case for large randomized trials of high methodological rigour in order to define any benefit from the use of incentive spirometry regarding mortality.
Color Coding of Circuit Quantities in Introductory Circuit Analysis Instruction
ERIC Educational Resources Information Center
Reisslein, Jana; Johnson, Amy M.; Reisslein, Martin
2015-01-01
Learning the analysis of electrical circuits represented by circuit diagrams is often challenging for novice students. An open research question in electrical circuit analysis instruction is whether color coding of the mathematical symbols (variables) that denote electrical quantities can improve circuit analysis learning. The present study…
Staged depressurization system
Schulz, T.L.
1993-11-02
A nuclear reactor having a reactor vessel disposed in a containment shell is depressurized in stages using depressurizer valves coupled in fluid communication with the coolant circuit. At least one sparger submerged in the in-containment refueling water storage tank which can be drained into the containment sump communicates between one or more of the valves and an inside of the containment shell. The depressurizer valves are opened in stages, preferably at progressively lower coolant levels and for opening progressively larger flowpaths to effect depressurization through a number of the valves in parallel. The valves can be associated with a pressurizer tank in the containment shell, coupled to a coolant outlet of the reactor. At least one depressurization valve stage openable at a lowest pressure is coupled directly between the coolant circuit and the containment shell. The reactor is disposed in the open sump in the containment shell, and a further valve couples the open sump to a conduit coupling the refueling water storage tank to the coolant circuit for adding water to the coolant circuit, whereby water in the containment shell can be added to the reactor from the open sump. 4 figures.
Staged depressurization system
Schulz, Terry L.
1993-01-01
A nuclear reactor having a reactor vessel disposed in a containment shell is depressurized in stages using depressurizer valves coupled in fluid communication with the coolant circuit. At least one sparger submerged in the in-containment refueling water storage tank which can be drained into the containment sump communicates between one or more of the valves and an inside of the containment shell. The depressurizer valves are opened in stages, preferably at progressively lower coolant levels and for opening progressively larger flowpaths to effect depressurization through a number of the valves in parallel. The valves can be associated with a pressurizer tank in the containment shell, coupled to a coolant outlet of the reactor. At least one depressurization valve stage openable at a lowest pressure is coupled directly between the coolant circuit and the containment shell. The reactor is disposed in the open sump in the containment shell, and a further valve couples the open sump to a conduit coupling the refueling water storage tank to the coolant circuit for adding water to the coolant circuit, whereby water in the containment shell can be added to the reactor from the open sump.
Multiconductor Short/Open Cable Tester
NASA Technical Reports Server (NTRS)
Eichenberg, Dennis
1994-01-01
Frequent or regular testing of multiconductor cables terminated in multipin conductors tedious, if not impossible, task. This inexpensive circuit simplifies open/short testing and is amenable to automation. In operation, pair of connectors selected to match pair of connectors installed on each of cables to be tested. As many connectors accommodated as required, and each can have as many conductors as required. Testing technique implemented with this circuit automated easily with electronic controls and computer interface. Printout provides status of each conductor in cable, indicating which, if any, of conductors has open or short circuit.
A Study of a Mulilayer BPF with Attenuation Poles by Using Folded Resonators with Open-Circuited End
NASA Astrophysics Data System (ADS)
Kasamai, Masashi; Usie, Masahiko; Wada, Kouji
We propose a multilayer bandpass filter(BPF) with attenuation poles using folded resonators with open-circuited end. Firstly, the basic characteristics of a folded resonator with open-circuited end under the change of the parameters is examined by an electromagnetic simulator. Secondly, 3-pole multilayer BPFs using the resonators above are proposed, simulated and experimented. As a result, the bandpass characteristics with attenuation poles near the lower and higher side of the center frequency is realized by the proposed structure.
Deng, Wanyuan; Gao, Ke; Yan, Jun; Liang, Quanbin; Xie, Yuan; He, Zhicai; Wu, Hongbin; Peng, Xiaobin; Cao, Yong
2018-03-07
In this study, we demonstrate that remarkably reduced open-circuit voltage in highly efficient organic solar cells (OSCs) from a blend of phenyl-C 61 -butyric acid methyl ester and a recently developed conjugated small molecule (DPPEZnP-THD) upon solvent vapor annealing (SVA) is due to two independent sources: increased radiative recombination and increased nonradiative recombination. Through the measurements of electroluminescence due to the emission of the charge-transfer state and photovoltaic external quantum efficiency measurement, we can quantify that the open-circuit voltage losses in a device with SVA due to the radiative recombination and nonradiative recombination are 0.23 and 0.31 V, respectively, which are 0.04 and 0.07 V higher than those of the as-cast device. Despite of the reduced open-circuit voltage, the device with SVA exhibited enhanced dissociation of charge-transfer excitons, leading to an improved short-circuit current density and a remarkable power conversion efficiency (PCE) of 9.41%, one of the best for solution-processed OSCs based on small-molecule donor materials. Our study also clearly shows that removing the nonradiative recombination pathways and/or suppressing energetic disorder in the active layer would result in more long-lived charge carriers and enhanced open-circuit voltage, which are prerequisites for further improving the PCE.
Primary care spirometry: test quality and the feasibility and usefulness of specialist reporting
White, Patrick; Wong, Wun; Fleming, Tracey; Gray, Barry
2007-01-01
Background Provision of spirometry for chronic obstructive pulmonary disease (COPD) is a new requirement in primary care. Effective spirometry requires that tests and interpretations meet international criteria. Aim To assess the feasibility and usefulness of remote specialist reporting of primary care spirometry. Design of study Comparison of reporting by primary care clinicians and respiratory specialists of consecutive primary care spirometry tests. Setting South London primary care teams with patient lists ≥6000. Method Feasibility of remote reporting of spirometry was assessed by the frequency of electronic mailing of tests. Usefulness of remote reporting was defined by the frequency that specialist reports made a clinically significant addition. Usefulness was assessed by measuring agreement (κ) between primary care reports and those of specialists. Clinically significant disagreements were analysed with respect to test quality, diagnosis, and severity. Results Six practices emailed 312 tests over 3 months. Forty-nine tests sent without indices or curves (flow volume and time volume) were excluded. Mean age of patients tested was 65 years and 52% were female. Mean predicted forced expiratory volume in the first second (FEV1) was 69%. Clinically significant disagreements were identified in the interpretation of acceptability (quality) of 67/212 (32%) tests (κ = 0.07; 95% confidence interval [CI] = 0 to 0.24), of diagnosis in 49/168 (29%) tests (κ = 0.39; 95% CI = 0.25 to 0.55), and of severity in 62/191 (32%) tests (κ = 0.53; 95% CI = 0.43 to 0.63). Conclusion Remote reporting of primary care spirometry was feasible. Its usefulness was confirmed by the high rate of additional clinically significant information to the reports of primary care clinicians. The quality of primary care spirometry was so unsatisfactory that remote reporting of tests may be a means of establishing adequate spirometry. PMID:17761057
49 CFR 236.731 - Controller, circuit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Controller, circuit. 236.731 Section 236.731 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Controller, circuit. A device for opening and closing electric circuits. ...
Is incentive spirometry effective following thoracic surgery?
Agostini, Paula; Calvert, Rachel; Subramanian, Hariharan; Naidu, Babu
2008-04-01
A best evidence topic in thoracic surgery was written according to a structured protocol. The question addressed was whether incentive spirometry is a useful intervention for patients after thoracic surgery. Altogether 255 papers were found using the reported search, of which seven represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude that incentive spirometry is a relatively good measure of lung function and may be used to assess respiratory recovery in the days after thoracic surgery. Physiotherapy either with or without incentive spirometry reduces the incidence of postoperative complications and improves lung function but there is currently no evidence that incentive spirometry in itself could either replace or significantly augment the work of the physiotherapists. Clinicians should be aware that while incentive spirometry can provide an assessment of lung recovery, well-organised and regular physiotherapy remains the most effective mechanism to augment their patient's recovery and avoid postoperative complications.
Demonstration of a High Open-Circuit Voltage GaN Betavoltaic Microbattery
NASA Astrophysics Data System (ADS)
Cheng, Zai-Jun; San, Hai-Sheng; Chen, Xu-Yuan; Liu, Bo; Feng, Zhi-Hong
2011-07-01
A high open-circuit voltage betavoltaic microbattery based on a GaN p-i-n diode is demonstrated. Under the irradiation of a 4×4 mm2 planar solid 63Ni source with an activity of 2 mCi, the open-circuit voltage Voc of the fabricated single 2×2mm2 cell reaches as high as 1.62 V, the short-circuit current density Jsc is measured to be 16nA/cm2. The microbattery has a fill factor of 55%, and the energy conversion efficiency of beta radiation into electricity reaches to 1.13%. The results suggest that GaN is a highly promising potential candidate for long-life betavoltaic microbatteries used as power supplies for microelectromechanical system devices.
Harris, David J; Hilliard, Paul E; Jewell, Elizabeth S; Brummett, Chad M
2015-01-01
Effective use of postoperative incentive spirometry improves patient outcomes but is limited by pain after thoracic and upper abdominal surgery. Thoracic epidurals are frequently used to provide analgesia and attenuate postoperative pulmonary dysfunction. We hypothesized that, in patients with thoracic epidurals for thoracic and abdominal surgery, high pain scores would be associated with poorer incentive spirometry performance, even when accounting for other variables. Retrospective study of 468 patients who underwent upper abdominal or thoracic surgery using postoperative thoracic epidural analgesia between June 1, 2009, and August 31, 2013, at a single tertiary academic center. The association between incentive spirometry performance and pain was assessed as the primary outcome. Other independent predictors of incentive spirometry performance were also identified. Postoperative incentive spirometry performance was found to be inversely proportional to pain score, which correlated significantly stronger with deep breathing pain compared with pain at rest (-0.33 vs -0.14 on postoperative day 1; -0.23 vs -0.12 on postoperative day 2). Pain with deep breathing was independently associated with poorer incentive spirometry performance in the multivariable linear regression model (P < 0.0001), as was increasing age, female sex, thoracic surgery, and higher American Society of Anesthesiologists (ASA) physical status score. The present study suggests that pain with deep breathing is more indicative of thoracic epidural efficacy than is pain at rest. Furthermore, incentive spirometry performance could be used as another indicator of thoracic epidural efficacy. This may be particularly useful in patients reporting high pain scores postoperatively.
Feasibility of spirometry in preschool children.
Veras, Tiago Neves; Pinto, Leonardo Araujo
2011-01-01
To determine the rate at which satisfactory spirometry results are obtained (spirometry success rate) in preschool children. We analyzed the spirometry results of children ≤ 6 years of age. All tests were conducted between June of 2009 and February of 2010 in the Pulmonary Function Laboratory of the Hospital Infantil Jeser Amarante Faria, located in the city of Joinville, Brazil. The spirometry program employed features an animated incentive (soap bubbles). The procedures were performed by a pediatric pulmonologist, in accordance with the reproducibility and acceptability criteria recommended by the American Thoracic Society. We attempted to achieve an expiratory time of at least 1 s. The following parameters were measured: FVC, FEV0.5, FEV1, and the FEV1/FVC ratio. Our sample comprised 74 children. The spirometry success rate was 82%. Although the performance improved with age, the difference between younger and older children was not significant (p > 0.05). An average of 6.6 attempts/test were needed in order to achieve acceptable, reproducible curves. All 61 successful tests produced satisfactory FEV0.5 and FEV1 values. By calculating Z scores, we found that 21.6% of the children presented with an obstructive pattern. In our sample, the spirometry success rate was high, showing that spirometry is a valid method for assessing pulmonary function in preschool children. The high success rate in our sample might be attributable to the use of an incentive and to the fact that the tests were performed by professionals specializing in pediatrics.
Li-Ion Battery By-Pass Removal Qualification
NASA Astrophysics Data System (ADS)
Borthomieu, Y.; Pasquier, E.
2005-05-01
The reasons of the by-pass use on Space batteries is to avoid open circuit, short-circuit and dramatic performances drift on the power system. By-pass diodes are currently used in NiH2 batteries due to the high probability of open circuit at cell level. This probability is mainly linked to the possibility to have a hydrogen leak within the pressure vessel due to the high operating pressure (70 bars) that can induce cell open circuit.For the Lithium-Ion batteries, first items had bypass implemented by similarity, but:All the cell failure cases have been analyzed at battery level:- Cell Open circuit:In contrast to NiCd and NiH2 cells, Li-Ion cells can be put in parallel due to the fact the open circuit voltage (OCV) is linked to the State Of Charge (SOC).With cells in parallel, a battery open circuit failure can never be encountered even with a cell in open circuit.- Cell Short circuit:In case of cell short, the entire cells within the module will be shorted.- Cell capacity spread:If the capacities of cells in series are strongly diverging, the worst module limits the battery. In case the battery is no more able to deliver the requested power for which it was designed, the worst module has to be reversed. In reversal, a Li-Ion cell is self-shorted. So, the strong capacity decrease in one module leads to the short of this module.These three failure cases cover all the possible Li-Ion failure root causes.Considering these three events, the analysis demonstrates that the Li-Ion battery still functions in any case without any by-pass system because the design of the battery size always takes into account the loss of one module.Nevertheless, the by-pass removal should allow to:- Improve the battery reliability as each bypass unit represents a single - Reduce by at least 30 % of the total price of the battery,- Reduce significant weight at battery level,- Shorten the battery manufacturing lead time (at least8 months for by-pass purchasing), - Avoid US export licenses.A formal qualification of a Li-Ion battery without by- pass system is on going in the frame of an ESA ARTES 3 contract.
Thermocouple-Signal-Conditioning Circuit
NASA Technical Reports Server (NTRS)
Simon, Richard A.
1991-01-01
Thermocouple-signal-conditioning circuit acting in conjunction with thermocouple, exhibits electrical behavior of voltage in series with resistance. Combination part of input bridge circuit of controller. Circuit configured for either of two specific applications by selection of alternative resistances and supply voltages. Includes alarm circuit detecting open circuit in thermocouple and provides off-scale output to signal malfunctions.
Bartynski, Andrew N; Gruber, Mark; Das, Saptaparna; Rangan, Sylvie; Mollinger, Sonya; Trinh, Cong; Bradforth, Stephen E; Vandewal, Koen; Salleo, Alberto; Bartynski, Robert A; Bruetting, Wolfgang; Thompson, Mark E
2015-04-29
Low open-circuit voltages significantly limit the power conversion efficiency of organic photovoltaic devices. Typical strategies to enhance the open-circuit voltage involve tuning the HOMO and LUMO positions of the donor (D) and acceptor (A), respectively, to increase the interfacial energy gap or to tailor the donor or acceptor structure at the D/A interface. Here, we present an alternative approach to improve the open-circuit voltage through the use of a zinc chlorodipyrrin, ZCl [bis(dodecachloro-5-mesityldipyrrinato)zinc], as an acceptor, which undergoes symmetry-breaking charge transfer (CT) at the donor/acceptor interface. DBP/ZCl cells exhibit open-circuit voltages of 1.33 V compared to 0.88 V for analogous tetraphenyldibenzoperyflanthrene (DBP)/C60-based devices. Charge transfer state energies measured by Fourier-transform photocurrent spectroscopy and electroluminescence show that C60 forms a CT state of 1.45 ± 0.05 eV in a DBP/C60-based organic photovoltaic device, while ZCl as acceptor gives a CT state energy of 1.70 ± 0.05 eV in the corresponding device structure. In the ZCl device this results in an energetic loss between E(CT) and qV(OC) of 0.37 eV, substantially less than the 0.6 eV typically observed for organic systems and equal to the recombination losses seen in high-efficiency Si and GaAs devices. The substantial increase in open-circuit voltage and reduction in recombination losses for devices utilizing ZCl demonstrate the great promise of symmetry-breaking charge transfer in organic photovoltaic devices.
Fabrication of multijunction high voltage concentrator solar cells by integrated circuit technology
NASA Technical Reports Server (NTRS)
Valco, G. J.; Kapoor, V. J.; Evans, J. C., Jr.; Chai, A.-T.
1981-01-01
Standard integrated circuit technology has been developed for the design and fabrication of planar multijunction (PMJ) solar cell chips. Each 1 cm x 1 cm solar chip consisted of six n(+)/p, back contacted, internally series interconnected unit cells. These high open circuit voltage solar cells were fabricated on 2 ohm-cm, p-type 75 microns thick, silicon substrates. A five photomask level process employing contact photolithography was used to pattern for boron diffusions, phorphorus diffusions, and contact metallization. Fabricated devices demonstrated an open circuit voltage of 3.6 volts and a short circuit current of 90 mA at 80 AMl suns. An equivalent circuit model of the planar multi-junction solar cell was developed.
NASA Astrophysics Data System (ADS)
Zhang, Zhen; Xia, Changliang; Yan, Yan; Geng, Qiang; Shi, Tingna
2017-08-01
Due to the complicated rotor structure and nonlinear saturation of rotor bridges, it is difficult to build a fast and accurate analytical field calculation model for multilayer interior permanent magnet (IPM) machines. In this paper, a hybrid analytical model suitable for the open-circuit field calculation of multilayer IPM machines is proposed by coupling the magnetic equivalent circuit (MEC) method and the subdomain technique. In the proposed analytical model, the rotor magnetic field is calculated by the MEC method based on the Kirchhoff's law, while the field in the stator slot, slot opening and air-gap is calculated by subdomain technique based on the Maxwell's equation. To solve the whole field distribution of the multilayer IPM machines, the coupled boundary conditions on the rotor surface are deduced for the coupling of the rotor MEC and the analytical field distribution of the stator slot, slot opening and air-gap. The hybrid analytical model can be used to calculate the open-circuit air-gap field distribution, back electromotive force (EMF) and cogging torque of multilayer IPM machines. Compared with finite element analysis (FEA), it has the advantages of faster modeling, less computation source occupying and shorter time consuming, and meanwhile achieves the approximate accuracy. The analytical model is helpful and applicable for the open-circuit field calculation of multilayer IPM machines with any size and pole/slot number combination.
Hydraulic actuator for an electric circuit breaker
Imam, I.
1983-05-17
This actuator comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit breaker opening operation. The breaker-opening space and the breaker-closing space are connected by an impeded flow passage. A pilot valve opens to allow the pressurized liquid in the breaker-closing space to flow to a back chamber of a normally closed main valve to cause the main valve to be opened during a circuit breaker opening operation to release the pressurized liquid from the breaker-closing space. An impeded passage affords communication between the back chamber and a sump located on the opposite side of the main valve from the back chamber. The pilot valve and impeded passage allow rapid opening of the main valve with pressurized liquid from the breaker closing side of the piston. 3 figs.
Hydraulic actuator for an electric circuit breaker
Imam, Imdad [Colonie, NY
1983-01-01
This actuator comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit breaker opening operation. The breaker-opening space and the breaker-closing space are connected by an impeded flow passage. A pilot valve opens to allow the pressurized liquid in the breaker-closing space to flow to a back chamber of a normally closed main valve to cause the main valve to be opened during a circuit breaker opening operation to release the pressurized liquid from the breaker-closing space. An impeded passage affords communication between the back chamber and a sump located on the opposite side of the main valve from the back chamber. The pilot valve and impeded passage allow rapid opening of the main valve with pressurized liquid from the breaker closing side of the piston.
2014-01-01
Background Spirometry is commonly accepted as the gold standard for the diagnosis of COPD, but the reality remains that quality assured spirometry is not or cannot be provided universally around the globe. Adding PEF measurement to a screening questionnaire may rule out airflow limitation compatible with COPD rationalizing spirometry testing. Methods We conducted a cross-sectional survey in a sample of individuals 40–80 yrs. old in Dubai, UAE. They were invited to answer a short socio-demographic questionnaire including a report on current, past history of smoking, and had PEF measured, then they conducted spirometry to identify airflow limitation compatible with COPD. Results Overall, 525 (91.0%) participants performed PEF and spirometry (68% male, with a mean age of 59 years, 17% UAE Nationals), 24% reported smoking of different sorts. Overall, 68 participants (12.9%, 95% C.I. 10.3% to 16.1%) had airflow limitation compatible with COPD. PEFR alone identified 141participants with airflow limitation compatible with COPD, with specificity of 80% and sensitivity of 73.5%. Conclusions PEFR could be an easy, cheap, and non-biased tool to assist with the case-finding of COPD before confirmation with spirometry. PMID:24739210
46 CFR 169.670 - Circuit breakers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Gross Tons § 169.670 Circuit breakers. Each circuit breaker must be of the manually reset type designed for— (a) Inverse time delay; (b) Instantaneous short circuit protection; and (c) Repeated opening of... 46 Shipping 7 2010-10-01 2010-10-01 false Circuit breakers. 169.670 Section 169.670 Shipping COAST...
30 CFR 18.51 - Electrical protection of circuits and equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the junction with the main circuit when the branch-circuit conductor(s) has a current carrying... same duty. (1) If the overcurrent-protective device in a direct-current circuit does not open both... preventing the possibility of reversing connections which would result in changing the circuit interrupter to...
30 CFR 18.51 - Electrical protection of circuits and equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the junction with the main circuit when the branch-circuit conductor(s) has a current carrying... same duty. (1) If the overcurrent-protective device in a direct-current circuit does not open both... preventing the possibility of reversing connections which would result in changing the circuit interrupter to...
The effect of medical clowns on performance of spirometry among preschool aged children.
Nir, Vered; Schichter-Konfino, Vered; Kassem, Eias; Klein, Adi
2018-04-02
Medical clowns (MCs) are known to assist in reducing pain and alleviating anxiety. The objective of this study is to evaluate the ability of MCs to assist preschoolers in performing spirometry. A prospective, randomized controlled trial. Children aged 3-6 years participated. After a first spirometry, children were divided into two groups: the first performed a second spirometry with an MC. The second repeated spirometry with the technician. Primary outcome was second spirometry values compared between the groups. Secondary outcome were change in spirometry values within groups, and difference between the groups. A total of 140 children participated. The groups did not differ in age, sex, mother tongue, or weight. Nor in mean FVC (MC 89.2% ± 16.7, control 89.5% ± 16.3) mean FEV1 (MC 91.3% ± 15.6, control 94.2% ± 16.8), and expiratory time (MC 1.58 ± 0.43, control 1.7 ± 0.44) in first spirometry. In second spirometry the control group had a similar FVC, FEV1, and expiratory time. The MC group had a significant improvement in all parameters: FVC: MC 95.3% ± 15.5, control 89.3% ± 19.1, FEV1: MC 98.0% ± 15.6, control 91.8% ± 19.3, and expiratory time MC 1.96 ± 0.55, control 1.84 ± 0.52. The differences between the groups between first and second attempt were significant (P-value FVC 0.000, FEV1 0.000, expiratory time 0.003). MCs improved performance of spirometry among preschoolers. It is possible that laughter and relief of stress had a physiological effect. Further studies are required to better establish the ability of MCs to improve active participation and to better understand whether the mechanism of the improvement is better cooperation or true physiological change. © 2018 Wiley Periodicals, Inc.
Postoperative incentive spirometry use.
Hassanzadeh, Hamid; Jain, Amit; Tan, Eric W; Stein, Benjamin E; Van Hoy, Megan L; Stewart, Nadine N; Lemma, Mesfin A
2012-06-01
The authors hypothesized that the use of incentive spirometry by orthopedic patients is less than the recommended level and is affected by patient-related factors and type of surgery. To determine its postoperative use, the authors prospectively surveyed all patients in their institution's general orthopedic ward who had undergone elective spine surgery or total knee or hip arthroplasty during a consecutive 3-month period in 2010, excluding patients with postoperative delirium or requiring a monitored bed. All 182 patients (74 men, 108 women; average age, 64.5 years; range, 32-88 years; spine group, n=55; arthroplasty group, n=127), per protocol, received preoperative spirometry education by a licensed respiratory therapist (recommended use, 10 times hourly) and reinforcement education by nurses. Patients were asked twice daily (morning and evening) regarding their spirometry use during the previous 1-hour period by a registered nurse on postoperative days 1 through 3. All data were collected by the same 2 nurses using the same standardized questionnaire. Spirometry use was correlated with surgery type, postoperative day/time, and patient's age and sex. Student's t test, Spearman test, and one-way analysis of variance were used to compare differences (P<.05). Spirometry use averaged 4.1 times per hour (range, 0-10 times). No statistical correlations were found between spirometry use and age. Sex did not influence spirometry use. The arthroplasty group reported significantly higher use than did the spine group: 4.3 and 3.5 times per hour, respectively. Mean use increased significantly between postoperative days 1, 2, and 3. Copyright 2012, SLACK Incorporated.
A high open-circuit voltage gallium nitride betavoltaic microbattery
NASA Astrophysics Data System (ADS)
Cheng, Zaijun; Chen, Xuyuan; San, Haisheng; Feng, Zhihong; Liu, Bo
2012-07-01
A high open-circuit voltage betavoltaic microbattery based on a gallium nitride (GaN) p-i-n homojunction is demonstrated. As a beta-absorbing layer, the low electron concentration of the n-type GaN layer is achieved by the process of Fe compensation doping. Under the irradiation of a planar solid 63Ni source with activity of 0.5 mCi, the open-circuit voltage of the fabricated microbattery with 2 × 2 mm2 area reaches as much as 1.64 V, which is the record value reported for betavoltaic batteries with 63Ni source, the short-circuit current was measured as 568 pA and the conversion effective of 0.98% was obtained. The experimental results suggest that GaN is a high-potential candidate for developing the betavoltaic microbattery.
Kundra, Pankaj; Vitheeswaran, Madhurima; Nagappa, Mahesh; Sistla, Sarath
2010-06-01
This study was designed to compare the effects of preoperative and postoperative incentive spirometry on lung functions after laparoscopic cholecystectomy in 50 otherwise normal healthy adults. Patients were randomized into a control group (group PO, n=25) and a study group (group PR, n=25). Patients in group PR were instructed to carry out incentive spirometry before the surgery 15 times, every fourth hourly, for 1 week whereas in group PO, incentive spirometry was carried out during the postoperative period. Lung functions were recorded at the time of preanesthetic evaluation, on the day before the surgery, postoperatively at 6, 24, and 48 hours, and at discharge. Significant improvement in the lung functions was seen after preoperative incentive spirometry (group PR), P<0.05. The lung functions were significantly reduced till the time of discharge in both the groups. However, lung functions were better preserved in group PR at all times when compared with group PO; P<0.05. To conclude, lung functions are better preserved with preoperative than postoperative incentive spirometry.
29 CFR 1910.401 - Scope and application.
Code of Federal Regulations, 2014 CFR
2014-07-01
... is using an open-circuit, semi-closed-circuit, or closed-circuit self-contained underwater breathing... death, serious physical harm, or major environmental damage, provided that the employer: (1) Notifies...
29 CFR 1910.401 - Scope and application.
Code of Federal Regulations, 2012 CFR
2012-07-01
... is using an open-circuit, semi-closed-circuit, or closed-circuit self-contained underwater breathing... death, serious physical harm, or major environmental damage, provided that the employer: (1) Notifies...
29 CFR 1910.401 - Scope and application.
Code of Federal Regulations, 2011 CFR
2011-07-01
... is using an open-circuit, semi-closed-circuit, or closed-circuit self-contained underwater breathing... death, serious physical harm, or major environmental damage, provided that the employer: (1) Notifies...
29 CFR 1910.401 - Scope and application.
Code of Federal Regulations, 2013 CFR
2013-07-01
... is using an open-circuit, semi-closed-circuit, or closed-circuit self-contained underwater breathing... death, serious physical harm, or major environmental damage, provided that the employer: (1) Notifies...
Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R
2014-10-30
Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity.
Luize, Ana P; Menezes, Ana Maria B; Perez-Padilla, Rogelio; Muiño, Adriana; López, Maria Victorina; Valdivia, Gonzalo; Lisboa, Carmem; Montes de Oca, Maria; Tálamo, Carlos; Celli, Bartolomé; Nascimento, Oliver A; Gazzotti, Mariana R; Jardim, José R
2014-01-01
Background: Spirometry is the gold standard for diagnosing chronic obstructive pulmonary disease (COPD). Although there are a number of different guideline criteria for deciding who should be selected for spirometric screening, to date it is not known which criteria are the best based on sensitivity and specificity. Aims: Firstly, to evaluate the proportion of subjects in the PLATINO Study that would be recommended for spirometry testing according to Global initiative for Obstructive Lung Disease (GOLD)-modified, American College of Chest Physicians (ACCP), National Lung Health Education Program (NLHEP), GOLD and American Thoracic Society/European Respiratory Society (ATS/ERS) criteria. Secondly, we aimed to compare the sensitivity, specificity, and positive predictive and negative predictive values, of these five different criteria. Methods: Data from the PLATINO study included information on respiratory symptoms, smoking and previous spirometry testing. The GOLD-modified spirometry indication criteria are based on three positive answers out of five questions: the presence of cough, phlegm in the morning, dyspnoea, age over 40 years and smoking status. Results: Data from 5,315 subjects were reviewed. Fewer people had an indication for spirometry (41.3%) according to the GOLD-modified criteria, and more people had an indication for spirometry (80.4%) by the GOLD and ATS/ERS criteria. A low percentage had previously had spirometry performed: GOLD-modified (14.5%); ACCP (13.2%); NLHEP (12.6%); and GOLD and ATS/ERS (12.3%). The GOLD-modified criteria showed the least sensitivity (54.9) and the highest specificity (61.0) for detecting COPD, whereas GOLD and ATS/ERS criteria showed the highest sensitivity (87.9) and the least specificity (20.8). Conclusion: There is a considerable difference in the indication for spirometry according to the five different guideline criteria. The GOLD-modified criteria recruit less people with the greatest sum of sensitivity and specificity. PMID:25358021
49 CFR 236.60 - Switch shunting circuit; use restricted.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and... circuit shall not be hereafter installed, except where tract or control circuit is opened by the circuit controller. [49 FR 3384, Jan. 26, 1984] Wires and Cables ...
49 CFR 236.60 - Switch shunting circuit; use restricted.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and... circuit shall not be hereafter installed, except where tract or control circuit is opened by the circuit controller. [49 FR 3384, Jan. 26, 1984] Wires and Cables ...
49 CFR 236.60 - Switch shunting circuit; use restricted.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and... circuit shall not be hereafter installed, except where tract or control circuit is opened by the circuit controller. [49 FR 3384, Jan. 26, 1984] Wires and Cables ...
49 CFR 236.60 - Switch shunting circuit; use restricted.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and... circuit shall not be hereafter installed, except where tract or control circuit is opened by the circuit controller. [49 FR 3384, Jan. 26, 1984] Wires and Cables ...
49 CFR 236.60 - Switch shunting circuit; use restricted.
Code of Federal Regulations, 2012 CFR
2012-10-01
..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and... circuit shall not be hereafter installed, except where tract or control circuit is opened by the circuit controller. [49 FR 3384, Jan. 26, 1984] Wires and Cables ...
49 CFR 236.732 - Controller, circuit; switch.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Controller, circuit; switch. 236.732 Section 236... § 236.732 Controller, circuit; switch. A device for opening and closing electric circuits, operated by a rod connected to a switch, derail or movable-point frog. ...
49 CFR 236.732 - Controller, circuit; switch.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Controller, circuit; switch. 236.732 Section 236... § 236.732 Controller, circuit; switch. A device for opening and closing electric circuits, operated by a rod connected to a switch, derail or movable-point frog. ...
49 CFR 236.732 - Controller, circuit; switch.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Controller, circuit; switch. 236.732 Section 236... § 236.732 Controller, circuit; switch. A device for opening and closing electric circuits, operated by a rod connected to a switch, derail or movable-point frog. ...
49 CFR 236.732 - Controller, circuit; switch.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Controller, circuit; switch. 236.732 Section 236... § 236.732 Controller, circuit; switch. A device for opening and closing electric circuits, operated by a rod connected to a switch, derail or movable-point frog. ...
49 CFR 236.732 - Controller, circuit; switch.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Controller, circuit; switch. 236.732 Section 236.732 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 236.732 Controller, circuit; switch. A device for opening and closing electric circuits, operated by a...
Hydraulically-activated operating system for an electric circuit breaker
Imam, Imdad; Barkan, Philip
1979-01-01
This operating system comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit-breaker opening operation. A normally-closed valve located on the breaker-closing-side of the piston is openable to release liquid from the breaker-closing space so that pressurized liquid in the breaker-opening space can drive the piston in an opening direction. Means is provided for restoring the valve to its closed position following the circuit-breaker opening operation. An impeded passage affords communication between the accumulator and the breaker-closing space to allow pressurized liquid to flow from the accumulator to the breaker-closing space and develop a pressure therein substantially equal to accumulator pressure when the valve is restored to closed position following breaker-opening. This passage is so impeded that the flow therethrough from the accumulator into the breaker-closing space is sufficiently low during initial opening motion of the piston through a substantial portion of its opening stroke as to avoid interference with said initial opening motion of the piston.
High speed hydraulically-actuated operating system for an electric circuit breaker
Iman, I.
1983-06-07
This hydraulically-actuated operating system comprises a cylinder, a piston movable therein in an opening direction to open a circuit breaker, and an accumulator for supplying pressurized liquid to a breaker-opening piston-actuating space within the cylinder. A normally-closed valve between the accumulator and the actuating space is openable to allow pressurized liquid from the accumulator to flow through the valve into the actuating space to drive the piston in an opening direction. A dashpotting mechanism operating separately from the hydraulic actuating system is provided, thereby reducing flow restriction interference with breaker opening. 3 figs.
High speed hydraulically-actuated operating system for an electric circuit breaker
Iman, Imdad
1983-06-07
This hydraulically-actuated operating system comprises a cylinder, a piston movable therein in an opening direction to open a circuit breaker, and an accumulator for supplying pressurized liquid to a breaker-opening piston-actuating space within the cylinder. A normally-closed valve between the accumulator and the actuating space is openable to allow pressurized liquid from the accumulator to flow through the valve into the actuating space to drive the piston in an opening direction. A dashpotting mechanism operating separately from the hydraulic actuating system is provided, thereby reducing flow restriction interference with breaker opening.
Diminishing detonator effectiveness through electromagnetic effects
Schill, Jr, Robert A.
2016-09-20
An inductively coupled transmission line with distributed electromotive force source and an alternative coupling model based on empirical data and theory were developed to initiate bridge wire melt for a detonator with an open and a short circuit detonator load. In the latter technique, the model was developed to exploit incomplete knowledge of the open circuited detonator using tendencies common to all of the open circuit loads examined. Military, commercial, and improvised detonators were examined and modeled. Nichrome, copper, platinum, and tungsten are the detonator specific bridge wire materials studied. The improvised detonators were made typically made with tungsten wire and copper (.about.40 AWG wire strands) wire.
Methods for improving solar cell open circuit voltage
Jordan, John F.; Singh, Vijay P.
1979-01-01
A method for producing a solar cell having an increased open circuit voltage. A layer of cadmium sulfide (CdS) produced by a chemical spray technique and having residual chlorides is exposed to a flow of hydrogen sulfide (H.sub.2 S) heated to a temperature of 400.degree.-600.degree. C. The residual chlorides are reduced and any remaining CdCl.sub.2 is converted to CdS. A heterojunction is formed over the CdS and electrodes are formed. Application of chromium as the positive electrode results in a further increase in the open circuit voltage available from the H.sub.2 S-treated solar cell.
Feasibility of spirometry in primary care to screen for COPD: a pilot study
Giraud, Violaine; Beauchet, Alain; Gomis, Thierry; Chinet, Thierry
2016-01-01
Background COPD is a frequent but underdiagnosed disease whose diagnosis relies on the spirometric demonstration of bronchial obstruction. Spirometry use by general practitioners could represent the first line in COPD diagnosis. Objective Because duration of spirometry is retarding its development in primary care, we decided to measure the time it requires in the primary-care context in France. Methods Ten volunteer general practitioners were trained during two 3-hour theoretical and practical continuing education sessions. Then, from October 2013 to May 2014, they included patients without any known respiratory disease but at risk of developing COPD (age: ≥40 years, smoker: ≥20 pack-years). The duration of spirometry and its quality were evaluated according to the following acceptability criteria: 1) expiration ≥6 seconds or reaching a plateau; 2) good start with an early peak flow, curve peaked on top and not flat; 3) no artifacts; and 4) reproducibility criteria, ie, forced expiratory volume in 1 second and forced vital capacity differences between the two best spirometry curves ≤0.15 L. Quality of the spirograms was defined as optimal when all the criteria were met and acceptable when all the criteria were satisfied except the reproducibility criterion, otherwise, it was unacceptable. Results For the 152 patients included, the 142 assessable spirometries lasted for 15.2±5.9 minutes. Acceptability criteria 1–3, respectively, were satisfied for 90.1%, 89.4%, and 91.5% of patients and reproducibility criterion 4 for 56.3%. Quality was considered optimal for 58.5% of the curves and acceptable for 30.2%. Conclusion The duration of spirometry renders it poorly compatible with the current primary-care practice in France other than for dedicated consultations. Moreover, the quality of spirometry needs to be improved. PMID:26929617
Yu, Wai Cho; Fu, Sau Nga; Tai, Emily Lai-bun; Yeung, Yiu Cheong; Kwong, Kwok Chu; Chang, Yui; Tam, Cheuk Ming; Yiu, Yuk Kwan
2013-01-01
Spirometry is important in the diagnosis and management of chronic obstructive pulmonary disease (COPD), yet it is a common clinical observation that it is underused though the extent is unclear. This survey aims to examine the use of spirometry in the diagnosis and management of COPD patients in a district in Hong Kong. It is a cross-sectional survey involving four clinic settings: hospital-based respiratory specialist clinic, hospital-based mixed medical specialist clinic, general outpatient clinic (primary care), and tuberculosis and chest clinic. Thirty physician-diagnosed COPD patients were randomly selected from each of the four clinic groups. All of them had a forced expiratory volume in 1 second (FEV1) to forced vital capacity ratio less than 0.70 and had been followed up at the participating clinic for at least 6 months for COPD treatment. Of 126 patients who underwent spirometry, six (4.8%) did not have COPD. Of the 120 COPD patients, there were 111 males and mean post-bronchodilator FEV1 was 46.2% predicted. Only 22 patients (18.3%) had spirometry done during diagnostic workup, and 64 patients (53.3%) had spirometry done ever. The only independent factor predicting spirometry done ever was absence of old pulmonary tuberculosis and follow-up at respiratory specialist clinic. Age, sex, smoking status, comorbidities, duration of COPD, percentage predicted FEV1, body mass index, 6-minute walking distance, and Medical Research Council dyspnea score were not predictive. We conclude that spirometry is underused in general but especially by nonrespiratory physicians and family physicians in the management of COPD patients. More effort at educating the medical community is urgently needed. PMID:24009418
Reference values of inspiratory spirometry for Finnish adults.
Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R
2018-03-07
Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.
Eliseev, Eugene A.; Kalinin, Sergei V.; Morozovska, Anna N.
2015-01-21
General features of finite size effects in the ferroelectric-semiconductor film under open-circuit electric boundary conditions are analyzed using Landau-Ginzburg-Devonshire theory and continuum media electrostatics. The temperature dependence of the film critical thickness, spontaneous polarization and depolarization field profiles of the open-circuited films are found to be significantly different from the characteristics of short-circuited ones. In particular, we predict the re-entrant type transition boundary between the mono-domain and poly-domain ferroelectric states due to reduced internal screening efficiency and analyzed possible experimental scenarios created by this mechanism. Performed analysis is relevant for the quantitative description of free-standing ferroelectric films phase diagrams andmore » polar properties. Also our results can be useful for the explanation of the scanning-probe microscopy experiments on free ferroelectric surfaces.« less
Laser beam apparatus and method for analyzing solar cells
Staebler, David L.
1980-01-01
A laser beam apparatus and method for analyzing, inter alia, the current versus voltage curve at the point of illumination on a solar cell and the open circuit voltage of a solar cell. The apparatus incorporates a lock-in amplifier, and a laser beam light chopper which permits the measurement of the AC current of the solar cell at an applied DC voltage at the position on the solar cell where the cell is illuminated and a feedback scheme which permits the direct scanning measurements of the open circuit voltage. The accuracy of the measurement is a function of the intensity and wavelength of the laser light with respect to the intensity and wavelength distribution of sunlight and the percentage the dark current is at the open circuit voltage to the short circuit current of the solar cell.
Molecular-Beam-Epitaxy Program
NASA Technical Reports Server (NTRS)
Sparks, Patricia D.
1988-01-01
Molecular Beam Epitaxy (MBE) computer program developed to aid in design of single- and double-junction cascade cells made of silicon. Cascade cell has efficiency 1 or 2 percent higher than single cell, with twice the open-circuit voltage. Input parameters include doping density, diffusion lengths, thicknesses of regions, solar spectrum, absorption coefficients of silicon (data included for 101 wavelengths), and surface recombination velocities. Results include maximum power, short-circuit current, and open-circuit voltage. Program written in FORTRAN IV.
Okandan, Murat; Nielson, Gregory N
2014-12-09
Accessing a workpiece object in semiconductor processing is disclosed. The workpiece object includes a mechanical support substrate, a release layer over the mechanical support substrate, and an integrated circuit substrate coupled over the release layer. The integrated circuit substrate includes a device layer having semiconductor devices. The method also includes etching through-substrate via (TSV) openings through the integrated circuit substrate that have buried ends at or within the release layer including using the release layer as an etch stop. TSVs are formed by introducing one or more conductive materials into the TSV openings. A die singulation trench is etched at least substantially through the integrated circuit substrate around a perimeter of an integrated circuit die. The integrated circuit die is at least substantially released from the mechanical support substrate.
Elements configuration of the open lead test circuit
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fukuzaki, Yumi, E-mail: 14514@sr.kagawa-nct.ac.jp; Ono, Akira
In the field of electronics, small electronic devices are widely utilized because they are easy to carry. The devices have various functions by user’s request. Therefore, the lead’s pitch or the ball’s pitch have been narrowed and high-density printed circuit board has been used in the devices. Use of the ICs which have narrow lead pitch makes normal connection difficult. When logic circuits in the devices are fabricated with the state-of-the-art technology, some faults have occurred more frequently. It can be divided into types of open faults and short faults. We have proposed a new test method using a testmore » circuit in the past. This paper propose elements configuration of the test circuit.« less
2008-04-01
New U.S. Preventive Services Task Force (USPSTF) recommendation about screening for chronic obstructive pulmonary disease (COPD) using spirometry. The USPSTF weighed the benefits (prevention of > or =1 exacerbation and improvement in respiratory-related health status measures) and harms (time and effort required by both patients and the health care system, false-positive screening tests, and adverse effects of subsequent unnecessary therapy) of COPD screening identified in the accompanying review of the evidence. The USPSTF did not consider the financial costs of spirometry testing or COPD therapies. Do not screen adults for COPD using spirometry. (Grade D recommendation).
47 CFR 78.51 - Remote control operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... necessary to insure proper operation. (4) The control circuits shall be so designed and installed that short circuits, open circuits, other line faults, or any other cause which would result in loss of control of the...
49 CFR 236.342 - Switch circuit controller.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Switch circuit controller. 236.342 Section 236.342... Instructions § 236.342 Switch circuit controller. Switch circuit controller connected at the point to switch... corresponding to switch point closure when switch point is open one-fourth inch or more. Inspection and Tests ...
49 CFR 236.342 - Switch circuit controller.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Switch circuit controller. 236.342 Section 236.342... Instructions § 236.342 Switch circuit controller. Switch circuit controller connected at the point to switch... corresponding to switch point closure when switch point is open one-fourth inch or more. Inspection and Tests ...
49 CFR 236.342 - Switch circuit controller.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Switch circuit controller. 236.342 Section 236.342... Instructions § 236.342 Switch circuit controller. Switch circuit controller connected at the point to switch... corresponding to switch point closure when switch point is open one-fourth inch or more. Inspection and Tests ...
49 CFR 236.342 - Switch circuit controller.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Switch circuit controller. 236.342 Section 236.342... Instructions § 236.342 Switch circuit controller. Switch circuit controller connected at the point to switch... corresponding to switch point closure when switch point is open one-fourth inch or more. Inspection and Tests ...
49 CFR 236.342 - Switch circuit controller.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Switch circuit controller. 236.342 Section 236.342... Instructions § 236.342 Switch circuit controller. Switch circuit controller connected at the point to switch... corresponding to switch point closure when switch point is open one-fourth inch or more. Inspection and Tests ...
Dynamically Movable Exhausting Emc Sealing System
Barringer, Dennis R.; Seminaro, Edward J.; Toffler, Harold M.
2003-12-09
A docking apparatus for printed circuit boards including a cassette housing, having a housing base, a housing cover and a housing wall, wherein the housing base and the housing wall are disposed relative to each other so as to define a housing cavity for containing a printed circuit card and wherein the housing wall includes a cable opening disposed so as to be communicated with the housing cavity, a housing bezel, disposed relative to the cassette housing so as to be associated with the cable opening, the housing bezel includes an outer bezel having a first plurality of openings and an inner bezel having a second plurality of apertures, the inner bezel in electrical communication with the printed circuit card, wherein said housing bezel is removable, and an EMC gasket disposed between the outer and inner bezels of said housing bezel, the EMC gasket configured to provide a removable EMC seal proximate the cable opening while still allowing airflow through the first and second plurality of apertures having the EMC gasket therebetween. A docking apparatus for printed circuit boards including a cassette housing, having a housing base, a housing cover and a housing wall, wherein the housing base and the housing wall are disposed relative to each other so as to define a housing cavity for containing a printed circuit card and wherein the housing wall includes a cable opening disposed so as to be communicated with the housing cavity, a housing bezel, disposed relative to the cassette housing so as to be associated with the cable opening, the housing bezel includes an outer bezel having a first plurality of openings and an inner bezel having a second plurality of apertures, the inner bezel in electrical communication with the printed circuit card, wherein said housing bezel is removable, and an EMC gasket disposed between the outer and inner bezels of said housing bezel, the EMC gasket configured to provide a removable EMC seal proximate the cable opening while still allowing airflow through the first and second plurality of apertures having the EMC gasket therebetween.
Optimization of the Switch Mechanism in a Circuit Breaker Using MBD Based Simulation
Jang, Jin-Seok; Yoon, Chang-Gyu; Ryu, Chi-Young; Kim, Hyun-Woo; Bae, Byung-Tae; Yoo, Wan-Suk
2015-01-01
A circuit breaker is widely used to protect electric power system from fault currents or system errors; in particular, the opening mechanism in a circuit breaker is important to protect current overflow in the electric system. In this paper, multibody dynamic model of a circuit breaker including switch mechanism was developed including the electromagnetic actuator system. Since the opening mechanism operates sequentially, optimization of the switch mechanism was carried out to improve the current breaking time. In the optimization process, design parameters were selected from length and shape of each latch, which changes pivot points of bearings to shorten the breaking time. To validate optimization results, computational results were compared to physical tests with a high speed camera. Opening time of the optimized mechanism was decreased by 2.3 ms, which was proved by experiments. Switch mechanism design process can be improved including contact-latch system by using this process. PMID:25918740
Derivation of the open-circuit voltage of organic solar cells
NASA Astrophysics Data System (ADS)
Staple, Douglas B.; Oliver, Patricia A. K.; Hill, Ian G.
2014-05-01
Organic photovoltaic cells have improved in efficiency from 1% two decades ago to over 10% today. Continued improvement necessitates a theoretical understanding of the factors determining efficiency. Organic photovoltaic efficiency can be parameterized in terms of open-circuit voltage, short-circuit current, and fill factor. Here we present a theory that explains the dependencies of open-circuit voltage on semiconductor energy levels, light intensity, solar cell and light-source temperatures, charge-carrier recombination, and external fluorescence efficiency. The present theory also explains why recombination at the donor-acceptor heterointerface is a dominant process in heterojunction-based cells. Furthermore, the Carnot efficiency appears, highlighting the connection to basic thermodynamics. The theory presented here is consistent with and builds on the experimental and theoretical observations already in the literature. Crucially, the present theory can be straightforwardly derived in a line-by-line fashion using standard tools from statistical physics.
Bender, M.; Bennett, F.K.; Kuckes, A.F.
1963-09-17
A fast-acting electric switch is described for rapidly opening a circuit carrying large amounts of electrical power. A thin, conducting foil bridges a gap in this circuit and means are provided for producing a magnetic field and eddy currents in the foil, whereby the foil is rapidly broken to open the circuit across the gap. Advantageously the foil has a hole forming two narrow portions in the foil and the means producing the magnetic field and eddy currents comprises an annular coil having its annulus coaxial with the hole in the foil and turns adjacent the narrow portions of the foil. An electrical current flows through the coil to produce the magnetic field and eddy currents in the foil. (AEC)
Matlab-Excel Interface for OpenDSS
DOE Office of Scientific and Technical Information (OSTI.GOV)
The software allows users of the OpenDSS grid modeling software to access their load flow models using a GUI interface developed in MATLAB. The circuit definitions are entered into a Microsoft Excel spreadsheet which makes circuit creation and editing a much simpler process than the basic text-based editors used in the native OpenDSS interface. Plot tools have been developed which can be accessed through a MATLAB GUI once the desired parameters have been simulated.
Xu, Chun; Chao, Yong-lie; Du, Li; Yang, Ling
2004-05-01
To measure and analyze the flux densities of static magnetic fields generated by two types of commonly used dental magnetic attachments and their retentive forces, and to provide guidance for the clinical application of magnetic attachments. A digital Gaussmeter was used to measure the flux densities of static magnetic fields generated by two types of magnetic attachments, under four circumstances: open-field circuit; closed-field circuit; keeper and magnet slid laterally for a certain distance; and existence of air gap between keeper and magnet. The retentive forces of the magnetic attachments in standard closed-field circuit, with the keeper and magnet sliding laterally for a certain distance or with a certain air gap between keeper and magnet were measured by a tensile testing machine. There were flux leakages under both the open-field circuit and closed-field circuit of the two types of magnetic attachments. The flux densities on the surfaces of MAGNEDISC 800 (MD800) and MAGFIT EX600W (EX600) magnetic attachments under open-field circuit were 275.0 mT and 147.0 mT respectively. The flux leakages under closed-field circuit were smaller than those under open-field circuit. The respective flux densities on the surfaces of MD800 and EX600 magnetic attachments decreased to 11.4 mT and 4.5 mT under closed-field circuit. The flux density around the magnetic attachment decreased as the distance from the surface of the attachment increased. When keeper and magnet slid laterally for a certain distance or when air gap existed between keeper and magnet, the flux leakage increased in comparison with that under closed-field circuit. Under the standard closed-field circuit, the two types of magnetic attachments achieved the largest retentive forces. The retentive forces of MD800 and EX600 magnetic attachments under the standard closed-field circuit were 6.20 N and 4.80 N respectively. The retentive forces decreased with the sliding distance or with the increase of air gap between keeper and magnet. The magnetic attachments have flux leakages. When they are used in patients' oral cavities, if keeper and magnet are not attached accurately, the flux leakage will increase, and at the same time the retentive force will decrease. Therefore the keeper and magnet should be attached accurately in clinical application.
Public spirometry for primary prevention of COPD.
Zirlik, Sabine; Wich, Christina; Frieser, Markus; Hildner, Kai; Kleye, Christin; Neurath, Markus F; Fuchs, Florian S
2014-02-01
The most effective action for primary prevention of chronic obstructive lung disease is smoking cessation early enough. In secondary prevention, smokers with airway obstruction were more likely to quit smoking. The aim of this study was to evaluate the impact of a public spirometry on smoking habits in terms of primary prevention. Spirometry with its medical analysis was offered to visitors of a local public event called 'Lange Nacht der Wissenschaften' ('Long night of sciences'). The impact of results on smoking habits was evaluated in all smokers with an anonymized questionnaire afterwards. Two hundred fifty-seven people with the median age of 30 years (interquartile range 22-46) were examined. Out of 44 current smokers (17.1%), only two individuals showed a prebronchodilator FEV1/forced vital capacity-value <0.7. Fourteen smokers stated to have an increased motivation to quit smoking whereas 28 smokers declared that their motivation to quit smoking was independent of spirometry result. These smokers were significantly younger (median age 28 vs. 40 years, P = 0.025) without differences in spirometry results or smoking habits. In an unselected population with a high amount of younger adults, normal spirometry did not show a short-term benefit for primary prevention of chronic obstructive lung disease in terms of increasing motivation to quit smoking. © 2013 John Wiley & Sons, Ltd.
Oscillometry complements spirometry in evaluation of subjects following toxic inhalation
Berger, Kenneth I.; Turetz, Meredith; Liu, Mengling; Shao, Yongzhao; Kazeros, Angeliki; Parsia, Sam; Caplan-Shaw, Caralee; Friedman, Stephen M.; Maslow, Carey B.; Marmor, Michael; Goldring, Roberta M.
2015-01-01
The World Trade Center (WTC) destruction released dust and fumes into the environment. Although many community members developed respiratory symptoms, screening spirometry was usually normal. We hypothesised that forced oscillation testing would identify functional abnormalities undetected by spirometry and that symptom severity would relate to magnitude of abnormalities measured by oscillometry. A symptomatic cohort (n=848) from the Bellevue Hospital WTC Environmental Health Center was evaluated and compared to an asymptomatic cohort (n=475) from the New York City Department of Health WTC Health Registry. Spirometry and oscillometry were performed. Oscillometry measurements included resistance (R5) and frequency dependence of resistance (R5−20). Spirometry was normal for the majority of subjects (73.2% symptomatic versus 87.6% asymptomatic, p<0.0001). In subjects with normal spirometry, R5 and R5−20 were higher in symptomatic versus asymptomatic subjects (median (interquartile range) R5 0.436 (0.206) versus 0.314 (0.129) kPa·L−1·s−1, p<0.001; R5−20 0.075 (0.085) versus 0.004 (0.042) kPa·L−1·s−1, p<0.0001). In symptomatic subjects, R5 and R5−20 increased with increasing severity and frequency of wheeze (p<0.05). Measurement of R5–20 correlated with the presence and severity of symptoms even when spirometry was within normal limits. These findings are in accord with small airway abnormalities as a potential explanation of the respiratory symptoms. PMID:27730155
Szylińska, Aleksandra; Listewnik, Mariusz J; Rotter, Iwona; Rył, Aleksandra; Biskupski, Andrzej; Brykczyński, Mirosław
2017-01-01
Background Preoperative spirometry provides measurable information about the occurrence of respiratory disorders. The aim of this study was to assess the association between preoperative spirometry abnormalities and the intensification of early inflammatory responses in patients following coronary artery bypass graft in extracorporeal circulation. Material and methods The study involved 810 patients (625 men and 185 women) aged 65.4±7.9 years who were awaiting isolated coronary artery bypass surgery. On the basis of spirometry performed on the day of admittance to the hospital, the patients were divided into three groups. Patients without respiratory problems constituted 78.8% of the entire group. Restricted breathing was revealed by spirometry in 14.9% and obstructive breathing in 6.3% of patients. Results Inter-group analysis showed statistically significant differences in C-reactive protein (CRP) between patients with restrictive spirometry abnormalities and patients without any pulmonary dysfunction. CRP concentrations differed before surgery (P=0.006) and on the second (P<0.001), fourth (P=0.005) and sixth days after surgery (P=0.029). There was a negative correlation between CRP levels and FEV1. Conclusion In our study, the most common pulmonary disorders in the coronary artery bypass graft patients were restrictive. Patients with abnormal spirometry results from restrictive respiratory disorders have an elevated level of generalized inflammatory response both before and after the isolated coronary artery bypass surgery. Therefore, this group of patients should be given special postoperative monitoring and, in particular, intensive respiratory rehabilitation immediately after reconstitution. PMID:28769557
Labrecque, M; Lavallée, M; Beauchesne, MF; Cartier, A; Boulet, LP
2006-01-01
BACKGROUND AND OBJECTIVES: Asthma remains uncontrolled in a large number of asthmatic patients. Recent surveys have shown that a minority of asthmatic patients are referred to asthma educators. The objective of the present study was to assess the influence of increased access to spirometry in asthma education centres (AECs) on the rate of patient referrals to these centres by general practitioners. METHODS: A one-year, prospective, randomized, multicentric, parallel group study was conducted over two consecutive periods of six months each, with added spirometry being offered in the second six-month period to the experimental group. Ten AECs were enrolled in the project. An advertisement describing the AECs’ services was sent by mail to a total of 303 general practitioners at the start of each period, inviting them to refer their patients. Measures of the frequency of medical referrals to the AECs were assessed for each period. RESULTS: The group of AECs randomly selected for spirometry in the second six-month period received 48 medical referrals during the first period and 32 during the second one, following proposed spirometry. AECs that had not offered spirometry received five referrals during the first period and seven during the second period. One AEC withdrew a few weeks after the study began and others encountered administrative problems, reducing their ability to provide interventions. CONCLUSIONS: Referral to AECs is not yet integrated into the primary care of asthma and offering more rapid access to spirometry in the AECs does not seem to be a significant incentive for such referrals. PMID:17149461
Labrecque, M; Lavallée, M; Beauchesne, M F; Cartier, A; Boulet, L P
2006-01-01
Asthma remains uncontrolled in a large number of asthmatic patients. Recent surveys have shown that a minority of asthmatic patients are referred to asthma educators. The objective of the present study was to assess the influence of increased access to spirometry in asthma education centres (AECs) on the rate of patient referrals to these centres by general practitioners. A one-year, prospective, randomized, multicentric, parallel group study was conducted over two consecutive periods of six months each, with added spirometry being offered in the second six-month period to the experimental group. Ten AECs were enrolled in the project. An advertisement describing the AECs' services was sent by mail to a total of 303 general practitioners at the start of each period, inviting them to refer their patients. Measures of the frequency of medical referrals to the AECs were assessed for each period. The group of AECs randomly selected for spirometry in the second six-month period received 48 medical referrals during the first period and 32 during the second one, following proposed spirometry. AECs that had not offered spirometry received five referrals during the first period and seven during the second period. One AEC withdrew a few weeks after the study began and others encountered administrative problems, reducing their ability to provide interventions. Referral to AECs is not yet integrated into the primary care of asthma and offering more rapid access to spirometry in the AECs does not seem to be a significant incentive for such referrals.
COPD case finding by spirometry in high-risk customers of urban community pharmacies: a pilot study.
Castillo, D; Guayta, R; Giner, J; Burgos, F; Capdevila, C; Soriano, J B; Barau, M; Casan, P
2009-06-01
COPD case finding is currently recommended at primary and tertiary care levels only. To evaluate the feasibility of a community pharmacy program for COPD case finding in high-risk customers by means of spirometry. Pilot cross-sectional descriptive study in 13 urban community pharmacies in Barcelona, Spain, from April to May 2007. Customers >40 years old with respiratory symptoms and/or a history of smoking were invited to participate in the study during pharmacists' routine work shifts. High-risk customers were identified by means of a 5-item COPD screening questionnaire based on criteria of the Global Initiative for Chronic Obstructive Lung Disease, and were invited to perform spirometry accordingly. Those with an FEV(1)/FVC ratio less than 0.70 were referred to the hospital for a repeat spirometry. Of the 161 pharmacy customers studied, 100 (62%) scored 3 or more items in the COPD screening questionnaire, and after spirometry, 21 (24%) had an FEV(1)/FVC ratio<0.7. When these subjects with airflow limitation were offered referral to a hospital respiratory function laboratory for further assessments, 11 (52%) attended the appointment. Over 70% of spirometries were rated as being of acceptable quality. No significant differences were observed in lung function parameters between the pharmacy and hospital measurements. COPD case finding by spirometry in high-risk customers of urban community pharmacies is feasible. Similarly to primary care practitioners, pharmacists have access to high-risk, middle-aged subjects who have never been tested for COPD. Pharmacists can help with early detection of COPD if they are correctly trained.
Goodman, G S; Tobey, A E; Batterman-Faunce, J M; Orcutt, H; Thomas, S; Shapiro, C; Sachsenmaier, T
1998-04-01
The present study was designed to examine effects of closed-circuit technology on children's testimony and jurors' perceptions of child witnesses. For the study, a series of elaborately staged mock trials was held. First, 5- to 6-year-old and 8- to 9-year-old children individually participated in a play session with an unfamiliar male confederate. Approximately 2 weeks later, children individually testified about the event at downtown city courtroom. Mock juries composed of community recruits viewed the trials, with the child's testimony presented either live in open court or over closed-circuit television. Mock jurors made ratings concerning the child witness and the defendant, and deliberated to reach a verdict. Results indicated that overall, older children were more accurate witnesses than younger children. However, older, not younger children produced more inaccurate information in free recall. Compared to live testimony in open court, use of closed-circuit technology led to decreased suggestibility for younger children. Testifying in open court was also associated with children experiencing greater pretrial anxiety. Closed-circuit technology did not diminish fact finders' abilities to discriminate accurate from inaccurate child testimony, nor did it directly bias jurors against the defendant. However, closed-circuit testimony biased jurors against child witnesses. Moreover, jurors tended to base their impressions of witness credibility on perceived confidence and consistency. Implications for the use of closed-circuit technology when children testify are discussed.
Incentive spirometry for preventing pulmonary complications after coronary artery bypass graft.
Freitas, E R F S; Soares, B G O; Cardoso, J R; Atallah, A N
2007-07-18
Following coronary artery bypass graft (CABG), the main causes of postoperative morbidity and mortality are postoperative pulmonary complications, respiratory dysfunction and arterial hypoxemia. Incentive spirometry is a treatment technique that uses a mechanical device (an incentive spirometer) to reduce such pulmonary complications during postoperative care. To assess the effects of incentive spirometry for preventing postoperative pulmonary complications in adults undergoing CABG. We searched CENTRAL on The Cochrane Library (Issue 2, 2004), MEDLINE (1966 to December 2004), EMBASE (1980 to December 2004), LILACS (1982 to December 2004), the Physiotherapy Evidence Database (PEDro) (1980 to December 2004), Allied & Complementary Medicine (AMED) (1985 to December 2004), CINAHL (1982 to December 2004), and the Database of Abstracts of Reviews of Effects (DARE) (1994 to December 2004). References were checked and authors contacted. No language restrictions were applied. Randomized controlled trials comparing incentive spirometry with any type of prophylactic physiotherapy for prevention of postoperative pulmonary complications in adults undergoing CABG. Two reviewers independently evaluated the quality of trials using the guidelines of the Cochrane Reviewers' Handbook and extracted data from included trials. Four trials with 443 participants contributed to this review. There was no significant difference in pulmonary complications (atelectasis and pneumonia) between treatment with incentive spirometry and treatment with positive pressure breathing techniques (continuous positive airway pressure (CPAP), bilevel positive airway pressure (BiPAP) and intermittent positive pressure breathing (IPPB)) or preoperative patient education. Patients treated with incentive spirometry had worse pulmonary function and arterial oxygenation compared with positive pressure breathing (CPAP, BiPAP, IPPB). Individual small trials suggest that there is no evidence of benefit from incentive spirometry in reducing pulmonary complications and in decreasing the negative effects on pulmonary function in patients undergoing CABG. In view of the modest number of patients studied, methodological shortcomings and poor reporting of the included trials, these results should be interpreted cautiously. An appropriately powered trial of high methodological rigour is needed to determine those patients who may derive benefit from incentive spirometry following CABG.
Embling, Laura A K; Zagami, Debbie; Sriram, Krishna Bajee; Gordon, Robert J; Sivakumaran, Pathmanathan
2016-12-01
The categorisation of lung disease into obstructive ventilatory defect (OVD) and tendency to a restrictive ventilatory defect (TRVD) patterns using spirometry is used to guide both prognostication and treatment. The effectiveness of categorisation depends upon having reference ranges that accurately represent the population they describe. The Global Lung Initiative 2012 (GLI 2012) has spirometry reference ranges drawn from the largest sample size to date. This study aimed to determine whether using spirometry reference ranges from the new GLI 2012 dataset, compared to the previously used National Health and Nutritional Examination Survey III (NHANES III) dataset, resulted in a change in diagnosis between OVD, TRVD and normal ventilatory pattern (NVP). Spirometry data were collected from 301 patients, aged 18-80 years, undergoing investigation at the Gold Coast Hospital and Health Service (GCHHS) throughout February and March 2014. OVD was defined as a forced expiratory volume in 1 second (FEV 1 ) divided by forced vital capacity (FVC) less than lower limit of normal (LLN). TRVD was defined as FEV 1 /FVC ≥ LLN, FEV 1 < LLN, and FVC < LLN. The LLN values were determined by equations from the GLI and NHANES datasets. Spirometry interpreted using the NHANES III equations showed: 102 individuals (33.9%) with normal spirometry, 136 (45.2%) with an OVD pattern, 52 (17.3%) with a TRVD pattern, and 11 (3.7%) with a mixed pattern. When the spirometry data were interpreted using the GLI 2012 equations 2 (0.7%) individuals changed from OVD to NVP, 2 (0.7%) changed from NVP to OVD and 14 (4.7%) changed from TRVD to NVP. Using the GLI 2012 reference range resulted in a change in diagnosis of lung disease in 5.9% of the individuals included in this study. This variance in diagnosis when changing reference ranges should be taken into account by clinicians as it may affect patient management.
... the bronchodilator improved your airflow. Results Key spirometry measurements include the following: Forced vital capacity (FVC). This is the largest amount of air that you can forcefully exhale after breathing in ...
Coates, Allan L; Graham, Brian L; McFadden, Robin G; McParland, Colm; Moosa, Dilshad; Provencher, Steeve; Road, Jeremy
2013-01-01
Canadian Thoracic Society (CTS) clinical guidelines for asthma and chronic obstructive pulmonary disease (COPD) specify that spirometry should be used to diagnose these diseases. Given the burden of asthma and COPD, most people with these diseases will be diagnosed in the primary care setting. The present CTS position statement was developed to provide guidance on key factors affecting the quality of spirometry testing in the primary care setting. The present statement may also be used to inform and guide the accreditation process for spirometry in each province. Although many of the principles discussed are equally applicable to pulmonary function laboratories and interpretation of tests by respirologists, they are held to a higher standard and are outside the scope of the present statement. PMID:23457669
Choi, Hyekyoung; Song, Jung Hoon; Jang, Jihoon; Mai, Xuan Dung; Kim, Sungwoo; Jeong, Sohee
2015-11-07
We fabricated heterojunction solar cells with PbSe/PbS core shell quantum dots and studied the precisely controlled PbS shell thickness dependency in terms of optical properties, electronic structure, and solar cell performances. When the PbS shell thickness increases, the short circuit current density (JSC) increases from 6.4 to 11.8 mA cm(-2) and the fill factor (FF) enhances from 30 to 49% while the open circuit voltage (VOC) remains unchanged at 0.46 V even with the decreased effective band gap. We found that the Fermi level and the valence band maximum level remain unchanged in both the PbSe core and PbSe/PbS core/shell with a less than 1 nm thick PbS shell as probed via ultraviolet photoelectron spectroscopy (UPS). The PbS shell reduces their surface trap density as confirmed by relative quantum yield measurements. Consequently, PbS shell formation on the PbSe core mitigates the trade-off relationship between the open circuit voltage and the short circuit current density. Finally, under the optimized conditions, the PbSe core with a 0.9 nm thick shell yielded a power conversion efficiency of 6.5% under AM 1.5.
A New Method for Raising Opening Velocity of Electromagnetic Actuated Vacuum Circuit Breaker
NASA Astrophysics Data System (ADS)
Tsukima, Mitsuru; Takeuchi, Toshie; Koyama, Kenichi; Yoshiyasu, Hajimu
Recently an electromagnetic actuator has been widely used as an operating mechanism for the vacuum circuit breaker (VCB). The opening velocity of the contact is supposed to be strongly related with current interruption performance. This paper presents a simple and new technique that raises opening velocity of the electromagnetic actuated VCB. In order to investigate this reason, we built a numerical simulator that predicts the dynamic characteristics of the VCB contact. It takes into account of the magnetic behavior in the actuator and is also coupled with the external control circuit. According to this simulation, it is shown that it is originated from the sharp rise in the electromagnetic thrust force due to the selective saturation of the magnetic yoke. As the result of our experiments, by this technique the opening velocity was verified to be 1.5 times faster than by the conventional way.
Protective Socket For Integrated Circuits
NASA Technical Reports Server (NTRS)
Wilkinson, Chris; Henegar, Greg
1988-01-01
Socket for intergrated circuits (IC's) protects from excessive voltages and currents or from application of voltages and currents in wrong sequence during insertion or removal. Contains built-in switch that opens as IC removed, disconnecting leads from signals and power. Also protects other components on circuit board from transients produced by insertion and removal of IC. Makes unnecessary to turn off power to entire circuit board so other circuits on board continue to function.
Resonant-tunnelling diode oscillator using a slot-coupled quasioptical open resonator
NASA Technical Reports Server (NTRS)
Stephan, K. D.; Brown, E. R.; Parker, C. D.; Goodhue, W. D.; Chen, C. L.
1991-01-01
A resonant-tunneling diode has oscillated at X-band frequencies in a microwave circuit consisting of a slot antenna coupled to a semiconfocal open resonator. Coupling between the open resonator and the slot oscillator improves the noise-to-carrier ratio by about 36 dB relative to that of the slot oscillator alone in the 100-200 kHz range. A circuit operating near 10 GHz has been designed as a scale model for millimeter- and submillimeter-wave applications.
Adjustable direct current and pulsed circuit fault current limiter
Boenig, Heinrich J.; Schillig, Josef B.
2003-09-23
A fault current limiting system for direct current circuits and for pulsed power circuit. In the circuits, a current source biases a diode that is in series with the circuits' transmission line. If fault current in a circuit exceeds current from the current source biasing the diode open, the diode will cease conducting and route the fault current through the current source and an inductor. This limits the rate of rise and the peak value of the fault current.
Daily Home Spirometry: An Effective Tool for Detecting Progression in Idiopathic Pulmonary Fibrosis
Russell, Anne-Marie; Adamali, Huzaifa; Molyneaux, Philip L.; Lukey, Pauline T.; Marshall, Richard P.; Renzoni, Elisabetta A.; Wells, Athol U.
2016-01-01
Rationale: Recent clinical trial successes have created an urgent need for earlier and more sensitive endpoints of disease progression in idiopathic pulmonary fibrosis (IPF). Domiciliary spirometry permits more frequent measurement of FVC than does hospital-based assessment, which therefore affords the opportunity for a more granular insight into changes in IPF progression. Objectives: To determine the feasibility and reliability of measuring daily FVC in individuals with IPF. Methods: Subjects with IPF were given handheld spirometers and instruction on how to self-administer spirometry. Subjects recorded daily FEV1 and FVC for up to 490 days. Clinical assessment and hospital-based spirometry was undertaken at 6 and 12 months, and outcome data were collected for 3 years. Measurements and Main Results: Daily spirometry was recorded by 50 subjects for a median period of 279 days (range, 13–490 d). There were 18 deaths during the active study period. Home spirometry showed excellent correlation with hospital-obtained readings. The rate of decline in FVC was highly predictive of outcome and subsequent mortality when measured at 3 months (hazard ratio [HR], 1.040; 95% confidence interval [CI], 1.021–1.062; P ≤ 0.001), 6 months (HR, 1.024; 95% CI, 1.014–1.033; P < 0.001), and 12 months (HR, 1.012; 95% CI, 1.007–1.016; P = 0.001). Conclusions: Measurement of daily home spirometry in patients with IPF is highly clinically informative and is feasible to perform for most of these patients. The relationship between mortality and rate of change of FVC at 3 months suggests that daily FVC may be of value as a primary endpoint in short proof-of-concept IPF studies. PMID:27089018
Pulmonary Function and Respiratory Health of Military Personnel Before Southwest Asia Deployment.
Skabelund, Andrew J; Rawlins, Frederic A; McCann, Edward T; Lospinoso, Joshua A; Burroughs, Lorraine; Gallup, Roger A; Morris, Michael J
2017-09-01
Significant concern exists regarding the respiratory health of military personnel deployed to Southwest Asia, given their exposures to numerous environmental hazards. Although the deployed military force is generally assumed to be fit, the pre-deployment respiratory health of these individuals is largely unknown. Soldiers deploying to Southwest Asia were recruited from the pre-deployment processing center at Fort Hood, Texas. Participants completed a general and respiratory health questionnaire and performed baseline spirometry. One thousand six hundred ninety-three pre-deployment evaluations were completed. The average age of the participants was 32.2 y, and 83.1% were male. More than one third of surveyed solders had a smoking history, 73% were overweight or obese, and 6.2% reported a history of asthma. Abnormal spirometry was found in 22.3% of participants. Soldiers with abnormal spirometry reported more asthma (10.1% vs 5.1%, P < .001), failed physical fitness tests (9.0% vs 4.6%, P = .02), and respiratory symptoms (32.8% vs 24.3%, P = .001). This is the first prospective pre-deployment evaluation of military personnel that delineates factors potentially associated with the development of pulmonary symptoms and/or disease. This study suggests that deploying soldiers are older, heavier, frequently smoke, and may have undiagnosed pre-deployment lung disease. Abnormal spirometry is common but may not represent underlying disease. Self-reported asthma, wheezing, and slower 2-mile run times were predictive of abnormal spirometry. Pre-deployment evaluation of military personnel identified numerous soldiers with active pulmonary symptoms and abnormal spirometry. When combined with questions regarding asthma history, wheezing and exercise intolerance, spirometry may identify individuals at risk for deployment-related respiratory complaints. Copyright © 2017 by Daedalus Enterprises.
Agiovlasitis, Stamatis; Motl, Robert W
2016-01-01
An equation for predicting the gross oxygen uptake (gross-VO2) during walking for persons with multiple sclerosis (MS) has been developed. Predictors included walking speed and total score from the 12-Item Multiple Sclerosis Walking Scale (MSWS-12). This study examined the validity of this prediction equation in another sample of persons with MS. Participants were 18 persons with MS with limited mobility problems (42 ± 13 years; 14 women). Participants completed the MSWS-12. Gross-VO2 was measured with open-circuit spirometry during treadmill walking at 2.0, 3.0, and 4.0 mph (0.89, 1.34, and 1.79 m·s(-1)). Absolute percent error was small: 8.3 ± 6.1% , 8.0 ± 5.6% , and 12.2 ± 9.0% at 2.0, 3.0, and 4.0 mph, respectively. Actual gross-VO2 did not differ significantly from predicted gross-VO2 at 2.0 and 3.0 mph, but was significantly higher than predicted gross-VO2 at 4.0 mph (p < 0.001). Bland-Altman plots indicated nearly zero mean difference between actual and predicted gross-VO2 with modest 95% confidence intervals at 2.0 and 3.0 mph, but there was some underestimation at 4.0 mph. Speed and MSWS-12 score provide valid prediction of gross-VO2 during treadmill walking at slow and moderate speeds in ambulatory persons with MS. However, there is a possibility of small underestimation for walking at 4.0 mph.
[Cardiopulmonary dynamics during a maximal exertion test in Mexican endurance athletes].
Padilla, J; Martínez, E; Olvera, G; Ojeda Cruz, P; Caudillo Pérez, D
2000-01-01
To search for cardiopulmonary (CP) kinetic and dynamic differences between Mexican resistance athletes (RES = 10) and non athletes (NON = 19). From the expired volume (Ve), measured by an open circuit spirometry, we calculated both VO2 and VCO2 during stress test while the volunteer pedalled seated on an electronic cycloergometer that started at 50 W.2 min-1 followed by increments of 25 W.2 min-1 each, until VO2máx was reached. The exercise transient time course (min) response (VO2, VCO2, Ve and heart rate, HR; and also O2 pulse, PulO2) was transformed to seconds and modelled by computer using linear regression technique by the interactive minimum squares method, and the mean response time (MRT) was used as an overall kinetic CP parameter. The transient MRTs for VO2, VCO2 and Ve were slow in RES compared to NON. While the transient CP dynamics in NON lasted MRT_VO2 < (MRT_PulO2, MRT_FC) < MRT_VCO2 < MRT_Ve; the RES: both MRT_PulO2 and MRT_HR shifted to the right ((MRT_VO2, MRT_VCO2) < (MRT_PulO2, MRT_FC) < MRT_Ve). The relationships between the best sport profit mean velocity and both the MRT_VO2, MRT_VCO2 and MRT_PulO2 (GEK = gas exchange kinetics) showed fast_RES and slow_GEK, and slow_RES and fast_GEK. The transient CP kinetics was slow in RES compared NON. It is possible to distinguish cardiopulmonary kinetic differences among resistance athletes holding different sport profiles.
Correlation of energy disorder and open-circuit voltage in hybrid perovskite solar cells
Shao, Yuchuan; Yuan, Yongbo; Huang, Jinsong
2016-01-11
Organometal trihalide perovskites have been demonstrated as excellent light absorbers for high efficiency photovoltaic applications. Previous approaches to increasing the solar cell efficiency have focussed on optimisation of the grain morphology of perovskite thin films. Here, we show that the structural order of the electron-transport layers also has a significant impact on solar cell performance. We demonstrate that the power conversion efficiency of CH 3NH 3PbI 3 planar-heterojunction photovoltaic cells increases from 17.1% to 19.4% when the energy disorder in the fullerene electron-transport layer is reduced by a simple solvent annealing process. The increase in efficiency is the result ofmore » the enhancement in open-circuit voltage from 1.04 V to 1.13 V without sacrificing the short-circuit current and fill factor. Finally, these results shed light on the origin of open-circuit voltage in perovskite solar cells, and provide a new path to further increase their efficiency« less
Chani, Muhammad Tariq Saeed; Karimov, Kh S; Asiri, Abdullah M; Ahmed, Nisar; Bashir, Muhammad Mehran; Khan, Sher Bahadar; Rub, Malik Abdul; Azum, Naved
2014-01-01
This work presents the fabrication and investigation of thermoelectric cells based on composite of carbon nanotubes (CNT) and silicone adhesive. The composite contains CNT and silicon adhesive 1∶1 by weight. The current-voltage characteristics and dependences of voltage, current and Seebeck coefficient on the temperature gradient of cell were studied. It was observed that with increase in temperature gradient the open circuit voltage, short circuit current and the Seebeck coefficient of the cells increase. Approximately 7 times increase in temperature gradient increases the open circuit voltage and short circuit current up to 40 and 5 times, respectively. The simulation of experimental results is also carried out; the simulated results are well matched with experimental results.
Temperature Gradient Measurements by Using Thermoelectric Effect in CNTs-Silicone Adhesive Composite
Chani, Muhammad Tariq Saeed; Karimov, Kh. S.; Asiri, Abdullah M.; Ahmed, Nisar; Bashir, Muhammad Mehran; Khan, Sher Bahadar; Rub, Malik Abdul; Azum, Naved
2014-01-01
This work presents the fabrication and investigation of thermoelectric cells based on composite of carbon nanotubes (CNT) and silicone adhesive. The composite contains CNT and silicon adhesive 1∶1 by weight. The current-voltage characteristics and dependences of voltage, current and Seebeck coefficient on the temperature gradient of cell were studied. It was observed that with increase in temperature gradient the open circuit voltage, short circuit current and the Seebeck coefficient of the cells increase. Approximately 7 times increase in temperature gradient increases the open circuit voltage and short circuit current up to 40 and 5 times, respectively. The simulation of experimental results is also carried out; the simulated results are well matched with experimental results. PMID:24748375
Relationship of Open-Circuit Voltage to CdTe Hole Concentration and Lifetime
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duenow, Joel N.; Burst, James M.; Albin, David S.
We investigate the correlation of bulk CdTe and CdZnTe material properties with experimental open-circuit voltage (Voc) through fabrication and characterization of diverse single-crystal solar cells with different dopants. Several distinct crystal types reach Voc >900 mV. Correlations are in general agreement with Voc limits modeled from bulk minority-carrier lifetime and hole concentration.
Studies of silicon p-n junction solar cells. [open circuit photovoltage
NASA Technical Reports Server (NTRS)
Lindholm, F. A.
1976-01-01
Single crystal silicon p-n junction solar cells made with low resistivity substrates show poorer solar energy conversion efficiency than traditional theory predicts. The physical mechanisms responsible for this discrepancy are identified and characterized. The open circuit voltage in shallow junction cells of about 0.1 ohm/cm substrate resistivity is investigated under AMO (one sun) conditions.
De Marco, Nicholas; Zhou, Huanping; Chen, Qi; Sun, Pengyu; Liu, Zonghao; Meng, Lei; Yao, En-Ping; Liu, Yongsheng; Schiffer, Andy; Yang, Yang
2016-02-10
Hybrid perovskites have shown astonishing power conversion efficiencies owed to their remarkable absorber characteristics including long carrier lifetimes, and a relatively substantial defect tolerance for solution-processed polycrystalline films. However, nonradiative charge carrier recombination at grain boundaries limits open circuit voltages and consequent performance improvements of perovskite solar cells. Here we address such recombination pathways and demonstrate a passivation effect through guanidinium-based additives to achieve extraordinarily enhanced carrier lifetimes and higher obtainable open circuit voltages. Time-resolved photoluminescence measurements yield carrier lifetimes in guanidinium-based films an order of magnitude greater than pure-methylammonium counterparts, giving rise to higher device open circuit voltages and power conversion efficiencies exceeding 17%. A reduction in defect activation energy of over 30% calculated via admittance spectroscopy and confocal fluorescence intensity mapping indicates successful passivation of recombination/trap centers at grain boundaries. We speculate that guanidinium ions serve to suppress formation of iodide vacancies and passivate under-coordinated iodine species at grain boundaries and within the bulk through their hydrogen bonding capability. These results present a simple method for suppressing nonradiative carrier loss in hybrid perovskites to further improve performances toward highly efficient solar cells.
Sinharay, Arijit; Rakshit, Raj; Chakravarty, Tapas; Ghosh, Deb; Pal, Arpan
2017-01-01
Pulmonary ailments are conventionally diagnosed by spirometry. The complex forceful breathing maneuver as well as the extreme cost of spirometry renders it unsuitable in many situations. This work is aimed to facilitate an emerging direction of tidal breathing-based pulmonary evaluation by designing a novel, equitable, precise and portable device for acquisition and analysis of directional tidal breathing patterns, in real time. The proposed system primarily uses an in-house designed blow pipe, 40-kHz air-coupled ultrasound transreceivers, and a radio frequency (RF) phase-gain integrated circuit (IC). Moreover, in order to achieve high sensitivity in a cost-effective design philosophy, we have exploited the phase measurement technique, instead of selecting the contemporary time-of-flight (TOF) measurement; since application of the TOF principle in tidal breathing assessments requires sub-micro to nanosecond time resolution. This approach, which depends on accurate phase measurement, contributed to enhanced sensitivity using a simple electronics design. The developed system has been calibrated using a standard 3-L calibration syringe. The parameters of this system are validated against a standard spirometer, with maximum percentage error below 16%. Further, the extracted respiratory parameters related to tidal breathing have been found to be comparable with relevant prior works. The error in detecting respiration rate only is 3.9% compared to manual evaluation. These encouraging insights reveal the definite potential of our tidal breathing pattern (TBP) prototype for measuring tidal breathing parameters in order to extend the reach of affordable healthcare in rural regions and developing areas. PMID:28800103
Cooper, James A.
1986-01-01
A logic circuit is used to enhance redundant switch reliability. Two or more switches are monitored for logical high or low output. The output for the logic circuit produces a redundant and failsafe representation of the switch outputs. When both switch outputs are high, the output is high. Similarly, when both switch outputs are low, the logic circuit's output is low. When the output states of the two switches do not agree, the circuit resolves the conflict by memorizing the last output state which both switches were simultaneously in and produces the logical complement of this output state. Thus, the logic circuit of the present invention allows the redundant switches to be treated as if they were in parallel when the switches are open and as if they were in series when the switches are closed. A failsafe system having maximum reliability is thereby produced.
NASA Technical Reports Server (NTRS)
Thomas, R. E.
1972-01-01
Twenty-five cells were used in a five-year test to compare, after each successive one-year storage period, the discharge and charge characteristics of charged cells on open circuit versus that of cells on continuous trickle charge. The test procedure, instrumentation, and results are described. Based on the test results, the following recommendations were made: (1) If the user's purpose will allow a rejuvenation cycle or two after a long storage period, the open circuit regime will likely give slightly greater capacity. (2) If the user's purpose demands immediately available power following a long storage period, the trickle charge method of storage is definitely the regime to use.
NASA Technical Reports Server (NTRS)
Minnucci, J. A.; Matthei, K. W.
1980-01-01
The results of a 14 month program to improve the open circuit voltage of low resistivity silicon solar cells are described. The approach was based on ion implantation in 0.1- to 10.0-ohm-cm float-zone silicon. As a result of the contract effort, open circuit voltages as high as 645 mV (AMO 25 C) were attained by high dose phosphorus implantation followed by furnace annealing and simultaneous SiO2 growth. One key element was to investigate the effects of bandgap narrowing caused by high doping concentrations in the junction layer. Considerable effort was applied to optimization of implant parameters, selection of furnace annealing techniques, and utilization of pulsed electron beam annealing to minimize thermal process-induced defects in the completed solar cells.
46 CFR 120.380 - Overcurrent protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch or circuit breaker, unless...
46 CFR 120.380 - Overcurrent protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch or circuit breaker, unless...
14 CFR 29.1357 - Circuit protective devices.
Code of Federal Regulations, 2013 CFR
2013-01-01
... devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their associated buses with sufficient rapidity to provide protection... be designed so that, when an overload or circuit fault exists, it will open the circuit regardless of...
14 CFR 29.1357 - Circuit protective devices.
Code of Federal Regulations, 2014 CFR
2014-01-01
... devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their associated buses with sufficient rapidity to provide protection... be designed so that, when an overload or circuit fault exists, it will open the circuit regardless of...
14 CFR 29.1357 - Circuit protective devices.
Code of Federal Regulations, 2011 CFR
2011-01-01
... devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their associated buses with sufficient rapidity to provide protection... be designed so that, when an overload or circuit fault exists, it will open the circuit regardless of...
14 CFR 29.1357 - Circuit protective devices.
Code of Federal Regulations, 2012 CFR
2012-01-01
... devices in the generating system must be designed to de-energize and disconnect faulty power sources and power transmission equipment from their associated buses with sufficient rapidity to provide protection... be designed so that, when an overload or circuit fault exists, it will open the circuit regardless of...
Code of Federal Regulations, 2013 CFR
2013-07-01
... circuit directly they shall be of the multipole type. (b) Where electronic devices are used they shall be... will be forced straight, tripping the switch and opening the electrical circuit. (8) Step (platform). A... at landings.) (ii) Control of illumination. Lighting of manlift runways shall be by means of circuits...
An improved method for piezoelectric characterization of polymers for energy harvesting applications
NASA Astrophysics Data System (ADS)
Gusarova, E.; Gusarov, B.; Zakharov, D.; Bousquet, M.; Viala, B.; Cugat, O.; Delamare, J.; Gimeno, L.
2013-12-01
This work presents an improved method for measuring the direct piezoelectric voltage and energy of flexible polymers. Well-controlled stress is applied with a four-point bending system and voltage is measured in real open-circuit conditions. The presented method separates the piezoelectric part from the measurement part by introducing a mechanical switch, allowing instantaneous post-deformation discharge measurements. Oscilloscope and contact-less electrostatic voltmeter are compared. Direct piezoelectric measurements under open-circuit conditions have been performed on commercial PVDF (polyvinylidene fluoride) and its copolymers. Significant differences to data sheet values (close-circuit conditions) are reported and commented.
NASA Astrophysics Data System (ADS)
Arata, Shigeki; Hayashi, Kenya; Nishio, Yuya; Kobayashi, Atsuki; Nakazato, Kazuo; Niitsu, Kiichi
2018-04-01
The world’s smallest (0.36 mm2) solid-state CMOS-compatible glucose fuel cell, which exhibits an open-circuit voltage (OCV) of 228 mV and a power generation density of 1.32 µW/cm2 with a 30 mM glucose solution, is reported in this paper. Compared with conventional wet etching, dry etching (reactive ion etching) for patterning minimizes damage to the anode and cathode, resulting in a cell with a small size and a high OCV, sufficient for CMOS circuit operation.
Trade Electricity. Signal Wiring--Level 1. Standardized Curriculum.
ERIC Educational Resources Information Center
New York City Board of Education, Brooklyn, NY. Office of Occupational and Career Education.
This curriculum guide consists of nine modules on signal wiring, one of the three divisions of the standardized trade electricity curriculum in high schools in New York City. The modules cover the following subjects: bells, double contact pushbuttons, annunciator circuits, open circuit burglar alarms, closed circuit burglar alarms, fire alarms,…
Textbook Error: Short Circuiting on Electrochemical Cell
ERIC Educational Resources Information Center
Bonicamp, Judith M.; Clark, Roy W.
2007-01-01
Short circuiting an electrochemical cell is an unreported but persistent error in the electrochemistry textbooks. It is suggested that diagrams depicting a cell delivering usable current to a load be postponed, the theory of open-circuit galvanic cells is explained, the voltages from the tables of standard reduction potentials is calculated and…
21 CFR 868.5250 - Breathing circuit circulator.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breathing circuit circulator. 868.5250 Section 868.5250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... valves in an open position and reducing mechanical dead space and resistance in the breathing circuit. (b...
21 CFR 868.5250 - Breathing circuit circulator.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breathing circuit circulator. 868.5250 Section 868.5250 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... valves in an open position and reducing mechanical dead space and resistance in the breathing circuit. (b...
Taped Random Spectra for Reliability Demonstration Testing
1981-04-01
circuit , barrier strip terminals 9A and 9B. Closure of the normally-open contacts provides the gate current necessary to trigger the control TRIAC ... Circuit contains a TRIAC , DIAC, Reed Relay (R3) and the Tape Running Relay Driver. The Cam on/off switching is accomplished through the barrier strip...2-25 2I; Input Power Circuit .. .. .... ...... ...... ...... ........... 2-26 2-13 Typical Control Circuit
Sullivan, Scott C; Fansler, Douglas
2014-10-14
A vehicle having multiple isolated fluid circuits configured to be filled through a common fill port includes a first fluid circuit disposed within the vehicle, the first fluid circuit having a first fill port, a second fluid circuit disposed within the vehicle, and a conduit defining a fluid passageway between the first fluid circuit and second fluid circuit, the conduit including a valve. The valve is configured such that the first and second fluid circuits are fluidly coupled via the passageway when the valve is open, and are fluidly isolated when the valve is closed.
Coal Mining-Related Respiratory Diseases
... Radiography Spirometry Follow NIOSH Facebook Flickr Pinterest Twitter YouTube NIOSH Homepage NIOSH A-Z Workplace Safety & Health ... Radiography Spirometry Follow NIOSH Facebook Flickr Pinterest Twitter YouTube NIOSH Homepage NIOSH A-Z Workplace Safety & Health ...
Goyal, Vipin Kumar; Bhargava, Suresh Kumar; Baj, Birbal
2017-10-01
Fentanyl-induced cough (FIC) has a reported incidence of 13-65% on induction of anesthesia. Incentive spirometry (IS) creates forceful inspiration, while stretching pulmonary receptors. We postulated that spirometry just before the fentanyl (F) bolus would decrease the incidence and severity of FIC. This study enrolled 200 patients aged 18-60 years and with American Society of Anesthesiologists status I or II. The patients were allocated to two groups of 100 patients each depending on whether they received preoperative incentive spirometry before fentanyl administration. Patients in the F+IS group performed incentive spirometry 10 times just before an intravenous bolus of 3 µg/kg fentanyl in the operating room. The onset time and number of coughs after fentanyl injection were recorded as primary outcomes. Any significant changes in blood pressure, heart rate, or adverse effects of the drug were recorded as secondary outcomes. Patients in the F+IS group had a significantly lower incidence of FIC than in the F group (6% vs. 26%) (P < 0.05). The severity of cough in the F+IS group was also significantly lower than that in group F (mild, 5 vs. 17; moderate 1 vs. 7; severe, 0 vs. 2) (P < 0.05). The median onset time was comparable in both groups (9 s [range: 6-12 s] in both groups). Preoperative incentive spirometry significantly reduces the incidence and severity of FIC when performed just before fentanyl administration.
Bhargava, Suresh Kumar; Baj, Birbal
2017-01-01
Background Fentanyl-induced cough (FIC) has a reported incidence of 13–65% on induction of anesthesia. Incentive spirometry (IS) creates forceful inspiration, while stretching pulmonary receptors. We postulated that spirometry just before the fentanyl (F) bolus would decrease the incidence and severity of FIC. Methods This study enrolled 200 patients aged 18–60 years and with American Society of Anesthesiologists status I or II. The patients were allocated to two groups of 100 patients each depending on whether they received preoperative incentive spirometry before fentanyl administration. Patients in the F+IS group performed incentive spirometry 10 times just before an intravenous bolus of 3 µg/kg fentanyl in the operating room. The onset time and number of coughs after fentanyl injection were recorded as primary outcomes. Any significant changes in blood pressure, heart rate, or adverse effects of the drug were recorded as secondary outcomes. Results Patients in the F+IS group had a significantly lower incidence of FIC than in the F group (6% vs. 26%) (P < 0.05). The severity of cough in the F+IS group was also significantly lower than that in group F (mild, 5 vs. 17; moderate 1 vs. 7; severe, 0 vs. 2) (P < 0.05). The median onset time was comparable in both groups (9 s [range: 6–12 s] in both groups). Conclusions Preoperative incentive spirometry significantly reduces the incidence and severity of FIC when performed just before fentanyl administration. PMID:29046775
Resonator reset in circuit QED by optimal control for large open quantum systems
NASA Astrophysics Data System (ADS)
Boutin, Samuel; Andersen, Christian Kraglund; Venkatraman, Jayameenakshi; Ferris, Andrew J.; Blais, Alexandre
2017-10-01
We study an implementation of the open GRAPE (gradient ascent pulse engineering) algorithm well suited for large open quantum systems. While typical implementations of optimal control algorithms for open quantum systems rely on explicit matrix exponential calculations, our implementation avoids these operations, leading to a polynomial speedup of the open GRAPE algorithm in cases of interest. This speedup, as well as the reduced memory requirements of our implementation, are illustrated by comparison to a standard implementation of open GRAPE. As a practical example, we apply this open-system optimization method to active reset of a readout resonator in circuit QED. In this problem, the shape of a microwave pulse is optimized such as to empty the cavity from measurement photons as fast as possible. Using our open GRAPE implementation, we obtain pulse shapes, leading to a reset time over 4 times faster than passive reset.
Venkatesan, Swaminathan; Ngo, Evan C; Chen, Qiliang; Dubey, Ashish; Mohammad, Lal; Adhikari, Nirmal; Mitul, Abu Farzan; Qiao, Qiquan
2014-06-21
Single and double junction solar cells with high open circuit voltage were fabricated using poly{thiophene-2,5-diyl-alt-[5,6-bis(dodecyloxy)benzo[c][1,2,5]thiadiazole]-4,7-diyl} (PBT-T1) blended with fullerene derivatives in different weight ratios. The role of fullerene loading on structural and morphological changes was investigated using atomic force microscopy (AFM) and X-ray diffraction (XRD). The XRD and AFM measurements showed that a higher fullerene mixing ratio led to breaking of inter-chain packing and hence resulted in smaller disordered polymer domains. When the PBT-T1:PC60BM weight ratio was 1 : 1, the polymer retained its structural order; however, large aggregated domains formed, leading to poor device performance due to low fill factor and short circuit current density. When the ratio was increased to 1 : 2 and then 1 : 3, smaller amorphous domains were observed, which improved photovoltaic performance. The 1 : 2 blending ratio was optimal due to adequate charge transport pathways giving rise to moderate short circuit current density and fill factor. Adding 1,8-diiodooctane (DIO) additive into the 1 : 2 blend films further improved both the short circuit current density and fill factor, leading to an increased efficiency to 4.5% with PC60BM and 5.65% with PC70BM. These single junction solar cells exhibited a high open circuit voltage at ∼ 0.9 V. Photo-charge extraction by linearly increasing voltage (Photo-CELIV) measurements showed the highest charge carrier mobility in the 1 : 2 film among the three ratios, which was further enhanced by introducing the DIO. The Photo-CELIV measurements with varying delay times showed significantly higher extracted charge carrier density for cells processed with DIO. Tandem devices using P3HT:IC60BA as bottom cell and PBT-T1:PC60BM as top cell exhibited a high open circuit voltage of 1.62 V with 5.2% power conversion efficiency.
Cho, Y J; Ryu, H; Lee, J; Park, I K; Kim, Y T; Lee, Y H; Lee, H; Hong, D M; Seo, J H; Bahk, J H; Jeon, Y
2014-08-01
Lung resection surgery has been associated with numerous postoperative complications. Seventy-eight patients scheduled for elective video-assisted thoracoscopic lung resection were randomly assigned to receive standard postoperative care with incentive spirometry or standard care plus positive vibratory expiratory pressure treatment using the Acapella(®) device. There was no significant difference between incentive spirometry and the Acapella device in the primary outcome, forced expiratory volume in 1 s, on the third postoperative day, mean (SD) 53% (16%) vs 59% (18%) respectively, p = 0.113. Patients treated with both devices simultaneously found incentive spirometry to be less comfortable compared with the Acapella device, using a numeric rating scale from 1 to 5 with lower scores indicating higher comfort, median (IQR [range]) 3 (2-3 [2-4]) vs 1 (1-2 [1-3]) respectively, p < 0.001. In addition, 37/39 patients (95%) stated a clear preference for the Acapella device. Postoperative treatment with the Acapella device did not improve pulmonary function after thoracoscopic lung resection surgery compared with incentive spirometry, but it may be more comfortable to use. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
[Accesibility and use of spirometry in primary care centers in Catalonia].
Llauger, M Antònia; Rosas, Alba; Burgos, Felip; Torrente, Elena; Tresserras, Ricard; Escarrabill, Joan
2014-01-01
Examine the accessibility and use of forced spirometry (FS) in public primary care facilities centers in Catalonia. Cross-sectional study using a survey. Three hundred sixty-six Primary Care Teams (PCT) in Catalonia. Third quarter of 2010. Survey with information on spirometers, training, interpretation and quality control, and the priority that the quality of spirometry had for the team. Indicators FS/100 inhabitants/year, FS/month/PCT; FS/month/10,000 inhabitants. Response rate: 75%. 97.5% of PCT had spirometer and made an average of 2.01 spirometries/100 inhabitants (34.68 spirometry/PCT/month). 83% have trained professionals.>50% centers perform formal training but no information is available on the quality. 70% performed some sort of calibration. Interpretation was made by the family physician in 87.3% of cases. In 68% of cases not performed any quality control of exploration. 2/3 typed data manually into the computerized medical record.>50% recognized a high priority strategies for improving the quality. Despite the accessibility of EF efforts should be made to standardize training, increasing the number of scans test and promote systematic quality control. Copyright © 2013 Elsevier España, S.L. All rights reserved.
Thermodynamic derivation of open circuit voltage in vanadium redox flow batteries
NASA Astrophysics Data System (ADS)
Pavelka, Michal; Wandschneider, Frank; Mazur, Petr
2015-10-01
Open circuit voltage of vanadium redox flow batteries is carefully calculated using equilibrium thermodynamics. This analysis reveals some terms in the Nernst relation which are usually omitted in literature. Due to the careful thermodynamic treatment, all uncertainties about the form of Nernst relation are removed except for uncertainties in activity coefficients of particular species. Moreover, it is shown (based again on equilibrium thermodynamics) that batteries with anion-exchange membranes follow different Nernst relation than batteries with cation-exchange membranes. The difference is calculated, and it is verified experimentally that the formula for anion-exchange membranes describes experiments with anion-exchange membranes better than the corresponding formula for cation-exchange membranes. In summary, careful thermodynamic calculation of open circuit voltage of vanadium redox flow batteries is presented, and the difference between voltage for anion-exchange and cation-exchange membranes is revealed.
NASA Technical Reports Server (NTRS)
Reid, M. A.; Gahn, R. F.
1977-01-01
Performance of the iron-titanium redox flow cell was studied as a function of acid concentration. Anion permeable membranes separated the compartments. Electrodes were graphite cloth. Current densities ranged up to 25 mA/square centimeter. Open-circuit and load voltages decreased as the acidity was increased on the iron side as predicted. On the titanium side, open-circuit voltages decreased as the acidity was increased in agreement with theory, but load voltages increased due to decreased polarization with increasing acidity. High acidity on the titanium side coupled with low acidity on the iron side gives the best load voltage, but such cells show voltage losses as they are repeatedly cycled. Analyses show that the bulk of the voltage losses are due to diffusion of acid through the membrane.
Coupling Spatial Segregation with Synthetic Circuits to Control Bacterial Survival (Open Access)
2016-02-29
Subject Categories Synthetic Biology & Biotechnology; Quantitative Biology & Dynamical Systems DOI 10.15252/msb.20156567 | Received 9 September 2015...survival. Experimentally , we program collective survival using three different gene circuits, which allow us to evaluate the modularity of the...QS-CAT circuit depends on QS regulation. The QS-BlaM circuit depends on both QS regulation and enzyme release (by lysis and export). G–I Experimental
Improved High/Low Junction Silicon Solar Cell
NASA Technical Reports Server (NTRS)
Neugroschel, A.; Pao, S. C.; Lindholm, F. A.; Fossum, J. G.
1986-01-01
Method developed to raise value of open-circuit voltage in silicon solar cells by incorporating high/low junction in cell emitter. Power-conversion efficiency of low-resistivity silicon solar cell considerably less than maximum theoretical value mainly because open-circuit voltage is smaller than simple p/n junction theory predicts. With this method, air-mass-zero opencircuit voltage increased from 600 mV level to approximately 650 mV.
ERIC Educational Resources Information Center
Boettcher, Kenneth D.
American River College (Calif.) devised an experimental program in remedial English intended to better prepare entering freshmen. It was given by open-circuit TV simultaneously to high school seniors and junior college freshmen in the hope that, in subsequent years, there would be fewer inadequately prepared freshmen and that more could enroll…
Impulse commutating circuit with transformer to limit reapplied voltage
NASA Technical Reports Server (NTRS)
Mcconville, J. H.
1973-01-01
Silicon controlled rectifier opens circuit with currents flowing up to values of 30 amperes. Switching concept halves both current and voltage in middle of commutating cycle thereby lowering size and weight requirements. Commutating circuit can be turned on or off by command and will remain on in absence of load due to continuous gate.
30 CFR 57.6404 - Separation of blasting circuits from power source.
Code of Federal Regulations, 2010 CFR
2010-07-01
... source. 57.6404 Section 57.6404 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... circuits from power source. (a) Switches used to connect the power source to a blasting circuit shall be locked in the open position except when closed to fire the blast. (b) Lead wires shall not be connected...
Biobatteries and biofuel cells with biphenylated carbon nanotubes
NASA Astrophysics Data System (ADS)
Stolarczyk, Krzysztof; Kizling, Michał; Majdecka, Dominika; Żelechowska, Kamila; Biernat, Jan F.; Rogalski, Jerzy; Bilewicz, Renata
2014-03-01
Single-walled carbon nanotubes (SWCNTs) covalently biphenylated are used for the construction of cathodes in a flow biobattery and in flow biofuel cell. Zinc covered with a hopeite layer is the anode in the biobattery and glassy carbon electrode covered with bioconjugates of single-walled carbon nanotubes with glucose oxidase and catalase is the anode of the biofuel cell. The potentials of the electrodes are measured vs. the Ag/AgCl reference electrode under changing loads of the fuel cell/biobattery. The power density of the biobattery with biphenylated nanotubes at the cathode is ca. 0.6 mW cm-2 and the open circuit potential is ca. 1.6 V. In order to obtain larger power densities and voltages three biobatteries are connected in a series which leads to the open circuit potential of ca. 4.8 V and power density 2.1 mW cm-2 at 3.9 V under 100 kΩ load. The biofuel cell shows power densities of ca. 60 μW cm-2 at 20 kΩ external resistance but the open circuit potential for such biofuel cell is only 0.5 V. The biobattery showing significantly larger power densities and open circuit voltages are especially useful for testing novel cathodes and applications such as powering units for clocks and sensing devices.
Further study of inversion layer MOS solar cells
NASA Technical Reports Server (NTRS)
Ho, Fat Duen
1987-01-01
A group of inversion layer MOS solar cells has been fabricated. The highest value of open-circuit voltage obtained for the cells is 0.568V. One of the cells has produced a short-circuit current of 79.6 mA and an open-circuit voltage of 0.54V. It is estimated that the actual area AMO efficiency of this cell is 6.6 percent with an assumed value of 0.75 for its fill factor. Efforts made for fabricating an IL/MOS cell with reasonable efficiencies are reported. Future work for 4 sq cm IL cells and 25 sq cm IL cells is discussed.
Schermer, Tjard R; Akkermans, Reinier P; Crockett, Alan J; van Montfort, Marian; Grootens-Stekelenburg, Joke; Stout, Jim W; Pieters, Willem
2011-01-01
Spirometry has become an indispensable tool in primary care to exclude, diagnose, and monitor chronic respiratory conditions, but the quality of spirometry tests in family practices is a reason for concern. Aim of this study was to investigate whether a combination of e-learning and bimonthly performance feedback would improve spirometry test quality in family practices in the course of 1 year. Our study was a cluster trial with 19 family practices allocated to intervention or control conditions through minimization. Intervention consisted of e-learning and bimonthly feedback reports to practice nurses. Control practices received only the joint baseline workshop. Spirometry quality was assessed by independent lung function technicians. Two outcomes were defined, with the difference between rates of tests with 2 acceptable and repeatable blows being the primary outcome and the difference between rates of tests with 2 acceptable blows being the secondary outcome. We used multilevel logistic regression analysis to calculate odds ratios (ORs) for an adequate test in intervention group practices. We analyzed 1,135 tests. Rate of adequate tests was 33% in intervention and 30% in control group practices (OR = 1.3; P=.605). Adequacy of tests did not differ between groups but tended to increase with time: OR = 2.2 (P = .057) after 3 and OR = 2.0 (P = .086) in intervention group practices after 4 feedback reports. When ignoring test repeatability, these differences between the groups were slightly more pronounced: OR = 2.4 (P = .033) after 3 and OR=2.2 (P = .051) after 4 feedback reports. In the course of 1 year, we observed a small and late effect of e-learning and repeated feedback on the quality of spirometry as performed by family practice nurses. This intervention does not seem to compensate the lack of rigorous training and experience in performing spirometry tests in most practices.
Odo, Nnaemeka U; Mandel, Jeffrey H; Perlman, David M; Alexander, Bruce H; Scanlon, Paul D
2013-01-01
Objectives (1) To assess the impact of American Thoracic Society and European Respiratory Society (ATS/ERS) ‘acceptability’ and ‘usability’ criteria for spirometry on the estimates of restrictive ventilatory defect in a population of taconite miners. (2) To compare estimates of restrictive ventilatory defect with three different pulmonary function tests (spirometry, alveolar volume (VA) and diffusing capacity (DL,CO)). (3) To assess the role of population characteristics on these estimates. Design Cross-sectional study. Setting Current and former workers in six current taconite mining operations of northeastern Minnesota were surveyed. Participants We attempted to enrol 3313 participants. Of these, 1353 responded while 1188 current and former workers fully participated in the survey and 1084 performed complete pulmonary function testing and were assessed. Primary and secondary outcome measures We applied ATS/ERS acceptability criteria for all tests and categorised participants into groups according to whether they fully met, partially met or did not meet acceptability criteria for spirometry. Obstruction and restriction were defined utilising the lower limit of normal for all tests. When using VA, restriction was identified after excluding obstruction. Results Only 519 (47.9%) tests fully met ATS/ERS spirometry acceptability criteria. Within this group, 5% had obstruction and 6%, restriction on spirometry. In contrast, among all participants (N=1084), 16.8% had obstruction, while 4.5% had restriction. VA showed similar results in all groups after obstruction was excluded. Impaired gas transfer (reduced DL,CO) was identified in less than 50% of restriction identified by either spirometry or VA. Body mass index (BMI) was significantly related to spirometric restriction in all groups. Conclusions Population estimates of restriction using spirometry or VA varied by spirometric acceptability criteria. Other factors identified as important considerations in the estimation of restrictive ventilatory defect included increased BMI and gas transfer impairment in a relatively smaller proportion of those with spirometric restriction. These insights are important when interpreting population-based physiological data in occupational settings. PMID:23869101
Odo, Nnaemeka U; Mandel, Jeffrey H; Perlman, David M; Alexander, Bruce H; Scanlon, Paul D
2013-01-01
(1) To assess the impact of American Thoracic Society and European Respiratory Society (ATS/ERS) 'acceptability' and 'usability' criteria for spirometry on the estimates of restrictive ventilatory defect in a population of taconite miners. (2) To compare estimates of restrictive ventilatory defect with three different pulmonary function tests (spirometry, alveolar volume (VA) and diffusing capacity (DL,CO)). (3) To assess the role of population characteristics on these estimates. Cross-sectional study. Current and former workers in six current taconite mining operations of northeastern Minnesota were surveyed. We attempted to enrol 3313 participants. Of these, 1353 responded while 1188 current and former workers fully participated in the survey and 1084 performed complete pulmonary function testing and were assessed. We applied ATS/ERS acceptability criteria for all tests and categorised participants into groups according to whether they fully met, partially met or did not meet acceptability criteria for spirometry. Obstruction and restriction were defined utilising the lower limit of normal for all tests. When using VA, restriction was identified after excluding obstruction. Only 519 (47.9%) tests fully met ATS/ERS spirometry acceptability criteria. Within this group, 5% had obstruction and 6%, restriction on spirometry. In contrast, among all participants (N=1084), 16.8% had obstruction, while 4.5% had restriction. VA showed similar results in all groups after obstruction was excluded. Impaired gas transfer (reduced DL,CO) was identified in less than 50% of restriction identified by either spirometry or VA. Body mass index (BMI) was significantly related to spirometric restriction in all groups. Population estimates of restriction using spirometry or VA varied by spirometric acceptability criteria. Other factors identified as important considerations in the estimation of restrictive ventilatory defect included increased BMI and gas transfer impairment in a relatively smaller proportion of those with spirometric restriction. These insights are important when interpreting population-based physiological data in occupational settings.
Sengul, Aysen Taslak; Sahin, Bunyamin; Celenk, Cetin; Basoglu, Ahmet; Sengul, Bilal
2014-04-01
To assess the increase in lung volume after Nuss surgery in patients with pectus excavatum (PE) by using stereological methods and to evaluate the correlation between the lung volume and spirometry findings. Twenty patients, treated for PE between 2008 and 2010, were evaluated prospectively. They underwent preoperative chest radiography, computed thorax tomography (CTT), and spirometry. Thereafter, the Haller index was calculated for each patient. In the third postoperative month, CTT and spirometry were repeated.Lung volumes and volume fractions were evaluated using CTT images, applying the Cavalieri principle for stereological methods. Then the correlation between the pre- and postoperative values of the lung volumes with spirometry findings was determined. Volumes of the right and left lungs were calculated stereologically, using CTT images. Postoperative volume increase of ∼417.6 ± 747.6 mL was detected. The maximum volume increase was observed in the left lung. In the postoperative period, the total volume increase and the volume increase detected in the left lung were found to be statistically significant (p < 0.05).The preoperative correlation coefficients (r) for forced vital capacity, forced expiratory volume in 1 second, and forced expiratory flow 25 to 75% were 0.67, 0.68, and 0.61, respectively; the postoperative r figures were 0.43, 0.42, and 0.35, respectively. Although there was a strong correlation between the preoperative lung volume and spirometry findings (p < 0.05), no correlation was observed between the postoperative lung volume and spirometry findings (p > 0.05). Postoperative pulmonary volume increase occurs in patients with PE after Nuss surgery. However, postoperative spirometry findings may not reflect morphological improvement because pain restricts thoracic movements. Therefore, in patients with PE, quantitative evaluation of the results of surgical repair is possible using the CTT images through a combination of stereological methods. Georg Thieme Verlag KG Stuttgart · New York.
Impulse Oscillometry and Spirometry Small-Airway Parameters in Mild to Moderate Bronchiectasis.
Guan, Wei-Jie; Yuan, Jing-Jing; Gao, Yong-Hua; Li, Hui-Min; Zheng, Jin-Ping; Chen, Rong-Chang; Zhong, Nan-Shan
2016-11-01
Both impulse oscillometry and spirometry can reflect small-airway disorders. The objective of this work was to investigate the diagnostic value of impulse oscillometry and spirometry small-airway parameters and their correlation with radiology, disease severity, and sputum bacteriology in mild to moderate bronchiectasis (bronchiectasis severity index <9) and to validate these findings in sensitivity analyses (mild bronchiectasis). We recruited 94 subjects with mild to moderate bronchiectasis and 26 healthy subjects. The diagnostic value of small-airway parameters was compared using the receiver operating characteristic curve. Chest high-resolution computed tomography (HRCT), impulse oscillometry measurement, spirometry, and sputum culture were performed. Correlation between small-airway parameters and clinical indices was determined, adjusting for age, sex, body mass index, and smoking history. Sensitivity analyses were repeated when excluding subjects with bronchiectasis severity index ≥9 or HRCT score ≥13. Impulse oscillometry and spirometry small-airway parameters could discriminate mild to moderate bronchiectasis from healthy subjects and correlated significantly with HRCT score and the number of bronchiectatic lobes and the bronchiectasis severity index (all P < .01). Small-airway parameters were more aberrant in subjects with dyshomogeneity and cystic bronchiectasis but were independent of Pseudomonas aeruginosa isolation or the location of predominant bronchiectatic lobes. Spirometry, but not impulse oscillometry, small-airway parameters differed statistically between subjects with isolated peripheral-airway bronchiectasis and those with peripheral plus central-airway bronchiectasis (all P < .01). Subgroup analyses yielded similar findings, except for the lack of correlation between small-airway parameters and clinical parameters in subjects with HRCT score ≤6. Impulse oscillometry and spirometry small-airway parameters have similar diagnostic value in reflecting peripheral-airway disorders and correlate with the HRCT scores, the bronchiectasis severity index, and the number of bronchiectatic lobes in mild to moderate bronchiectasis. Assessment of small-airway parameters should be incorporated in future lung function investigations in bronchiectasis. Copyright © 2016 by Daedalus Enterprises.
Chang, Kuo-Tsai
2007-01-01
This paper investigates electrical transient characteristics of a Rosen-type piezoelectric transformer (PT), including maximum voltages, time constants, energy losses and average powers, and their improvements immediately after turning OFF. A parallel resistor connected to both input terminals of the PT is needed to improve the transient characteristics. An equivalent circuit for the PT is first given. Then, an open-circuit voltage, involving a direct current (DC) component and an alternating current (AC) component, and its related energy losses are derived from the equivalent circuit with initial conditions. Moreover, an AC power control system, including a DC-to-AC resonant inverter, a control switch and electronic instruments, is constructed to determine the electrical characteristics of the OFF transient state. Furthermore, the effects of the parallel resistor on the transient characteristics at different parallel resistances are measured. The advantages of adding the parallel resistor also are discussed. From the measured results, the DC time constant is greatly decreased from 9 to 0.04 ms by a 10 k(omega) parallel resistance under open output.
Reversing-counterpulse repetitive-pulse inductive storage circuit
Honig, Emanuel M.
1987-01-01
A high-power reversing-counterpulse repetitive-pulse inductive storage and transfer circuit includes an opening switch, a main energy storage coil, a counterpulse capacitor and a small inductor. After counterpulsing the opening switch off, the counterpulse capacitor is recharged by the main energy storage coil before the load pulse is initiated. This gives the counterpulse capacitor sufficient energy for the next counterpulse operation, although the polarity of the capacitor's voltage must be reversed before that can occur. By using a current-zero switch as the counterpulse start switch, the capacitor is disconnected from the circuit (with a full charge) when the load pulse is initiated, preventing the capacitor from depleting its energy store by discharging through the load. After the load pulse is terminated by reclosing the main opening switch, the polarity of the counterpulse capacitor voltage is reversed by discharging the capacitor through a small inductor and interrupting the discharge current oscillation at zero current and peak reversed voltage. The circuit enables high-power, high-repetition-rate operation with reusable switches and features total control (pulse-to-pulse) over output pulse initiation, duration, repetition rate, and, to some extent, risetime.
Reversing-counterpulse repetitive-pulse inductive storage circuit
Honig, E.M.
1984-06-05
A high power reversing-counterpulse repetitive-pulse inductive storage and transfer circuit includes an opening switch, a main energy storage coil, a counterpulse capacitor and a small inductor. After counterpulsing the opening switch off, the counterpulse capacitor is recharged by the main energy storage coil before the load pulse is initiated. This gives the counterpulse capacitor sufficient energy for the next counterpulse operation, although the polarity of the capacitor's voltage must be reversed before that can occur. By using a current-zero switch as the counterpulse start switch, the capacitor is disconnected from the circuit (with a full charge) when the load pulse is initiated, preventing the capacitor from depleting its energy store by discharging through the load. After the load pulse is terminated by reclosing the main opening switch, the polarity of the counterpulse capacitor voltage is reversed by discharging the capacitor through a small inductor and interrupting the discharge current oscillation at zero current and peak reversed voltage. The circuit enables high-power, high-repetition-rate operation with reusable switches and features total control (pulse-to-pulse) over output pulse initiation, duration, repetition rate, and, to some extent, risetime.
Epitaxial solar-cell fabrication, phase 2
NASA Technical Reports Server (NTRS)
Daiello, R. V.; Robinson, P. H.; Kressel, H.
1977-01-01
Dichlorosilane (SiH2Cl2) was used as the silicon source material in all of the epitaxial growths. Both n/p/p(+) and p/n/n(+) structures were studied. Correlations were made between the measured profiles and the solar cell parameters, especially cell open-circuit voltage. It was found that in order to obtain consistently high open-circuit voltage, the epitaxial techniques used to grow the surface layer must be altered to obtain very abrupt doping profiles in the vicinity of the junction. With these techniques, it was possible to grow reproducibly both p/n/n(+) and n/p/p(+) solar cell structures having open-circuit voltages in the 610- to 630-mV range, with fill-factors in excess of 0.80 and AM-1 efficiencies of about 13%. Combinations and comparisons of epitaxial and diffused surface layers were also made. Using such surface layers, we found that the blue response of epitaxial cells could be improved, resulting in AM-1 short-circuit current densities of about 30 mA/cm sq. The best cells fabricated in this manner had AM-1 efficiency of 14.1%.
[Quality improvement in workers health surveillance: the spirometry training courses experience].
Innocenti, A; Quercia, A; Roscelli, F
2012-01-01
The spirometry execution during workers health surveillance requires accurate and reproducible spirometric measurements, which should comply with the ATS/ERS guidelines. Low acceptability of spirometric manoeuvres has been reported in health surveillance. This may hamper the validity of the results and affect clinical decision making. Training and refresher courses may produce and maintain good-quality testing, promote the use of spirometric results in clinical practice and enhance the quality of interpretation. We evaluated (with PLATINO score) 239 spirometries from 23 occupational physicians recorded before and after a spirometry refresher course (16 hours) and we verified that only 4 physicians showed a very good improvement and others 4 a good improvement of score, while 9 showed a very slight improvement and 6 instead no improvement. It is worthy of note that in 2012 some spirometers not suitable to UNI EN 26782/2009 were still in use.
Heydari, Abbas; Farzad, Marjan; Ahmadi hosseini, Seyed-hossein
2015-01-01
To examine the effect of incentive spirometry in pulmonary rehabilitation of chronic obstructive pulmonary disease (COPD) patients and compare its efficacy with inspiratory resistive muscle training (IMT) technique. Randomized controlled trial. Thirty patients with COPD, from a general hospital in Mashhad, Iran, were randomly assigned to two study groups. All subjects trained daily in two 15-minute sessions, 4 days a week, for 4 weeks. Respiratory function tests were compared before interventions and at the end of weeks 2 and 4. Both techniques improved the mean values of all respiratory function tests (p≤.01). The IMT technique was more effective to improve MVV and PImax (p≤.05). PEFR was better improved in the incentive spirometry group (p≤.05). There was no significant difference for other spirometric parameters between two groups. Incentive spirometry can be considered as an effective component for pulmonary rehabilitation in COPD patients. © 2013 Association of Rehabilitation Nurses.
46 CFR 169.683 - Overcurrent protection, general.
Code of Federal Regulations, 2013 CFR
2013-10-01
... time delay; (2) Instantaneous short circuit protection; and (3) Repeated opening of the circuit in... above the full-load rating for continuous rated machines or the overload rating for special rated machines. ...
46 CFR 169.683 - Overcurrent protection, general.
Code of Federal Regulations, 2014 CFR
2014-10-01
... time delay; (2) Instantaneous short circuit protection; and (3) Repeated opening of the circuit in... above the full-load rating for continuous rated machines or the overload rating for special rated machines. ...
46 CFR 169.683 - Overcurrent protection, general.
Code of Federal Regulations, 2012 CFR
2012-10-01
... time delay; (2) Instantaneous short circuit protection; and (3) Repeated opening of the circuit in... above the full-load rating for continuous rated machines or the overload rating for special rated machines. ...
Ray, Manas Ranjan; Roychoudhury, Sanghita; Mukherjee, Gopeshwar; Roy, Senjuti; Lahiri, Twisha
2005-01-01
The objective of this study was to examine the respiratory and general health of workers employed in a municipal solid waste (MSW) disposal at an open landfill site in India. Ninety-six landfill workers of Okhla landfill site, Delhi, and 90 controls matched for age, sex, and socioeconomic conditions were enrolled. Health data was obtained from questionnaire surveys, clinical examination and laboratory investigations. Lung function was evaluated by spirometry. Compared with matched controls, landfill workers had significantly higher prevalences of both upper and lower respiratory symptoms, and they suffered more often from diarrhea, fungal infection and ulceration of the skin, burning sensation in the extremities, tingling or numbness, transient loss of memory, and depression. Spirometry revealed impairment of lung function in 62% of the landfill workers compared to 27% of the controls. Sputum cytology showed squamous metaplasia, abundance of inflammatory cells, alveolar macrophages (AM) and siderophages (macrophages with iron deposits), and high elastase enzyme activity in neutrophils and AM of a majority of landfill workers, indicating adverse cellular lung reaction. Hematological profiles of these workers depicted low hemoglobin and erythrocyte levels with high total leukocyte, eosinophil and monocyte counts. Erythrocytes with target cell morphology were abundant in 42% of the landfill workers compared to 10% of the controls. Toxic granulation in neutrophils, an indication of infection and inflammation, was recorded in 94% of the landfill workers and in 49% of the controls. The results demonstrated higher prevalence of respiratory symptoms, inflammation of the airways, lung function decrement and a wide range of general health problems in MSW disposal workers.
Lunardi, Adriana C; Porras, Desiderio C; Barbosa, Renata Cc; Paisani, Denise M; Marques da Silva, Cibele C B; Tanaka, Clarice; Carvalho, Celso R F
2014-03-01
Aging causes physiological and functional changes that impair pulmonary function. Incentive spirometry is widely used for lung expansion, but the effects of volume-oriented incentive spirometry (VIS) versus flow-oriented incentive spirometry (FIS) on chest wall volumes, inspiratory muscle activity, and thoracoabdominal synchrony in the elderly are poorly understood. We compared VIS and FIS in elderly subjects and healthy adult subjects. Sixteen elderly subjects (9 women, mean ± SD age 70.6 ± 3.9 y, mean ± SD body mass index 23.8 ± 2.5 kg/m(2)) and 16 healthy adults (8 women, mean ± age 25.9 ± 4.3 y, mean ± body mass index 23.6 ± 2.4 kg/m(2)) performed quiet breathing, VIS, and FIS in randomized sequence. Chest wall kinematics (via optoelectronic plethysmography) and inspiratory muscle activity (via surface electromyography) were assessed simultaneously. Synchrony between the superior thorax and abdominal motion was calculated (phase angle). In the elderly subjects both types of incentive spirometry increased chest wall volumes similarly, whereas in the healthy adult subjects VIS increased the chest wall volume more than did FIS. FIS and VIS triggered similar lower thoracoabdominal synchrony in the elderly subjects, whereas in the healthy adults FIS induced lower synchrony than did VIS. FIS required more muscle activity in the elderly subjects to create an increase in chest wall volume. Incentive spirometry performance is influenced by age, and the differences between elderly and healthy adults response should be considered in clinical practice.
Dalbak, Lene G; Rognstad, Sture; Melbye, Hasse; Straand, Jørund
2013-06-01
Inhaled glucocorticosteroids (ICS) are first-line anti-inflammatory treatment in asthma, but not in chronic obstructive pulmonary disease (COPD). To restrict ICS use in COPD to cases of severe disease, new terms for reimbursement of drug costs were introduced in Norway in 2006, requiring a diagnosis of COPD to be verified by spirometry. To describe how GPs' diagnoses and treatment of patients who used ICS before 2006 changed after a reassessment of the patients that included spirometry. From the shared electronic patient record system in one group practice, patients ≥ 50 years prescribed ICS (including in combination with long-acting beta2-agonists) during the previous year were identified and invited to a tailored consultation including spirometry to assure the quality of diagnosis and treatment. GPs' diagnoses and ICS prescribing patterns after this reassessment were recorded, retrospectively. Of 164 patients identified, 112 were included. Post-bronchodilator spirometry showed airflow limitation indicating COPD in 55 patients. Of the 57 remaining patients, five had a positive reversibility test. The number of patients diagnosed with asthma increased (from 25 to 62) after the reassessment. A diagnosis of COPD was also more frequently used, whereas fewer patients had other pulmonary diagnoses. ICS was discontinued in 31 patients; 20 with mild to moderate COPD and 11 with normal spirometry. Altered reimbursement terms for ICS changed GPs' diagnostic practice in a way that made the diagnoses better fit with the treatment given, but over-diagnosis of asthma could not be excluded. Spirometry was useful for identifying ICS overuse.
Inter-regional changes in the performance and interpretation of spirometry in Spain: 3E study.
López-Campos, José Luis; Soriano, Joan B; Calle, Myriam
2014-11-01
This report shows the results of a nation-wide survey on spirometry to assess regional differences. Observational cross-sectional study conducted by means of a telephone survey in 805 primary care (PC) and specialized centers (SC) in all regions. The survey contacted technicians in charge of spirometry and consisted of 36 questions related to the test. The results showed major differences between regions. Most centers had 1-2 spirometers. The number of spirometry tests per week ranged from 2 to 8.9 in PC and between 34.3 and 98.3 in SC. Some training had been given in most centers (63.6-100% in PC and 60.0-100% in SC) but not on a regular basis. Most centers used several short-acting bronchodilators for the bronchodilation test, but with insufficient inhalations (2.0-3.8 in PC and 2.0-3.3 in SC) and frequently incorrect waiting time (29.4-83.3% PC and 33.3-87.5% in SC). Daily calibration was not performed in all centers (0-100% in PC and 66.7-100% in SC). Significant inter-regional differences in spirometry quality criteria were observed, with 6 or more criteria met in 9.1-84.6% of PC centers and 37.5-100% in SC. Our results show the current situation of spirometry in primary and specialized care in Spain, highlighting considerable variability and areas for improvement. This information should be considered by health officials to improve the quality and accessibility of such tests. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.
Hydraulically-actuated operating system for an electric circuit breaker
Barkan, Philip; Imam, Imdad
1978-01-01
This hydraulically-actuated operating system comprises a cylinder, a piston movable therein in an opening direction to open a circuit breaker, and an accumulator for supplying pressurized liquid to a piston-actuating space within the cylinder. A normally-closed valve between the accumulator and the actuating space is openable to allow pressurized liquid from the accumulator to flow through the valve into the actuating space to drive the piston in an opening direction. A vent is located hydraulically between the actuating space and the valve for affording communication between said actuating space and a low pressure region. Flow control means is provided for restricting leakage through said vent to a rate that prevents said leakage from substantially detracting from the development of pressure within said actuatng space during the period from initial opening of the valve to the time when said piston has moved through most of its opening stroke. Following such period and while the valve is still open, said flow control means allows effective leakage through said vent. The accumulator has a limited capacity that results in the pressure within said actuating space decaying promptly to a low value as a result of effective leakage through said vent after the piston has moved through a circuit-breaker opening stroke and while the valve is in its open state. Means is provided for resetting the valve to its closed state in response to said pressure decay in the actuating space.
Maze solving automatons for self-healing of open interconnects: Modular add-on for circuit boards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nair, Aswathi; Raghunandan, Karthik; Yaswant, Vaddi
We present the circuit board integration of a self-healing mechanism to repair open faults. The electric field driven mechanism physically restores fractured interconnects in electronic circuits and has the ability to solve mazes. The repair is performed by conductive particles dispersed in an insulating fluid. We demonstrate the integration of the healing module onto printed circuit boards and the ability of maze solving. We model and perform experiments on the influence of the geometry of conductive particles as well as the terminal impedances of the route on the healing efficiency. The typical heal rate is 10 μm/s with healed route havingmore » mean resistance of 8 kΩ across a 200 micron gap and depending on the materials and concentrations used.« less
Performance of conversion efficiency of a crystalline silicon solar cell with base doping density
NASA Astrophysics Data System (ADS)
Sahin, Gokhan; Kerimli, Genber; Barro, Fabe Idrissa; Sane, Moustapha; Alma, Mehmet Hakkı
In this study, we investigate theoretically the electrical parameters of a crystalline silicon solar cell in steady state. Based on a one-dimensional modeling of the cell, the short circuit current density, the open circuit voltage, the shunt and series resistances and the conversion efficiency are calculated, taking into account the base doping density. Either the I-V characteristic, series resistance, shunt resistance and conversion efficiency are determined and studied versus base doping density. The effects applied of base doping density on these parameters have been studied. The aim of this work is to show how short circuit current density, open circuit voltage and parasitic resistances are related to the base doping density and to exhibit the role played by those parasitic resistances on the conversion efficiency of the crystalline silicon solar.
Calcium transport in turtle bladder
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sabatini, S.; Kurtzman, N.A.
1987-12-01
Unidirectional {sup 45}Ca fluxes were measured in the turtle bladder under open-circuit and short-circuit conditions. In the open-circuited state net calcium flux (J{sup net}{sub Ca}) was secretory (serosa to mucosa). Ouabain reversed J{sup net}{sub Ca} to an absorptive flux. Amiloride reduced both fluxes such that J{sup net}{sub Ca} was not significantly different from zero. Removal of mucosal sodium caused net calcium absorption; removal of serosal sodium caused calcium secretion. When bladders were short circuited, J{sup net}{sub Ca} decreased to approximately one-third of control value but remained secretory. When ouabain was added under short-circuit conditions, J{sup net}{sub Ca} was similar inmore » magnitude and direction to ouabain under open-circuited conditions (i.e., absorptive). Tissue {sup 45}Ca content was {approx equal}30-fold lower when the isotope was placed in the mucosal bath, suggesting that the apical membrane is the resistance barrier to calcium transport. The results obtained in this study are best explained by postulating a Ca{sup 2+}-ATPase on the serosa of the turtle bladder epithelium and a sodium-calcium antiporter on the mucosa. In this model, the energy for calcium movement would be supplied, in large part, by the Na{sup +}-K{sup +}-ATPase. By increasing cell sodium, ouabain would decrease the activity of the mucosal sodium-calcium exchanger (or reverse it), uncovering active calcium transport across the serosa.« less
... medicines used to treat asthma fall into two groups: long-term control and quick relief. Long-term control medicines are ... if you should have a spirometry test . Some groups recommend routine spirometry ... Centers for Disease Control and Prevention, HHS Phone: 800-232-4636 (TDD: ...
A retrospective study of two populations to test a simple rule for spirometry.
Ohar, Jill A; Yawn, Barbara P; Ruppel, Gregg L; Donohue, James F
2016-06-04
Chronic lung disease is common and often under-diagnosed. To test a simple rule for conducting spirometry we reviewed spirograms from two populations, occupational medicine evaluations (OME) conducted by Saint Louis and Wake Forest Universities at 3 sites (n = 3260, mean age 64.14 years, 95 % CI 58.94-69.34, 97 % men) and conducted by Wake Forest University preop clinic (POC) at one site (n = 845, mean age 62.10 years, 95 % CI 50.46-73.74, 57 % men). This retrospective review of database information that the first author collected prospectively identified rates, types, sensitivity, specificity and positive and negative predictive value for lung function abnormalities and associated mortality rate found when conducting spirometry based on the 20/40 rule (≥20 years of smoking in those aged ≥ 40 years) in the OME population. To determine the reproducibility of the 20/40 rule for conducting spirometry, the rule was applied to the POC population. A lung function abnormality was found in 74 % of the OME population and 67 % of the POC population. Sensitivity of the rule was 85 % for an obstructive pattern and 77 % for any abnormality on spirometry. Positive and negative predictive values of the rule for a spirometric abnormality were 74 and 55 %, respectively. Patients with an obstructive pattern were at greater risk of coronary heart disease (odds ratio (OR) 1.39 [confidence interval (CI) 1.00-1.93] vs. normal) and death (hazard ratio (HR) 1.53, 95 % CI 1.20-1.84) than subjects with normal spirometry. Restricted spirometry patterns were also associated with greater risk of coronary disease (odds ratio (OR) 1.7 [CI 1.23-2.35]) and death (Hazard ratio 1.40, 95 % CI 1.08-1.72). Smokers (≥ 20 pack years) age ≥ 40 years are at an increased risk for lung function abnormalities and those abnormalities are associated with greater presence of coronary heart disease and increased all-cause mortality. Use of the 20/40 rule could provide a simple method to enhance selection of candidates for spirometry evaluation in the primary care setting.
Scale Up Considerations for Sediment Microbial Fuel Cells
2013-01-01
density calculations were made once WPs stabilized for each system. Linear sweep voltametry was then used on these systems to generate polarization and...power density curves. The systems were allowed to equilibrate under open circuit conditions (about 12 h) before a potential sweep was performed with a...reference. The potential sweep was set to begin at the anode potential under open circuit conditions (20.4 V vs. Ag/AgCl) and was raised to the
Discrete Semiconductor Device Reliability
1988-03-25
array or alphanumeric display. "--" indicates unknown diode count. Voc Open circuit voltage for photovoltaic modules . indicates unknown. Isc Short... circuit current for photovoltaic modules . "--" indicates unknown. Number Tested Quantity of parts under the described test or field conditions for that...information pertaining to electronic systems and parts used therein. The present scope includes integrated circuits , hybrids, discrete semiconductors
42 CFR 37.93 - Approval of spirometry facilities.
Code of Federal Regulations, 2014 CFR
2014-10-01
... EXAMINATIONS SPECIFICATIONS FOR MEDICAL EXAMINATIONS OF COAL MINERS Spirometry Examinations § 37.93 Approval of...-approved facilities must meet the requirements specified in this subpart for the following activities... meet required specifications; collecting the respiratory assessment form; transmitting data to NIOSH...
Design and characterization of a 20 Gbit/s clock recovery circuit
NASA Astrophysics Data System (ADS)
Monteiro, Paulo M.; Matos, J. N.; Gameiro, Atilio M. S.; da Rocha, Jose F.
1995-02-01
In this communication we report the design of a clock recovery circuit produced for the 20 Gbit/s demonstrator of the RACE 2011 project `TRAVEL' of the European Community. The clock recovery circuit is based on an open loop structure using a dielectric resonator narrow bandpass filter with a high quality factor. A detailed electrical characterization of the circuit and also its sensitivity to temperature and detuning variations are presented. The experimental results show that the circuit is a very attractive solution for the forthcoming STM-128 optical links.
Patients with rib fractures: use of incentive spirometry volumes to guide care.
Brown, Sheree D; Walters, Madonna R
2012-01-01
Rib fractures pose significant risk to trauma patients. Effective pain control and the ability to take deep breaths are crucial for optimal recovery, and these are key elements in current clinical guidelines. These guidelines use incentive spirometry volumes along with other assessment values to guide patient care. However, despite current guidelines, nurses do not routinely document inspired respiratory volumes. This article provides trauma nurses with the rationale for documenting and tracking incentive spirometry volumes to improve outcomes for patients with rib fractures. This promotes early detection of respiratory decline and early interventions to improve pain control and pulmonary function.
Yamaguti, Wellington Pereira dos Santos; Sakamoto, Eliana Takahama; Panazzolo, Danilo; Peixoto, Corina da Cunha; Cerri, Giovanni Guido; Albuquerque, André Luis Pereira
2010-01-01
To compare the diaphragmatic mobility of healthy subjects during incentive spirometry with a volume-oriented device, during incentive spirometry with a flow-oriented device, and during diaphragmatic breathing. To compare men and women in terms of diaphragmatic mobility during these three types of breathing exercises. We evaluated the pulmonary function and diaphragmatic mobility of 17 adult healthy volunteers (9 women and 8 men). Diaphragmatic mobility was measured via ultrasound during diaphragmatic breathing and during the use of the two types of incentive spirometers. Diaphragmatic mobility was significantly greater during the use of the volume-oriented incentive spirometer than during the use of the flow-oriented incentive spirometer (70.16 ± 12.83 mm vs. 63.66 ± 10.82 mm; p = 0.02). Diaphragmatic breathing led to a greater diaphragmatic mobility than did the use of the flow-oriented incentive spirometer (69.62 ± 11.83 mm vs. 63.66 ± 10.82 mm; p = 0.02). During all three types of breathing exercises, the women showed a higher mobility/FVC ratio than did the men. Incentive spirometry with a volume-oriented device and diaphragmatic breathing promoted greater diaphragmatic mobility than did incentive spirometry with a flow-oriented device. Women performed better on the three types of breathing exercises than did men.
Kotani, Toshiaki; Akazawa, Tsutomu; Sakuma, Tsuyoshi; Nagaya, Shigeyuki; Sonoda, Masaru; Tanaka, Yuji; Katogi, Takehide; Nemoto, Tetsuharu; Minami, Shohei
2015-06-01
To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. After training, there were significant improvements in vital capacity (VC) from 3.58±0.8 L to 3.74±0.8 L and in %VC from 107.4±10.8 to 112.1±8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7±9.6 mm to 63.4±10.2 mm, from 15.6±6.1 mm to 23.4±10.4 mm, and from 16.3±7.6 mm to 22.0±9.8 mm, respectively. Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period.
Respiratory symptoms necessitating spirometry among soldiers with Iraq/Afghanistan war lung injury.
Szema, Anthony M; Salihi, Walid; Savary, Khalil; Chen, John J
2011-09-01
New-onset asthma rates are higher among US soldiers deployed to Iraq/Afghanistan than stateside, but overall respiratory symptom and spirometry rates among soldiers returning from Iraq/Afghanistan have not yet been addressed. We determined these rates in soldiers deployed to Iraq/Afghanistan versus troops stationed elsewhere. Retrospective review of active-duty soldiers (2004 to 2010) registered at Veterans Affairs Medical Center, Northport, New York, with Long Island/New York City zip codes. Subjects were examined by physicians or physicians' assistants. We counted number of spirometries, which required respiratory symptoms, and the provider was required to submit a diagnosis as part of the request process. Twenty-five percent of 7151 troops went to Iraq/Afghanistan (n = 1816) and 75% went elsewhere (n = 5335), with more smokers in the Iraq/Afghanistan group (16.1% vs 3.3%). Rates of symptoms and spirometry were 14.5% and 1.8%, for Iraq/Afghanistan, versus troops deployed elsewhere, respectively (P < 0.001). Both groups had similar forced expired volume in 1 second/forced vital capacity ratios (78%). New-onset Iraq/Afghanistan war lung injury is common and rates of symptoms leading to a diagnosis requiring spirometry are high. (C)2011The American College of Occupational and Environmental Medicine
Open-loop digital frequency multiplier
NASA Technical Reports Server (NTRS)
Moore, R. C.
1977-01-01
Monostable multivibrator is implemented by using digital integrated circuits where multiplier constant is too large for conventional phase-locked-loop integrated circuit. A 400 Hz clock is generated by divide-by-N counter from 1 Hz timing reference.
1981-02-01
cabinet and the field. The momentary contacts from the switches of the control panel trigger the respective circuits in module I. This circuit then... module (approximately 40 milliamperes at 70-100 detector, filter, threshold circuit and alarm relay. A block volts) Into microwave energy at X-band...advantageous to use different N.C. Terminals. NOTE: If open circuit tamper switch is modulation frequencies on links operating within close prox
Mat Rosly, Maziah; Mat Rosly, Hadi; Hasnan, Nazirah; Davis, Glen M; Husain, Ruby
2017-08-01
Current strategies for increased physical activity and exercise in individuals with spinal cord injury (SCI) face many challenges with regards to maintaining their continuity of participation. Barriers cited often include problems with accessing facilities, mundane, monotonous or boring exercises and expensive equipment that is often not adapted for wheelchair users. To compare the physiological responses and user preferences between conventional heavy-bag boxing against a novel form of video game boxing, known as exergaming boxing. Cross-sectional study. Exercise laboratory setting in a university medical center. Seventeen participants with SCI were recruited, of which sixteen were male and only one female. Their mean age was 35.6±10.2 years. All of them performed a 15-minute physical exercise session of exergaming and heavy-bag boxing in a sitting position. The study assessed physiological responses in terms of oxygen consumption, metabolic equivalent (MET) and energy expenditure between exergaming and heavy-bag boxing derived from open-circuit spirometry. Participants also rated their perceived exertion using Borg's category-ratio ratings of perceived exertion. Both exergaming (MET: 4.3±1.0) and heavy-bag boxing (MET: 4.4±1.0) achieved moderate exercise intensities in these participants with SCI. Paired t-test revealed no significant differences (P>0.05, Cohen's d: 0.02-0.49) in the physiological or perceived exertional responses between the two modalities of boxing. Post session user survey reported all the participants found exergaming boxing more enjoyable. Exergaming boxing, was able to produce equipotent physiological responses as conventional heavy-bag boxing. The intensity of both exercise modalities achieved recommended intensities for health and fitness benefits. Exergaming boxing have the potential to provide an enjoyable, self-competitive environment for moderate-vigorous exercise even at the comfort of their homes.
Physical activity, sedentary behavior, and aerobic capacity in persons with multiple sclerosis.
Motl, Robert W; Sandroff, Brian M; Pilutti, Lara A; Klaren, Rachel E; Baynard, Tracy; Fernhall, Bo
2017-01-15
There is substantial evidence that exercise training improves aerobic capacity among people with multiple sclerosis (MS), but less is known about the associations between physical activity and sedentary behaviors with aerobic capacity. This study examined if objectively-measured moderate-to-vigorous (MVPA) and light (LPA) physical activity and sedentary behavior were associated with peak aerobic capacity (VO 2 peak) measured using an established protocol for conducting a maximal, incremental exercise test in persons with MS. The study involved a cross-sectional, observational study design and included 49 persons with MS. Participants wore an accelerometer around the waist during the waking hours for a 7-day period as a measure of physical activity and sedentary behaviors, and completed a maximal, incremental exercise test on an electronically-braked, computer-controlled cycle ergometer with open-circuit spirometry for measuring VO 2 peak. VO 2 peak was significantly correlated with MVPA (r=0.53, p<0.001) and LPA (r=0.39, p<0.01), but not sedentary behavior (r=-0.12, p=0.44). Linear regression analysis indicated that MVPA (B=0.19, SE B=0.04, β=0.51, p<0.001) and LPA (B=0.02, SE B=0.01, β=0.30, p<0.05), but not sedentary behavior (B=-0.01, SE B=0.01, β=-0.14, p=0.26), explained significant variance in VO 2 peak (R 2 =0.40). We provide the first evidence that MVPA and LPA represent concurrent correlates of VO 2 peak and both could be targeted for improving aerobic capacity in persons with MS. Copyright © 2016 Elsevier B.V. All rights reserved.
Metabolic Rate and Ground Reaction Force During Motorized and Non-Motorized Treadmill Exercise
NASA Technical Reports Server (NTRS)
Everett, Meghan E.; Loehr, James A.; DeWitt, John K.; Laughlin, Mitzi; Lee, Stuart M. C.
2010-01-01
PURPOSE: To measure vertical ground reaction force (vGRF) and oxygen consumption (VO2) at several velocities during exercise using a ground-based version of the ISS treadmill in the M and NM modes. METHODS: Subjects (n = 20) walked or ran at 0.89, 1.34, 1.79, 2.24, 2.68, and 3.12 m/s while VO2 and vGRF data were collected. VO2 was measured using open-circuit spirometry (TrueOne 2400, Parvo-Medics). Data were averaged over the last 2 min of each 5-min stage. vGRF was measured in separate 15-s bouts at 125 Hz using custom-fitted pressure-sensing insoles (F-Scan Sport Sensors, Tekscan, Inc). A repeated-measures ANOVA was used to test for differences in VO2 and vGRF between M and NM and across speeds. Significance was set at P < 0.05. RESULTS: Most subjects were unable to exercise for 5 min at treadmill speeds above 1.79 m/s in the NM mode; however, vGRF data were obtained for all subjects at each speed in both modes. VO2 was approx.40% higher during NM than M exercise across treadmill speeds. vGRF increased with treadmill speed but was not different between modes. CONCLUSION: Higher VO2 with no change in vGRF suggests that the additional metabolic cost associated with NM treadmill exercise is accounted for in the horizontal forces required to move the treadmill belt. Although this may limit the exercise duration at faster speeds, high-intensity NM exercise activates the hamstrings and plantarflexors, which are not specifically targeted or well protected by other in-flight countermeasures.
Kokkinos, Peter; Kaminsky, Leonard A; Arena, Ross; Zhang, Jiajia; Myers, Jonathan
2017-08-15
Impaired cardiorespiratory fitness (CRF) is closely linked to chronic illness and associated with adverse events. The American College of Sports Medicine (ACSM) regression equations (ACSM equations) developed to estimate oxygen uptake have known limitations leading to well-documented overestimation of CRF, especially at higher work rates. Thus, there is a need to explore alternative equations to more accurately predict CRF. We assessed maximal oxygen uptake (VO 2 max) obtained directly by open-circuit spirometry in 7,983 apparently healthy subjects who participated in the Fitness Registry and the Importance of Exercise National Database (FRIEND). We randomly sampled 70% of the participants from each of the following age categories: <40, 40 to 50, 50 to 70, and ≥70 and used the remaining 30% for validation. Multivariable linear regression analysis was applied to identify the most relevant variables and construct the best prediction model for VO 2 max. Treadmill speed and treadmill speed × grade were considered in the final model as predictors of measured VO 2 max and the following equation was generated: VO 2 max in ml O 2 /kg/min = speed (m/min) × (0.17 + fractional grade × 0.79) + 3.5. The FRIEND equation predicted VO 2 max with an overall error >4 times lower than the error associated with the traditional ACSM equations (5.1 ± 18.3% vs 21.4 ± 24.9%, respectively). Overestimation associated with the ACSM equation was accentuated when different protocols were considered separately. In conclusion, The FRIEND equation predicts VO 2 max more precisely than the traditional ACSM equations with an overall error >4 times lower than that associated with the ACSM equations. Published by Elsevier Inc.
Inexpensive system protects megawatt resistance-heating furnace against high-voltage surges
NASA Technical Reports Server (NTRS)
Stearns, E. J.
1971-01-01
Coolant gas extinguishes arcing across the break in a heater element. Air-gap shunt which bypasses high voltage impressed across the circuit prevents damage if the resistance elements break and open the inductive circuit.
Kjeldgaard, Peter; Lykkegaard, Jesper; Spillemose, Heidi; Ulrik, Charlotte Suppli
2017-01-01
Early detection of COPD may reduce the future burden of the disease. We aimed to investigate whether prescreening with a COPD-6 screening device (measuring FEV 1 and FEV 6 ) facilitates early detection of COPD in primary care. In primary care, individuals at high risk of COPD (ie, age ≥35 years, relevant exposure, and at least one respiratory symptom) and no previous diagnosis of obstructive lung disease were examined with a COPD-6 screening device. In prioritized order, the criteria for proceeding to confirmatory spirometry were FEV 1 /FEV 6 <0.7, FEV 1 <80%pred, or clinical suspicion of COPD regardless of test result (medical doctor's [MD] decision). Based on spirometry, including bronchodilator (BD) reversibility test, individuals were classified as COPD (post-BD FEV 1 /FVC <0.70), asthma (ΔFEV 1 ≥0.50 L), or no obstructive lung disease. A total of 2,990 subjects (54% men, mean age 59 years, and mean 28 pack-years) were enrolled, of whom 949 (32%) proceeded from COPD-6 screening to confirmative spirometry based on the following criteria: 510 (54%) FEV 1 /FEV 6 <0.70, 382 (40%) FEV 1 <80%pred, and 57 (6%) MD decision. Following confirmative spirometry, the 949 individuals were diagnosed as having COPD (51%), asthma (3%), and no obstructive lung disease (45%). COPD was diagnosed in 487 (16%) of the enrolled subjects in whom confirmative spirometry was performed in 69% based on FEV 1 /FEV 6 <0.7 and in 29% based on FEV 1 ≤80%pred. Prescreening with the COPD-6 device showed acceptable specificity for the selection of subjects for diagnostic spirometry and is likely to be a useful alternative to current practice in primary care.
Weindler, J; Kiefer, R T
2001-06-01
The study evaluated the impact of the additional imposed work of breathing (WBimp) generated by two different spirometers on postoperative incentive spirometry performance in patients at high risk and moderate risk for postoperative pulmonary complications (PPCs). Additionally, we investigated whether maximal inspiratory pressure (PImax) is an easy estimate of the WBimp imposed by incentive spirometers. Prospective, randomized, single-blind clinical trial. ICU of a university hospital. Thirty male patients were assigned to a group at high risk for PPCs (group A; inspiratory capacity [IC], < 1.6 L) or to a group at moderate risk for PPCs (group B; IC, 1.6 to 2.5 L) after upper-abdominal, thoracic, or two-cavity surgery. On the first or second postoperative day WBimp, IC, and PImax were recorded without spirometers (baseline) and during incentive spirometry with the Mediflo spirometer (Medimex; Hamburg, Germany) (high WBimp) and the Coach spirometer (Kendall; Neustadt, Germany) (low WBimp) using a pneumotachograph. In group A, the baseline and the ICs for both spirometers only differed slightly. In group B, the IC was significantly reduced for the Mediflo (p < 0.05), which imposed a WBimp twice as high as the Coach (p < 0.01). PImax was significantly increased for both the Mediflo and the Coach (p < 0.01). PImax was positively correlated with WBimp (r = 0.8). Incentive spirometers differ considerably in their additional Wbimp with a potential impact on the efficacy of postoperative incentive spirometry performance. PImax might be an easy clinical estimate for the WBimp during incentive spirometry. Incentive spirometers with low WBimp permit increased maximal sustained inspiration and, thus, enhanced incentive spirometry performance, and, therefore, it might be more suitable for use in postoperative respiratory care.
Cheng, Guang-Shing; Campbell, Angela P.; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M.; Englund, Janet A.; Chien, Jason W.; Boeckh, Michael
2016-01-01
BACKGROUND Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplantation (HCT) recipients who are at increased risk for late non-infectious pulmonary complications including bronchiolitis obliterans syndrome (BOS). We evaluated the use of handheld spirometry in this population. METHODS Allogeneic HCT recipients enrolled in a single center observational trial performed weekly spirometry with a handheld spirometer for one year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: pre-transplant, day 80 and 1 year post-transplant. Correlation between the two methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. RESULTS A total of 437 subjects had evaluable pulmonary function tests. Correlation for FEV1 was r=0.954 (p<.0001) at day 80 and r=0.931 (p<.0001) at 1 year when the handheld and laboratory tests were performed within one day of each other. Correlation for handheld FEV6 with laboratory FVC was r=0.914 (p<.0001) at day 80 and r=0.826 (p<.0001) at 1 year. The bias, or the mean difference (handheld minus laboratory) for FEV1 at day 80 and 1 year was −0.13L (−0.63, 0.37) and −0.10L (−0.77, 0.56), respectively. FEV6 showed greater bias at day 80 [−0.51L (−1.44, 0.42)] and 1 year [−0.40L (−1.81, 1.01)]. CONCLUSIONS Handheld spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. PMID:26748162
Sperandio, Evandro Fornias; Arantes, Rodolfo Leite; Matheus, Agatha Caveda; da Silva, Rodrigo Pereira; Lauria, Vinícius Tonon; Romiti, Marcello; Gagliardi, Antônio Ricardo de Toledo; Dourado, Victor Zuniga
2016-01-01
Objective : To determine whether a restrictive pattern on spirometry is associated with the level of physical activity in daily life (PADL), as well as with cardiovascular disease (CVD) risk factors, in asymptomatic adults. Methods : A total of 374 participants (mean age, 41 ± 14 years) underwent spirometry, which included the determination of FVC and FEV1. A restrictive pattern on spirometry was defined as an FEV1/FVC ratio > 0.7 and an FVC < 80% of the predicted value. After conducting demographic, anthropometric, and CVD risk assessments, we evaluated body composition, muscle function, and postural balance, as well as performing cardiopulmonary exercise testing and administering the six-minute walk test. The PADL was quantified with a triaxial accelerometer. Results : A restrictive pattern on spirometry was found in 10% of the subjects. After multivariate logistic regression, adjusted for confounders (PADL and cardiorespiratory fitness), the following variables retained significance (OR; 95% CI) as predictors of a restrictive pattern: systemic arterial hypertension (17.5; 1.65-184.8), smoking (11.6; 1.56-87.5), physical inactivity (8.1; 1.43-46.4), larger center-of-pressure area while standing on a force platform (1.34; 1.05-1.71); and dyslipidemia (1.89; 1.12-1.98). Conclusions : A restrictive pattern on spirometry appears to be common in asymptomatic adults. We found that CVD risk factors, especially systemic arterial hypertension, smoking, and physical inactivity, were directly associated with a restrictive pattern, even when the analysis was adjusted for PADL and cardiorespiratory fitness. Longitudinal studies are needed in order to improve understanding of the etiology of a restrictive pattern as well as to aid in the design of preventive strategies. PMID:26982037
Henry, L; Holmes, S D; Lamberti, J; Halpin, L; Hunt, S; Ad, N
2012-12-01
Early and late outcomes following cardiac surgery may be adversely affected in patients with chronic lung disease (CLD) and the presence of CLD is definition dependent. The purpose of this study was to compare the Society of Thoracic Surgeons (STS) definitions for CLD to the modified American Thoracic Society (ATS)/European Respiratory Society (ERS) definitions in diagnosing and classifying CLD among a cohort of cardiac surgery patients. A prospectively-designed study whereby high risk patients for CLD presenting for non-emergent cardiac surgery and had a history of asthma, a 10 or more pack year history of smoking or a persistent cough were included. All patients underwent spirometry testing within two weeks of surgery. The presence and severity of CLD was coded two times: 1) STS definitions with spirometry; 2) ATS/ERS guidelines. The rate of misclassification was determined using concordance and discordance rates. Sensitivity analysis of the STS spirometry definitions was calculated against the ATS/ERS definitions and respective classifications. The discordant rate for the STS spirometry driven definitions versus the ATS/ERS definitions was 21%. Forty patients (21%) classified as no CLD by the STS spirometry definition were found to have CLD by the ATS/ERS definition. The STS classification had 68% sensitivity (84/124) when identifying any CLD and only 26% sensitivity (14/54) when identifying moderate CLD. The current STS spirometry driven definitions for CLD did not perform as well as the ATS/ERS definitions in diagnosing and classifying the degree of CLD. Consideration should be given to using the ATS/ERS definitions.
Forced oscillometry track sites of airway obstruction in bronchial asthma.
Hafez, Manal Refaat; Abu-Bakr, Samiha Mohamed; Mohamed, Alyaa Abdelnaser
2015-07-01
Spirometry is the most commonly used method for assessment of airway function in bronchial asthma but has several limitations. Forced oscillometry was developed as a patient-friendly test that requires passive cooperation of the patient breathing normally through the mouth. To compare spirometry with forced oscillometry to assess the role of forced oscillometry in the detection of the site of airway obstruction. This case-and-control study included 50 patients with known stable asthma and 50 age- and sex-matched healthy subjects. All participants underwent spirometry (ratio of force expiration volume in 1 second to forced vital capacity, percentage predicted for forced expiration volume in 1 second, percentage predicted for forced vital capacity, percentage predicted for vital capacity, and forced expiratory flow at 25-75%) and forced oscillometry (resistance at 5, 20, and 5-20 Hz). By spirometry, all patients with asthma had airway obstruction, 8% had isolated small airway obstruction, 10% had isolated large airway obstruction, and 82% had large and small airway obstruction. By forced oscillometry, 12% had normal airway resistance, 50% had isolated small airway obstruction with frequency-dependent resistance, and 38% had large and small airway obstruction with frequency-independent resistance. There was significant difference between techniques for the detection of the site of airway obstruction (P = .012). Forced oscillometry indices were negatively correlated with spirometric indices (P < .01). Forced oscillometry as an effortless test, conducted during quiet tidal breathing, and does not alter airway caliber; thus, it can detect normal airway function better than spirometry in patients with asthma. Forced oscillometry detects isolated small airway obstruction better than spirometry in bronchial asthma. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Recombination in polymer-fullerene bulk heterojunction solar cells
NASA Astrophysics Data System (ADS)
Cowan, Sarah R.; Roy, Anshuman; Heeger, Alan J.
2010-12-01
Recombination of photogenerated charge carriers in polymer bulk heterojunction (BHJ) solar cells reduces the short circuit current (Jsc) and the fill factor (FF). Identifying the mechanism of recombination is, therefore, fundamentally important for increasing the power conversion efficiency. Light intensity and temperature-dependent current-voltage measurements on polymer BHJ cells made from a variety of different semiconducting polymers and fullerenes show that the recombination kinetics are voltage dependent and evolve from first-order recombination at short circuit to bimolecular recombination at open circuit as a result of increasing the voltage-dependent charge carrier density in the cell. The “missing 0.3 V” inferred from comparison of the band gaps of the bulk heterojunction materials and the measured open-circuit voltage at room-temperature results from the temperature dependence of the quasi-Fermi levels in the polymer and fullerene domains—a conclusion based on the fundamental statistics of fermions.
Variable cooling circuit for thermoelectric generator and engine and method of control
Prior, Gregory P
2012-10-30
An apparatus is provided that includes an engine, an exhaust system, and a thermoelectric generator (TEG) operatively connected to the exhaust system and configured to allow exhaust gas flow therethrough. A first radiator is operatively connected to the engine. An openable and closable engine valve is configured to open to permit coolant to circulate through the engine and the first radiator when coolant temperature is greater than a predetermined minimum coolant temperature. A first and a second valve are controllable to route cooling fluid from the TEG to the engine through coolant passages under a first set of operating conditions to establish a first cooling circuit, and from the TEG to a second radiator through at least some other coolant passages under a second set of operating conditions to establish a second cooling circuit. A method of controlling a cooling circuit is also provided.
Development of a digital solar simulator based on full-bridge converter
NASA Astrophysics Data System (ADS)
Liu, Chen; Feng, Jian; Liu, Zhilong; Tong, Weichao; Ji, Yibo
2014-02-01
With the development of solar photovoltaic, distribution schemes utilized in power grid had been commonly application, and photovoltaic (PV) inverter is an essential equipment in grid. In this paper, a digital solar simulator based on full-bridge structure is presented. The output characteristic curve of system is electrically similar to silicon solar cells, which can greatly simplify research methods of PV inverter, improve the efficiency of research and development. The proposed simulator consists on a main control board based on TM320F28335, phase-shifted zero-voltage-switching (ZVS) DC-DC full-bridge converter and voltage and current sampling circuit, that allows emulating the voltage-current curve with the open-circuit voltage (Voc) of 900V and the short-circuit current (Isc) of 18A .When the system connected to a PV inverter, the inverter can quickly track from the open-circuit to the maximum power point and keep stability.
Driving CZTS to the SQ Limit: Solving the Open Circuit Voltage Problem
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haight, Richard A.; McCandless, Brian E.; Kummel, Andrew C.
2016-12-15
A key objective of this 3 year research effort was to reduce the open circuit voltage (Voc) deficit, defined as the difference between the absorber band gap and the measured Voc to below 475mV from values at the beginning of this work of 630-730mV. To achieve this reduction, along with the attendant goals of higher Voc and efficiency, detailed studies into the fundamental understanding of existing limitations were undertaken.
Wireless Sensing System Using Open-circuit, Electrically-conductive Spiral-trace Sensor
NASA Technical Reports Server (NTRS)
Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)
2013-01-01
A wireless sensing system includes a sensor made from an electrical conductor shaped to form an open-circuit, electrically-conductive spiral trace having inductance and capacitance. In the presence of a time-varying magnetic field, the sensor resonates to generate a harmonic response having a frequency, amplitude and bandwidth. A magnetic field response recorder wirelessly transmits the time-varying magnetic field to the sensor and wirelessly detects the sensor's response frequency, amplitude and bandwidth.
New equivalent lumped electrical circuit for piezoelectric transformers.
Gonnard, Paul; Schmitt, P M; Brissaud, Michel
2006-04-01
A new equivalent circuit is proposed for a contour-vibration-mode piezoelectric transformer (PT). It is shown that the usual lumped equivalent circuit derived from the conventional Mason approach is not accurate. The proposed circuit, built on experimental measurements, makes an explicit difference between the elastic energies stored respectively on the primary and secondary parts. The experimental and theoretical resonance frequencies with the secondary in open or short circuit are in good agreement as well as the output "voltage-current" characteristic and the optimum efficiency working point. This circuit can be extended to various PT configurations and appears to be a useful tool for modeling electronic devices that integrate piezoelectric transformers.
Single and Concurrent Effects of Endurance and Resistance Training on Pulmonary Function
Khosravi, Maryam; Tayebi, Seyed Morteza; Safari, Hamed
2013-01-01
Objective(s): As not only few evidences but also contradictory results exist with regard to the effects of resistance training (RT) and resistance plus endurance training (ERT) on respiratory system, so the purpose of this research was therefore to study single and concurrent effects of endurance and resistance training on pulmonary function. Materials and Methods: Thirty seven volunteer healthy inactive women were randomly divided into 4 groups: without training as control (C), Endurance Training (ET), RT, and ERT. A spirometry test was taken 24 hrs before and after the training course. The training period (8 weeks, 3 sessions/week) for ET was 20-26 min/session running with 60-80% maximum heart rate (HR max); for RT two circuits/session, 40-60s for each exercise with 60-80% one repetition maximum (1RM), and 1 and 3 minutes active rest between exercises and circuits respectively; and for ERT was in agreement with either ET or RT protocols, but the times of running and circuits were half of ET and RT. Results: ANCOVA showed that ET and ERT increased significantly (P< 0.05) vital capacity (VC), forced vital capacity (FVC), and forced expiratory flows to 25%-75%; ET, RT and ERT increased significantly (P< 0.05) maximum voluntary ventilation (MVV); and only ET increased significantly (P<0.05) peak expiratory flows (PEF); but ET, RT and ERT had no significant effect (P>0.05) on forced expiratory volume in one second (FEV1) and FEV1/FVC ratio. Conclusion: In conclusion, ET combined with RT (ERT) has greater effect on VC, FVC, FEF rating at25%-75%, and also on PEF except MVV, rather than RT, and just ET has greater effect rather than ERT. PMID:24250940
Jeon, Il; Delacou, Clément; Nakagawa, Takafumi; Matsuo, Yutaka
2016-04-20
The application of 58-π-1,4-bis(silylmethyl)[60]fullerenes, C60 (CH2 SiMe2 Ph)(CH2 SiMe2 Ar) (Ar=Ph and 2-methoxylphenyl for SIMEF-1 and SIMEF-2, respectively), in small-molecule organic solar cells with a diketopyrrolopyrrole donor (3,6-bis[5-(benzofuran-2-yl)thiophen-2-yl]-2,5-bis(2-ethylhexyl)pyrrolo[3,4-c]pyrrole-1,4-dione (DPP(TBFu)2 )) is demonstrated. With the 58-π-silylmethyl fullerene acceptor, SIMEF-1, the devices showed the highest efficiency of 4.57 % with an average of 4.10 %. They manifested an improved open-circuit voltage (1.03 V) owing to the high-lying LUMO level of SIMEF-1, while maintaining a high short-circuit density (9.91 mA cm(-2) ) through controlling the crystallinity of DPP by thermal treatment. On the other hand, despite even higher open-circuit voltage (1.05 V), SIMEF-2-based devices showed lower performances of 3.53 %, owing to a low short-circuit current density (8.33 mA cm(-2) ) and fill factor (0.40) arising from the asymmetric structure, which results in a lower mobility and immiscibility. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Gronet, Chris M.; Lewis, Nathan S.; Cogan, George; Gibbons, James
1983-01-01
n-Type Si electrodes in MeOH solvent with 0.2 M (1-hydroxyethyl)ferrocene, 0.5 mM (1-hydroxyethyl)ferricenium, and 1.0 M LiClO4 exhibit air mass 2 conversion efficiencies of 10.1% for optical energy into electricity. We observe open-circuit voltages of 0.53 V and short-circuit quantum efficiencies for electron flow of nearly unity. The fill factor of the cell does not decline significantly with increases in light intensity, indicating substantial reduction in efficiency losses in MeOH solvent compared to previous nonaqueous n-Si systems. Matte etch texturing of the Si surface decreases surface reflectivity and increases photocurrent by 50% compared to shiny, polished Si samples. The high values of the open-circuit voltage observed are consistent with the presence of a thin oxide layer, as in a Schottky metal-insulator-semiconductor device, which yields decreased surface recombination and increased values of open-circuit voltage and short-circuit current. The n-Si system was shown to provide sustained photocurrent at air mass 2 levels (20 mA/cm2) for charge through the interface of >2,000 C/cm2. The n-Si/MeOH system represents a liquid junction cell that has exceeded the 10% barrier for conversion of optical energy into electricity. PMID:16593280
NASA Technical Reports Server (NTRS)
McGrath, William R. (Inventor); Lubecke, Victor M. (Inventor)
1992-01-01
A device for tuning a circuit includes a substrate, a transmission line on the substrate that includes first and second conductors coupled to a circuit to be tuned, and a movable short-circuit for varying the impedance the transmission line presents to the circuit to be tuned. The movable short-circuit includes a dielectric layer disposed atop the transmission line and a distributed shorting element in the form of a conductive member that is configured to be slid along at least a portion of the transmission line atop the dielectric layer. The conductive member is configured to span the first and second conductors of the transmission line and to define at least a first opening that spans the two conductors so that the conductive member includes first and second sections separated by the first opening. The first and second sections of the conductive member combine with the first and second conductors of the transmission line to form first and second low impedance sections of transmission line, and the opening combines with the first and second conductors of the transmission line and the dielectric layer to form a first high impedance section of transmission line intermediate the first and second low impedance sections. Each of the first low impedance section and the first high impedance section have a length along the transmission line of approximately one-quarter wavelength, thus providing a periodic variation of transmission line impedance. That enhances reflection of rf power.
Semiclosed-circuit atmosphere control in a portable recompression chamber
NASA Technical Reports Server (NTRS)
Riegel, P. S.; Caudy, D. W.
1972-01-01
A small portable recompression chamber is described that can be used both to treat a diver for decompression sickness or to transport him to a larger chamber complex. The device can be operated in either open circuit or semiclosed circuit atmospheres, permits two way conversation between patient and attendant, and uses an air injector for circulation of the chamber atmosphere.
Reproducible Operating Margins on a 72800-Device Digital Superconducting Chip (Open Access)
2015-10-28
superconductor digital logic. Keywords: flux trapping, yield, digital Superconductor digital technology offers fundamental advantages over conventional...trapping in the superconductor films can degrade or preclude correct circuit operation. Scaling superconductor technology is now possible due to recent...advances in circuit design embodied in reciprocal quantum logic (RQL) [2, 3] and recent advances in superconductor integrated circuit fabrication, which
Structuring Expert-leaded Medical Protocols for Tele-Medicine Systems
2001-10-25
welfare and health statistics 1991”. Hellenic Republic National Statistical service of Greece, Athens 1994. [3] “ Incentive spirometry pulse...oximetry. O2 therapy in the acute care hospital; spirometry and postural drainage therapy”. Respiratory care 36: 1402-1426, 1991. [4] Economou G.-P
The Role of Incentive Spirometry in Primary Spontaneous Pneumothorax.
Pribadi, Rabbinu R; Singh, Gurmeet; Rumende, Cleopas M
2016-01-01
Pneumothorax is the presence of air in the pleural space. Its management consists of noninvasive and invasive therapies and it is determined based on clinical manifestations, type and size of pneumothorax. We present a case of a patient with diagnosis of primary spontaneous pneumothorax treated with incentive spirometry (noninvasive therapy). A 20 year old man came to respirology clinic with chief complaint of shortness of breath. He was recently diagnosed with left pneumothorax based on previous chest X-ray in another health care facilities and was advised to undergo tube thoracostomy but he refused the procedure. On physical examination, vital signs were normal. Chest X-ray showed 33% of pneumothorax or 1.2 cm. He was asked to perform incentive spirometry therapy at home. During 12 days of therapy, shortness of breath slowly disappeared and on repeated chest X-ray, it showed minimal pneumothorax in the left upper hemithorax. Noninvasive treatment such as incentive spirometry can be considered in patient with minimal symptoms and no signs of life-threatening respiratory distress.
Reversing-counterpulse repetitive-pulse inductive storage circuit
Honig, E.M.
1987-02-10
A high-power reversing-counterpulse repetitive-pulse inductive storage and transfer circuit includes an opening switch, a main energy storage coil, a counterpulse capacitor and a small inductor. After counterpulsing the opening switch off, the counterpulse capacitor is recharged by the main energy storage coil before the load pulse is initiated. This gives the counterpulse capacitor sufficient energy for the next counterpulse operation, although the polarity of the capacitor's voltage must be reversed before that can occur. By using a current-zero switch as the counterpulse start switch, the capacitor is disconnected from the circuit (with a full charge) when the load pulse is initiated, preventing the capacitor from depleting its energy store by discharging through the load. After the load pulse is terminated by reclosing the main opening switch, the polarity of the counterpulse capacitor voltage is reversed by discharging the capacitor through a small inductor and interrupting the discharge current oscillation at zero current and peak reversed voltage. The circuit enables high-power, high-repetition-rate operation with reusable switches and features total control (pulse-to-pulse) over output pulse initiation, duration, repetition rate, and, to some extent, risetime. 10 figs.
Open external circuit for microbial fuel cell sensor to monitor the nitrate in aquatic environment.
Wang, Donglin; Liang, Peng; Jiang, Yong; Liu, Panpan; Miao, Bo; Hao, Wen; Huang, Xia
2018-07-15
This study employed an open external circuit, rather than a closed circuit applied in previous studies, to operate an microbial fuel cell (MFC) sensor for real-time nitrate monitoring, and achieved surprisingly greater sensitivity (4.42 ± 0.3-6.66 ± 0.4 mV/(mg/L)) when the nitrate was at a concentration of 10-40 mg/L, compared to that of the MFC sensor with a closed circuit (0.8 ± 0.05-1.6 ± 0.1 mV/(mg/L)). The MFC sensor operated in open circuit (O-MFC sensor) delivered much more stable performance than that operated in closed circuit (C-MFC sensor) when affected by organic matter (NaAc). The sensitivity of O-MFC sensor was twice that of C-MFC sensor at a low background concentration of organic matter. When organic matter reached a high concentration, the sensitivity of O-MFC sensor remained at an acceptable level, while that of C-MFC sensor dropped to almost zero. Challenged by a combined shock of organic matter and nitrate, O-MFC sensor delivered evident electrical signals for nitrate warning, while C-MFC failed. Another novel feature of this study lies in a new mathematical model to examine the bioanode process of nitrate monitoring. It revealed that lower capacitance of the bioanode in O-MFC was the major contributor to the improved sensitivity of the device. Copyright © 2018 Elsevier B.V. All rights reserved.
Dissipative quantum computing with open quantum walks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinayskiy, Ilya; Petruccione, Francesco
An open quantum walk approach to the implementation of a dissipative quantum computing scheme is presented. The formalism is demonstrated for the example of an open quantum walk implementation of a 3 qubit quantum circuit consisting of 10 gates.
High density electronic circuit and process for making
Morgan, William P.
1999-01-01
High density circuits with posts that protrude beyond one surface of a substrate to provide easy mounting of devices such as integrated circuits. The posts also provide stress relief to accommodate differential thermal expansion. The process allows high interconnect density with fewer alignment restrictions and less wasted circuit area than previous processes. The resulting substrates can be test platforms for die testing and for multi-chip module substrate testing. The test platform can contain active components and emulate realistic operational conditions, replacing shorts/opens net testing.
Majority-voted logic fail-sense circuit
NASA Technical Reports Server (NTRS)
Mclyman, W. T.
1977-01-01
Fail-sense circuit has majority-voted logic component which receives three error voltage signals that are sensed at single point by three error amplifiers. If transistor shorts, only one signal is required to operate; if transistor opens, two signals are required.
[Forced spirometry procedure].
Cortés Aguilera, Antonio Javier
2008-11-01
Forced spirometry consists in a complementary test which is carried out in a health office in a workplace in order to determine the lung capacity of workers exposed to determined professional risks or those susceptible to determined working conditions which could lead to the development of respiratory problems. This test has been developed based on health vigilance laws under Article 22 of the Law for Prevention of Risks in the Workplace and requires that the technician, a nurse in a workplace, who performs it have some knowledge and skills regarding its use, following the norms for forced spirometry set by the Spanish Association for Pneumatology and Thoracic Surgery (SEPAR).
Determinants of peripheral airway function in adults with and without asthma.
Robinson, Paul D; King, Gregory G; Sears, Malcolm R; Hong, Chuen Y; Hancox, Robert J
2017-08-01
Peripheral airway involvement in asthma remains poorly understood. We investigated impulse oscillometry (IOS) measures of peripheral airway function in a population-based birth cohort. Pre- and post-bronchodilator spirometry and IOS measures of respiratory resistance and reactance were measured in 915 participants at age 38 years. Current asthma was associated with impairments in both spirometry and IOS parameters. These impairments were greater in men and in those with childhood persistent asthma. Spirometry and IOS values for those whose asthma was in remission were not different to non-asthmatic participants. There were significant changes in IOS in both asthmatic and non-asthmatic participants after bronchodilator, but between-group differences persisted. Higher BMIs were associated with impairments in IOS but not spirometry. Cumulative tobacco use was associated with spirometric airflow obstruction in both sexes, whereas cannabis use was associated with impairments in IOS in women. Despite higher lifetime exposure, there were few associations between cannabis and IOS in men. Asthma is associated with abnormalities in IOS measures of peripheral airway dysfunction. This association is stronger in men and in those with asthma persisting since childhood. Tobacco and cannabis use are associated with different patterns of spirometry and IOS abnormalities and may affect the bronchial tree at different airway generations with differences in susceptibility between sexes. © 2017 Asian Pacific Society of Respirology.
Akazawa, Tsutomu; Sakuma, Tsuyoshi; Nagaya, Shigeyuki; Sonoda, Masaru; Tanaka, Yuji; Katogi, Takehide; Nemoto, Tetsuharu; Minami, Shohei
2015-01-01
Objective To investigate the effectiveness of incentive spirometry on respiratory motion in healthy subjects using cine breathing magnetic resonance imaging (MRI). Methods Ten non-smoking healthy subjects without any history of respiratory disease were studied. Subjects were asked to perform pulmonary training using incentive spirometry every day for two weeks. To assess the effectiveness of this training, pulmonary function tests and cine breathing MRI were performed before starting pulmonary training and two weeks after its completion. Results After training, there were significant improvements in vital capacity (VC) from 3.58±0.8 L to 3.74±0.8 L and in %VC from 107.4±10.8 to 112.1±8.2. Significant changes were observed in the right diaphragm motion, right chest wall motion, and left chest wall motion, which were increased from 55.7±9.6 mm to 63.4±10.2 mm, from 15.6±6.1 mm to 23.4±10.4 mm, and from 16.3±7.6 mm to 22.0±9.8 mm, respectively. Conclusion Two weeks of training using incentive spirometry provided improvements in pulmonary function and respiratory motion, which suggested that incentive spirometry may be a useful preoperative modality for improving pulmonary function during the perioperative period. PMID:26161341
Seyedmehdi, Seyed Mohammad; Attarchi, Mirsaeed; Yazdanparast, Taraneh; Lakeh, Maziar Moradi
2013-03-01
Quality improvement, standardisation of spirometry testing, and interpretation of results are critically important in the occupational setting. To determine the quality of spirometry tests and pulmonary function changes in two consecutive years among the personnel of an industrial company. This study was performed in an oil refinery in Iran in 2011. Data on 1,004 male personnel were evaluated before and after a training course conducted according to the National Institute for Occupational Safety and Health guidelines. American Thoracic Society/European Respiratory Society guidelines were used for assessment of the acceptability and repeatability criteria. The most common error in the first year of evaluation was forced vital capacity >6 seconds or a 1 second plateau. Acceptability and proper interpretation significantly improved after the course (p<0.05), but repeatability did not change significantly (p>0.05). The results of this study show that the validity and quality of spirometric tests conducted in the studied company in Iran were unacceptable, but these improved significantly after the training intervention. The study demonstrated the lack of a systematic guideline for conducting spirometry and interpreting the results in the occupational setting in Iran, and emphasises the need for a nationwide programme to improve the quality of spirometry tests in this setting.
Handgrip strength is associated with improved spirometry in adolescents
Standl, Marie; Berdel, Dietrich; von Berg, Andrea; Bauer, Carl-Peter; Schikowski, Tamara; Koletzko, Sibylle; Lehmann, Irina; Krämer, Ursula; Heinrich, Joachim; Schulz, Holger
2018-01-01
Introduction Pulmonary rehabilitation, including aerobic exercise and strength training, improves function, such as spirometric indices, in lung disease. However, we found spirometry did not correlate with physical activity (PA) in healthy adolescents (Smith ERJ: 42(4), 2016). To address whether muscle strength did, we measured these adolescents’ handgrip strength and correlated it with spirometry. Methods In 1846 non-smoking, non-asthmatic Germans (age 15.2 years, 47% male), we modeled spirometric indices as functions of handgrip strength by linear regression in each sex, corrected for factors including age, height, and lean body mass. Results Handgrip averaged 35.4 (SD 7.3) kg in boys, 26.6 (4.2) in girls. Spirometric volumes and flows increased linearly with handgrip. In boys each kg handgrip was associated with about 28 mL greater FEV1 and FVC; 60 mL/sec faster PEF; and 38 mL/sec faster FEF2575. Effects were 10–30% smaller in girls (all p<0.0001) and stable when Z-scores for spirometry and grip were modeled, after further correction for environment and/or other exposures, and consistent across stages of puberty. Conclusions Grip strength was associated with spirometry in a cohort of healthy adolescents whose PA was not. Thus, research into PA’s relationship with lung function should consider strength as well as total PA. Strength training may benefit healthy lungs; interventions are needed to prove causality. PMID:29641533
Saadeh, Constantine; Saadeh, Charles; Cross, Blake; Gaylor, Michael; Griffith, Melissa
2015-01-01
This retrospective study was a comparative analysis of sensitivity of impulse oscillometry and spirometry techniques for use in a mixed chronic obstructive pulmonary disease group for assessing disease severity and inhalation therapy. A total of 30 patients with mild-to-moderate chronic obstructive pulmonary disease were monitored by impulse oscillometry, followed by spirometry. Lung function was measured at baseline after bronchodilation and at follow-up (3-18 months). The impulse oscillometry parameters were resistance in the small and large airways at 5 Hz (R5), resistance in the large airways at 15 Hz (R15), and lung reactance (area under the curve X; AX). After the bronchodilator therapy, forced expiratory volume in 1 second (FEV1) readings evaluated by spirometry were unaffected at baseline and at follow-up, while impulse oscillometry detected an immediate improvement in lung function, in terms of AX (p = 0.043). All impulse oscillometry parameters significantly improved at follow-up, with a decrease in AX by 37% (p = 0.0008), R5 by 20% (p = 0.0011), and R15 by 12% (p = 0.0097). Impulse oscillometry parameters demonstrated greater sensitivity compared with spirometry for monitoring reversibility of airway obstruction and the effect of maintenance therapy. Impulse oscillometry may facilitate early treatment dose optimization and personalized medicine for chronic obstructive pulmonary disease patients.
Nonfullerene Tandem Organic Solar Cells with High Open-Circuit Voltage of 1.97 V.
Liu, Wenqing; Li, Shuixing; Huang, Jiang; Yang, Shida; Chen, Jiehuan; Zuo, Lijian; Shi, Minmin; Zhan, Xiaowei; Li, Chang-Zhi; Chen, Hongzheng
2016-11-01
Small-molecule nonfullerene-based tandem organic solar cells (OSCs) are fabricated for the first time by utilizing P3HT:SF(DPPB) 4 and PTB7-Th:IEIC bulk heterojunctions as the front and back subcells, respectively. A power conversion efficiency of 8.48% is achieved with an ultrahigh open-circuit voltage of 1.97 V, which is the highest voltage value reported to date among efficient tandem OSCs. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The effect of diffusion induced lattice stress on the open-circuit voltage in silicon solar cells
NASA Technical Reports Server (NTRS)
Weizer, V. G.; Godlewski, M. P.
1984-01-01
It is demonstrated that diffusion induced stresses in low resistivity silicon solar cells can significantly reduce both the open-circuit voltage and collection efficiency. The degradation mechanism involves stress induced changes in both the minority carrier mobility and the diffusion length. Thermal recovery characteristics indicate that the stresses are relieved at higher temperatures by divacancy flow (silicon self diffusion). The level of residual stress in as-fabricated cells was found to be negligible in the cells tested.
Semiconductor electrolyte photovoltaic energy converter
NASA Technical Reports Server (NTRS)
Anderson, W. W.; Anderson, L. B.
1975-01-01
Feasibility and practicality of a solar cell consisting of a semiconductor surface in contact with an electrolyte are evaluated. Basic components and processes are detailed for photovoltaic energy conversion at the surface of an n-type semiconductor in contact with an electrolyte which is oxidizing to conduction band electrons. Characteristics of single crystal CdS, GaAs, CdSe, CdTe and thin film CdS in contact with aqueous and methanol based electrolytes are studied and open circuit voltages are measured from Mott-Schottky plots and open circuit photo voltages. Quantum efficiencies for short circuit photo currents of a CdS crystal and a 20 micrometer film are shown together with electrical and photovoltaic properties. Highest photon irradiances are observed with the GaAs cell.
Performance of epitaxial back surface field cells
NASA Technical Reports Server (NTRS)
Brandhorst, H. W., Jr.; Baraona, C. R.; Swartz, C. K.
1973-01-01
Epitaxial back surface field structures were formed by depositing a 10 micron thick 10 Omega-cm epitaxial silicon layer onto substrates with resistivities of 0.01, 0.1, 1.0 and 10 Omega-cm. A correlation between cell open-circuit voltage and substrate resistivity was observed and was compared to theory. The cells were also irradiated with 1 MeV electrons to a fluence of 5 X 10 to the 15th power e/cm2. The decrease of cell open-circuit voltage was in excellent agreement with theoretical predictions and the measured short circuit currents were within 2% of the prediction. Calculations are presented of optimum cell performance as functions of epitaxial layer thickness, radiation fluence and substrate diffusion length.
Hansen, D J; Toy, V M; Deininger, R A; Collopy, T K
1983-06-01
Three of the most popular microcomputers, the TRS-80 Model I, the APPLE II+, and the IBM Personal Computer were connected to a spirometer for data acquisition and analysis. Simple programs were written which allow the collection, analysis and storage of the data produced during spirometry. Three examples demonstrate the relative ease for automating spirometers.
Lamar, Joanne
2012-01-01
To address an increase in patient transfers to the intensive care unit because of respiratory distress, a respiratory care bundle utilizing incentive spirometry was developed for a medical general practice unit. This resulted in decreased respiratory complications over 12 months.
NASA Technical Reports Server (NTRS)
Burns, Bradley M. (Inventor); Blalock, Norman N. (Inventor)
2011-01-01
A short circuit protection system includes an inductor, a switch, a voltage sensing circuit, and a controller. The switch and inductor are electrically coupled to be in series with one another. A voltage sensing circuit is coupled across the switch and the inductor. A controller, coupled to the voltage sensing circuit and the switch, opens the switch when a voltage at the output terminal of the inductor transitions from above a threshold voltage to below the threshold voltage. The controller closes the switch when the voltage at the output terminal of the inductor transitions from below the threshold voltage to above the threshold voltage.
Reusable vibration resistant integrated circuit mounting socket
Evans, Craig N.
1995-01-01
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuit lead can be removed from the socket without damage either to the lead or to the socket components.
Portable Cytometry Using Microscale Electronic Sensing
Emaminejad, Sam; Paik, Kee-Hyun; Tabard-Cossa, Vincent; Javanmard, Mehdi
2015-01-01
In this manuscript, we present three different micro-impedance sensing architectures for electronic counting of cells and beads. The first method of sensing is based on using an open circuit sensing electrode integrated in a micro-pore, which measures the shift in potential as a micron-sized particle passes through. Our micro-pore, based on a funnel shaped microchannel, was fabricated in PDMS and was bound covalently to a glass substrate patterned with a gold open circuit electrode. The amplification circuitry was integrated onto a battery-powered custom printed circuit board. The second method is based on a three electrode differential measurement, which opens up the potential of using signal processing techniques to increase signal to noise ratio post measurement. The third architecture uses a contactless sensing approach, which significantly minimizes the cost of the consumable component of the impedance cytometer. We demonstrated proof of concept for the three sensing architectures by measuring the detected signal due to the passage of micron sized beads through the pore. PMID:27647950
A study of short test and charge retention test methods for nickel-cadmium spacecraft cells
NASA Technical Reports Server (NTRS)
Scott, W. R.
1975-01-01
Methods for testing nickel-cadmium cells for internal shorts and charge retention were studied. Included were (a) open circuit voltage decay after a brief charge, (b) open circuit voltage recovery after shorting, and (c) open circuit voltage decay and capacity loss after a full charge. The investigation included consideration of the effects of prior history, of conditioning cells prior to testing, and of various test method variables on the results of the tests. Sensitivity of the tests was calibrated in terms of equivalent external resistance. The results were correlated. It was shown that a large number of variables may affect the results of these tests. It is concluded that the voltage decay after a brief charge and the voltage recovery methods are more sensitive than the charged stand method, and can detect an internal short equivalent to a resistance of about (10,000/C)ohms where "C' is the numerical value of the capacity of the cell in ampere hours.
Electrothermal Feedback and Absorption-Induced Open-Circuit-Voltage Turnover in Solar Cells
NASA Astrophysics Data System (ADS)
Ullbrich, Sascha; Fischer, Axel; Tang, Zheng; Ávila, Jorge; Bolink, Henk J.; Reineke, Sebastian; Vandewal, Koen
2018-05-01
Solar panels easily heat up upon intense solar radiation due to excess energy dissipation of the absorbed photons or by nonradiative recombination of charge carriers. Still, photoinduced self-heating is often ignored when characterizing lab-sized samples. For light-intensity-dependent measurements of the open-circuit voltage (Suns-VO C ), allowing us to characterize the recombination mechanism, sample heating is often not considered, although almost 100% of the absorbed energy is converted into heat. Here, we show that the frequently observed stagnation or even decrease in VOC at increasingly high light intensities can be explained by considering an effective electrothermal feedback between the recombination current and the open-circuit voltage. Our analytical model fully explains the experimental data for various solar-cell technologies, comprising conventional inorganic semiconductors as well as organic and perovskite materials. Furthermore, the model can be exploited to determine the ideality factor, the effective gap, and the temperature rise from a single Suns-VOC measurement at ambient conditions.
Occupational asthma induced by cephalosporins.
Sastre, J; Quirce, S; Novalbos, A; Lluch-Bernal, M; Bombín, C; Umpiérrez, A
1999-05-01
A 20-yr-old pharmaceutical worker who developed attacks of shortness of breath and wheezing 9 months after beginning work on a process in which cefadroxil powder was bottled or encapsulated will be described. Skin test with cefaxodril was negative. Baseline spirometry and methacholine inhalation test were normal. A controlled bronchial challenge test was carried out in a closed-circuit system with assessment of respirable dust concentration. Exposure to cefadroxil powder at a mean concentration of 10 mg x m(-3) for 10 min elicited an isolated immediate asthmatic response, but no response was observed to control challenge with lactose. Single-blind oral challenge test with amoxicillin up to 500 mg was well tolerated, whereas the oral challenge with cephalexin (25 mg) elicited an immediate asthmatic response. This patient had developed occupational asthma caused by inhalation of cefadroxil as confirmed by specific inhalation test. Since she tolerated oral amoxicillin, a synthetic penicillin with the side-chain identical to that of cefadroxil, it seems that she may be sensitized to the dihydrothiazine ring of cephalosporins.
Diong, B; Grainger, J; Goldman, M; Nazeran, H
2009-01-01
The forced oscillation technique offers some advantages over spirometry for assessing pulmonary function. It requires only passive patient cooperation; it also provides data in a form, frequency-dependent impedance, which is very amenable to engineering analysis. In particular, the data can be used to obtain parameter estimates for electric circuit-based models of the respiratory system, which can in turn aid the detection and diagnosis of various diseases/pathologies. In this study, we compare the least-squares error performance of the RIC, extended RIC, augmented RIC, augmented RIC+I(p), DuBois, Nagels and Mead models in fitting 3 sets of impedance data. These data were obtained by pseudorandom noise forced oscillation of healthy subjects, mild asthmatics and more severe asthmatics. We found that the aRIC+I(p) and DuBois models yielded the lowest fitting errors (for the healthy subjects group and the 2 asthmatic patient groups, respectively) without also producing unphysiologically large component estimates.
Development, Integration and Testing of Automated Triggering Circuit for Hybrid DC Circuit Breaker
NASA Astrophysics Data System (ADS)
Kanabar, Deven; Roy, Swati; Dodiya, Chiragkumar; Pradhan, Subrata
2017-04-01
A novel concept of Hybrid DC circuit breaker having combination of mechanical switch and static switch provides arc-less current commutation into the dump resistor during quench in superconducting magnet operation. The triggering of mechanical and static switches in Hybrid DC breaker can be automatized which can effectively reduce the overall current commutation time of hybrid DC circuit breaker and make the operation independent of opening time of mechanical switch. With this view, a dedicated control circuit (auto-triggering circuit) has been developed which can decide the timing and pulse duration for mechanical switch as well as static switch from the operating parameters. This circuit has been tested with dummy parameters and thereafter integrated with the actual test set up of hybrid DC circuit breaker. This paper deals with the conceptual design of the auto-triggering circuit, its control logic and operation. The test results of Hybrid DC circuit breaker using this circuit have also been discussed.
NASA Astrophysics Data System (ADS)
Ma, J.; Liu, Q.
2018-02-01
This paper presents an improved short circuit calculation method, based on pre-computed surface to determine the short circuit current of a distribution system with multiple doubly fed induction generators (DFIGs). The short circuit current, injected into power grid by DFIG, is determined by low voltage ride through (LVRT) control and protection under grid fault. However, the existing methods are difficult to calculate the short circuit current of DFIG in engineering practice due to its complexity. A short circuit calculation method, based on pre-computed surface, was proposed by developing the surface of short circuit current changing with the calculating impedance and the open circuit voltage. And the short circuit currents were derived by taking into account the rotor excitation and crowbar activation time. Finally, the pre-computed surfaces of short circuit current at different time were established, and the procedure of DFIG short circuit calculation considering its LVRT was designed. The correctness of proposed method was verified by simulation.
Fluid circulation determined in the isolated bovine lens.
Candia, Oscar A; Mathias, Richard; Gerometta, Rosana
2012-10-11
In 1997, a theoretical model was developed that predicted the existence of an internal, Na(+)-driven fluid circulation from the poles to the equator of the lens. In the present work, we demonstrate with a novel system that fluid movement can be measured across the polar and equatorial surface areas of isolated cow lenses. We have also determined the effects of ouabain and reduced bath [Na(+)]. Lenses were isolated in a chamber with three compartments separated by two thin O-rings. Each compartment, anterior (A), equatorial (E), and posterior (P), was connected to a vertical capillary graduated in 0.25 μL. Capillary levels were read every 15 minutes. The protocols consisted of 2 hours in either open circuit or short circuit. The effects of ouabain and low-Na(+) solutions were determined under open circuit. In 21 experiments, the E capillary increased at a mean rate of 0.060 μL/min while the A and P levels decreased at rates of 0.044 and 0.037 μL/min, respectively, closely accounting for the increase in E. The first-hour flows under short circuit were approximately 40% larger than those in open-circuit conditions. The first-hour flows were always larger than those during the second hour. Preincubation of lenses with either ouabain or low-[Na(+)] solutions resulted in reduced rates of fluid transport. When KCl was used to replace NaCl, a transitory stimulation of fluid transport occurred. These experiments support that a fluid circulation consistent with the 1997 model is physiologically active.
Chemical Detection using Electrically Open Circuits having no Electrical Connections
NASA Technical Reports Server (NTRS)
Woodward, Stanley E.; Olgesby, Donald M.; Taylor, Bryant D.; Shams, Qamar A.
2008-01-01
This paper presents investigations to date on chemical detection using a recently developed method for designing, powering and interrogating sensors as electrically open circuits having no electrical connections. In lieu of having each sensor from a closed circuit with multiple electrically connected components, an electrically conductive geometric pattern that is powered using oscillating magnetic fields and capable of storing an electric field and a magnetic field without the need of a closed circuit or electrical connections is used. When electrically active, the patterns respond with their own magnetic field whose frequency, amplitude and bandwidth can be correlated with the magnitude of the physical quantities being measured. Preliminary experimental results of using two different detection approaches will be presented. In one method, a thin film of a reactant is deposited on the surface of the open-circuit sensor. Exposure to a specific targeted reactant shifts the resonant frequency of the sensor. In the second method, a coating of conductive material is placed on a thin non-conductive plastic sheet that is placed over the surface of the sensor. There is no physical contact between the sensor and the electrically conductive material. When the conductive material is exposed to a targeted reactant, a chemical reaction occurs that renders the material non-conductive. The change in the material s electrical resistance within the magnetic field of the sensor alters the sensor s response bandwidth and amplitude, allowing detection of the reaction without having the reactants in physical contact with the sensor.
Short circuit in deep brain stimulation.
Samura, Kazuhiro; Miyagi, Yasushi; Okamoto, Tsuyoshi; Hayami, Takehito; Kishimoto, Junji; Katano, Mitsuo; Kamikaseda, Kazufumi
2012-11-01
The authors undertook this study to investigate the incidence, cause, and clinical influence of short circuits in patients treated with deep brain stimulation (DBS). After the incidental identification of a short circuit during routine follow-up, the authors initiated a policy at their institution of routinely evaluating both therapeutic impedance and system impendence at every outpatient DBS follow-up visit, irrespective of the presence of symptoms suggesting possible system malfunction. This study represents a report of their findings after 1 year of this policy. Implanted DBS leads exhibiting short circuits were identified in 7 patients (8.9% of the patients seen for outpatient follow-up examinations during the 12-month study period). The mean duration from DBS lead implantation to the discovery of the short circuit was 64.7 months. The symptoms revealing short circuits included the wearing off of therapeutic effect, apraxia of eyelid opening, or dysarthria in 6 patients with Parkinson disease (PD), and dystonia deterioration in 1 patient with generalized dystonia. All DBS leads with short circuits had been anchored to the cranium using titanium miniplates. Altering electrode settings resulted in clinical improvement in the 2 PD cases in which patients had specific symptoms of short circuits (2.5%) but not in the other 4 cases. The patient with dystonia underwent repositioning and replacement of a lead because the previous lead was located too anteriorly, but did not experience symptom improvement. In contrast to the sudden loss of clinical efficacy of DBS caused by an open circuit, short circuits may arise due to a gradual decrease in impedance, causing the insidious development of neurological symptoms via limited or extended potential fields as well as shortened battery longevity. The incidence of short circuits in DBS may be higher than previously thought, especially in cases in which DBS leads are anchored with miniplates. The circuit impedance of DBS should be routinely checked, even after a long history of DBS therapy, especially in cases of miniplate anchoring.
Comparison between two photovoltaic module models based on transistors
NASA Astrophysics Data System (ADS)
Saint-Eve, Frédéric; Sawicki, Jean-Paul; Petit, Pierre; Maufay, Fabrice; Aillerie, Michel
2018-05-01
The main objective of this paper is to verify the possibility to reduce to a simple electronic circuit with very few components the behavior simulation of an un-shaded photovoltaic (PV) module. Particularly, two models based on well-tried elementary structures, i.e., the Darlington structure in first model and the voltage regulation with programmable Zener diode in the second are analyzed. Specifications extracted from the behavior of a real I-V characteristic of a panel are considered and the principal electrical variables are deduced. The two models are expected to match with open circuit voltage, maximum power point (MPP) and short circuit current, without forgetting realistic current slopes on the both sides of MPP. The robustness is mentioned when irradiance varies and is considered as an additional fundamental property. For both models, two simulations are done to identify influence of some parameters. In the first model, a parameter allowing to adjust current slope on left side of MPP proves to be also important for the calculation of open circuit voltage. Besides this model does not authorize an entirely adjustment of I-V characteristic and MPP moves significantly away from real value when irradiance increases. On the contrary, the second model seems to have only qualities: open circuit voltage is easy to calculate, current slopes are realistic and there is perhaps a good robustness when irradiance variations are simulated by adjusting short circuit current of PV module. We have shown that these two simplified models are expected to make reliable and easier simulations of complex PV architecture integrating many different devices like PV modules or other renewable energy sources and storage capacities coupled in parallel association.
Analysis of recreational closed-circuit rebreather deaths 1998-2010.
Fock, Andrew W
2013-06-01
Since the introduction of recreational closed-circuit rebreathers (CCRs) in 1998, there have been many recorded deaths. Rebreather deaths have been quoted to be as high as 1 in 100 users. Rebreather fatalities between 1998 and 2010 were extracted from the Deeplife rebreather mortality database, and inaccuracies were corrected where known. Rebreather absolute numbers were derived from industry discussions and training agency statistics. Relative numbers and brands were extracted from the Rebreather World website database and a Dutch rebreather survey. Mortality was compared with data from other databases. A fault-tree analysis of rebreathers was compared to that of open-circuit scuba of various configurations. Finally, a risk analysis was applied to the mortality database. The 181 recorded recreational rebreather deaths occurred at about 10 times the rate of deaths amongst open-circuit recreational scuba divers. No particular brand or type of rebreather was over-represented. Closed-circuit rebreathers have a 25-fold increased risk of component failure compared to a manifolded twin-cylinder open-circuit system. This risk can be offset by carrying a redundant 'bailout' system. Two-thirds of fatal dives were associated with a high-risk dive or high-risk behaviour. There are multiple points in the human-machine interface (HMI) during the use of rebreathers that can result in errors that may lead to a fatality. While rebreathers have an intrinsically higher risk of mechanical failure as a result of their complexity, this can be offset by good design incorporating redundancy and by carrying adequate 'bailout' or alternative gas sources for decompression in the event of a failure. Designs that minimize the chances of HMI errors and training that highlights this area may help to minimize fatalities.
Airfoil for a turbine of a gas turbine engine
Liang, George
2010-12-21
An airfoil for a turbine of a gas turbine engine is provided. The airfoil comprises a main body comprising a wall structure defining an inner cavity adapted to receive a cooling air. The wall structure includes a first diffusion region and at least one first metering opening extending from the inner cavity to the first diffusion region. The wall structure further comprises at least one cooling circuit comprising a second diffusion region and at least one second metering opening extending from the first diffusion region to the second diffusion region. The at least one cooling circuit may further comprise at least one third metering opening, at least one third diffusion region and a fourth diffusion region.
High density electronic circuit and process for making
Morgan, W.P.
1999-06-29
High density circuits with posts that protrude beyond one surface of a substrate to provide easy mounting of devices such as integrated circuits are disclosed. The posts also provide stress relief to accommodate differential thermal expansion. The process allows high interconnect density with fewer alignment restrictions and less wasted circuit area than previous processes. The resulting substrates can be test platforms for die testing and for multi-chip module substrate testing. The test platform can contain active components and emulate realistic operational conditions, replacing shorts/opens net testing. 8 figs.
Verde-Remeseiro, Luis; López-Pardo, Estrella; Ruano-Ravina, Alberto; Gude-Sampedro, Francisco; Castro-Calvo, Ramón
2015-01-01
Chronic obstructive pulmonary disease (COPD) is a significant health problem in developed countries. We aimed to estimate the prevalence of COPD in a single Spanish healthcare area. We also aimed to assess if there are any differences in prevalence and spirometry use among primary care services by utilizing already registered information. We designed a cross-sectional study to determine the prevalence of COPD and the performance of spirometries in each primary care service. A total of 8,444 patients were diagnosed with COPD, with a prevalence of 2.6% for individuals older than 39 years. The prevalence increased with age and was much higher in men. Significant heterogeneity was found in the prevalence of COPD and spirometry use among primary care services. COPD was underdiagnosed and there was wide variability in spirometry use in our area. Greater efforts are needed to diagnose COPD in order to improve its clinical outcomes and to refine registries so that they can be used as reliable sources of information. Copyright © 2015 SESPAS. Published by Elsevier Espana. All rights reserved.
Over diagnosis of chronic obstructive pulmonary disease in an underserved patient population.
Ghattas, Christian; Dai, Allen; Gemmel, David J; Awad, Magdi H
2013-01-01
While cross-national studies have documented rates of chronic obstructive pulmonary disease (COPD) misdiagnosis among patients in primary care, US studies are scarce. Studies investigating diagnosis among uninsured patients are lacking. The purpose of this study is to identify patients who are over diagnosed and thus, mistreated, for COPD in a federally qualified health center. A descriptive study was conducted for a retrospective cohort from February 2011 to June 2012. Spirometry was performed by trained personnel following American Thoracic Society recommendations. Patients were referred for spirometry to confirm previous COPD diagnosis or to assess uncontrolled COPD symptoms. Airway obstruction was defined as a forced expiratory volume in the first second of expiration (FEV1) to forced vital capacity ratio less than 0.7. Reversibility was defined as a postbronchodilator increase in FEV1 greater than 200 mL and greater than 12%. Eighty patients treated for a previous diagnosis of COPD (n = 72) or on anticholinergic inhalers (n = 8) with no COPD diagnosis were evaluated. The average age was 52.9 years; 71% were uninsured. Only 17.5% (14/80) of patients reported previous spirometry. Spirometry revealed that 42.5% had no obstruction, 22.5% had reversible obstruction, and 35% had non-reversible obstruction. Symptoms and smoking history are insufficient to diagnose COPD. Prevalence of COPD over diagnosis among uninsured patient populations may be higher than previously reported. Confirming previous COPD diagnosis with spirometry is essential to avoid unnecessary and potentially harmful treatment.
Rollins, K E; Aggarwal, S; Fletcher, A; Knight, A; Rigg, K; Williams, A R; Bhattacharjya, S
2013-05-01
This study aimed to assess the impact of early incentive spirometry on the incidence of chest infection in patients undergoing laparoscopic donor nephrectomy. A retrospective review on all consecutive laparoscopic donor nephrectomies (LDN) performed at a single institution from January 2008 to August 2012 was performed. We performed 84 LDN. Seventy patients had epidural analgesia continued for 48 hours postoperatively and 14 had a combination of spinal followed by oral analgesia. Incentive spirometry was introduced from July 2010 and 45 of the 84 donors used the spirometer as taught, both pre- and postoperatively. We performed 84 LDN; 39 patients did not receive incentive spirometers and had postoperative chest physiotherapy started on postoperative day 1. Of the 45 patients given incentive spirometers, 44 started using their spirometers as taught, after recovery once they were settled in the ward, 1 patient started the exercises the following day. In the group who received no spirometer, 5 patients had a chest infection. In the group of patients who started using their spirometers in the early perioperative period (44/45), no patient developed a chest infection. One patient in this group was excluded from the analysis because he started spirometer exercises on postoperative day 1. This patient did develop a chest infection. Our results suggest that early introduction of incentive spirometry after LDN significantly reduces the incidence of chest infection (P < .05); however, this benefit may be lost if the introduction of spirometry is delayed. Copyright © 2013 Elsevier Inc. All rights reserved.
Donaire, Roberto M; González, Scarlett A; Moya, Ana I; Fierro, Laura T; Brockmann, Pablo V; Caussade, Solange L
2015-01-01
Spirometry is the most used test to evaluate pulmonary function. Guidelines that defined acceptability and repeatability criteria for its implementation and interpretation among preschoolers were published in 2007. Our objective was to quantify the actual compliance with these criteria among pre-school patients. A review was performed on the baseline spirometry measured in patients aged 2 to 5 years in the Pediatric Respiratory Laboratory of the Pontificia Universidad Católica de Chile, who were admitted due to recurrent or persistent coughing or wheezing. Only those results obtained in patients who took the test for the first time were considered. They were analyzed by international standards. A total of 93 spirometry results (mean age 57.4 ± 8.6 months, 48 males) were obtained, of which 44 (47%) met all acceptable criteria, 87 (93%) obtained expiratory time of ≥ 0.5seconds, and 67 (72%) of the patients had an end-expiratory flow of ≤10% from peak flow. The variation in the measurement of forced vital capacity (FVC) and forced expiratory volume in one second (FEV1) was very low (intraclass correlation coefficient > 0.9). It was possible to meet the acceptability and repeatability criteria for spirometry among pre-school children in our Center, which was similar to previous reports. As in older children, this test is fully recommended for pre-school children who require lung function studies. Copyright © 2015. Publicado por Elsevier España, S.L.U.
Dąbrowiecki, Piotr; Mucha, Dominika; Gayer, Anna; Adamkiewicz, Łukasz; Badyda, Artur J
2015-01-01
The Polish Spirometry Day is an initiative aimed at increasing awareness of the causes, symptoms, course, and effects that accompany respiratory diseases, especially asthma and chronic obstructive pulmonary disease (COPD). In 2013, the second edition of the Spirometry Day was held. It gathered 180 medical centers and other institution. The final analysis encompassed a total of 1187 persons from 26 different locations, including rural areas, and smaller and larger city agglomerations. Of this total, 755 persons (63.6 %) completed their spirometry tests for the first time in life. Each person fulfilled a questionnaire regarding the personal information, respiratory diseases, symptoms, lifestyle, and a place of residence. In the total group, 234 (19.7 %) cases of bronchial obstruction were diagnosed. A hundred and thirty four persons with obstruction, among those tested for the first time in life (17.8 %), were unaware of their disease. The lowest values of FEV1 and FEF(1)/FVC, corresponding to the highest percentage of persons with obstruction (27.9 %) were observed in small and medium cities (100,000-500,000 inhabitants). There were differences in the prevalence of obstruction depending on the distance of the place of residence from a busy traffic road. A significant decrease of both spirometric variables was observed among people living in cities above 100,000 inhabitants within a distance lower than 50 m from roads. In general, better spirometry results were observed among inhabitants living more than 150 m from main roads.
Airway hyperreactivity in asymptomatic military personnel.
Morris, Michael J; Schwartz, Darin S; Nohrenberg, Jana L; Dooley, Sean N
2007-11-01
Asthma is frequently diagnosed in military personnel despite strict guidelines that disqualify persons with active disease or a recent history of asthma. It is generally considered incompatible with military service, because of the regular physical training, outdoor training exercises, and deployments to remote locations. The objective of this study was to determine the prevalence of airway hyperreactivity in asymptomatic military personnel, as an estimate of subclinical reactive airway disease. A prospective study of healthy, asymptomatic, military personnel with no previous history of asthma and <1 year on active duty status was conducted. After completion of a screening questionnaire, personnel underwent baseline spirometry with a portable spirometer. Personnel with obstructive indices (based on published guidelines) and matched control subjects participated in an exercise test (1.5-mile run), with pre- and postexercise spirometry. A total of 222 asymptomatic military personnel completed baseline spirometry, and 31 (14%) were found have airway obstruction. A normal matched control group of 31 military personnel and 26 personnel with obstruction performed exercise spirometry. Twenty-three percent of the participants with obstruction demonstrated increased airway hyper-reactivity after exercise, based on a reduction in forced expiratory volume at 1 second, compared with 19% of control subjects. Asymptomatic airway obstruction has a prevalence of 14% in young military personnel. A significant percentage of individuals also have evidence of worsening obstruction during exercise. These data suggest that screening spirometry may identify early reactive airway disease in asymptomatic individuals and should be considered as a method to identify persons predisposed to developing symptomatic asthma.
NASA Technical Reports Server (NTRS)
Jain, Raj K.; Flood, Dennis J.
1990-01-01
Excellent radiation resistance of indium phosphide solar cells makes them a promising candidate for space power applications, but the present high cost of starting substrates may inhibit their large scale use. Thin film indium phosphide cells grown on Si or GaAs substrates have exhibited low efficiencies, because of the generation and propagation of large number of dislocations. Dislocation densities were calculated and its influence on the open circuit voltage, short circuit current, and efficiency of heteroepitaxial indium phosphide cells was studied using the PC-1D. Dislocations act as predominant recombination centers and are required to be controlled by proper transition layers and improved growth techniques. It is shown that heteroepitaxial grown cells could achieve efficiencies in excess of 18 percent AMO by controlling the number of dislocations. The effect of emitter thickness and surface recombination velocity on the cell performance parameters vs. dislocation density is also studied.
Bin, Haijun; Gao, Liang; Zhang, Zhi-Guo; Yang, Yankang; Zhang, Yindong; Zhang, Chunfeng; Chen, Shanshan; Xue, Lingwei; Yang, Changduk; Xiao, Min; Li, Yongfang
2016-01-01
Simutaneously high open circuit voltage and high short circuit current density is a big challenge for achieving high efficiency polymer solar cells due to the excitonic nature of organic semdonductors. Herein, we developed a trialkylsilyl substituted 2D-conjugated polymer with the highest occupied molecular orbital level down-shifted by Si–C bond interaction. The polymer solar cells obtained by pairing this polymer with a non-fullerene acceptor demonstrated a high power conversion efficiency of 11.41% with both high open circuit voltage of 0.94 V and high short circuit current density of 17.32 mA cm−2 benefitted from the complementary absorption of the donor and acceptor, and the high hole transfer efficiency from acceptor to donor although the highest occupied molecular orbital level difference between the donor and acceptor is only 0.11 eV. The results indicate that the alkylsilyl substitution is an effective way in designing high performance conjugated polymer photovoltaic materials. PMID:27905397
Bin, Haijun; Gao, Liang; Zhang, Zhi-Guo; Yang, Yankang; Zhang, Yindong; Zhang, Chunfeng; Chen, Shanshan; Xue, Lingwei; Yang, Changduk; Xiao, Min; Li, Yongfang
2016-12-01
Simutaneously high open circuit voltage and high short circuit current density is a big challenge for achieving high efficiency polymer solar cells due to the excitonic nature of organic semdonductors. Herein, we developed a trialkylsilyl substituted 2D-conjugated polymer with the highest occupied molecular orbital level down-shifted by Si-C bond interaction. The polymer solar cells obtained by pairing this polymer with a non-fullerene acceptor demonstrated a high power conversion efficiency of 11.41% with both high open circuit voltage of 0.94 V and high short circuit current density of 17.32 mA cm -2 benefitted from the complementary absorption of the donor and acceptor, and the high hole transfer efficiency from acceptor to donor although the highest occupied molecular orbital level difference between the donor and acceptor is only 0.11 eV. The results indicate that the alkylsilyl substitution is an effective way in designing high performance conjugated polymer photovoltaic materials.
Polynomial time blackbox identity testers for depth-3 circuits : the field doesn't matter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seshadhri, Comandur; Saxena, Nitin
Let C be a depth-3 circuit with n variables, degree d and top fanin k (called {Sigma}{Pi}{Sigma}(k, d, n) circuits) over base field F. It is a major open problem to design a deterministic polynomial time blackbox algorithm that tests if C is identically zero. Klivans & Spielman (STOC 2001) observed that the problem is open even when k is a constant. This case has been subjected to a serious study over the past few years, starting from the work of Dvir & Shpilka (STOC 2005). We give the first polynomial time blackbox algorithm for this problem. Our algorithm runsmore » in time poly(n)d{sup k}, regardless of the base field. The only field for which polynomial time algorithms were previously known is F = Q (Kayal & Saraf, FOCS 2009, and Saxena & Seshadhri, FOCS 2010). This is the first blackbox algorithm for depth-3 circuits that does not use the rank based approaches of Karnin & Shpilka (CCC 2008). We prove an important tool for the study of depth-3 identities. We design a blackbox polynomial time transformation that reduces the number of variables in a {Sigma}{Pi}{Sigma}(k, d, n) circuit to k variables, but preserves the identity structure. Polynomial identity testing (PIT) is a major open problem in theoretical computer science. The input is an arithmetic circuit that computes a polynomial p(x{sub 1}, x{sub 2},..., x{sub n}) over a base field F. We wish to check if p is the zero polynomial, or in other words, is identically zero. We may be provided with an explicit circuit, or may only have blackbox access. In the latter case, we can only evaluate the polynomial p at various domain points. The main goal is to devise a deterministic blackbox polynomial time algorithm for PIT.« less
NASA Technical Reports Server (NTRS)
Fossum, J. G.; Lindholm, F. A.; Shibib, M. A.
1979-01-01
Experimental data demonstrating the sensitivity of open-circuit voltage to front-surface conditions are presented for a variety of p-n-junction silicon solar cells. Analytical models accounting for the data are defined and supported by additional experiments. The models and the data imply that a) surface recombination significantly limits the open-circuit voltage (and the short-circuit current) of typical silicon cells, and b) energy-bandgap narrowing is important in the manifestation of these limitations. The models suggest modifications in both the structural design and the fabrication processing of the cells that would result in substantial improvements in cell performance. The benefits of one such modification - the addition of a thin thermal silicon-dioxide layer on the front surface - are indicated experimentally.
Mapel, Douglas W; Dalal, Anand A; Johnson, Phaedra T; Becker, Laura K; Hunter, Alyssa Goolsby
2015-01-01
Background In 2011, the traditional Global Initiative for Chronic Obstructive Lung Disease (GOLD) COPD spirometry-based severity classification system was revised to also include exacerbation history and COPD Assessment Test (CAT) and modified Medical Research Council Dyspnea Scale (mMRC) scores. This study examined how COPD patients treated in primary care are reclassified by the new GOLD system compared to the traditional system, and each system’s level of agreement with patient’s or physician’s severity assessments. Methods In this US multicenter cross-sectional study, COPD patients were recruited by 83 primary care practitioners (PCPs) to complete spirometry testing and a survey. Patients were classified by the traditional spirometry-based system (stages 1–4) and under the new system (grades A, B, C, D) using spirometry, exacerbation history, mMRC, and/or CAT results. Concordance between physician and patient-reported severity, spirometry stage, and ABCD grade based on either mMRC or CAT scores was examined. Results Data from 445 patients with spirometry-confirmed COPD were used. As compared to the traditional system, the GOLD mMRC system reclassifies 47% of patients, and GOLD CAT system reclassifies 41%, but the distributions are very different. The GOLD mMRC system resulted in relatively equal distributions by ABCD grade (33%, 22%, 19%, 26%, respectively), but the GOLD CAT system put most into either B or D groups (9%, 45%, 4%, and 42%). The addition of exacerbation history reclassified only 19 additional patients. Agreement between PCPs’ severity rating or their patients’ self-assessment and the new ABCD grade was very poor (κ=0.17 or less). Conclusion As compared to the traditional system, the GOLD 2011 multidimensional system reclassified nearly half of patients, but how they were reclassified varied greatly by whether the mMRC or CAT questionnaire was chosen. Either way, the new system had little correlation with the PCPs or their patients’ impressions about the COPD severity. PMID:26251587
Licskai, Christopher J; Sands, Todd W; Paolatto, Lisa; Nicoletti, Ivan; Ferrone, Madonna
2012-01-01
BACKGROUND: Primary care office spirometry can improve access to testing and concordance between clinical practice and asthma guidelines. Compliance with test quality standards is essential to implementation. OBJECTIVE: To evaluate the quality of spirometry performed onsite in a regional primary care asthma program (RAP) by health care professionals with limited training. METHODS: Asthma educators were trained to perform spirometry during two 2 h workshops and supervised during up to six patient encounters. Quality was analyzed using American Thoracic Society (ATS) 1994 and ATS/European Respiratory Society (ERS) 2003 (ATS/ERS) standards. These results were compared with two regional reference sites: a primary care group practice (Family Medical Centre [FMC], Windsor, Ontario) and a teaching hospital pulmonary function laboratory (London Health Sciences Centre [LHSC], London, Ontario). RESULTS: A total of 12,815 flow-volume loops (FVL) were evaluated: RAP – 1606 FVL in 472 patient sessions; reference sites – FMC 4013 FVL in 573 sessions; and LHSC – 7196 in 1151 sessions. RAP: There were three acceptable FVL in 392 of 472 (83%) sessions, two reproducible FVL according to ATS criteria in 428 of 469 (91%) sessions, and 395 of 469 (84%) according to ATS/ERS criteria. All quality criteria – minimum of three acceptable and two reproducible FVL according to ATS criteria in 361 of 472 (77%) sessions and according to ATS/ERS criteria in 337 of 472 (71%) sessions. RAP met ATS criteria more often than the FMC (388 of 573 [68%]); however, less often than LHSC (1050 of 1151 [91%]; P<0.001). CONCLUSIONS: Health care providers with limited training and experience operating within a simple quality program achieved ATS/ERS quality spirometry in the majority of sessions in a primary care setting. The quality performance approached pulmonary function laboratory standards. PMID:22891184
Mapel, Douglas W; Dalal, Anand A; Johnson, Phaedra T; Becker, Laura K; Hunter, Alyssa Goolsby
2015-01-01
In 2011, the traditional Global Initiative for Chronic Obstructive Lung Disease (GOLD) COPD spirometry-based severity classification system was revised to also include exacerbation history and COPD Assessment Test (CAT) and modified Medical Research Council Dyspnea Scale (mMRC) scores. This study examined how COPD patients treated in primary care are reclassified by the new GOLD system compared to the traditional system, and each system's level of agreement with patient's or physician's severity assessments. In this US multicenter cross-sectional study, COPD patients were recruited by 83 primary care practitioners (PCPs) to complete spirometry testing and a survey. Patients were classified by the traditional spirometry-based system (stages 1-4) and under the new system (grades A, B, C, D) using spirometry, exacerbation history, mMRC, and/or CAT results. Concordance between physician and patient-reported severity, spirometry stage, and ABCD grade based on either mMRC or CAT scores was examined. Data from 445 patients with spirometry-confirmed COPD were used. As compared to the traditional system, the GOLD mMRC system reclassifies 47% of patients, and GOLD CAT system reclassifies 41%, but the distributions are very different. The GOLD mMRC system resulted in relatively equal distributions by ABCD grade (33%, 22%, 19%, 26%, respectively), but the GOLD CAT system put most into either B or D groups (9%, 45%, 4%, and 42%). The addition of exacerbation history reclassified only 19 additional patients. Agreement between PCPs' severity rating or their patients' self-assessment and the new ABCD grade was very poor (κ=0.17 or less). As compared to the traditional system, the GOLD 2011 multidimensional system reclassified nearly half of patients, but how they were reclassified varied greatly by whether the mMRC or CAT questionnaire was chosen. Either way, the new system had little correlation with the PCPs or their patients' impressions about the COPD severity.
High efficiency Cu2ZnSn(S,Se)4 solar cells by applying a double In2S3/CdS emitter.
Kim, Jeehwan; Hiroi, Homare; Todorov, Teodor K; Gunawan, Oki; Kuwahara, Masaru; Gokmen, Tayfun; Nair, Dhruv; Hopstaken, Marinus; Shin, Byungha; Lee, Yun Seog; Wang, Wei; Sugimoto, Hiroki; Mitzi, David B
2014-11-26
High-efficiency Cu2ZnSn(S,Se)4 solar cells are reported by applying In2S3/CdS double emitters. This new structure offers a high doping concentration within the Cu2ZnSn(S,Se)4 solar cells, resulting in a substantial enhancement in open-circuit voltage. The 12.4% device is obtained with a record open-circuit voltage deficit of 593 mV. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
The effect of a defective BSF layer on solar cell open circuit voltage. [Back Surface Field
NASA Technical Reports Server (NTRS)
Weizer, V. G.
1985-01-01
A straightforward analysis of special limiting cases has permitted the determination of the range of possible open circuit voltage losses due to a defective BSF (back surface field) layer. An important result of the analysis is the finding that it is possible to have a fully effective BSF region, regardless of the spatial distribution of the defective areas, as long as the total defective area is reduced below certain limits. Distributed defects were found to be much more harmful than lumped defects.
49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.
Code of Federal Regulations, 2012 CFR
2012-10-01
... THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission...
49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.
Code of Federal Regulations, 2014 CFR
2014-10-01
... THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission...
49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.
Code of Federal Regulations, 2013 CFR
2013-10-01
... THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Rules and Instructions: All Systems Wires and Cables § 236.73 Open-wire transmission...
NASA Astrophysics Data System (ADS)
Nadaud, Kevin; Morini, François; Dahiya, Abhishek S.; Justeau, Camille; Boubenia, Sarah; Rajeev, Kiron P.; Alquier, Daniel; Poulin-Vittrant, Guylaine
2018-02-01
The accurate and precise measurements of voltage and current output generated by a nanogenerator (NG) are crucial to design the rectifying/harvesting circuit and to evaluate correctly the amount of energy provided by a NG. High internal impedance of the NGs (several MΩ) is the main limiting factor for designing circuits to measure the open circuit voltage. In this paper, we present the influence of the characterization circuit used to measure the generated voltage of piezoelectric NGs. The proposed circuit consists of a differential amplifier which permits us to measure the voltage provided by the NG without applying any parasitic bias to it. The proposed circuit is compared to a commercial electrometer and a homemade buffer circuit based on a voltage follower circuit to show its interest. For the proposed double buffer circuit, no asymmetric behavior has been noticed contrary to the measurements made using a simple buffer circuit and a Keithley electrometer. The proposed double buffer circuit is thus suitable to measure the NG voltage in a transparent way, as an ideal voltage probe should do.
Hu, Yuantai; Xue, Huan; Hu, Ting; Hu, Hongping
2008-01-01
This paper studies the performance of an energy harvester with a piezoelectric bimorph (PB) and a real electrochemical battery (ECB), both are connected as an integrated system through a rectified dc-dc converter (DDC). A vibrating PB can scavenge energy from the operating environment by the electromechanical coupling. A DDC can effectively match the optimal output voltage of the harvesting structure to the battery voltage. To raise the output power density of PB, a synchronized switch harvesting inductor (SSHI) is used in parallel with the harvesting structure to reverse the voltage through charge transfer between the output electrodes at the transition moments from closed-to open-circuit. Voltage reversal results in earlier arrival of rectifier conduction because the output voltage phases of any two adjacent closed-circuit states are just opposite each other. In principle, a PB is with a smaller, flexural stiffness under closed-circuit condition than under open-circuit condition. Thus, the PB subjected to longer closed-circuit condition will be easier to be accelerated. A larger flexural velocity makes the PB to deflect with larger amplitude, which implies that more mechanical energy will be converted into an electric one. Nonlinear interface between the vibrating PB and the modulating circuit is analyzed in detail, and the effects of SSHI and DDC on the charging efficiency of the storage battery are researched numerically. It was found that the introduction of a DDC in the modulating circuit and an SSHI in the harvesting structure can raise the charging efficiency by several times.
46 CFR 129.380 - Overcurrent protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... protection must be provided for each ungrounded conductor, to open the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or its insulation. (b) Each conductor of a control, interlock, or indicator circuit, such as a conductor for an instrument...
46 CFR 169.683 - Overcurrent protection, general.
Code of Federal Regulations, 2011 CFR
2011-10-01
... provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation... ungrounded conductors of the circuit simultaneously. (c) Each conductor, including a generator lead and shore...
Cooling circuit for a gas turbine bucket and tip shroud
Willett, Fred Thomas; Itzel, Gary Michael; Stathopoulos, Dimitrios; Plemmons, Larry Wayne; Plemmons, Helen M.; Lewis, Doyle C.
2002-01-01
An open cooling circuit for a gas turbine bucket wherein the bucket has an airfoil portion, and a tip shroud, the cooling circuit including a plurality of radial cooling holes extending through the airfoil portion and communicating with an enlarged internal area within the tip shroud before exiting the tip shroud such that a cooling medium used to cool the airfoil portion is subsequently used to cool the tip shroud.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu Wei; Low, Daniel A.; Parikh, Parag J.
2005-07-15
An important consideration in four-dimensional CT scanning is the selection of a breathing metric for sorting the CT data and modeling internal motion. This study compared two noninvasive breathing metrics, spirometry and abdominal height, against internal air content, used as a surrogate for internal motion. Both metrics were shown to be accurate, but the spirometry showed a stronger and more reproducible relationship than the abdominal height in the lung. The abdominal height was known to be affected by sensor placement and patient positioning while the spirometer exhibited signal drift. By combining these two, a normalization of the drift-free metric tomore » tidal volume may be generated and the overall metric precision may be improved.« less
Effects of AEA Cell-Bypass-Switch Closure on Charged EOS-Aqua NiH2 Cell
NASA Technical Reports Server (NTRS)
Keys, Denney; Rao, Gopalakrishna M.; Sullivan, David; Wannemacher, Harry
2001-01-01
The nominal performance of AEA CBPD under simulated EOS-Aqua/Aura flight hardware configuration has been demonstrated. There is no evidence of cell rupture or excessive heat production during or after CBPD switch activation under simulated high cell impedance (open-circuit cell failure mode). Inadvertent CBPD switch activation with a charged cell (low impedance path) intermittently closes and opens up the switch, therefore the device may or may not provide protection against future open-circuit cell failure. Further testing with switches F01 and F02 may provide clarification. The formation of a continuous low impedance path (a homogeneous low melting point alloy), has been confirmed - which is the expected mode of operation.
46 CFR 183.380 - Overcurrent protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch...
46 CFR 183.380 - Overcurrent protection.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. (b) The grounded conductor of a circuit must not be disconnected by a switch...
30 CFR 75.815 - Disconnect devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... phase-to-phase voltage of the circuit in which they are installed, and for the full-load current of the... explosion-proof enclosures, must be capable of interrupting the full-load current of the circuit or designed and installed to cause the current to be interrupted automatically prior to the opening of the...
30 CFR 75.815 - Disconnect devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... phase-to-phase voltage of the circuit in which they are installed, and for the full-load current of the... explosion-proof enclosures, must be capable of interrupting the full-load current of the circuit or designed and installed to cause the current to be interrupted automatically prior to the opening of the...
The Value of the "Blueprint" Festival
ERIC Educational Resources Information Center
Cawley-Gelling, India; Hyland, Steven; McCarron-Roberts, Connah; Noor, Sufea Mohamad; Morrissey, Ruth
2015-01-01
"Blueprint" was a three-day festival which took place at Tate Liverpool in July 2014 and was organised and produced by Tate Collective Liverpool, as part of "Circuit", a four-year national programme connecting 15-25 year olds to the arts. "Circuit" aims to be open, reflective and critical and bring about…
Employing Si solar cell technology to increase efficiency of ultra-thin Cu(In,Ga)Se2 solar cells.
Vermang, Bart; Wätjen, Jörn Timo; Fjällström, Viktor; Rostvall, Fredrik; Edoff, Marika; Kotipalli, Ratan; Henry, Frederic; Flandre, Denis
2014-10-01
Reducing absorber layer thickness below 500 nm in regular Cu(In,Ga)Se 2 (CIGS) solar cells decreases cell efficiency considerably, as both short-circuit current and open-circuit voltage are reduced because of incomplete absorption and high Mo/CIGS rear interface recombination. In this work, an innovative rear cell design is developed to avoid both effects: a highly reflective rear surface passivation layer with nano-sized local point contact openings is employed to enhance rear internal reflection and decrease the rear surface recombination velocity significantly, as compared with a standard Mo/CIGS rear interface. The formation of nano-sphere shaped precipitates in chemical bath deposition of CdS is used to generate nano-sized point contact openings. Evaporation of MgF 2 coated with a thin atomic layer deposited Al 2 O 3 layer, or direct current magnetron sputtering of Al 2 O 3 are used as rear surface passivation layers. Rear internal reflection is enhanced substantially by the increased thickness of the passivation layer, and also the rear surface recombination velocity is reduced at the Al 2 O 3 /CIGS rear interface. (MgF 2 /)Al 2 O 3 rear surface passivated ultra-thin CIGS solar cells are fabricated, showing an increase in short circuit current and open circuit voltage compared to unpassivated reference cells with equivalent CIGS thickness. Accordingly, average solar cell efficiencies of 13.5% are realized for 385 nm thick CIGS absorber layers, compared with 9.1% efficiency for the corresponding unpassivated reference cells.
Employing Si solar cell technology to increase efficiency of ultra-thin Cu(In,Ga)Se2 solar cells
Vermang, Bart; Wätjen, Jörn Timo; Fjällström, Viktor; Rostvall, Fredrik; Edoff, Marika; Kotipalli, Ratan; Henry, Frederic; Flandre, Denis
2014-01-01
Reducing absorber layer thickness below 500 nm in regular Cu(In,Ga)Se2 (CIGS) solar cells decreases cell efficiency considerably, as both short-circuit current and open-circuit voltage are reduced because of incomplete absorption and high Mo/CIGS rear interface recombination. In this work, an innovative rear cell design is developed to avoid both effects: a highly reflective rear surface passivation layer with nano-sized local point contact openings is employed to enhance rear internal reflection and decrease the rear surface recombination velocity significantly, as compared with a standard Mo/CIGS rear interface. The formation of nano-sphere shaped precipitates in chemical bath deposition of CdS is used to generate nano-sized point contact openings. Evaporation of MgF2 coated with a thin atomic layer deposited Al2O3 layer, or direct current magnetron sputtering of Al2O3 are used as rear surface passivation layers. Rear internal reflection is enhanced substantially by the increased thickness of the passivation layer, and also the rear surface recombination velocity is reduced at the Al2O3/CIGS rear interface. (MgF2/)Al2O3 rear surface passivated ultra-thin CIGS solar cells are fabricated, showing an increase in short circuit current and open circuit voltage compared to unpassivated reference cells with equivalent CIGS thickness. Accordingly, average solar cell efficiencies of 13.5% are realized for 385 nm thick CIGS absorber layers, compared with 9.1% efficiency for the corresponding unpassivated reference cells. PMID:26300619
Fluid Circulation Determined in the Isolated Bovine Lens
Candia, Oscar A.; Mathias, Richard; Gerometta, Rosana
2012-01-01
Purpose. In 1997, a theoretical model was developed that predicted the existence of an internal, Na+-driven fluid circulation from the poles to the equator of the lens. In the present work, we demonstrate with a novel system that fluid movement can be measured across the polar and equatorial surface areas of isolated cow lenses. We have also determined the effects of ouabain and reduced bath [Na+]. Methods. Lenses were isolated in a chamber with three compartments separated by two thin O-rings. Each compartment, anterior (A), equatorial (E), and posterior (P), was connected to a vertical capillary graduated in 0.25 μL. Capillary levels were read every 15 minutes. The protocols consisted of 2 hours in either open circuit or short circuit. The effects of ouabain and low-Na+ solutions were determined under open circuit. Results. In 21 experiments, the E capillary increased at a mean rate of 0.060 μL/min while the A and P levels decreased at rates of 0.044 and 0.037 μL/min, respectively, closely accounting for the increase in E. The first-hour flows under short circuit were approximately 40% larger than those in open-circuit conditions. The first-hour flows were always larger than those during the second hour. Preincubation of lenses with either ouabain or low-[Na+] solutions resulted in reduced rates of fluid transport. When KCl was used to replace NaCl, a transitory stimulation of fluid transport occurred. Conclusions. These experiments support that a fluid circulation consistent with the 1997 model is physiologically active. PMID:22969071
Madec, Morgan; Pecheux, François; Gendrault, Yves; Rosati, Elise; Lallement, Christophe; Haiech, Jacques
2016-10-01
The topic of this article is the development of an open-source automated design framework for synthetic biology, specifically for the design of artificial gene regulatory networks based on a digital approach. In opposition to other tools, GeNeDA is an open-source online software based on existing tools used in microelectronics that have proven their efficiency over the last 30 years. The complete framework is composed of a computation core directly adapted from an Electronic Design Automation tool, input and output interfaces, a library of elementary parts that can be achieved with gene regulatory networks, and an interface with an electrical circuit simulator. Each of these modules is an extension of microelectronics tools and concepts: ODIN II, ABC, the Verilog language, SPICE simulator, and SystemC-AMS. GeNeDA is first validated on a benchmark of several combinatorial circuits. The results highlight the importance of the part library. Then, this framework is used for the design of a sequential circuit including a biological state machine.
NASA Astrophysics Data System (ADS)
Noori, Keian; Konios, Dimitrios; Stylianakis, Minas M.; Kymakis, Emmanuel; Giustino, Feliciano
2016-03-01
Functionalized graphene promises to become a key component of novel solar cell architectures, owing to its versatile ability to act either as transparent conductor, electron acceptor, or buffer layer. In spite of this promise, the solar energy conversion efficiency of graphene-based devices falls short of the performance of competing solution-processable photovoltaic technologies. Here we address the question of the maximum achievable open-circuit voltage of all-organic graphene: polymer solar cells using a combined theoretical/experimental approach, going from the atomic scale level to the device level. Our calculations on very large atomistic models of the graphene/polymer interface indicate that the ideal open-circuit voltage approaches one volt, and that epoxide functional groups can have a dramatic effect on the photovoltage. Our predictions are confirmed by direct measurements on complete devices where we control the concentration of functional groups via chemical reduction. Our findings indicate that the selective removal of epoxide groups and the use of ultradisperse polymers are key to achieving graphene solar cells with improved energy conversion efficiency.
Nanoscale Photosynthesis and the Photophysics of Neural Cells
NASA Astrophysics Data System (ADS)
Greenbaum, Elias; Kuritz, Tanya; Owens, Elizabeth; Lee, Ida; Humayun, Mark
2004-03-01
We extracted and purified integral membrane Photosystem I (PSI) reaction centers from spinach leaves and measured their open and closed circuit photovoltages. The open circuit value is at least 1 V whereas the closed circuit value is at least 0.6 V. A quantitative analysis of the physical properties of PSI reaction centers and voltage-gated ion channels indicates that PSI should be able to trigger the opening of the channels. The cell membrane can be depolarized or hyperpolarized depending on the orientation of the PSI reaction center in the membrane. PSI-proteoliposomes were used as the delivery vehicle. We inserted PSI reaction centers into liposome membranes and, using P700 absorption spectroscopy, demonstrated that the reaction centers retain their functional activity in the liposomes. We have also obtained microscopic evidence that the liposomes are capable of fusing with the membranes of retinoblastoma cells. We report the creation of photoreceptor activity in retinoblastoma cells by PSI reaction centers as indicated by light-induced movement of calcium ions. These results may have application in the field of artificial sight in treating age-related macular degeneration and retinitis pigmentosa.
Rodriguez-Roisin, Roberto; Tetzlaff, Kay; Watz, Henrik; Wouters, Emiel FM; Disse, Bernd; Finnigan, Helen; Magnussen, Helgo; Calverley, Peter MA
2016-01-01
The WISDOM study (NCT00975195) reported a change in lung function following withdrawal of fluticasone propionate in patients with severe to very severe COPD treated with tiotropium and salmeterol. However, little is known about the validity of home-based spirometry measurements of lung function in COPD. Therefore, as part of this study, following suitable training, patients recorded daily home-based spirometry measurements in addition to undergoing periodic in-clinic spirometric testing throughout the study duration. We subsequently determined the validity of home-based spirometry for detecting changes in lung function by comparing in-clinic and home-based forced expiratory volume in 1 second in patients who underwent stepwise fluticasone propionate withdrawal over 12 weeks versus patients remaining on fluticasone propionate for 52 weeks. Bland–Altman analysis of these data confirmed good agreement between in-clinic and home-based measurements, both across all visits and at the individual visits at study weeks 6, 12, 18, and 52. There was a measurable difference between the forced expiratory volume in 1 second values recorded at home and in the clinic (mean difference of −0.05 L), which may be due to suboptimal patient effort in performing unsupervised recordings. However, this difference remained consistent over time. Overall, these data demonstrate that home-based and in-clinic spirometric measurements were equally valid and reliable for assessing lung function in patients with COPD, and suggest that home-based spirometry may be a useful tool to facilitate analysis of changes in lung function on a day-to-day basis. PMID:27578972
Spirometry: a predictor of lung cancer among asbestos workers.
Świątkowska, Beata; Szeszenia-Dąbrowska, Neonila
2017-01-01
The significance of lung function as an independent risk factor for lung cancer remains unclear. The objective of the study is to answer the question if spirometry can identify patients at risk for lung cancer among people occupationally exposed to asbestos dust in the past. In order to identify a group of individuals with the highest risk of lung cancer incidence based on lung function levels of FEV 1 % predicted value, we examined 6882 subjects enrolled in the health surveillance program for asbestos related diseases over the years 2000-2014. We found a total of 110 cases confirmed as primary lung cancer. Using Cox's proportional hazards model after adjustment for age, gender, number of cigarettes, duration of smoking and cumulative asbestos exposure, we estimated that compared with the subjects with FEV 1 ≥90% pred, the HR of lung cancer was 1.40 (95%CI: 0.94-2.08) for the subjects with FEV 1 less than 90% and 1.95 (HR = 1.86; 95%CI: 1.12-3.08) for those with FEV 1 less than 70%. In addition, probability of the occurrence of lung cancer for FEV 1 <90% of the predicted value was HR = 2.19 (95%CI: 1.04-4.61) in the subjects whose time since spirometry and cancer diagnosis was three years or less. The results strongly support the hypothesis that spirometry can identify patients at a risk of lung cancer development. Regular spirometry should be offered to all patients with a history of asbestos exposure, at least once every three years.
Cukic, Vesna
2012-01-01
Introduction: Nowadays an increasing number of lung resections are being done because of the rising prevalence of lung cancer that occurs mainly in patients with limited lung function, what is caused by common etiologic factor - smoking cigarettes. Loss of lung tissue in such patients can worsen much the postoperative pulmonary function. So it is necessary to asses the postoperative pulmonary function especially after maximal resection, i.e. pneumonectomy. Objective: To check over the accuracy of preoperative prognosis of postoperative lung function after pneumonectomy using spirometry and lung perfusion scinigraphy. Material and methods: The study was done on 17 patients operated at the Clinic for thoracic surgery, who were treated previously at the Clinic for Pulmonary Diseases “Podhrastovi” in the period from 01. 12. 2008. to 01. 06. 2011. Postoperative pulmonary function expressed as ppoFEV1 (predicted postoperative forced expiratory volume in one second) was prognosticated preoperatively using spirometry, i.e.. simple calculation according to the number of the pulmonary segments to be removed and perfusion lung scintigraphy. Results: There is no significant deviation of postoperative achieved values of FEV1 from predicted ones obtained by both methods, and there is no significant differences between predicted values (ppoFEV1) obtained by spirometry and perfusion scintigraphy. Conclusion: It is necessary to asses the postoperative pulmonary function before lung resection to avoid postoperative respiratory failure and other cardiopulmonary complications. It is absolutely necessary for pneumonectomy, i.e.. maximal pulmonary resection. It can be done with great possibility using spirometry or perfusion lung scintigraphy. PMID:23378687
El Attar, Mohamed Nour; Hadj Mabrouk, Khaoula; Ben Abdelaziz, Ahmed; Abdelghani, Ahmed; Bousarssar, Mohamed; Limam, Khélifa; Maatoug, Chiraz; Bouslah, Hmida; Charrada, Ameur; Rouatbi, Sonia; Ben Saad, Helmi
2014-01-01
Tunisian pulmonary functional laboratories accept the default settings for reference equations (European Respiratory Society/European Community for Steel and Coal (ERS/ECSC1983) offered by the manufacturer even though adult Tunisian reference equations (Tunisian1995) are available. To compare the spirometric profile of Tunisian subjects, according to the two reference equations. Spirometric data were recorded from 1192 consecutive spirometry procedures in adults aged 18-60 years. Reference values and lower limits of normality (LLN) were calculated using the two reference equations. Applied definitions: large airway obstructive ventilatory defect (LAOVD): ratio between the 1st second expiratory volume and forced vital capacity (FEV1/FVC) < LLN. Small AOVD (SAOVD): FEV1/FVC > LLN and FVC > LLN and maximal midexpiratory flow < LLN. Tendency through a restrictive ventilatory defect (TRVD): FEV1 and FVC < LLN. The spirometric profile, according the two reference equations, was determined. Using Tunisian1995 reference equations, 34%, 7%, 37% and 19% of spirometry records were interpreted as normal, and as having, LAOVD, SAOVD and TRVD, respectively. Using ERS/ECSC1983 reference equations, 85%, 3%, 9% and 2% of spirometry records were interpreted as normal, and as having, LAOVD, SAOVD and TRVD, respectively. Using the ERS/ECSC1983 reference equations, misclassification was worse for LAOVD, for SAOVD and for TRVD, respectively, 68%, 94% and 89%. Our results showed that the use of the old Caucasian reference equations resulted in misinterpretation of spirometry data in a significant proportion of subjects. This could result in inappropriate diagnosis and/or management.
Pulmonary function in adolescents with ataxia telangiectasia.
McGrath-Morrow, Sharon; Lefton-Greif, Maureen; Rosquist, Karen; Crawford, Thomas; Kelly, Amber; Zeitlin, Pamela; Carson, Kathryn A; Lederman, Howard M
2008-01-01
Pulmonary complications are common in adolescents with ataxia telangiectasia (A-T), however objective measurements of lung function may be difficult to obtain because of underlying bulbar weakness, tremors, and difficulty coordinating voluntary respiratory maneuvers. To increase the reliability of pulmonary testing, minor adjustments were made to stabilize the head and to minimize leaks in the system. Fifteen A-T adolescents completed lung volume measurements by helium dilution. To assess for reproducibility of spirometry testing, 10 A-T adolescents performed spirometry on three separate occasions. Total lung capacity (TLC) was normal or just mildly decreased in 12/15 adolescents tested. TLC correlated positively with functional residual capacity (FRC), a measurement independent of patient effort (R2=0.71). The majority of individuals had residual volumes (RV) greater than 120% predicted (10/15) and slow vital capacities (VC) less than 70% predicted (9/15). By spirometry, force vital capacity (FVC) and forced expiratory volume in 1 sec (FEV1) values were reproducible in the 10 individuals who underwent testing on three separate occasions (R=0.97 and 0.96 respectively). Seven of the 10 adolescents had FEV1/FVC ratios>90%. Lung volume measurements from A-T adolescents revealed near normal TLC values with increased RV and decreased VC values. These findings indicate a decreased ability to expire to residual volume rather then a restrictive defect. Spirometry was also found to be reproducible in A-T adolescents suggesting that spirometry testing may be useful for tracking changes in pulmonary function over time in this population. Copyright (c) 2007 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Sugaya, Takeyoshi; Tayagaki, Takeshi; Aihara, Taketo; Makita, Kikuo; Oshima, Ryuji; Mizuno, Hidenori; Nagato, Yuki; Nakamoto, Takashi; Okano, Yoshinobu
2018-05-01
We report high-quality dual-junction GaAs solar cells grown using solid-source molecular beam epitaxy and their application to smart stacked III–V//Si quadruple-junction solar cells with a two-terminal configuration for the first time. A high open-circuit voltage of 2.94 eV was obtained in an InGaP/GaAs/GaAs triple-junction top cell that was stacked to a Si bottom cell. The short-circuit current density of a smart stacked InGaP/GaAs/GaAs//Si solar cell was in good agreement with that estimated from external quantum efficiency measurements. An efficiency of 18.5% with a high open-circuit voltage of 3.3 V was obtained in InGaP/GaAs/GaAs//Si two-terminal solar cells.
Candle Soot-Driven Performance Enhancement in Pyroelectric Energy Conversion
NASA Astrophysics Data System (ADS)
Azad, Puneet; Singh, V. P.; Vaish, Rahul
2018-05-01
We observed substantial enhancement in pyroelectric output with the help of candle soot coating on the surface of lead zirconate titanate (PZT). Candle soot of varying thicknesses was coated by directly exposing pyroelectric material to the candle flame. The open-circuit pyroelectric voltage and closed-circuit pyroelectric current were recorded while applying infrared heating across the uncoated and candle soot-coated samples for different heating and cooling cycles. In comparison to the uncoated sample, the maximum open-circuit voltage improves seven times for the candle soot-coated sample and electric current increases by eight times across a resistance of 10Å. Moreover, the harvested energy is enhanced by 50 times for candle soot-coated sample. Results indicate that candle soot coating is an effective and economic method to improve infrared sensing performance of pyroelectric materials.
European Non-Dissipative Bypass Switch For Li-Ion Batteries And Prospective
NASA Astrophysics Data System (ADS)
Pasquier, E.; Castric, AF.; Mosset, E.; Chandeneau, A.
2011-10-01
Li-ion batteries are made of cells or modules connected in series. In case one may be too weak or failed, it becomes necessary to remove it from the serial circuit. This is the by-pass operation which provides overcharge/open-circuitprotection,limitation of possible constraints linked to over- discharge/reversal/"self-short" and avoid to jeopardize rest of battery. One system is particularly adapted to Space Li-ion batteries: the "make before break" Single Pole Double Throw (SPDT) switch which avoids open- circuit on power circuit when correctly activated. This paper presents the component constraints, the development in the frame of ESA Artès 3 program up to its qualification, as well as the motorization approach linked to ECSS-E-30 (mechanical - Part 3: Mechanisms) and future opportunities of such system.
Open-channel integrating-type flow meter
Koopman, K.C.
1971-01-01
A relatively inexpensive meter for measuring cumulative flow in open channels with a rated control,. called a "totalizer", was developed. It translates the nonlinear function of gage height to flow by use of a cam and a float. A variable resistance element in an electronic circuit is controlled by the float so that the electron flow in the circuit corresponds to the flow of water. The flow of electricity causes electroplating of an electrode with silver. The amount of silver deposited is proportionate to the flow of water. The total flow of water is determined by removing the silver from the electrode at a fixed rate with ·an electronic device and recording the time for removal with a counter. The circuit is designed so that the ,resultant reading on the counter is in acre-feet of water.
Circuit breaker lock out assembly
Gordy, W.T.
1983-05-18
A lock out assembly for a circuit breaker which consists of a generally step-shaped unitary base with an aperture in the small portion of the step-shaped base and a roughly S shaped retaining pin which loops through the large portion of the step-shaped base. The lock out assembly is adapted to fit over a circuit breaker with the handle switch projecting through the aperture, and the retaining pin projecting into an opening of the handle switch, preventing removal.
Circuit breaker lock out assembly
Gordy, Wade T.
1984-01-01
A lock out assembly for a circuit breaker which consists of a generally step-shaped unitary base with an aperture in the small portion of the step-shaped base and a roughly "S" shaped retaining pin which loops through the large portion of the step-shaped base. The lock out assembly is adapted to fit over a circuit breaker with the handle switch projecting through the aperture, and the retaining pin projecting into an opening of the handle switch, preventing removal.
Solution-Processed Ag Nanowires + PEDOT:PSS Hybrid Electrode for Cu(In,Ga)Se₂ Thin-Film Solar Cells.
Shin, Donghyeop; Kim, Taegeon; Ahn, Byung Tae; Han, Seung Min
2015-06-24
To reduce the cost of the Cu(In,Ga)Se2 (CIGS) solar cells while maximizing the efficiency, we report the use of an Ag nanowires (NWs) + poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) ( PSS) hybrid transparent electrode, which was deposited using all-solution-processed, low-cost, scalable methods. This is the first demonstration of an Ag NWs + PSS transparent electrode applied to CIGS solar cells. The spin-coated 10-nm-thick PSS conducting polymer layer in our hybrid electrode functioned as a filler of empty space of an electrostatically sprayed Ag NW network. Coating of PSS on the Ag NW network resulted in an increase in the short-circuit current from 15.4 to 26.5 mA/cm(2), but the open-circuit voltage and shunt resistance still needed to be improved. The limited open-circuit voltage was found to be due to interfacial recombination that is due to the ineffective hole-blocking ability of the CdS film. To suppress the interfacial recombination between Ag NWs and the CdS film, a Zn(S,O,OH) film was introduced as a hole-blocking layer between the CdS film and Ag NW network. The open-circuit voltage of the cell sharply improved from 0.35 to 0.6 V, which resulted in the best cell efficiency of 11.6%.
Open Circuit Resonant Sensors for Composite Damage Detection and Diagnosis
NASA Technical Reports Server (NTRS)
Mielnik, John J., Jr.
2011-01-01
Under the Integrated Vehicle Health Management (IVHM) program work was begun to investigate the feasibility of sensor systems for detecting and diagnosing damage to aircraft composite structures and materials. Specific interest for this study was in damage initiated by environmental storm hazards and the direct effect of lightning strikes on the material structures of a composite aircraft in flight. A series of open circuit resonant sensors was designed, fabricated, characterized, and determined to be a potentially viable means for damage detection and diagnosis of composite materials. The results of this research and development effort are documented in this report.
Voc enhancement of a solar cell with doped Li+-PbS as the active layer
NASA Astrophysics Data System (ADS)
Chávez Portillo, M.; Alvarado Pulido, J.; Gallardo Hernández, S.; Soto Cruz, B. S.; Alcántara Iniesta, S.; Gutiérrez Pérez, R.; Portillo Moreno, O.
2018-06-01
In this report, we investigate the fabrication of solar cells obtained by chemical bath technique, based on CdS as window layer and PbS and PbS-Li+-doped as the active layer. We report open-circuit-voltage Voc values of ∼392 meV for PbS and ∼630 meV for PbSLi+-doped, a remarkable enhanced in the open circuit voltage is shown for solar cells with doped active layer. Li+ ion passivate the dangling bonds in PbS-metal layer interface in consequence reducing the recombination centers.
49 CFR 236.52 - Relayed cut-section.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Relayed cut-section. 236.52 Section 236.52...: All Systems Track Circuits § 236.52 Relayed cut-section. Where relayed cut-section is used in... shall be open and the track circuit shunted when the track relay at such cut-section is in deenergized...
49 CFR 236.52 - Relayed cut-section.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Relayed cut-section. 236.52 Section 236.52...: All Systems Track Circuits § 236.52 Relayed cut-section. Where relayed cut-section is used in... shall be open and the track circuit shunted when the track relay at such cut-section is in deenergized...
Turkish Students' Conceptions about the Simple Electric Circuits
ERIC Educational Resources Information Center
Cepni, Salih; Keles, Esra
2006-01-01
In this study, the Turkish students' understanding level of electric circuits consisting of two bulbs and one battery was investigated by using open-ended questions. Two-hundred fifty students, whose ages range from 11 to 22, were chosen from five different groups at primary, secondary and university levels in Trabzon in Turkey. In analyzing…
10 CFR 431.322 - Definitions concerning metal halide lamp ballasts and fixtures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... main functions. Ballast means a device used with an electric discharge lamp to obtain necessary circuit... mode. Electronic ballast means a device that uses semiconductors as the primary means to control lamp..., and does not generally contain an igniter but instead starts lamps with high ballast open circuit...
10 CFR 431.322 - Definitions concerning metal halide lamp ballasts and fixtures.
Code of Federal Regulations, 2011 CFR
2011-01-01
... main functions. Ballast means a device used with an electric discharge lamp to obtain necessary circuit... purpose of controlling the ballast and putting the ballast in standby mode. Electronic ballast means a... instead starts lamps with high ballast open circuit voltage. Pulse-start metal halide ballast means an...
10 CFR 431.322 - Definitions concerning metal halide lamp ballasts and fixtures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... main functions. Ballast means a device used with an electric discharge lamp to obtain necessary circuit... mode. Electronic ballast means a device that uses semiconductors as the primary means to control lamp..., and does not generally contain an igniter but instead starts lamps with high ballast open circuit...
10 CFR 431.322 - Definitions concerning metal halide lamp ballasts and fixtures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... main functions. Ballast means a device used with an electric discharge lamp to obtain necessary circuit... mode. Electronic ballast means a device that uses semiconductors as the primary means to control lamp..., and does not generally contain an igniter but instead starts lamps with high ballast open circuit...
NASA Astrophysics Data System (ADS)
Chee, Kuan W. A.; Hu, Yuning
2018-07-01
There has always been an inexorable interest in the solar industry in boosting the photovoltaic conversion efficiency. This paper presents a theoretical and numerical simulation study of the effects of key design parameters on the photoelectric performance of single junction (InGaP- or GaAs-based) and dual junction (InGaP/GaAs) inorganic solar cells. The influence of base layer thickness, base doping concentration, junction temperature, back surface field layer composition and thickness, and tunnel junction material, were correlated with open circuit voltage, short-circuit current, fill factor and power conversion efficiency performance. The InGaP/GaAs dual junction solar cell was optimized with the tunnel junction and back surface field designs, yielding a short-circuit current density of 20.71 mAcm-2 , open-circuit voltage of 2.44 V and fill factor of 88.6%, and guaranteeing an optimal power conversion efficiency of at least 32.4% under 1 sun AM0 illumination even without an anti-reflective coating.
1951-02-01
the pressure switch (16) is activated. This causes the-electrical circuit to open valve (11) and start the igniter (17). The nitrogen pressure...activates the pressure switch (11) at approximately 7 psi before it flows through the Injector (9) into the chamber. ATI-85«’ - -A 11...precluded. Accordingly, pressure switch (11) is inserted in the system in parallel (electrically) with the flow indicator (17), and the circuit may
Hybrid high direct current circuit interrupter
Rockot, Joseph H.; Mikesell, Harvey E.; Jha, Kamal N.
1998-01-01
A device and a method for interrupting very high direct currents (greater than 100,000 amperes) and simultaneously blocking high voltages (greater than 600 volts). The device utilizes a mechanical switch to carry very high currents continuously with low loss and a silicon controlled rectifier (SCR) to bypass the current around the mechanical switch while its contacts are separating. A commutation circuit, connected in parallel with the SCR, turns off the SCR by utilizing a resonant circuit to divert the SCR current after the switch opens.
Design of an improved RCD buffer circuit for full bridge circuit
NASA Astrophysics Data System (ADS)
Yang, Wenyan; Wei, Xueye; Du, Yongbo; Hu, Liang; Zhang, Liwei; Zhang, Ou
2017-05-01
In the full bridge inverter circuit, when the switch tube suddenly opened or closed, the inductor current changes rapidly. Due to the existence of parasitic inductance of the main circuit. Therefore, the surge voltage between drain and source of the switch tube can be generated, which will have an impact on the switch and the output voltage. In order to ab sorb the surge voltage. An improve RCD buffer circuit is proposed in the paper. The peak energy will be absorbed through the buffer capacitor of the circuit. The part energy feedback to the power supply, another part release through the resistor in the form of heat, and the circuit can absorb the voltage spikes. This paper analyzes the process of the improved RCD snubber circuit, According to the specific parameters of the main circuit, a reasonable formula for calculating the resistance capacitance is given. A simulation model will be modulated in Multisim, which compared the waveform of tube voltage and the output waveform of the circuit without snubber circuit with the improved RCD snubber circuit. By comparing and analyzing, it is proved that the improved buffer circuit can absorb surge voltage. Finally, experiments are demonstrated to validate that the correctness of the RC formula and the improved RCD snubber circuit.
A compositional framework for Markov processes
NASA Astrophysics Data System (ADS)
Baez, John C.; Fong, Brendan; Pollard, Blake S.
2016-03-01
We define the concept of an "open" Markov process, or more precisely, continuous-time Markov chain, which is one where probability can flow in or out of certain states called "inputs" and "outputs." One can build up a Markov process from smaller open pieces. This process is formalized by making open Markov processes into the morphisms of a dagger compact category. We show that the behavior of a detailed balanced open Markov process is determined by a principle of minimum dissipation, closely related to Prigogine's principle of minimum entropy production. Using this fact, we set up a functor mapping open detailed balanced Markov processes to open circuits made of linear resistors. We also describe how to "black box" an open Markov process, obtaining the linear relation between input and output data that holds in any steady state, including nonequilibrium steady states with a nonzero flow of probability through the system. We prove that black boxing gives a symmetric monoidal dagger functor sending open detailed balanced Markov processes to Lagrangian relations between symplectic vector spaces. This allows us to compute the steady state behavior of an open detailed balanced Markov process from the behaviors of smaller pieces from which it is built. We relate this black box functor to a previously constructed black box functor for circuits.
Reusable vibration resistant integrated circuit mounting socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, C.N.
1993-12-31
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and hold it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components.« less
Reusable vibration resistant integrated circuit mounting socket
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, C.N.
1995-08-29
This invention discloses a novel form of socket for integrated circuits to be mounted on printed circuit boards. The socket uses a novel contact which is fabricated out of a bimetallic strip with a shape which makes the end of the strip move laterally as temperature changes. The end of the strip forms a barb which digs into an integrated circuit lead at normal temperatures and holds it firmly in the contact, preventing loosening and open circuits from vibration. By cooling the contact containing the bimetallic strip the barb end can be made to release so that the integrated circuitmore » lead can be removed from the socket without damage either to the lead or to the socket components. 11 figs.« less
62. VIEW LOOKING NORTHWEST AT THE OIL FILLED CIRCUIT BREAKER ...
62. VIEW LOOKING NORTHWEST AT THE OIL FILLED CIRCUIT BREAKER FOR GENERATOR NUMBER 1. CIRCUIT BREAKERS ARE AUTOMATED SWITCHES WHICH DISCONNECT THE GENERATORS FROM THE LINE WHEN SHORT CIRCUITS OCCUR. WHEN CIRCUITS INVOLVING HIGH CURRENTS AND VOLTAGES ARE BROKEN, THE AIR SURROUNDING MECHANICAL PARTS OF THE SWITCH BECOMES IONIZED AND CONTINUES TO CONDUCT ELECTRIC POWER ACROSS ANY GAP IN THE SWITCH CONTACTS. TO PREVENT THIS AND INSURE A POSITIVE INTERRUPTION OF CURRENT, THE SWITCH CONTACTS ARE IMMERSED IN A CONTAINER OF OIL. THE OIL DOES NOT SUPPORT THE FORMATION OF AN ARC AND EFFECTIVELY CUTS OFF THE CURRENT WHEN THE SWITCH CONTACTS ARE OPENED. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT
Rajanna, Pramod Mulbagal; Gilshteyn, Evgenia; Yagafarov, Timur; Alekseeva, Alena; Anisimov, Anton; Sergeev, Oleg; Neumueller, Alex; Bereznev, Sergei; Maricheva, Jelena; Nasibulin, Albert
2018-01-09
We report a simple approach to fabricate hybrid solar cells (HSCs) based on a single-walled carbon nanotube (SWCNT) film and a thin film hydrogenated amorphous silicon (a-Si:H). Randomly oriented high quality SWCNTs with an enhanced conductivity by means of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate are used as a window layer and a front electrode. A series of HSCs are fabricated in ambient conditions with different SWCNT film thicknesses. The polymethylmethacrylate layer drop-casted on fabricated HSCs reduces the reflection fourfold and enhances the short-circuit Jsc, open-circuit Voc, and efficiency by nearly 10%. A state-of-the-art J-V performance is shown for SWCNT/a-Si HSC with an open-circuit voltage of 900 mV and efficiency of 3.4% under simulated one-sun AM 1.5G direct illumination. © 2018 IOP Publishing Ltd.
Rajanna, Pramod M; Gilshteyn, Evgenia P; Yagafarov, Timur; Aleekseeva, Alena K; Anisimov, Anton S; Neumüller, Alex; Sergeev, Oleg; Bereznev, Sergei; Maricheva, Jelena; Nasibulin, Albert G
2018-01-31
We report a simple approach to fabricate hybrid solar cells (HSCs) based on a single-walled carbon nanotube (SWCNT) film and thin film hydrogenated amorphous silicon (a-Si:H). Randomly oriented high-quality SWCNTs with conductivity enhanced by means of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate are used as a window layer and a front electrode. A series of HSCs are fabricated in ambient conditions with varying SWCNT film thicknesses. The polymethylmethacrylate layer drop-casted on fabricated HSCs reduces the reflection fourfold and enhances the short-circuit J sc , open-circuit V oc , and efficiency by nearly 10%. A state-of-the-art J-V performance is shown for SWCNT/a-Si HSC with an open-circuit voltage of 900 mV and an efficiency of 3.4% under simulated one-sun AM 1.5 G direct illumination.
Design optimization of GaAs betavoltaic batteries
NASA Astrophysics Data System (ADS)
Chen, Haiyanag; Jiang, Lan; Chen, Xuyuan
2011-06-01
GaAs junctions are designed and fabricated for betavoltaic batteries. The design is optimized according to the characteristics of GaAs interface states and the diffusion length in the depletion region of GaAs carriers. Under an illumination of 10 mCi cm-2 63Ni, the open circuit voltage of the optimized batteries is about ~0.3 V. It is found that the GaAs interface states induce depletion layers on P-type GaAs surfaces. The depletion layer along the P+PN+ junction edge isolates the perimeter surface from the bulk junction, which tends to significantly reduce the battery dark current and leads to a high open circuit voltage. The short circuit current density of the optimized junction is about 28 nA cm-2, which indicates a carrier diffusion length of less than 1 µm. The overall results show that multi-layer P+PN+ junctions are the preferred structures for GaAs betavoltaic battery design.
NASA Astrophysics Data System (ADS)
Chakrabartty, Joyprokash; Harnagea, Catalin; Celikin, Mert; Rosei, Federico; Nechache, Riad
2018-05-01
Inorganic ferroelectric perovskites are attracting attention for the realization of highly stable photovoltaic cells with large open-circuit voltages. However, the power conversion efficiencies of devices have been limited so far. Here, we report a power conversion efficiency of 4.20% under 1 sun illumination from Bi-Mn-O composite thin films with mixed BiMnO3 and BiMn2O5 crystal phases. We show that the photocurrent density and photovoltage mainly develop across grain boundaries and interfaces rather than within the grains. We also experimentally demonstrate that the open-circuit voltage and short-circuit photocurrent measured in the films are tunable by varying the electrical resistance of the device, which in turn is controlled by externally applying voltage pulses. The exploitation of multifunctional properties of composite oxides provides an alternative route towards achieving highly stable, high-efficiency photovoltaic solar energy conversion.
Rear surface effects in high efficiency silicon solar cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wenham, S.R.; Robinson, S.J.; Dai, X.
1994-12-31
Rear surface effects in PERL solar cells can lead not only to degradation in the short circuit current and open circuit voltage, but also fill factor. Three mechanisms capable of changing the effective rear surface recombination velocity with injection level are identified, two associated with oxidized p-type surfaces, and the third with two dimensional effects associated with a rear floating junction. Each of these will degrade the fill factor if the range of junction biases corresponding to the rear surface transition, coincides with the maximum power point. Despite the identified non idealities, PERL cells with rear floating junctions (PERF cells)more » have achieved record open circuit voltages for silicon solar cells, while simultaneously achieving fill factor improvements relative to standard PERL solar cells. Without optimization, a record efficiency of 22% has been demonstrated for a cell with a rear floating junction. The results of both theoretical and experimental studies are provided.« less
Radiation damage in high voltage silicon solar cells
NASA Technical Reports Server (NTRS)
Weinberg, I.; Brandhorst, H., Jr.; Swartz, C. K.; Weizer, V. G.
1980-01-01
Three high open-circuit voltage cell designs based on 0.1 ohm-cm p-type silicon were irradiated with 1 MeV electrons and their performance determined to fluences as high as 10 to the 15th power/sq cm. Of the three cell designs, radiation induced degradation was greatest in the high-low emitter (HLE cell). The diffused and ion implanted cells degraded approximately equally but less than the HLE cell. Degradation was greatest in an HLE cell exposed to X-rays before electron irradiation. The cell regions controlling both short-circuit current and open-circuit voltage degradation were defined in all three cell types. An increase in front surface recombination velocity accompanied time dependent degradation of an HLE cell after X-irradiation. It was speculated that this was indirectly due to a decrease in positive charge at the silicon-oxide interface. Modifications aimed at reducing radiation induced degradation are proposed for all three cell types.
An open-source laser electronics suite
NASA Astrophysics Data System (ADS)
Pisenti, Neal C.; Reschovsky, Benjamin J.; Barker, Daniel S.; Restelli, Alessandro; Campbell, Gretchen K.
2016-05-01
We present an integrated set of open-source electronics for controlling external-cavity diode lasers and other instruments in the laboratory. The complete package includes a low-noise circuit for driving high-voltage piezoelectric actuators, an ultra-stable current controller based on the design of, and a high-performance, multi-channel temperature controller capable of driving thermo-electric coolers or resistive heaters. Each circuit (with the exception of the temperature controller) is designed to fit in a Eurocard rack equipped with a low-noise linear power supply capable of driving up to 5 A at +/- 15 V. A custom backplane allows signals to be shared between modules, and a digital communication bus makes the entire rack addressable by external control software over TCP/IP. The modular architecture makes it easy for additional circuits to be designed and integrated with existing electronics, providing a low-cost, customizable alternative to commercial systems without sacrificing performance.
NASA Astrophysics Data System (ADS)
Rajanna, Pramod M.; Gilshteyn, Evgenia P.; Yagafarov, Timur; Aleekseeva, Alena K.; Anisimov, Anton S.; Neumüller, Alex; Sergeev, Oleg; Bereznev, Sergei; Maricheva, Jelena; Nasibulin, Albert G.
2018-03-01
We report a simple approach to fabricate hybrid solar cells (HSCs) based on a single-walled carbon nanotube (SWCNT) film and thin film hydrogenated amorphous silicon (a-Si:H). Randomly oriented high-quality SWCNTs with conductivity enhanced by means of poly(3,4-ethylenedioxythiophene) polystyrene sulfonate are used as a window layer and a front electrode. A series of HSCs are fabricated in ambient conditions with varying SWCNT film thicknesses. The polymethylmethacrylate layer drop-casted on fabricated HSCs reduces the reflection fourfold and enhances the short-circuit J sc , open-circuit V oc , and efficiency by nearly 10%. A state-of-the-art J-V performance is shown for SWCNT/a-Si HSC with an open-circuit voltage of 900 mV and an efficiency of 3.4% under simulated one-sun AM 1.5 G direct illumination.
Investigation of a temperature tolerant InGaP (GaInP) converter layer for a 63Ni betavoltaic cell
NASA Astrophysics Data System (ADS)
Butera, S.; Whitaker, M. D. C.; Krysa, A. B.; Barnett, A. M.
2017-08-01
A prototype InGaP p+-i-n+ mesa photodiode was studied for its potential as the energy conversion device in a 63Ni betavoltaic cell; its electrical performance was analysed across the temperature range -20 °C to 100 °C. The results show that the InGaP detector when illuminated with a laboratory 63Ni radioisotope beta particle source had a maximum output power of 0.92 pW at -20 °C, this value decreased at higher temperatures. A decrease in the open circuit voltage and in the cell internal conversion efficiency were also observed when the temperature was increased: at -20 °C, the open circuit voltage and the cell internal conversion efficiency had values of 0.69 V and 4%, respectively. A short circuit current of 4.5 pA was measured at -20 °C.
Low thermal resistance power module assembly
Hassani, Vahab; Vlahinos, Andreas; Bharathan, Desikan
2007-03-13
A power module assembly with low thermal resistance and enhanced heat dissipation to a cooling medium. The assembly includes a heat sink or spreader plate with passageways or openings for coolant that extend through the plate from a lower surface to an upper surface. A circuit substrate is provided and positioned on the spreader plate to cover the coolant passageways. The circuit substrate includes a bonding layer configured to extend about the periphery of each of the coolant passageways and is made up of a substantially nonporous material. The bonding layer may be solder material which bonds to the upper surface of the plate to provide a continuous seal around the upper edge of each opening in the plate. The assembly includes power modules mounted on the circuit substrate on a surface opposite the bonding layer. The power modules are positioned over or proximal to the coolant passageways.
Process Research on Polycrystalline Silicon Material (PROPSM)
NASA Technical Reports Server (NTRS)
Culik, J. S.
1983-01-01
The performance limiting mechanisms in large grain (greater than 1-2 mm in diameter) polycrystalline silicon was investigated by measuring the illuminated current voltage (I-V) characteristics of the minicell wafer set. The average short circuit current on different wafers is 3 to 14 percent lower than that of single crystal Czochralski silicon. The scatter was typically less than 3 percent. The average open circuit voltage is 20 to 60 mV less than that of single crystal silicon. The scatter in the open circuit voltage of most of the polycrystalline silicon wafers was 15 to 20 mV, although two wafers had significantly greater scatter than this value. The fill factor of both polycrystalline and single crystal silicon cells was typically in the range of 60 to 70 percent; however several polycrystalline silicon wafers have fill factor averages which are somewhat lower and have a significantly larger degree of scatter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chauhan, A. K., E-mail: akchau@barc.gov.in, E-mail: akc.barc@gmail.com; Gusain, Abhay; Jha, P.
2014-03-31
The solution of thin graphene-sheets obtained from a simple ultrasonic exfoliation process was found to chemically interact with [6,6]-phenyl C{sub 71} butyric acid methyl ester (PCBM) molecules. The thinner graphene-sheets have significantly altered the positions of highest occupied molecular orbital and lowest unoccupied molecular orbital of PCBM, which is beneficial for the enhancement of the open circuit voltage of the solar cells. Flexible bulk heterojunction solar cells fabricated using poly 3-hexylthiophene (P3HT):PCBM-graphene exhibited a power conversion efficiency of 2.51%, which is a ∼2-fold increase as compared to those fabricated using P3HT:PCBM. Inclusion of graphene-sheets not only improved the open-circuit voltagemore » but also enhanced the short-circuit current density owing to an improved electron transport.« less
Transient analysis of unbalanced short circuits of the ERDA-NASA 100 kW wind turbine alternator
NASA Technical Reports Server (NTRS)
Hwang, H. H.; Gilbert, L. J.
1976-01-01
Unbalanced short-circuit faults on the alternator of the ERDA-NASA Mod-O100-kW experimental wind turbine are studied. For each case, complete solutions for armature, field, and damper-circuit currents; short-circuit torque; and open-phase voltage are derived directly by a mathematical analysis. Formulated results are tabulated. For the Mod-O wind turbine alternator, numerical calculations are given, and results are presented by graphs. Comparisons for significant points among the more important cases are summarized. For these cases the transients are found to be potentially severe. The effect of the alternator neutral-to-ground impedance is evaluated.
Oxygenator in short-term LVAD circuit: a rescue in post-LVAD pulmonary complications.
Mohite, Prashant N; Patil, Nikhil P; Popov, Aron-Frederik; Bahrami, Toufan; Simon, Andre R
2016-10-01
Pulmonary complications after left ventricular assist device (LVAD) implantation, though infrequent, can be potentially catastrophic. A 62-year-old female with cardiogenic shock, supported on short-term LVAD, developed pulmonary oedema. An oxygenator was introduced into the LVAD circuit, which improved the gas exchange and, eventually, after weaning off the oxygenator, the patient received long-term LVAD. The introduction of an oxygenator into the short-term LAVD circuit is a lifesaving manoeuvre in such a situation. It offers freedom of introducing and removing the oxygenator into the LVAD circuit without opening the chest and competing for LVAD flow. © The Author(s) 2016.
de Araujo, Georgia Véras; Leite, Débora F B; Rizzo, José A; Sarinho, Emanuel S C
2016-08-01
The aim of this study was to identify a possible association between the assessment of clinical asthma control using the Asthma Control Test (ACT) and the Global Initiative for Asthma (GINA) classification and to perform comparisons with values of spirometry. Through this cross-sectional study, 103 pregnant women with asthma were assessed in the period from October 2010 to October 2013 in the asthma pregnancy clinic at the Clinical Hospital of the Federal University of Pernambuco. Questionnaires concerning the level of asthma control were administered using the Global Initiative for Asthma classification, the Asthma Control Test validated for asthmatic expectant mothers and spirometry; all three methods of assessing asthma control were performed during the same visit between the twenty-first and twenty-seventh weeks of pregnancy. There was a significant association between clinical asthma control assessment using the Asthma Control Test and the Global Initiative for Asthma classification (p<0.001). There were also significant associations between the results of the subjective instruments of asthma (the GINA classification and the ACT) and evidence of lung function by spirometry. This study shows that both the Global Initiative for Asthma classification and the Asthma Control Test can be used for asthmatic expectant mothers to assess the clinical control of asthma, especially at the end of the second trimester, which is assumed to be the period of worsening asthma exacerbations during pregnancy. We highlight the importance of the Asthma Control Test as a subjective instrument with easy application, easy interpretation and good reproducibility that does not require spirometry to assess the level of asthma control and can be used in the primary care of asthmatic expectant mothers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Pochekutova, Irina A; Korenbaum, Vladimir I
2013-04-01
Increased forced expiratory time was first recognized as a marker of obstruction half a century ago. However, the reported diagnostic capabilities of both auscultated forced expiratory time (FET(as)) and spirometric forced expiratory time are contradictory. Computer analysis of respiratory noises provides a precise estimation of acoustic forced expiratory noise time (FET(a)) being the object-measured analogue of FET(as). The aim of this study was to analyse FET(a) diagnostic capabilities in patients with asthma based on the hypothesis that FET(a) could reveal hidden bronchial obstruction. A group of asthma patients involved 149 males aged 16-25 years. In this group, 71 subjects had spirometry features of bronchial obstruction, meanwhile, the remaining 78 had normal spirometry. A control group involved 77 healthy subjects. Spirometry and forced expiratory tracheal noise recording were sequentially measured for each participant. FET(a) values were estimated by means of a developed computer procedure, including bandpass filtration (200-2000 Hz), waveform envelope calculation with accumulation period of 0.01 s, automated measurement of FET(a) at 0.5% level from the peak amplitude. Specificity, sensitivity and area under Receiver Operating Characteristic curve of FET(a) and its ratios to squared chest circumference, height, weight were indistinguishable with baseline spirometry index FEV1 /forced vital capacity. Meanwhile, acoustic features of obstruction were revealed in 41%-49% of subgroup of patients with asthma but normal spirometry. FET(a) of tracheal noise and its ratio to anthropometric parameters seem to be sensitive and specific tests of hidden bronchial obstruction in young male asthma patients. © 2012 The Authors. Respirology © 2012 Asian Pacific Society of Respirology.
Jo, Bum Seak; Myong, Jun Pyo; Rhee, Chin Kook; Yoon, Hyoung Kyu; Koo, Jung Wan; Kim, Hyoung Ryoul
2018-01-15
The present study aimed to update the prediction equations for spirometry and their lower limits of normal (LLN) by using the lambda, mu, sigma (LMS) method and to compare the outcomes with the values of previous spirometric reference equations. Spirometric data of 10,249 healthy non-smokers (8,776 females) were extracted from the fourth and fifth versions of the Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009; V, 2010-2012). Reference equations were derived using the LMS method which allows modeling skewness (lambda [L]), mean (mu [M]), and coefficient of variation (sigma [S]). The outcome equations were compared with previous reference values. Prediction equations were presented in the following form: predicted value = e{a + b × ln(height) + c × ln(age) + M - spline}. The new predicted values for spirometry and their LLN derived using the LMS method were shown to more accurately reflect transitions in pulmonary function in young adults than previous prediction equations derived using conventional regression analysis in 2013. There were partial discrepancies between the new reference values and the reference values from the Global Lung Function Initiative in 2012. The results should be interpreted with caution for young adults and elderly males, particularly in terms of the LLN for forced expiratory volume in one second/forced vital capacity in elderly males. Serial spirometry follow-up, together with correlations with other clinical findings, should be emphasized in evaluating the pulmonary function of individuals. Future studies are needed to improve the accuracy of reference data and to develop continuous reference values for spirometry across all ages. © 2018 The Korean Academy of Medical Sciences.
Peters, Ubong; Hernandez, Paul; Dechman, Gail; Ellsmere, James; Maksym, Geoffrey
2016-05-01
Obesity is associated with respiratory symptoms that are reported to improve with weight loss, but this is poorly reflected in spirometry, and few studies have measured respiratory mechanics with oscillometry. We investigated whether early changes in lung mechanics following weight loss are detectable with oscillometry. Furthermore, we investigated whether the changes in lung mechanics measured in the supine position following weight loss are associated with changes in sleep quality. Nineteen severely obese female subjects (mean body mass index, 47.2 ± 6.6 kg/m(2)) were evaluated using spirometry, oscillometry, plethysmography, and the Pittsburgh Sleep Quality Index before and 5 weeks after bariatric surgery. These tests were conducted in both the upright and the supine position, and pre- and postbronchodilation with 200 μg of salbutamol. Five weeks after surgery, weight loss of 11.5 ± 2.5 kg was not associated with changes in spirometry and plethysmography, with the exception of functional residual capacity. There were also no changes in upright respiratory system resistance (Rrs) or reactance following weight loss. Importantly, however, in the supine position, weight loss caused a substantial reduction in Rrs. In addition, sleep quality improved significantly and was highly correlated with the reduction in supine Rrs. Prior to weight loss, subjects did not respond to the bronchodilator when assessed in the upright position with either spirometry or oscillometry; however, with modest weight loss, bronchodilator responsiveness returned to the normal range. Improvements in lung mechanics occur very early after weight loss, mostly in the supine position, resulting in improved sleep quality. These improvements are detectable with oscillometry but not with spirometry.
Fisher, Andrew J; Yadegarfar, Mohammad E; Collerton, Joanna; Small, Therese; Kirkwood, Thomas B L; Davies, Karen; Jagger, Carol; Corris, Paul A
2016-01-01
Background People aged 85 years and older are the fastest growing age group worldwide. This study assessed respiratory health, prevalence of respiratory disease and use of spirometry in respiratory diagnosis in a population-based cohort of 85 year olds to better understand respiratory health and disease in this sector of society. Methods A single year birth-cohort of 85 year olds participated in a respiratory assessment at their home or residential institution including self-reporting of symptoms and measurement of spirometry. General practice medical records were reviewed for respiratory diagnoses and treatments. Findings In the 845 participants, a substantial burden of respiratory disease was seen with a prevalence of COPD in medical records of 16.6% (n=140). A large proportion of the cohort had environmental exposures through past or current smoking (64.2%, n=539) and occupational risk factors (33.6%, n=269). Spirometry meeting reliability criteria was performed in 87% (n=737) of participants. In the subgroup with a diagnosis of COPD (n=123), only 75.6% (n=93) satisfied Global Initiative in Obstructive Lung Disease (GOLD) criteria for airflow obstruction, and in a healthy subgroup without respiratory symptoms or diagnoses (n=151), 44.4% (n=67) reached GOLD criteria for airflow obstruction and 43.3% (n=29) National Institute of Health and Care Excellence criteria for at least moderate COPD. Interpretation Spirometry can be successfully performed in the very old, aged 85 years, and may help identify respiratory diseases such as COPD. However interpretation in this age group using current definitions of COPD based on spirometry indices may be difficult and lead to overdiagnosis in a healthy group with transient symptoms. PMID:26732736
Capacitive charge generation apparatus and method for testing circuits
Cole, E.I. Jr.; Peterson, K.A.; Barton, D.L.
1998-07-14
An electron beam apparatus and method for testing a circuit are disclosed. The electron beam apparatus comprises an electron beam incident on an outer surface of an insulating layer overlying one or more electrical conductors of the circuit for generating a time varying or alternating current electrical potential on the surface; and a measurement unit connected to the circuit for measuring an electrical signal capacitively coupled to the electrical conductors to identify and map a conduction state of each of the electrical conductors, with or without an electrical bias signal being applied to the circuit. The electron beam apparatus can further include a secondary electron detector for forming a secondary electron image for registration with a map of the conduction state of the electrical conductors. The apparatus and method are useful for failure analysis or qualification testing to determine the presence of any open-circuits or short-circuits, and to verify the continuity or integrity of electrical conductors buried below an insulating layer thickness of 1-100 {micro}m or more without damaging or breaking down the insulating layer. The types of electrical circuits that can be tested include integrated circuits, multi-chip modules, printed circuit boards and flexible printed circuits. 7 figs.
Capacitive charge generation apparatus and method for testing circuits
Cole, Jr., Edward I.; Peterson, Kenneth A.; Barton, Daniel L.
1998-01-01
An electron beam apparatus and method for testing a circuit. The electron beam apparatus comprises an electron beam incident on an outer surface of an insulating layer overlying one or more electrical conductors of the circuit for generating a time varying or alternating current electrical potential on the surface; and a measurement unit connected to the circuit for measuring an electrical signal capacitively coupled to the electrical conductors to identify and map a conduction state of each of the electrical conductors, with or without an electrical bias signal being applied to the circuit. The electron beam apparatus can further include a secondary electron detector for forming a secondary electron image for registration with a map of the conduction state of the electrical conductors. The apparatus and method are useful for failure analysis or qualification testing to determine the presence of any open-circuits or short-circuits, and to verify the continuity or integrity of electrical conductors buried below an insulating layer thickness of 1-100 .mu.m or more without damaging or breaking down the insulating layer. The types of electrical circuits that can be tested include integrated circuits, multi-chip modules, printed circuit boards and flexible printed circuits.
Integral Battery Power Limiting Circuit for Intrinsically Safe Applications
NASA Technical Reports Server (NTRS)
Burns, Bradley M.; Blalock, Norman N.
2010-01-01
A circuit topology has been designed to guarantee the output of intrinsically safe power for the operation of electrical devices in a hazardous environment. This design uses a MOSFET (metal oxide semiconductor field-effect transistor) as a switch to connect and disconnect power to a load. A test current is provided through a separate path to the load for monitoring by a comparator against a preset threshold level. The circuit is configured so that the test current will detect a fault in the load and open the switch before the main current can respond. The main current passes through the switch and then an inductor. When a fault occurs in the load, the current through the inductor cannot change immediately, but the voltage drops immediately to safe levels. The comparator detects this drop and opens the switch before the current in the inductor has a chance to respond. This circuit protects both the current and voltage from exceeding safe levels. Typically, this type of protection is accomplished by a fuse or a circuit breaker, but in order for a fuse or a circuit breaker to blow or trip, the current must exceed the safe levels momentarily, which may be just enough time to ignite anything in a hazardous environment. To prevent this from happening, a fuse is typically current-limited by the addition of the resistor to keep the current within safe levels while the fuse reacts. The use of a resistor is acceptable for non-battery applications where the wasted energy and voltage drop across the resistor can be tolerated. The use of the switch and inductor minimizes the wasted energy. For example, a circuit runs from a 3.6-V battery that must be current-limited to 200 mA. If the circuit normally draws 10 mA, then an 18-ohm resistor would drop 180 mV during normal operation, while a typical switch (0.02 ohm) and inductor (0.97 ohm) would only drop 9.9 mV. From a power standpoint, the current-limiting resistor protection circuit wastes about 18 times more power than the switch and the inductor configuration. In the fault condition, both the resistor and the inductor react immediately. The resistor reacts by allowing more current to flow and dropping the voltage. Initially, the inductor reacts by dropping the voltage, and then by not allowing the current to change. When the comparator detects the drop in voltage, it opens the switch, thus preventing any further current flow. The inductor alone is not sufficient protection, because after the voltage drop has settled, the inductor would then allow the current to change, in this example, the current would be 3.7 A. In the fault condition, the resistor is flowing 200 mA until the fuse blows (anywhere from 1 ms to 100 s), while the switch and inductor combination is flowing about 2 A test current while monitoring for the fault to be corrected. Finally, as an additional safety feature, the circuit can be configured to hold the switch opened until both the load and source are disconnected.
Office-based spirometry for early detection of obstructive lung disease.
Wallace, Laura D; Troy, Kenneth E
2006-09-01
To review the research-based evidence supporting smoking cessation as the only proven method to reduce chronic obstructive pulmonary disease (COPD) progression and to show that early detection of disease with office-based spirometry can lead to therapeutic intervention before physiologic symptoms arise. Extensive review of national and international scientific literature supplemented with drawings and algorithms. Early detection of COPD with spirometry, along with smoking cessation, and aggressive intervention can alter the insidious course of this highly preventable disease. It is imperative that nurse practitioners utilize this simple and inexpensive procedure to identify COPD in its earliest stages, so treatment can reduce individual and community disease burden, reduce morbidity and mortality, and help reduce healthcare costs. Determination of early airflow obstruction supports smoking cessation education, provides objective data for patient motivation, thereby doubling patient compliance and reducing further disease burden.
Murdoch, R.O.; Record, F.A.
1963-01-29
This invention relates to a fast-acting spring-loaded electrical switch which can break a 1500-volt circuit in one millisecond without arcing. In particular, a springloaded shorting bar is held in tension by a fusible wire. Passage of an electrical current pulse through the fusible wire breaks the fuse thereby releasing the shorting bar to open one and close another electrical circuit. (AEC)
Development of a Three-Tier Test to Assess Misconceptions about Simple Electric Circuits
ERIC Educational Resources Information Center
Pesman, Haki; Eryilmaz, Ali
2010-01-01
The authors aimed to propose a valid and reliable diagnostic instrument by developing a three-tier test on simple electric circuits. Based on findings from the interviews, open-ended questions, and the related literature, the test was developed and administered to 124 high school students. In addition to some qualitative techniques for…
ERIC Educational Resources Information Center
Gaigher, Estelle
2014-01-01
This article reports an exploratory multi-case study on how science teachers understand and envisage addressing learners' misconceptions about electric circuits. Four teachers from schools in and around a large South African city participated in the study. An open-ended questionnaire was designed in a novel way, questioning teachers about wrong…
Modeling Hidden Circuits: An Authentic Research Experience in One Lab Period
ERIC Educational Resources Information Center
Moore, J. Christopher; Rubbo, Louis J.
2016-01-01
Two wires exit a black box that has three exposed light bulbs connected together in an unknown configuration. The task for students is to determine the circuit configuration without opening the box. In the activity described in this paper, we navigate students through the process of making models, developing and conducting experiments that can…
2006-01-01
cough. Pain was assessed during incentive spirometry or coughing using a visual analogue scale (score from 1 to 10) with failure being a score...fracture multidisciplinary clinical pathway. SIMU Surgical Intermediate Care Unit; STICU Shock Trauma Intensive Care Unit; IS incentive spirometry ...monitored bed (Surgical Intermediate Care Unit or Shock Trauma Intensive Care Unit) where they received patient-controlled analgesia and incentive
Incentive spirometry in major surgeries: a systematic review.
Carvalho, Celso R F; Paisani, Denise M; Lunardi, Adriana C
2011-01-01
To conduct a systematic review to evaluate the evidence of the use of incentive spirometry (IS) for the prevention of postoperative pulmonary complications and for the recovery of pulmonary function in patients undergoing abdominal, cardiac and thoracic surgeries. Searches were performed in the following databases: Medline, Embase, Web of Science, PEDro and Scopus to select randomized controlled trials which the IS was used in pre- and/or post-operative in order to prevent postoperative pulmonary complications and/or recover lung function after abdominal, cardiac and thoracic surgery. Two reviewers independently assessed all studies. In addition, the studies quality was assessed using the PEDro scale. Thirty studies were included (14 abdominal, 13 cardiac and 3 thoracic surgery; n=3,370 patients). In the analysis of the methodological quality, studies achieved a PEDro average score of 5.6, 4.7 and 4.8 points in abdominal, cardiac and thoracic surgeries, respectively. Five studies (3 abdominal, 1 cardiac and 1 thoracic surgery) compared the effect of the IS with control group (no intervention) and no difference was detected in the evaluated outcomes. There was no evidence to support the use of incentive spirometry in the management of surgical patients. Despite this, the use of incentive spirometry remains widely used without standardization in clinical practice.
Impact of switching from Caucasian to Indian reference equations for spirometry interpretation.
Chhabra, S K; Madan, M
2018-03-01
In the absence of ethnically appropriate prediction equations, spirometry data in Indian subjects are often interpreted using equations for other ethnic populations. To evaluate the impact of switching from Caucasian (National Health and Nutrition Examination Survey III [NHANES III] and Global Lung Function Initiative [GLI]) equations to the recently published North Indian equations on spirometric interpretation, and to examine the suitability of GLI-Mixed equations for this population. Spirometry data on 12 323 North Indian patients were analysed using the North Indian equations as well as NHANES III, GLI-Caucasian and GLI-Mixed equations. Abnormalities and ventilatory patterns were categorised and agreement in interpretation was evaluated. The NHANES III and GLI-Caucasian equations and, to a lesser extent, the GLI-Mixed equations, predicted higher values and labelled more measurements as abnormal. In up to one third of the patients, these differed from Indian equations in the categorisation of ventilatory patterns, with more patients classified as having restrictive and mixed disease. The NHANES III and GLI-Caucasian equations substantially overdiagnose abnormalities and misclassify ventilatory patterns on spirometry in Indian patients. Such errors of interpretation, although less common with the GLI-Mixed equations, remain substantial and are clinically unacceptable. A switch to Indian equations will have a major impact on interpretation.
System for automatically switching transformer coupled lines
NASA Technical Reports Server (NTRS)
Dwinell, W. S. (Inventor)
1979-01-01
A system is presented for automatically controlling transformer coupled alternating current electric lines. The secondary winding of each transformer is provided with a center tap. A switching circuit is connected to the center taps of a pair of secondary windings and includes a switch controller. An impedance is connected between the center taps of the opposite pair of secondary windings. The switching circuit has continuity when the AC lines are continuous and discontinuity with any disconnect of the AC lines. Normally open switching means are provided in at least one AC line. The switch controller automatically opens the switching means when the AC lines become separated.
Trap seal for open circuit liquid cooled turbines
Grondahl, Clayton M.; Germain, Malcolm R.
1980-01-01
An improved trap seal for open circuit liquid cooled turbines is disclosed. The trap seal of the present invention includes an annular recess formed in the supply conduit of cooling channels formed in the airfoil of the turbine buckets. A cylindrical insert is located in the annular recesses and has a plurality of axial grooves formed along the outer periphery thereof and a central recess formed in one end thereof. The axial grooves and central recess formed in the cylindrical insert cooperate with the annular recess to define a plurality of S-shaped trap seals which permit the passage of liquid coolant but prohibit passage of gaseous coolant.
Primary and secondary room temperature molten salt electrochemical cells
NASA Astrophysics Data System (ADS)
Reynolds, G. F.; Dymek, C. J., Jr.
1985-07-01
Three novel primary cells which use room temperature molten salt electrolytes are examined and found to have high open circuit potentials in the 1.75-2.19 V range, by comparison with the Al/AlCl3-MEICl concentration cell; their cathodes were of FeCl3-MEICl, WCl6-MEICl, and Br2/reticulated vitreous carbon together with Pt. Also, secondary electrochemical cell candidates were examined which combined the reversible Al/AlCl3-MEICl electrode with reversible zinc and cadmium molten salt electrodes to yield open circuit potentials of about 0.7 and 1.0 V, respectively. Room temperature molten salts' half-cell reduction potentials are given.
Electrolyte Concentration Effect of a Photoelectrochemical Cell Consisting of TiO 2 Nanotube Anode
Ren, Kai; Gan, Yong X.; Nikolaidis, Efstratios; ...
2013-01-01
The photoelectrochemical responses of a TiO 2 nanotube anode in ethylene glycol (EG), glycerol, ammonia, ethanol, urea, and Na 2 S electrolytes with different concentrations were investigated. The TiO 2 nanotube anode was highly efficient in photoelectrocatalysis in these solutions under UV light illumination. The photocurrent density is obviously affected by the concentration change. Na 2 S generated the highest photocurrent density at 0, 1, and 2 V bias voltages, but its concentration does not significantly affect the photocurrent density. Urea shows high open circuit voltage at proper concentration and low photocurrent at different concentrations. Externally applied bias voltage is alsomore » an important factor that changes the photoelectrochemical reaction process. In view of the open circuit voltage, EG, ammonia, and ethanol fuel cells show the trend that the open circuit voltage (OCV) increases with the increase of the concentration of the solutions. Glycerol has the highest OCV compared with others, and it deceases with the increase in the concentration because of the high viscosity. The OCV of the urea and Na 2 S solutions did not show obvious concentration effect.« less
Biofuel cell based on direct bioelectrocatalysis.
Ramanavicius, Arunas; Kausaite, Asta; Ramanaviciene, Almira
2005-04-15
A biofuel cell, consisting of two 3mm diameter carbon rod electrodes and operating at ambient temperature in aqueous solution, pH 6, is described. Biofuel cell based on enzymes able to exchange directly electrons with carbon electrodes was constructed and characterized. Anode of the biofuel cell was based on immobilized Quino-hemoprotein alcohol dehydrogenase from Gluconobacter sp. 33 (QH-ADH), cathode on co-immobilized glucose oxidase from Aspergilus niger (GO(x)) and microperoxidase 8 from the horse heart (MP-8) acting in the consecutive mode. Two enzymes GO(x) and MP-8 applied in the design of biofuel cell cathode were acting in consecutive mode and by hydrogen peroxide oxidized MP-8 was directly accepting electrons from carbon rod electrode. If ethanol was applied as an energy source the maximal open circuit potential of the biofuel cell was -125 mV. If glucose was applied as energy source the open circuit potential of the cell was +145 mV. The maximal open circuit potential (270 mV) was achieved in the presence of extent concentration (over 2 mM) of both substrates (ethanol and glucose). Operational half-life period (tau(1/2)) of the biofuel cell was found to be 2.5 days.
NASA Astrophysics Data System (ADS)
Chantana, Jakapan; Kato, Takuya; Sugimoto, Hiroki; Minemoto, Takashi
2018-04-01
The temperature-illumination-dependent open-circuit voltage (VOC) method is utilized to separately and quantitatively estimate carrier recombination rates at the buffer/absorber interface, in the space-charge region (SCR), and in the quasi-neutral region (QNR) of Cu(In,Ga)(S,Se)2 (CIGSSe)-based thin-film solar cells with various device structures. The correlation between open-circuit voltage deficits (VOC,def) among the carrier recombination rates of the CIGSSe solar cells with a conversion efficiency (η) above 17% is examined. It is revealed that VOC,def is decreased to 0.373 V with the reduced carrier recombination rate at the buffer/absorber interface through the development of device structures. To further decrease VOC,def (for the improved η), the carrier recombination rates in SCR and QNR are essential to be reduced by the further improvement of CIGSSe quality. Consequently, understanding the quantitative carrier recombination rates across the device, estimated from the temperature-illumination-dependent VOC method, is practical to know which part of the solar cell needs to be developed for high η above 20%.
Development of a high efficiency thin silicon solar cell
NASA Technical Reports Server (NTRS)
Storti, G.; Culik, J.; Wrigley, C.
1980-01-01
Significant improvements in open-circuit voltage and conversion efficiency, even on relatively high bulk resistivity silicon, were achieved by using a screen-printed aluminum paste back surface field. A 4 sq cm 50 micron m thick cell was fabricated from textured 10 omega-cm silicon which had an open-circuit voltage of 595 mV and AMO conversion efficiency at 25 C of 14.3%. The best 4 sq cm 50 micron thick cell (2 omega-cm silicon) produced had an open-circuit voltage of 607 mV and an AMO conversion efficiency of 15%. Processing modifications are described which resulted in better front contact integrity and reduced breakage. These modifications were utilized in the thin cell pilot line to fabricate 4 sq cm cells with an average AMO conversion efficiency at 25 C of better than 12.5% and with lot yields as great as 51% of starts; a production rate of 10,000 cells per month was demonstrated. A pilot line was operated which produced large area (25 cm) ultra-thin cells with an average AMO conversion efficiency at 25 deg of better than 11.5% and a lot yield as high as 17%.
NASA Astrophysics Data System (ADS)
Itoh, Eiji; Takamizawa, Yuta; Miyairi, Keiichi
2008-01-01
We have prepared a photovoltaic device consisting of poly[2-methoxy,5-(2'-ethyl-hexyloxy)-p-phenylenevinylene] (MEHPPV) and an n-type crystalline TiO2 (anatase) thin film by high-temperature process and low-temperature process at a temperature lower than 150 °C by sol-gel techniques. The refluxed sol of titanium-tetraisopropoxide (TTI) with water and nitric acid formed anatase phase TiO2 without requiring the high-temperature process, and the wettability of sol is successfully improved by diluting sol with ethanol. The short circuit current JSC, fill factor, and the power conversion efficiency increase with the heat-treatment temperature of TiO2, which is attributed to the improvement of series resistance of the TiO2 film. On the other hand, the open circuit voltage remains almost constant (ca. 1.0 V) with the change in heat-treatment temperature between 60 and 120 °C, whereas it decreases to 0.76 V in the device prepared on the TiO2 film sintered at 500 °C, probably owing to the change in crystallinity. The origin of open circuit voltage in indium tin oxide (ITO)/TiO2/MEHPPV/Au is also discussed. The open circuit voltage corresponds well to the energy difference of the conduction band edge of TiO2 and the highest occupied molecular orbital (HOMO) of MEHPPV (ca. 1 eV) in the device consisting of the ITO/low-temperature TiO2/MEHPPV/Au system.
Transient-Switch-Signal Suppressor
NASA Technical Reports Server (NTRS)
Bozeman, Richard J., Jr.
1995-01-01
Circuit delays transmission of switch-opening or switch-closing signal until after preset suppression time. Used to prevent transmission of undesired momentary switch signal. Basic mode of operation simple. Beginning of switch signal initiates timing sequence. If switch signal persists after preset suppression time, circuit transmits switch signal to external circuitry. If switch signal no longer present after suppression time, switch signal deemed transient, and circuit does not pass signal on to external circuitry, as though no transient switch signal. Suppression time preset at value large enough to allow for damping of underlying pressure wave or other mechanical transient.
Fabricating and using a micromachined magnetostatic relay or switch
NASA Technical Reports Server (NTRS)
Tai, Yu-Chong (Inventor); Wright, John A. (Inventor)
2001-01-01
A micromachined magnetostatic relay or switch includes a springing beam on which a magnetic actuation plate is formed. The springing beam also includes an electrically conductive contact. In the presence of a magnetic field, the magnetic material causes the springing beam to bend, moving the electrically conductive contact either toward or away from another contact, and thus creating either an electrical short-circuit or an electrical open-circuit. The switch is fabricated from silicon substrates and is particularly useful in forming a MEMs commutation and control circuit for a miniaturized DC motor.
Hybrid high direct current circuit interrupter
Rockot, J.H.; Mikesell, H.E.; Jha, K.N.
1998-08-11
A device and a method are disclosed for interrupting very high direct currents (greater than 100,000 amperes) and simultaneously blocking high voltages (greater than 600 volts). The device utilizes a mechanical switch to carry very high currents continuously with low loss and a silicon controlled rectifier (SCR) to bypass the current around the mechanical switch while its contacts are separating. A commutation circuit, connected in parallel with the SCR, turns off the SCR by utilizing a resonant circuit to divert the SCR current after the switch opens. 7 figs.
[Research progress of mammalian synthetic biology in biomedical field].
Yang, Linfeng; Yin, Jianli; Wang, Meiyan; Ye, Haifeng
2017-03-25
Although still in its infant stage, synthetic biology has achieved remarkable development and progress during the past decade. Synthetic biology applies engineering principles to design and construct gene circuits uploaded into living cells or organisms to perform novel or improved functions, and it has been widely used in many fields. In this review, we describe the recent advances of mammalian synthetic biology for the treatment of diseases. We introduce common tools and design principles of synthetic gene circuits, and then we demonstrate open-loop gene circuits induced by different trigger molecules used in disease diagnosis and close-loop gene circuits used for biomedical applications. Finally, we discuss the perspectives and potential challenges of synthetic biology for clinical applications.
Cardiopulmonary Laboratory Career Ladder, AFSCs 90251 and 90271.
1983-12-01
RAND-HELD OR UPDRAFT NEBULIZERS 74 J283 INSTRUCT PATIENT IN USE OF INCENTIVE SPIROMETRY 74 E106 MAKE ENTRIES ON LOCAL FORMS FOR ARTERIAL BLOOD GAS...INSTRUCT PATIENT IN USE OF INCENTIVE SPIROMETRY 94 E109 MAKE ENTRIES ON LOCAL PULMONARY REQUEST FORMS 92 Ell MAK ENTRIES ON LOCAL TREADMILL REPORT FORMS...SCANNERS 31 44 . IMAGE INTENSIFIERS 7 14 INCENTIVE SPIROMETER DEVICES 71 62 MULTICHANNEL RECORDERS WITH TAPE RECORDERS 21 30 OSCILLOSCOPES 35 36
A computer system for analysis and transmission of spirometry waveforms using volume sampling.
Ostler, D V; Gardner, R M; Crapo, R O
1984-06-01
A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.
Incentive spirometry in postoperative abdominal/thoracic surgery patients.
Rupp, Michael; Miley, Helen; Russell-Babin, Kathleen
2013-01-01
Postoperative patients have higher incidences of respiratory complications. Patients undergoing abdominal or thoracic surgical procedures are at greater risk of having such complications. Incentive spirometry is an inhalation-based prophylactic technique that encourages patients to mimic a natural deep sigh to periodically increase lung volume. As this technique is the prophylactic method of choice for many hospitals, several studies have tested its efficacy. Five articles, including 4 systematic reviews and 1 clinical practice guideline, are analyzed and summarized. Each article was reviewed by a multidisciplinary team of health care providers and is discussed herein. A clinical recommendation for practice change is provided on the basis of the results. Incentive spirometry is only as effective as cough/deep-breathing regimens and other means of postoperative pulmonary prophylaxis. No single prophylactic technique clearly outperforms all others in preventing pulmonary complications. Future research is needed to determine the best method to prevent postoperative pulmonary complications.
Wang, Mei Lin; Storey, Eileen; Cassidy, Laura D; Doney, Brent; Conner, Patrick R; Collins, James J; Carson, Michael; Molenaar, Don
2017-12-01
The aim of this study was to investigate lung function among toluene diisocyanate (TDI) production workers. One hundred ninety-seven U.S workers performed spirometry from 2006 through 2012. Results were compared within the study cohort and with U.S. population measures. A mixed-effects model assessed factors affecting repeated forced expiratory volume in 1 second (FEV1) measurements. The cohort's mean FEV1 and forced vital capacity (FVC) percent reference values, although greater than 90%, were significantly lower and the prevalence of abnormal spirometry (predominantly restrictive pattern) was significantly higher than in the U.S. Differences in lung function among workers with higher cumulative TDI exposure were in the direction of an exposure effect, but not significant. We found little evidence of an adverse effect of TDI exposure on longitudinal spirometry in these workers. The association between TDI exposure and the increasing prevalence of a restrictive pattern needs further exploration.
Fabrication of Nanoscale Circuits on Inkjet-Printing Patterned Substrates.
Chen, Shuoran; Su, Meng; Zhang, Cong; Gao, Meng; Bao, Bin; Yang, Qiang; Su, Bin; Song, Yanlin
2015-07-08
Nanoscale circuits are fabricated by assembling different conducting materials (e.g., metal nanoparticles, metal nano-wires, graphene, carbon nanotubes, and conducting polymers) on inkjet-printing patterned substrates. This non-litho-graphy strategy opens a new avenue for integrating conducting building blocks into nanoscale devices in a cost-efficient manner. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Kong, Siu Cheung; Yeung, Yau Yuen; Wu, Xian Qiu
2009-01-01
In order to facilitate senior primary school students in Hong Kong to engage in learning by observation of the phenomena related to electrical circuits, a design of a specific courseware system, of which the interactive human-machine interface was created with the use of an open-source software called the LabVNC, for conducting online…
CdS/p-Si solar cells made by serigraphy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garcia, F.J.; Ortiz-Conde, A.; Sa-Neto, A.
1988-04-11
CdS/p-Si solar cells have been fabricated depositing the CdS layer by serigraphy. Open circuit voltages of 538 mV, short circuit current densities of 32 mA cm/sup -2/, fill factors of 0.52, and conversion efficiencies of 8.1% have been measured under 100 mW cm/sup -2/ (AM1) simulated solar illumination.
Radial direct bandgap p-i-n GaNP microwire solar cells with enhanced short circuit current
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sukrittanon, Supanee; Liu, Ren; Pan, Janet L.
2016-08-07
We report the demonstration of dilute nitride heterostructure core/shell microwire solar cells utilizing the combination of top-down reactive-ion etching to create the cores (GaP) and molecular beam epitaxy to create the shells (GaNP). Systematic studies of cell performance over a series of microwire lengths, array periods, and microwire sidewall morphologies examined by transmission electron microscopy were conducted to shed light on performance-limiting factors and to optimize the cell efficiency. We show by microscopy and correlated external quantum efficiency characterization that the open circuit voltage is degraded primarily due to the presence of defects at the GaP/GaNP interface and in themore » GaNP shells, and is not limited by surface recombination. Compared to thin film solar cells in the same growth run, the microwire solar cells exhibit greater short circuit current but poorer open circuit voltage due to greater light absorption and number of defects in the microwire structure, respectively. The comprehensive understanding presented in this work suggests that performance benefits of dilute nitride microwire solar cells can be achieved by further tuning of the epitaxial quality of the underlying materials.« less
Radial direct bandgap p-i-n GaNP microwire solar cells with enhanced short circuit current
NASA Astrophysics Data System (ADS)
Sukrittanon, Supanee; Liu, Ren; Breeden, Michael C.; Pan, Janet L.; Jungjohann, K. L.; Tu, Charles W.; Dayeh, Shadi A.
2016-08-01
We report the demonstration of dilute nitride heterostructure core/shell microwire solar cells utilizing the combination of top-down reactive-ion etching to create the cores (GaP) and molecular beam epitaxy to create the shells (GaNP). Systematic studies of cell performance over a series of microwire lengths, array periods, and microwire sidewall morphologies examined by transmission electron microscopy were conducted to shed light on performance-limiting factors and to optimize the cell efficiency. We show by microscopy and correlated external quantum efficiency characterization that the open circuit voltage is degraded primarily due to the presence of defects at the GaP/GaNP interface and in the GaNP shells, and is not limited by surface recombination. Compared to thin film solar cells in the same growth run, the microwire solar cells exhibit greater short circuit current but poorer open circuit voltage due to greater light absorption and number of defects in the microwire structure, respectively. The comprehensive understanding presented in this work suggests that performance benefits of dilute nitride microwire solar cells can be achieved by further tuning of the epitaxial quality of the underlying materials.
Radial direct bandgap p-i-n GaNP microwire solar cells with enhanced short circuit current
Sukrittanon, Supanee; Liu, Ren; Breeden, Michael C.; ...
2016-08-07
Here, we report the demonstration of dilute nitride heterostructure core/shell microwire solar cells utilizing the combination of top-down reactive-ion etching to create the cores (GaP) and molecular beam epitaxy to create the shells (GaNP). Systematic studies of cell performance over a series of microwire lengths, array periods, and microwire sidewall morphologies examined by transmission electron microscopy were conducted to shed light on performance-limiting factors and to optimize the cell efficiency. We also show by microscopy and correlated external quantum efficiency characterization that the open circuit voltage is degraded primarily due to the presence of defects at the GaP/GaNP interface andmore » in the GaNP shells, and is not limited by surface recombination. Compared to thin film solar cells in the same growth run, the microwire solar cells exhibit greater short circuit current but poorer open circuit voltage due to greater light absorption and number of defects in the microwire structure, respectively. Finally, we present performance benefits of dilute nitride microwire solar cells and show that it can be achieved by further tuning of the epitaxial quality of the underlying materials.« less
NASA Astrophysics Data System (ADS)
Zhu, Zhaozhao; Mankowski, Trent; Shikoh, Ali Sehpar; Touati, Farid; Benammar, Mohieddine A.; Mansuripur, Masud; Falco, Charles M.
2016-09-01
We report the synthesis of ultra-high aspect ratio copper nanowires (CuNW) and fabrication of CuNW-based transparent conductive electrodes (TCE) with high optical transmittance (>80%) and excellent sheet resistance (Rs <30 Ω/sq). These CuNW TCEs are subsequently hybridized with aluminum-doped zinc oxide (AZO) thin-film coatings, or platinum thin film coatings, or nickel thin-film coatings. Our hybrid transparent electrodes can replace indium tin oxide (ITO) films in dye-sensitized solar cells (DSSCs) as either anodes or cathodes. We highlight the challenges of integrating bare CuNWs into DSSCs, and demonstrate that hybridization renders the solar cell integrations feasible. The CuNW/AZO-based DSSCs have reasonably good open-circuit voltage (Voc = 720 mV) and short-circuit current-density (Jsc = 0.96 mA/cm2), which are comparable to what is obtained with an ITO-based DSSC fabricated with a similar process. Our CuNW-Ni based DSSCs exhibit a good open-circuit voltage (Voc = 782 mV) and a decent short-circuit current (Jsc = 3.96 mA/cm2), with roughly 1.5% optical-to-electrical conversion efficiency.
An, Qiaoshi; Zhang, Fujun; Li, Lingliang; Wang, Jian; Sun, Qianqian; Zhang, Jian; Tang, Weihua; Deng, Zhenbo
2015-02-18
We present a smart strategy to simultaneously increase the short circuit current (Jsc), the open circuit voltage (Voc), and the fill factor (FF) of polymer solar cells (PSCs). A two-dimensional conjugated small molecule photovoltaic material (SMPV1), as the second electron donor, was doped into the blend system of poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl-C71-butyric acid methyl (PC71BM) to form ternary PSCs. The ternary PSCs with 5 wt % SMPV1 doping ratio in donors achieve 4.06% champion power conversion efficiency (PCE), corresponding to about 21.2% enhancement compared with the 3.35% PCE of P3HT:PC71BM-based PSCs. The underlying mechanism on performance improvement of ternary PSCs can be summarized as (i) harvesting more photons in the longer wavelength region to increase Jsc; (ii) obtaining the lower mixed highest occupied molecular orbital (HOMO) energy level by incorporating SMPV1 to increase Voc; (iii) forming the better charge carrier transport channels through the cascade energy level structure and optimizing phase separation of donor/acceptor materials to increase Jsc and FF.
Low-level laser therapy improves the VO2 kinetics in competitive cyclists.
Lanferdini, Fábio J; Krüger, Renata L; Baroni, Bruno M; Lazzari, Caetano; Figueiredo, Pedro; Reischak-Oliveira, Alvaro; Vaz, Marco A
2018-04-01
Some evidence supports that low-level laser therapy (LLLT) reduces neuromuscular fatigue, so incrementing sports performance. A previous randomized controlled trial of our group showed increased exercise tolerance in male competitive cyclists treated with three different LLLT doses (3, 6, and 9 J/diode; or 135, 270, and 405 J/thigh) before time-to-exhaustion cycling tests. Now, the present study was designed to evaluate the effects of these LLLT doses on the VO 2 kinetics of athletes during cycling tests. Twenty male competitive cyclists (29 years) participated in a crossover, randomized, double-blind, and placebo-controlled trial. On the first day, the participants performed an incremental cycling test to exhaustion to determine maximal oxygen uptake (VO 2MAX ) and maximal power output (PO MAX ), as well as a familiarization with the time-to-exhaustion test. In the following days (2 to 5), all participants performed time-to-exhaustion tests at PO MAX . Before the exhaustion test, different doses of LLLT (3, 6, and 9 J/diode; or 135, 270, and 405 J/thigh, respectively) or placebo were applied bilaterally to the quadriceps muscle. All exhaustion tests were monitored online by an open-circuit spirometry system in order to analyze the VO 2 amplitude, VO 2 delay time, time constant (tau), and O 2 deficit. Tau and O 2 deficit were decreased with LLLT applications compared to the placebo condition (p < 0.05). No differences (p > 0.05) were found between the experimental conditions for VO 2 amplitude and VO 2 delay time. In conclusion, LLLT decreases tau and O 2 deficit during time-to-exhaustion tests in competitive cyclists, and these changes in VO 2 kinetics response can be one of the possible mechanisms to explain the ergogenic effect induced by LLLT.
The NATO III 5 MHz Distribution System
NASA Technical Reports Server (NTRS)
Vulcan, A.; Bloch, M.
1981-01-01
A high performance 5 MHz distribution system is described which has extremely low phase noise and jitter characteristics and provides multiple buffered outputs. The system is completely redundant with automatic switchover and is self-testing. Since the 5 MHz reference signals distributed by the NATO III distribution system are used for up-conversion and multiplicative functions, a high degree of phase stability and isolation between outputs is necessary. Unique circuit design and packaging concepts insure that the isolation between outputs is sufficient to quarantee a phase perturbation of less than 0.0016 deg when other outputs are open circuited, short circuited or terminated in 50 ohms. Circuit design techniques include high isolation cascode amplifiers. Negative feedback stabilizes system gain and minimizes circuit phase noise contributions. Balanced lines, in lieu of single ended coaxial transmission media, minimize pickup.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kellie, S.E.; Attfield, M.D.; Hankinson, J.L.
1987-03-01
To clarify the association between spirometry variability and respiratory morbidity and mortality, the authors analyzed data for miners examined in the first round of the National Coal Study, 1969-1971, and they compared groups of miners who failed with those who met each of two spirometry variability criteria: a 5% criterion recommended by the American Thoracic Society, and a 200 ml criterion used in prior research studies. Compared with miners who met the 5% criterion (the best two forced vital capacities must be within 5% or 100 ml of one another), the group that failed had a lower mean for forcedmore » expiratory volume in one second (FEV1), and odds ratios for cough, phlegm, wheeze, shortness of breath, and death of 1.75, 1.67, 1.76, 2.71, and 1.30, respectively. The findings for the 200 ml criterion (the best two FEV1s must be within 200 ml of one another) were somewhat different. The group that failed versus the group that met this criterion had a higher mean for FEV1, and odds ratios for cough, phlegm, wheeze, shortness of breath, and death of 1.13, 1.07, 1.15, 1.43, and 0.94, respectively. Although the findings differ for the two criteria, the findings demonstrate that increased spirometry variability is associated with poorer health.« less
Low-high junction theory applied to solar cells
NASA Technical Reports Server (NTRS)
Godlewski, M. P.; Baraona, C. R.; Brandhorst, H. W., Jr.
1974-01-01
Recent use of alloying techniques for rear contact formation has yielded a new kind of silicon solar cell, the back surface field (BSF) cell, with abnormally high open-circuit voltage and improved radiation resistance. Several analytical models for open-circuit voltage based on the reverse saturation current are formulated to explain these observations. The zero surface recombination velocity (SRV) case of the conventional cell model, the drift field model, and the low-high junction (LHJ) model can predict the experimental trends. The LHJ model applies the theory of the low-high junction and is considered to reflect a more realistic view of cell fabrication. This model can predict the experimental trends observed for BSF cells.
Super NiCd Open-Circuit Storage and Low Earth Orbit (LEO) Life Test Evaluation
NASA Technical Reports Server (NTRS)
Baer, Jean Marie; Hwang, Warren C.; Ang, Valerie J.; Hayden, Jeff; Rao, Gopalakrishna; Day, John H. (Technical Monitor)
2002-01-01
This presentation discusses Air Force tests performed on super NiCd cells to measure their performance under conditions simulating Low Earth Orbit (LEO) conditions. Super NiCd cells offer potential advantages over existing NiCd cell designs including advanced cell design with improved separator material and electrode making processes, but handling and storage requires active charging. These tests conclude that the super NiCd cells support generic Air Force qualifications for conventional LEO missions (up to five years duration) and that handling and storage may not actually require active charging as previously assumed. Topics covered include: Test Plan, Initial Characterization Tests, Open-Circuit Storage Tests, and post storage capacities.
NASA Technical Reports Server (NTRS)
Reid, M. A.; Gahn, R. F.
1977-01-01
The effect of acid concentration on the performance of the iron-titanium redox flow cell was studied. When the acidity was increased, open-circuit voltages decreased on the titanium side but load voltages increased due to decreased polarization. The best load voltage occurs when there is high acidity on the titanium side coupled with low acidity on the iron side, but such cells show voltage losses with repeated cycling because of the diffusion of acid through the membrane. No membrane tested has been found capable of maintaining the differences in acidity. Chelating agents show some promise in reducing polarization at the Ti electrode and thus improving energy efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Archana, P. S.; Gupta, Arunava; Yusoff, Mashitah M.
Zirconium (Zr) is doped up to 5 at. % in anatase TiO{sub 2} nanowires by electrospinning and used as working electrode in dye-sensitized solar cells. Variations observed in the photovoltaic parameters were correlated by electrochemical impedance spectroscopy, open circuit voltage decay, and X-ray diffraction measurements. Results show that homovalent substitution of Zr in TiO{sub 2} increased the chemical capacitance and electron diffusion coefficient which in turn decreased charge transport resistance and charge transit time. However, lattice strain due to size mismatch between the Zr{sup 4+} and Ti{sup 4+} ions decreased open circuit voltage and fill factor thereby setting a trade-off betweenmore » doping concentration and photovoltaic properties.« less
High work function transparent middle electrode for organic tandem solar cells
NASA Astrophysics Data System (ADS)
Moet, D. J. D.; de Bruyn, P.; Blom, P. W. M.
2010-04-01
The use of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) (PEDOT:PSS) in combination with ZnO as middle electrode in solution-processed organic tandem solar cells requires a pH modification of the PEDOT:PSS dispersion. We demonstrate that this neutralization leads to a reduced work function of PEDOT:PSS, which does not affect the performance of polythiophene:fullerene solar cells, but results in a lower open-circuit voltage of devices based on a polyfluorene derivative with a higher ionization potential. The introduction of a thin layer of a perfluorinated ionomer recovers the anode work function and gives an open-circuit voltage of 1.92 V for a double junction polyfluorene-based solar cell.
Influence of a MoOx interlayer on the open-circuit voltage in organic photovoltaic cells
NASA Astrophysics Data System (ADS)
Zou, Yunlong; Holmes, Russell J.
2013-07-01
Metal-oxides have been used as interlayers at the anode-organic interface in organic photovoltaic cells (OPVs) to increase the open-circuit voltage (VOC). We examine the role of MoOx in determining the maximum VOC in a planar heterojunction OPV and find that the interlayer strongly affects the temperature dependence of VOC. Boron subphthalocyanine chloride (SubPc)-C60 OPVs that contain no interlayer show a maximum VOC of 1.2 V at low temperature, while those with MoOx show no saturation, reaching VOC > 1.4 V. We propose that the MoOx-SubPc interface forms a Schottky junction that provides an additional contribution to VOC at low temperature.
Process Research of Polycrystalline Silicon Material (PROPSM)
NASA Technical Reports Server (NTRS)
Culik, J. S.
1984-01-01
An investigation was begun into the usefulness of molecular hydrogen annealing on polycrystalline solar cells. No improvement was realized even after twenty hours of hydrogenation. Thus, samples were chosen on the basis of: (1) low open circuit voltage; (2) low shunt conductance; and (3) high light generated current. These cells were hydrogenated in molecular hydrogen at 300 C. The differences between the before and after hydrogenation values are so slight as to be negligible. These cells have light generated current densities that indicate long minority carrier diffusion lengths. The open circuit voltage appears to be degraded, and quasi-neutral recombination current enhanced. Therefore, molecular hydrogen is not usful for passivating electrically active defects.
Micro-fabricated integrated coil and magnetic circuit and method of manufacturing thereof
Mihailovich, Robert E.; Papavasiliou, Alex P.; Mehrotra, Vivek; Stupar, Philip A.; Borwick, III, Robert L.; Ganguli, Rahul; DeNatale, Jeffrey F.
2017-03-28
A micro-fabricated electromagnetic device is provided for on-circuit integration. The electromagnetic device includes a core. The core has a plurality of electrically insulating layers positioned alternatingly between a plurality of magnetic layers to collectively form a continuous laminate having alternating magnetic and electrically insulating layers. The electromagnetic device includes a coil embedded in openings of the semiconductor substrate. An insulating material is positioned in the cavity and between the coil and an inner surface of the core. A method of manufacturing the electromagnetic device includes providing a semiconductor substrate having openings formed therein. Windings of a coil are electroplated and embedded in the openings. The insulating material is coated on or around an exposed surface of the coil. Alternating magnetic layers and electrically insulating layers may be micro-fabricated and electroplated as a single and substantially continuous segment on or around the insulating material.
Series-counterpulse repetitive-pulse inductive storage circuit
Honig, E.M.
1984-06-05
A high-power series-counterpulse repetitive-pulse inductive energy storage and transfer circuit includes an opening switch, a main energy storage coil, and a counterpulse capacitor. The local pulse is initiated simultaneously with the initiation of the counterpulse used to turn the opening switch off. There is no delay from command to output pulse. During the load pulse, the counterpulse capacitor is automatically charged with sufficient energy to accomplish the load counterpulse which terminates the load pulse and turns the load switch off. When the main opening switch is reclosed to terminate the load pulse, the counterpulse capacitor discharges through the load, causing a rapid, sharp cutoff of the load pulse as well as recovering any energy remaining in the load inductance. The counterpulse capacitor is recharged to its original condition by the main energy storage coil after the load pulse is over, not before it begins.
High efficiency organic photovoltaic cells based on a vapor deposited squaraine donor
NASA Astrophysics Data System (ADS)
Wang, Siyi; Mayo, Elizabeth I.; Perez, M. Dolores; Griffe, Laurent; Wei, Guodan; Djurovich, Peter I.; Forrest, Stephen R.; Thompson, Mark E.
2009-06-01
2,4-bis[4-(N ,N-diisobutylamino)-2,6-dihydroxyphenyl] squaraine (SQ) is used as a donor material in vapor deposited organic heterojunction photovoltaic cells. Devices with the structure indium tin oxide/SQ (x)/C60 (400Å)/bathocuproine (100Å)/Al (1000Å), where x =65, 110, 150, and 200Å were compared. Devices with x =65Å exhibited a power conversion efficiency of 3.1% under 1sun, AM1.5G simulated solar irradiation, giving an open circuit voltage of 0.76±0.01V, a short circuit current of 7.01±0.05mA/cm2, and a fill factor of 0.56±0.05. Thicker SQ films lead to lower short circuit currents and fill factors, giving conversion efficiencies in the range of 2.6% to 3.2%. The demonstration of sublimable SQ as a donor material opens up a family of compounds for use in small molecule based heterojunction photovoltaics.
NASA Astrophysics Data System (ADS)
Wang, R.; Demerdash, N. A.
1992-06-01
The combined magnetic vector potential - magnetic scalar potential method of computation of 3D magnetic fields by finite elements, introduced in a companion paper, is used for global 3D field analysis and machine performance computations under open-circuit and short-circuit conditions for an example 14.3 kVA modified Lundell alternator, whose magnetic field is of intrinsic 3D nature. The computed voltages and currents under these machine test conditions were verified and found to be in very good agreement with corresponding test data. Results of use of this modelling and computation method in the study of a design alteration example, in which the stator stack length of the example alternator is stretched in order to increase voltage and volt-ampere rating, are given here. These results demonstrate the inadequacy of conventional 2D-based design concepts and the imperative of use of this type of 3D magnetic field modelling in the design and investigation of such machines.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schnabel, Manuel; Klein, Talysa; Lee, Benjamin G
The rear side metallization of Si solar cells comes with a number of inherent losses and trade-offs: a larger metallized area fraction improves fill factor at the expense of open-circuit voltage, depositing directly on textured Si leads to low contact resistivity at the expense of short-circuit current, and some metallization processes create defects in Si. To mitigate many of these losses we have developed a novel approach for rear side metallization of Si solar cells, utilizing a transparent conducting adhesive (TCA) to metallize Si without exposing the wafer to the metal deposition process. The TCA consists of an insulating adhesivemore » loaded with conductive microspheres. This approach leads to virtually no loss in implied open-circuit voltage upon metallization. Electrical measurements showed that contact resistivities of 3-9 ..omega.. cm2 were achieved, and an analysis of the transit resistance per microsphere showed that less than 1 ..omega.. cm2 should be achievable with higher microsphere loading of the TCA.« less
Xu, Hao; Tong, Na; Huang, Shaobin; Zhou, Shaofeng; Li, Shuang; Li, Jianjun; Zhang, Yongqing
2018-05-03
This study aimed to investigate the degradation efficiency of 2,4,6-trichlorophenol through a batch of potentiostatic experiments (0.2 V vs. Ag/AgCl). Efficiencies in the presence and absence of acetate and glucose were compared through open-circuit reference experiments. Significant differences in degradation efficiency were observed in six reactors. The highest and lowest degradation efficiencies were observed in the closed-circuit reactor fed with glucose and in the open-circuit reactor, respectively. This finding was due to the enhanced bacterial metabolism caused by the application of micro-electrical field and degradable organics as co-substrates. The different treatment efficiencies were also caused by the distinct bacterial communities. The composition of bacterial community was affected by adding different organics as co-substrates. At the phylum level, the most dominant bacteria in the reactor with the added acetate and glucose were Proteobacteria and Firmicutes, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.
Process Research On Polycrystalline Silicon Material (PROPSM). [flat plate solar array project
NASA Technical Reports Server (NTRS)
Culik, J. S.
1983-01-01
The performance-limiting mechanisms in large-grain (greater than 1 to 2 mm in diameter) polycrystalline silicon solar cells were investigated by fabricating a matrix of 4 sq cm solar cells of various thickness from 10 cm x 10 cm polycrystalline silicon wafers of several bulk resistivities. Analysis of the illuminated I-V characteristics of these cells suggests that bulk recombination is the dominant factor limiting the short-circuit current. The average open-circuit voltage of the polycrystalline solar cells is 30 to 70 mV lower than that of co-processed single-crystal cells; the fill-factor is comparable. Both open-circuit voltage and fill-factor of the polycrystalline cells have substantial scatter that is not related to either thickness or resistivity. This implies that these characteristics are sensitive to an additional mechanism that is probably spatial in nature. A damage-gettering heat-treatment improved the minority-carrier diffusion length in low lifetime polycrystalline silicon, however, extended high temperature heat-treatment degraded the lifetime.
NASA Technical Reports Server (NTRS)
Wang, R.; Demerdash, N. A.
1992-01-01
The combined magnetic vector potential - magnetic scalar potential method of computation of 3D magnetic fields by finite elements, introduced in a companion paper, is used for global 3D field analysis and machine performance computations under open-circuit and short-circuit conditions for an example 14.3 kVA modified Lundell alternator, whose magnetic field is of intrinsic 3D nature. The computed voltages and currents under these machine test conditions were verified and found to be in very good agreement with corresponding test data. Results of use of this modelling and computation method in the study of a design alteration example, in which the stator stack length of the example alternator is stretched in order to increase voltage and volt-ampere rating, are given here. These results demonstrate the inadequacy of conventional 2D-based design concepts and the imperative of use of this type of 3D magnetic field modelling in the design and investigation of such machines.
Qin, Yunpeng; Chen, Yu; Cui, Yong; Zhang, Shaoqing; Yao, Huifeng; Huang, Jiang; Li, Wanning; Zheng, Zhong; Hou, Jianhui
2017-06-01
Tandem organic solar cells (TOSCs), which integrate multiple organic photovoltaic layers with complementary absorption in series, have been proved to be a strong contender in organic photovoltaic depending on their advantages in harvesting a greater part of the solar spectrum and more efficient photon utilization than traditional single-junction organic solar cells. However, simultaneously improving open circuit voltage (V oc ) and short current density (J sc ) is a still particularly tricky issue for highly efficient TOSCs. In this work, by employing the low-bandgap nonfullerene acceptor, IEICO, into the rear cell to extend absorption, and meanwhile introducing PBDD4T-2F into the front cell for improving V oc , an impressive efficiency of 12.8% has been achieved in well-designed TOSC. This result is also one of the highest efficiencies reported in state-of-the-art organic solar cells. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Low thermal resistance power module assembly
Hassani, Vahab; Vlahinos, Andreas; Bharathan, Desikan
2010-12-28
A power module assembly (400) with low thermal resistance and enhanced heat dissipation to a cooling medium. The assembly includes a heat sink or spreader plate (410) with passageways or openings (414) for coolant that extend through the plate from a lower surface (411) to an upper surface (412). A circuit substrate (420) is provided and positioned on the spreader plate (410) to cover the coolant passageways. The circuit substrate (420) includes a bonding layer (422) configured to extend about the periphery of each of the coolant passageways and is made up of a substantially nonporous material. The bonding layer (422) may be solder material which bonds to the upper surface (412) of the plate to provide a continuous seal around the upper edge of each opening (414) in the plate. The assembly includes power modules (430) mounted on the circuit substrate (420) on a surface opposite the bonding layer (422). The power modules (430) are positioned over or proximal to the coolant passageways.
ERIC Educational Resources Information Center
Baser, Mustafa
2006-01-01
This paper reports upon an active learning approach that promotes conceptual change when studying direct current electricity circuits, using free open source software, "Qucs". The study involved a total of 102 prospective mathematics teacher students. Prior to instruction, students' understanding of direct current electricity was…
Air emissions and residual ash measurements were made from open, uncontrolled combustion of electronic waste (e-waste) during simulations of practices associated with rudimentary e-waste recycling operations. Circuit boards and insulated wires were separately burned to simulate p...
Switching of High-Voltage Cable Lines with Shunt Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheskin, E. B., E-mail: evgeniy.sheskin@gmail.com; Evdokunin, G. A.
2016-05-15
The problem of disconnecting high-voltage cable lines with shunt reactors by SF{sub 6} circuit breakers is discussed. In these schemes it is possible to have a significant aperiodic component of the circuit breaker current that can prevent opening of the breaker. The authors propose methods for application to cable transmission lines which they believe will be optimal for ensuring normal disconnects.
Pre-resistance-welding resistance check
Destefan, Dennis E.; Stompro, David A.
1991-01-01
A preweld resistance check for resistance welding machines uses an open circuited measurement to determine the welding machine resistance, a closed circuit measurement to determine the parallel resistance of a workpiece set and the machine, and a calculation to determine the resistance of the workpiece set. Any variation in workpiece set or machine resistance is an indication that the weld may be different from a control weld.
1973-12-18
abosrbent canister under all of the conditions in which the helmet will be expected to operate. These tests are very similar to those of Section III. B. 4... abosrbent canister will be operating but on air). Since the CO2 absorbent canister is not operating, it need not be instrumented. b. Recommended Tests -W 1
ERIC Educational Resources Information Center
Ferri, Bonni H.; Ferri, Aldo A.; Majerich, David M.; Madden, Amanda G.
2016-01-01
This paper examines the effects of hands-on learning in an undergraduate circuits class that is taught to non-majors; i.e., students outside of electrical and computing engineering. The course, ECE3710, is taught in a blended format facilitated by the video lectures prepared for two Massive Open Online Courses developed for the Coursera Platform.…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alderfer, R.R.; Futa, P.W.
This patent describes a fuel system for an engine having a filter through which fuel from a pump passes to a regulator in response to an operator input. The regulator controls the flow of fuel presented to a combustion chamber in the engine, the regulator having a feedback apparatus to provide an operator with a signal indicative of the fuel supplied to the combustion chamber. It comprises: bypass means having a housing with a chamber therein, the chamber having an entrance port connected to the pump and an exit port connected to the regulator; piston means located in the chambermore » for separating the entrance port from the exit port, the piston having a face with a projection extending therefrom; stop means located in the chamber; resilient means located is the chamber for urging the piston means toward the stop means to prevent the flow of fuel from the pump through the housing to the regulator; and indicator means having a body retained in the housing with a first end which extends through the housing into the from a full-open position at which the closed circuit is fully opened to a full-closed position at which the closed circuit is fully blocked; ratio detecting means which detects the speed reduction ratio to find if the speed reduction ratio becomes substantially 1; and valve position detecting means which detects position of the direct clutch valve to find if the direct clutch valve is moved to a slight-open position at which the closed circuit is slightly opened.« less
Agostini, Paula; Naidu, Babu; Cieslik, Hayley; Steyn, Richard; Rajesh, Pala Babu; Bishay, Ehab; Kalkat, Maninder Singh; Singh, Sally
2013-06-01
Following thoracotomy, patients frequently receive routine respiratory physiotherapy which may include incentive spirometry, a breathing technique characterised by deep breathing performed through a device offering visual feedback. This type of physiotherapy is recommended and considered important in the care of thoracic surgery patients, but high quality evidence for specific interventions such as incentive spirometry remains lacking. 180 patients undergoing thoracotomy and lung resection participated in a prospective single-blind randomised controlled trial. All patients received postoperative breathing exercises, airway clearance and early mobilisation; the control group performed thoracic expansion exercises and the intervention group performed incentive spirometry. No difference was observed between the intervention and control groups in the mean drop in forced expiratory volume in 1 s on postoperative day 4 (40% vs 41%, 95% CI -5.3% to 4.2%, p=0.817), the frequency of postoperative pulmonary complications (PPC) (12.5% vs 15%, 95% CI -7.9% to 12.9%, p=0.803) or in any other secondary outcome measure. A high-risk subgroup (defined by ≥2 independent risk factors; age ≥75 years, American Society of Anaesthesiologists score ≥3, chronic obstructive pulmonary disease (COPD), smoking status, body mass index ≥30) also demonstrated no difference in outcomes, although a larger difference in the frequency of PPC was observed (14% vs 23%) with 95% CIs indicating possible benefit of intervention (-7.4% to 2.6%). Incentive spirometry did not improve overall recovery of lung function, frequency of PPC or length of stay. For patients at higher risk for the development of PPC, in particular those with COPD or current/recent ex-smokers, there were larger observed actual differences in the frequency of PPC in favour of the intervention, indicating that investigations regarding the physiotherapy management of these patients need to be developed further.
López Varela, Maria Victorina; Montes de Oca, Maria; Rey, Alejandra; Casas, Alejandro; Stirbulov, Roberto; Di Boscio, Valentina
2016-10-01
Opportunistic chronic obstructive pulmonary disease (COPD) case finding approaches for high-risk individuals with or without symptoms is a feasible option for disease identification. PUMA is an opportunistic case finding study conducted in primary care setting of Argentina, Colombia, Venezuela and Uruguay. The objectives were to measure COPD prevalence in an at-risk population visiting primary care for any reason, to assess the yield of this opportunistic approach and the accuracy of a score developed to detect COPD. Subjects attending routine primary care visits, ≥40 years of age, current or former smokers or exposed to biomass smoke, completed a questionnaire and performed spirometry. COPD was defined as post-bronchodilator (post-BD) forced expiratory volume in 1 s (FEV1 )/forced vital capacity (FVC) < 0.70 and the lower limit of normal of FEV1 /FVC. A total of 1743 subjects completed the interview; 1540 performed acceptable spirometry. COPD prevalence was 20.1% (n = 309; ranging from 11.0% in Venezuela to 29.6% in Argentina) when defined using post-BD FEV1 /FVC < 0.70, and 14.7% (n = 226; ranging from 8.3% in Venezuela to 21.8% in Colombia) using the lower limit of normal. Logistic regression analysis for both definitions showed that the risk of COPD was significantly higher for persons >50 years, heavy smokers (>30 pack-years), with dyspnoea, and having prior spirometry. A simple score and a weighted score constructed using the following predictive factors: gender, age, pack-years smoking, dyspnoea, sputum, cough and spirometry, had a mean accuracy for detecting COPD (post-BD FEV1 /FVC < 0.70) of 76% and 79% for the simple and weighted scores, respectively. This simple seven-item score is an accurate screening tool to select subjects for spirometry in primary care. © 2016 Asian Pacific Society of Respirology.
Ronaldson, Sarah J; Dyson, Lisa; Clark, Laura; Hewitt, Catherine E; Torgerson, David J; Cooper, Brendan G; Kearney, Matt; Laughey, William; Raghunath, Raghu; Steele, Lisa; Rhodes, Rebecca; Adamson, Joy
2018-06-01
Early identification of chronic obstructive pulmonary disease (COPD) results in patients receiving appropriate management for their condition at an earlier stage in their disease. The determining the optimal approach to identifying individuals with chronic obstructive pulmonary disease (DOC) study was a case-finding study to enhance early identification of COPD in primary care, which evaluated the diagnostic accuracy of a series of simple lung function tests and symptom-based case-finding questionnaires. Current smokers aged 35 or more were invited to undertake a series of case-finding tools, which comprised lung function tests (specifically, spirometry, microspirometry, peak flow meter, and WheezoMeter) and several case-finding questionnaires. The effectiveness of these tests, individually or in combination, to identify small airways obstruction was evaluated against the gold standard of spirometry, with the quality of spirometry tests assessed by independent overreaders. The study was conducted with general practices in the Yorkshire and Humberside area, in the UK. Six hundred eighty-one individuals met the inclusion criteria, with 444 participants completing their study appointments. A total of 216 (49%) with good-quality spirometry readings were included in the analysis. The most effective case-finding tools were found to be the peak flow meter alone, the peak flow meter plus WheezoMeter, and microspirometry alone. In addition to the main analysis, where the severity of airflow obstruction was based on fixed ratios and percent of predicted values, sensitivity analyses were conducted by using lower limit of normal values. This research informs the choice of test for COPD identification; case-finding by use of the peak flow meter or microspirometer could be used routinely in primary care for suspected COPD patients. Only those testing positive to these tests would move on to full spirometry, thereby reducing unnecessary spirometric testing. © 2018 John Wiley & Sons, Ltd.
Heijkenskjöld Rentzhog, C; Janson, C; Berglund, L; Borres, M P; Nordvall, L; Alving, K; Malinovschi, A
2017-12-01
Classic spirometry is effort dependent and of limited value in assessing small airways. Peripheral airway involvement, and relation to poor control, in asthma, has been highlighted recently. Forced oscillation technique (FOT) offers an effort-independent assessment of overall and peripheral lung mechanics. We studied the association between lung function variables, obtained either by spirometry or multifrequency (5, 11 and 19 Hz) FOT, and asthma diagnosis and control. Spirometry measures, resistance at 5 (R5) and 19 Hz (R19), reactance at 5 Hz (X5), resonant frequency (f res ), resistance difference between 5-19 Hz (R5-R19) and Asthma Control Test scores were determined in 234 asthmatic and 60 healthy subjects (aged 13-39 years). We used standardized lung function variables in logistic regression analyses, unadjusted and adjusted for age, height, gender and weight. Lower FEV 1 /FVC (OR [95% CI] 0.47 [0.32, 0.69]) and FEF 50 (0.62 [0.46, 0.85]) per standard deviation increase, and higher R5 (3.31 [1.95, 5.62]) and R19 (2.54 [1.65, 3.91]) were associated with asthma diagnosis. Independent predictive effects of FEV 1 /FVC and R5 or R19, respectively, were found for asthma diagnosis. Lower FEV 1 /FVC and altered peripheral FOT measures (X5, f res and R5-R19) were associated with uncontrolled asthma (P-values < .05). Resistance FOT measures were equally informative as spirometry, related to asthma diagnosis, and, furthermore, offered additive information to FEV 1 /FVC, supporting a complementary role for FOT. Asthma control was related to FOT measures of peripheral airways, suggesting a potential use in identifying such involvement. Further studies are needed to determine a clinical value and relevant reference values in children, for the multifrequency FOT measurements. © 2017 John Wiley & Sons Ltd.
Cushen, Breda; McCormack, Niamh; Hennigan, Kerrie; Sulaiman, Imran; Costello, Richard W; Deering, Brenda
2016-10-01
One-third of patients with an exacerbation of Chronic Obstructive Pulmonary Disease(COPD) are re-hospitalised at 90 days. Exacerbation recovery is associated with reductions in lung hyperinflation and improvements in symptoms and physical activity. We assessed the feasibility of monitoring these clinical parameters in the home. We hypothesised that the degree of change in spirometry and lung volumes differs between those who had an uneventful recovery and those who experienced a further exacerbation. Hospitalised patients with an acute exacerbation of COPD referred for a supported discharge program participated in the study. Spirometry and Inspiratory Vital Capacity(IVC) were measured in the home at Days 1, 14 and 42 post-discharge. Patients also completed Medical Research Council(MRC), Borg and COPD Assessment Test(CAT) scores and were provided with a tri-axial accelerometer. Any new exacerbation events were recorded. Sixty-five patients with 72 exacerbation episodes were recruited. Fifty percent experienced a second exacerbation. Adequate IVC measurements were achieved by 90%, while only 70% completed spirometry. Uneventful recovery was accompanied by significant improvements in physiological measurements at day14, improved symptom scores and step count, p < 0.05. Failure of MRC to improve was predictive of re-exacerbation(Area Under Receiver Operating Curve(AUROC) 0.6713) with improvements in FEV 1 ≥100 ml(AUROC 0.6613) and mean daily step count ≥396 steps(AUROC 0.6381) predictive of recovery. Monitoring the pattern of improvement in spirometry, lung volumes, symptoms and step count following a COPD exacerbation may help to identify patients at risk of re-exacerbation. It is feasible to carry out these assessments in the home as part of a supported discharge programme. Copyright © 2016 Elsevier Ltd. All rights reserved.
A low cost, customizable turbidostat for use in synthetic circuit characterization.
Takahashi, Chris N; Miller, Aaron W; Ekness, Felix; Dunham, Maitreya J; Klavins, Eric
2015-01-16
Engineered biological circuits are often disturbed by a variety of environmental factors. In batch culture, where the majority of synthetic circuit characterization occurs, environmental conditions vary as the culture matures. Turbidostats are powerful characterization tools that provide static culture environments; however, they are often expensive, especially when purchased in custom configurations, and are difficult to design and construct in a lab. Here, we present a low cost, open source multiplexed turbidostat that can be manufactured and used with minimal experience in electrical or software engineering. We demonstrate the utility of this system to profile synthetic circuit behavior in S. cerevisiae. We also demonstrate the flexibility of the design by showing that a fluorometer can be easily integrated.
Charging system and method for multicell storage batteries
Cox, Jay A.
1978-01-01
A battery-charging system includes a first charging circuit connected in series with a plurality of battery cells for controlled current charging. A second charging circuit applies a controlled voltage across each individual cell for equalization of the cells to the fully charged condition. This controlled voltage is determined at a level above the fully charged open-circuit voltage but at a sufficiently low level to prevent corrosion of cell components by electrochemical reaction. In this second circuit for cell equalization, a transformer primary receives closely regulated, square-wave voltage which is coupled to a plurality of equal secondary coil windings. Each secondary winding is connected in parallel to each cell of a series-connected pair of cells through half-wave rectifiers and a shared, intermediate conductor.
Paget, J.A.
1963-05-14
A structure for monitoring the structural continuity of a control rod foi a neutron reactor is presented. A electric conductor readily breakable under mechanical stress is fastened along the length of the control rod at a plurality of positions and forms a closed circuit with remote electrical components responsive to an open circuit. A portion of the conductor between the control rod and said components is helically wound to allow free and normally unrestricted movement of the segment of conductor secured to the control rod relative to the remote components. Any break in the circuit is indicative of control rod breakage. (AEC)
Solid-state circuit breaker with current-limiting characteristic using a superconducting coil
Boenig, H.J.
1982-08-16
A thyristor bridge interposes an ac source and a load. A series connected DC source and superconducting coil within the bridge biases the thyristors thereof so as to permit bidirectional ac current flow therethrough under normal operating conditions. Upon a fault condition a control circuit triggers the thyristors so as to reduce ac current flow therethrough to zero in less than two eyeles and to open the bridge thereafter. Upon a temporary overload condition the control circuit triggers the thyristors so as to limit ac current flow therethrough to an acceptable level.
Solid-state circuit breaker with current limiting characteristic using a superconducting coil
Boenig, Heinrich J.
1984-01-01
A thyristor bridge interposes an ac source and a load. A series connected DC source and superconducting coil within the bridge biases the thyristors thereof so as to permit bidirectional ac current flow therethrough under normal operating conditions. Upon a fault condition a control circuit triggers the thyristors so as to reduce ac current flow therethrough to zero in less than two cycles and to open the bridge thereafter. Upon a temporary overload condition the control circuit triggers the thyristors so as to limit ac current flow therethrough to an acceptable level.
Process Research On Polycrystalline Silicon Material (PROPSM)
NASA Technical Reports Server (NTRS)
Culik, J. S.; Wohlgemuth, J. H.
1982-01-01
Performance limiting mechanisms in polycrystalline silicon are investigated by fabricating a matrix of solar cells of various thicknesses from polycrystalline silicon wafers of several bulk resistivities. The analysis of the results for the entire matrix indicates that bulk recombination is the dominant factor limiting the short circuit current in large grain (greater than 1 to 2 mm diameter) polycrystalline silicon, the same mechanism that limits the short circuit current in single crystal silicon. An experiment to investigate the limiting mechanisms of open circuit voltage and fill factor for large grain polycrystalline silicon is designed. Two process sequences to fabricate small cells are investigated.
Charge recombination in organic photovoltaic devices with high open-circuit voltages.
Westenhoff, Sebastian; Howard, Ian A; Hodgkiss, Justin M; Kirov, Kiril R; Bronstein, Hugo A; Williams, Charlotte K; Greenham, Neil C; Friend, Richard H
2008-10-15
A detailed charge recombination mechanism is presented for organic photovoltaic devices with a high open-circuit voltage. In a binary blend comprised of polyfluorene copolymers, the performance-limiting process is found to be the efficient recombination of tightly bound charge pairs into neutral triplet excitons. We arrive at this conclusion using optical transient absorption (TA) spectroscopy with visible and IR probes and over seven decades of time resolution. By resolving the polarization of the TA signal, we track the movement of polaronic states generated at the heterojunction not only in time but also in space. It is found that the photogenerated charge pairs are remarkably immobile at the heterojunction during their lifetime. The charge pairs are shown to be subject to efficient intersystem crossing and terminally recombine into F8BT triplet excitons within approximately 40 ns. Long-range charge separation competes rather unfavorably with intersystem crossing--75% of all charge pairs decay into triplet excitons. Triplet exciton states are thermodynamically accessible in polymer solar cells with high open circuit voltage, and we therefore suggest this loss mechanism to be general. We discuss guidelines for the design of the next generation of organic photovoltaic materials where separating the metastable interfacial charge pairs within approximately 40 ns is paramount.
Meta-analysis of Microbial Fuel Cells Using Waste Substrates.
Dowdy, F Ryan; Kawakita, Ryan; Lange, Matthew; Simmons, Christopher W
2018-05-01
Microbial fuel cell experimentation using waste streams is an increasingly popular field of study. One obstacle to comparing studies has been the lack of consistent conventions for reporting results such that meta-analysis can be used for large groups of experiments. Here, 134 unique microbial fuel cell experiments using waste substrates were compiled for analysis. Findings include that coulombic efficiency correlates positively with volumetric power density (p < 0.001), negatively with working volume (p < 0.05), and positively with percentage removal of chemical oxygen demand (p < 0.005). Power density in mW/m 2 correlates positively with chemical oxygen demand loading (p < 0.005), and positively with maximum open-circuit voltage (p < 0.05). Finally, single-chamber versus double-chamber reactor configurations differ significantly in maximum open-circuit voltage (p < 0.005). Multiple linear regression to predict either power density or maximum open-circuit voltage produced no significant models due to the amount of multicollinearity between predictor variables. Results indicate that statistically relevant conclusions can be drawn from large microbial fuel cell datasets. Recommendations for future consistency in reporting results following a MIAMFCE convention (Minimum Information About a Microbial Fuel Cell Experiment) are included.
NASA Astrophysics Data System (ADS)
Zhang, Yanxiang; Chen, Yu; Yan, Mufu
2017-07-01
The open circuit voltage (OCV) of solid oxide fuel cells is generally overestimated by the Nernst equation and the Wagner equation, due to the polarization losses at electrodes. Considering both the electronic conduction of electrolyte and the electrode polarization losses, we express the OCV as an implicit function of the characteristic oxygen pressure of electrolyte (p* [atm], at which the electronic and ionic conductivities are the same), and the relative polarization resistance of electrodes (rc = Rc/Ri and ra = Ra/Ri, where Ri/c/a [Ωcm2] denotes the ionic resistance of electrolyte, and the polarization resistances of cathode and anode, respectively). This equation approaches to the Wagner equation when the electrodes are highly active (rc and ra → 0), and approaches to the Nernst equation when the electrolyte is a purely ionic conductor (p* → 0). For the fuel cells whose OCV is well below the prediction of the Wagner equation, for example with thin doped ceria electrolyte, it is demonstrated that the combination of OCV and impedance spectroscopy measurements allows the determination of p*, Rc and Ra. This equation can serve as a simple yet powerful tool to study the internal losses in the cell under open circuit condition.
Song, Yonggui; Su, Dan; Shen, Yuan; Liu, Hongyu; Wang, Li
2017-01-01
A novel open circuit potential biosensor (OCPS) composed of a working electrode and a Ag/AgCl reference electrode was designed for in vivo continuous glucose monitoring in this work. The macroporous carbon derived from kenaf stem (KSC) was used to construct a KSC microelectrode (denoted as KSCME) which was subsequently used to load glucose oxidase (GOD) as the working electrode. The resulting GOD/KSCMEs could catalyze the oxidation of glucose directly to result in changes of the open circuit potential (V oc ) of the OCPS. The V oc of OCPS was dependent on the glucose concentration, showing a linear range of 0.03-10.0 mM (R = 0.999) with a detection limit of 10 μM. In addition, the OCPS exhibited good selectivity for glucose over other common endogenous interferences. The feasibility of the proposed OCPS for glucose detection in mice skin tumors and normal tissue homogenate samples (in vitro experiment) and rat subcutaneous glucose monitoring (in vivo experiment) was also demonstrated with satisfactory results. The biosensor represents a novel example of a superficial cancer diagnostic device, and the proposed OCPS also provides new ideas for the development of a simple and highly selective device for continuous glucose sensing.
NASA Astrophysics Data System (ADS)
Kundu, Sumit; Fowler, Michael W.; Simon, Leonardo C.; Abouatallah, Rami; Beydokhti, Natasha
Fuel cell material durability is an area of extensive research today. Chemical degradation of the ionomer membrane is one important degradation mechanism leading to overall failure of fuel cells. This study examined the effects of relative humidity on the chemical degradation of the membrane during open circuit voltage testing. Five Gore™ PRIMEA ® series 5510 catalyst coated membranes were degraded at 100%, 75%, 50%, and 20% RH. Open circuit potential and cumulative fluoride release were monitored over time. Additionally scanning electron microscopy images were taken at end of the test. The results showed that with decreasing RH fluoride release rate increased as did performance degradation. This was attributed to an increase in gas crossover with a decrease in RH. Further, it is also shown that interruptions in testing may heavily influence cumulative fluoride release measurements where frequent stoppages in testing will cause fluoride release to be underestimated. SEM analysis shows that degradation occurred in the ionomer layer close to the cathode catalyst. A chemical degradation model of the ionomer membrane was used to model the results. The model was able to predict fluoride release trends, including the effects of interruptions, showing that changes in gas crossover with RH could explain the experimental results.
Al-Mutairi, Fouad H; Fallows, Stephen J; Abukhudair, Waleed A; Islam, Baharul B; Morris, Michael M
2012-11-01
To assess the effect of early use of continuous positive airway pressure (CPAP) therapy to treat or prevent acute atelectasis in post-operative cardiac patients particularly smokers and elderly patients. A pilot study suggested enrolling at least 32 participants in each group to be significant. One hundred and eight patients from King Fahd Armed Forces Hospital, Jeddah, Kingdom of Saudi Arabia who met the inclusion criteria participated in this study conducted between March 2010 and March 2011. The participants were divided randomly into 3 groups, incentive spirometry (IS) therapy, and CPAP therapy every 2 (CPAP 2 hrs), or 4 hours (CPAP 4 hrs). Inspiratory capacity (IC) was used to compare the 3 therapy regimes. Simultaneously, respiratory rate (RR), heart rate (HR) and oxygen saturation (SpO2) were measured for all groups. Failure was defined as requiring intubation, bi-level positive airway pressure, or added chest physiotherapy. Thirty-six patients participated in each group (98 male and 10 female, with a mean age of 62+/-9.3 years). The IC increased significantly in the CPAP 2 hrs group when compared with the control group or the CPAP 4hrs group. The SpO2 decreased significantly in the control group and the CPAP 4 hrs groups when compared with the CPAP 2 hrs group. Also, there were no significant differences in RR and HR between all groups. Early use of CPAP via mask therapy for half an hour every 2 hours had better outcomes to re-open collapsed alveoli after cardiac surgery.
Effect of indacaterol on arterial blood gases in patients suffering from acute exacerbation of COPD.
Rogliani, Paola; Ora, Josuel; Ciaprini, Chiara; Senis, Lucia; Stirpe, Emanuele; Cazzola, Mario
2014-02-01
The administration of β2-agonists to patients with airways obstruction often results in transient decrease in PaO2 despite concomitant bronchodilation. This effect is potentially dangerous for patients suffering from acute exacerbation of COPD (AECOPD). In this study, we investigated the effect of indacaterol 150 μg and 300 μg on the arterial blood gas tensions of hospitalised patients with AECOPD. We explored the acute effects on arterial blood gases and spirometry of two doses of indacaterol Breezhaler (150 and 300 μg) in 12 patients hospitalised because of an AECOPD in 2 non-consecutive days under open-label, randomized, crossover conditions, with blind evaluation. Blood specimens were taken just before the inhalation and at 15, 30, 60, 120, 240 and 360 min after inhalation of each treatment, and spirometry was performed at the same time points. Both doses of indacaterol did not cause significant changes in blood gases, although some patients with relatively well-preserved PaO2 presented transient episodes of oxygen desaturation that normalize spontaneously in a very short time. Moreover, they induced a significant mean increase in FEV1 and FVC, although the improvement caused by indacaterol 300 μg was larger. Indacaterol up to 300 μg is a potent bronchodilator that may induce small, transient decrease in PaO2 mainly in patients with relatively well-preserved PaO2. There appeared to be no clinical consequences of these PaO2 abnormalities in patients suffering from AECOPD. Copyright © 2013. Published by Elsevier Ltd.
Occupational Survey Report, Cardiopulmonary Laboratory, AFSC 4H0X1, OSSN: 2541
2004-02-01
patients within facility 97 E0211 Set up humidifiers 97 E0175 Instruct patients in use of incentive spirometers 97 A0031 Obtain sputum samples 97 A0026...D0137 Calibrate pulmonary function testing equipment 100 D0150 Perform routine spirometry tests 100 D0146 Perform lung diffusion tests 100 A0042 Perform...consultations, or procedures 31 D0150 Perform routine spirometry tests 23 35 TABLE A2 REPRESENTATIVE TASKS PERFORMED BY MEMBERS IN THE SUPERVISION AND
Elongated uvula and diagnostic utility of spirometry in upper airway obstruction
Paliwal, Rajiv; Patel, Satish; Patel, Purvesh; Soni, Hiren
2010-01-01
Elongated uvula is relatively an uncommon condition. Upper airway obstruction is often a missed complication of such a rare condition. Clinical presentations of upper airway obstruction often mimic asthma. Hence it is very easily mis-diagnosed as asthma. Spirometry offers a very simple test to diagnose upper airway obstruction very early and easily. Once diagnosed, the management of elongated uvula, almost exclusively, is surgical excision leading to total cure. Here is a case report of such a rare condition. PMID:20539769
Molecular electronics in pinnae of Mimosa pudica
Foster, Justin C; Markin, Vladislav S
2010-01-01
Bioelectrochemical circuits operate in all plants including the sensitive plant Mimosa pudica Linn. The activation of biologically closed circuits with voltage gated ion channels can lead to various mechanical, hydrodynamical, physiological, biochemical and biophysical responses. Here the biologically closed electrochemical circuit in pinnae of Mimosa pudica is analyzed using the charged capacitor method for electrostimulation at different voltages. Also the equivalent electrical scheme of electrical signal transduction inside the plant's pinna is evaluated. These circuits remain linear at small potentials not exceeding 0.5 V. At higher potentials the circuits become strongly non-linear pointing to the opening of ion channels in plant tissues. Changing the polarity of electrodes leads to a strong rectification effect and to different kinetics of a capacitor. These effects can be caused by a redistribution of K+, Cl−, Ca2+ and H+ ions through voltage gated ion channels. The electrical properties of Mimosa pudica were investigated and equivalent electrical circuits within the pinnae were proposed to explain the experimental data. PMID:20448476
Molecular electronics in pinnae of Mimosa pudica.
Volkov, Alexander G; Foster, Justin C; Markin, Vladislav S
2010-07-01
Bioelectrochemical circuits operate in all plants including the sensitive plant Mimosa pudica Linn. The activation of biologically closed circuits with voltage gated ion channels can lead to various mechanical, hydrodynamical, physiological, biochemical, and biophysical responses. Here the biologically closed electrochemical circuit in pinnae of Mimosa pudica is analyzed using the charged capacitor method for electrostimulation at different voltages. Also the equivalent electrical scheme of electrical signal transduction inside the plant's pinna is evaluated. These circuits remain linear at small potentials not exceeding 0.5 V. At higher potentials the circuits become strongly non-linear pointing to the opening of ion channels in plant tissues. Changing the polarity of electrodes leads to a strong rectification effect and to different kinetics of a capacitor. These effects can be caused by a redistribution of K(+), Cl(-), Ca(2+), and H(+) ions through voltage gated ion channels. The electrical properties of Mimosa pudica were investigated and equivalent electrical circuits within the pinnae were proposed to explain the experimental data.
Lung Function before and Two Days after Open-Heart Surgery.
Urell, Charlotte; Westerdahl, Elisabeth; Hedenström, Hans; Janson, Christer; Emtner, Margareta
2012-01-01
Reduced lung volumes and atelectasis are common after open-heart surgery, and pronounced restrictive lung volume impairment has been found. The aim of this study was to investigate factors influencing lung volumes on the second postoperative day. Open-heart surgery patients (n = 107, 68 yrs, 80% male) performed spirometry both before surgery and on the second postoperative day. The factors influencing postoperative lung volumes and decrease in lung volumes were investigated with univariate and multivariate analyses. Associations between pain (measured by numeric rating scale) and decrease in postoperative lung volumes were calculated with Spearman rank correlation test. Lung volumes decreased by 50% and were less than 40% of the predictive values postoperatively. Patients with BMI >25 had lower postoperative inspiratory capacity (IC) (33 ± 14% pred.) than normal-weight patients (39 ± 15% pred.), (P = 0.04). More pain during mobilisation was associated with higher decreases in postoperative lung volumes (VC: r = 0.33, P = 0.001; FEV(1): r = 0.35, P ≤ 0.0001; IC: r = 0.25, P = 0.01). Patients with high BMI are a risk group for decreased postoperative lung volumes and should therefore receive extra attention during postoperative care. As pain is related to a larger decrease in postoperative lung volumes, optimal pain relief for the patients should be identified.
Lung Function before and Two Days after Open-Heart Surgery
Urell, Charlotte; Westerdahl, Elisabeth; Hedenström, Hans; Janson, Christer; Emtner, Margareta
2012-01-01
Reduced lung volumes and atelectasis are common after open-heart surgery, and pronounced restrictive lung volume impairment has been found. The aim of this study was to investigate factors influencing lung volumes on the second postoperative day. Open-heart surgery patients (n = 107, 68 yrs, 80% male) performed spirometry both before surgery and on the second postoperative day. The factors influencing postoperative lung volumes and decrease in lung volumes were investigated with univariate and multivariate analyses. Associations between pain (measured by numeric rating scale) and decrease in postoperative lung volumes were calculated with Spearman rank correlation test. Lung volumes decreased by 50% and were less than 40% of the predictive values postoperatively. Patients with BMI >25 had lower postoperative inspiratory capacity (IC) (33 ± 14% pred.) than normal-weight patients (39 ± 15% pred.), (P = 0.04). More pain during mobilisation was associated with higher decreases in postoperative lung volumes (VC: r = 0.33, P = 0.001; FEV1: r = 0.35, P ≤ 0.0001; IC: r = 0.25, P = 0.01). Patients with high BMI are a risk group for decreased postoperative lung volumes and should therefore receive extra attention during postoperative care. As pain is related to a larger decrease in postoperative lung volumes, optimal pain relief for the patients should be identified. PMID:22924127
Genetically Encoded Catalytic Hairpin Assembly for Sensitive RNA Imaging in Live Cells.
Mudiyanselage, Aruni P K K Karunanayake; Yu, Qikun; Leon-Duque, Mark A; Zhao, Bin; Wu, Rigumula; You, Mingxu
2018-06-26
DNA and RNA nanotechnology has been used for the development of dynamic molecular devices. In particular, programmable enzyme-free nucleic acid circuits, such as catalytic hairpin assembly, have been demonstrated as useful tools for bioanalysis and to scale up system complexity to an extent beyond current cellular genetic circuits. However, the intracellular functions of most synthetic nucleic acid circuits have been hindered by challenges in the biological delivery and degradation. On the other hand, genetically encoded and transcribed RNA circuits emerge as alternative powerful tools for long-term embedded cellular analysis and regulation. Herein, we reported a genetically encoded RNA-based catalytic hairpin assembly circuit for sensitive RNA imaging inside living cells. The split version of Broccoli, a fluorogenic RNA aptamer, was used as the reporter. One target RNA can catalytically trigger the fluorescence from tens-to-hundreds of Broccoli. As a result, target RNAs can be sensitively detected. We have further engineered our circuit to allow easy programming to image various target RNA sequences. This design principle opens the arena for developing a large variety of genetically encoded RNA circuits for cellular applications.
Capillarics: pre-programmed, self-powered microfluidic circuits built from capillary elements.
Safavieh, Roozbeh; Juncker, David
2013-11-07
Microfluidic capillary systems employ surface tension effects to manipulate liquids, and are thus self-powered and self-regulated as liquid handling is structurally and chemically encoded in microscale conduits. However, capillary systems have been limited to perform simple fluidic operations. Here, we introduce complex capillary flow circuits that encode sequential flow of multiple liquids with distinct flow rates and flow reversal. We first introduce two novel microfluidic capillary elements including (i) retention burst valves and (ii) robust low aspect ratio trigger valves. These elements are combined with flow resistors, capillary retention valves, capillary pumps, and open and closed reservoirs to build a capillary circuit that, following sample addition, autonomously delivers a defined sequence of multiple chemicals according to a preprogrammed and predetermined flow rate and time. Such a circuit was used to measure the concentration of C-reactive protein. This work illustrates that as in electronics, complex capillary circuits may be built by combining simple capillary elements. We define such circuits as "capillarics", and introduce symbolic representations. We believe that more complex circuits will become possible by expanding the library of building elements and formulating abstract design rules.
Basic study of entire whole-body PET scanners based on the OpenPET geometry
NASA Astrophysics Data System (ADS)
Yoshida, Eiji; Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo
2010-09-01
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.
Mauger, Scott A.; Steirer, K. Xerxes; Boe, Jonas; ...
2016-01-19
Here, this work focuses on the role of humidity in the formation of ZnO thin films from a reactive diethylzinc precursor solution for use as the electron contact layer (ECL) in organic photovoltaic (OPV) devices. This method is well suited for flexible devices because the films are annealed at 120 °C, making the process compatible with polymer substrates. ZnO films were prepared by spin coating and annealing at different relative humidity (RH) levels. It is found that RH during coating and annealing affects the chemical and physical properties of the ZnO films. Using x-ray photoelectron spectroscopy it is found thatmore » increasing RH during the formation steps produces a more stoichiometric oxide and a higher Zn/O ratio. Spectroscopic ellipsometry data shows a small decrease in the optical band gap with increased humidity, consistent with a more stoichiometric oxide. Kelvin probe measurements show that increased RH during formation results in a larger work function (i.e. further from vacuum). Consistent with these data, but counter to what might be expected, when these ZnO films are used as ECLs in OPV devices those with ZnO ECLs processed in low RH (less stoichiometric) had higher power conversion efficiency than those with high-RH processed ZnO due to improved open-circuit voltage. The increase in open-circuit voltage with decreasing humidity was observed with two different donor polymers and fullerene acceptors, which shows the trend is due to changes in ZnO. The observed changes in open-circuit voltage follow the same trend as the ZnO work function indicating that the increase in open-circuit voltage with decreasing humidity is the result of improved energetics at the interface between the bulk-heterojunction and the ZnO layer due to a vacuum level shift.« less
Electronic logic for enhanced switch reliability
Cooper, J.A.
1984-01-20
A logic circuit is used to enhance redundant switch reliability. Two or more switches are monitored for logical high or low output. The output for the logic circuit produces a redundant and fail-safe representation of the switch outputs. When both switch outputs are high, the output is high. Similarly, when both switch outputs are low, the logic circuit's output is low. When the output states of the two switches do not agree, the circuit resolves the conflict by memorizing the last output state which both switches were simultaneously in and produces the logical complement of this output state. Thus, the logic circuit of the present invention allows the redundant switches to be treated as if they were in parallel when the switches are open and as if they were in series when the switches are closed. A failsafe system having maximum reliability is thereby produced.
High on food: the interaction between the neural circuits for feeding and for reward.
Liu, Jing-Jing; Mukherjee, Diptendu; Haritan, Doron; Ignatowska-Jankowska, Bogna; Liu, Ji; Citri, Ami; Pang, Zhiping P
2015-04-01
Hunger, mostly initiated by a deficiency in energy, induces food seeking and intake. However, the drive toward food is not only regulated by physiological needs, but is motivated by the pleasure derived from ingestion of food, in particular palatable foods. Therefore, feeding is viewed as an adaptive motivated behavior that involves integrated communication between homeostatic feeding circuits and reward circuits. The initiation and termination of a feeding episode are instructed by a variety of neuronal signals, and maladaptive plasticity in almost any component of the network may lead to the development of pathological eating disorders. In this review we will summarize the latest understanding of how the feeding circuits and reward circuits in the brain interact. We will emphasize communication between the hypothalamus and the mesolimbic dopamine system and highlight complexities, discrepancies, open questions and future directions for the field.
Reconfigurable Complementary Logic Circuits with Ambipolar Organic Transistors
Yoo, Hocheon; Ghittorelli, Matteo; Smits, Edsger C. P.; Gelinck, Gerwin H.; Lee, Han-Koo; Torricelli, Fabrizio; Kim, Jae-Joon
2016-01-01
Ambipolar organic electronics offer great potential for simple and low-cost fabrication of complementary logic circuits on large-area and mechanically flexible substrates. Ambipolar transistors are ideal candidates for the simple and low-cost development of complementary logic circuits since they can operate as n-type and p-type transistors. Nevertheless, the experimental demonstration of ambipolar organic complementary circuits is limited to inverters. The control of the transistor polarity is crucial for proper circuit operation. Novel gating techniques enable to control the transistor polarity but result in dramatically reduced performances. Here we show high-performance non-planar ambipolar organic transistors with electrical control of the polarity and orders of magnitude higher performances with respect to state-of-art split-gate ambipolar transistors. Electrically reconfigurable complementary logic gates based on ambipolar organic transistors are experimentally demonstrated, thus opening up new opportunities for ambipolar organic complementary electronics. PMID:27762321
Reconfigurable Complementary Logic Circuits with Ambipolar Organic Transistors.
Yoo, Hocheon; Ghittorelli, Matteo; Smits, Edsger C P; Gelinck, Gerwin H; Lee, Han-Koo; Torricelli, Fabrizio; Kim, Jae-Joon
2016-10-20
Ambipolar organic electronics offer great potential for simple and low-cost fabrication of complementary logic circuits on large-area and mechanically flexible substrates. Ambipolar transistors are ideal candidates for the simple and low-cost development of complementary logic circuits since they can operate as n-type and p-type transistors. Nevertheless, the experimental demonstration of ambipolar organic complementary circuits is limited to inverters. The control of the transistor polarity is crucial for proper circuit operation. Novel gating techniques enable to control the transistor polarity but result in dramatically reduced performances. Here we show high-performance non-planar ambipolar organic transistors with electrical control of the polarity and orders of magnitude higher performances with respect to state-of-art split-gate ambipolar transistors. Electrically reconfigurable complementary logic gates based on ambipolar organic transistors are experimentally demonstrated, thus opening up new opportunities for ambipolar organic complementary electronics.
Fischer, Hendrik S; Ullrich, Tim L; Bührer, Christoph; Czernik, Christoph; Schmalisch, Gerd
2017-02-01
Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and humidity. The model features the insertion of a heated humidifier between an active model lung and an oropharyngeal head model to simulate the recurrent expiration of heated, humidified air. During unsupported breathing, physiological temperature and humidity were attained inside the model oropharynx, and mouth opening had no significant effect on oropharyngeal temperature and humidity. During binasal CPAP, the impact of mouth opening was investigated using three different scenarios: no conditioning in the CPAP circuit, heating only, and heated humidification. Mouth opening had a strong negative impact on oropharyngeal humidification in all tested scenarios, but heated humidification in the CPAP circuit maintained clinically acceptable humidity levels regardless of closed or open mouths. The model can be used to test new equipment for use with CPAP, and to investigate the effects of other methods of non-invasive respiratory support on gas conditioning in the presence of leaks. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Wilkins, Matthew M.; Gupta, James; Jaouad, Abdelatif; Bouzazi, Boussairi; Fafard, Simon; Boucherif, Abderraouf; Valdivia, Christopher E.; Arès, Richard; Aimez, Vincent; Schriemer, Henry P.; Hinzer, Karin
2017-04-01
Four-junction solar cells for space and terrestrial applications require a junction with a band gap of ˜1 eV for optimal performance. InGaAsN or InGaAsN(Sb) dilute nitride junctions have been demonstrated for this purpose, but in achieving the 14 mA/cm2 short-circuit current needed to match typical GaInP and GaAs junctions, the open-circuit voltage (VOC) and fill factor of these junctions are compromised. In multijunction devices incorporating materials with short diffusion lengths, we study the use of thin junctions to minimize sensitivity to varying material quality and ensure adequate transmission into lower junctions. An n-i-p device with 0.65-μm absorber thickness has sufficient short-circuit current, however, it relies less heavily on field-aided collection than a device with a 1-μm absorber. Our standard cell fabrication process, which includes a rapid thermal anneal of the contacts, yields a significant improvement in diffusion length and device performance. By optimizing a four-junction cell around a smaller 1-sun short-circuit current of 12.5 mA/cm2, we produced an InGaAsN(Sb) junction with open-circuit voltage of 0.44 V at 1000 suns (1 sun=100 mW/cm2), diode ideality factor of 1.4, and sufficient light transmission to allow >12.5 mA/cm2 in all four subcells.
The scientific basis for postoperative respiratory care.
Branson, Richard D
2013-11-01
Postoperative pulmonary complications (PPCs) are common and expensive. Costs, morbidity, and mortality are higher with PPCs than with cardiac or thromboembolic complications. Preventing and treating PPCs is a major focus of respiratory therapists, using a wide variety of techniques and devices, including incentive spirometry, CPAP, positive expiratory pressure, intrapulmonary percussive ventilation, and chest physical therapy. The scientific evidence for these techniques is lacking. CPAP has some evidence of benefit in high risk patients with hypoxemia. Incentive spirometry is used frequently, but the evidence suggests that incentive spirometry alone has no impact on PPC. Chest physical therapy, which includes mechanical clapping and postural drainage, appears to worsen atelectasis secondary to pain and splinting. As with many past respiratory therapy techniques, the profession needs to take a hard look at these techniques and work to provide only practices based on good evidence. The idea of a PPC bundle has merit and should be studied in larger, multicenter trials. Additionally, intraoperative ventilation may play a key role in the development of PPCs and should receive greater attention.
Respiratory effects of diesel exhaust in salt miners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gamble, J.F.; Jones, W.G.
1983-09-01
The respiratory health of 259 white males working at 5 salt (NaCl) mines was assessed by questionnaire, chest radiographs, and air and He-O/sup 2/ spirometry. Response variables were symptoms, pneumoconiosis, and spirometry. Predictor variables included age, height, smoking, mine, and tenure in diesel-exposed jobs. The purpose was to assess the association of response measures of respiratory health with exposure to diesel exhaust. There were only 2 cases of Grade 1 pneumoconiosis, so no further analysis was done. Comparisons within the study population showed a statistically significant dose-related association of phlegm and diesel exposure. There was a nonsignificant trend for coughmore » and dyspnea, and no association with spirometry. Age- and smoking-adjusted rates of cough, phlegm, and dyspnea were 145, 159, and 93% of an external comparison population. Percent predicted flow rates showed statistically significant reductions, but the reductions were small and there were no dose-response relations. Percent predicted FEV1 and FVC were about 96% of predicted.« less
[The NHG guidelines 'Adult asthma' and 'COPD'].
Geijer, Roeland M M; Tuut, Mariska K; in't Veen, Johannes C C M; Broekhuizen, Berna D L; Chavannes, Niels H; Smeele, Ivo J M
2015-01-01
The Dutch College of General Practitioners (NHG) guidelines 'Adult asthma' and 'COPD' have been revised. New spirometry reference values from the Global Lung Function Initiative are recommended. Airway obstruction is defined as a FEV1/FVC ratio below the 5th percentile for the reference population. Spirometry for diagnosis takes place without use of patients' inhaled medication and consists of measurements before and after standardized bronchodilation. In monitoring spirometry, patients continue using inhaled medication and standardized bronchodilation is not indicated. The goal of asthma management is optimal asthma control, tailored to individual goals. The most important non-drug intervention in asthma and COPD is to recommend stopping smoking. The goal of COPD management is to limit symptoms, improve exercise capacity and quality of life, and reduce the burden of disease. Inhaled corticosteroids are usually not indicated in COPD treatment. Patients with comorbid asthma and COPD are treated with non-drug interventions according to the COPD guideline and with medication according to the asthma guideline.
3D Printed Fluidic Hardware for DNA Assembly
2015-04-10
A3909 stepper motor driver, were soldered onto the milled circuit board (Supplementary Figure 8). Custom Arduino - based firmware was written to take...initiatives such as the FabLab Foundation10. Access to digital fabrication tools and open electronics, such as Arduino and Raspberry Pi, enables access to...hardware for assembly of DNA- based genetic circuits. Solid-phase DNA synthesis has declined in price, enabling researchers to routinely design and
Not Available
1981-01-29
Temperature profiles at elevated temperature conditions are monitored by use of an elongated device having two conductors spaced by the minimum distance required to normally maintain an open circuit between them. The melting point of one conductor is selected at the elevated temperature being detected, while the melting point of the other is higher. As the preselected temperature is reached, liquid metal will flow between the conductors creating short circuits which are detectable as to location.