Interchange Slip-Running Reconnection and Sweeping SEP-Beams
NASA Technical Reports Server (NTRS)
Masson, S.; Aulanier, G.; Pariat, E.; Klein, K.-L.
2011-01-01
We present a new model to explain how particles, accelerated at a reconnection site that is not magnetically connected to the Earth, could eventually propagate along the well-connected open flux tube. Our model is based on the results of a low-beta resistive magnetohydrodynamics simulation of a three-dimensional line-tied and initially current-free bipole, that is embedded in a non-uniform open potential field. The topology of this configuration is that of an asymmetric coronal null-point, with a closed fan surface and an open outer spine. When driven by slow photospheric shearing motions, field lines, initially fully anchored below the fan dome, reconnect at the null point, and jump to the open magnetic domain. This is the standard interchange mode as sketched and calculated in 2D. The key result in 3D is that, reconnected open field lines located in the vicinity of the outer spine, keep reconnecting continuously, across an open quasi-separatrix layer, as previously identified for non-open-null-point reconnection. The apparent slipping motion of these field lines leads to form an extended narrow magnetic flux tube at high altitude. Because of the slip-running reconnection, we conjecture that if energetic particles would be travelling through, or be accelerated inside, the diffusion region, they would be successively injected along continuously reconnecting field lines that are connected farther and farther from the spine. At the scale of the full Sun, owing to the super-radial expansion of field lines below 3 solar radius, such energetic particles could easily be injected in field lines slipping over significant distances, and could eventually reach the distant flux tube that is well-connected to the Earth.
Gorzelak, Przemysław; Stolarski, Jarosław; Dubois, Philippe; Kopp, Christophe; Meibom, Anders
2011-10-01
This paper reports the results of the first dynamic labeling experiment with regenerating spines of sea urchins Paracentrotus lividus using the stable isotope ²⁶Mg and NanoSIMS high-resolution isotopic imaging, which provide a direct information about the growth process. Growing spines were labeled twice (for 72 and 24 h, respectively) by increasing the abundance of ²⁶Mg in seawater. The incorporation of ²⁶Mg into the growing spines was subsequently imaged with the NanoSIMS ion microprobe. Stereom trabeculae initially grow as conical micro-spines, which form within less than 1 day. These micro-spines fuse together by lateral outgrowths and form a thin, open meshwork (inner stereom), which is subsequently reinforced by addition of layered thickening deposits (outer stereom). The (longitudinal) growth rate of the inner stereom is ca. 125 μm/day. A single (ca. 1 μm) thickening layer in the stereom trabeculae is deposited during 24h. The thickening process is contemporaneous with the formation micro-spines and involves both longitudinal trabeculae and transverse bridges to a similar degree. Furthermore, the skeleton-forming cells remain active in the previously formed open stereom for at least 10 days, and do not migrate upwards until the end of the thickening process. The experimental capability presented here provides a new way to obtain detailed information about the skeleton formation of a multitude of marine, calcite producing organisms. Copyright © 2011 Elsevier Inc. All rights reserved.
Cao, Lei; Li, Xiaokang; Zhou, Xiaoshu; Li, Yong; Vecchio, Kenneth S; Yang, Lina; Cui, Wei; Yang, Rui; Zhu, Yue; Guo, Zheng; Zhang, Xing
2017-03-22
Sea urchin spines (Heterocentrotus mammillatus), with a hierarchical open-cell structure similar to that of human trabecular bone and superior mechanical property (compressive strength ∼43.4 MPa) suitable for machining to shape, were explored for potential applications of bone defect repair. Finite element analyses reveal that the compressive stress concentrates along the dense growth rings and dissipates through strut structures of the stereoms, indicating that the exquisite mesostructures play an important role in high strength-to-weight ratios. The fracture strength of magnesium-substituted tricalcium phosphate (β-TCMP) scaffolds produced by hydrothermal conversion of urchin spines is about 9.3 MPa, comparable to that of human trabecular bone. New bone forms along outer surfaces of β-TCMP scaffolds after implantation in rabbit femoral defects for one month and grows into the majority of the inner open-cell spaces postoperation in three months, showing tight interface between the scaffold and regenerative bone tissue. Fusion of beagle lumbar facet joints using a Ti-6Al-4V cage and β-TCMP scaffold can be completed within seven months with obvious biodegradation of the β-TCMP scaffold, which is nearly completely degraded and replaced by newly formed bone ten months after implantation. Thus, sea urchin spines suitable for machining to shape have advantages for production of biodegradable artificial grafts for bone defect repair.
Blowout Surge due to Interaction between a Solar Filament and Coronal Loops
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Haidong; Jiang, Yunchun; Yang, Jiayan
2017-06-20
We present an observation of the interaction between a filament and the outer spine-like loops that produces a blowout surge within one footpoint of large-scale coronal loops on 2015 February 6. Based the observation of the AIA 304 and 94 Å, the activated filament is initially embedded below a dome of a fan-spine configuration. Due to the ascending motion, the erupting filament reconnects with the outer spine-like field. We note that the material in the filament blows out along the outer spine-like field to form the surge with a wider spire, and a two-ribbon flare appears at the site ofmore » the filament eruption. In this process, small bright blobs appear at the interaction region and stream up along the outer spine-like field and down along the eastern fan-like field. As a result, a leg of the filament becomes radial and the material in it erupts, while another leg forms the new closed loops. Our results confirm that the successive reconnection occurring between the erupting filament and the coronal loops may lead to a strong thermal/magnetic pressure imbalance, resulting in a blowout surge.« less
ĎuriŠ, ZdenĚk
2018-03-22
Madeirasquilla tuerkayi is described as a new genus and species of the nannosquillid mantis shrimps (Stomatopoda) based on a single specimen collected from Madeira, eastern Atlantic. That specimen is remarkable by a combination of the following morphological characters: rostral plate with three sharp anterior projections; antennal protopod with two mesial and one ventral papillae; cornea subglobular; raptorial claw dactylus with 11 or 12 teeth, and with acute proximal tooth on outer margin; pleonite 6 with strong posterolateral spine and two posteriorly directed sternal spines; telson bearing smooth shield-like dorsal prominence with acute median spine posteriorly; four pairs of fixed primary teeth posteriorly on the telson; outer primary spine of uropodal protopod longer than inner primary spine. The separate position of the new genus is supported also by molecular comparison. A key to the genera of the family Nannosquillidae is proposed.
Functional Morphology of the Mouthparts of the Adult Mediterranean Fruit Fly, Ceratitis capitata
Coronado-Gonzalez, Pablo A.; Vijaysegaran, S.; Robinson, Alan S.
2008-01-01
Food-based attractants incorporating an insecticide are an important component of area-wide control programmes for the Mediterranean fruit fly, Ceratitis capitata (Wiedemann) (Diptera: Tephritidae). This study was carried out to understand the feeding mechanism of adults of this species. Mouthparts of C. capitata are similar in general structure to those of another Tephritid genus, Bactrocera, and have specific structural modifications that determine what adult flies can ingest. The labellum has a series of fine tube-like structures, called pseudotracheae, on its inner surface. Each pseudotrachea leads from the outer margin of the labellum and ends at the prestomum to the oral opening. The pseudotracheae contain fine micropores about 0.5µm in size. During feeding, the oral opening is never exposed to the feeding substrate but the portions of the opposing labellar lobes proximal to the oral opening are flexed against each other and distal portions of the opposing labellar lobes are opened and pressed flat against the feeding substrate or surface. The prestomal spines at the base of each pseudotrachea interlock to form a barrier across the oral opening. Thus entry of large particles directly into the crop and gut through the oral opening is prevented by flexure of the opposing labellar lobes against each other and the interlocking prestomal spines across the oral opening. Only liquids and suspended particles less than 0.5µm in size are sucked through the micropores into the lumen of the pseudotracheae and then pass into the food canal and into the crop and gut. The pseudotracheae of adult C. capitata, particularly along the middle portion of the labellum, have prominent blade-like projections that Bactrocera do not have. These projections are probably an ancestral condition as they were not observed to use them to abrade the plant or feeding surface as has been reported for species in the Tephritid genus, Blepharoneura.
A comparative analysis of minimally invasive and open spine surgery patient education resources.
Agarwal, Nitin; Feghhi, Daniel P; Gupta, Raghav; Hansberry, David R; Quinn, John C; Heary, Robert F; Goldstein, Ira M
2014-09-01
The Internet has become a widespread source for disseminating health information to large numbers of people. Such is the case for spine surgery as well. Given the complexity of spinal surgeries, an important point to consider is whether these resources are easily read and understood by most Americans. The average national reading grade level has been estimated to be at about the 7th grade. In the present study the authors strove to assess the readability of open spine surgery resources and minimally invasive spine surgery resources to offer suggestions to help improve the readability of patient resources. Online patient education resources were downloaded in 2013 from 50 resources representing either traditional open back surgery or minimally invasive spine surgery. Each resource was assessed using 10 scales from Readability Studio Professional Edition version 2012.1. Patient education resources representing traditional open back surgery or minimally invasive spine surgery were all found to be written at a level well above the recommended 6th grade level. In general, minimally invasive spine surgery materials were written at a higher grade level. The readability of patient education resources from spine surgery websites exceeds the average reading ability of an American adult. Revisions may be warranted to increase quality and patient comprehension of these resources to effectively reach a greater patient population.
Soh, Ho Young; Moon, Seong Yong; Ohtsuka, Susumu; Pae, Se Jin; Jeong, Hyeon Gyeong
2013-11-01
A new species of the genus Sarsarietellus from Korean waters, S. orientalis n. sp. is described based on both sexes. This is very closely related to S. suluensis Ohtsuka, Nishida and Machida, 2005 , but is readily distinguished by the following characteristics: in the female (1) narrow head; (2) nearly symmetrical posterior corners of last pedigerous somite, not extending beyond the genital double-somite; (3) antennary endopod slightly longer than the exopod; (4) nearly equal length of three outer spines and the terminal spine of the exopod of the fifth leg, except for the proximal third outer spine; and in the male the left fifth leg with two whip-like setae on the tip of the second exopodal segment not being rotated outside. Sarsarietellus orientalis is the fourth species of the genus Sarsarietellus, while the male of Sarsarietellus species is the first reported. The habitat colonization of arietellids is reconsidered.
Observation of a 3D Magnetic Null Point
DOE Office of Scientific and Technical Information (OSTI.GOV)
Romano, P.; Falco, M.; Guglielmino, S. L.
2017-03-10
We describe high-resolution observations of a GOES B-class flare characterized by a circular ribbon at the chromospheric level, corresponding to the network at the photospheric level. We interpret the flare as a consequence of a magnetic reconnection event that occurred at a three-dimensional (3D) coronal null point located above the supergranular cell. The potential field extrapolation of the photospheric magnetic field indicates that the circular chromospheric ribbon is cospatial with the fan footpoints, while the ribbons of the inner and outer spines look like compact kernels. We found new interesting observational aspects that need to be explained by models: (1)more » a loop corresponding to the outer spine became brighter a few minutes before the onset of the flare; (2) the circular ribbon was formed by several adjacent compact kernels characterized by a size of 1″–2″; (3) the kernels with a stronger intensity emission were located at the outer footpoint of the darker filaments, departing radially from the center of the supergranular cell; (4) these kernels started to brighten sequentially in clockwise direction; and (5) the site of the 3D null point and the shape of the outer spine were detected by RHESSI in the low-energy channel between 6.0 and 12.0 keV. Taking into account all these features and the length scales of the magnetic systems involved in the event, we argue that the low intensity of the flare may be ascribed to the low amount of magnetic flux and to its symmetric configuration.« less
Minimally Invasive versus Open Spine Surgery: What Does the Best Evidence Tell Us?
McClelland, Shearwood; Goldstein, Jeffrey A
2017-01-01
Spine surgery has been transformed significantly by the growth of minimally invasive surgery (MIS) procedures. Easily marketable to patients as less invasive with smaller incisions, MIS is often perceived as superior to traditional open spine surgery. The highest quality evidence comparing MIS with open spine surgery was examined. A systematic review of randomized controlled trials (RCTs) involving MIS versus open spine surgery was performed using the Entrez gateway of the PubMed database for articles published in English up to December 28, 2015. RCTs and systematic reviews of RCTs of MIS versus open spine surgery were evaluated for three particular entities: Cervical disc herniation, lumbar disc herniation, and posterior lumbar fusion. A total of 17 RCTs were identified, along with six systematic reviews. For cervical disc herniation, MIS provided no difference in overall function, arm pain relief, or long-term neck pain. In lumbar disc herniation, MIS was inferior in providing leg/low back pain relief, rehospitalization rates, quality of life improvement, and exposed the surgeon to >10 times more radiation in return for shorter hospital stay and less surgical site infection. In posterior lumbar fusion, MIS transforaminal lumbar interbody fusion (TLIF) had significantly reduced 2-year societal cost, fewer medical complications, reduced time to return to work, and improved short-term Oswestry Disability Index scores at the cost of higher revision rates, higher readmission rates, and more than twice the amount of intraoperative fluoroscopy. The highest levels of evidence do not support MIS over open surgery for cervical or lumbar disc herniation. However, MIS TLIF demonstrates advantages along with higher revision/readmission rates. Regardless of patient indication, MIS exposes the surgeon to significantly more radiation; it is unclear how this impacts patients. These results should optimize informed decision-making regarding MIS versus open spine surgery, particularly in the current advertising climate greatly favoring MIS.
Somatic and neuritic spines on tyrosine hydroxylase–immunopositive cells of rat retina
Fasoli, Anna; Dang, James; Johnson, Jeffrey S.; Gouw, Aaron H.; Iseppe, Alex Fogli; Ishida, Andrew T.
2018-01-01
Dopamine- and tyrosine hydroxylase–immunopositive cells (TH cells) modulate visually driven signals as they flow through retinal photoreceptor, bipolar, and ganglion cells. Previous studies suggested that TH cells release dopamine from varicose axons arborizing in the inner and outer plexiform layers after glutamatergic synapses depolarize TH cell dendrites in the inner plexiform layer and these depolarizations propagate to the varicosities. Although it has been proposed that these excitatory synapses are formed onto appendages resembling dendritic spines, spines have not been found on TH cells of most species examined to date or on TH cell somata that release dopamine when exposed to glutamate receptor agonists. By use of protocols that preserve proximal retinal neuron morphology, we have examined the shape, distribution, and synapse-related immunoreactivity of adult rat TH cells. We report here that TH cell somata, tapering and varicose inner plexiform layer neurites, and varicose outer plexiform layer neurites all bear spines, that some of these spines are immunopositive for glutamate receptor and postsynaptic density proteins (viz., GluR1, GluR4, NR1, PSD-95, and PSD-93), that TH cell somata and tapering neurites are also immunopositive for a γ-aminobutyric acid (GABA) receptor subunit (GABAARα1), and that a synaptic ribbon-specific protein (RIBEYE) is found adjacent to some colocalizations of GluR1 and TH in the inner plexiform layer. These results identify previously undescribed sites at which glutamatergic and GABAergic inputs may stimulate and inhibit dopamine release, especially at somata and along varicose neurites that emerge from these somata and arborize in various levels of the retina. PMID:28035673
Lamellar and fibre bundle mechanics of the annulus fibrosus in bovine intervertebral disc.
Vergari, Claudio; Mansfield, Jessica; Meakin, Judith R; Winlove, Peter C
2016-06-01
The intervertebral disc is a multicomposite structure, with an outer fibrous ring, the annulus fibrosus, retaining a gel-like core, the nucleus pulposus. The disc presents complex mechanical behaviour, and it is of high importance for spine biomechanics. Advances in multiscale modelling and disc repair raised a need for new quantitative data on the finest details of annulus fibrosus mechanics. In this work we explored inter-lamella and inter-bundle behaviour of the outer annulus using micromechanical testing and second harmonic generation microscopy. Twenty-one intervertebral discs were dissected from cow tails; the nucleus and inner annulus were excised to leave a ring of outer annulus, which was tested in circumferential loading while imaging the tissue's collagen fibres network with sub-micron resolution. Custom software was developed to determine local tissue strains through image analysis. Inter-bundle linear and shear strains were 5.5 and 2.8 times higher than intra-bundle strains. Bundles tended to remain parallel while rotating under loading, with large slipping between them. Inter-lamella linear strain was almost 3 times the intra-lamella one, but no slipping was observed at the junction between lamellae. This study confirms that outer annulus straining is mainly due to bundles slipping and rotating. Further development of disc multiscale modelling and repair techniques should take into account this modular behaviour of the lamella, rather than considering it as a homogeneous fibre-reinforced matrix. The intervertebral disc is an organ tucked between each couple of vertebrae in the spine. It is composed by an outer fibrous layer retaining a gel-like core. This organ undergoes severe and repeated loading during everyday life activities, since it is the compliant component that gives the spine its flexibility. Its properties are affected by pathologies such as disc degeneration, a major cause of back pain. In this article we explored the micromechanical behaviour of the disc's outer layer using second harmonic generation, a technique which allowed us to visualize, with unprecedented detail, how bundles of collagen fibres slide relative to each other when loaded. Our results will help further the development of new multiscale numerical models and repairing techniques. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Vallance, James W.; Schneider, David J.; Schilling, Steve P.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.
2008-01-01
The chief near-surface controls on spine extrusion during 2004-6 have been vent location, relict topographic surfaces from the 1980s, and spine remnants emplaced previously during the present eruption. In contrast, glacier ice has had minimal influence on spine growth. Ice as thick as 150 m has prevented formation of marginal angle-of-repose talus fans but has not provided sufficient resistance to stop spine growth or slow it appreciably. Spines initially emerged along a relict south-facing slope as steep as 40° on the 1980s dome. The open space of the moat between that dome and the crater walls permitted initial southward migration of recumbent spines. An initial spine impinged on the opposing slopes of the crater and stopped; in contrast, recumbent whaleback spines of phase 3 impinged on opposing walls of the crater at oblique angles and rotated eastward before breaking up. Once spine remnants occupied all available open space to the south, spines thrust over previous remnants. Finally, with south and east portions of the moat filled, spine growth proceeded westward. Although Crater Glacier had only a small influence on the growing spines, spine growth affected the glacier dramatically, initially dividing it into two arms and then bulldozing it hundreds of meters, first east and then west, and heaping it more than 100 m higher than its original altitude.
Spine Patterning Is Guided by Segmentation of the Notochord Sheath.
Wopat, Susan; Bagwell, Jennifer; Sumigray, Kaelyn D; Dickson, Amy L; Huitema, Leonie F A; Poss, Kenneth D; Schulte-Merker, Stefan; Bagnat, Michel
2018-02-20
The spine is a segmented axial structure made of alternating vertebral bodies (centra) and intervertebral discs (IVDs) assembled around the notochord. Here, we show that, prior to centra formation, the outer epithelial cell layer of the zebrafish notochord, the sheath, segments into alternating domains corresponding to the prospective centra and IVD areas. This process occurs sequentially in an anteroposterior direction via the activation of Notch signaling in alternating segments of the sheath, which transition from cartilaginous to mineralizing domains. Subsequently, osteoblasts are recruited to the mineralized domains of the notochord sheath to form mature centra. Tissue-specific manipulation of Notch signaling in sheath cells produces notochord segmentation defects that are mirrored in the spine. Together, our findings demonstrate that notochord sheath segmentation provides a template for vertebral patterning in the zebrafish spine. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.
Geometrical properties of the human child cervical spine with a focus on the C1 vertebra.
Yoganandan, Narayan; Pintar, Frank A; Lew, Sean M; Rao, Raj D
2014-01-01
Child dummies and injury criteria used in automotive crashworthiness environments are based on scaling from the adult and/or between children of different ages. Cartilage-to-bone ossification, spinal canal and joint developments of the spine, and strength attainments do not grow linearly from birth to maturity. Though this is known to medical professionals, age-based quantitative analyses are needed to accurately model the pediatric spine. The objective of this study was to quantify longitudinal growths of various regions of the first cervical vertebrae, responsible for transmitting the axial load from the base of the skull through the condyles to the neck/torso. Computed tomography (CT) images of 54 children from one day to 18 years of age were retrospectively used to determine the following geometrical properties: bilateral neurocentral synchondroses widths, the width of posterior synchondrosis, outer and inner anteroposterior and transverse diameters, spinal canal area, and depths of the anterior and posterior arches of the C1 vertebra. Both axial and sagittal CT images were used in the analysis. Sagittal images were used to quantify data for the anterior and posterior arches and axial images were used for all described cross-sectional parameters. Geometrical properties were extracted and reported for the various parameters at 6 months; one year; 18 months; and 3, 6, and 10 years of age corresponding to the dummy family ages routinely used in motor vehicle crashworthiness research and other applications. The outer transverse diameter ranged from 4.97 to 7.08 cm; outer and inner antero-posterior diameters ranged from 2.99 to 4.18 and 2.19 to 3.03 mm; and spinal canal area ranged from 4.34 to 6.68 mm(2). Other data are given in the body of the article. The growths of the first cervical vertebra quantified in terms of the above variables occurred nonlinearly with age and the degree of nonlinearity depended on the type of the geometrical parameter. Growths did not match with the simple scaling ratios based on the adult spine, used in different studies reported in the current literature. These early nonlinear and nonuniform age- and local geometry-specific variations should be considered in human finite element models for an accurate transfer of the external load from the atlas to the subaxial spine and to improve their fidelity and biomechanical capabilities.
Ellis, Kathryn; Hoffman, Brenton D.; Bagnat, Michel
2013-01-01
The notochord is an evolutionarily conserved structure that has long been known to play an important role in patterning during embryogenesis. Structurally, the notochord is composed of two cell layers: an outer epithelial-like sheath, and an inner core of cells that contain large fluid-filled vacuoles. We have recently shown these notochord vacuoles are lysosome-related organelles that form through Rab32a and vacuolar-type proton-ATPase-dependent acidification. Disruption of notochord vacuoles results in a shortened embryo along the anterior-posterior axis. Interestingly, we discovered that notochord vacuoles are also essential for proper spine morphogenesis and that vacuole defects lead to scoliosis of the spine. Here we discuss the cellular organization of the notochord and how key features of its architecture allow the notochord to function in embryonic axis elongation and spine formation. PMID:23887209
Shifts in coastal fish communities: Is eutrophication always beneficial for sticklebacks?
NASA Astrophysics Data System (ADS)
Gagnon, Karine; Gräfnings, Max; Boström, Christoffer
2017-11-01
Following declines of predatory fish, mesopredators such as sticklebacks have been linked to shifts in coastal trophic networks through both top-down (preying on mesograzers and facilitating algal blooms) and bottom-up (benefitting from eutrophicated conditions) processes. Here, we tested whether the association between eutrophication effects (filamentous algae and turbidity) and sticklebacks held true in the Finnish Archipelago Sea where predatory fish populations have remained stable. If so, sticklebacks should be more abundant in the middle archipelago, where eutrophic conditions have led to increased turbidity, higher filamentous algal loads, and decreased cover of submerged aquatic vegetation (SAV), than in the outer archipelago, where environmental conditions are better. We measured the spatial and seasonal variation of sticklebacks (three-spined Gasterosteus aculeatus and nine-spined Pungitius pungitius) in middle and outer archipelago sites, as well as environmental variables potentially affecting their abundance. Adults and juveniles of both species were more abundant in the outer than middle archipelago. The outer archipelago was characterized by greater Secchi depth throughout the summer and higher SAV cover in late summer. Secchi depth was positively correlated with stickleback abundance of both species, while SAV cover was also positively correlated in late summer. Filamentous algal cover was high in both the middle and outer archipelago, but not consistently associated with stickleback abundance throughout the summer. While sticklebacks have been thought to both contribute to, and benefit from, eutrophication, our results instead suggest that the resulting environmental changes may have adverse effects on sticklebacks, especially if predators are present. This may lead them to shift their breeding grounds and spatial distribution to less eutrophicated areas where lower turbidity and the resulting increased availability of SAV provide refuge from predators for juveniles, and higher quality breeding and feeding grounds for adults.
... of another Abnormal curvatures, such as those from scoliosis or kyphosis Arthritis in the spine, such as ... Spine surgery - discharge Surgical wound care - open Images Scoliosis Spinal fusion - series References Bennett EE, Hwang L, ...
Coexistence of Extraskeletal Mesenchymal Chondrosarcoma and Isolated Hemihyperplasia: A Case Report
Demirkiran, Nihat Demirhan; Akdeniz, Olcay; Hapa, Onur; Havıtçıoğlu, Hasan
2016-01-01
Introduction: Arthroscopic fixation of tibial spine fracture without damage to the growth plate is very important in patients with open physis. The present article describes a simple and effective technique being used for the first time to treat this condition. Case report: A 16-year-old boy sustained avulsion fractures of tibial spine while playing. He was treated arthroscopically with excellent result. Conclusion: Arthroscopic fixation of tibial spine fracture in patients with open physis with two cannulated screws perpendicular to each other is a very simple technique which provides strong construct, and allows early mobilization without risk of damage to the growth plate. PMID:27703933
Attachment device for an inflatable protective cushion
Nelsen, J.M.; Luna, D.A.; Gwinn, K.W.
1997-11-18
An inflatable cushion assembly for use with an inflator comprises an inflatable cushion having an inner surface, outer surface, and at least one protrusion extending from one of the inner or outer surfaces. The inflatable cushion defines an opening between the inner surface and the outer surface for receiving the inflator. An attachment member contacts the one of the inner or outer surfaces adjacent the opening and includes a groove for receiving the protrusion, the attachment member securing the inflator within the opening. 22 figs.
Attachment device for an inflatable protective cushion
Nelsen, J.M.; Luna, D.A.; Gwinn, K.W.
1998-12-08
An inflatable cushion assembly for use with an inflator comprises an inflatable cushion having an inner surface, outer surface, and at least one protrusion extending from one of the inner or outer surfaces. The inflatable cushion defines an opening between the inner surface and the outer surface for receiving the inflator. An attachment member contacts the one of the inner or outer surfaces adjacent the opening and includes a groove for receiving the protrusion, the attachment member securing the inflator within the opening. 22 figs.
Avoidance of Wrong-level Thoracic Spine Surgery Using Sterile Spinal Needles: A Technical Report.
Chin, Kingsley R; Seale, Jason; Cumming, Vanessa
2017-02-01
A technical report. The aim of the present study was to present an improvement on localization techniques employed for use in the thoracic spine using sterile spinal needles docked on the transverse process of each vertebra, which can be performed in both percutaneous and open spinal procedures. Wrong-level surgery may have momentous clinical and emotional implications for a patient and surgeon. It is reported that one in every 2 spine surgeons will operate on the wrong level during his or her career. Correctly localizing the specific thoracic level remains a significant challenge during spine surgery. Fluoroscopic anteroposterior and lateral views were obtained starting in the lower lumbar spine, and an 18-G spinal needle was placed in the transverse process of L3 counting up from the sacrum and also at T12. The fluoroscopy was then moved cephalad and counting from the spinal needle at T12, the other spinal needles were placed at the targeted operating thoracic vertebrae. Once this was done, we were able to accurately determine the thoracic levels for surgical intervention. Using this technique, the markers were kept in place even after the incisions were made. This prevented us from losing our location in the thoracic spine. Correctly placed instrumentation was made evident with postoperative imaging. We have described the successful use of a new technique using spinal needles docked against transverse processes to correctly and reliably identify thoracic levels before instrumentation. The technique was reproducible in both open surgeries and for a percutaneous procedure. This technique maintains the correct spinal level during an open procedure. We posit that wrong-level thoracic spine surgery may be preventable.
Kreinest, Michael; Rillig, Jan; Grützner, Paul A; Küffer, Maike; Tinelli, Marco; Matschke, Stefan
2017-05-01
The aim of the current study is to analyze perioperative data and complications of open vs. percutaneous dorsal instrumentation after dorsal stabilization in patients suffering from fractures of the thoracic or lumbar spine. In the time period from 01/2007 to 06/2009, open surgical approach was used for dorsal stabilization. The percutaneous surgical approach was used from 05/2009 to 03/2014. In every time period, all types of fractures were treated only by open or by percutaneous approach, respectively, to avoid any selection bias. Retrospectively, epidemiological data, complications and perioperative data were documented and statistically analyzed. A total of 491 patients met the inclusion criteria. Open surgery procedure was carried out on 169 patients, and percutaneous surgery procedure was carried out on 322 patients. Fracture level ranged from T1 to L5, and fractures were classified types A, B, and C. In 91.4% of all patients, no complication occured following dorsal stabilization after traumatic spine fracture during their hospital stay. However, 42 complications related to dorsal stabilization have been documented during the hospital stay. The complication rate was 14.8% if open surgical approach has been used and was significantly reduced to 5.3% using percutaneous surgical approach. Post-operative hospital stay was also reduced significantly using the percutaneous surgical approach. According to the current study, percutaneous dorsal stabilization of the spine could also be safely used in trauma cases and is not restricted to degenerative spinal surgery.
2017-01-01
The cystacanths of Neoandracantha peruensis n. gen. n. sp. are described from the ghost crab Ocypode gaudichaudii collected from the Pacific coast of Peru. While it is uncommon to describe acanthocephalan taxa from immature stages, the presence of clear-cut distinguishing features separating the present material from its nearest congeneric taxa, and the absence of adults, justifies the erection N. peruensis. The new genus is distinguished by having three separate fields of trunk spines. Specimens of N. peruensis have a slender trunk with two anterior swellings, 3 separate fields of spines on the foretrunk swelling, and no genital spines on the hindtrunk. The proboscis of the new species is heavily armored with 21–22 longitudinal rows of 22 hooks each. Hook no. 14 is more robust ventrally than dorsally. Cystacanths of N. peruensis also have a long tubular hindtrunk and the males have diagonal testes in the midtrunk swelling. Specimens of the closely related Andracantha Schmidt, 1975 have anteriorly enlarged pear-shaped Corynosoma-like trunks, only two fields of anterior trunk spines with occasional genital spines, and bilateral or tandem testes. Proboscides of species of Andracantha have considerably fewer hooks that gradually decrease in size posteriorly. The taxonomic component of this work is amplified by metal analysis of hooks and spines that shows a marked amount of magnesium (Mg) in hooks but not in spines. The highest level of sulfur (S) was found in the outer layer of hooks and anterior spines. The metal footprint of hooks and spines varies in different species of acanthocephalans and has an interspecific diagnostic value. PMID:29072573
Turbine nozzle/nozzle support structure
Boyd, Gary L.; Shaffer, James E.
1997-01-01
An axial flow turbine's nozzle/nozzle support structure having a cantilevered nozzle outer structure including an outer shroud and airfoil vanes extending radially inwardly therefrom, an inner shroud radially adjacent the inner end of the airfoil vanes and cooperatively disposed relative to the outer shroud to provide an annular fluid flow path, an inner and an outer support ring respectively arranged radially inside the inner shroud and axially adjacent a portion of the outer shroud, and pins extending through such portion and into the outer support ring. The inner support ring or inner shroud has a groove therein bounded by end walls for receiving and being axially abuttable with a locating projection from the adjacent airfoil vane, inner shroud, or inner support ring. The nozzle outer structure may comprise segments each of which has a single protrusion which is axially engageable with the outer support ring or, alternatively, a first and second protrusion which are arcuately and axially separated and which include axial openings therein whereby first and second protrusions on respective, arcuately adjacent nozzle segments have axial openings therein which are alignable with connector openings in the outer support ring and within each of such aligned openings a pin is receivable. The inner shroud may, likewise, comprise segments which, when assembled in operating configuration, have a 360 degree expanse.
Turbine nozzle/nozzle support structure
Boyd, G.L.; Shaffer, J.E.
1997-01-07
An axial flow turbine`s nozzle/nozzle support structure is described having a cantilevered nozzle outer structure including an outer shroud and airfoil vanes extending radially inwardly therefrom, an inner shroud radially adjacent the inner end of the airfoil vanes and cooperatively disposed relative to the outer shroud to provide an annular fluid flow path, an inner and an outer support ring respectively arranged radially inside the inner shroud and axially adjacent a portion of the outer shroud, and pins extending through such portion and into the outer support ring. The inner support ring or inner shroud has a groove therein bounded by end walls for receiving and being axially abuttable with a locating projection from the adjacent airfoil vane, inner shroud, or inner support ring. The nozzle outer structure may comprise segments each of which has a single protrusion which is axially engageable with the outer support ring or, alternatively, a first and second protrusion which are arcuately and axially separated and which include axial openings therein whereby first and second protrusions on respective, arcuately adjacent nozzle segments have axial openings therein which are alignable with connector openings in the outer support ring and within each of such aligned openings a pin is receivable. The inner shroud may, likewise, comprise segments which, when assembled in operating configuration, have a 360 degree expanse. 6 figs.
Turbine nozzle/nozzle support structure
Boyd, Gary L.; Shaffer, James E.
1996-01-01
An axial flow turbine's nozzle/nozzle support structure having a cantilevered nozzle outer structure including an outer shroud and airfoil vanes extending radially inwardly therefrom, an inner shroud radially adjacent the inner end of the airfoil vanes and cooperatively disposed relative to the outer shroud to provide an annular fluid flow path, an inner and an outer support ring respectively arranged radially inside the inner shroud and axially adjacent a portion of the outer shroud, and pins extending through such portion and into the outer support ring. The inner support ring or inner shroud has a groove therein bounded by end walls for receiving and being axially abuttable with a locating projection from the adjacent airfoil vane, inner shroud, or inner support ring. The nozzle outer structure may comprise segments each of which has a single protrusion which is axially engageable with the outer support ring or, alternatively, a first and second protrusion which are arcuately and axially separated and which include axial openings therein whereby first and second protrusions on respective, arcuately adjacent nozzle segments have axial openings therein which are alignable with connector openings in the outer support ring and within each of such aligned openings a pin is receivable. The inner shroud may, likewise, comprise segments which, when assembled in operating configuration, have a 360 degree expanse.
Turbine nozzle/nozzle support structure
Boyd, G.L.; Shaffer, J.E.
1996-09-10
An axial flow turbine`s nozzle/nozzle support structure is described having a cantilevered nozzle outer structure including an outer shroud and airfoil vanes extending radially inwardly therefrom, an inner shroud radially adjacent the inner end of the airfoil vanes and cooperatively disposed relative to the outer shroud to provide an annular fluid flow path, an inner and an outer support ring respectively arranged radially inside the inner shroud and axially adjacent a portion of the outer shroud, and pins extending through such portion and into the outer support ring. The inner support ring or inner shroud has a groove therein bounded by end walls for receiving and being axially abuttable with a locating projection from the adjacent airfoil vane, inner shroud, or inner support ring. The nozzle outer structure may comprise segments each of which has a single protrusion which is axially engageable with the outer support ring or, alternatively, a first and second protrusion which are arcuately and axially separated and which include axial openings therein whereby first and second protrusions on respective, arcuately adjacent nozzle segments have axial openings therein which are alignable with connector openings in the outer support ring and within each of such aligned openings a pin is receivable. The inner shroud may, likewise, comprise segments which, when assembled in operating configuration, have a 360 degree expanse. 6 figs.
Turbine nozzle/nozzle support structure
Boyd, Gary L.; Shaffer, James E.
1995-01-01
An axial flow turbine's nozzle/nozzle support structure having a cantilevered nozzle outer structure including an outer shroud and airfoil vanes extending radially inwardly therefrom, an inner shroud radially adjacent the inner end of the airfoil vanes and cooperatively disposed relative to the outer shroud to provide an annular fluid flow path, an inner and an outer support ring respectively arranged radially inside the inner shroud and axially adjacent a portion of the outer shroud, and pins extending through such portion and into the outer support ring. The inner support ring or inner shroud has a groove therein bounded by end walls for receiving and being axially abuttable with a locating projection from the adjacent airfoil vane, inner shroud, or inner support ring. The nozzle outer structure may comprise segments each of which has a single protrusion which is axially engageable with the outer support ring or, alternatively, a first and second protrusion which are arcuately and axially separated and which include axial openings therein whereby first and second protrusions on respective, arcuately adjacent nozzle segments have axial openings therein which are alignable with connector openings in the outer support ring and within each of such aligned openings a pin is receivable. The inner shroud may, likewise, comprise segments which, when assembled in operating configuration, have a 360 degree expanse.
Turbine nozzle/nozzle support structure
Boyd, G.L.; Shaffer, J.E.
1995-08-15
An axial flow turbine`s nozzle/nozzle support structure is described having a cantilevered nozzle outer structure including an outer shroud and airfoil vanes extending radially inwardly therefrom, an inner shroud radially adjacent the inner end of the airfoil vanes and cooperatively disposed relative to the outer shroud to provide an annular fluid flow path, an inner and an outer support ring respectively arranged radially inside the inner shroud and axially adjacent a portion of the outer shroud, and pins extending through such portion and into the outer support ring. The inner support ring or inner shroud has a groove therein bounded by end walls for receiving and being axially abuttable with a locating projection from the adjacent airfoil vane, inner shroud, or inner support ring. The nozzle outer structure may comprise segments each of which has a single protrusion which is axially engageable with the outer support ring or, alternatively, a first and second protrusion which are arcuately and axially separated and which include axial openings therein whereby first and second protrusions on respective, arcuately adjacent nozzle segments have axial openings therein which are alignable with connector openings in the outer support ring and within each of such aligned openings a pin is receivable. The inner shroud may, likewise, comprise segments which, when assembled in operating configuration, have a 360 degree expanse. 6 figs.
Is minimal access spine surgery more cost-effective than conventional spine surgery?
Lubelski, Daniel; Mihalovich, Kathryn E; Skelly, Andrea C; Fehlings, Michael G; Harrop, James S; Mummaneni, Praveen V; Wang, Michael Y; Steinmetz, Michael P
2014-10-15
Systematic review. To summarize and critically review the economic literature evaluating the cost-effectiveness of minimal access surgery (MAS) compared with conventional open procedures for the cervical and lumbar spine. MAS techniques may improve perioperative parameters (length of hospital stay and extent of blood loss) compared with conventional open approaches. However, some have questioned the clinical efficacy of these differences and the associated cost-effectiveness implications. When considering the long-term outcomes, there seem to be no significant differences between MAS and open surgery. PubMed, EMBASE, the Cochrane Collaboration database, University of York, Centre for Reviews and Dissemination (NHS-EED and HTA), and the Tufts CEA Registry were reviewed to identify full economic studies comparing MAS with open techniques prior to December 24, 2013, based on the key questions established a priori. Only economic studies that evaluated and synthesized the costs and consequences of MAS compared with conventional open procedures (i.e., cost-minimization, cost-benefit, cost-effectiveness, or cost-utility) were considered for inclusion. Full text of the articles meeting inclusion criteria were reviewed by 2 independent investigators to obtain the final collection of included studies. The Quality of Health Economic Studies instrument was scored by 2 independent reviewers to provide an initial basis for critical appraisal of included economic studies. The search strategy yielded 198 potentially relevant citations, and 6 studies met the inclusion criteria, evaluating the costs and consequences of MAS versus conventional open procedures performed for the lumbar spine; no studies for the cervical spine met the inclusion criteria. Studies compared MAS tubular discectomy with conventional microdiscectomy, minimal access transforaminal lumbar interbody fusion versus open transforaminal lumbar interbody fusion, and multilevel hemilaminectomy via MAS versus open approach. Overall, the included cost-effectiveness studies generally supported no significant differences between open surgery and MAS lumbar approaches. However, these conclusions are preliminary because there was a paucity of high-quality evidence. Much of the evidence lacked details on methodology for modeling, related assumptions, justification of economic model chosen, and sources and types of included costs and consequences. The follow-up periods were highly variable, indirect costs were not frequently analyzed or reported, and many of the studies were conducted by a single group, thereby limiting generalizability. Prospective studies are needed to define differences and optimal treatment algorithms. 3.
Apparatus for premixing in a gas turbine engine
McCormick, Keith Alan; Smith, Duane A.
2002-01-01
An apparatus for mixing fuel with oxidizing agent is disclosed comprising an outer body and an inner body. The outer body has an interior surface extending between an inlet end toward an outlet end. The interior surface includes a first plurality of openings. The inner body has an exterior surface extending between the first end and the second end of the inner body. The exterior surface of the inner body includes a second plurality of openings. At least a portion of the exterior surface of the inner body is positioned within the outer body to define a mixing channel between the exterior surface of the inner body and the interior surface of the outer body. In one form the first and second plurality of openings substantially longitudinally span at least one of the outer body and the inner body. In another form the first and second plurality of openings are substantially radially oriented. In yet another form the first and second plurality of openings are offset from one another.
Weiner, Joseph A; Cook, Ralph W; Hashmi, Sohaib; Schallmo, Michael S; Chun, Danielle S; Barth, Kathryn A; Singh, Sameer K; Patel, Alpesh A; Hsu, Wellington K
2017-09-15
A retrospective review of Centers for Medicare and Medicaid Services Database. Utilizing Open Payments data, we aimed to determine the prevalence of industry payments to orthopedic and neurospine surgeons, report the magnitude of those relationships, and help outline the surgeon demographic factors associated with industry relationships. Previous Open Payments data revealed that orthopedic surgeons receive the highest value of industry payments. No study has investigated the financial relationship between spine surgeons and industry using the most recent release of Open Payments data. A database of 5898 spine surgeons in the United States was derived from the Open Payments website. Demographic data were collected, including the type of residency training, years of experience, practice setting, type of medical degree, place of training, gender, and region of practice. Multivariate generalized linear mixed models were utilized to determine the relationship between demographics and industry payments. A total of 5898 spine surgeons met inclusion criteria. About 91.6% of surgeons reported at least one financial relationship with industry. The median total value of payments was $994.07. Surgeons receiving over $1,000,000 from industry during the reporting period represented 6.6% of the database and accounted for 83.5% of the total value exchanged. Orthopedic training (P < 0.001), academic practice setting (P < 0.0001), male gender (P < 0.0001), and West or South region of practice (P < 0.0001) were associated with industry payments. Linear regression analysis revealed a strong inverse relationship between years of experience and number of payments from industry (r = -0.967, P < 0.0001). Financial relationships between spine surgeons and industry are highly prevalent. Surgeon demographics have a significant association with industry-surgeon financial relationships. Our reported value of payments did not include ownership or research payments and thus likely underestimates the magnitude of these financial relationships. 3.
Modeling Reconnection-Driven Solar Polar Jets with Gravity and Wind
NASA Astrophysics Data System (ADS)
Karpen, Judith T.; DeVore, C. R.; Antiochos, S. K.
2013-07-01
Solar polar jets are dynamic, narrow, radially extended structures observed in EUV emission. They have been found to originate within the open magnetic field of coronal holes in “anemone” regions, which are generally accepted to be intrusions of opposite polarity. The associated embedded-dipole topology consists of a spine line emanating from a null point atop a dome-shaped fan surface. Previous work (Pariat et al. 2009, 2010) has validated the idea that magnetic free energy stored on twisted closed field lines within the fan surface can be released explosively by the onset of fast reconnection between the highly stressed closed field inside the null and the unstressed open field outside (Antiochos 1996). The simulations showed that a dense jet comprising a nonlinear, torsional Alfven wave is ejected into the outer corona on the newly reconnected open field lines. While proving the principle of the basic model, those simulations neglected the important effects of gravity, the solar wind, and an expanding spherical geometry. We introduce those additional physical processes in new simulations of reconnection-driven jets, to determine whether the model remains robust in the resulting more realistic setting, and to begin establishing the signatures of the jets in the inner heliosphere for comparison with observations. Initial results demonstrate explosive energy release and a jet in the low corona very much like that in the earlier Cartesian, gravity-free, static-atmosphere runs. We report our analysis of the results, their comparison with previous work, and their implications for observations. This work was supported by NASA’s LWS TR&T program.Abstract (2,250 Maximum Characters): Solar polar jets are dynamic, narrow, radially extended structures observed in EUV emission. They have been found to originate within the open magnetic field of coronal holes in “anemone” regions, which are generally accepted to be intrusions of opposite polarity. The associated embedded-dipole topology consists of a spine line emanating from a null point atop a dome-shaped fan surface. Previous work (Pariat et al. 2009, 2010) has validated the idea that magnetic free energy stored on twisted closed field lines within the fan surface can be released explosively by the onset of fast reconnection between the highly stressed closed field inside the null and the unstressed open field outside (Antiochos 1996). The simulations showed that a dense jet comprising a nonlinear, torsional Alfven wave is ejected into the outer corona on the newly reconnected open field lines. While proving the principle of the basic model, those simulations neglected the important effects of gravity, the solar wind, and an expanding spherical geometry. We introduce those additional physical processes in new simulations of reconnection-driven jets, to determine whether the model remains robust in the resulting more realistic setting, and to begin establishing the signatures of the jets in the inner heliosphere for comparison with observations. Initial results demonstrate explosive energy release and a jet in the low corona very much like that in the earlier Cartesian, gravity-free, static-atmosphere runs. We report our analysis of the results, their comparison with previous work, and their implications for observations. This work was supported by NASA’s LWS TR&T program.
A musculoskeletal model for the lumbar spine.
Christophy, Miguel; Faruk Senan, Nur Adila; Lotz, Jeffrey C; O'Reilly, Oliver M
2012-01-01
A new musculoskeletal model for the lumbar spine is described in this paper. This model features a rigid pelvis and sacrum, the five lumbar vertebrae, and a rigid torso consisting of a lumped thoracic spine and ribcage. The motion of the individual lumbar vertebrae was defined as a fraction of the net lumbar movement about the three rotational degrees of freedom: flexion-extension lateral bending, and axial rotation. Additionally, the eight main muscle groups of the lumbar spine were incorporated using 238 muscle fascicles with prescriptions for the parameters in the Hill-type muscle models obtained with the help of an extensive literature survey. The features of the model include the abilities to predict joint reactions, muscle forces, and muscle activation patterns. To illustrate the capabilities of the model and validate its physiological similarity, the model's predictions for the moment arms of the muscles are shown for a range of flexion-extension motions of the lower back. The model uses the OpenSim platform and is freely available on https://www.simtk.org/home/lumbarspine to other spinal researchers interested in analyzing the kinematics of the spine. The model can also be integrated with existing OpenSim models to build more comprehensive models of the human body.
Smith, Lachlan J; Martin, John T; Szczesny, Spencer E; Ponder, Katherine P; Haskins, Mark E; Elliott, Dawn M
2010-01-01
Mucopolysaccharidosis VII (MPS VII) is a lysosomal storage disorder characterized by a deficiency in β-glucuronidase activity, leading to systemic accumulation of poorly degraded glycosaminoglycans (GAG). Along with other morbidities, MPS VII is associated with paediatric spinal deformity. The objective of this study was to examine potential associations between abnormal lumbar spine matrix structure and composition in MPS VII, and spine segment and tissue-level mechanical properties, using a naturally occurring canine model with a similar clinical phenotype to the human form of the disorder. Segments from juvenile MPS VII and unaffected dogs were allocated to: radiography, gross morphology, histology, biochemistry, and mechanical testing. MPS VII spines had radiolucent lesions in the vertebral body epiphyses. Histologically, this corresponded to a GAG-rich cartilaginous region in place of bone, and elevated GAG staining was seen in the annulus fibrosus. Biochemically, MPS VII samples had elevated GAG in the outer annulus fibrosus and epiphyses, low calcium in the epiphyses, and high water content in all regions except the nucleus pulposus. MPS VII spine segments had higher range of motion and lower stiffness than controls. Endplate indentation stiffness and failure loads were significantly lower in MPS VII samples, while annulus fibrosus tensile mechanical properties were normal. Vertebral body lesions in MPS VII spines suggest a failure to convert cartilage to bone during development. Low stiffness in these regions likely contributes to mechanical weakness in motion segments and is a potential factor in the progression of spinal deformity. PMID:19918911
Two new fish species of the subfamily Anthiinae (Perciformes, Serranidae) from the Marquesas.
Williams, Jeffrey T; Delrieu-Trottin, Erwan; Planes, Serge
2013-01-01
Two new species of anthiine fishes are described from the Marquesas Islands, French Polynesia. Plectranthias flammeus was found at depths from 20-45 m and is characterized by dorsal rays X, 14 or 15, with spines 1-6 bearing fleshy white tabs at their tips, longest fleshy tab on spine 4; 14 unbranched pectoral rays; lateral line incomplete with 16-17 tubed scales; preopercle with 8-10 small spines along posterior margin and 2 antrorse spines on ventral margin; broad, fiery red-orange streak across lower cheek; head and body with irregularly spaced maroon-ringed yellow blotches on a white background; pair of small dark oblong spots (red with black centers in life) on the bases of the middle rays of the caudal fin. Pseudanthias oumati was found on the outer reef slope of Fatu Hiva at a depth of 50-55 m and is characterized by 3rd dorsal spine elongate and tipped with fleshy yellow filament extending beyond tip of spine; lateral-line scales 43; gill rakers 10 + 28; no papillae on posterior edge of orbit; front of upper lip not thickened (male condition unknown); caudal fin lunate; color of female yellow, all fins yellow with narrow magenta margin (except pectoral fin, which lacks magenta); no stripe from snout to pectoral base; small scales located on basal quarter of soft-dorsal fin from segmented rays 1-12; dorsal profile of head slightly concave.
Raabe, Margaret E.; Chaudhari, Ajit M.W.
2016-01-01
The ability of a biomechanical simulation to produce results that can translate to real-life situations is largely dependent on the physiological accuracy of the musculoskeletal model. There are a limited number of freely-available, full-body models that exist in OpenSim, and those that do exist are very limited in terms of trunk musculature and degrees of freedom in the spine. Properly modeling the motion and musculature of the trunk is necessary to most accurately estimate lower extremity and spinal loading. The objective of this study was to develop and validate a more physiologically accurate OpenSim full-body model. By building upon three previously developed OpenSim models, the Full-Body Lumbar Spine (FBLS) model, comprised of 21 segments, 30 degrees-of-freedom, and 324 musculotendon actuators, was developed. The five lumbar vertebrae were modeled as individual bodies, and coupled constraints were implemented to describe the net motion of the spine. The eight major muscle groups of the lumbar spine were modeled (rectus abdominis, external and internal obliques, erector spinae, multifidus, quadratus lumborum, psoas major, and latissimus dorsi), and many of these muscle groups were modeled as multiple fascicles allowing the large muscles to act in multiple directions. The resulting FBLS model's trunk muscle geometry, maximal isometric joint moments, and simulated muscle activations compare well to experimental data. The FBLS model will be made freely available (https://simtk.org/home/fullbodylumbar) for others to perform additional analyses and develop simulations investigating full-body dynamics and contributions of the trunk muscles to dynamic tasks. PMID:26947033
Levron, Céline; Poddubnaya, Larisa G; Kuchta, Roman; Freeman, Mark; Wang, Yan-Hai; Scholz, Tomás
2008-08-01
For the first time, the ultrastructure of the armed cirrus of an echinophallid cestode, Paraechinophallus japonicus (Yamaguti, 1934), has been studied with the use of scanning and transmission electron microscopy. Two sets of eversible copulatory organs (approximately 300 microm in length and approximately 130 microm in width) are present on the dorsal side of each segment near the lateral margin of the strobila. Except for the terminal portion, the cirrus is covered with large spines (up to 40 mircom long, measured from SEM photomicrographs) composed of 2 parts. The basal portion contains a lobed electron-dense outer region that gives way to a reticular meshwork of electron-dense material. The apical region of the spines, composed of a homogeneous, moderately electron-dense matrix, is slightly curved distally. Spines are covered with a cortical zone. Between the spines, the distal cytoplasm is covered with microvilli of about 1.2 microm in length. The wall of the cirrus sac, which is approximately 500 microm long and approximately 250 microm wide, is composed of 2 layers of muscles, i.e., an internal layer of circular muscles and external longitudinal muscles. Microvilli on the cirrus of P. japonicus are reported for the first time in the Cestoda, whereas the spines on the cirrus may represent a synapomorphy of bothriocephalidean cestodes of the Echinophallidae.
30 CFR 291.1 - What is MMS's authority to collect information?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER... been denied open and nondiscriminatory access to Outer Continental Shelf (OCS) pipelines as sections of...
Electromyographic monitoring and its anatomical implications in minimally invasive spine surgery.
Uribe, Juan S; Vale, Fernando L; Dakwar, Elias
2010-12-15
Literature review. The objective of this article is to examine current intraoperative electromyography (EMG) neurophysiologic monitoring methods and their application in minimally invasive techniques. We will also discuss the recent application of EMG and its anatomic implications to the minimally invasive lateral transpsoas approach to the spine. Minimally invasive techniques require that the same goals of surgery be achieved, with the hope of decreased morbidity to the patient. Unlike standard open procedures, direct visualization of the anatomy is decreased. To increase the safety of minimally invasive spine surgery, neurophysiological monitoring techniques have been developed. Review of the literature was performed using the National Center for Biotechnology Information databases using PUBMED/MEDLINE. All articles in the English language discussing the use of intraoperative EMG monitoring and minimally invasive spine surgery were reviewed. The role of EMG monitoring in special reference to the minimally invasive lateral transpsoas approach is also described. In total, 76 articles were identified that discussed the role of neuromonitoring in spine surgery. The majority of articles on EMG and spine surgery discuss the use of intraoperative neurophysiological monitoring (IOM) for safe and accurate pedicle screw placement. In general, there is a paucity of literature that pertains to intraoperative EMG neuromonitoring and minimally invasive spine surgery. Recently, EMG has been used during minimally invasive lateral transpsoas approach to the lumbar spine for interbody fusion. The addition of EMG to the lateral approach has contributed to decrease the complication rate from 30% to less than 1%. In minimally invasive approaches to the spine, the use of EMG IOM might provide additional safety, such as percutaneous pedicle screw placement, where visualization is limited compared with conventional open procedures. In addition to knowledge of the anatomy and image guidance, directional EMG IOM is crucial for safe passage through the psoas muscle during the minimally invasive lateral retroperitoneal approach.
Ipsilateral Closed Clavicle and Scapular spine Fracture with Acromioclavicular Joint Disruption.
Kembhavi, Raghavendra S; James, Boblee
2015-01-01
Injuries around shoulder and clavicle are quite common. Injuries involving lateral end of clavicle involving acromioclavicular joints are commoner injuries. In this rare injury, we report about a case involving clavicle and scapular spine fracture with acromioclavicular disruption which has never been described in English literature as per our knowledge. A patient with closed clavicle and scapular spine fracture with acromioclavicular joint disruption was treated with open reduction and internal fixation of clavicle and scapular spine as a staged procedures. Six months post operatively, patient had excellent functional recovery with near full range of movements. Though rare complex injury, clavicle fracture with scapular spine fracture with acromioclavicular disruption, when managed properly with good physiotherapy protocol post operatively will result in good clinical and functional outcome.
Echidna Mark II: one giant leap for 'tilting spine' fibre positioning technology
NASA Astrophysics Data System (ADS)
Gilbert, James; Dalton, Gavin
2016-07-01
The Australian Astronomical Observatory's 'tilting spine' fibre positioning technology has been redeveloped to provide superior performance in a smaller package. The new design offers demonstrated closed-loop positioning errors of <2.8 μm RMS in only five moves ( 10 s excluding metrology overheads) and an improved capacity for open-loop tracking during observations. Tilt-induced throughput losses have been halved by lengthening spines while maintaining excellent accuracy. New low-voltage multilayer piezo actuator technology has reduced a spine's peak drive amplitude from 150V to <10V, simplifying the control electronics design, reducing the system's overall size, and improving modularity. Every spine is now a truly independent unit with a dedicated drive circuit and no restrictions on the timing or direction of fibre motion.
NASA Technical Reports Server (NTRS)
Charles, J. F.; Theakston, H. A. (Inventor)
1980-01-01
A floating nut retention system includes a nut with a central aperture. An inner retainer plate has an opening which is fixedly aligned with the nut aperture. An outer retainer member is formed of a base plate having an opening and a surface adjacent to a surface of the inner retainer plate. The outer retainer member includes a securing mechanism for retaining the inner retainer plate adjacent to the outer retainer member. The securing mechanism enables the inner retainer plate to float with respect to the outer retainer number, while simultaneously forming a bearing surface for inner retainer plate.
Large thermal protection system panel
NASA Technical Reports Server (NTRS)
Weinberg, David J. (Inventor); Myers, Franklin K. (Inventor); Tran, Tu T. (Inventor)
2003-01-01
A protective panel for a reusable launch vehicle provides enhanced moisture protection, simplified maintenance, and increased temperature resistance. The protective panel includes an outer ceramic matrix composite (CMC) panel, and an insulative bag assembly coupled to the outer CMC panel for isolating the launch vehicle from elevated temperatures and moisture. A standoff attachment system attaches the outer CMC panel and the bag assembly to the primary structure of the launch vehicle. The insulative bag assembly includes a foil bag having a first opening shrink fitted to the outer CMC panel such that the first opening and the outer CMC panel form a water tight seal at temperatures below a desired temperature threshold. Fibrous insulation is contained within the foil bag for protecting the launch vehicle from elevated temperatures. The insulative bag assembly further includes a back panel coupled to a second opening of the foil bag such that the fibrous insulation is encapsulated by the back panel, the foil bag, and the outer CMC panel. The use of a CMC material for the outer panel in conjunction with the insulative bag assembly eliminates the need for waterproofing processes, and ultimately allows for more efficient reentry profiles.
Raabe, Margaret E; Chaudhari, Ajit M W
2016-05-03
The ability of a biomechanical simulation to produce results that can translate to real-life situations is largely dependent on the physiological accuracy of the musculoskeletal model. There are a limited number of freely-available, full-body models that exist in OpenSim, and those that do exist are very limited in terms of trunk musculature and degrees of freedom in the spine. Properly modeling the motion and musculature of the trunk is necessary to most accurately estimate lower extremity and spinal loading. The objective of this study was to develop and validate a more physiologically accurate OpenSim full-body model. By building upon three previously developed OpenSim models, the full-body lumbar spine (FBLS) model, comprised of 21 segments, 30 degrees-of-freedom, and 324 musculotendon actuators, was developed. The five lumbar vertebrae were modeled as individual bodies, and coupled constraints were implemented to describe the net motion of the spine. The eight major muscle groups of the lumbar spine were modeled (rectus abdominis, external and internal obliques, erector spinae, multifidus, quadratus lumborum, psoas major, and latissimus dorsi), and many of these muscle groups were modeled as multiple fascicles allowing the large muscles to act in multiple directions. The resulting FBLS model׳s trunk muscle geometry, maximal isometric joint moments, and simulated muscle activations compare well to experimental data. The FBLS model will be made freely available (https://simtk.org/home/fullbodylumbar) for others to perform additional analyses and develop simulations investigating full-body dynamics and contributions of the trunk muscles to dynamic tasks. Copyright © 2016 Elsevier Ltd. All rights reserved.
Growth Patterns of the Neurocentral Synchondrosis (NCS) in Immature Cadaveric Vertebra.
Blakemore, Laurel; Schwend, Richard; Akbarnia, Behrooz A; Dumas, Megan; Schmidt, John
2018-03-01
Gross anatomic study of osteological specimens. To evaluate the age of closure for the neurocentral synchondrosis (NCS) in all 3 regions of the spine in children aged 1 to 18 years old. The ossification of the human vertebra begins from a vertebral body ossification center and a pair of neural ossification centers located within the centrum called the NCS. These bipolar cartilaginous centers of growth contribute to the growth of the vertebral body, spinal canal, and posterior elements of the spine. The closure of the synchondroses is dependent upon location of the vertebra and previous studies range from 2 to 16 years of age. Although animal and cadaveric studies have been performed regarding NCS growth and early instrumentation's effect on its development, the effects of NCS growth disturbances are still not completely understood. The vertebrae of 32 children (1 to 18 y old) from the Hamann-Todd Osteological collection were analyzed (no 2 or 9 y old specimens available). Vertebrae studied ranged from C1 to L5. A total of 768 vertebral specimens were photographed on a background grid to allow for measurement calibration. Measurements of the right and left NCS, pedicle width at the NCS, and spinal canal area were taken using Scandium image-analysis software (Olympus Soft Imaging Solutions, Germany). The percentage of the growth plate still open was found by dividing the NCS by the pedicle width and multiplying by 100. Data were analyzed with JMP 11 software (SAS Institute Inc., Cary, NC). The NCS was 100% open in all 3 regions of the spine in the 1- to 3-year age group. The cervical NCS closed first with completion around 5 years of age. The lumbar NCS was nearly fully closed by age 11. Only the thoracic region remained open through age 17 years. The left and right NCS closed simultaneously as there was no statistical difference between them. In all regions of the spine, the NCS appeared to close sooner in males than in females. Spinal canal area increased with age up to 12 years old in the cervical and thoracic spine but did not significantly change after age 3 in the lumbar spine. In conclusion, closure of the NCS differed among the cervical, thoracic, and lumbar spine regions. The NCS reached closure in males before females even though females mature faster and reach skeletal maturity sooner than males. However, it is not determined whether the continued open NCS in females to a later age may be a factor in their increased rate of scoliosis.
Injury to the Lumbar Plexus and its Branches After Lateral Fusion Procedures: A Cadaver Study.
Grunert, Peter; Drazin, Doniel; Iwanaga, Joe; Schmidt, Cameron; Alonso, Fernando; Moisi, Marc; Chapman, Jens R; Oskouian, Rod J; Tubbs, Richard Shane
2017-09-01
Neurologic deficits from lumbar plexus nerve injuries commonly occur in patients undergoing lateral approaches. However, it is not yet clear what types of injury occur, where anatomically they are located, or what mechanism causes them. We aimed to study 1) the topographic anatomy of lumbar plexus nerves and their injuries in human cadavers after lateral transpsoas approaches to the lumbar spine, 2) the structural morphology of those injuries, and 3) the topographic anatomy of the lumbar plexus throughout the mediolateral approach corridor. Fifteen adult fresh frozen cadaveric torsos (26 sides) underwent lateral approaches (L1-L5) by experienced lateral spine surgeons. The cadavers were subsequently opened and the entire plexus dissected and examined for nerve injuries. The topographic anatomy of the lumbar plexus and its branches, their injuries, and the morphology of these injuries were documented. Fifteen injuries were found with complete or partial nerve transections (Sunderland IV and V). Injuries were found throughout the mediolateral approach corridor. At L1/2, the iliohypogastric, ilioinguinal, and subcostal nerves were injured within the psoas major muscle, the retroperitoneal space, or the outer abdominal muscles and subcutaneous tissues. Genitofemoral nerve injuries were found in the retroperitoneal space. Nerve root injuries occurred within the retroperitoneal space and psoas muscle. Femoral nerve injuries were found only within the psoas major muscle. No obturator nerve injuries occurred. Lateral approaches can lead to structural nerve damage. Knowledge of the complex plexus anatomy, specifically its mediolateral course, is critical to avoid approach-related injuries. Copyright © 2017 Elsevier Inc. All rights reserved.
A CIRCULAR-RIBBON SOLAR FLARE FOLLOWING AN ASYMMETRIC FILAMENT ERUPTION
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Chang; Deng, Na; Lee, Jeongwoo
The dynamic properties of flare ribbons and the often associated filament eruptions can provide crucial information on the flaring coronal magnetic field. This Letter analyzes the GOES-class X1.0 flare on 2014 March 29 (SOL2014-03-29T17:48), in which we found an asymmetric eruption of a sigmoidal filament and an ensuing circular flare ribbon. Initially both EUV images and a preflare nonlinear force-free field model show that the filament is embedded in magnetic fields with a fan-spine-like structure. In the first phase, which is defined by a weak but still increasing X-ray emission, the western portion of the sigmoidal filament arches upward andmore » then remains quasi-static for about five minutes. The western fan-like and the outer spine-like fields display an ascending motion, and several associated ribbons begin to brighten. Also found is a bright EUV flow that streams down along the eastern fan-like field. In the second phase that includes the main peak of hard X-ray (HXR) emission, the filament erupts, leaving behind two major HXR sources formed around its central dip portion and a circular ribbon brightened sequentially. The expanding western fan-like field interacts intensively with the outer spine-like field, as clearly seen in running difference EUV images. We discuss these observations in favor of a scenario where the asymmetric eruption of the sigmoidal filament is initiated due to an MHD instability and further facilitated by reconnection at a quasi-null in corona; the latter is in turn enhanced by the filament eruption and subsequently produces the circular flare ribbon.« less
Electrostatic shape-shifting ion optics
Dahl, David A.; Scott, Jill R.; Appelhans, Anthony D.
2006-05-02
Electrostatic shape-shifting ion optics includes an outer electrode that defines an interior region between first and second opposed open ends. A first inner electrode is positioned within the interior region of the outer electrode at about the first open end. A second inner electrode is positioned within the interior region of the outer electrode at about the second open end. A first end cap electrode is positioned at about a first open end of the first inner electrode so that the first end cap electrode substantially encloses the first open end of the first inner electrode. A second end cap electrode is positioned at about a second open end of the second inner electrode so that the second end cap electrode substantially encloses the second open end of the second inner electrode. A voltage source operatively connected to each of the electrodes applies voltage functions to each of the electrodes to produce an electric field within an interior space enclosed by the electrodes.
Intervertebral reaction force prediction using an enhanced assembly of OpenSim models.
Senteler, Marco; Weisse, Bernhard; Rothenfluh, Dominique A; Snedeker, Jess G
2016-01-01
OpenSim offers a valuable approach to investigating otherwise difficult to assess yet important biomechanical parameters such as joint reaction forces. Although the range of available models in the public repository is continually increasing, there currently exists no OpenSim model for the computation of intervertebral joint reactions during flexion and lifting tasks. The current work combines and improves elements of existing models to develop an enhanced model of the upper body and lumbar spine. Models of the upper body with extremities, neck and head were combined with an improved version of a lumbar spine from the model repository. Translational motion was enabled for each lumbar vertebrae with six controllable degrees of freedom. Motion segment stiffness was implemented at lumbar levels and mass properties were assigned throughout the model. Moreover, body coordinate frames of the spine were modified to allow straightforward variation of sagittal alignment and to simplify interpretation of results. Evaluation of model predictions for level L1-L2, L3-L4 and L4-L5 in various postures of forward flexion and moderate lifting (8 kg) revealed an agreement within 10% to experimental studies and model-based computational analyses. However, in an extended posture or during lifting of heavier loads (20 kg), computed joint reactions differed substantially from reported in vivo measures using instrumented implants. We conclude that agreement between the model and available experimental data was good in view of limitations of both the model and the validation datasets. The presented model is useful in that it permits computation of realistic lumbar spine joint reaction forces during flexion and moderate lifting tasks. The model and corresponding documentation are now available in the online OpenSim repository.
Martin, John T; Gullbrand, Sarah E; Fields, Aaron J; Purmessur, Devina; Diwan, Ashish D; Oxland, Thomas R; Chiba, Kazuhiro; Guilak, Farshid; Hoyland, Judith A; Iatridis, James C
2018-03-01
This study investigated current trends in spine publications of the membership of Orthopaedic Research Society Spine Section (ORS3) and the more global and clinically focused International Society for the Study of the Lumbar Spine (ISSLS). The PubMed database was probed to quantify trends in the overall number of articles published, the number of journals these articles were published in, and the number of active scientists producing new manuscripts. We also evaluated trends in flagship spine journals ( Spine , European Spine Journal , and The Spine Journal ) and in the Journal of Orthopaedic Research. The total number of active ORS3 and ISSLS authors and articles published have increased over the last 10 years. These articles are being published in hundreds of distinct journals; the number of journals is also increasing. Members of both societies published their work in Spine more than any other journal. Yet, publications in Spine decreased over the last 5 years for both ORS3 and ISSLS members, while those in European Spine Journal , and The Spine Journal remained unchanged. Furthermore, members of both societies have published in Journal of Orthopaedic Research at a consistent level. The increasing number of manuscripts and journals reflects a characteristic intrinsic to science as a whole-the global scientific workforce and output are growing and new journals are being created to accommodate the demand. These data suggest that existing spine journals do not fully serve the diverse publication needs of ORS3 and ISSLS members and highlight an unmet need for consolidating the premiere basic and translational spine research in an open access spine-specific journal. This analysis was an important part of a decision process by the ORS to introduce JOR Spine.
Cost-effectiveness analysis in minimally invasive spine surgery.
Al-Khouja, Lutfi T; Baron, Eli M; Johnson, J Patrick; Kim, Terrence T; Drazin, Doniel
2014-06-01
Medical care has been evolving with the increased influence of a value-based health care system. As a result, more emphasis is being placed on ensuring cost-effectiveness and utility in the services provided to patients. This study looks at this development in respect to minimally invasive spine surgery (MISS) costs. A literature review using PubMed, the Cost-Effectiveness Analysis (CEA) Registry, and the National Health Service Economic Evaluation Database (NHS EED) was performed. Papers were included in the study if they reported costs associated with minimally invasive spine surgery (MISS). If there was no mention of cost, CEA, cost-utility analysis (CUA), quality-adjusted life year (QALY), quality, or outcomes mentioned, then the article was excluded. Fourteen studies reporting costs associated with MISS in 12,425 patients (3675 undergoing minimally invasive procedures and 8750 undergoing open procedures) were identified through PubMed, the CEA Registry, and NHS EED. The percent cost difference between minimally invasive and open approaches ranged from 2.54% to 33.68%-all indicating cost saving with a minimally invasive surgical approach. Average length of stay (LOS) for minimally invasive surgery ranged from 0.93 days to 5.1 days compared with 1.53 days to 12 days for an open approach. All studies reporting EBL reported lower volume loss in an MISS approach (range 10-392.5 ml) than in an open approach (range 55-535.5 ml). There are currently an insufficient number of studies published reporting the costs of MISS. Of the studies published, none have followed a standardized method of reporting and analyzing cost data. Preliminary findings analyzing the 14 studies showed both cost saving and better outcomes in MISS compared with an open approach. However, more Level I CEA/CUA studies including cost/QALY evaluations with specifics of the techniques utilized need to be reported in a standardized manner to make more accurate conclusions on the cost effectiveness of minimally invasive spine surgery.
Smith, Katharine R.; Kopeikina, Katherine J.; Fawcett-Patel, Jessica M.; Leaderbrand, Katherine; Gao, Ruoqi; Schürmann, Britta; Myczek, Kristoffer; Radulovic, Jelena; Swanson, Geoffrey T.; Penzes, Peter
2014-01-01
Summary Recent evidence implicates glutamatergic synapses as key pathogenic sites in psychiatric disorders. Common and rare variants in the ANK3 gene, encoding ankyrin-G, have been associated with bipolar disorder, schizophrenia, and autism. Here we demonstrate that ankyrin-G is integral to AMPAR-mediated synaptic transmission and maintenance of spine morphology. Using super-resolution microscopy we find that ankyrin-G forms distinct nanodomain structures within the spine head and neck. At these sites, it modulates mushroom spine structure and function, likely as a perisynaptic scaffold and barrier within the spine neck. Neuronal activity promotes ankyrin-G accumulation in distinct spine subdomains, where it differentially regulates NMDA receptor-dependent plasticity. These data implicate subsynaptic nanodomains containing a major psychiatric risk molecule, ankyrin-G, as having location-specific functions, and opens directions for basic and translational investigation of psychiatric risk molecules. PMID:25374361
Rotary piston engine equipped with an improved air or fuel injection opening
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sasaki, Y.
An improved air or fuel injection opening is described for a rotary piston engine having a trochoidal inner surface of a center housing and an eccentrically rotating polygonal rotor. The air or fuel injection opening provided in a side housing wall is confined within a region limited so as to be outside of an outer envelope of traces of a side seal and inside an outer corner seal, with the opening having a contour smaller than that of the corner seal.
Martin, John T.; Gullbrand, Sarah E.; Fields, Aaron J.; Purmessur, Devina; Diwan, Ashish D.; Oxland, Thomas R.; Chiba, Kazuhiro; Guilak, Farshid; Hoyland, Judith A.
2018-01-01
This study investigated current trends in spine publications of the membership of Orthopaedic Research Society Spine Section (ORS3) and the more global and clinically focused International Society for the Study of the Lumbar Spine (ISSLS). The PubMed database was probed to quantify trends in the overall number of articles published, the number of journals these articles were published in, and the number of active scientists producing new manuscripts. We also evaluated trends in flagship spine journals (Spine, European Spine Journal, and The Spine Journal) and in the Journal of Orthopaedic Research. The total number of active ORS3 and ISSLS authors and articles published have increased over the last 10 years. These articles are being published in hundreds of distinct journals; the number of journals is also increasing. Members of both societies published their work in Spine more than any other journal. Yet, publications in Spine decreased over the last 5 years for both ORS3 and ISSLS members, while those in European Spine Journal, and The Spine Journal remained unchanged. Furthermore, members of both societies have published in Journal of Orthopaedic Research at a consistent level. The increasing number of manuscripts and journals reflects a characteristic intrinsic to science as a whole—the global scientific workforce and output are growing and new journals are being created to accommodate the demand. These data suggest that existing spine journals do not fully serve the diverse publication needs of ORS3 and ISSLS members and highlight an unmet need for consolidating the premiere basic and translational spine research in an open access spine‐specific journal. This analysis was an important part of a decision process by the ORS to introduce JOR Spine. PMID:29770804
Hsu, Cheng-Ting
1984-01-01
A tornado type wind turbine has a vertically disposed wind collecting tower with spaced apart inner and outer walls and a central bore. The upper end of the tower is open while the lower end of the structure is in communication with a wind intake chamber. An opening in the wind chamber is positioned over a turbine which is in driving communication with an electrical generator. An opening between the inner and outer walls at the lower end of the tower permits radially flowing air to enter the space between the inner and outer walls while a vertically disposed opening in the wind collecting tower permits tangentially flowing air to enter the central bore. A porous portion of the inner wall permits the radially flowing air to interact with the tangentially flowing air so as to create an intensified vortex flow which exits out of the top opening of the tower so as to create a low pressure core and thus draw air through the opening of the wind intake chamber so as to drive the turbine.
Postembryonic development of Antygomonas incomitata (Kinorhyncha: Cyclorhagida).
Sørensen, Martin V; Accogli, Gianluca; Hansen, Jesper G
2010-07-01
Postembryonic development in the kinorhynch species Antygomonas incomitata was examined using scanning electron microscopy. The morphology of the six juvenile stages, J-1 to J-6, varies at numerous details, but they can also be distinguished by a few key characters. Juvenile stage 1 by its composition of only nine trunk segments; J-2 by the combination of possessing 10 trunk segments, but no cuspidate spines on segment 9; J-3 by the presence of cuspidate spines on segment 9, but only one pair of cuspidate spines on segment 8; J-4 by the combination of 10 trunk segments only, but having two pairs of cuspidate spines on segment 8; J-5 by possessing 11 trunk segments and same spine compositions as adults but is still maintaining postmarginal spiculae; J-6 specimens closely resemble adults and are most easily identified by their reduced trunk lengths. New segments are formed in a growth zone in the anterior part of the terminal segment. The complete number of segments is reached in J-5. Development of cuticular head and trunk structures are described through all postembryonic stages and following developmental patterns could be outlined: the mouth cone possesses outer oral styles from J-1, but in J-1 to J-3, the styles alternate in size. Scalids of the introvert are added after each molt, and scalids appear earliest in the anterior rings, whereas scalids in more posterior rings are added in older postembryonic stages. The early J-1 stage is poor in spines and sensory spots and both structures increase in number after each molt. The complete spine composition is reached in J-4, whereas new sensory spots appear after all molts, inclusive the final one from J-6 to adult. Sensory spots in the paraventral positions often appear as Type 3 sensory spots but are through development transformed to Type 2. This transformation happens earliest on the anterior segments.
Turbine stator vane segment having internal cooling circuits
Jones, Raymond Joseph; Burns, James Lee; Bojappa, Parvangada Ganapathy; Jones, Schotsch Margaret
2003-01-01
A turbine stator vane includes outer and inner walls each having outer and inner chambers and a vane extending between the outer and inner walls. The vane includes first, second, third, fourth and fifth cavities for flowing a cooling medium. The cooling medium enters the outer chamber of the outer wall, flows through an impingement plate for impingement cooling of the outer band wall defining in part the hot gas path and through openings in the first, second and fourth cavities for flow radially inwardly, cooling the vane. The spent cooling medium flows into the inner wall and inner chamber for flow through an impingement plate radially outwardly to cool the inner wall. The spent cooling medium flows through the third cavity for egress from the turbine vane segment from the outer wall. The first, second or third cavities contain inserts having impingement openings for impingement cooling of the vane walls. The fifth cavity provides air cooling for the trailing edge.
A sonographic approach to prenatal classification of congenital spine anomalies
Robertson, Meiri; Sia, Sock Bee
2015-01-01
Abstract Objective: To develop a classification system for congenital spine anomalies detected by prenatal ultrasound. Methods: Data were collected from fetuses with spine abnormalities diagnosed in our institution over a five‐year period between June 2005 and June 2010. The ultrasound images were analysed to determine which features were associated with different congenital spine anomalies. Findings of the prenatal ultrasound images were correlated with other prenatal imaging, post mortem findings, post mortem imaging, neonatal imaging, karyotype, and other genetic workup. Data from published case reports of prenatal diagnosis of rare congenital spine anomalies were analysed to provide a comprehensive work. Results: During the study period, eighteen cases of spine abnormalities were diagnosed in 7819 women. The mean gestational age at diagnosis was 18.8w ± 2.2 SD. While most cases represented open NTD, a spectrum of vertebral abnormalities were diagnosed prenatally. These included hemivertebrae, block vertebrae, cleft or butterfly vertebrae, sacral agenesis, and a lipomeningocele. The most sensitive features for diagnosis of a spine abnormality included flaring of the vertebral arch ossification centres, abnormal spine curvature, and short spine length. While reported findings at the time of diagnosis were often conservative, retrospective analysis revealed good correlation with radiographic imaging. 3D imaging was found to be a valuable tool in many settings. Conclusions: Analysis of the study findings showed prenatal ultrasound allowed detection of disruption to the normal appearances of the fetal spine. Using the three features of flaring of the vertebral arch ossification centres, abnormal spine curvature, and short spine length, an algorithm was devised to aid with the diagnosis of spine anomalies for those who perform and report prenatal ultrasound. PMID:28191204
Eddy Current Minimizing Flow Plug for Use in Flow Conditioning and Flow Metering
NASA Technical Reports Server (NTRS)
England, John Dwight (Inventor); Kelley, Anthony R. (Inventor)
2015-01-01
An eddy-current-minimizing flow plug has an outer radial wall with open flow channels formed between the plug's inlet and outlet. The plug has a central region coupled to the inner surface of the outer radial wall. Each open flow channel includes (i) a first portion originating at the inlet and converging to a location in the plug where convergence is contributed to by changes in thickness of the outer radial wall and divergence of the central region, and (ii) a second portion originating in the plug and diverging to the outlet where divergence is contributed to by changes in thickness of the outer radial wall and convergence of the central region. For at least a portion of the open flow channels, a central axis passing through the first and second portions is non-parallel with respect to the given direction of the flow.
Higa, Yukiko; Toma, Takako; Miyagi, Ichiro
2012-12-01
We describe and illustrate for the 1st time the pupa and larva of adult female Ficalbia ichiromiyagii based on specimens collected from a swamp forest in Otomi, Iriomote Island, Ryukyu Archipelago, Japan. The pupa has a trumpet that is 6.25 times its breadth at halfway, with a long meatal cleft line; setae 6-I, II considerably long, usually single or bifid; median caudal seta absent; and paddle edge serrated only on the outer apical half. The larva is characterized by dark pigmentation of the head and siphon, seta I-C elongate and spiniform, usually with a short lateral spine on the inner basal side and siphon with 1 pecten spine and conspicuous seta 1-S at the base. The immature stages were found only in undisturbed jungle swamps with dense vegetation.
Abnormal intrinsic dynamics of dendritic spines in a fragile X syndrome mouse model in vivo.
Nagaoka, Akira; Takehara, Hiroaki; Hayashi-Takagi, Akiko; Noguchi, Jun; Ishii, Kazuhiko; Shirai, Fukutoshi; Yagishita, Sho; Akagi, Takanori; Ichiki, Takanori; Kasai, Haruo
2016-05-25
Dendritic spine generation and elimination play an important role in learning and memory, the dynamics of which have been examined within the neocortex in vivo. Spine turnover has also been detected in the absence of specific learning tasks, and is frequently exaggerated in animal models of autistic spectrum disorder (ASD). The present study aimed to examine whether the baseline rate of spine turnover was activity-dependent. This was achieved using a microfluidic brain interface and open-dura surgery, with the goal of abolishing neuronal Ca(2+) signaling in the visual cortex of wild-type mice and rodent models of fragile X syndrome (Fmr1 knockout [KO]). In wild-type and Fmr1 KO mice, the majority of baseline turnover was found to be activity-independent. Accordingly, the application of matrix metalloproteinase-9 inhibitors selectively restored the abnormal spine dynamics observed in Fmr1 KO mice, without affecting the intrinsic dynamics of spine turnover in wild-type mice. Such findings indicate that the baseline turnover of dendritic spines is mediated by activity-independent intrinsic dynamics. Furthermore, these results suggest that the targeting of abnormal intrinsic dynamics might pose a novel therapy for ASD.
Epstein, Nancy E.
2016-01-01
Background: In the lumbar spine, do more nerve root injuries occur utilizing minimally invasive surgery (MIS) techniques versus open lumbar procedures? To answer this question, we compared the frequency of nerve root injuries for multiple open versus MIS operations including diskectomy, laminectomy with/without fusion addressing degenerative disc disease, stenosis, and/or degenerative spondylolisthesis. Methods: Several of Desai et al. large Spine Patient Outcomes Research Trial studies showed the frequency for nerve root injury following an open diskectomy ranged from 0.13% to 0.25%, for open laminectomy/stenosis with/without fusion it was 0%, and for open laminectomy/stenosis/degenerative spondylolisthesis with/without fusion it was 2%. Results: Alternatively, one study compared the incidence of root injuries utilizing MIS transforaminal lumbar interbody fusion (TLIF) versus posterior lumbar interbody fusion (PLIF) techniques; 7.8% of PLIF versus 2% of TLIF patients sustained root injuries. Furthermore, even higher frequencies of radiculitis and nerve root injuries occurred during anterior lumbar interbody fusions (ALIFs) versus extreme lateral interbody fusions (XLIFs). These high frequencies were far from acceptable; 15.8% following ALIF experienced postoperative radiculitis, while 23.8% undergoing XLIF sustained root/plexus deficits. Conclusions: This review indicates that MIS (TLIF/PLIF/ALIF/XLIF) lumbar surgery resulted in a higher incidence of root injuries, radiculitis, or plexopathy versus open lumbar surgical techniques. Furthermore, even a cursory look at the XLIF data demonstrated the greater danger posed to neural tissue by this newest addition to the MIS lumbar surgical armamentariu. The latter should prompt us as spine surgeons to question why the XLIF procedure is still being offered to our patients? PMID:26904372
Miller, David H [Redondo Beach, CA; Korich, Mark D [Chino Hills, CA; Smith, Gregory S [Woodland Hills, CA
2011-11-15
Power inverters include a frame and a power module. The frame has a sidewall including an opening and defining a fluid passageway. The power module is coupled to the frame over the opening and includes a substrate, die, and an encasement. The substrate includes a first side, a second side, a center, an outer periphery, and an outer edge, and the first side of the substrate comprises a first outer layer including a metal material. The die are positioned in the substrate center and are coupled to the substrate first side. The encasement is molded over the outer periphery on the substrate first side, the substrate second side, and the substrate outer edge and around the die. The encasement, coupled to the substrate, forms a seal with the metal material. The second side of the substrate is positioned to directly contact a fluid flowing through the fluid passageway.
Micro-cone targets for producing high energy and low divergence particle beams
Le Galloudec, Nathalie
2013-09-10
The present invention relates to micro-cone targets for producing high energy and low divergence particle beams. In one embodiment, the micro-cone target includes a substantially cone-shaped body including an outer surface, an inner surface, a generally flat and round, open-ended base, and a tip defining an apex. The cone-shaped body tapers along its length from the generally flat and round, open-ended base to the tip defining the apex. In addition, the outer surface and the inner surface connect the base to the tip, and the tip curves inwardly to define an outer surface that is concave, which is bounded by a rim formed at a juncture where the outer surface meets the tip.
Turbine blade vibration dampening
Cornelius, C.C.; Pytanowski, G.P.; Vendituoli, J.S.
1997-07-08
The present turbine wheel assembly increases component life and turbine engine longevity. The combination of the strap and the opening combined with the preestablished area of the outer surface of the opening and the preestablished area of the outer circumferential surface of the strap and the friction between the strap and the opening increases the life and longevity of the turbine wheel assembly. Furthermore, the mass ``M`` or combined mass ``CM`` of the strap or straps and the centrifugal force assist in controlling vibrations and damping characteristics. 5 figs.
Turbine blade vibration dampening
Cornelius, Charles C.; Pytanowski, Gregory P.; Vendituoli, Jonathan S.
1997-07-08
The present turbine wheel assembly increases component life and turbine engine longevity. The combination of the strap and the opening combined with the preestablished area of the outer surface of the opening and the preestablished area of the outer circumferential surface of the strap and the friction between the strap and the opening increases the life and longevity of the turbine wheel assembly. Furthermore, the mass "M" or combined mass "CM" of the strap or straps and the centrifugal force assist in controlling vibrations and damping characteristics.
Cooled airfoil in a turbine engine
Vitt, Paul H; Kemp, David A; Lee, Ching-Pang; Marra, John J
2015-04-21
An airfoil in a gas turbine engine includes an outer wall and an inner wall. The outer wall includes a leading edge, a trailing edge opposed from the leading edge in a chordal direction, a pressure side, and a suction side. The inner wall is coupled to the outer wall at a single chordal location and includes portions spaced from the pressure and suction sides of the outer wall so as to form first and second gaps between the inner wall and the respective pressure and suction sides. The inner wall defines a chamber therein and includes openings that provide fluid communication between the respective gaps and the chamber. The gaps receive cooling fluid that provides cooling to the outer wall as it flows through the gaps. The cooling fluid, after traversing at least substantial portions of the gaps, passes into the chamber through the openings in the inner wall.
Two Episodes of Magnetic Reconnections during a Confined Circular-ribbon Flare
NASA Astrophysics Data System (ADS)
Li, Ting; Yang, Shuhong; Zhang, Qingmin; Hou, Yijun; Zhang, Jun
2018-06-01
We analyze a unique event with an M1.8 confined circular-ribbon flare on 2016 February 13, with successive formations of two circular ribbons at the same location. The flare had two distinct phases of UV and extreme ultraviolet emissions with an interval of about 270 s, of which the second peak was energetically more important. The first episode was accompanied by the eruption of a mini-filament and the fast elongation motion of a thin circular ribbon (CR1) along the counterclockwise direction at a speed of about 220 km s‑1. Two elongated spine-related ribbons were also observed, with the inner ribbon co-temporal with CR1 and the remote brightenings forming ∼20 s later. In the second episode, another mini-filament erupted and formed a blowout jet. The second circular ribbon and two spine-related ribbons showed similar elongation motions with that during the first episode. The extrapolated three-dimensional coronal magnetic fields reveal the existence of a fan-spine topology, together with a quasi-separatrix layer (QSL) halo surrounding the fan plane and another QSL structure outlining the inner spine. We suggest that continuous null-point reconnection between the filament and ambient open field occurs in each episode, leading to the sequential opening of the filament and significant shifts of the fan plane footprint. For the first time, we propose a compound eruption model of circular-ribbon flares consisting of two sets of successively formed ribbons and eruptions of multiple filaments in a fan-spine-type magnetic configuration.
Zuckerman, Scott L; Laufer, Ilya; Sahgal, Arjun; Yamada, Yoshiya J; Schmidt, Meic H; Chou, Dean; Shin, John H; Kumar, Naresh; Sciubba, Daniel M
2016-10-15
Systematic review. The aim of this study was to review the techniques, indications, and outcomes of minimally invasive surgery (MIS) and separation surgery with subsequent radiosurgery in the treatment of patients with metastatic spine disease. The utilization of MIS techniques in patients with spine metastases is a growing area within spinal oncology. Separation surgery represents a novel paradigm where radiosurgery provides long-term control after tumor is surgically separated from the neural elements. PubMed, Embase, and CINAHL databases were systematically queried for literature reporting MIS techniques or separation surgery in patients with metastatic spine disease. PRISMA guidelines were followed. Of the initial 983 articles found, 29 met inclusion criteria. Twenty-five articles discussed MIS techniques and were grouped according to the primary objective: percutaneous stabilization (8), tubular retractors (4), mini-open approach (8), and thoracoscopy/endoscopy (5). The remaining 4 studies reported separation surgery. Indications were similar across all studies and included patients with instability, refractory pain, or neurologic compromise. Intraoperative variables, outcomes, and complications were similar in MIS studies compared to traditional approaches, and some MIS studies showed a statistically significant improvement in outcomes. Studies of mini-open techniques had the strongest evidence for superiority. Low-quality evidence currently exists for MIS techniques and separation surgery in the treatment of metastatic spine disease. Given the early promising results, the next iteration of research should include higher-quality studies with sufficient power, and will be able to provide higher-level evidence on the outcomes of MIS approaches and separation surgery. N/A.
Flux rope breaking and formation of a rotating blowout jet
NASA Astrophysics Data System (ADS)
Joshi, Navin Chandra; Nishizuka, Naoto; Filippov, Boris; Magara, Tetsuya; Tlatov, Andrey G.
2018-05-01
We analysed a small flux rope eruption converted into a helical blowout jet in a fan-spine configuration using multiwavelength observations taken by Solar Dynamics Observatory, which occurred near the limb on 2016 January 9. In our study, first, we estimated the fan-spine magnetic configuration with the potential-field calculation and found a sinistral small filament inside it. The filament along with the flux rope erupted upwards and interacted with the surrounding fan-spine magnetic configuration, where the flux rope breaks in the middle section. We observed compact brightening, flare ribbons, and post-flare loops underneath the erupting filament. The northern section of the flux rope reconnected with the surrounding positive polarity, while the southern section straightened. Next, we observed the untwisting motion of the southern leg, which was transformed into a rotating helical blowout jet. The sign of the helicity of the mini-filament matches the one of the rotating jets. This is consistent with recent jet models presented by Adams et al. and Sterling et al. We focused on the fine thread structure of the rotating jet and traced three blobs with the speed of 60-120 km s- 1, while the radial speed of the jet is ˜400 km s- 1. The untwisting motion of the jet accelerated plasma upwards along the collimated outer spine field lines, and it finally evolved into a narrow coronal mass ejection at the height of ˜9Rsun. On the basis of detailed analysis, we discussed clear evidence of the scenario of the breaking of the flux rope and the formation of the helical blowout jet in the fan-spine magnetic configuration.
Johnson, Jeffrey W; Wilmer, Jessica Worthington
2018-03-01
Three new species of pinguipedid fishes from northern Australia are described based on specimens collected by deep water demersal trawling. Parapercis algrahami sp. nov. is recorded from off Dunk Island, Qld, south to Newcastle, NSW, in 67-333 m. It is distinct in having five narrow transverse dark bars across the upper body and a dark spot dorsally on the caudal-fin base, 6 canine teeth in outer row at front of lower jaw, palatines with 1-2 rows of teeth, and predorsal scales extending far forward on the nape to the posterior portion of the interorbital region. Parapercis imamurai sp. nov. is recorded from off Saumarez Reef, Qld, south to off Coffs Harbour, NSW, in 256-405 m. It is unique in having colouration that includes a broad dusky bar from lower margin of eye across the suborbital region and three broad dusky bands crossing the body between the middle of the soft dorsal-fin and the caudal-fin base, 10 canine teeth in outer row at front of lower jaw, and the fifth dorsal-fin spine longest. Parapercis pogonoskii sp. nov. is unique in having a combination of three reddish-brown vertical bars on the upper body between the anterior and posterior portions of the soft dorsal fin, the soft dorsal fin with two large dusky blotches and caudal-fin base with a dusky blotch in the upper corner, 8-10 canine teeth in outer row at front of lower jaw, fifth dorsal-fin spine longest, angle of subopercle with a single broad spine, and angle of preopercle with 4-5 large widely-separated spines. Comparison of the mitochondrial cytochrome c oxidase subunit 1 (CO 1) genetic marker utilised in DNA barcoding produced significant genetic divergences of at least 8.1% and 14.1% between P. algrahami sp. nov. and P. pogonoskii sp. nov. respectively and their closest sampled congeners. The geographic range of Parapercis rubromaculata Ho, Chang Shao, 2012 is extended from Taiwan to the southern hemisphere waters off Western Australia, based on specimens collected from Shark Bay, north to Ashmore Terrace, in depths of 56-107 m. A revised diagnosis for the species is presented, meristic, morphometric and DNA barcoding data for the two populations are compared, and a detailed description of the colouration of fresh and preserved specimens from Australia is provided. Previous records of Parapercis macrophthalma (Pietschmann, 1911) from Western Australia are established as misidentifications of Parapercis muronis (Tanaka, 1918) and the latter is thereby confirmed from the southern hemisphere and Australian waters for the first time. Comparative meristic, morphometric and DNA barcoding data is provided for populations of P. muronis from Japan, Philippines and Western Australia.
Lumbar spine disc heights and curvature: upright posture vs. supine compression harness
NASA Technical Reports Server (NTRS)
Lee, Shi-Uk; Hargens, Alan R.; Fredericson, Michael; Lang, Philipp K.
2003-01-01
INTRODUCTION: Spinal lengthening in microgravity is thought to cause back pain in astronauts. A spinal compression harness can compress the spine to eliminate lengthening but the loading condition with harness is different than physiologic conditions. Our purpose was to compare the effect of spine compression with a harness in supine position on disk height and spinal curvature in the lumbar spine to that of upright position as measured using a vertically open magnetic resonance imaging system. METHODS: Fifteen healthy subjects volunteered. On day 1, each subject lay supine for an hour and a baseline scan of the lumbar spine was performed. After applying a load of fifty percent of body weight with the harness for thirty minutes, the lumbar spine was scanned again. On day 2, after a baseline scan, a follow up scan was performed after kneeling for thirty minutes within the gap between two vertically oriented magnetic coils. Anterior and posterior disk heights, posterior disk bulging, and spinal curvature were measured from the baseline and follow up scans. RESULTS: Anterior disk heights increased and posterior disk heights decreased compared with baseline scans both after spinal compression with harness and upright posture. The spinal curvature increased by both loading conditions of the spine. DISCUSSION: The spinal compression with specially designed harness has the same effect as the physiologic loading of the spine in the kneeling upright position. The harness shows some promise as a tool to increase the diagnostic capabilities of a conventional MR system.
Airway management of patients with traumatic brain injury/C-spine injury
2015-01-01
Traumatic brain injury (TBI) is usually combined with cervical spine (C-spine) injury. The possibility of C-spine injury is always considered when performing endotracheal intubation in these patients. Rapid sequence intubation is recommended with adequate sedative or analgesics and a muscle relaxant to prevent an increase in intracranial pressure during intubation in TBI patients. Normocapnia and mild hyperoxemia should be maintained to prevent secondary brain injury. The manual-in-line-stabilization (MILS) technique effectively lessens C-spine movement during intubation. However, the MILS technique can reduce mouth opening and lead to a poor laryngoscopic view. The newly introduced video laryngoscope can manage these problems. The AirWay Scope® (AWS) and AirTraq laryngoscope decreased the extension movement of C-spines at the occiput-C1 and C2-C4 levels, improving intubation conditions and shortening the time to complete tracheal intubation compared with a direct laryngoscope. The Glidescope® also decreased cervical movement in the C2-C5 levels during intubation and improved vocal cord visualization, but a longer duration was required to complete intubation compared with other devices. A lightwand also reduced cervical motion across all segments. A fiberoptic bronchoscope-guided nasal intubation is the best method to reduce cervical movement, but a skilled operator is required. In conclusion, a video laryngoscope assists airway management in TBI patients with C-spine injury. PMID:26045922
[Diagnostic and Treatment Strategies in Morel-Lavallee Lesions in the Spinal Column and Pelvis].
Becker, Christopher A; Kammerlander, Christian; Greiner, Axel; Sommer, Fabian; Linhart, Christoph; Böcker, Wolfgang; Rubenbauer, Bianka; Weidert, Simon
2018-04-12
The Morel-Lavallée lesion is one of the concomitant soft tissue lesions of pelvic fractures. Its role in spine fractures and its treatment in combination with osteosynthesis of pelvic or spine fractures have not yet been determined. The aim of this study was to analyse the best diagnostic and treatment options of both spine and pelvic fractures combined with Morel-Lavallée lesions (MLL). An analysis of the literature was performed via PubMed and Medline. This revealed a total of 197 studies and case reports. After analysing the literature, 19 studies/case reports met our inclusion criteria. There are several diagnostic options for MLL, including ultrasound, computed tomography or MRI. In spinal and pelvic lesions, ultrasound is capable of detecting MLL. Some authors tend to perform open debridement of the MLL, whereas others recommend percutanous treatment. Open debridement and vacuum-assisted closure are recommended in late diagnosed MLL, where primary suture of the soft tissue is impossible. Fracture fixation should be performed simultaneously to treatment of the MLL. Broad-spectrum cephalosporins combined with an aminoglycoside or piperacilline/tazobactam should be initiated. Radical debridement and drainage are recommended, especially when MLL is diagnosed late. Repeated ultrasound examinations should be performed of the surrounding soft tissue of the fracture. When MLL is diagnosed within 2 days, percutanous fracture and MLL treatment should be performed. After more than 2 days, both fracture and MLL should be treated with open debridement, open fracture fixation and primary suture if possible. Georg Thieme Verlag KG Stuttgart · New York.
Wiesner, E L; Hillen, T J; Long, J; Jennings, J W
2018-05-01
Cervical spine biopsies can be challenging due to the anatomy and the adjacent critical structures. Percutaneous image-guided biopsies can obviate the need for an open biopsy, however there have been few studies looking at the approaches, safety, and efficacy of percutaneous cervical spine biopsies. This retrospective study evaluated technical considerations, histopathologic and microbiologic yield, and safety in CT-guided cervical bone biopsies. A retrospective review of cervical bone and/or bone/disc biopsies performed from January 2010 to January 2017 was included in this study. Clinical diagnosis and indication, patient demographics, biopsy location, biopsy needle type, technical approach, lesion size, dose-length product, conscious sedation details, complications, and diagnostic histopathologic and/or microbiologic yield were recorded for each case and summarized. A total of 73 patients underwent CT-guided cervical bone biopsies. Fifty-three percent (39/73) were for clinical/imaging concern for infection and 47% (34/73) were for primary tumors or metastatic disease. Thirty-four percent (25/73) were of the inferior cervical spine (ie, C6 and C7). A sufficient sample was obtained for histopathologic and microbiologic analyses in 96% (70/73) of the biopsies. Forty-six percent (18/39) of those samples taken for infection had positive cultures. Two intraprocedural complications occurred in which the patients became hypotensive during the procedure without long-term complications. Percutaneous CT-guided biopsy of the cervical spine is an effective and safe procedure with high diagnostic yield and can obviate open procedures for histopathologic and microbiologic analyses of patients with clinical and imaging findings concerning for infection or primary and metastatic osseous lesions. © 2018 by American Journal of Neuroradiology.
The Effects of rhBMP-2 Used for Spinal Fusion on Spinal Cord Pathology After Traumatic Injury
2009-07-29
1219-1224; discussion 1225. Basso DM , Beattie MS, Bresnahan JC (1995) A sensitive and reliable locomotor rating scale for open field testing in rats...usage of rhBMP-2 in the anterior cervical spine. Spine 31:2813-2819. Stuesse SL, Crisp T, McBurney DL, Schechter JB, Lovell JA, Cruce WL (2001...250-256. Stuesse SL, Crisp T, McBurney DL, Schechter JB, Lovell JA, Cruce WL (2001) Neuropathic pain in aged rats: behavioral responses and
INTERACTION OF TWO FILAMENT CHANNELS OF DIFFERENT CHIRALITIES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, Navin Chandra; Magara, Tetsuya; Moon, Yong-Jae
2016-07-10
We present observations of the interactions between the two filament channels of different chiralities and associated dynamics that occurred during 2014 April 18–20. While two flux ropes of different helicity with parallel axial magnetic fields can only undergo a bounce interaction when they are brought together, the observations at first glance show that the heated plasma is moving from one filament channel to the other. The SDO /AIA 171 Å observations and the potential-field source-surface magnetic field extrapolation reveal the presence of a fan-spine magnetic configuration over the filament channels with a null point located above them. Three different eventsmore » of filament activations, partial eruptions, and associated filament channel interactions have been observed. The activation initiated in one filament channel seems to propagate along the neighboring filament channel. We believe that the activation and partial eruption of the filaments brings the field lines of flux ropes containing them closer to the null point and triggers the magnetic reconnection between them and the fan-spine magnetic configuration. As a result, the hot plasma moves along the outer spine line toward the remote point. Utilizing the present observations, for the first time we have discussed how two different-chirality filament channels can interact and show interrelation.« less
NASA Astrophysics Data System (ADS)
Janiak, M.; Sikora, M.; Moderski, R.
2016-05-01
We present a detailed Fermi/LAT data analysis for the broad-line radio galaxy 3C 120. This source has recently entered into a state of increased γ-ray activity which manifested itself in two major flares detected by Fermi/LAT in 2014 September and 2015 April with no significant flux changes reported in other wavelengths. We analyse available data focusing our attention on aforementioned outbursts. We find very fast variability time-scale during flares (of the order of hours) together with a significant γ-ray flux increase. We show that the ˜6.8 yr averaged γ-ray emission of 3C 120 is likely a sum of the external radiation Compton and the synchrotron self-Compton radiative components. To address the problem of violent γ-ray flares and fast variability we model the jet radiation dividing the jet structure into two components: the wide and relatively slow outer layer and the fast, narrow spine. We show that with the addition of the fast spine occasionally bent towards the observer we are able to explain observed spectral energy distribution of 3C 120 during flares with the Compton upscattered broad-line region and dusty torus photons as main γ-rays emission mechanism.
Revision of the genus Verilus (Perciformes: Acropomatidae) with a description of a new species.
Yamanoue, Y
2016-11-01
The acropomatid genus Verilus is redescribed as a senior synonym of Apogonops and Neoscombrops with description of a new species and a taxonomic revision of the five species that were formerly classified in these genera. This genus is characterized by the following combination of characters: a canine tooth (rarely two) near symphysis of premaxilla of upper jaw but lacking a row of conical teeth on anterior part of outer premaxillary margin; a canine tooth (rarely two) near symphysis of dentary with only villiform or a row of conical teeth posteriorly; three anal-fin spines; 10 dorsal-fin spines; pelvic-fin spine smooth; luminous organ absent. This genus comprises six species: Verilus sordidus (type species, western Atlantic Ocean); Verilus anomalus (off southern and eastern coast of Australia); Verilus atlanticus (western Atlantic Ocean); Verilus cynodon (south-western Indian Ocean); Verilus pacificus (north-western and central Pacific Ocean); Verilus starnesi sp. nov. (Coral Sea off Chesterfield Islands, New Caledonia). These species are distinguishable from one another by dentition on the lower jaw, numbers of pectoral-fin rays, gill rakers and lateral-line scales, features of the proximal-middle radial of the first anal-fin pterygiophore, presence or absence of basioccipital fossa and body depth. © 2016 The Fisheries Society of the British Isles.
Gas turbine engine exhaust diffuser including circumferential vane
Orosa, John A.; Matys, Pawel
2015-05-19
A flow passage defined between an inner and an outer boundary for guiding a fluid flow in an axial direction. A flow control vane is supported at a radial location between the inner and outer boundaries. A fluid discharge opening is provided for discharging a flow of the compressed fluid from a trailing edge of the vane, and a fluid control surface is provided adjacent to the fluid discharge opening and extends in the axial direction at the trailing edge of the vane. The fluid control surface has a curved trailing edge forming a Coanda surface. The fluid discharge opening is selectively provided with a compressed fluid to produce a Coanda effect along the control surface. The Coanda effect has a component in the radial direction effecting a turning of the fluid flow in the flow path radially inward or outward toward one of the inner and outer boundaries.
Koh, Jae-Chul; Lee, Jong Seok; Lee, Youn-Woo; Chang, Chul Ho
2010-11-01
For patients suspicious of cervical spine injury, a Philadelphia cervical collar is usually applied. Application of Philadelphia cervical collar may cause difficult airway. The aim of this study was to evaluate the laryngeal view and the success rate at first intubation attempt of the Airtraq and conventional laryngoscopy in patients with simulated cervical spine injury after application of a Philadelphia cervical collar. Anesthesia was induced with propofol, remifentanil, and rocuronium. After a Philadelphia cervical collar applied, patients were randomly assigned to tracheal intubation with an Airtraq (Group A, n = 25) or with conventional laryngoscopy (Group L, n = 25). Measurements included intubation time, success rate of first intubation attempt, number of intubation attempts, and percentage of glottic opening (POGO) score. Mean blood pressure and heart rate were also recorded at baseline, just before and after intubation. The success rate of the first attempt in Group A (96%) was significantly greater than with the Group L (40%). POGO score was significantly greater in Group A (84 ± 20%) than in Group L (6 ± 11%). The duration of successful intubation at first tracheal intubation attempt and hemodynamic changes were not significantly different between the two groups. The Airtraq offers a better laryngeal view and higher success rate at first intubation attempt in patients who are applied with a Philadelphia cervical collar due to suspicion of cervical spine injury.
Concentric wrench for blind access opening in a turbine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laurer, Kurt Neal; Drlik, Gary Joseph; Gibler, Edward Eugene
The concentric wrench includes an outer tube having flats at one end and a gripping surface at an opposite end. An inner tube has interior flats at one end and a gripping surface at its opposite end. With the inner and outer tubes disposed about a pressure transmitting conduit, the tubes may be inserted into a blind access opening in the outer turbine casing to engage the flats of the tubes against hex nuts of an internal fitting. By relatively rotating the tubes using the externally exposed gripping surfaces, the threaded connection between the parts of the fitting bearing themore » respective hex nuts can be tightened or loosened.« less
Liquid-Sensing Probe and Methods for Using the Same
NASA Technical Reports Server (NTRS)
Haberbusch, Mark S. (Inventor); Ickes, Jacob C. (Inventor); Thurn, Adam (Inventor); Lawless, Branden J. (Inventor)
2014-01-01
A sensor assembly includes a main body, a sensor, and a filler. The main body includes an outer surface having a continuously-variable radius of curvature in at least one portion. A sensor in thermal communication with a region of that surface having relatively low radius of curvature is disposed in the assembly recessed from the outer surface. Liquid droplets adhered to the outer surface in this region tend to migrate to a distant location having a higher radius of curvature. The main body has low thermal conductivity. The filler has a relatively higher thermal conductivity and, in embodiments, fills an opening in the outer surface of the main body, providing a thermally-conductive pathway between the sensor and the surrounding environment via the opening. A probe having a plurality of such sensors, and methods of detecting the presence of liquid and phase transitions in a predetermined space are also disclosed.
Momaya, Amit; Rozzelle, Curtis; Davis, Kenny; Estes, Reed
2014-06-01
Cervical spine injuries are uncommon but potentially devastating athletic injuries. We report a case of a girl gymnast who presented with a cervical spine fracture dislocation with posterior ligamentous disruption several days after injury. To our knowledge, this type of presentation with such severity of injury in a gymnast has not been reported in the literature. The patient was performing a double front tuck flip and sustained a hyperflexion, axial-loading injury. She experienced mild transient numbness in her bilateral upper and lower extremities lasting for about 5 minutes, after which it resolved. The patient was neurologically intact during her clinic visit, but she endorsed significant midline cervical tenderness. Plain radiographs and computed tomography imaging of the cervical spine revealed a C2-C3 fracture dislocation. She underwent posterior open reduction followed by C2-C3 facet arthrodesis and internal fixation. This case highlights the importance of very careful evaluations of neck injuries and the maintenance of high suspicion for significant underlying pathology.
Corgosinho, Paulo H C; Kihara, Terue C; Schizas, Nikolaos V; Ostmann, Alexandra; Arbizu, Pedro Martínez; Ivanenko, Viatcheslav N
2018-01-01
Aegisthidae is one of the most abundant and diverse families of harpacticoid copepods living in deep-sea benthos, and the phylogenetic relationships within the family are in state of flux. Females of two new deep-water species of harpacticoid copepods belonging to the Hase gen. n. (Aegisthidae: Cerviniinae) are described. The first taxonomic description of marine copepod species based on the combined use of interference and confocal microscopy for the study of the habitus and dissected appendages is presented here. CLSM (Confocal Laser Scanning Microscopy) is a non-destructive method, comparable in quality to SEM (scanning electron microscopy) at the same magnifications. To observe and reconstruct in detail the habitus and dissected appendages, whole specimens and dissected parts were stained with Congo Red, mounted on slides with glycerine for CLSM and scanned under three visible-light lasers. Hase lagomorphicus gen. et sp. n. and Hase talpamorphicus gen. et sp. n. were collected from the sediments of the Southern Atlantic and the Norwegian Sea, from 2270 m and 5468 m depths, respectively. Hase gen. n. is included within Cerviniinae based on the caudal rami which are relatively divergent. Hase gen. n. is the sister taxon of Cerviniella based on the following synapomorphies: sturdy body, exopodites 1-3 of pereopods 1-3 heavily built, transformed into digging limbs, with strong outer and distal spines/setae, two-segmented endopod on the pereopods 2 and 3, and a reduced pereopod 5. Compared to Cerviniella, Hase gen. n. exhibits a more developed armature on the pereopod 1, which has outer and distal elements transformed into strong and long spines vs. stiff setae on Cerviniella.Hase gen. n. has one or two strong and long spines on the inner margin of the exopodite 3 of pereopod 4 and pereopod 5 is fused to the somite, ornamented with three distal setae. The telson of Hase gen. n. is subquadratic, and the furca is among the shortest yet described for Aegisthidae. The new species differ in a number of diagnostic characters, three of which are: a) the somite bearing pereopods 3 and 4 with latero-distal spiniform processes in H. talpamorphicus gen. et sp. n. but smooth in H. lagomorphicus gen. et sp. n. , b) antenna is armed with three stout spines on the lateral inner margin of the exopod in H. talpamorphicus gen. et sp. n. and two proximal setae in H. lagomorphicus gen. et sp. n. , and c) pereopod 4 exopodite 3 has two long and strong spines on the inner margin in H. lagomorphicus gen. et sp. n. and one spine in H. talpamorphicus gen. et sp. n. The high quality of CLSM images should foster discussion about the use of high quality digital images as type or as part of the type series in zoological studies, especially when studying rare and small macrofaunal and meiofaunal taxa.
Corgosinho, Paulo H. C.; Kihara, Terue C.; Schizas, Nikolaos V.; Ostmann, Alexandra; Arbizu, Pedro Martínez; Ivanenko, Viatcheslav N.
2018-01-01
Abstract Aegisthidae is one of the most abundant and diverse families of harpacticoid copepods living in deep-sea benthos, and the phylogenetic relationships within the family are in state of flux. Females of two new deep-water species of harpacticoid copepods belonging to the Hase gen. n. (Aegisthidae: Cerviniinae) are described. The first taxonomic description of marine copepod species based on the combined use of interference and confocal microscopy for the study of the habitus and dissected appendages is presented here. CLSM (Confocal Laser Scanning Microscopy) is a non-destructive method, comparable in quality to SEM (scanning electron microscopy) at the same magnifications. To observe and reconstruct in detail the habitus and dissected appendages, whole specimens and dissected parts were stained with Congo Red, mounted on slides with glycerine for CLSM and scanned under three visible-light lasers. Hase lagomorphicus gen. et sp. n. and Hase talpamorphicus gen. et sp. n. were collected from the sediments of the Southern Atlantic and the Norwegian Sea, from 2270 m and 5468 m depths, respectively. Hase gen. n. is included within Cerviniinae based on the caudal rami which are relatively divergent. Hase gen. n. is the sister taxon of Cerviniella based on the following synapomorphies: sturdy body, exopodites 1–3 of pereopods 1–3 heavily built, transformed into digging limbs, with strong outer and distal spines/setae, two-segmented endopod on the pereopods 2 and 3, and a reduced pereopod 5. Compared to Cerviniella, Hase gen. n. exhibits a more developed armature on the pereopod 1, which has outer and distal elements transformed into strong and long spines vs. stiff setae on Cerviniella.Hase gen. n. has one or two strong and long spines on the inner margin of the exopodite 3 of pereopod 4 and pereopod 5 is fused to the somite, ornamented with three distal setae. The telson of Hase gen. n. is subquadratic, and the furca is among the shortest yet described for Aegisthidae. The new species differ in a number of diagnostic characters, three of which are: a) the somite bearing pereopods 3 and 4 with latero-distal spiniform processes in H. talpamorphicus gen. et sp. n. but smooth in H. lagomorphicus gen. et sp. n., b) antenna is armed with three stout spines on the lateral inner margin of the exopod in H. talpamorphicus gen. et sp. n. and two proximal setae in H. lagomorphicus gen. et sp. n., and c) pereopod 4 exopodite 3 has two long and strong spines on the inner margin in H. lagomorphicus gen. et sp. n. and one spine in H. talpamorphicus gen. et sp. n. The high quality of CLSM images should foster discussion about the use of high quality digital images as type or as part of the type series in zoological studies, especially when studying rare and small macrofaunal and meiofaunal taxa. PMID:29930476
Effects of whole spine alignment patterns on neck responses in rear end impact.
Sato, Fusako; Odani, Mamiko; Miyazaki, Yusuke; Yamazaki, Kunio; Östh, Jonas; Svensson, Mats
2017-02-17
The aim of this study was to investigate the whole spine alignment in automotive seated postures for both genders and the effects of the spinal alignment patterns on cervical vertebral motion in rear impact using a human finite element (FE) model. Image data for 8 female and 7 male subjects in a seated posture acquired by an upright open magnetic resonance imaging (MRI) system were utilized. Spinal alignment was determined from the centers of the vertebrae and average spinal alignment patterns for both genders were estimated by multidimensional scaling (MDS). An occupant FE model of female average size (162 cm, 62 kg; the AF 50 size model) was developed by scaling THUMS AF 05. The average spinal alignment pattern for females was implemented in the model, and model validation was made with respect to female volunteer sled test data from rear end impacts. Thereafter, the average spinal alignment pattern for males and representative spinal alignments for all subjects were implemented in the validated female model, and additional FE simulations of the sled test were conducted to investigate effects of spinal alignment patterns on cervical vertebral motion. The estimated average spinal alignment pattern was slight kyphotic, or almost straight cervical and less-kyphotic thoracic spine for the females and lordotic cervical and more pronounced kyphotic thoracic spine for the males. The AF 50 size model with the female average spinal alignment exhibited spine straightening from upper thoracic vertebra level and showed larger intervertebral angular displacements in the cervical spine than the one with the male average spinal alignment. The cervical spine alignment is continuous with the thoracic spine, and a trend of the relationship between cervical spine and thoracic spinal alignment was shown in this study. Simulation results suggested that variations in thoracic spinal alignment had a potential impact on cervical spine motion as well as cervical spinal alignment in rear end impact condition.
Hartwein, J
1992-09-01
The acoustic resonance of a severely altered outer ear channel (radical mastoid cavity) is investigated in a series of 18 patients who underwent revision surgery by means of in-situ measurements of the sound-pressure-level near the tympanic membrane. While the average volume of the open cavity differs from the normal ear channel for the factor 2.5, the size of the external meatus is--in average--only 20% larger. This leads to an average frequency in patients with open cavity of 1939 Hz, more than 1000 Hz less than in a series (n = 20) of normal ears (average resonance frequency: 2942 Hz). The altered acoustic behaviour of the open cavity leads to partial extensive discrepancies of the resonance-caused sound-pressure augmentation in the frequencies of 3 and 4 kHz, which are important for speech perception. The average difference is more than 10 dB (SPL). Proved surgical techniques of cavity obliteration and meatoplasty can lead to a nearly normalized acoustic behaviour of the outer ear in a statistic significant way. Due to these surgical procedures, an average postoperative resonance frequency of 2421 Hz could be reached in our patients. Especially, the resonance-caused sound-pressure augmentation in 3-4 kHz could nearly be equalized to such of a normal outer ear. Differences in the acoustic behaviour of the outer ear as can be found between patients with an open mastoid cavity and normal ears can almost be eliminated surgically.(ABSTRACT TRUNCATED AT 250 WORDS)
Turbine inner shroud and turbine assembly containing such inner shroud
Bagepalli, Bharat Sampathkumaran; Corman, Gregory Scot; Dean, Anthony John; DiMascio, Paul Stephen; Mirdamadi, Massoud
2001-01-01
A turbine inner shroud and a turbine assembly. The turbine assembly includes a turbine stator having a longitudinal axis and having an outer shroud block with opposing and longitudinally outward facing first and second sides having open slots. A ceramic inner shroud has longitudinally inward facing hook portions which can longitudinally and radially surround a portion of the sides of the outer shroud block. In one attachment, the hook portions are engageable with, and are positioned within, the open slots.
Packer arrangements for oil wells and the like
Harvey, Andrew C.; McFadden, David H.
1981-11-24
The packer includes an elongated tubular casing, and a metal ring is disposed in its entirety within an annular recess in the casing. The recess has a circumferential opening extending entirely around the peripheral outer surface of the casing. Hydraulic fluid is flowed into the recess to apply pressure to the inner peripheral surface of the metal ring to expand the ring radially outwardly and force its outer peripheral surface through the circumferential opening and into annular sealing engagement with the opposed surface of the well casing.
All-reflective optical target illumination system with high numerical aperture
Sigler, Robert D.
1978-01-01
An all-reflective optical system for providing illumination of a target focal region at high numerical aperture from a pair of co-axially, confluent collimated light beams. A target cavity is defined by a pair of opposed inner ellipsoidal reflectors having respective first focal points within a target region and second focal points at a vertex opening in the opposing reflector. Outwardly of each inner reflector is the opposed combination of a spherical reflector, and an outer generally ellipsoidal reflector having an aberrated first focal point coincident with the focus of the opposing spherical reflector and a second focal point coincident with the second focal point of the opposing inner ellipsoidal reflector through a vertex opening in the spherical reflector. The confluent collimated beams are incident through vertex openings in the outer ellipsoidal reflectors onto respective opposing spherical reflectors. Each beam is reflected by the associated spherical reflector onto the opposing outer ellipsoidal reflector and focused thereby onto the opposing inner ellipsoidal reflector, and then onto the target region.
Verdú-López, Francisco; Beisse, Rudolf
2014-01-01
Thoracoscopic surgery or video-assisted thoracic surgery (VATS) of the thoracic and lumbar spine has evolved greatly since it appeared less than 20 years ago. It is currently used in a large number of processes and injuries. The aim of this article, in its two parts, is to review the current status of VATS of the thoracic and lumbar spine in its entire spectrum. After reviewing the current literature, we developed each of the large groups of indications where VATS takes place, one by one. This second part reviews and discusses the management, treatment and specific thoracoscopic technique in thoracic disc herniation, spinal deformities, tumour pathology, infections of the spine and other possible indications for VATS. Thoracoscopic surgery is in many cases an alternative to conventional open surgery. The transdiaphragmatic approach has made endoscopic treatment of many thoracolumbar junction processes possible, thus widening the spectrum of therapeutic indications. These include the treatment of spinal deformities, spinal tumours, infections and other pathological processes, as well as the reconstruction of injured spinal segments and decompression of the spinal canal if lesion placement is favourable to antero-lateral approach. Good clinical results of thoracoscopic surgery are supported by growing experience reflected in a large number of articles. The degree of complications in thoracoscopic surgery is comparable to open surgery, with benefits in regard to morbidity of the approach and subsequent patient recovery. Copyright © 2012 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.
POST-PUBERTAL DECREASE IN HIPPOCAMPAL DENDRITIC SPINES OF FEMALE RATS
Yildirim, Murat; Mapp, Oni M.; Janssen, William G.M.; Yin, Weiling; Morrison, John H.; Gore, Andrea C.
2011-01-01
Hippocampal dendritic spine and synapse numbers in female rats vary across the estrous cycle and following experimental manipulation of hormone levels in adulthood. Based on behavioral studies demonstrating that learning patterns are altered following puberty, we hypothesized that dendritic spine number in rat hippocampal CA1 region would change post-pubertally. Female Sprague-Dawley rats were divided into prepubertal (postnatal day (P) 22), peripubertal (P35) and post-pubertal (P49) groups, with the progression of puberty evaluated by vaginal opening, and estrous cyclicity subsequently assessed by daily vaginal smears. Spinophilin immunoreactivity in dendritic spines was used as an index of spinogenesis in area CA1 stratum radiatum (CA1sr) of hippocampus. First, electron microscopy analyses confirmed the presence of spinophilin specifically in dendritic spines of CA1sr, supporting spinophilin as a reliable marker of hippocampal spines in young female rats. Second, stereologic analysis was performed to assess the total number of spinophilin-immunoreactive puncta (i.e. spines) and CA1sr volume in developing rats. Our results indicated that the number of spinophilin-immunoreactive spines in CA1sr was decreased 46% in the post-pubertal group compared to the two younger groups, whereas the volume of the hippocampus underwent an overall increase during this same developmental time frame. Third, to determine a potential role of estradiol in this process, an additional group of rats was ovariectomized (OVX) prepubertally at P22, then treated with estradiol or vehicle at P35, and spinophilin quantified as above in rats perfused on P49. No difference in spinophilin puncta number was found in OVX rats between the two hormone groups, suggesting that this developmental decrease is independent of peripheral estradiol. These changes in spine density coincident with puberty may be related to altered hippocampal plasticity and synaptic consolidation at this phase of maturity. PMID:18096161
NASA Astrophysics Data System (ADS)
Breiding, Peter; Georganopoulos, Markos; Meyer, Eileen T.
2018-01-01
Recent multiwavelength work led by the Boston University blazar group (e.g., Marscher et al.) strongly suggests that a fraction of the blazar flares seen by the Fermi Large Area Telescope (LAT) take place a few to several pc away from the central engine. However, at such distances from the central engine, there is no adequate external photon field to provide the seed photons required for producing the observed GeV emission under leptonic inverse Compton (IC) models. A possible solution is a spine-sheath geometry for the emitting region (MacDonald et al., but see Nalewajko et al.). Here we use the current view of the molecular torus (e.g., Elitzur; Netzer), in which the torus extends a few pc beyond the dust sublimation radius with dust clouds distributed with a declining density for decreasing polar angle. We show that for a spine-sheath blazar jet embedded in the torus, the wide beaming pattern of the synchrotron radiation of the relatively slow sheath will heat molecular clouds with subsequent IR radiation that will be highly boosted in the spine comoving frame, and that under reasonable conditions this photon field can dominate over the sheath photons directly entering the spine. If the sheath is sufficiently luminous it will sublimate the dust, and if the sheath synchrotron radiation extends to optical-UV energies (as may happen during flares), this will illuminate the sublimated dust clouds to produce emission lines that will vary in unison with the optical-UV continuum, as has been very recently reported for blazar CTA 102 (Jorstad et al.).
Stankowich, Theodore; Campbell, Lisa A
2016-07-01
Mammals have independently evolved a wide variety of morphological adaptations for use in avoiding death by predation, including spines, quills, dermal plates, and noxious sprays. Although these traits appear to protect their bearer from predatory attack, it is less obvious why some species evolved them and others have not. We investigated the ecological correlates favoring the evolution of specialized defenses in mammals, focusing on conspicuousness to predators due to body size and openness of habitat. We scored species for the degree to which they are protected by spines, quills, dermal plating, and sprays and used phylogenetic comparative analyses to study the morphological and ecological factors that may favor their evolution. We show that medium-sized insectivorous mammals (∼800 g to 9 kg) that live in open habitats are more likely to possess one of these defensive traits to reduce predation. Smaller species (<200 g) and those in closed habitats can typically rely on crypsis to avoid predators, and larger species (>10 kg) are less susceptible to predation by most small- to medium-sized predators. We discuss how diet, metabolic rate, and defensive strategy evolve in concert to allow species to exploit this ecomorphological "danger zone" niche. © 2016 The Author(s).
Modification of First Impression Formation and "Personality" by Manipulating Outer Appearance.
Hüttner, Susanne-Marie; Linden, Michael
2017-01-01
Global impression is the first item in any psychopathological evaluation, as patients often elicit negative responses in other persons by a dysfunctional first impression formation. This can lead to interactional problems and stigmatization. This study tested to what degree the perception of "personality" can be changed by simple manipulations of the outer appearance of a person. A total of 92 persons were given two different photos of the same female, one with hair combed back and the other with "open" curly hair. For each picture they made ratings on the Bipolar MED Rating Scale, which asks for judgements on 23 emotional impressions. The rating on the "two" persons differed significantly for 16 of the 23 items. Curled open hair led to a more open-hearted and trusting impression, while the combed-back hair was perceived as more reserved, earnest, and defiant. Results were independent of age and gender. People come to far-reaching conclusions about the "personality" of other persons (first impression formation) based on the outer appearance. This opens treatment options for improving social interaction and fighting stigma in patients with mental disorders. © 2017 S. Karger AG, Basel.
Ohlinger, L.A.; Seitz, F.; Young, G.J.
1959-02-17
Test-hole construction in a reactor to facilitate inserting and removing test specimens from the reactor for irradiation therein is discussed. An elongated chamber extends from the outer face of the reactor shield into the reactor. A shield box, having an open end, is sealed to thc outer face of the reactor shield by its open end surrounding the outer end of the chamber. A removable door is provided in the side wall of the shield box for inscrtion and removal of test specimens. A means operable from thc exterior of the shield box is provided for transferring test specimens between the shield box and the irradiation position within the chamber and consists of an elongated rod having a specimen tray engaging member on its inner end, which may be manipulated by the operator.
Demetropoulos, C K; Truumees, E; Herkowitz, H N; Yang, K H
2005-05-01
In surgery of the cervical spine, a Caspar pin distractor is often used to apply a tensile load to the spine in order to open up the disc space. This is often done in order to place a graft or other interbody fusion device in the spine. Ideally a tight interference fit is achieved. If the spine is over distracted, allowing for a large graft, there is an increased risk of subsidence into the endplate. If there is too little distraction, there is an increased risk of graft dislodgement or pseudoarthrosis. Generally, graft height is selected from preoperative measurements and observed distraction without knowing the intraoperative compressive load. This device was designed to give the surgeon an assessment of this applied load. Instrumentation of the device involved the application of strain gauges and the selection of materials that would survive standard autoclave sterilization. The device was calibrated, sterilized and once again calibrated to demonstrate its suitability for surgical use. Results demonstrate excellent linearity in the calibration, and no difference was detected in the pre- and post-sterilization calibrations.
Systems to facilitate reducing flashback/flame holding in combustion systems
Lacy, Benjamin Paul [Greer, SC; Kraemer, Gilbert Otto [Greer, SC; Varatharajan, Balachandar [Clifton Park, NY; Yilmaz, Ertan [Albany, NY; Zuo, Baifang [Simpsonville, SC
2012-02-21
A method for assembling a premixing injector is provided. The method includes providing a centerbody including a center axis and a radially outer surface, and providing an inlet flow conditioner. The inlet flow conditioner includes a radially outer wall, a radially inner wall, and an end wall coupled substantially perpendicularly between the outer wall and the inner wall. Each of the outer wall and the end wall include a plurality of openings defined therein. The outer wall, the inner wall, and the end wall define a first passage therebetween. The method also includes coupling the inlet flow conditioner to the centerbody such that the inlet flow conditioner substantially circumscribes the centerbody, such that the inner wall is substantially parallel to the centerbody outer surface, and such that a second passage is defined between the centerbody outer surface and the inner wall.
Dynamically Movable Exhausting Emc Sealing System
Barringer, Dennis R.; Seminaro, Edward J.; Toffler, Harold M.
2003-12-09
A docking apparatus for printed circuit boards including a cassette housing, having a housing base, a housing cover and a housing wall, wherein the housing base and the housing wall are disposed relative to each other so as to define a housing cavity for containing a printed circuit card and wherein the housing wall includes a cable opening disposed so as to be communicated with the housing cavity, a housing bezel, disposed relative to the cassette housing so as to be associated with the cable opening, the housing bezel includes an outer bezel having a first plurality of openings and an inner bezel having a second plurality of apertures, the inner bezel in electrical communication with the printed circuit card, wherein said housing bezel is removable, and an EMC gasket disposed between the outer and inner bezels of said housing bezel, the EMC gasket configured to provide a removable EMC seal proximate the cable opening while still allowing airflow through the first and second plurality of apertures having the EMC gasket therebetween. A docking apparatus for printed circuit boards including a cassette housing, having a housing base, a housing cover and a housing wall, wherein the housing base and the housing wall are disposed relative to each other so as to define a housing cavity for containing a printed circuit card and wherein the housing wall includes a cable opening disposed so as to be communicated with the housing cavity, a housing bezel, disposed relative to the cassette housing so as to be associated with the cable opening, the housing bezel includes an outer bezel having a first plurality of openings and an inner bezel having a second plurality of apertures, the inner bezel in electrical communication with the printed circuit card, wherein said housing bezel is removable, and an EMC gasket disposed between the outer and inner bezels of said housing bezel, the EMC gasket configured to provide a removable EMC seal proximate the cable opening while still allowing airflow through the first and second plurality of apertures having the EMC gasket therebetween.
Paredes, Igor; Panero, Irene; Cepeda, Santiago; Castaño-Leon, Ana M; Jimenez-Roldan, Luis; Perez-Nuñez, Ángel; Alén, Jose A; Lagares, Alfonso
2018-06-14
This study aimed to compare the accuracy of screw placement between open pedicle screw fixation and percutaneous pedicle screw fixation (MIS) for the treatment of thoracolumbar spine fractures (TSF). Forty-nine patients with acute TSF who were treated with transpedicular screw fixation from January 2013 to December 2016 were retrospectively reviewed. The patients were divided into Open and MIS groups. Laminectomy was performed in either group if needed. The accuracy of the screw placement, the evolution of the Cobb sagital angle postoperatively and at 12-month follow up and the neurological status were recorded. AO type of fracture and TLICS score were also recorded. Mean age was 42 years old. Mean TLICS score was 6,29 and 5,96 for open and MIS groups respectively. Twenty five MIS and 24 open surgeries were performed, and 350 (175 in each group) screws were inserted (7,14 per patient). Twenty-four and 13 screws were considered ̈out ̈ in the open and MIS groups respectively (Odds ratio 1,98. 0,97-4,03 p=0,056). The Cobb sagittal angle went from 13,3o to 4,5o and from 14,9o to 8,2o in the Open and MIS groups respectively (both p<0,0001). Loss of correction at 12-month follow up was 3,2o and 4,2o for the open and MIS groups respectively. No neurological worsening was observed. For the treatment of acute thoracolumbar fractures, the MIS technique seems to achieve similar results to the open technique in relation to neurological improvement and deformity correction, while placing the screws more accurately.
Motorized wellbore fishing tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, L.E.; Schasteen, T.
1989-08-15
This patent describes a fishing tool for retrieving an article located in a wellbore, wherein the fishing tool may be lowered into the wellbore by means connected to one end of the fishing tool. The fishing tool comprising: an elongated tubular body; an inner sleeve member secured to the body and extending axially within the body; a ball key disposed within each of the openings and movable at least partially into the bore in locking registration with a fishing head connected to the article; an outer sleeve member disposed in sleeved relationship around the inner sleeve member and movable axiallymore » between first and second positions with respect to the inner sleeve member. The outer sleeve member being operable to prevent, in the first position, radial outward movement of the ball keys out of the bore. The outer sleeve member including recess means formed thereon such that in the second position of the outer sleeve member the recess means is adjacent to the circumferentially spaced openings to allow limited radial outward movement of the ball keys; and means for axially moving the outer sleeve member between the first and second positions for engaging and releasing the fishing head with respect to the tool.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Angelin Jeba, K.; Latha, M. M., E-mail: lathaisaac@yahoo.com; Jain, Sudhir R.
2015-11-15
The nonlinear dynamics of intra- and inter-spine interaction models of alpha-helical proteins is investigated by proposing a Hamiltonian using the first quantized operators. Hamilton's equations of motion are derived, and the dynamics is studied by constructing the trajectories and phase space plots in both cases. The phase space plots display a chaotic behaviour in the dynamics, which opens questions about the relationship between the chaos and exciton-exciton and exciton-phonon interactions. This is verified by plotting the Lyapunov characteristic exponent curves.
Larson, Christopher M; Kelly, Bryan T; Stone, Rebecca M
2011-12-01
Femoroacetabular impingement is typically described as occurring due to a conflict between the femoral head-neck junction and acetabular rim. A prior case report described an open decompression of the anterior inferior iliac spine (AIIS) due to impingement against the proximal femur. AIIS impingement may be developmental or the result of a prior AIIS avulsion or pelvic osteotomy. We describe 3 representative cases with minimum 1-year follow-up treated with an arthroscopic AIIS decompression. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Sulfamethoxazole/Trimethoprim (Bactrim or Septra) and Pregnancy
... defects, neural tube defects (opening in the spine), cleft lip or palate (lip or roof of mouth do not form correctly), and urinary tract defects. Trimethoprim might decrease the ... bifida, oral clefts and heart defects. It is recommended that pregnant ...
Short communication: Traits unique to genus Homo within primates at the cervical spine (C2-C7).
Rios, Luis; Muñoz, Alexandra; Cardoso, Hugo; Pastor, Francisco
2014-05-01
From a comparative study of 222 human and 261 nonhuman primates complete cervical spines, two bony variants associated to the course of the vertebral artery are proposed as unique to genus Homo within primates. First, the opening of the foramen transversarium at C2, a trait present at low frequency in humans (3 to 5.6%). Second, the presence of a bipartite foramen transversarium in the cervical segment C3-C6, a trait that can be observed fully formed in human fetal skeletons, with a clear frequency pattern along the cervical spine (C3>C4>C5>C6
Spine surgery in geriatric patients: Sometimes unnecessary, too much, or too little
Epstein, Nancy E.
2011-01-01
Background: Although the frequency of spinal surgical procedures has been increasing, particularly in patients of age 65 and over (geriatric), multiple overlapping comorbidities increase their risk/complication rates. Nevertheless, sometimes these high-risk geriatric patients are considered for “unnecessary”, too much (instrumented fusions), or too little [minimally invasive surgery (MIS)] spine surgery. Methods: In a review of the literature and reanalysis of data from prior studies, attention was focused on the increasing number of operations offered to geriatric patients, their increased comorbidities, and the offers for “unnecessary” spine fusions, including both major open and MIS procedures. Results: In the literature, the frequency of spine operations, particularly instrumented fusions, has markedly increased in patients of age 65 and older. Specifically, in a 2010 report, a 28-fold increase in anterior discectomy and fusion was observed for geriatric patients. Geriatric patients with more comorbid factors, including diabetes, hypertension, coronary artery disease (prior procedures), depression, and obesity, experience higher postoperative complication rates and costs. Sometimes “unnecessary”, too much (instrumented fusions), and too little (MIS spine) surgeries were offered to geriatric patients, which increased the morbidity. One study observed a 10% complication rate for decompression alone (average age 76.4), a 40% complication rate for decompression/limited fusion (average age 70.4), and a 56% complication rate for full curve fusions (average age 62.5). Conclusions: Increasingly, spine operations in geriatric patients with multiple comorbidities are sometimes “unnecessary”, offer too much surgery (instrumentation), or too little surgery (MIS). PMID:22276241
Fourney, Daryl R; Dettori, Joseph R; Norvell, Daniel C; Dekutoski, Mark B
2010-04-20
Systematic review. The purpose of this review was to attempt to answer the following 2 clinical questions: (1) Does minimal access tubular assisted spine surgery (MAS) decrease the rate of complications in posterior thoracolumbar decompression and/or fusion surgery compared with traditional open techniques? (2) What strategies to reduce the risk of complications in MAS have been shown to be effective? The objective of minimal access spine surgery is to reduce damage to surrounding tissues while accomplishing the same goals as conventional surgery. Patient demand and marketing for MAS is driven by the perception of better outcomes, although the purported advantages remain unproven. Whether the risk of complications is affected by minimal access techniques is unknown. A systematic review of the English language literature was undertaken for articles published between 1990 and July 2009. Electronic databases and reference lists of key articles were searched to identify published studies that compared the rate of complications after MAS to a control group that underwent open surgery. Single-arm studies were excluded. Two independent reviewers assessed the strength of literature using GRADE criteria assessing quality, quantity, and consistency of results. Disagreements were resolved by consensus. From the 361 articles identified, 13 met a priori criteria and were included for review. All of the studies evaluated only lumbar spine surgery. The single large randomized study showed less favorable results for MAS discectomy, but no significant difference in complication rates. The quality of the other studies, particularly for fusion surgery, was low. Overall, the rates of reoperation, dural tear, cerebrospinal fluid leak, nerve injury, and infection occurred in similar proportions between MAS and open surgery. Blood loss was reduced in MAS fusion; however, the quality of those studies was very low. Operation time and hospital length of stay was variable across studies. There was no evidence to assess the effectiveness of strategies to reduce the risk of complications in MAS. Some data suggests that the rate of complications may decrease with experience. (1) Compared to open techniques, MAS does not decrease the rate of complications for posterior lumbar spinal decompression or fusion. (2) There is no evidence to assess the effectiveness of strategies to reduce the risk of MAS-related complications.
Yong, Mostyn R N O; Saifzadeh, Siamak; Askin, Geoffrey N; Labrom, Robert D; Hutmacher, Dietmar W; Adam, Clayton J
2014-01-01
A large animal model is required for the assessment of minimally invasive, tissue-engineering-based approaches to thoracic spine fusion, with relevance to deformity correction surgery for human adolescent idiopathic scoliosis. Here, we develop a novel open mini-thoracotomy approach in an ovine model of thoracic interbody fusion that allows the assessment of various fusion constructs, with a focus on novel, tissue-engineering-based interventions. The open mini-thoracotomy surgical approach was developed through a series of mock surgeries, and then applied in a live sheep study. Customized scaffolds were manufactured to conform with intervertebral disc space clearances that were required of the study. Six male Merino sheep aged 4-6 years and weighing 35-45 kg underwent the procedure mentioned earlier and were alloted a survival timeline of 6 months. Each sheep underwent a three-level discectomy (T6/7, T8/9, and T10/11) with a randomly allocated implantation of a different graft substitute at each of the following three levels: (1) polycaprolactone (PCL)-based scaffold plus 0.54 μg recombinant human bone morphogenetic protein-2 (rhBMP-2); (2) PCL-based scaffold alone; or (3) autograft. The sheep were closely monitored postoperatively for signs of pain (i.e., gait abnormalities/teeth gnawing/social isolation). Fusion assessments were conducted postsacrifice using computed tomography and hard-tissue histology. All scientific work was undertaken in accordance with the study protocol that was approved by the Institute's committee on animal research. All six sheep were successfully operated on and reached the allotted survival timeline, thereby demonstrating the feasibility of the surgical procedure and postoperative care. There were no significant complications and during the postoperative period, the animals did not exhibit marked signs of distress according to the previously described assessment criteria. Computed tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL-based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by a histological evaluation of the respective groups. This novel open mini-thoracotomy surgical approach to the ovine thoracic spine represents a safe surgical method that can reproducibly form the platform for research into various spine-tissue-engineered constructs and their fusion-promoting properties.
Slab edge insulating form system and methods
Lee, Brain E [Corral de Tierra, CA; Barsun, Stephan K [Davis, CA; Bourne, Richard C [Davis, CA; Hoeschele, Marc A [Davis, CA; Springer, David A [Winters, CA
2009-10-06
A method of forming an insulated concrete foundation is provided comprising constructing a foundation frame, the frame comprising an insulating form having an opening, inserting a pocket former into the opening; placing concrete inside the foundation frame; and removing the pocket former after the placed concrete has set, wherein the concrete forms a pocket in the placed concrete that is accessible through the opening. The method may further comprise sealing the opening by placing a sealing plug or sealing material in the opening. A system for forming an insulated concrete foundation is provided comprising a plurality of interconnected insulating forms, the insulating forms having a rigid outer member protecting and encasing an insulating material, and at least one gripping lip extending outwardly from the outer member to provide a pest barrier. At least one insulating form has an opening into which a removable pocket former is inserted. The system may also provide a tension anchor positioned in the pocket former and a tendon connected to the tension anchor.
Ohtsuka, Susumu; Tanaka, Hayato; Boxshall, Geoffrey A
2016-12-01
A new species of the cyclopinid genus Cyclopicina, C. toyoshioae sp. nov., was collected from the hyperbenthic layer off northern Kyushu Island, Japan; its description is based on two adult female specimens. This is the first record of the genus from the Indo-Pacific region. The new species can be distinguished from its two known congeners in: (1) the relatively short antennules which do not reach the posterior margin of the dorsal cephalothoracic shield; (2) the shape of seminal receptacles; (3) the segmentation and armature of the cephalothoracic appendages; (4) the shape of the basal protrusion between the rami of legs 1-4; (5) the presence of three outer spines on the third exopodal segment of leg 4; and (6) the presence or absence of outer setae on the free exopodal segment of leg 5. The genus Cyclopicina shows a wide but scattered distribution in hyperbenthic layers, from the continental shelves to deep-sea basins, in the northern hemisphere.
Inner shell radial pin geometry and mounting arrangement
Leach, David; Bergendahl, Peter Allen
2002-01-01
Circumferentially spaced arrays of support pins are disposed through access openings in an outer turbine shell and have projections received in recesses in forward and aft sections of an inner turbine shell supported from the outer shell. The projections have arcuate sides in a circumferential direction affording line contacts with the side walls of the recesses and are spaced from end faces of the recesses, enabling radial and axial expansion and contraction of the inner shell relative to the outer shell. All loads are taken up in a tangential direction by the outer shell with the support pins taking no radial loadings.
Turbine nozzle positioning system
Norton, Paul F.; Shaffer, James E.
1996-01-30
A nozzle guide vane assembly having a preestablished rate of thermal expansion is positioned in a gas turbine engine and being attached to conventional metallic components. The nozzle guide vane assembly includes an outer shroud having a mounting leg with an opening defined therein, a tip shoe ring having a mounting member with an opening defined therein, a nozzle support ring having a plurality of holes therein and a pin positioned in the corresponding opening in the outer shroud, opening in the tip shoe ring and the hole in the nozzle support ring. A rolling joint is provided between metallic components of the gas turbine engine and the nozzle guide vane assembly. The nozzle guide vane assembly is positioned radially about a central axis of the gas turbine engine and axially aligned with a combustor of the gas turbine engine.
Turbine nozzle positioning system
Norton, P.F.; Shaffer, J.E.
1996-01-30
A nozzle guide vane assembly having a preestablished rate of thermal expansion is positioned in a gas turbine engine and being attached to conventional metallic components. The nozzle guide vane assembly includes an outer shroud having a mounting leg with an opening defined therein, a tip shoe ring having a mounting member with an opening defined therein, a nozzle support ring having a plurality of holes therein and a pin positioned in the corresponding opening in the outer shroud, opening in the tip shoe ring and the hole in the nozzle support ring. A rolling joint is provided between metallic components of the gas turbine engine and the nozzle guide vane assembly. The nozzle guide vane assembly is positioned radially about a central axis of the gas turbine engine and axially aligned with a combustor of the gas turbine engine. 9 figs.
Open cycle ocean thermal energy conversion steam control and bypass system
Wittig, J. Michael; Jennings, Stephen J.
1980-01-01
Two sets of hinged control doors for regulating motive steam flow from an evaporator to a condenser alternatively through a set of turbine blades in a steam bypass around the turbine blades. The evaporator has a toroidal shaped casing situated about the turbine's vertical axis of rotation and an outlet opening therein for discharging motive steam into an annular steam flow path defined between the turbine's radially inner and outer casing structures. The turbine blades extend across the steam flow path intermediate the evaporator and condenser. The first set of control doors is arranged to prevent steam access to the upstream side of the turbine blades and the second set of control doors acts as a bypass around the blades so as to maintain equilibrium between the evaporator and condenser during non-rotation of the turbine. The first set of control doors preferably extend, when closed, between the evaporator casing and the turbine's outer casing and, when open, extend away from the axis of rotation. The second set of control doors preferably constitute a portion of the turbine's outer casing downstream from the blades when closed and extend, when open, toward the axis of rotation. The first and second sets of control doors are normally held in the open and closed positions respectively by locking pins which may be retracted upon detecting an abnormal operating condition respectively to permit their closing and opening and provide steam flow from the evaporator to the condenser.
Description of a new species of Microhyla from Bali, Indonesia (Amphibia, Anura).
Matsui, Masafumi; Hamidy, Amir; Eto, Koshiro
2013-01-01
We describe a microhylid frog from Bali, Indonesia as a new species, Microhyla orientalis sp. nov. It belongs to the M. achatina group and is close to M. mantheyi, M. malang, and M. borneensis. It is distinguished from its congeners by a combination of the following characters: small size (adult males about 16-17 mm in SVL); a faint vertebral stripe present; a black lateral stripe from behind eye to half length of trunk; snout rounded in profile; eyelid without supraciliary spines; first finger less than one-fifth of third; tips of three outer fingers weakly dilated, forming weak disks, dorsally with median longitudinal groove; outer palmar tubercle single; tibiotarsal articulation reaching up to center of eye; tips of toes distinctly dilated into disks, dorsally with median longitudinal groove; inner and outer metatarsal tubercles present; four or more phalanges on inner and outer sides of fourth toe, and three phalanges on inner side of fifth toe free of web; and tail of larva with a black marking at middle. The male advertisement call of the new species consists of a series of notes each lasts for 0.01-0.08 s and composed of 3-5 pulses with a dominant frequency of 3.2-3.6 kHz. Uncorrected sequence divergences between M. orientalis and all homologous 16S rRNA sequences available were > 6.6%. At present, the new species is known from rice fields between 435-815 m elevation in Wongaya Gede and Batukaru.
ERIC Educational Resources Information Center
Rees, Gareth
2007-01-01
In the UK, there remains an economy of "outer Britain" which has a higher representation of low-pay, low-skill jobs, and correspondingly, lower levels of economic growth than other parts of the country. The author discusses how the distinctive ideological complexions of Scottish and Welsh politics open the possibility of different…
Pumberger, Matthias; Hughes, Alexander P; Girardi, Federico P; Gogia, Jaspaul; Kotwal, Suhel Y; Thaler, Christoph; Sama, Andrew A
2012-12-01
Cadaveric study. The purpose of this study was to assess the influence of surgical experience on the efficiency of lumbar discectomy in open transforaminal lumbar interbody fusion. There is limited knowledge about the efficiency of discectomy among surgeons. As a first study, we are evaluating the effect of surgical experience on it. Manual and powered discectomies were randomized and performed by 3 attending spine surgeons and 2 clinical spine fellows. Each discectomy procedure was analyzed for the area of complete endplate preparation, total elapsed time, and number of instrument passes. The surface area of discectomy at each endplate was measured utilizing digital imaging and the appropriate software. For the purpose of the analysis, the superior and the inferior endplates were divided into ipsilateral and contralateral halves, and each half was further divided into ventral and dorsal quadrants. Each quadrant was analyzed in a blinded manner by 2 observers. A total of 40 discectomies were performed on 9 fresh-frozen cadaveric torsos between the levels T12 and S1. A powered discectomy device was used in levels 9 and 11 by the attendings. Manual discectomy was performed in 11 levels by the spine fellows and 9 by the spine attendings. No significant difference was observed between the spine fellows and spine attendings when the manual instruments were used (P = 0.924). However, the spine attending surgeon group had a significantly increased total area of discectomy compared with the fellows (P = 0.003). No significant difference was observed between the groups when instrument passes or the total elapsed time were compared either utilizing the manual or the powered technique. Our results demonstrate that a satisfactory discectomy may be performed by surgeons with relatively less surgical experience in the transforaminal approach using a powered discectomy device.
Spine–hip relations in patients with hip osteoarthritis
Rivière, Charles; Lazic, Stefan; Dagneaux, Louis; Van Der Straeten, Catherine; Cobb, Justin; Muirhead-Allwood, Sarah
2018-01-01
Patients with hip osteoarthritis often have an abnormal spine-hip relation (SHR), meaning the presence of a clinically deleterious spine-hip and/or hip-spine syndrome. Definition of the individual SHR is ideally done using the EOS® imaging system or, if not available, with conventional lumbopelvic lateral radiographs. By pre-operatively screening patients with abnormal SHR, it is possible to refine total hip replacement (THR) surgical planning, which may improve outcomes. An important component of the concept of kinematically aligned total hip arthroplasty (KA THA) consists of defining the optimal acetabular cup design and orientation based on the assessment of an individual’s SHR, and use of the transverse acetabular ligament to adjust the cup positioning. The Bordeaux classification might advance the understanding of SHR and hopefully help improve THR outcomes. Cite this article: EFORT Open Rev 2018;3:39-44. DOI: 10.1302/2058-5241.3.170020 PMID:29657844
Ehrlich, Herman; Elkin, Yury N; Artoukov, Alexandr A; Stonik, Valentin A; Safronov, Peter P; Bazhenov, Vasily V; Kurek, Denis V; Varlamov, Valery P; Born, René; Meissner, Heike; Richter, Gert
2011-06-01
Unique skeletal formations of marine invertebrates, including representatives of Echinodermata, have the unique potential to serve as templates for bio-inspired materials chemistry, biomimetics, and materials science. The sand dollar Scaphechinus mirabilis (Agassiz, 1983) is widely distributed in the northwest of the Pacific Ocean from southern Japan to the Aleutian Islands. This animal is the main source of naphtochinone-based substances. These compounds have recently drawn medical attention for their use as cardiological and ophthalmological drugs. Unfortunately, after extraction of the naphtochinones, the residual skeletons and spines of the sand dollars were usually discarded. Here, we report the first method for the preparation of nanostructurally organized spines of S. mirabilis, using a simple enzymatic and hydrogen peroxide-based treatment. Application of this method opens the way for development of non-wasteful environmentally clean technology of sand dollars as well-known industrial marine invertebrates.
Aghayev, Kamran; Vrionis, Frank D
2013-09-01
The main aim of this paper was to report reproducible method of lumbar spine access via a lateral retroperitoneal route. The authors conducted a retrospective analysis of the technical aspects and clinical outcomes of six patients who underwent lateral multilevel retroperitoneal interbody fusion with psoas muscle retraction technique. The main goal was to develop a simple and reproducible technique to avoid injury to the lumbar plexus. Six patients were operated at 15 levels using psoas muscle retraction technique. All patients reported improvement in back pain and radiculopathy after the surgery. The only procedure-related transient complication was weakness and pain on hip flexion that resolved by the first follow-up visit. Psoas retraction technique is a reliable technique for lateral access to the lumbar spine and may avoid some of the complications related to traditional minimally invasive transpsoas approach.
Thermal Energy Exchange Model and Water Loss of a Barrel Cactus, Ferocactus acanthodes1
Lewis, Donald A.; Nobel, Park S.
1977-01-01
The influences of various diurnal stomatal opening patterns, spines, and ribs on the stem surface temperature and water economy of a CAM succulent, the barrel cactus Ferocactus acanthodes, were examined using an energy budget model. To incorporate energy exchanges by shortwave and longwave irradiation, latent heat, conduction, and convection as well as the heat storage in the massive stem, the plant was subdivided into over 100 internal and external regions in the model. This enabled the average surface temperature to be predicted within 1 C of the measured temperature for both winter and summer days. Reducing the stem water vapor conductance from the values observed in the field to zero caused the average daily stem surface temperature to increase only 0.7 C for a winter day and 0.3 C for a summer day. Thus, latent heat loss does not substantially reduce stem temperature. Although the surface temperatures averaged 18 C warmer for the summer day than for the winter day for a plant 41 cm tall, the temperature dependence of stomatal opening caused the simulated nighttime water loss rates to be about the same for the 2 days. Spines moderated the amplitude of the diurnal temperature changes of the stem surface, since the daily variation was 17 C for the winter day and 25 C for the summer day with spines compared with 23 C and 41 C, respectively, in their simulated absence. Ribs reduced the daytime temperature rise by providing 54% more area for convective heat loss than for a smooth circumscribing surface. In a simulation where both spines and ribs were eliminated, the daytime average surface temperature rose by 5 C. PMID:16660148
Villafañe, Jorge H; Fernandez-de-Las-Peñas, Cesar; Pillastrini, Paolo
2012-12-01
The purpose of this case study is to present the findings of combining botulinum toxin type A (BoNT-A) and cervical spine manual therapy to address masseter muscle spasticity in a patient with Alzheimer-type dementia. A 78-year-old woman with bilateral spasticity of the masseteric regions for 2 years was referred for physiotherapy. She had trismus and bruxism, and could neither close nor open her mouth normally; thus, she was unable to be fed orally in a normal manner. The patient underwent combined treatment with BoNT-A and cervical spine manual therapy. A medical physician (neurologist) performed the BoNT-A injections into 2 points at the center of the lower third of the masseter muscle. A physical therapist performed manual therapy interventions targeted at the cervical spine. Manual therapy started the day after the BoNT-A injection and continued for 5 sessions per week for a total period of 2 weeks. Clinical outcomes were measured including spasticity (Modified Ashworth Scale), functionality (Barthel Index), and jaw opening. Outcomes were conducted at baseline, 2 weeks after treatment, and at 2-month follow-up session after finishing the treatment. The patient improved in all of the outcomes at the end of treatment, and these results were maintained during the follow-up. After treatment, the patient was able to feed with minimal caregiver dependency because oral feeding was possible. The patient in this study responded positively to a combination of BoNT-A and manual therapy, resulting in decreased masseter muscles spasticity and improved trismus and bruxism.
NASA Astrophysics Data System (ADS)
Karam, Gebran Nizar
1994-01-01
Thin walled cylindrical shell structures are widespread in nature: examples include plant stems, porcupine quills, and hedgehog spines. All have an outer shell of almost fully dense material supported by a low density, cellular core. In nature, all are loaded in combination of axial compression and bending: failure is typically by buckling. Natural structures are often optimized. Here we have analyzed the elastic buckling of a thin cylindrical shell supported by an elastic core to show that this structural configuration achieves significant weight saving over a hollow cylinder. The results of the analysis are compared with data from an extensive experimental program on uniaxial compression and four point bending tests on silicone rubber shells with and without compliant foam cores. The analysis describes the results of the mechanical tests well. Characterization of the microstructures of several natural tubular structures with foamlike cores (plant stems, quills, and spines) revealed them to be close to the optimal configurations predicted by the analytical model. Biomimicking of natural cylindrical shell structures and evolutionary design processes may offer the potential to increase the mechanical efficiency of engineering cylindrical shells.
Open-mouthed hybrid microcapsules with elevated enzyme loading and enhanced catalytic activity.
Shi, Jiafu; Zhang, Shaohua; Wang, Xiaoli; Jiang, Zhongyi
2014-10-25
Open-mouthed hybrid microcapsules (HMCs) are synthesized through a hard-templating method. When utilized for enzyme immobilization and enzymatic catalysis, the open-mouthed HMCs show high enzyme loading capability, enhanced catalytic activity and desirable recycling stability, due to their fully exposed outer and inner surfaces.
Survey of Hatching Spines of Bee Larvae Including Those of Apis mellifera (Hymenoptera: Apoidea).
Rozen, Jerome G; Shepard Smith, Corey; Cane, James H
2017-07-01
This article explores the occurrence of hatching spines among bee taxa and how these structures enable a larva on hatching to extricate itself from the egg chorion. These spines, arranged in a linear sequence along the sides of the first instar just dorsal to the spiracles, have been observed and recorded in certain groups of solitary and cleptoparasitic bee taxa. After eclosion, the first instar remains loosely covered by the egg chorion. The fact that this form of eclosion has been detected in five families (Table 1 identifies four of the families. The fifth family is the Andrenidae for which the presence of hatching spines in the Oxaeinae will soon be announced.) of bees invites speculation as to whether it is a fundamental characteristic of bees, or at least of solitary and some cleptoparasitic bees. The wide occurrence of these spines has prompted the authors to explore and discover their presence in the highly eusocial Apis mellifera L. Hatching spines were indeed discovered on first instar A. mellifera. The honey bee hatching process appears to differ in that the spines are displayed somewhat differently though still along the sides of the body, and the chorion, instead of splitting along the sides of the elongate egg, seems to quickly disintegrate from the emerging first instar in association with the nearly simultaneous removal of the serosa that covers and separates the first instar from the chorion. Unexpected observations of spherical bodies of various sizes perhaps containing dissolving enzymes being discharged from spiracular openings during hatching may shed future light on the process of how A. mellifera effects chorion removal during eclosion. Whereas hatching spines occur among many groups of bees, they appear to be entirely absent in the Nomadinae and parasitic Apinae, an indication of a different eclosion process. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America.
Solar heating and cooling diode module
Maloney, Timothy J.
1986-01-01
A high efficiency solar heating system comprising a plurality of hollow modular units each for receiving a thermal storage mass, the units being arranged in stacked relation in the exterior frame of a building, each of the units including a port for filling the unit with the mass, a collector region and a storage region, each region having inner and outer walls, the outer wall of the collector region being oriented for exposure to sunlight for heating the thermal storage mass; the storage region having an opening therein and the collector region having a corresponding opening, the openings being joined for communicating the thermal storage mass between the storage and collector regions by thermosiphoning; the collector region being disposed substantially below and in parallel relation to the storage region in the modular unit; and the inner wall of the collector region of each successive modular unit in the stacked relation extending over the outer wall of the storage region of the next lower modular unit in the stacked relation for reducing heat loss from the system. Various modifications and alternatives are disclosed for both heating and cooling applications.
Pyrometer mount for a closed-circuit thermal medium cooled gas turbine
Jones, Raymond Joseph; Kirkpatrick, Francis Lawrence; Burns, James Lee; Fulton, John Robert
2002-01-01
A steam-cooled second-stage nozzle segment has an outer band and an outer cover defining a plenum therebetween for receiving cooling steam for flow through the nozzles to the inner band and cover therefor and return flow through the nozzles. To measure the temperature of the buckets of the stage forwardly of the nozzle stage, a pyrometer boss is electron beam-welded in an opening through the outer band and TIG-welded to the outer cover plate. By machining a hole through the boss and seating a linearly extending tube in the boss, a line of sight between a pyrometer mounted on the turbine frame and the buckets is provided whereby the temperature of the buckets can be ascertained. The welding of the boss to the outer band and outer cover enables steam flow through the plenum without leakage, while providing a line of sight through the outer cover and outer band to measure bucket temperature.
Correlation between the outer flow and the turbulent production in a boundary layer
NASA Technical Reports Server (NTRS)
Cliff, W. C.; Sandborn, V. A.
1975-01-01
Space-time velocity correlation measurements between fluctuations occurring in the convoluting outer edge of a flat boundary layer with fluctuations occurring near the viscous subregion were made. The correlations indicate that information is propagated from the outer region to the inner region. The migration of turbulence away from the wall was previously studied in the open literature. The results presented here along with the migration results lend support to the limit cycle model for turbulence production.
Double window viewing chamber assembly
NASA Technical Reports Server (NTRS)
Keller, V. W. (Inventor); Owen, R. B. (Inventor); Elkins, B. R. (Inventor); White, W. T. (Inventor)
1986-01-01
A viewing chamber which permits observation of a sample retained therein includes a pair of double window assemblies mounted in opposed openings in the walls thereof so that a light beam can directly enter and exit from the chamber. A flexible mounting arrangement for the outer windows of the window assemblies enables the windows to be brought into proper alignment. An electrical heating arrangement prevents fogging of the outer windows whereas desiccated air in the volume between the outer and inner windows prevents fogging of the latter.
Ikeuchi, Hiroko; Ikuta, Ko
2016-09-01
In the last decade, posterior instrumented fusion using percutaneous pedicle screws (PPSs) had been growing in popularity, and its safety and good clinical results have been reported. However, there have been few previous reports of the accuracy of PPS placement compared with that of conventional open screw insertion in an institution. This study aimed to evaluate the accuracy of PPS placement compared with that of conventional open technique. One hundred patients were treated with posterior instrumented fusion of the thoracic and lumbar spine from April 2008 to July 2013. Four cases of revised instrumentation surgery were excluded. In this study, the pedicle screws inserted below Th7 were investigated, therefore, a total of 455 screws were enrolled. Two hundred and ninety-three pedicle screws were conventional open-inserted screws (O-group) and 162 screws were PPSs (P-group). We conducted a comparative study about the accuracy of placement between the two groups. Postoperative computed tomography scans were carried out to all patients, and the pedicle screw position was assessed according to a scoring system described by Zdichavsky et al. (Eur J Trauma 30:241-247, 2004; Eur J Trauma 30:234-240, 2004) and a classification described by Wiesner et al. (Spine 24:1599-1603, 1999). Based on Zdichavsky's scoring system, the number of grade Ia screws was 283 (96.6 %) in the O-group and 153 (94.4 %) in the P-group, whereas 5 screws (1.7 %) in the O-group and one screw (0.6 %) in the P-group were grade IIIa/IIIb. Meanwhile, the pedicle wall penetrations based on Wiesner classification were demonstrated in 20 screws (6.8 %) in the O-group, and 12 screws (7.4 %) in the P-group. No neurologic complications were observed and no screws had to be replaced in both groups. The PPSs could be ideally inserted without complications. There were no statistically significant differences about the accuracy between the conventional open insertion and PPS placement.
Lesiak, Adam; Zhu, Mingyan; Chen, Hao; Appleyard, Suzanne M.; Impey, Soren; Wayman, Gary A.
2014-01-01
Non–dioxin-like (NDL) polychlorinated biphenyls (PCBs) are widespread environmental contaminants linked to neuropsychological dysfunction in children. NDL PCBs increase spontaneous Ca2+ oscillations in neurons by stabilizing ryanodine receptor (RyR) calcium release channels in the open configuration, which results in CREB-dependent dendritic outgrowth. In this study, we address the question of whether activation of CREB by NDL PCBs also triggers dendritic spine formation. Nanomolar concentrations of PCB 95, a NDL congener with potent RyR activity, significantly increased spine density and the frequency of miniature EPSCs in primary dissociated rat hippocampal cultures coincident with upregulation of miR132. Inhibition of RyR, CREB, or miR132 as well as expression of a mutant p250GAP cDNA construct that is not suppressed by miR132 blocked PCB 95 effects on spines and miniature EPSCs. PCB 95 also induced spine formation via RyR- and miR132-dependent mechanisms in hippocampal slice cultures. These data demonstrate a novel mechanism of PCB developmental neurotoxicity whereby RyR sensitization modulates spine formation and synaptogenesis via CREB-mediated miR132 upregulation, which in turn suppresses the translation of p250GAP, a negative regulator of synaptogenesis. In light of recent evidence implicating miR132 dysregulation in Rett syndrome and schizophrenia, these findings identify NDL PCBs as potential environmental risk factors for neurodevelopmental disorders. PMID:24431430
30 CFR 291.110 - Who may MMS require to produce information?
Code of Federal Regulations, 2010 CFR
2010-07-01
... OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT... make a decision on whether open access or nondiscriminatory access was denied. (b) If you are a party...
30 CFR 291.110 - Who may MMS require to produce information?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER... believes is necessary to make a decision on whether open access or nondiscriminatory access was denied. (b...
All-reflective optical target illumination system with high numerical aperture
Thomas, Carlton E.; Sigler, Robert D.; Hoeger, John G.
1979-01-01
An all-reflective optical system for providing illumination of a target focal region at high numerical aperture from a pair of confluent collimated light beams. The collimated beams are each incident upon an associated concave eccentric pupil paraboloidal reflective surface, and thereby each focused through an opening in an associated outer ellipsoidal reflective surface onto a plane reflector. Each beam is reflected by its associated plane reflector onto the opposing concave surface of the outer ellipsoids to be focused through an opening in the plane surface onto an opposing inner concave ellipsoidal reflective surface, and thence onto the target region.
NEUTRONIC REACTOR SHIELD AND SPACER CONSTRUCTION
Wigner, E.P.; Ohlinger, L.A.
1958-11-18
Reactors of the heterogeneous, graphite moderated, fluid cooled type and shielding and spacing plugs for the coolant channels thereof are reported. In this design, the coolant passages extend horizontally through the moderator structure, accommodating the fuel elements in abutting end-to-end relationship, and have access openings through the outer shield at one face of the reactor to facilitate loading of the fuel elements. In the outer ends of the channels which extend through the shields are provided spacers and shielding plugs designed to offer minimal reslstance to coolant fluid flow while preventing emanation of harmful radiation through the access openings when closed between loadings.
Lin, Bon-Jour; Lin, Meng-Chi; Lin, Chin; Lee, Meei-Shyuan; Feng, Shao-Wei; Ju, Da-Tong; Ma, Hsin-I; Liu, Ming-Ying; Hueng, Dueng-Yuan
2015-10-01
Previous studies have identified the factors affecting the surgical outcome of cervical spondylotic myelopathy (CSM) following laminoplasty. Nonetheless, the effect of these factors remains controversial. It is unknown about the association between pre-operative cervical spinal cord morphology and post-operative imaging result following laminoplasty. The goal of this study is to analyze the impact of pre-operative cervical spinal cord morphology on post-operative imaging in patients with CSM. Twenty-six patients with CSM undergoing open-door laminoplasty were classified according to pre-operative cervical spine bony alignment and cervical spinal cord morphology, and the results were evaluated in terms of post-operative spinal cord posterior drift, and post-operative expansion of the antero-posterior dura diameter. By the result of study, pre-operative spinal cord morphology was an effective classification in predicting surgical outcome - patients with anterior convexity type, description of cervical spinal cord morphology, had more spinal cord posterior migration than those with neutral or posterior convexity type after open-door laminoplasty. Otherwise, the interesting finding was that cervical spine Cobb's angle had an impact on post-operative spinal cord posterior drift in patients with neutral or posterior convexity type spinal cord morphology - the degree of kyphosis was inversely proportional to the distance of post-operative spinal cord posterior drift, but not in the anterior convexity type. These findings supported that pre-operative cervical spinal cord morphology may be used as screening for patients undergoing laminoplasty. Patients having neutral or posterior convexity type spinal cord morphology accompanied with kyphotic deformity were not suitable candidates for laminoplasty. Copyright © 2015 Elsevier B.V. All rights reserved.
Asiedu, Gladys B; Lowndes, Bethany R; Huddleston, Paul M; Hallbeck, Susan
2016-01-07
The aim of this study was to define health care providers' perceptions toward prone patient positioning for spine surgery using the Jackson Table, which has not been hitherto explored. We analyzed open-ended questionnaire data and interviews conducted with the spine surgical team regarding the current process of spinal positioning/repositioning using the Jackson Table. Participants were asked to provide an open-ended explanation as to whether they think the current process of spinal positioning/repositioning is safe for the staff or patients. Follow-up qualitative interviews were conducted with 11 of the participants to gain an in-depth understanding of the challenges and safety issues related to prone patient positioning. Data analysis resulted in 6 main categories: general challenges with patient positioning, role-specific challenges, challenges with the Jackson Table and the "sandwich" mechanism, safety concerns for patients, safety concerns for the medical staff, and recommendations for best practices. This study is relevant to everyday practice for spinal surgical team members and advances our understanding of how surgical teams qualitatively view the current process of patient positioning for spinal surgery. Providers recommended best practices for using the Jackson Table, which can be achieved through standardized practice for transfer of patients, educational tools, and checklists for equipment before patient transfer and positioning. This research has identified several important practice opportunities for improving provider and patient safety in spine surgery.This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivitives 3.0 License, where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially. http://creativecommons.org/licenses/by-nc-nd/3.0.
Code of Federal Regulations, 2011 CFR
2011-07-01
... resolve an allegation that open and nondiscriminatory access was denied? 291.102 Section 291.102 Mineral... OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT... allegation concerning open and nondiscriminatory access by calling the toll-free MMS Hotline at 1-888-232...
Laser-induced activation of regeneration processes in spine disc cartilage
NASA Astrophysics Data System (ADS)
Sobol, Emil N.; Vorobjeva, Natalia N.; Sviridov, Alexander P.; Omelchenko, Alexander I.; Baskov, Andrey V.; Shekhter, Anatoliy B.; Baskov, Vladimir A.; Feldchtein, Felix I.; Kamensky, Vladislav A.; Kuranov, Roman V.
2000-05-01
The effect of laser radiation on the regeneration processes in spine disk cartilage has been studied in-vivo. We used rabbits as a model and a Holmium (2.09 micrometer) and an Erbium fiber (1.56 micrometer) lasers for irradiation the discs which were preliminary opened to remove annulus fibrosus and the nucleus pulposus of the intervertebral disc. The irradiated zone has been examined using an optical coherent tomography in one month after the operation and conventional histological technique in two months after the laser operation. It has been shown that laser radiation promotes the growth of the new cartilaginous tissue of fibrous and hyaline types.
Beutler, William J; Peppelman, Walter C; DiMarco, Luciano A
2013-02-15
Technique development to use the da Vince Robotic Surgical System for anterior lumbar interbody fusion at L5-S1 is detailed. A case report is also presented. To evaluate and develop the da Vinci robotic assisted laparoscopic anterior lumbar stand-alone interbody fusion procedure. Anterior lumbar interbody fusion is a common procedure associated with potential morbidity related to the surgical approach. The da Vinci robot provides intra-abdominal dissection and visualization advantages compared with the traditional open and laparoscopic approach. The surgical techniques for approach to the anterior lumbar spine using the da Vinci robot were developed and modified progressively beginning with operative models followed by placement of an interbody fusion cage in the living porcine model. Development continued to progress with placement of fusion cage in a human cadaver, completed first in the laboratory setting and then in the operating room. Finally, the first patient with fusion completed using the da Vinci robot-assisted approach is presented. The anterior transperitoneal approach to the lumbar spine is accomplished with enhanced visualization and dissection capability, with maintenance of pneumoperitoneum using the da Vinci robot. Blood loss is minimal. The visualization inside the disc space and surrounding structures was considered better than current open and laparoscopic techniques. The da Vinci robot Surgical System technique continues to develop and is now described for the transperitoneal approach to the anterior lumbar spine. 4.
Numerical simulations of the stratified oceanic bottom boundary layer
NASA Astrophysics Data System (ADS)
Taylor, John R.
Numerical simulations are used to consider several problems relevant to the turbulent oceanic bottom boundary layer. In the first study, stratified open channel flow is considered with thermal boundary conditions chosen to approximate a shallow sea. Specifically, a constant heat flux is applied at the free surface and the lower wall is assumed to be adiabatic. When the surface heat flux is strong, turbulent upwellings of low speed fluid from near the lower wall are inhibited by the stable stratification. Subsequent studies consider a stratified bottom Ekman layer over a non-sloping lower wall. The influence of the free surface is removed by using an open boundary condition at the top of the computational domain. Particular attention is paid to the influence of the outer layer stratification on the boundary layer structure. When the density field is initialized with a linear profile, a turbulent mixed layer forms near the wall, which is separated from the outer layer by a strongly stable pycnocline. It is found that the bottom stress is not strongly affected by the outer layer stratification. However, stratification reduces turbulent transport to the outer layer and strongly limits the boundary layer height. The mean shear at the top of the boundary layer is enhanced when the outer layer is stratified, and this shear is strong enough to cause intermittent instabilities above the pycnocline. Turbulence-generated internal gravity waves are observed in the outer layer with a relatively narrow frequency range. An explanation for frequency content of these waves is proposed, starting with an observed broad-banded turbulent spectrum and invoking linear viscous decay to explain the preferential damping of low and high frequency waves. During the course of this work, an open-source computational fluid dynamics code has been developed with a number of advanced features including scalar advection, subgrid-scale models for large-eddy simulation, and distributed memory parallelism.
Halovest treatment in traumatic cervical spine injury.
Razak, M; Basir, T; Hyzan, Y; Johari, Z
1998-09-01
This is a cross-sectional study on the use of halovest appliance in the Orthopaedic and Traumatology Department, Kuala Lumpur Hospital from June 1993 to September 1996. Fifty-three patients with cervical spine injuries were treated by halovest stabilization. Majority of cases was caused by motor-vehicle accident; others were fall from height at construction sites, fall at home, hit by falling object and assault. The injuries were Jefferson fracture of C1, odontoid fractures, hangman fractures, open spinous process fracture and fracture body of C2, and fracture, and fracture-dislocation of the lower cervical spines. Majority of patients had hospital stay less than 30 days. The use of the halovest ranges from 4 to 16 weeks and the healing rate was 96%. Two patients of lower cervical spine injury had redislocation and one of them was operated. There was one case of non-union of type II odontoid fracture and treated by posterior fusion. Other complications encountered during halovest treatment were minor. They were pin-site infection, pin-loosening, clamp loosening and neck pain or neck stiffness. This method of treatment enables patient to ambulate early and reduces hospital stay. We found that halovest is easy to apply, safe and tolerable to most of the patients.
Enders, Judith; Rief, Matthias; Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc
2013-01-01
The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34-37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. ClinicalTrials.gov NCT00715806.
Zimmermann, Elke; Asbach, Patrick; Diederichs, Gerd; Wetz, Christoph; Siebert, Eberhard; Wagner, Moritz; Hamm, Bernd; Dewey, Marc
2013-01-01
Background The purpose of the present study was to compare the image quality of spinal magnetic resonance (MR) imaging performed on a high-field horizontal open versus a short-bore MR scanner in a randomized controlled study setup. Methods Altogether, 93 (80% women, mean age 53) consecutive patients underwent spine imaging after random assignement to a 1-T horizontal open MR scanner with a vertical magnetic field or a 1.5-T short-bore MR scanner. This patient subset was part of a larger cohort. Image quality was assessed by determining qualitative parameters, signal-to-noise (SNR) and contrast-to-noise ratios (CNR), and quantitative contour sharpness. Results The image quality parameters were higher for short-bore MR imaging. Regarding all sequences, the relative differences were 39% for the mean overall qualitative image quality, 53% for the mean SNR values, and 34–37% for the quantitative contour sharpness (P<0.0001). The CNR values were also higher for images obtained with the short-bore MR scanner. No sequence was of very poor (nondiagnostic) image quality. Scanning times were significantly longer for examinations performed on the open MR scanner (mean: 32±22 min versus 20±9 min; P<0.0001). Conclusions In this randomized controlled comparison of spinal MR imaging with an open versus a short-bore scanner, short-bore MR imaging revealed considerably higher image quality with shorter scanning times. Trial Registration ClinicalTrials.gov NCT00715806 PMID:24391767
Synframe: a preliminary report.
Aebi, M; Steffen, T
2000-02-01
Both endoscopic lumbar spinal surgery and the non-standardized and unstable retractor systems for the lumbar spine presently on the market have disadvantages and limitations in relation to the minimally invasive surgical concept, which have been gradually recognized in the last few years. In an attempt to resolve some of these issues, we have developed a highly versatile retractor system, which allows access to and surgery at the lumbar, thoracic and even cervical spine. This retractor system - Synframe - is based on a ring concept allowing 360 degrees access to a surgical opening in anterior as well as posterior surgery. The ring is concentrically laid over the surgical opening for the approach and is used as a carrier for retractor arms, which are instrumented with either different sizes or types of blades and/or different sizes of Hohmann hooks. In posterior surgery, nerve root retractors can also be installed. This ring also functions as a carrier for fiberoptic illumination devices and different sizes of endoscopes, used to transmit the surgical procedure out of the depth of the surgical exposure for both teaching purposes and for the surgical team when it has no longer direct visual access to the procedure. The ring is stable, being fixed onto the operating table, allowing precise minimally open approaches and surgical procedures under direct vision with optimal illumination. This ring system also opens perspectives for an integrated minimally open surgical concept, where the ring may be used as a reference platform in computer-navigated surgery.
Arrom, Laia; Munné-Bosch, Sergi
2012-06-01
Sugars are generally used to extend the vase life of cut flowers. Such beneficial effects have been associated with an improvement of water relations and an increase in available energy for respiration by floral tissues. In this study we aimed at evaluating to what extent (i) endogenous levels of sugars in outer and inner tepals, androecium and gynoecium are altered during opening and senescence of lily flowers; (ii) sugar levels increase in various floral tissues after sucrose addition to the vase solution; and (iii) sucrose addition alters the hormonal balance of floral tissues. Results showed that endogenous glucose levels increased during flower opening and decreased during senescence in all floral organs, while sucrose levels increased in outer and inner tepals and the androecium during senescence. Sucrose treatment accelerated flower opening, and delayed senescence, but did not affect tepal abscission. Such effects appeared to be exerted through a specific increase in the endogenous levels of sucrose in the gynoecium and of glucose in all floral tissues. The hormonal balance was altered in the gynoecium as well as in other floral tissues. Aside from cytokinin and auxin increases in the gynoecium; cytokinins, gibberellins, abscisic acid and salicylic acid levels increased in the androecium, while abscisic acid decreased in outer tepals. It is concluded that sucrose addition to the vase solution exerts an effect on flower opening and senescence by, among other factors, altering the hormonal balance of several floral tissues. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Han, Zhou; Anderson, David W.
2012-01-01
Purpose. Prominin-1 expresses in rod and cone photoreceptors. Mutations in the prominin-1 gene cause retinal degeneration in humans. In this study, the authors investigated the expression and subcellular localization of xlProminin-1 protein, the Xenopus laevis ortholog of prominin-1, in rod and cone photoreceptors of this frog. Methods. Antibodies specific for xlProminin-1 were generated. Immunoblotting was used to study the expression and posttranslational processing of xlProminin-1 protein. Immunocytochemical light and electron microscopy and transgenesis were used to study the subcellular distribution of xlProminin-1. Results. xlProminin-1 is expressed and is subject to posttranslational proteolytic processing in the retina, brain, and kidney. xlProminin-1 is differently expressed and localized in outer segments of rod and cone photoreceptors of X. laevis. Antibodies specific for the N or C termini of xlProminin-1 labeled the open rims of lamellae of cone outer segments (COS) and the open lamellae at the base of rod outer segments (ROS). By contrast, anti–peripherin-2/rds antibody, Xper5A11, labeled the closed rims of cone lamellae adjacent to the ciliary axoneme and the rims of the closed ROS disks. The extent of labeling of the basal ROS by anti–xlProminin-1 antibodies varied with the light cycle in this frog. The entire ROS was also faintly labeled by both antibodies, a result that contrasts with the current notion that prominin-1 localizes only to the basal ROS. Conclusions. These findings suggest that xlProminin-1 may serve as an anti–fusogenic factor in the regulation of disk morphogenesis and may help to maintain the open lamellar structure of basal ROS and COS disks in X. laevis photoreceptors. PMID:22076989
Gas turbine row #1 steam cooled vane
Cunha, Frank J.
2000-01-01
A design for a vane segment having a closed-loop steam cooling system is provided. The vane segment comprises an outer shroud, an inner shroud and an airfoil, each component having a target surface on the inside surface of its walls. A plurality of rectangular waffle structures are provided on the target surface to enhance heat transfer between each component and cooling steam. Channel systems are provided in the shrouds to improve the flow of steam through the shrouds. Insert legs located in cavities in the airfoil are also provided. Each insert leg comprises outer channels located on a perimeter of the leg, each outer channel having an outer wall and impingement holes on the outer wall for producing impingement jets of cooling steam to contact the airfoil's target surface. Each insert leg further comprises a plurality of substantially rectangular-shaped ribs located on the outer wall and a plurality of openings located between outer channels of the leg to minimize cross flow degradation.
30 CFR 291.104 - Who may file a complaint or a third-party brief?
Code of Federal Regulations, 2010 CFR
2010-07-01
... APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS... subpart if you are a shipper and you believe that you have been denied open and nondiscriminatory access...
Cantarella, Daniele; Dominguez-Mompell, Ramon; Mallya, Sanjay M; Moschik, Christoph; Pan, Hsin Chuan; Miller, Joseph; Moon, Won
2017-11-01
Mini-implant-assisted rapid palatal expansion (MARPE) appliances have been developed with the aim to enhance the orthopedic effect induced by rapid maxillary expansion (RME). Maxillary Skeletal Expander (MSE) is a particular type of MARPE appliance characterized by the presence of four mini-implants positioned in the posterior part of the palate with bi-cortical engagement. The aim of the present study is to evaluate the MSE effects on the midpalatal and pterygopalatine sutures in late adolescents, using high-resolution CBCT. Specific aims are to define the magnitude and sagittal parallelism of midpalatal suture opening, to measure the extent of transverse asymmetry of split, and to illustrate the possibility of splitting the pterygopalatine suture. Fifteen subjects (mean age of 17.2 years; range, 13.9-26.2 years) were treated with MSE. Pre- and post-treatment CBCT exams were taken and superimposed. A novel methodology based on three new reference planes was utilized to analyze the sutural changes. Parameters were compared from pre- to post-treatment and between genders non-parametrically using the Wilcoxon sign rank test. For the frequency of openings in the lower part of the pterygopalatine suture, the Fisher's exact test was used. Regarding the magnitude of midpalatal suture opening, the split at anterior nasal spine (ANS) and at posterior nasal spine (PNS) was 4.8 and 4.3 mm, respectively. The amount of split at PNS was 90% of that at ANS, showing that the opening of the midpalatal suture was almost perfectly parallel antero-posteriorly. On average, one half of the anterior nasal spine (ANS) moved more than the contralateral one by 1.1 mm. Openings between the lateral and medial plates of the pterygoid process were detectable in 53% of the sutures (P < 0.05). No significant differences were found in the magnitude and frequency of suture opening between males and females. Correlation between age and suture opening was negligible (R 2 range, 0.3-4.2%). Midpalatal suture was successfully split by MSE in late adolescents, and the opening was almost perfectly parallel in a sagittal direction. Regarding the extent of transverse asymmetry of the split, on average one half of ANS moved more than the contralateral one by 1.1 mm. Pterygopalatine suture was split in its lower region by MSE, as the pyramidal process was pulled out from the pterygoid process. Patient gender and age had a negligible influence on suture opening for the age group considered in the study.
Inductively coupled plasma torch with laminar flow cooling
Rayson, Gary D.; Shen, Yang
1991-04-30
An improved inductively coupled gas plasma torch. The torch includes inner and outer quartz sleeves and tubular insert snugly fitted between the sleeves. The insert includes outwardly opening longitudinal channels. Gas flowing through the channels of the insert emerges in a laminar flow along the inside surface of the outer sleeve, in the zone of plasma heating. The laminar flow cools the outer sleeve and enables the torch to operate at lower electrical power and gas consumption levels additionally, the laminar flow reduces noise levels in spectroscopic measurements of the gaseous plasma.
Spherical bearing. [to reduce vibration effects
NASA Technical Reports Server (NTRS)
Myers, W. N.; Hein, L. A. (Inventor)
1978-01-01
A spherical bearing including an inner ball with an opening for receiving a shaft and a spherical outer surface is described. Features of the bearing include: (1) a circular outer race including a plurality of circumferentially spaced sections extending around the inner ball for snugly receiving the inner ball; and (2) a groove extending circumferentially around the race producing a thin wall portion which permits the opposed side portions to flex relative to the ball for maximizing the physical contact between the inner surface of the race and the spherical outer surface of the ball.
Code of Federal Regulations, 2011 CFR
2011-07-01
... decision on whether a grantee or transporter has provided open and nondiscriminatory access? 291.112..., DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER... grantee or transporter has provided open and nondiscriminatory access? MMS will begin processing a...
Izatt, Reed M.; Christensen, James J.; Hawkins, Richard T.
1984-01-01
A process of recovering cesium ions from mixtures of ions containing them and other ions, e.g., a solution of nuclear waste materials, which comprises establishing a separate source phase containing such a mixture of ions, establishing a separate recipient phase, establishing a liquid membrane phase in interfacial contact with said source and recipient phases, said membrane phase containing a ligand, preferably a selected calixarene as depicted in the drawing, maintaining said interfacial contact for a period of time long enough to transport by said ligand a substantial portion of the cesium ion from the source phase to the recipient phase, and recovering the cesium ion from the recipient phase. The separation of the source and recipient phases may be by the membrane phase only, e.g., where these aqueous phases are emulsified as dispersed phases in a continuous membrane phase, or may include a physical barrier as well, e.g., an open-top outer container with an inner open-ended container of smaller cross-section mounted in the outer container with its open bottom end spaced from and above the closed bottom of the outer container so that the membrane phase may fill the outer container to a level above the bottom of the inner container and have floating on its upper surface a source phase and a recipient phase separated by the wall of the inner container as a physical barrier. A preferred solvent for the ligand is a mixture of methylene chloride and carbon tetrachloride.
Open-Section Composite Structural Elements
NASA Technical Reports Server (NTRS)
Loftin, T. A.; Smith, C. A.; Raheb, S. J.; Nowitzky, A. M.
1991-01-01
Report describes investigation of manufacture and mechanical properties of graphite-fiber/aluminum-matrix open-section structural elements; e.g., channels and angle bars. Conducted with view toward using such elements to build lightweight, thermally stable truss structures in outer space. Other applications transport to, and assembly at, remote or otherwise uninviting locations. Advantages include shapes permitting high packing density during shipment, convenient paths for routing tubes, hoses, and cables; accessibility of both inner and outer surfaces for repair; and ease of attachment of additional hardware. Easier and require less equipment to fabricate, and more amenable to automated fabrication and assembly at remote site. Disadvantages, not as resistant to some kinds of deformation under load.
Xu, Yongbin; Moeller, Arne; Jun, So-Young; Le, Minho; Yoon, Bo-Young; Kim, Jin-Sik; Lee, Kangseok; Ha, Nam-Chul
2012-01-01
Gram-negative bacteria are capable of expelling diverse xenobiotic substances from within the cell by use of three-component efflux pumps in which the energy-activated inner membrane transporter is connected to the outer membrane channel protein via the membrane fusion protein. In this work, we describe the crystal structure of the membrane fusion protein MexA from the Pseudomonas aeruginosa MexAB-OprM pump in the hexameric ring arrangement. Electron microscopy study on the chimeric complex of MexA and the outer membrane protein OprM reveals that MexA makes a tip-to-tip interaction with OprM, which suggests a docking model for MexA and OprM. This docking model agrees well with genetic results and depicts detailed interactions. Opening of the OprM channel is accompanied by the simultaneous exposure of a protein structure resembling a six-bladed cogwheel, which intermeshes with the complementary cogwheel structure in the MexA hexamer. Taken together, we suggest an assembly and channel opening model for the MexAB-OprM pump. This study provides a better understanding of multidrug resistance in Gram-negative bacteria. PMID:22308040
A prospective evaluation of open face masks for head and neck radiation therapy.
Wiant, David; Squire, Sarah; Liu, Han; Maurer, Jacqueline; Lane Hayes, T; Sintay, Benjamin
Head and neck (HN) radiation therapy patients are typically immobilized with closed thermoplastic masks that cover the face and may cause discomfort. In this work, we examine the use of open masks for HN radiation therapy. Fifty HN patients were prospectively randomized into 2 groups (25 closed masks, 25 open masks). The open-mask group was monitored with surface imaging to evaluate intrafraction motion. Both groups underwent daily volumetric imaging. All daily images were rigidly registered to their respective planning images to evaluate spinal canal and mandible position as a check for interfraction posture change. Posture changes were determined by the amount the spinal canal and mandible contours from the planning images had to be expanded to cover the structures on each daily image set. The vector length (VL) of the intrafraction linear translations, spine, and mandible positions for each open-mask patient were checked for correlation with fraction number using the Pearson r value. All patients were given a weekly survey ranking anxiety and claustrophobia from 0 to 10 (0 = no issue, 10 = extreme issue). The mean VL for all open-mask patients was 0.9 ± 0.5 mm (1 standard deviation). Only 1 patient showed significant correlation between VL and fraction number. The mean contour expansions to cover the spine and mandible were 1.5 ± 0.9 mm and 1.8 ± 1.3 mm for the closed-mask group, and 1.6 ± 0.8 mm and 1.8 ± 1.1 mm for the open-mask group. Both groups showed similar behavior relative to fraction number. The mean anxiety and claustrophobia scores were 1.63 and 1.44 for the closed-mask group, and 0.81 and 0.63 for the open-mask group. The groups were not significantly different. Open masks provide comparable immobilization and posture preservation to closed masks for HN radiation therapy. Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
De Rubeis, Silvia; Pasciuto, Emanuela; Li, Ka Wan; Fernández, Esperanza; Di Marino, Daniele; Buzzi, Andrea; Ostroff, Linnaea E.; Klann, Eric; Zwartkruis, Fried J.T.; Komiyama, Noboru H.; Grant, Seth G.N.; Poujol, Christel; Choquet, Daniel; Achsel, Tilmann; Posthuma, Danielle; Smit, August B.; Bagni, Claudia
2013-01-01
Summary The CYFIP1/SRA1 gene is located in a chromosomal region linked to various neurological disorders, including intellectual disability, autism, and schizophrenia. CYFIP1 plays a dual role in two apparently unrelated processes, inhibiting local protein synthesis and favoring actin remodeling. Here, we show that brain-derived neurotrophic factor (BDNF)-driven synaptic signaling releases CYFIP1 from the translational inhibitory complex, triggering translation of target mRNAs and shifting CYFIP1 into the WAVE regulatory complex. Active Rac1 alters the CYFIP1 conformation, as demonstrated by intramolecular FRET, and is key in changing the equilibrium of the two complexes. CYFIP1 thus orchestrates the two molecular cascades, protein translation and actin polymerization, each of which is necessary for correct spine morphology in neurons. The CYFIP1 interactome reveals many interactors associated with brain disorders, opening new perspectives to define regulatory pathways shared by neurological disabilities characterized by spine dysmorphogenesis. PMID:24050404
Papp, Gergely; Felisaz, Franck; Sorez, Clement; Lopez-Marrero, Marcos; Janocha, Robert; Manjasetty, Babu; Gobbo, Alexandre; Belrhali, Hassan; Bowler, Matthew W; Cipriani, Florent
2017-10-01
Automated sample changers are now standard equipment for modern macromolecular crystallography synchrotron beamlines. Nevertheless, most are only compatible with a single type of sample holder and puck. Recent work aimed at reducing sample-handling efforts and crystal-alignment times at beamlines has resulted in a new generation of compact and precise sample holders for cryocrystallography: miniSPINE and NewPin [see the companion paper by Papp et al. (2017, Acta Cryst., D73, 829-840)]. With full data collection now possible within seconds at most advanced beamlines, and future fourth-generation synchrotron sources promising to extract data in a few tens of milliseconds, the time taken to mount and centre a sample is rate-limiting. In this context, a versatile and fast sample changer, FlexED8, has been developed that is compatible with the highly successful SPINE sample holder and with the miniSPINE and NewPin sample holders. Based on a six-axis industrial robot, FlexED8 is equipped with a tool changer and includes a novel open sample-storage dewar with a built-in ice-filtering system. With seven versatile puck slots, it can hold up to 112 SPINE sample holders in uni-pucks, or 252 miniSPINE or NewPin sample holders, with 36 samples per puck. Additionally, a double gripper, compatible with the SPINE sample holders and uni-pucks, allows a reduction in the sample-exchange time from 40 s, the typical time with a standard single gripper, to less than 5 s. Computer vision-based sample-transfer monitoring, sophisticated error handling and automatic error-recovery procedures ensure high reliability. The FlexED8 sample changer has been successfully tested under real conditions on a beamline.
Annual Research Progress Report. 1 October 1977-30 September 1978.
1978-09-30
requiring craniotomy , one open skull frac- ture, one cervical spine fracture, two quadraplegic patients and seven patients with an acute brain...attempt of aspiration is made. Although the blood is available by gravity drainage , this is not ideal for short collections periods. Further work on the
Recirculating electric air filter
Bergman, Werner
1986-01-01
An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.
Recirculating electric air filter
Bergman, W.
1985-01-09
An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.
NASA Astrophysics Data System (ADS)
Handhika, T.; Bustamam, A.; Ernastuti, Kerami, D.
2017-07-01
Multi-thread programming using OpenMP on the shared-memory architecture with hyperthreading technology allows the resource to be accessed by multiple processors simultaneously. Each processor can execute more than one thread for a certain period of time. However, its speedup depends on the ability of the processor to execute threads in limited quantities, especially the sequential algorithm which contains a nested loop. The number of the outer loop iterations is greater than the maximum number of threads that can be executed by a processor. The thread distribution technique that had been found previously only be applied by the high-level programmer. This paper generates a parallelization procedure for low-level programmer in dealing with 2-level nested loop problems with the maximum number of threads that can be executed by a processor is smaller than the number of the outer loop iterations. Data preprocessing which is related to the number of the outer loop and the inner loop iterations, the computational time required to execute each iteration and the maximum number of threads that can be executed by a processor are used as a strategy to determine which parallel region that will produce optimal speedup.
Exploring the Milky Way Disk Abundance Transition Zone Rgc 10 kpc with Open Clusters
NASA Astrophysics Data System (ADS)
Jacobson, Heather R.; Friel, E.; Pilachowski, C.
2009-01-01
Recent studies of the radial chemical abundance distribution among stellar populations in the Galactic disk have shown a change in the abundance trend at galactocentric distance Rgc 10 kpc, as first noted by Twarog et al. (1997). Here the gradient in [Fe/H] with distance appears to vanish, with abundances of stars at greater distances dropping to [Fe/H] -0.3, independent of galactocentric distance. Much is still unknown about the exact nature of the transition from inner to outer disk, and it is still uncertain if the outer disk has had a distinct evolutionary history from that of the inner disk. While current chemical evolution models can well match the outer disk abundances (Cescutti et al. 2007), abundances of many more stars at Rgc 9-12 kpc must be determined to better characterize the nature of the transition from inner to outer disk. We have initiated a survey of abundances of 20 open clusters in this region using spectroscopy obtained with the WIYN, KPNO 4m, CTIO 4m and Hobby-Eberly telescopes. Chemical abundances are determined for Fe, O, Na, and alpha-elements, among others. Results for the survey to date are presented here.
Schneider, William R.
1989-01-01
Methods and apparatus for removing a pollutant such as dust (33) from a fluid stream (34). A nested array of fibers (35) is provided in a substantially annular container (36) having openings in its inner (32) and outer (31) cylindrical sides of such size as to retain the fibers (35) within the container while permitting fluid (34) to pass through easily, and the pollutant-containing fluid stream (34) is passed through at least a substantial portion of the container (36) from a region (37) outside the outer side (31) to a region (38) inside the inner side (32). Thus a substantial fraction of the pollutant (33) is separated from the fluid stream (34) in a portion of the nested array (35) generally nearer to the outer side (31) of the container (36) than to the inner side (31). From time to time the container (36) is rotated about its axis to remove a substantial fraction of the separated pollutant (33) from the nested array (35), by tumbling action and by the force of gravity, through the openings in the outer side (31) of the container (36). To assist in this removal, purging fluid (41) may be directed back through the container (36) from the inner side (32) during the tumbling.
Gutiérrez-Aguirre, Martha Angélica; Mercado-Salas, Nancy Fabiola; Cervantes-Martínez, Adrián
2013-01-01
Abstract Two new species of the freshwater cyclopoid genera Eucyclops are described, Eucyclops tziscao sp. n. and E. angeli sp. n. Both species belong to the serrulatus-group defined by morphological features such as: the presence of distal spinules or hair-like setae (groups N1 and N2) on frontal surface of antennal basis; the fourth leg coxa with a strong inner spine that bears dense setules on inner side, yet proximally naked (large gap) on outer side; and a 12-segmented antennule with smooth hyaline membrane on the three distalmost segments. Eucyclops tziscao sp. n. is morphologically similar to E. bondi and E. conrowae but differs from these species in having a unique combination of characters, including a caudal ramus 4.05±0.25 times as long as wide, lateral seta of Enp3P4 modified as a strong, sclerotized blunt seta, coxal spine of fourth leg with inner spinule-like setules distally, and sixth leg of males bearing a strong and long inner spine 2.3 times longer than median seta. Eucyclops angeli sp. n. can be distinguished by an unique combination of morphological features: the short caudal ramus; the long spine on the sixth antennular segment of A1; the presence of one additional group of spinules (N12’) on the caudal surface of A2; the presence of long setae in females, or short spinules in males on the lateral margin of fourth prosomite; the strong ornamentation of the intercoxal sclerite of P4, specially group I modified as long denticles; the distal modified setae of Exp3P3 and Exp3P4 in females and males; and the short lateral seta of P5. Finally, we report on a new record of E. festivus in México, and add data on morphology of the species. PMID:24294085
Inner and Outer Recursive Neural Networks for Chemoinformatics Applications.
Urban, Gregor; Subrahmanya, Niranjan; Baldi, Pierre
2018-02-26
Deep learning methods applied to problems in chemoinformatics often require the use of recursive neural networks to handle data with graphical structure and variable size. We present a useful classification of recursive neural network approaches into two classes, the inner and outer approach. The inner approach uses recursion inside the underlying graph, to essentially "crawl" the edges of the graph, while the outer approach uses recursion outside the underlying graph, to aggregate information over progressively longer distances in an orthogonal direction. We illustrate the inner and outer approaches on several examples. More importantly, we provide open-source implementations [available at www.github.com/Chemoinformatics/InnerOuterRNN and cdb.ics.uci.edu ] for both approaches in Tensorflow which can be used in combination with training data to produce efficient models for predicting the physical, chemical, and biological properties of small molecules.
Photo-switchable tweezers illuminate pore-opening motions of an ATP-gated P2X ion channel
Habermacher, Chloé; Martz, Adeline; Calimet, Nicolas; Lemoine, Damien; Peverini, Laurie; Specht, Alexandre; Cecchini, Marco; Grutter, Thomas
2016-01-01
P2X receptors function by opening a transmembrane pore in response to extracellular ATP. Recent crystal structures solved in apo and ATP-bound states revealed molecular motions of the extracellular domain following agonist binding. However, the mechanism of pore opening still remains controversial. Here we use photo-switchable cross-linkers as ‘molecular tweezers’ to monitor a series of inter-residue distances in the transmembrane domain of the P2X2 receptor during activation. These experimentally based structural constraints combined with computational studies provide high-resolution models of the channel in the open and closed states. We show that the extent of the outer pore expansion is significantly reduced compared to the ATP-bound structure. Our data further reveal that the inner and outer ends of adjacent pore-lining helices come closer during opening, likely through a hinge-bending motion. These results provide new insight into the gating mechanism of P2X receptors and establish a versatile strategy applicable to other membrane proteins. DOI: http://dx.doi.org/10.7554/eLife.11050.001 PMID:26808983
Asiedu, Gladys B; Lowndes, Bethany R; Huddleston, Paul M; Hallbeck, Susan
2018-03-01
The aim of this study was to define health care providers' perceptions toward prone patient positioning for spine surgery using the Jackson Table, which has not been hitherto explored. We analyzed open-ended questionnaire data and interviews conducted with the spine surgical team regarding the current process of spinal positioning/repositioning using the Jackson Table. Participants were asked to provide an open-ended explanation as to whether they think the current process of spinal positioning/repositioning is safe for the staff or patients. Follow-up qualitative interviews were conducted with 11 of the participants to gain an in-depth understanding of the challenges and safety issues related to prone patient positioning. Data analysis resulted in 6 main categories: general challenges with patient positioning, role-specific challenges, challenges with the Jackson Table and the "sandwich" mechanism, safety concerns for patients, safety concerns for the medical staff, and recommendations for best practices. This study is relevant to everyday practice for spinal surgical team members and advances our understanding of how surgical teams qualitatively view the current process of patient positioning for spinal surgery. Providers recommended best practices for using the Jackson Table, which can be achieved through standardized practice for transfer of patients, educational tools, and checklists for equipment before patient transfer and positioning. This research has identified several important practice opportunities for improving provider and patient safety in spine surgery.
Zemmar, Ajmal; Chen, Chia-Chien; Weinmann, Oliver; Kast, Brigitt; Vajda, Flora; Bozeman, James; Isaad, Noel; Zuo, Yi; Schwab, Martin E
2018-06-01
Nogo-A has been well described as a myelin-associated inhibitor of neurite outgrowth and functional neuroregeneration after central nervous system (CNS) injury. Recently, a new role of Nogo-A has been identified as a negative regulator of synaptic plasticity in the uninjured adult CNS. Nogo-A is present in neurons and oligodendrocytes. However, it is yet unclear which of these two pools regulate synaptic plasticity. To address this question we used newly generated mouse lines in which Nogo-A is specifically knocked out in (1) oligodendrocytes (oligoNogo-A KO) or (2) neurons (neuroNogo-A KO). We show that both oligodendrocyte- and neuron-specific Nogo-A KO mice have enhanced dendritic branching and spine densities in layer 2/3 cortical pyramidal neurons. These effects are compartmentalized: neuronal Nogo-A affects proximal dendrites whereas oligodendrocytic Nogo-A affects distal regions. Finally, we used two-photon laser scanning microscopy to measure the spine turnover rate of adult mouse motor cortex layer 5 cells and find that both Nogo-A KO mouse lines show enhanced spine remodeling after 4 days. Our results suggest relevant control functions of glial as well as neuronal Nogo-A for synaptic plasticity and open new possibilities for more selective and targeted plasticity enhancing strategies.
Lean-rich axial stage combustion in a can-annular gas turbine engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laster, Walter R.; Szedlacsek, Peter
2016-06-14
An apparatus and method for lean/rich combustion in a gas turbine engine (10), which includes a combustor (12), a transition (14) and a combustor extender (16) that is positioned between the combustor (12) and the transition (14) to connect the combustor (12) to the transition (14). Openings (18) are formed along an outer surface (20) of the combustor extender (16). The gas turbine (10) also includes a fuel manifold (28) to extend along the outer surface (20) of the combustor extender (16), with fuel nozzles (30) to align with the respective openings (18). A method (200) for axial stage combustionmore » in the gas turbine engine (10) is also presented.« less
Cranial airways and the integration between the inner and outer facial skeleton in humans.
Bastir, Markus; Rosas, Antonio
2013-10-01
The cranial airways are in the center of the human face. Therefore variation in the size and shape of these central craniofacial structures could have important consequences for the surrounding midfacial morphology during development and evolution. Yet such interactions are unclear because one school of thought, based on experimental and developmental evidence, suggests a relative independence (modularity) of these two facial compartments, whereas another one assumes tight morphological integration. This study uses geometric morphometrics of modern humans (N = 263) and 40 three-dimensional-landmarks of the skeletal nasopharynx and nasal cavity and outer midfacial skeleton to analyze these questions in terms of modularity. The sizes of all facial compartments were all strongly correlated. Shape integration was high between the cranial airways and the outer midfacial skeleton and between the latter and the anterior airway openings (skeletal regions close to and including piriform aperture). However, no shape integration was detected between outer midface and posterior airway openings (nasopharynx and choanae). Similarly, no integration was detected between posterior and anterior airway openings. This may reflect functional modularization of nasal cavity compartments related to respiratory physiology and differential developmental interactions with the face. Airway size likely relates to the energetics of the organism, whereas airways shape might be more indicative of respiratory physiology and climate. Although this hypothesis should be addressed in future steps, here we suggest that selection on morphofunctional characteristics of the cranial airways could have cascading effects for the variation, development, and evolution of the human face. Copyright © 2013 Wiley Periodicals, Inc.
Crystal Structure of the Cohesin Gatekeeper Pds5 and in Complex with Kleisin Scc1.
Lee, Byung-Gil; Roig, Maurici B; Jansma, Marijke; Petela, Naomi; Metson, Jean; Nasmyth, Kim; Löwe, Jan
2016-03-08
Sister chromatid cohesion is mediated by cohesin, whose Smc1, Smc3, and kleisin (Scc1) subunits form a ring structure that entraps sister DNAs. The ring is opened either by separase, which cleaves Scc1 during anaphase, or by a releasing activity involving Wapl, Scc3, and Pds5, which bind to Scc1 and open its interface with Smc3. We present crystal structures of Pds5 from the yeast L. thermotolerans in the presence and absence of the conserved Scc1 region that interacts with Pds5. Scc1 binds along the spine of the Pds5 HEAT repeat fold and is wedged between the spine and C-terminal hook of Pds5. We have isolated mutants that confirm the observed binding mode of Scc1 and verified their effect on cohesin by immunoprecipitation and calibrated ChIP-seq. The Pds5 structure also reveals architectural similarities to Scc3, the other large HEAT repeat protein of cohesin and, most likely, Scc2. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
What Are “X-shaped” Radio Sources Telling Us? II. Properties of a Sample of 87
NASA Astrophysics Data System (ADS)
Saripalli, Lakshmi; Roberts, David H.
2018-01-01
In an earlier paper, we presented Jansky Very Large Array multi-frequency, multi-array continuum imaging of a unique sample of low-axial ratio radio galaxies. In this paper, the second in the series, we examine the images to learn the phenomenology of how the off-axis emission relates to the main radio source. Inversion-symmetric offset emission appears to be bimodal and to originate from one of two strategic locations: outer ends of radio lobes (outer-deviation) or from inner ends (inner-deviation). The latter sources are almost always associated with edge-brightened sources. With S- and Z-shaped sources being a subset of outer-deviation sources, this class lends itself naturally to explanations involving black hole axis precession. Our data allow us to present a plausible model for the more enigmatic inner-deviation sources with impressive wings; as for outer-deviation sources these too require black hole axis shifts, although they also require plasma backflows into relic channels. Evolution in morphology over time relates the variety in structures in inner-deviation sources including XRGs. With features such as non-collinearities, central inner-S “spine,” corresponding lobe emission peaks, double and protruding hotspots not uncommon, black hole axis precession, drifts, or flips could be active in a significant fraction of radio sources with prominent off-axis emission. At least 4% of radio galaxies appear to undergo black hole axis rotation. Quasars offer a key signature for recognizing rotating axes. With a rich haul of sources that have likely undergone axis rotation, our work shows the usefulness of low-axial ratio sources in pursuing searches for binary supermassive black holes.
NASA Technical Reports Server (NTRS)
Novotny, Rudolph J. (Inventor)
1989-01-01
A balance ring (18) which is shrunk fit within each disk (12) of a rotor is selectively ground for detail balance. A plurality of openings (20) through the outer edge of the balance ring receive weights during the asssembly balance of the rotor. A snap ring (42) retains the weights within the openings.
30 CFR 291.100 - What is the purpose of this part?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER... transporter has denied a shipper of production from the OCS open and nondiscriminatory access to a pipeline... of resolving pipeline access disputes through either Hotline-assisted procedures or alternative...
30 CFR 291.105 - What must a complaint contain?
Code of Federal Regulations, 2010 CFR
2010-07-01
... legal and factual basis for the allegation that a shipper was denied open and nondiscriminatory access... 291.105 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT § 291.105 What must a...
Kita, Yoshiyuki; Kita, Ritsuko; Takeyama, Asuka; Anraku, Ayako; Tomita, Goji; Goldberg, Ivan
2013-01-01
To assess the relationship between macular ganglion cell complex and macular outer retinal thicknesses. Case-control study. Forty-two normal eyes and 91 eyes with primary open-angle glaucoma were studied. Spectral-domain optical coherence tomography (RTVue-100) was used to measure the macular ganglion cell complex and macular outer retinal thickness. Ganglion cell complex to outer retinal thickness ratio was also calculated. The relationships between the ganglion cell complex and outer retinal thicknesses and between the ganglion cell complex to outer retinal thickness ratio and outer retinal thickness were evaluated. There was a positive correlation between ganglion cell complex and outer retinal thicknesses in the normal group and the glaucoma group (r = 0.53, P < 0.001 and r = 0.42, P < 0.001, respectively). In that respect, there was no correlation between ganglion cell complex to outer retinal thickness ratio and outer retinal thickness in the both groups (r = -0.07, P = 0.657, and r = 0.04, P = 0.677, respectively). The ganglion cell complex to outer retinal thickness ratio was 55.65% in the normal group, 45.07% in the glaucoma group. This difference was statistically significant. The ganglion cell complex thickness may be affected by outer retinal thickness, and there is individual variation in the outer retinal thickness. Therefore, when determining the ganglion cell complex, it seems necessary to consider the outer retinal thickness as well. We propose the ratio as a suitable parameter to account for individual variations in outer retinal thickness. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.
Open cycle ocean thermal energy conversion system
Wittig, J. Michael
1980-01-01
An improved open cycle ocean thermal energy conversion system including a flash evaporator for vaporizing relatively warm ocean surface water and an axial flow, elastic fluid turbine having a vertical shaft and axis of rotation. The warm ocean water is transmitted to the evaporator through a first prestressed concrete skirt-conduit structure circumferentially situated about the axis of rotation. The unflashed warm ocean water exits the evaporator through a second prestressed concrete skirt-conduit structure located circumferentially about and radially within the first skirt-conduit structure. The radially inner surface of the second skirt conduit structure constitutes a cylinder which functions as the turbine's outer casing and obviates the need for a conventional outer housing. The turbine includes a radially enlarged disc element attached to the shaft for supporting at least one axial row of radially directed blades through which the steam is expanded. A prestressed concrete inner casing structure of the turbine has upstream and downstream portions respectively situated upstream and downstream from the disc element. The radially outer surfaces of the inner casing portions and radially outer periphery of the axially interposed disc cooperatively form a downwardly radially inwardly tapered surface. An annular steam flowpath of increasing flow area in the downward axial direction is radially bounded by the inner and outer prestressed concrete casing structures. The inner casing portions each include a transversely situated prestressed concrete circular wall for rotatably supporting the turbine shaft and associated structure. The turbine blades are substantially radially coextensive with the steam flowpath and receive steam from the evaporator through an annular array of prestressed concrete stationary vanes which extend between the inner and outer casings to provide structural support therefor and impart a desired flow direction to the steam.
Heatfield, B M; Travis, D F
1975-01-01
The fine structure of regenerating tips of spines of the sea urchin Strongylocentrotus purpuratus was investigated. Each conical tip consisted of an inner dermis, which deposits and contains the calcite skeleton, and an external layer of epidermis. Although cell types termed spherulecytes containing large, intracellular membrane bound spherules were also present in spine tissues, only epidermal and dermal cell types lacking such spherules are described in this paper. The epidermis was composed largely of free cells representing several functional types. Over the apical portion of the tip these cells occurred in groups, while proximally they were distributed within longitudinal grooves present along the periphery of the spine from the base to the tip. The terminal portions of apical processes extending from some of the epidermal cells formed a thin, contiguous outer layer consisting of small individual islands of cytoplasm bearing microvilli. Adjacent islands were connected around the periphery by a junctional complex extending roughly 200 A in depth in which the opposing plasma membranes were separated by a narrow gap about 145 A in width bridged by amorphous material. Other epidermal cells were closely associated with the basal lamina, which was 900 A in thickness and delineated the dermoepidermal junction; some of these cells appeared to synthesize the lamina, while others may be sensory nerve cells. The dermis at the spine tip also consisted of several functional types of free cells; the most interesting of these was the calcoblast, which deposits the skeleton. Calcoblasts extended a thin, cytoplasmic skeletal sheath which surrounded the tips and adjacent proximal portions of each of the longitudinally oriented microspines comprising the regenerating skeleton, and distally, formed a conical extracellular channel ahead of the mineralizing tip. The intimate relationship between calcoblasts and the growing mineral surface strongly suggests that these cells directly control both the kinetics of mineral deposition and morphogenesis of the skeleton. Other cell types in the dermis were precalcoblasts and phagocytes. Precalcoblasts may function as fibroblasts and are possible precursors of calcoblasts. Closely associated with the basal lamina at the dermoepidermal junction were extracellular unbanded anchoring fi0rils 150 A to 200 A51 in diameter. Scattered proximally among dermal cells were other extracellular fibrils, presumably collagenous, about 300 A in diameter wit
Andaluz, N; Zuccarello, M
2008-06-01
The authors describe a 65-year-old man who, after 7 years of complete remission from lung cancer, was found on routine oncologic follow imaging to have lesions on several vertebral bodies. Open biopsy of the affected thoracic vertebrae and surrounding soft tissue were negative for neoplasia. Bacteriology cultures revealed colonies of aspergillus fumigatus in all bone samples. Unlike most reported cases in which vertebral compromise rarely extends to more than two adjacent vertebrae, our patient had extensive compromise of the thoracic spine. This infection progressed despite treatment with antifungal regimens known to be effective, even in immunocompromised patients. Invasive aspergillosis of the spine is a rare and typically occurred in terminal patients. However, the spectrum of hosts and clinical presentations of invasive aspergillosis are increasing, due in part to better medical treatments that prolong the survival of patients with cancer, severe infections, and organ failure. In reviewing the literature, the authors discuss the currently available therapies for such infections of the spine, and highlight the growing incidence these and other formerly rare infections.
River, Yaron; Aharony, Shelly; Bracha, Jillian; Levital, Tamir; Gerwin, Robert
2014-07-01
Manual therapies for chronic neck pain are imprecise, inconsistent, and brief due to therapist fatigue. A previous study showed that computerized mobilization of the cervical spine in the sagittal plane is a safe and potentially effective treatment of chronic neck pain. To investigate the safety and efficacy of computerized mobilization of the cervical spine in a three-dimensional space for the treatment of chronic neck pain. Pilot, open trial. Physical therapy outpatient department. Nine patients with chronic neck pain. A computerized cradle capable of three-dimensional neck mobilizations was used. Treatment sessions lasted 20 minutes, biweekly, for six weeks. Visual analog scale (VAS) for pain, cervical range of motion (CROM), neck disability index (NDI), joint position error (JPE), and muscle algometry. Comparing baseline at week one with week six (end of treatment), the VAS scores dropped by 2.9 points (P < 0.01). The six directions of movement studied by the CROM showed a combined increase of 11% (P = 0.01). The NDI decreased significantly from 16 to 10 (P = 0.03), and the JPE decreased significantly from 3.7° to 1.9° (P = 0.047). There was no change in the pressure pain threshold in any muscle tested. There were no significant adverse effects. These preliminary results demonstrate that this novel, computerized, three-dimensional cervical mobilization device is probably safe. The data also suggest that this method is effective in alleviating neck pain and associated headache, and in increasing the CROM, although the sample size was small in this open trial. Wiley Periodicals, Inc.
Airfoil for a gas turbine engine
Liang, George [Palm City, FL
2011-05-24
An airfoil is provided for a turbine of a gas turbine engine. The airfoil comprises: an outer structure comprising a first wall including a leading edge, a trailing edge, a pressure side, and a suction side; an inner structure comprising a second wall spaced from the first wall and at least one intermediate wall; and structure extending between the first and second walls so as to define first and second gaps between the first and second walls. The second wall and the at least one intermediate wall define at least one pressure side supply cavity and at least one suction side supply cavity. The second wall may include at least one first opening near the leading edge of the first wall. The first opening may extend from the at least one pressure side supply cavity to the first gap. The second wall may further comprise at least one second opening near the trailing edge of the outer structure. The second opening may extend from the at least one suction side supply cavity to the second gap. The first wall may comprise at least one first exit opening extending from the first gap through the pressure side of the first wall and at least one second exit opening extending from the second gap through the suction side of the second wall.
30 CFR 291.100 - What is the purpose of this part?
Code of Federal Regulations, 2010 CFR
2010-07-01
... from the OCS open and nondiscriminatory access to a pipeline; (b) Explains the procedures MMS will... Section 291.100 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT § 291.100 What is the...
Malham, Gregory M; Parker, Rhiannon M
2018-04-01
OBJECTIVE Image guidance for spine surgery has been reported to improve the accuracy of pedicle screw placement and reduce revision rates and radiation exposure. Current navigation and robot-assisted techniques for percutaneous screws rely on bone-anchored trackers and Kirchner wires (K-wires). There is a paucity of published data regarding the placement of image-guided percutaneous screws without K-wires. A new skin-adhesive stereotactic patient tracker (SpineMask) eliminates both an invasive bone-anchored tracker and K-wires for pedicle screw placement. This study reports the authors' early experience with the use of SpineMask for "K-wireless" placement of minimally invasive pedicle screws and makes recommendations for its potential applications in lumbar fusion. METHODS Forty-five consecutive patients (involving 204 screws inserted) underwent K-wireless lumbar pedicle screw fixation with SpineMask and intraoperative neuromonitoring. Screws were inserted by percutaneous stab or Wiltse incisions. If required, decompression with or without interbody fusion was performed using mini-open midline incisions. Multimodality intraoperative neuromonitoring assessing motor and sensory responses with triggered electromyography (tEMG) was performed. Computed tomography scans were obtained 2 days postoperatively to assess screw placement and any cortical breaches. A breach was defined as any violation of a pedicle screw involving the cortical bone of the pedicle. RESULTS Fourteen screws (7%) required intraoperative revision. Screws were removed and repositioned due to a tEMG response < 13 mA, tactile feedback, and 3D fluoroscopic assessment. All screws were revised using the SpineMask with the same screw placement technique. The highest proportion of revisions occurred with Wiltse incisions (4/12, 33%) as this caused the greatest degree of SpineMask deformation, followed by a mini midline incision (3/26, 12%). Percutaneous screws via a single stab incision resulted in the fewest revisions (7/166, 4%). Postoperative CT demonstrated 7 pedicle screw breaches (3%; 5 lateral, 1 medial, 1 superior), all with percutaneous stab incisions (7/166, 4%). The radiological accuracy of the SpineMask tracker was 97% (197/204 screws). No patients suffered neural injury or required postoperative screw revision. CONCLUSIONS The noninvasive cutaneous SpineMask tracker with 3D image guidance and tEMG monitoring provided high accuracy (97%) for percutaneous pedicle screw placement via stab incisions without K-wires.
Frei, Sina; Fürst, Anton E; Sacks, Murielle; Bischofberger, Andrea S
2016-05-18
Three horses that were presented with supraglenoid tubercle fractures were treated with open reduction and internal fixation using distal femoral locking plates (DFLP). Placing the DFLP caudal to the scapular spine in order to preserve the suprascapular nerve led to a stable fixation, however, it resulted in infraspinatus muscle atrophy and mild scapulohumeral joint instability (case 1). Placing the DFLP cranial to the scapular spine and under the suprascapular nerve resulted in a stable fixation, however, it resulted in severe atrophy of the supraspinatus and infraspinatus muscles and scapulohumeral joint instability (case 2). Placing the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage site resulted in the best outcome (case 3). Only a mild degree of supraspinatus and infraspinatus muscle atrophy was apparent, which resolved quickly and with no effect on scapulohumeral joint stability. In all cases, fixation of supraglenoid tubercle fractures using DFLP in slightly different techniques led to stable fixations with good long-term outcome. One case suffered from a mild incisional infection and plates were removed in two horses. Placement of the DFLP cranial to the scapular spine and slightly overbending it at the suprascapular nerve passage prevented major nerve damage. Further cases investigating the degree of muscle atrophy following the use of the DFLP placed in the above-described technique are justified to improve patient outcome.
Benefits of Spine Stabilization with Biodegradable Scaffolds in Spinal Cord Injured Rats
Silva, Nuno A.; Sousa, Rui A.; Fraga, Joana S.; Fontes, Marco; Leite-Almeida, Hugo; Cerqueira, Rui; Almeida, Armando; Sousa, Nuno; Reis, Rui L.
2013-01-01
Spine stabilization upon spinal cord injury (SCI) is a standard procedure in clinical practice, but rarely employed in experimental models. Moreover, the application of biodegradable biomaterials for this would come as an advantage as it would eliminate the presence of a nondegradable prosthesis within the vertebral bone. Therefore, in the present work, we propose the use of a new biodegradable device specifically developed for spine stabilization in a rat model of SCI. A 3D scaffold based on a blend of starch with polycaprolactone was implanted, replacing delaminated vertebra, in male Wistar rats with a T8-T9 spinal hemisection. The impact of spinal stabilization on the locomotor behavior was then evaluated for a period of 12 weeks. Locomotor evaluation—assessed by Basso, Beatie, and Bresnahan test; rotarod; and open field analysis—revealed that injured rats subjected to spine stabilization significantly improved their motor performance, including higher coordination and rearing activity when compared with SCI rats without stabilization. Histological analysis further revealed that the presence of the scaffolds not only stabilized the area, but also simultaneously prevented the infiltration of the injury site by connective tissue. Overall, these results reveal that SCI stabilization using a biodegradable scaffold at the vertebral bone level leads to an improvement of the motor deficits and is a relevant element for the successful treatment of SCI. PMID:22779715
Heat pump water heater and method of making the same
Mei, Viung C.; Tomlinson, John J.; Chen, Fang C.
2001-01-01
An improved heat pump water heater wherein the condenser assembly of the heat pump is inserted into the water tank through an existing opening in the top of the tank, the assembly comprising a tube-in-a-tube construction with an elongated cylindrical outer body heat exchanger having a closed bottom with the superheated refrigerant that exits the compressor of the heat pump entering the top of the outer body. As the refrigerant condenses along the interior surface of the outer body, the heat from the refrigerant is transferred to the water through the outer body. The refrigerant then enters the bottom of an inner body coaxially disposed within the outer body and exits the top of the inner body into the refrigerant conduit leading into the expansion device of the heat pump. The outer body, in a second embodiment of the invention, acts not only as a heat exchanger but also as the sacrificial anode in the water tank by being constructed of a metal which is more likely to corrode than the metal of the tank.
Laying hen movement in a commercial aviary: Enclosure to floor and back again.
Campbell, D L M; Makagon, M M; Swanson, J C; Siegford, J M
2016-01-01
Many producers in the laying hen industry, including in North America, are phasing out conventional cages in response to consumer demands and sometimes subsequent legislation. Alternative housing systems such as aviaries are being implemented in an attempt to improve hen welfare. Aviaries provide additional space and resources to groups of hens, including a litter area on the floor. However, little is known about hen movement between tiered enclosures and floor litter areas in aviary systems. Diurnal rhythms and social attraction may result in peak times of movement that could lead to overcrowding of areas, or alternatively hen preferences may lead to some areas not being fully utilized. We monitored hen movement between tiered enclosures and litter areas, including movement on and off the outer perch, across the day at peak, mid and end of lay in a commercial aviary. Hens moved onto and off of the open litter area across the day, transitioning between tiered enclosures, outer perches, open litter areas, and litter areas under tiered enclosures. At certain times of day, there were periods of greater hen movement down to the open litter area and between litter areas. For example, more hens were typically observed exiting enclosures, jumping from perches to open litter, and traveling between open litter and litter under tiered enclosures in the morning (all P ≤ 0.001). In all but one instance, more hens were observed on open litter areas in the afternoon than at other times of day (all P ≤ 0.029). However, hen re-entry to tiered enclosures showed less circadian patterning. Hen movement was observed between areas of interest at all sampled time periods, indicating hens use all areas of the system. Further research should examine whether all individual hens do move between areas equally, including within levels of the tiered enclosure, or if crowding occurs on the outer perches or in the litter during times of peak movement. © 2015 Poultry Science Association Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vemareddy, P.; Wiegelmann, T., E-mail: vema@prl.res.in, E-mail: wiegelmann@mps.mpg.de
We study the quasi-static evolution of coronal magnetic fields constructed from the non-linear force-free field (NLFFF) approximation aiming to understand the relation between the magnetic field topology and ribbon emission during an X1.5 flare in active region (AR) NOAA 11166. The flare with a quasi-elliptical and two remote ribbons occurred on 2011 March 9 at 23:13 UT over a positive flux region surrounded by negative flux at the center of the bipolar AR. Our analysis of the coronal magnetic structure with potential and NLFFF solutions unveiled the existence of a single magnetic null point associated with a fan-spine topology andmore » is co-spatial with the hard X-ray source. The footpoints of the fan separatrix surface agree with the inner edge of the quasi-elliptical ribbon and the outer spine is linked to one of the remote ribbons. During the evolution, the slow footpoint motions stressed the field lines along the polarity inversion line and caused electric current layers in the corona around the fan separatrix surface. These current layers trigger magnetic reconnection as a consequence of dissipating currents, which are visible as cusp-shaped structures at lower heights. The reconnection process reorganized the magnetic field topology whose signatures are observed at the separatrices/quasi-separatrix layer structure in both the photosphere and the corona during the pre-to-post flare evolution. In agreement with previous numerical studies, our results suggest that the line-tied footpoint motions perturb the fan-spine system and cause null point reconnection, which eventually causes the flare emission at the footpoints of the field lines.« less
Factors Associated With Narcotic Use After Clavicle Fractures.
Weinberg, Douglas S; Napora, Joshua K; West, William H; Grimberg, Dominic C; Vallier, Heather A
2016-09-01
Clavicle fractures are common in adults. Recent studies have shown that operative treatment of clavicle fractures has benefits in many situations. However, there is controversy about the indications. Data on social outcomes are limited. A total of 434 patients with 436 clavicle fractures treated both operatively and nonoperatively at a level 1 trauma center were identified. Narcotic use was recorded 2, 4, 6, 8, 10, 12, 14, and 16 weeks after injury for both treatment groups. Other descriptive data included age, sex, laterality, hand dominance, rib fractures, smoking, alcohol use, employment, long bone or spine fracture, open clavicle fracture, and mechanism of injury. Logistic regression analysis was performed to determine the independent predictors of narcotic use after clavicle fracture. Open reduction and internal fixation was performed in 105 fractures (24%), and 329 fractures were managed nonoperatively. A total of 154 patients (35%) reported some narcotic use 2 weeks after injury, and 15% were still using narcotics 16 weeks after injury. Narcotic use decreased over time in patients treated with open reduction and internal fixation (10% vs 15% after nonoperative management). Patients treated with open reduction and internal fixation reported reduced narcotic use at 16 weeks (odds ratio [OR], 0.454; P=.070). Concurrent rib fracture (OR, 5.668; P<.001), smoking (OR, 3.095; P=.013), unemployment (OR, 5.429; P<.0005), and long bone or spine fracture (OR, 6.761; P<.001) were predictors of narcotic use. Further studies of the social, economic, and financial outcomes of clavicle fracture and osteosynthesis are warranted. [Orthopedics. 2016; 39(5):e917-e923.]. Copyright 2016, SLACK Incorporated.
Disposable penis and its replenishment in a simultaneous hermaphrodite
Sekizawa, Ayami; Seki, Satoko; Tokuzato, Masakazu; Shiga, Sakiko; Nakashima, Yasuhiro
2013-01-01
Although it is often thought that sexual selection is weaker in simultaneous hermaphrodites than in gonochorists, some simultaneous hermaphrodites exhibit bizarre mating behaviour. In the simultaneously hermaphroditic nudibranch Chromodoris reticulata, we found a peculiar mating behaviour, wherein the nudibranch autotomized its penis after each copulation and was able to copulate again within 24 h. To have sufficient length to be replenished for three copulations, the penis is compressed and spiralled internally. No other animal is known to repeatedly copulate using such ‘disposable penes’. Entangled sperm masses were observed on the outer surface of the autotomized penis, which is equipped with many backward-pointed spines. There is a possibility that the nudibranch removes sperm already stored in a mating partner's sperm storage organ(s). PMID:23407499
Thermal reactor for afterburning automotive internal combustion engine exhaust gases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Masaki, K.; Nagaishi, H.
1974-08-08
A thermal reactor for burning unburned components in exhaust gases of an internal combustion engine before emission to the atmosphere is described. An outer casing has an exhaust gas inlet connected to the exhaust ports, and an inner casing divides the reactor into an outer chamber and an inner chamber. The inner casing has an inlet from the outer chamber, an outlet to the atmosphere, and perforations opening to the outer chamber. An oxidation catalyst in the inner chamber promotes oxidation of the unburned components in the exhaust gases to generate oxidation reaction heat. A first secondary air injection nozzlemore » in the inner chamber between the oxidation catalyst and the outlet and a second secondary air injection nozzle in a portion upstream of the oxidation catalyst inject secondary air into oxidation catalyst.« less
Leach, David; Bergendahl, Peter Allen; Waldo, Stuart Forrest; Smith, Robert Leroy; Phelps, Robert Kim
2001-01-01
A turbine includes upper and lower inner shell sections mounting the nozzles and shrouds and which inner shell is supported by pins secured to a surrounding outer shell. To disassemble the turbine for access to the inner shell sections and rotor, an alignment fixture is secured to the lower outer shell section and has pins engaging the inner shell section. To disassemble the turbine, the inner shell weight is transferred to the lower outer shell section via the alignment fixture and cradle pins. Roller assemblies are inserted through access openings vacated by support pins to permit rotation of the lower inner shell section out of and into the lower outer shell section during disassembly and assembly. The alignment fixture includes adjusting rods for adjusting the inner shell axially, vertically, laterally and about a lateral axis. A roller over-cage is provided to rotate the inner shell and a dummy shell to facilitate assembly and disassembly in the field.
α-Synuclein fibril-induced paradoxical structural and functional defects in hippocampal neurons.
Froula, Jessica M; Henderson, Benjamin W; Gonzalez, Jose Carlos; Vaden, Jada H; Mclean, John W; Wu, Yumei; Banumurthy, Gokulakrishna; Overstreet-Wadiche, Linda; Herskowitz, Jeremy H; Volpicelli-Daley, Laura A
2018-05-01
Neuronal inclusions composed of α-synuclein (α-syn) characterize Parkinson's Disease (PD) and Dementia with Lewy bodies (DLB). Cognitive dysfunction defines DLB, and up to 80% of PD patients develop dementia. α-Syn inclusions are abundant in the hippocampus, yet functional consequences are unclear. To determine if pathologic α-syn causes neuronal defects, we induced endogenous α-syn to form inclusions resembling those found in diseased brains by treating hippocampal neurons with α-syn fibrils. At seven days after adding fibrils, α-syn inclusions are abundant in axons, but there is no cell death at this time point, allowing us to assess for potential alterations in neuronal function that are not caused by neuron death. We found that exposure of neurons to fibrils caused a significant reduction in mushroom spine densities, adding to the growing body of literature showing that altered spine morphology is a major pathologic phenotype in synucleinopathies. The reduction in spine densities occurred only in wild type neurons and not in neurons from α-syn knockout mice, suggesting that the changes in spine morphology result from fibril-induced corruption of endogenously expressed α-syn. Paradoxically, reduced postsynaptic spine density was accompanied by increased frequency of miniature excitatory postsynaptic currents (EPSCs) and presynaptic docked vesicles, suggesting enhanced presynaptic function. Action-potential dependent activity was unchanged, suggesting compensatory mechanisms responding to synaptic defects. Although activity at the level of the synapse was unchanged, neurons exposed to α-syn fibrils, showed reduced frequency and amplitudes of spontaneous Ca 2+ transients. These findings open areas of research to determine the mechanisms that alter neuronal function in brain regions critical for cognition at time points before neuron death.
Fisher, Charles G; Saravanja, Davor D; Dvorak, Marcel F; Rampersaud, Y Raja; Clarkson, Paul W; Hurlbert, John; Fox, Richard; Zhang, Hongbin; Lewis, Stephen; Riaz, Salman; Ferguson, Peter C; Boyd, Michael C
2011-05-01
Multicenter ambispective cohort analysis. The purpose of this study is to determine whether applying Enneking's principles to surgical management of primary bone tumors of the spine significant decreases local recurrence and/or mortality. Oncologic management of primary tumors of spine has historically been inconsistent, controversial, and open to individual interpretation. A multicenter ambispective cohort analysis from 4 tertiary care spine referral centers was done. Patients were analyzed in 2 cohorts, "Enneking Appropriate" (EA), surgical margin as recommended by Enneking, and "Enneking Inappropriate" (EI), surgical margin not recommended by Enneking. Benign tumors were not included in mortality analysis. Two cohorts represented an analytic dataset with 147 patients, 86 male, average age 46 years (range: 10-83). Median follow-up was 4 (2-7) years in the EA and 6 (5.5-15.5) years in the EI. Seventy-one patients suffered at least 1 local recurrence during the study, 57 of 77 in the EI group and 14 of 70 in the EA group. EI surgical approach caused higher risk of first local recurrence (P < 0.0001). There were 48 deaths in total; 29 in the EI group and 19 in the EA. There was a strong correlation between the first local recurrence and mortality with an odds ratio of 4.69, (P < 0.0001). EI surgical approach resulted in a higher risk of mortality with a hazard ratio of 3.10, (P = 0.0485) compared to EA approach. Surgery results in a significant reduction in local recurrence when primary bone tumors of the spine are resected with EA margins. Local recurrence has a high concordance with mortality in resection of these tumors. A significant decrease in mortality occurs when EA surgery is used.
Cervical Spine Injuries: A Whole-Body Musculoskeletal Model for the Analysis of Spinal Loading.
Cazzola, Dario; Holsgrove, Timothy P; Preatoni, Ezio; Gill, Harinderjit S; Trewartha, Grant
2017-01-01
Cervical spine trauma from sport or traffic collisions can have devastating consequences for individuals and a high societal cost. The precise mechanisms of such injuries are still unknown as investigation is hampered by the difficulty in experimentally replicating the conditions under which these injuries occur. We harness the benefits of computer simulation to report on the creation and validation of i) a generic musculoskeletal model (MASI) for the analyses of cervical spine loading in healthy subjects, and ii) a population-specific version of the model (Rugby Model), for investigating cervical spine injury mechanisms during rugby activities. The musculoskeletal models were created in OpenSim, and validated against in vivo data of a healthy subject and a rugby player performing neck and upper limb movements. The novel aspects of the Rugby Model comprise i) population-specific inertial properties and muscle parameters representing rugby forward players, and ii) a custom scapula-clavicular joint that allows the application of multiple external loads. We confirm the utility of the developed generic and population-specific models via verification steps and validation of kinematics, joint moments and neuromuscular activations during rugby scrummaging and neck functional movements, which achieve results comparable with in vivo and in vitro data. The Rugby Model was validated and used for the first time to provide insight into anatomical loading and cervical spine injury mechanisms related to rugby, whilst the MASI introduces a new computational tool to allow investigation of spinal injuries arising from other sporting activities, transport, and ergonomic applications. The models used in this study are freely available at simtk.org and allow to integrate in silico analyses with experimental approaches in injury prevention.
Spine abnormalities depicted by magnetic resonance imaging in adolescent rowers.
Maurer, Marvin; Soder, Ricardo Bernardi; Baldisserotto, Matteo
2011-02-01
Most lesions of the spine of athletes, which often are detected incidentally, do not cause important symptoms or make the athletes discontinue their physical activities. To better understand the significance of these lesions, new imaging studies have been conducted with asymptomatic athletes in several sports, aiming to detect potentially deleterious and disabling abnormalities. To compare the magnetic resonance imaging (MRI) lumbar spine findings in a group of asymptomatic adolescent rowers and in a control group of adolescents matched according to age and sex who do not practice any regular physical activity. Cohort study (prevalence); Level of evidence, 3. Our study evaluated 44 asymptomatic adolescent boys distributed in 2 groups of 22 rowers and 22 control subjects. All the examinations were performed using a 0.35-T open-field MRI unit and evaluated by 2 experienced radiologists blinded to the study groups. Each MRI scan was analyzed for the presence of disc degeneration/desiccation, herniated or bulging disc, pars interarticularis stress reaction, and spondylolysis. The Student t test and the Fisher exact test were used for statistical analyses. Nine rowers (40.9%) had at least 1 abnormality detected by MRI in the lumbar spine, whereas only 2 participants (9.1%) in the control group had at least 1 MRI abnormality (P = .03). Seven disc changes (31.8%) and 6 pars abnormalities (27.3%) were found in the group of elite rowers. In the control group, 3 disc changes (13.6%) and no pars abnormalities were found in the MR scans. The comparison between groups showed statistically significant differences in stress reaction of the pars articularis. Disc disease and pars interarticularis stress reaction are prevalent abnormalities of the lumbar spine of high-performance rowers.
Cervical Spine Injuries: A Whole-Body Musculoskeletal Model for the Analysis of Spinal Loading
Holsgrove, Timothy P.; Preatoni, Ezio; Gill, Harinderjit S.; Trewartha, Grant
2017-01-01
Cervical spine trauma from sport or traffic collisions can have devastating consequences for individuals and a high societal cost. The precise mechanisms of such injuries are still unknown as investigation is hampered by the difficulty in experimentally replicating the conditions under which these injuries occur. We harness the benefits of computer simulation to report on the creation and validation of i) a generic musculoskeletal model (MASI) for the analyses of cervical spine loading in healthy subjects, and ii) a population-specific version of the model (Rugby Model), for investigating cervical spine injury mechanisms during rugby activities. The musculoskeletal models were created in OpenSim, and validated against in vivo data of a healthy subject and a rugby player performing neck and upper limb movements. The novel aspects of the Rugby Model comprise i) population-specific inertial properties and muscle parameters representing rugby forward players, and ii) a custom scapula-clavicular joint that allows the application of multiple external loads. We confirm the utility of the developed generic and population-specific models via verification steps and validation of kinematics, joint moments and neuromuscular activations during rugby scrummaging and neck functional movements, which achieve results comparable with in vivo and in vitro data. The Rugby Model was validated and used for the first time to provide insight into anatomical loading and cervical spine injury mechanisms related to rugby, whilst the MASI introduces a new computational tool to allow investigation of spinal injuries arising from other sporting activities, transport, and ergonomic applications. The models used in this study are freely available at simtk.org and allow to integrate in silico analyses with experimental approaches in injury prevention. PMID:28052130
Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami
2016-11-01
A cadaveric laboratory study. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P < 0.05), specifically significant increases of perfectly placed screws (51% vs. 30%, P < 0.05) and reductions in breaches beyond 4 mm (2% vs. 25%, P < 0.05). All morphometric dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. N/A.
Visuo-proprioceptive interactions in degenerative cervical spine diseases requiring surgery.
Freppel, S; Bisdorff, A; Colnat-Coulbois, S; Ceyte, H; Cian, C; Gauchard, G; Auque, J; Perrin, P
2013-01-01
Cervical proprioception plays a key role in postural control, but its specific contribution is controversial. Postural impairment was shown in whiplash injuries without demonstrating the sole involvement of the cervical spine. The consequences of degenerative cervical spine diseases are underreported in posture-related scientific literature in spite of their high prevalence. No report has focused on the two different mechanisms underlying cervicobrachial pain: herniated discs and spondylosis. This study aimed to evaluate postural control of two groups of patients with degenerative cervical spine diseases with or without optokinetic stimulation before and after surgical treatment. Seventeen patients with radiculopathy were recruited and divided into two groups according to the spondylotic or discal origin of the nerve compression. All patients and a control population of 31 healthy individuals underwent a static posturographic test with 12 recordings; the first four recordings with the head in 0° position: eyes closed, eyes open without optokinetic stimulation, with clockwise and counter clockwise optokinetic stimulations. These four sensorial situations were repeated with the head rotated 30° to the left and to the right. Patients repeated these 12 recordings 6weeks postoperatively. None of the patients reported vertigo or balance disorders before or after surgery. Prior to surgery, in the eyes closed condition, the herniated disc group was more stable than the spondylosis group. After surgery, the contribution of visual input to postural control in a dynamic visual environment was reduced in both cervical spine diseases whereas in a stable visual environment visual contribution was reduced only in the spondylosis group. The relative importance of visual and proprioceptive inputs to postural control varies according to the type of pathology and surgery tends to reduce visual contribution mostly in the spondylosis group. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.
Robotic retroperitoneal partial nephrectomy: a step-by-step guide.
Ghani, Khurshid R; Porter, James; Menon, Mani; Rogers, Craig
2014-08-01
To describe a step-by-step guide for successful implementation of the retroperitoneal approach to robotic partial nephrectomy (RPN) PATIENTS AND METHODS: The patient is placed in the flank position and the table fully flexed to increase the space between the 12th rib and iliac crest. Access to the retroperitoneal space is obtained using a balloon-dilating device. Ports include a 12-mm camera port, two 8-mm robotic ports and a 12-mm assistant port placed in the anterior axillary line cephalad to the anterior superior iliac spine, and 7-8 cm caudal to the ipsilateral robotic port. Positioning and port placement strategies for successful technique include: (i) Docking robot directly over the patient's head parallel to the spine; (ii) incision for camera port ≈1.9 cm (1 fingerbreadth) above the iliac crest, lateral to the triangle of Petit; (iii) Seldinger technique insertion of kidney-shaped balloon dilator into retroperitoneal space; (iv) Maximising distance between all ports; (v) Ensuring camera arm is placed in the outer part of the 'sweet spot'. The retroperitoneal approach to RPN permits direct access to the renal hilum, no need for bowel mobilisation and excellent visualisation of posteriorly located tumours. © 2014 The Authors. BJU International © 2014 BJU International.
Kumar, Naresh; Malhotra, Rishi; Maharajan, Karthikeyan; Zaw, Aye S; Wu, Pang Hung; Makandura, Milindu C; Po Liu, Gabriel Ka; Thambiah, Joseph; Wong, Hee-Kit
2017-10-01
Prospective cohort study. Minimally invasive spinal surgery (MISS) has been gaining recognition in patients with metastatic spine disease (MSD). The advantages are reduction in blood loss, hospital stay, and postoperative morbidity. Most of the studies were case series with very few comparing the outcomes of MISS to open approaches. To evaluate and compare the clinical and perioperative outcomes of MISS versus open approach in patients with symptomatic MSD, who underwent posterior spinal stabilization and/or decompression. Our study included 45 MSD patients; 27 managed by MISS and 18 by open approach. All patients had MSD presenting with symptoms of neurological deficit, spinal instability, or both. Preoperative, intraoperative, and postoperative data were collected for comparison of the 2 approaches. All patients were followed up until the end of study period (maximum up to 4 years from time of surgery) or till their demise. The clinical outcome measures were pain control, neurological and functional status, whereas perioperative outcomes were blood loss, operative time, length of hospital stay, and time taken to initiate radiotherapy/chemotherapy after index surgery. Majority of patients in both groups showed improvement in pain, neurological status, independent ambulation, and ECOG score in the postoperative period with no significant differences between the 2 groups. There was a significant reduction in intraoperative blood loss (621 mL less, P<0.001) in the MISS group. The average time to initiate radiotherapy after surgery was 13 days (range, 12-16 d) in MISS and 24 days (range, 16-40 d) in the open group. This difference was statistically significant (P<0.001). Operative time and duration of hospital stay were also favorable in the MISS group, although the differences were not significant. MISS is comparable with open approach demonstrating similar improvements in clinical outcomes, that is pain control, neurological and functional status. MISS approaches have also shown promising results due to lesser intraoperative blood loss and allowing earlier radiotherapy/chemotherapy.
Aerosol can waste disposal device
O'Brien, Michael D.; Klapperick, Robert L.; Bell, Chris
1993-01-01
Disclosed is a device for removing gases and liquid from containers. The ice punctures the bottom of a container for purposes of exhausting gases and liquid from the container without their escaping into the atmosphere. The device includes an inner cup or cylinder having a top portion with an open end for receiving a container and a bottom portion which may be fastened to a disposal or waste container in a substantially leak-proof manner. A piercing device is mounted in the lower portion of the inner cylinder for puncturing the can bottom placed in the inner cylinder. An outer cylinder having an open end and a closed end fits over the top portion of the inner cylinder in telescoping engagement. A force exerted on the closed end of the outer cylinder urges the bottom of a can in the inner cylinder into engagement with the piercing device in the bottom of the inner cylinder to form an opening in the can bottom, thereby permitting the contents of the can to enter the disposal container.
Aerosol can waste disposal device
O'Brien, M.D.; Klapperick, R.L.; Bell, C.
1993-12-21
Disclosed is a device for removing gases and liquid from containers. The device punctures the bottom of a container for purposes of exhausting gases and liquid from the container without their escaping into the atmosphere. The device includes an inner cup or cylinder having a top portion with an open end for receiving a container and a bottom portion which may be fastened to a disposal or waste container in a substantially leak-proof manner. A piercing device is mounted in the lower portion of the inner cylinder for puncturing the can bottom placed in the inner cylinder. An outer cylinder having an open end and a closed end fits over the top portion of the inner cylinder in telescoping engagement. A force exerted on the closed end of the outer cylinder urges the bottom of a can in the inner cylinder into engagement with the piercing device in the bottom of the inner cylinder to form an opening in the can bottom, thereby permitting the contents of the can to enter the disposal container. 7 figures.
DexterNet: An Open Platform for Heterogeneous Body Sensor Networks and Its Applications
2008-12-19
motion, ECG PC, PDA 802.15.4 No No ALARM-NET pulse oximetry STARGATE Bluetooth No Yes [19] motion, ECG PDA, PC 802.11 (temperature, light, PIR) DexterNet...motion, ECG PDA 802.15.4 Yes Possible via SPINE EIP, GPS PC (e.g., air pollution sensor) MICAz, SHIMMER uses MICAz sensors and STARGATE to relay the
NASA Technical Reports Server (NTRS)
Chern, Shy-Shiun (Inventor)
1981-01-01
A coaxial stub tuner assembly is comprised of a short circuit branch diametrically opposite an open circuit branch. The stub of the short circuit branch is tubular, and the stub of the open circuit branch is a rod which extends through the tubular stub into the open circuit branch. The rod is threaded at least at its outer end, and the tubular stub is internally threaded to receive the threads of the rod. The open circuit branch can be easily tuned by turning the threaded rod in the tubular stub to adjust the length of the rod extending into the open circuit branch.
Teegala, Madhavi L; Vinayak, Dhamangaonkar G
2017-01-01
The fourth ventricle, seen as intracranial translucency (IT) at 11-13 +6 weeks, has been reported to be obliterated in cases of open spina bifida (OSB). Our aim was to assess its role in detecting OSB at 11-13 +6 weeks. This prospective study was conducted at foetal medicine unit from January 2014 to June 2015. All women who underwent both first and mid-trimester scan in our unit were included in the study. IT was categorized as normal, obliterated or not clear. Spine was examined during both scans. Totally, 341 cases were included in the study. IT was found to be obliterated in four cases and not clear in one case. There was demonstrable OSB at 11-13 +6 weeks in two cases, at 15-16 weeks in two cases and at 24 weeks in one case. In the remaining 336 cases with normal IT, spine was found to be normal at target scan. Mid-sagittal view of face that is routinely used to measure nuchal translucency (NT) can also be used to detect OSB. It is feasible to integrate IT into the routine 11-13 +6 weeks scan.
Warren, Michelle P; Miller, K K; Olson, W H; Grinspoon, S K; Friedman, A J
2005-09-01
The effects of long-term triphasic oral contraceptive administration on bone mineral density (BMD) were investigated in premenopausal women with hypothalamic amenorrhea (HA) and osteopenia. After completing three 28-day cycles in the double-blind phase of a placebo-controlled trial, women (mean age, 26.7 years) who received norgestimate 180-250 microg/ethinyl estradiol 35 microg (NGM/EE, n = 15) or placebo (n = 12) in the double-blind phase were to receive open-label NGM/EE for 10 additional cycles. For subjects completing > or =10 NGM/EE treatment cycles, mean posteroanterior total lumbar spine BMD (L1-L4) increased from 0.881+/-0.0624 g/cm2 at baseline (last visit prior to NGM/EE) to 0.894+/-0.0654 g/cm2 at final visit (p = .043); no significant changes in hip BMD occurred. Decreases in N-telopeptide, osteocalcin, procollagen type I propeptide and bone-specific alkaline phosphatase levels indicated effects on bone metabolism. Long-term administration of triphasic NGM/EE to osteopenic women with HA may increase total lumbar spine BMD.
Draper, Robert; Prevish, Thomas; Bronson, Angela; George, Raymond A.
2007-01-02
A solid oxide fuel assembly is made, wherein rows (14, 25) of fuel cells (17, 19, 21, 27, 29, 31), each having an outer interconnection (20) and an outer electrode (32), are disposed next to each other with corrugated, electrically conducting expanded metal mesh member (22) between each row of cells, the corrugated mesh (22) having top crown portions and bottom portions, where the top crown portion (40) have a top bonded open cell nickel foam (51) which contacts outer interconnections (20) of the fuel cells, said mesh and nickel foam electrically connecting each row of fuel cells, and where there are no more metal felt connections between any fuel cells.
Mahato, Niladri Kumar; Sybert, Daryl; Law, Tim; Clark, Brian
2017-05-01
Our objective was to use an open weight-bearing MRI to identify the effects of different loading conditions on the inter-vertebral anatomy of the lumbar spine in a post-discectomy recurrent lumbar disc herniation patient. A 43-year-old male with a left-sided L5-S1 post-decompression re-herniation underwent MR imaging in three spine-loading conditions: (1) supine, (2) weight-bearing on standing (WB), and (3) WB with 10 % of body mass axial loading (WB + AL) (5 % through each shoulder). A segmentation-based proprietary software was used to calculate and compare linear dimensions, angles and cross sections across the lumbar spine. The L5 vertebrae showed a 4.6 mm posterior shift at L5-S1 in the supine position that changed to an anterior translation >2.0 mm on WB. The spinal canal sagittal thickness at L5-S1 reduced from supine to WB and WB + AL (13.4, 10.6, 9.5 mm) with corresponding increases of 2.4 and 3.5 mm in the L5-S1 disc protrusion with WB and WB + AL, respectively. Change from supine to WB and WB + AL altered the L5-S1 disc heights (10.2, 8.6, 7.0 mm), left L5-S1 foramen heights (12.9, 11.8, 10.9 mm), L5-S1 segmental angles (10.3°, 2.8°, 4.3°), sacral angles (38.5°, 38.3°, 40.3°), L1-L3-L5 angles (161.4°, 157.1°, 155.1°), and the dural sac cross sectional areas (149, 130, 131 mm 2 ). Notably, the adjacent L4-L5 segment demonstrated a retro-listhesis >2.3 mm on WB. We observed that with weight-bearing, measurements indicative of spinal canal narrowing could be detected. These findings suggest that further research is warranted to determine the potential utility of weight-bearing MRI in clinical decision-making.
McGirt, Matthew J; Parker, Scott L; Mummaneni, Praveen; Knightly, John; Pfortmiller, Deborah; Foley, Kevin; Asher, Anthony L
2017-07-01
Over the last decade, clinical investigators and biomedical industry groups have used significant resources to develop advanced technologies that enable less invasive spine fusions. These minimally invasive surgery (MIS) technologies often require increased expenditures by hospitals and payers. Although several small single center studies have suggested MIS technologies decrease surgical morbidity and reduce hospital stay, evidence documenting benefit from a patient perspective remains limited. Furthermore, MIS outcomes have yet to be evaluated from the perspective of multiple practice types representing the broad spectrum of US spine surgery. This study aimed to examine a population of patients who underwent one- or two-level interbody lumbar fusion diagnosed with lumbar stenosis or Grade 1 spondylolisthesis in an observational, prospective national registry for the purposes of determining how MIS and traditional open technologies affect postsurgical and patient-reported outcomes (PROs). This study used observational analysis of prospectively collected data. The sample consisted of cases from the National Neurosurgery Quality and Outcomes Database (N 2 QOD). Numeric rating scale for back and leg pain, Oswestry Disability Index, EuroQol-5D, return to work, and perioperative morbidity were the outcome measures. The N 2 QOD is a prospective PROs registry enrolling patients undergoing elective spine surgery from 60 hospitals in 27 US states via representative sampling. We analyzed the N 2 QOD aggregate dataset (2010-2014) to identify one- and two-level lumbar interbody fusion procedures performed for lumbar stenosis or Grade 1 spondylolisthesis with 12 months' follow-up where surgical instrumentation and implant types were clearly identified. Perioperative and 1-year outcomes were compared between cases performed with MIS enabling technologies versus traditional open technologies before and after propensity matching. There were 467 (24%) patients who underwent elective interbody lumbar fusion using MIS enabling technologies whereas 1,480 (76%) underwent the procedure using traditional open technologies. The MIS patients were slightly healthier (American Society of Anesthesiologists grade), had private insurance more frequently, and underwent two-level fusion less frequently. Unmatched, the MIS cohort was associated with reduced blood loss, a 0.7-day reduction in mean length of hospital stay, and 5% reduced need for post-discharge inpatient rehabilitation, but equivalent 90-day safety measures. After propensity matching, the MIS cohort remained associated with reduced blood loss and a shorter length of stay for one-level fusion (p<.05) but had equivalent length of stay for two-level fusion. Outcomes in all other 90-day safety measures were similar. In both unadjusted and propensity-matched comparison, MIS versus open technologies were associated with equivalent return to work, patient-reported pain, physical disability, and quality of life at 3 and 12 months' follow-up. In a representative sampling registry of elective interbody lumbar spine fusion procedures spanning 27 US states, nearly a quarter of procedures performed from 2010 to 2014 used minimally invasive enabling technologies. Regardless of approach, interbody lumbar fusion was associated with significant and sustained improvements in all measured health domains. When used in everyday care by a wide spectrum of spine surgeons in non-research settings, the use of MIS technologies was associated with reduced intraoperative blood loss but only a half-day reduction in mean length of hospital stay for one-level fusions. Minimally invasive surgery was not associated with any improved perioperative safety measures or 12-month outcomes. Although MIS enabling technologies may increase some in-hospital care efficiencies, MIS clinical outcomes are similar to open surgery for patients undergoing one- and two-level interbody lumbar fusions. Copyright © 2017 Elsevier Inc. All rights reserved.
Grancara, Silvia; Ohkubo, Shinji; Artico, Marco; Ciccariello, Mauro; Manente, Sabrina; Bragadin, Marcantonio; Toninello, Antonio; Agostinelli, Enzo
2016-10-01
Mitochondria represent cell "powerhouses," being involved in energy transduction from the electrochemical gradient to ATP synthesis. The morphology of their cell types may change, according to various metabolic processes or osmotic pressure. A new morphology of the inner membrane and mitochondrial cristae, significantly different from the previous one, has been proposed for the inner membrane and mitochondrial cristae, based on the technique of electron tomography. Mitochondrial Ca(2+) transport (the transporter has been isolated) generates reactive oxygen species and induces the mitochondrial permeability transition of both inner and outer mitochondrial membranes, leading to induction of necrosis and apoptosis. In the mitochondria of several cell types (liver, kidney, and heart), mitochondrial oxidative stress is an essential step in the induction of cell death, although not in brain, in which the phenomenon is caused by a different mechanism. Mitochondrial permeability transition drives both apoptosis and necrosis, whereas mitochondrial outer membrane permeability is characteristic of apoptosis. Adenine nucleotide translocase remains the most important component involved in membrane permeability, with the opening of the transition pore, although other proteins, such as ATP synthase or phosphate carriers, have been proposed. Intrinsic cell death is triggered by the release from mitochondria of proteic factors, such as cytochrome c, apoptosis inducing factor, and Smac/DIABLO, with the activation of caspases upon mitochondrial permeability transition or mitochondrial outer membrane permeability induction. Mitochondrial permeability transition induces the permeability of the inner membrane in sites in contact with the outer membrane; mitochondrial outer membrane permeability forms channels on the outer membrane by means of various stimuli involving Bcl-2 family proteins. The biologically active amines, spermine, and agmatine, have specific functions on mitochondria which distinguish them from other amines. Enzymatic oxidative deamination of spermine by amine oxidases in tumor cells may produce reactive oxygen species, leading to transition pore opening and apoptosis. This process could be exploited as a new therapeutic strategy to combat cancer.
NASA Technical Reports Server (NTRS)
Mosqueira, I.; Estrada, P. R.
2000-01-01
We model the subnebulae of Jupiter and Saturn wherein satellite accretion took place. We expect a giant planet subnebula to be composed of an optically thick (given gaseous opacity) inner region inside of the planet's centrifugal radius (located at r(sub c, sup J) = l5R(sub J) for Jupiter and r(sub c, sup S) = 22R(sub S) for Saturn), and an optically thin, extended outer disk out to a fraction of the planet's Roche lobe, which we choose to be R(sub roche)/5 (located at approximately 150R(sub J) near the inner irregular satellites for Jupiter, and approximately 200R(sub S) near Phoebe for Saturn). This places Titan and Ganymede in the inner disk, Callisto and Iapetus in the outer disk, and Hyperion in the transition region. The inner disk is the leftover of the gas accreted by the protoplanet. The outer disk results from the solar torque on nebula gas flowing into the protoplanet during the time of giant planet gap opening. For the sake of specificity, we use a cosmic mixture 'minimum mass' model to constrain the gas densities of the inner disks of Jupiter and Saturn (and also Uranus). For the total mass of the outer disk we use the simple scaling M(sub disk) = M(sub P)tau(sub gap)/tau(sub acc), where M(sub P) is the mass of the giant planet, tau(sub gap) is the gap opening timescale, and tau(sub acc) is the giant planet accretion time. This gives a total outer disk mass of approximately 100M(sub Callisto) for Jupiter and possibly approximately 200M(sub Iapetus) for Saturn (which contain enough condensables to form Callisto and Iapetus respectively). Our model has Ganymede at a subnebula temperature of approximately 250 K and Titan at approximately 100 K. The outer disks of Jupiter and Saturn have constant temperatures of 130 K and 90 K respectively.
Apparatus for integrating a rigid structure into a flexible wall of an inflatable structure
NASA Technical Reports Server (NTRS)
Johnson, Christopher J. (Inventor); Patterson, Ross M. (Inventor); Spexarth, Gary R. (Inventor)
2009-01-01
For an inflatable structure having a flexible outer shell or wall structure having a flexible restraint layer comprising interwoven, load-bearing straps, apparatus for integrating one or more substantially rigid members into the flexible shell. For each rigid member, a corresponding opening is formed through the flexible shell for receiving the rigid member. A plurality of connection devices are mounted on the rigid member for receiving respective ones of the load-bearing straps. In one embodiment, the connection devices comprise inner connecting mechanisms and outer connecting mechanisms, the inner and outer connecting mechanisms being mounted on the substantially rigid structure and spaced along a peripheral edge portion of the structure in an interleafed array in which respective outer connecting mechanisms are interposed between adjacent pairs of inner connecting mechanisms, the outer connecting mechanisms projecting outwardly from the peripheral edge portion of the substantially rigid structure beyond the adjacent inner connecting mechanisms to form a staggered array of connecting mechanisms extending along the panel structure edge portion. In one embodiment, the inner and outer connecting mechanisms form part of an integrated, structure rotatably mounted on the rigid member peripheral edge portion.
Code of Federal Regulations, 2010 CFR
2010-07-01
... decision on whether a grantee or transporter has provided open and nondiscriminatory access? 291.112 Section 291.112 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT § 291.112 What process...
Bland, Robert J [Oviedo, FL; Horazak, Dennis A [Orlando, FL
2012-03-06
A gas turbine engine is provided comprising an outer shell, a compressor assembly, at least one combustor assembly, a turbine assembly and duct structure. The outer shell includes a compressor section, a combustor section, an intermediate section and a turbine section. The intermediate section includes at least one first opening and at least one second opening. The compressor assembly is located in the compressor section to define with the compressor section a compressor apparatus to compress air. The at least one combustor assembly is coupled to the combustor section to define with the combustor section a combustor apparatus. The turbine assembly is located in the turbine section to define with the turbine section a turbine apparatus. The duct structure is coupled to the intermediate section to receive at least a portion of the compressed air from the compressor apparatus through the at least one first opening in the intermediate section, pass the compressed air to an apparatus for separating a portion of oxygen from the compressed air to produced vitiated compressed air and return the vitiated compressed air to the intermediate section via the at least one second opening in the intermediate section.
2004-01-22
KENNEDY SPACE CENTER, FLA. - A worker in the Orbiter Processing Facility checks the open hatch of the airlock in Discovery’s payload bay. The airlock is normally located inside the middeck of the spacecraft’s pressurized crew cabin. The airlock is sized to accommodate two fully suited flight crew members simultaneously. Support functions include airlock depressurization and repressurization, extravehicular activity equipment recharge, liquid-cooled garment water cooling, EVA equipment checkout, donning and communications. The outer hatch isolates the airlock from the unpressurized payload bay when closed and permits the EVA crew members to exit from the airlock to the payload bay when open.
The martian moons as the remnants of a giant impact
NASA Astrophysics Data System (ADS)
Ronnet, T.; Vernazza, P.; Mousis, O.; Brugger, B.; Beck, P.; Devouard, B.; Witasse, O.; Cipriani, F.
2017-09-01
The origin of Phobos and Deimos is still an open question. Currently, none of the three proposed scenarios for their origin (intact capture of two distinct outer solar system small bodies, co-accretion with Mars, and accretion within an impact-generated disk) is able to reconcile their orbital and physical properties. Here we show that gas-to-solid condensation of the building blocks in the outer part of an extended impact-generated disk could reproduce the spectral and physical properties of the moons.
Microfabricated linear Paul-Straubel ion trap
Mangan, Michael A [Albuquerque, NM; Blain, Matthew G [Albuquerque, NM; Tigges, Chris P [Albuquerque, NM; Linker, Kevin L [Albuquerque, NM
2011-04-19
An array of microfabricated linear Paul-Straubel ion traps can be used for mass spectrometric applications. Each ion trap comprises two parallel inner RF electrodes and two parallel outer DC control electrodes symmetric about a central trap axis and suspended over an opening in a substrate. Neighboring ion traps in the array can share a common outer DC control electrode. The ions confined transversely by an RF quadrupole electric field potential well on the ion trap axis. The array can trap a wide array of ions.
The Controversy Surrounding Bone Morphogenetic Proteins in the Spine: A Review of Current Research
Hustedt, Joshua W.; Blizzard, Daniel J.
2014-01-01
Bone morphogenetic proteins have been in use in spinal surgery since 2002. These proteins are members of the TGF-beta superfamily and guide mesenchymal stem cells to differentiate into osteoblasts to form bone in targeted tissues. Since the first commercial BMP became available in 2002, a host of research has supported BMPs and they have been rapidly incorporated in spinal surgeries in the United States. However, recent controversy has arisen surrounding the ethical conduct of the research supporting the use of BMPs. Yale University Open Data Access (YODA) recently teamed up with Medtronic to offer a meta-analysis of the effectiveness of BMPs in spinal surgery. This review focuses on the history of BMPs and examines the YODA research to guide spine surgeons in their use of BMP in spinal surgery. PMID:25506287
Gough-Palmer, A L; Burnett, C; Gedroyc, W M
2009-08-01
The aim of this study was to evaluate 12 years of general practitioner (GP) use of open access MRI services at a single London teaching hospital. A retrospective analysis of reports from all GP requests for MRI scans between 1994 and 2005 was performed. The date, scanned body part, and requester details from 1798 scans requested by 209 individual GPs over a continuous 12-year period were recorded. All scans were then graded into four categories based on the severity of reported findings from normal to gross abnormality. Over the study period, GP requests as a percentage of the total (MRI) department workload remained low at approximately 2.6%. Spine, knee and brain requests constituted 86% (n = 1546) of requested scans. 48% (n = 868) of scans were reported as normal or minor degenerative changes only. 26% (n = 466) of scans demonstrated serious pathology that was likely to warrant hospital consultant referral. There was a wide range of scans requested per requester, from 1 to 240 over the period, with an average of 8.5 scans per GP. In conclusion, any department wishing to set up open access to MRI services for GPs could cover the majority of requests by offering spine, knee and brain imaging. The percentage of normal report rates for GP requests is comparable with previous studies of outpatient referrals. A large variation in requesting patterns between GPs suggests the need for increased communication between GPs and imaging departments to optimise use of the service.
1980-04-01
specifications ... 3-10 25. Typical isolation curve ... 3-12 26. Servo amp/motor/load frequency response (inner gimbal) ... 4-3 27. Slave loop ( open loop...slave loop ( open loop) frequency response (inner gimbal) . . . 4-4 30. Slave loop (closed loop) frequency response (inner gimbal) ... 4-5 3 . Slave...loop inner gimbal time response ... 4-5 32. Servo amp/motor/load frequency response (outer gimbal) ... 4-6 33. Slave loop ( open loop) uncompensated
Gomes, Tássia Fernanda Furo; Melo, Francisco Tiago de Vasconcelos; Giese, Elane Guerreiro; Furtado, Adriano Penha; Santos, Jeannie Nascimento Dos
2017-01-01
The trematodes are parasites of the several vertebrates including amphibians, however the knowledge about of the taxonomy these parasites is still confuse. The trematode Choledocystus elegans was found in the small intestine of the Leptodactylus paraensis in eastern Amazon and presents the following characteristics: several pointed tegumentary spines, papillae on the outer and inner edges of the oral and ventral suckers, a round, well-developed cirrus sac, a well-developed cirrus, oblique testicles, a ovary right side, uterine loops extending between the testicles, follicular vitellaria distributed throughout the body, starting at the genital pore region and caeca close the end of the body. For the first time, this study identified C. elegans parasitizing L. paraensis and describes morphological aspects never characterized using light and scanning electron microscopy.
Cooling circuit for steam and air-cooled turbine nozzle stage
Itzel, Gary Michael; Yu, Yufeng
2002-01-01
The turbine vane segment includes inner and outer walls with a vane extending therebetween. The vane includes leading and trailing edge cavities and intermediate cavities. An impingement plate is spaced from the outer wall to impingement-cool the outer wall. Post-impingement cooling air flows through holes in the outer wall to form a thin air-cooling film along the outer wall. Cooling air is supplied an insert sleeve with openings in the leading edge cavity for impingement-cooling the leading edge. Holes through the leading edge afford thin-film cooling about the leading edge. Cooling air is provided the trailing edge cavity and passes through holes in the side walls of the vane for thin-film cooling of the trailing edge. Steam flows through a pair of intermediate cavities for impingement-cooling of the side walls. Post-impingement steam flows to the inner wall for impingement-cooling of the inner wall and returns the post-impingement cooling steam through inserts in other intermediate cavities for impingement-cooling the side walls of the vane.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, K; Gil, M; Li, G
Purpose: To develop a novel approach to improve cervical spine (c-spine) curvature reproducibility for head and neck (HN) patients using optical surface imaging (OSI) with two regions of interests (ROIs). Methods: The OSI-guided, two-step setup procedure requires two ROIs: ROI-1 of the shoulders and ROI-2 of the face. The neck can be stretched or squeezed in superior-inferior (SI) direction using a specially-designed sliding head support. We hypothesize that when these two ROIs are aligned, the c-spine should fall into a naturally reproducible position under same setup conditions. An anthropomorphous phantom test was performed to examine neck pitch angles comparing withmore » the calculated angles. Three volunteers participated in the experiments, which start with conventional HN setup using skin markers and room lasers. An OSI image and lateral photo-picture were acquired as the references. In each of the three replicate tests, conventional setup was first applied after volunteers got on the couch. ROI-1 was aligned by moving the body, followed by ROI-2 alignment via adjusting head position and orientation under real-time OSI guidance. A final static OSI image and lateral picture were taken to evaluate both anterior and posterior surface alignments. Three degrees of freedom can be adjusted if an open-face mask was applied, including head SI shift using the sliding head support and pitch-and-roll rotations using a commercial couch extension. Surface alignment was analyzed comparing with conventional setup. Results: The neck pitch angle measured by OSI is consistent with the calculated (0.2±0.6°). Volunteer study illustrated improved c-spine setup reproducibility using OSI comparing with conventional setup. ROI alignments with 2mm/1° tolerance are achieved within 3 minutes. Identical knee support is important to achieve ROI-1 pitch alignment. Conclusion: The feasibility of this novel approach has been demonstrated for c-spine curvature setup reproducibility. Further evaluation is necessary with bony alignment variation in patient studies. This study is in part supported by the NIH (U54CA137788).« less
Valve assembly for use with high temperature and high pressure fluids
De Feo, Angelo
1982-01-01
The valve assembly for use with high temperature and high pressure fluids has inner and outer spaced shells and a valve actuator support of inner and outer spaced members which are connected at their end portions to the inner and outer shells, respectively, to extend substantially normal to the longitudinal axis of the inner shell. A layer of resilient heat insulating material covers the outer surfaces of the inner shell and the inner actuator support member and is of a thickness to only occupy part of the spaces between the inner and outer shells and inner and outer actuator support members. The remaining portion of the space between the inner and outer shells and the space between the inner and outer members is substantially filled with a body of castable, rigid refractory material. A movable valve member is disposed in the inner shell. A valve actuator assembly is supported in the valve actuator support to extend into the inner shell for connection with the movable valve member for movement of the movable valve member to positions from a fully open to a fully closed position to control flow of fluid through the inner shell. An anchor mneans is disposed adjacent opposite sides of the axis of the valve actuator support and attached to the inner shell so that relative radial movement between the inner and outer shell is permitted by the layer of resilient heat insulating material and relative longitudinal movement of the inner shell to the outer shell is permitted in opposite directions from the anchor means to thereby maintain the functional integrity of the movable valve member by providing an area of the inner shell surrounding the movable valve member longitdinally stationary, but at the same time allowing radial movement.
Combustion-gas recirculation system
Baldwin, Darryl Dean
2007-10-09
A combustion-gas recirculation system has a mixing chamber with a mixing-chamber inlet and a mixing-chamber outlet. The combustion-gas recirculation system may further include a duct connected to the mixing-chamber inlet. Additionally, the combustion-gas recirculation system may include an open inlet channel with a solid outer wall. The open inlet channel may extend into the mixing chamber such that an end of the open inlet channel is disposed between the mixing-chamber inlet and the mixing-chamber outlet. Furthermore, air within the open inlet channel may be at a pressure near or below atmospheric pressure.
Models of anxiety: responses of rats to novelty in an open space and an enclosed space.
Ennaceur, A; Michalikova, S; Chazot, P L
2006-07-15
Exposure to novelty has been shown to induce anxiety responses in a variety of behavioural paradigms. The purpose of the present study was to investigate whether exposition of naïve rats to novelty would result in a comparable or a different pattern of responses in an open space versus enclosed space with or without the presence of an object in the centre of the field. Lewis and Wistar rats of both genders were used to illustrate and discuss the value and validity of these anxiety paradigms. We examined a wide range of measures, which cover several aspects of animals' responses. The results of this study revealed significant differences between the behaviour of animals in an open space and in the enclosed space. It also revealed significant differences in animal's responses to the presence and absence of an object in the open space and in the enclosed space. In the enclosed space, rats spent most of their time in the outer area with lower number of exits and avoided the object area except when there was an object, while in the open space rats displayed frequent short duration re-entries in the outer area and spent longer time in the object area in presence of an object. The time spent in the inner area (away from the outer area and the object area) was significantly longer and the number of faecal boli was significantly higher in the open space than in the enclosed space. In the present report, we will discuss the fundamental differences between enclosed space and open space models, and we will examine some methodological issues related to the current animal models of human behaviour in anxiety. In the enclosed space, animals can avoid the potential threat associated with the centre area of a box and chose the safety of walls and corners, whereas, in the open space animals have to avoid every parts of the field from which there was no safe escape. The response of animals to novelty in an open space model appears more relevant to anxiety than in an enclosed space. The present studies revealed no correlations between the measures of behaviour in enclosed space and the measures of behaviour in open space, which suggest that these two models do not involve the same construct. Our results suggest that the enclosed space model involves avoidance responses while the open space model involves anxiety responses. The open space model can be very useful in understanding the underlying neural mechanisms of anxiety responses, and in assessing the effects of potential anxiolytic drugs.
Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study.
Ruatti, Sébastien; Dubois, C; Chipon, E; Kerschbaumer, G; Milaire, M; Moreau-Gaudry, A; Tonetti, J; Merloz, Ph
2016-06-01
We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 × 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 × 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 × 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).
Outer region scaling using the freestream velocity for nonuniform open channel flow over gravel
NASA Astrophysics Data System (ADS)
Stewart, Robert L.; Fox, James F.
2017-06-01
The theoretical basis for outer region scaling using the freestream velocity for nonuniform open channel flows over gravel is derived and tested for the first time. Owing to the gradual expansion of the flow within the nonuniform case presented, it is hypothesized that the flow can be defined as an equilibrium turbulent boundary layer using the asymptotic invariance principle. The hypothesis is supported using similarity analysis to derive a solution, followed by further testing with experimental datasets. For the latter, 38 newly collected experimental velocity profiles across three nonuniform flows over gravel in a hydraulic flume are tested as are 43 velocity profiles previously published in seven peer-reviewed journal papers that focused on fluid mechanics of nonuniform open channel over gravel. The findings support the nonuniform flows as equilibrium defined by the asymptotic invariance principle, which is reflective of the consistency of the turbulent structure's form and function within the expanding flow. However, roughness impacts the flow structure when comparing across the published experimental datasets. As a secondary objective, we show how previously published mixed scales can be used to assist with freestream velocity scaling of the velocity deficit and thus empirically account for the roughness effects that extend into the outer region of the flow. One broader finding of this study is providing the theoretical context to relax the use of the elusive friction velocity when scaling nonuniform flows in gravel bed rivers; and instead to apply the freestream velocity. A second broader finding highlighted by our results is that scaling of nonuniform flow in gravel bed rivers is still not fully resolved theoretically since mixed scaling relies to some degree on empiricism. As researchers resolve the form and function of macroturbulence in the outer region, we hope to see the closing of this research gap.
Yau, Suk-Yu; Li, Ang; Tong, Jian-Bin; Bostrom, Crystal; Christie, Brian R; Lee, Tatia M C; So, Kwok-Fai
2016-09-21
Our previous work has shown that exposure to the stress hormone corticosterone (40 mg/kg CORT) for two weeks induces dendritic atrophy of pyramidal neurons in the hippocampal CA3 region and behavioral deficits. However, it is unclear whether this treatment also affects the dentate gyrus (DG), a subregion of the hippocampus comprising a heterogeneous population of young and mature neurons. We examined the effect of CORT treatment on the dendritic complexity of mature and young granule cells in the DG. We utilized a Golgi staining method to investigate the dendritic morphology and spine density of young neurons in the inner granular cell layer (GCL) and mature neurons in the outer GCL in response to CORT application. The expressions of glucocorticoid receptors during neuronal maturation were examined using Western blot analysis in a primary hippocampal neuronal culture. Sholl analysis revealed that CORT treatment decreased the number of intersections and shortened the dendritic length in mature, but not young, granule cells. However, the spine density of mature and young neurons was not affected. Western blot analysis showed a progressive increase in the protein levels of glucocorticoid receptors (GRs) in the cultured primary hippocampal neurons during neuronal maturation. These data suggest that mature neurons are likely more vulnerable to chronic exposure to CORT; this may be due to their higher expression of GRs when compared to younger DG neurons.
Grano-Maldonado, M I
2014-01-01
This study examines the transmission strategies employed by parasites in order to colonize new hosts. Three-spined sticklebacks, Gasterosteus aculeatus L., were challenged with Gyrodactylus gasterostei Gläser, 1974 in a chamber and the colonization of new hosts was observed. Live-video recording indicates that gyrodactylid transmission possibly maximizes the chances of contact with an alternatively feeding response from dead parasitized hosts to predatory stickleback. It is proposed that host scavenge feeding may comprise an additional route for gyrodactylid transmission, although its relative importance with respect to other recognized routes remains uncertain. Although it was clearly demonstrated that G. gasterostei can reside in the mouth of its host, the study revealed that scavenging-feeding upon dead parasitized hosts did not contribute significantly to the level of infection in 3 h and parasite transmission observed on the feeding fish. A series of experimental exposures and scanning electron microscope images suggest that once ingested, the parasites can attach to the lining of the buccal cavity and then migrate to their preferred colonization site on the outer surface of the fish. In addition to the direct contact infection pathway normally associated with many. This study highlights that diagnosticians should be aware of the fact that the oral cavity may act as temporary transmission location for gyrodactylid fauna. © 2014 Wiley Periodicals, Inc.
Teegala, Madhavi L; Vinayak, Dhamangaonkar G
2017-01-01
Aims and Objectives: The fourth ventricle, seen as intracranial translucency (IT) at 11–13+6 weeks, has been reported to be obliterated in cases of open spina bifida (OSB). Our aim was to assess its role in detecting OSB at 11–13+6 weeks. Materials and Methods: This prospective study was conducted at foetal medicine unit from January 2014 to June 2015. All women who underwent both first and mid-trimester scan in our unit were included in the study. IT was categorized as normal, obliterated or not clear. Spine was examined during both scans. Results: Totally, 341 cases were included in the study. IT was found to be obliterated in four cases and not clear in one case. There was demonstrable OSB at 11–13+6 weeks in two cases, at 15–16 weeks in two cases and at 24 weeks in one case. In the remaining 336 cases with normal IT, spine was found to be normal at target scan. Conclusion: Mid-sagittal view of face that is routinely used to measure nuchal translucency (NT) can also be used to detect OSB. It is feasible to integrate IT into the routine 11–13+6 weeks scan. PMID:29379237
Management of symptomatic vertebral haemangioma in a resource challenged environment.
Adeolu, Augustine A; Balogun, James A; Adeleye, Amos O; Adeoye, Peter O; Okolo, Clement A; Ogbole, Godwin I
2010-07-01
Vertebral haemangiomas are benign lesions and often asymptomatic. They are more common in the thoracic spine where they may become symptomatic with varying presentations. We present two teenage girls who presented with progressive, nontraumatic paraparesis with no background history of chronic cough or underlying medical illness. The radiologic investigations were suggestive of vertebral haemangiomas of the thoracic spine. They had surgery: transthoracic approach with corpectomy and fusion with iliac crest autograft. The posterior stabilisation in the first patient was with Rush nails and circlage wire and only circlage wire in the second patient. The first patient's post-operative recovery was complicated by graft extrusion necessitating re-opening thoracotomy and graft replacement. They are, however, both ambulant at discharge and have remained so 13 and 15 months post-surgery. We have presented two cases with rewarding outcomes in the face of 'adaptive' instrumentation due to limited resources.
Phan, Kevin; Maharaj, Monish; Assem, Yusuf; Mobbs, Ralph J
2016-09-01
Lumbar interbody fusion represents an effective surgical intervention for patients with lumbar degenerative diseases, spondylolisthesis, disc herniation, pseudoarthrosis and spinal deformities. Traditionally, conventional open anterior lumbar interbody fusion and posterior/transforaminal lumbar interbody fusion techniques have been employed with excellent results, but each with their own advantages and caveats. Most recently, the antero-oblique trajectory has been introduced, providing yet another corridor to access the lumbar spine. Termed the oblique lumbar interbody fusion, this approach accesses the spine between the anterior vessels and psoas muscles, avoiding both sets of structures to allow efficient clearance of the disc space and application of a large interbody device to afford distraction for foraminal decompression and endplate preparation for rapid and thorough fusion. This review aims to summarize the early clinical results and complications of this new technique and discusses potential future directions of research. Copyright © 2016 Elsevier Ltd. All rights reserved.
Abad, Sònia; Fole, Alberto; del Olmo, Nuria; Pubill, David; Pallàs, Mercè; Junyent, Fèlix; Camarasa, Jorge; Camins, Antonio; Escubedo, Elena
2014-03-01
Addictive drugs produce forms of structural plasticity in the nucleus accumbens and prefrontal cortex. The aim of this study was to investigate the impact of chronic MDMA exposure on pyramidal neurons in the CA1 region of hippocampus and drug-related spatial learning and memory changes. Adolescent rats were exposed to saline or MDMA in a regime that mimicked chronic administration. One week later, when acquisition or reference memory was evaluated in a standard Morris water maze (MWM), no differences were obtained between groups. However, MDMA-exposed animals performed better when the MWM was implemented under more difficult conditions. Animals of MDMA group were less anxious and were more prepared to take risks, as in the open field test they ventured more frequently into the central area. We have demonstrated that MDMA caused an increase in brain-derived neurotrophic factor (BDNF) expression. When spine density was evaluated, MDMA-treated rats presented a reduced density when compared with saline, but overall, training increased the total number of spines, concluding that in MDMA-group, training prevented a reduction in spine density or induced its recovery. This study provides support for the conclusion that binge administration of MDMA, known to be associated to neurotoxic damage of hippocampal serotonergic terminals, increases BDNF expression and stimulates synaptic plasticity when associated with training. In these conditions, adolescent rats perform better in a more difficult water maze task under restricted conditions of learning and memory. The effect on this task could be modulated by other behavioural changes provoked by MDMA.
Self-organized formation of GaSb/GaAs quantum rings.
Timm, R; Eisele, H; Lenz, A; Ivanova, L; Balakrishnan, G; Huffaker, D L; Dähne, M
2008-12-19
Ring-shaped GaSb/GaAs quantum dots, grown by molecular beam epitaxy, were studied using cross-sectional scanning tunneling microscopy. These quantum rings have an outer shape of a truncated pyramid with baselengths around 15 nm and heights of about 2 nm but are characterized by a clear central opening extending over about 40% of the outer baselength. They form spontaneously during the growth and subsequent continuous capping of GaSb/GaAs quantum dots due to the large strain and substantial As-for-Sb exchange reactions leading to strong Sb segregation.
2013-07-26
8 (2000 mg/m 3 ) may have produced transient impairment of rat cochlear outer hair cell function in the absence of noise (Fechter et al., 2010); the...system is a dynamic, non- rebreathing system. In this system, an exposure atmosphere flow rate of approximately 0.5 L/min per open port was maintained...exposure atmosphere flow to the chamber or the exhaust. The outer plenum of the nose-only exposure system carried the animals’ exhaled breath and excess
Tan, W Katherine; Hassanpour, Saeed; Heagerty, Patrick J; Rundell, Sean D; Suri, Pradeep; Huhdanpaa, Hannu T; James, Kathryn; Carrell, David S; Langlotz, Curtis P; Organ, Nancy L; Meier, Eric N; Sherman, Karen J; Kallmes, David F; Luetmer, Patrick H; Griffith, Brent; Nerenz, David R; Jarvik, Jeffrey G
2018-03-28
To evaluate a natural language processing (NLP) system built with open-source tools for identification of lumbar spine imaging findings related to low back pain on magnetic resonance and x-ray radiology reports from four health systems. We used a limited data set (de-identified except for dates) sampled from lumbar spine imaging reports of a prospectively assembled cohort of adults. From N = 178,333 reports, we randomly selected N = 871 to form a reference-standard dataset, consisting of N = 413 x-ray reports and N = 458 MR reports. Using standardized criteria, four spine experts annotated the presence of 26 findings, where 71 reports were annotated by all four experts and 800 were each annotated by two experts. We calculated inter-rater agreement and finding prevalence from annotated data. We randomly split the annotated data into development (80%) and testing (20%) sets. We developed an NLP system from both rule-based and machine-learned models. We validated the system using accuracy metrics such as sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). The multirater annotated dataset achieved inter-rater agreement of Cohen's kappa > 0.60 (substantial agreement) for 25 of 26 findings, with finding prevalence ranging from 3% to 89%. In the testing sample, rule-based and machine-learned predictions both had comparable average specificity (0.97 and 0.95, respectively). The machine-learned approach had a higher average sensitivity (0.94, compared to 0.83 for rules-based), and a higher overall AUC (0.98, compared to 0.90 for rules-based). Our NLP system performed well in identifying the 26 lumbar spine findings, as benchmarked by reference-standard annotation by medical experts. Machine-learned models provided substantial gains in model sensitivity with slight loss of specificity, and overall higher AUC. Copyright © 2018 The Association of University Radiologists. All rights reserved.
Effects of Conflicts of Interest on Practice Patterns and Complication Rates in Spine Surgery.
Cook, Ralph W; Weiner, Joseph A; Schallmo, Michael S; Chun, Danielle S; Barth, Kathryn A; Singh, Sameer K; Hsu, Wellington K
2017-09-01
Retrospective cohort study. We sought to determine whether financial relationships with industry had any impact on operative and/or complication rates of spine surgeons performing fusion surgeries. Recent actions from Congress and the Institute of Medicine have highlighted the importance of conflicts of interest among physicians. Orthopedic surgeons and neurosurgeons have been identified as receiving the highest amount of industry payments among all specialties. No study has yet investigated the potential effects of disclosed industry payments with quality and choices of patient care. A comprehensive database of spine surgeons in the United States with compiled data of industry payments, operative fusion rates, and complication rates was created. Practice pattern data were derived from a publicly available Medicare-based database generated from selected CPT codes from 2011 to 2012. Complication rate data from 2009 to 2013 were extracted from the ProPublica-Surgeon-Scorecard database, which utilizes postoperative inhospital mortality and 30-day-readmission for designated conditions as complications of surgery. Data regarding industry payments from 2013 to 2014 were derived from the Open Payments website. Surgeons performing <10 fusions, those without complication data, and those whose identity could not be verified through public records were excluded. Pearson correlation coefficients and multivariate regression analyses were used to determine the relationship between industry payments, operative fusion rate, and/or complication rate. A total of 2110 surgeons met the inclusion criteria for our database. The average operative fusion rate was 8.8% (SD 4.8%), whereas the average complication rate for lumbar and cervical fusion was 4.1% and 1.9%, respectively. Pearson correlation analysis revealed a statistically significant but negligible relationship between disclosed payments/transactions and both operative fusion and complication rates. Our findings do not support a strong correlation between the payments a surgeon receives from industry and their decisions to perform spine fusion or associated complication rates. Large variability in the rate of fusions performed suggests a poor consensus for indications for spine fusion surgery. 3.
The Arrival of Robotics in Spine Surgery: A Review of the Literature.
Ghasem, Alexander; Sharma, Akhil; Greif, Dylan N; Alam, Milad; Maaieh, Motasem Al
2018-04-18
Systematic Review. The authors aim to review comparative outcome measures between robotic and free-hand spine surgical procedures including: accuracy of spinal instrumentation, radiation exposure, operative time, hospital stay, and complication rates. Misplacement of pedicle screws in conventional open as well as minimally invasive surgical procedures has prompted the need for innovation and allowed the emergence of robotics in spine surgery. Prior to incorporation of robotic surgery in routine practice, demonstration of improved instrumentation accuracy, operative efficiency, and patient safety is required. A systematic search of the PubMed, OVID-MEDLINE, and Cochrane databases was performed for papers relevant to robotic assistance of pedicle screw placement. Inclusion criteria were constituted by English written randomized control trials, prospective and retrospective cohort studies involving robotic instrumentation in the spine. Following abstract, title, and full-text review, 32 articles were selected for study inclusion. Intrapedicular accuracy in screw placement and subsequent complications were at least comparable if not superior in the robotic surgery cohort. There is evidence supporting that total operative time is prolonged in robot assisted surgery compared to conventional free-hand. Radiation exposure appeared to be variable between studies; radiation time did decrease in the robot arm as the total number of robotic cases ascended, suggesting a learning curve effect. Multi-level procedures appeared to tend toward earlier discharge in patients undergoing robotic spine surgery. The implementation of robotic technology for pedicle screw placement yields an acceptable level of accuracy on a highly consistent basis. Surgeons should remain vigilant about confirmation of robotic assisted screw trajectory, as drilling pathways have been shown to be altered by soft tissue pressures, forceful surgical application, and bony surface skiving. However, the effective consequence of robot-assistance on radiation exposure, length of stay, and operative time remains unclear and requires meticulous examination in future studies. 4.
Chen, Qun; Xu, Haishan; Xu, Aijun; Ross, Thomas; Bowler, Elizabeth; Hu, Ying; Lesnefsky, Edward J.
2015-01-01
Background Mitochondria are critical to cardiac injury during reperfusion as a result of damage sustained during ischemia, including the loss of bcl-2. We asked if bcl-2 depletion not only leads to selective permeation of the outer mitochondrial membrane (MOMP) favoring cytochrome c release and programmed cell death, but also favors opening of the mitochondrial permeability transition pore (MPTP). An increase in MPTP susceptibility would support a role for bcl-2 depletion mediated cell death in the calcium overload setting of early reperfusion via MPTP as well as later in reperfusion via MOMP as myocardial calcium content normalizes. Methods Calcium retention capacity (CRC) was used to reflect the sensitivity of the MPTP opening in isolated cardiac mitochondria. To study the relationship between bcl-2 inhibition and MPTP opening, mitochondria were incubated with a bcl-2 inhibitor (HA14-1) and CRC measured. The contribution of preserved bcl-2 content to MPTP opening following ischemia-reperfusion was explored using transgenic bcl-2 overexpressed mice. Results CRC was decreased in mitochondria following reperfusion compared to ischemia alone, indicating that reperfusion further sensitizes to MPTP opening. Incubation of ischemia-damaged mitochondria with increasing HA14-1concentrations increased calcium-stimulated MPTP opening, supporting that functional inhibition of bcl-2 during simulated reperfusion favors MPTP opening. Moreover, HA14-1 sensitivity was increased by ischemia compared to non-ischemic controls. Overexpression of bcl-2 attenuated MPTP opening in following ischemia-reperfusion. HA14-1 inhibition also increased the permeability of the outer membrane in the absence of exogenous calcium, indicating that bcl-2 inhibition favors MOMP when calcium is low. Conclusions The depletion and functional inhibition of bcl-2 contributes to cardiac injury by increasing susceptibility to MPTP opening in high calcium environments and MOMP in the absence of calcium overload. Thus, ischemia-damaged mitochondria with decreased bcl-2 content are susceptible to MPTP opening in early reperfusion and MOMP later in reperfusion when cytosolic calcium has normalized. PMID:25756500
2004-01-22
KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility, a cameraman films part of Discovery’s payload bay for a special feature on the KSC Web. In the background is the open hatch of the airlock, located inside the middeck of the spacecraft’s pressurized crew cabin. The airlock is sized to accommodate two fully suited flight crew members simultaneously. Support functions include airlock depressurization and repressurization, extravehicular activity equipment recharge, liquid-cooled garment water cooling, EVA equipment checkout, donning and communications. The outer hatch isolates the airlock from the unpressurized payload bay when closed and permits the EVA crew members to exit from the airlock to the payload bay when open.
2004-01-22
KENNEDY SPACE CENTER, FLA. - Standing inside Discovery’s payload bay, Carol Scott (right), lead orbiter engineer, talks about her job as part of a special feature for the KSC Web. With his back to the camera is Bill Kallus, Media manager in the KSC Web Studio. Behind Scott can be seen the open hatch of the airlock, which provides support functions such as airlock depressurization and repressurization, extravehicular activity equipment recharge, liquid-cooled garment water cooling, EVA equipment checkout, donning and communications. The outer hatch isolates the airlock from the unpressurized payload bay when closed and permits the EVA crew members to exit from the airlock to the payload bay when open.
Retrieval analysis of motion preserving spinal devices and periprosthetic tissues
Kurtz, Steven M.; Steinbeck, Marla; Ianuzzi, Allyson; van Ooij, André; Punt, Ilona M.; Isaza, Jorge; Ross, E.R.S.
2009-01-01
This article reviews certain practical aspects of retrieval analysis for motion preserving spinal implants and periprosthetic tissues as an essential component of the overall revision strategy for these implants. At our institution, we established an international repository for motion-preserving spine implants in 2004. Our repository is currently open to all spine surgeons, and is intended to be inclusive of all cervical and lumbar implant designs such as artificial discs and posterior dynamic stabilization devices. Although a wide range of alternative materials is being investigated for nonfusion spine implants, many of the examples in this review are drawn from our existing repository of metal-on-polyethylene, metal-on-metal lumbar total disc replacements (TDRs), and polyurethane-based dynamic motion preservation devices. These devices are already approved or nearing approval for use in the United States, and hence are the most clinically relevant at the present time. This article summarizes the current literature on the retrieval analysis of these implants and concludes with recommendations for the development of new test methods that are based on the current state of knowledge of in vivo wear and damage mechanisms. Furthermore, the relevance and need to evaluate the surrounding tissue to obtain a complete understanding of the biological reaction to implant component corrosion and wear is reviewed. PMID:25802641
Laryngeal dislocation after ventral fusion of the cervical spine
Krauel, Jenny; Winkler, Dietrich; Münscher, Adrian; Tank, Sascha
2013-01-01
We report on a 70-year-old patient who underwent ventral fusion of the cervical spine (C3/4 and C4/5) for spinal canal stenosis performed by the neurosurgery department. The patient suffered an exceedingly rare complication of the surgery – laryngeal dislocation. Had the deformed laryngeal structures been overlooked and the patient extubated as usual after surgery, reintubation would have been impossible due to the associated swelling, which might have had disastrous consequences. Leftward dislocation of the larynx became apparent post-operatively, but prior to extubation. Extubation was therefore postponed and a subsequent computed tomography (CT) scan revealed entrapment of laryngeal structures within the osteosynthesis. A trial of repositioning using microlaryngoscopy performed by otolaryngology (ears, nose and throat) specialists failed, making open surgical revision necessary. At surgery, the entrapped laryngeal tissue was successfully mobilised. Laryngeal oedema developed despite prompt repositioning; thus, necessitating tracheotomy and long-term ventilation. Laryngeal dislocation may be an unusual cause of post-operative neck swelling after anterior cervical spine surgery and should be considered in the differential diagnosis if surgical site haematoma and other causes have been ruled out. Imaging studies including CT of the neck may be needed before extubation to confirm the suspicion and should be promptly obtained to facilitate specific treatment. PMID:23983289
Use of rapid prototyping drill template for the expansive open door laminoplasty: A cadaveric study.
Rong, Xin; Wang, Beiyu; Chen, Hua; Ding, Chen; Deng, Yuxiao; Ma, Lipeng; Ma, Yanzhao; Liu, Hao
2016-11-01
Trough preparation is a technically demanding yet critical procedure for successful expansive open door laminoplasty (EOLP), requiring both proper position and appropriate bone removal. We aimed to use the specific rapid prototyping drill template to achieve such requirement. The 3D model of the cadaveric cervical spine was reconstructed using the Mimics 17.0 and Geomagic Studio 12.0 software. The drilling template was designed in the 3-Matic software. The trough position was simulated at the medial margin of the facet joint. Two holders were designed on both sides. On the open side, the holder would just allow the drill penetrate the ventral cortex of the lamina. On the hinge side, the holder was designed to keep the ventral cortex of the lamina intact. One orthopedic resident performed the surgery using the rapid prototyping drill template on four cadavers (template group). A control group of four cadavers were operated upon without the use of the template. The deviation of the final trough position from the simulated trough position was 0.18mm±0.51mm in the template group. All the troughs in the template group and 40% of the troughs in the control group were at the medial side of the facet joint. The complete hinge fracture rate was 5% in the template group, significantly lower than that (55%) in the control group (P=0.01). The rapid prototyping drill template could help the surgeon accomplish proper trough position and appropriate bone removal in EOLP on the cadaveric cervical spine. Copyright © 2016 Elsevier B.V. All rights reserved.
Adogwa, Owoicho; Carr, Kevin; Thompson, Paul; Hoang, Kimberly; Darlington, Timothy; Perez, Edgar; Fatemi, Parastou; Gottfried, Oren; Cheng, Joseph; Isaacs, Robert E
2015-05-01
Obese and morbidly obese patients undergoing lumbar spinal fusion surgery are a challenge to the operating surgeon. Minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) and open-TLIF have been performed for many years with good results; however, functional outcomes after lumbar spine surgery in this subgroup of patients remain poorly understood. Furthermore, whether index MIS-TLIF or open-TLIF for the treatment of degenerative disc disease or spondylolisthesis in morbidly obese results in superior postoperative functional outcomes remains unknown. A total of 148 (MIS-TLIF: n = 40, open-TLIF: n = 108) obese and morbidly obese patients undergoing index lumbar arthrodesis for low back pain and/or radiculopathy between January 2003 and December 2010 were selected from a multi-institutional prospective data registry. We collected and analyzed data on patient demographics, postoperative complications, back pain, leg pain, and functional disability over 2 years. Patients completed the Oswestry Disability Index (ODI), Medical Outcomes Study Short-Form 36 (SF-36), and back and leg pain numerical rating scores before surgery and then at 12 and 24 months after surgery. Clinical outcomes and complication rates were compared between both patient cohorts. Compared with preoperative status, Visual Analog Scale (VAS) back and leg pain, ODI, and SF-36 physical component score/mental component score were improved in both groups. Both MIS-TLIF and open-TLIF patients showed similar 2-year improvement in VAS for back pain (MIS-TLIF: 2.42 ± 3.81 vs. open-TLIF: 2.33 ± 3.67, P = 0.89), VAS for leg pain (MIS-TLIF: 3.77 ± 4.53 vs. open-TLIF: 2.67 ± 4.10, P = 0.18), ODI (MIS-TLIF: 11.61 ± 25.52 vs. open-TLIF: 14.88 ± 22.07, P = 0.47), and SF-36 physical component score (MIS-TLIF: 8.61 ± 17.72 vs. open-TLIF: 7.61 ± 15.55, P = 0.93), and SF-36 mental component score (MIS-TLIF: 4.35 ± 22.71 vs. open-TLIF: 5.96 ± 21.09, P = 0.69). Postoperative complications rates between both cohorts were also not significantly divergent between (12.50% vs. 11.11%, P = 0.51). MIS-TLIF is a safe and viable option for lumbar fusion in morbidly obese patients and, compared with open-TLIF, resulted in similar improvement in pain and functional disability. Postoperative complications rates between both cohorts were also not significantly divergent. Copyright © 2015 Elsevier Inc. All rights reserved.
Moye, Abigail R; Singh, Ratnesh; Kimler, Victoria A; Dilan, Tanya L; Munezero, Daniella; Saravanan, Thamaraiselvi; Goldberg, Andrew F X; Ramamurthy, Visvanathan
2018-05-02
The outer segment (OS) of photoreceptor cells is an elaboration of a primary cilium with organized stacks of membranous discs that contain the proteins needed for phototransduction and vision. Though cilia formation and function has been well characterized, little is known about the role of cilia in the development of photoreceptor OS. Nevertheless, progress has been made by studying mutations in ciliary proteins which often result in malformed outer segments and lead to blinding diseases. To investigate how ciliary proteins contribute to outer segment formation, we generated a knockout mouse model for ARL2BP, a ciliary protein linked to Retinitis Pigmentosa. The knockout mice display an early and progressive reduction in visual response. Prior to photoreceptor degeneration we observed disorganization of the photoreceptor OS, with vertically aligned discs and shortened axonemes. Interestingly, ciliary doublet microtubule structure was also impaired, displaying open B-tubule doublets, paired with loss of singlet microtubules. Based on results from this study, we conclude that ARL2BP is necessary for photoreceptor cilia doublet formation and axoneme elongation, which is required for outer segment morphogenesis and vision.
NASA Astrophysics Data System (ADS)
Afzal, Bushra; Noor Afzal Team; Bushra Afzal Team
2014-11-01
The momentum and thermal turbulent boundary layers over a continuous moving sheet subjected to a free stream have been analyzed in two layers (inner wall and outer wake) theory at large Reynolds number. The present work is based on open Reynolds equations of momentum and heat transfer without any closure model say, like eddy viscosity or mixing length etc. The matching of inner and outer layers has been carried out by Izakson-Millikan-Kolmogorov hypothesis. The matching for velocity and temperature profiles yields the logarithmic laws and power laws in overlap region of inner and outer layers, along with friction factor and heat transfer laws. The uniformly valid solution for velocity, Reynolds shear stress, temperature and thermal Reynolds heat flux have been proposed by introducing the outer wake functions due to momentum and thermal boundary layers. The comparison with experimental data for velocity profile, temperature profile, skin friction and heat transfer are presented. In outer non-linear layers, the lowest order momentum and thermal boundary layer equations have also been analyses by using eddy viscosity closure model, and results are compared with experimental data. Retired Professor, Embassy Hotel, Rasal Ganj, Aligarh 202001 India.
Wen, Han; Qin, Feng; Zheng, Wenjun
2016-01-01
As a key cellular sensor, the TRPV1 cation channel undergoes a gating transition from a closed state to an open state in response to various physical and chemical stimuli including noxious heat. Despite years of study, the heat activation mechanism of TRPV1 gating remains enigmatic at the molecular level. Toward elucidating the structural and energetic basis of TRPV1 gating, we have performed molecular dynamics (MD) simulations (with cumulative simulation time of 3 μs), starting from the high-resolution closed and open structures of TRPV1 solved by cryo-electron microscopy. In the closed-state simulations at 30°C, we observed a stably closed channel constricted at the lower gate (near residue I679), while the upper gate (near residues G643 and M644) is dynamic and undergoes flickery opening/closing. In the open-state simulations at 60°C, we found higher conformational variation consistent with a large entropy increase required for the heat activation, and both the lower and upper gates are dynamic with transient opening/closing. Through ensemble-based structural analyses of the closed state vs. the open state, we revealed pronounced closed-to-open conformational changes involving the membrane proximal domain (MPD) linker, the outer pore, and the TRP helix, which are accompanied by breaking/forming of a network of closed/open-state specific hydrogen bonds. By comparing the closed-state simulations at 30°C and 60°C, we observed heat-activated conformational changes in the MPD linker, the outer pore, and the TRP helix that resemble the closed-to-open conformational changes, along with partial formation of the open-state specific hydrogen bonds. Some of the residues involved in the above key hydrogen bonds were validated by previous mutational studies. Taken together, our MD simulations have offered rich structural and dynamic details beyond the static structures of TRPV1, and promising targets for future mutagenesis and functional studies of the TRPV1 channel. PMID:27699868
Rethnam, Ulfin; Yesupalan, Rajam; Gandham, Giri
2008-06-16
A cautious outlook towards neck injuries has been the norm to avoid missing cervical spine injuries. Consequently there has been an increased use of cervical spine radiography. The Canadian Cervical Spine rule was proposed to reduce unnecessary use of cervical spine radiography in alert and stable patients. Our aim was to see whether applying the Canadian Cervical Spine rule reduced the need for cervical spine radiography without missing significant cervical spine injuries. This was a retrospective study conducted in 2 hospitals. 114 alert and stable patients who had cervical spine radiographs for suspected neck injuries were included in the study. Data on patient demographics, high risk & low risk factors as per the Canadian Cervical Spine rule and cervical spine radiography results were collected and analysed. 28 patients were included in the high risk category according to the Canadian Cervical Spine rule. 86 patients fell into the low risk category. If the Canadian Cervical Spine rule was applied, there would have been a significant reduction in cervical spine radiographs as 86/114 patients (75.4%) would not have needed cervical spine radiograph. 2/114 patients who had significant cervical spine injuries would have been identified when the Canadian Cervical Spine rule was applied. Applying the Canadian Cervical Spine rule for neck injuries in alert and stable patients would have reduced the use of cervical spine radiographs without missing out significant cervical spine injuries. This relates to reduction in radiation exposure to patients and health care costs.
Rethnam, Ulfin; Yesupalan, Rajam; Gandham, Giri
2008-01-01
Background A cautious outlook towards neck injuries has been the norm to avoid missing cervical spine injuries. Consequently there has been an increased use of cervical spine radiography. The Canadian Cervical Spine rule was proposed to reduce unnecessary use of cervical spine radiography in alert and stable patients. Our aim was to see whether applying the Canadian Cervical Spine rule reduced the need for cervical spine radiography without missing significant cervical spine injuries. Methods This was a retrospective study conducted in 2 hospitals. 114 alert and stable patients who had cervical spine radiographs for suspected neck injuries were included in the study. Data on patient demographics, high risk & low risk factors as per the Canadian Cervical Spine rule and cervical spine radiography results were collected and analysed. Results 28 patients were included in the high risk category according to the Canadian Cervical Spine rule. 86 patients fell into the low risk category. If the Canadian Cervical Spine rule was applied, there would have been a significant reduction in cervical spine radiographs as 86/114 patients (75.4%) would not have needed cervical spine radiograph. 2/114 patients who had significant cervical spine injuries would have been identified when the Canadian Cervical Spine rule was applied. Conclusion Applying the Canadian Cervical Spine rule for neck injuries in alert and stable patients would have reduced the use of cervical spine radiographs without missing out significant cervical spine injuries. This relates to reduction in radiation exposure to patients and health care costs. PMID:18557998
Repeatability of standard metabolic rate (SMR) in a small fish, the spined loach (Cobitis taenia).
Maciak, Sebastian; Konarzewski, Marek
2010-10-01
Significant repeatability of a trait of interest is an essential assumption for undertaking studies of phenotypic variability. It is especially important in studies on highly variable traits, such as metabolic rates. Recent publications suggest that resting/basal metabolic rate of homeotherms is repeatable across wide range of species. In contrast, studies on the consistency of standard metabolic rate (SMR) in ectotherms, particularly fish, are scarce. Here we present a comprehensive analysis of several important technical aspects of body mass-corrected SMR measurements and its repeatability in a small (average weight approximately 3g) fish, the spined loach (Cobitis taenia). First we demonstrated that release of oxygen from the walls of metabolic chambers exposed to hypoxic conditions did not confound SMR measurements. Next, using principle of propagation of measurement uncertainties we demonstrated that in aquatic systems, measurement error is significantly higher in open than closed respirometry setups. The measurement error for SMR of a small fish determined in a closed aquatic system is comparable to that obtainable using top-notch open-flow systems used for air-breathing terrestrial animals. Using a closed respirometer we demonstrated that body mass-corrected SMR in spined loaches was repeatable under both normoxia and hypoxia over a 5-month period (Pearson correlation r=0.68 and r=0.73, respectively) as well as across both conditions (intraclass correlation coefficient tau=0.30). In these analyses we accounted for possible effect of oxygen consumption of the oxygen electrode on repeatability of SMR. Significant SMR consistency was accompanied by significant repeatability of body mass (intraclass correlation coefficient tau=0.86). To our knowledge, this is the first study showing long-term repeatability of body mass and SMR in a small fish, and is consistent with the existence of heritable variation of these two traits. 2010 Elsevier Inc. All rights reserved.
Haimoto, Shoichi; Schär, Ralph T; Nishimura, Yusuke; Hara, Masahito; Wakabayashi, Toshihiko; Ginsberg, Howard J
2018-05-04
OBJECTIVE Recent studies have demonstrated the efficacy of subfascial intrawound application of vancomycin powder in spine surgery in reducing the rate of surgical site infections (SSIs). However, to date no study has evaluated the efficacy and safety of suprafascial application of vancomycin powder in spine surgery. The purpose of this study was to quantify the rate of SSIs after open instrumented posterior spinal fusion with and without application of suprafascial vancomycin powder and to evaluate the rate of vancomycin powder-related local adverse effects. METHODS The authors conducted a single-center retrospective case-control study of adult patients undergoing open instrumented posterior fusion of the cervical, thoracic, or lumbar spine performed by a single surgeon from January 2010 through December 2016. In March 2013, routine application of 1 g of suprafascial vancomycin powder was started for all cases in addition to standard systemic antibiotic prophylaxis. Baseline demographics and operative data as well as the SSI rates were compared between the study groups. The incidence of vancomycin powder-related adverse effects was analyzed. RESULTS A total of 515 patients (268 in the untreated group and 247 in the treated group) were included in the study. The mean age was significantly higher in the treated group than in the untreated group (58.4 vs 54.4 years, p < 0.01). Operative variables were similar between the study groups. Patients receiving vancomycin powder had a significantly lower infection rate (5.6% in the untreated group vs 0% in the treated group, p < 0.001). No vancomycin powder-related adverse effects were identified in the treated group. CONCLUSIONS Routine application of suprafascial intrawound vancomycin powder in addition to systemic antibiotic prophylaxis is an easy-to-use, safe, and effective strategy for preventing SSIs after instrumented posterior spinal fusion. Suprafascial application of vancomycin powder could be a valuable alternative to previously reported subfascial distribution, minimizing the risk of local adverse drug reactions.
[In vitro function of outer membrane protease T of Escherichia coli K1 pathogenic strain].
Hui, Changye; Guo, Yan; Wu, Shuchi; Peng, Liang; Cao, Hong; Huang, Shenghe
2010-01-01
Plasminogen activation and antimicrobial peptide hydrolysis contribute to pathogens invasion and survival in vivo. To demonstrate the expression of outer membrane protease T in E. coli K1 pathogenic strain E44, its activity of plasminogen activator and protamine hydrolysis. After Benzamidine Sepharose Fast Flow and SOURCE 30Q chromatography, we got E44 outer membrane mixed fraction, and examined its activity of plasminogen activation with chromogenic substrate S-2251 method. An ompT deletion mutant of E44 was constructed by using the suicide vector pCVD442, termed as E44ompT. We examined 0.1 mg/mL cationic antimicrobial peptide protamine susceptibility of E44, ompT mutant strain E44ompT and E44ompT harboring pUCT, which was constructed by inserting complete ompT open reading frame into pUC13. We got about 37 kDa E44 membrane extract, which could activate plasminogen, and activation was membrane extract dose dependent. This confirmed the expression of outer membrane protease T in the outer membrane of E44. E44ompT was, more susceptible to 0.1 mg/mL protamine than E44, and E440mpT was partially complemented by pUCT. Outer membrane protease T is expressed in E. coli K1 pathogenic strain E44, and can activate plasminogen and hydrolyze protamine.
Silvestre, Clément; Mac-Thiong, Jean-Marc; Hilmi, Radwan; Roussouly, Pierre
2012-06-01
A retrospective study including 179 patients who underwent oblique lumbar interbody fusion (OLIF) at one institution. To report the complications associated with a minimally invasive technique of a retroperitoneal anterolateral approach to the lumbar spine. Different approaches to the lumbar spine have been proposed, but they are associated with an increased risk of complications and a longer operation. A total of 179 patients with previous posterior instrumented fusion undergoing OLIF were included. The technique is described in terms of: the number of levels fused, operative time and blood loss. Persurgical and postsurgical complications were noted. Patients were age 54.1 ± 10.6 with a BMI of 24.8 ± 4.1 kg/m(2). The procedure was performed in the lumbar spine at L1-L2 in 4, L2-L3 in 54, L3-L4 in 120, L4-L5 in 134, and L5-S1 in 6 patients. It was done at 1 level in 56, 2 levels in 107, and 3 levels in 16 patients. Surgery time and blood loss were, respectively, 32.5 ± 13.2 minutes and 57 ± 131 ml per level fused. There were 19 patients with a single complication and one with two complications, including two patients with postoperative radiculopathy after L3-5 OLIF. There was no abdominal weakness or herniation. Minimally invasive OLIF can be performed easily and safely in the lumbar spine from L2 to L5, and at L1-2 for selected cases. Up to 3 levels can be addressed through a 'sliding window'. It is associated with minimal blood loss and short operations, and with decreased risk of abdominal wall weakness or herniation.
2008-01-01
Randomly oriented short and low density conical carbon nanotubes (CNTs) were prepared on Si substrates by tubular microwave plasma enhanced chemical vapor deposition process at relatively low temperature (350–550 °C) by judiciously controlling the microwave power and growth time in C2H2 + NH3gas composition and Fe catalyst. Both length as well as density of the CNTs increased with increasing microwave power. CNTs consisted of regular conical compartments stacked in such a way that their outer diameter remained constant. Majority of the nanotubes had a sharp conical tip (5–20 nm) while its other side was either open or had a cone/pear-shaped catalyst particle. The CNTs were highly crystalline and had many open edges on the outer surface, particularly near the joints of the two compartments. These films showed excellent field emission characteristics. The best emission was observed for a medium density film with the lowest turn-on and threshold fields of 1.0 and 2.10 V/μm, respectively. It is suggested that not only CNT tip but open edges on the body also act as active emission sites in the randomly oriented geometry of such periodic structures.
MULTIWAVELENGTH OBSERVATIONS OF A PARTIALLY ERUPTIVE FILAMENT ON 2011 SEPTEMBER 8
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Q. M.; Ning, Z. J.; Zhou, T. H.
2015-05-20
In this paper, we report our multiwavelength observations of a partial filament eruption event in NOAA active region (AR) 11283 on 8 September 2011. A magnetic null point and the corresponding spine and separatrix surface are found in the AR. Beneath the null point, a sheared arcade supports the filament along the highly complex and fragmented polarity inversion line. After being activated, the sigmoidal filament erupted and split into two parts. The major part rose at speeds of 90–150 km s{sup −1} before reaching the maximum apparent height of ∼115 Mm. Afterward, it returned to the solar surface in amore » bumpy way at speeds of 20–80 km s{sup −1}. The rising and falling motions were clearly observed in the extreme-ultraviolet, UV, and Hα wavelengths. The failed eruption of the main part was associated with an M6.7 flare with a single hard X-ray source. The runaway part of the filament, however, separated from and rotated around the major part for ∼1 turn at the eastern leg before escaping from the corona, probably along large-scale open magnetic field lines. The ejection of the runaway part resulted in a very faint coronal mass ejection that propagated at an apparent speed of 214 km s{sup −1} in the outer corona. The filament eruption also triggered a transverse kink-mode oscillation of the adjacent coronal loops in the same AR. The amplitude and period of the oscillation were 1.6 Mm and 225 s. Our results are important for understanding the mechanisms of partial filament eruptions, and provide new constraints to theoretical models. The multiwavelength observations also shed light on space weather prediction.« less
Type III Solar Radio Burst Source Region Splitting due to a Quasi-separatrix Layer
NASA Astrophysics Data System (ADS)
McCauley, Patrick I.; Cairns, Iver H.; Morgan, John; Gibson, Sarah E.; Harding, James C.; Lonsdale, Colin; Oberoi, Divya
2017-12-01
We present low-frequency (80–240 MHz) radio imaging of type III solar radio bursts observed by the Murchison Widefield Array on 2015 September 21. The source region for each burst splits from one dominant component at higher frequencies into two increasingly separated components at lower frequencies. For channels below ∼132 MHz, the two components repetitively diverge at high speeds (0.1c–0.4c) along directions tangent to the limb, with each episode lasting just ∼2 s. We argue that both effects result from the strong magnetic field connectivity gradient that the burst-driving electron beams move into. Persistence mapping of extreme-ultraviolet jets observed by the Solar Dynamics Observatory reveals quasi-separatrix layers (QSLs) associated with coronal null points, including separatrix dome, spine, and curtain structures. Electrons are accelerated at the flare site toward an open QSL, where the beams follow diverging field lines to produce the source splitting, with larger separations at larger heights (lower frequencies). The splitting motion within individual frequency bands is interpreted as a projected time-of-flight effect, whereby electrons traveling along the outer field lines take slightly longer to excite emission at adjacent positions. Given this interpretation, we estimate an average beam speed of 0.2c. We also qualitatively describe the quiescent corona, noting in particular that a disk-center coronal hole transitions from being dark at higher frequencies to bright at lower frequencies, turning over around 120 MHz. These observations are compared to synthetic images based on the MHD algorithm outside a sphere (MAS) model, which we use to flux-calibrate the burst data.
Luk, Keith D K
2011-03-01
Prevention or correction of severe kyphotic deformity in addition to eradication of the infective focus has become the modern standard of management of tuberculosis of the spine. Circumferential excision of the kyphus is now technically feasible with the development of rigid pedicle screw fixation system and intraoperative spinal cord monitoring in the past two decades.
2014-08-01
an absorbable collagen sponge (ACS) is the FDA-approved device for clinical applications including lumbar spine fusion, open tibial fractures, and...fibrinogen on the morphological change of the CL hydrogels was observed. The hydrogel samples were incubated into PBS (pH 7.4) at 37°C for 1 day and... morphology was observed qualitatively using a Zeiss Axiovert 200 microscope (Carl Zeiss Microimaging, Thornwood, NY). Photomicrographs of cells
Spinal Epidural Haemangioma Associated with Extensive Gastrointestinal Haemangiomas
Cheng, L.T.E.; Lim, W.E.H.
2005-01-01
Summary A case of spinal epidural cavernous haemangioma associated with gastrointestinal haemangiomas is discussed. The patient was a young Chinese female presenting with chronic lower back pain. She had a history of extensive gastric and small bowel haemangiomas. Lumbar spine MRI showed a heterogeneously enhancing epidural mass infiltrating the paravertebral muscles. Open biopsy confirmed an epidural cavernous haemangioma. To our knowledge, an association between spinal epidural cavernous haemangiomas and gastrointestinal haemangiomas has not been reported. PMID:20584496
The relationship between PSD-95 clustering and spine stability in vivo.
Cane, Michele; Maco, Bohumil; Knott, Graham; Holtmaat, Anthony
2014-02-05
The appearance and disappearance of dendritic spines, accompanied by synapse formation and elimination may underlie the experience-dependent reorganization of cortical circuits. The exact temporal relationship between spine and synapse formation in vivo remains unclear, as does the extent to which synapse formation enhances the stability of newly formed spines and whether transient spines produce synapses. We used in utero electroporation of DsRedExpress- and eGFP-tagged postsynaptic density protein 95 (PSD-95) to investigate the relationship between spine and PSD stability in mouse neocortical L2/3 pyramidal cells in vivo. Similar to previous studies, spines and synapses appeared and disappeared, even in naive animals. Cytosolic spine volumes and PSD-95-eGFP levels in spines covaried over time, suggesting that the strength of many individual synapses continuously changes in the adult neocortex. The minority of newly formed spines acquired PSD-95-eGFP puncta. Spines that failed to acquire a PSD rarely survived for more than a day. Although PSD-95-eGFP accumulation was associated with increased spine lifetimes, most new spines with a PSD did not convert into persistent spines. This indicates that transient spines may serve to produce short-lived synaptic contacts. Persistent spines that were destined to disappear showed, on average, reduced PSD-95-eGFP levels well before the actual pruning event. Altogether, our data indicate that the PSD size relates to spine stability in vivo.
Mechanism of Cd2+-coordination during Slow Inactivation in Potassium Channels
Raghuraman, H.; Cordero-Morales, Julio F.; Jogini, Vishwanath; Pan, Albert C.; Kollewe, Astrid; Roux, Benoît; Perozo, Eduardo
2013-01-01
Summary In K+ channels, rearrangements of the pore outer-vestibule have been associated with C-type inactivation gating. Paradoxically, the crystal structure of Open/C-type inactivated KcsA suggest these movements to be modest in magnitude. Here, we show that under physiological conditions, the KcsA outer-vestibule undergoes relatively large dynamic rearrangements upon inactivation. External Cd2+ enhances the rate of C-type inactivation in an outer-vestibule cysteine mutant (Y82C) via metal-bridge formation. This effect is not present in a non-inactivating mutant (E71A/Y82C). Tandem dimer and tandem tetramer constructs of equivalent cysteine mutants in KcsA and Shaker K+ channels demonstrate that these Cd2+ metal bridges are formed only between adjacent subunits. This is well supported by molecular dynamics simulations. Based on the crystal structure of Cd2+-bound Y82C-KcsA in the closed state, together with EPR distance measurements in the KcsA outer-vestibule, we suggest that subunits must dynamically come in close proximity as the channels undergo inactivation. PMID:22771214
Burdgick, Steven Sebastian; Burns, James Lee
2002-01-01
A nozzle segment for a gas turbine includes inner and outer band portions and a vane extending between the band portions. The inner and outer band portions are each divided into first and second plenums separated by an impingement plate. Cooling steam is supplied to the first cavity for flow through the apertures to cool the outer nozzle wall. The steam flows through a leading edge cavity in the vane into the first cavity of the inner band portion for flow through apertures of the impingement plate to cool the inner nozzle wall. Spent cooling steam flows through a plurality of cavities in the vane, exiting through an exit chimney in the outer band. The exit chimney is secured at its inner end directly to the nozzle vane wall surrounding the exit cavities, to the margin of the impingement plate at a location intermediate the ends of the exit chimney and to margins of an opening through the cover whereby each joint is externally accessible for joint formation and for subsequent inspection.
Dendritic spines linearize the summation of excitatory potentials
Araya, Roberto; Eisenthal, Kenneth B.; Yuste, Rafael
2006-01-01
In mammalian cortex, most excitatory inputs occur on dendritic spines, avoiding dendritic shafts. Although spines biochemically isolate inputs, nonspiny neurons can also implement biochemical compartmentalization; so, it is possible that spines have an additional function. We have recently shown that the spine neck can filter membrane potentials going into and out of the spine. To investigate the potential function of this electrical filtering, we used two-photon uncaging of glutamate and compared the integration of electrical signals in spines vs. dendritic shafts from basal dendrites of mouse layer 5 pyramidal neurons. Uncaging potentials onto spines summed linearly, whereas potentials on dendritic shafts reduced each other's effect. Linear integration of spines was maintained regardless of the amplitude of the response, distance between spines (as close as <2 μm), distance of the spines to the soma, dendritic diameter, or spine neck length. Our findings indicate that spines serve as electrical isolators to prevent input interaction, and thus generate a linear arithmetic of excitatory inputs. Linear integration could be an essential feature of cortical and other spine-laden circuits. PMID:17132736
Dendritic spines linearize the summation of excitatory potentials.
Araya, Roberto; Eisenthal, Kenneth B; Yuste, Rafael
2006-12-05
In mammalian cortex, most excitatory inputs occur on dendritic spines, avoiding dendritic shafts. Although spines biochemically isolate inputs, nonspiny neurons can also implement biochemical compartmentalization; so, it is possible that spines have an additional function. We have recently shown that the spine neck can filter membrane potentials going into and out of the spine. To investigate the potential function of this electrical filtering, we used two-photon uncaging of glutamate and compared the integration of electrical signals in spines vs. dendritic shafts from basal dendrites of mouse layer 5 pyramidal neurons. Uncaging potentials onto spines summed linearly, whereas potentials on dendritic shafts reduced each other's effect. Linear integration of spines was maintained regardless of the amplitude of the response, distance between spines (as close as < 2 microm), distance of the spines to the soma, dendritic diameter, or spine neck length. Our findings indicate that spines serve as electrical isolators to prevent input interaction, and thus generate a linear arithmetic of excitatory inputs. Linear integration could be an essential feature of cortical and other spine-laden circuits.
Analysis of mortality in colorectal surgery in the Bi-National Colorectal Cancer Audit.
Teloken, Patrick Ely; Spilsbury, Katrina; Platell, Cameron
2016-06-01
In the last decade, there has been a significant increase in interest for public reporting of outcome data and performance comparison across institutions and surgeons. This study aims at comparing postoperative mortality after colorectal cancer surgery across units and individual consultants in Australia and New Zealand using funnel plots. The Bi-National Colorectal Cancer Audit database was used. Unadjusted and adjusted funnel plots of inpatient mortality were constructed. Risk adjustment was based upon multivariable logistic regression models using purposeful covariate selection. A total of 10 008 patients undergoing surgery for colorectal cancer from 56 surgical units and 90 consultants were identified. Overall inpatient mortality was 1.51%, corresponding to 1.1% for elective and 3.9% for urgent cases. Logistic regression identified age, American Society of Anesthesiologists score, urgent surgery and open surgery to be independently associated with inpatient mortality. Unadjusted and adjusted funnel plot analysis identified three (5.3%) units exceeding the inner limit and none exceeding the outer limit. Six (6.6%) consultants had inpatient mortality between the upper inner and outer limits and one (1.1%) between the inferior inner and outer limits. Upon adjustment, seven (7.7%) consultants had inpatient mortality between the inner and outer limit. Potential limitations of this study include: residual confounding being responsible for the association of open surgery and mortality; incomplete case-mix adjustment resulting in outlier identification; and bias towards inclusion of larger institutions. Mortality figures in Australia and New Zealand are comparable to recently reported international data. The vast majority of units and consultants are performing within the expected boundaries. © 2016 Royal Australasian College of Surgeons.
Sawada, Koichi; Kokeguchi, Susumu; Hongyo, Hiroshi; Sawada, Satoko; Miyamoto, Manabu; Maeda, Hiroshi; Nishimura, Fusanori; Takashiba, Shogo; Murayama, Yoji
1999-01-01
Subtractive hybridization was employed to isolate specific genes from virulent Porphyromonas gingivalis strains that are possibly related to abscess formation. The genomic DNA from the virulent strain P. gingivalis W83 was subtracted with DNA from the avirulent strain ATCC 33277. Three clones unique to strain W83 were isolated and sequenced. The cloned DNA fragments were 885, 369, and 132 bp and had slight homology with only Bacillus stearothermophilus IS5377, which is a putative transposase. The regions flanking the cloned DNA fragments were isolated and sequenced, and the gene structure around the clones was revealed. These three clones were located side-by-side in a gene reported as an outer membrane protein. The three clones interrupt the open reading frame of the outer membrane protein gene. This inserted DNA, consisting of three isolated clones, was designated IS1598, which was 1,396 bp (i.e., a 1,158-bp open reading frame) in length and was flanked by 16-bp terminal inverted repeats and a 9-bp duplicated target sequence. IS1598 was detected in P. gingivalis W83, W50, and FDC 381 by Southern hybridization. All three P. gingivalis strains have been shown to possess abscess-forming ability in animal models. However, IS1598 was not detected in avirulent strains of P. gingivalis, including ATCC 33277. The IS1598 may interrupt the synthesis of the outer membrane protein, resulting in changes in the structure of the bacterial outer membrane. The IS1598 isolated in this study is a novel insertion element which might be a specific marker for virulent P. gingivalis strains. PMID:10531208
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Jingzhi; Qian, Xinguo; Hu, Junbin
2010-11-03
The preproteins targeted to the mitochondria are transported through the translocase of the outer membrane complex. Tom70/Tom71 is a major surface receptor of the translocase of the outer membrane complex for mitochondrial preproteins. The preproteins are escorted to Tom70/Tom71 by molecular chaperones Hsp70 and Hsp90. Here we present the high resolution crystal structures of Tom71 and the protein complexes between Tom71 and the Hsp70/Hsp90 C terminus. The crystal structures indicate that Tom70/Tom71 may exhibit two distinct states. In the closed state, the N-terminal domain of Tom70/Tom71 partially blocks the preprotein-binding pocket. In the open state, the N-terminal domain moves away,more » and the preprotein-binding pocket is fully exposed. The complex formation between the C-terminal EEVD motif of Hsp70/Hsp90 and Tom71 could lock Tom71 in the open state where the preprotein-binding pocket of Tom71 is ready to receive preproteins. The interactions between Hsp70/Hsp90 and Tom71 N-terminal domain generate conformational changes that may increase the volume of the preprotein-binding pocket. The complex formation of Hsp70/Hsp90 and Tom71 also generates significant domain rearrangement within Tom71, which may position the preprotein-binding pocket closer to Hsp70/Hsp90 to facilitate the preprotein transfer from the molecular chaperone to Tom71. Therefore, molecular chaperone Hsp70/Hsp90 may function to prepare the mitochondrial outer membrane receptor Tom71 for preprotein loading.« less
The Root Cause of Post-Traumatic and Developmental Stress Disorder
2014-10-01
cortex = mOFCtx) involving mushroom spines, 2) Increased density of stubby spines, suggesting that some mature mushroom spines have regressed to a more...and a trend for decreased mushroom spine density in PTSD (BA11), consistent with animal models. A subset of mature mushroom spines appear to have...been partially replaced by stubby spines. Stubby spines are less sophisticated than mushroom spines because they do not have necks, where modulatory
The Root Cause of Post-traumatic and Developmental Stress Disorder
2015-10-01
mOFCtx) involving mushroom spines (Young et al., 2015), 2) Increased density of stubby spines, suggesting that some mature mushroom spines have...BA11 (mOFCtx) and a trend for decreased mushroom spine density in PTSD (BA11), consistent with animal models. A subset of mature mushroom spines...appear to have been partially replaced by stubby spines. Stubby spines are less sophisticated than mushroom spines because they do not have necks
Open MR imaging in spine surgery: experimental investigations and first clinical experiences.
Verheyden, P; Katscher, S; Schulz, T; Schmidt, F; Josten, C
1999-01-01
The latest open MRI technology allows to perform open and closed surgical procedures under real-time imaging. Before performing spinal trauma surgery preclinical examinations had to be done to evaluate the artifacts caused by the implants. The MRT presented is a prototype developed by GE. Two vertically positioned magnetic coils are installed in an operation theater. By that means two surgeons are able to access the patient between the two coils. Numerous tests regarding the material of instruments and implants were necessary in advance. The specific size of the artifact depending on the pulse sequence and the positioning within the magnetic field had to be examined. The magnifying factors of the artifact in the spin echo sequence regarding titanium are between 1.7 and 3.2, depending on the direction of the magnetic vector. Regarding stainless steel they are between 8.4 and 8.5. In the gradient echo sequence the factors are between 7.5 and 7.7 for titanium and between 16.9 and 18.0 for stainless steel. The tip of an implant is imaged with an accuracy of 0 to 2 mm. Since September 1997 16 patients with unstable fractures of the thoracic and lumbar spine have been treated by dorsal instrumentation in the open MRI. Percutaneous insertion of the internal fixator has proven a successful minimally invasive procedure. The positioning of the screws in the pedicle is secure, the degree of indirect reduction of the posterior wall of the vertebral body can be imaged immediately. The diameter of the spinal canal can be determined in any plane. The open MRI has proven useful in orthopedic and trauma surgery. The size and configuration of the artifacts caused by instruments and implants is predictable. Therefore exact positioning of the implants is achieved more easily. Dorsal instrumentation of unstable thoracolumbar fractures with a percutaneous technique has turned out safe and less traumatic under MR-imaging. Real-time imaging of soft tissue and bone in any plane improves security for the patient and allows the surgeon to work less invasively and more precisely.
Mummaneni, Praveen V; Shaffrey, Christopher I; Lenke, Lawrence G; Park, Paul; Wang, Michael Y; La Marca, Frank; Smith, Justin S; Mundis, Gregory M; Okonkwo, David O; Moal, Bertrand; Fessler, Richard G; Anand, Neel; Uribe, Juan S; Kanter, Adam S; Akbarnia, Behrooz; Fu, Kai-Ming G
2014-05-01
Minimally invasive surgery (MIS) is an alternative to open deformity surgery for the treatment of patients with adult spinal deformity. However, at this time MIS techniques are not as versatile as open deformity techniques, and MIS techniques have been reported to result in suboptimal sagittal plane correction or pseudarthrosis when used for severe deformities. The minimally invasive spinal deformity surgery (MISDEF) algorithm was created to provide a framework for rational decision making for surgeons who are considering MIS versus open spine surgery. A team of experienced spinal deformity surgeons developed the MISDEF algorithm that incorporates a patient's preoperative radiographic parameters and leads to one of 3 general plans ranging from MIS direct or indirect decompression to open deformity surgery with osteotomies. The authors surveyed fellowship-trained spine surgeons experienced with spinal deformity surgery to validate the algorithm using a set of 20 cases to establish interobserver reliability. They then resurveyed the same surgeons 2 months later with the same cases presented in a different sequence to establish intraobserver reliability. Responses were collected and tabulated. Fleiss' analysis was performed using MATLAB software. Over a 3-month period, 11 surgeons completed the surveys. Responses for MISDEF algorithm case review demonstrated an interobserver kappa of 0.58 for the first round of surveys and an interobserver kappa of 0.69 for the second round of surveys, consistent with substantial agreement. In at least 10 cases there was perfect agreement between the reviewing surgeons. The mean intraobserver kappa for the 2 surveys was 0.86 ± 0.15 (± SD) and ranged from 0.62 to 1. The use of the MISDEF algorithm provides consistent and straightforward guidance for surgeons who are considering either an MIS or an open approach for the treatment of patients with adult spinal deformity. The MISDEF algorithm was found to have substantial inter- and intraobserver agreement. Although further studies are needed, the application of this algorithm could provide a platform for surgeons to achieve the desired goals of surgery.
Open C2 Vertebroplasty: Case Report, Technique, and Review of Literature
Shetty, Sathwik Raviraj; Ganigi, Praveen Mahadev; Mandanna, Bopanna Kanjithanda
2017-01-01
Osteolytic lesions of C2 are challenging pathologies to manage. Vertebroplasty, a minimally invasive technique has been widely used in lytic lesions of thoracic and lumbar spine. However, there has been limited experience with percutaneous vertebroplasty at C2, and the procedure is technically difficult. We describe a safer alternative technique of open vertebroplasty for lytic lesions involving the axis. Methods: The procedure was performed in a 49-year-old male with a metastatic lytic lesion involving the body and dens of C2 using an anterior cervical approach. The patient had an immediate reduction in pain with complete pain relief at 2 weeks and good stability at 3-month follow-up. The patient did not have any perioperative or postoperative complications. The anterior cervical approach open C2 vertebroplasty is a safe and effective option in the management of C2 osteolytic lesions. PMID:29114290
Ten-Step Minimally Invasive Spine Lumbar Decompression and Dural Repair Through Tubular Retractors.
Boukebir, Mohamed Abdelatif; Berlin, Connor David; Navarro-Ramirez, Rodrigo; Heiland, Tim; Schöller, Karsten; Rawanduzy, Cameron; Kirnaz, Sertaç; Jada, Ajit; Härtl, Roger
2017-04-01
Minimally invasive spine (MIS) surgery utilizing tubular retractors has become an increasingly popular approach for decompression in the lumbar spine. However, a better understanding of appropriate indications, efficacious surgical techniques, limitations, and complication management is required to effectively teach the procedure and to facilitate the learning curve. To describe our experience and recommendations regarding tubular surgery for lumbar disc herniations, foraminal compression with unilateral radiculopathy, lumbar spinal stenosis, synovial cysts, and dural repair. We reviewed our experience between 2008 and 2014 to develop a step-by-step description of the surgical techniques and complication management, including dural repair through tubes, for the 4 lumbar pathologies of highest frequency. We provide additional supplementary videos for dural tear repair, laminotomy for bilateral decompression, and synovial cyst resection. Our overview and complementary materials document the key technical details to maximize the success of the 4 MIS surgical techniques. The review of our experience in 331 patients reveals technical feasibility as well as satisfying clinical results, with no postoperative complications associated with cerebrospinal fluid leaks, 1 infection, and 17 instances (5.1%) of delayed fusion. MIS surgery through tubular retractors is a safe and effective alternative to traditional open or microsurgical techniques for the treatment of lumbar degenerative disease. Adherence to strict microsurgical techniques will allow the surgeon to effectively address bilateral pathology while preserving stability and minimizing complications. Copyright © 2017 by the Congress of Neurological Surgeons
DeFaveri, Jacquelin; Merilä, Juha
2015-01-01
Temporal variation in allele frequencies, whether caused by deterministic or stochastic forces, can inform us about interesting demographic and evolutionary phenomena occurring in wild populations. In spite of the continued surge of interest in the genetics of three-spined stickleback (Gasterosteus aculeatus) populations, little attention has been paid towards the temporal stability of allele frequency distributions, and whether there are consistent differences in effective size (Ne) of local populations. We investigated temporal stability of genetic variability and differentiation in 15 microsatellite loci within and among eight collection sites of varying habitat type, surveyed twice over a six-year time period. In addition, Nes were estimated with the expectation that they would be lowest in isolated ponds, intermediate in larger lakes and largest in open marine sites. In spite of the marked differences in genetic variability and differentiation among the study sites, the temporal differences in allele frequencies, as well as measures of genetic diversity and differentiation, were negligible. Accordingly, the Ne estimates were temporally stable, but tended to be lower in ponds than in lake or marine habitats. Hence, we conclude that allele frequencies in putatively neutral markers in three-spined sticklebacks seem to be temporally stable – at least over periods of few generations – across a wide range of habitat types differing markedly in levels of genetic variability, effective population size and gene flow. PMID:25853707
DeFaveri, Jacquelin; Merilä, Juha
2015-01-01
Temporal variation in allele frequencies, whether caused by deterministic or stochastic forces, can inform us about interesting demographic and evolutionary phenomena occurring in wild populations. In spite of the continued surge of interest in the genetics of three-spined stickleback (Gasterosteus aculeatus) populations, little attention has been paid towards the temporal stability of allele frequency distributions, and whether there are consistent differences in effective size (Ne) of local populations. We investigated temporal stability of genetic variability and differentiation in 15 microsatellite loci within and among eight collection sites of varying habitat type, surveyed twice over a six-year time period. In addition, Nes were estimated with the expectation that they would be lowest in isolated ponds, intermediate in larger lakes and largest in open marine sites. In spite of the marked differences in genetic variability and differentiation among the study sites, the temporal differences in allele frequencies, as well as measures of genetic diversity and differentiation, were negligible. Accordingly, the Ne estimates were temporally stable, but tended to be lower in ponds than in lake or marine habitats. Hence, we conclude that allele frequencies in putatively neutral markers in three-spined sticklebacks seem to be temporally stable - at least over periods of few generations - across a wide range of habitat types differing markedly in levels of genetic variability, effective population size and gene flow.
Loss of PSD-95 Enrichment is not a Prerequisite for Spine Retraction
Woods, Georgia F.; Oh, Won Chan; Boudewyn, Lauren C.; Mikula, Sarah K.; Zito, Karen
2011-01-01
Changes in neuronal structure are thought to underlie long-term behavioral modifications associated with learning and memory. In particular, considerable evidence implicates the destabilization and retraction of dendritic spines along with the loss of spine synapses as an important cellular mechanism for refining brain circuits, yet the molecular mechanisms regulating spine elimination remain ill-defined. The postsynaptic density protein, PSD-95, is highly enriched in dendritic spines and has been associated with spine stability. Because spines with low levels of PSD-95 are more dynamic, and the recruitment of PSD-95 to nascent spines has been associated with spine stabilization, we hypothesized that loss of PSD-95 enrichment would be a prerequisite for spine retraction. To test this hypothesis, we used dual-color time-lapse two-photon microscopy to monitor rat hippocampal pyramidal neurons co-transfected with PSD-95-GFP and DsRed-Express, and we analyzed the relationship between PSD-95-GFP enrichment and spine morphological changes. Consistent with our hypothesis, we found that the majority of spines that retracted were relatively unenriched for PSD-95-GFP. However, in the subset of PSD-95-GFP-enriched spines that retracted, spine shrinkage and loss of PSD-95-GFP were tightly coupled, suggesting that loss of PSD-95-GFP enrichment did not precede spine retraction. Moreover, we found that in some instances spine retraction resulted in a significant enrichment of PSD-95-GFP on the dendritic shaft. Our data support a model of spine retraction in which loss of PSD-95 enrichment is not required prior to the destabilization of spines. PMID:21865455
Apparatus for observing a hostile environment
Nance, Thomas A.; Boylston, Micah L.; Robinson, Casandra W.; Sexton, William C.; Heckendorn, Frank M.
2000-01-01
An apparatus is provided for observing a hostile environment, comprising a housing and a camera capable of insertion within the housing. The housing is a double wall assembly with an inner and outer wall with an hermetically sealed chamber therebetween. A housing for an optical system used to observe a hostile environment is provided, comprising a transparent, double wall assembly. The double wall assembly has an inner wall and an outer wall with an hermetically sealed chamber therebetween. The double wall assembly has an opening and a void area in communication with the opening. The void area of the housing is adapted to accommodate the optical system within said void area. An apparatus for protecting an optical system used to observe a hostile environment is provided comprising a housing; a tube positioned within the housing; and a base for supporting the housing and the tube. The housing comprises a double wall assembly having an inner wall and an outerwall with an hermetically sealed chamber therebetween. The tube is adapted to house the optical system therein.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J
A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from themore » liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.« less
Active bypass flow control for a seal in a gas turbine engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebert, Todd A.; Kimmel, Keith D.
An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wears.more » In at least one embodiment, the metering device may include a valve formed from one or more pins movable between open and closed positions in which the one pin at least partially bisects the bypass channel to regulate flow.« less
Helmet of a laminate construction of polycarbonate and polysulfone polymeric material
NASA Technical Reports Server (NTRS)
Kosmo, Joseph J. (Inventor); Dawn, Frederic S. (Inventor)
1991-01-01
An article of laminate construction is disclosed which is comprised of an underlayer of polycarbonate polymer material to which is applied a chemically resistant outer layer of polysulfone. The layers which are joined by compression-heat molding, are molded to form the shape of a body protective shell such as a space helmet comprising a shell of polycarbonate, polysulfone laminate construction attached at its open end to a sealing ring adapted for connection to a space suit. The front portion of the shell provides a transparent visor for the helmet. An outer visor of polycarbonate polysulfone laminate construction is pivotally mounted to the sealing ring for covering the transparent visor portion of the shell during extravehicular activities. The polycarbonate under layer of the outer visor is coated on its inner surface with a vacuum deposit of gold to provide additional thermal radiation resistance.
Yuk, Frank; Steinberger, Jeremy; Skovrlj, Branko; Mascitelli, Justin; Cho, Samuel K; Caridi, John M
2017-11-01
Spine surgery relies heavily on technology and surgical instrumentation. Improperly used instrumentation can be detrimental to the patient. Despite multiple checkpoints to ensure that foreign bodies are not retained in surgery, numerous case reports have described retained foreign bodies; however, none of these cases involve retained instrumentation after open spine surgery. Of the retained objects, 4 were sponges and one was a Jamshidi needle fragment. Although smaller objects are more commonly the culprits, surgical instruments can break off, remain stuck, and cause clinical sequelae. This case presents a retained fractured pedicle finder as the cause of right L5 radiculopathy. To our knowledge, this report is the first to describe an instrumentation-associated postoperative radiculopathy. Because of the strength with which the object was impacted, its extraction proved difficult. The technique of removal using a mallet and osteotome in 4 directions to loosen its hold in the vertebral body. Attempts and eventual successful removal are described. Copyright © 2017 Elsevier Inc. All rights reserved.
Design and Control of Modular Spine-Like Tensegrity Structures
NASA Technical Reports Server (NTRS)
Mirletz, Brian T.; Park, In-Won; Flemons, Thomas E.; Agogino, Adrian K.; Quinn, Roger D.; SunSpiral, Vytas
2014-01-01
We present a methodology enabled by the NASA Tensegrity Robotics Toolkit (NTRT) for the rapid structural design of tensegrity robots in simulation and an approach for developing control systems using central pattern generators, local impedance controllers, and parameter optimization techniques to determine effective locomotion strategies for the robot. Biomimetic tensegrity structures provide advantageous properties to robotic locomotion and manipulation tasks, such as their adaptability and force distribution properties, flexibility, energy efficiency, and access to extreme terrains. While strides have been made in designing insightful static biotensegrity structures, gaining a clear understanding of how a particular structure can efficiently move has been an open problem. The tools in the NTRT enable the rapid exploration of the dynamics of a given morphology, and the links between structure, controllability, and resulting gait efficiency. To highlight the effectiveness of the NTRT at this exploration of morphology and control, we will provide examples from the designs and locomotion of four different modular spine-like tensegrity robots.
Klippel-Feil syndrome plus atretic meningocele in one identical twin and anencephaly in the other.
Chan, Pei-Chun; Hsieh, Wu-Shiun; Peng, Steven S F
2003-07-01
Klippel-Feil syndrome (KFS) is a heterogeneous entity, characterized by specific congenital anomalies of segmentation of the cervical spine. We report a case of KFS plus atretic meningocele in one identical twin and anencephaly in the other. These identical twins were both male with no chromosome defect. One of them had anencephaly diagnosed at the gestational age of 17 weeks and died soon after birth, whereas the co-twin had KFS with multiple congenital anomalies including short neck with low hairline, occipital atretic meningocele, butterfly vertebrae, hemivertebrae, cervico-thoracic scoliosis, left thumb preaxial polydactyly, and right undescended testis. He received rehabilitation during infancy and could walk at the age of 15 months. Both of these infants had preaxial polydactyly, which is an uncommon anomaly associated with KFS. In conclusion, iniencephaly and anencephaly are probably the extreme manifestations of KFS rather than different dysraphisms. Prompt clinical suspicion with early diagnostic imaging for spine lesions and occult opening of neural tube is mandatory for further intervention and rehabilitation.
Arthroscopic Management of Tibial Spine Avulsion Fractures: Principles and Techniques.
Strauss, Eric J; Kaplan, Daniel James; Weinberg, Maxwell E; Egol, Jonathan; Jazrawi, Laith M
2018-05-15
Tibial spine fractures are uncommon injuries affecting the insertion of the anterior cruciate ligament on the tibia. They typically occur in skeletally immature patients aged 8 to 14 years and result from hyperextension of the knee with a valgus or rotational force. Diagnosis is based on history, physical examination, and standard radiographs. The use of MRI can identify entrapped soft tissue that may prevent reduction. Open or arthroscopic repair is indicated in patients with partially displaced fractures (>5 mm) with one third to one half of the avulsed fragment elevated, in patients who have undergone unsuccessful nonsurgical reduction and long leg casting or bracing, and in patients with completely displaced fractures. Arthroscopy offers reduced invasiveness and decreased morbidity. Suture fixation and screw fixation have produced successful results. Suture fixation can eliminate the risk of fracture fragment comminution during screw insertion, the risk of neurovascular injury, and the need for hardware removal. Suture fixation is ideal in cases in which existing comminution prevents screw fixation.
The nerve supply of the lumbar intervertebral disc.
Edgar, M A
2007-09-01
The anatomical studies, basic to our understanding of lumbar spine innervation through the sinu-vertebral nerves, are reviewed. Research in the 1980s suggested that pain sensation was conducted in part via the sympathetic system. These sensory pathways have now been clarified using sophisticated experimental and histochemical techniques confirming a dual pattern. One route enters the adjacent dorsal root segmentally, whereas the other supply is non-segmental ascending through the paravertebral sympathetic chain with re-entry through the thoracolumbar white rami communicantes. Sensory nerve endings in the degenerative lumbar disc penetrate deep into the disrupted nucleus pulposus, insensitive in the normal lumbar spine. Complex as well as free nerve endings would appear to contribute to pain transmission. The nature and mechanism of discogenic pain is still speculative but there is growing evidence to support a 'visceral pain' hypothesis, unique in the muscloskeletal system. This mechanism is open to 'peripheral sensitisation' and possibly 'central sensitisation' as a potential cause of chronic back pain.
Spontaneous rise in open rectangular channels under gravity.
Thammanna Gurumurthy, Vignesh; Roisman, Ilia V; Tropea, Cameron; Garoff, Stephen
2018-05-17
Fluid movement in microfluidic devices, porous media, and textured surfaces involves coupled flows over the faces and corners of the media. Spontaneous wetting of simple grooved surfaces provides a model system to probe these flows. This numerical study investigates the spontaneous rise of a liquid in an array of open rectangular channels under gravity, using the Volume-of-Fluid method with adaptive mesh refinement. The rise is characterized by the meniscus height at the channel center, outer face and the interior and exterior corners. At lower contact angles and higher channel aspect ratios, the statics and dynamics of the rise in the channel center show little deviation with the classical model for capillarity, which ignores the existence of corners. For contact angles smaller than 45°, rivulets are formed in the interior corners and a cusp at the exterior corner. The rivulets at long times obey the one-third power law in time, with a weak dependence on the geometry. The cusp behaviour at the exterior corner transforms into a smooth meniscus when the capillary force is higher in the channel, even for contact angles smaller than 45°. The width of the outer face does not influence the capillary rise inside the channel, and the channel size does not influence the rise on the outer face. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chen, Qi; Huang, Shenghai; Ma, Qingkai; Lin, Huiling; Pan, Mengmeng; Liu, Xinting; Lu, Fan; Shen, Meixiao
2017-02-01
The structural characteristics of the outer retinal layers in primary open angle glaucoma (POAG) are still controversial, and these changes, along with those in the inner retinal layers, could have clinical and/or pathophysiological significance. A custom-built ultra-high resolution optical coherence tomography (UHR-OCT) combined with an automated segmentation algorithm can image and measure the eight intra-retinal layers. The purpose of this study is to determine the thickness characteristics of the macular intra-retinal layers, especially the outer layers, in POAG patients. Thirty-four POAG patients (56 eyes) and 33 normal subjects (63 eyes) were enrolled. Thickness profiles of the eight intra-retinal layers along a 6-mm length centred on the fovea at the horizontal and vertical meridians were obtained and the regional thicknesses were compared between two groups. The associations between the thicknesses of each intra-retinal layer and the macular visual field (VF) sensitivity were then analysed. POAG affected not only the inner retinal layers but also the photoreceptor layers and retinal pigment epithelium of the outer retina. However, the VF loss was correlated mainly with the damage of the inner retinal layers. UHR-OCT with automated algorithm is a useful tool in detecting microstructural changes of macula with respect to the progression of glaucoma.
NASA Astrophysics Data System (ADS)
Vinš, Václav; Hošek, Jan; Hykl, Jiří; Hrubý, Jan
2015-05-01
New experimental apparatus for measurement of the surface tension of liquids under the metastable supercooled state has been designed and assembled in the study. The measuring technique is similar to the method employed by P.T. Hacker [NACA TN 2510] in 1951. A short liquid thread of the liquid sample was sucked inside a horizontal capillary tube partly placed in a temperature-controlled glass chamber. One end of the capillary tube was connected to a setup with inert gas which allowed for precise tuning of the gas overpressure in order of hundreds of Pa. The open end of the capillary tube was precisely grinded and polished before the measurement in order to assure planarity and perpendicularity of the outer surface. The liquid meniscus at the open end was illuminated by a laser beam and observed by a digital camera. Application of an increasing overpressure of the inert gas at the inner meniscus of the liquid thread caused variation of the outer meniscus such that it gradually changed from concave to flat and subsequently convex shape. The surface tension at the temperature of the inner meniscus could be evaluated from the overpressure corresponding to exactly planar outer meniscus. Detailed description of the new setup together with results of the preliminary tests is provided in the study.
The Origins of U.S. Space Policy: Eisenhower, Open Skies, and Freedom of Space.
1992-01-01
national security, the executive action that shaped this enterprise and the space policy that President Dwight D. Eisenhower and his advisors created for...program, the president’s closest advisors determined, if at all possible, to keep outer space a region open to all, where the spacecraft of any state...83. The NSC Planning Board, also at the president’s direction, in November 1954 had established a net capabilities evaluation subcommittee" that
Collar spine models in the genus Echinostoma (Trematoda: Echinostomatidae).
Kanev, Ivan; Fried, Bernard; Radev, Valentin
2009-10-01
This paper discusses collar spine arrangements in the genus Echinostoma. All arrangements are of uneven numbers of collar spines on the oral collar. The total number of collar spines in these arrangements ranges from a low 31 to a high 51. There are 11 models of collar spine arrangements in the Echinostoma consisting of spine numbers 31, 33, 35, 37, 39, 41, 43, 45, 47, 49, and 51. Representative species with these collar spine arrangements are given in the article. The number of collar spines in a species is identical in both the larval and adult forms. Reports of even numbered spine counts in the genus Echinostoma are erroneous and probably reflect counts on worms with lost, retracted, or supernumerary spines.
Sarabia-Estrada, Rachel; Ruiz-Valls, Alejandro; Shah, Sagar R; Ahmed, A Karim; Ordonez, Alvaro A; Rodriguez, Fausto J; Guerrero-Cazares, Hugo; Jimenez-Estrada, Ismael; Velarde, Esteban; Tyler, Betty; Li, Yuxin; Phillips, Neil A; Goodwin, C Rory; Petteys, Rory J; Jain, Sanjay K; Gallia, Gary L; Gokaslan, Ziya L; Quinones-Hinojosa, Alfredo; Sciubba, Daniel M
2017-08-01
OBJECTIVE Chordoma is a slow-growing, locally aggressive cancer that is minimally responsive to conventional chemotherapy and radiotherapy and has high local recurrence rates after resection. Currently, there are no rodent models of spinal chordoma. In the present study, the authors sought to develop and characterize an orthotopic model of human chordoma in an immunocompromised rat. METHODS Thirty-four immunocompromised rats were randomly allocated to 4 study groups; 22 of the 34 rats were engrafted in the lumbar spine with human chordoma. The groups were as follows: UCH1 tumor-engrafted (n = 11), JHC7 tumor-engrafted (n = 11), sham surgery (n = 6), and intact control (n = 6) rats. Neurological impairment of rats due to tumor growth was evaluated using open field and locomotion gait analysis; pain response was evaluated using mechanical or thermal paw stimulation. Cone beam CT (CBCT), MRI, and nanoScan PET/CT were performed to evaluate bony changes due to tumor growth. On Day 550, rats were killed and spines were processed for H & E-based histological examination and immunohistochemistry for brachyury, S100β, and cytokeratin. RESULTS The spine tumors displayed typical chordoma morphology, that is, physaliferous cells filled with vacuolated cytoplasm of mucoid matrix. Brachyury immunoreactivity was confirmed by immunostaining, in which samples from tumor-engrafted rats showed a strong nuclear signal. Sclerotic lesions in the vertebral body of rats in the UCH1 and JHC7 groups were observed on CBCT. Tumor growth was confirmed using contrast-enhanced MRI. In UCH1 rats, large tumors were observed growing from the vertebral body. JHC7 chordoma-engrafted rats showed smaller tumors confined to the bone periphery compared with UCH1 chordoma-engrafted rats. Locomotion analysis showed a disruption in the normal gait pattern, with an increase in the step length and duration of the gait in tumor-engrafted rats. The distance traveled and the speed of rats in the open field test was significantly reduced in the UCH1 and JHC7 tumor-engrafted rats compared with controls. Nociceptive response to a mechanical stimulus showed a significant (p < 0.001) increase in the paw withdrawal threshold (mechanical hypalgesia). In contrast, the paw withdrawal response to a thermal stimulus decreased significantly (p < 0.05) in tumor-engrafted rats. CONCLUSIONS The authors developed an orthotopic human chordoma model in rats. Rats were followed for 550 days using imaging techniques, including MRI, CBCT, and nanoScan PET/CT, to evaluate lesion progression and bony integrity. Nociceptive evaluations and locomotion analysis were performed during follow-up. This model reproduces cardinal signs, such as locomotor and sensory deficits, similar to those observed clinically in human patients. To the authors' knowledge, this is the first spine rodent model of human chordoma. Its use and further study will be essential for pathophysiology research and the development of new therapeutic strategies.
Biophysical model of the role of actin remodeling on dendritic spine morphology
Miermans, C. A.; Kusters, R. P. T.; Hoogenraad, C. C.; Storm, C.
2017-01-01
Dendritic spines are small membranous structures that protrude from the neuronal dendrite. Each spine contains a synaptic contact site that may connect its parent dendrite to the axons of neighboring neurons. Dendritic spines are markedly distinct in shape and size, and certain types of stimulation prompt spines to evolve, in fairly predictable fashion, from thin nascent morphologies to the mushroom-like shapes associated with mature spines. It is well established that the remodeling of spines is strongly dependent upon the actin cytoskeleton inside the spine. A general framework that details the precise role of actin in directing the transitions between the various spine shapes is lacking. We address this issue, and present a quantitative, model-based scenario for spine plasticity validated using realistic and physiologically relevant parameters. Our model points to a crucial role for the actin cytoskeleton. In the early stages of spine formation, the interplay between the elastic properties of the spine membrane and the protrusive forces generated in the actin cytoskeleton propels the incipient spine. In the maturation stage, actin remodeling in the form of the combined dynamics of branched and bundled actin is required to form mature, mushroom-like spines. Importantly, our model shows that constricting the spine-neck aids in the stabilization of mature spines, thus pointing to a role in stabilization and maintenance for additional factors such as ring-like F-actin structures. Taken together, our model provides unique insights into the fundamental role of actin remodeling and polymerization forces during spine formation and maturation. PMID:28158194
Bedini, Emiliano; Cirillo, Luigi; Parrilli, Michelangelo
2012-02-15
The synthesis of β-Gal-(1→3)-α-GalNAc-(1→3)-β-GalNAc allyl trisaccharide as the outer core fragment of Burkholderia cepacia pv. vietnamiensis lipooligosaccharide was accomplished through a concise, optimized, multi-step synthesis, having as key steps three glycosylations, that were in-depth studied performing them under several conditions. The target trisaccharide was designed with an allyl aglycone in order to open a future access to the conjugation with an immunogenic protein en route to the development of a synthetic neoglycoconjugate vaccine against this Burkholderia pathogen. Copyright © 2011 Elsevier Ltd. All rights reserved.
Zoology: A New Mouth for Amphioxus.
Soukup, Vladimir; Kozmik, Zbynek
2016-05-09
Deuterostomes - a key subdivision of animals - are characterized by the mouth developing anteriorly as a rupture between the outer epithelium and the foregut wall. A new study of amphioxus challenges this view and proposes separate evolutionary origins of deuterostome oral openings. Copyright © 2016 Elsevier Ltd. All rights reserved.
miR-132, an experience-dependent microRNA, is essential for visual cortex plasticity
Mellios, Nikolaos; Sugihara, Hiroki; Castro, Jorge; Banerjee, Abhishek; Le, Chuong; Kumar, Arooshi; Crawford, Benjamin; Strathmann, Julia; Tropea, Daniela; Levine, Stuart S.; Edbauer, Dieter; Sur, Mriganka
2011-01-01
Using multiple quantitative analyses, we discovered microRNAs (miRNAs) abundantly expressed in visual cortex that respond to dark-rearing (DR) and/or monocular deprivation (MD). The most significantly altered miRNA, miR-132, was rapidly upregulated after eye-opening and delayed by DR. In vivo inhibition of miR-132 prevented ocular dominance plasticity in identified neurons following MD, and affected maturation of dendritic spines, demonstrating its critical role in the plasticity of visual cortex circuits. PMID:21892155
Dendritic spine dynamics leading to spine elimination after repeated inductions of LTD
Hasegawa, Sho; Sakuragi, Shigeo; Tominaga-Yoshino, Keiko; Ogura, Akihiko
2015-01-01
Memory is fixed solidly by repetition. However, the cellular mechanism underlying this repetition-dependent memory consolidation/reconsolidation remains unclear. In our previous study using stable slice cultures of the rodent hippocampus, we found long-lasting synaptic enhancement/suppression coupled with synapse formation/elimination after repeated inductions of chemical LTP/LTD, respectively. We proposed these phenomena as useful model systems for analyzing repetition-dependent memory consolidation. Recently, we analyzed the dynamics of dendritic spines during development of the enhancement, and found that the spines increased in number following characteristic stochastic processes. The current study investigates spine dynamics during the development of the suppression. We found that the rate of spine retraction increased immediately leaving that of spine generation unaltered. Spine elimination occurred independent of the pre-existing spine density on the dendritic segment. In terms of elimination, mushroom-type spines were not necessarily more stable than stubby-type and thin-type spines. PMID:25573377
A model of activity-dependent changes in dendritic spine density and spine structure.
Crook, S M; Dur-E-Ahmad, M; Baer, S M
2007-10-01
Recent evidence indicates that the morphology and density of dendritic spines are regulated during synaptic plasticity. See, for instance, a review by Hayashi and Majewska [9]. In this work, we extend previous modeling studies [27] by combining a model for activity-dependent spine density with one for calcium-mediated spine stem restructuring. The model is based on the standard dimensionless cable equation, which represents the change in the membrane potential in a passive dendrite. Additional equations characterize the change in spine density along the dendrite, the current balance equation for an individual spine head, the change in calcium concentration in the spine head, and the dynamics of spine stem resistance. We use computational studies to investigate the changes in spine density and structure for differing synaptic inputs and demonstrate the effects of these changes on the input-output properties of the dendritic branch. Moderate amounts of high-frequency synaptic activation to dendritic spines result in an increase in spine stem resistance that is correlated with spine stem elongation. In addition, the spine density increases both inside and outside the input region. The model is formulated so that this long-term potentiation-inducing stimulus eventually leads to structural stability. In contrast, a prolonged low-frequency stimulation paradigm that would typically induce long-term depression results in a decrease in stem resistance (correlated with stem shortening) and an eventual decrease in spine density.
Ultrastructure of Dendritic Spines: Correlation Between Synaptic and Spine Morphologies
Arellano, Jon I.; Benavides-Piccione, Ruth; DeFelipe, Javier; Yuste, Rafael
2007-01-01
Dendritic spines are critical elements of cortical circuits, since they establish most excitatory synapses. Recent studies have reported correlations between morphological and functional parameters of spines. Specifically, the spine head volume is correlated with the area of the postsynaptic density (PSD), the number of postsynaptic receptors and the ready-releasable pool of transmitter, whereas the length of the spine neck is proportional to the degree of biochemical and electrical isolation of the spine from its parent dendrite. Therefore, the morphology of a spine could determine its synaptic strength and learning rules. To better understand the natural variability of neocortical spine morphologies, we used a combination of gold-toned Golgi impregnations and serial thin-section electron microscopy and performed three-dimensional reconstructions of spines from layer 2/3 pyramidal cells from mouse visual cortex. We characterized the structure and synaptic features of 144 completed reconstructed spines, and analyzed their morphologies according to their positions. For all morphological parameters analyzed, spines exhibited a continuum of variability, without clearly distinguishable subtypes of spines or clear dependence of their morphologies on their distance to the soma. On average, the spine head volume was correlated strongly with PSD area and weakly with neck diameter, but not with neck length. The large morphological diversity suggests an equally large variability of synaptic strength and learning rules. PMID:18982124
Diversity of Spine Synapses in Animals
Wang, Ya-Xian; Mattson, Mark P.; Yao, Pamela J.
2016-01-01
Here we examine the structure of the various types of spine synapses throughout the animal kingdom. Based on available evidence, we suggest that there are two major categories of spine synapses: invaginating and non-invaginating, with distributions that vary among different groups of animals. In the simplest living animals with definitive nerve cells and synapses, the cnidarians and ctenophores, most chemical synapses do not form spine synapses. But some cnidarians have invaginating spine synapses, especially in photoreceptor terminals of motile cnidarians with highly complex visual organs, and also in some mainly sessile cnidarians with rapid prey capture reflexes. This association of invaginating spine synapses with complex sensory inputs is retained in the evolution of higher animals in photoreceptor terminals and some mechanoreceptor synapses. In contrast to invaginating spine synapse, non-invaginating spine synapses have been described only in animals with bilateral symmetry, heads and brains, associated with greater complexity in neural connections. This is apparent already in the simplest bilaterians, the flatworms, which can have well-developed non-invaginating spine synapses in some cases. Non-invaginating spine synapses diversify in higher animal groups. We also discuss the functional advantages of having synapses on spines and more specifically, on invaginating spines. And finally we discuss pathologies associated with spine synapses, concentrating on those systems and diseases where invaginating spine synapses are involved. PMID:27230661
Wen, Han; Qin, Feng; Zheng, Wenjun
2016-12-01
As a key cellular sensor, the TRPV1 cation channel undergoes a gating transition from a closed state to an open state in response to various physical and chemical stimuli including noxious heat. Despite years of study, the heat activation mechanism of TRPV1 gating remains enigmatic at the molecular level. Toward elucidating the structural and energetic basis of TRPV1 gating, we have performed molecular dynamics (MD) simulations (with cumulative simulation time of 3 μs), starting from the high-resolution closed and open structures of TRPV1 solved by cryo-electron microscopy. In the closed-state simulations at 30°C, we observed a stably closed channel constricted at the lower gate (near residue I679), while the upper gate (near residues G643 and M644) is dynamic and undergoes flickery opening/closing. In the open-state simulations at 60°C, we found higher conformational variation consistent with a large entropy increase required for the heat activation, and both the lower and upper gates are dynamic with transient opening/closing. Through ensemble-based structural analyses of the closed state versus the open state, we revealed pronounced closed-to-open conformational changes involving the membrane proximal domain (MPD) linker, the outer pore, and the TRP helix, which are accompanied by breaking/forming of a network of closed/open-state specific hydrogen bonds. By comparing the closed-state simulations at 30°C and 60°C, we observed heat-activated conformational changes in the MPD linker, the outer pore, and the TRP helix that resemble the closed-to-open conformational changes, along with partial formation of the open-state specific hydrogen bonds. Some of the residues involved in the above key hydrogen bonds were validated by previous mutational studies. Taken together, our MD simulations have offered rich structural and dynamic details beyond the static structures of TRPV1, and promising targets for future mutagenesis and functional studies of the TRPV1 channel. Proteins 2016; 84:1938-1949. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Computed Tomography (CT) - Spine
... Resources Professions Site Index A-Z Computed Tomography (CT) - Spine Computed tomography (CT) of the spine is ... of CT Scanning of the Spine? What is CT Scanning of the Spine? Computed tomography, more commonly ...
The spine neck filters membrane potentials.
Araya, Roberto; Jiang, Jiang; Eisenthal, Kenneth B; Yuste, Rafael
2006-11-21
Dendritic spines receive most synaptic inputs in the forebrain. Their morphology, with a spine head isolated from the dendrite by a slender neck, indicates a potential role in isolating inputs. Indeed, biochemical compartmentalization occurs at spine heads because of the diffusional bottleneck created by the spine neck. Here we investigate whether the spine neck also isolates inputs electrically. Using two-photon uncaging of glutamate on spine heads from mouse layer-5 neocortical pyramidal cells, we find that the amplitude of uncaging potentials at the soma is inversely proportional to neck length. This effect is strong and independent of the position of the spine in the dendritic tree and size of the spine head. Moreover, spines with long necks are electrically silent at the soma, although their heads are activated by the uncaging event, as determined with calcium imaging. Finally, second harmonic measurements of membrane potential reveal an attenuation of somatic voltages into the spine head, an attenuation directly proportional to neck length. We conclude that the spine neck plays an electrical role in the transmission of membrane potentials, isolating synapses electrically.
The spine neck filters membrane potentials
Araya, Roberto; Jiang, Jiang; Eisenthal, Kenneth B.; Yuste, Rafael
2006-01-01
Dendritic spines receive most synaptic inputs in the forebrain. Their morphology, with a spine head isolated from the dendrite by a slender neck, indicates a potential role in isolating inputs. Indeed, biochemical compartmentalization occurs at spine heads because of the diffusional bottleneck created by the spine neck. Here we investigate whether the spine neck also isolates inputs electrically. Using two-photon uncaging of glutamate on spine heads from mouse layer-5 neocortical pyramidal cells, we find that the amplitude of uncaging potentials at the soma is inversely proportional to neck length. This effect is strong and independent of the position of the spine in the dendritic tree and size of the spine head. Moreover, spines with long necks are electrically silent at the soma, although their heads are activated by the uncaging event, as determined with calcium imaging. Finally, second harmonic measurements of membrane potential reveal an attenuation of somatic voltages into the spine head, an attenuation directly proportional to neck length. We conclude that the spine neck plays an electrical role in the transmission of membrane potentials, isolating synapses electrically. PMID:17093040
Electrical and Ca2+ signaling in dendritic spines of substantia nigra dopaminergic neurons
Hage, Travis A; Sun, Yujie; Khaliq, Zayd M
2016-01-01
Little is known about the density and function of dendritic spines on midbrain dopamine neurons, or the relative contribution of spine and shaft synapses to excitability. Using Ca2+ imaging, glutamate uncaging, fluorescence recovery after photobleaching and transgenic mice expressing labeled PSD-95, we comparatively analyzed electrical and Ca2+ signaling in spines and shaft synapses of dopamine neurons. Dendritic spines were present on dopaminergic neurons at low densities in live and fixed tissue. Uncaging-evoked potential amplitudes correlated inversely with spine length but positively with the presence of PSD-95. Spine Ca2+ signals were less sensitive to hyperpolarization than shaft synapses, suggesting amplification of spine head voltages. Lastly, activating spines during pacemaking, we observed an unexpected enhancement of spine Ca2+ midway throughout the spike cycle, likely involving recruitment of NMDA receptors and voltage-gated conductances. These results demonstrate functionality of spines in dopamine neurons and reveal a novel modulation of spine Ca2+ signaling during pacemaking. DOI: http://dx.doi.org/10.7554/eLife.13905.001 PMID:27163179
Amundsen, CR; Gjøen, HM; Larsen, B; Egeland, ES
2015-01-01
Reports on reddish carotenoid-based ornaments in female three-spined sticklebacks (Gasterosteus aculeatus) are few, despite the large interest in the species’ behaviour, ornamentation, morphology and evolution. We sampled sticklebacks from 17 sites in north-western Europe in this first extensive study on the occurrence of carotenoid-based female pelvic spines and throat ornaments. The field results showed that females, and males, with reddish spines were found in all 17 populations. Specimens of both sexes with conspicuous red spines were found in several of the sites. The pelvic spines of males were more intensely red compared to the females’ spines, and large specimens were more red than small ones. Fish infected with the tapeworm (Schistocephalus solidus) had drabber spines than uninfected fish. Both sexes had red spines both during and after the spawning period, but the intensity of the red colour was more exaggerated during the spawning period. As opposed to pelvic spines, no sign of red colour at the throat was observed in any female from any of the 17 populations. A rearing experiment was carried out to estimate a potential genetic component of the pelvic spine ornament by artificial crossing and rearing of 15 family groups during a 12 months period. The results indicated that the genetic component of the red colour at the spines was low or close to zero. Although reddish pelvic spines seem common in populations of stickleback, the potential adaptive function of the reddish pelvic spines remains largely unexplained. PMID:25861558
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J.
A system for sampling a sample material includes a probe which can have an outer probe housing with an open end. A liquid supply conduit within the housing has an outlet positioned to deliver liquid to the open end of the housing. The liquid supply conduit can be connectable to a liquid supply for delivering liquid at a first volumetric flow rate to the open end of the housing. A liquid exhaust conduit within the housing is provided for removing liquid from the open end of the housing. A liquid exhaust system can be provided for removing liquid from themore » liquid exhaust conduit at a second volumetric flow rate, the first volumetric flow rate exceeding the second volumetric flow rate, wherein liquid at the open end will receive sample, liquid containing sample material will be drawn into and through the liquid exhaust conduit, and liquid will overflow from the open end.« less
Code of Federal Regulations, 2014 CFR
2014-07-01
... program to control air pollution from outer continental shelf sources, under section 328 of the Act; (12... other functionally-equivalent opening. General permit means a part 70 permit that meets the requirements of § 70.6(d). Major source means any stationary source (or any group of stationary sources that are...
Code of Federal Regulations, 2011 CFR
2011-07-01
... program to control air pollution from outer continental shelf sources, under section 328 of the Act; (12... other functionally-equivalent opening. General permit means a part 70 permit that meets the requirements of § 70.6(d). Major source means any stationary source (or any group of stationary sources that are...
Code of Federal Regulations, 2013 CFR
2013-07-01
... program to control air pollution from outer continental shelf sources, under section 328 of the Act; (12... other functionally-equivalent opening. General permit means a part 70 permit that meets the requirements of § 70.6(d). Major source means any stationary source (or any group of stationary sources that are...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-19
...), Interior. ACTION: Notice of the availability of Environmental Assessment (EA) and Finding of No Significant... that implement the National Environmental Policy Act (NEPA), announces the availability of two... 2010 open-water period. Shell's proposal includes suspending all operations and removal of the drill...
30 CFR 291.107 - How do I answer a complaint?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false How do I answer a complaint? 291.107 Section 291.107 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER...
30 CFR 291.115 - How do I exhaust administrative remedies?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I exhaust administrative remedies? 291.115 Section 291.115 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT...
30 CFR 291.115 - How do I exhaust administrative remedies?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false How do I exhaust administrative remedies? 291.115 Section 291.115 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER...
Activity-dependent dendritic spine neck changes are correlated with synaptic strength
Araya, Roberto; Vogels, Tim P.; Yuste, Rafael
2014-01-01
Most excitatory inputs in the mammalian brain are made on dendritic spines, rather than on dendritic shafts. Spines compartmentalize calcium, and this biochemical isolation can underlie input-specific synaptic plasticity, providing a raison d’etre for spines. However, recent results indicate that the spine can experience a membrane potential different from that in the parent dendrite, as though the spine neck electrically isolated the spine. Here we use two-photon calcium imaging of mouse neocortical pyramidal neurons to analyze the correlation between the morphologies of spines activated under minimal synaptic stimulation and the excitatory postsynaptic potentials they generate. We find that excitatory postsynaptic potential amplitudes are inversely correlated with spine neck lengths. Furthermore, a spike timing-dependent plasticity protocol, in which two-photon glutamate uncaging over a spine is paired with postsynaptic spikes, produces rapid shrinkage of the spine neck and concomitant increases in the amplitude of the evoked spine potentials. Using numerical simulations, we explore the parameter regimes for the spine neck resistance and synaptic conductance changes necessary to explain our observations. Our data, directly correlating synaptic and morphological plasticity, imply that long-necked spines have small or negligible somatic voltage contributions, but that, upon synaptic stimulation paired with postsynaptic activity, they can shorten their necks and increase synaptic efficacy, thus changing the input/output gain of pyramidal neurons. PMID:24982196
Ntilikina, Yves; Bahlau, David; Garnon, Julien; Schuller, Sébastien; Walter, Axel; Schaeffer, Mickaël; Steib, Jean-Paul; Charles, Yann Philippe
2017-08-01
OBJECTIVE Percutaneous instrumentation in thoracolumbar fractures is intended to decrease paravertebral muscle damage by avoiding dissection. The aim of this study was to compare muscles at instrumented levels in patients who were treated by open or percutaneous surgery. METHODS Twenty-seven patients underwent open instrumentation, and 65 were treated percutaneously. A standardized MRI protocol using axial T1-weighted sequences was performed at a minimum 1-year follow-up after implant removal. Two independent observers measured cross-sectional areas (CSAs, in cm 2 ) and region of interest (ROI) signal intensity (in pixels) of paravertebral muscles by using OsiriX at the fracture level, and at cranial and caudal instrumented pedicle levels. An interobserver comparison was made using the Bland-Altman method. Reference ROI muscle was assessed in the psoas and ROI fat subcutaneously. The ratio ROI-CSA/ROI-fat was compared for patients treated with open versus percutaneous procedures by using a linear mixed model. A linear regression analyzed additional factors: age, sex, body mass index (BMI), Pfirrmann grade of adjacent discs, and duration of instrumentation in situ. RESULTS The interobserver agreement was good for all CSAs. The average CSA for the entire spine was 15.7 cm 2 in the open surgery group and 18.5 cm 2 in the percutaneous group (p = 0.0234). The average ROI-fat and ROI-muscle signal intensities were comparable: 497.1 versus 483.9 pixels for ROI-fat and 120.4 versus 111.7 pixels for ROI-muscle in open versus percutaneous groups. The ROI-CSA varied between 154 and 226 for open, and between 154 and 195 for percutaneous procedures, depending on instrumented levels. A significant difference of the ROI-CSA/ROI-fat ratio (0.4 vs 0.3) was present at fracture levels T12-L1 (p = 0.0329) and at adjacent cranial (p = 0.0139) and caudal (p = 0.0100) instrumented levels. Differences were not significant at thoracic levels. When adjusting based on age, BMI, and Pfirrmann grade, a significant difference between open and percutaneous procedures regarding the ROI-CSA/ROI-fat ratio was present in the lumbar spine (p < 0.01). Sex and duration of instrumentation had no significant influence. CONCLUSIONS Percutaneous instrumentation decreased muscle atrophy compared with open surgery. The MRI signal differences for T-12 and L-1 fractures indicated less fat infiltration within CSAs in patients who received percutaneous treatment. Differences were not evidenced at thoracic levels, where CSAs were smaller. Fat infiltration was not significantly different at lumbar levels with either procedure in elderly patients with associated discopathy and higher BMI. In younger patients, there was less fat infiltration of lumbar paravertebral muscles with percutaneous procedures.
2011-01-01
Uncovering the mechanisms that regulate dendritic spine morphology has been limited, in part, by the lack of efficient and unbiased methods for analyzing spines. Here, we describe an automated 3D spine morphometry method and its application to spine remodeling in live neurons and spine abnormalities in a disease model. We anticipate that this approach will advance studies of synapse structure and function in brain development, plasticity, and disease. PMID:21982080
Penazzi, Lorène; Tackenberg, Christian; Ghori, Adnan; Golovyashkina, Nataliya; Niewidok, Benedikt; Selle, Karolin; Ballatore, Carlo; Smith, Amos B.; Bakota, Lidia; Brandt, Roland
2016-01-01
Dendritic spines represent the major postsynaptic input of excitatory synapses. Loss of spines and changes in their morphology correlate with cognitive impairment in Alzheimer’s disease (AD) and are thought to occur early during pathology. Therapeutic intervention at a preclinical stage of AD to modify spine changes might thus be warranted. To follow the development and to potentially interfere with spine changes over time, we established a long term ex vivo model from organotypic cultures of the hippocampus from APP transgenic and control mice. The cultures exhibit spine loss in principal hippocampal neurons, which closely resembles the changes occurring in vivo, and spine morphology progressively changes from mushroom-shaped to stubby. We demonstrate that spine changes are completely reversed within few days after blocking amyloid-β (Aβ) production with the gamma-secretase inhibitor DAPT. We show that the microtubule disrupting drug nocodazole leads to spine loss similar to Aβ expressing cultures and suppresses DAPT-mediated spine recovery in slices from APP transgenic mice. Finally, we report that epothilone D (EpoD) at a subnanomolar concentration, which slightly stabilizes microtubules in model neurons, completely reverses Aβ-induced spine loss and increases thin spine density. Taken together the data indicate that Aβ causes spine changes by microtubule destabilization and that spine recovery requires microtubule polymerization. Moreover, our results suggest that a low, subtoxic concentration of EpoD is sufficient to reduce spine loss during the preclinical stage of AD. PMID:26772969
Ultrastructure of spines and associated terminals on brainstem neurons controlling auditory input
Brown, M. Christian; Lee, Daniel J.; Benson, Thane E.
2013-01-01
Spines are unique cellular appendages that isolate synaptic input to neurons and play a role in synaptic plasticity. Using the electron microscope, we studied spines and their associated synaptic terminals on three groups of brainstem neurons: tensor tympani motoneurons, stapedius motoneurons, and medial olivocochlear neurons, all of which exert reflexive control of processes in the auditory periphery. These spines are generally simple in shape; they are infrequent and found on the somata as well as the dendrites. Spines do not differ in volume among the three groups of neurons. In all cases, the spines are associated with a synaptic terminal that engulfs the spine rather than abuts its head. The positions of the synapses are variable, and some are found at a distance from the spine, suggesting that the isolation of synaptic input is of diminished importance for these spines. Each group of neurons receives three common types of synaptic terminals. The type of terminal associated with spines of the motoneurons contains pleomorphic vesicles, whereas the type associated with spines of olivocochlear neurons contains large round vesicles. Thus, spine-associated terminals in the motoneurons appear to be associated with inhibitory processes but in olivocochlear neurons they are associated with excitatory processes. PMID:23602963
Late effects of 1H irradiation on hippocampal physiology
NASA Astrophysics Data System (ADS)
Kiffer, Frederico; Howe, Alexis K.; Carr, Hannah; Wang, Jing; Alexander, Tyler; Anderson, Julie E.; Groves, Thomas; Seawright, John W.; Sridharan, Vijayalakshmi; Carter, Gwendolyn; Boerma, Marjan; Allen, Antiño R.
2018-05-01
NASA's Missions to Mars and beyond will expose flight crews to potentially dangerous levels of charged-particle radiation. Of all charged nuclei, 1H is the most abundant charged particle in both the galactic cosmic ray (GCR) and solar particle event (SPE) spectra. There are currently no functional spacecraft shielding materials that are able to mitigate the charged-particle radiation encountered in space. Recent studies have demonstrated cognitive injuries due to high-dose 1H exposures in rodents. Our study investigated the effects of 1H irradiation on neuronal morphology in the hippocampus of adult male mice. 6-month-old mice received whole-body exposure to 1H at 0.5 and 1 Gy (150 MeV/n; 0.35-0.55 Gy/min) at NASA's Space Radiation Laboratory in Upton, NY. At 9-months post-irradiation, we tested each animal's open-field exploratory performance. After sacrifice, we dissected the brains along the midsagittal plane, and then either fixed or dissected further and snap-froze them. Our data showed that exposure to 0.5 Gy or 1 Gy 1H significantly increased animals' anxiety behavior in open-field testing. Our micromorphometric analyses revealed significant decreases in mushroom spine density and dendrite morphology in the Dentate Gyrus, Cornu Ammonis 3 and 1 of the hippocampus, and lowered expression of synaptic markers. Our data suggest 1H radiation significantly increased exploration anxiety and modulated the dendritic spine and dendrite morphology of hippocampal neurons at a dose of 0.5 or 1 Gy.
Analyses of Simulated Reconnection-Driven Solar Polar Jets
NASA Astrophysics Data System (ADS)
Roberts, M. A.; Uritsky, V. M.; Karpen, J. T.; DeVore, C. R.
2014-12-01
Solar polar jets are observed to originate in regions within the open field of solar coronal holes. These so called "anemone" regions are generally accepted to be regions of opposite polarity, and are associated with an embedded dipole topology, consisting of a fan-separatrix and a spine line emanating from a null point occurring at the top of the dome shaped fan surface. Previous analysis of these jets (Pariat et al. 2009,2010) modeled using the Adaptively Refined Magnetohydrodynamics Solver (ARMS) has supported the claim that magnetic reconnection across current sheets formed at the null point between the highly twisted closed field of the dipole and open field lines surrounding it releases the energy necessary to drive these jets. However, these initial simulations assumed a "static" environment for the jets, neglecting effects due to gravity, solar wind and the expanding spherical geometry. A new set of ARMS simulations taking into account these additional physical processes was recently performed. Initial results are qualitatively consistent with the earlier Cartesian studies, demonstrating the robustness of the underlying ideal and resistive mechanisms. We focus on density and velocity fluctuations within a narrow radial slit aligned with the direction of the spine of the jet, as well as other physical properties, in order to identify and refine their signatures in the lower heliosphere. These refined signatures can be used as parameters by which plasma processes initiated by these jets may be identified in situ by future missions such as Solar Orbiter and Solar Probe Plus.
Statistical analysis of dendritic spine distributions in rat hippocampal cultures
2013-01-01
Background Dendritic spines serve as key computational structures in brain plasticity. Much remains to be learned about their spatial and temporal distribution among neurons. Our aim in this study was to perform exploratory analyses based on the population distributions of dendritic spines with regard to their morphological characteristics and period of growth in dissociated hippocampal neurons. We fit a log-linear model to the contingency table of spine features such as spine type and distance from the soma to first determine which features were important in modeling the spines, as well as the relationships between such features. A multinomial logistic regression was then used to predict the spine types using the features suggested by the log-linear model, along with neighboring spine information. Finally, an important variant of Ripley’s K-function applicable to linear networks was used to study the spatial distribution of spines along dendrites. Results Our study indicated that in the culture system, (i) dendritic spine densities were "completely spatially random", (ii) spine type and distance from the soma were independent quantities, and most importantly, (iii) spines had a tendency to cluster with other spines of the same type. Conclusions Although these results may vary with other systems, our primary contribution is the set of statistical tools for morphological modeling of spines which can be used to assess neuronal cultures following gene manipulation such as RNAi, and to study induced pluripotent stem cells differentiated to neurons. PMID:24088199
A dual role for the RhoGEF Ephexin5 in regulation of dendritic spine outgrowth
Hamilton, AM; Lambert, JT; Parajuli, LK; Vivas, O; Park, DK; Stein, IS; Jahncke, JN; Greenberg, ME; Margolis, SS; Zito, K
2017-01-01
The outgrowth of new dendritic spines is closely linked to the formation of new synapses, and is thought to be a vital component of the experience-dependent circuit plasticity that supports learning. Here, we examined the role of the RhoGEF Ephexin5 in driving activity-dependent spine outgrowth. We found that reducing Ephexin5 levels increased spine outgrowth, and increasing Ephexin5 levels decreased spine outgrowth in a GEF-dependent manner, suggesting that Ephexin5 acts as an inhibitor of spine outgrowth. Notably, we found that increased neural activity led to a proteasome-dependent reduction in the levels of Ephexin5 in neuronal dendrites, which could facilitate the enhanced spine outgrowth observed following increased neural activity. Surprisingly, we also found that Ephexin5-GFP levels were elevated on the dendrite at sites of future new spines, prior to new spine outgrowth. Moreover, lowering neuronal Ephexin5 levels inhibited new spine outgrowth in response to both global increases in neural activity and local glutamatergic stimulation of the dendrite, suggesting that Ephexin5 is necessary for activity-dependent spine outgrowth. Our data support a model in which Ephexin5 serves a dual role in spinogenesis, acting both as a brake on overall spine outgrowth and as a necessary component in the site-specific formation of new spines. PMID:28185854
A dual role for the RhoGEF Ephexin5 in regulation of dendritic spine outgrowth.
Hamilton, A M; Lambert, J T; Parajuli, L K; Vivas, O; Park, D K; Stein, I S; Jahncke, J N; Greenberg, M E; Margolis, S S; Zito, K
2017-04-01
The outgrowth of new dendritic spines is closely linked to the formation of new synapses, and is thought to be a vital component of the experience-dependent circuit plasticity that supports learning. Here, we examined the role of the RhoGEF Ephexin5 in driving activity-dependent spine outgrowth. We found that reducing Ephexin5 levels increased spine outgrowth, and increasing Ephexin5 levels decreased spine outgrowth in a GEF-dependent manner, suggesting that Ephexin5 acts as an inhibitor of spine outgrowth. Notably, we found that increased neural activity led to a proteasome-dependent reduction in the levels of Ephexin5 in neuronal dendrites, which could facilitate the enhanced spine outgrowth observed following increased neural activity. Surprisingly, we also found that Ephexin5-GFP levels were elevated on the dendrite at sites of future new spines, prior to new spine outgrowth. Moreover, lowering neuronal Ephexin5 levels inhibited new spine outgrowth in response to both global increases in neural activity and local glutamatergic stimulation of the dendrite, suggesting that Ephexin5 is necessary for activity-dependent spine outgrowth. Our data support a model in which Ephexin5 serves a dual role in spinogenesis, acting both as a brake on overall spine outgrowth and as a necessary component in the site-specific formation of new spines. Copyright © 2017 Elsevier Inc. All rights reserved.
Intravital imaging of dendritic spine plasticity
Sau Wan Lai, Cora
2014-01-01
Abstract Dendritic spines are the postsynaptic part of most excitatory synapses in the mammalian brain. Recent works have suggested that the structural and functional plasticity of dendritic spines have been associated with information coding and memories. Advances in imaging and labeling techniques enable the study of dendritic spine dynamics in vivo. This perspective focuses on intravital imaging studies of dendritic spine plasticity in the neocortex. I will introduce imaging tools for studying spine dynamics and will further review current findings on spine structure and function under various physiological and pathological conditions. PMID:28243511
Orefice, Lauren L.; Waterhouse, Emily G.; Partridge, John G.; Lalchandani, Rupa R.; Vicini, Stefano
2013-01-01
Dendritic spines undergo the processes of formation, maturation, and pruning during development. Molecular mechanisms controlling spine maturation and pruning remain largely unknown. The gene for brain-derived neurotrophic factor (BDNF) produces two pools of mRNA, with either a short or long 3′ untranslated region (3′ UTR). Our previous results show that short 3′ UTR Bdnf mRNA is restricted to cell bodies, whereas long 3′ UTR Bdnf mRNA is also trafficked to dendrites for local translation. Mutant mice lacking long 3′ UTR Bdnf mRNA display normal spines at 3 weeks of age, but thinner and denser spines in adults compared to wild-type littermates. These observations suggest that BDNF translated from long 3′ UTR Bdnf mRNA, likely in dendrites, is required for spine maturation and pruning. In this study, using rat hippocampal neuronal cultures, we found that knocking down long 3′ UTR Bdnf mRNA blocked spine head enlargement and spine elimination, whereas overexpressing long 3′ UTR Bdnf mRNA had the opposite effect. The effect of long 3′ UTR Bdnf mRNA on spine head enlargement and spine elimination was diminished by a human single-nucleotide polymorphism (SNP, rs712442) in its 3′ UTR that inhibited dendritic localization of Bdnf mRNA. Furthermore, we found that overexpression of either Bdnf mRNA increased spine density at earlier time points. Spine morphological alterations were associated with corresponding changes in density, size, and function of synapses. These results indicate that somatically synthesized BDNF promotes spine formation, whereas dendritically synthesized BDNF is a key regulator of spine head growth and spine pruning. PMID:23843530
Spine micromorphology of normal and hyperhydric Mammillaria gracilis Pfeiff. (Cactaceae) shoots.
Peharec, P; Posilović, H; Balen, B; Krsnik-Rasol, M
2010-07-01
Artificial conditions of tissue culture affect growth and physiology of crassulacean acid metabolism plants which often results in formation of hyperhydric shoots. In in vitro conditions Mammillaria gracilis Pfeiff. (Cactaceae) growth switches from organized to unorganized way, producing a habituated organogenic callus which simultaneously regenerates morphologically normal as well as altered hyperhydric shoots. In this study, influence of tissue culture conditions on morphology of cactus spines of normal and hyperhydric shoots was investigated. Spines of pot-grown Mammillaria plants and of in vitro regenerated shoots were examined with stereo microscope and scanning electron microscope. The pot-grown plants had 16-17 spines per areole. In vitro grown normal shoots, even though they kept typical shoot morphology, had lower number of spines (11-12) and altered spine morphology. This difference was even more pronounced in spine number (six to seven) and morphology of the hyperhydric shoots. Scanning electron microscopy analysis revealed remarkable differences in micromorphology of spine surface between pot-grown and in vitro grown shoots. Spines of in vitro grown normal shoots showed numerous long trichomes, which were more elongated on spines of the hyperhydric shoots; the corresponding structures on spine surface of pot-grown plants were noticed only as small protrusions. Scanning electron microscopy morphometric studies showed that the spines of pot-grown plants were significantly longer compared to the spines of shoots grown in tissue culture. Moreover, transverse section shape varies from elliptical in pot-grown plants to circular in normal and hyperhydric shoots grown in vitro. Cluster and correspondence analyses performed on the scanning electron microscope obtained results suggest great variability among spines of pot-grown plants. Spines of in vitro grown normal and hyperhydric shoots showed low level of morphological variation among themselves despite the significant difference in shoot morphology.
Gebauer, Roman; Řepka, Radomír; Šmudla, Radek; Mamoňová, Miroslava; Ďurkovič, Jaroslav
2016-01-01
Although spine variation within cacti species or populations is assumed to be large, the minimum sample size of different spine anatomical and morphological traits required for species description is less studied. There are studies where only 2 spines were used for taxonomical comparison amnog species. Therefore, the spine structure variation within areoles and individuals of one population of Gymnocalycium kieslingii subsp. castaneum (Ferrari) Slaba was analyzed. Fifteen plants were selected and from each plant one areole from the basal, middle and upper part of the plant body was sampled. A scanning electron microscopy was used for spine surface description and a light microscopy for measurements of spine width, thickness, cross-section area, fiber diameter and fiber cell wall thickness. The spine surface was more visible and damaged less in the upper part of the plant body than in the basal part. Large spine and fiber differences were found between upper and lower parts of the plant body, but also within single areoles. In general, the examined traits in the upper part had by 8-17% higher values than in the lower parts. The variation of spine and fiber traits within areoles was lower than the differences between individuals. The minimum sample size was largely influenced by the studied spine and fiber traits, ranging from 1 to 70 spines. The results provide pioneer information useful in spine sample collection in the field for taxonomical, biomechanical and structural studies. Nevertheless, similar studies should be carried out for other cacti species to make generalizations. The large spine and fiber variation within areoles observed in our study indicates a very complex spine morphogenesis.
Gebauer, Roman; Řepka, Radomír; Šmudla, Radek; Mamoňová, Miroslava; Ďurkovič, Jaroslav
2016-01-01
Abstract Although spine variation within cacti species or populations is assumed to be large, the minimum sample size of different spine anatomical and morphological traits required for species description is less studied. There are studies where only 2 spines were used for taxonomical comparison amnog species. Therefore, the spine structure variation within areoles and individuals of one population of Gymnocalycium kieslingii subsp. castaneum (Ferrari) Slaba was analyzed. Fifteen plants were selected and from each plant one areole from the basal, middle and upper part of the plant body was sampled. A scanning electron microscopy was used for spine surface description and a light microscopy for measurements of spine width, thickness, cross-section area, fiber diameter and fiber cell wall thickness. The spine surface was more visible and damaged less in the upper part of the plant body than in the basal part. Large spine and fiber differences were found between upper and lower parts of the plant body, but also within single areoles. In general, the examined traits in the upper part had by 8–17% higher values than in the lower parts. The variation of spine and fiber traits within areoles was lower than the differences between individuals. The minimum sample size was largely influenced by the studied spine and fiber traits, ranging from 1 to 70 spines. The results provide pioneer information useful in spine sample collection in the field for taxonomical, biomechanical and structural studies. Nevertheless, similar studies should be carried out for other cacti species to make generalizations. The large spine and fiber variation within areoles observed in our study indicates a very complex spine morphogenesis. PMID:27698579
Garcia, Jodan D; Arnold, Stephen; Tetley, Kylie; Voight, Kiel; Frank, Rachael Anne
2016-01-01
Cervical mobilization and manipulation are frequently used to treat patients diagnosed with cervicogenic headache (CEH); however, there is conflicting evidence on the efficacy of these manual therapy techniques. The purpose of this review is to investigate the effects of cervical mobilization and manipulation on pain intensity and headache frequency, compared to traditional physical therapy interventions in patients diagnosed with CEH. A total of 66 relevant studies were originally identified through a review of the literature, and the 25 most suitable articles were fully evaluated via a careful review of the text. Ultimately, 10 studies met the inclusion criteria: (1) randomized controlled trial (RCT) or open RCT; the study contained at least two separate groups of subjects that were randomly assigned either to a cervical spine mobilization or manipulation or a group that served as a comparison; (2) subjects must have had a diagnosis of CEH; (3) the treatment group received either spinal mobilization or spinal manipulation, while the control group received another physical therapy intervention or placebo control; and (4) the study included headache pain and frequency as outcome measurements. Seven of the 10 studies had statistically significant findings that subjects who received mobilization or manipulation interventions experienced improved outcomes or reported fewer symptoms than control subjects. These results suggest that mobilization or manipulation of the cervical spine may be beneficial for individuals who suffer from CEH, although heterogeneity of the studies makes it difficult to generalize the findings.
Minifilament Eruption as the Source of a Blowout Jet, C-class Flare, and Type-III Radio Burst
NASA Astrophysics Data System (ADS)
Hong, Junchao; Jiang, Yunchun; Yang, Jiayan; Li, Haidong; Xu, Zhe
2017-01-01
We report a strong minifilament eruption associated with Geostationary Operational Environmental Satellite C1.6 flare and WIND type-III radio burst. The minifilament, which lies at the periphery of active region 12259, is detected by Hα images from the New Vacuum Solar Telescope. The minifilament undergoes a partial and then a full eruption. Simultaneously, two co-spatial jets are successively observed in extreme ultraviolet images from the Solar Dynamic Observatory. The first jet exhibits a typical fan-spine geometry, suggesting that the co-spatial minifilament is possibly embedded in magnetic fields with a fan-spine structure. However, the second jet displays blowout morphology when the entire minifilament erupts upward, leaving behind a hard X-ray emission source in the base. Differential emission measure analyses show that the eruptive region is heated up to about 4 MK during the fan-spine jet, while up to about 7 MK during the blowout jet. In particular, the blowout jet is accompanied by an interplanetary type-III radio burst observed by WIND/WAVES in the frequency range from above 10 to 0.1 MHz. Hence, the minifilament eruption is correlated with the interplanetary type-III radio burst for the first time. These results not only suggest that coronal jets can result from magnetic reconnection initiated by erupting minifilaments with open fields, but also shed light on the potential influence of minifilament eruption on interplanetary space.
MINIFILAMENT ERUPTION AS THE SOURCE OF A BLOWOUT JET, C-CLASS FLARE, AND TYPE-III RADIO BURST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Junchao; Jiang, Yunchun; Yang, Jiayan
We report a strong minifilament eruption associated with Geostationary Operational Environmental Satellite C1.6 flare and WIND type-III radio burst. The minifilament, which lies at the periphery of active region 12259, is detected by H α images from the New Vacuum Solar Telescope. The minifilament undergoes a partial and then a full eruption. Simultaneously, two co-spatial jets are successively observed in extreme ultraviolet images from the Solar Dynamic Observatory . The first jet exhibits a typical fan-spine geometry, suggesting that the co-spatial minifilament is possibly embedded in magnetic fields with a fan-spine structure. However, the second jet displays blowout morphology whenmore » the entire minifilament erupts upward, leaving behind a hard X-ray emission source in the base. Differential emission measure analyses show that the eruptive region is heated up to about 4 MK during the fan-spine jet, while up to about 7 MK during the blowout jet. In particular, the blowout jet is accompanied by an interplanetary type-III radio burst observed by WIND /WAVES in the frequency range from above 10 to 0.1 MHz. Hence, the minifilament eruption is correlated with the interplanetary type-III radio burst for the first time. These results not only suggest that coronal jets can result from magnetic reconnection initiated by erupting minifilaments with open fields, but also shed light on the potential influence of minifilament eruption on interplanetary space.« less
Global Body Posture Evaluation in Patients with Temporomandibular Joint Disorder
Saito, Eliza Tiemi; Akashi, Paula Marie Hanai; de Camargo Neves Sacco, Isabel
2009-01-01
AIM: To identify the relationship between anterior disc displacement and global posture (plantar arches, lower limbs, shoulder and pelvic girdle, vertebral spine, head and mandibles). Common signs and symptoms of anterior disc displacement were also identified. INTRODUCTION: Global posture deviations cause body adaptation and realignment, which may interfere with the organization and function of the temporomandibular joint. METHODS : Global posture evaluation was performed in a group of 10 female patients (20 to 30 years of age) with temporomandibular joint disc displacement and in a control group of 16 healthy female volunteers matched for age, weight and height. Anterior disc displacement signs, symptoms and the presence of parafunctional habits were also identified through interview. RESULTS: Patients with disc displacement showed a higher incidence of pain in the temporomandibular joint area, but there were no differences in parafunctional habits between the groups. In the disc displacement group, postural deviations were found in the pelvis (posterior rotation), lumbar spine (hyperlordosis), thoracic spine (rectification), head (deviation to the right) and mandibles (deviation to the left with open mouth). There were no differences in the longitudinal plantar arches between the groups. CONCLUSION: Our results suggest a close relationship between body posture and temporomandibular disorder, though it is not possible to determine whether postural deviations are the cause or the result of the disorder. Hence, postural evaluation could be an important component in the overall approach to providing accurate prevention and treatment in the management of patients with temporomandibular disorder. PMID:19142549
Protective effect of lycopene on high-fat diet-induced cognitive impairment in rats.
Wang, Zhiqiang; Fan, Jin; Wang, Jian; Li, Yuxia; Xiao, Li; Duan, Dan; Wang, Qingsong
2016-08-03
A Western diet, high in saturated fats, has been linked to the development of cognitive impairment. Lycopene has recently received considerable attention for its potent protective properties demonstrated in several models of nervous system dysfunction. However, it remains unclear whether lycopene exerts protective effects on cognition. The present study aimed to investigate the protective effects of lycopene on learning and memory impairment and the potential underlying mechanism in rats fed a high-fat diet (HFD). One-month-old male rats were fed different diets for 16 weeks (n=12 per group), including a standard chow diet (CD), a HFD, or a HFD plus lycopene (4mg/kg, oral gavage in the last three weeks). Behavioral testing, including the Morris water maze (MWM), object recognition task (ORT), and anxiety-like behavior in an open field (OF), were assessed at week 16. The dendritic spine density and neuronal density in the hippocampal CA1 subfield were subsequently measured. The results indicate that HFD consumption for 16 weeks significantly impaired spatial memory (P<0.001), working memory (P<0.01), and object recognition memory (P<0.01), decreased the dendritic spine density (P<0.001), damaged pyramidal neurons in the CA1 subfield (P<0.001) compared with the CD group. However, lycopene significantly attenuated learning and memory impairments and prevented the reduction in dendritic spine density (P<0.001). Thus, this study indicated that lycopene helps to protect HFD induced cognitive dysfunction. Copyright © 2016. Published by Elsevier Ireland Ltd.
Arndt, Andreas; Nüsser, Peter; Graichen, Kurt; Müller, Johannes; Lampe, Bernhard
2008-10-01
A control strategy for rotary blood pumps meeting different user-selectable control objectives is proposed: maximum support with the highest feasible flow rate versus medium support with maximum ventricular washout and controlled opening of the aortic valve (AoV). A pulsatility index (PI) is calculated from the pressure difference, which is deduced from the axial thrust measured by the magnetic bearing of the pump. The gradient of PI with respect to pump speed (GPI) is estimated via online system identification. The outer loop of a cascaded controller regulates GPI to a reference value satisfying the selected control objective. The inner loop controls the PI to a reference value set by the outer loop. Adverse pumping states such as suction and regurgitation can be detected on the basis of the GPI estimates and corrected by the controller. A lumped-parameter computer model of the assisted circulation was used to simulate variations of ventricular contractility, pulmonary venous pressure, and aortic pressure. The performance of the outer control loop was demonstrated by transitions between the two control modes. Fast reaction of the inner loop was tested by stepwise reduction of venous return. For maximum support, a low PI was maintained without inducing ventricular collapse. For maximum washout, the pump worked at a high PI in the transition region between the opening and the permanently closed AoV. The cascaded control of GPI and PI is able to meet different control objectives and is worth testing in vitro and in vivo.
A Retrospective Study of Cervical Spine MRI Findings in Children with Abusive Head Trauma.
Governale, Lance S; Brink, Farah W; Pluto, Charles P; Schunemann, Victoria A; Weber, Rachel; Rusin, Jerome; Fischer, Beth A; Letson, Megan M
2018-01-01
Increasing attention has been given to the possible association of cervical spine (c-spine) injuries with abusive head trauma (AHT). The aims of this study were to describe c-spine MRI findings in hospitalized AHT patients. This is a retrospective study of children under the age of 5 years with AHT admitted to hospital in 2004-2013. Those with c-spine MRI were identified, and the images were reviewed. 250 AHT cases were identified, with 34 (14%) undergoing c-spine MRI. Eleven patients (32%) had 25 findings, including hematoma in 2, occiput-C1-C2 edema in 3, prevertebral edema in 6, facet edema in 2, and interspinous and/or muscular edema in 10. No patients had a clinically evident c-spine injury, a clinically unstable c-spine, or required c-spine surgery. C-spine MRI may identify abnormalities not apparent upon physical examination and the procedure should therefore be considered in cases of suspected AHT. © 2017 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazzarella, Ricardo; Slocum, Alexander H.; Doherty, Tristan
Electrochemical cells and methods of making electrochemical cells are described herein. In some embodiments, an apparatus includes a multi-layer sheet for encasing an electrode material for an electrochemical cell. The multi-layer sheet including an outer layer, an intermediate layer that includes a conductive substrate, and an inner layer disposed on a portion of the conductive substrate. The intermediate layer is disposed between the outer layer and the inner layer. The inner layer defines an opening through which a conductive region of the intermediate layer is exposed such that the electrode material can be electrically connected to the conductive region. Thus,more » the intermediate layer can serve as a current collector for the electrochemical cell.« less
Hubbell, Joel M.; Sisson, James B.
2001-01-01
A deep tensiometer is configured with an outer guide tube having a vented interval along a perforate section at its lower end, which is isolated from atmospheric pressure at or above grade. A transducer having a monitoring port and a reference port is located within a coaxial inner guide tube. The reference port of the transducer is open to the vented interval of the outer guide tube, which has the same gas pressure as in the sediment surrounding the tensiometer. The reference side of the pressure transducer is thus isolated from the effects of atmospheric pressure changes and relative to pressure changes in the material surrounding the tensiometer measurement location and so it is automatically compensated for such pressure changes.
NASA Technical Reports Server (NTRS)
Hagler, R., Jr.
1974-01-01
A method of evaluating the normally open normally closed, explosive actuated valves that were selected for use in the trajectory correction propulsion subsystem of the Thermoelectric Outer Planet Spacecraft (TOPS) program is presented. The design philosophy which determined the requirements for highly reliable valves that could provide the performance capability during long duration (10 year) missions to the outer planets is discussed. The techniques that were used to fabricate the valves and manifold ten valves into an assembly with the capability of five propellant-flow initiation/isolation sequences are described. The test program, which was conducted to verify valve design requirements, is outlined and the more significant results are shown.
Electrochemical cells and methods of manufacturing the same
Bazzarella, Ricardo; Slocum, Alexander H; Doherty, Tristan; Cross, III, James C
2015-11-03
Electrochemical cells and methods of making electrochemical cells are described herein. In some embodiments, an apparatus includes a multi-layer sheet for encasing an electrode material for an electrochemical cell. The multi-layer sheet including an outer layer, an intermediate layer that includes a conductive substrate, and an inner layer disposed on a portion of the conductive substrate. The intermediate layer is disposed between the outer layer and the inner layer. The inner layer defines an opening through which a conductive region of the intermediate layer is exposed such that the electrode material can be electrically connected to the conductive region. Thus, the intermediate layer can serve as a current collector for the electrochemical cell.
Kennedy, Emily B; Hsiung, Bor-Kai; Swift, Nathan B; Tan, Kwek-Tze
2017-11-01
Hedgehogs are agile climbers, scaling trees and plants to heights exceeding 10m while foraging insects. Hedgehog spines (a.k.a. quills) provide fall protection by absorbing shock and could offer insights for the design of lightweight, material-efficient, impact-resistant structures. There has been some study of flexural properties of hedgehog spines, but an understanding of how this keratinous biological material is affected by various temperature and relative humidity treatments, or how spine color (multicolored vs. white) affects mechanics, is lacking. To bridge this gap in the literature, we use three-point bending to analyze the effect of temperature, humidity, spine color, and their interactions on flexural strength and modulus of hedgehog spines. We also compare specific strength and stiffness of hedgehog spines to conventional engineered materials. We find hedgehog spine flexural properties can be finely tuned by modifying environmental conditioning parameters. White spines tend to be stronger and stiffer than multicolored spines. Finally, for most temperature and humidity conditioning parameters, hedgehog spines are ounce for ounce stronger than 201 stainless steel rods of the same diameter but as pliable as styrene rods with a slightly larger diameter. This unique combination of strength and elasticity makes hedgehog spines exemplary shock absorbers, and a suitable reference model for biomimicry. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kim, Jun Young; Kwon, Jae Yeol; Kim, Moon Seok; Lee, Jeong Jae; Kim, Il Sup; Hong, Jae Taek
2018-03-01
To compare the morphometry of subaxial cervical spine between cerebral palsy (CP) and normal control. We retrospectively analyzed 72 patients with CP, as well as 72 patients from normal population. The two groups were matched for age, sex, and body mass index. Pedicle, lateral mass (LM), and vertebral foramen were evaluated using computed tomography (CT) imaging. Pedicle diameter, LM height, thickness, width and vertebral foramen asymmetry (VFA) were measured and compared between the two groups. Cervical dynamic motion, disc and facet joint degeneration were investigated. Additionally, we compared the morphology of LM between convex side and concave side with cervical scoliotic CP patients. LM height was smaller in CP group. LM thickness and width were larger in CP group at mid-cervical level. In 40 CP patients with cervical scoliosis, there were no height and width differences between convex and concave side. Pedicle outer diameter was not statistically different between two groups. Pedicle inner diameter was significantly smaller in CP group. Pedicle sclerosis was more frequent in CP patients. VFA was larger in CP group at C3, C4, and C5. Disc/facet degeneration grade was higher in the CP group. Cervical motion of CP group was smaller than those of the control group. LM morphology of CP patients was different from normal population. Sclerotic pedicles and vertebral foramen asymmetry were more commonly identified in CP patients. CP patients were more likely to demonstrate progressive disc/facet degeneration. This data may provide useful information on cervical posterior instrumentation in CP patients.
Why do some intervertebral discs degenerate, when others (in the same spine) do not?
Adams, Michael A; Lama, Polly; Zehra, Uruj; Dolan, Patricia
2015-03-01
This review suggests why some discs degenerate rather than age normally. Intervertebral discs are avascular pads of fibrocartilage that allow movement between vertebral bodies. Human discs have a low cell density and a limited ability to adapt to mechanical demands. With increasing age, the matrix becomes yellowed, fibrous, and brittle, but if disc structure remains intact, there is little impairment in function, and minimal ingrowth of blood vessels or nerves. Approximately half of old lumbar discs degenerate in the sense of becoming physically disrupted. The posterior annulus and lower lumbar discs are most affected, presumably because they are most heavily loaded. Age and genetic inheritance can weaken discs to such an extent that they are physically disrupted during everyday activities. Damage to the endplate or annulus typically decompresses the nucleus, concentrates stress within the annulus, and allows ingrowth of nerves and blood vessels. Matrix disruption progresses by mechanical and biological means. The site of initial damage leads to two disc degeneration "phenotypes": endplate-driven degeneration is common in the upper lumbar and thoracic spine, and annulus-driven degeneration is common at L4-S1. Discogenic back pain can be initiated by tissue disruption, and amplified by inflammation and infection. Healing is possible in the outer annulus only, where cell density is highest. We conclude that some discs degenerate because they are disrupted by excessive mechanical loading. This can occur without trauma if tissues are weakened by age and genetic inheritance. Moderate mechanical loading, in contrast, strengthens all spinal tissues, including discs. © 2014 Wiley Periodicals, Inc.
Habitat-dependent olfactory discrimination in three-spined sticklebacks (Gasterosteus aculeatus).
Hiermes, Meike; Mehlis, Marion; Rick, Ingolf P; Bakker, Theo C M
2015-07-01
The ability to recognize conspecifics is indispensible for differential treatment of particular individuals in social contexts like grouping behavior. The advantages of grouping are multifarious, and there exist numerous additional benefits of joining aggregations of conspecifics. Recognition is based on different signals and transmitted via multiple channels, among others the olfactory channel. The sensory system or the combination of sensory modalities used in recognition processes is highly dependent on the availability and effectiveness of modalities, which are a function of the environmental conditions. Using F1-generations of six three-spined stickleback (Gasterosteus aculeatus) populations from two habitat types (tea-stained and clear-water lakes) from the Outer Hebrides, Scotland, we investigated whether individuals are able to recognize members of their own population solely based on olfactory cues and whether the habitat type an individual originated from had an influence on its recognition abilities. When given the choice (own vs. foreign population) sticklebacks from tea-stained lakes significantly preferred the odor of their own population, whereas fish from clear-water habitats did not show any preference. Moreover, fish from the two habitat types differed significantly in their recognition abilities, indicating that olfactory communication is better developed when visual signaling is disturbed. Thus, the observed odor preferences appear to be the consequence of different selective constraints and adaptations as a result of the differences in environmental conditions that have acted on the parental generations. These adaptations are likely genetically based as the differences are present in the F1-generation that had been reared under identical laboratory conditions.
Apparatus tube configuration and mounting for solid oxide fuel cells
Zymboly, G.E.
1993-09-14
A generator apparatus is made containing long, hollow, tubular, fuel cells containing an inner air electrode, an outer fuel electrode, and solid electrolyte there between, placed between a fuel distribution board and a board which separates the combustion chamber from the generating chamber, where each fuel cell has an insertable open end and in insertable, plugged, closed end, the plugged end being inserted into the fuel distribution board and the open end being inserted through the separator board where the plug is completely within the fuel distribution board. 3 figures.
Loik, Michael E
2008-09-01
Cactus spines reduce herbivory, direct water toward roots and reduce the impacts of high- and low-temperature extremes. Yet, shading of stems by spines reduces incident photosynthetic photon flux density (PFD), photosynthesis and growth. This study compared spinescence, PFD interception, stem temperature, Photosystem II (PSII) photochemistry and xanthophyll pigment composition for three species of cacti from the Mojave Desert, CA. The species vary in spinescence: Opuntia basilaris, which has no central or radial spines; Opuntia erinacea, which is densely covered with spines; and Opuntia phaeacantha, which has an intermediate coverage of spines. The role of spines was tested by removing spines from stems of O. erinacea. PFD interception was similar for both O. basilaris and O. phaeacantha, and about three times that for densely spined O. erinacea; removal of spines increased incident PFD three-fold. There were no effects of spines on stem temperatures. Steady-state light-response curves of chlorophyll a fluorescence from PSII indicated that PhiPSII, photochemical quenching (qP) and electron flux within PSII were lower, and non-photochemical quenching was higher, for O. erinacea in comparison to the other two species with less spines. After 2 months, qP was higher and electron flux lower, and xanthophyll pigment pool size was higher, for stems from which spines had been removed compared with intact stems. These three species allocate different amounts of biomass to spines, resulting in species-specific PFD interception, PSII photochemistry and xanthophyll pigment pool size, which may help maintain rates of photosynthesis during the hot, dry Mojave Desert summer.
High precision high flow range control valve
McCray, J.A.
1999-07-13
A fluid control valve is described having a valve housing having first and second valve housing openings for the ingress and egress of fluid through the control valve. Disposed within a void formed by the control valve is a sleeve having at least one sleeve opening to permit the flow of fluid therethrough. A flow restricter travels within the sleeve to progressively block off the sleeve opening and thereby control flow. A fluid passageway is formed between the first valve housing opening and the outer surface of the sleeve. A second fluid passageway is formed between the inside of the sleeve and the second valve housing opening. Neither fluid passageway contains more than one 90 [degree] turn. In the preferred embodiment only one of the two fluid passageways contains a 90[degree] turn. In another embodiment, the control valve housing is bifurcated by a control surface having control surface opening disposed therethrough. A flow restricter is in slidable contact with the control surface to restrict flow of fluid through the control surface openings. 12 figs.
High precision high flow range control valve
McCray, John A.
1999-01-01
A fluid control valve is described having a valve housing having first and second valve housing openings for the ingress and egress of fluid through the control valve. Disposed within a void formed by the control valve is a sleeve having at least one sleeve opening to permit the flow of fluid therethrough. A flow restricter travels within the sleeve to progressively block off the sleeve opening and thereby control flow. A fluid passageway is formed between the first valve housing opening and the outer surface of the sleeve. A second fluid passageway is formed between the inside of the sleeve and the second valve housing opening. Neither fluid passageway contains more than one 90.degree. turn. In the preferred embodiment only one of the two fluid passageways contains a 90.degree. turn. In another embodiment, the control valve housing is bifurcated by a control surface having control surface opening disposed therethrough. A flow restricter is in slidable contact with the control surface to restrict flow of fluid through the control surface openings.
Hot gas filter and system assembly
Lippert, Thomas Edwin; Palmer, Kathryn Miles; Bruck, Gerald Joseph; Alvin, Mary Anne; Smeltzer, Eugene E.; Bachovchin, Dennis Michael
1999-01-01
A filter element for separating fine dirty particles from a hot gas. The filter element comprises a first porous wall and a second porous wall. Each porous wall has an outer surface and an inner surface. The first and second porous walls being coupled together thereby forming a substantially closed figure and open at one end. The open end is formed to be coupled to a hot gas clean up system support structure. The first and second porous walls define a channel beginning at the open end and terminate at the closed end through which a filtered clean gas can flow through and out into the clean gas side of a hot gas clean up system.
Side wall cooling for nozzle segments for a gas turbine
Burdgick, Steven Sebastian
2002-01-01
A nozzle vane segment includes outer and inner band portions with a vane extending therebetween and defining first and second cavities separated by an impingement plate for flowing cooling medium for impingement cooling of nozzle side walls. The side wall of each nozzle segment has an undercut region. The impingement plate has an inturned flange with a plurality of openings. Cooling inserts or receptacles having an open end are received in the openings and the base and side walls of the receptacles have apertures for receiving cooling medium from the first cavity and directing the cooling medium for impingement cooling of the side wall of the nozzle segment and a portion of the nozzle wall.
Hot gas filter and system assembly
Lippert, T.E.; Palmer, K.M.; Bruck, G.J.; Alvin, M.A.; Smeltzer, E.E.; Bachovchin, D.M.
1999-08-31
A filter element is described for separating fine dirty particles from a hot gas. The filter element comprises a first porous wall and a second porous wall. Each porous wall has an outer surface and an inner surface. The first and second porous walls being coupled together thereby forming a substantially closed figure and open at one end. The open end is formed to be coupled to a hot gas clean up system support structure. The first and second porous walls define a channel beginning at the open end and terminate at the closed end through which a filtered clean gas can flow through and out into the clean gas side of a hot gas clean up system. 8 figs.
Granular Material Scoop and Near-Vertical Lifting Feeder/Conveyor
NASA Technical Reports Server (NTRS)
Walton, Otis (Inventor); Vollmer, Hubert J. (Inventor)
2017-01-01
An integrated granular-material scoop and near-vertical lifting feeder/conveyor includes special connections and skirts between a bullnose rotating scoop and an open-helical screw that provides the rotations and material lift and evacuation. A conical working-face of the bullnose rotating scoop has symmetrically distributed graters and vents to break loose and force-in granular material from natural deposits and cargo holds. The bullnose rotating scoop and the open-helical screw its attached to move the material into a continuous layer on the inside surface of an outer stationary sheathing. A motor drive attached to the open-helical screw above at the delivery end provides the lifting force necessary.
NASA Technical Reports Server (NTRS)
Ruiz, B. Ian; Burke, Gary R.; Lung, Gerald; Whitaker, William D.; Nowicki, Robert M.
2004-01-01
This viewgraph presentation reviews the architecture of the The CIA-AlA chip-set is a set of mixed-signal ASICs that provide a flexible high level interface between the spacecraft's command and data handling (C&DH) electronics and lower level functions in other spacecraft subsystems. Due to the open-systems architecture of the chip-set including an embedded micro-controller a variety of applications are possible. The chip-set was developed for the missions to the outer planets. The chips were developed to provide a single solution for both the switching and regulation of a spacecraft power bus. The Open-Systems Architecture allows for other powerful applications.
Mac-Thiong, Jean-Marc; Hilmi, Radwan; Roussouly, Pierre
2012-01-01
Study Design A retrospective study including 179 patients who underwent oblique lumbar interbody fusion (OLIF) at one institution. Purpose To report the complications associated with a minimally invasive technique of a retroperitoneal anterolateral approach to the lumbar spine. Overview of Literature Different approaches to the lumbar spine have been proposed, but they are associated with an increased risk of complications and a longer operation. Methods A total of 179 patients with previous posterior instrumented fusion undergoing OLIF were included. The technique is described in terms of: the number of levels fused, operative time and blood loss. Persurgical and postsurgical complications were noted. Results Patients were age 54.1 ± 10.6 with a BMI of 24.8 ± 4.1 kg/m2. The procedure was performed in the lumbar spine at L1-L2 in 4, L2-L3 in 54, L3-L4 in 120, L4-L5 in 134, and L5-S1 in 6 patients. It was done at 1 level in 56, 2 levels in 107, and 3 levels in 16 patients. Surgery time and blood loss were, respectively, 32.5 ± 13.2 minutes and 57 ± 131 ml per level fused. There were 19 patients with a single complication and one with two complications, including two patients with postoperative radiculopathy after L3-5 OLIF. There was no abdominal weakness or herniation. Conclusions Minimally invasive OLIF can be performed easily and safely in the lumbar spine from L2 to L5, and at L1-2 for selected cases. Up to 3 levels can be addressed through a 'sliding window'. It is associated with minimal blood loss and short operations, and with decreased risk of abdominal wall weakness or herniation. PMID:22708012
Surgical Navigation Technology Based on Augmented Reality and Integrated 3D Intraoperative Imaging
Elmi-Terander, Adrian; Skulason, Halldor; Söderman, Michael; Racadio, John; Homan, Robert; Babic, Drazenko; van der Vaart, Nijs; Nachabe, Rami
2016-01-01
Study Design. A cadaveric laboratory study. Objective. The aim of this study was to assess the feasibility and accuracy of thoracic pedicle screw placement using augmented reality surgical navigation (ARSN). Summary of Background Data. Recent advances in spinal navigation have shown improved accuracy in lumbosacral pedicle screw placement but limited benefits in the thoracic spine. 3D intraoperative imaging and instrument navigation may allow improved accuracy in pedicle screw placement, without the use of x-ray fluoroscopy, and thus opens the route to image-guided minimally invasive therapy in the thoracic spine. Methods. ARSN encompasses a surgical table, a motorized flat detector C-arm with intraoperative 2D/3D capabilities, integrated optical cameras for augmented reality navigation, and noninvasive patient motion tracking. Two neurosurgeons placed 94 pedicle screws in the thoracic spine of four cadavers using ARSN on one side of the spine (47 screws) and free-hand technique on the contralateral side. X-ray fluoroscopy was not used for either technique. Four independent reviewers assessed the postoperative scans, using the Gertzbein grading. Morphometric measurements of the pedicles axial and sagittal widths and angles, as well as the vertebrae axial and sagittal rotations were performed to identify risk factors for breaches. Results. ARSN was feasible and superior to free-hand technique with respect to overall accuracy (85% vs. 64%, P < 0.05), specifically significant increases of perfectly placed screws (51% vs. 30%, P < 0.05) and reductions in breaches beyond 4 mm (2% vs. 25%, P < 0.05). All morphometric dimensions, except for vertebral body axial rotation, were risk factors for larger breaches when performed with the free-hand method. Conclusion. ARSN without fluoroscopy was feasible and demonstrated higher accuracy than free-hand technique for thoracic pedicle screw placement. Level of Evidence: N/A PMID:27513166
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-28
... Drilling Program in the Chukchi Sea, Alaska AGENCY: National Marine Fisheries Service (NMFS), National... numbers of marine mammals, by harassment, incidental to conducting offshore exploration drilling on Outer... offshore exploration drilling on OCS leases in the Chukchi Sea, Alaska, during the 2014 open-water season...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-26
... Drilling Program in the Chukchi Sea, Alaska AGENCY: National Marine Fisheries Service (NMFS), National... conducting offshore exploration drilling on Outer Continental Shelf (OCS) leases in the Chukchi Sea, Alaska... incidental to COP's offshore exploration drilling in the Chukchi Sea during the 2014 open- [[Page 24732...
30 CFR 291.111 - How does MMS treat the confidential information I provide?
Code of Federal Regulations, 2010 CFR
2010-07-01
... INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL... a particular document is confidential. If you claim confidential treatment, then when you provide... that copy that you are making a request for confidential treatment for some or all of the information...
30 CFR 291.106 - How do I file a complaint?
Code of Federal Regulations, 2010 CFR
2010-07-01
....106 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT § 291.106 How do I... later than two (2) years from the time of the alleged access denial. If the complaint is filed later...
30 CFR 291.114 - How do I appeal to the IBLA?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 2 2011-07-01 2011-07-01 false How do I appeal to the IBLA? 291.114 Section 291.114 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER...
30 CFR 291.106 - How do I file a complaint?
Code of Federal Regulations, 2011 CFR
2011-07-01
... THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER... complaint. (d) Complaints shall not be filed later than two (2) years from the time of the alleged access denial. If the complaint is filed later than two (2) years from the time of the alleged access denial...
78 FR 14917 - Outer Continental Shelf Air Regulations Consistency Update for California
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-08
... and recordkeeping requirements, Sulfur oxides. Dated: November 21, 2012. Jared Blumenfeld, Regional... Sulfur Compounds (Adopted 06/14/94) Rule 56 Open Burning (Adopted 11/11/03) Rule 57 Incinerators (Adopted... Emissions (Adopted 11/21/78) Rule 64 Sulfur Content of Fuels (Adopted 04/13/99) Rule 67 Vacuum Producing...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Couture, P.A.
1984-08-21
The skylight may be of the domed-type or flat-type and of single or double glass (acrylic or other transparent or translucent plastic) construction. The skylight fits within an opening in a roof or the like and has a peripheral base that may be constructed of a metal material such as aluminum, and which is fixed to the roof about the opening. The base comprises inner and outer base frames separated by a thermal break, a peripheral curb frame disposed over the base, and a retainer for securing the skylight cover over the curb frame. The curb frame or support framemore » has inner and outer sections connected by a heat insulating thermal barrier. The curb frame is constructed by welding at the corners of the support frame but eliminating the welding in the area of the thermal barrier thus alleviating a caulking operation at the top and the bottom of the curb frame. The base frame and curb frame have therebetween a compliant sealing means extending contiguously about and overlying the base frame and for sealing between the base frame and support frame.« less
Parallelization strategies for continuum-generalized method of moments on the multi-thread systems
NASA Astrophysics Data System (ADS)
Bustamam, A.; Handhika, T.; Ernastuti, Kerami, D.
2017-07-01
Continuum-Generalized Method of Moments (C-GMM) covers the Generalized Method of Moments (GMM) shortfall which is not as efficient as Maximum Likelihood estimator by using the continuum set of moment conditions in a GMM framework. However, this computation would take a very long time since optimizing regularization parameter. Unfortunately, these calculations are processed sequentially whereas in fact all modern computers are now supported by hierarchical memory systems and hyperthreading technology, which allowing for parallel computing. This paper aims to speed up the calculation process of C-GMM by designing a parallel algorithm for C-GMM on the multi-thread systems. First, parallel regions are detected for the original C-GMM algorithm. There are two parallel regions in the original C-GMM algorithm, that are contributed significantly to the reduction of computational time: the outer-loop and the inner-loop. Furthermore, this parallel algorithm will be implemented with standard shared-memory application programming interface, i.e. Open Multi-Processing (OpenMP). The experiment shows that the outer-loop parallelization is the best strategy for any number of observations.
Sanit, Sangob; Sukontason, Kom; Kurahashi, Hiromu; Tomberlin, Jeffery K; Wannasan, Anchalee; Kraisittipanit, Rungroj; Sukontason, Kabkaew L
2017-12-01
Lucilia sinensis Aubertin (Diptera: Calliphoridae) is a blow fly species of potential forensic importance since adults are attracted to, and colonize, decomposing vertebrate remains. Blow fly larvae associated with human corpses can be useful evidence in forensic investigations; however, their use is dependent in most cases on proper species identification and availability of developmental data. For identification, morphological information on each life stage is traditionally used. We used scanning electron microscopy (SEM) to examine the ultrastructure of eggs, all instars, and puparia, of L. sinensis. The important characteristics used to differentiate L. sinensis from other species are provided. Distinctive features of the eggs are the slight widening median area extending almost the entire length. The last abdominal segment of the first instar bears elongated outer ventral tubercles along the rim of the last abdominal segment. These tubercles, as well as the well developed median and outer dorsal tubercles, are more prominent in the second and third instars. The surface integument of the tubercles is equipped with circular rows of microtrichia. Pairs of inner dorsal tubercle are absent. Each anterior spiracle is comprised of 9-12 papillae arrange in a single row in the second and third instars. As for the third instar, the dorsal spines between the first and second thoracic segments are delicate, narrow, small, and close together (as row or set). The peristigmatic tufts adjacent to the posterior spiracle of the third instar are moderately branches of short, fine hairs, but minute in puparia. In conclusion, the prominent outer ventral tubercle in all instars and puparia is a new diagnostic feature of L. sinensis and helpful in differentiating it from other Lucilia species that are forensically important. The description of immature L. sinensis in this study will be useful for forensic entomologists in countries where this species exists. Copyright © 2017 Elsevier B.V. All rights reserved.
Hippocampal Dendritic Spines Are Segregated Depending on Their Actin Polymerization
Domínguez-Iturza, Nuria; Calvo, María; Benoist, Marion; Esteban, José Antonio; Morales, Miguel
2016-01-01
Dendritic spines are mushroom-shaped protrusions of the postsynaptic membrane. Spines receive the majority of glutamatergic synaptic inputs. Their morphology, dynamics, and density have been related to synaptic plasticity and learning. The main determinant of spine shape is filamentous actin. Using FRAP, we have reexamined the actin dynamics of individual spines from pyramidal hippocampal neurons, both in cultures and in hippocampal organotypic slices. Our results indicate that, in cultures, the actin mobile fraction is independently regulated at the individual spine level, and mobile fraction values do not correlate with either age or distance from the soma. The most significant factor regulating actin mobile fraction was the presence of astrocytes in the culture substrate. Spines from neurons growing in the virtual absence of astrocytes have a more stable actin cytoskeleton, while spines from neurons growing in close contact with astrocytes show a more dynamic cytoskeleton. According to their recovery time, spines were distributed into two populations with slower and faster recovery times, while spines from slice cultures were grouped into one population. Finally, employing fast lineal acquisition protocols, we confirmed the existence of loci with high polymerization rates within the spine. PMID:26881098
Structural and functional plasticity of dendritic spines – root or result of behavior?
Gipson, Cassandra D.; Olive, M. Foster
2016-01-01
Dendritic spines are multifunctional integrative units of the nervous system and are highly diverse and dynamic in nature. Both internal and external stimuli influence dendritic spine density and morphology on the order of minutes. It is clear that the structural plasticity of dendritic spines is related to changes in synaptic efficacy, learning and memory, and other cognitive processes. However, it is currently unclear whether structural changes in dendritic spines are primary instigators of changes in specific behaviors, a consequence of behavioral changes, or both. In this review, we first review the basic structure and function of dendritic spines in the brain, as well as laboratory methods to characterize and quantify morphological changes in dendritic spines. We then discuss the existing literature on the temporal and functional relationship between changes in dendritic spines in specific brain regions and changes in specific behaviors mediated by those regions. Although technological advancements have allowed us to better understand the functional relevance of structural changes in dendritic spines that are influenced by environmental stimuli, the role of spine dynamics as an underlying driver or consequence of behavior still remains elusive. We conclude that while it is likely that structural changes in dendritic spines are both instigators and results of behavioral changes, improved research tools and methods are needed to experimentally and directly manipulate spine dynamics in order to more empirically delineate the relationship between spine structure and behavior. PMID:27561549
Fink, Howard A.; Harrison, Stephanie L.; Taylor, Brent C.; Cummings, Steven R.; Schousboe, John T.; Kuskowski, Michael A.; Stone, Katie L.; Ensrud, Kristine E.
2009-01-01
To examine the fracture pattern in older women whose bone mineral density (BMD) T-score criteria for osteoporosis at hip and spine disagree, hip and spine BMD were measured in Study of Osteoporotic Fractures participants using dual energy x-ray absorptiometry (DXA). Hip osteoporosis was defined as T-score ≤-2.5 at femoral neck or total hip, and spine osteoporosis as T-score ≤-2.5 at lumbar spine. Incident clinical fractures were self-reported and centrally adjudicated. Incident radiographic spine fractures were defined morphometrically. Compared to women with osteoporosis at neither hip nor spine, those osteoporotic only at hip had a 3.0-fold age and weight-adjusted increased risk for hip fracture (95%CI 2.4-3.6), and smaller increases in risk of nonhip nonspine (HR=1.6), clinical spine (OR=2.2), and radiographic spine fractures (OR=1.5). Women osteoporotic only at spine had a 2.8-fold increased odds of radiographic spine fracture (95%CI 2.1-3.8), and smaller increases in risk of clinical spine (OR=1.4), nonhip nonspine (HR=1.6), and hip fractures (HR=1.2). Discordant BMD results predict different fracture patterns. DXA fracture risk estimation in these patients should be site-specific. Women osteoporotic only at spine would not have been identified from hip BMD measurement alone, and may have a sufficiently high fracture risk to warrant preventive treatment. PMID:18296090
Active bypass flow control for a seal in a gas turbine engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ebert, Todd A.; Kimmel, Keith D.
An active bypass flow control system for controlling bypass compressed air based upon leakage flow of compressed air flowing past an outer balance seal between a stator and rotor of a first stage of a gas turbine in a gas turbine engine is disclosed. The active bypass flow control system is an adjustable system in which one or more metering devices may be used to control the flow of bypass compressed air as the flow of compressed air past the outer balance seal changes over time as the outer balance seal between the rim cavity and the cooling cavity wearsmore » In at least one embodiment, the metering device may include an annular ring having at least one metering orifice extending therethrough, whereby alignment of the metering orifice with the outlet may be adjustable to change a cross-sectional area of an opening of aligned portions of the outlet and the metering orifice.« less
Operation and postirradiation examination of ORR capsule OF-2: accelerated testing of HTGR fuel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tiegs, T.N.; Thoms, K.R.
1979-03-01
Irradiation capsule OF-2 was a test of High-Temperature Gas-Cooled Reactor fuel types under accelerated irradiation conditions in the Oak Ridge Research Reactor. The results showed good irradiation performance of Triso-coated weak-acid-resin fissile particles and Biso-coated fertile particles. These particles had been coated by a fritted gas distributor in the 0.13-m-diam furnace. Fast-neutron damage (E > 0.18 MeV) and matrix-particle interaction caused the outer pyrocarbon coating on the Triso-coated particles to fail. Such failure depended on the optical anisotropy, density, and open porosity of the outer pyrocarbon coating, as well as on the coke yield of the matrix. Irradiation of specimensmore » with values outside prescribed limits for these properties increased the failure rate of their outer pyrocarbon coating. Good irradiation performance was observed for weak-acid-resin particles with conversions in the range from 15 to 75% UC/sub 2/.« less
Experiences with tungsten coatings in high heat flux tests and under plasma load in ASDEX Upgrade
NASA Astrophysics Data System (ADS)
Herrmann, A.; Greuner, H.; Fuchs, J. C.; de Marné, P.; Neu, R.; ASDEX Upgrade Team
2009-12-01
ASDEX Upgrade was operated with about 6400 s plasma discharge during the scientific program in 2007/2008 exploring tungsten as a first wall material in tokamaks. In the first phase, the heating power was restricted to 10 MW. It was increased to 15 MW in the second phase. During this operational period, a delamination of the 200 μm W-VPS coating happened at 2 out of 128 tiles of the outer divertor and an unscheduled opening was required. In the third phase, ASDEX Upgrade was operated with partly predamaged tiles and up to 15 MW heating power. The target load was actively controlled by N2-seeding. This paper presents the screening test of target tiles in the high heat flux test facility GLADIS, experiences with operation and detected damages of the outer divertor as well as the heat load to the outer divertor and the reasons for the toroidal asymmetry of the divertor load.
FUEL ELEMENT FOR NUCLEAR REACTORS
Bassett, C.H.
1961-07-11
Nuclear reactor fuel elements of the type in which the flssionsble material is in ceramic form, such as uranium dioxide, are described. The fuel element is comprised of elongated inner and outer concentric spaced tubular members providing an annular space therebetween for receiving the fissionable material, the annular space being closed at both ends and the inner tube being open at both ends. The fuel is in the form of compressed pellets of ceramic fissionsble material having the configuration of split bushings formed with wedge surfaces and arranged in seriated inner and outer concentric groups which are urged against the respective tubes in response to relative axial movement of the pellets in the direction toward each other. The pairs of pellets are axially urged together by a resilient means also enclosed within the annulus. This arrangement-permits relative axial displacement of the pellets during use dial stresses on the inner and outer tube members and yet maintains the fuel pellets in good thermal conductive relationship therewith.
Open source IPSEC software in manned and unmanned space missions
NASA Astrophysics Data System (ADS)
Edwards, Jacob
Network security is a major topic of research because cyber attackers pose a threat to national security. Securing ground-space communications for NASA missions is important because attackers could endanger mission success and human lives. This thesis describes how an open source IPsec software package was used to create a secure and reliable channel for ground-space communications. A cost efficient, reproducible hardware testbed was also created to simulate ground-space communications. The testbed enables simulation of low-bandwidth and high latency communications links to experiment how the open source IPsec software reacts to these network constraints. Test cases were built that allowed for validation of the testbed and the open source IPsec software. The test cases also simulate using an IPsec connection from mission control ground routers to points of interest in outer space. Tested open source IPsec software did not meet all the requirements. Software changes were suggested to meet requirements.
Maxillofacial trauma - Underestimation of cervical spine injury.
Reich, Waldemar; Surov, Alexey; Eckert, Alexander Walter
2016-09-01
Undiagnosed cervical spine injury can have devastating results. The aim of this study was to analyse patients with primary maxillofacial trauma and a concomitant cervical spine injury. It is hypothetised that cervical spine injury is predictable in maxillofacial surgery. A monocentric clinical study was conducted over a 10-year period to analyse patients with primary maxillofacial and associated cervical spine injuries. Demographic data, mechanism of injury, specific trauma and treatments provided were reviewed. Additionally a search of relevant international literature was conducted in PubMed by terms "maxillofacial" AND "cervical spine" AND "injury". Of 3956 patients, n = 3732 (94.3%) suffered from craniomaxillofacial injuries only, n = 174 (4.4%) from cervical spine injuries only, and n = 50 (1.3%) from both craniomaxillofacial and cervical spine injuries. In this study cohort the most prevalent craniofacial injuries were: n = 41 (44%) midfacial and n = 21 (22.6%) skull base fractures. Cervical spine injuries primarily affected the upper cervical spine column: n = 39 (58.2%) vs. n = 28 (41.8%). Only in 3 of 50 cases (6%), the cervical spine injury was diagnosed coincidentally, and the cervical spine column was under immobilised. The operative treatment rate for maxillofacial injuries was 36% (n = 18), and for cervical spine injuries 20% (n = 10). The overall mortality rate was 8% (n = 4). The literature search yielded only 12 papers (11 retrospective and monocentric cohort studies) and is discussed before our own results. In cases of apparently isolated maxillofacial trauma, maxillofacial surgeons should be aware of a low but serious risk of underestimating an unstable cervical spine injury. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
The Rac-GAP alpha2-chimaerin regulates hippocampal dendrite and spine morphogenesis.
Valdez, Chris M; Murphy, Geoffrey G; Beg, Asim A
2016-09-01
Dendritic spines are fine neuronal processes where spatially restricted input can induce activity-dependent changes in one spine, while leaving neighboring spines unmodified. Morphological spine plasticity is critical for synaptic transmission and is thought to underlie processes like learning and memory. Significantly, defects in dendritic spine stability and morphology are common pathogenic features found in several neurodevelopmental and neuropsychiatric disorders. The remodeling of spines relies on proteins that modulate the underlying cytoskeleton, which is primarily composed of filamentous (F)-actin. The Rho-GTPase Rac1 is a major regulator of F-actin and is essential for the development and plasticity of dendrites and spines. However, the key molecules and mechanisms that regulate Rac1-dependent pathways at spines and synapses are not well understood. We have identified the Rac1-GTPase activating protein, α2-chimaerin, as a critical negative regulator of Rac1 in hippocampal neurons. The loss of α2-chimaerin significantly increases the levels of active Rac1 and induces the formation of aberrant polymorphic dendritic spines. Further, disruption of α2-chimaerin signaling simplifies dendritic arbor complexity and increases the presence of dendritic spines that appear poly-innervated. Our data suggests that α2-chimaerin serves as a "brake" to constrain Rac1-dependent signaling to ensure that the mature morphology of spines is maintained in response to network activity. Copyright © 2016 Elsevier Inc. All rights reserved.
49 CFR 572.85 - Lumbar spine flexure.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) of this section, the lumbar spine assembly shall flex by an amount that permits the thoracic spine to... to the thoracic spine box. Apply the force at any torso deflection rate between 0.5 and 1.5 degrees... 49 Transportation 7 2011-10-01 2011-10-01 false Lumbar spine flexure. 572.85 Section 572.85...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Opresko, Dennis M
A Hawaiian species of antipatharian coral previously identified as Antipathes dichotoma Pallas, 1766, is described as Antipathes griggi Opresko, n. sp. The species forms tall, bushy colonies with elongate, upright terminal branches, often arranged uniserially. Spines are conical, mostly 0.20 to 0.26 mm tall, apically bifurcated, multilobed to jagged in appearance, and covered over most of their surface with small roundish to elongate papillae. Minute secondary spines may occur on some of the thicker branches. Polyps are 1 to 1.6 mm in transverse diameter. The species resembles A. fruticosa Gray in branching pattern, size of spines, and presence of secondarymore » spines but differs in morphology and density of the spines (thicker, more crowded primary spines and fewer secondary spines in A. griggi). Other related species differ from A. griggi in having more widely spreading and irregularly arranged branches, no secondary spines, and either smaller spines with fewer apical lobes (A. curvata van Pesch, A. arborea Dana, and A. galapagensis Deichmann) or larger spines with the apical lobes arranged in a somewhat coronate pattern [A. spinulosa (Schultze) and A. lentipinna Brook].« less
Space science education based on the usage of microsatellites
NASA Astrophysics Data System (ADS)
Zaitzev, A.; Boyrchuk, K.; Panasuk, M.; Krasotkin, S.; Radchenko, V.; Fateev, V.; Tereshkov, A.
Lomonosov Moscow State University, Institute of Terrestrial Magnetism, Ionosphere and Radio Wave Propagation and Mozhaisky Engineering Space Forces Academy together with collaborators are planning to launch two microsatellites - "Kompas-Tatyana" and "Universitetsky" in 2004. In the Skobeltsyn Institute of Nuclear Physics of Moscow University the team of educators and students was formed in order to develop and to test the space science education program. The program includes few directions. First, the curriculum materials which include all basic knowledge regarding the operation of satellites in outer space. There are cover the telecommunications, navigation, and physical conditions in outer space, the instruments and related subjects. Second stage of the program includes some practical works with real satellite data. When satellite telemetry received, the data must be processed and quick-look graphs constructed. The main task for students in the second stage is the approach to the analysis and the comparison with the data that already exist. They will solve the tasks how to infer some original results from raw data and how to the received data corresponds to the models of outer space. Third, after analysis the students are expected to prepare the written reports and display the results on the open lessons in the web-page formats. The practical realization of the educational program is planned for "Kompas-Tatyana" and "Universitetsky" satellites which will be launched in the end of 2004. It will carry out several scientific instruments with telemetry in the 137 Mhz open channel. Students will able to receive the "live" telemetry data. Such practice is rather exiting and motivates them to work hard with the program tasks. The simple receiving devices will allow to get some data in the high schools as well. Additional support for teachers and students will be provided via main server in the Internet. The pilot version of curriculum materials will be tested on the databases available from other space experiments and microsatellites. Such data bases already exist in Internet and have open public access.
[Cervical spine instability in the surgical patient].
Barbeito, A; Guerri-Guttenberg, R A
2014-03-01
Many congenital and acquired diseases, including trauma, may result in cervical spine instability. Given that airway management is closely related to the movement of the cervical spine, it is important that the anesthesiologist has detailed knowledge of the anatomy, the mechanisms of cervical spine instability, and of the effects that the different airway maneuvers have on the cervical spine. We first review the normal anatomy and biomechanics of the cervical spine in the context of airway management and the concept of cervical spine instability. In the second part, we review the protocols for the management of cervical spine instability in trauma victims and some of the airway management options for these patients. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. All rights reserved.
Minimally Invasive Treatment for a Sacral Tarlov Cyst Through Tubular Retractors.
Del Castillo-Calcáneo, Juan D; Navarro-Ramírez, Rodrigo; Nakhla, Jonathan; Kim, Eliana; Härtl, Roger
2017-12-01
Tarlov cysts (TC) are focal dilations of arachnoid and dura mater of the spinal posterior nerve root sheath that appear as cystic lesions of the nerve roots typically in the lower spine, especially in the sacrum, which can cause radicular symptoms when they increase in size and compress the nerve roots. Different open procedures have been described to treat TCs, but no minimally invasive procedures have been described to effectively address this pathology. A 29-year-old woman presented with right lower extremity pain and weakness. A magnetic resonance imaging scan demonstrated a lumbosacral TC that protruded through the right L5-S1 foramina. Through a small laminotomy, cyst drainage followed by neck ligation using a Scanlan modified technique through tubular retractors was performed. The patient recovered full motor function within the first days postoperatively and showed no signs of relapse at 6-month follow-up. Minimally invasive spine surgery through tubular retractors can be safely performed for successful excision and ligation of TC using a Scanlan modified technique. Copyright © 2017 Elsevier Inc. All rights reserved.
Impingement around the hip: beyond cam and pincer
Bech, Niels Hendrik; Haverkamp, Daniel
2018-01-01
In this review, we bring to the attention of the reader three relatively unknown types of hip impingement. We explain the concept of low anterior inferior iliac spine (AIIS) impingement, also known as sub-spine impingement, ischio-femoral impingement (IFI) and pelvi-trochanteric impingement. For each type of impingement, we performed a search of relevant literature. We searched the PubMed, Medline (Ovid) and Embase databases from 1960 to March 2016. For each different type of impingement, a different search strategy was conducted. In total, 19 studies were included and described. No data analysis was performed since there was not much comparable data between studies. An overview of symptoms, clinical tests and possible surgical treatment options for the three different types of extra-articular impingement is provided. Several disorders around the hip can cause similar complaints. Therefore, we plead for a standardized classification. In young and athletic patients, in particular, there is much to gain if hip impingement is diagnosed early. Cite this article: EFORT Open Rev 2018;3:30-38. DOI: 10.1302/2058-5241.3.160068 PMID:29657843
Gkogkas, Christos G.; Khoutorsky, Arkady; Cao, Ruifeng; Jafarnejad, Seyed Mehdi; Prager-Khoutorsky, Masha; Giannakas, Nikolaos; Kaminari, Archontia; Fragkouli, Apostolia; Nader, Karim; Price, Theodore J.; Konicek, Bruce W.; Graff, Jeremy R.; Tzinia, Athina K.; Lacaille, Jean-Claude; Sonenberg, Nahum
2015-01-01
SUMMARY Fragile X syndrome (FXS) is the leading genetic cause of autism. Mutations in Fmr1 (fragile X mental retardation 1 gene) engender exaggerated translation resulting in dendritic spine dysmorphogenesis, synaptic plasticity alterations, and behavioral deficits in mice, which are reminiscent of FXS pheno-types. Using postmortem brains from FXS patients and Fmr1 knockout mice (Fmr1 −/y), we show that phosphorylation of the mRNA 5′ cap binding protein, eukaryotic initiation factor 4E (eIF4E), is elevated concomitant with increased expression of matrix metalloproteinase 9 (MMP-9) protein. Genetic or pharmacological reduction of eIF4E phosphorylation rescued core behavioral deficits, synaptic plasticity alterations, and dendritic spine morphology defects via reducing exaggerated translation of Mmp9 mRNA in Fmr1 −/y mice, whereas MMP-9 overexpression produced several FXS-like phenotypes. These results uncover a mechanism of regulation of synaptic function by translational control of Mmp-9 in FXS, which opens the possibility of new treatment avenues for the diverse neurological and psychiatric aspects of FXS. PMID:25466251
Sidhu, Harpreet; Dansie, Lorraine E.; Hickmott, Peter W.
2014-01-01
Fmr1 knock-out (ko) mice display key features of fragile X syndrome (FXS), including delayed dendritic spine maturation and FXS-associated behaviors, such as poor socialization, obsessive-compulsive behavior, and hyperactivity. Here we provide conclusive evidence that matrix metalloproteinase-9 (MMP-9) is necessary to the development of FXS-associated defects in Fmr1 ko mice. Genetic disruption of Mmp-9 rescued key aspects of Fmr1 deficiency, including dendritic spine abnormalities, abnormal mGluR5-dependent LTD, as well as aberrant behaviors in open field and social novelty tests. Remarkably, MMP-9 deficiency also corrected non-neural features of Fmr1 deficiency—specifically macroorchidism—indicating that MMP-9 dysregulation contributes to FXS-associated abnormalities outside the CNS. Further, MMP-9 deficiency suppressed elevations of Akt, mammalian target of rapamycin, and eukaryotic translation initiation factor 4E phosphorylation seen in Fmr1 ko mice, which are also associated with other autistic spectrum disorders. These findings establish that MMP-9 is critical to the mechanisms responsible for neural and non-neural aspects of the FXS phenotype. PMID:25057190
Krüger, Antonio; Baroud, Gamal; Noriega, David; Figiel, Jens; Dorschel, Christine; Ruchholtz, Steffen; Oberkircher, Ludwig
2013-08-01
Two different procedures, used for percutaneous augmentation of vertebral compression fractures were compared, with respect to height restoration and maintenance after cyclic loading. Additionally the impact of the cement volume used was investigated. Wedge compression fractures were created in 36 human cadavaric vertebrae (T10-L3). Twenty-seven vertebrae were treated with the SpineJack® with different cement volumes (maximum, intermediate, and no cement), and 9 vertebrae were treated with Balloon Kyphoplasty. Vertebral heights were measured pre- and postfracture as well as after treatment and loading. Cyclic loading was performed with 10,000cycles (1Hz, 100-600N). The average anterior height after restoration was 85.56% for Kyphoplasty; 96.20% for SpineJack® no cement; 93.44% for SpineJack® maximum and 96% for the SpineJack® intermediate group. The average central height after restoration was 93.89% for Kyphoplasty; 100.20% for SpineJack® no cement; 99.56% for SpineJack® maximum and 101.13% for the SpineJack® intermediate group. The average anterior height after cyclic loading was 85.33 % for Kyphoplasty; 87.30% in the SpineJack® no cement, 92% in the SpineJack® maximum and 87% in the SpineJack® intermediate group. The average central height after cyclic loading was 92% for Kyphoplasty; 93.80% in the SpineJack® no cement; 98.56% in the SpineJack® maximum and 94.25% in the SpineJack® intermediate group. Height restoration was significantly better for the SpineJack® group compared to Kyphoplasty. Height maintenance was dependent on the cement volume used. The group with the SpineJack® without cement nevertheless showed better results in height maintenance, yet the statistical significance could not be demonstrated. Copyright © 2013 Elsevier Ltd. All rights reserved.
Spatial and Working Memory Is Linked to Spine Density and Mushroom Spines
Aher, Yogesh D.; Sase, Ajinkya; Gröger, Marion; Mokhtar, Maher; Höger, Harald; Lubec, Gert
2015-01-01
Background Changes in synaptic structure and efficacy including dendritic spine number and morphology have been shown to underlie neuronal activity and size. Moreover, the shapes of individual dendritic spines were proposed to correlate with their capacity for structural change. Spine numbers and morphology were reported to parallel memory formation in the rat using a water maze but, so far, there is no information on spine counts or shape in the radial arm maze (RAM), a frequently used paradigm for the evaluation of complex memory formation in the rodent. Methods 24 male Sprague-Dawley rats were divided into three groups, 8 were trained, 8 remained untrained in the RAM and 8 rats served as cage controls. Dendritic spine numbers and individual spine forms were counted in CA1, CA3 areas and dentate gyrus of hippocampus using a DIL dye method with subsequent quantification by the Neuronstudio software and the image J program. Results Working memory errors (WME) and latency in the RAM were decreased along the training period indicating that animals performed the task. Total spine density was significantly increased following training in the RAM as compared to untrained rats and cage controls. The number of mushroom spines was significantly increased in the trained as compared to untrained and cage controls. Negative significant correlations between spine density and WME were observed in CA1 basal dendrites and in CA3 apical and basal dendrites. In addition, there was a significant negative correlation between spine density and latency in CA3 basal dendrites. Conclusion The study shows that spine numbers are significantly increased in the trained group, an observation that may suggest the use of this method representing a morphological parameter for memory formation studies in the RAM. Herein, correlations between WME and latency in the RAM and spine density revealed a link between spine numbers and performance in the RAM. PMID:26469788
NASA Technical Reports Server (NTRS)
Ferragut, Nelson J.
2005-01-01
A rugged iris mechanism has been designed to satisfy several special requirements, including a wide aperture in the "open" position, full obscuration in the "closed" position, ability to function in a cryogenic or other harsh environment, and minimization of friction through minimization of the number of components. An important element of the low-friction aspect of the design is maximization of the flatness of, and provision of small gaps between, adjacent iris blades. The tolerances of the design can be very loose, accommodating thermal expansions and contractions associated with large temperature excursions. The design is generic in that it is adaptable to a wide range of aperture sizes and can be implemented in a variety of materials to suit the thermal, optical, and mechanical requirements of various applications. The mechanism (see figure) includes an inner flat ring, an outer flat ring, and an even number of iris blades. The iris blades shown in front in the figure are denoted as "upper," and the iris blades shown partly hidden behind the front ones are denoted as "lower." Each iris blade is attached to the inner ring by a pivot assembly and to the outer ring by a roller/slider assembly. The upper and lower rings are co-centered and are kept in sliding contact. The iris is opened or closed by turning the outer ring around the center while holding the inner ring stationary. The mechanism is enclosed in a housing (not shown in the figure) that comprises an upper and a lower housing shell. The housing provides part of the sliding support for the outer ring and keeps the two rings aligned as described above. The aforementioned pivot assemblies at the inner ring also serve as spacers for the housing. The lower housing shell contains part of the lower sliding surface and features for mounting the overall mechanism and housing assembly. The upper housing shell contains part of the upper sliding surface.
Eisenbeis, Simone; Lohmiller, Stefanie; Valdebenito, Marianne; Leicht, Stefan; Braun, Volkmar
2008-08-01
Among the 67 predicted TonB-dependent outer membrane transporters of Caulobacter crescentus, NagA was found to be essential for growth on N-acetyl-beta-D-glucosamine (GlcNAc) and larger chitin oligosaccharides. NagA (93 kDa) has a predicted typical domain structure of an outer membrane transport protein: a signal sequence, the TonB box EQVVIT, a hatch domain of 147 residues, and a beta-barrel composed of 22 antiparallel beta-strands linked by large surface loops and very short periplasmic turns. Mutations in tonB1 and exbBD, known to be required for maltose transport via MalA in C. crescentus, and in two additional predicted tonB genes (open reading frames cc2327 and cc3508) did not affect NagA-mediated GlcNAc uptake. nagA is located in a gene cluster that encodes a predicted PTS sugar transport system and two enzymes that convert GlcNAc-6-P to fructose-6-P. Since a nagA insertion mutant did not grow on and transport GlcNAc, diffusion of GlcNAc through unspecific porins in the outer membrane is excluded. Uptake of GlcNAc into tonB and exbBD mutants and reduction but not abolishment of GlcNAc transport by agents which dissipate the electrochemical potential of the cytoplasmic membrane (0.1 mM carbonyl cyanide 3-chlorophenylhydrazone and 1 mM 2,4-dinitrophenol) suggest diffusion of GlcNAc through a permanently open pore of NagA. Growth on (GlcNAc)(3) and (GlcNAc)(5) requires ExbB and ExbD, indicating energy-coupled transport by NagA. We propose that NagA forms a small pore through which GlcNAc specifically diffuses into the periplasm and functions as an energy-coupled transporter for the larger chitin oligosaccharides.
... cervical spine; Computed tomography scan of cervical spine; CT scan of cervical spine; Neck CT scan ... table that slides into the center of the CT scanner. Once you are inside the scanner, the ...
Hierarchical structures of cactus spines that aid in the directional movement of dew droplets.
Malik, F T; Clement, R M; Gethin, D T; Kiernan, M; Goral, T; Griffiths, P; Beynon, D; Parker, A R
2016-08-06
Three species of cactus whose spines act as dew harvesters were chosen for this study: Copiapoa cinerea var. haseltoniana, Mammillaria columbiana subsp. yucatanensis and Parodia mammulosa and compared with Ferocactus wislizenii whose spines do not perform as dew harvesters. Time-lapse snapshots of C. cinerea showed movement of dew droplets from spine tips to their base, even against gravity. Spines emanating from one of the areoles of C. cinerea were submerged in water laced with fluorescent nanoparticles and this particular areole with its spines and a small area of stem was removed and imaged. These images clearly showed that fluorescent water had moved into the stem of the plant. Lines of vascular bundles radiating inwards from the surface areoles (from where the spines emanate) to the core of the stem were detected using magnetic resonance imaging, with the exception of F. wislizenii that does not harvest dew on its spines. Spine microstructures were examined using SEM images and surface roughness measurements (Ra and Rz) taken of the spines of C. cinerea It was found that a roughness gradient created by tapered microgrooves existed that could potentially direct surface water from a spine tip to its base.This article is part of the themed issue 'Bioinspired hierarchically structured surfaces for green science'. © 2016 The Author(s).
Dendritic spine geometry can localize GTPase signaling in neurons
Ramirez, Samuel A.; Raghavachari, Sridhar; Lew, Daniel J.
2015-01-01
Dendritic spines are the postsynaptic terminals of most excitatory synapses in the mammalian brain. Learning and memory are associated with long-lasting structural remodeling of dendritic spines through an actin-mediated process regulated by the Rho-family GTPases RhoA, Rac, and Cdc42. These GTPases undergo sustained activation after synaptic stimulation, but whereas Rho activity can spread from the stimulated spine, Cdc42 activity remains localized to the stimulated spine. Because Cdc42 itself diffuses rapidly in and out of the spine, the basis for the retention of Cdc42 activity in the stimulated spine long after synaptic stimulation has ceased is unclear. Here we model the spread of Cdc42 activation at dendritic spines by means of reaction-diffusion equations solved on spine-like geometries. Excitable behavior arising from positive feedback in Cdc42 activation leads to spreading waves of Cdc42 activity. However, because of the very narrow neck of the dendritic spine, wave propagation is halted through a phenomenon we term geometrical wave-pinning. We show that this can account for the localization of Cdc42 activity in the stimulated spine, and, of interest, retention is enhanced by high diffusivity of Cdc42. Our findings are broadly applicable to other instances of signaling in extreme geometries, including filopodia and primary cilia. PMID:26337387
Hierarchical structures of cactus spines that aid in the directional movement of dew droplets
Clement, R. M.; Gethin, D. T.; Kiernan, M.; Goral, T.; Griffiths, P.; Beynon, D.; Parker, A. R.
2016-01-01
Three species of cactus whose spines act as dew harvesters were chosen for this study: Copiapoa cinerea var. haseltoniana, Mammillaria columbiana subsp. yucatanensis and Parodia mammulosa and compared with Ferocactus wislizenii whose spines do not perform as dew harvesters. Time-lapse snapshots of C. cinerea showed movement of dew droplets from spine tips to their base, even against gravity. Spines emanating from one of the areoles of C. cinerea were submerged in water laced with fluorescent nanoparticles and this particular areole with its spines and a small area of stem was removed and imaged. These images clearly showed that fluorescent water had moved into the stem of the plant. Lines of vascular bundles radiating inwards from the surface areoles (from where the spines emanate) to the core of the stem were detected using magnetic resonance imaging, with the exception of F. wislizenii that does not harvest dew on its spines. Spine microstructures were examined using SEM images and surface roughness measurements (Ra and Rz) taken of the spines of C. cinerea. It was found that a roughness gradient created by tapered microgrooves existed that could potentially direct surface water from a spine tip to its base. This article is part of the themed issue ‘Bioinspired hierarchically structured surfaces for green science’. PMID:27354735
Contact pressure in the facet joint during sagittal bending of the cadaveric cervical spine.
Jaumard, Nicolas V; Bauman, Joel A; Weisshaar, Christine L; Guarino, Benjamin B; Welch, William C; Winkelstein, Beth A
2011-07-01
The facet joint contributes to the normal biomechanical function of the spine by transmitting loads and limiting motions via articular contact. However, little is known about the contact pressure response for this joint. Such information can provide a quantitative measure of the facet joint's local environment. The objective of this study was to measure facet pressure during physiologic bending in the cervical spine, using a joint capsule-sparing technique. Flexion and extension bending moments were applied to six human cadaveric cervical spines. Global motions (C2-T1) were defined using infra-red cameras to track markers on each vertebra. Contact pressure in the C5-C6 facet was also measured using a tip-mounted pressure transducer inserted into the joint space through a hole in the postero-inferior region of the C5 lateral mass. Facet contact pressure increased by 67.6 ± 26.9 kPa under a 2.4 Nm extension moment and decreased by 10.3 ± 9.7 kPa under a 2.7 Nm flexion moment. The mean rotation of the overall cervical specimen motion segments was 9.6 ± 0.8° and was 1.6 ± 0.7° for the C5-C6 joint, respectively, for extension. The change in pressure during extension was linearly related to both the change in moment (51.4 ± 42.6 kPa/Nm) and the change in C5-C6 angle (18.0 ± 108.9 kPa/deg). Contact pressure in the inferior region of the cervical facet joint increases during extension as the articular surfaces come in contact, and decreases in flexion as the joint opens, similar to reports in the lumbar spine despite the difference in facet orientation in those spinal regions. Joint contact pressure is linearly related to both sagittal moment and spinal rotation. Cartilage degeneration and the presence of meniscoids may account for the variation in the pressure profiles measured during physiologic sagittal bending. This study shows that cervical facet contact pressure can be directly measured with minimal disruption to the joint and is the first to provide local pressure values for the cervical joint in a cadaveric model.
Paggiosi, M A; Peel, N; McCloskey, E; Walsh, J S; Eastell, R
2014-12-01
We compared the effects of oral alendronate, ibandronate and risedronate on the central and peripheral skeleton over 2 years. We report differences in effect on the central skeleton but not on the peripheral skeleton. Greater effects were observed for ibandronate (and alendronate) than risedronate at the spine but not the hip. Generally, comparative clinical trials of bisphosphonates have examined changes in bone within central skeletal regions. We have examined the effects of bisphosphonate treatment on the peripheral skeleton. We conducted a 2-year, open-label, parallel randomised control trial of three orally administered bisphosphonates, at their licensed dose, to examine and compare their effects on the peripheral skeleton using multiple modes of measurement. We studied 172 postmenopausal women (53-84 years) who had either a bone mineral density (BMD) T-score of ≤ -2.5 at the spine and/or total hip or < -1.0 at either site plus a previous low trauma fracture. Participants were randomised to receive either (i) ibandronate 150 mg/month, (ii) alendronate 70 mg/week or (iii) risedronate 35 mg/week, plus calcium (1,200 mg/day) and vitamin D (800 IU/day), for 2 years. Premenopausal women (33-40 years, n = 226) were studied to monitor device stability. We measured central BMD of the lumbar spine, total hip, total body and forearm using dual-energy X-ray absorptiometry. We measured calcaneus BMD (using dual-energy X-ray absorptiometry plus laser), radius and tibia BMD (using peripheral quantitative computed tomography), finger BMD (using radiographic absorptiometry), and phalangeal and calcaneal ultrasound variables (using quantitative ultrasound). Mixed effects regression models were used to evaluate effects of time and treatment allocation on BMD change. By 2 years, there were significant increases (p < 0.05) in central BMD sites (lumbar spine, total hip). In the peripheral skeleton, only significant changes in calcaneus BMD, 33 % total radius BMD and quantitative ultrasound (QUS)-2 broadband ultrasound attenuation (BUA) were evident for women receiving oral bisphosphonates. The increases in lumbar spine and total body BMD were greater with ibandronate and alendronate than with risedronate. Treatment effects on peripheral measurements did not differ between the three bisphosphonates.
Nguyen, Ha Son; Choi, Hoon; Kurpad, Shekar; Soliman, Hesham
2017-09-01
Traumatic spinal subdural hematoma involving the retroclival region and upper cervical spine is a rare pathology. To our knowledge, there have only been 2 prior cases in an adult trauma patient. We describe a patient with preexisting Chiari 1 malformation, who recently sustained a unilateral type 1 occipital condyle fracture with associated disruption of the tectorial membrane and transverse ligament, which returned with a retroclival subdural hematoma extending down to C7, causing spinal cord compression and symptomatic obstructive hydrocephalus. A 30-year-old female sustained a motor vehicle collision. Computed tomography C spine revealed a type I occipital condyle fracture. Magnetic resonance imaging C spine demonstrated disruption of the tectorial membrane and avulsion of the transverse ligament at its attachment to the left C1 tubercle; moreover, there was a Chiari 1 malformation. The patient was neurologically intact. A halo was recommended, but the patient opted for an aspen collar with close management. She was discharged but returned 3 days later with apneic episodes, along with bradycardia and hypertension. She was promptly intubated. Computed tomography head showed interval ventricular enlargement. Magnetic resonance imaging C spine revealed a new ventral hematoma spanning the retroclival region to C7, most pronounced at C2-C3. On examination, she opened her eyes to pain, her pupils were equal and reactive, and she withdrew in all extremities. An external ventricular drain was emergently placed. She underwent a suboccipital craniectomy, C1-3 laminectomies, and occiput-C4 instrumented fusion. The dura was significantly tense, and no epidural hematoma was observed during lateral exploration. Postoperatively, she woke up well, exhibiting a nonfocal neurologic examination. A diagnostic angiogram was negative. She was extubated uneventfully, and the external ventricular drain was weaned off in 4 days. Traumatic spinal subdural hematoma involving both the retroclival region and upper cervical spine can lead to bulbar signs and symptomatic obstructive hydrocephalus. There should be vigilance for this pathology in patients with high-energy craniocervical trauma. Disruption of the tectorial membrane and therapeutic anticoagulation may be risk factors. The clinical scenario can be complicated in the setting of a preexisting Chiari 1 malformation. Copyright © 2017 Elsevier Inc. All rights reserved.
Ratfish (Chimaera) spine injuries in fishermen.
Hayes, A J; Sim, A J W
2011-08-01
An occupational hazard peculiar to fishermen, is an injury from a sharp fish spine. Such spines can cause envenomation injury, infectious sequelae or trauma to anatomical structures. The management of two fishermen with penetrating ratfish (Chimaera) spine injuries to the lower limb is described. Both were managed by removal of the spine under general anaesthesia. In the second patient, the spine was embedded adjacent to the left femoral artery, highlighting the potential for major haemorrhage and supporting the use of surgical wound exploration when important structures may be involved. Herein, we describe the first report in English of Chimaera spine injury. In addition, we surveyed nine northeast Atlantic deep-sea fishermen to gain information on exposure to, and injuries from, this type of fish. The most commonly identified species was Chimaera monstrosa. Five fishermen reported injuries to their feet or hands from Chimaera spines and two had sought medical attention. The evidence indicates that deep-sea trawler fishermen of the northeast Atlantic frequently encounter Chimaera species and can suffer dangerous penetrating wounds from its dorsal spine.
Lynx1 Limits Dendritic Spine Turnover in the Adult Visual Cortex
Sajo, Mari
2016-01-01
Dendritic spine turnover becomes limited in the adult cerebral cortex. Identification of specific aspects of spine dynamics that can be unmasked in adulthood and its regulatory molecular mechanisms could provide novel therapeutic targets for inducing plasticity at both the functional and structural levels for robust recovery from brain disorders and injuries in adults. Lynx1, an endogenous inhibitor of nicotinic acetylcholine receptors, was previously shown to increase its expression in adulthood and thus to limit functional ocular dominance plasticity in adult primary visual cortex (V1). However, the role of this “brake” on spine dynamics is not known. We examined the contribution of Lynx1 on dendritic spine turnover before and after monocular deprivation (MD) in adult V1 with chronic in vivo imaging using two-photon microscopy and determined the spine turnover rate of apical dendrites of layer 5 (L5) and L2/3 pyramidal neurons in adult V1 of Lynx1 knock-out (KO) mice. We found that the deletion of Lynx1 doubled the baseline spine turnover rate, suggesting that the spine dynamics in the adult cortex is actively limited by the presence of Lynx1. After MD, adult Lynx1-KO mice selectively exhibit higher rate of spine loss with no difference in gain rate in L5 neurons compared with control wild-type counterparts, revealing a key signature of spine dynamics associated with robust functional plasticity in adult V1. Overall, Lynx1 could be a promising therapeutic target to induce not only functional, but also structural plasticity at the level of spine dynamics in the adult brain. SIGNIFICANCE STATEMENT Dendritic spine turnover becomes limited in the adult cortex. In mouse visual cortex, a premier model of experience-dependent plasticity, we found that the deletion of Lynx1, a nicotinic “brake” for functional plasticity, doubled the baseline spine turnover in adulthood, suggesting that the spine dynamics in the adult cortex is actively limited by Lynx1. After visual deprivation, spine loss, but not gain rate, remains higher in adult Lynx1 knock-out mice than in control wild-type mice, revealing a key signature of spine dynamics associated with robust functional plasticity. Lynx1 would be a promising target to induce not only functional, but also structural plasticity at the level of spine dynamics in adulthood. PMID:27605620
CAT scan - lumbar spine; Computed axial tomography scan - lumbar spine; Computed tomography scan - lumbar spine; CT - lower back ... CT scans rapidly makes detailed pictures of the lower back. The test may be used to look for: ...
Aquatic antagonists: cutaneous sea urchin spine injury.
Hsieh, Clifford; Aronson, Erica R; Ruiz de Luzuriaga, Arlene M
2016-11-01
Injuries from sea urchin spines are commonly seen in coastal regions with high levels of participation in water activities. Although these injuries may seem minor, the consequences vary based on the location of the injury. Sea urchin spine injuries may cause arthritis and synovitis from spines in the joints. Nonjoint injuries have been reported, and dermatologic aspects of sea urchin spine injuries rarely have been discussed. We present a case of a patient with sea urchin spines embedded in the thigh who subsequently developed painful skin nodules. Tissue from the site of the injury demonstrated foreign-body type granulomas. Following the removal of the spines and granulomatous tissue, the patient experienced resolution of the nodules and associated pain. Extraction of sea urchin spines can attenuate the pain and decrease the likelihood of granuloma formation, infection, and long-term sequelae.
Ka, Minhan; Kook, Yeon-Hee; Liao, Ke; Buch, Shilpa; Kim, Woo-Yang
2016-01-01
Cocaine is a highly addictive narcotic associated with dendritic spine plasticity in the striatum. However, it remains elusive whether cocaine modifies spines in a cell type-specific or region-specific manner or whether it alters different types of synapses in the brain. In addition, there is a paucity of data on the regulatory mechanism(s) involved in cocaine-induced modification of spine density. In the current study, we report that cocaine exposure differentially alters spine density, spine morphology, and the types of synapses in hippocampal and cortical neurons. Cocaine exposure in the hippocampus resulted in increased spine density, but had no significant effect on cortical neurons. Although cocaine exposure altered spine morphology in both cell types, the patterns of spine morphology were distinct for each cell type. Furthermore, we observed that cocaine selectively affects the density of excitatory synapses. Intriguingly, in hippocampal neurons cocaine-mediated effects on spine density and morphology involved sigma-1 receptor (Sig-1 R) and its downstream TrkB signaling, which were not the case in cortical neurons. Furthermore, pharmacological inhibition of Sig-1 R prevented cocaine-induced TrkB activation in hippocampal neurons. Our findings reveal a novel mechanism by which cocaine induces selective changes in spine morphology, spine density, and synapse formation, and could provide insights into the cellular basis for the cognitive impairment observed in cocaine addicts. PMID:27735948
Probing the Interplay between Dendritic Spine Morphology and Membrane-Bound Diffusion.
Adrian, Max; Kusters, Remy; Storm, Cornelis; Hoogenraad, Casper C; Kapitein, Lukas C
2017-11-21
Dendritic spines are protrusions along neuronal dendrites that harbor the majority of excitatory postsynapses. Their distinct morphology, often featuring a bulbous head and small neck that connects to the dendritic shaft, has been shown to facilitate compartmentalization of electrical and cytoplasmic signaling stimuli elicited at the synapse. The extent to which spine morphology also forms a barrier for membrane-bound diffusion has remained unclear. Recent simulations suggested that especially the diameter of the spine neck plays a limiting role in this process. Here, we examine the connection between spine morphology and membrane-bound diffusion through a combination of photoconversion, live-cell superresolution experiments, and numerical simulations. Local photoconversion was used to obtain the timescale of diffusive equilibration in spines and followed by global sparse photoconversion to determine spine morphologies with nanoscopic resolution. These morphologies were subsequently used to assess the role of morphology on the diffusive equilibration. From the simulations, we could determine a robust relation between the equilibration timescale and a generalized shape factor calculated using both spine neck width and neck length, as well as spine head size. Experimentally, we found that diffusive equilibration was often slower, but rarely faster than predicted from the simulations, indicating that other biological confounders further reduce membrane-bound diffusion in these spines. This shape-dependent membrane-bound diffusion in mature spines may contribute to spine-specific compartmentalization of neurotransmitter receptors and signaling molecules and thereby support long-term plasticity of synaptic contacts. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Conspicuous and aposematic spines in the animal kingdom
NASA Astrophysics Data System (ADS)
Inbar, Moshe; Lev-Yadun, Simcha
2005-04-01
Spines serve as a common physical defence mechanism in both the plant and animal kingdoms. Here we argue that as in plants, defensive animal spines are often conspicuous (shape and colour) and should be considered aposematic. Conspicuous spines may evolve as signals or serve as a cue for potential predators. Spine conspicuousness in animals has evolved independently across and within phyla occupying aquatic and terrestrial ecosystems, indicating that this convergent phenomenon is highly adaptive. Still, many spines are cryptic, suggesting that conspicuity is not simply constrained by developmental factors such as differences in the chemical composition of the integument. Aposematism does not preclude the signalling role of conspicuous spines in the sexual arena.
Clearing the Cervical Spine in a War Zone: What Other Injuries Matter?
2015-07-01
Defense Trauma Registry January 2008 to August 2013, identifying blunt trauma patients with cervical spine injury and Glasgow Coma Score > 14...negative clinical examination of the cervical spine . Coexisting injuries identified in patients with negative physical examination included...distracting injuries were present, the physical examination was accurate in all patients. 15. SUBJECT TERMS Cervical spine clearance; cervical spine
Fifty top-cited spine articles from mainland China: A citation analysis.
Wu, Yaohong; Zhao, Yachao; Lin, Linghan; Lu, Zhijun; Guo, Zhaoyang; Li, Xiaoming; Chen, Rongchun; Ma, Huasong
2018-02-01
Objective To identify the 50 top-cited spine articles from mainland China and to analyze their main characteristics. Methods Web of Science was used to identify the 50 top-cited spine articles from mainland China in 27 spine-related journals. The title, year of publication, number of citations, journal, anatomic focus, subspecialty, evidence level, city, institution and author were recorded. Results The top 50 articles had 29-122 citations and were published in 11 English-language journals; most (32) were published in the 2000s. The journal Spine had the largest number of articles and The Lancet had the highest impact factor. The lumber spine was the most discussed anatomic area (18). Degenerative spine disease was the most common subspecialty topic (22). Most articles were clinical studies (29); the others were basic research (21). Level IV was the most common evidence level (17). Conclusions This list indicates the most influential articles from mainland China in the global spine research community. Identification of these articles provides insights into the trends in spine care in mainland China and the historical contributions of researchers from mainland China to the international spine research field.
Changing views of Cajal's neuron: the case of the dendritic spine.
Segal, Menahem
2002-01-01
Ever since dendritic spines were first described in detail by Santiago Ramón y Cajal, they were assumed to underlie the physical substrate of long term memory in the brain. Recent time-lapse imaging of dendritic spines in live tissue, using confocal microscopy, have revealed an amazingly plastic structure, which undergoes continuous changes in shape and size, not intuitively related to its assumed role in long term memory. Functionally, the spine is shown to be an independent cellular compartment, able to regulate calcium concentration independently of its parent dendrite. The shape of the spine is instrumental in regulating the link between the synapse and the parent dendrite such that longer spines have less impact on the dendrite than shorter ones. The spine can be formed, change its shape and disappear in response to afferent stimulation, in a dynamic fashion, indicating that spine morphology is an important vehicle for structuring synaptic interactions. While this role is crucial in the developing nervous system, large variations in spine densities in the adult brain indicate that tuning of synaptic impact may be a role of spines throughout the life of a neuron.
Extracellular matrix control of dendritic spine and synapse structure and plasticity in adulthood
Levy, Aaron D.; Omar, Mitchell H.; Koleske, Anthony J.
2014-01-01
Dendritic spines are the receptive contacts at most excitatory synapses in the central nervous system. Spines are dynamic in the developing brain, changing shape as they mature as well as appearing and disappearing as they make and break connections. Spines become much more stable in adulthood, and spine structure must be actively maintained to support established circuit function. At the same time, adult spines must retain some plasticity so their structure can be modified by activity and experience. As such, the regulation of spine stability and remodeling in the adult animal is critical for normal function, and disruption of these processes is associated with a variety of late onset diseases including schizophrenia and Alzheimer’s disease. The extracellular matrix (ECM), composed of a meshwork of proteins and proteoglycans, is a critical regulator of spine and synapse stability and plasticity. While the role of ECM receptors in spine regulation has been extensively studied, considerably less research has focused directly on the role of specific ECM ligands. Here, we review the evidence for a role of several brain ECM ligands and remodeling proteases in the regulation of dendritic spine and synapse formation, plasticity, and stability in adults. PMID:25368556
Jia, Zhiwei; Wu, Yaohong; Tang, Yong; Ji, Wei; Li, Wei; Zhao, Xiyan; Li, Hao; He, Qing; Ruan, Dike
2016-03-01
The practice of giving certain authors equal credit in scientific publications has become increasingly common in some medical specialties. However, whether this trend also exists in major spine journals remains unclear. This study aimed to investigate the prevalence and characteristics of the practice of giving authors equal credit in major spine journals. Manual searches were performed to identify original research articles with equally credited authors (ECA) published between January 1, 2004 and December 31, 2013 in three major spine journals: Spine, European Spine Journal, and The Spine Journal. The number of authors with ECA and their positions in the byline, total number of authors, year of publication, and country of origin were analysed. The practice of ECA was found in all three journals. Articles with ECA comprised a greater proportion of the total number of publications in each journal in 2013 versus 2004 (Spine, 7.2 vs. 0.2%; European Spine Journal, 7.5 vs. 0.0%; and The Spine Journal, 6.2 vs. 0.0%). There was a statistically significant increasing trend in the annual proportion of papers with ECA for all three spine journals (p < 0.0001). The practice of ECA was applied in nearly every position in the byline, and the first two authors received equal credit in most cases. Articles with ECA were published by authors from various countries and regions around the world. However, none of the three spine journals provided specific guidance on this practice in their author instructions. The practice of ECA in original research articles is increasingly common in major spine journals. A guideline for authors regarding when and how to designate equal credit is warranted in the future.
Nikolić, Slobodan; Zivković, Vladimir
2014-06-01
The incidence of cervical spine injuries in suicidal hangings with a short-drop has been reported to be extremely low or non-existent. The aim of this study was to determine the frequency and pattern of cervical spine injuries in suicidal hanging. A retrospective autopsy study was performed and short-drop suicidal hanging cases with documented cervical spine injuries were identified. This group was further analyzed with regard to the gender and age of the deceased, the position of the ligature knot, the presence of hyoid-laryngeal fractures, and the level of cervical spine injury. Cervical spine injuries were present in 25 of the 766 cases, with an average age of 71.9 ± 10.7 years (range 39-88 years). In 16 of these 25 cases, the ligature knot was in the anterior position. The most common pattern of cervical spine injury included partial or complete disruption of the anterior longitudinal ligament and widening of the lower cervical spine disk spaces, associated with absence of hyoid-laryngeal fractures. Cervical spine injuries are not commonly found in short-drop suicidal hanging, occurring in only 3.3 % of all observed cases. Cervical spine injury may be occurring in 80 % of subjects aged 66.5 years and above. The most common pattern of cervical spine injury included anterior longitudinal ligament disruption of the lower cervical spine, disk space widening, and no vertebral body displacement. These injuries were mainly associated with an anterior knot position, and may be a consequence of loop pressure to the posterior neck and cervical spine hyperextension.
Sing, David C; Metz, Lionel N; Dudli, Stefan
2017-06-01
Retrospective review. To identify the top 100 spine research topics. Recent advances in "machine learning," or computers learning without explicit instructions, have yielded broad technological advances. Topic modeling algorithms can be applied to large volumes of text to discover quantifiable themes and trends. Abstracts were extracted from the National Library of Medicine PubMed database from five prominent peer-reviewed spine journals (European Spine Journal [ESJ], The Spine Journal [SpineJ], Spine, Journal of Spinal Disorders and Techniques [JSDT], Journal of Neurosurgery: Spine [JNS]). Each abstract was entered into a latent Dirichlet allocation model specified to discover 100 topics, resulting in each abstract being assigned a probability of belonging in a topic. Topics were named using the five most frequently appearing terms within that topic. Significance of increasing ("hot") or decreasing ("cold") topic popularity over time was evaluated with simple linear regression. From 1978 to 2015, 25,805 spine-related research articles were extracted and classified into 100 topics. Top two most published topics included "clinical, surgeons, guidelines, information, care" (n = 496 articles) and "pain, back, low, treatment, chronic" (424). Top two hot trends included "disc, cervical, replacement, level, arthroplasty" (+0.05%/yr, P < 0.001), and "minimally, invasive, approach, technique" (+0.05%/yr, P < 0.001). By journal, the most published topics were ESJ-"operative, surgery, postoperative, underwent, preoperative"; SpineJ-"clinical, surgeons, guidelines, information, care"; Spine-"pain, back, low, treatment, chronic"; JNS- "tumor, lesions, rare, present, diagnosis"; JSDT-"cervical, anterior, plate, fusion, ACDF." Topics discovered through latent Dirichlet allocation modeling represent unbiased meaningful themes relevant to spine care. Topic dynamics can provide historical context and direction for future research for aspiring investigators and trainees interested in spine careers. Please explore https://singdc.shinyapps.io/spinetopics. N A.
Jaumard, Nicolas V; Leung, Jennifer; Gokhale, Akhilesh J; Guarino, Benjamin B; Welch, William C; Winkelstein, Beth A
2015-10-15
Basic science study measuring anatomical features of the cervical and lumbar spine in rat with normalized comparison with the human. The goal of this study is to comprehensively compare the rat and human cervical and lumbar spines to investigate whether the rat is an appropriate model for spine biomechanics investigations. Animal models have been used for a long time to investigate the effects of trauma, degenerative changes, and mechanical loading on the structure and function of the spine. Comparative studies have reported some mechanical properties and/or anatomical dimensions of the spine to be similar between various species. However, those studies are largely limited to the lumbar spine, and a comprehensive comparison of the rat and human spines is lacking. Spines were harvested from male Holtzman rats (n = 5) and were scanned using micro- computed tomography and digitally rendered in 3 dimensions to quantify the spinal bony anatomy, including the lateral width and anteroposterior depth of the vertebra, vertebral body, and spinal canal, as well as the vertebral body and intervertebral disc heights. Normalized measurements of the vertebra, vertebral body, and spinal canal of the rat were computed and compared with corresponding measurements from the literature for the human in the cervical and lumbar spinal regions. The vertebral dimensions of the rat spine vary more between spinal levels than in humans. Rat vertebrae are more slender than human vertebrae, but the width-to-depth axial aspect ratios are very similar in both species in both the cervical and lumbar regions, especially for the spinal canal. The similar spinal morphology in the axial plane between rats and humans supports using the rat spine as an appropriate surrogate for modeling axial and shear loading of the human spine.
Nayar, Gautam; Wang, Timothy; Sankey, Eric W; Berry-Candelario, John; Elsamadicy, Aladine A; Back, Adam; Karikari, Isaac; Isaacs, Robert
2018-05-19
Risk factors for surgical revision remain important because of additional readmission, anesthesia, and morbidity for the patient and significant cost for health care systems. Although the rate of reoperation (RRO) is well described for traditional open posterior (OP) approaches, the RRO in minimally invasive lateral (MIL) surgery remains poorly characterized. This study compares the RRO in patients undergoing decompressive lumbar spine surgery via MIL versus OP approaches. Patient demographics and comorbidities were retrospectively collected for 2060 patients undergoing single-stage elective lumbar spinal surgery at multiple institutions. A subset of 1484 patients had long-term data (long-term cohort [LT cohort]). The RRO was compared between approaches through univariate and multivariate analysis. There were 1292 patients (62.7%) who underwent lateral access surgery, whereas 768 patients (37.3%) underwent OP surgery. The MIL cohort was significantly older, had a higher proportion of men, and had more comorbidities than the OP cohort. In the LT cohort, lateral patients were significantly older and had more comorbidities, with a lower body mass index and a lower proportion of men and smokers. Surgical complications between the groups trended to be similar. The MIL cohort had a significantly lower RRO at both 30 days (approximately 57% lower, MIL cohort: 1.01% vs. OP cohort: 2.36%, P = 0.02) and 2 years (approximately 61% lower, MIL cohort: 2.09% vs. OP cohort: 5.37%, P < 0.01) after surgery. On multivariate analysis, surgical approach was the only significant predictor for the RRO at both 30 days (open posterior approach odds ratio [OR], 4.47; 95% confidence interval [CI], 1.33-15.09; P = 0.02) and 2 years (open posterior approach OR, 3.26; 95% CI, 1.26-8.42; P = 0.01). This study shows that MIL surgical approaches, compared with OP approaches, have a significantly lower RRO after lumbar spine surgery. Copyright © 2018 Elsevier Inc. All rights reserved.
Dual annular rotating [open quotes]windowed[close quotes] nuclear reflector reactor control system
Jacox, M.G.; Drexler, R.L.; Hunt, R.N.M.; Lake, J.A.
1994-03-29
A nuclear reactor control system is provided in a nuclear reactor having a core operating in the fast neutron energy spectrum where criticality control is achieved by neutron leakage. The control system includes dual annular, rotatable reflector rings. There are two reflector rings: an inner reflector ring and an outer reflector ring. The reflectors are concentrically assembled, surround the reactor core, and each reflector ring includes a plurality of openings. The openings in each ring are capable of being aligned or non-aligned with each other. Independent driving means for each of the annular reflector rings is provided so that reactor criticality can be initiated and controlled by rotation of either reflector ring such that the extent of alignment of the openings in each ring controls the reflection of neutrons from the core. 4 figures.
High-density, fail-in-place switches for computer and data networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coteus, Paul W.; Doany, Fuad E.; Hall, Shawn A.
A structure for a network switch. The network switch may include a plurality of spine chips arranged on a plurality of spine cards, where one or more spine chips are located on each spine card; and a plurality of leaf chips arranged on a plurality of leaf cards, wherein one or more leaf chips are located on each leaf card, where each spine card is connected to every leaf chip and the plurality of spine chips are surrounded on at least two sides by leaf cards.
Holding fixture for metallographic mount polishing
Barth, Clyde H.; Cramer, Charles E.
1997-01-01
A fixture for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface.
30 CFR 291.114 - How do I appeal to the IBLA?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I appeal to the IBLA? 291.114 Section 291.114 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT § 291.114 How do I...
30 CFR 291.109 - Can I ask for a fee waiver or a reduced processing fee?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Can I ask for a fee waiver or a reduced processing fee? 291.109 Section 291.109 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL...
30 CFR 291.107 - How do I answer a complaint?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 2 2010-07-01 2010-07-01 false How do I answer a complaint? 291.107 Section 291.107 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR APPEALS OPEN AND NONDISCRIMINATORY ACCESS TO OIL AND GAS PIPELINES UNDER THE OUTER CONTINENTAL SHELF LANDS ACT § 291.107 How do I...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-24
... Western Planning Area (WPA) Lease Sale 233 and Central Planning Area (CPA) Lease Sale 231 (WPA/CPA... is reopening the scoping comment period. DATES: Scoping comments for this Draft WPA/CPA Supplemental...-opening of the scoping process for the WPA/CPA Supplemental EIS. Throughout the scoping process, Federal...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, J.C.; Reiss, R.J.; Rica, A.F.
There is disclosed an aseptic flexible walled container having a rigid fitment member cooperative with an aseptic filling apparatus and including a neck, outer flanges surrounding the neck, a frangible membrane and an outer end rim receptive of an hermetically sealed lid. The neck is formed with an internal chamferred seating shoulder for fluid-tight engagement with a fill tube. One outer flange cooperates with clamping jaws of the aseptic filling apparatus for detachably sealing the fitment to a sterilizing chamber and placing it in position for insertion of the filling tube which ruptures the membrane and permits the aseptic introductionmore » of product to the container's interior. The other outer flange is secured to an opening in a wall of the flexible container. The joined fitment and container are presterilized prior to filling. Selected materials for the multi-ply container walls and the fitment permit the container to withstand gamma ray and other sterilization treatment, heat and pressure while maintaining required strength. After the container is aseptically filled, such as with flowable food product, the fill tube is withdrawn and a lid is hermetically sealed onto the rim of the fitment. A heat shield adjacent a container wall surrounds the fitment to protect the container from excessive heat generated by the associated filling apparatus during filling.« less
Bracher, Susanne; Guérin, Kamila; Polyhach, Yevhen; Jeschke, Gunnar; Dittmer, Sophie; Frey, Sabine; Böhm, Maret; Jung, Heinrich
2016-03-04
The available structural information on LeuT and structurally related transporters suggests that external loop 4 (eL4) and the outer end of transmembrane domain (TM) 10' participate in the reversible occlusion of the outer pathway to the solute binding sites. Here, the functional significance of eL4 and the outer region of TM10' are explored using the sodium/proline symporter PutP as a model. Glu-311 at the tip of eL4, and various amino acids around the outer end of TM10' are identified as particularly crucial for function. Substitutions at these sites inhibit the transport cycle, and affect in part ligand binding. In addition, changes at selected sites induce a global structural alteration in the direction of an outward-open conformation. It is suggested that interactions between the tip of eL4 and the peptide backbone at the end of TM10' participate in coordinating conformational alterations underlying the alternating access mechanism of transport. Together with the structural information on LeuT-like transporters, the results further specify the idea that common design and functional principles are maintained across different transport families. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.
Bracher, Susanne; Guérin, Kamila; Polyhach, Yevhen; Jeschke, Gunnar; Dittmer, Sophie; Frey, Sabine; Böhm, Maret; Jung, Heinrich
2016-01-01
The available structural information on LeuT and structurally related transporters suggests that external loop 4 (eL4) and the outer end of transmembrane domain (TM) 10′ participate in the reversible occlusion of the outer pathway to the solute binding sites. Here, the functional significance of eL4 and the outer region of TM10′ are explored using the sodium/proline symporter PutP as a model. Glu-311 at the tip of eL4, and various amino acids around the outer end of TM10′ are identified as particularly crucial for function. Substitutions at these sites inhibit the transport cycle, and affect in part ligand binding. In addition, changes at selected sites induce a global structural alteration in the direction of an outward-open conformation. It is suggested that interactions between the tip of eL4 and the peptide backbone at the end of TM10′ participate in coordinating conformational alterations underlying the alternating access mechanism of transport. Together with the structural information on LeuT-like transporters, the results further specify the idea that common design and functional principles are maintained across different transport families. PMID:26728461
On the role of VDAC in apoptosis: fact and fiction.
Rostovtseva, Tatiana K; Tan, Wenzhi; Colombini, Marco
2005-06-01
Research on VDAC has accelerated as evidence grows of its importance in mitochondrial function and in apoptosis. New investigators entering the field are often confounded by the VDAC literature and its many apparent conflicts and contradictions. This review is an effort to shed light on the situation and identify reliable information from more questionable claims. Our views on the most important controversial issues are as follows: VDAC is only present in the mitochondrial outer membrane. VDAC functions as a monomer. VDAC functions normally with or without Ca(2+). It does not form channels that mediate the flux of proteins through membranes (peptides and unfolded proteins are excluded from this statement). Closure of VDAC, not VDAC opening, leads to mitochondria outer membrane permeabilization and apoptosis.
Electrochemical cells and methods of manufacturing the same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazzarella, Ricardo; Slocum, Alexander H.; Doherty, Tristan
2016-07-26
Electrochemical cells and methods of making electrochemical cells are described herein. In some embodiments, an apparatus includes a multi-layer sheet for encasing an electrode material for an electrochemical cell. The multi-layer sheet including an outer layer, an intermediate layer that includes a conductive substrate, and an inner layer disposed on a portion of the conductive substrate. The intermediate layer is disposed between the outer layer and the inner layer. The inner layer defines an opening through which a conductive region of the intermediate layer is exposed such that the electrode material can be electrically connected to the conductive region. Thus,more » the intermediate layer can serve as a current collector for the electrochemical cell.« less
Near wall turbulence: An experimental view
NASA Astrophysics Data System (ADS)
Stanislas, Michel
2017-10-01
The present paper draws upon the experience of the author to illustrate the potential of advanced optical metrology for understanding near-wall-turbulence physics. First the canonical flat plate boundary layer problem is addressed, initially very near to the wall and then in the outer region when the Reynolds number is high enough to generate an outer turbulence peak. The coherent structure organization is examined in detail with the help of stereoscopic particle image velocimetry (PIV). Then the case of a turbulent boundary layer subjected to a mild adverse pressure gradient is considered. The results obtained show the great potential of a joint experimental-numerical approach. The conclusion is that the insight provided by today's optical metrology opens the way for significant improvements in turbulence modeling in upcoming years.
Random Positions of Dendritic Spines in Human Cerebral Cortex
Morales, Juan; Benavides-Piccione, Ruth; Dar, Mor; Fernaud, Isabel; Rodríguez, Angel; Anton-Sanchez, Laura; Bielza, Concha; Larrañaga, Pedro; DeFelipe, Javier
2014-01-01
Dendritic spines establish most excitatory synapses in the brain and are located in Purkinje cell's dendrites along helical paths, perhaps maximizing the probability to contact different axons. To test whether spine helixes also occur in neocortex, we reconstructed >500 dendritic segments from adult human cortex obtained from autopsies. With Fourier analysis and spatial statistics, we analyzed spine position along apical and basal dendrites of layer 3 pyramidal neurons from frontal, temporal, and cingulate cortex. Although we occasionally detected helical positioning, for the great majority of dendrites we could not reject the null hypothesis of spatial randomness in spine locations, either in apical or basal dendrites, in neurons of different cortical areas or among spines of different volumes and lengths. We conclude that in adult human neocortex spine positions are mostly random. We discuss the relevance of these results for spine formation and plasticity and their functional impact for cortical circuits. PMID:25057209
Evaluation and management of 2 ferocactus spines in the orbit.
Russell, David J; Kim, Tim I; Kubis, Kenneth
2013-01-01
A 49-year-old woman, who had fallen face first in a cactus 1 week earlier, presented with a small, mobile, noninflamed subcutaneous nodule at the rim of her right lateral orbit with no other functional deficits. A CT scan was obtained, which revealed a 4-cm intraorbital tubular-shaped foreign body resembling a large cactus spine. A second preoperative CT scan, obtained for an intraoperative guidance system, demonstrated a second cactus spine, which was initially not seen on the first CT scan. Both spines were removed surgically without complication. The authors discuss factors that can cause diagnosis delay, review the radiographic features of cactus spines, and discuss the often times benign clinical course of retained cactus spine foreign bodies. To the authors' knowledge, this is the first case report of cactus spines in the orbit. Health-care professionals should have a low threshold for imaging in cases of traumatic injuries involving cactus spines.
Cervical Spine Injuries in the Athlete.
Schroeder, Gregory D; Vaccaro, Alexander R
2016-09-01
Cervical spine injuries are extremely common and range from relatively minor injuries, such as cervical muscle strains, to severe, life-threatening cervical fractures with spinal cord injuries. Although cervical spine injuries are most common in athletes who participate in contact and collision sports, such as American football and rugby, they also have been reported in athletes who participate in noncontact sports, such as baseball, gymnastics, and diving. Cervical spine injuries in athletes are not necessarily the result of substantial spine trauma; some athletes have chronic conditions, such as congenital stenosis, that increase their risk for a serious cervical spine injury after even minor trauma. Therefore, physicians who cover athletic events must have a thorough knowledge of cervical spine injures and the most appropriate ways in which they should be managed. Although cervical spine injuries can be career-ending injuries, athletes often are able to return to play after appropriate treatment if the potential for substantial re-injury is minimized.
3D morphology-based clustering and simulation of human pyramidal cell dendritic spines.
Luengo-Sanchez, Sergio; Fernaud-Espinosa, Isabel; Bielza, Concha; Benavides-Piccione, Ruth; Larrañaga, Pedro; DeFelipe, Javier
2018-06-13
The dendritic spines of pyramidal neurons are the targets of most excitatory synapses in the cerebral cortex. They have a wide variety of morphologies, and their morphology appears to be critical from the functional point of view. To further characterize dendritic spine geometry, we used in this paper over 7,000 individually 3D reconstructed dendritic spines from human cortical pyramidal neurons to group dendritic spines using model-based clustering. This approach uncovered six separate groups of human dendritic spines. To better understand the differences between these groups, the discriminative characteristics of each group were identified as a set of rules. Model-based clustering was also useful for simulating accurate 3D virtual representations of spines that matched the morphological definitions of each cluster. This mathematical approach could provide a useful tool for theoretical predictions on the functional features of human pyramidal neurons based on the morphology of dendritic spines.
Surrogate: A Body-Dexterous Mobile Manipulation Robot with a Tracked Base
NASA Technical Reports Server (NTRS)
Hebert, Paul (Inventor); Borders, James W. (Inventor); Hudson, Nicolas H. (Inventor); Kennedy, Brett A. (Inventor); Ma, Jeremy C. (Inventor); Bergh, Charles F. (Inventor)
2018-01-01
Robotics platforms in accordance with various embodiments of the invention can be utilized to implement highly dexterous robots capable of whole body motion. Robotics platforms in accordance with one embodiment of the invention include: a memory containing a whole body motion application; a spine, where the spine has seven degrees of freedom and comprises a spine actuator and three spine elbow joints that each include two spine joint actuators; at least one limb, where the at least one limb comprises a limb actuator and three limb elbow joints that each include two limb joint actuators; a tracked base; a connecting structure that connects the at least one limb to the spine; a second connecting structure that connects the spine to the tracked base; wherein the processor is configured by the whole body motion application to move the at least one limb and the spine to perform whole body motion.
Yang, Jian-Huan; Wang, Ying-Yong; Chan, Bosco Pui-Lok
2016-08-11
We describe a new species of the genus Leptobrachium from the Gaoligongshan Mountain Range, Yunnan Province of China based on molecular and morphological evidences. The new species, Leptobrachium tengchongense sp. nov., can be distinguished from its congeners by a combination of the following characters: (1) relatively small size (adult males SVL 41.7-51.5 mm); (2) head width slightly larger than head length; (3) tympanum indistinct; (4) two palmar tubercles oval and distinct, inner one larger than outer one; (5) sexually active males without spines on the upper lip; (6) dorsal skin smooth with distinct network of ridges; (7) dorsum pinkish grey and scattered with irregular black markings; (8) venter dark purplish-gray with numerous small white spots on tubercles, solid white chest; (9) iris bicolored, upper one-third light blue, lower two-third dark brown. With the description of the new species, the number of Leptobrachium species currently known from China adds up to ten.
Hulse-Smith, Lee; Illes, Mike
2007-01-01
In a previous study, mechanical engineering models were utilized to deduce impact velocity and droplet volume of circular bloodstains by measuring stain diameter and counting spines radiating from their outer edge. A blind trial study was subsequently undertaken to evaluate the accuracy of this technique, using an applied, crime scene methodology. Calculations from bloodstains produced on paper, drywall, and wood were used to derive surface-specific equations to predict 39 unknown mock crime scene bloodstains created over a range of impact velocities (2.2-5.7 m/sec) and droplet volumes (12-45 microL). Strong correlations were found between expected and observed results, with correlation coefficients ranging between 0.83 and 0.99. The 95% confidence limit associated with predictions of impact velocity and droplet volume was calculated for paper (0.28 m/sec, 1.7 microL), drywall (0.37 m/sec, 1.7 microL), and wood (0.65 m/sec, 5.2 microL).
A new species of Notodiaptomus from the Ecuadorian Andes (Copepoda, Calanoida, Diaptomidae).
Alonso, Miguel; Dos Santos-Silva, Edinaldo N; Jaume, Damià
2017-01-01
Notodiaptomus cannarensis sp. n. is described from a reservoir on the Amazonian slope of the Ecuadorian Andes. The new species is unique among diaptomid calanoid copepods in the display of hypertrophied, symmetrical wing-like extensions at each side of the female composite genital somite. Furthermore, it displays a female urosome reduced to only two somites due to the incorporation of abdominal somites III and IV to the composite genital double-somite, and a male right fifth leg with the outer spine of second exopodal segment recurved and implanted proximally on margin. It differs from any other Notodiaptomus in the display of a large rectangular lamella on proximal segment of exopod of male right fifth leg. The species is currently known only from Mazar reservoir, a eutrophic water body placed above 2127 m a.s.l. on the River Paute (Cañar Province; southern Ecuador), where it is the most common crustacean in the water column.
A new species of Notodiaptomus from the Ecuadorian Andes (Copepoda, Calanoida, Diaptomidae)
Alonso, Miguel; dos Santos-Silva, Edinaldo N.; Jaume, Damià
2017-01-01
Abstract Notodiaptomus cannarensis sp. n. is described from a reservoir on the Amazonian slope of the Ecuadorian Andes. The new species is unique among diaptomid calanoid copepods in the display of hypertrophied, symmetrical wing-like extensions at each side of the female composite genital somite. Furthermore, it displays a female urosome reduced to only two somites due to the incorporation of abdominal somites III and IV to the composite genital double-somite, and a male right fifth leg with the outer spine of second exopodal segment recurved and implanted proximally on margin. It differs from any other Notodiaptomus in the display of a large rectangular lamella on proximal segment of exopod of male right fifth leg. The species is currently known only from Mazar reservoir, a eutrophic water body placed above 2127 m a.s.l. on the River Paute (Cañar Province; southern Ecuador), where it is the most common crustacean in the water column. PMID:29134016
Routine handling methods affect behaviour of three-spined sticklebacks in a novel test of anxiety
Thompson, Ralph R.J.; Paul, Elizabeth S.; Radford, Andrew N.; Purser, Julia; Mendl, Michael
2016-01-01
Fish are increasingly popular subjects in behavioural and neurobiological research. It is therefore important that they are housed and handled appropriately to ensure good welfare and reliable scientific findings, and that species-appropriate behavioural tests (e.g. of cognitive/affective states) are developed. Routine handling of captive animals may cause physiological stress responses that lead to anxiety-like states (e.g. increased perception of danger). In fish, these may be particularly pronounced when handling during tank-to-tank transfer involves removal from water into air. Here we develop and use a new combined scototaxis (preference for dark over light areas) and novel-tank-diving test, alongside conventional open-field and novel-object tests, to measure the effects of transferring three-spined sticklebacks (Gasterosteus aculeatus) between tanks using a box or net (in and out of water respectively). Preference tests for dark over light areas confirmed the presence of scototaxis in this species. Open-field and novel-object tests failed to detect any significant differences between net and box-handled fish. However, the combined diving and scototaxis detected consistent differences between the treatments. Net-handled fish spent less time on the dark side of the tank, less time in the bottom third, and kept a greater distance from the ‘safe’ bottom dark area than box-handled fish. Possible explanations for this reduction in anxiety-like behaviour in net-handled fish are discussed. The combined diving and scototaxis test may be a sensitive and taxon-appropriate method for measuring anxiety-like states in fish. PMID:26965568
Lind, Emma E; Grahn, Mats
2011-05-01
Contamination can cause a rapid environmental change which may require populations to respond with evolutionary changes. To evaluate the effects of pulp mill effluents on population genetics, we sampled three-spined sticklebacks (Gasterosteus aculeatus) near four pulp mills and four adjacent reference sites and analyzed Amplified Fragment Length Polymorphism (AFLP) to compare genetic variability. A fine scale genetic structure was detected and samples from polluted sites separated from reference sites in multidimensional scaling plots (P<0.005, 1000 permutations) and locus-by-locus Analysis of Molecular Variance (AMOVA) further confirmed that habitats are significantly separated (F(ST)=0.021, P<0.01, 1023 permutations). The amount of genetic variation between populations did not differ between habitats, and populations from both habitats had similar levels of heterozygosity (polluted sites Nei's Hs=0.11, reference sites Nei's Hs=0.11). Still, pairwise F(ST): s between three, out of four, pairs of polluted-reference sites were significant. A F(ST)-outlier analysis showed that 21 (8.4%) loci were statistically different from a neutral distribution at the P<0.05 level and therefore indicated to be under divergent selection. When removing 13 F(ST)-outlier loci, significant at the P<0.01 level, differentiation between habitats disappeared in a multidimensional scaling plot. In conclusion, pulp mill effluence has acted as a selective agent on natural populations of G. aculeatus, causing a convergence in genotype composition change at multiple sites in an open environment. © The Author(s) 2011. This article is published with open access at Springerlink.com
Yataba, Ikuko; Otsuka, Noboru; Matsushita, Isao; Matsumoto, Hideo; Hoshino, Yuichi
2016-08-01
The newly developed S-flurbiprofen plaster (SFPP) is a tape-type patch that shows innovative percutaneous absorption. This study was designed to evaluate the safety of a long-term 52-week SFPP application to osteoarthritis (OA) patients. This was a multi-center, open-label, uncontrolled prospective study that included 201 OA patients. SFPP at 40 mg/day was applied to the site of pain in 101 patients and at 80 mg/day (2 patches) in 100 patients at a total of 301 sites for 52 weeks. The affected sites assessed included the knee (192), lumbar spine (66), cervical spine (26), and others (17). Drug safety was evaluated by medical examination, laboratory tests, and examination of vital signs. Efficacy was evaluated by the patient's and clinician's global assessments and clinical symptoms. Most patients (80.1 %) completed the 52-week SFPP application. The majority of drug-related adverse events (AEs) included mild dermatitis at the application sites and occurred in 46.8 % of the sites. No photosensitive dermatitis was observed. Systemic AEs occurred in 9.0 % of the patients; a serious AE (gastric ulcer hemorrhage) occurred in one patient. No clinically significant changes in the laboratory tests and vital signs were observed. The efficacy evaluation showed an improvement from 2 weeks after the SFPP application, which continued during the 52 weeks' treatment. No apparent safety concerns were observed, even during the long-term SFPP application. Therefore, SFPP could be an additional pharmacotherapy in OA treatment.
Glucocorticoids are critical regulators of dendritic spine development and plasticity in vivo
Liston, Conor; Gan, Wen-Biao
2011-01-01
Glucocorticoids are a family of hormones that coordinate diverse physiological processes in responding to stress. Prolonged glucocorticoid exposure over weeks has been linked to dendritic atrophy and spine loss in fixed tissue studies of adult brains, but it is unclear how glucocorticoids may affect the dynamic processes of dendritic spine formation and elimination in vivo. Furthermore, relatively few studies have examined the effects of stress and glucocorticoids on spines during the postnatal and adolescent period, which is characterized by rapid synaptogenesis followed by protracted synaptic pruning. To determine whether and to what extent glucocorticoids regulate dendritic spine development and plasticity, we used transcranial two-photon microscopy to track the formation and elimination of dendritic spines in vivo after treatment with glucocorticoids in developing and adult mice. Corticosterone, the principal murine glucocorticoid, had potent dose-dependent effects on dendritic spine dynamics, increasing spine turnover within several hours in the developing barrel cortex. The adult barrel cortex exhibited diminished baseline spine turnover rates, but these rates were also enhanced by corticosterone. Similar changes occurred in multiple cortical areas, suggesting a generalized effect. However, reducing endogenous glucocorticoid activity by dexamethasone suppression or corticosteroid receptor antagonists caused a substantial reduction in spine turnover rates, and the former was reversed by corticosterone replacement. Notably, we found that chronic glucocorticoid excess led to an abnormal loss of stable spines that were established early in life. Together, these findings establish a critical role for glucocorticoids in the development and maintenance of dendritic spines in the living cortex. PMID:21911374
Electrical Advantages of Dendritic Spines
Gulledge, Allan T.; Carnevale, Nicholas T.; Stuart, Greg J.
2012-01-01
Many neurons receive excitatory glutamatergic input almost exclusively onto dendritic spines. In the absence of spines, the amplitudes and kinetics of excitatory postsynaptic potentials (EPSPs) at the site of synaptic input are highly variable and depend on dendritic location. We hypothesized that dendritic spines standardize the local geometry at the site of synaptic input, thereby reducing location-dependent variability of local EPSP properties. We tested this hypothesis using computational models of simplified and morphologically realistic spiny neurons that allow direct comparison of EPSPs generated on spine heads with EPSPs generated on dendritic shafts at the same dendritic locations. In all morphologies tested, spines greatly reduced location-dependent variability of local EPSP amplitude and kinetics, while having minimal impact on EPSPs measured at the soma. Spine-dependent standardization of local EPSP properties persisted across a range of physiologically relevant spine neck resistances, and in models with variable neck resistances. By reducing the variability of local EPSPs, spines standardized synaptic activation of NMDA receptors and voltage-gated calcium channels. Furthermore, spines enhanced activation of NMDA receptors and facilitated the generation of NMDA spikes and axonal action potentials in response to synaptic input. Finally, we show that dynamic regulation of spine neck geometry can preserve local EPSP properties following plasticity-driven changes in synaptic strength, but is inefficient in modifying the amplitude of EPSPs in other cellular compartments. These observations suggest that one function of dendritic spines is to standardize local EPSP properties throughout the dendritic tree, thereby allowing neurons to use similar voltage-sensitive postsynaptic mechanisms at all dendritic locations. PMID:22532875
Utility of plain radiographs in detecting traumatic injuries of the cervical spine in children.
Nigrovic, Lise E; Rogers, Alexander J; Adelgais, Kathleen M; Olsen, Cody S; Leonard, Jeffrey R; Jaffe, David M; Leonard, Julie C
2012-05-01
The objective of this study was to estimate the sensitivity of plain radiographs in identifying bony or ligamentous cervical spine injury in children. We identified a retrospective cohort of children younger than 16 years with blunt trauma-related bony or ligamentous cervical spine injury evaluated between 2000 and 2004 at 1 of 17 hospitals participating in the Pediatric Emergency Care Applied Research Network. We excluded children who had a single or undocumented number of radiographic views or one of the following injuries types: isolated spinal cord injury, spinal cord injury without radiographic abnormalities, or atlantoaxial rotary subluxation. Using consensus methods, study investigators reviewed the radiology reports and assigned a classification (definite, possible, or no cervical spine injury) as well as film adequacy. A pediatric neurosurgeon, blinded to the classification of the radiology reports, reviewed complete case histories and assigned final cervical spine injury type. We identified 206 children who met inclusion criteria, of which 127 had definite and 41 had possible cervical spine injury identified by plain radiograph. Of the 186 children with adequate cervical spine radiographs, 168 had definite or possible cervical spine injury identified by plain radiograph for a sensitivity of 90% (95% confidence interval, 85%-94%). Cervical spine radiographs did not identify the following cervical spine injuries: fracture (15 children) and ligamentous injury alone (3 children). Nine children with normal cervical spine radiographs presented with 1 or more of the following: endotracheal intubation (4 children), altered mental status (5 children), or focal neurologic findings (5 children). Plain radiographs had a high sensitivity for cervical spine injury in our pediatric cohort.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-15
... (Thoracolumbar Spine) Conditions Disability Benefits Questionnaire) Under OMB Review AGENCY: Veterans Benefits... Control No. 2900- NEW (Back (Thoracolumbar Spine) Conditions Disability Benefits Questionnaire)'' in any... Disability Benefits Questionnaire)''. SUPPLEMENTARY INFORMATION: Title: (Back (Thoracolumbar Spine...
Raza, Mushahid; Elkhodair, Samer; Zaheer, Asif; Yousaf, Sohail
2013-11-01
A true gold standard to rule out a significant cervical spine injury in subset of blunt trauma patients with altered sensorium is still to be agreed upon. The objective of this study is to determine whether in obtunded adult patients with blunt trauma, a clinically significant injury to the cervical spine be ruled out on the basis of a normal multidetector cervical spine computed tomography. Comprehensive database search was conducted to include all the prospective and retrospective studies on blunt trauma patients with altered sensorium undergoing cervical spine multidetector CT scan as core imaging modality to "clear" the cervical spine. The studies used two main gold standards, magnetic resonance imaging of the cervical spine and/or prolonged clinical follow-up. The data was extracted to report true positive, true negatives, false positives and false negatives. Meta-analysis of sensitivity, specificity, negative and positive predictive values was performed using Meta Analyst Beta 3.13 software. We also performed a retrospective investigation comparing a robust clinical follow-up and/or cervical spine MR findings in 53 obtunded blunt trauma patients, who previously had undergone a normal multidetector CT scan of the cervical spine reported by a radiologist. A total of 10 studies involving 1850 obtunded blunt trauma patients with initial cervical spine CT scan reported as normal were included in the final meta-analysis. The cumulative negative predictive value and specificity of cervical spine CT of the ten studies was 99.7% (99.4-99.9%, 95% confidence interval). The positive predictive value and sensitivity was 93.7% (84.0-97.7%, 95% confidence interval). In the retrospective review of our obtunded blunt trauma patients, none was later diagnosed to have significant cervical spine injury that required a change in clinical management. In a blunt trauma patient with altered sensorium, a normal cervical spine CT scan is conclusive to safely rule out a clinically significant cervical spine injury. The results of this meta-analysis strongly support the removal of cervical precautions in obtunded blunt trauma patient after normal cervical spine computed tomography. Any further imaging like magnetic resonance imaging of the cervical spine should be performed on case-to-case basis. Copyright © 2013 Elsevier Ltd. All rights reserved.
Rose, Melanie K; Rosal, Lindy M; Gonzalez, Richard P; Rostas, Jack W; Baker, Jeremy A; Simmons, Jon D; Frotan, Mohammed A; Brevard, Sydney B
2012-08-01
The purpose of this study was to prospectively assess the sensitivity and efficacy of clinical examination for screening of cervical spine (c-spine) injury in awake and alert blunt trauma patients with concomitant "distracting injuries." During the 24-month period from December 2009 to December 2011, all blunt trauma patients older than 13 years were prospectively evaluated with a standard cervical spine examination protocol by the trauma surgery team at a Level 1 trauma center. Awake and alert patients with a Glasgow Coma Score (GCS) ≥14 underwent clinical examination of the cervical spine. Clinical examination was performed regardless of "distracting injuries." Patients without complaints of pain or tenderness on physical exam had their cervical collar removed, and the c-spine was considered clinically cleared of injury. All awake and alert patients with "distracting injuries," including those clinically cleared and those with complaints of c-spine pain or tenderness underwent computerized tomographic (CT) scanning of the entire c-spine. "Distracting injuries" were categorized into three anatomic regions: head injuries, torso injuries and long bone fractures. Patients with minor distracting injuries were not considered to have a "distracting injury." During the 24-month study period, 761 blunt trauma patients with GCS ≥14 and at least one "distracting injury" had been entered into the study protocol. Two-hundred ninety-six (39%) of the patients with "distracting injuries" had a positive c-spine clinical examination, 85 (29%) of whom were diagnosed with c-spine injury. Four hundred sixty-four (61%) of the patients with "distracting injuries"’ were initially clinically cleared, with one patient (0.2%) diagnosed with a c-spine injury. This yielded an overall sensitivity of 99% (85/86) and negative predictive value greater than 99% (463/464) for cervical spine clinical examination in awake and alert blunt trauma patients with "distracting injuries." In the awake and alert blunt trauma patient with "distracting injuries," clinical examination is a sensitive screening method for cervical spine injury. Radiological assessment is unnecessary for safe clearance of the asymptomatic cervical spine in awake and alert blunt trauma patients with "distracting injuries." These findings suggest the concept of "distracting injury" in the context of cervical spine clinical examination is invalid. Expanding the utility of cervical spine clinical examination to patients with "distracting injuries" allows for significant reduction of both healthcare cost and radiation exposure.
PLANETARY SYSTEM FORMATION IN THE PROTOPLANETARY DISK AROUND HL TAURI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akiyama, Eiji; Hasegawa, Yasuhiro; Hayashi, Masahiko
2016-02-20
We reprocess the Atacama Large Millimeter/Submillimeter Array (ALMA) long-baseline science verification data taken toward HL Tauri. Assuming the observed gaps are opened up by currently forming, unseen bodies, we estimate the mass of such hypothetical bodies based on the following two approaches: the Hill radius analysis and a more elaborate approach developed from the angular momentum transfer analysis in gas disks. For the former, the measured gap widths are used for estimating the mass of the bodies, while for the latter, the measured gap depths are utilized. We show that their masses are comparable to or less than the mass of Jovian planets.more » By evaluating Toomre’s gravitational instability (GI) condition and cooling effect, we find that the GI might be a mechanism to form the bodies in the outer region of the disk. As the disk might be gravitationally unstable only in the outer region of the disk, inward planetary migration would be needed to construct the current architecture of the observed disk. We estimate the gap-opening mass and show that type II migration might be able to play such a role. Combining GIs with inward migration, we conjecture that all of the observed gaps may be a consequence of bodies that might have originally formed at the outer part of the disk, and have subsequently migrated to the current locations. While ALMA’s unprecedented high spatial resolution observations can revolutionize our picture of planet formation, more dedicated observational and theoretical studies are needed to fully understand the HL Tauri images.« less
George, Joju; Soares, Cary; Montersino, Audrey; Beique, Jean-Claude; Thomas, Gareth M
2015-01-01
Precise regulation of the dendritic spine actin cytoskeleton is critical for neurodevelopment and neuronal plasticity, but how neurons spatially control actin dynamics is not well defined. Here, we identify direct palmitoylation of the actin regulator LIM kinase-1 (LIMK1) as a novel mechanism to control spine-specific actin dynamics. A conserved palmitoyl-motif is necessary and sufficient to target LIMK1 to spines and to anchor LIMK1 in spines. ShRNA knockdown/rescue experiments reveal that LIMK1 palmitoylation is essential for normal spine actin polymerization, for spine-specific structural plasticity and for long-term spine stability. Palmitoylation is critical for LIMK1 function because this modification not only controls LIMK1 targeting, but is also essential for LIMK1 activation by its membrane-localized upstream activator PAK. These novel roles for palmitoylation in the spatial control of actin dynamics and kinase signaling provide new insights into structural plasticity mechanisms and strengthen links between dendritic spine impairments and neuropathological conditions. DOI: http://dx.doi.org/10.7554/eLife.06327.001 PMID:25884247
Benavides-Piccione, Ruth; Fernaud-Espinosa, Isabel; Robles, Victor; Yuste, Rafael; DeFelipe, Javier
2013-01-01
Dendritic spines of pyramidal neurons are targets of most excitatory synapses in the cerebral cortex. Recent evidence suggests that the morphology of the dendritic spine could determine its synaptic strength and learning rules. However, unfortunately, there are scant data available regarding the detailed morphology of these structures for the human cerebral cortex. In the present study, we analyzed over 8900 individual dendritic spines that were completely 3D reconstructed along the length of apical and basal dendrites of layer III pyramidal neurons in the cingulate cortex of 2 male humans (aged 40 and 85 years old), using intracellular injections of Lucifer Yellow in fixed tissue. We assembled a large, quantitative database, which revealed a major reduction in spine densities in the aged case. Specifically, small and short spines of basal dendrites and long spines of apical dendrites were lost, regardless of the distance from the soma. Given the age difference between the cases, our results suggest selective alterations in spines with aging in humans and indicate that the spine volume and length are regulated by different biological mechanisms. PMID:22710613
Apparatus tube configuration and mounting for solid oxide fuel cells
Zymboly, Gregory E.
1993-01-01
A generator apparatus (10) is made containing long, hollow, tubular, fuel cells containing an inner air electrode (64), an outer fuel electrode (56), and solid electrolyte (54) therebetween, placed between a fuel distribution board (29) and a board (32) which separates the combustion chamber (16) from the generating chamber (14), where each fuel cell has an insertable open end and in insertable, plugged, closed end (44), the plugged end being inserted into the fuel distribution board (29) and the open end being inserted through the separator board (32) where the plug (60) is completely within the fuel distribution board (29).
COLUMBIA'S HATCH IS INSPECTED IN OPF BAY 1 AFTER STS-80 LANDING
NASA Technical Reports Server (NTRS)
1996-01-01
United Space Alliance (USA) technicians in Orbiter Processing Facility Bay 1 troubleshoot the orbiter Columbia's outer hatch of the airlock, which failed to open during the recent STS-80 Space Shuttle mission. Mission Specialists Tamara E. Jernigan and Thomas D. Jones did not perform the mission's planned two extravehicular activities (EVAs) or spacewalks because the hatch would not open on orbit. The spacewalks were to be part of the continuing series of EVA Development Flight Tests to evaluate equipment and procedures and to build spacewalking experience in preparation for the International Space Station.
Calculation of transmission probability by solving an eigenvalue problem
NASA Astrophysics Data System (ADS)
Bubin, Sergiy; Varga, Kálmán
2010-11-01
The electron transmission probability in nanodevices is calculated by solving an eigenvalue problem. The eigenvalues are the transmission probabilities and the number of nonzero eigenvalues is equal to the number of open quantum transmission eigenchannels. The number of open eigenchannels is typically a few dozen at most, thus the computational cost amounts to the calculation of a few outer eigenvalues of a complex Hermitian matrix (the transmission matrix). The method is implemented on a real space grid basis providing an alternative to localized atomic orbital based quantum transport calculations. Numerical examples are presented to illustrate the efficiency of the method.
Ota, Mitsutoshi; Furuya, Takeo; Maki, Satoshi; Inada, Taigo; Kamiya, Koshiro; Ijima, Yasushi; Saito, Junya; Takahashi, Kazuhisa; Yamazaki, Masashi; Aramomi, Masaaki; Mannoji, Chikato; Koda, Masao
2016-12-01
Laminoplasty (LMP) is a widely accepted surgical procedure for ossification of the posterior longitudinal ligament (OPLL) of the cervical spine. Progression of OPLL can occur in the long term after LMP. The aim of the present study was to determine whether addition of the instrumented fusion, (posterior decompression with instrumented fusion [PDF]), can suppress progression of OPLL or not. The present study included 50 patients who underwent LMP (n=23) or PDF (n=27) for OPLL of the cervical spine. We performed open door laminoplasty. PDF surgery was performed by double-door laminoplasty followed by instrumented fusion. We observed the non-ossified segment of the OPLL and measured the thickness of the OPLL at the thickest segment with pre- and postoperative sagittal CT multi-planar reconstruction images. Postoperative CT scan revealed fusion of the non-ossified segment of the OPLL was obtained in 4/23 patients (17%) in the LPM group and in 23/27 patients (85%) in the PDF group, showing a significant difference between both groups (p=0.003). Progression of the thickness of the OPLL in the PDF group (-0.1±0.4mm) was significantly smaller than in the LMP group (0.6±0.7mm, p=0.0002). The proportion of patients showing the decrease in thickness of OPLL was significantly larger in the PDF group (6/27 patients; 22%) than in the LMP group (0/23 patients; 0%, p=0.05). In conclusion, PDF surgery can suppress the thickening of OPLL. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Vehicle-assisted suicide with a nylon rope causing complete decapitation].
Blässer, Katharina; Tatschner, Thomas; Bohnert, Michael
2013-01-01
The present case deals with the unusual suicide method of a 36-year-old man who fastened one end of a nylon rope to a tree, guided the other end into a van through the open tailgate and placed the loop round his neck. Then he stepped on the accelerator. Before, he had marked the point on the ground where the rope would tighten. As the rope tightened complete decapitation occurred at a speed of about 35 km/h. Autopsy showed a nearly circular abrasion zone around the site of transection slightly ascending towards the nape, a fracture of the cervical spine between the 3rd and 4th vertebra and a fracture of the thoracic spine between the 7th and 8th vertebra. The test for air embolism of the heart was positive. Macroscopically, no evidence of blood aspiration was found. Histological investigation showed general anaemia and minor blood aspiration in the lungs. Wound morphology was largely in line with the injury patterns described after decapitation in the literature. However, our results differed in that blood aspiration was discernible only under the microscope and there was a second fracture of the spine. Decapitation as a suicide method is an expression of enormous autoaggression and is categorized as a "hard" suicide method. It is used predominantly by men and its occurrence in the spectrum of suicidal actions is rare. Police investigations revealed that the man had led a sort of double life with a sexually motivated background and had suffered from depressive episodes.
Volonterio, Odile
2010-12-01
Temnocephala brevicornis Monticelli, 1889 is the only species of the genus Temnocephala Blanchard, 1849 reported from chelonians to date. During a survey of the species of Temnocephala extant in southern Uruguay, two new species were found on the chelonian Hydromedusa tectifera Cope, 1869. They are described here as Temnocephala pereirai n. sp. and Temnocephala cuocoloi n. sp. Both resemble T. brevicornis, but differ in the morphometry of the penial stylet, and in qualitative details of the reproductive complex. Temnocephala pereirai n. sp. differs from T. brevicornis by having a massive, cylindrical sphincter in the distal portion of the vagina, and a seminal vesicle that opens into the subpolar to equatorial portion of the contractile vesicle. In addition, the penial stylet in Temnocephala pereirai n. sp. is large in relation to body size, straight and more slender, having the distal portion of its shaft slightly sinuous, and a smaller introvert equipped with about 16 distal crowns of smaller spines. Temnocephala cuocoloi n. sp. is most similar to T. brevicornis, but differs by having a smaller, curved penial stylet that has a smaller introvert in relation to stylet size, with about 10 distal crowns of smaller spines. A key to the species of the Temnocephala from chelonians is provided. This study supports the validity of the following characters previously proposed for the taxonomy of the genus Temnocephala: the shape of the sphincters in the female reproductive system, the shape of the penial stylet, and the number, size, and position of spines in the introvert.
Hyldmo, Per Kristian; Horodyski, MaryBeth; Conrad, Bryan P; Aslaksen, Sindre; Røislien, Jo; Prasarn, Mark; Rechtine, Glenn R; Søreide, Eldar
2017-11-01
Prehospital personnel who lack advanced airway management training must rely on basic techniques when transporting unconscious trauma patients. The supine position is associated with a loss of airway patency when compared to lateral recumbent positions. Thus, an inherent conflict exists between securing an open airway using the recovery position and maintaining spinal immobilization in the supine position. The lateral trauma position is a novel technique that aims to combine airway management with spinal precautions. The objective of this study was to compare the spinal motion allowed by the novel lateral trauma position and the well-established log-roll maneuver. Using a full-body cadaver model with an induced globally unstable cervical spine (C5-C6) lesion, we investigated the mean range of motion (ROM) produced at the site of the injury in six dimensions by performing the two maneuvers using an electromagnetic tracking device. Compared to the log-roll maneuver, the lateral trauma position caused similar mean ROM in five of the six dimensions. Only medial/lateral linear motion was significantly greater in the lateral trauma position (1.4mm (95% confidence interval [CI] 0.4, 2.4mm)). In this cadaver study, the novel lateral trauma position and the well-established log-roll maneuver resulted in comparable amounts of motion in an unstable cervical spine injury model. We suggest that the lateral trauma position may be considered for unconscious non-intubated trauma patients. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Delayed lymphocele formation following lateral lumbar interbody fusion of the spine.
Hey, Hwee Weng Dennis; Wong, Keng Lin; Gatam, Asrafi Rizki; Lim, Joel Louis; Wong, Hee-Kit
2017-05-01
This paper aims to describe the rare post-operative complication of a lymphocele formation after lateral lumbar interbody fusion. The patient in this case was a 76-year-old lady with a 10 year history of low back pain and neurogenic claudication. She had previously underwent multiple spine surgeries for her condition. She presented to our institution for a recurrence of her low back pain and right anterior thigh pain. She then underwent surgery in two stages; first, a mini-open lateral interbody fusion at L3/4 and L4/5; second, posterior instrumentation of T3 to S1 with sagittal spinal deformity correction. The patient recovered uneventfully in the initial post op period and was discharged within 8 days. However, she developed abdominal distension and discomfort 6 months after surgery. MRI and CT scan of her abdomen showed a retroperitoneal fluid collection compressing her left ureter, resulting in hydroureter and hydronephrosis. She was managed with a CT-guided drainage of the fluid collection. Fluid analysis was consistent with a lymphocele. Since the procedure, the patient has been asymptomatic for 2 years. Delayed lymphocele formation is a potential complication of lateral lumbar interbody fusion. When present, it can be managed conservatively with good results. This case suggests that surgeons should have a low threshold to investigate for a lymphocele development post-anterior or lateral lumbar spine surgery. The authors recommend the placement of a post surgical retroperitoneal drain, as it might assist in the early detection of a lymphocele formation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-17
... (Cervical Spine) Conditions Disability Benefits Questionnaire) Activity: Comment Request AGENCY: Veterans... ``OMB Control No. 2900--NEW (Neck (Cervical Spine) Conditions Disability Benefits Questionnaire)'' in... (Cervical Spine) Conditions Disability Benefits Questionnaire) Disability Benefits Questionnaire, VA Form 21...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-31
... (Cervical Spine) Conditions Disability Benefits Questionnaire) Activity Under OMB Review AGENCY: Veterans... Control No. 2900-- NEW (Neck (Cervical Spine) Conditions Disability Benefits Questionnaire)'' in any...) Conditions Disability Benefits Questionnaire).'' SUPPLEMENTARY INFORMATION: Title: (Neck (Cervical Spine...
Neely, M. Diana; Schmidt, Dennis E.; Deutch, Ariel Y.
2007-01-01
The proximate cause of Parkinson’s Disease is striatal dopamine depletion. Although no overt toxicity to striatal neurons has been reported in Parkinson’s Disease, one of the consequences of striatal dopamine loss is a decrease in the number of dendritic spines on striatal medium spiny neurons (MSNs). Dendrites of these neurons receive cortical glutamatergic inputs onto the dendritic spine head and dopaminergic inputs from the substantia nigra onto the spine neck. This synaptic arrangement suggests that dopamine gates corticostriatal glutamatergic drive onto spines. Using triple organotypic slice cultures comprised of ventral mesencephalon, striatum, and cortex, we examined the role of the cortex in dopamine depletion-induced dendritic spine loss in MSNs. The striatal dopamine innervation was lesioned by treatment of the cultures with the dopaminergic neurotoxin MPP+ or by removing the mesencephalon. Both MPP+ and mesencephalic ablation decreased MSN dendritic spine density. Analysis of spine morphology revealed that thin spines were preferentially lost after dopamine depletion. Removal of the cortex completely prevented dopamine depletion-induced spine loss. These data indicate that the dendritic remodeling of MSNs seen in parkinsonism occurs secondary to increases in corticostriatal glutamatergic drive, and suggest that modulation of cortical activity may be a useful therapeutic strategy in Parkinson’s Disease. PMID:17888581
Lauterborn, Julie C.; Jafari, Matiar; Babayan, Alex H.; Gall, Christine M.
2015-01-01
Fragile X Syndrome (FXS) and the Fmr1 knockout (KO) mouse model of this disorder exhibit abnormal dendritic spines in neocortex, but the degree of spine disturbances in hippocampus is not clear. The present studies tested if the mutation influences dendritic branching and spine measures for CA1 pyramidal cells in Fmr1 KO and wild-type (WT) mice provided standard or enriched environment (EE) housing. Automated measures from 3D reconstructions of green fluorescent protein (GFP)-labeled cells showed that spine head volumes were ∼40% lower in KOs when compared with WTs in both housing conditions. With standard housing, average spine length was greater in KOs versus WTs but there was no genotype difference in dendritic branching, numbers of spines, or spine length distribution. However, with EE rearing, significant effects of genotype emerged including greater dendritic branching in WTs, greater spine density in KOs, and greater numbers of short thin spines in KOs when compared with WTs. Thus, EE rearing revealed greater effects of the Fmr1 mutation on hippocampal pyramidal cell morphology than was evident with standard housing, suggesting that environmental enrichment allows for fuller appreciation of the impact of the mutation and better representation of abnormalities likely to be present in human FXS. PMID:24046080
Oshima, Toru; Hayashida, Mitsumasa; Ohtani, Maki; Hashimoto, Manabu; Takahashi, Satoshi; Ishiyama, Koichi; Otani, Takahiro; Koga, Makoto; Sugawara, Makoto; Mimasaka, Sohtaro
2014-07-01
Although spine injuries are not always detectable on postmortem computed tomography (PMCT), spinal hyperostosis, an important risk factor for spine injury, is relatively easily detectable on PMCT. We therefore examined the utility of the detection of spinal hyperostosis on PMCT as an indicator of spine injury. Full-body PMCT images of 88 autopsy cases with a bruise on the face or forehead but no identifiable skull fracture were reviewed prior to autopsy for the identification and classification of spinal hyperostosis. Spine injuries were observed in 56.0% of cases with spinal hyperostosis and 1.6% of cases without spinal hyperostosis. Among the cases with spinal hyperostosis, spine injuries were observed in 66.7% of cases at stage 2 or 3 and in 88.9% of cases at stage 3. Spine injuries were diagnosed on PMCT in 33.3% of cases prior to autopsy. A significant association was found between spinal hyperostosis and presence of spine injury that cannot be detected on PMCT, indicating that the identification of spinal hyperostosis on PMCT may assist in detecting spine injuries. This finding suggests that investigation of the presence of spine injury based on the identification of spinal hyperostosis on PMCT may assist in determining the correct cause of death by autopsy. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Hernández-Orts, Jesús S; Timi, Juan T; Raga, Juan A; García-Varela, M; Crespo, Enrique A; Aznar, Francisco J
2012-06-01
Acanthocephalans have evolved a hooked proboscis and some taxa have trunk spines to attach to their definitive hosts. These structures are generated before being used, thus a key question is how investment in attachment could optimally be allocated through the ontogeny. The number and arrangement of hooks and spines are never modified in the definitive host, but it is unclear whether these structures grow during adult development. A comparison of the size of trunk spines between cystacanths and adults of Corynosoma cetaceum and C. australe indicated that spines grow in both species, but only in females, which also had significantly larger spines than males. This sexual dimorphism did not result from pure allometry because the body of females was smaller, and did not grow more than that of males. However, having a longer lifespan, females would need to withstand the extreme flow conditions prevailing in marine mammals for longer, inducing different investment and development schedules for spines. Patterns of spine growth also differed between species: fore-trunk spines grew in both species, but hind-trunk spines did only in C. cetaceum. In conclusion, investment strategies on attachment may differ, not only between congeneric species of acanthocephalan, but also between sexes of the same species.
Herriott, Trystan M.; Sherrod, David R.; Pallister, John S.; Vallance, James W.; Sherrod, David R.; Scott, William E.; Stauffer, Peter H.
2008-01-01
The 2004-5 eruption of Mount St. Helens, still ongoing as of this writing (September 2006), has comprised chiefly lava dome extrusion that produced a series of solid, faultgouge-mantled dacite spines. Vertical aerial photographs taken every 2 to 4 weeks, visual observations, and oblique photographs taken from aircraft and nearby observation points provide the basis for two types of photogeologic maps of the dome--photo-based maps and rectified maps. Eight map pairs, covering the period from October 1, 2004, through December 15, 2005, document the development of seven spines: an initial small, fin-shaped vertical spine; a north-south elongate wall of dacite; two large and elongate recumbent spines (“whalebacks”); a tall and elongate inclined spine; a smaller bulbous spine; and an initially endogenous spine extruded between remnants of preceding spines. All spines rose from the same general vent area near the southern margin of the 1980s lava dome. Maps also depict translation and rotation of active and abandoned spines, progressive deformation affecting Crater Glacier, and distribution of ash on the crater floor from phreatic and phreatomagmatic explosions. The maps help track key geologic and geographic features in the rapidly changing crater and help date dome, gouge, and ash samples that are no longer readily correlated to their original context because of deformation in a dynamic environment where spines extrude, deform, slough, and are overrun by newly erupted material.
Clark, Taylor A; Fu, Min; Dunn, Andrew K; Zuo, Yi; Jones, Theresa A
2018-07-01
Previous findings that skill learning is associated with the formation and preferential stabilization of new dendritic spines in cortex have raised the possibility that this preferential stabilization is a mechanism for lasting skill memory. We investigated this possibility in adult mice using in vivo two-photon imaging to monitor spine dynamics on superficial apical dendrites of layer V pyramidal neurons in motor cortex during manual skill learning. Spine formation increased over the first 3 days of training on a skilled reaching task, followed by increased spine elimination. A greater proportion of spines formed during the first 3 training days were lost if training stopped after 3, compared with 15 days. However, performance gains achieved in 3 training days persisted, indicating that preferential new spine stabilization was non-essential for skill retention. Consistent with a role in ongoing skill refinement, the persistence of spines formed early in training strongly predicted performance improvements. Finally, while we observed no net spine density change on superficial dendrites, the density of spines on deeper apical branches of the same neuronal population was increased regardless of training duration, suggestive of a potential role in the retention of the initial skill memory. Together, these results indicate dendritic subpopulation-dependent variation in spine structural responses to skill learning, which potentially reflect distinct contributions to the refinement and retention of newly acquired motor skills. Copyright © 2018 Elsevier Inc. All rights reserved.
Visualization of scoliotic spine using ultrasound-accessible skeletal landmarks
NASA Astrophysics Data System (ADS)
Church, Ben; Lasso, Andras; Schlenger, Christopher; Borschneck, Daniel P.; Mousavi, Parvin; Fichtinger, Gabor; Ungi, Tamas
2017-03-01
PURPOSE: Ultrasound imaging is an attractive alternative to X-ray for scoliosis diagnosis and monitoring due to its safety and inexpensiveness. The transverse processes as skeletal landmarks are accessible by means of ultrasound and are sufficient for quantifying scoliosis, but do not provide an informative visualization of the spine. METHODS: We created a method for visualization of the scoliotic spine using a 3D transform field, resulting from thin-spline interpolation of a landmark-based registration between the transverse processes that we localized in both the patient's ultrasound and an average healthy spine model. Additional anchor points were computationally generated to control the thin-spline interpolation, in order to gain a transform field that accurately represents the deformation of the patient's spine. The transform field is applied to the average spine model, resulting in a 3D surface model depicting the patient's spine. We applied ground truth CT from pediatric scoliosis patients in which we reconstructed the bone surface and localized the transverse processes. We warped the average spine model and analyzed the match between the patient's bone surface and the warped spine. RESULTS: Visual inspection revealed accurate rendering of the scoliotic spine. Notable misalignments occurred mainly in the anterior-posterior direction, and at the first and last vertebrae, which is immaterial for scoliosis quantification. The average Hausdorff distance computed for 4 patients was 2.6 mm. CONCLUSIONS: We achieved qualitatively accurate and intuitive visualization to depict the 3D deformation of the patient's spine when compared to ground truth CT.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-17
... (Thoracolumbar Spine) Conditions Disability Benefits Questionnaire) Activity: Comment Request AGENCY: Veterans...--NEW (Collection (Back (Thoracolumbar Spine) Conditions Disability Benefits Questionnaire)'' in any... (Thoracolumbar Spine) Conditions Disability Benefits Questionnaire, VA Form 21-0960M-14. OMB Control Number: 2900...
Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... The test is done in a hospital radiology department or in the health care provider's office. You will lie on the x-ray table in different positions. If the x-ray ...
Hansberry, D R; Donovan, A L; Prabhu, A V; Agarwal, N; Cox, M; Flanders, A E
2017-06-01
More than 75 million Americans have less than adequate health literacy skills according to the National Center for Education Statistics. Readability scores are used as a measure of how well populations read and understand patient education materials. The purpose of this study was to assess the readability of Web sites dedicated to patient education for radiologic spine imaging and interventions. Eleven search terms relevant to radiologic spine imaging were searched on the public Internet, and the top 10 links for each term were collected and analyzed to determine readability scores by using 10 well-validated quantitative readability assessments from patient-centered education Web sites. The search terms included the following: x-ray spine, CT spine, MR imaging spine, lumbar puncture, kyphoplasty, vertebroplasty, discogram, myelogram, cervical spine, thoracic spine, and lumbar spine. Collectively, the 110 articles were written at an 11.3 grade level (grade range, 7.1-16.9). None of the articles were written at the American Medical Association and National Institutes of Health recommended 3rd-to-7th grade reading levels. The vertebroplasty articles were written at a statistically significant ( P < .05) more advanced level than the articles for x-ray spine, CT spine, and MR imaging spine. Increasing use of the Internet to obtain health information has made it imperative that on-line patient education be written for easy comprehension by the average American. However, given the discordance between readability scores of the articles and the American Medical Association and National Institutes of Health recommended guidelines, it is likely that many patients do not fully benefit from these resources. © 2017 by American Journal of Neuroradiology.
Shum, Gary L K; Crosbie, Jack; Lee, Raymond Y W
2005-09-01
Experimental study to describe lumbar spine and hip joint movements during sit-to-stand and stand-to-sit. To examine differences in the kinematics and joint coordination of the lumbar spine and hips during sit-to-stand and stand-to-sit between healthy subjects and patients with subacute low back pain (LBP). There is a paucity of information on the coordination of movements of lumbar spine and hips during sit-to-stand and stand-to-sit. The effect of LBP, with or without nerve root signs, is largely unknown. A three-dimensional real-time electromagnetic tracking device was used to measure movements of the lumbar spine and hips during sit-to-stand and stand-to-sit. Sixty subacute LBP participants with or without straight leg raise signs and 20 healthy asymptomatic participants were recruited. The kinematic patterns of lumbar spine and hips were analyzed. Coordination between the two joints was studied by relative phase angle analysis. The mobility of the spine and hips was significantly limited in back pain subjects. It was observed that LBP subjects employed various strategies to compensate for the limited motions at the hips and lumbar spine. The contribution of the lumbar spine relative to that of the hip was found to be reduced for subjects with LBP. The lumbar spine-hip joint coordination was significantly altered in back pain subjects, in particular, those with positive straight leg raise sign. Back pain was related to changes in the kinematics and coordination of the lumbar spine and hips during sit-to-stand and stand-to-sit. Assessment of back pain patients should include kinematic analysis of the hips as well as the spine.
Cervical Spine Injuries in Children Associated With Sports and Recreational Activities.
Babcock, Lynn; Olsen, Cody S; Jaffe, David M; Leonard, Julie C
2016-09-30
The aim of this study was to ascertain potential factors associated with cervical spine injuries in children injured during sports and recreational activities. This is a secondary analysis of a multicenter retrospective case-control study involving children younger than 16 years who presented to emergency departments after blunt trauma and underwent cervical spine radiography. Cases had cervical spine injury from sports or recreational activities (n = 179). Comparison groups sustained (1) cervical spine injury from other mechanisms (n = 361) or (2) other injuries from sports and recreational activities but were free of cervical spine injury (n = 180). For children with sport and recreational activity-related cervical spine injuries, common injury patterns were subaxial (49%) and fractures (56%). These children were at increased odds of spinal cord injury without radiographic abnormalities compared with children with cervical spine injuries from other mechanisms (25% vs 6%). Children with sport and recreational activity-related trauma had increased odds of cervical spine injury if they had focal neurologic findings (odds ratio [OR], 5.7; 95% confidence interval [CI], 3.5-9.4), had complaints of neck pain (OR, 3.1; 95% CI, 1.9-5.0), were injured diving (OR, 43.5; 95% CI, 5.9-321.3), or sustained axial loading impacts (OR, 2.2; 95% CI, 1.3-3.5). Football (22%), diving (20%), and bicycle crashes (11%) were the leading activities associated with cervical spine injury. In children injured during sports and recreational activities, focal neurologic findings, neck pain, axial loading impacts, and the possibility of spinal cord injury without radiographic abnormality should guide the diagnostic evaluation for potential cervical spine injuries. Certain activities have a considerable frequency of cervical spine injury, which may benefit from activity-specific preventive measures.
Yield of computed tomography of the cervical spine in cases of simple assault.
Uriell, Matthew L; Allen, Jason W; Lovasik, Brendan P; Benayoun, Marc D; Spandorfer, Robert M; Holder, Chad A
2017-01-01
Computed tomography (CT) of the cervical spine (C-spine) is routinely ordered for low-impact, non-penetrating or "simple" assault at our institution and others. Common clinical decision tools for C-spine imaging in the setting of trauma include the National Emergency X-Radiography Utilization Study (NEXUS) and the Canadian Cervical Spine Rule for Radiography (CCR). While NEXUS and CCR have served to decrease the amount of unnecessary imaging of the C-spine, overutilization of CT is still of concern. A retrospective, cross-sectional study was performed of the electronic medical record (EMR) database at an urban, Level I Trauma Center over a 6-month period for patients receiving a C-spine CT. The primary outcome of interest was prevalence of cervical spine fracture. Secondary outcomes of interest included appropriateness of C-spine imaging after retrospective application of NEXUS and CCR. The hypothesis was that fracture rates within this patient population would be extremely low. No C-spine fractures were identified in the 460 patients who met inclusion criteria. Approximately 29% of patients did not warrant imaging by CCR, and 25% by NEXUS. Of note, approximately 44% of patients were indeterminate for whether imaging was warranted by CCR, with the most common reason being lack of assessment for active neck rotation. Cervical spine CT is overutilized in the setting of simple assault, despite established clinical decision rules. With no fractures identified regardless of other factors, the likelihood that a CT of the cervical spine will identify clinically significant findings in the setting of "simple" assault is extremely low, approaching zero. At minimum, adherence to CCR and NEXUS within this patient population would serve to reduce both imaging costs and population radiation dose exposure. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Frinchaboy, Peter Michael, III
Establishing the rotation curve of the Milky Way is one of the fundamental contributions needed to understand the Galaxy and its mass distribution. We have undertaken a systematic spectroscopic survey of open star clusters which can serve as tracers of Galactic disk dynamics. We report on our initial sample of 67 clusters for which the Hydra multi-fiber spectrographs on the WIYN and Blanco telescopes have delivered ~1-2 km s -1 radial velocities (RVs) of many dozens of stars in the fields of each cluster, which are used to derive cluster membership and bulk cluster kinematics when combined with Tycho-2 proper motions. The clusters selected for study have a broad spatial distribution in order to be sensitive to the disk velocity field in all Galactic quadrants and across a Galactocentric radius range as much as 3.0 kpc from the solar circle. Through analysis of the cluster sample, we find (1) the rotation velocity of the Local Standard of Rest (LSR) is [Special characters omitted.] km s -1 , (2 ) the local rotation curve is declining with radius having a slope of -9.1 km s -1 kpc -1 , (3) we find (using R 0 = 8.5 kpc) the following Galactic parameters: A = 17.0 km s -1 kpc -1 and B = -8.9 km s -1 kpc -1 , which using a flat rotation curve and our determined values for the rotation velocity of the LSR yields a Galaxy mass within 1.5 R 0 of M = 1.4 ± 0.2 × 10 11 [Spe cial characters omitted.] and a M/L of 9 [Special characters omitted.] . We also explore the distribution of the local velocity field and find evidence for non- circular motion due to the spiral arms. Additionally, a number of outer disk ( R gc > 12 kpc) open clusters, including Be29 and Sa1, are studied that have potentially critical leverage on radial, age and metallicity gradients in the outer Galactic disk. We find that the measured kinematics of Sa1 and Be29 are consistent with being associated with the Galactic anticenter stellar structure (GASS; or Monoceros stream), which points to a possible "accretion" origin for these and possibly other outer disk open clusters, if one believes that GASS represents an accreting dwarf galaxy system.
Vascularization and odontode structure of a dorsal ridge spine of Romundina stellina Ørvig 1975
Qu, Qingming; Sanchez, Sophie; Ahlberg, Per Erik; Haitina, Tatjana
2017-01-01
There are two types of dermal skeletons in jawed vertebrates: placoderms and osteichthyans carry large bony plates (macromery), whereas chondrichthyans and acanthodians are covered by small scales (micromery). Fin spines are one of the last large dermal structures found on micromeric taxa and offer a potential source of histology and morphology that can be compared to those found on macromeric groups. Dermal fin spines offer a variety of morphology but aspects of their growth modes and homology are unclear. Here, we provide detailed descriptions of the microstructure and growth of a dorsal ridge spine from the acanthothoracid placoderm, Romundina stellina, using virtual three-dimensional paleohistological datasets. From these data we identify several layers of dentine ornamentation covering the lateral surfaces of the spine and reconstructed their growth pattern. We show that this spine likely grew posteriorly and proximally from a narrow portion of bone located along the leading edge of the spine. The spine is similarly constructed to the scales with a few exceptions, including the absence of polarized fibers distributed throughout the bone and the presence of a thin layer of perichondral bone. The composition of the spine (semidentine odontodes, dermal bone, perichondral bone) is identical to that of the Romundina dermal plates. These results illustrate the similarities and differences between the dermal tissues in Romundina and indicate that the spine grew differently from the dentinous fin spines from extant and fossil chondrichthyans. The morphology and histology of Romundina is most similar to the fin spine of the probable stem osteichthyan Lophosteus, with a well-developed inner cellular bony base and star-shaped odontodes on the surface. Results from these studies will undoubtedly have impact on our understanding of fossil fin spine histology and evolution, contributing to the on-going revision of early gnathostome phylogeny. PMID:29281687
A simulation study of spine biofidelity in the hybrid-III 6-year-old ATD.
Wu, Jun; Cao, Libo; Reed, Matthew P; Hu, Jingwen
2013-01-01
Because of the lack of pediatric biomechanical data, Hybrid-III (HIII) child anthropomorphic test devices (ATDs) are essentially scaled from the mid-size male ATD based on the geometric considerations. These ATDs inherit a rigid thoracic spine from the adult HIII ATDs, which has been criticized as unrealistic. Therefore, the objective of this study was to explore possible design modifications for improving the spine biofidelity of the HIII 6-year-old ATD. A previously developed and validated HIII 6-year-old MADYMO ATD model was used as the baseline model to investigate the effects of design modifications on the spine biofidelity of the current ATD. Several sets of child volunteer and cadaver test data were considered as the design targets, including child volunteer low-speed crash test data, pediatric cadaver cervical spine tensile test data, and child cadaver crash test data. ATD design modifications include adding an additional joint to the thoracic spine region and changing the joint characteristics at the cervical and lumbar spine regions. Optimization techniques were used to match simulation results to each set of test results. The results indicate that the translational characteristics of the cervical and lumbar spine in the current child ATD need to be reduced to achieve realistic spine flexibility. Adding an additional joint at the thoracic spine region with degree of freedom in both flexion/extension and tension would significantly improve the ATD biofidelity in terms of predicting the overall spine curvature and head excursion in frontal crashes. Future ATD spine modification should focus on reducing the neck and lumbar tension stiffness and adding additional flexibility both in flexion/extension and tension at the thoracic spine region. The child ATD model developed in this study can be used as an important tool to improve child ATD biofidelity and child restraint system design in motor vehicle crashes.
Ammendolia, Carlo; Côté, Pierre; Hogg-Johnson, Sheilah; Bombardier, Claire
2009-07-01
In Ontario, chiropractors see one-third of patients who seek care for low back pain. Previous studies suggest that chiropractors have high utilization rates of lumbar and full spine radiography. There has been a proliferation of evidence-based guidelines recommending that plain film radiography be used only to assess high-risk patients with low back pain. Evidence for the use of full spine radiography, except for the evaluation of scoliosis is lacking. It is uncertain what impact the growing evidence against their use has had on radiography utilization by Ontario chiropractors. To describe the annual costs and use of lumbar and full spine plain film radiography among Ontario chiropractors between 1994 and 2001. Time-trend analysis of radiography utilization by Ontario chiropractors. Chiropractic claims data submitted to the Ontario Health Insurance Plan or the Workplace Safety & Insurance Board from 1994/1995 to 2000/2001. Change in the annual cost and proportion of claimants receiving lumbar and full spine radiography. Time-trend analysis of chiropractic claims submitted to the Ontario Health Insurance Plan (OHIP) or Workplace Safety & Insurance Board (WSIB) from 1994/1995 to 2000/2001 fiscal years. During the 7-year period, the proportion of OHIP claimants receiving lumbar spine radiography decreased from 4.54% to 3.25% and for full spine radiography from 3.87% to 3.04%. For WSIB claimants, lumbar spine radiography deceased from 6.49% to 3.30% of claimants and full spine radiography from 1.51% to 0.94%. OHIP payments for lumbar spine radiography decreased 12.7% to $562,944, whereas full spine radiography payments decreased 5.3% to $1,071,408. WSIB lumbar and full spine radiography payments decreased 44.2% and 34.3% to $31,202 and $11,713 respectively. Claims data from the two largest third-party payers of chiropractic services in Ontario, suggest that lumbar and full spine radiography, and their associated costs decreased steadily between 1994 and 2001.
Gsell, Kelsey Y; Zwambag, Derek P; Fournier, Dale E; Séguin, Cheryle A; Brown, Stephen H M
2017-10-01
Basic science study of the relationship between the structural properties of the spine and its surrounding musculature. To determine whether an increase in spine stiffness causes an inverse compensatory change in the passive stiffness of the adjacent paraspinal muscles. Intervertebral disc degeneration causes an increase in multifidus passive stiffness; this was hypothesized to compensate for a decrease in spine stiffness associated with disc degeneration. Mice lacking equilibrative nucleoside transporter 1 (ENT1) develop progressive ectopic calcification of the fibrous connective tissues of the spine, which affects the lumbar spine by 6 months of age and likely creates a mechanically stiffer spine. Experiments were conducted on four groups of mice (n = 8 mice/group): wild-type (WT) and ENT1 knockout (KO) at 2 or 8 months of age. Lumbar spines were removed and tested in cyclic axial compression to determine neutral zone length and stiffness. Single muscle fibers and bundles of fibers were isolated from lumbar multifidus and erector spinae, as well as tibialis anterior (a non-spine-related control) and tested to determine elastic modulus (passive stiffness). At 2 months of age, neither spine nor muscle stiffness was different between KO and WT. At 8 months of age, compared with WT the lumbar spines of ENT1 KO mice had a stiffer and shorter neutral zone, and the paraspinal muscle fibers were less stiff; however, fiber bundles were not different. In addition, tibialis anterior was not different between KO and WT. This work has confirmed that calcification of spinal connective tissues in the ENT1 KO mouse results in a stiffened spine, whereas the concurrent decrease in muscle fiber elastic modulus in the adjacent paraspinal muscles suggests a direct compensatory relationship between the stiffness of the spine and the muscles that are attached to it. N/A.
Cidaroids spines facing ocean acidification.
Dery, Aurélie; Tran, Phuong Dat; Compère, Philippe; Dubois, Philippe
2018-07-01
When facing seawater undersaturated towards calcium carbonates, spines of classical sea urchins (euechinoids) show traces of corrosion although they are covered by an epidermis. Cidaroids (a sister clade of euechinoids) are provided with mature spines devoid of epidermis, which makes them, at first sight, more sensitive to dissolution when facing undersaturated seawater. A recent study showed that spines of a tropical cidaroid are resistant to dissolution due to the high density and the low magnesium concentration of the peculiar external spine layer, the cortex. The biofilm and epibionts covering the spines was also suggested to take part in the spine protection. Here, we investigate the protective role of these factors in different cidaroid species from a broad range of latitude, temperature and depth. The high density of the cortical layer and the cover of biofilm and epibionts were confirmed as key protection against dissolution. The low magnesium concentration of cidaroid spines compared to that of euechinoid ones makes them less soluble in general. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jayant, Krishna; Hirtz, Jan J.; Plante, Ilan Jen-La; Tsai, David M.; de Boer, Wieteke D. A. M.; Semonche, Alexa; Peterka, Darcy S.; Owen, Jonathan S.; Sahin, Ozgur; Shepard, Kenneth L.; Yuste, Rafael
2017-05-01
Dendritic spines are the primary site of excitatory synaptic input onto neurons, and are biochemically isolated from the parent dendritic shaft by their thin neck. However, due to the lack of direct electrical recordings from spines, the influence that the neck resistance has on synaptic transmission, and the extent to which spines compartmentalize voltage, specifically excitatory postsynaptic potentials, albeit critical, remains controversial. Here, we use quantum-dot-coated nanopipette electrodes (tip diameters ∼15-30 nm) to establish the first intracellular recordings from targeted spine heads under two-photon visualization. Using simultaneous somato-spine electrical recordings, we find that back propagating action potentials fully invade spines, that excitatory postsynaptic potentials are large in the spine head (mean 26 mV) but are strongly attenuated at the soma (0.5-1 mV) and that the estimated neck resistance (mean 420 MΩ) is large enough to generate significant voltage compartmentalization. Nanopipettes can thus be used to electrically probe biological nanostructures.
Jayant, Krishna; Hirtz, Jan J.; Plante, Ilan Jen-La; Tsai, David M.; De Boer, Wieteke D. A. M.; Semonche, Alexa; Peterka, Darcy S.; Owen, Jonathan S.; Sahin, Ozgur; Shepard, Kenneth L.; Yuste, Rafael
2017-01-01
Dendritic spines are the primary site of excitatory synaptic input onto neurons, and are biochemically isolated from the parent dendritic shaft by their thin neck. However, due to the lack of direct electrical recordings from spines, the influence that the neck resistance has on synaptic transmission, and the extent to which spines compartmentalize voltage, specifically excitatory postsynaptic potentials, albeit critical, remains controversial. Here, we use quantum-dot-coated nanopipette electrodes (tip diameters ~15–30 nm) to establish the first intracellular recordings from targeted spine heads under two-photon visualization. Using simultaneous somato-spine electrical recordings, we find that back propagating action potentials fully invade spines, that excitatory postsynaptic potentials are large in the spine head (mean 26 mV) but are strongly attenuated at the soma (0.5–1 mV) and that the estimated neck resistance (mean 420 MΩ) is large enough to generate significant voltage compartmentalization. Nanopipettes can thus be used to electrically probe biological nanostructures. PMID:27941898
Jayant, Krishna; Hirtz, Jan J; Plante, Ilan Jen-La; Tsai, David M; De Boer, Wieteke D A M; Semonche, Alexa; Peterka, Darcy S; Owen, Jonathan S; Sahin, Ozgur; Shepard, Kenneth L; Yuste, Rafael
2017-05-01
Dendritic spines are the primary site of excitatory synaptic input onto neurons, and are biochemically isolated from the parent dendritic shaft by their thin neck. However, due to the lack of direct electrical recordings from spines, the influence that the neck resistance has on synaptic transmission, and the extent to which spines compartmentalize voltage, specifically excitatory postsynaptic potentials, albeit critical, remains controversial. Here, we use quantum-dot-coated nanopipette electrodes (tip diameters ∼15-30 nm) to establish the first intracellular recordings from targeted spine heads under two-photon visualization. Using simultaneous somato-spine electrical recordings, we find that back propagating action potentials fully invade spines, that excitatory postsynaptic potentials are large in the spine head (mean 26 mV) but are strongly attenuated at the soma (0.5-1 mV) and that the estimated neck resistance (mean 420 MΩ) is large enough to generate significant voltage compartmentalization. Nanopipettes can thus be used to electrically probe biological nanostructures.
Loss of mTOR-dependent macroautophagy causes autistic-like synaptic pruning deficits.
Tang, Guomei; Gudsnuk, Kathryn; Kuo, Sheng-Han; Cotrina, Marisa L; Rosoklija, Gorazd; Sosunov, Alexander; Sonders, Mark S; Kanter, Ellen; Castagna, Candace; Yamamoto, Ai; Yue, Zhenyu; Arancio, Ottavio; Peterson, Bradley S; Champagne, Frances; Dwork, Andrew J; Goldman, James; Sulzer, David
2014-09-03
Developmental alterations of excitatory synapses are implicated in autism spectrum disorders (ASDs). Here, we report increased dendritic spine density with reduced developmental spine pruning in layer V pyramidal neurons in postmortem ASD temporal lobe. These spine deficits correlate with hyperactivated mTOR and impaired autophagy. In Tsc2 ± ASD mice where mTOR is constitutively overactive, we observed postnatal spine pruning defects, blockade of autophagy, and ASD-like social behaviors. The mTOR inhibitor rapamycin corrected ASD-like behaviors and spine pruning defects in Tsc2 ± mice, but not in Atg7(CKO) neuronal autophagy-deficient mice or Tsc2 ± :Atg7(CKO) double mutants. Neuronal autophagy furthermore enabled spine elimination with no effects on spine formation. Our findings suggest that mTOR-regulated autophagy is required for developmental spine pruning, and activation of neuronal autophagy corrects synaptic pathology and social behavior deficits in ASD models with hyperactivated mTOR. Copyright © 2014 Elsevier Inc. All rights reserved.
Random positions of dendritic spines in human cerebral cortex.
Morales, Juan; Benavides-Piccione, Ruth; Dar, Mor; Fernaud, Isabel; Rodríguez, Angel; Anton-Sanchez, Laura; Bielza, Concha; Larrañaga, Pedro; DeFelipe, Javier; Yuste, Rafael
2014-07-23
Dendritic spines establish most excitatory synapses in the brain and are located in Purkinje cell's dendrites along helical paths, perhaps maximizing the probability to contact different axons. To test whether spine helixes also occur in neocortex, we reconstructed >500 dendritic segments from adult human cortex obtained from autopsies. With Fourier analysis and spatial statistics, we analyzed spine position along apical and basal dendrites of layer 3 pyramidal neurons from frontal, temporal, and cingulate cortex. Although we occasionally detected helical positioning, for the great majority of dendrites we could not reject the null hypothesis of spatial randomness in spine locations, either in apical or basal dendrites, in neurons of different cortical areas or among spines of different volumes and lengths. We conclude that in adult human neocortex spine positions are mostly random. We discuss the relevance of these results for spine formation and plasticity and their functional impact for cortical circuits. Copyright © 2014 the authors 0270-6474/14/3410078-07$15.00/0.
Hogan, B A; Hogan, N A; Vos, P M; Eustace, S J; Kenny, P J
2010-06-01
Injuries to the cervical spine (C-spine) are among the most serious in rugby and are well documented. Front-row players are particularly at risk due to repetitive high-intensity collisions in the scrum. This study evaluates degenerative changes of the C-spine and associated symptomatology in front-row rugby players. C-spine radiographs from 14 professional rugby players and controls were compared. Players averaged 23 years of playing competitive rugby. Two consultant radiologists performed a blind review of radiographs evaluating degeneration of disc spaces and apophyseal joints. Clinical status was assessed using a modified AAOS/NASS/COSS cervical spine outcomes questionnaire. Front-row rugby players exhibited significant radiographic evidence of C-spine degenerative changes compared to the non-rugby playing controls (P < 0.005). Despite these findings the rugby players did not exhibit increased symptoms. This highlights the radiologic degenerative changes of the C-spine of front-row rugby players. However, these changes do not manifest themselves clinically or affect activities of daily living.
Vassilieva, Anna B; Galoyan, Eduard A; Gogoleva, Svetlana S; Poyarkov, Nikolay A
2014-05-20
We describe two new mountain-dwelling microhylid species of the genus Kalophrynus from the southern part of the Annamite Mountains in Vietnam. The two new species differ from all known congeners in morphological characters and mtDNA; phylogenetically, they form a sister clade to the large-bodied K. interlineatus (1009 bp, 16S rRNA gene, mtDNA). Both species share the following characteristics: snout pointed in dorsal and lateral views, slightly sloping in profile; tympanum distinct, smaller than eye in diameter; toe webbing moderate; outer metatarsal tubercle present; light dorsolateral line absent. Kalophrynus cryptophonus sp. nov. from Loc Bao, Lam Dong Province is a small-sized species distinguishing from its congeners by a combination of: SVL 27.9-30.4 mm in males, 23.4 mm in female; canthus rostralis indistinct; males with large sharp conical spines on the skin covering mandible margins and finely asperous nuptial pads on the dorsal surface of fingers I-III; dark ocelli in the inguinal region usually present, small, without a light border; anterior palatal dermal ridge short, restricted to medial part of palate. Kalophrynus honbaensis sp. nov. from Hon Ba, Khanh Hoa Province is a medium-sized Kalophrynus, distinguishing from its congeners by a combination of: SVL 26.7-36.8 mm in males; canthus rostralis distinct; males without distinguishable spines on the mandible margins nor the nuptial pads; dark ocelli in the inguinal region present, large, without a distinct light border, anterior palatal dermal ridge developed, parallel to posterior one. Kalophrynus cryptophonus sp. nov. reproduces in hollow bamboo stems; we describe larval morphology and bioacoustics of this species in relation to phytotelm breeding. A review of the distribution of the genus Kalophrynus in Indochina is provided.
Fractures in Relation to Menstrual Status and Bone Parameters in Young Athletes
Ackerman, Kathryn E.; Cano Sokoloff, Natalia; Maffazioli, Giovana De Nardo; Clarke, Hannah; Lee, Hang; Misra, Madhusmita
2014-01-01
Introduction To compare fracture prevalence in oligo-amenorrheic athletes (AA), eumenorrheic athletes (EA), and non-athletes (NA) and determine relationships with bone density, structure and strength estimates. Methods 175 females (100 AA, 35 EA, and 40 NA) 14–25 yo were studied. Lifetime fracture history was obtained through participant interviews. Areal BMD was assessed by DXA at the spine, hip and whole body (WB). Bone structure was assessed by HRpQCT at the radius and tibia, and strength by finite element analysis. Results AA, EA, and NA did not differ in age, sexual maturity, or height. AA had lower BMI, and older menarchal age than EA and NA (p≤0.001). BMD Z-scores were lower in AA vs. EA at the total hip, femoral neck, spine, and whole body (p≤0.001). Lifetime fracture risk was higher in AA than EA and NA (47%, 25.7%, 12.5%, p≤0.001), largely driven by stress fractures in AA vs. EA and NA (32% vs. 5.9% vs. 0%). In AA, those who fractured had lower lumbar and WB BMD Z-scores, vBMD of outer trabecular region in radius and tibia, and trabecular thickness of the radius (p≤0.05). In AA, those who had 2 stress fractures had lower lumbar and WB BMD Z-scores, total cross-sectional area, trabecular vBMD, stiffness and failure load at radius; and lower stiffness and failure load at tibia versus those with <2 stress fracture (p≤0.05). Conclusion Weight-bearing athletic activity increases BMD, but may increase stress fracture risk in those with menstrual dysfunction. Bone microarchitecture and strength differences are more pronounced in AA with multiple stress fractures. This is the first study to examine fractures in relation to bone structure in adolescent female athletes. PMID:25397605
Evidence for the Magnetic Breakout Model in AN Equatorial Coronal-Hole Jet
NASA Astrophysics Data System (ADS)
Kumar, P.; Karpen, J.; Antiochos, S. K.; Wyper, P. F.; DeVore, C. R.; DeForest, C. E.
2017-12-01
We analyzed an equatorial coronal-hole jet observed by Solar Dynamic Observatory (SDO)/AtmosphericImaging Assembly (AIA). The source-region magnetic field structure is consistent withthe embedded-bipole topology that we identified and modeled previously as a source of coronal jets. Theinitial brightening was observed below a sigmoid structure about 25 min before the onset of an untwisting jet.A circular magnetic flux rope with a mini-filament rose slowly at the speed of ˜15 km/s , then accelerated(˜126 km/s) during the onset of explosive breakout reconnection. Multiple plasmoids, propagating upward(˜135 km/s) and downward (˜55 km/s ), were detected behind the rising flux rope shortly before andduring explosive breakout reconnection. The jet was triggered when the rising flux rope interacted with theoverlying magnetic structures near the outer spine. This event shows a clear evidence of reconnection not onlybelow the flux rope but also a breakout reconnection above the flux rope. During the breakout reconnection,we observed heating of the flux rope, deflection of loops near the spine, and formation of multiple ribbons.The explosive breakout reconnection destroyed the flux rope that produced an untwisting jet with a speed of˜380 km/s . HMI magnetograms reveal the shear motion at theeruption site, but do not show any significant flux emergence or cancellation during or 2 hours before theeruption. Therefore, the free energy powering this jet most likely originated in magnetic shear concentratedat the polarity inversion line within the embedded bipole-a mini-filament channel-possibly created by helicitycondensation. The result of of a statistical study of multiple jets will also be discussed.
A Multicenter Program to Implement the Canadian C-Spine Rule by Emergency Department Triage Nurses.
Stiell, Ian G; Clement, Catherine M; Lowe, Maureen; Sheehan, Connor; Miller, Jacqueline; Armstrong, Sherry; Bailey, Brenda; Posselwhite, Kerry; Langlais, Jannick; Ruddy, Karin; Thorne, Susan; Armstrong, Alison; Dain, Catherine; Perry, Jeffrey J; Vaillancourt, Christian
2018-05-02
The Canadian C-Spine Rule has been widely applied by emergency physicians to safely reduce use of cervical spine imaging. Our objective is to evaluate the clinical effect and safety of real-time Canadian C-Spine Rule implementation by emergency department (ED) triage nurses to remove cervical spine immobilization. We conducted this multicenter, 2-phase, prospective cohort program at 9 hospital EDs and included alert trauma patients presenting with neck pain or with cervical spine immobilization. During phase 1, ED nurses were trained and then had to demonstrate competence before being certified. During phase 2, certified nurses were empowered by a medical directive to "clear" the cervical spine of patients, allowing them to remove cervical spine immobilization and to triage to a less acute area. The primary outcomes were clinical effect (cervical spine clearance by nurses) and safety (missed clinically important cervical spine injuries). In phase 1, 312 nurses evaluated 3,098 patients. In phase 2, 180 certified nurses enrolled 1,408 patients (mean age 43.1 years, women 52.3%, collision 56.5%, and cervical spine injury 1.1%). In phase 2 and for the 806 immobilized ambulance patients, the primary outcome of immobilization removal by nurses was 41.1% compared with 0% before the program. The primary safety outcome of cervical spine injuries missed by nurses was 0. Time to discharge was reduced by 26.0% (3.4 versus 4.6 hours) for patients who had immobilization removed. In only 1.3% of cases did nurses indicate their discomfort with applying the Canadian C-Spine Rule. We clearly demonstrated that ED triage nurses can successfully implement the Canadian C-Spine Rule, leading to more rapid and comfortable management of patients without any threat to patient safety. Widespread adoption of this approach should improve care and comfort for trauma patients, and could decrease length of stay in our very crowded EDs. Copyright © 2018 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
Huang, H.; Nightingale, R. W.
2018-01-01
Objectives Loss of motion following spine segment fusion results in increased strain in the adjacent motion segments. However, to date, studies on the biomechanics of the cervical spine have not assessed the role of coupled motions in the lumbar spine. Accordingly, we investigated the biomechanics of the cervical spine following cervical fusion and lumbar fusion during simulated whiplash using a whole-human finite element (FE) model to simulate coupled motions of the spine. Methods A previously validated FE model of the human body in the driver-occupant position was used to investigate cervical hyperextension injury. The cervical spine was subjected to simulated whiplash exposure in accordance with Euro NCAP (the European New Car Assessment Programme) testing using the whole human FE model. The coupled motions between the cervical spine and lumbar spine were assessed by evaluating the biomechanical effects of simulated cervical fusion and lumbar fusion. Results Peak anterior longitudinal ligament (ALL) strain ranged from 0.106 to 0.382 in a normal spine, and from 0.116 to 0.399 in a fused cervical spine. Strain increased from cranial to caudal levels. The mean strain increase in the motion segment immediately adjacent to the site of fusion from C2-C3 through C5-C6 was 26.1% and 50.8% following single- and two-level cervical fusion, respectively (p = 0.03, unpaired two-way t-test). Peak cervical strains following various lumbar-fusion procedures were 1.0% less than those seen in a healthy spine (p = 0.61, two-way ANOVA). Conclusion Cervical arthrodesis increases peak ALL strain in the adjacent motion segments. C3-4 experiences greater changes in strain than C6-7. Lumbar fusion did not have a significant effect on cervical spine strain. Cite this article: H. Huang, R. W. Nightingale, A. B. C. Dang. Biomechanics of coupled motion in the cervical spine during simulated whiplash in patients with pre-existing cervical or lumbar spinal fusion: A Finite Element Study. Bone Joint Res 2018;7:28–35. DOI: 10.1302/2046-3758.71.BJR-2017-0100.R1. PMID:29330341
Huang, H; Nightingale, R W; Dang, A B C
2018-01-01
Loss of motion following spine segment fusion results in increased strain in the adjacent motion segments. However, to date, studies on the biomechanics of the cervical spine have not assessed the role of coupled motions in the lumbar spine. Accordingly, we investigated the biomechanics of the cervical spine following cervical fusion and lumbar fusion during simulated whiplash using a whole-human finite element (FE) model to simulate coupled motions of the spine. A previously validated FE model of the human body in the driver-occupant position was used to investigate cervical hyperextension injury. The cervical spine was subjected to simulated whiplash exposure in accordance with Euro NCAP (the European New Car Assessment Programme) testing using the whole human FE model. The coupled motions between the cervical spine and lumbar spine were assessed by evaluating the biomechanical effects of simulated cervical fusion and lumbar fusion. Peak anterior longitudinal ligament (ALL) strain ranged from 0.106 to 0.382 in a normal spine, and from 0.116 to 0.399 in a fused cervical spine. Strain increased from cranial to caudal levels. The mean strain increase in the motion segment immediately adjacent to the site of fusion from C2-C3 through C5-C6 was 26.1% and 50.8% following single- and two-level cervical fusion, respectively (p = 0.03, unpaired two-way t -test). Peak cervical strains following various lumbar-fusion procedures were 1.0% less than those seen in a healthy spine (p = 0.61, two-way ANOVA). Cervical arthrodesis increases peak ALL strain in the adjacent motion segments. C3-4 experiences greater changes in strain than C6-7. Lumbar fusion did not have a significant effect on cervical spine strain. Cite this article : H. Huang, R. W. Nightingale, A. B. C. Dang. Biomechanics of coupled motion in the cervical spine during simulated whiplash in patients with pre-existing cervical or lumbar spinal fusion: A Finite Element Study. Bone Joint Res 2018;7:28-35. DOI: 10.1302/2046-3758.71.BJR-2017-0100.R1. © 2018 Huang et al.
Daniels, Alan H; Ames, Christopher P; Smith, Justin S; Hart, Robert A
2014-12-03
Current spine surgeon training in the United States consists of either an orthopaedic or neurological surgery residency, followed by an optional spine surgery fellowship. Resident spine surgery procedure volume may vary between and within specialties. The Accreditation Council for Graduate Medical Education surgical case logs for graduating orthopaedic surgery and neurosurgery residents from 2009 to 2012 were examined and were compared for spine surgery resident experience. The average number of reported spine surgery procedures performed during residency was 160.2 spine surgery procedures performed by orthopaedic surgery residents and 375.0 procedures performed by neurosurgery residents; the mean difference of 214.8 procedures (95% confidence interval, 196.3 to 231.7 procedures) was significant (p = 0.002). From 2009 to 2012, the average total spinal surgery procedures logged by orthopaedic surgery residents increased 24.3% from 141.1 to 175.4 procedures, and those logged by neurosurgery residents increased 6.5% from 367.9 to 391.8 procedures. There was a significant difference (p < 0.002) in the average number of spinal deformity procedures between graduating orthopaedic surgery residents (9.5 procedures) and graduating neurosurgery residents (2.0 procedures). There was substantial variability in spine surgery exposure within both specialties; when comparing the top 10% and bottom 10% of 2012 graduates for spinal instrumentation or arthrodesis procedures, there was a 13.1-fold difference for orthopaedic surgery residents and an 8.3-fold difference for neurosurgery residents. Spine surgery procedure volumes in orthopaedic and neurosurgery residency training programs vary greatly both within and between specialties. Although orthopaedic surgery residents had an increase in the number of spine procedures that they performed from 2009 to 2012, they averaged less than half of the number of spine procedures performed by neurological surgery residents. However, orthopaedic surgery residents appear to have greater exposure to spinal deformity than neurosurgery residents. Furthermore, orthopaedic spine fellowship training provides additional spine surgery case exposure of approximately 300 to 500 procedures; thus, before entering independent practice, when compared with neurosurgery residents, most orthopaedic spine surgeons complete as many spinal procedures or more. Although case volume is not the sole determinant of surgical skills or clinical decision making, variability in spine surgery procedure volume does exist among residency programs in the United States. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Prevalence of joint-related pain in the extremities and spine in five groups of top athletes.
Jonasson, Pall; Halldin, Klas; Karlsson, Jon; Thoreson, Olof; Hvannberg, Jonas; Swärd, Leif; Baranto, Adad
2011-09-01
Joint-related pain conditions from the spine and extremities are common among top athletes. The frequency of back pain has, however, been studied in more detail, and the frequency of low-back pain in top athletes in different high-load sports has been reported to be as high as 85%. Sport-related pain from different joints in the extremities is, however, infrequently reported on in the literature. Seventy-five male athletes, i.e. divers, weight-lifters, wrestlers, orienteers and ice-hockey players and 12 non-athletes (control group) were included in the study. A specific self-assessed pain-oriented questionnaire related to the cervical, thoracic and lumbar spine, as well as the various joints, i.e. shoulders, elbows, wrists, hips, knees and ankles, was filled out by the athletes and the non-athletes. The overall frequency of pain reported by the athletes during the last week/last year was as follows; cervical spine 35/55%; thoracic spine 22/33%; lumbar spine 50/68%; shoulder 10/21%; elbow 7/7%; wrist 7/8%; hip 15/23%; knee 22/44%; and ankle 11/25%. The corresponding values for non-athletes were cervical spine 9/36%; thoracic spine 17/33%; lumbar spine 36/50%; shoulder 0/9%; elbow 9/0%; wrist 0/0%; hip 9/16%; knee 10/9%; and ankle 0/0%. A higher percentage of athletes reported pain in almost all joint regions, but there were no statistically significant differences (n.s.), with the exception of the knees (P = 0.05). Over the last year, athletes reporting the highest pain frequency in the lumbar spine were ice-hockey players and, in the cervical spine, wrestlers and ice-hockey players. The highest levels of knee pain were found among wrestlers and ice-hockey players, whereas the highest levels for wrist pain were found among divers, hip pain among weight-lifters, orienteers and divers and ankle pain among orienteers. For the thoracic spine, shoulder and elbow regions, only minor differences were found. There was no statistically significant difference in prevalence of pain in the neck, spine and joints between top athletes in different sports or between athletes and non-athletes. However, pain in one spinal region was correlated to reported pain in other regions of the spine. Moreover, pain in the spine was also correlated to pain in the shoulders, hips and knees.
Holding fixture for metallographic mount polishing
Barth, C.H.; Cramer, C.E.
1997-12-30
A fixture is described for holding mounted specimens for polishing, having an arm; a body attached to one end of the arm, the body having at least one flange having an opening to accommodate a mounted specimen; and a means applying pressure against the outer surface of the mounted specimen to hold the specimen in contact with the polishing surface. 3 figs.
USAF Dehumidification Efforts for Corrosion Control
2011-08-16
Stored AGE Renewable energy powers dehumidification equipment (DH) DH maintains dry air in storage booths, protecting AGE equipment from...lighting also powered by renewable energy 11 CHP Shelters • Used to prevent corrosion on outer skin • Being developed for the F-22 at...DH can be Sheltered or Unsheltered • Air Dehydration Units - Uses a self rejuvenating desiccant wheel dehumidifier - Closed or open loop
NASA Astrophysics Data System (ADS)
Tsai, Chih-Hung; Zhang, Jia-Wei; Liao, Yi-Yi; Liu, Hao-Li
2016-04-01
Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r 2 = 0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.
Tsai, Chih-Hung; Zhang, Jia-Wei; Liao, Yi-Yi; Liu, Hao-Li
2016-04-07
Burst-tone focused ultrasound exposure in the presence of microbubbles has been demonstrated to be effective at inducing temporal and local opening of the blood-brain barrier (BBB), which promises significant clinical potential to deliver therapeutic molecules into the central nervous system (CNS). Traditional contrast-enhanced imaging confirmation after focused ultrasound (FUS) exposure serves as a post-operative indicator of the effectiveness of FUS-BBB opening, however, an indicator that can concurrently report the BBB status and BBB-opening effectiveness is required to provide effective feedback to implement this treatment clinically. In this study, we demonstrate the use of subharmonic acoustic emission detection with implementation on a confocal dual-frequency piezoelectric ceramic structure to perform real-time monitoring of FUS-BBB opening. A confocal dual-frequency (0.55 MHz/1.1 MHz) focused ultrasound transducer was designed. The 1.1 MHz spherically-curved ceramic was employed to deliver FUS exposure to induce BBB-opening, whereas the outer-ring 0.55 MHz ceramic was employed to detect the subharmonic acoustic emissions originating from the target position. In stage-1 experiments, we employed spectral analysis and performed an energy spectrum density (ESD) calculation. An optimized 0.55 MHz ESD level change was shown to effectively discriminate the occurrence of BBB-opening. Wideband acoustic emissions received from 0.55 MHz ceramics were also analyzed to evaluate its correlations with erythrocyte extravasations. In stage-2 real-time monitoring experiments, we applied the predetermined ESD change as a detection threshold in PC-controlled algorithm to predict the FUS exposure intra-operatively. In stage-1 experiment, we showed that subharmonic ESD presents distinguishable dynamics between intact BBB and opened BBB, and therefore a threshold ESD change level (5.5 dB) can be identified for BBB-opening prediction. Using this ESD change threshold detection as a surrogate to on/off control the FUS exposure in stage-2 experiments, we demonstrated both excellent sensitivity (92%) and specificity (92.3%) in discriminating BBB-opening occurrence can be obtained in animal treatments, while concurrently achieving a high positive predicted value (95.8%). Wideband ESD was also highly correlated with the occurrence and level of erythrocyte extravasations (r (2) = 0.81). The proposed system configuration and corresponding analysis based on subharmonic acoustic emissions has the potential to be implemented as a real-time feedback control structure for reliable indication of intact FUS-BBB opening for CNS brain drug delivery.
Exploration of the pore structure of a peptide-gated Na+channel
Poët, Mallorie; Tauc, Michel; Lingueglia, Eric; Cance, Peggy; Poujeol, Philippe; Lazdunski, Michel; Counillon, Laurent
2001-01-01
The FMRF-amide-activated sodium channel (FaNaC), a member of the ENaC/Degenerin family, is a homotetramer, each subunit containing two transmembrane segments. We changed independently every residue of the first transmembrane segment (TM1) into a cysteine and tested each position’s accessibility to the cysteine covalent reagents MTSET and MTSES. Eleven mutants were accessible to the cationic MTSET, showing that TM1 faces the ion translocation pathway. This was confirmed by the accessibility of cysteines present in the acid-sensing ion channels and other mutations introduced in FaNaC TM1. Modification of accessibilities for positions 69, 71 and 72 in the open state shows that the gating mechanism consists of the opening of a constriction close to the intracellular side. The anionic MTSES did not penetrate into the channel, indicating the presence of a charge selectivity filter in the outer vestibule. Furthermore, amiloride inhibition resulted in the channel occlusion in the middle of the pore. Summarizing, the ionic pore of FaNaC includes a large aqueous cavity, with a charge selectivity filter in the outer vestibule and the gate close to the interior. PMID:11598003
DOE Office of Scientific and Technical Information (OSTI.GOV)
Imamura, Takeshi; Ando, Hiroki; Toda, Tomoaki
Radio scintillation observations have been unable to probe flow speeds in the low corona where the scattering of radio waves is exceedingly strong. Here we estimate outflow speeds continuously from the vicinity of the Sun to the outer corona (heliocentric distances of 1.5-20.5 solar radii) by applying the strong scattering theory to radio scintillations for the first time, using the Akatsuki spacecraft as the radio source. Small, nonzero outflow speeds were observed over a wide latitudinal range in the quiet-Sun low corona, suggesting that the supply of plasma from closed loops to the solar wind occurs over an extended area.more » The existence of power-law density fluctuations down to the scale of 100 m was suggested, which is indicative of well-developed turbulence which can play a key role in heating the corona. At higher altitudes, a rapid acceleration typical of radial open fields is observed, and the temperatures derived from the speed profile show a distinct maximum in the outer corona. This study opened up a possibility of observing detailed flow structures near the Sun from a vast amount of existing interplanetary scintillation data.« less