Sample records for open volume defects

  1. Thermally promoted evolution of open-volume defects and Cu precipitates in the deformed FeCu alloys

    NASA Astrophysics Data System (ADS)

    Jin, Shuoxue; Cao, Xingzhong; Cheng, Guodong; Lian, Xiangyu; Zhu, Te; Zhang, Peng; Yu, Runsheng; Wang, Baoyi

    2018-04-01

    We have studied the effect of isothermal annealing on the evolution of the open-volume defect and the Cu precipitate in deformed Fe0.15Cu, Fe0.3Cu and Fe0.6Cu alloys. Using the coincidence Doppler broadening, positron annihilation lifetime and the S-W couples, the evolution of local electronic circumstance around the annihilation sites, open-volume defects and interaction between open-volume defects and Cu precipitates were measured as a function of the isothermal annealing temperatures. Cold rolling deformation induced an obvious increment in S parameters due to the formation of open-volume defects. Annealing not only resulted in gradual recovery of open-volume defects and Cu thermal precipitation, but also promoted the combination and interaction between defects and Cu precipitates. The interaction between open-volume defects and Cu precipitates was revealed clearly by the view point of S-W relationship. The S-W interaction for the different CumVn complexes was also calculated theoretically by MIKA-Doppler, which supports our experimental observations qualitatively. The results indicate that open-volume defects were formed first after cold rolling, followed by the Cu precipitation and recovery of open-volume defects, Cu precipitates recovered at the end. It is interesting that the trajectory of (S, W) points with increasing annealing temperature formed a similar closed "Parallelogram" shape. It is benefit for revealing the behavior of Cu thermal precipitation and their evolution in various Cu-bearing steels under thermal treatment. In addition, we also investigated the Cu content effect on the Cu precipitation in FeCu alloys, and the Cu precipitate phenomenon was enhanced in higher Cu content alloys.

  2. Positron beam study of indium tin oxide films on GaN

    NASA Astrophysics Data System (ADS)

    Cheung, C. K.; Wang, R. X.; Beling, C. D.; Djurisic, A. B.; Fung, S.

    2007-02-01

    Variable energy Doppler broadening spectroscopy has been used to study open-volume defects formed during the fabrication of indium tin oxide (ITO) thin films grown by electron-beam evaporation on n-GaN. The films were prepared at room temperature, 200 and 300 °C without oxygen and at 200 °C under different oxygen partial pressures. The results show that at elevated growth temperatures the ITO has fewer open volume sites and grows with a more crystalline structure. High temperature growth, however, is not sufficient in itself to remove open volume defects at the ITO/GaN interface. Growth under elevated temperature and under partial pressure of oxygen is found to further reduce the vacancy type defects associated with the ITO film, thus improving the quality of the film. Oxygen partial pressures of 6 × 10-3 mbar and above are found to remove open volume defects associated with the ITO/GaN interface. The study suggests that, irrespective of growth temperature and oxygen partial pressure, there is only one type of defect in the ITO responsible for trapping positrons, which we tentatively attribute to the oxygen vacancy.

  3. Positron annihilation spectroscopy in doped p-type ZnO

    NASA Astrophysics Data System (ADS)

    Majumdar, Sayanee; Sanyal, D.

    2011-07-01

    Positron annihilation lifetime (PAL) spectroscopy has been used to investigate the vacancy type defect of the Li and N doped ZnO. The mono-vacancies, shallow -vacancies and open volume defects have been found in both the Li and N doped ZnO. The mono-vacancies, shallow-vacancies and open volume defects increase in N-doped ZnO as the size of N is quite high compared to Li. Positron annihilation study showed that the doping above 1-3% Li and 3-4% N in ZnO are not required in order to achieve low resistivity, high hole concentration and good mobility.

  4. Defect evolution and impurity migration in Na-implanted ZnO

    NASA Astrophysics Data System (ADS)

    Neuvonen, Pekka T.; Vines, Lasse; Venkatachalapathy, Vishnukanthan; Zubiaga, Asier; Tuomisto, Filip; Hallén, Anders; Svensson, Bengt G.; Kuznetsov, Andrej Yu.

    2011-11-01

    Secondary ion mass spectrometry (SIMS) and positron annihilation spectroscopy (PAS) have been applied to study impurity migration and open volume defect evolution in Na+ implanted hydrothermally grown ZnO samples. In contrast to most other elements, the presence of Na tends to decrease the concentration of open volume defects upon annealing and for temperatures above 600∘C, Na exhibits trap-limited diffusion correlating with the concentration of Li. A dominating trap for the migrating Na atoms is most likely Li residing on Zn site, but a systematic analysis of the data suggests that zinc vacancies also play an important role in the trapping process.

  5. Formation of vacancy clusters and cavities in He-implanted silicon studied by slow-positron annihilation spectroscopy

    NASA Astrophysics Data System (ADS)

    Brusa, Roberto S.; Karwasz, Grzegorz P.; Tiengo, Nadia; Zecca, Antonio; Corni, Federico; Tonini, Rita; Ottaviani, Gianpiero

    2000-04-01

    The depth profile of open volume defects has been measured in Si implanted with He at an energy of 20 keV, by means of a slow-positron beam and the Doppler broadening technique. The evolution of defect distributions has been studied as a function of isochronal annealing in two series of samples implanted at the fluence of 5×1015 and 2×1016 He cm-2. A fitting procedure has been applied to the experimental data to extract a positron parameter characterizing each open volume defect. The defects have been identified by comparing this parameter with recent theoretical calculations. In as-implanted samples the major part of vacancies and divacancies produced by implantation is passivated by the presence of He. The mean depth of defects as seen by the positron annihilation technique is about five times less than the helium projected range. During the successive isochronal annealing the number of positron traps decreases, then increases and finally, at the highest annealing temperatures, disappears only in the samples implanted at the lowest fluence. A minimum of open volume defects is reached at the annealing temperature of 250 °C in both series. The increase of open volume defects at temperatures higher than 250 °C is due to the appearance of vacancy clusters of increasing size, with a mean depth distribution that moves towards the He projected range. The appearance of vacancy clusters is strictly related to the out diffusion of He. In the samples implanted at 5×1015 cm-2 the vacancy clusters are mainly four vacancy agglomerates stabilized by He related defects. They disappear starting from an annealing temperature of 700 °C. In the samples implanted at 2×1016 cm-2 and annealed at 850-900 °C the vacancy clusters disappear and only a distribution of cavities centered around the He projected range remains. The role of vacancies in the formation of He clusters, which evolve in bubble and then in cavities, is discussed.

  6. Positron annihilation and X-ray diffraction studies on tin oxide thin films

    NASA Astrophysics Data System (ADS)

    Prabakar, K.; Abhaya, S.; Krishnan, R.; Kalavathi, S.; Dash, S.; Jayapandian, J.; Amarendra, G.

    2009-04-01

    Positron annihilation spectroscopy along with glancing incidence X-ray diffraction have been used to investigate tin oxide thin films grown on Si by pulsed laser deposition. The films were prepared at room temperature and at 670 K under oxygen partial pressure. As-grown samples are amorphous and are found to contain large concentration of open volume sites (vacancy defects). Post-deposition annealing of as-grown samples at 970 K is found to drastically reduce the number of open volume sites and the film becomes crystalline. However, film grown under elevated temperature and under partial pressure of oxygen is found to exhibit a lower S-parameter, indicating lower defect concentration. Based on the analysis of experimental positron annihilation results, the defect-sensitive S-parameter and the overlayer thickness of tin oxide thin films are deduced. S- W correlation plots exhibit distinct positron trapping defect states in three samples.

  7. Microstructure of thermally grown and deposited alumina films probed with positrons

    NASA Astrophysics Data System (ADS)

    Somieski, Bertram; Hulett, Lester D.; Xu, Jun; Pint, Bruce A.; Tortorelli, Peter F.; Nielsen, Bent; Asoka-Kumar, Palakkal; Suzuki, Ryoichi; Ohdaira, Toshiyuki

    1999-03-01

    Aluminum oxide films used for corrosion protection of iron and nickel aluminides were generated by substrate oxidation as well as plasma and physical vapor depositions. The films grown by oxidation were crystalline. The others were amorphous. Defect structures of the films were studied by positron spectroscopy techniques. Lifetimes of the positrons, and Doppler broadening of the γ photons generated by their annihilation, were measured as functions of the energies with which they were injected. In this manner, densities and sizes of the defects were determined as functions of depths from the outer surfaces of the films. Alumina films generated by oxidation had high densities of open volume defects, mainly consisting of a few aggregated vacancies. In the outer regions of the films the structures of the defects did not depend on substrate compositions. Positron lifetime measurements, and the S and W parameters extracted from Doppler broadening spectra, showed uniform distributions of defects in the crystalline Al2O3 films grown on nickel aluminide substrates, but these data indicated intermediate layers of higher defect contents at the film/substrate interfaces of oxides grown on iron aluminide substrates. Amorphous films generated by plasma and physical vapor deposition had much larger open volume defects, which caused the average lifetimes of the injected positrons to be significantly longer. The plasma deposited film exhibited a high density of large cavities.

  8. Positron lifetime beam for defect studies in thin epitaxial semiconductor structures

    NASA Astrophysics Data System (ADS)

    Laakso, A.; Saarinen, K.; Hautojärvi, P.

    2001-12-01

    Positron annihilation spectroscopies are methods for direct identification of vacancy-type defects by measuring positron lifetime and Doppler broadening of annihilation radiation and providing information about open volume, concentration and atoms surrounding the defect. Both these techniques are easily applied to bulk samples. Only the Doppler broadening spectroscopy can be employed in thin epitaxial samples by utilizing low-energy positron beams. Here we describe the positron lifetime beam which will provide us with a method to measure lifetime in thin semiconductor layers.

  9. Native point defects in GaSb

    NASA Astrophysics Data System (ADS)

    Kujala, J.; Segercrantz, N.; Tuomisto, F.; Slotte, J.

    2014-10-01

    We have applied positron annihilation spectroscopy to study native point defects in Te-doped n-type and nominally undoped p-type GaSb single crystals. The results show that the dominant vacancy defect trapping positrons in bulk GaSb is the gallium monovacancy. The temperature dependence of the average positron lifetime in both p- and n-type GaSb indicates that negative ion type defects with no associated open volume compete with the Ga vacancies. Based on comparison with theoretical predictions, these negative ions are identified as Ga antisites. The concentrations of these negatively charged defects exceed the Ga vacancy concentrations nearly by an order of magnitude. We conclude that the Ga antisite is the native defect responsible for p-type conductivity in GaSb single crystals.

  10. Native point defects in GaSb

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kujala, J.; Segercrantz, N.; Tuomisto, F.

    2014-10-14

    We have applied positron annihilation spectroscopy to study native point defects in Te-doped n-type and nominally undoped p-type GaSb single crystals. The results show that the dominant vacancy defect trapping positrons in bulk GaSb is the gallium monovacancy. The temperature dependence of the average positron lifetime in both p- and n-type GaSb indicates that negative ion type defects with no associated open volume compete with the Ga vacancies. Based on comparison with theoretical predictions, these negative ions are identified as Ga antisites. The concentrations of these negatively charged defects exceed the Ga vacancy concentrations nearly by an order of magnitude.more » We conclude that the Ga antisite is the native defect responsible for p-type conductivity in GaSb single crystals.« less

  11. Observation of interface defects in thermally oxidized SiC using positron annihilation

    NASA Astrophysics Data System (ADS)

    Dekker, James; Saarinen, Kimmo; Ólafsson, Halldór; Sveinbjörnsson, Einar Ö.

    2003-03-01

    Positron annihilation has been applied to study thermally oxidized 4H- and 6H-SiC. The SiC/SiO2 interface is found to contain a high density of open-volume defects. The positron trapping at the interface defects correlates with the charge of the interface determined by capacitance-voltage experiments. For oxides grown on n-SiC substrates, the positron annihilation characteristics at these defects are nearly indistinguishable from those of a silicon/oxide interface, with no discernable contribution from C-related bonds or carbon clusters. These results indicate that those defects at the SiC/oxide interface, which are visible to positrons, are similar to those at the Si/oxide interface. The positron annihilation characteristics suggest that these defects are vacancies surrounded by oxygen atoms.

  12. Recombinant human bone morphogenetic protein-2 use in the off-label treatment of nonunions and acute fractures: a retrospective review.

    PubMed

    Starman, James S; Bosse, Michael J; Cates, Casey A; Norton, H James

    2012-03-01

    Recombinant human bone morphogenetic protein-2 (BMP-2) is Food and Drug Administration-approved for use in acute open tibial shaft fractures. Some surgeons, however, also use BMP-2 in an "off-label" application for other acute fractures and for nonunion care. This retrospective study was performed to assess radiographic outcomes of off-label uses of BMP-2 for acute fractures and nonunions at our institution. All eligible off-label BMP-2 applications between 2004 and 2008 for acute fractures or nonunions were reviewed. Univariate and multivariate analyses were completed to identify patient and clinical factors that could predict radiographic success or failure of the procedure. One hundred sixteen of 145 BMP-2 applications in 104 of 128 patients met inclusion and exclusion criteria. The overall radiographic union rate was 66% (76 of 116). In the univariate analysis, five factors correlated with significantly higher union rate: volume of bone defect <4 cm3, >2 cortices in contact at the index procedure, male gender, body mass index <30, and history of closed fracture pattern. Within the multivariate analysis, factors independently predictive of radiographic union included open versus closed fracture, gender, and volume of bone defect. Off-label use of BMP-2 in acute fractures and nonunions resulted in a 66% success rate. It remains uncertain whether there is any clinical advantage to this approach, but it appears that female gender, open injury, and higher volumes of bone defect may be important negative prognostic factors for obtaining radiographic union. Appropriately powered prospective randomized trials are needed for further clarification, especially in light of the high cost of this treatment.

  13. Definition of mutually optimum NDI and proof test criteria for 2219 aluminum pressure vessels. Volume 1: Methods

    NASA Technical Reports Server (NTRS)

    Schwartzberg, F. R.; King, R. G.; Todd, P. H., Jr.

    1979-01-01

    The requirements for proof testing and nondestructive inspection of aluminum pressure vessels were discussed. The following conclusions are (1) lack-of-fusion weld defects are sufficiently tight in the as-welded condition to be considered undetectable; (2) proof-level loads are required to fully open lack-of-fusion weld defects; (3) significant crack opening occurs at subproof levels so that an inspection enhancement loading treatment designed to avoid catastrophic failure is feasible; (4) currently used proof levels for 2219 pressure vessels are adequate for postproof inspection; (5) quantification of defect size and location using collimated ultrasonic pitch-catch techniques appears sufficiently feasible for tankage to warrant developmental work; (6) for short-time single-cycle pressure-vessel applications, postproof inspection is desirable; and (7) for long-term multiple-cycle pressure-vessel applications, postproof inspection is essential for life assurance.

  14. Structural evolution in Ar+ implanted Si-rich silicon oxide

    NASA Astrophysics Data System (ADS)

    Brusa, R. S.; Karwasz, G. P.; Mariotto, G.; Zecca, A.; Ferragut, R.; Folegati, P.; Dupasquier, A.; Ottaviani, G.; Tonini, R.

    2003-12-01

    Silicon-rich silicon oxide films were deposited by plasma-enhanced chemical vapor deposition. Energy was released into the film by ion bombardment, with the aim of promoting formation of Si nanoclusters and reordering the oxide matrix. The effect of the initial stoichiometry, as well as the evolution of the oxide films due to the ion bombardment and to subsequent thermal treatments, has been studied by depth-resolved positron annihilation Doppler spectroscopy, Raman scattering and Fourier transform infrared spectroscopy. As-deposited films were found to contain an open volume fraction in the form of subnanometric cavities that are positively correlated with oxygen deficiency. No Si aggregates were observed. The ion bombardment was found to promote the formation of amorphous Si nanoclusters, together with a reduction of the open volume in the matrix and a substantial release of hydrogen. It also leaves electrically active sites in the oxide and produces gas-filled vacancy defects in the substrate, with the concentrations depending on the implantation temperature. Thermal treatment at 500 °C removes charge defects in the oxide, but vacancy defects are not completely annealed even at 1100 °C. In one case, heating at 1100 °C produced cavities of about 0.6 nm in the oxide. Transformation of Si nanoclusters into nanocrystals is observed to occur from 800 °C.

  15. Implant-Retained Obturator for an Edentulous Patient with a Hemimaxillectomy Defect Complicated with Microstomia

    PubMed Central

    2016-01-01

    Patient. A 68-year-old man was operated on for squamous cell carcinoma (T3N3M0) of the maxilla creating the hemimaxillary surgical defect on right side. The remaining arch was completely edentulous. There was remarkable limitation in the oral opening with reduced perimeter of the oral cavity due to radiation and surgical scar contracture. This article describes prosthetic rehabilitation by modifying the design of the obturator and achieving the retention with dental implant. Discussion. Severe limitation in the oral opening may occur in clinical situations following the postsurgical management of oral and maxillofacial defects. The prosthetic rehabilitation of the surgical defect in such patients becomes a challenging task due to limited access to the oral cavity. This challenge becomes even more difficult if the patient is edentulous and there are no teeth to gain the retention, stability, and support. Conclusion. In severe microstomia prosthesis insertion and removal can be achieved with modification of the maximum width of the prosthesis. Dental implant retention is useful treatment option in edentulous patients with maxillary surgical defect provided that sufficient bone volume and accessibility are there for implant placement. PMID:27843652

  16. Depth profiling and morphological characterization of AlN thin films deposited on Si substrates using a reactive sputter magnetron

    NASA Astrophysics Data System (ADS)

    Macchi, Carlos; Bürgi, Juan; García Molleja, Javier; Mariazzi, Sebastiano; Piccoli, Mattia; Bemporad, Edoardo; Feugeas, Jorge; Sennen Brusa, Roberto; Somoza, Alberto

    2014-08-01

    It is well-known that the characteristics of aluminum nitride thin films mainly depend on their morphologies, the quality of the film-substrate interfaces and the open volume defects. A study of the depth profiling and morphological characterization of AlN thin films deposited on two types of Si substrates is presented. Thin films of thicknesses between 200 and 400 nm were deposited during two deposition times using a reactive sputter magnetron. These films were characterized by means of X-ray diffraction and imaging techniques (SEM and TEM). To analyze the composition of the films, energy dispersive X-ray spectroscopy was applied. Positron annihilation spectroscopy, specifically Doppler broadening spectroscopy, was used to gather information on the depth profiling of open volume defects inside the films and the AlN films-Si substrate interfaces. The results are interpreted in terms of the structural changes induced in the films as a consequence of changes in the deposition time (i.e., thicknesses) and of the orientation of the substrates.

  17. Positron annihilation spectroscopy studies of bronze exposed to sandblasting at different pressure

    NASA Astrophysics Data System (ADS)

    Kurdyumov, S.; Siemek, K.; Horodek, P.

    2017-11-01

    An application of Doppler broadening of annihilation line spectroscopy to samples of beryllium bronze DIN-CuBe2 exposed to sandblasting is presented in performed studies. It is familiar that sandblasting introduces open-volume defects. Samples were sandblasted under different pressure for 1 minute using 110 μm particles of Al2O3. For a non-defected sample the constant value of S-parameter was detected. In the cases of sandblasted samples, S-parameter decreased when the depth enhanced. In our studies the thicknesses of defected zones were determined (it was c.a. 30 μm for a sample blasted under pressure of 1 bar and 110 μm - for 5 bar), and it was also observed that if sandblasting pressure is higher the defected zone is larger.

  18. Positron annihilation lifetime and photoluminescence studies on single crystalline ZnO

    NASA Astrophysics Data System (ADS)

    Sarkar, A.; Chakrabarti, Mahuya; Ray, S. K.; Bhowmick, D.; Sanyal, D.

    2011-04-01

    The room temperature positron annihilation lifetime for single crystalline ZnO has been measured as 164 ± 1 ps. The single component lifetime value is very close to but higher than the theoretically predicted value of ~ 154 ps. Photoluminescence study (at 10 K) indicates the presence of hydrogen and other defects, mainly acceptor related, in the crystal. Defects related to a lower open volume than zinc vacancies, presumably a complex with two hydrogen atoms, are the major trapping sites in the sample. The bulk positron lifetime in ZnO is expected to be a little less than 164 ps.

  19. Positron annihilation lifetime and photoluminescence studies on single crystalline ZnO.

    PubMed

    Sarkar, A; Chakrabarti, Mahuya; Ray, S K; Bhowmick, D; Sanyal, D

    2011-04-20

    The room temperature positron annihilation lifetime for single crystalline ZnO has been measured as 164 ± 1 ps. The single component lifetime value is very close to but higher than the theoretically predicted value of ~154 ps. Photoluminescence study (at 10 K) indicates the presence of hydrogen and other defects, mainly acceptor related, in the crystal. Defects related to a lower open volume than zinc vacancies, presumably a complex with two hydrogen atoms, are the major trapping sites in the sample. The bulk positron lifetime in ZnO is expected to be a little less than 164 ps.

  20. Identification of vacancy defect complexes in transparent semiconducting oxides ZnO, In2O3 and SnO2.

    PubMed

    Makkonen, Ilja; Korhonen, Esa; Prozheeva, Vera; Tuomisto, Filip

    2016-06-08

    Positron annihilation spectroscopy, when combined with supporting high-quality modeling of positron states and annihilation in matter, is a powerful tool for detailed defect identification of vacancy-type defects in semiconductors and oxides. Here we demonstrate that the Doppler broadening of the positron annihilation radiation is a very sensitive means for observing the oxygen environment around cation vacancies, the main open-volume defects trapping positrons in measurements made for transparent semiconducting oxides. Changes in the positron annihilation signal due to external manipulation such as irradiation and annealing can be correlated with the associated changes in the sizes of the detected vacancy clusters. Our examples for ZnO, In2O3 and SnO2 demonstrate that oxygen vacancies in oxides can be detected directly using positron annihilation spectroscopy when they are complexed with cation vacancies.

  1. Identification of vacancy defect complexes in transparent semiconducting oxides ZnO, In2O3 and SnO2

    NASA Astrophysics Data System (ADS)

    Makkonen, Ilja; Korhonen, Esa; Prozheeva, Vera; Tuomisto, Filip

    2016-06-01

    Positron annihilation spectroscopy, when combined with supporting high-quality modeling of positron states and annihilation in matter, is a powerful tool for detailed defect identification of vacancy-type defects in semiconductors and oxides. Here we demonstrate that the Doppler broadening of the positron annihilation radiation is a very sensitive means for observing the oxygen environment around cation vacancies, the main open-volume defects trapping positrons in measurements made for transparent semiconducting oxides. Changes in the positron annihilation signal due to external manipulation such as irradiation and annealing can be correlated with the associated changes in the sizes of the detected vacancy clusters. Our examples for ZnO, In2O3 and SnO2 demonstrate that oxygen vacancies in oxides can be detected directly using positron annihilation spectroscopy when they are complexed with cation vacancies.

  2. Investigations on the structure of Pb-Ge-Se glasses

    NASA Astrophysics Data System (ADS)

    Kalra, G.; Upadhyay, M.; Sharma, Y.; Abhaya, S.; Murugavel, S.; Amarendra, G.

    2016-05-01

    Chalcogenide glasses have attracted much attention because of their potential application in various solid state devices. In the present work, we report here the detailed thermal, structural, microstructural studies on PbxGe42-xSe58 with (0 ≤ x ≤ 20) glasses. The influence of Pb content on the glass transition temperature, specific heat, and non-reversing enthalphy is observed and discussed qualitatively The Raman spectroscopic studies on the all the glass compositions are carried out and deconvoluted into different structural units. The positron annihilation life-time spectroscopy (PALS) studies helped to understand the nature of defect states present in the glassy system and its variation with Pb content. The concentration of charged defect centers is found to increase, whereas the open volume defect concentration decreases with Pb content in these glasses.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moutanabbir, O.; Scholz, R.; Goesele, U.

    We present a detailed study of the thermal evolution of H ion-induced vacancy related complexes and voids in bulk GaN implanted under ion-cut conditions. By using transmission electron microscopy, we found that the damage band in as-implanted GaN is decorated with a high density of nanobubbles of approx1-2 nm in diameter. Variable energy Doppler broadening spectroscopy showed that this band contains vacancy clusters and voids. In addition to vacancy clusters, the presence of V{sub Ga}, V{sub Ga}-H{sub 2}, and V{sub Ga}V{sub N} complexes was evidenced by pulsed low-energy positron lifetime spectroscopy. Subtle changes upon annealing in these vacancy complexes weremore » also investigated. As a general trend, a growth in open-volume defects is detected in parallel to an increase in both size and density of nanobubbles. The observed vacancy complexes appear to be stable during annealing. However, for temperatures above 450 deg. C, unusually large lifetimes were measured. These lifetimes are attributed to the formation of positronium in GaN. Since the formation of positronium is not possible in a dense semiconductor, our finding demonstrates the presence of sufficiently large open-volume defects in this temperature range. Based on the Tao-Eldrup model, the average lattice opening during thermal annealing was quantified. We found that a void diameter of 0.4 nm is induced by annealing at 600 deg. C. The role of these complexes in the subsurface microcracking is discussed.« less

  4. A hot implantation study on the evolution of defects in He ion implanted MgO(1 0 0)

    NASA Astrophysics Data System (ADS)

    Fedorov, A. V.; van Huis, M. A.; van Veen, A.

    2002-05-01

    Ion implantation at elevated temperature, so-called hot implantation, was used to study nucleation and thermal stability of the defects. In this work, MgO(1 0 0) single crystal samples were implanted with 30 keV He ions at various implantation temperatures. The implantation doses ranged from 10 14 to 10 16 cm -2. The implantation introduced defects were subsequently studied by thermal helium desorption spectroscopy (THDS) and Doppler broadening positron beam analysis (PBA). The THDS study provides vital information on the kinetics of He release from the sample. PBA technique, being sensitive to the open volume defects, provides complementary information on cavity evolution. The THD study has shown that in most cases helium release is characterised by the activation energy of Q=4.7±0.5 eV with the maximum release temperature of Tmax=1830 K. By applying first order desorption model the pre-exponent factor is estimated as ν=4.3×10 11 s -1.

  5. Positronium formation in SiO2 films grown on Si substrates studied by monoenergetic positron beams

    NASA Astrophysics Data System (ADS)

    Uedono, A.; Wei, L.; Tanigawa, S.; Suzuki, R.; Ohgaki, H.; Mikado, T.; Kawano, T.; Ohji, Y.

    1994-04-01

    The annihilation characteristics of positrons in SiO2 films grown on Si substrates were studied by using monoenergetic positron beams. Doppler broadening profiles of the annihilation radiation and lifetime spectra of positrons were measured as a function of incident positron energy for SiO2 (166 nm)/Si specimens fabricated by thermal oxidation. From the measurements, it was found that about 90% of positrons implanted into the SiO2 film annihilate from positronium (Ps) states. This fact was due to the trapping of positrons by open-space defects and a resultant enhanced formation of Ps in such regions. For the SiO2 film grown at 650 °C, the lifetime of ortho-Ps was found to be shorter than that in the film grown at 1000 °C. This result suggests that the volume of open-space defects in the SiO2 film decreased with decreasing the growth rate of the SiO2 film.

  6. Investigation of membranous ventricular septal defect complicated with tricuspid regurgitation in ventricular septal defect occlusion

    PubMed Central

    LIU, SHU-PING; LI, LI; YAO, KE-CHUN; WANG, NA; WANG, JIAN-CHANG

    2013-01-01

    This study aimed to explore the mechanism of membranous ventricular septal defect complicated with tricuspid regurgitation and the significance of ventricular septal defect occlusion by echocardiography. A total of 43 patients with membranous ventricular septal defect complicated with tricuspid regurgitation were observed by echocardiography and the changes in length, area and volume of tricuspid regurgitation prior to and following ventricular septal defect occlusion were measured. There were four different mechanisms of membranous ventricular septal defect complicated with tricuspid regurgitation. The various indices of tricuspid regurgitation volume were significantly reduced following occlusion. Ventricular septal defect occlusion significantly reduces tricuspid regurgitation volume complicated with membranous ventricular septal defect and echocardiography is an ideal method to detect these changes. PMID:23404058

  7. Topological defects in open string field theory

    NASA Astrophysics Data System (ADS)

    Kojita, Toshiko; Maccaferri, Carlo; Masuda, Toru; Schnabl, Martin

    2018-04-01

    We show how conformal field theory topological defects can relate solutions of open string field theory for different boundary conditions. To this end we generalize the results of Graham and Watts to include the action of defects on boundary condition changing fields. Special care is devoted to the general case when nontrivial multiplicities arise upon defect action. Surprisingly the fusion algebra of defects is realized on open string fields only up to a (star algebra) isomorphism.

  8. [Comparative study on graft of autogeneic iliac bone and tissue engineered bone].

    PubMed

    Shen, Bing; Xie, Fu-lin; Xie, Qing-fang

    2002-11-01

    To compare the clinical results of repairing bone defect of limbs with tissue engineering technique and with autogeneic iliac bone graft. From July 1999 to September 2001, 52 cases of bone fracture were randomly divided into two groups (group A and B). Open reduction and internal fixation were performed in all cases as routine operation technique. Autogeneic iliac bone was implanted in group A, while tissue engineered bone was implanted in group B. Routine postoperative treatment in orthopedic surgery was taken. The operation time, bleeding volume, wound healing and drainage volume were compared. The bone union was observed by the X-ray 1, 2, 3, and 5 months after operation. The sex, age and disease type had no obvious difference between groups A and B. all the wounds healed with first intention. The swelling degree of wound and drainage volume had no obvious difference. The operation time in group A was longer than that in group B (25 minutes on average) and bleeding volume in group A was larger than that in group B (150 ml on average). Bone union completed within 3 to 7 months in both groups. But there were 2 cases of delayed union in group A and 1 case in group B. Repair of bone defect with tissue engineered bone has as good clinical results as that with autogeneic iliac bone graft. In aspect of operation time and bleeding volume, tissue engineered bone graft is superior to autogeneic iliac bone.

  9. Positron annihilation spectroscopy of vacancy-related defects in CdTe:Cl and CdZnTe:Ge at different stoichiometry deviations

    PubMed Central

    Šedivý, L.; Čížek, J.; Belas, E.; Grill, R.; Melikhova, O.

    2016-01-01

    Positron annihilation spectroscopy (PAS) was used to examine the effect of defined Cd-rich and Te-rich annealing on point defects in Cl-doped CdTe and Ge-doped CdZnTe semi-insulating single crystals. The as-grown crystals contain open-volume defects connected with Cd vacancies . It was found that the Cd vacancies agglomerate into clusters coupled with Cl in CdTe:Cl, and in CdZnTe:Ge they are coupled with Ge donors. While annealing in Cd pressure reduces of the density, subsequent annealing in Te pressure restores . The CdTe:Cl contains negatively-charged shallow traps interpreted as Rydberg states of A-centres and representing the major positron trapping sites at low temperature. Positrons confined in the shallow traps exhibit lifetime, which is shorter than the CdTe bulk lifetime. Interpretation of the PAS data was successfully combined with electrical resistivity, Hall effect measurements and chemical analysis, and allowed us to determine the principal point defect densities. PMID:26860684

  10. Cleft closure and undersizing annuloplasty improve mitral repair in atrioventricular canal defects

    PubMed Central

    Padala, Muralidhar; Vasilyev, Nikolay V.; Owen, James W.; Jimenez, Jorge H.; Dasi, Lakshmi P.; del Nido, Pedro J.; Yoganathan, Ajit P.

    2009-01-01

    Objective Reoperation rates to correct left atrioventricular valve regurgitation after primary repair of atrioventricular canal defects remain relatively high. The causes of valvular regurgitation are likely multifactorial, and simple cleft closure is often insufficient to prevent recurrence. Methods To elucidate the mechanisms leading to regurgitation, we conducted hemodynamic studies using isolated native mitral valves. Anatomy of these valves was altered to mimic atrioventricular canal type valves and studied under pediatric hemodynamic conditions. The impact of subvalvular geometry, cleft closure, annular dilatation, and annular undersizing on regurgitation were investigated. Results Papillary muscle position did not have a significant effect on regurgitation. Cleft closure had a significant impact on valvular competence, with reduction in regurgitation volume with increased cleft closure. Regurgitation volume decreased from 12.5 ± 2.4 mL/beat for an open cleft to 4.9 ± 1.9 mL/beat for a partially closed cleft and to 1.4 ± 1.6 mL/beat when the cleft was completely closed. Annular dilatation had a significant impact on regurgitation even after cleft closure. A 40% increase in annular size increased regurgitation by 59% for a partially closed cleft and by 84% for a fully closed cleft. Reducing the annular size by 20% from the physiologic level decreased the regurgitation volume by 12% for a fully open cleft and by 58% for the partially closed cleft case. Conclusions Annular dilatation after primary repair has a potentially significant role in the recurrence of atrioventricular valve regurgitation. Reducing the annular size and restricting dilatation as an adjunct to cleft closure is a promising surgical approach in such valve anatomies. PMID:19026810

  11. Application of Hydrogel in Reconstruction Surgery: Hydrogel/Fat Graft Complex Filler for Volume Reconstruction in Critical Sized Muscle Defects.

    PubMed

    Lui, Y F; Ip, W Y

    2016-01-01

    Autogenic fat graft usually suffers from degeneration and volume shrinkage in volume reconstruction applications. How to maintain graft viability and graft volume is an essential consideration in reconstruction therapies. In this presented investigation, a new fat graft transplantation method was developed aiming to improve long term graft viability and volume reconstruction effect by incorporation of hydrogel. The harvested fat graft is dissociated into small fragments and incorporated into a collagen based hydrogel to form a hydrogel/fat graft complex for volume reconstruction purpose. In vitro results indicate that the collagen based hydrogel can significantly improve the survivability of cells inside isolated graft. In a 6-month investigation on artificial created defect model, this hydrogel/fat graft complex filler has demonstrated the ability of promoting fat pad formation inside the targeted defect area. The newly generated fat pad can cover the whole defect and restore its original dimension in 6-month time point. Compared to simple fat transplantation, this hydrogel/fat graft complex system provides much improvement on long term volume restoration effect against degeneration and volume shrinkage. One notable effect is that there is continuous proliferation of adipose tissue throughout the 6-month period. In summary, the hydrogel/fat graft system presented in this investigation demonstrated a better and more significant effect on volume reconstruction in large sized volume defect than simple fat transplantation.

  12. Microstructure and magnetic behavior studies of processing-controlled and composition-modified Fe-Ni and Mn-Al alloys

    NASA Astrophysics Data System (ADS)

    Geng, Yunlong

    L10-type (Space group P4/mmm) magnetic compounds, including FeNi and MnAl, possess promising technical magnetic properties of both high magnetization and large magnetocrystalline anisotropy energy, and thus offer potential in replacing rare earth permanent magnets in some applications. In equiatomic Fe-Ni, the disorder-order transformation from fcc structure to the L10 structure is a diffusional transformation, but is inhibited by the low ordering temperature. The transformation could be enhanced through the creation of vacancies. Thus, mechanical alloying was employed to generate more open-volume defects. A decrease in grain size and concomitant increase in grain boundary area resulted from the mechanical alloying, while an initial increase in internal strain (manifested through an increase in dislocation density) was followed by a subsequent decrease with further alloying. However, a decrease in the net defect concentration was determined by Doppler broadening positron annihilation spectroscopy, as open volume defects utilized dislocations and grain boundaries as sinks. An alloy, Fe32Ni52Zr3B13, formed an amorphous structure after rapid solidification, with a higher defect concentration than crystalline materials. Mechanical milling was utilized in an attempt to generate even more defects. However, it was observed that Fe32Ni52Zr3B13 underwent crystallization during the milling process, which appears to be related to enhanced vacancy-type defect concentrations allowing growth of pre-existing Fe(Ni) nuclei. The milling and enhanced vacancy concentration also de-stabilizes the glass, leading to decreased crystallization temperatures, and ultimately leading to complete crystallization. In Mn-Al, the L10 structure forms from the parent hcp phase. However, this phase is slightly hyperstoichiometric relative to Mn, and the excess Mn occupies Al sites and couples antiparallel to the other Mn atoms. In this study, the Zr substituted preferentially for the Mn atoms in the Al layer, resulting in an increase in saturation magnetization, from 115 emu/g in the alloys without Zr to 128 emu/g in Mn53Al43C 3Zr1. To further improve the coercivity in Mn53Al 43C3Zr1, microstructure modification was achieved through the addition of excessive C and through surfactant-assisted mechanical milling. Enhancement in coercivity was accomplished through the microstructure modification, however, the loss of saturation magnetization was observed due to the formation of other equilibrium phases, including epsilon, beta-Mn and ZrO.

  13. Masticatory function and oral health-related quality of life in patients after partial maxillectomies with closed or open defects.

    PubMed

    Said, Mohamed M; Otomaru, Takafumi; Yeerken, Yesiboli; Taniguchi, Hisashi

    2017-07-01

    The healing pattern after surgical resection of tumors of the oral cavity involving the maxilla may vary from one patient to another. The result may be open communication between the oral and nasal cavities (open defect) or complete oronasal separation after healing of the defect area (closed defect). The purpose of this clinical study was to compare masticatory function and oral health-related quality of life (OHRQoL) between patients with closed and open defects who had undergone a partial maxillectomy and were wearing dentomaxillary prostheses. Thirty-eight participants who had undergone a partial maxillectomy and who were wearing dentomaxillary prostheses were enrolled between September 2014 and April 2016. Participants were assigned to 2 groups according to the type of defect after healing: 19 participants had a closed defect, and 19 participants had an open defect. Masticatory function was evaluated objectively and subjectively. The objective measurement was food-mixing ability, which was assessed using color-changeable chewing gum. The subjective measurement was perceived mastication ability, rated as a masticatory score based on the patient's responses to a 35-item food intake questionnaire. OHRQoL was assessed using the Geriatric Oral Health Assessment Index (GOHAI). The GOHAI questionnaire consists of 12 items reflecting 3 hypothesized domains of the impact of oral disease: physical function, psychosocial function, and pain or discomfort. Differences in the scores obtained by the 3 measurements were compared between the 2 groups, using the Wilcoxon rank-sum test (α=.05). No significant differences were seen between the 2 groups in objective mixing ability, subjective masticatory score, or GOHAI (P>.05). Regarding the GOHAI physical function domain, only the swallowing item was significantly lower (P=.025) in participants with an open defect than in participants with a closed defect. Regarding the GOHAI psychological function domain, the item related to patients' psychological worries or concerns about their teeth, gingival tissue, or dentures was significantly lower (P=.045) in patients with an open defect than in those with a closed defect. Other items related to physical function, psychological function, and pain or discomfort were not significantly different (P>.05) between the 2 groups. The closed or open defect in patients who had undergone a partial maxillectomy may not influence patients' masticatory function and overall OHRQoL if they have adequate prosthetic rehabilitation. However, special consideration should be given to patients with an open defect with regard to swallowing function and psychological concerns in order to improve their OHRQoL. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. EUV mask defect inspection and defect review strategies for EUV pilot line and high volume manufacturing

    NASA Astrophysics Data System (ADS)

    Chan, Y. David; Rastegar, Abbas; Yun, Henry; Putna, E. Steve; Wurm, Stefan

    2010-04-01

    Reducing mask blank and patterned mask defects is the number one challenge for extreme ultraviolet lithography. If the industry succeeds in reducing mask blank defects at the required rate of 10X every year for the next 2-3 years to meet high volume manufacturing defect requirements, new inspection and review tool capabilities will soon be needed to support this goal. This paper outlines the defect inspection and review tool technical requirements and suggests development plans to achieve pilot line readiness in 2011/12 and high volume manufacturing readiness in 2013. The technical specifications, tooling scenarios, and development plans were produced by a SEMATECH-led technical working group with broad industry participation from material suppliers, tool suppliers, mask houses, integrated device manufacturers, and consortia. The paper summarizes this technical working group's assessment of existing blank and mask inspection/review infrastructure capabilities to support pilot line introduction and outlines infrastructure development requirements and tooling strategies to support high volume manufacturing.

  15. Cortical bone thickening in Type A posterior atlas arch defects: experimental report.

    PubMed

    Sanchis-Gimeno, Juan A; Llido, Susanna; Guede, David; Martinez-Soriano, Francisco; Ramon Caeiro, Jose; Blanco-Perez, Esther

    2017-03-01

    To date, no information about the cortical bone microstructural properties in atlas vertebrae with posterior arch defects has been reported. To test if there is an increased cortical bone thickening in atlases with Type A posterior atlas arch defects in an experimental model. Micro-computed tomography (CT) study on cadaveric atlas vertebrae. We analyzed the cortical bone thickness, the cortical volume, and the medullary volume (SkyScan 1172 Bruker micro-CT NV, Kontich, Belgium) in cadaveric dry vertebrae with a Type A atlas arch defect and normal control vertebrae. The micro-CT study revealed significant differences in cortical bone thickness (p=.005), cortical volume (p=.003), and medullary volume (p=.009) values between the normal and the Type A vertebrae. Type A congenital atlas arch defects present a cortical bone thickening that may play a protective role against atlas fractures. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. An investigation of hydrogenized amorphous Si structures with Doppler broadening positron annihilation techniques

    NASA Astrophysics Data System (ADS)

    Petkov, M. P.; Marek, T.; Asoka-Kumar, P.; Lynn, K. G.; Crandall, R. S.; Mahan, A. H.

    1998-07-01

    In this letter, we examine the feasibility of applying positron annihilation spectroscopy to the study of hydrogenized amorphous silicon (a-Si:H)-based structures produced by chemical vapor deposition techniques. The positron probe, sensitive to open volume formations, is used to characterize neutral and negatively charged silicon dangling bonds, typical for undoped and n-doped a-Si:H, respectively. Using depth profiling along the growth direction a difference was observed in the electronic environment of these defects, which enables their identification in a p-i-n device.

  17. Effect of Casting Defect on Mechanical Properties of 17-4PH Stainless Steel

    NASA Astrophysics Data System (ADS)

    Kim, Jong-Yup; Lee, Joon-Hyun; Nahm, Seung-Hoon

    Damage and integrity evaluation techniques should be developed steadily in order to ensure the reliability and the economic efficiency of gas turbine engines. Casting defects may exist in most casting components of gas turbine engines, and the defects could give serious effect on mechanical properties and fracture toughness. Therefore, it is very important to understand the effect of casting defects on the above properties in order to predict the safety and life of components. In this study, specimens with internal casting defects, made from 17-4PH stainless steel, were prepared and evaluated and characterized based on the volume fraction of defects. The relation between mechanical properties such as tensile, low cycle fatigue and fracture toughness and volume fraction of defect has been investigated. As a result of the analysis, the mechanical properties of 17-4PH decreased as the defect volume fraction increased with very good linearity. The mechanical properties also showed an inversely proportional relationship to electrical resistivity.

  18. Defect Detection in Superconducting Radiofrequency Cavity Surface Using C + + and OpenCV

    NASA Astrophysics Data System (ADS)

    Oswald, Samantha; Thomas Jefferson National Accelerator Facility Collaboration

    2014-03-01

    Thomas Jefferson National Accelerator Facility (TJNAF) uses superconducting radiofrequency (SRF) cavities to accelerate an electron beam. If theses cavities have a small particle or defect, it can degrade the performance of the cavity. The problem at hand is inspecting the cavity for defects, little bubbles of niobium on the surface of the cavity. Thousands of pictures have to be taken of a single cavity and then looked through to see how many defects were found. A C + + program with Open Source Computer Vision (OpenCV) was constructed to reduce the number of hours searching through the images and finds all the defects. Using this code, the SRF group is now able to use the code to identify defects in on-going tests of SRF cavities. Real time detection is the next step so that instead of taking pictures when looking at the cavity, the camera will detect all the defects.

  19. The effect of a defective BSF layer on solar cell open circuit voltage. [Back Surface Field

    NASA Technical Reports Server (NTRS)

    Weizer, V. G.

    1985-01-01

    A straightforward analysis of special limiting cases has permitted the determination of the range of possible open circuit voltage losses due to a defective BSF (back surface field) layer. An important result of the analysis is the finding that it is possible to have a fully effective BSF region, regardless of the spatial distribution of the defective areas, as long as the total defective area is reduced below certain limits. Distributed defects were found to be much more harmful than lumped defects.

  20. Vacancy-type defects in TiO2/SiO2/SiC dielectric stacks

    NASA Astrophysics Data System (ADS)

    Coleman, P. G.; Burrows, C. P.; Mahapatra, R.; Wright, N. G.

    2007-07-01

    Open-volume (vacancy-type) point defects have been observed in ˜80-nm-thick titanium dioxide films grown on silicon dioxide/4H silicon carbide substrates as stacks with high dielectric constant for power device applications, using variable-energy positron annihilation spectroscopy. The concentration of vacancies decreases as the titanium dioxide growth temperature is increased in the range from 700to1000°C, whereas grain boundaries form in the polycrystalline material at the highest growth temperatures. It is proposed that the optimal electrical performance for films grown at 800°C reflects a balance between decreasing vacancy concentration and increasing grain boundary formation. The concentration of vacancies at the silicon dioxide/silicon carbide interface appears to saturate after 2.5h oxidation at 1150°C. A supplementary result suggests that the quality of the 10-μm-thick deposited silicon carbide epilayer is compromised at depths of about 2μm and beyond, possibly by the migration of impurities and/or other defects from the standard-grade highly doped 4H silicon carbide wafer beneath the epilayer during oxidation.

  1. Unsound defect volume in hardwood pallet cants

    Treesearch

    Philip Araman; Matt Winn; Firoz Kabir; Xavier Torcheux; Guillaume Loizeaud

    2003-01-01

    A study was conducted to determine the percentage of unsound defect volume to sound/clear wood in pallet cants at selected sawmills in Virginia and West Virginia. Splits,wane, shake, holes, decay, unsound knots, bark pockets, and mechanical defects were all considered to be unsound. Data were collected from seven Appalachian area sawmills for four hardwood species: red...

  2. Methods for Measuring Lung Volumes: Is There a Better One?

    PubMed

    Tantucci, Claudio; Bottone, Damiano; Borghesi, Andrea; Guerini, Michele; Quadri, Federico; Pini, Laura

    2016-01-01

    Accurate measurement of lung volumes is of paramount importance to establish the presence of ventilatory defects and give insights for diagnostic and/or therapeutic purposes. It was the aim of this study to measure lung volumes in subjects with respiratory disorders and in normal controls by 3 different techniques (plethysmographic, dilutional and radiographic methods), in an attempt to clarify the role of each of them in performing such a task, without any presumptive 'a priori' superiority of one method above others. Patients andMethods: In different groups of subjects with obstructive and restrictive ventilatory defects and in a normal control group, total lung capacity, functional residual capacity (FRC) and residual volume were measured by body plethysmography, multi-breath helium (He) dilution and radiographic CT scan method with spirometric gating. The 3 methods gave comparable results in normal subjects and in patients with a restrictive defect. In patients with an obstructive defect, CT scan and plethysmography showed similar lung volumes, while on average significantly lower lung volumes were obtained with the He dilution technique. Taking into account that the He dilution technique does primarily measure FRC during tidal breathing, our data suggest that in some patients with an obstructive defect, a number of small airways can be functionally closed at end-expiratory lung volume, preventing He to reach the lung regions subserved by these airways. In all circumstances, both CT scan with spirometric gating and plethysmographic methods provide similar values of lung volumes. In contrast, the He dilution method can measure lower lung volumes in some patients with chronic airflow obstruction. © 2016 S. Karger AG, Basel.

  3. An open-architecture approach to defect analysis software for mask inspection systems

    NASA Astrophysics Data System (ADS)

    Pereira, Mark; Pai, Ravi R.; Reddy, Murali Mohan; Krishna, Ravi M.

    2009-04-01

    Industry data suggests that Mask Inspection represents the second biggest component of Mask Cost and Mask Turn Around Time (TAT). Ever decreasing defect size targets lead to more sensitive mask inspection across the chip, thus generating too many defects. Hence, more operator time is being spent in analyzing and disposition of defects. Also, the fact that multiple Mask Inspection Systems and Defect Analysis strategies would typically be in use in a Mask Shop or a Wafer Foundry further complicates the situation. In this scenario, there is a need for a versatile, user friendly and extensible Defect Analysis software that reduces operator analysis time and enables correct classification and disposition of mask defects by providing intuitive visual and analysis aids. We propose a new vendor-neutral defect analysis software, NxDAT, based on an open architecture. The open architecture of NxDAT makes it easily extensible to support defect analysis for mask inspection systems from different vendors. The capability to load results from mask inspection systems from different vendors either directly or through a common interface enables the functionality of establishing correlation between inspections carried out by mask inspection systems from different vendors. This capability of NxDAT enhances the effectiveness of defect analysis as it directly addresses the real-life scenario where multiple types of mask inspection systems from different vendors co-exist in mask shops or wafer foundries. The open architecture also potentially enables loading wafer inspection results as well as loading data from other related tools such as Review Tools, Repair Tools, CD-SEM tools etc, and correlating them with the corresponding mask inspection results. A unique concept of Plug-In interface to NxDAT further enhances the openness of the architecture of NxDAT by enabling end-users to add their own proprietary defect analysis and image processing algorithms. The plug-in interface makes it possible for the end-users to make use of their collected knowledge through the years of experience in mask inspection process by encapsulating the knowledge into software utilities and plugging them into NxDAT. The plug-in interface is designed with the intent of enabling the pro-active mask defect analysis teams to build competitive differentiation into their defect analysis process while protecting their knowledge internally within their company. By providing interface with all major standard layout and mask data formats, NxDAT enables correlation of defect data on reticles with design and mask databases, further extending the effectiveness of defect analysis for D2DB inspection. NxDAT also includes many other advanced features for easy and fast navigation, visual display of defects, defect selection, multi-tier classification, defect clustering and gridding, sophisticated CD and contact measurement analysis, repeatability analysis such as adder analysis, defect trend, capture rate etc.

  4. Torque test measurement in segmental bone defects using porous calcium phosphate cement implants.

    PubMed

    Kroese-Deutman, Henriette C; Wolke, Joop G C; Spauwen, Paul H M; Jansen, John A

    2010-10-01

    This study was performed to assess the bone healing supporting characteristics of porous calcium phosphate (Ca-P) cement when implanted in a rabbit segmental defect model as well as to determine the reliability of torque testing as a method to verify bone healing. The middiaphyseal radius was chosen as the area to create bilaterally increasing defect sizes (5, 10, and 15 mm), which were either filled with porous Ca-P cement or left open as a control. After 12 weeks of implantation, torque test measurements as well as histological and radiographic evaluation were performed. In two of the open 15 mm control defects, bone bridging was visible at the radiographic and histological evaluation. Bone was observed to be present in all porous Ca-P cement implants (5, 10, and 15 mm defects) after 12 weeks. No significant differences in torque measurements were observed between the 5 and 10 mm filled and open control defects using a t-test. In addition, the mechanical strength of all operated specimens was similar compared with nonoperated bone samples. The torsion data for the 15 mm open defect appeared to be lower compared with the filled 15 mm defect, but no significant difference could be proven. Within the limitation of the study design, porous Ca-P cement implants demonstrated osteoconductive properties and confirmed to be a suitable scaffold material in a weight-bearing situation. Further, the used torque testing method was found to be unreliable for testing the mechanical properties of the healed bone defect.

  5. Lattice constant in nonstoichiometric uranium dioxide from first principles

    NASA Astrophysics Data System (ADS)

    Bruneval, Fabien; Freyss, Michel; Crocombette, Jean-Paul

    2018-02-01

    Nonstoichiometric uranium dioxide experiences a shrinkage of its lattice constant with increasing oxygen content, in both the hypostoichiometric and the hyperstoichiometric regimes. Based on first-principles calculations within the density functional theory (DFT)+U approximation, we have developed a point defect model that accounts for the volume of relaxation of the most significant intrinsic defects of UO2. Our point defect model takes special care of the treatment of the charged defects in the equilibration of the model and in the determination of reliable defect volumes of formation. In the hypostoichiometric regime, the oxygen vacancies are dominant and explain the lattice constant variation with their surprisingly positive volume of relaxation. In the hyperstoichiometric regime, the uranium vacancies are predicted to be the dominating defect,in contradiction with experimental observations. However, disregarding uranium vacancies allows us to recover a good match for the lattice-constant variation as a function of stoichiometry. This can be considered a clue that the uranium vacancies are indeed absent in UO2 +x, possibly due to the very slow diffusion of uranium.

  6. Staebler-Wronski Effect Studied with Positrons

    NASA Astrophysics Data System (ADS)

    Gessmann, Thomas; Weber, Marc H.; Lynn, Kelvin G.; Crandall, Richard S.; Yang, Jeffrey; Guha, Subhendu

    2001-03-01

    Positrons implanted into condensed matter may localize in open volume defects. The energies of gamma-rays emitted after annihilation of positrons with electrons are Doppler-shifted corresponding to the electron momenta at the annihilation site. We used depth-dependent positron annihilation spectroscopy [1] to investigate layers of hydrogenated amorphous-silicon (a-Si:H) deposited by plasma-enhanced chemical-vapor deposition (PECVD). The positron data are interpreted in terms of a dimensionless S-parameter referred to crystalline silicon. The magnitude of S is a measure for the size and concentration of open volume defects acting as trapping sites for positrons. In samples subjected to different hydrogen dilutions during film growth the S-parameter indicates a transition from the amorphous to the microcrystalline structure for large hydrogen-to-disilane ratios. In layers (thickness 250 nm) grown on stainless steel substrates [2] we find that hydrogen dilution results in reduced S-values (1.0127+-0.0007) compared to non-hydrogen diluted samples (1.0316+-0.0007) at room temperature. The S parameters in both hydrogen diluted and non-hydrogen diluted are the lowest ever measured attesting to the dense nature of the material. Previous studies [2] showed superior solar cell characteristics of these layers when grown with hydrogen-to-disilane ratios near the onset of microcrystallinity. Following one-sun light exposure for 400 hr a further decrease in S is observed in both normal and hydrogen diluted samples suggesting a change in the defect associated with light soaking. Two hours annealing at 160 C in air restores the original S-parameter. This behavior was observed for the first time by positron annihilation spectroscopy and may be interpreted as evidence of large scale metastable changes associated with the Staebler-Wronski effect [3]. [1] P.J. Schultz and K.G. Lynn, Rev. Mod. Phys. 60, 701 (1988). [2] S. Guha, J. Yang, D. L. Williamson, Y. Lubianker, J. D. Cohen, A. H. Mahan Appl. Phys. Lett. 74, 1860 (1999). [3] D.L. Staebler and C.R. Wronski, Appl. Phys. Lett. 31, 292 (1977).

  7. Defect tolerance in resistor-logic demultiplexers for nanoelectronics.

    PubMed

    Kuekes, Philip J; Robinett, Warren; Williams, R Stanley

    2006-05-28

    Since defect rates are expected to be high in nanocircuitry, we analyse the performance of resistor-based demultiplexers in the presence of defects. The defects observed to occur in fabricated nanoscale crossbars are stuck-open, stuck-closed, stuck-short, broken-wire, and adjacent-wire-short defects. We analyse the distribution of voltages on the nanowire output lines of a resistor-logic demultiplexer, based on an arbitrary constant-weight code, when defects occur. These analyses show that resistor-logic demultiplexers can tolerate small numbers of stuck-closed, stuck-open, and broken-wire defects on individual nanowires, at the cost of some degradation in the circuit's worst-case voltage margin. For stuck-short and adjacent-wire-short defects, and for nanowires with too many defects of the other types, the demultiplexer can still achieve error-free performance, but with a smaller set of output lines. This design thus has two layers of defect tolerance: the coding layer improves the yield of usable output lines, and an avoidance layer guarantees that error-free performance is achieved.

  8. Multilayer porous UHMWPE scaffolds for bone defects replacement.

    PubMed

    Maksimkin, A V; Senatov, F S; Anisimova, N Yu; Kiselevskiy, M V; Zalepugin, D Yu; Chernyshova, I V; Tilkunova, N A; Kaloshkin, S D

    2017-04-01

    Reconstruction of the structural integrity of the damaged bone tissue is an urgent problem. UHMWPE may be potentially used for the manufacture of porous implants simulating as closely as possible the porous cancellous bone tissue. But the extremely high molecular weight of the polymer does not allow using traditional methods of foaming. Porous and multilayer UHMWPE scaffolds with nonporous bulk layer and porous layer that mimics cancellous bone architecture were obtained by solid-state mixing, thermopressing and washing in subcritical water. Structural and mechanical properties of the samples were studied. Porous UHMWPE samples were also studied in vitro and in vivo. The pores of UHMWPE scaffold are open and interconnected. Volume porosity of the obtained samples was 79±2%; the pore size range was 80-700μm. Strong connection of the two layers in multilayer UHMWPE scaffolds was observed with decreased number of fusion defects. Functionality of implants based on multilayer UHMWPE scaffolds is provided by the fixation of scaffolds in the bone defect through ingrowths of the connective tissue into the pores, which ensures the maintenance of the animals' mobility. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Defect Creation by Linker Fragmentation in Metal-Organic Frameworks and Its Effects on Gas Uptake Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barin, G; Krungleviciute, V; Gutov, O

    2014-07-07

    We successfully demonstrate an approach based on linker fragmentation to create defects and tune the pore volumes and surface areas of two metal-organic frameworks, NU-125 and HKUST-1, both of which feature copper paddlewheel nodes. Depending on the linker fragment composition, the defect can be either a vacant site or a functional group that the original linker does not have. In the first case, we show that both surface area and pore volume increase, while in the second case they decrease. The effect of defects on the high-pressure gas uptake is also studied over a large temperature and pressure range formore » different gases. We found that despite an increase in pore volume and surface area in structures with vacant sites, the absolute adsorption for methane decreases for HKUST-1 and slightly increases for NU-125. However, the working capacity (deliverable amount between 65 and 5 bar) in both cases remains similar to parent frameworks due to lower uptakes at low pressures. In the case of NU-125, the effect of defects became more pronounced at lower temperatures, reflecting the greater surface areas and pore volumes of the altered forms.« less

  10. Open heart surgery in Nigeria; a work in progress.

    PubMed

    Falase, Bode; Sanusi, Michael; Majekodunmi, Adetinuwe; Animasahun, Barakat; Ajose, Ifeoluwa; Idowu, Ariyo; Oke, Adewale

    2013-01-12

    There has been limited success in establishing Open Heart Surgery programmes in Nigeria despite the high prevalence of structural heart disease and the large number of Nigerian patients that travel abroad for Open Heart Surgery. The challenges and constraints to the development of Open Heart Surgery in Nigeria need to be identified and overcome. The aim of this study is to review the experience with Open Heart Surgery at the Lagos State University Teaching Hospital and highlight the challenges encountered in developing this programme. This is a retrospective study of patients that underwent Open Heart Surgery in our institution. The source of data was a prospectively maintained database. Extracted data included patient demographics, indication for surgery, euroscore, cardiopulmonary bypass time, cross clamp time, complications and patient outcome. 51 Open Heart Surgery procedures were done between August 2004 and December 2011. There were 21 males and 30 females. Mean age was 29 ± 15.6 years. The mean euroscore was 3.8 ± 2.1. The procedures done were Mitral Valve Replacement in 15 patients (29.4%), Atrial Septal Defect Repair in 14 patients (27.5%), Ventricular Septal Defect Repair in 8 patients (15.7%), Aortic Valve Replacement in 5 patients (9.8%), excision of Left Atrial Myxoma in 2 patients (3.9%), Coronary Artery Bypass Grafting in 2 patients (3.9%), Bidirectional Glenn Shunts in 2 patients (3.9%), Tetralogy of Fallot repair in 2 patients (3.9%) and Mitral Valve Repair in 1 patient (2%). There were 9 mortalities (17.6%) in this series. Challenges encountered included the low volume of cases done, an unstable working environment, limited number of trained staff, difficulty in obtaining laboratory support, limited financial support and difficulty in moving away from the Cardiac Mission Model. The Open Heart Surgery program in our institution is still being developed but the identified challenges need to be overcome if this program is to be sustained. Similar challenges will need to be overcome by other cardiac stakeholders if other OHS programs are to be developed and sustained in Nigeria.

  11. Computational modelling of ovine critical-sized tibial defects with implanted scaffolds and prediction of the safety of fixator removal.

    PubMed

    Doyle, Heather; Lohfeld, Stefan; Dürselen, Lutz; McHugh, Peter

    2015-04-01

    Computational model geometries of tibial defects with two types of implanted tissue engineering scaffolds, β-tricalcium phosphate (β-TCP) and poly-ε-caprolactone (PCL)/β-TCP, are constructed from µ-CT scan images of the real in vivo defects. Simulations of each defect under four-point bending and under simulated in vivo axial compressive loading are performed. The mechanical stability of each defect is analysed using stress distribution analysis. The results of this analysis highlights the influence of callus volume, and both scaffold volume and stiffness, on the load-bearing abilities of these defects. Clinically-used image-based methods to predict the safety of removing external fixation are evaluated for each defect. Comparison of these measures with the results of computational analyses indicates that care must be taken in the interpretation of these measures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Sulfamethoxazole/Trimethoprim (Bactrim or Septra) and Pregnancy

    MedlinePlus

    ... defects, neural tube defects (opening in the spine), cleft lip or palate (lip or roof of mouth do not form correctly), and urinary tract defects. Trimethoprim might decrease the ... bifida, oral clefts and heart defects. It is recommended that pregnant ...

  13. The investigation of the lateral interaction effect's on traffic flow behavior under open boundaries

    NASA Astrophysics Data System (ADS)

    Bouadi, M.; Jetto, K.; Benyoussef, A.; El Kenz, A.

    2017-11-01

    In this paper, an open boundaries traffic flow system is studied by taking into account the lateral interaction with spatial defects. For a random defects distribution, if the vehicles velocities are weakly correlated, the traffic phases can be predicted by considering the corresponding inflow and outflow functions. Conversely, if the vehicles velocities are strongly correlated, a phase segregation appears inside the system's bulk which induces the maximum current appearance. Such velocity correlation depends mainly on the defects densities and the probabilities of lateral deceleration. However, for a compact defects distribution, the traffic phases are predictable by using the inflow in the system beginning, the inflow entering the defects zone and the outflow function.

  14. The associations between parity, other reproductive factors and cartilage in women aged 50-80 years.

    PubMed

    Wei, S; Venn, A; Ding, C; Martel-Pelletier, J; Pelletier, J-P; Abram, F; Cicuttini, F; Jones, G

    2011-11-01

    Sex hormones and reproductive factors may be important for osteoarthritis (OA). The aim of this study was to describe the associations of parity, use of hormone replacement therapy (HRT) and oral contraceptives (OCs) with cartilage volume, cartilage defects and radiographic OA in a population-based sample of older women. Cross-sectional study of 489 women aged 50-80 years. Parity, use of HRT and OC was assessed by questionnaire; knee cartilage volume and defects by magnetic resonance imaging and knee joint space narrowing (JSN) and osteophytes by X-ray. Parity was associated with a deficit in total knee cartilage volume [adjusted β=-0.69 ml, 95% confidence interval (CI) -1.34, -0.04]. Increasing parity was associated with decreasing cartilage volume in both the tibial compartment and total knee (both P trend <0.05). Parity was also associated with greater cartilage defects in the patella compartment [adjusted odds ratio (OR)=2.87, 95% CI=1.39, 5.93] but not other sites. There was a consistent but non-significant increase in knee JSN (OR=2.78, 95% CI=0.75, 10.31) and osteophytes (OR=1.69, 95% CI=0.59, 4.82) for parous women. Use of HRT and/or OC was not associated with cartilage volume, cartilage defects or radiographic change. Parity (but not use of HRT or OC) is independently associated with lower cartilage volume primarily in the tibial compartment and higher cartilage defects in the patella compartment in this population-based sample of older women. Copyright © 2011 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  15. Volumetric Analysis of Alveolar Bone Defect Using Three-Dimensional-Printed Models Versus Computer-Aided Engineering.

    PubMed

    Du, Fengzhou; Li, Binghang; Yin, Ningbei; Cao, Yilin; Wang, Yongqian

    2017-03-01

    Knowing the volume of a graft is essential in repairing alveolar bone defects. This study investigates the 2 advanced preoperative volume measurement methods: three-dimensional (3D) printing and computer-aided engineering (CAE). Ten unilateral alveolar cleft patients were enrolled in this study. Their computed tomographic data were sent to 3D printing and CAE software. A simulated graft was used on the 3D-printed model, and the graft volume was measured by water displacement. The volume calculated by CAE software used mirror-reverses technique. The authors compared the actual volumes of the simulated grafts with the CAE software-derived volumes. The average volume of the simulated bone grafts by 3D-printed models was 1.52 mL, higher than the mean volume of 1.47 calculated by CAE software. The difference between the 2 volumes was from -0.18 to 0.42 mL. The paired Student t test showed no statistically significant difference between the volumes derived from the 2 methods. This study demonstrated that the mirror-reversed technique by CAE software is as accurate as the simulated operation on 3D-printed models in unilateral alveolar cleft patients. These findings further validate the use of 3D printing and CAE technique in alveolar defect repairing.

  16. Improvement of Railroad Roller Bearing Test Procedures & Development of Roller Bearing Diagnostic Techniques. Volume 1.

    DOT National Transportation Integrated Search

    1982-03-01

    Bearing defect data from 8,000 railroad roller bearings are analyzed to determine their defect modes and defect rate distributions. Cone bore growth, brinelling, and fatigue are identified as the predominant defect modes during the first 12 years of ...

  17. Defect identification in semiconductors with positron annihilation: experiment and theory

    NASA Astrophysics Data System (ADS)

    Tuomisto, Filip

    2015-03-01

    Positron annihilation spectroscopy is a very powerful technique for the detection, identification and quantification of vacancy-type defects in semiconductors. In the past decades, it has been used to reveal the relationship between opto-electronic properties and specific defects in a wide variety of materials - examples include parasitic yellow luminescence in GaN, dominant acceptor defects in ZnO and broad-band absorption causing brown coloration in natural diamond. In typical binary compound semiconductors, the selective sensitivity of the technique is rather strongly limited to cation vacancies that possess significant open volume and suitable charge (negative of neutral). On the other hand, oxygen vacancies in oxide semiconductors are a widely debated topic. The properties attributed to oxygen vacancies include the inherent n-type conduction, poor p-type dopability, coloration (absorption), deep level luminescence and non-radiative recombination, while the only direct experimental evidence of their existence has been obtained on the crystal surface. We will present recent advances in combining state-of-the-art positron annihilation experiments and ab initio computational approaches. The latter can be used to model both the positron lifetime and the electron-positron momentum distribution - quantities that can be directly compared with experimental results. We have applied these methods to study vacancy-type defects in III-nitride semiconductors (GaN, AlN, InN) and oxides such as ZnO, SnO2, In2O3andGa2O3. We will show that cation-vacancy-related defects are important compensating centers in all these materials when they are n-type. In addition, we will show that anion (N, O) vacancies can be detected when they appear as complexes with cation vacancies.

  18. Genetics Home Reference: congenital bile acid synthesis defect type 1

    MedlinePlus

    ... type 1 Congenital bile acid synthesis defect type 1 Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Congenital bile acid synthesis defect type 1 ...

  19. Evaluation of defect formation in helium irradiated Y2O3 doped W-Ti alloys by positron annihilation and nanoindentation

    NASA Astrophysics Data System (ADS)

    Richter, Asta; Anwand, Wolfgang; Chen, Chun-Liang; Böttger, Roman

    2017-10-01

    Helium implanted tungsten-titanium ODS alloys are investigated using positron annihilation spectroscopy and nanoindentation. Titanium reduces the brittleness of the tungsten alloy, which is manufactured by mechanical alloying. The addition of Y2O3 nanoparticles increases the mechanical properties at elevated temperature and enhances irradiation resistance. Helium ion implantation was applied to simulate irradiation effects on these materials. The irradiation was performed using a 500 kV He ion implanter at fluences around 5 × 1015 cm-2 for a series of samples both at room temperature and at 600 °C. The microstructure and mechanical properties of the pristine and irradiated W-Ti-ODS alloy are compared with respect to the titanium and Y2O3 content. Radiation damage is studied by positron annihilation spectroscopy analyzing the lifetime and the Doppler broadening. Three types of helium-vacancy defects were detected after helium irradiation in the W-Ti-ODS alloy: small defects with high helium-to-vacancy ratio (low S parameter) for room temperature irradiation, larger open volume defects with low helium-to-vacancy ratio (high S parameter) at the surface and He-vacancy complexes pinned at nanoparticles deeper in the material for implantation at 600 °C. Defect induced hardness was studied by nanoindentation. A drastic hardness increase is observed after He ion irradiation both for room temperature and elevated irradiation temperature of 600 °C. The Ti alloyed tungsten-ODS is more affected by the hardness increase after irradiation compared to the pure W-ODS alloy.

  20. Comparative Evaluation of Platelet-Rich Fibrin Biomaterial and Open Flap Debridement in the Treatment of Two and Three Wall Intrabony Defects

    PubMed Central

    Ajwani, Himanshu; Shetty, Sharath; Gopalakrishnan, Dharmarajan; Kathariya, Rahul; Kulloli, Anita; Dolas, R S; Pradeep, A R

    2015-01-01

    Background: Platelet-rich concentrates are the most widely used regenerative biomaterials. Stimulation and acceleration of soft and hard tissue healing are due to local and continuous delivery of growth factors and proteins, mimicking the needs of the physiological wound healing and reparative tissue processes. This article aims to evaluate the clinical efficacy of open flap debridement (OFD) with or without platelet-rich fibrin (PRF) in the treatment of intrabony defects. Materials and Methods: Twenty subjects with forty intrabony defects were treated with either autologous PRF with open-flap debridement (test, n = 20) or open-flap debridement alone (control, n = 20). Soft tissue parameters included: Plaque index, sulcus bleeding index, probing depth, relative attachment level and gingival marginal level (GML). The hard tissue parameters included-distances from: Cement enamel junction to the base of the defect (CEJ-BOD): Alveolar crest to the base of the defect (AC-BOD): And CEJ to AC. The parameters were recorded at baseline and at 9 months postoperatively calculated using standardized radiographs by image-analysis software. Results: Statistically significant (0.005*) intragroup improvements were seen with all the hard and soft parameters in both test and control groups, except for GML. Statistically significant improvements were seen with the mean defect fill (CEJ-BOD and AC-BOD) (P = 0.003*) when intergroup comparisons were made. Conclusions: Adjunctive use of PRF with OFD significantly improves defect fill when compared to OFD alone. PRF has consistently been showing regenerative potential; it is simple, easy and inexpensive biomaterial compared with bone grafts. PMID:25954068

  1. Evidence of the Zn vacancy acting as the dominant acceptor in n-type ZnO.

    PubMed

    Tuomisto, F; Ranki, V; Saarinen, K; Look, D C

    2003-11-14

    We have used positron annihilation spectroscopy to determine the nature and the concentrations of the open volume defects in as-grown and electron irradiated (E(el)=2 MeV, fluence 6 x 10(17) cm(-2)) ZnO samples. The Zn vacancies are identified at concentrations of [V(Zn)] approximately 2 x 10(15) cm(-3) in the as-grown material and [V(Zn)] approximately 2 x 10(16) cm(-3) in the irradiated ZnO. These concentrations are in very good agreement with the total acceptor density determined by temperature dependent Hall experiments. Thus, the Zn vacancies are dominant acceptors in both as-grown and irradiated ZnO.

  2. Epitaxial lateral overgrowth of InP on Si from nano-openings: Theoretical and experimental indication for defect filtering throughout the grown layer

    NASA Astrophysics Data System (ADS)

    Olsson, F.; Xie, M.; Lourdudoss, S.; Prieto, I.; Postigo, P. A.

    2008-11-01

    We present a model for the filtration of dislocations inside the seed window in epitaxial lateral overgrowth (ELO). We found that, when the additive effects of image and gliding forces exceed the defect line tension force, filtering can occur even in the openings. The model is applied to ELO of InP on Si where the opening size and the thermal stress arising due to the mask and the grown material are taken into account and analyzed. Further, we have also designed the mask patterns in net structures, where the tilting angles of the openings in the nets are chosen in order to take advantage of the filtering in the openings more effectively, and to minimize new defects due to coalescence in the ELO. Photoluminescence intensities of ELO InP on Si and on InP are compared and found to be in qualitative agreement with the model.

  3. Structural effects due to the incorporation of Ar atoms in the lattice of ZrO 2 thin films prepared by ion beam assisted deposition

    NASA Astrophysics Data System (ADS)

    Holgado, J. P.; Escobar Galindo, R.; van Veen, A.; Schut, H.; de Hosson, J. Th. M.; González-Elipe, A. R.

    2002-09-01

    Two sets of ZrO 2 thin films have been prepared at room temperature by ion beam induced chemical vapour deposition and subsequently annealed up to 1323 K. The two sets of samples have been prepared by using either O 2+ or mixtures of (O 2++Ar +) ions for the decomposition of a volatile metallorganic precursor of zirconium. The structure and microstructure of these two sets of samples have been determined by means of X-ray diffraction, Fourier transform infrared spectroscopy and positron beam analysis (PBA). The samples were very compact and dense and had a very low-surface roughness. After annealing in air at T⩾573 K both sets of films were transparent and showed similar refraction indexes. For the (O 2++Ar +)-ZrO 2 thin films it is shown by X-ray photoelectron spectroscopy and Rutherford back scattering that a certain amount of incorporated Ar (5-6 at.%) remains incorporated within the oxide lattice. No changes were detected in the amount of incorporated Ar even after annealing at T=773 K. For higher annealing temperatures ( T>1073 K), the amount of Ar starts to decrease, and at T=1223 K only residual amounts of Ar (<0.4%) remain within the lattice. It has been found that as far as Ar atoms remain incorporated within the ZrO 2 network, the (O 2+-Ar +)-ZrO 2 films present a cubic/tetragonal phase. When the amount of "embedded" Ar decreases, the crystalline phase reverts to monoclinic, the majority phase observed for the (O 2+)-ZrO 2 films after any annealing treatments. The microstructure of the films after different annealing treatments has been investigated by PBA. The presence of Ar ions and the initial amorphous state of the layers were detected by this technique. An increase of the open volume was observed after annealing up to 773 K in both sets of samples. For higher annealing temperatures the samples showed a progressive crystallisation resulting in a decrease of the open volume. During this sintering the samples without embedded Ar present a higher concentration of open volume defects. After the release of Ar occurs ( T⩾1223 K) both samples approach to a similar defect free state. The incorporation of Ar within the ZrO 2 thin film structure, is proposed as the main factor contributing to the stabilisation of the cubic/tetragonal phase of ZrO 2 at room temperature.

  4. Thermal degradation of InP in open tube processing: deep-level photoluminescence

    NASA Astrophysics Data System (ADS)

    Banerjee, S.; Srivastava, A. K.; Arora, B. M.

    1990-09-01

    Thermal processing of InP at temperatures above 500 °C is indispensable in the growth and device fabrication of InGaAsP alloy semiconductors for optoelectronic and microwave applications. Incongruous loss of P at these temperatures creates native defects and their complexes. The presence of such defects modifies the electrical and optical properties of the material resulting in poor device performance. In addition, native defects play a significant role in dopant diffusion which is a topic of current interest. We have measured deep-level photoluminescence (PL) on undoped InP after heat treatments at 500 and 550 °C in an open-tube processing system in different protective environments of powder InP, and Sn-InP melt together with an InP cover. In this paper we shall present the PL results which have bearing on the question of defects. We find that (1) the Sn-InP melt provides better protection in preserving the overall luminescence in InP; (2) the deep-level PL related to defects has at least two components in the virgin samples, viz., MnIn, and band C, which is a native defect complex related to VP; (3) a new defect appears in samples heated in a P-deficient environment; and (4) the enhancement in the deep-level luminescence intensity after heat treatment can be attributed to the excess defect concentrations existing under nonequilibrium conditions of an open-tube processing environment.

  5. Predicting the losses in sawtimber volume and quality from fires in oak-hickory forests.

    Treesearch

    Robert M. Loomis

    1974-01-01

    Presents a method for predicting future sawtimber losses due to fire-caused wounds. Losses are in terms of: (1) lumber value in dollars, (2) volume in board feet, (3) length of defect in feet, and (4) cross sectional area of defect in square inches. The methods apply to northern red, black, scarlet, white and chestnut oaks.

  6. Panorama of Reconstruction of Skull Base Defects: From Traditional Open to Endonasal Endoscopic Approaches, from Free Grafts to Microvascular Flaps

    PubMed Central

    Reyes, Camilo; Mason, Eric; Solares, C. Arturo

    2014-01-01

    Introduction A substantial body of literature has been devoted to the distinct characteristics and surgical options to repair the skull base. However, the skull base is an anatomically challenging location that requires a three-dimensional reconstruction approach. Furthermore, advances in endoscopic skull base surgery encompass a wide range of surgical pathology, from benign tumors to sinonasal cancer. This has resulted in the creation of wide defects that yield a new challenge in skull base reconstruction. Progress in technology and imaging has made this approach an internationally accepted method to repair these defects. Objectives Discuss historical developments and flaps available for skull base reconstruction. Data Synthesis Free grafts in skull base reconstruction are a viable option in small defects and low-flow leaks. Vascularized flaps pose a distinct advantage in large defects and high-flow leaks. When open techniques are used, free flap reconstruction techniques are often necessary to repair large entry wound defects. Conclusions Reconstruction of skull base defects requires a thorough knowledge of surgical anatomy, disease, and patient risk factors associated with high-flow cerebrospinal fluid leaks. Various reconstruction techniques are available, from free tissue grafting to vascularized flaps. Possible complications that can befall after these procedures need to be considered. Although endonasal techniques are being used with increasing frequency, open techniques are still necessary in selected cases. PMID:25992142

  7. Phonons, defects and optical damage in crystalline acetanilide

    NASA Astrophysics Data System (ADS)

    Kosic, Thomas J.; Hill, Jeffrey R.; Dlott, Dana D.

    1986-04-01

    Intense picosecond pulses cause accumulated optical damage in acetanilide crystals at low temperature. Catastrophic damage to the irradiated volume occurs after an incubation period where defects accumulate. The optical damage is monitored with subanosecond time resolution. The generation of defects is studied with damage-detected picosecond spectroscopy. The accumulation of defects is studied by time-resolved coherent Raman scattering, which is used to measure optical phonon scattering from the accumulating defects.

  8. Positron annihilation studies of silicon-based materials

    NASA Astrophysics Data System (ADS)

    Petkov, Mihail Petkov

    Positron Annihilation Spectroscopy (PAS) is used as a defect-profiling tool in the characterization of Si-based materials. PAS, in conjunction with variable energy positron beams, is a non-destructive depth-profiling probe, ideally suited for studying thin films, multi-layered structures, and buried interfaces. Its sensitivity to open-volume defects covers a wide range of defect sizes and concentrations, and surpasses that of most other techniques. This dissertation presents PAS investigations of electrical, chemical and mechanical properties of a number of advanced materials for future use by the semiconductor industry. Among the subjects of this work are: hydrogenated amorphous silicon (a-Si:H) for use in solar cells and flat-panel displays; low dielectric constant materials (low-k) for interlayer dielectrics; and thin-gate transistors, focusing on the defects at the Si/SiO 2 interface, which limit the device reliability. Results from extensive research on various possibilities to enhance the PAS capability by increasing its efficiency are presented in the appendices. The recognition of different dangling bond defects for low defect densities is achieved in these first PAS studies of void-free a-Si:H. Direct evidence of the existence of dopant-defect complexes is obtained for the first time. This research lays the foundation for future studies of the role of the impurities in light- and thermal degradation of a-Si:H PAS was applied to the characterization of porous low-k dielectrics. The annihilation observables are correlated with the dielectric properties of the material and their preparation conditions. PAS is the only non-destructive local k-probe, and the only tool for measuring void densities and sizes. The method is also sensitive to the chemical environment of the voids, seen during oxidation, water absorption, and forming gas anneal. Industrial research, partially based on these results, is currently in progress at IBM. A decade-old controversy, involving different models of defect states at Si/SiO2 interfaces, has been resolved. The two-defect model was confirmed and previous results were reevaluated. Research in this area will promote the use of PAS as an on-line diagnostic tool in the manufacturing of integrated circuits.

  9. Self-evolving atomistic kinetic Monte Carlo simulations of defects in materials

    DOE PAGES

    Xu, Haixuan; Beland, Laurent K.; Stoller, Roger E.; ...

    2015-01-29

    The recent development of on-the-fly atomistic kinetic Monte Carlo methods has led to an increased amount attention on the methods and their corresponding capabilities and applications. In this review, the framework and current status of Self-Evolving Atomistic Kinetic Monte Carlo (SEAKMC) are discussed. SEAKMC particularly focuses on defect interaction and evolution with atomistic details without assuming potential defect migration/interaction mechanisms and energies. The strength and limitation of using an active volume, the key concept introduced in SEAKMC, are discussed. Potential criteria for characterizing an active volume are discussed and the influence of active volume size on saddle point energies ismore » illustrated. A procedure starting with a small active volume followed by larger active volumes was found to possess higher efficiency. Applications of SEAKMC, ranging from point defect diffusion, to complex interstitial cluster evolution, to helium interaction with tungsten surfaces, are summarized. A comparison of SEAKMC with molecular dynamics and conventional object kinetic Monte Carlo is demonstrated. Overall, SEAKMC is found to be complimentary to conventional molecular dynamics, especially when the harmonic approximation of transition state theory is accurate. However it is capable of reaching longer time scales than molecular dynamics and it can be used to systematically increase the accuracy of other methods such as object kinetic Monte Carlo. Furthermore, the challenges and potential development directions are also outlined.« less

  10. Effect of Resorbable Collagen Plug on Bone Regeneration in Rat Critical-Size Defect Model.

    PubMed

    Liu, Weiqing; Kang, Ning; Dong, Yuliang; Guo, Yuchen; Zhao, Dan; Zhang, Shiwen; Zhou, Liyan; Seriwatanachai, Dutmanee; Liang, Xing; Yuan, Quan

    2016-04-01

    The purpose of this investigation was to examine the effect of resorbable collagen plug (RCP) on bone regeneration in rat calvarial critical-size defects. About 5-mm-diameter calvarial defects were created in forty 12-week-old male Sprague-Dawley rats and implanted with or without RCP. Animals were killed at 1, 2, 4, and 8 weeks postoperatively. After being killed, specimens were collected and subjected to micro-computed tomography (μCT) and histological analysis. The μCT showed a significant increase of newly formed bone volume/tissue volume in RCP-implanted defect compared with controls at all designated time points. After 8 weeks, the defects implanted with RCP displayed almost complete closure. Hematoxylin and eosin staining of the decalcified sections confirmed these observations and evidenced active bone regeneration in the RCP group. In addition, Masson's trichrome staining demonstrated that RCP implantation accelerated the process of collagen maturation. The RCP enhances bone regeneration in rat critical-size cranial defects, which suggest it might be a desired material for bone defect repair.

  11. [Submental island pedicled flap combination with bio-membrane for reconstructing the piercing palate defects].

    PubMed

    Liu, Hanqian; Yu, Huiming; Liu, Jiawu; Fang, Jin; Mao, Chi

    2015-05-01

    To evaluate the clinical outcomes of submental island pedicled flap (SIPF) combination with bio-membrane in reconstructing palate defects after maxillofacial or palatal neoplasm resection. There were 12 patients with squamous cell carcinoma and one patient with adenoid cystic carcinoma. The clinical stages of tumours were II in two patients, III in four patients, IV in six patients (UICC 2002), and one patient with adenoid cystic carcinoma no staged. SIPFs were designed and created, and the tissue sides of the SIPFs were covered with bio-membrane to reconstruct the oral and the nasal sides of the defects respectively. Speech and swallowing functions and opening mouth were evaluated 6 months postoperatively. All flaps survived and no serious complications occurred. Ten patients achieved normal speech, two had intelligible speech, and one was with slurred speech; Nine patients resumed a solid diet, three with a soft diet, and one on a liquid diet. Eight patients recovered normal mouth opening, four emerged minor limitation of mouth opening, and one had serious limitation of mouth opening. SIPF combined with bio-membrane is a safe, simple, and reliable method for reconstruction of piercing palate defect following neoplasm ablation, with satisfactory oral functions.

  12. Rapid orthodontic treatment after the ridge-splitting technique--a combined surgical-orthodontic approach for implant site development: case report.

    PubMed

    Amato, Francesco; Mirabella, A Davide; Borlizzi, Diego

    2012-08-01

    This article presents a clinical case of bilateral partial edentulism in the posterior mandible with severe horizontal and moderate vertical bone atrophy. A new technique using rapid orthodontics after ridge splitting is presented. The split-crest technique was carried out using piezosurgical instruments in the first molar and second premolar areas to widen the bone crest and open a channel for tooth movement. Immediately after, orthodontic appliances were used to move the first premolars distally and the second molars mesially into the surgical site. The rationale was to facilitate and accelerate orthodontic movement of the teeth, which is otherwise difficult in a cortical knife-edged ridge. The bone defect was filled with the alveolar bone of the adjacent teeth that were moved into the surgically opened path. Adequate bone volume for implant placement was generated in the first premolar area. Implants were then inserted, and the patient was rehabilitated.

  13. 17 CFR 16.01 - Trading volume, open contracts, prices, and critical dates.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Trading volume, open contracts... TRADING COMMISSION REPORTS BY REPORTING MARKETS § 16.01 Trading volume, open contracts, prices, and critical dates. (a) Trading volume and open contracts. Each reporting market shall record for each business...

  14. 17 CFR 16.01 - Trading volume, open contracts, prices, and critical dates.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 1 2011-04-01 2011-04-01 false Trading volume, open contracts... TRADING COMMISSION REPORTS BY REPORTING MARKETS § 16.01 Trading volume, open contracts, prices, and critical dates. (a) Trading volume and open contracts. Each reporting market shall record for each business...

  15. Epigenetic silencing of MLH1 in endometrial cancers is associated with larger tumor volume, increased rate of lymph node positivity and reduced recurrence-free survival.

    PubMed

    Cosgrove, Casey M; Cohn, David E; Hampel, Heather; Frankel, Wendy L; Jones, Dan; McElroy, Joseph P; Suarez, Adrian A; Zhao, Weiqiang; Chen, Wei; Salani, Ritu; Copeland, Larry J; O'Malley, David M; Fowler, Jeffrey M; Yilmaz, Ahmet; Chassen, Alexis S; Pearlman, Rachel; Goodfellow, Paul J; Backes, Floor J

    2017-09-01

    To determine the relationship between mismatch repair (MMR) classification and clinicopathologic features including tumor volume, and explore outcomes by MMR class in a contemporary cohort. Single institution cohort evaluating MMR classification for endometrial cancers (EC). MMR immunohistochemistry (IHC)±microsatellite instability (MSI) testing and reflex MLH1 methylation testing was performed. Tumors with MMR abnormalities by IHC or MSI and MLH1 methylation were classified as epigenetic MMR deficiency while those without MLH1 methylation were classified as probable MMR mutations. Clinicopathologic characteristics were analyzed. 466 endometrial cancers were classified; 75% as MMR proficient, 20% epigenetic MMR defects, and 5% as probable MMR mutations. Epigenetic MMR defects were associated with advanced stage, higher grade, presence of lymphovascular space invasion, and older age. MMR class was significantly associated with tumor volume, an association not previously reported. The epigenetic MMR defect tumors median volume was 10,220mm 3 compared to 3321mm 3 and 2,846mm 3 , for MMR proficient and probable MMR mutations respectively (P<0.0001). Higher tumor volume was associated with lymph node involvement. Endometrioid EC cases with epigenetic MMR defects had significantly reduced recurrence-free survival (RFS). Among advanced stage (III/IV) endometrioid EC the epigenetic MMR defect group was more likely to recur compared to the MMR proficient group (47.7% vs 3.4%) despite receiving similar adjuvant therapy. In contrast, there was no difference in the number of early stage recurrences for the different MMR classes. MMR testing that includes MLH1 methylation analysis defines a subset of tumors that have worse prognostic features and reduced RFS. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. A novel method to estimate the volume of bone defects using cone-beam computed tomography: an in vitro study.

    PubMed

    Esposito, Stefano Andrea; Huybrechts, Bart; Slagmolen, Pieter; Cotti, Elisabetta; Coucke, Wim; Pauwels, Ruben; Lambrechts, Paul; Jacobs, Reinhilde

    2013-09-01

    The routine use of high-resolution images derived from 3-dimensional cone-beam computed tomography (CBCT) datasets enables the linear measurement of lesions in the maxillary and mandibular bones on 3 planes of space. Measurements on different planes would make it possible to obtain real volumetric assessments. In this study, we tested, in vitro, the accuracy and reliability of new dedicated software developed for volumetric lesion assessment in clinical endodontics. Twenty-seven bone defects were created around the apices of 8 teeth in 1 young bovine mandible to simulate periapical lesions of different sizes and shapes. The volume of each defect was determined by taking an impression of the defect using a silicone material. The samples were scanned using an Accuitomo 170 CBCT (J. Morita Mfg Co, Kyoto, Japan), and the data were uploaded into a newly developed dedicated software tool. Two endodontists acted as independent and calibrated observers. They analyzed each bone defect for volume. The difference between the direct volumetric measurements and the measurements obtained with the CBCT images was statistically assessed using a lack-of-fit test. A correlation study was undertaken using the Pearson product-moment correlation coefficient. Intra- and interobserver agreement was also evaluated. The results showed a good fit and strong correlation between both volume measurements (ρ > 0.9) with excellent inter- and intraobserver agreement. Using this software, CBCT proved to be a reliable method in vitro for the estimation of endodontic lesion volumes in bovine jaws. Therefore, it may constitute a new, validated technique for the accurate evaluation and follow-up of apical periodontitis. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  17. Integrated circuit failure analysis by low-energy charge-induced voltage alteration

    DOEpatents

    Cole, E.I. Jr.

    1996-06-04

    A scanning electron microscope apparatus and method are described for detecting and imaging open-circuit defects in an integrated circuit (IC). The invention uses a low-energy high-current focused electron beam that is scanned over a device surface of the IC to generate a charge-induced voltage alteration (CIVA) signal at the location of any open-circuit defects. The low-energy CIVA signal may be used to generate an image of the IC showing the location of any open-circuit defects. A low electron beam energy is used to prevent electrical breakdown in any passivation layers in the IC and to minimize radiation damage to the IC. The invention has uses for IC failure analysis, for production-line inspection of ICs, and for qualification of ICs. 5 figs.

  18. Integrated circuit failure analysis by low-energy charge-induced voltage alteration

    DOEpatents

    Cole, Jr., Edward I.

    1996-01-01

    A scanning electron microscope apparatus and method are described for detecting and imaging open-circuit defects in an integrated circuit (IC). The invention uses a low-energy high-current focused electron beam that is scanned over a device surface of the IC to generate a charge-induced voltage alteration (CIVA) signal at the location of any open-circuit defects. The low-energy CIVA signal may be used to generate an image of the IC showing the location of any open-circuit defects. A low electron beam energy is used to prevent electrical breakdown in any passivation layers in the IC and to minimize radiation damage to the IC. The invention has uses for IC failure analysis, for production-line inspection of ICs, and for qualification of ICs.

  19. Technical considerations in harvesting and sawing defective hardwood butts

    Treesearch

    Thomas W., Jr. Church; Thomas W. Church

    1971-01-01

    How important are butt defects in hardwoods? We have no reliable estimate of the volume or value of timber lost through basal injuries. However, butt defects will be almost as important in future timber harvests as they are at present. Why? Because most butt defects are due to two causes: fire and logging. Damage from both these agents may be reduced, but it certainly...

  20. SiO 2/SiC interface proved by positron annihilation

    NASA Astrophysics Data System (ADS)

    Maekawa, M.; Kawasuso, A.; Yoshikawa, M.; Itoh, H.

    2003-06-01

    We have studied positron annihilation in a Silicon carbide (SiC)-metal/oxide/semiconductor (MOS) structure using a monoenergetic positron beam. The Doppler broadening of annihilation quanta were measured as functions of the incident positron energy and the gate bias. Applying negative gate bias, significant increases in S-parameters were observed. This indicates the migration of implanted positrons towards SiO 2/SiC interface and annihilation at open-volume type defects. The behavior of S-parameters depending on the bias voltage was well correlated with the capacitance-voltage ( C- V) characteristics. We observed higher S-parameters and the interfacial trap density in MOS structures fabricated using the dry oxidation method as compared to those by pyrogenic oxidation method.

  1. Positron annihilation lifetime spectroscopy study of Kapton thin foils

    NASA Astrophysics Data System (ADS)

    Kanda, G. S.; Ravelli, L.; Löwe, B.; Egger, W.; Keeble, D. J.

    2016-01-01

    Variable energy positron annihilation lifetime spectroscopy (VE-PALS) experiments on polyimide material Kapton are reported. Thin Kapton foils are widely used in a variety of mechanical, electronic applications. PALS provides a sensitive probe of vacancy-related defects in a wide range of materials, including open volume in polymers. Varying the positron implantation energy enables direct measurement of thin foils. Thin Kapton foils are also commonly used to enclose the positron source material in conventional PALS measurements performed with unmoderated radionuclide sources. The results of depth-profiled positron lifetime measurements on 7.6 μm and 25 μm Kapton foils are reported and determine a dominant 385(1) ps lifetime component. The absence of significant nanosecond lifetime component due to positronium formation is confirmed.

  2. Growth and analysis of micro and nano CdTe arrays for solar cell applications

    NASA Astrophysics Data System (ADS)

    Aguirre, Brandon Adrian

    CdTe is an excellent material for infrared detectors and photovoltaic applications. The efficiency of CdTe/CdS solar cells has increased very rapidly in the last 3 years to ˜20% but is still below the maximum theoretical value of 30%. Although the short-circuit current density is close to its maximum of 30 mA/cm2, the open circuit voltage has potential to be increased further to over 1 Volt. The main limitation that prevents further increase in the open-circuit voltage and therefore efficiency is the high defect density in the CdTe absorber layer. Reducing the defect density will increase the open-circuit voltage above 1 V through an increase in the carrier lifetime and concentration to tau >10 ns and p > 10 16 cm-3, respectively. However, the large lattice mismatch (10%) between CdTe and CdS and the polycrystalline nature of the CdTe film are the fundamental reasons for the high defect density and pose a difficult challenge to solve. In this work, a method to physically and electrically isolate the different kinds of defects at the nanoscale and understand their effect on the electrical performance of CdTe is presented. A SiO2 template with arrays of window openings was deposited between the CdTe and CdS to achieve selective-area growth of the CdTe via close-space sublimation. The diameter of the window openings was varied from the micro to the nanoscale to study the effect of size on nucleation, grain growth, and defect density. The resulting structures enabled the possibility to electrically isolate and individually probe micrometer and nanoscale sized CdTe/CdS cells. Electron back-scattered diffraction was used to observe grain orientation and defects in the miniature cells. Scanning and transmission electron microscopy was used to study the morphology, grain boundaries, grain orientation, defect structure, and strain in the layers. Finally, conducting atomic force microscopy was used to study the current-voltage characteristics of the solar cells. An important part of this work was the ability to directly correlate the one-to-one relationship between the electrical performance and defect structure of individual nanoscale cells. This method is general and can be applied to other material systems to study the electrical-microstructure relationship on a one-to-one basis with nanoscale resolution.

  3. Neurological outcomes by mode of delivery for fetuses with open neural tube defects: A systematic review and meta-analysis.

    PubMed

    Tolcher, Mary C; Shazly, Sherif A; Shamshirsaz, Alireza A; Whitehead, William E; Espinoza, Jimmy; Vidaeff, Alex C; Belfort, Michael A; Nassr, Ahmed A

    2018-06-20

    Controversy exists regarding the optimal mode of delivery for fetuses with open neural tube defects. To compare neurological outcomes among infants with open neural tube defects who underwent vaginal compared to caesarean delivery. Electronic databases MEDLINE, EMBASE, Scopus, and Clinicaltrials. gov were searched from inception to November 2017. Eligible studies included observational or randomised studies comparing vaginal and caesarean delivery in pregnancies with fetal open neural tube defects who did not undergo prenatal repair. Two reviewers independently reviewed abstracts and full text articles. Outcomes were compared between vaginal and caesarean delivery and prelabour caesarean versus labour. The primary outcome was motor-anatomic level difference. Secondary outcomes included shunt requirement, sac disruption, meningitis, and ambulation at 2 years. Meta-analysis was performed and mean difference or odds ratios with 95% confidence interval calculated. Of 201 abstracts identified in the primary search, 9 studies (672 women) met eligibility criteria. Comparing vaginal and caesarean delivery, there was no significant difference in motor-anatomic level difference (mean difference -0.10, 95% CI -0.58-0.38; I 2 =57%). The vaginal delivery group was less likely to require a shunt or have sac disruption (OR 0.37, 95% CI 0.14-0.95 and OR 0.46, 95% CI 0.23-0.90, respectively). Comparisons by prelabour caesarean versus labour showed no significant difference in motor-anatomic level difference (OR 1.29, 95% CI -0.63-3.21) or ambulation at 2 years (OR 2.13, 95% CI 0.35-13.12). Caesarean delivery was not associated with improved neurological outcomes among fetuses with open neural tube defects. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Tissue-engineered bone constructed in a bioreactor for repairing critical-sized bone defects in sheep.

    PubMed

    Li, Deqiang; Li, Ming; Liu, Peilai; Zhang, Yuankai; Lu, Jianxi; Li, Jianmin

    2014-11-01

    Repair of bone defects, particularly critical-sized bone defects, is a considerable challenge in orthopaedics. Tissue-engineered bones provide an effective approach. However, previous studies mainly focused on the repair of bone defects in small animals. For better clinical application, repairing critical-sized bone defects in large animals must be studied. This study investigated the effect of a tissue-engineered bone for repairing critical-sized bone defect in sheep. A tissue-engineered bone was constructed by culturing bone marrow mesenchymal-stem-cell-derived osteoblast cells seeded in a porous β-tricalcium phosphate ceramic (β-TCP) scaffold in a perfusion bioreactor. A critical-sized bone defect in sheep was repaired with the tissue-engineered bone. At the eighth and 16th week after the implantation of the tissue-engineered bone, X-ray examination and histological analysis were performed to evaluate the defect. The bone defect with only the β-TCP scaffold served as the control. X-ray showed that the bone defect was successfully repaired 16 weeks after implantation of the tissue-engineered bone; histological sections showed that a sufficient volume of new bones formed in β-TCP 16 weeks after implantation. Eight and 16 weeks after implantation, the volume of new bones that formed in the tissue-engineered bone group was more than that in the β-TCP scaffold group (P < 0.05). Tissue-engineered bone improved osteogenesis in vivo and enhanced the ability to repair critical-sized bone defects in large animals.

  5. The use of light emission in failure analysis of CMOS ICs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hawkins, C.F.; Soden, J.M.; Cole, E.I. Jr.

    1990-01-01

    The use of photon emission for analyzing failure mechanisms and defects in CMOS ICs is presented. Techniques are given for accurate identification and spatial localization of failure mechanisms and physical defects, including defects such as short and open circuits which do not themselves emit photons.

  6. The significance of the open bladder neck associated with pelvic fracture urethral distraction defects.

    PubMed

    Iselin, C E; Webster, G D

    1999-08-01

    As a result of pelvic fracture urethral distraction defects, urinary continence relies predominantly on intact bladder neck function. Hence, when cystoscopy and/or cystography reveals an open bladder neck before urethroplasty, the probability of postoperative urinary incontinence may be significant. Unresolved issues are the necessity, the timing and the type of bladder neck repair. We report the outcome of various therapeutic options in patients with pelvic fracture urethral distraction defects and open bladder neck. We also attempt to identify prognostic factors of incontinence before urethroplasty. We retrospectively reviewed the records of 15 patients with a mean age of 30 years in whom an open bladder neck was identified before posterior urethroplasty between January 1981 and October 1997. Of the 15 patients 6 were continent and 8 were incontinent postoperatively. One patient underwent artificial urethral sphincter implantation simultaneously with pelvic fracture urethral distraction defect repair and was dry postoperatively without sphincter activation. Average bladder neck and prostatic urethral opening on the cystourethrogram before urethroplasty was significantly longer in incontinent (1.68 cm.) than in continent (0.9 cm.) patients. Of the 8 patients who were incontinent 6 underwent bladder neck reconstruction, 1 artificial urinary sphincter and 1 periurethral collagen implant. Five patients with bladder neck reconstruction are totally continent and 1 requires 1 pad daily. The patient who underwent collagen implant requires 2 pads daily and the patient who received an artificial urethral sphincter has minor urge leakage. Open bladder neck before urethroplasty may herald postoperative incontinence which may be predicted by radiographic and cystoscopic features. Evaluation of the risk of postoperative incontinence may be valuable, and eventually guide the necessity and timing of anti-incontinence surgery, although our preference remains to manage the pelvic fracture urethral distraction defects and bladder neck problem sequentially. Bladder neck reconstruction provides good postoperative continence rates and is our technique of choice.

  7. A perfusion bioreactor system efficiently generates cell-loaded bone substitute materials for addressing critical size bone defects.

    PubMed

    Kleinhans, Claudia; Mohan, Ramkumar Ramani; Vacun, Gabriele; Schwarz, Thomas; Haller, Barbara; Sun, Yang; Kahlig, Alexander; Kluger, Petra; Finne-Wistrand, Anna; Walles, Heike; Hansmann, Jan

    2015-09-01

    Critical size bone defects and non-union fractions are still challenging to treat. Cell-loaded bone substitutes have shown improved bone ingrowth and bone formation. However, a lack of methods for homogenously colonizing scaffolds limits the maximum volume of bone grafts. Additionally, therapy robustness is impaired by heterogeneous cell populations after graft generation. Our aim was to establish a technology for generating grafts with a size of 10.5 mm in diameter and 25 mm of height, and thus for grafts suited for treatment of critical size bone defects. Therefore, a novel tailor-made bioreactor system was developed, allowing standardized flow conditions in a porous poly(L-lactide-co-caprolactone) material. Scaffolds were seeded with primary human mesenchymal stem cells derived from four different donors. In contrast to static experimental conditions, homogenous cell distributions were accomplished under dynamic culture. Additionally, culture in the bioreactor system allowed the induction of osteogenic lineage commitment after one week of culture without addition of soluble factors. This was demonstrated by quantitative analysis of calcification and gene expression markers related to osteogenic lineage. In conclusion, the novel bioreactor technology allows efficient and standardized conditions for generating bone substitutes that are suitable for the treatment of critical size defects in humans. © 2015 The Authors. Biotechnology Journal published by Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial Licence, which permits use, distribution and reproduction in any medium, provided the Contribution is properly cited and is not used for commercial purpose.

  8. Autogenous bone particle/titanium fiber composites for bone regeneration in a rabbit radius critical-size defect model.

    PubMed

    Xie, Huanxin; Ji, Ye; Tian, Qi; Wang, Xintao; Zhang, Nan; Zhang, Yicai; Xu, Jun; Wang, Nanxiang; Yan, Jinglong

    2017-11-01

    To explore the effects of autogenous bone particle/titanium fiber composites on repairing segmental bone defects in rabbits. A model of bilateral radial bone defect was established in 36 New Zealand white rabbits which were randomly divided into 3 groups according to filling materials used for bilaterally defect treatment: in group C, 9 animal bone defect areas were prepared into simple bilateral radius bone defect (empty sham) as the control group; 27 rabbits were used in groups ABP and ABP-Ti. In group ABP, left defects were simply implanted with autogenous bone particles; meanwhile, group ABP-Ti animals had right defects implanted with autogenous bone particle/titanium fiber composites. Animals were sacrificed at 4, 8, and 12 weeks, respectively, after operation. Micro-CT showed that group C could not complete bone regeneration. Bone volume to tissue volume values in group ABP-Ti were better than group ABP. From histology and histomorphometry Groups ABP and ABP-Ti achieved bone repair, the bone formation of group ABP-Ti was better. The mechanical strength of group ABP-Ti was superior to that of other groups. These results confirmed the effectiveness of autologous bone particle/titanium fiber composites for promoting bone regeneration and mechanical strength.

  9. Thermally-induced voltage alteration for integrated circuit analysis

    DOEpatents

    Cole, Jr., Edward I.

    2000-01-01

    A thermally-induced voltage alteration (TIVA) apparatus and method are disclosed for analyzing an integrated circuit (IC) either from a device side of the IC or through the IC substrate to locate any open-circuit or short-circuit defects therein. The TIVA apparatus uses constant-current biasing of the IC while scanning a focused laser beam over electrical conductors (i.e. a patterned metallization) in the IC to produce localized heating of the conductors. This localized heating produces a thermoelectric potential due to the Seebeck effect in any conductors with open-circuit defects and a resistance change in any conductors with short-circuit defects, both of which alter the power demand by the IC and thereby change the voltage of a source or power supply providing the constant-current biasing. By measuring the change in the supply voltage and the position of the focused and scanned laser beam over time, any open-circuit or short-circuit defects in the IC can be located and imaged. The TIVA apparatus can be formed in part from a scanning optical microscope, and has applications for qualification testing or failure analysis of ICs.

  10. 17 CFR 16.01 - Trading volume, open contracts, prices, and critical dates.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... TRADING COMMISSION REPORTS BY REPORTING MARKETS § 16.01 Trading volume, open contracts, prices, and critical dates. (a) Trading volume and open contracts. Each reporting market shall record for each business... total volume of trading. (b) Prices. Each reporting market shall record the following information...

  11. Characterization of electrically-active defects in ultraviolet light-emitting diodes with laser-based failure analysis techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Mary A.; Tangyunyong, Paiboon; Cole, Edward I.

    2016-01-14

    Laser-based failure analysis techniques demonstrate the ability to quickly and non-intrusively screen deep ultraviolet light-emitting diodes (LEDs) for electrically-active defects. In particular, two laser-based techniques, light-induced voltage alteration and thermally-induced voltage alteration, generate applied voltage maps (AVMs) that provide information on electrically-active defect behavior including turn-on bias, density, and spatial location. Here, multiple commercial LEDs were examined and found to have dark defect signals in the AVM indicating a site of reduced resistance or leakage through the diode. The existence of the dark defect signals in the AVM correlates strongly with an increased forward-bias leakage current. This increased leakage ismore » not present in devices without AVM signals. Transmission electron microscopy analysis of a dark defect signal site revealed a dislocation cluster through the pn junction. The cluster included an open core dislocation. Even though LEDs with few dark AVM defect signals did not correlate strongly with power loss, direct association between increased open core dislocation densities and reduced LED device performance has been presented elsewhere [M. W. Moseley et al., J. Appl. Phys. 117, 095301 (2015)].« less

  12. Characterization of electrically-active defects in ultraviolet light-emitting diodes with laser-based failure analysis techniques

    DOE PAGES

    Miller, Mary A.; Tangyunyong, Paiboon; Edward I. Cole, Jr.

    2016-01-12

    In this study, laser-based failure analysis techniques demonstrate the ability to quickly and non-intrusively screen deep ultraviolet light-emitting diodes(LEDs) for electrically-active defects. In particular, two laser-based techniques, light-induced voltage alteration and thermally-induced voltage alteration, generate applied voltage maps (AVMs) that provide information on electrically-active defect behavior including turn-on bias, density, and spatial location. Here, multiple commercial LEDs were examined and found to have dark defect signals in the AVM indicating a site of reduced resistance or leakage through the diode. The existence of the dark defect signals in the AVM correlates strongly with an increased forward-bias leakage current. This increasedmore » leakage is not present in devices without AVM signals. Transmission electron microscopyanalysis of a dark defect signal site revealed a dislocation cluster through the pn junction. The cluster included an open core dislocation. Even though LEDs with few dark AVM defect signals did not correlate strongly with power loss, direct association between increased open core dislocation densities and reduced LED device performance has been presented elsewhere [M. W. Moseley et al., J. Appl. Phys. 117, 095301 (2015)].« less

  13. Stress-dependence of kinetic transitions at atomistic defects

    NASA Astrophysics Data System (ADS)

    Ball, S. L.; Alexander, K. C.; Schuh, C. A.

    2018-01-01

    The full second-rank activation volume tensors associated with vacancy migration in FCC copper and HCP titanium as well as transition events in the Σ5 (2 1 0) grain boundary in copper are calculated and analyzed. The full tensorial results quantitatively illustrate how the conventional use of an activation volume scalar in atomistic studies of the kinetic processes of complex defects can miss important stress dependencies, in that neither hydrostatic pressure nor deviatoric stress dependencies can be considered alone as dominating the response. The results speak to the importance of anisotropies in the stress-dependence of atomistic kinetics, including crystal structure anisotropy, elastic anisotropy, and defect structure or migration-path anisotropies.

  14. Primary detection of hardwood log defects using laser surface scanning

    Treesearch

    Ed Thomas; Liya Thomas; Lamine Mili; Roger Ehrich; A. Lynn Abbott; Clifford Shaffer; Clifford Shaffer

    2003-01-01

    The use of laser technology to scan hardwood log surfaces for defects holds great promise for improving processing efficiency and the value and volume of lumber produced. External and internal defect detection to optimize hardwood log and lumber processing is one of the top four technological needs in the nation's hardwood industry. The location, type, and...

  15. An open randomized controlled clinical trial to evaluate ridge preservation and repair using SocketKAP(™) and SocketKAGE(™) : part 2 - three-dimensional alveolar bone volumetric analysis of CBCT imaging.

    PubMed

    Abdelhamid, Alaa; Omran, Mostafa; Bakhshalian, Neema; Tarnow, Dennis; Zadeh, Homayoun H

    2016-06-01

    The aims of this study were (i) to evaluate the efficacy of ridge preservation and repair procedures involving the application of SocketKAP(™) and SocketKAGE(™) devices following tooth removal and (ii) to evaluate alveolar bone volumetric changes at 6 months post-extraction in intact sockets or those with facial wall dehiscence defects using 3-dimensional pre- and postoperative CBCT data. Thirty-six patients required 61 teeth extracted. Five cohorts were established: Group A: Intact Socket Negative Control Group B: Intact Socket + SocketKAP(™) Group C: Intact Socket Filled with Anorganic Bovine Bone Mineral (ABBM) + SocketKAP(™) Group D: Facial Dehiscence Socket Negative Control Group E: Facial Dehiscence Socket Filled with ABBM + SocketKAP(™) + SocketKAGE(™) . Preoperative CBCT scans were obtained followed by digital subtraction of the test teeth. At 6 months post-extraction, another CBCT scan was obtained. The pre- and postoperative scans were then superimposed, allowing highly accurate quantitative determination of the 3D volumetric alveolar bone volume changes from baseline through 6 months. Significant volumetric bone loss occurred in all sockets, localized mainly in the 0-3 mm zone apical to the ridge crest. For intact sockets, SocketKAP(™) + ABBM treatment led to a statistically significant greater percentage of remaining mineralized tissue volume when compared to negative control group. A significant difference favoring SocketKAP(™) + SocketKAGE(™) + ABBM treatment was observed for sockets with facial dehiscence defects compared to the negative control group. SocketKAP(™) , with ABBM, appears effective in limiting post-extraction volumetric bone loss in intact sockets, while SocketKAP(™) + SocketKAGE + ABBM appears effective in limiting post-extraction bone loss in sockets with dehiscence defects. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Ocular characteristics associated with the location of focal lamina cribrosa defects in open-angle glaucoma patients.

    PubMed

    Park, H-Yl; Hwang, Y S; Park, C K

    2017-04-01

    PurposeTo investigate the clinical characteristics according to the location of focal lamina cribrosa (LC) defects and its associated ocular features.Patients and methodsA total of 139 open-angle glaucoma patients underwent Spectralis optical coherence tomography (OCT) with enhanced depth imaging. Alterations in the contour of the LC were investigated to find focal LC defects. The location of the visible LC defect from the neural canal wall (far-peripheral and mid-peripheral) and clock-hour position (superotemporal, temporal and inferotemporal) were classified. Disc ovality ratio and disc-foveal angle were measured from disc and retinal nerve fiber layer (RNFL) photographs. The disc tilt degree was measured using a Heidelberg Retina Tomograph (HRT) III system. The en face OCT image of the disc scans was registered to the disc and RNFL photographs, to determine whether the focal LC defects corresponded spatially to the glaucomatous damage location.ResultsEyes with far-peripheral LC defects were significantly myopic and had a higher disc ovality ratio. The disc tilt degree obtained by HRT revealed significant temporal disc tilt in eyes with temporal LC defects (P<0.001). Eyes with inferotemporal LC defects had a significantly larger disc-foveal angle (P=0.027). The inferotemporal LC defects corresponded to the location of glaucomatous damage in 81.6%; however, only 46.2% of eyes with a superotemporal LC defect and 3.2% of eyes with a temporal LC defect corresponded spatially with the glaucomatous damage location.ConclusionsThe clinical characteristics and association with glaucomatous damage location were different according to the location of focal LC defect.

  17. [Early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect].

    PubMed

    Xiao, Jian; Mao, Zhao-Guang; Zhu, Hui-Hua; Guo, Liang

    2017-03-25

    To discuss the curative effect of the early application of the antibiotic-laden bone cement (ALBC) combined with the external fixation support in treating the open fractures of lower limbs complicated with bone defect. From December 2013 to January 2015, 36 cases of lower limb open comminuted fractures complicated with bone defects were treated by the vancomycin ALBC combined with the external fixation support, including 26 males and 10 females with an average age of 38.0 years old ranging from 19 to 65 years old. The included cases were all open fractures of lower limbs complicated with bone defects with different degree of soft tissue injuries. Among them, 25 cases were tibial fractures, 11 cases were femoral fractures. The radiographs indicated a presence of bone defects, which ranged from 3.0 to 6.1 cm with an average of 4.0 cm. The Gustilo classification of open fractures:24 cases were type IIIA, 12 cases were typr IIIB. The percentage of wound infection, bone grafting time, fracture healing time and postoperative joint function of lower limb were observed. The function of injured limbs was evaluated at 1 month after the clinical healing of fracture based on Paley evaluation criterion. All cases were followed up for 3 to 24 months with an average of (6.0±3.0) months. The wound surface was healed well, neither bone infections nor unhealed bone defects were presented. The reoperation of bone grafting was done at 6 weeks after the patients received an early treatment with ALBC, some of them were postponed to 8 weeks till the approximate healing of fractures, the treatment course lasted for 4 to 8 months with an average of(5.5±1.5) months. According to Paley and other grading evaluations of bone and function, there were 27 cases as excellent, 5 cases as good, 3 cases as ordinary. The ALBC combined with external fixation support was an effective method for early treatment to treat the traumatic lower limb open fractures complicated with bone defects. This method was typified with the advantages such as easy operation, short operation time, overwhelming superiority in controlling infection and provision of good bone grafting bed, a good bone healing can be realized by the use of membrane induction technology for bone grafting.

  18. Nuclear envelope expansion is crucial for proper chromosomal segregation during a closed mitosis.

    PubMed

    Takemoto, Ai; Kawashima, Shigehiro A; Li, Juan-Juan; Jeffery, Linda; Yamatsugu, Kenzo; Elemento, Olivier; Nurse, Paul

    2016-03-15

    Here, we screened a 10,371 library of diverse molecules using a drug-sensitive fission yeast strain to identify compounds which cause defects in chromosome segregation during mitosis. We identified a phosphorium-ylide-based compound Cutin-1 which inhibits nuclear envelope expansion and nuclear elongation during the closed mitosis of fission yeast, and showed that its target is the β-subunit of fatty acid synthase. A point mutation in the dehydratase domain of Fas1 conferred in vivo and in vitro resistance to Cutin-1. Time-lapse photomicrography showed that the bulk of the chromosomes were only transiently separated during mitosis, and nucleoli separation was defective. Subsequently sister chromatids re-associated leading to chromosomal mis-segregation. These segregation defects were reduced when the nuclear volume was increased and were increased when the nuclear volume was reduced. We propose that there needs to be sufficient nuclear volume to allow the nuclear elongation necessary during a closed mitosis to take place for proper chromosome segregation, and that inhibition of fatty acid synthase compromises nuclear elongation and leads to defects in chromosomal segregation. © 2016. Published by The Company of Biologists Ltd.

  19. Scanning electron microscope automatic defect classification of process induced defects

    NASA Astrophysics Data System (ADS)

    Wolfe, Scott; McGarvey, Steve

    2017-03-01

    With the integration of high speed Scanning Electron Microscope (SEM) based Automated Defect Redetection (ADR) in both high volume semiconductor manufacturing and Research and Development (R and D), the need for reliable SEM Automated Defect Classification (ADC) has grown tremendously in the past few years. In many high volume manufacturing facilities and R and D operations, defect inspection is performed on EBeam (EB), Bright Field (BF) or Dark Field (DF) defect inspection equipment. A comma separated value (CSV) file is created by both the patterned and non-patterned defect inspection tools. The defect inspection result file contains a list of the inspection anomalies detected during the inspection tools' examination of each structure, or the examination of an entire wafers surface for non-patterned applications. This file is imported into the Defect Review Scanning Electron Microscope (DRSEM). Following the defect inspection result file import, the DRSEM automatically moves the wafer to each defect coordinate and performs ADR. During ADR the DRSEM operates in a reference mode, capturing a SEM image at the exact position of the anomalies coordinates and capturing a SEM image of a reference location in the center of the wafer. A Defect reference image is created based on the Reference image minus the Defect image. The exact coordinates of the defect is calculated based on the calculated defect position and the anomalies stage coordinate calculated when the high magnification SEM defect image is captured. The captured SEM image is processed through either DRSEM ADC binning, exporting to a Yield Analysis System (YAS), or a combination of both. Process Engineers, Yield Analysis Engineers or Failure Analysis Engineers will manually review the captured images to insure that either the YAS defect binning is accurately classifying the defects or that the DRSEM defect binning is accurately classifying the defects. This paper is an exploration of the feasibility of the utilization of a Hitachi RS4000 Defect Review SEM to perform Automatic Defect Classification with the objective of the total automated classification accuracy being greater than human based defect classification binning when the defects do not require multiple process step knowledge for accurate classification. The implementation of DRSEM ADC has the potential to improve the response time between defect detection and defect classification. Faster defect classification will allow for rapid response to yield anomalies that will ultimately reduce the wafer and/or the die yield.

  20. Genetics Home Reference: abdominal wall defect

    MedlinePlus

    ... are two main types of abdominal wall defects: omphalocele and gastroschisis . Omphalocele is an opening in the center of the ... covering the exposed organs in gastroschisis. Fetuses with omphalocele may grow slowly before birth (intrauterine growth retardation) ...

  1. Influence of deep defects on device performance of thin-film polycrystalline silicon solar cells

    NASA Astrophysics Data System (ADS)

    Fehr, M.; Simon, P.; Sontheimer, T.; Leendertz, C.; Gorka, B.; Schnegg, A.; Rech, B.; Lips, K.

    2012-09-01

    Employing quantitative electron-paramagnetic resonance analysis and numerical simulations, we investigate the performance of thin-film polycrystalline silicon solar cells as a function of defect density. We find that the open-circuit voltage is correlated to the density of defects, which we assign to coordination defects at grain boundaries and in dislocation cores. Numerical device simulations confirm the observed correlation and indicate that the device performance is limited by deep defects in the absorber bulk. Analyzing the defect density as a function of grain size indicates a high concentration of intra-grain defects. For large grains (>2 μm), we find that intra-grain defects dominate over grain boundary defects and limit the solar cell performance.

  2. Method for growing low defect, high purity crystalline layers utilizing lateral overgrowth of a patterned mask

    NASA Technical Reports Server (NTRS)

    Morrison, Andrew D. (Inventor); Daud, Taher (Inventor)

    1986-01-01

    A method for growing a high purity, low defect layer of semiconductor is described. This method involves depositing a patterned mask of a material impervious to impurities of the semiconductor on a surface of a blank. When a layer of semiconductor is grown on the mask, the semiconductor will first grow from the surface portions exposed by the openings in the mask and will bridge the connecting portions of the mask to form a continuous layer having improved purity, since only the portions overlying the openings are exposed to defects and impurities. The process can be iterated and the mask translated to further improve the quality of grown layers.

  3. Use of Polymethyl Methacrylate-Based Cement for Cosmetic Correction of Donor-Site Defect following Transposition of Temporalis Myofascial Flap and Evaluation of Results after Adjuvant Radiotherapy.

    PubMed

    Mandlik, Dushyant; Gupta, Karan; Patel, Daxesh; Patel, Purvi; Toprani, Rajendra; Patel, Kaustubh

    2015-11-01

    Temporalis myofascial flap is a versatile flap for reconstruction of the oral cavity defects, but results in an esthetically compromised deformity at the donor site. We used polymethyl methacrylate (PMMA) cement to correct the volume loss defect caused by temporalis myofascial flap and evaluated its results before and after adjuvant radiotherapy. We discuss our experience of using PMMA cement to augment donor-site deformity in 25 patients (17 males, 8 females) between years 2005 and 2009. The primary defect was a result of the ablative surgery for squamous cell carcinoma of the upper alveolar and the buccoalveolar sulcus. A modified curved hemicoronal incision was used as an access for better cosmetic outcome. The volume of cement required was decided during the surgery. All patients are in regular follow-up, alive and free of complications at implant site, except one patient who developed wound dehiscence. The condition of the implant was evaluated by postoperative computed tomographic scan, repeated after adjuvant radiotherapy in cases required. There were no radiation-induced changes in the contour and volume of the implants. Cosmetic result of the implant was reported satisfactory by the patients postoperatively.  Restoration of the temporal area defect after the temporalis myofascial flap harvest with the use of PMMA cement is an easy and safe method, with excellent esthetic results. The implant is stable and resistant to any changes in contour and loss of volume even after adjuvant radiotherapy, with no added morbidity to the patients. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. Diagnostic Consistency and Relation Between Optical Coherence Tomography and Standard Automated Perimetry in Primary Open-Angle Glaucoma.

    PubMed

    Toprak, Ibrahim; Yaylalı, Volkan; Yildirim, Cem

    2017-01-01

    To assess diagnostic consistency and relation between spectral-domain optical coherence tomography (SD-OCT) and standard automated perimetry (SAP) in patients with primary open-angle glaucoma (POAG). This retrospective study comprised 51 eyes of 51 patients with a confirmed diagnosis of POAG. The qualitative and quantitative SD-OCT parameters (retinal nerve fiber layer thicknesses [RNFL; average, superior, inferior, nasal and temporal], RNFL symmetry, rim area, disc area, average and vertical cup/disc [C/D] ratio and cup volume) were compared with parameters of SAP (mean deviation, pattern standard deviation, visual field index, and glaucoma hemifield test reports). Fifty-one eyes of 51 patients with POAG were recruited. Twenty-nine eyes (56.9%) had consistent RNFL and visual field (VF) damage. However, nine patients (17.6%) showed isolated RNFL damage on SD-OCT and 13 patients (25.5%) had abnormal VF test with normal RNFL. In patients with VF defect, age, average C/D ratio, vertical C/D ratio, and cup volume were significantly higher and rim area was lower when compared to those of the patients with normal VF. In addition to these parameters, worsening in average, superior, inferior, and temporal RNFL thicknesses and RNFL symmetry was significantly associated with consistent SD-OCT and SAP outcomes. In routine practice, patients with POAG can be manifested with inconsistent reports between SD-OCT and SAP. An older age, higher C/D ratio, larger cup volume, and lower rim area on SD-OCT appears to be associated with detectable VF damage. Moreover, additional worsening in RNFL parameters might reinforce diagnostic consistency between SD-OCT and SAP.

  5. Comparison of naturally occurring and ligature-induced peri-implantitis bone defects in humans and dogs.

    PubMed

    Schwarz, Frank; Herten, Monika; Sager, Martin; Bieling, Katrin; Sculean, Anton; Becker, Jürgen

    2007-04-01

    The aim of the present study was to evaluate and compare naturally occuring and ligature-induced peri-implantitis bone defects in humans and dogs. Twenty-four partially and fully edentulous patients undergoing peri-implant bone augmentation procedures due to advanced peri-implant infections were included in this study (n=40 implants). Furthermore, peri-implantitis was induced by ligature placement and plaque accumulation in five beagle dogs for three months following implant insertion (n=15 implants). The ligatures were removed when about 30% of the initial bone was lost. During open flap surgery, configuration and defect characteristics of the peri-implant bone loss were recorded in both humans and dogs. Open flap surgery generally revealed two different classes of peri-implant bone defects. While Class I defects featured well-defined intrabony components, Class II defects were characterized by consistent horizontal bone loss. The allocation of intrabony components of Class I defects regarding the implant body allowed a subdivision of five different configurations (Classes Ia-e). In particular, human defects were most frequently Class Ie (55.3%), followed by Ib (15.8%), Ic (13.3%), Id (10.2%), and Ia (5.4%). Similarly, bone defects in dogs were also most frequently Class Ie (86.6%), while merely two out of 15 defects were Classes Ia and Ic (6.7%, respectively). Within the limits of the present study, it might be concluded that configurations and sizes of ligature-induced peri-implantitis bone defects in dogs seemed to resemble naturally occurring lesions in humans.

  6. Impact of patient-specific factors, irradiated left ventricular volume, and treatment set-up errors on the development of myocardial perfusion defects after radiation therapy for left-sided breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Elizabeth S.; Prosnitz, Robert G.; Yu Xiaoli

    2006-11-15

    Purpose: The aim of this study was to assess the impact of patient-specific factors, left ventricle (LV) volume, and treatment set-up errors on the rate of perfusion defects 6 to 60 months post-radiation therapy (RT) in patients receiving tangential RT for left-sided breast cancer. Methods and Materials: Between 1998 and 2005, a total of 153 patients were enrolled onto an institutional review board-approved prospective study and had pre- and serial post-RT (6-60 months) cardiac perfusion scans to assess for perfusion defects. Of the patients, 108 had normal pre-RT perfusion scans and available follow-up data. The impact of patient-specific factors onmore » the rate of perfusion defects was assessed at various time points using univariate and multivariate analysis. The impact of set-up errors on the rate of perfusion defects was also analyzed using a one-tailed Fisher's Exact test. Results: Consistent with our prior results, the volume of LV in the RT field was the most significant predictor of perfusion defects on both univariate (p = 0.0005 to 0.0058) and multivariate analysis (p = 0.0026 to 0.0029). Body mass index (BMI) was the only significant patient-specific factor on both univariate (p = 0.0005 to 0.022) and multivariate analysis (p = 0.0091 to 0.05). In patients with very small volumes of LV in the planned RT fields, the rate of perfusion defects was significantly higher when the fields set-up 'too deep' (83% vs. 30%, p = 0.059). The frequency of deep set-up errors was significantly higher among patients with BMI {>=}25 kg/m{sup 2} compared with patients of normal weight (47% vs. 28%, p = 0.068). Conclusions: BMI {>=}25 kg/m{sup 2} may be a significant risk factor for cardiac toxicity after RT for left-sided breast cancer, possibly because of more frequent deep set-up errors resulting in the inclusion of additional heart in the RT fields. Further study is necessary to better understand the impact of patient-specific factors and set-up errors on the development of RT-induced perfusion defects.« less

  7. Oral function after maxillectomy and reconstruction with an obturator.

    PubMed

    Kreeft, A M; Krap, M; Wismeijer, D; Speksnijder, C M; Smeele, L E; Bosch, S D; Muijen, M S A; Balm, A J M

    2012-11-01

    Maxillectomy defects can be reconstructed by a prosthetic obturator or (free) flap transfer, but there is no consensus about the optimal method. This study evaluated 32 maxillectomy patients with prosthetic obturation regarding function (mastication, subjective oral and swallowing complaints and maximal mouth opening). Outcomes were related to the extent of the resection (Brown maxillectomy classification), dentition and history of adjuvant radiotherapy. Maxillectomy defects ranged from 2-1 to 4B on the Brown classification, and most had a defect graded as 2-A or 2-B. Mean mixing ability test after 10 chewing strokes was 24.2 and after 20 chewing strokes 19.7, which compares to edentulous healthy individuals. None of the outcomes was influenced by Brown classification. Radiotherapy negatively influenced mean maximal mouth opening (29.1mm versus 40.9 mm, p=0.017) and subjective outcomes. Edentate obturated patients had worse outcomes than dentate patients, measured by mixing ability test and questionnaire. In conclusion, mastication after obturator reconstruction of a maxillectomy defect is comparable to mastication with full dentures. Size of the maxillectomy defect did not significantly influence functional outcome, but adjuvant radiotherapy resulted in worse mouth opening and self-reported oral and swallowing problems. Residual dentition had a positive influence on mastication and subjective outcomes. Copyright © 2012 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Quantification of Valleys of Randomly Textured Substrates as a Function of Opening Angle: Correlation to the Defect Density in Intrinsic nc-Si:H.

    PubMed

    Kim, Do Yun; Hänni, Simon; Schüttauf, Jan-Willem; van Swaaij, René A C M M; Zeman, Miro

    2016-08-17

    Optical and electrical properties of hydrogenated nanocrystalline silicon (nc-Si:H) solar cells are strongly influenced by the morphology of underlying substrates. By texturing the substrates, the photogenerated current of nc-Si:H solar cells can increase due to enhanced light scattering. These textured substrates are, however, often incompatible with defect-less nc-Si:H growth resulting in lower Voc and FF. In this study we investigate the correlation between the substrate morphology, the nc-Si:H solar-cell performance, and the defect density in the intrinsic layer of the solar cells (i-nc-Si:H). Statistical surface parameters representing the substrate morphology do not show a strong correlation with the solar-cell parameters. Thus, we first quantify the line density of potentially defective valleys of randomly textured ZnO substrates where the opening angle is smaller than 130° (ρ<130). This ρ<130 is subsequently compared with the solar-cell performance and the defect density of i-nc-Si:H (ρdefect), which is obtained by fitting external photovoltaic parameters from experimental results and simulations. We confirm that when ρ<130 increases the Voc and FF significantly drops. It is also observed that ρdefect increases following a power law dependence of ρ<130. This result is attributed to more frequently formed defective regions for substrates having higher ρ<130.

  9. Analysis of Defects in Trouser Manufacturing: Development of a Knowledge-Based Framework. Volume 1. Final Technical Report

    DTIC Science & Technology

    1992-02-28

    the primary goal of instituting remedial measures. Many apparel plants, as they function today in the United States, do not maintain an accu- rate...type of usage is the primary functional mode for FDAS. Alternatively, the user could suggest a defect to FDAS and let it find out if the defect is...Endeavor The primary objective of the research effort is to develop a knowledge-based system to an- alyze the causes of defects in apparel

  10. Identifying Structure-Property Relationships Through DREAM.3D Representative Volume Elements and DAMASK Crystal Plasticity Simulations: An Integrated Computational Materials Engineering Approach

    NASA Astrophysics Data System (ADS)

    Diehl, Martin; Groeber, Michael; Haase, Christian; Molodov, Dmitri A.; Roters, Franz; Raabe, Dierk

    2017-05-01

    Predicting, understanding, and controlling the mechanical behavior is the most important task when designing structural materials. Modern alloy systems—in which multiple deformation mechanisms, phases, and defects are introduced to overcome the inverse strength-ductility relationship—give raise to multiple possibilities for modifying the deformation behavior, rendering traditional, exclusively experimentally-based alloy development workflows inappropriate. For fast and efficient alloy design, it is therefore desirable to predict the mechanical performance of candidate alloys by simulation studies to replace time- and resource-consuming mechanical tests. Simulation tools suitable for this task need to correctly predict the mechanical behavior in dependence of alloy composition, microstructure, texture, phase fractions, and processing history. Here, an integrated computational materials engineering approach based on the open source software packages DREAM.3D and DAMASK (Düsseldorf Advanced Materials Simulation Kit) that enables such virtual material development is presented. More specific, our approach consists of the following three steps: (1) acquire statistical quantities that describe a microstructure, (2) build a representative volume element based on these quantities employing DREAM.3D, and (3) evaluate the representative volume using a predictive crystal plasticity material model provided by DAMASK. Exemplarily, these steps are here conducted for a high-manganese steel.

  11. Impaired Cell Volume Regulation in Intestinal Crypt Epithelia of Cystic Fibrosis Mice

    NASA Astrophysics Data System (ADS)

    Valverde, M. A.; O'Brien, J. A.; Sepulveda, F. V.; Ratcliff, R. A.; Evans, M. J.; Colledge, W. H.

    1995-09-01

    Cystic fibrosis is a disease characterized by abnormalities in the epithelia of the lungs, intestine, salivary and sweat glands, liver, and reproductive systems, often as a result of inadequate hydration of their secretions. The primary defect in cystic fibrosis is the altered activity of a cAMP-activated Cl^- channel, the cystic fibrosis transmembrane conductance regulator (CFTR) channel. However, it is not clear how a defect in the CFTR Cl^- channel function leads to the observed pathological changes. Although much is known about the structural properties and regulation of the CFTR, little is known of its relationship to cellular functions other than the cAMP-dependent Cl^- secretion. Here we report that cell volume regulation after hypotonic challenge is also defective in intestinal crypt epithelial cells isolated from CFTR -/- mutant mice. Moreover, the impairment of the regulatory volume decrease in CFTR -/- crypts appears to be related to the inability of a K^+ conductance to provide a pathway for the exit of this cation during the volume adjustments. This provides evidence that the lack of CFTR protein may have additional consequences for the cellular function other than the abnormal cAMP-mediated Cl^- secretion.

  12. Ontological Modeling of Transformation in Heart Defect Diagrams

    PubMed Central

    Viswanath, Venkatesh; Tong, Tuanjie; Dinakarpandian, Deendayal; Lee, Yugyung

    2006-01-01

    The accurate portrayal of a large volume data of variable heart defects is crucial to providing good patient care in pediatric cardiology. Our research aims to span the universe of congenital heart defects by generating illustrative diagrams that enhance data interpretation. To accommodate the range and severity of defects to be represented, we base our diagrams on transformation models applied to a normal heart rather than a static set of defects. These models are based on a domain-specific ontology, clustering, association rule mining and the use of parametric equations specified in a mathematical programming language. PMID:17238451

  13. Achiral symmetry breaking and positive Gaussian modulus lead to scalloped colloidal membranes

    PubMed Central

    Gibaud, Thomas; Kaplan, C. Nadir; Sharma, Prerna; Zakhary, Mark J.; Ward, Andrew; Oldenbourg, Rudolf; Meyer, Robert B.; Kamien, Randall D.; Powers, Thomas R.; Dogic, Zvonimir

    2017-01-01

    In the presence of a nonadsorbing polymer, monodisperse rod-like particles assemble into colloidal membranes, which are one-rod-length–thick liquid-like monolayers of aligned rods. Unlike 3D edgeless bilayer vesicles, colloidal monolayer membranes form open structures with an exposed edge, thus presenting an opportunity to study elasticity of fluid sheets. Membranes assembled from single-component chiral rods form flat disks with uniform edge twist. In comparison, membranes composed of a mixture of rods with opposite chiralities can have the edge twist of either handedness. In this limit, disk-shaped membranes become unstable, instead forming structures with scalloped edges, where two adjacent lobes with opposite handedness are separated by a cusp-shaped point defect. Such membranes adopt a 3D configuration, with cusp defects alternatively located above and below the membrane plane. In the achiral regime, the cusp defects have repulsive interactions, but away from this limit we measure effective long-ranged attractive binding. A phenomenological model shows that the increase in the edge energy of scalloped membranes is compensated by concomitant decrease in the deformation energy due to Gaussian curvature associated with scalloped edges, demonstrating that colloidal membranes have positive Gaussian modulus. A simple excluded volume argument predicts the sign and magnitude of the Gaussian curvature modulus that is in agreement with experimental measurements. Our results provide insight into how the interplay between membrane elasticity, geometrical frustration, and achiral symmetry breaking can be used to fold colloidal membranes into 3D shapes. PMID:28411214

  14. Study of Silicon/silicon, Silicon/silicon Dioxide, and Metal-Oxide

    NASA Astrophysics Data System (ADS)

    Leung, To Chi

    A variable-energy positron beam is used to study Si/Si, Si/SiO_2, and metal-oxide -semiconductor (MOS) structures. The capability of depth resolution and the remarkable sensitivity to defects have made the positron annihilation technique a unique tool in detecting open-volume defects in the newly innovated low temperature (300^circC) molecular-beam-epitaxy (MBE) Si/Si. These two features of the positron beam have further shown its potential role in the study of the Si/SiO_2. Distinct annihilation characteristics has been observed at the interface and has been studied as a function of the sample growth conditions, annealing (in vacuum), and hydrogen exposure. The MOS structure provides an effective way to study the electrical properties of the Si/SiO_2 interface as a function of applied bias voltage. The annihilation characteristics show a large change as the device condition is changed from accumulation to inversion. The effect of forming gas (FG) anneal is studied using positron annihilation and the result is compared with capacitance-voltage (C -V) measurements. The reduction in the number of interface states is found correlated with the changes in the positron spectra. The present study shows the importance of the positron annihilation technique as a non-contact, non-destructive, and depth-sensitive characterization tool to study the Si-related systems, in particular, the Si/SiO_2 interface which is of crucial importance in semiconductor technology, and fundamental understanding of the defects responsible for degradation of the electrical properties.

  15. Imperforate anus repair

    MedlinePlus

    ... anus defects: The first surgery is called a colostomy . The surgeon creates an opening (stoma) in the ... into place and create an anal opening. The colostomy will likely be left in place for 2 ...

  16. Use of overburden rocks from open-pit coal mines and waste coals of Western Siberia for ceramic brick production with a defect-free structure

    NASA Astrophysics Data System (ADS)

    Stolboushkin, A. Yu; Ivanov, A. I.; Storozhenko, G. I.; Syromyasov, V. A.; Akst, D. V.

    2017-09-01

    The rational technology for the production of ceramic bricks with a defect-free structure from coal mining and processing wastes was developed. The results of comparison of physical and mechanical properties and the structure of ceramic bricks manufactured from overburden rocks and waste coal with traditional for semi-dry pressing mass preparation and according to the developed method are given. It was established that a homogeneous, defect-free brick texture obtained from overburden rocks of open-pit mines and waste coal improves the quality of ceramic wall materials produced by the method of compression molding by more than 1.5 times compared to the brick with a traditional mass preparation.

  17. Rapid transitions between defect configurations in a block copolymer melt.

    PubMed

    Tsarkova, Larisa; Knoll, Armin; Magerle, Robert

    2006-07-01

    With in situ scanning force microscopy, we image the ordering of cylindrical microdomains in a thin film of a diblock copolymer melt. Tracking the evolution of individual defects reveals elementary steps of defect motion via interfacial undulations and repetitive transitions between distinct defect configurations on a time scale of tens of seconds. The velocity of these transitions suggests a cooperative movement of clusters of chains. The activation energy for the opening/closing of a connection between two cylinders is estimated.

  18. On the development of weighting factors for ballast ranking prioritization & development of the relationship and rate of defective segments based on volume of missing ballast

    NASA Astrophysics Data System (ADS)

    Cronin, John

    This thesis explores the effects of missing ballast on track behavior and degradation. As ballast is an integral part of the track structure, the hypothesized effect of missing ballast is that defects will be more common which in turn leads to more derailments. In order to quantify the volume of missing ballast, remote sensing technologies were used to provide an accurate profile of the ballast. When the existing profile is compared to an idealized profile, the area of missing ballast can be computed. The area is then subdivided into zones which represent the area in which the ballast performs a key function in the track structure. These areas are then extrapolated into the volume of missing ballast for each zone based on the distance between collected profiles. In order to emphasize the key functions that the zones previously created perform, weighting factors were developed based on common risk-increasing hazards, such as curves and heavy axle loads, which are commonly found on railways. These weighting factors are applied to the specified zones' missing ballast volume when such a hazard exists in that segment of track. Another set of weighting factors were developed to represent the increased risk, or preference for lower risk, for operational factors such as the transport of hazardous materials or for being a key route. Through these weighting factors, ballast replenishment can be prioritized to focus on the areas that pose a higher risk of derailments and their associated costs. For the special cases where the risk or aversion to risk comes from what is being transported, such as the case with hazardous materials or passengers, an economic risk assessment was completed in order to quantify the risk associated with their transport. This economic risk assessment looks at the increased costs associated with incidents that occur and how they compare to incidents which do not directly involve the special cargos. In order to provide support for the use of the previously developed weightings as well as to quantify the actual impact that missing ballast has on the rate of geometry defects, analyses which quantified the risk of missing ballast were performed. In addition to quantifying the rate of defects, analyses were performed which looked at the impact associated with curved track, how the location of missing ballast impacts the rate of geometry defects and how the combination of the two compared with the previous analyses. Through this research, the relationship between the volume of missing ballast and ballast-related defects has been identified and quantified. This relationship is positive for the aggregate of all ballast-related defects but does not always exist for individual defects which occasionally have unique behavior. For the non-ballast defects, a relationship between missing ballast and their rate of occurrence did not always appear to exist. The impact of curves was apparent, showing that the rate of defects was either similar to or exceeded the rate of defects for tangent track. For the analyses which looked at the location of ballast in crib or shoulder, the results were quite similar to the previous analyses. The development, application and improvements of a risk-based ballast maintenance prioritization system provides a relatively low-cost and effective method to improve the operational safety for all railroads.

  19. Achieving Radiation Tolerance through Non-Equilibrium Grain Boundary Structures.

    PubMed

    Vetterick, Gregory A; Gruber, Jacob; Suri, Pranav K; Baldwin, Jon K; Kirk, Marquis A; Baldo, Pete; Wang, Yong Q; Misra, Amit; Tucker, Garritt J; Taheri, Mitra L

    2017-09-25

    Many methods used to produce nanocrystalline (NC) materials leave behind non-equilibrium grain boundaries (GBs) containing excess free volume and higher energy than their equilibrium counterparts with identical 5 degrees of freedom. Since non-equilibrium GBs have increased amounts of both strain and free volume, these boundaries may act as more efficient sinks for the excess interstitials and vacancies produced in a material under irradiation as compared to equilibrium GBs. The relative sink strengths of equilibrium and non-equilibrium GBs were explored by comparing the behavior of annealed (equilibrium) and as-deposited (non-equilibrium) NC iron films on irradiation. These results were coupled with atomistic simulations to better reveal the underlying processes occurring on timescales too short to capture using in situ TEM. After irradiation, NC iron with non-equilibrium GBs contains both a smaller number density of defect clusters and a smaller average defect cluster size. Simulations showed that excess free volume contribute to a decreased survival rate of point defects in cascades occurring adjacent to the GB and that these boundaries undergo less dramatic changes in structure upon irradiation. These results suggest that non-equilibrium GBs act as more efficient sinks for defects and could be utilized to create more radiation tolerant materials in future.

  20. Heavy Lift Helicopter Flight Control System. Volume III. Automatic Flight Control System Development and Feasibility Demonstration

    DTIC Science & Technology

    1977-09-01

    vdI1 SCCLRITY CLASSIFICATIOlN OF THIS PAGE(When DMae ffnifod) Block 20 (Cont): ------ AFCS control laws are examined. Associated documents are: Volume I...both the HII gain and LO gain outputs. Both were traced to defective components. In the former, the HII gain output amplifier AR4 was replaced and in...the latter, a relay in the relay module was defective . 613 S. . ......-. . . 6.2.2.4 ExcessivC Time Lag During the BARO altitude hold evaluation, the

  1. A computational framework for automation of point defect calculations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goyal, Anuj; Gorai, Prashun; Peng, Haowei

    We have developed a complete and rigorously validated open-source Python framework to automate point defect calculations using density functional theory. Furthermore, the framework provides an effective and efficient method for defect structure generation, and creation of simple yet customizable workflows to analyze defect calculations. This package provides the capability to compute widely-accepted correction schemes to overcome finite-size effects, including (1) potential alignment, (2) image-charge correction, and (3) band filling correction to shallow defects. Using Si, ZnO and In2O3 as test examples, we demonstrate the package capabilities and validate the methodology.

  2. A computational framework for automation of point defect calculations

    DOE PAGES

    Goyal, Anuj; Gorai, Prashun; Peng, Haowei; ...

    2017-01-13

    We have developed a complete and rigorously validated open-source Python framework to automate point defect calculations using density functional theory. Furthermore, the framework provides an effective and efficient method for defect structure generation, and creation of simple yet customizable workflows to analyze defect calculations. This package provides the capability to compute widely-accepted correction schemes to overcome finite-size effects, including (1) potential alignment, (2) image-charge correction, and (3) band filling correction to shallow defects. Using Si, ZnO and In2O3 as test examples, we demonstrate the package capabilities and validate the methodology.

  3. Confocal Raman imaging of optical waveguides in LiNbO3 fabricated by ultrafast high-repetition rate laser-writing.

    PubMed

    Ródenas, Airán; Nejadmalayeri, Amir H; Jaque, Daniel; Herman, Peter

    2008-09-01

    We report on the confocal Raman characterization of the micro-structural lattice changes induced during the high-repetition rate ultrafast laser writing of buried optical waveguides in lithium niobate (LiNbO(3)) crystals. While the laser beam focal volume is characterized by a significant lattice expansion together with a high defect concentration, the adjacent waveguide zone is largely free of defects, undergoing only slight rearrangement of the oxygen octahedron in the LiNbO(3) lattice. The close proximity of these two zones has been found responsible for the propagation losses of the guided light. Subjacent laser-induced periodic micro-structures have been also observed inside the laser focal volume, and identified with a strong periodic distribution of lattice defects.

  4. Selection and Characterization of Dunaliella salina Mutants Defective in Haloadaptation 1

    PubMed Central

    Chitlaru, Edith; Pick, Uri

    1989-01-01

    A technique for selection of Dunaliella mutants defective in their capacity to recover from osmotic shocks has been developed. The selection is based on physical separation of mutants on density gradients. This technique takes advantage of the fact that Dunaliella cells, when exposed to osmotic shocks, initially change volume and density due to water gain or loss and subsequently recover their volume and density by readjusting their intracellular glycerol. Eight mutants that do not recover their original density following hyperosmotic shocks have been isolated. The mutants grow similar to wild type cells in 1 molar NaCl, and recover like the wild type from hypotonic shocks but are defective in recovering from hypertonic shocks. A partial characterization of one of the mutants is described. Images Figure 1 PMID:16667101

  5. Clinical and radiographic evaluation of intrabony periodontal defect treatment by open flap debridement alone or in combination with nanocrystalline hydroxyapatite bone substitute.

    PubMed

    Pietruska, Małgorzata; Skurska, Anna; Pietruski, Jan; Dolińska, Ewa; Arweiler, Nicole; Milewski, Robert; Duraj, Ewa; Sculean, Anton

    2012-11-01

    The aim of this study has been to compare the clinical and radiographic outcome of periodontal intrabony defect treatment by open flap debridement alone or in combination with nanocrystalline hydroxyapatite bone substitute application. Thirty patients diagnosed with advanced periodontits were divided into two groups: the control group (OFD), in which an open flap debridement procedure was performed and the test group (OFD+NHA), in which defects were additionally filled with nanocrystalline hydroxyapatite bone substitute material. Plaque index (PI), gingival index (GI), bleeding on probing (BOP), pocket depth (PD), gingival recession (GR) and clinical attachment level (CAL) were measured prior to, then 6 and 12months following treatment. Radiographic depth and width of defects were also evaluated. There were no differences in any clinical and radiographic parameters between the examined groups prior to treatment. After treatment, BOP, GI, PD, CAL, radiographic depth and width parameter values improved statistically significantly in both groups. The PI value did not change, but the GR value increased significantly after treatment. There were no statistical differences in evaluated parameters between OFD and OFD+NHA groups 6 and 12months after treatment. Within the limits of the study, it can be concluded that the additional use of nanocrystalline hydroxyapatite bone substitute material after open flap procedure does not improve clinical and radiographic treatment outcome. Copyright © 2012 Elsevier GmbH. All rights reserved.

  6. Changing the surgical dogma in frontal sinus trauma: transnasal endoscopic repair.

    PubMed

    Grayson, Jessica W; Jeyarajan, Hari; Illing, Elisa A; Cho, Do-Yeon; Riley, Kristen O; Woodworth, Bradford A

    2017-05-01

    Management of frontal sinus trauma includes coronal or direct open approaches through skin incisions to either ablate or obliterate the frontal sinus for posterior table fractures and openly reduce/internally fixate fractured anterior tables. The objective of this prospective case-series study was to evaluate outcomes of frontal sinus anterior and posterior table trauma using endoscopic techniques. Prospective evaluation of patients undergoing surgery for frontal sinus fractures was performed. Data were collected regarding demographics, etiology, technique, operative site, length involving the posterior table, size of skull base defects, complications, and clinical follow-up. Forty-six patients (average age, 42 years) with frontal sinus fractures were treated using endoscopic techniques from 2008 to 2016. Mean follow-up was 26 (range, 0.5 to 79) months. Patients were treated primarily with a Draf IIb frontal sinusotomies. Draf III was used in 8 patients. Average fracture defect (length vs width) was 17.1 × 9.1 mm, and the average length involving the posterior table was 13.1 mm. Skull base defects were covered with either nasoseptal flaps or free tissue grafts. One individual required Draf IIb revision, but all sinuses were patent on final examination and all closed reductions of anterior table defects resulted in cosmetically acceptable outcomes. Frontal sinus trauma has traditionally been treated using open approaches. Our findings show that endoscopic management should become part of the management algorithm for frontal sinus trauma, which challenges current surgical dogma regarding mandatory open approaches. © 2017 ARS-AAOA, LLC.

  7. Robot-assisted versus open radical prostatectomy: the differential effect of regionalization, procedure volume and operative approach.

    PubMed

    Sammon, Jesse D; Karakiewicz, Pierre I; Sun, Maxine; Sukumar, Shyam; Ravi, Praful; Ghani, Khurshid R; Bianchi, Marco; Peabody, James O; Shariat, Shahrokh F; Perrotte, Paul; Hu, Jim C; Menon, Mani; Trinh, Quoc-Dien

    2013-04-01

    The use of robot-assisted radical prostatectomy has increased rapidly despite the absence of randomized, controlled trials showing the superiority of this approach. While recent studies suggest an advantage for perioperative complication rates, they fail to account for the volume-outcome relationship. We compared perioperative outcomes after robot-assisted and open radical prostatectomy, while considering the impact of this established relationship. Using the NIS (Nationwide Inpatient Sample), we abstracted data on patients treated with radical prostatectomy in 2009. Univariable and multivariable logistic regression analyses were done to compare the rates of blood transfusion, intraoperative and postoperative complications, prolonged length of stay, increased hospital charges and mortality between robot-assisted and open radical prostatectomy overall and across volume quartiles. An estimated 77,616 men underwent radical prostatectomy, including a robot-assisted and an open procedure in 63.9% and 36.1%, respectively. Low volume centers averaged 26.2 robot-assisted and 5.2 open cases, while very high volume centers averaged 578.8 robot-assisted and 150.2 open cases. Overall, patients treated with the robot-assisted procedure experienced a lower rate of adverse outcomes than those treated with the open procedure for all measured categories. Across equivalent volume quartiles robot-assisted radical prostatectomy outcomes were generally favorable. However, the open procedure at high volume centers resulted in a lower postoperative complication rate (OR 0.59, 95% CI 0.46-0.75), elevated hospital charges (OR 0.75, 95% CI 0.64-0.87) and a comparable blood transfusion rate (OR 1.38, 95% CI 0.93-2.02) relative to the robot-assisted procedure at low volume centers. Regionalization has occurred to a greater extent for robot-assisted than for open radical prostatectomy with an associated benefit in overall outcomes. Nonetheless, low volume institutions experienced inferior outcomes relative to the highest volume centers irrespective of approach. These findings demonstrate the importance of accounting for hospital volume when examining the benefit of a surgical technique. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. An improved method for characterizing photoresist lithographic and defectivity performance for sub-20nm node lithography

    NASA Astrophysics Data System (ADS)

    Amblard, Gilles; Purdy, Sara; Cooper, Ryan; Hockaday, Marjory

    2016-03-01

    The overall quality and processing capability of lithographic materials are critical for ensuring high device yield and performance at sub-20nm technology nodes in a high volume manufacturing environment. Insufficient process margin and high line width roughness (LWR) cause poor manufacturing control, while high defectivity causes product failures. In this paper, we focus on the most critical layer of a sub-20nm technology node LSI device, and present an improved method for characterizing both lithographic and post-patterning defectivity performance of state-of-the-art immersion photoresists. Multiple formulations from different suppliers were used and compared. Photoresists were tested under various process conditions, and multiple lithographic metrics were investigated (depth of focus, exposure dose latitude, line width roughness, etc.). Results were analyzed and combined using an innovative approach based on advanced software, providing clearer results than previously available. This increased detail enables more accurate performance comparisons among the different photoresists. Post-patterning defectivity was also quantified, with defects reviewed and classified using state-of-the-art inspection tools. Correlations were established between the lithographic and post-patterning defectivity performances for each material, and overall ranking was established among the photoresists, enabling the selection of the best performer for implementation in a high volume manufacturing environment.

  9. Non-destructive Detection of Screw Dislocations and the Corresponding Defects Nucleated from Them During SiC Epitaxial Growth and Their Effect on Device Characteristics

    NASA Astrophysics Data System (ADS)

    Das, H.; Sunkari, S.; Naas, H.

    2018-06-01

    In high-volume manufacturing of SiC power devices like Schottky barrier diodes and MOSFETs, especially with the high demands of high reliability applications like the automotive market, the issue of reliability needs to be tackled from multiple angles. It becomes important to isolate and eliminate failure mechanisms at the source rather than just rely on electrical tests. As we enter volume production on 150-mm substrates, an added layer of reliability and improved yield can be added if potential sources of defects are identified and removed. In this work, we present the non-destructive detection of a subset of screw dislocations in N+ doped substrates, trace the preferential nucleation of V-type epitaxial defects and stacking faults from these screw dislocations, and study their electrical effects on Schottky diodes. This enables the screening of highly defective substrates even before committing them to epitaxial growth.

  10. Biomechanical stability of novel mechanically adapted open-porous titanium scaffolds in metatarsal bone defects of sheep.

    PubMed

    Wieding, Jan; Lindner, Tobias; Bergschmidt, Philipp; Bader, Rainer

    2015-04-01

    Open-porous titanium scaffolds for large segmental bone defects offer advantages like early weight-bearing and limited risk of implant failure. The objective of this experimental study was to determine the biomechanical behavior of novel open-porous titanium scaffolds with mechanical-adapted properties in vivo. Two types of the custom-made, open-porous scaffolds made of Ti6Al4V (Young's modulus: 6-8 GPa and different pore sizes) were implanted into a 20 mm segmental defect in the mid-diaphysis of the metatarsus of sheep, and were stabilized with an osteosynthesis plate. After 12 and 24 weeks postoperatively, torsional testing was performed on the implanted bone and compared to the contralateral non-treated side. Maximum torque, maximum angle, torsional stiffness, fracture energy, shear modulus and shear stress were investigated. Furthermore, bone mineral density (BMD) of the newly formed bone was determined. Mechanical loading capabilities for both scaffolds were similar and about 50% after 12 weeks (e.g., max. torque of approximately 20 Nm). A further increase after 24 weeks was found for most of the investigated parameters. Results for torsional stiffness and shear modulus as well as bone formation depended on the type of scaffold. Increased BMD after 24 weeks was found for one scaffold type but remained constant for the other one. The present data showed the capability of mechanically adapted open-porous titanium scaffolds to function as bone scaffolds for large segmental defects and the influence of the scaffold's stiffness. A further increase in the biomechanical stability can be assumed for longer observation periods of greater than six months. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Imperforate anus repair - series (image)

    MedlinePlus

    ... a high type imperforate anus defect usually involves creation of a temporary opening of the large intestine ( ... includes a fistula) involves closure of the fistula, creation of an anal opening, and repositioning the rectal ...

  12. Long-term Observation of Regenerated Periodontium Induced by FGF-2 in the Beagle Dog 2-Wall Periodontal Defect Model

    PubMed Central

    Anzai, Jun; Nagayasu-Tanaka, Toshie; Terashima, Akio; Asano, Taiji; Yamada, Satoru; Nozaki, Takenori; Kitamura, Masahiro; Murakami, Shinya

    2016-01-01

    The long-term stability and qualitative characteristics of periodontium regenerated by FGF-2 treatment were compared with normal physiological healing tissue controls in a Beagle dog 2-wall periodontal defect model 13 months after treatment by assessing tissue histology and three-dimensional microstructure using micro-computed tomography (μCT). After FGF-2 (0.3%) or vehicle treatment at the defect sites, serial changes in the bone mineral content (BMC) were observed using periodic X-ray imaging. Tissues were harvested at 13 months, evaluated histomorphometrically, and the cortical bone volume and trabecular bone structure of the newly formed bone were analyzed using μCT. FGF-2 significantly increased the BMC of the defect area at 2 months compared with that of the control group, and this difference was unchanged through 13 months. The cortical bone volume was significantly increased by FGF-2, but there was no difference between the groups in trabecular bone structure. Bone maturation was occurring in both groups because of the lower cortical volume and denser trabecular bone than what is found in intact bone. FGF-2 also increased the area of newly formed bone as assessed histomorphometrically, but the ratios of trabecular bone in the defect area were similar between the control and FGF-2 groups. These results suggest that FGF-2 stimulates neogenesis of alveolar bone that is of similar quality to that of the control group. The lengths of the regenerated periodontal ligament and cementum, measured as the distance from the defect bottom to the apical end of the gingival epithelium, and height and area of the newly formed bone in the FGF-2 group were larger than those in the control group. The present study demonstrated that, within the limitation of artificial periodontal defect model, the periodontal tissue regenerated by FGF-2 was maintained for 13 months after treatment and was qualitatively equivalent to that generated through the physiological healing process. PMID:27391131

  13. Improving observational study estimates of treatment effects using joint modeling of selection effects and outcomes: the case of AAA repair.

    PubMed

    O'Malley, A James; Cotterill, Philip; Schermerhorn, Marc L; Landon, Bruce E

    2011-12-01

    When 2 treatment approaches are available, there are likely to be unmeasured confounders that influence choice of procedure, which complicates estimation of the causal effect of treatment on outcomes using observational data. To estimate the effect of endovascular (endo) versus open surgical (open) repair, including possible modification by institutional volume, on survival after treatment for abdominal aortic aneurysm, accounting for observed and unobserved confounding variables. Observational study of data from the Medicare program using a joint model of treatment selection and survival given treatment to estimate the effects of type of surgery and institutional volume on survival. We studied 61,414 eligible repairs of intact abdominal aortic aneurysms during 2001 to 2004. The outcome, perioperative death, is defined as in-hospital death or death within 30 days of operation. The key predictors are use of endo, transformed endo and open volume, and endo-volume interactions. There is strong evidence of nonrandom selection of treatment with potential confounding variables including institutional volume and procedure date, variables not typically adjusted for in clinical trials. The best fitting model included heterogeneous transformations of endo volume for endo cases and open volume for open cases as predictors. Consistent with our hypothesis, accounting for unmeasured selection reduced the mortality benefit of endo. The effect of endo versus open surgery varies nonlinearly with endo and open volume. Accounting for institutional experience and unmeasured selection enables better decision-making by physicians making treatment referrals, investigators evaluating treatments, and policy makers.

  14. Simulation and Analysis of Electric Field for the Disconnector Switch Incomplete Opening Position Based on 220kV GIS

    NASA Astrophysics Data System (ADS)

    Wang, Feifeng; Huang, Huimin; Su, Yi; Yan, Dandan; Lu, Yufeng; Xia, Xiaofei; Yang, Jian

    2018-05-01

    It has accounted for a large proportion of GIS equipment defects, which cause the disconnector switches to incomplete open-close position. Once opening operation is not in place, it will arouse continuous arcing between contacts to reduce insulation strength. Otherwise, the intense heat give rise to burn the contact, which has a severe effect on the safe operation of power grid. This paper analyzes some typical defection cases about the opening operation incomplete for disconnector switches of GIS. The COMSOL Multiphysics is applied to verify the influence on electric field distribution. The results show that moving contact out shield is 20 mm, the electric field distribution of the moving contact surface is uneven, and the maximum electric field value can reach 9.74 kV/mm.

  15. The Long-Term Clinical Outcomes Following Autogenous Bone Grafting for Large-Volume Defects of the Knee

    PubMed Central

    Delano, Mark; Spector, Myron; Pittsley, Andrew; Gottschalk, Alexander

    2014-01-01

    Objective: We report the long-term clinical outcomes of patients who underwent autogenous bone grafting of large-volume osteochondral defects of the knee due to osteochondritis dessicans (OCD) and osteonecrosis (ON). This is the companion report to one previous published on the biological response. We hypothesized that these grafts would integrate with host bone and the articular surface would form fibrocartilage providing an enduring clinical benefit. Design: Three groups (patients/knees) were studied: OCD without a fragment (n = 12/13), OCD with a partial fragment (n = 14/16), and ON (n = 25/26). Twenty-five of 52 patients were available for clinical follow-up between 12 and 21 years. Electronic medical records provided comparison clinical information. In addition, there were plain film radiographs, MRIs, plus repeat arthroscopy and biopsy on 14 patients. Results: Autogenous bone grafts integrated with the host bone. MRI showed soft tissue covering all the grafts at long-term follow-up. Biopsy showed initial surface fibrocartilage that subsequently converted to fibrocartilage and hyaline cartilage at 20 years. OCD patients had better clinical outcomes than ON patients. No OCD patients were asymptomatic at anytime following surgery. Half of the ON patients came to total knee replacement within 10 years. Conclusions: Autogenous bone grafting provides an alternative biological matrix to fill large-volume defects in the knee as a singular solution integrating with host bone and providing an enduring articular cartilage surface. The procedure is best suited for those with OCD. The treatment for large-volume articular defects by this method remains salvage in nature and palliative in outcome. PMID:26069688

  16. Association Between Infrapatellar Fat Pad Volume and Knee Structural Changes in Patients with Knee Osteoarthritis.

    PubMed

    Cai, Jingyu; Xu, Jianhua; Wang, Kang; Zheng, Shuang; He, Fan; Huan, Shuting; Xu, Shengqing; Zhang, Hui; Laslett, Laura; Ding, Changhai

    2015-10-01

    The function of the infrapatellar fat pad (IPFP) in knee osteoarthritis (OA) remains uncertain. This study aimed to examine cross-sectional associations between IPFP volume and knee structures in patients with knee OA. The study included 174 patients with clinical knee OA (mean age, 55.5 yrs). Fat-suppressed 3-D T1-weighted spoiled gradient recall magnetic resonance imaging (MRI) was used to measure the IPFP and cartilage volume. T2-weighted fast spin echo MRI was used to assess cartilage defects and bone marrow lesions (BML). Radiographic knee osteophytes and joint space narrowing (JSN) were assessed using the Osteoarthritis Research Society International atlas. After adjustment for potential confounders, greater IPFP volume was associated with greater tibial and patellar cartilage volume (all p < 0.05), and fewer cartilage defects at all sites (OR 0.88-0.91, all p < 0.05). IPFP volume was associated with presence of BML at lateral tibial and medial femoral sites (OR 0.88-0.91, all p < 0.05) and osteophytes at lateral tibiofemoral compartment (OR 0.88, p < 0.05). IPFP volume was not significantly associated with JSN. Greater IPFP volume was associated with greater knee cartilage volume and fewer structural abnormalities, suggesting a protective role of IPFP size in knee OA.

  17. Electric-dipole effect of defects on the energy band alignment of rutile and anatase TiO₂.

    PubMed

    Zhang, Daoyu; Yang, Minnan; Dong, Shuai

    2015-11-21

    Titanium dioxide materials have been studied intensively and extensively for photocatalytic applications. A long-standing open question is the energy band alignment of rutile and anatase TiO2 phases, which can affect the photocatalytic process in the composite system. There are basically two contradictory viewpoints about the alignment of these two TiO2 phases supported by the respective experiments: (1) straddling type and (2) staggered type. In this work, our DFT plus U calculations show that the perfect rutile(110) and anatase(101) surfaces have the straddling type band alignment, whereas the surfaces with defects can turn the band alignment into the staggered type. The electric dipoles induced by defects are responsible for the reversal of band alignment. Thus the defects introduced during the preparation and post-treatment processes of materials are probably the answer to the above open question regarding the band alignment, which can be considered in real practice to tune the photocatalytic activity of materials.

  18. Application of Morphological Segmentation to Leaking Defect Detection in Sewer Pipelines

    PubMed Central

    Su, Tung-Ching; Yang, Ming-Der

    2014-01-01

    As one of major underground pipelines, sewerage is an important infrastructure in any modern city. The most common problem occurring in sewerage is leaking, whose position and failure level is typically idengified through closed circuit television (CCTV) inspection in order to facilitate rehabilitation process. This paper proposes a novel method of computer vision, morphological segmentation based on edge detection (MSED), to assist inspectors in detecting pipeline defects in CCTV inspection images. In addition to MSED, other mathematical morphology-based image segmentation methods, including opening top-hat operation (OTHO) and closing bottom-hat operation (CBHO), were also applied to the defect detection in vitrified clay sewer pipelines. The CCTV inspection images of the sewer system in the 9th district, Taichung City, Taiwan were selected as the experimental materials. The segmentation results demonstrate that MSED and OTHO are useful for the detection of cracks and open joints, respectively, which are the typical leakage defects found in sewer pipelines. PMID:24841247

  19. Echocardiographic diagnosis of left ventricular-right atrial communication (Gerbode-type defect) in an adult with chronic renal failure: a case report.

    PubMed

    Eroglu, Serpil; Sade, Elif; Bozbas, Huseyin; Pirat, Bahar; Yildirir, Aylin; Muderrisoglu, Haldun

    2008-03-01

    Left ventricular-right atrial communication, known as a Gerbode-type defect, is a rare form of ventricular septal defect. It is usually congenital, but rarely acquired. Clinical presentation is associated with the volume of the shunt. Transthoracic echocardiography is the most useful diagnostic method. We present a 63-year-old man with chronic renal failure and left ventricular-right atrial shunt.

  20. The effect of laparotomy and external fixator stabilization on pelvic volume in an unstable pelvic injury.

    PubMed

    Ghanayem, A J; Wilber, J H; Lieberman, J M; Motta, A O

    1995-03-01

    Determine if laparotomy further destabilizes an unstable pelvic injury and increases pelvic volume, and if reduction and stabilization restores pelvic volume and prevents volume changes secondary to laparotomy. Cadaveric pelvic fracture model. Unilateral open-book pelvic ring injuries were created in five fresh cadaveric specimens by directly disrupting the pubic symphysis, left sacroliac joint, and sacrospinous and sacrotuberous ligaments. Pelvic volume was determined using computerized axial tomography for the intact pelvis, disrupted pelvis with both a laparotomy incision opened and closed, and disrupted pelvis stabilized and reduced using an external fixator with the laparotomy incision opened. The average volume increase in the entire pelvis (from the top of the iliac crests to the bottom of the ischial tuberosities) between a nonstabilized injury with the abdomen closed and then subsequently opened was 15 +/- 5% (423 cc). The average increase in entire pelvic volume between a stabilized and reduced pelvis and nonstabilized pelvis, both with the abdomen open, was 26 +/- 5% (692 cc). The public diastasis increased from 3.9 to 9.3 cm in a nonstabilized pelvis with the abdomen closed and then subsequently opened. Application of a single-pin anterior-frame external fixator reduced the pubic diastasis anatomically and reduced the average entire and true (from the pelvic brim to the ischeal tuberosities) pelvic volumes to within 3 +/- 4 and 8 +/- 6% of the initial volume, respectively. We believe that the abdominal wall provides stability to an unstable pelvic ring injury via a tension band effect on the iliac wings. Our results demonstrate that a laparotomy further destabilized an open-book pelvic injury and subsequently increased pelvic volume and pubic diastasis. This could potentially increase blood loss from the pelvic injury and delay the tamponade effect of reduction and stabilization. A single-pin external fixator prevents the destabilizing effect of the laparotomy and effectively reduces pelvic volume. These data support reduction and temporary stabilization of unstable pelvic injuries before or concomitantly with laparotomy.

  1. Betaine supplementation reduces congenital defects after prenatal alcohol exposure (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Karunamuni, Ganga; Gu, Shi; Doughman, Yong Qiu; Sheehan, Megan M.; Ma, Pei; Peterson, Lindsy M.; Linask, Kersti K.; Jenkins, Michael W.; Rollins, Andrew M.; Watanabe, Michiko

    2016-03-01

    Over 500,000 women per year in the United States drink during pregnancy, and 1 in 5 of this population also binge drink. As high as 20-50% of live-born children with prenatal alcohol exposure (PAE) present with congenital heart defects including outflow and valvuloseptal anomalies that can be life-threatening. Previously we established a model of PAE (modeling a single binge drinking episode) in the avian embryo and used optical coherence tomography (OCT) imaging to assay early-stage cardiac function/structure and late-stage cardiac defects. At early stages, alcohol/ethanol-exposed embryos had smaller cardiac cushions and increased retrograde flow. At late stages, they presented with gross morphological defects in the head and chest wall, and also exhibited smaller or abnormal atrio-ventricular (AV) valves, thinner interventricular septae (IVS), and smaller vessel diameters for the aortic trunk branches. In other animal models, the methyl donor betaine (found naturally in many foods such as wheat bran, quinoa, beets and spinach) ameliorates neurobehavioral deficits associated with PAE but the effects on heart structure are unknown. In our model of PAE, betaine supplementation led to a reduction in gross structural defects and appeared to protect against certain types of cardiac defects such as ventricular septal defects and abnormal AV valvular morphology. Furthermore, vessel diameters, IVS thicknesses and mural AV leaflet volumes were normalized while the septal AV leaflet volume was increased. These findings highlight the importance of betaine and potentially methylation levels in the prevention of PAE-related birth defects which could have significant implications for public health.

  2. ALPS- A potential new automated lumber processing system

    Treesearch

    Charles W. McMillin; Richard W. Conners; Henry A. Huber

    1984-01-01

    During conventional production of solid wood furniture parts, logs are first sawed into lumber having defects randomly located throughout the board. The lumber is then remanufactured and the defects removed by ripping and crosscutting. The process is labor intensive, and saw kerf losses alone waste substantial volumes of lumber.

  3. Digital volume tomography in the diagnosis of peri-implant defects: an in vitro study on native pig mandibles.

    PubMed

    Mengel, Reiner; Kruse, Björn; Flores-de-Jacoby, Lavin

    2006-07-01

    The aim of this study of native pig mandibles was to investigate the accuracy and quality of the representation of peri-implant defects by intraoral radiography (IR), panoramic radiography (PR), computer tomography (CT), and digital volume tomography (DVT). The examination was carried out on 19 native pig mandibles. In the toothless sections of the mandibles, one or two implants were inserted. Following the standardized preparation of peri-implant defects (11 each of dehiscences, fenestrations, and 2- to 3-walled intrabony defects), IR, PR, CT, and DVT were performed. The peri-implant defects were measured using appropriate software on the digitized IR and PR image programs. As a control method, the peri-implant bone defects were measured directly using a reflecting stereomicroscope with measuring ocular. The statistical comparison between the measurements of the radiographic scans and those of the direct readings of the peri-implant defects was performed with Pearson's correlation coefficient. The quality of the radiographic scans was determined through the subjective perception and detectability of the peri-implant defects by five independent observers. In the DVT and CT scans, it was possible to measure all the bone defects in three planes. Comparison with the direct peri-implant defect measurements yielded a mean deviation of 0.17+/-0.11 mm for the DVT scans and 0.18+/-0.12 mm for the CT scans. On the IR and PR images, the defects could be detected only in the mesio-distal and cranio-caudal planes. In comparison with the direct measurements of the peri-implant defects, the IR images revealed a mean deviation of 0.34+/-0.30 mm, and the PR images revealed a mean deviation of 0.41+/-0.35 mm. The quality rating of the radiographic images was highest for the DVT scans. Overall, the CT and DVT scans displayed only a slight deviation in the extent of the peri-implant defects. Both radiographic imaging techniques permitted imaging of peri-implant defects in three planes, true to scale, and without overlay or distortion. The DVT scans showed the best imaging quality.

  4. Changes in down dead wood volume across a chronosequence of silvicultural openings in southern Indiana forests

    Treesearch

    Michael A. Jenkins; George R. Parker

    1997-01-01

    The volume and decay stages of down dead wood were evaluated across a chronosequence of 46 silvicultural openings and 10 uncut control stands to determine how down dead wood volume changes with stand development. Openings ranged in age from 8 to 26 years and were divided into three age groups: (1) 16 years. Individual logs...

  5. Three-dimensional characterization and distribution of fabrication defects in bilayered lithium disilicate glass-ceramic molar crowns.

    PubMed

    Jian, Yutao; He, Zi-Hua; Dao, Li; Swain, Michael V; Zhang, Xin-Ping; Zhao, Ke

    2017-04-01

    To investigate and characterize the distribution of fabrication defects in bilayered lithium disilicate glass-ceramic (LDG) crowns using micro-CT and 3D reconstruction. Ten standardized molar crowns (IPS e.max Press; Ivoclar Vivadent) were fabricated by heat-pressing on a core and subsequent manual veneering. All crowns were scanned by micro-CT and 3D reconstructed. Volume, position and sphericity of each defect was measured in every crown. Each crown was divided into four regions-central fossa (CF), occlusal fossa (OF), cusp (C) and axial wall (AW). Porosity and number density of each region were calculated. Statistical analyses were performed using Welch two sample t-test, Friedman one-way rank sum test and Nemenyi post-hoc test. The defect volume distribution type was determined based on Akaike information criterion (AIC). The core ceramic contained fewer defects (p<0.001) than the veneer layer. The size of smaller defects, which were 95% of the total, obeyed a logarithmic normal distribution. Region CF showed higher porosity (p<0.001) than the other regions. Defect number density of region CF was higher than region C (p<0.001) and region AW (p=0.029), but no difference was found between region CF and OF (p>0.05). Four of ten specimens contained the largest pores in region CF, while for the remaining six specimens the largest pore was in region OF. LDG core ceramic contained fewer defects than the veneer ceramic. LDG strength estimated from pore size was comparable to literature values. Large defects were more likely to appear at the core-veneer interface of occlusal fossa, while small defects also distributed in every region of the crowns but tended to aggregate in the central fossa region. Size distribution of small defects in veneer obeyed a logarithmic normal distribution. Copyright © 2017. Published by Elsevier Ltd.

  6. Jet and flash imprint defectivity: assessment and reduction for semiconductor applications

    NASA Astrophysics Data System (ADS)

    Malloy, Matt; Litt, Lloyd C.; Johnson, Steve; Resnick, Douglas J.; Lovell, David

    2011-04-01

    Defectivity has been historically identified as a leading technical roadblock to the implementation of nanoimprint lithography for semiconductor high volume manufacturing. The lack of confidence in nanoimprint's ability to meet defect requirements originates in part from the industry's past experiences with 1X lithography and the shortage in end-user generated defect data. SEMATECH has therefore initiated a defect assessment aimed at addressing these concerns. The goal is to determine whether nanoimprint, specifically Jet and Flash Imprint Lithography from Molecular Imprints, is capable of meeting semiconductor industry defect requirements. At this time, several cycles of learning have been completed in SEMATECH's defect assessment, with promising results. J-FIL process random defectivity of < 0.1 def/cm2 has been demonstrated using a 120nm half-pitch template, providing proof of concept that a low defect nanoimprint process is possible. Template defectivity has also improved significantly as shown by a pre-production grade template at 80nm pitch. Cycles of learning continue on feature sizes down to 22nm.

  7. Four-dimensional ultrasonography of the fetal heart using color Doppler spatiotemporal image correlation.

    PubMed

    Gonçalves, Luís F; Romero, Roberto; Espinoza, Jimmy; Lee, Wesley; Treadwell, Marjorie; Chintala, Kavitha; Brandl, Helmut; Chaiworapongsa, Tinnakorn

    2004-04-01

    To describe clinical and research applications of 4-dimensional imaging of the fetal heart using color Doppler spatiotemporal image correlation. Forty-four volume data sets were acquired by color Doppler spatiotemporal image correlation. Seven subjects were examined: 4 fetuses without abnormalities, 1 fetus with ventriculomegaly and a hypoplastic cerebellum but normal cardiac anatomy, and 2 fetuses with cardiac anomalies detected by fetal echocardiography (1 case of a ventricular septal defect associated with trisomy 21 and 1 case of a double-inlet right ventricle with a 46,XX karyotype). The median gestational age at the time of examination was 21 3/7 weeks (range, 19 5/7-34 0/7 weeks). Volume data sets were reviewed offline by multiplanar display and volume-rendering methods. Representative images and online video clips illustrating the diagnostic potential of this technology are presented. Color Doppler spatiotemporal image correlation allowed multiplanar visualization of ventricular septal defects, multiplanar display and volume rendering of tricuspid regurgitation, volume rendering of the outflow tracts by color and power Doppler ultrasonography (both in a normal case and in a case of a double-inlet right ventricle with a double-outlet right ventricle), and visualization of venous streams at the level of the foramen ovale. Color Doppler spatiotemporal image correlation has the potential to simplify visualization of the outflow tracts and improve the evaluation of the location and extent of ventricular septal defects. Other applications include 3-dimensional evaluation of regurgitation jets and venous streams at the level of the foramen ovale.

  8. Treatment of open tibial shaft fracture with soft tissue and bone defect caused by aircraft bomb--case report.

    PubMed

    Golubović, Zoran; Vidić, Goran; Trenkić, Srbobran; Vukasinović, Zoran; Lesić, Aleksandar; Stojiljković, Predrag; Stevanović, Goran; Golubović, Ivan; Visnjić, Aleksandar; Najman, Stevo

    2010-01-01

    Aircraft bombs can cause severe orthopaedic injuries. Tibia shaft fractures caused by aircraft bombs are mostly comminuted and followed by bone defects, which makes the healing process extremely difficult and prone to numerous complications. The goal of this paper is to present the method of treatment and the end results of treatment of a serious open tibial fracture with soft and bone tissue defects resulting from aircraft bomb shrapnel wounds. A 26-year-old patient presented with a tibial fracture as the result of a cluster bomb shrapnel wound. He was treated applying the method of external bone fixation done two days after wounding, as well as of early coverage of the lower leg soft tissue defects done on the tenth day after the external fixation of the fracture. The external fixator was removed after five months, whereas the treatment was continued by means of functional plaster cast for another two months. The final functional result was good. Radical wound debridement, external bone fixation of the fracture, and early reconstruction of any soft tissue and bone defects are the main elements of the treatment of serious fractures.

  9. Efficacy of combination therapy using anorganic bovine bone graft with resorbable GTR membrane vs. open flap debridement alone in the management of grade II furcation defects in mandibular molars – A comparative study

    PubMed Central

    Kannan, Anitha Logaranjani; Bose, Buvaneshwari Birla; Muthu, Jananni; Perumalsamy, Rajapriya; Pushparajan, Saravanan; Namasivayam, Ambalavanan

    2014-01-01

    Context: Invasion of the bifurcation and trifurcation of the multi-rooted teeth resulting in furcation involvement is one of the serious complications of periodontitis. Aim: The purpose of the study was to evaluate the efficacy of combination therapy using anorganic bovine bone graft and resorbable guided tissue regeneration (GTR) membrane versus open flap debridement alone in the management of Grade II furcation defects in mandibular molars. Materials and Methods: The study included a total number of 20 sites in 10 patients with bilateral mandibular furcation defects, out of which 10 sites were treated as test group and 10 as control group. The test group was treated with combination therapy and the control group with open flap debridement alone. The parameters were recorded on 0 day (baseline), 90th day, and 180th day, which included vertical probing depth and horizontal probing depth of the furcation defect, clinical attachment level, and defect fill. Statistical Analysis Used: Mean and standard deviation were calculated for different variables in each study group at different time points. Mean values were compared by using Wilcoxon signed ranks test, after adjusting the P values for multiple comparison by using Bonferroni correction method. Results: Both the test and control groups showed a definitive improvement in clinical parameters, which was statistically significant. On comparison, the vertical probing depth showed significant reduction in the test group with a mean reduction of 3.1 ± 0.7 mm, when compared to the control group which showed a mean reduction of 1.5 ± 0.5 mm. The horizontal probing depth of furcation defects was also significantly reduced in the test group with a mean reduction of 2.2 ± 0.6 mm, when compared to the control group in which the mean reduction was 0.9 ± 0.3 mm. There was also significant gain in attachment level in the test group which showed a mean gain of 3.2 ± 0.6 mm, when compared to the control group which showed a gain of 1.2 ± 0.6 mm. Radiographic defect fill was found to be more in the test group with a mean gain of 2.0 ± 0.1 mm, when compared to the control group which showed a defect fill of 0.2 ± 0.1 mm. Conclusions: The results of this study demonstrated that the combined use of anorganic bovine bone graft and resorbable GTR membrane is effective than open flap debridement alone in the treatment of mandibular grade II furcation defects. PMID:25452926

  10. 40 CFR 61.275 - Periodic report.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... internal floating roof, or there are holes, tears or other openings in the seal or seal fabric; or (ii... has defects, the primary seal has holes, tears, or other openings in the seal or the seal fabric, or the secondary seal (if one has been installed) has holes, tears, or other openings in the seal or the...

  11. Bypassing An Open-Circuit Power Cell

    NASA Technical Reports Server (NTRS)

    Wannemacher, Harry E.

    1994-01-01

    Collection of bypass circuits enables battery consisting series string of cells to continue to function when one of its cells fails in open-circuit (high-resistance) condition. Basic idea simply to shunt current around defective cell to prevent open circuit from turning off battery altogether. Bypass circuits dissipate little power and are nearly immune to false activation.

  12. Relationship between progression of visual field defect and intraocular pressure in primary open-angle glaucoma.

    PubMed

    Naito, Tomoko; Yoshikawa, Keiji; Mizoue, Shiro; Nanno, Mami; Kimura, Tairo; Suzumura, Hirotaka; Shiraga, Fumio

    2015-01-01

    To analyze the relationship between intraocular pressure (IOP) and the progression of visual field defects in Japanese primary open-angle glaucoma (POAG) and normal-tension glaucoma (NTG) patients. The subjects of the study were patients undergoing treatment for POAG or NTG who had performed visual field tests at least ten times with a Humphrey field analyzer (Swedish interactive thresholding algorithm standard, C30-2 program). The progression of visual field defects was defined by a significantly negative value of the mean deviation slope at the final visual field test during the follow-up period. The relationships between the progression of visual field defects and IOP, as well as other clinical factors, were retrospectively analyzed. A total of 156 eyes of 156 patients were included in the analysis. Significant progression of visual field defects was observed in 70 eyes of 70 patients (44.9%), while no significant progression was evident in 86 eyes of 86 patients (55.1%). The eyes with visual field defect progression had significantly lower baseline IOP (P<0.05), as well as significantly lower IOP reduction rate (P<0.01). The standard deviation of IOP values during follow-up was significantly greater in the eyes with visual field defect progression than in eyes without (P<0.05). Reducing IOP is thought to be useful for Japanese POAG or NTG patients to suppress the progression of visual field defects. In NTG, IOP management should take into account not only achieving the target IOP, but also minimizing the fluctuation of IOP during follow-up period.

  13. USE OF BIOCERAMICS IN FILLING BONE DEFECTS

    PubMed Central

    Garrido, Carlos Antõnio; Sampaio, Tania Clarete Fonseca Vieira Sales

    2015-01-01

    Objective: To present the results from using biological ceramics for filling bone defects resulting from post-traumatic or orthopedic injuries. Methods: Thirty-six patients with bone defects caused by trauma or orthopedic injury were evaluated. Nineteen patients were male (52.8%) and 17 were female (47.2%). Their ages ranged from 19 to 84 years, with a mean of 45.7 years and median of 37 years. Only patients with defects that required at least five grams of biological ceramic were included. Eighteen cases were classified as orthopedic: bone defects were observed in 11 cases of total hip arthroplasty; one case of primary total hip arthroplasty, due to coxarthrosis; five cases of femoral or tibial open wedge osteotomy; and one case of tarsal arthrodesis. There were 18 cases of trauma-related defects; uninfected pseudarthrosis, eight cases; recent fractures of the tibial plateau with compression of the spongy bone, three cases; and exposed fractures treated with external fixators, seven cases. The surgical technique consisted of curetting and debriding the injury until bone suitable for grafting was found. Biological ceramic was then used to fill the defect and some kind of fixation was applied. Results: Among the 36 patients evaluated, it was seen that 35 (97.2%) presented integration of the biological ceramic, while one case of open fracture treated with external fixation had poor integration of the biological ceramic. Conclusion: Treatment of bone defects of orthopedic or post-traumatic etiology using a phosphocalcium ceramic composed of hydroxyapatite was shown to be a practical, effective and safe method. PMID:27022576

  14. Pharmacological Correction of Trafficking Defects in ATP-sensitive Potassium Channels Caused by Sulfonylurea Receptor 1 Mutations*

    PubMed Central

    Martin, Gregory M.; Rex, Emily A.; Devaraneni, Prasanna; Denton, Jerod S.; Boodhansingh, Kara E.; DeLeon, Diva D.; Stanley, Charles A.; Shyng, Show-Ling

    2016-01-01

    ATP-sensitive potassium (KATP) channels play a key role in mediating glucose-stimulated insulin secretion by coupling metabolic signals to β-cell membrane potential. Loss of KATP channel function due to mutations in ABCC8 or KCNJ11, genes encoding the sulfonylurea receptor 1 (SUR1) or the inwardly rectifying potassium channel Kir6.2, respectively, results in congenital hyperinsulinism. Many SUR1 mutations prevent trafficking of channel proteins from the endoplasmic reticulum to the cell surface. Channel inhibitors, including sulfonylureas and carbamazepine, have been shown to correct channel trafficking defects. In the present study, we identified 13 novel SUR1 mutations that cause channel trafficking defects, the majority of which are amenable to pharmacological rescue by glibenclamide and carbamazepine. By contrast, none of the mutant channels were rescued by KATP channel openers. Cross-linking experiments showed that KATP channel inhibitors promoted interactions between the N terminus of Kir6.2 and SUR1, whereas channel openers did not, suggesting the inhibitors enhance intersubunit interactions to overcome channel biogenesis and trafficking defects. Functional studies of rescued mutant channels indicate that most mutants rescued to the cell surface exhibited WT-like sensitivity to ATP, MgADP, and diazoxide. In intact cells, recovery of channel function upon trafficking rescue by reversible sulfonylureas or carbamazepine was facilitated by the KATP channel opener diazoxide. Our study expands the list of KATP channel trafficking mutations whose function can be recovered by pharmacological ligands and provides further insight into the structural mechanism by which channel inhibitors correct channel biogenesis and trafficking defects. PMID:27573238

  15. Redo-urethroplasty in pelvic fracture urethral distraction defect: an audit.

    PubMed

    Bhagat, Suresh K; Gopalakrishnan, Ganesh; Kumar, Santosh; Devasia, Antony; Kekre, Nitin S

    2011-02-01

    To predict the outcome of redo-urethroplasty after failed single or multiple open urethral procedures for pelvic fracture urethral distraction defects. From January 1997 to December 2006, 43 patients underwent redo-urethroplasty for pelvic fracture urethral distraction defect. Forty-one were referred from other centers. All had undergone open surgery along with an endoscopic procedure (one or more procedures in each patient) which included endoscopic internal urethrotomy, urethral stenting or urethral dilations. There were 43 men with mean age of 29 (range 11-52). Eleven had associated injuries: intraperitoneal bladder rupture (3), bladder neck (2), rectum (3), anal sphincter (2), combined bladder, rectum and anal sphincter (1). Trocar suprapubic cystostomy was performed in 22, rail-road procedures in 10 and open suprapubic cystostomy in 11 along with the management of associated injuries as immediate treatment. Of 43 patients, 28 had progressive perineal, and 12 had transpubic repair. Three patients had total bulbar necrosis, and they underwent prepuceal tube reconstruction (1) and staged substitution with BMG and standard scrotal inlay (2). Analysis of various factors like number of attempts at previous surgery and stricture length did not affect the outcome. A successful result was achieved in 36 (83.72%), improved and stable in five and failure in two. The overall result of redo-urethroplasty for pelvic fracture urethral distraction defect continues to be gratifying. Failures happen usually within the first 3 months. Substitution urethroplasty can be reserved for those who have long distraction defect. Long-term follow-up is essential using stringent criteria to measure success.

  16. Complex Cardiac Surgery on Patients with a Body Weight of Less Than 5 kg without Donor Blood Transfusion

    PubMed Central

    Boettcher, Wolfgang; Dehmel, Frank; Redlin, Mathias; Miera, Oliver; Musci, Michele; Cho, Mi-Young; Photiadis, Joachim

    2017-01-01

    Abstract: Performing safe cardiac surgery in neonates or infants whose parents are Jehovah's Witnesses is only possible in a coordinated team approach. An unconditional prerequisite is a cardiopulmonary bypass (CPB) circuit with a very low priming volume to minimize hemodilution. In the past decade, we have developed a functional blood-sparing approach at our institution. The extracorporeal circuit was miniaturized. This had to be recently adapted, faced with a challenge associated with the switch to high-volume crystalloid cardioplegia. A filtration circuit was added. Here, we report an open heart surgery on three consecutive children of Jehovah's Witness parents with a body weight of 2.7, 4.5, and 4.8 kg, respectively. Procedures consisted of one arterial switch operation and two repairs of complete atrioventricular septal defects. Our static priming volume of less than 90 mL resulted in a nadir hematocrit during CPB of 27.7% (Hb 8.9 g/dL) in a patient which happened to have the lowest body weight of 2.7 kg. The two other patients had their lowest hematocrit at 31.4% (Hb 10.2 g/dL). The three children could be treated without any kind of transfusion of blood which had left the circulation or its extensions, in accordance with the parents' wishes, and enjoy favorable outcomes without transfusion of blood products during their entire hospital stay. PMID:28638157

  17. Treatment of open tibial fracture with bone defect caused by high velocity missiles: a case report.

    PubMed

    Golubović, Zoran; Vukajinović, Zoran; Stojiljković, Predrag; Golubović, Ivan; Visnjić, Aleksandar; Radovanović, Zoran; Najman, Stevo

    2013-01-01

    Tibia fracture caused by high velocity missiles is mostly comminuted and followed by bone defect which makes their healing process extremely difficult and prone to numerous complications. A 34-year-old male was wounded at close range by a semi-automatic gun missile. He was wounded in the distal area of the left tibia and suffered a massive defect of the bone and soft tissue. After the primary treatment of the wound, the fracture was stabilized with an external fixator type Mitkovic, with convergent orientation of the pins. The wound in the medial region of the tibia was closed with the secondary stitch, whereas the wound in the lateral area was closed with the skin transplant after Thiersch. Due to massive bone defect in the area of the rifle-missile wound six months after injury, a medical team placed a reconstructive external skeletal fixator type Mitkovic and performed corticotomy in the proximal metaphyseal area of the tibia. By the method of bone transport (distractive osteogenesis), the bone defect of the tibia was replaced. After the fracture healing seven months from the secondary surgery, the fixator was removed and the patient was referred to physical therapy. Surgical treatment of wounds, external fixation, performing necessary debridement, adequate antibiotic treatment and soft and bone tissue reconstruction are essential in achieving good results in patients with the open tibial fracture with bone defect caused by high velocity missiles. Reconstruction of bone defect can be successfully treated by reconstructive external fixator Mitkovic.

  18. Studies of silicon PN junction solar cells

    NASA Technical Reports Server (NTRS)

    Lindholm, F. A.

    1975-01-01

    Silicon pn junction solar cells made with low-resistivity substrates show poorer performance than traditional theory predicts. The purpose of this research was to identify and characterize the physical mechanisms responsible for the discrepancy. Attention was concentrated on the open circuit voltage in shallow junction cells of 0.1 ohm-cm substrate resistivity. A number of possible mechanisms that can occur in silicon devices were considered. Two mechanisms which are likely to be of main importance in explaining the observed low values of open-circuit voltage were found: (1) recombination losses associated with defects introduced during junction formation, and (2) inhomogeneity of defects and impurities across the area of the cell. To explore these theoretical anticipations, various diode test structures were designed and fabricated and measurement configurations for characterizing the defect properties and the areal inhomogeneity were constructed.

  19. Defect nonunion of a metatarsal bone fracture in a cow: successful management with bone plating and autogenous cancellous bone graft.

    PubMed

    Raghunath, M; Singh, N; Singh, T; Gopinathan, A; Mohindroo, J; Atri, K

    2013-01-01

    A two-and-half-year-old cow was presented with a defect nonunion of the right metatarsal III/IV bone following a severely comminuted open fracture two months previously. The animal underwent open fixation using a 4.5 mm, broad, 10-hole, dynamic compression plate and autogenous cancellous bone graft collected from the contralateral iliac shaft. The animal started partial weight bearing after the third postoperative day and resumed complete weight bearing after the 10th day. Fracture healing was complete and the implants were removed after the 120th postoperative day. Stable fixation by means of a bone plate in conjunction with a cancellous bone graft facilitated complete healing and restoration of the bone column of the defect and the metatarsal fracture. The animal made a complete recovery.

  20. Free energy landscape and localization of nanoparticles at block copolymer model defects.

    PubMed

    Kim, Yongjoo; Chen, Hsieh; Alexander-Katz, Alfredo

    2014-05-14

    Nanoparticle localization in block copolymer model defects is studied using self-consistent field theory simulations. In particular we study the nanoparticle free energy landscape for three different model defects: X, T, Y shape defects. Our results indicate that nanoparticles can be strongly bound to certain locations in these defects. The symmetry of the defects affects in a non-trivial fashion the "stiffness of the trap", with the X shape defect displaying the deepest energy well. The T and Y defects exhibit orientations along which the potential energy well is rather shallow. Furthermore, we find that the free energy well is tunable by the size of the nanoparticles. Our results help to explain recent experimental observations in block copolymer templated assembly of nanoparticles. Furthermore, they may open new avenues to assemble arbitrary heterogeneous patterns with precise nanoparticle positions by carefully controlling the morphology of a block copolymer system by using directed self-assembly techniques.

  1. ["Open" surgery of mitral heart diseases complicated by pulmonary hypertension].

    PubMed

    Abdumazhidov, Kh A; Guliamov, D S; Amanov, A A

    2000-01-01

    Under analysis were the results of 386 operations on the "open" heart made for mitral diseases complicated by pulmonary hypertension of different degrees. Prosthetics of the mitral valve was performed in 251 patients, in 135 patients the so-called "organ-saving" correction of the defect was fulfilled. The decision on the method of the defect correction depends on the anatomical particularities, morphological alterations of the valvular apparatus. The main place among the causes of postoperative lethality (9-11%) is occupied by cardiac insufficiency and renohepatic failure which are noted mainly in patients of the IVth functional class.

  2. The relationship between grain boundary structure, defect mobility, and grain boundary sink efficiency

    PubMed Central

    Uberuaga, Blas Pedro; Vernon, Louis J.; Martinez, Enrique; Voter, Arthur F.

    2015-01-01

    Nanocrystalline materials have received great attention due to their potential for improved functionality and have been proposed for extreme environments where the interfaces are expected to promote radiation tolerance. However, the precise role of the interfaces in modifying defect behavior is unclear. Using long-time simulations methods, we determine the mobility of defects and defect clusters at grain boundaries in Cu. We find that mobilities vary significantly with boundary structure and cluster size, with larger clusters exhibiting reduced mobility, and that interface sink efficiency depends on the kinetics of defects within the interface via the in-boundary annihilation rate of defects. Thus, sink efficiency is a strong function of defect mobility, which depends on boundary structure, a property that evolves with time. Further, defect mobility at boundaries can be slower than in the bulk, which has general implications for the properties of polycrystalline materials. Finally, we correlate defect energetics with the volumes of atomic sites at the boundary. PMID:25766999

  3. The relationship between grain boundary structure, defect mobility, and grain boundary sink efficiency

    DOE PAGES

    Uberuaga, Blas Pedro; Vernon, Louis J.; Martinez, Enrique; ...

    2015-03-13

    Nanocrystalline materials have received great attention due to their potential for improved functionality and have been proposed for extreme environments where the interfaces are expected to promote radiation tolerance. However, the precise role of the interfaces in modifying defect behavior is unclear. Using long-time simulations methods, we determine the mobility of defects and defect clusters at grain boundaries in Cu. We find that mobilities vary significantly with boundary structure and cluster size, with larger clusters exhibiting reduced mobility, and that interface sink efficiency depends on the kinetics of defects within the interface via the in-boundary annihilation rate of defects. Thus,more » sink efficiency is a strong function of defect mobility, which depends on boundary structure, a property that evolves with time. Further, defect mobility at boundaries can be slower than in the bulk, which has general implications for the properties of polycrystalline materials. Finally, we correlate defect energetics with the volumes of atomic sites at the boundary.« less

  4. Annealing properties of open volumes in HfSiOx and HfAlOx gate dielectrics studied using monoenergetic positron beams

    NASA Astrophysics Data System (ADS)

    Uedono, A.; Ikeuchi, K.; Yamabe, K.; Ohdaira, T.; Muramatsu, M.; Suzuki, R.; Hamid, A. S.; Chikyow, T.; Torii, K.; Yamada, K.

    2005-07-01

    Thin Hf0.6Si0.4Ox and Hf0.3Al0.7Ox films fabricated by metal-organic chemical-vapor deposition and atomic-layer-deposition techniques were characterized using monoenergetic positron beams. Measurements of the Doppler broadening spectra of annihilation radiation and the lifetime spectra of positions indicated that positrons annihilated from the trapped state by open volumes that exist intrinsically in amorphous structures of the films. For HfSiOx, the mean size of the open volumes and their size distribution decreased with increasing postdeposition annealing (PDA) temperature. For HfAlOx, although the overall behavior of the open volumes in response to annealing was similar to that for HfSiOx, PDA caused a separation of the mean size of the open volumes. When this separation occurred, the value of the line-shape parameter S increased, suggesting an oxygen deficiency in the amorphous matrix. This fragmentation of the amorphous matrix can be suppressed by decreasing the annealing time.

  5. Lightweight Open-Cell Scaffolds from Sea Urchin Spines with Superior Material Properties for Bone Defect Repair.

    PubMed

    Cao, Lei; Li, Xiaokang; Zhou, Xiaoshu; Li, Yong; Vecchio, Kenneth S; Yang, Lina; Cui, Wei; Yang, Rui; Zhu, Yue; Guo, Zheng; Zhang, Xing

    2017-03-22

    Sea urchin spines (Heterocentrotus mammillatus), with a hierarchical open-cell structure similar to that of human trabecular bone and superior mechanical property (compressive strength ∼43.4 MPa) suitable for machining to shape, were explored for potential applications of bone defect repair. Finite element analyses reveal that the compressive stress concentrates along the dense growth rings and dissipates through strut structures of the stereoms, indicating that the exquisite mesostructures play an important role in high strength-to-weight ratios. The fracture strength of magnesium-substituted tricalcium phosphate (β-TCMP) scaffolds produced by hydrothermal conversion of urchin spines is about 9.3 MPa, comparable to that of human trabecular bone. New bone forms along outer surfaces of β-TCMP scaffolds after implantation in rabbit femoral defects for one month and grows into the majority of the inner open-cell spaces postoperation in three months, showing tight interface between the scaffold and regenerative bone tissue. Fusion of beagle lumbar facet joints using a Ti-6Al-4V cage and β-TCMP scaffold can be completed within seven months with obvious biodegradation of the β-TCMP scaffold, which is nearly completely degraded and replaced by newly formed bone ten months after implantation. Thus, sea urchin spines suitable for machining to shape have advantages for production of biodegradable artificial grafts for bone defect repair.

  6. Real-Time Magnetic Resonance-Guided Stereotactic Laser Amygdalohippocampotomy for Mesial Temporal Lobe Epilepsy

    PubMed Central

    Willie, Jon T.; Laxpati, Nealen G.; Drane, Daniel L.; Gowda, Ashok; Appin, Christina; Hao, Chunhai; Brat, Daniel J.; Helmers, Sandra L.; Saindane, Amit; Nour, Sherif G.; Gross, Robert E.

    2014-01-01

    Background Open surgery effectively treats mesial temporal lobe epilepsy (MTLE), but carries risks of neurocognitive deficits, which may be reduced with minimally invasive alternatives. Objective To describe technical and clinical outcomes of stereotactic laser amygdalohippocampotomy (SLAH) with real-time magnetic resonance thermal imaging (MRTI) guidance. Methods Under general anesthesia and utilizing standard stereotactic methods, 13 adult patients with intractable MTLE (with and without mesial temporal sclerosis, MTS) prospectively underwent insertion of a saline-cooled fiber-optic laser applicator into amygdalohippocampal structures from an occipital trajectory. Computer-controlled laser ablation was performed during continuous MRTI followed by confirmatory contrast-enhanced anatomic imaging and volumetric reconstruction. Clinical outcomes were determined from seizure diaries. Results A mean 60% volume of the amygdalohippocampal complex was ablated in 13 patients (9 with MTS) undergoing 15 procedures. Median hospitalization was one day. With follow-up ranging from 5-26 (median 14) months, 77% (10/13) of patients achieved meaningful seizure reduction, of which 54% (7/13) were free of disabling seizures. Of patients with preoperative MTS, 67% (6/9) achieved seizure freedom. All recurrences were observed by<6 months. Variances in ablation volume and length did not account for individual clinical outcomes. Whereas no complications of laser therapy itself were observed, one significant complication, a visual field defect, resulted from deviated insertion of a stereotactic aligning rod, which was corrected prior to ablation. Conclusion Real-time MR-guided SLAH is a technically novel, safe, and effective alternative to open surgery. Further evaluation with larger cohorts over time is warranted. PMID:24618797

  7. Nanometer-scale surface potential and resistance mapping of wide-bandgap Cu(In,Ga)Se2 thin films

    NASA Astrophysics Data System (ADS)

    Jiang, C.-S.; Contreras, M. A.; Mansfield, L. M.; Moutinho, H. R.; Egaas, B.; Ramanathan, K.; Al-Jassim, M. M.

    2015-01-01

    We report microscopic characterization studies of wide-bandgap Cu(In,Ga)Se2 photovoltaic thin films using the nano-electrical probes of scanning Kelvin probe force microscopy and scanning spreading resistance microscopy. With increasing bandgap, the potential imaging shows significant increases in both the large potential features due to extended defects or defect aggregations and the potential fluctuation due to unresolvable point defects with single or a few charges. The resistance imaging shows increases in both overall resistance and resistance nonuniformity due to defects in the subsurface region. These defects are expected to affect open-circuit voltage after the surfaces are turned to junction upon device completion.

  8. Conduit purging device and method

    NASA Technical Reports Server (NTRS)

    Wilks, Michael T. (Inventor)

    2011-01-01

    A device for purging gas comprises a conduit assembly defining an interior volume. The conduit assembly comprises a first conduit portion having an open first end and an open second end and a second conduit portion having an open first end and a closed second end. The open second end of the first conduit portion is disposed proximate to the open first end of the second conduit portion to define a weld region. The device further comprises a supply element supplying a gas to the interior volume at a substantially constant rate and a vent element venting the gas from the interior volume at a rate that maintains the gas in the interior volume within a pressure range suitable to hold a weld bead in the weld region in equilibrium during formation of a weld to join the first conduit portion and the second conduit portion.

  9. Observation of zone folding induced acoustic topological insulators and the role of spin-mixing defects

    NASA Astrophysics Data System (ADS)

    Deng, Yuanchen; Ge, Hao; Tian, Yuan; Lu, Minghui; Jing, Yun

    2017-11-01

    This article reports on the experimental realization of a flow-free, pseudospin-based acoustic topological insulator designed using the strategy of zone folding. Robust sound one-way propagation is demonstrated with the presence of non-spin-mixing defects. On the other hand, it is shown that spin-mixing defects, which break the geometric symmetry and therefore the pseudo-time-reversal symmetry, can open up nontrivial band gaps within the edge state frequency band, and their width can be tailored by the extent of the defect. This provides a possible route for realizing tunable acoustic topological insulators.

  10. Effective bichromatic potential for ultra-high Q-factor photonic crystal slab cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alpeggiani, Filippo, E-mail: filippo.alpeggiani01@ateneopv.it; Andreani, Lucio Claudio; Gerace, Dario

    2015-12-28

    We introduce a confinement mechanism in photonic crystal slab cavities, which relies on the superposition of two incommensurate one-dimensional lattices in a line-defect waveguide. It is shown that the resulting photonic profile realizes an effective quasi-periodic bichromatic potential for the electromagnetic field confinement yielding extremely high quality (Q) factor nanocavities, while simultaneously keeping the mode volume close to the diffraction limit. We apply these concepts to pillar- and hole-based photonic crystal slab cavities, respectively, and a Q-factor improvement by over an order of magnitude is shown over existing designs, especially in pillar-based structures. Thanks to the generality and easy adaptationmore » of such confinement mechanism to a broad class of cavity designs and photonic lattices, this work opens interesting routes for applications where enhanced light–matter interaction in photonic crystal structures is required.« less

  11. Nanometer-scale mapping of irreversible electrochemical nucleation processes on solid Li-ion electrolytes

    NASA Astrophysics Data System (ADS)

    Kumar, Amit; Arruda, Thomas M.; Tselev, Alexander; Ivanov, Ilia N.; Lawton, Jamie S.; Zawodzinski, Thomas A.; Butyaev, Oleg; Zayats, Sergey; Jesse, Stephen; Kalinin, Sergei V.

    2013-04-01

    Electrochemical processes associated with changes in structure, connectivity or composition typically proceed via new phase nucleation with subsequent growth of nuclei. Understanding and controlling reactions requires the elucidation and control of nucleation mechanisms. However, factors controlling nucleation kinetics, including the interplay between local mechanical conditions, microstructure and local ionic profile remain inaccessible. Furthermore, the tendency of current probing techniques to interfere with the original microstructure prevents a systematic evaluation of the correlation between the microstructure and local electrochemical reactivity. In this work, the spatial variability of irreversible nucleation processes of Li on a Li-ion conductive glass-ceramics surface is studied with ~30 nm resolution. An increased nucleation rate at the boundaries between the crystalline AlPO4 phase and amorphous matrix is observed and attributed to Li segregation. This study opens a pathway for probing mechanisms at the level of single structural defects and elucidation of electrochemical activities in nanoscale volumes.

  12. A coupled approach for the three-dimensional simulation of pipe leakage in variably saturated soil

    NASA Astrophysics Data System (ADS)

    Peche, Aaron; Graf, Thomas; Fuchs, Lothar; Neuweiler, Insa

    2017-12-01

    In urban water pipe networks, pipe leakage may lead to subsurface contamination or to reduced waste water treatment efficiency. The quantification of pipe leakage is challenging due to inaccessibility and unknown hydraulic properties of the soil. A novel physically-based model for three-dimensional numerical simulation of pipe leakage in variably saturated soil is presented. We describe the newly implemented coupling between the pipe flow simulator HYSTEM-EXTRAN and the groundwater flow simulator OpenGeoSys and its validation. We further describe a novel upscaling of leakage using transfer functions derived from numerical simulations. This upscaling enables the simulation of numerous pipe defects with the benefit of reduced computation times. Finally, we investigate the response of leakage to different time-dependent pipe flow events and conclude that larger pipe flow volume and duration lead to larger leakage while the peak position in time has a small effect on leakage.

  13. Tunable cavity coupling of the zero phonon line of a nitrogen-vacancy defect in diamond

    NASA Astrophysics Data System (ADS)

    Johnson, S.; Dolan, P. R.; Grange, T.; Trichet, A. A. P.; Hornecker, G.; Chen, Y. C.; Weng, L.; Hughes, G. M.; Watt, A. A. R.; Auffèves, A.; Smith, J. M.

    2015-12-01

    We demonstrate the tunable enhancement of the zero phonon line of a single nitrogen-vacancy colour centre in diamond at cryogenic temperature. An open cavity fabricated using focused ion beam milling provides mode volumes as small as 1.24 μm3 (4.7 {λ }3) and quality factor Q≃ 3000. In situ tuning of the cavity resonance is achieved with piezoelectric actuators. At optimal coupling to a TEM00 cavity mode, the signal from individual zero phonon line transitions is enhanced by a factor of 6.25 and the overall emission rate of the NV- centre is increased by 40% compared with that measured from the same centre in the absence of cavity field confinement. This result represents a step forward in the realisation of efficient spin-photon interfaces and scalable quantum computing using optically addressable solid state spin qubits.

  14. Nanometer-scale mapping of irreversible electrochemical nucleation processes on solid Li-ion electrolytes.

    PubMed

    Kumar, Amit; Arruda, Thomas M; Tselev, Alexander; Ivanov, Ilia N; Lawton, Jamie S; Zawodzinski, Thomas A; Butyaev, Oleg; Zayats, Sergey; Jesse, Stephen; Kalinin, Sergei V

    2013-01-01

    Electrochemical processes associated with changes in structure, connectivity or composition typically proceed via new phase nucleation with subsequent growth of nuclei. Understanding and controlling reactions requires the elucidation and control of nucleation mechanisms. However, factors controlling nucleation kinetics, including the interplay between local mechanical conditions, microstructure and local ionic profile remain inaccessible. Furthermore, the tendency of current probing techniques to interfere with the original microstructure prevents a systematic evaluation of the correlation between the microstructure and local electrochemical reactivity. In this work, the spatial variability of irreversible nucleation processes of Li on a Li-ion conductive glass-ceramics surface is studied with ~30 nm resolution. An increased nucleation rate at the boundaries between the crystalline AlPO4 phase and amorphous matrix is observed and attributed to Li segregation. This study opens a pathway for probing mechanisms at the level of single structural defects and elucidation of electrochemical activities in nanoscale volumes.

  15. Nanometer-scale mapping of irreversible electrochemical nucleation processes on solid Li-ion electrolytes

    PubMed Central

    Kumar, Amit; Arruda, Thomas M.; Tselev, Alexander; Ivanov, Ilia N.; Lawton, Jamie S.; Zawodzinski, Thomas A.; Butyaev, Oleg; Zayats, Sergey; Jesse, Stephen; Kalinin, Sergei V.

    2013-01-01

    Electrochemical processes associated with changes in structure, connectivity or composition typically proceed via new phase nucleation with subsequent growth of nuclei. Understanding and controlling reactions requires the elucidation and control of nucleation mechanisms. However, factors controlling nucleation kinetics, including the interplay between local mechanical conditions, microstructure and local ionic profile remain inaccessible. Furthermore, the tendency of current probing techniques to interfere with the original microstructure prevents a systematic evaluation of the correlation between the microstructure and local electrochemical reactivity. In this work, the spatial variability of irreversible nucleation processes of Li on a Li-ion conductive glass-ceramics surface is studied with ~30 nm resolution. An increased nucleation rate at the boundaries between the crystalline AlPO4 phase and amorphous matrix is observed and attributed to Li segregation. This study opens a pathway for probing mechanisms at the level of single structural defects and elucidation of electrochemical activities in nanoscale volumes. PMID:23563856

  16. Chin Symphysis Bone, Allograft, and Platelet-Rich Fibrin: Is the Combination Effective in Repair of Alveolar Cleft?

    PubMed

    Movahedian Attar, Bijan; Naghdi, Navid; Etemadi Sh, Milad; Mehdizadeh, Mojdeh

    2017-05-01

    Secondary grafting of alveolar defects with iliac crest bone is a common treatment method in cleft patients. The aim of this study was to evaluate the effectiveness of the combination of symphysis bone, allograft, and platelet-rich fibrin in regeneration of alveolar defects compared with iliac bone graft. In this randomized clinical trial, patients with unilateral alveolar defects were divided randomly into two categories. Group A comprised patients in whom the combination of chin symphysis bone plus allogeneic bone material plus leukocyte- and platelet-rich fibrin was considered for treatment. Group B comprised patients in whom iliac bone graft was considered. Cone beam computed tomography before treatment and 1 year postoperatively was used for measurement of bone formation (bone volume in cubic centimeters). The data were analyzed by paired t and χ 2 tests via SPSS software (version 23; IBM, Armonk, NY). P < .05 was considered significant. Each group included 10 patients (with 6 male patients in group A and 5 male patients in group B). The mean age of patients in groups A and B was 9.5 ± 1.5 years and 9.9 ± 1.9 years, respectively. The mean volume of alveolar defects was 0.89 ± 0.29 cm 3 in group A and 0.95 ± 0.27 cm 3 in group B. The percentage of bone regeneration in groups A and B was 69.5% and 73.8%, respectively. It seems that chin symphysis bone plus allogeneic bone material plus platelet-rich fibrin is a proper combination for bone regeneration in alveolar defects with a small to moderate volume range. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  17. High doses of bone morphogenetic protein 2 induce structurally abnormal bone and inflammation in vivo.

    PubMed

    Zara, Janette N; Siu, Ronald K; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M; Ting, Kang; Soo, Chia

    2011-05-01

    The major Food and Drug Association-approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL.

  18. High Doses of Bone Morphogenetic Protein 2 Induce Structurally Abnormal Bone and Inflammation In Vivo

    PubMed Central

    Zara, Janette N.; Siu, Ronald K.; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M.; Ting, Kang

    2011-01-01

    The major Food and Drug Association–approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL. PMID:21247344

  19. 3D imaging of intrinsic crystalline defects in zinc oxide by spectrally resolved two-photon fluorescence microscopy

    NASA Astrophysics Data System (ADS)

    Al-Tabich, A.; Inami, W.; Kawata, Y.; Jablonski, R.; Worasawat, S.; Mimura, H.

    2017-05-01

    We present a method for three-dimensional intrinsic defect imaging in zinc oxide (ZnO) by spectrally resolved two-photon fluorescence microscopy, based on the previously presented method of observing a photoluminescence distribution in wide-gap semiconductor crystals [Noor et al., Appl. Phys. Lett. 92(16), 161106 (2008)]. A tightly focused light beam radiated by a titanium-sapphire laser is used to obtain a two-photon excitation of selected area of the ZnO sample. Photoluminescence intensity of a specific spectral range is then selected by optical band pass filters and measured by a photomultiplier tube. Reconstruction of the specimen image is done by scanning the volume of interest by a piezoelectric positioning stage and measuring the spectrally resolved photoluminescence intensity at each point. The method has been proved to be effective at locating intrinsic defects of the ZnO crystalline structure in the volume of the crystal. The method was compared with other defect imaging and 3D imaging techniques like scanning tunneling microscopy and confocal microscopy. In both cases, our method shows superior penetration abilities and, as the only method, allows location of the defects of the chosen type in 3D. In this paper, we present the results of oxygen vacancies and zinc antisites imaging in ZnO nanorods.

  20. In-line inspection of unpiggable buried live gas pipes using circumferential EMAT guided waves

    NASA Astrophysics Data System (ADS)

    Ren, Baiyang; Xin, Junjun

    2018-04-01

    Unpiggable buried gas pipes need to be inspected to ensure their structural integrity and safe operation. The CIRRIS XITM robot, developed and operated by ULC Robotics, conducts in-line nondestructive inspection of live gas pipes. With the no-blow launching system, the inspection operation has reduced disruption to the public and by eliminating the need to dig trenches, has minimized the site footprint. This provides a highly time and cost effective solution for gas pipe maintenance. However, the current sensor on the robot performs a point-by-point measurement of the pipe wall thickness which cannot cover the whole volume of the pipe in a reasonable timeframe. The study of ultrasonic guided wave technique is discussed to improve the volume coverage as well as the scanning speed. Circumferential guided wave is employed to perform axial scanning. Mode selection is discussed in terms of sensitivity to different defects and defect characterization capability. To assist with the mode selection, finite element analysis is performed to evaluate the wave-defect interaction and to identify potential defect features. Pulse-echo and through-transmission mode are evaluated and compared for their pros and cons in axial scanning. Experiments are also conducted to verify the mode selection and detect and characterize artificial defects introduced into pipe samples.

  1. A Computational Framework for Automation of Point Defect Calculations

    NASA Astrophysics Data System (ADS)

    Goyal, Anuj; Gorai, Prashun; Peng, Haowei; Lany, Stephan; Stevanovic, Vladan; National Renewable Energy Laboratory, Golden, Colorado 80401 Collaboration

    A complete and rigorously validated open-source Python framework to automate point defect calculations using density functional theory has been developed. The framework provides an effective and efficient method for defect structure generation, and creation of simple yet customizable workflows to analyze defect calculations. The package provides the capability to compute widely accepted correction schemes to overcome finite-size effects, including (1) potential alignment, (2) image-charge correction, and (3) band filling correction to shallow defects. Using Si, ZnO and In2O3as test examples, we demonstrate the package capabilities and validate the methodology. We believe that a robust automated tool like this will enable the materials by design community to assess the impact of point defects on materials performance. National Renewable Energy Laboratory, Golden, Colorado 80401.

  2. Regional Microstructural and Volumetric Magnetic Resonance Imaging (MRI) Abnormalities in the Corpus Callosum of Neonates With Congenital Heart Defect Undergoing Cardiac Surgery.

    PubMed

    Hagmann, Cornelia; Singer, Jitka; Latal, Beatrice; Knirsch, Walter; Makki, Malek

    2016-03-01

    The purpose of the study is to investigate the structural development of the corpus callosum in term neonates with congenital heart defect before and after surgery using diffusion tensor imaging and 3-dimensional T1-weighted magnetic resonance imaging (MRI). We compared parallel and radial diffusions, apparent diffusion coefficient (ADC), fractional anisotropy, and volume of 5 substructures of the corpus callosum: genu, rostral body, body, isthmus, and splenium. Compared to healthy controls, we found a significantly lower volume of the splenium and total corpus callosum and a higher radial diffusion and lower fractional anisotropy in the splenium of patients presurgery; a lower volume in all substructures in the postsurgery group; higher radial diffusion in the rostral body, body, and splenium; and a higher apparent diffusion coefficient in the splenium of postsurgery patients. Similar fractional anisotropy changes in congenital heart defect patients were reported in preterm infants. Our findings in apparent diffusion coefficient in the splenium of these patients (pre and postsurgery) are comparable to findings in preterm neonates with psychomotor delay. Delayed maturation of the isthmus was also reported in preterm infants. © The Author(s) 2015.

  3. Percutaneous management of coronary sinus atrial septal defect: two cases representing the spectrum for device closure and a review of the literature.

    PubMed

    Sandeep, Nefthi; Slack, Michael C

    2014-10-01

    Coronary sinus atrial septal defects are the rarest defects of the atrial septum comprising <1% of the five different types of atrial septal defects. Despite the widespread adoption of percutaneous device closure of secundum atrial septal defects, the published experience with percutaneous device closure of coronary sinus atrial septal defects is limited to only a few isolated case reports because of uncertainty regarding safety and efficacy. Open-heart surgical repair remains the treatment of choice for coronary sinus atrial septal defects, although this may not be the only treatment option in selected cases. Herein we describe our own experience with two patients with different clinical presentations and our method of successful percutaneous coronary sinus atrial septal defect closure in each. We then present a review of the anatomic spectrum of coronary sinus atrial septal defects along with a review of contemporary surgical and percutaneous device treatment.

  4. 40 CFR 63.454 - Recordkeeping requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... defect or leak is not repaired within 15 days after discovery; (9) The expected date of successful repair of the defect or leak if the repair is not completed within 15 days; (10) The date of successful... 15 minutes. (f) The owner or operator of an open biological treatment system complying with § 63.453...

  5. 40 CFR 63.454 - Recordkeeping requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... defect or leak is not repaired within 15 days after discovery; (9) The expected date of successful repair of the defect or leak if the repair is not completed within 15 days; (10) The date of successful... 15 minutes. (f) The owner or operator of an open biological treatment system complying with § 63.453...

  6. Vacancy-type defects in Al2O3/GaN structure probed by monoenergetic positron beams

    NASA Astrophysics Data System (ADS)

    Uedono, Akira; Nabatame, Toshihide; Egger, Werner; Koschine, Tönjes; Hugenschmidt, Christoph; Dickmann, Marcel; Sumiya, Masatomo; Ishibashi, Shoji

    2018-04-01

    Defects in the Al2O3(25 nm)/GaN structure were probed by using monoenergetic positron beams. Al2O3 films were deposited on GaN by atomic layer deposition at 300 °C. Temperature treatment above 800 °C leads to the introduction of vacancy-type defects in GaN due to outdiffusion of atoms from GaN into Al2O3. The width of the damaged region was determined to be 40-50 nm from the Al2O3/GaN interface, and some of the vacancies were identified to act as electron trapping centers. In the Al2O3 film before and after annealing treatment at 300-900 °C, open spaces with three different sizes were found to coexist. The density of medium-sized open spaces started to decrease above 800 °C, which was associated with the interaction between GaN and Al2O3. Effects of the electron trapping/detrapping processes of interface states on the flat band voltage and the defects in GaN were also discussed.

  7. Higher surgeon annual volume, but not years of experience, is associated with reduced rates of postoperative complications and reoperations after open abdominal aortic aneurysm repair.

    PubMed

    Dubois, Luc; Allen, Britney; Bray-Jenkyn, Krista; Power, Adam H; DeRose, Guy; Forbes, Thomas L; Duncan, Audra; Shariff, Salimah Z

    2018-06-01

    Volume-outcome relationships for open abdominal aortic aneurysm (AAA) repair have received less attention in publicly funded health systems. Furthermore, the roles of surgeon seniority (years of experience) and composite volume (encompassing all major arterial cases) on outcomes after open AAA repair are less well known. We sought to determine the effects of surgeon volume, surgeon years of experience, and composite volume on outcomes after elective open AAA repairs performed in Ontario, Canada. Using a population-based, prospectively collected health administrative database, all elective open AAA repairs occurring in the province of Ontario from 2005 to 2014 were identified. Surgeon annual volume was classified by quintiles, with the highest volume quintile acting as the reference category. Multivariable logistic regression modeling was used, adjusting for patient factors (age, sex, comorbidities, year of procedure, income) to investigate the relationship between surgeon annual volume and 30-day mortality, 30-day major complications, 30-day reoperations, 1-year mortality, and 1-year reoperations (related to index procedure). The potential effects of annual surgeon composite volume and surgeon years of experience on postoperative outcomes were also explored. A total of 7211 elective open AAA repairs performed by 101 surgeons were identified between 2005 and 2014. Most of the operations were performed by vascular surgeons (81.5%), followed by cardiac (12.1%) and general surgeons (6.1%). Median number of procedures in the lowest quintile group was 3 repairs/y, whereas the highest quintile group performed 54 repairs/y. Overall 30-day mortality was 3%. No difference in mortality was detected in comparing the lowest with the highest volume groups (1.89% vs 3.01%; adjusted odds ratio [OR], 0.60; 95% confidence interval [CI], 0.27-1.33). The lowest volume group exhibited a higher 30-day complication rate (28.0% vs 20.4%; OR, 1.54; 95% CI, 1.15-2.06) and 30-day reoperation rate (10.53% vs 6.73%; OR, 1.64; 95% CI, 1.13-2.38) compared with the highest volume group. No effect of surgeon volume on 1-year mortality or 1-year reoperation was observed. Similarly, composite volume and surgeon years of experience were not associated with postoperative outcomes. In a single-payer system with a relatively high number of open AAA repairs/surgeon per year, surgeon annual volume had no effect on postoperative mortality but was associated with lower postoperative complication and reoperation rates. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  8. 7 CFR 51.1175 - Classification of defects.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Definitions § 51.1175 Classification of defects. Table I Factor Injury Damage Serious damage Very serious... mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of... 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other...

  9. 7 CFR 51.784 - Classification of defects.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Definitions § 51.784 Classification of defects. Table I Factor Injury Damage Serious damage Very serious.../4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or the equivalent of...

  10. 7 CFR 51.784 - Classification of defects.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Definitions § 51.784 Classification of defects. Table I Factor Injury Damage Serious damage Very serious.../4 inch (6.4 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/2 inch (12.7 mm) at stem end, or the equivalent of...

  11. 7 CFR 51.1837 - Classification of defects.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Definitions § 51.1837 Classification of defects. Table I Factor Damage Serious damage Very serious damage... segments more than 1/8 inch (3.2 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or...

  12. 7 CFR 51.1175 - Classification of defects.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Definitions § 51.1175 Classification of defects. Table I Factor Injury Damage Serious damage Very serious... mushy condition Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or the equivalent of... 1/2 inch (12.7 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other...

  13. 7 CFR 51.1837 - Classification of defects.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Definitions § 51.1837 Classification of defects. Table I Factor Damage Serious damage Very serious damage... segments more than 1/8 inch (3.2 mm) at stem end, or the equivalent of this amount, by volume, when occurring in other portions of the fruit Affecting all segments more than 1/4 inch (6.4 mm) at stem end, or...

  14. Synthesis and study of electrolytic materials with a high-energy defect structure and a developed surface

    NASA Astrophysics Data System (ADS)

    Gryzunova, N. N.; Vikarchuk, A. A.; Tyur'kov, M. N.

    2016-10-01

    The defect structure of the electrolytic copper coatings formed upon mechanical activation of a cathode is described. These coatings are shown to have a fragmented structure containing disclination-type defects, namely, terminating dislocation, disclination and twin boundaries; partial disclinations, misorientation bands; and twin layers. They have both growth and deformation origins. The mechanisms of formation of the structural defects are discussed. It is experimentally proved that part of the elastic energy stored in the crystal volume during electrocrystallization can be converted into surface energy. As a result, catalytically active materials with a large developed surface can be synthesized.

  15. Influence of Crystal Expansion/Contraction on Zeolite Membrane Permeation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sorenson, Stephanie G; Payzant, E Andrew; Noble, Richard D

    X-ray diffraction was used to measure the unit cell parameters of B-ZSM-5, SAPO-34, and NaA zeolite powders as a function of adsorbate loading at 303 K, and in one case, at elevated temperatures. Most adsorbates expanded the zeolite crystals below saturation loading at 303 K: n-hexane and SF6 in B-ZSM-5, methanol and CO2 in SAPO-34, and methanol in NaA zeolite. As the loadings increased, the crystals expanded more. Changes in the unit cell volumes of B-ZSM-5 and SAPO-34 zeolite powders correlated with changes in permeation through zeolite membranes defects. When the zeolite crystals expanded or contracted upon adsorption, the defectmore » sizes decreased or increased. In B-ZSM-5 membranes, the fluxes through defects decreased dramatically when n-hexane or SF6 adsorbed. In contrast, i-butane adsorption at 303 K contracted B-ZSM-5 crystals at low loadings and expanded them at higher loadings. Correspondingly, the flux through B-ZSM-5 membrane defects increased at low i-butane loadings and decreased at high loading because the defects increased in size at low loading and decreased at high loadings. At 398 K and 473 K, n-hexane expanded the B-ZSM-5 unit cell more as the temperature increased from 303 to 473 K. The silicalite-1 and B-ZSM-5 unit cell volumes expanded similarly upon n-hexane adsorption at 303 K; boron substitution had little effect on volume expansion.« less

  16. Neural tube defects – recent advances, unsolved questions and controversies

    PubMed Central

    Copp, Andrew J.; Stanier, Philip; Greene, Nicholas D. E.

    2014-01-01

    Neural tube defects (NTDs) are severe congenital malformations affecting around 1 in every 1000 pregnancies. Here we review recent advances and currently unsolved issues in the NTD field. An innovation in clinical management has come from the demonstration that closure of open spina bifida lesions in utero can diminish neurological dysfunction in children. Primary prevention by folic acid has been enhanced through introduction of mandatory food fortification in some countries, although not yet in UK. Genetic predisposition comprises the majority of NTD risk, and genes that regulate folate one-carbon metabolism and planar cell polarity have been strongly implicated. The sequence of human neural tube closure events remains controversial, but study of mouse NTD models shows that anencephaly, open spina bifida and craniorachischisis result from failure of primary neurulation, while skin-covered spinal dysraphism results from defective secondary neurulation. Other ‘NTD’ malformations, such as encephalocele, are likely to be post-neurulation disorders. PMID:23790957

  17. Multifocal visual evoked potentials for early glaucoma detection.

    PubMed

    Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W

    2012-07-01

    To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.

  18. Optimizing Soft Tissue Management and Spacer Design in Segmental Bone Defects

    DTIC Science & Technology

    2016-12-01

    proximal and distal bone segments. 3. Debride 10 grams of tibialis anterior and gastrocnemius muscles. 4. Place an interlocking intramedullary nail ...using a custom spacer to maintain 5-cm defect length. 5. Place a pre-molded 5 cm long x 2 cm diameter PMMA spacer around the nail in the defect. 6...tibia. 3. Open the IM surrounding the PMMA spacer using a “bomb bay door opening”. 4. Remove the spacer without damaging the membrane or nail . 5

  19. Defect-Engineered Metal–Organic Frameworks

    PubMed Central

    Fang, Zhenlan; Bueken, Bart; De Vos, Dirk E; Fischer, Roland A

    2015-01-01

    Defect engineering in metal–organic frameworks (MOFs) is an exciting concept for tailoring material properties, which opens up novel opportunities not only in sorption and catalysis, but also in controlling more challenging physical characteristics such as band gap as well as magnetic and electrical/conductive properties. It is challenging to structurally characterize the inherent or intentionally created defects of various types, and there have so far been few efforts to comprehensively discuss these issues. Based on selected reports spanning the last decades, this Review closes that gap by providing both a concise overview of defects in MOFs, or more broadly coordination network compounds (CNCs), including their classification and characterization, together with the (potential) applications of defective CNCs/MOFs. Moreover, we will highlight important aspects of “defect-engineering” concepts applied for CNCs, also in comparison with relevant solid materials such as zeolites or COFs. Finally, we discuss the future potential of defect-engineered CNCs. PMID:26036179

  20. Failure of mesenteric defect closure after Roux-en-Y gastric bypass.

    PubMed

    Hope, William W; Sing, Ronald F; Chen, Albert Y; Lincourt, Amy E; Gersin, Keith S; Kuwada, Timothy S; Heniford, B Todd

    2010-01-01

    Bowel obstructions following Roux-en-Y gastric bypass (RYGB) are a significant issue often caused by internal herniation. Controversy continues as to whether mesenteric defect closure is necessary to decrease the incidence of internal hernias after RYGB. Our purpose was to evaluate the effectiveness of closing the mesenteric defect at the jejunojejunostomy in patients who underwent RYGB by examining this potential space at reoperation for any reason. We retrospectively reviewed medical records of patients undergoing surgery after RYGB from August 1999 to October 2008 to determine the status of the mesentery at the jejunojejunostomy. Eighteen patients underwent surgery 2 to 19 months after open (n=8) or laparoscopic (n=10) RYGB. All patients had documented suture closure of their jejunojejunostomy at the time of RYGB. Permanent (n=12) or absorbable (n=6) sutures were used for closures. Patients lost 23.6 kg to 62.1 kg before a reoperation was required for a ventral hernia (n=8), cholecystectomy (n=4), abdominal pain (n=4), or small bowel obstruction (n=2). Fifteen of the 18 patients had open mesenteric defects at the jejunojejunostomy despite previous closure; none were the cause for reoperation. Routine suture closure of mesenteric defects after RYGB may not be an effective permanent closure likely due to the extensive fat loss and weight loss within the mesentery.

  1. Pharmacological Correction of Trafficking Defects in ATP-sensitive Potassium Channels Caused by Sulfonylurea Receptor 1 Mutations.

    PubMed

    Martin, Gregory M; Rex, Emily A; Devaraneni, Prasanna; Denton, Jerod S; Boodhansingh, Kara E; DeLeon, Diva D; Stanley, Charles A; Shyng, Show-Ling

    2016-10-14

    ATP-sensitive potassium (K ATP ) channels play a key role in mediating glucose-stimulated insulin secretion by coupling metabolic signals to β-cell membrane potential. Loss of K ATP channel function due to mutations in ABCC8 or KCNJ11, genes encoding the sulfonylurea receptor 1 (SUR1) or the inwardly rectifying potassium channel Kir6.2, respectively, results in congenital hyperinsulinism. Many SUR1 mutations prevent trafficking of channel proteins from the endoplasmic reticulum to the cell surface. Channel inhibitors, including sulfonylureas and carbamazepine, have been shown to correct channel trafficking defects. In the present study, we identified 13 novel SUR1 mutations that cause channel trafficking defects, the majority of which are amenable to pharmacological rescue by glibenclamide and carbamazepine. By contrast, none of the mutant channels were rescued by K ATP channel openers. Cross-linking experiments showed that K ATP channel inhibitors promoted interactions between the N terminus of Kir6.2 and SUR1, whereas channel openers did not, suggesting the inhibitors enhance intersubunit interactions to overcome channel biogenesis and trafficking defects. Functional studies of rescued mutant channels indicate that most mutants rescued to the cell surface exhibited WT-like sensitivity to ATP, MgADP, and diazoxide. In intact cells, recovery of channel function upon trafficking rescue by reversible sulfonylureas or carbamazepine was facilitated by the K ATP channel opener diazoxide. Our study expands the list of K ATP channel trafficking mutations whose function can be recovered by pharmacological ligands and provides further insight into the structural mechanism by which channel inhibitors correct channel biogenesis and trafficking defects. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  2. Laparoscopic versus open incisional hernia repair: a retrospective cohort study with costs analysis on 269 patients.

    PubMed

    Soliani, G; De Troia, A; Portinari, M; Targa, S; Carcoforo, P; Vasquez, G; Fisichella, P M; Feo, C V

    2017-08-01

    To compare clinical outcomes and institutional costs of elective laparoscopic and open incisional hernia mesh repairs and to identify independent predictors of prolonged operative time and hospital length of stay (LOS). Retrospective observational cohort study on 269 consecutive patients who underwent elective incisional hernia mesh repair, laparoscopic group (N = 94) and open group (N = 175), between May 2004 and July 2014. Operative time was shorter in the laparoscopic versus open group (p < 0.0001). Perioperative morbidity and mortality were similar in the two groups. Patients in the laparoscopic group were discharged a median of 2 days earlier (p < 0.0001). At a median follow-up over 50 months, no difference in hernia recurrence was detected between the groups. In laparoscopic group total institutional costs were lower (p = 0.02). At Cox regression analysis adjusted for potential confounders, large wall defect (W3) and higher operative risk (ASA score 3-4) were associated with prolonged operative time, while midline hernia site was associated with increased hospital LOS. Open surgical approach was associated with prolongation of both operative time and LOS. Laparoscopic approach may be considered safely to all patients for incisional hernia repair, regardless of patients' characteristics (age, gender, BMI, ASA score, comorbidities) and size of the wall defect (W2-3), with the advantage of shorter operating time and hospital LOS that yields reduced total institutional costs. Patients with higher ASA score and large hernia defects are at risk of prolonged operative time, while an open approach is associated with longer duration of surgical operation and hospital LOS.

  3. Facet Dependent Disorder in the Pristine High Voltage Lithium-Manganese-Rich Cathode Material

    DOE PAGES

    Dixit, Hemant M.; Zhou, Wu; Idrobo Tapia, Juan Carlos; ...

    2014-11-21

    Defects and surface reconstructions are thought to be crucial for the long term stability of high-voltage lithium-manganese-rich cathodes. Unfortunately, many of these defects arise only after electrochemical cycling which occur under harsh conditions making it difficult to fully comprehend the role they play in degrading material performance. Recently, it has been observed that defects are present even in the pristine material. This study, therefore, focuses on examining the nature of the disorder observed in pristine Limore » $$_{1.2}$$Ni$$_{0.175}$$Mn$$_{0.525}$$Co$$_{0.1}$$O$$_2$$ (LNMCO) particles. Using atomic resolution Z-contrast imaging and electron energy-loss spectroscopy measurements we show that there are indeed a significant amount of anti-site defects present in this material; with transition metals substituting on Li metal sites. Furthermore, we find a strong tendency of segregation of these types of defects towards open facets (surfaces perpendicular to the layered arrangement of atoms), rather than closed facets (surfaces parallel to the layered arrangement of atoms). First principles calculations identify anti-site defect pairs of Ni swapping with Li ions as the predominant defect in the material. Furthermore, energetically favorable swapping of Ni on the Mn sites were observed to lead to Mn depletion at open facets. Relatively, low Ni migration barriers also support the notion that Ni are the predominant cause of disorder. These insights suggests that certain facets of the LNMCO particles may be more useful for inhibiting surface reconstruction and improving the stability of these materials through careful consideration of the exposed surface.« less

  4. Aperiodic Volume Optics

    NASA Astrophysics Data System (ADS)

    Gerke, Tim D.

    Presented in this thesis is an investigation into aperiodic volume optical devices. The three main topics of research and discussion are the aperiodic volume optical devices that we call computer-generated volume holograms (CGVH), defects within periodic 3D photonic crystals, and non-periodic, but ordered 3D quasicrystals. The first of these devices, CGVHs, are designed and investigated numerically and experimentally. We study the performance of multi-layered amplitude computer-generated volume holograms in terms of efficiency and angular/frequency selectivity. Simulation results show that such aperiodic devices can increase diffraction efficiency relative to periodic amplitude volume holograms while maintaining angular and wavelength selectivity. CGVHs are also designed as voxelated volumes using a new projection optimization algorithm. They are investigated using a volumetric diffraction simulation and a standard 3D beam propagation technique as well as experimentally. Both simulation and experiment verify that the structures function according to their design. These represent the first diffractive structures that have the capacity for generating arbitrary transmission and reflection wave fronts and that provide the ability for multiplexing arbitrary functionality given different illumination conditions. Also investigated and discussed in this thesis are 3D photonic crystals and quasicrystals. We demonstrate that these devices can be fabricated using a femtosecond laser direct writing system that is particularly appropriate for fabrication of such arbitrary 3D structures. We also show that these devices can provide 3D partial bandgaps which could become complete bandgaps if fabricated using high index materials or by coating lower index materials with high index metals. Our fabrication method is particularly suited to the fabrication of engineered defects within the periodic or quasi-periodic systems. We demonstrate the potential for fabricating defects within periodic and quasi-periodic systems for the manipulation of light in the IR regime. The general thesis of this document is that aperiodic three-dimensional structures provide additional degrees of freedom that can be utilized to improve on the performance of periodic volume devices. The results we will discuss suggest that, under certain circumstances, a departure from the Bragg paradigm provides enhanced volume diffraction properties.

  5. Defect recognition in CFRP components using various NDT methods within a smart manufacturing process

    NASA Astrophysics Data System (ADS)

    Schumacher, David; Meyendorf, Norbert; Hakim, Issa; Ewert, Uwe

    2018-04-01

    The manufacturing process of carbon fiber reinforced polymer (CFRP) components is gaining a more and more significant role when looking at the increasing amount of CFRPs used in industries today. The monitoring of the manufacturing process and hence the reliability of the manufactured products, is one of the major challenges we need to face in the near future. Common defects which arise during manufacturing process are e.g. porosity and voids which may lead to delaminations during operation and under load. To find irregularities and classify them as possible defects in an early stage of the manufacturing process is of high importance for the safety and reliability of the finished products, as well as of significant impact from an economical point of view. In this study we compare various NDT methods which were applied to similar CFRP laminate samples in order to detect and characterize regions of defective volume. Besides ultrasound, thermography and eddy current, different X-ray methods like radiography, laminography and computed tomography are used to investigate the samples. These methods are compared with the intention to evaluate their capability to reliably detect and characterize defective volume. Beyond the detection and evaluation of defects, we also investigate possibilities to combine various NDT methods within a smart manufacturing process in which the decision which method shall be applied is inherent within the process. Is it possible to design an in-line or at-line testing process which can recognize defects reliably and reduce testing time and costs? This study aims to show up opportunities of designing a smart NDT process synchronized to the production based on the concepts of smart production (Industry 4.0). A set of defective CFRP laminate samples and different NDT methods were used to demonstrate how effective defects are recognized and how communication between interconnected NDT sensors and the manufacturing process could be organized.

  6. The quantum defect: Early history and recent developments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rau, A.R.; Inokuti, M.

    1997-03-01

    The notion of the quantum defect is important in atomic and molecular spectroscopy and also in unifying spectroscopy with collision theory. In the latter context, the quantum defect may be viewed as an ancestor of the phase shift. However, the origin of the term {open_quotes}quantum defect{close_quotes} does not seem to be explained in standard textbooks. It occurred in a 1921 paper by Schr{umlt o}dinger, preceding quantum mechanics, yet giving the correct meaning as an index of the short-range interactions with the core of an atom. We present the early history of the quantum-defect idea, and sketch its recent developments. {copyright}more » {ital 1997 American Association of Physics Teachers.}« less

  7. Systemic Teriparatide Administration Promotes Osseous Regeneration of an Intrabony Defect: A Case Report.

    PubMed

    Bashutski, Jill D; Kinney, Janet S; Benavides, Erika; Maitra, Samopriyo; Braun, Thomas M; Giannobile, William V; McCauley, Laurie K; Eber, Robert M

    2012-05-01

    Teriparatide comprises the first 34 amino acids of parathyroid hormone and is a systemic anabolic agent that is Food and Drug Administration approved for the treatment of osteoporosis but not for periodontitis. To our knowledge, this is the first clinical case report to document the treatment of a patient with severe periodontitis using an open-flap debridement procedure in conjunction with teriparatide. A 45-year-old female patient was diagnosed with severe chronic periodontitis, including the presence of an intrabony defect on tooth #6. She received open-flap debridement surgery in conjunction with daily systemic administration of 20 µg teriparatide, oral vitamin D, and calcium supplements for 6 weeks. Radiographic, clinical, gingival crevicular fluid (pyridinoline cross-linked carboxy-terminal propeptide of type I procollagen, procollagen type 1 N-propeptide, and osteocalcin), and serum parameters (parathyroid hormone, bone alkaline phosphatase, calcium, and 25-hydroxyvitamin D) were assessed. Treatment outcomes were evaluated over 4 years, with successful radiographic and clinical results throughout the follow-up period. Teriparatide administration in conjunction with traditional open-flap debridement surgery offers potential for the treatment of severe intrabony defects resulting from chronic periodontitis.

  8. A three-dimensional optimal sawing system for small sawmills in central Appalachia

    Treesearch

    Wenshu Lin; Jingxin Wang; R. Edward. Thomas

    2011-01-01

    A three-dimensional (3D) log sawing optimization system was developed to perform 3D log generation, opening face determination, sawing simulation, and lumber grading. Superficial characteristics of logs such as length, large-end and small-end diameters, and external defects were collected from local sawmills. Internal log defect positions and shapes were predicted...

  9. Clinical and radiographical evaluation of a bioresorbable collagen membrane of fish origin in the treatment of periodontal intrabony defects: A preliminary study.

    PubMed

    Santosh Kumar, B B; Aruna, D R; Gowda, Vinayak S; Galagali, Sushama R; Prashanthy, R; Navaneetha, H

    2013-09-01

    Recently, there has been interest in non-mammalian collagen sources such as fish collagen in periodontal regeneration. In the present study, collagen barrier membrane of fish origin was assessed in the treatment of periodontal intrabony defects. Ten systemically healthy chronic periodontitis patients having a paired osseous defect in the mandibular posterior teeth were selected and randomly assigned to receive a collagen membrane (test) or open flap debridement (control) in a split mouth design. Clinical parameters such as Plaque index, Gingival bleeding index, Probing pocket depth, Relative attachment level, and Recession were recorded at baseline, 3, 6, and at 9 months, while radiographic evaluation was done to assess alveolar crestal bone level and percentage of defect fill at 6 and 9 months using autoCAD 2007 software. Student's t test (two-tailed, dependent) was used to find the significance of study parameters on continuous scale. Significance was set at 5% level of significance. Wilcoxon signed rank test was used to find the significance of percentage change of defect fill. The comparison between the two groups did not show any statistically significant differences in the parameters assessed (P > 0.05) but, within each group, clinical parameters showed statistically significant differences from baseline to 9 months (P < 0.05). Within the limits of the study, it can be inferred that no significant differences were found either by using collagen membrane of fish origin or open flap debridement in the treatment of periodontal intrabony defects.

  10. Vision Algorithms Catch Defects in Screen Displays

    NASA Technical Reports Server (NTRS)

    2014-01-01

    Andrew Watson, a senior scientist at Ames Research Center, developed a tool called the Spatial Standard Observer (SSO), which models human vision for use in robotic applications. Redmond, Washington-based Radiant Zemax LLC licensed the technology from NASA and combined it with its imaging colorimeter system, creating a powerful tool that high-volume manufacturers of flat-panel displays use to catch defects in screens.

  11. Hidden topological constellations and polyvalent charges in chiral nematic droplets

    NASA Astrophysics Data System (ADS)

    Posnjak, Gregor; Čopar, Simon; Muševič, Igor

    2017-02-01

    Topology has an increasingly important role in the physics of condensed matter, quantum systems, material science, photonics and biology, with spectacular realizations of topological concepts in liquid crystals. Here we report on long-lived hidden topological states in thermally quenched, chiral nematic droplets, formed from string-like, triangular and polyhedral constellations of monovalent and polyvalent singular point defects. These topological defects are regularly packed into a spherical liquid volume and stabilized by the elastic energy barrier due to the helical structure and confinement of the liquid crystal in the micro-sphere. We observe, for the first time, topological three-dimensional point defects of the quantized hedgehog charge q=-2, -3. These higher-charge defects act as ideal polyvalent artificial atoms, binding the defects into polyhedral constellations representing topological molecules.

  12. Hidden topological constellations and polyvalent charges in chiral nematic droplets

    PubMed Central

    Posnjak, Gregor; Čopar, Simon; Muševič, Igor

    2017-01-01

    Topology has an increasingly important role in the physics of condensed matter, quantum systems, material science, photonics and biology, with spectacular realizations of topological concepts in liquid crystals. Here we report on long-lived hidden topological states in thermally quenched, chiral nematic droplets, formed from string-like, triangular and polyhedral constellations of monovalent and polyvalent singular point defects. These topological defects are regularly packed into a spherical liquid volume and stabilized by the elastic energy barrier due to the helical structure and confinement of the liquid crystal in the micro-sphere. We observe, for the first time, topological three-dimensional point defects of the quantized hedgehog charge q=−2, −3. These higher-charge defects act as ideal polyvalent artificial atoms, binding the defects into polyhedral constellations representing topological molecules. PMID:28220770

  13. Mitigation of substrate defects in reticles using multilayer buffer layers

    DOEpatents

    Mirkarimi, Paul B.; Bajt, Sasa; Stearns, Daniel G.

    2001-01-01

    A multilayer film is used as a buffer layer to minimize the size of defects on a reticle substrate prior to deposition of a reflective coating on the substrate. The multilayer buffer layer deposited intermediate the reticle substrate and the reflective coating produces a smoothing of small particles and other defects on the reticle substrate. The reduction in defect size is controlled by surface relaxation during the buffer layer growth process and by the degree of intermixing and volume contraction of the materials at the multilayer interfaces. The buffer layers are deposited at near-normal incidence via a low particulate ion beam sputtering process. The growth surface of the buffer layer may also be heated by a secondary ion source to increase the degree of intermixing and improve the mitigation of defects.

  14. Definition of mutually optimum NDI and proof test criteria for 2219 aluminum pressure vessels. Volume 3: Applications to rail defect evaluation

    NASA Technical Reports Server (NTRS)

    Schwartzberg, F. R.; Toth, C., Jr.; King, R. G.; Todd, P. H., Jr.

    1979-01-01

    The technique for inspection of railroad rails containing transverse fissure defects was discussed. Both pulse-echo and pitch-catch inspection techniques were used. The pulse-echo technique results suggest that a multiple-scan approach using varying angles of inclination, three-surface scanning, and dual-direction traversing may offer promise of characterization of transverse defects. Because each scan is likely to produce a reflection indicating only a portion of the defect, summing of the individual reflections must be used to obtain a reasonably complete characterization of the defect. The ability of the collimated pitch-catch technique to detect relatively small amounts of flaw growth was shown. The method has a problem in characterizing the portions of the defect near the top surface or web intersection. The work performed was a preliminary evaluation of the prospects for automated mapping of rail flaws.

  15. Subacute reconstruction of lower leg and foot defects due to high velocity-high energy injuries caused by gunshots, missiles, and land mines.

    PubMed

    Celiköz, Bahattin; Sengezer, Mustafa; Işik, Selçuk; Türegün, Murat; Deveci, Mustafa; Duman, Haluk; Acikel, Cengiz; Nişanci, Mustafa; Oztürk, Serdar

    2005-01-01

    The present study reviews 215 male patients suffering high velocity-high energy injuries of the lower leg or foot caused by war weapons such as missiles, gunshots, and land mines. They were treated in the Department of Plastic and Reconstructive Surgery at Gulhane Military Medical Academy (Ankara, Turkey) between November 1993-January 2001. Severe soft-tissue defects requiring flap coverage and associated open bone fractures that were treated 7-21 days (mean, 9.6 days) after the injury were included in the study. Twenty-three of 226 extremities (10.2%) underwent primary below-knee amputation. The number of debridements prior to definitive treatment was between 1-3 (mean, 1.9). Gustilo type III open tibia fractures accompanied 104 of 126 soft-tissue defects of the lower leg. Sixty-four bone defects accompanied 83 soft-tissue defects of the feet. Eighteen local pedicled muscle flaps and 208 free muscle flaps (latissimus dorsi, rectus abdominis, and gracilis) were used in soft-tissue coverage of 209 defects. Overall, the free muscle flap success rate was 91.3%. Bone defects were restored with 106 bone grafts, 25 free fibula flaps, and 14 distraction osteogenesis procedures. Osseous and soft-tissue defects were reconstructed simultaneously at the first definitive treatment in 94% of cases. The mean follow-up after definitive treatment was 25 (range, 9-47) months. The average full weight-bearing times for lower leg and feet injuries were 8.4 months and 4 months, respectively. Early, aggressive, and serial debridement of osseous and soft tissue, early restoration of bone and soft-tissue defects at the same stage, intensive rehabilitation, and patient education were the key points in the management of high velocity-high energy injuries of the lower leg and foot. copyright 2005 Wiley-Liss, Inc.

  16. Clinical differentiation of patent foramen ovale and secundum atrial septal defect: a survey of pediatric cardiologists in Dallas, Texas, USA.

    PubMed

    Scheuerle, Angela

    2011-01-01

    Public health birth defect surveillance registries rely on health care provider diagnosis and definition of congenital anomalies. Major anomalies are likely to have consistent diagnoses across providers; however, definition of some more common, often minor, defects can be problematic. Of particular frustration are the transient neonatal heart findings: patent ductus arteriosus, patent foramen ovale, and pulmonary artery branch stenosis. Under certain circumstances these findings may be considered true anomalies-patent foramen ovale (PFO) as a clinical finding overlaps significantly with atrial septal defect (ASD) of secundum type, the latter being considered a true congenital malformation. Some criteria must be established to separate these conditions in case ascertainment. It is therefore helpful to understand the clinical definitions of patent foramen ovale and secundum atrial septal defect. Pediatric cardiologists in the greater Dallas, Texas metropolitan area were surveyed by telephone, fax, and/or email and asked what criteria they use to distinguish a PFO from a secundum ASD. This was an open-ended question. No baseline parameters were suggested or introduced by the interviewer. Pediatric cardiology fellowship training was identified for each physician to examine the hypothesis that graduates of a given program would use the same diagnostic criteria. Responses were obtained from 22 of 23 pediatric cardiologists. Four measurement criteria were identified: size of the opening, presence or absence of a flap of septal tissue, appearance of the defect on echocardiogram and presence/absence/amount of blood shunting across through the opening. Though there was overlap, diagnostic criteria differentiating PFO and secundum ASD varied among pediatric cardiologists. Two fellowship programs were well represented by the respondent population. Eight respondents were trained at Fellowship 1 and 5 at Fellowship 2. Place of fellowship training was not a strong indicator of which diagnostic criteria were used, even when graduates were in practice together. Physicians in private practice were more likely to report objective measurements as bases for their diagnostic decision. The pronounced variability in clinical definitions will be a problem for birth defect surveillance and research based upon the resultant database. When different physicians use different diagnostic criteria for borderline defects, it is impossible to know whether a defect ascertained and coded with a standard protocol is the same across the population. Since it is unlikely that consistent diagnostic criteria can be put in place, the surveillance program is burdened with compensating for the variability.

  17. Advanced process and defect characterization methodology to support process development of advanced patterning structures

    NASA Astrophysics Data System (ADS)

    Ketkar, Supriya; Lee, Junhan; Asokamani, Sen; Cho, Winston; Mishra, Shailendra

    2018-03-01

    This paper discusses the approach and solution adopted by GLOBALFOUNDRIES, a high volume manufacturing (HVM) foundry, for dry-etch related edge-signature surface particle defects issue facing the sub-nm node in the gate-etch sector. It is one of the highest die killers for the company in the 14-nm node. We have used different approaches to attack and rectify the edge signature surface particle defect. Several process-related & hardware changes have been successively implemented to achieve defect reduction improvement by 63%. Each systematic process and/or hardware approach has its own unique downstream issues and they have been dealt in a route-cause-effect technique to address the issue.

  18. [Pedicle flap transfer combined with external fixator to treat leg open fracture with soft tissue defect].

    PubMed

    Luo, Zhongchun; Lou, Hua; Jiang, Junwei; Song, Chunlin; Gong, Min; Wang, Yongcai

    2008-08-01

    To investigate the clinical results of treating leg open fracture with soft tissue defect by pedicle flap transfer in combination with external fixator. From May 2004 to June 2007, 12 cases of leg open fracture with soft tissue defect, 9 males and 3 females aged 18-75 years, were treated. Among them, 8 cases were caused by traffic accidents, 2 crush, 1 falling and 1 mechanical accident. According to the Gustilo Classification, there were 2 cases of type II, 5 of type IIIA and 5 of type IIIB. There were 2 cases of upper-tibia fracture, 3 of middle-tibia and 7 of middle-lower. The sizes of soft tissue defect ranged from 5 cm x 3 cm to 22 cm x 10 cm.The sizes of exposed bone ranged from 3 cm x 2 cm to 6 cm x 3 cm. The course of the disease was 1-12 hours. Fracture fixation was reached by external fixators or external fixators and limited internal fixation with Kirschner wire. The wounds with exposed tendons and bones were repaired by ipsilateral local rotation flap, sural neurocutaneous flap and saphenous nerve flap. The size of selected flap ranged from 5 cm x 4 cm to 18 cm x 12 cm. Granulation wounds were repaired by skin grafting or direct suture. All patients were followed up for 6 months to 2 years. All patients survived, among whom 2 with the wound edge infection and 1 with the distal necrosis were cured by changing the dressing, 8 with pin hole infection were treated by taking out the external fixator, 1 with nonunion received fracture healing after bone graft in comminuted fracture of lower tibia, 2 suffered delayed union in middle-lower tibia fracture. The ROM of ankle in 3 cases was mildly poor with surpass-joint fixation, with plantar extension of 0-10 degrees and plantar flexion of 10-30 degrees, while the others had plantar extension of 10-20 degrees and plantar flexion of 30-50 degrees. The method of pedicle flap transfer combined with external fixator is safe and effective for the leg open fracture with soft tissue defect.

  19. Structural characterization of ZnO thin films grown on various substrates by pulsed laser deposition

    NASA Astrophysics Data System (ADS)

    Novotný, M.; Čížek, J.; Kužel, R.; Bulíř, J.; Lančok, J.; Connolly, J.; McCarthy, E.; Krishnamurthy, S.; Mosnier, J.-P.; Anwand, W.; Brauer, G.

    2012-06-01

    ZnO thin films were grown by pulsed laser deposition on three different substrates: sapphire (0 0 0 1), MgO (1 0 0) and fused silica (FS). The structure and morphology of the films were characterized by x-ray diffraction and scanning electron microscopy and defect studies were carried out using slow positron implantation spectroscopy (SPIS). Films deposited on all substrates studied in this work exhibit the wurtzite ZnO structure and are characterized by an average crystallite size of 20-100 nm. However, strong differences in the microstructure of films deposited on various substrates were found. The ZnO films deposited on MgO and sapphire single-crystalline substrates exhibit local epitaxy, i.e. a well-defined relation between film crystallites and the substrate. Domains with different orientation relationships with the substrate were found in both films. On the other hand, the film deposited on the FS substrate exhibits fibre texture with random lateral orientation of crystallites. Extremely high compressive in-plane stress of σ ˜ 14 GPa was determined in the film deposited on the MgO substrate, while the film deposited on sapphire is virtually stress-free, and the film deposited on the FS substrate exhibits a tensile in-plane stress of σ ˜ 0.9 GPa. SPIS investigations revealed that the concentration of open-volume defects in the ZnO films is substantially higher than that in a bulk ZnO single crystal. Moreover, the ZnO films deposited on MgO and sapphire single-crystalline substrates exhibit a significantly higher density of defects than the film deposited on the amorphous FS substrate.

  20. Theoretical calculations of positron annihilation characteristics in inorganic solids -- Recent advances and problems

    NASA Astrophysics Data System (ADS)

    Sob, M.; Sormann, H.; Kuriplach, J.

    Principles and applications of positron annihilation spectroscopy to electronic structure and defect studies are briefly reviewed and some recent advances and pending problems are illustrated by specific examples. In particular, it turns out that the sensitivity of calculated momentum densities of electron-positron annihilation pairs (MDAP) to the choice of electron crystal potential is higher or comparable to its sensitivity with respect to the choice of description of the electron-positron interaction. As a result, it is very hard to distinguish between various electron-positron interaction theories on the basis of the comparison of theoretical and experimental MDAPs. Furthermore, the positron affinity is determined theorttically for several systems having a band gap (semiconductors, insulators). It appears that the calculated positron affinities are significantly underestimated when compared to experimental data and, apparently, electron-positron interactions in such systems are not described satisfactorily by contemporary theoretical approaches. The above examples are related rather to electronic structure studies, but positrons are often used to investigate various open-volume defects in solids, which is dealt with in the last illustration. A non-selfconsistent computational technique suitable for the theoretical examination of configurations having large number (thousands) of non-equivalent atoms has been updated recently to treat non-periodic solids. It is based on the superposition of atomic densities in order to approximate the electronic density of the system studied. Though the charge redistribution due to selfconsistency effects is neglected, positron annihilation characteristics are determined quite reasonably. This allows for studying properties of extended defects like grain boundaries (and other interfaces), dislocations, precipitates, etc., which is very helpful when interpreting experimental positron annihilation data. Our technique is demonstrated for the case of nanocrystalline Ni where realistic atomic configurations are taken from large-scale molecular dynamics simulations.

  1. Defect studies in copper-based p-type transparent conducting oxides

    NASA Astrophysics Data System (ADS)

    Ameena, Fnu

    Among other intrinsic open-volume defects, copper vacancy (VCu) has been theoretically identified as the major acceptor in p-type Cu-based semiconducting transparent oxides, which has potential as low-cost photovoltaic absorbers in semi-transparent solar cells. A series of positron annihilation experiments with pure Cu, Cu2O, and CuO presented strong presence of VCu and its complexes in the copper oxides. The lifetime data also showed that the density of VCu was becoming higher as the oxidation state of Cu increased which was consistent with the decrease in the formation energy of VCu. Doppler broadening measurements further indicated that electrons with low momentum made more contribution to the contributed as pure Cu oxidizes to copper oxides. The metastable defects are known to be generated in Cu2O upon illumination and it has been known to affect the performance of Cu2O-based hetero-junctions used in solar cells. The metastable effect was studied using positron annihilation lifetime spectroscopy and its data showed the change in the defect population upon light exposure and the minimal effect of light-induced electron density increase in the bulk of materials to the average lifetime of the positrons. The change in the defect population is concluded to be related to the dissociation and association of VCu -- V Cu complexes. For example, the shorter lifetime under light was ascribed to the annihilation with smaller size vacancies, which explains the dissociation of the complexes with light illumination. Doppler broadening of the annihilation was independent of light illumination, which suggested that the chemical nature of the defects remained without change upon their dissociation and association -- only the size distribution of copper vacancies varied. The delafossite metal oxides, CuMIIIO2 are emerging wide-bandgap p-type semiconductors. In this research, the formation energies of structural vacancies are calculated using Van Vechten cavity model as an attempt to study the effect of the size of the MIII cation in the delafossites starting from Cu2O. Comparison of the formation energies between Cu2O and delafossite oxides clearly showed that the equilibrium concentration of the vacancies depended strongly on the structural parameters varied by the presence of different MIII cations. In particular, the size of the MIII cation greatly influenced the defect formation energies of VCu. It was observed from our calculations, as the size increases the formation energy decreases.

  2. Blood-Brain Barrier Closure Time After Controlled Ultrasound-Induced Opening Is Independent of Opening Volume.

    PubMed

    O'Reilly, Meaghan A; Hough, Olivia; Hynynen, Kullervo

    2017-03-01

    Microbubble-mediated focused ultrasound (US) opening of the blood-brain barrier (BBB) has shown promising results for the treatment of brain tumors and conditions such as Alzheimer disease. Practical clinical implementation of focused US treatments would aim to treat a substantial portion of the brain; thus, the safety of opening large volumes must be investigated. This study investigated whether the opened volume affects the time for the BBB to be restored after treatment. Sprague Dawley rats (n = 5) received bilateral focused US treatments. One hemisphere received a single sonication, and the contralateral hemisphere was targeted with 4 overlapping foci. Contrast-enhanced T1-weighted magnetic resonance imaging was used to assess the integrity of the BBB at 0, 6, and 24 hours after focused US. At time 0, there was no significant difference in the mean enhancement between the single- and multi-point sonications (mean ± SD, 29.7% ± 18.4% versus 29.7% ± 24.1%; P = .9975). The mean cross-sectional area of the BBB opening resulting from the multi-point sonication was approximately 3.5-fold larger than that of the single-point case (14.2 ± 4.7 versus 4.1 ± 3.3 mm 2 ; P < .0001). The opened volumes in 9 of 10 hemispheres were closed by 6 hours after focused US. The remaining treatment location had substantially reduced enhancement at 6 hours and was closed by 24 hours. Histologic analysis revealed small morphologic changes associated with this location. T2-weighted images at 6 and 24 hours showed no signs of edema. T2*-weighted images obtained at 6 hours also showed no signs hemorrhage in any animal. The time for the BBB to close after focused US was independent of the opening volume on the time scale investigated. No differences in treatment effects were observable by magnetic resonance imaging follow-up between larger- and smaller-volume sonications, suggesting that larger-volume BBB opening can be performed safely. © 2017 by the American Institute of Ultrasound in Medicine.

  3. Assessment of local variability by high-throughput e-beam metrology for prediction of patterning defect probabilities

    NASA Astrophysics Data System (ADS)

    Wang, Fuming; Hunsche, Stefan; Anunciado, Roy; Corradi, Antonio; Tien, Hung Yu; Tang, Peng; Wei, Junwei; Wang, Yongjun; Fang, Wei; Wong, Patrick; van Oosten, Anton; van Ingen Schenau, Koen; Slachter, Bram

    2018-03-01

    We present an experimental study of pattern variability and defectivity, based on a large data set with more than 112 million SEM measurements from an HMI high-throughput e-beam tool. The test case is a 10nm node SRAM via array patterned with a DUV immersion LELE process, where we see a variation in mean size and litho sensitivities between different unique via patterns that leads to a seemingly qualitative differences in defectivity. The large available data volume enables further analysis to reliably distinguish global and local CDU variations, including a breakdown into local systematics and stochastics. A closer inspection of the tail end of the distributions and estimation of defect probabilities concludes that there is a common defect mechanism and defect threshold despite the observed differences of specific pattern characteristics. We expect that the analysis methodology can be applied for defect probability modeling as well as general process qualification in the future.

  4. [Effect of ginsenoside Rb1 on cerebral infarction volume and IL-1 beta in the brain tissue and sera of focal cerebral ischemia/reperfusion injury model rats].

    PubMed

    Liu, Jun-Wei; Ren, Ye-Long; Liu, Xu-Ling; Xia, Hong-Lian; Zhang, Hui-Ling; Jin, Shen-Hui; Dai, Qin-Xue; Wang, Jun-Lu

    2013-12-01

    To investigate the effect of ginsenoside Rb1 on cerebral infarction volume as well as IL-1 beta in the brain tissue and sera of focal cerebral ischemia/reperfusion (I/R) injury model rats. The I/R rat model was established by using thread according to Zea-Longa. SD rats were randomly divided into five groups, i.e., the sham-operation group, the model group, the low dose ginsenoside Rb1 (20 mg/kg) group, the medium dose ginsenoside Rb1 group (40 mg/kg), and the high dose ginsenoside Rb1 group (80 mg/kg), 12 in each group. Rats in the sham-operation group only received middle cerebral artery occlusion (MCAO) but without thread insertion. The MCAO model was prepared in the rest 4 groups, followed by MCAO2 h later. Ginsenoside Rb1 at each dose was peritoneally administrated to rats in corresponding groups immediately after cerebral ischemia. Equal volume of normal saline was administered to rats in the sham-operation group. Rats' cerebral infarction volume, integrals of neurologic defect degree, expression of IL-1 beta content in the brain tissue and sera were observed 24 h after 2-h cerebral I/R. In the model group, integrals of neurologic defect degree were improved (P < 0.01), IL-1 beta positive cells in the brain tissue increased and serum IL-1 beta content elevated (P < 0.05), when compared with the sham-operation group. In comparison of the model group, integrals of neurologic defect degree were lowered in the medium dose and high dose ginsenoside Rb1 groups (P < 0.05, P < 0.01). The cerebral infarction volume was all shrunken in each ginsenoside Rb1 group, IL-1 beta positive cells in the brain tissue decreased, and IL-1 beta content in serum reduced (P < 0.01, P < 0.05). Compared with the low dose ginsenoside Rb1 group, integrals of neurologic defect degree decreased, the cerebral infarction volume shrunken, and IL-1 beta content in serum reduced in the high dose ginsenoside Rb1 group (P < 0.01, P < 0.05). Ginsenoside Rb1 (20, 40, 80 mg/kg) might effectively release local cerebral ischemia by down-regulating the IL-1 beta expression.

  5. Assessment of angiogenesis in osseointegration of a silica-collagen biomaterial using 3D-nano-CT.

    PubMed

    Alt, Volker; Kögelmaier, Daniela Vera; Lips, Katrin S; Witt, Vera; Pacholke, Sabine; Heiss, Christian; Kampschulte, Marian; Heinemann, Sascha; Hanke, Thomas; Thormann, Ulrich; Schnettler, Reinhard; Langheinrich, Alexander C

    2011-10-01

    Bony integration of biomaterials is a complex process in which angiogenesis plays a crucial role. We evaluated micro- and nano-CT imaging to demonstrate and quantify neovascularization in bony integration of a biomaterial and to give an image based estimation for the needed resolution for imaging angiogenesis in an animal model of femora defect healing. In 8 rats 5mm full-size defects were created at the left femur that was filled with silica-collagen bone substitute material and internally fixed with plate osteosynthesis. After 6 weeks the femora were infused in situ with Microfil, harvested and scanned for micro-CT (9 μm)(3) and nano-CT (3 μm)(3) imaging. Using those 3D images, the newly formed blood vessels in the area of the biomaterial were assessed and the total vascular volume fraction, the volume of the bone substitute material and the volume of the bone defect were quantitatively characterized. Results were complemented by histology. Differences were statistically assessed using (ANOVA). High-resolution nano-CT demonstrated new blood vessel formation surrounding the biomaterial in all animals at capillary level. Immunohistochemistry confirmed the newly formed blood vessels surrounding the bone substitute material. The mean vascular volume fraction (VVF) around the implant was calculated to be 3.01 ± 0.4%. The VVF was inversely correlated with the volume of the bone substitute material (r=0.8) but not with the dimension of the fracture zone (r=0.3). Nano-CT imaging is feasible for quantitative analysis of angiogenesis during bony integration of biomaterials and a promising tool in this context for the future. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  6. Intra-articular administration of hyaluronic acid increases the volume of the hyaline cartilage regenerated in a large osteochondral defect by implantation of a double-network gel.

    PubMed

    Fukui, Takaaki; Kitamura, Nobuto; Kurokawa, Takayuki; Yokota, Masashi; Kondo, Eiji; Gong, Jian Ping; Yasuda, Kazunori

    2014-04-01

    Implantation of PAMPS/PDMAAm double-network (DN) gel can induce hyaline cartilage regeneration in the osteochondral defect. However, it is a problem that the volume of the regenerated cartilage tissue is gradually reduced at 12 weeks. This study investigated whether intra-articular administration of hyaluronic acid (HA) increases the volume of the cartilage regenerated with the DN gel at 12 weeks. A total of 48 rabbits were used in this study. A cylindrical osteochondral defect created in the bilateral femoral trochlea was treated with DN gel (Group DN) or left without any implantation (Group C). In both Groups, we injected 1.0 mL of HA in the left knee, and 1.0 mL of saline solution in the right knee. Quantitative histological evaluations were performed at 2, 4, and 12 weeks, and PCR analysis was performed at 2 and 4 weeks after surgery. In Group DN, the proteoglycan-rich area was significantly greater in the HA-injected knees than in the saline-injected knees at 12 weeks (P = 0.0247), and expression of type 2 collagen, aggrecan, and Sox9 mRNAs was significantly greater in the HA-injected knees than in the saline-injected knees at 2 weeks (P = 0.0475, P = 0.0257, P = 0.0222, respectively). The intra-articular administration of HA significantly enhanced these gene expression at 2 weeks and significantly increased the volume of the hyaline cartilage regenerated by implantation of a DN gel at 12 weeks. This information is important to develop an additional method to increase the volume of the hyaline cartilage tissue in a potential cartilage regeneration strategy using the DN gel.

  7. Method and apparatus for electrokinetic transport

    NASA Technical Reports Server (NTRS)

    James, Patrick Ismail (Inventor); Stejic, George (Inventor)

    2012-01-01

    Controlled electrokinetic transport of constituents of liquid media can be achieved by connecting at least two volumes containing liquid media with at least one dielectric medium with opposing dielectric surfaces in direct contact with said liquid media, and establishing at least one conduit across said dielectric medium, with a conduit inner surface surrounding a conduit volume and at least a first opening and a second opening opposite to the first opening. The conduit is arranged to connect two volumes containing liquid media and includes a set of at least three electrodes positioned in proximity of the inner conduit surface. A power supply is arranged to deliver energy to the electrodes such that time-varying potentials inside the conduit volume are established, where the superposition of said potentials represents at least one controllable traveling potential well that can travel between the opposing conduit openings.

  8. Provider Experience and the Comparative Safety of Laparoscopic and Open Colectomy.

    PubMed

    Sheetz, Kyle H; Norton, Edward C; Birkmeyer, John D; Dimick, Justin B

    2017-02-01

    To evaluate the comparative safety of laparoscopic and open colectomy across surgeons varying in experience with laparoscopy. National Medicare data (2008-2010) for beneficiaries undergoing laparoscopic or open colectomy. Using instrumental variable methods to address selection bias, we evaluated outcomes of laparoscopic and open colectomy. Our instrument was the regional use of laparoscopy in the year prior to a patient's operation. We then evaluated outcomes stratified by surgeons' annual volume of laparoscopic colectomy. Laparoscopic colectomy was associated with lower mortality (OR: 0.75, 95 percent CI: 0.70-0.78) and fewer complications than open surgery (OR: 0.82, 95 percent CI: 0.79-0.85). Increasing surgeon volume was associated with better outcomes for both procedures, but the relationship was stronger for laparoscopy. The comparative safety depended on surgeon volume. High-volume surgeons had 40 percent lower mortality (OR: 0.60, 95 percent CI: 0.55-0.65) and 30 percent fewer complications (OR: 0.70, 95 percent CI: 0.67-0.74) with laparoscopy. Conversely, low-volume surgeons had 7 percent higher mortality (OR: 1.07, 95 percent CI: 1.02-1.13) and 18 percent more complications (OR: 1.18, 95 percent CI: 1.12-1.24) with laparoscopy. This population-based study demonstrates that the comparative safety of laparoscopic and open colectomy is influenced by surgeon volume. Laparoscopic colectomy is only safer for patients whose surgeons have sufficient experience. © Health Research and Educational Trust.

  9. A structural model of age, grey matter volumes, education, and personality traits.

    PubMed

    Kitamura, Soichiro; Yasuno, Fumihiko; Yamamoto, Akihide; Kazui, Hiroaki; Kudo, Takashi; Matsuoka, Kiwamu; Kiuchi, Kuniaki; Kosaka, Jun; Nagatsuka, Kazuyuki; Iida, Hidehiro; Kishimoto, Toshifumi

    2016-01-01

    When the relationship between ageing and changes in personality traits is considered, it is important to know how they are influenced by biological and environmental factors. The present study examined the relationships between various factors associated with the effect of ageing on personality traits, including structural changes of the brain and environmental factors such as education. We recruited 41 healthy subjects. We administered the NEO Five-Factor Inventory to assess personality factors. Magnetic resonance imaging was performed, and regional grey matter (GM) volumes were obtained. We identified associations in the correlation analysis of age, cerebral GM volume, years of education, and the personality trait of openness. Path analysis was used to estimate the relationships among these factors. The path analysis model of age, GM volume, years of education, and the personality trait of openness revealed that age has an indirect negative association with openness through GM volume and years of education. Ageing was related to a decrease in GM volume, which was in turn related to a decrease in the openness score. Older subjects generally had fewer years of education, which was related to a lower openness score. Maintaining openness against the effects of ageing is desirable, and our results imply that interventions against age-related cerebral atrophy and the promotion of opportunities for higher education may contribute to the development and stability of a healthy personality during the adult life course. © 2015 The Authors. Psychogeriatrics © 2015 Japanese Psychogeriatric Society.

  10. Nucleation and growth of sodium colloids in NaCl under irradiation: theory and experiment

    NASA Astrophysics Data System (ADS)

    Dubinko, V. I.; Turkin, A. A.; Abyzov, A. S.; Sugonyako, A. V.; Vainshtein, D. I.; den Hartog, H. W.

    2005-01-01

    A mechanism of radiation-induced emission of Schottky defects from extended defects proposed originally for metals has recently been applied to ionic crystals, where it is based on interactions of excitons with extended defects such as dislocations and colloids. Exciton trapping and decay at colloids may result in the emission of F centers and consequent shrinkage of the colloid. In the present paper, the radiation-induced emission of F centers is taken into account in the modeling of nucleation and growth of sodium colloids and chlorine bubbles in NaCl exposed to electron or gamma irradiation. The evolution of colloid and bubble number densities and volume fractions with increasing irradiation dose is modeled in the framework of a modified rate theory and compared with experimental data. Experimental values of the colloid volume fractions and number densities have been estimated on the basis of latent heat of melting of metallic Na obtained with combined differential scanning calorimetry experiments and atomic force microscopy investigations of metallic clusters.

  11. Effect of Low-Intensity Pulsed Ultrasound after Mesenchymal Stromal Cell Injection to Treat Osteochondral Defects: An In Vivo Study.

    PubMed

    Yamaguchi, Shoki; Aoyama, Tomoki; Ito, Akira; Nagai, Momoko; Iijima, Hirotaka; Tajino, Junichi; Zhang, Xiangkai; Wataru, Kiyan; Kuroki, Hiroshi

    2016-12-01

    We investigated the effect of low-intensity pulsed ultrasound (LIPUS) treatment combined with mesenchymal stromal cell (MSC) injection for cartilage repair and subchondral bone reconstitution for treatment of osteochondral defects. An osteochondral defect was created on both femur grooves of Wistar rats. Four weeks later, bone marrow MSCs were injected into the right knee joint. The rats were divided into two intervention groups: without or with LIPUS irradiation. Cartilage repair was evaluated histologically based on the Wakitani cartilage repair score. Subchondral bone reconstitution was evaluated as bone volume (BV)/tissue volume (TV) by micro-computed tomography analysis. MSC injection improved the cartilage repair score, and LIPUS irradiation improved BV/TV. Combination treatment promoted both cartilage repair and BV/TV improvement. Thus, MSC injection combined with LIPUS irradiation is more effective than either treatment alone in promoting concurrent cartilage repair and subchondral reconstitution. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  12. Perforator based rectus free tissue transfer for head and neck reconstruction: New reconstructive advantages from an old friend.

    PubMed

    Kang, Stephen Y; Spector, Matthew E; Chepeha, Douglas B

    2017-11-01

    To demonstrate three reconstructive advantages of the perforator based rectus free tissue transfer: long pedicle, customizable adipose tissue, and volume reconstruction without muscle atrophy within a contained space. Thirty patients with defects of the head and neck were reconstructed with the perforator based rectus free tissue transfer. Transplant success was 93%. Mean pedicle length was 13.4cm. Eleven patients (37%) had vessel-poor necks and the long pedicle provided by this transplant avoided the need for vein grafts in these patients. Adipose tissue was molded in 17 patients (57%). Twenty-five patients (83%) had defects within a contained space, such as the orbit, where it was critical to have a transplant that avoided muscle atrophy. The perforator based rectus free tissue transfer provides a long pedicle, moldable fat for flap customization, and is useful in reconstruction of defects within a contained space where volume loss due to muscle atrophy is prevented. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Digital volume tomography in the diagnosis of periodontal defects: an in vitro study on native pig and human mandibles.

    PubMed

    Mengel, Reiner; Candir, Muhsin; Shiratori, Kiyoshi; Flores-de-Jacoby, Lavin

    2005-05-01

    The aim of this study of native pig and human mandibles was to investigate the accuracy and quality of the representation of periodontal defects by intraoral radiography (IR), panoramic radiography (PR), computed tomography (CT), and digital volume tomography (DVT) in comparison with histologic specimens. Following the standardized preparation of periodontal defects (14 dehiscences, fenestrations, 2- to 3-walled intrabony defects, respectively; Class I, II, and III furcation involvement) in six pig and seven human mandibles, IR, PR, CT, and DVT were performed. The histologic specimens were produced by cutting blocks with the individual defects out of the mandibles, embedding them in acrylic, and producing sagittal and axial microsections. The intrabony defects were measured using appropriate software on the digitized IR and PR images programs. The histologic sections were measured by reflecting stereomicroscopy. The statistical comparison between the measurements of the radiographic images and those of the histologic specimens was performed with Pearson's correlation coefficient. The quality of the radiographic images was determined through the subjective perception and detectability of the intrabony defects by five independent observers. All intrabony defects could be measured in three planes in the CT and DVT scans. Comparison with the histologic specimens yielded a mean deviation of 0.16 +/- 0.10 mm for the CT scans and 0.19 +/- 0.11 mm for the DVT scans. On the IR and PR images, the defects could be detected only in the mesio-distal and craniocaudal planes. In comparison with the histologic specimens, the IR images revealed a mean deviation of 0.33 +/- 0.18 mm and the PR images a mean deviation of 1.07 +/- 0.62 mm. The quality rating of the radiographic images was highest for the DVT scans. Overall, the CT and DVT scans displayed only a slight deviation in the extent of the periodontal defects in comparison with the histologic specimens. Both radiographic imaging techniques permitted imaging of anatomic osseous structures in three planes, true to scale, and without overlay or distortion. The DVT scans showed the best imaging quality.

  14. Postreplication Repair of Ultraviolet Damage in Haemophilus influenzae

    PubMed Central

    Leclerc, J. Eugene; Setlow, Jane K.

    1972-01-01

    The deoxyribonucleic acid (DNA) synthesized following ultraviolet (UV) irradiation of wild-type (Rd) and recombination-defective strains of Haemophilus influenzae has been analyzed by alkaline sucrose gradient sedimentation. Strain Rd and a UV-resistant, recombination-defective strain Rd(DB117) rec− are able to carry out postreplication repair, i.e., close the single-strand gaps in the newly synthesized DNA; in the UV-sensitive, recombination-defective strain DB117, the gaps remain open. The lack of postreplication repair in this strain may be the result of degradation of the newly synthesized DNA. PMID:4537422

  15. Method of radiographic inspection of wooden members

    NASA Technical Reports Server (NTRS)

    Berry, Maggie L. (Inventor); Berry, Robert F., Jr. (Inventor)

    1990-01-01

    The invention is a method to be used for radiographic inspection of a wooden specimen for internal defects which includes the steps of introducing a radiopaque penetrant into any internal defects in the specimen through surface openings; passing a beam of radiation through a portion of the specimen to be inspected; and making a radiographic film image of the radiation passing through the specimen, with the radiopaque penetrant in the specimen absorbing the radiation passing through it, thereby enhancing the resulting image of the internal defects in the specimen.

  16. European Software Engineering Process Group Conference (2nd Annual), EUROPEAN SEPG󈨥. Delegate Material, Conference

    DTIC Science & Technology

    1997-06-19

    states, and six of the top ten suppliers of software with the lowest defect levels are also EU member states Kerry Hanson, Director TI ex White House OST...6,M 0"M *" changes Defects reported by customers STeraQuest S ofOR Wednsday 18 Jlue (C303) 5-3 lE’s IDEAL Model organizational analyze lss.ons exeute...Indicator used to track non discretionary maintenance, enhancements, and defect corrections as well as the number of open trouble reports. 17 *Enterprise

  17. Defect-enhanced void filling and novel filled phases of open-structure skutterudites

    DOE PAGES

    Xi, Lili; Qiu, Yuting; Shi, Xun; ...

    2015-05-14

    Here, we report the design of novel filled CoSb 3 skutterudite phases based on a combination of filling and Sb-substituted Ga/In defects. Ga/In doped skutterudite phases with Li-, Nd-, and Sm-fillings can be formed via this strategy, which can have relatively wider ranges of carrier concentration than other conventional filled skutterudite phases.

  18. Effect of cementum defects on radicular penetration of 30% H2O2 during intracoronal bleaching.

    PubMed

    Rotstein, I; Torek, Y; Misgav, R

    1991-05-01

    Bleaching pulpless teeth with 30% hydrogen peroxide has been reported to cause external cervical root resorption. It has been hypothesized that H2O2 penetrating through open dentin tubules can initiate an inflammatory reaction which could result in root resorption. Extracted human premolars were treated endodontically and bleached intracoronally using the thermocatalytic technique. The teeth were divided into three groups; one group with no cementum defects at the cementoenamel junction, one group with artificial cementum defects at the cementoenamel junction, and another group with artificial cementum defects at the middle third of the root. The radicular penetration of 30% hydrogen peroxide in the three groups was assessed directly and compared using an in vitro model. Radicular penetration of hydrogen peroxide was found in all of the groups tested. The penetration of hydrogen peroxide was significantly higher in teeth with cementum defects at the cementoenamel junction than in those without defects.

  19. Hydrogen-Induced Plastic Deformation in ZnO

    NASA Astrophysics Data System (ADS)

    Lukáč, F.; Čížek, J.; Vlček, M.; Procházka, I.; Anwand, W.; Brauer, G.; Traeger, F.; Rogalla, D.; Becker, H.-W.

    In the present work hydrothermally grown ZnO single crystals covered with Pd over-layer were electrochemically loaded with hydrogen and the influence of hydrogen on ZnO micro structure was investigated by positron annihilation spectroscopy (PAS). Nuclear reaction analysis (NRA) was employed for determination of depth profile of hydrogen concentration in the sample. NRA measurements confirmed that a substantial amount of hydrogen was introduced into ZnO by electrochemical charging. The bulk hydrogen concentration in ZnO determined by NRA agrees well with the concentration estimated from the transported charge using the Faraday's law. Moreover, a subsurface region with enhanced hydrogen concentration was found in the loaded crystals. Slow positron implantation spectroscopy (SPIS) investigations of hydrogen-loaded crystal revealed enhanced concentration of defects in the subsurface region. This testifies hydrogen-induced plastic deformation of the loaded crystal. Absorbed hydrogen causes a significant lattice expansion. At low hydrogen concentrations this expansion is accommodated by elastic straining, but at higher concentrations hydrogen-induced stress exceeds the yield stress in ZnO and plastic deformation of the loaded crystal takes place. Enhanced hydrogen concentration detected in the subsurface region by NRA is, therefore, due to excess hydrogen trapped at open volume defects introduced by plastic deformation. Moreover, it was found that hydrogen-induced plastic deformation in the subsurface layer leads to typical surface modification: formation of hexagonal shape pyramids on the surface due to hydrogen-induced slip in the [0001] direction.

  20. Open abdomen critical care management principles: resuscitation, fluid balance, nutrition, and ventilator management

    PubMed Central

    Chabot, Elizabeth; Nirula, Ram

    2017-01-01

    The term “open abdomen” refers to a surgically created defect in the abdominal wall that exposes abdominal viscera. Leaving an abdominal cavity temporarily open has been well described for several indications, including damage control surgery and abdominal compartment syndrome. Although beneficial in certain patients, the act of keeping an abdominal cavity open has physiologic repercussions that must be recognized and managed during postoperative care. This review article describes these issues and provides guidelines for the critical care physician managing a patient with an open abdomen. PMID:29766080

  1. Birth outcomes among military personnel after exposure to documented open-air burn pits before and during pregnancy.

    PubMed

    Conlin, Ava Marie S; DeScisciolo, Connie; Sevick, Carter J; Bukowinski, Anna T; Phillips, Christopher J; Smith, Tyler C

    2012-06-01

    To examine birth outcomes in military women and men with potential exposure to documented open-air burn pits before and during pregnancy. Electronic data from the Department of Defense Birth and Infant Health Registry and the Defense Manpower Data Center were used to examine the prevalence of birth defects and preterm birth among infants of active-duty women and men who were deployed within a 3-mile radius of a documented open-air burn pit before or during pregnancy. In general, burn pit exposure at various times in relation to pregnancy and for differing durations was not consistently associated with an increase in birth defects or preterm birth in infants of active-duty military personnel. These analyses offer reassurance to service members that burn pit exposure is not consistently associated with these select adverse infant health outcomes.

  2. Continuous delivery of rhBMP2 and rhVEGF165 at a certain ratio enhances bone formation in mandibular defects over the delivery of rhBMP2 alone--An experimental study in rats.

    PubMed

    Lohse, N; Moser, N; Backhaus, S; Annen, T; Epple, M; Schliephake, H

    2015-12-28

    The aim of the present study was to test the hypothesis that different amounts of vascular endothelial growth factor and bone morphogenic protein differentially affect bone formation when applied for repair of non-healing defects in the rat mandible. Porous composite PDLLA/CaCO3 carriers were fabricated as slow release carriers and loaded with rhBMP2 and rhVEGF165 in 10 different dosage combinations using gas foaming with supercritical carbon dioxide. They were implanted in non-healing defects of the mandibles of 132 adult Wistar rats with additional lateral augmentation. Bone formation was assessed both radiographically (bone volume) and by histomorphometry (bone density). The use of carriers with a ratio of delivery of VEGF/BMP between 0.7 and 1.2 was significantly related to the occurrence of significant increases in radiographic bone volume and/or histologic bone density compared to the use of carriers with a ratio of delivery of ≤ 0.5 when all intervals and all outcome parameters were considered. Moreover, simultaneous delivery at this ratio helped to "save" rhBMP2 as both bone volume and bone density after 13 weeks were reached/surpassed using half the dosage required for rhBMP2 alone. It is concluded, that the combined delivery of rhVEGF165 and rhBMP2 for repair of critical size mandibular defects can significantly enhance volume and density of bone formation over delivery of rhBMP2 alone. It appears from the present results that continuous simultaneous delivery of rhVEGF165 and rhBMP2 at a ratio of approximately 1 is favourable for the enhancement of bone formation. Copyright © 2015. Published by Elsevier B.V.

  3. Calvarial defect reconstruction.

    PubMed

    Jimenez, D F; Barone, C M

    1994-04-01

    The history of skull trepanation is almost as old as that of humanity. For thousands of years it has been performed for the treatment of numerous medical maladies. The Andean Incas, early Asians and South Seas Islanders, are amongst the many people to perform calvarial trepanation. Hippocrates described techniques for the use of the trepan in early Greek times. With the production of a skull opening comes the challenge of developing methods for closing the defect. It is in reality, more challenging to repair the defect than to create it. Man, with his never ending ingenuity, has tried to develop many techniques. We will discuss some of them and present our method of choice for closure of skull defects.

  4. The relationship between hippocampal volume and static postural sway: results from the GAIT study.

    PubMed

    Beauchet, Olivier; Barden, John; Liu-Ambrose, Teresa; Chester, Victoria L; Szturm, Tony; Allali, Gilles

    2016-02-01

    The role of the hippocampus in postural control, in particular in maintaining upright stance, has not been fully examined in normal aging. This study aims to examine the association of postural sway with hippocampal volume while maintaining upright stance in healthy older individuals. Seventy healthy individuals (mean age 69.7 ± 3.4 years; 41.4 % women) were recruited in this study based on cross-sectional design. Hippocampal volume (quantified from a three-dimensional T1-weighted MRI using semi-automated software), three center of pressure (COP) motion parameters (sway area, path length of anterior-posterior (AP) and medial-lateral (ML) displacement) while maintaining upright stance (eyes open and closed), and the relative difference between open and closed eye conditions were used as outcome measures. Age, sex, body mass index, lower limb proprioception, distance vision, 15-item geriatric depression scale score, total cranial volume, and white matter abnormalities were used as covariates. The sway area decreased from open to closed eye condition but this variation was non-significant (P = 0.244), whereas path length of AP and ML displacement increased significantly (P < 0.003). Increase in sway area from open to closed eyes was associated with greater hippocampal volume (β -18.21; P = 0.044), and a trend for an association of increase in path length of AP displacement (P = 0.075 for open eyes and P = 0.071 for closed eyes) with greater hippocampal volume was reported. The hippocampus is involved in upright postural control in normal aging, such that an increase in sway area of COP motion from open to closed eyes is associated with greater hippocampal volume in healthy older adults.

  5. Mandibular kinematics and maximum voluntary bite force following segmental resection of the mandible without or with reconstruction.

    PubMed

    Linsen, Sabine S; Oikonomou, Annina; Martini, Markus; Teschke, Marcus

    2018-05-01

    The purpose was to analyze mandibular kinematics and maximum voluntary bite force in patients following segmental resection of the mandible without and with reconstruction (autologous bone, alloplastic total temporomandibular joint replacement (TMJ TJR)). Subjects operated from April 2002 to August 2014 were enrolled in the study. Condylar (CRoM) and incisal (InRoM) range of motion and deflection during opening, condylar retrusion, incisal lateral excursion, mandibular rotation angle during opening, and maximum voluntary bite force were determined on the non-affected site and compared between groups. Influence of co-factors (defect size, soft tissue deficit, neck dissection, radiotherapy, occlusal contact zones (OCZ), and time) was determined. Twelve non-reconstructed and 26 reconstructed patients (13 autologous, 13 TMJ TJR) were included in the study. InRoM opening and bite force were significantly higher (P ≤ .024), and both condylar and incisal deflection during opening significantly lower (P ≤ .027) in reconstructed patients compared with non-reconstructed. Differences between the autologous and the TMJ TJR group were statistically not significant. Co-factors defect size, soft tissue deficit, and neck dissection had the greatest impact on kinematics and number of OCZs on bite force. Reconstructed patients (both autologous and TMJ TJR) have better overall function than non-reconstructed patients. Reconstruction of segmental mandibular resection has positive effects on mandibular function. TMJ TJR seems to be a suitable technique for the reconstruction of mandibular defects including the TMJ complex.

  6. Magnetoencephalography signals are influenced by skull defects.

    PubMed

    Lau, S; Flemming, L; Haueisen, J

    2014-08-01

    Magnetoencephalography (MEG) signals had previously been hypothesized to have negligible sensitivity to skull defects. The objective is to experimentally investigate the influence of conducting skull defects on MEG and EEG signals. A miniaturized electric dipole was implanted in vivo into rabbit brains. Simultaneous recording using 64-channel EEG and 16-channel MEG was conducted, first above the intact skull and then above a skull defect. Skull defects were filled with agar gels, which had been formulated to have tissue-like homogeneous conductivities. The dipole was moved beneath the skull defects, and measurements were taken at regularly spaced points. The EEG signal amplitude increased 2-10 times, whereas the MEG signal amplitude reduced by as much as 20%. The EEG signal amplitude deviated more when the source was under the edge of the defect, whereas the MEG signal amplitude deviated more when the source was central under the defect. The change in MEG field-map topography (relative difference measure, RDM(∗)=0.15) was geometrically related to the skull defect edge. MEG and EEG signals can be substantially affected by skull defects. MEG source modeling requires realistic volume conductor head models that incorporate skull defects. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Use of an Assistant Surgeon Does not Mitigate the Effect of Lead Surgeon Volume on Outcomes Following Open Repair of Intact Abdominal Aortic Aneurysms.

    PubMed

    Deery, Sarah E; O'Donnell, Thomas F X; Zettervall, Sara L; Darling, Jeremy D; Shean, Katie E; O'Malley, A James; Landon, Bruce E; Schermerhorn, Marc L

    2018-05-01

    While higher lead surgeon volume has been associated with lower mortality following open abdominal aortic aneurysm (AAA) repair, little is known about the impact of using an attending surgeon as assistant surgeon. The aim of this study was to determine whether the presence of an assistant surgeon, particularly a high volume assistant, mitigates the relationship between lead surgeon volume and outcomes. All Medicare beneficiaries who underwent intact, open AAA repair between 2003 and 2008 were evaluated and nested regression models were constructed to evaluate the relationship between surgeon and assistant volume and peri-operative mortality, adjusting for comorbid conditions and hospital volume. In total 28,590 repairs were studied, of which 19,284 (67.5%) were performed by a single surgeon and 9306 (32.5%) included an assistant surgeon. Of cases with an assistant, 12.3% included a high volume assistant surgeon. Lower volume surgeons more frequently used an assistant (lead surgeon Q1 volume: 40%; Q2: 36%; Q3: 34%; Q4: 29%; Q5: 27% [p < .01]). In cases with no assistant, adjusted peri-operative mortality varied monotonically with surgeon volume (Q1: 4.7%; Q2: 4.4%; Q3: 4.1%; Q4: 3.3%; Q5: 3.2%). However, the use of a high or a low volume assistant surgeon, compared with no attending surgeon as assistant, was not associated with lower peri-operative mortality in any lead surgeon volume quintile, even among those operations performed by the lowest volume lead surgeons. Employing an assistant surgeon does not improve outcomes amongst any quintile of volume of the lead surgeon. As surgeons perform fewer open AAA repairs in the modern era, these data imply that even the help of a high volume assistant surgeon may not mitigate the detrimental effect of a lower volume surgeon. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  8. Clinical observation of biomimetic mineralized collagen artificial bone putty for bone reconstruction of calcaneus fracture

    PubMed Central

    Pan, Yong-Xiong; Yang, Guang-Gang; Li, Zhong-Wan; Shi, Zhong-Min; Sun, Zhan-Dong

    2018-01-01

    Abstract This study investigated clinical outcomes of biomimetic mineralized collagen artificial bone putty for bone reconstruction in the treatment of calcaneus fracture. Sixty cases of calcaneal fractures surgically treated with open reduction and internal fixation in our hospital from June 2014–2015 were chosen and randomly divided into two groups, including 30 cases treated with biomimetic mineralized collagen artificial bone putty as treatment group, and 30 cases treated with autogenous ilia as control group. The average follow-up time was 17.2 ± 3.0 months. The results showed that the surgery duration and postoperative drainage volume of treatment group were significantly lower than control group; there were no statistically significant differences in the fracture healing time, American Orthopaedic Foot and Ankle Society scores at 3 and 12 months after surgery, Böhler’s angle, Gissane’s angle and height of calcaneus between the two groups. There were no significant differences in wound complication and reject reaction between the two groups, while significant difference in donor site complication. As a conclusion, the implantation of biomimetic mineralized collagen artificial bone putty in the open reduction of calcaneal fracture resulted in reliable effect and less complications, which is suitable for clinical applications in the treatment of bone defect in calcaneal fractures. PMID:29644087

  9. Spatiotemporal Aeration and Lung Injury Patterns Are Influenced by the First Inflation Strategy at Birth.

    PubMed

    Tingay, David G; Rajapaksa, Anushi; Zonneveld, C Elroy; Black, Don; Perkins, Elizabeth J; Adler, Andy; Grychtol, Bartłomiej; Lavizzari, Anna; Frerichs, Inéz; Zahra, Valerie A; Davis, Peter G

    2016-02-01

    Ineffective aeration during the first inflations at birth creates regional aeration and ventilation defects, initiating injurious pathways. This study aimed to compare a sustained first inflation at birth or dynamic end-expiratory supported recruitment during tidal inflations against ventilation without intentional recruitment on gas exchange, lung mechanics, spatiotemporal regional aeration and tidal ventilation, and regional lung injury in preterm lambs. Lambs (127 ± 2 d gestation), instrumented at birth, were ventilated for 60 minutes from birth with either lung-protective positive pressure ventilation (control) or as per control after either an initial 30 seconds of 40 cm H2O sustained inflation (SI) or an initial stepwise end-expiratory pressure recruitment maneuver during tidal inflations (duration 180 s; open lung ventilation [OLV]). At study completion, molecular markers of lung injury were analyzed. The initial use of an OLV maneuver, but not SI, at birth resulted in improved lung compliance, oxygenation, end-expiratory lung volume, and reduced ventilatory needs compared with control, persisting throughout the study. These changes were due to more uniform inter- and intrasubject gravity-dependent spatiotemporal patterns of aeration (measured using electrical impedance tomography). Spatial distribution of tidal ventilation was more stable after either recruitment maneuver. All strategies caused regional lung injury patterns that mirrored associated regional volume states. Irrespective of strategy, spatiotemporal volume loss was consistently associated with up-regulation of early growth response-1 expression. Our results show that mechanical and molecular consequences of lung aeration at birth are not simply related to rapidity of fluid clearance; they are also related to spatiotemporal pressure-volume interactions within the lung during inflation and deflation.

  10. Current Therapeutic Strategies for Adipose Tissue Defects/Repair Using Engineered Biomaterials and Biomolecule Formulations.

    PubMed

    Mahoney, Christopher M; Imbarlina, Cayla; Yates, Cecelia C; Marra, Kacey G

    2018-01-01

    Tissue engineered scaffolds for adipose restoration/repair has significantly evolved in recent years. Patients requiring soft tissue reconstruction, caused by defects or pathology, require biomaterials that will restore void volume with new functional tissue. The gold standard of autologous fat grafting (AFG) is not a reliable option. This review focuses on the latest therapeutic strategies for the treatment of adipose tissue defects using biomolecule formulations and delivery, and specifically engineered biomaterials. Additionally, the clinical need for reliable off-the-shelf therapies, animal models, and challenges facing current technologies are discussed.

  11. Fetal Endoscopic Surgery for Spina Bifida

    ClinicalTrials.gov

    2017-10-16

    Neural Tube Defects; Spina Bifida, Open; Myelomeningocele; Fetal Disease; Hydrocephalus; Chiari Malformation Type 2; Congenital Abnormality; Surgery; Maternal, Uterus or Pelvic Organs, Affecting Fetus

  12. Hedgehog activity controls opening of the primary mouth

    PubMed Central

    Tabler, Jacqueline M.; Bolger, Trióna G.; Wallingford, John; Liu, Karen J.

    2014-01-01

    To feed or breathe, the oral opening must connect with the gut. The foregut and oral tissues converge at the primary mouth, forming the buccopharyngeal membrane (BPM), a bilayer epithelium. Failure to form the opening between gut and mouth has significant ramifications, and many craniofacial disorders have been associated with defects in this process. Oral perforation is characterized by dissolution of the BPM, but little is known about this process. In humans, failure to form a continuous mouth opening is associated with mutations in Hedgehog (Hh) pathway members; however, the role of Hh in primary mouth development is untested. Here, we show, using Xenopus, that Hh signaling is necessary and sufficient to initiate mouth formation, and that Hh activation is required in a dose-dependent fashion to determine the size of the mouth. This activity lies upstream of the previously demonstrated role for Wnt signal inhibition in oral perforation. We then turn to mouse mutants to establish that SHH and Gli3 are indeed necessary for mammalian mouth development. Our data suggest that Hh-mediated BPM persistence may underlie oral defects in human craniofacial syndromes. PMID:25300580

  13. Anterior vaginal introitoplasty for an acquired sensation of wide vagina: a case report and new surgical intervention.

    PubMed

    Ostrzenski, Adam

    2014-01-01

    A vaginal introital defect case and its symptomatology have never been published before. The objective of this presentation was to describe symptoms associated with an acquired sensation of wide vagina and to present a new surgical treatment for anterior vaginal introital defects. A 42-year-old, Caucasian woman, G4P4013, presented with a sensation of wide vagina at the vaginal opening and a history of colpoperineoplasty, without mesh, for the same condition 4 years prior. Clinical evaluation documented anterior vaginal introital defects and the absence of vaginal site-specific defects. Reconstruction of a vaginal introital defect was completed without complications. Surgical resolution of symptoms and signs of this condition were noted. Anterior vaginal introitoplasty can assist in the management of an acquired sensation of wide vagina.

  14. Naval Medical Research and Development News. Volume 8, Issue 6

    DTIC Science & Technology

    2016-06-01

    infection during pregnancy can cause a serious birth defect called microcephaly and other severe fetal brain defects, the CDC says. In May 2015, the... survey with a focus on a variety of topics, including physical and mental health, the quality of marital and family relationships, work/ family...mechanisms. The study is longitudinal and seeks to follow spouses for 21 or more years, with follow-up surveys requested approximately every

  15. Reconstruction of maxillectomy and midfacial defects with free tissue transfer.

    PubMed

    Santamaria, Eric; Cordeiro, Peter G

    2006-11-01

    The maxillary bones are part of the midfacial skeleton and are closely related to the eyeglobe, nasal airway, and oral cavity. Together with the overlying soft tissues, the two maxillae are responsible to a large extent for facial contour. Maxillectomy defects become more complex when critical structures such as the orbit, globe, and cranial base are resected, and reconstruction with distant tissues become essential. In this article, we describe a classification system and algorithm for reconstruction of these complex defects using various pedicled and free flaps. Most defects that involve resection of the maxilla and adjacent soft tissues may be classified into one of the following four types: Type I defects, Limited maxillectomy; Type II defects, Subtotal maxillectomy; Type III defects, Total maxillectomy; and Type IV defects, Orbitomaxillectomy. Using this classification, reconstruction of maxillectomy and midfacial defects may be approached considering the relationship between volume and surface area requirements, that is, addressing the bony defect first, followed by assessment of the associated soft tissue, skin, palate, and cheek-lining deficits. In our experience, most complex maxillectomy defects are best reconstructed using free tissue transfer. The rectus abdominis and radial forearm free flap in combination with immediate bone grafting or as an osteocutaneous flap reliably provide the best aesthetic and functional results. A temporalis muscle pedicled flap is used for reconstruction of maxillectomy defects only in those patients who are not candidates for a microsurgical procedure.

  16. Soft tissue volume augmentation by the use of collagen-based matrices: a volumetric analysis.

    PubMed

    Thoma, Daniel S; Jung, Ronald E; Schneider, David; Cochran, David L; Ender, Andreas; Jones, Archie A; Görlach, Christoph; Uebersax, Lorenz; Graf-Hausner, Ursula; Hämmerle, Christoph H F

    2010-07-01

    The aim was to test whether or not soft tissue augmentation with a newly developed collagen matrix (CM) leads to volume gain in chronic ridge defects similar to those obtained by an autogenous subepithelial connective tissue graft (SCTG). In six dogs, soft tissue volume augmentation was performed by randomly allocating three treatment modalities to chronic ridge defects (CM, SCTG, sham-operated control). Impressions were taken before augmentation (baseline), at 28, and 84 days. The obtained casts were optically scanned and the images were digitally analysed. A defined region of interest was measured in all sites and the volume differences between the time points were calculated. The mean volume differences per area between baseline and 28 days amounted to a gain of 1.6 mm (CM; SD+/-0.9), 1.5 mm (SCTG; +/-0.1), and a loss of 0.003 mm (control; +/-0.3). At 84 days, the mean volume differences per area to baseline measured a gain of 1.4 mm (CM; +/-1.1), 1.4 mm (SCTG; +/-0.4), and a loss of 0.3 mm (control; +/-0.3). The differences between CM and SCTG were statistically significant compared with control at 28 and 84 days (p<0.001). Within the limits of this animal study, the CM may serve as a replacement for autogenous connective tissue.

  17. Investigation of a pre-clinical mandibular bone notch defect model in miniature pigs: clinical computed tomography, micro-computed tomography, and histological evaluation.

    PubMed

    Carlisle, Patricia L; Guda, Teja; Silliman, David T; Lien, Wen; Hale, Robert G; Brown Baer, Pamela R

    2016-02-01

    To validate a critical-size mandibular bone defect model in miniature pigs. Bilateral notch defects were produced in the mandible of dentally mature miniature pigs. The right mandibular defect remained untreated while the left defect received an autograft. Bone healing was evaluated by computed tomography (CT) at 4 and 16 weeks, and by micro-CT and non-decalcified histology at 16 weeks. In both the untreated and autograft treated groups, mineralized tissue volume was reduced significantly at 4 weeks post-surgery, but was comparable to the pre-surgery levels after 16 weeks. After 16 weeks, CT analysis indicated that significantly greater bone was regenerated in the autograft treated defect than in the untreated defect (P=0.013). Regardless of the treatment, the cortical bone was superior to the defect remodeled over 16 weeks to compensate for the notch defect. The presence of considerable bone healing in both treated and untreated groups suggests that this model is inadequate as a critical-size defect. Despite healing and adaptation, the original bone geometry and quality of the pre-injured mandible was not obtained. On the other hand, this model is justified for evaluating accelerated healing and mitigating the bone remodeling response, which are both important considerations for dental implant restorations.

  18. Does surgeon volume matter in the outcome of endoscopic inguinal hernia repair?

    PubMed

    Köckerling, F; Bittner, R; Kraft, B; Hukauf, M; Kuthe, A; Schug-Pass, C

    2017-02-01

    For open and endoscopic inguinal hernia surgery, it has been demonstrated that low-volume surgeons with fewer than 25 and 30 procedures, respectively, per year are associated with significantly more recurrences than high-volume surgeons with 25 and 30 or more procedures, respectively, per year. This paper now explores the relationship between the caseload and the outcome based on the data from the Herniamed Registry. The prospective data of patients in the Herniamed Registry were analyzed using the inclusion criteria minimum age of 16 years, male patient, primary unilateral inguinal hernia, TEP or TAPP techniques and availability of data on 1-year follow-up. In total, 16,290 patients were enrolled between September 1, 2009, and February 1, 2014. Of the participating surgeons, 466 (87.6 %) had carried out fewer than 25 endoscopic/laparoscopic operations (low-volume surgeons) and 66 (12.4 %) surgeons 25 or more operations (high-volume surgeons) per year. Univariable (1.03 vs. 0.73 %; p = 0.047) and multivariable analysis [OR 1.494 (1.065-2.115); p = 0.023] revealed that low-volume surgeons had a significantly higher recurrence rate compared with the high-volume surgeons, although that difference was small. Multivariable analysis also showed that pain on exertion was negatively affected by a lower caseload <25 [OR 1.191 (1.062-1.337); p = 0.003]. While here, too, the difference was small, the fact that in that group there was a greater proportion of patients with small hernia defect sizes may have also played a role since the risk in that group was higher. In this analysis, no evidence was found that pain at rest [OR 1.052 (0.903-1.226); p = 0.516] or chronic pain requiring treatment [OR 1.108 (0.903-1.361); p = 0.326] were influenced by the surgeon volume. As confirmed by previously published studies, the data in the Herniamed Registry also demonstrated that the endoscopic/laparoscopic inguinal hernia surgery caseload impacted the outcome. However, given the overall high-quality level the differences between a "low-volume" surgeon and a "high-volume" surgeon were small. That was due to the use of a standardized technique, structured training as well as continuous supervision of trainees and surgeons with low annual caseload.

  19. Transcatheter closure of a small atrial septal defect with an Amplatzer™ patent foramen ovale occluder in a working dog with cyanosis and exercise intolerance at high altitude.

    PubMed

    Shelden, A; Wesselowski, S; Gordon, S G; Saunders, A B

    2017-12-01

    A 6.5-year-old male Border Collie presented for transcatheter closure of an atrial septal defect due to exercise intolerance and cyanosis while working and training at altitude. A small, left-to-right shunting secundum atrial septal defect was confirmed with no evidence of significant right-sided volume overload. Pulmonary hypertension with subsequent right-to-left interatrial shunting occurring during exercise at high altitude was suspected and prompted the closure of the defect due to the dog's continued athletic requirements. The anatomy of the defect prompted use of a patent foramen ovale occluder rather than an atrial septal defect occluder, which was deployed using a combination of fluoroscopic and transesophageal echocardiographic guidance. The owner did not report continued exercise intolerance or cyanosis and the dog's lifestyle and residence at altitude was unchanged. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Origins and consequences of congenital heart defects affecting the right ventricle.

    PubMed

    Woudstra, Odilia I; Ahuja, Suchit; Bokma, Jouke P; Bouma, Berto J; Mulder, Barbara J M; Christoffels, Vincent M

    2017-10-01

    Congenital heart disease is a major health issue, accounting for a third of all congenital defects. Improved early surgical management has led to a growing population of adults with congenital heart disease, including patients with defects affecting the right ventricle, which are often classified as severe. Defects affecting the right ventricle often cause right ventricular volume or pressure overload and affected patients are at high risk for complications such as heart failure and sudden death. Recent insights into the developmental mechanisms and distinct developmental origins of the left ventricle, right ventricle, and the outflow tract have shed light on the common features and distinct problems arising in specific defects. Here, we provide a comprehensive overview of the current knowledge on the development into the normal and congenitally malformed right heart and the clinical consequences of several congenital heart defects affecting the right ventricle. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  1. ASTRONAUTICS INFORMATION OPEN LITERATURE SURVEY. VOLUME II. NO. 10 (Entries 22,871-23,094)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    1960-10-01

    An open literature survey on astronautics is presented which covers the period of Oct. 1960. The material is organized alphabetically according to subject. A list of periodicals scanned is given in volume II No. 1-2 with addendums in subsequent volumes. Cumulative author and subject indexes are given at the end of the entries. (About 220 references.) (J.R.D.)

  2. Nitrogen doping and CO2 adsorption on graphene: A thermodynamical study

    NASA Astrophysics Data System (ADS)

    Re Fiorentin, Michele; Gaspari, Roberto; Quaglio, Marzia; Massaglia, Gulia; Saracco, Guido

    2018-04-01

    Nitrogen-doped graphene has raised considerable interest for its possible applications as carbon dioxide adsorber and catalyst. In this paper, we provide a theoretical study of graphitic, pyridiniclike and pyrroliclike nitrogen defects in a free-standing graphene layer, focusing on their formation and adsorption behavior. Using density functional theory and thermodynamics, we analyze the various defects, highlighting the great stability of graphitic nitrogen in a wide temperature and pressure range. CO2 adsorption proves to be moderately thermodynamically disfavored around standard conditions for the most stable nitrogen defects and slightly favored for the more energetic ones. The combination of the results on defect stability and CO2 adsorption may open interesting possibilities in the design of carbon-based materials with promising adsorption performances.

  3. Cor triatriatum dexter and atrial septal defect in a 43-year-old woman.

    PubMed

    Vukovic, Petar M; Kosevic, Dragana; Milicic, Miroslav; Jovovic, Ljiljana; Stojanovic, Ivan; Micovic, Slobodan

    2014-08-01

    Cor triatriatum dexter is a rare congenital heart anomaly in which a membrane divides the right atrium into 2 chambers. We report the case of a 43-year-old woman who had cor triatriatum dexter and a large atrial septal defect. During attempted percutaneous closure, the balloon disrupted the membrane and revealed that the defect had no inferior rim, precluding secure placement of an Amplatzer Septal Occluder. Surgical treatment subsequently proved to be successful. In patients with an incomplete membrane and a septal defect with well-defined rims, percutaneous treatment can be the first choice. In patients who have cor triatriatum dexter and unfavorable anatomic features or concomitant complex heart anomalies, open-heart surgery remains the gold standard for treatment.

  4. Cor Triatriatum Dexter and Atrial Septal Defect in a 43-Year-Old Woman

    PubMed Central

    Kosevic, Dragana; Milicic, Miroslav; Jovovic, Ljiljana; Stojanovic, Ivan; Micovic, Slobodan

    2014-01-01

    Cor triatriatum dexter is a rare congenital heart anomaly in which a membrane divides the right atrium into 2 chambers. We report the case of a 43-year-old woman who had cor triatriatum dexter and a large atrial septal defect. During attempted percutaneous closure, the balloon disrupted the membrane and revealed that the defect had no inferior rim, precluding secure placement of an Amplatzer Septal Occluder. Surgical treatment subsequently proved to be successful. In patients with an incomplete membrane and a septal defect with well-defined rims, percutaneous treatment can be the first choice. In patients who have cor triatriatum dexter and unfavorable anatomic features or concomitant complex heart anomalies, open-heart surgery remains the gold standard for treatment. PMID:25120397

  5. Defining the Role of Free Flaps in Partial Breast Reconstruction.

    PubMed

    Smith, Mark L; Molina, Bianca J; Dayan, Erez; Jablonka, Eric M; Okwali, Michelle; Kim, Julie N; Dayan, Joseph H

    2018-03-01

     Free flaps have a well-established role in breast reconstruction after mastectomy; however, their role in partial breast reconstruction remains poorly defined. We reviewed our experience with partial breast reconstruction to better understand indications for free tissue transfer.  A retrospective review was performed of all patients undergoing partial breast reconstruction at our center between February 2009 and October 2015. We evaluated the characteristics of patients who underwent volume displacement procedures versus volume replacement procedures and free versus pedicled flap reconstruction.  There were 78 partial breast reconstructions, with 52 reductions/tissue rearrangements (displacement group) and 26 flaps (replacement group). Bra cup size and body mass index (BMI) were significantly smaller in the replacement group. Fifteen pedicled and 11 free flaps were performed. Most pedicled flaps (80.0%) were used for lateral or upper pole defects. Most free flaps (72.7%) were used for medial and inferior defects or when there was inadequate donor tissue for a pedicled flap. Complications included hematoma, cellulitis, and one aborted pedicled flap.  Free and pedicled flaps are useful for partial breast reconstruction, particularly in breast cancer patients with small breasts undergoing breast-conserving treatment (BCT). Flap selection depends on defect size, location, and donor tissue availability. Medial defects are difficult to reconstruct using pedicled flaps due to arc of rotation and intervening breast tissue. Free tissue transfer can overcome these obstacles. Confirming negative margins before flap reconstruction ensures harvest of adequate volume and avoids later re-operation. Judicious use of free flaps for oncoplastic reconstruction expands the possibility for breast conservation. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  6. Investigation of oxygen self-diffusion in PuO 2 by combining molecular dynamics with thermodynamic calculations

    DOE PAGES

    Saltas, V.; Chroneos, A.; Cooper, Michael William D.; ...

    2016-01-01

    In the present work, the defect properties of oxygen self-diffusion in PuO 2 are investigated over a wide temperature (300–1900 K) and pressure (0–10 GPa) range, by combining molecular dynamics simulations and thermodynamic calculations. Based on the well-established cBΩ thermodynamic model which connects the activation Gibbs free energy of diffusion with the bulk elastic and expansion properties, various point defect parameters such as activation enthalpy, activation entropy, and activation volume were calculated as a function of T and P. Molecular dynamics calculations provided the necessary bulk properties for the proper implementation of the thermodynamic model, in the lack of anymore » relevant experimental data. The estimated compressibility and the thermal expansion coefficient of activation volume are found to be more than one order of magnitude greater than the corresponding values of the bulk plutonia. As a result, the diffusion mechanism is discussed in the context of the temperature and pressure dependence of the activation volume.« less

  7. Band Structure Characteristics of Nacreous Composite Materials with Various Defects

    NASA Astrophysics Data System (ADS)

    Yin, J.; Zhang, S.; Zhang, H. W.; Chen, B. S.

    2016-06-01

    Nacreous composite materials have excellent mechanical properties, such as high strength, high toughness, and wide phononic band gap. In order to research band structure characteristics of nacreous composite materials with various defects, supercell models with the Brick-and-Mortar microstructure are considered. An efficient multi-level substructure algorithm is employed to discuss the band structure. Furthermore, two common systems with point and line defects and varied material parameters are discussed. In addition, band structures concerning straight and deflected crack defects are calculated by changing the shear modulus of the mortar. Finally, the sensitivity of band structures to the random material distribution is presented by considering different volume ratios of the brick. The results reveal that the first band gap of a nacreous composite material is insensitive to defects under certain conditions. It will be of great value to the design and synthesis of new nacreous composite materials for better dynamic properties.

  8. Ultrasonic sensing of GMAW: Laser/EMAT defect detection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, N.M.; Johnson, J.A.; Larsen, E.D.

    1992-08-01

    In-process ultrasonic sensing of welding allows detection of weld defects in real time. A noncontacting ultrasonic system is being developed to operate in a production environment. The principal components are a pulsed laser for ultrasound generation and an electromagnetic acoustic transducer (EMAT) for ultrasound reception. A PC-based data acquisition system determines the quality of the weld on a pass-by-pass basis. The laser/EMAT system interrogates the area in the weld volume where defects are most likely to occur. This area of interest is identified by computer calculations on a pass-by-pass basis using weld planning information provided by the off-line programmer. Themore » absence of a signal above the threshold level in the computer-calculated time interval indicates a disruption of the sound path by a defect. The ultrasonic sensor system then provides an input signal to the weld controller about the defect condition. 8 refs.« less

  9. Radiation-acoustic treatment of gallium phosphide light diodes

    NASA Astrophysics Data System (ADS)

    Tartachnik, Volodimir P.; Gontaruk, Olexsandr M.; Vernydub, Roman M.; Kryvutenko, Anatoly M.; Olikh, Yaroslav M.; Opilat, Vitalij Y.; Petrenko, Igor V.; Pinkovska, Myroslava B.

    1999-11-01

    The ultrasound influence on the defects of technological and radiation origin of GaP light diodes has been investigated. GaP light diodes were treated by ultrasound wave in different operating modes. Electroluminescence spectra were measured at room and low temperatures, integrated luminosity of devices was checked by solar cell. In order to find out the radiation field influence on non-equilibrium defects of acoustic origin samples were irradiated at room temperature by gamma rays of Co60. It has been discovered that in GaP light diodes treated by ultrasound unstable at room temperature dislocation networks occur at the volume of crystal. Ultrasound dose increase causes the creation of complex defects with high relaxation time and appearing of a part of more mobile defect,s which relax quicker. The nature of effects discovered has been discussed. The method of the emissive capacity restoring of samples degraded after irradiation have been proposed.

  10. Changing of optical absorption and scattering coefficients in nonlinear-optical crystal lithium triborate before and after interaction with UV-radiation

    NASA Astrophysics Data System (ADS)

    Demkin, Artem S.; Nikitin, Dmitriy G.; Ryabushkin, Oleg A.

    2016-04-01

    In current work optical properties of LiB3O5 (LBO) crystal with ultraviolet (UV) (λ= 266 nm) induced volume macroscopic defect (track) are investigated using novel piezoelectric resonance laser calorimetry technique. Pulsed laser radiation of 10 W average power at 532 nm wavelength, is consecutively focused into spatial regions with and without optical defect. For these cases exponential fitting of crystal temperature kinetics measured during its irradiation gives different optical absorption coefficients α1 = 8.1 • 10-4 cm-1 (region with defect) and α =3.9ṡ10-4 cm-1 (non-defected region). Optical scattering coefficient is determined as the difference between optical absorption coefficients measured for opaque and transparent lateral facets of the crystal respectively. Measurements reveal that scattering coefficient of LBO in the region with defect is three times higher than the optical absorption coefficient.

  11. Understanding and Calibrating Density-Functional-Theory Calculations Describing the Energy and Spectroscopy of Defect Sites in Hexagonal Boron Nitride.

    PubMed

    Reimers, Jeffrey R; Sajid, A; Kobayashi, Rika; Ford, Michael J

    2018-03-13

    Defect states in 2-D materials present many possible uses but both experimental and computational characterization of their spectroscopic properties is difficult. We provide and compare results from 13 DFT and ab initio computational methods for up to 25 excited states of a paradigm system, the V N C B defect in hexagonal boron nitride (h-BN). Studied include: (i) potentially catastrophic effects for computational methods arising from the multireference nature of the closed-shell and open-shell states of the defect, which intrinsically involves broken chemical bonds, (ii) differing results from DFT and time-dependent DFT (TDDFT) calculations, (iii) comparison of cluster models to periodic-slab models of the defect, (iv) the starkly differing effects of nuclear relaxation on the various electronic states that control the widths of photoabsorption and photoemission spectra as broken bonds try to heal, (v) the effect of zero-point energy and entropy on free-energy differences, (vi) defect-localized and conduction/valence-band transition natures, and (vii) strategies needed to ensure that the lowest-energy state of a defect can be computationally identified. Averaged state-energy differences of 0.3 eV are found between CCSD(T) and MRCI energies, with thermal effects on free energies sometimes also being of this order. However, DFT-based methods can perform very poorly. Simple generalized-gradient functionals like PBE fail at the most basic level and should never be applied to defect states. Hybrid functionals like HSE06 work very well for excitations within the triplet manifold of the defect, with an accuracy equivalent to or perhaps exceeding the accuracy of the ab initio methods used. However, HSE06 underestimates triplet-state energies by on average of 0.7 eV compared to closed-shell singlet states, while open-shell singlet states are predicted to be too low in energy by 1.0 eV. This leads to misassignment of the ground state of the V N C B defect. Long-range corrected functionals like CAM-B3LYP are shown to work much better and to represent the current entry level for DFT calculations on defects. As significant differences between cluster and periodic-slab models are also found, the widespread implementation of such functionals in periodic codes is in urgent need.

  12. Exercises in anatomy: holes between the ventricles.

    PubMed

    Anderson, Robert H; Sarwark, Anne E; Spicer, Diane E; Backer, Carl L

    2014-01-01

    Holes between the ventricles are the commonest congenital cardiac malformations. As yet, however, there is no consensus as to how they can best be described and categorized. In this, our third exercise in cardiac anatomy, we address the issue of classification of ventricular septal defects. We begin our demonstration by analysing the normal heart. We show that the larger part of the ventricular septum is made up of its muscular component. The membranous part accounts for only a small portion, which is located centrally within the cardiac base. This small membranous part forms a boundary between the right-sided chambers and the aortic root. Holes at this site, therefore, which account for the commonest defects closed surgically, will open centrally in the cardiac base, being located postero-inferiorly relative to the supraventricular crest. We then show that the larger part of the crest itself is a free-standing muscular sleeve, which lifts the leaflets of the pulmonary valve away from the cardiac base. Only a very small part of the muscle forming the right ventricular outlet is located in the septal position. Turning our attention to malformed hearts, we show how holes between the ventricles can open centrally at the cardiac base, open to the inlet or outlet of the right ventricle or open within the substance of the apical muscular septum. We demonstrate, however, that description of such geographical location of the defects does not paint the full picture, since lesions with markedly different phenotypic features can open in comparable geographic locations. We illustrate how it is the phenotypic features, as seen from the right ventricle, which convey the crucial information for the surgeon with regard to the location of the atrioventricular conduction axis, using hearts with holes opening to the inlet of the right ventricle with muscular as opposed to partially fibrous borders to emphasize this point. We continue by showing how holes with different phenotypes can also open to the outlet of the right ventricle, the key feature in this regard being malalignment between the apical muscular septum relative to the muscular outlet septum or its fibrous remnant. Malalignment can also be found between the apical ventricular septum and the atrial septum, this being shown in a defect opening to the inlet of the right ventricle. We conclude by emphasizing that, so as to bring together all the information of surgical significance, it is necessary to take note of the geographical location of holes between the ventricles, their phenotypic features and the presence or absence of malalignment between the septal components. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Using process monitor wafers to understand directed self-assembly defects

    NASA Astrophysics Data System (ADS)

    Cao, Yi; Her, YoungJun; Delgadillo, Paulina R.; Vandenbroeck, Nadia; Gronheid, Roel; Chan, Boon Teik; Hashimoto, Yukio; Romo, Ainhoa; Somervell, Mark; Nafus, Kathleen; Nealey, Paul F.

    2013-03-01

    As directed self-assembly (DSA) has gained momentum over the past few years, questions about its application to high volume manufacturing have arisen. One of the major concerns is about the fundamental limits of defectivity that can be attained with the technology. If DSA applications demonstrate defectivity that rivals of traditional lithographic technologies, the pathway to the cost benefits of the technology creates a very compelling case for its large scale implementation. To address this critical question, our team at IMEC has established a process monitor flow to track the defectivity behaviors of an exemplary chemo-epitaxy application for printing line/space patterns. Through establishing this baseline, we have been able to understand both traditional lithographic defect sources in new materials as well as new classes of assembly defects associated with DSA technology. Moreover, we have explored new materials and processing to lower the level of the defectivity baseline. The robustness of the material sets and process is investigated as well. In this paper, we will report the understandings learned from the IMEC DSA process monitor flow.

  14. Lung Function before and Two Days after Open-Heart Surgery.

    PubMed

    Urell, Charlotte; Westerdahl, Elisabeth; Hedenström, Hans; Janson, Christer; Emtner, Margareta

    2012-01-01

    Reduced lung volumes and atelectasis are common after open-heart surgery, and pronounced restrictive lung volume impairment has been found. The aim of this study was to investigate factors influencing lung volumes on the second postoperative day. Open-heart surgery patients (n = 107, 68 yrs, 80% male) performed spirometry both before surgery and on the second postoperative day. The factors influencing postoperative lung volumes and decrease in lung volumes were investigated with univariate and multivariate analyses. Associations between pain (measured by numeric rating scale) and decrease in postoperative lung volumes were calculated with Spearman rank correlation test. Lung volumes decreased by 50% and were less than 40% of the predictive values postoperatively. Patients with BMI >25 had lower postoperative inspiratory capacity (IC) (33 ± 14% pred.) than normal-weight patients (39 ± 15% pred.), (P = 0.04). More pain during mobilisation was associated with higher decreases in postoperative lung volumes (VC: r = 0.33, P = 0.001; FEV(1): r = 0.35, P ≤ 0.0001; IC: r = 0.25, P = 0.01). Patients with high BMI are a risk group for decreased postoperative lung volumes and should therefore receive extra attention during postoperative care. As pain is related to a larger decrease in postoperative lung volumes, optimal pain relief for the patients should be identified.

  15. Lung Function before and Two Days after Open-Heart Surgery

    PubMed Central

    Urell, Charlotte; Westerdahl, Elisabeth; Hedenström, Hans; Janson, Christer; Emtner, Margareta

    2012-01-01

    Reduced lung volumes and atelectasis are common after open-heart surgery, and pronounced restrictive lung volume impairment has been found. The aim of this study was to investigate factors influencing lung volumes on the second postoperative day. Open-heart surgery patients (n = 107, 68 yrs, 80% male) performed spirometry both before surgery and on the second postoperative day. The factors influencing postoperative lung volumes and decrease in lung volumes were investigated with univariate and multivariate analyses. Associations between pain (measured by numeric rating scale) and decrease in postoperative lung volumes were calculated with Spearman rank correlation test. Lung volumes decreased by 50% and were less than 40% of the predictive values postoperatively. Patients with BMI >25 had lower postoperative inspiratory capacity (IC) (33 ± 14% pred.) than normal-weight patients (39 ± 15% pred.), (P = 0.04). More pain during mobilisation was associated with higher decreases in postoperative lung volumes (VC: r = 0.33, P = 0.001; FEV1: r = 0.35, P ≤ 0.0001; IC: r = 0.25, P = 0.01). Patients with high BMI are a risk group for decreased postoperative lung volumes and should therefore receive extra attention during postoperative care. As pain is related to a larger decrease in postoperative lung volumes, optimal pain relief for the patients should be identified. PMID:22924127

  16. Correlation of 68Ga Ventilation-Perfusion PET/CT with Pulmonary Function Test Indices for Assessing Lung Function.

    PubMed

    Le Roux, Pierre-Yves; Siva, Shankar; Steinfort, Daniel P; Callahan, Jason; Eu, Peter; Irving, Lou B; Hicks, Rodney J; Hofman, Michael S

    2015-11-01

    Pulmonary function tests (PFTs) are routinely used to assess lung function, but they do not provide information about regional pulmonary dysfunction. We aimed to assess correlation of quantitative ventilation-perfusion (V/Q) PET/CT with PFT indices. Thirty patients underwent V/Q PET/CT and PFT. Respiration-gated images were acquired after inhalation of (68)Ga-carbon nanoparticles and administration of (68)Ga-macroaggregated albumin. Functional volumes were calculated by dividing the volume of normal ventilated and perfused (%NVQ), unmatched and matched defects by the total lung volume. These functional volumes were correlated with forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), FEV1/FVC, and diffusing capacity for carbon monoxide (DLCO). All functional volumes were significantly different in patients with chronic obstructive pulmonary disease (P < 0.05). FEV1/FVC and %NVQ had the highest correlation (r = 0.82). FEV1 was also best correlated with %NVQ (r = 0.64). DLCO was best correlated with the volume of unmatched defects (r = -0.55). Considering %NVQ only, a cutoff value of 90% correctly categorized 28 of 30 patients with or without significant pulmonary function impairment. Our study demonstrates strong correlations between V/Q PET/CT functional volumes and PFT parameters. Because V/Q PET/CT is able to assess regional lung function, these data support the feasibility of its use in radiation therapy and preoperative planning and assessing pulmonary dysfunction in a variety of respiratory diseases. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  17. Design and Simulation of Microstrip Hairpin Bandpass Filter with Open Stub and Defected Ground Structure (DGS) at X-Band Frequency

    NASA Astrophysics Data System (ADS)

    Hariyadi, T.; Mulyasari, S.; Mukhidin

    2018-02-01

    In this paper we have designed and simulated a Band Pass Filter (BPF) at X-band frequency. This filter is designed for X-band weather radar application with 9500 MHz center frequency and bandwidth -3 dB is 120 MHz. The filter design was performed using a hairpin microstrip combined with an open stub and defected ground structure (DGS). The substrate used is Rogers RT5880 with a dielectric constant of 2.2 and a thickness of 1.575 mm. Based on the simulation results, it is found that the filter works on frequency 9,44 - 9,56 GHz with insertion loss value at pass band is -1,57 dB.

  18. Status of the internal orbit after reduction of zygomaticomaxillary complex fractures.

    PubMed

    Ellis, Edward; Reddy, Likith

    2004-03-01

    We sought to determine the status of the internal orbit before and after reduction of zygomaticomaxillary complex (ZMC) fractures when treated without internal orbital reconstruction. We conducted a retrospective study of preoperative and postoperative computed tomography (CT) scans in 65 patients with unilateral ZMC fractures who were treated by reduction of the ZMC complex without internal orbital reconstruction. The size and location of the internal orbital defects, orbital soft tissue displacement, and orbital volume were assessed in the preoperative and postoperative CT scans. Reduction in the ZMC fractures was considered ideal in 58 of the 65 patients. Only minor malpositions occurred in the remaining 7 patients. The size of the internal orbital defects increased slightly with ZMC reduction but the internal orbital fractures were realigned, and few had increases in orbital volume or soft tissue sagging into the sinuses. Examination of follow-up CT scans in several patients taken weeks to months later showed that the residual defects became smaller and that none of these patients had an increase in orbital volume or soft tissue sagging. The preoperative CT scan can be used to assess the amount of internal orbital disruption for purposes of developing a treatment plan in patients with ZMC fractures. When there is minimal or no soft tissue herniation and minimal disruption of the internal orbit, ZMC reduction is adequate treatment.

  19. The physiological basis and clinical significance of lung volume measurements.

    PubMed

    Lutfi, Mohamed Faisal

    2017-01-01

    From a physiological standpoint, the lung volumes are either dynamic or static. Both subclasses are measured at different degrees of inspiration or expiration; however, dynamic lung volumes are characteristically dependent on the rate of air flow. The static lung volumes/capacities are further subdivided into four standard volumes (tidal, inspiratory reserve, expiratory reserve, and residual volumes) and four standard capacities (inspiratory, functional residual, vital and total lung capacities). The dynamic lung volumes are mostly derived from vital capacity. While dynamic lung volumes are essential for diagnosis and follow up of obstructive lung diseases, static lung volumes are equally important for evaluation of obstructive as well as restrictive ventilatory defects. This review intends to update the reader with the physiological basis, clinical significance and interpretative approaches of the standard static lung volumes and capacities.

  20. [A comparison between prostatic volume measured during suprapubic ultrasonography (TAUS) and volume of the enucleated gland after open prostatectomy].

    PubMed

    Szewczyk, Wojciech; Prajsner, Andrzej; Kozina, Janusz; Login, Tomasz; Kaczorowski, Marek

    2004-01-01

    General practitioner very often uses transabdominal ultrasonograpy (TAUS) in order to measure prostatic volume. Using this method it is rather impossible to distinguish between tissue of benign prostatic hyperplasia (BPH) and prostatic tissue which forms so called surgical capsule of BPH. The aim of this study was a comparison of prostatic volume measured during suprapubic (transabdominal) ultrasonography and volume of the enucleated gland after open prostatectomy. Regarding the results authors created a nomogram based on TAUS measurement of the prostate which helps to predict the volume of BPH. They also stated that surgical capsule of the BPH makes about 1/3 of the whole volume of the prostate measured by TAUS.

  1. Localized Defect Modes in a Two-Dimensional Array of Magnetic Nanodots

    DTIC Science & Technology

    2013-06-22

    number of defects it is possible to obtain the information about the entire spin-wave spectrum of the array. Index Terms—Spin waves, magnonic crystal...multistability opens a way for the development of a novel type of artificial materials with tunable microwave properties – reconfigurable magnonic ...information about the entire spin-wave spectrum of the array. 15. SUBJECT TERMS Spin waves, magnonic crystal, magnetic dot, ferromagnetic resonance

  2. Association of the missense variant p.Arg203Trp in PACS1 as a cause of intellectual disability and seizures.

    PubMed

    Stern, D; Cho, M T; Chikarmane, R; Willaert, R; Retterer, K; Kendall, F; Deardorff, M; Hopkins, S; Bedoukian, E; Slavotinek, A; Schrier Vergano, S; Spangler, B; McDonald, M; McConkie-Rosell, A; Burton, B K; Kim, K H; Oundjian, N; Kronn, D; Chandy, N; Baskin, B; Guillen Sacoto, M J; Wentzensen, I M; McLaughlin, H M; McKnight, D; Chung, W K

    2017-08-01

    Graphical abstract key: ADHD, attention deficit hyperactivity disorder; ASD, atrial septal defect; DD, developmental delay; EEG, electroencephalogram; Ht, height; ID, intellectual disability; OCD, obsessive-compulsive disorder; OFC, open fontanelle; PDA, patent ductus arteriosis; PFO, patent foramen ovale; VSD, ventricular septal defect; Wt, weight. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Other origins for the fluorescence modulation of single dye molecules in open-circuit and short-circuit devices.

    PubMed

    Teguh, Jefri S; Kurniawan, Michael; Wu, Xiangyang; Sum, Tze Chien; Yeow, Edwin K L

    2013-01-07

    Fluorescence intensity modulation of single Atto647N dye molecules in a short-circuit device and a defective device, caused by damaging an open-circuit device, is due to a variation in the excitation light focus as a result of the formation of an alternating electric current.

  4. 40 CFR 60.113b - Testing and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...), prior to filling the storage vessel with VOL. If there are holes, tears, or other openings in the..., or the seal is detached, or there are holes or tears in the seal fabric, the owner or operator shall... has defects, the primary seal has holes, tears, or other openings in the seal or the seal fabric, or...

  5. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  6. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  7. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  8. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  9. 10 CFR 39.43 - Inspection, maintenance, and opening of a source or source holder.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Inspection, maintenance, and opening of a source or source holder. 39.43 Section 39.43 Energy NUCLEAR REGULATORY COMMISSION LICENSES AND RADIATION SAFETY..., for defects before each use to ensure that the equipment is in good working condition and that...

  10. Walter Reed Army Medical Center, Washington, D. C. Annual Progress Report FY-89. Volume 2. Part 2

    DTIC Science & Technology

    1990-01-02

    Patterns of Cerebral Blood Flow Determined by Iodoamphetamine SPECT in Sjogren’s Syndrome and Systemic Lupus Erythematosus: A Pilot Study KEYWORDS: SPECT...scanning in patients with Sjogren’s Syndrome and SLE. To identify possible regional defects in cerebral blood flow and correlate these defects with the...in animals reveals myelosuppression, lymphoid atrophy, * hemorrhagic enterocolitis, renal tubular necrosis, and cochlear damage, as well as some

  11. Microscopic Investigation of Materials Limitations of Superconducting RF Cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anlage, Steven

    2017-08-04

    Our overall goal is to contribute to the understanding of defects that limit the high accelerating gradient performance of Nb SRF cavities. Our approach is to develop a microscopic connection between materials defects and SRF performance. We developed a near-field microwave microscope to establish this connection. The microscope is based on magnetic hard drive write heads, which are designed to create very strong rf magnetic fields in very small volumes on a surface.

  12. An osteoconductive, osteoinductive, and osteogenic tissue-engineered product for trauma and orthopaedic surgery: how far are we?

    PubMed

    Khan, Wasim S; Rayan, Faizal; Dhinsa, Baljinder S; Marsh, David

    2012-01-01

    The management of large bone defects due to trauma, degenerative disease, congenital deformities, and tumor resection remains a complex issue for the orthopaedic reconstructive surgeons. The requirement is for an ideal bone replacement which is osteoconductive, osteoinductive, and osteogenic. Autologous bone grafts are still considered the gold standard for reconstruction of bone defects, but donor site morbidity and size limitations are major concern. The use of bioartificial bone tissues may help to overcome these problems. The reconstruction of large volume defects remains a challenge despite the success of reconstruction of small-to-moderate-sized bone defects using engineered bone tissues. The aim of this paper is to understand the principles of tissue engineering of bone and its clinical applications in reconstructive surgery.

  13. An Osteoconductive, Osteoinductive, and Osteogenic Tissue-Engineered Product for Trauma and Orthopaedic Surgery: How Far Are We?

    PubMed Central

    Khan, Wasim S.; Rayan, Faizal; Dhinsa, Baljinder S.; Marsh, David

    2012-01-01

    The management of large bone defects due to trauma, degenerative disease, congenital deformities, and tumor resection remains a complex issue for the orthopaedic reconstructive surgeons. The requirement is for an ideal bone replacement which is osteoconductive, osteoinductive, and osteogenic. Autologous bone grafts are still considered the gold standard for reconstruction of bone defects, but donor site morbidity and size limitations are major concern. The use of bioartificial bone tissues may help to overcome these problems. The reconstruction of large volume defects remains a challenge despite the success of reconstruction of small-to-moderate-sized bone defects using engineered bone tissues. The aim of this paper is to understand the principles of tissue engineering of bone and its clinical applications in reconstructive surgery. PMID:25098363

  14. Transcatheter closure of left ventricle to right atrial communication using cera duct occluder.

    PubMed

    Ganesan, Gnanavelu; Paul, G Justin; Mahadevan, Vaikom S

    Left ventricle-right atrial communication could be congenital (Gerbode defect) or acquired as a complication of surgery or infective endocarditis and leads to volume overloading of pulmonary circulation. Two types, direct and indirect types are known depending on the involvement of septal tricuspid leaflet. Transcatheter closure of this defect is feasible and appears an attractive alternative to surgical management. Various devices like Amplatzer duct occluder I, II, Muscular ventricular septal defect device etc. have been used to close this defect. We report two patients, a preteen boy with direct left ventricle-right atrial communication as post operative complication and an adult female with indirect communication who underwent transcatheter closure with Cera duct occluder (Lifetech Scientific (Shenzhen), China). Copyright © 2017. Published by Elsevier B.V.

  15. Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

    NASA Technical Reports Server (NTRS)

    Jeevarajan, J.; Chung, J.-S.; Jung, K.; Park, J.

    2013-01-01

    The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a day); continue for total of 14 days with 1 reading per day 2. Soft Short Test 1: Fully charge; cells discharged to manufacturer's end of disch. Voltage (EODV) cutoff at C/5 rate; stand for 30 minutes; discharge with C/500 to the same EODV. stand for another 30 minutes; discharge the cells again using C/1000 current to the same EODV. OCV measurements twice a day for 72 hours and then for total of 14 days (data collection same as in 1.) 3. Soft Short Test 2: Fully charge; cells discharged to the manuf. EODV with a C/13 constant current; provide a 10 hour rest, discharge again to the same EODV with a current of C/250, provide a 10 hour rest, discharge again using a C/250 rate, provide a 24 hour rest, charge using C/250 to 3.15 V (for 12 hours). OCV measurements twice a day for at 72 hours. (data collection same as in 1.) 4. Soft Short Test 3: Fully charge; cells shall be discharged using C/10 current to manuf. EODV. Allow the cell to remain at Open circuit for 10 seconds. Discharge the cell at C/20 rate to the same EODV, hold open circuit for 24 hours. Discharge the cells at C/200 rate to the same end of voltage cutoff and hold open circuit for 24 hours. Discharge the cells one more time at C/200 rate to the same EODV and hold open circuit for 36 hours. Charge at C/200 rate to 3.15 V and hold for 3 days. Record OCV during the open circuit stand periods every 12 hours and at the beginning and end of the 3 day hold (include the 12 hour OCV recording during this time also). Capacity Cycling: Cells with declining voltages - one cell from each manufacturer chosen for cycling Destructive Physical Analysis (DPA): Cells with and without decline chosen from each lot for DPA.

  16. Free-volume characterization of nanostructurized substances by positron annihilation lifetime spectroscopy

    NASA Astrophysics Data System (ADS)

    Shpotyuk, O.; Ingram, A.; Shpotyuk, Ya.

    2018-02-01

    Methodological possibilities of positron annihilation lifetime (PAL) spectroscopy are examined to parameterize free-volume structural evolution processes in some nanostructurized substances obeying conversion from positronium (Ps) decaying to positron trapping. Unlike conventional x3-term fitting analysis based on admixed positron trapping and Ps decaying, the effect of nanostructurization is considered as occurring due to conversion from preferential Ps decaying in initial host matrix to positron trapping in modified (nanostructurized) host-guest matrix. The developed approach referred to as x3-x2-CDA (coupling decomposition algorithm) allows estimation defect-free bulk and defect-specific positron lifetimes of free-volume elements responsible for nanostructurization. The applicability of this approach is proved for some nanostructurized materials allowing free-volume changes through Ps-to-positron trapping conversion, such as (i) metallic Ag nanoparticles embedded in polymer matrix, (ii) structure-modification processes caused by swift heavy ions irradiation in polystyrene, and (iii) host-guest chemistry problems like water immersion in alumomagnesium spinel ceramics. This approach is considered to be used as test-indicator, separating processes of host-matrix nanostructurization due to embedded nanoparticles from uncorrelated changes in positron-trapping and Ps-decaying channels.

  17. Acoustically driven degradation in single crystalline silicon solar cell

    NASA Astrophysics Data System (ADS)

    Olikh, O. Ya.

    2018-05-01

    The influence of ultrasound on current-voltage characteristics of crystalline silicon solar sell was investigated experimentally. The transverse and longitudinal acoustic waves were used over a temperature range of 290-340 K. It was found that the ultrasound loading leads to the reversible decrease in the photogenerated current, open-circuit voltage, fill factor, carrier lifetime, and shunt resistance as well as the increase in the ideality factor. The experimental results were described by using the models of coupled defect level recombination, Shockley-Read-Hall recombination, and dislocation-induced impedance. The contribution of the boron-oxygen related defects, iron-boron pairs, and oxide precipitates to both the carrier recombination and acousto-defect interaction was discussed. The experimentally observed phenomena are associated with the increase in the distance between coupled defects as well as the extension of the carrier capture coefficient of complex point defects and dislocations.

  18. A Novel Type of Macrothrombocytopenia Associated with a Defect in α2,3-Sialylation

    PubMed Central

    Jones, Claire; Denecke, Jonas; Sträter, Ronald; Stölting, Torsten; Schunicht, Yvonne; Zeuschner, Dagmar; Klumperman, Judith; Lefeber, Dirk J.; Spelten, Oliver; Zarbock, Alexander; Kelm, Sørge; Strenge, Karen; Haslam, Stuart M.; Lühn, Kerstin; Stahl, Dorothea; Gentile, Luca; Schreiter, Thomas; Hilgard, Philip; Beck-Sickinger, Annette G.; Marquardt, Thorsten; Wild, Martin K.

    2011-01-01

    We describe a novel type of human thrombocytopenia characterized by the appearance of giant platelets and variable neutropenia. Searching for the molecular defect, we found that neutrophils had strongly reduced sialyl-Lewis X and increased Lewis X surface expression, pointing to a deficiency in sialylation. We show that the glycosylation defect is restricted to α2,3-sialylation and can be detected in platelets, neutrophils, and monocytes. Platelets exhibited a distorted structure of the open canalicular system, indicating defective platelet generation. Importantly, patient platelets, but not normal platelets, bound to the asialoglycoprotein receptor (ASGP-R), a liver cell-surface protein that removes desialylated thrombocytes from the circulation in mice. Taken together, this is the first type of human thrombocytopenia in which a specific defect of α2,3-sialylation and an induction of platelet binding to the liver ASGP-R could be detected. PMID:21864493

  19. First-principles study of intrinsic defects in formamidinium lead triiodide perovskite solar cell absorbers.

    PubMed

    Liu, Na; Yam, ChiYung

    2018-03-07

    As an alternative to methylammonium lead triiodide (MAPbI 3 ), formamidinium lead triiodide (FAPbI 3 ) perovskites have recently attracted significant attention because of their higher stability and smaller band gaps. Here, based on first-principles calculations, we investigate systematically the intrinsic defects in FAPbI 3 . While methylammonium (MA)-related defects MA I and I MA in MAPbI 3 have high formation energies, we found that formamidinium (FA)-related defects V FA , FA I and I FA in FAPbI 3 have much lower formation energies. Antisites FA I and I FA create deep levels in the band gap, and they can act as recombination centers and result in reduced carrier lifetimes and low open circuit voltages in FAPbI 3 -based photovoltaic devices. We further demonstrate that through cation mixing of MA and FA in perovskites the formation of these defects can be substantially suppressed.

  20. Structural correlates of Openness and Intellect: Implications for the contribution of personality to creativity.

    PubMed

    Vartanian, Oshin; Wertz, Christopher J; Flores, Ranee A; Beatty, Erin L; Smith, Ingrid; Blackler, Kristen; Lam, Quan; Jung, Rex E

    2018-04-15

    Openness/Intellect (i.e., openness to experience) is the Big Five personality factor most consistently associated with individual differences in creativity. Recent psychometric evidence has demonstrated that this factor consists of two distinct aspects-Intellect and Openness. Whereas Intellect reflects perceived intelligence and intellectual engagement, Openness reflects engagement with fantasy, perception, and aesthetics. We investigated the extent to which Openness and Intellect are associated with variations in brain structure as measured by cortical thickness, area, and volume (N = 185). Our results demonstrated that Openness was correlated inversely with cortical thickness and volume in left middle frontal gyrus (BA 6), middle temporal gyrus (MTG, BA 21), and superior temporal gyrus (BA 41), and exclusively with cortical thickness in left inferior parietal lobule (BA 40), right inferior frontal gyrus (IFG, BA 45), and MTG (BA 37). When age and sex were statistically controlled for, the inverse correlations between Openness and cortical thickness remained statistically significant for all regions except left MTG, whereas the correlations involving cortical volume remained statistically significant only for left middle frontal gyrus. There was no statistically significant correlation between Openness and cortical area, and no statistically significant correlation between Intellect and cortical thickness, area, or volume. Our results demonstrate that individual differences in Openness are correlated with variation in brain structure-particularly as indexed by cortical thickness. Given the involvement of the above regions in processes related to memory and cognitive control, we discuss the implications of our findings for the possible contribution of personality to creative cognition. © 2018 Her Majesty the Queen in Right of Canada 2018. Reproduced with permission of the Minister of Health, Canada. Human Brain Mapping.

  1. Single-crystalline oxide films of the Al2O3-Y2O3-R2O3 system as optical sensors of various types of ionizing radiation: significant advantages over volume analogs

    NASA Astrophysics Data System (ADS)

    Zorenko, Yuri V.; Batenchuk, M.; Gorbenco, V.; Pashkovsky, M.

    1997-02-01

    This investigation is dedicated to studying of peculiarities of luminescent properties of the single crystalline films (SCF) of Al2O3-Y2O3-R2O3 oxide system with alpha-Al2O3 and garnet structure, which are used as various types of ionizing radiation luminescent detectors. These peculiarities define the number of nontrivial advantages over their volume analogues. It is shown that SCF are characterized by the low concentrations of vacancy type defects and substituent defects, and the high concentration of Pb ion as dopant. This allows us to substantially increase the spatial resolution and selectivity of cathodoluminophores on the base of these compounds.

  2. The effect of weld metal matching on girth weld performance: Volume III - an ECA analysis. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denys, R.M.; Martin, J.T.

    1995-02-01

    Modern pipeline standards contain alternative methodologies for determining the acceptable defect size in pipeline welds. Through the use of fracture mechanics and plastic collapse assessments, the mechanical and toughness properties of the defective region relate to the applied stress at the defect and defect geometry. The assumptions made in these methodologies are not always representative of the situation accurring in pipeline girth welds. To determine the effect of the various input parameters on acceptable defect size, The Welding Supervisory Committee of the American Gas Association commenced in 1990, in collaboration with the Laboratorium Soete of the University Gent, Belgium, amore » series of small scale (Charpy V impact and CTOD) and large scale (fatigue pre-cracked wide plate) tests. All the experimental investigations were intended to evaluate the effects of weld metal mis-match, temperature, defect size, defect type, defect interaction, pipe wall thickness and yield to tensile ratio on girth weld fracture behaviour. The aim of this report was to determine how weld metal yield strength overmatching or undermatching influences girth weld defect size prediction. A further analysis was conducted using the newly revised PD6493:1991 to provide a critical analysis with the objective of explaining the behaviour of the wide plate tests.« less

  3. Pulmonary atresia

    MedlinePlus

    ... possible, but depend on the extent of the heart abnormalities that accompany the pulmonary valve defect. Potential treatments include: A thin, flexible tube (heart catheterization) to repair the problem Open heart surgery ...

  4. Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facility at Site 300 of the Lawrence Livermore National Laboratory Volume 1: Report of Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gallegos, G; Daniels, J; Wegrecki, A

    2006-04-24

    This document contains the human health and ecological risk assessment for the Resource Recovery and Conservation Act (RCRA) permit renewal for the Explosives Waste Treatment Facility (EWTF). Volume 1 is the text of the risk assessment, and Volume 2 (provided on a compact disc) is the supporting modeling data. The EWTF is operated by the Lawrence Livermore National Laboratory (LLNL) at Site 300, which is located in the foothills between the cities of Livermore and Tracy, approximately 17 miles east of Livermore and 8 miles southwest of Tracy. Figure 1 is a map of the San Francisco Bay Area, showingmore » the location of Site 300 and other points of reference. One of the principal activities of Site 300 is to test what are known as ''high explosives'' for nuclear weapons. These are the highly energetic materials that provide the force to drive fissionable material to criticality. LLNL scientists develop and test the explosives and the integrated non-nuclear components in support of the United States nuclear stockpile stewardship program as well as in support of conventional weapons and the aircraft, mining, oil exploration, and construction industries. Many Site 300 facilities are used in support of high explosives research. Some facilities are used in the chemical formulation of explosives; others are locations where explosive charges are mechanically pressed; others are locations where the materials are inspected radiographically for such defects as cracks and voids. Finally, some facilities are locations where the machined charges are assembled before they are sent to the on-site test firing facilities, and additional facilities are locations where materials are stored. Wastes generated from high-explosives research are treated by open burning (OB) and open detonation (OD). OB and OD treatments are necessary because they are the safest methods for treating explosives wastes generated at these facilities, and they eliminate the requirement for further handling and transportation that would be required if the wastes were treated off site.« less

  5. The safest parameters for FUS-induced blood-brain barrier opening without effects on the opening volume

    NASA Astrophysics Data System (ADS)

    Tung, Yao-Sheng; Olumolade, Yemi; Wang, Shutao; Wu, Shih-Ying; Konofagou, Elisa E.

    2012-11-01

    Acoustic cavitation has been identified as the main physical mechanism for the focused ultrasound (FUS) induced blood-brain barrier (BBB) opening. In this paper, the mechanism of stable cavitation (SC) and inertial cavitation (IC) responsible for BBB opening was investigated. Thirty-three (n=33) mice were intravenously injected with bubbles of 4-5 μm in diameter. The right hippocampus was then sonicated using focused 1.5-MHz ultrasound and three different studies were carried out. First, pulse lengths (PLs) of 0.1, 0.5, 2, and 5 ms at 0.18- MPa peak rarefactional pressure with 5-Hz pulse repetition frequency (PRF) and 5-minute duration were used to identify the threshold of PL using SC. Second, the effects of the duty cycle and exposure time were investigated. Third, the BBB opening size was compared between the SC and the IC. In the case of IC-induced BBB opening, a burst sequence (3-cycles PL; 5-Hz burst repetition frequency (BRF); 30 s duration) at 0.45 MPa was applied. Passive cavitation detection was performed with each sonication to detect whether a broadband response was obtained, i.e., if IC occurred, during BBB opening. The properties of BBB opening were measured through MRI. The threshold of PL for BBB opening was identified between 0.1 and 0.5 ms using SC, but the BBB can be opened in few cycles using IC. The BBB opening volume and normalized intensity increased with the PL, but reached saturation when the PL was above 2 ms. Once the PL threshold was reached, the same exposure time induced a similar BBB opening volume, but longer sonication duration induced higher MR intensity. The duty cycle was found not to play an important role on the BBB opening. Comparable BBB opening volume (20-25 mm3) could be reached between long PL (7500 cycles, i.e., 5 ms) at 0.18 MPa and 3 cycles at 0.45 MPa. 3-kDa fluorescently tagged dextran may be able to diffuse to the parenchyma after IC-induced BBB opening at 0.45 MPa but not after SC-induced BBB opening at 0.18 MPa.

  6. A Micro-Ark for Cells: Highly Open Porous Polyhydroxyalkanoate Microspheres as Injectable Scaffolds for Tissue Regeneration.

    PubMed

    Wei, Dai-Xu; Dao, Jin-Wei; Chen, Guo-Qiang

    2018-06-19

    To avoid large open surgery using scaffold transplants, small-sized cell carriers are employed to repair complexly shaped tissue defects. However, most cell carriers show poor cell adherences and viability. Therefore, polyhydroxyalkanoate (PHA), a natural biopolymer, is used to prepare highly open porous microspheres (OPMs) of 300-360 µm in diameter, combining the advantages of microspheres and scaffolds to serve as injectable carriers harboring proliferating stem cells. In addition to the convenient injection to a defected tissue, and in contrast to poor performances of OPMs made of polylactides (PLA OPMs) and traditional less porous hollow microspheres (PHA HMs), PHA OPMs present suitable surface pores of 10-60 µm and interconnected passages with an average size of 8.8 µm, leading to a high in vitro cell adhesion of 93.4%, continuous proliferation for 10 d and improved differentiation of human bone marrow mesenchymal stem cells (hMSCs). PHA OPMs also support stronger osteoblast-regeneration compared with traditional PHA HMs, PLA OPMs, commercial hyaluronic acid hydrogels, and carrier-free hMSCs in an ectopic bone-formation mouse model. PHA OPMs protect cells against stresses during injection, allowing more living cells to proliferate and migrate to damaged tissues. They function like a micro-Noah's Ark to safely transport cells to a defect tissue. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Classification and printability of EUV mask defects from SEM images

    NASA Astrophysics Data System (ADS)

    Cho, Wonil; Price, Daniel; Morgan, Paul A.; Rost, Daniel; Satake, Masaki; Tolani, Vikram L.

    2017-10-01

    Classification and Printability of EUV Mask Defects from SEM images EUV lithography is starting to show more promise for patterning some critical layers at 5nm technology node and beyond. However, there still are many key technical obstacles to overcome before bringing EUV Lithography into high volume manufacturing (HVM). One of the greatest obstacles is manufacturing defect-free masks. For pattern defect inspections in the mask-shop, cutting-edge 193nm optical inspection tools have been used so far due to lacking any e-beam mask inspection (EBMI) or EUV actinic pattern inspection (API) tools. The main issue with current 193nm inspection tools is the limited resolution for mask dimensions targeted for EUV patterning. The theoretical resolution limit for 193nm mask inspection tools is about 60nm HP on masks, which means that main feature sizes on EUV masks will be well beyond the practical resolution of 193nm inspection tools. Nevertheless, 193nm inspection tools with various illumination conditions that maximize defect sensitivity and/or main-pattern modulation are being explored for initial EUV defect detection. Due to the generally low signal-to-noise in the 193nm inspection imaging at EUV patterning dimensions, these inspections often result in hundreds and thousands of defects which then need to be accurately reviewed and dispositioned. Manually reviewing each defect is difficult due to poor resolution. In addition, the lack of a reliable aerial dispositioning system makes it very challenging to disposition for printability. In this paper, we present the use of SEM images of EUV masks for higher resolution review and disposition of defects. In this approach, most of the defects detected by the 193nm inspection tools are first imaged on a mask SEM tool. These images together with the corresponding post-OPC design clips are provided to KLA-Tencor's Reticle Decision Center (RDC) platform which provides ADC (Automated Defect Classification) and S2A (SEM-to-Aerial printability) analysis of every defect. First, a defect-free or reference mask SEM is rendered from the post-OPC design, and the defective signature is detected from the defect-reference difference image. These signatures help assess the true nature of the defect as evident in e-beam imaging; for example, excess or missing absorber, line-edge roughness, contamination, etc. Next, defect and reference contours are extracted from the grayscale SEM images and fed into the simulation engine with an EUV scanner model to generate corresponding EUV defect and reference aerial images. These are then analyzed for printability and dispositioned using an Aerial Image Analyzer (AIA) application to automatically measure and determine the amount of CD errors. Thus by integrating EUV ADC and S2A applications together, every defect detection is characterized for its type and printability which is essential for not only determining which defects to repair, but also in monitoring the performance of EUV mask process tools. The accuracy of the S2A print modeling has been verified with other commercially-available simulators, and will also be verified with actual wafer print results. With EUV lithography progressing towards volume manufacturing at 5nm technology, and the likelihood of EBMI inspectors approaching the horizon, the EUV ADC-S2A system will continue serving an essential role of dispositioning defects off e-beam imaging.

  8. Clustered vacancies in ZnO: chemical aspects and consequences on physical properties

    NASA Astrophysics Data System (ADS)

    Pal, S.; Gogurla, N.; Das, Avishek; Singha, S. S.; Kumar, Pravin; Kanjilal, D.; Singha, A.; Chattopadhyay, S.; Jana, D.; Sarkar, A.

    2018-03-01

    The chemical nature of point defects, their segregation, cluster or complex formation in ZnO is an important area of investigation. The evolution of a defective state with MeV Ar ion irradiation fluence 1  ×  1014 and 1  ×  1016 ions cm-2 has been monitored here using x-ray photoelectron spectroscopy (XPS), photoluminescence (PL) and Raman spectroscopy. The XPS study shows the presence of oxygen vacancies (V O) in Ar irradiated ZnO. Zn(LMM) Auger spectra clearly identifies a transition involving metallic zinc in the irradiated samples. An intense PL emission from interstitial Zn (I Zn)-related shallow donor bound excitons (DBX) is visible in the 10 K spectra for all samples. Although overall PL is largely reduced with irradiation disorder, DBX intensity is increased for the highest fluence irradiated sample. The Raman study indicates damage in both the zinc and oxygen sub-lattice by an energetic ion beam. Representative Raman modes from defect complexes involving V O, I Zn and I O are visible after irradiation with intermediate fluence. A further increase of fluence shows, to some extent, a homogenization of disorder. A huge reduction of resistance is also noted for this sample. Certainly, high irradiation fluence induces a qualitative modification of the conventional (and highly resistive) grain boundary (GB) structure of granular ZnO. A low resistive path, involving I Zn related shallow donors, across the GB can be presumed to explain resistance reduction. Open volumes (V Zn and V O) agglomerate more and more with increasing irradiation fluence and are finally transformed to voids. The results as a whole have been elucidated with a model which emphasizes the possible evolution of a new defect microstructure that is distinctively different from the GB-related disorder. Based on the model, qualitative explanations of commonly observed radiation hardness, colouration and ferromagnetism in disordered ZnO have been put forward. A coherent scenario on disorder accumulation in ZnO has been presented, which we believe will guide further discussion on this topic.

  9. Augmentation of failed human vertebrae with critical un-contained lytic defect restores their structural competence under functional loading: An experimental study.

    PubMed

    Alkalay, Ron N; von Stechow, Dietrich; Hackney, David B

    2015-07-01

    Lytic spinal lesions reduce vertebral strength and may result in their fracture. Vertebral augmentation is employed clinically to provide mechanical stability and pain relief for vertebrae with lytic lesions. However, little is known about its efficacy in strengthening fractured vertebrae containing lytic metastasis. Eighteen unembalmed human lumbar vertebrae, having simulated uncontained lytic defects and tested to failure in a prior study, were augmented using a transpedicular approach and re-tested to failure using a wedge fracture model. Axial and moment based strength and stiffness parameters were used to quantify the effect of augmentation on the structural response of the failed vertebrae. Effects of cement volume, bone mineral density and vertebral geometry on the change in structural response were investigated. Augmentation increased the failed lytic vertebral strength [compression: 85% (P<0.001), flexion: 80% (P<0.001), anterior-posterior shear: 95%, P<0.001)] and stiffness [(40% (P<0.05), 53% (P<0.05), 45% (P<0.05)]. Cement volume correlated with the compressive strength (r(2)=0.47, P<0.05) and anterior-posterior shear strength (r(2)=0.52, P<0.05) and stiffness (r(2)=0.45, P<0.05). Neither the geometry of the failed vertebrae nor its pre-fracture bone mineral density correlated with the volume of cement. Vertebral augmentation is effective in bolstering the failed lytic vertebrae compressive and axial structural competence, showing strength estimates up to 50-90% of historical values of osteoporotic vertebrae without lytic defects. This modest increase suggests that lytic vertebrae undergo a high degree of structural damage at failure, with strength only partially restored by vertebral augmentation. The positive effect of cement volume is self-limiting due to extravasation. Copyright © 2015. Published by Elsevier Ltd.

  10. Orthodontic treatment of severe anterior open bite and alveolar bone defect complicated by an ankylosed maxillary central incisor: a case report.

    PubMed

    Lin, Feiou; Sun, Hao; Yao, Linjie; Chen, Qiushuo; Ni, Zhenyu

    2014-11-21

    Incisor trauma is common in children, and can cause severe complications during adolescent growth and development. This report describes the treatment of a 16-year-old patient with severe anterior open bite due to ankylosis of the maxillary left incisor after dental trauma as an 8-year-old. No examination or active treatment was undertaken until he was 16 years old. Clinical examination revealed that the maxillary left incisor was severely intruded accompanied by a vertical alveolar bone defect. Orthodontic treatment combined with surgical luxation took 3 years and 7 months. During treatment, the intruded incisor was moved to the occlusal level and the alveolar bone defect was restored, achieving normal occlusion. After two years of retention, the maxillary left incisor was retained in a stable normal position with a slightly reduced overbite. This case demonstrates that surgical luxation with orthodontic traction can be an effective approach, especially when the ankylosed tooth has a single root. Long-term monitoring of orthodontic stability and the maintenance of periodontal health are crucial in the post-treatment period.

  11. NASA Hybrid Reflectometer Project

    NASA Technical Reports Server (NTRS)

    Lynch, Dana; Mancini, Ron (Technical Monitor)

    2002-01-01

    Time-domain and frequency-domain reflectometry have been used for about forty years to locate opens and shorts in cables. Interpretation of reflectometry data is as much art as science. Is there information in the data that is being missed? Can the reflectometers be improved to allow us to detect and locate defects in cables that are not outright shorts or opens? The Hybrid Reflectometer Project was begun this year at NASA Ames Research Center, initially to model wire physics, simulating time-domain reflectometry (TDR) signals in those models and validating the models against actual TDR data taken on testbed cables. Theoretical models of reflectometry in wires will give us an understanding of the merits and limits of these techniques and will guide the application of a proposed hybrid reflectometer with the aim of enhancing reflectometer sensitivity to the point that wire defects can be detected. We will point out efforts by some other researchers to apply wire physics models to the problem of defect detection in wires and we will describe our own initial efforts to create wire physics models and report on testbed validation of the TDR simulations.

  12. Explosive decomposition of a melamine-cyanuric acid supramolecular assembly for fabricating defect-rich nitrogen-doped carbon nanotubes with significantly promoted catalysis.

    PubMed

    Zhao, Zhongkui; Dai, Yitao; Ge, Guifang; Wang, Guiru

    2015-05-26

    A facile and scalable approach for fabricating structural defect-rich nitrogen-doped carbon nanotubes (MCSA-CNTs) through explosive decomposition of melamine-cyanuric acid supramolecular assembly is presented. In comparison to pristine carbon nanotubes, MCSA-CNT exhibits significantly enhanced catalytic performance in oxidant- and steam-free direct dehydrogenation of ethylbenzene, demonstrating the potential for metal-free clean and energy-saving styrene production. This finding also opens a new horizon for preparing highly-efficient carbocatalysts rich in structural defect sites for diverse transformations. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Less severe processing improves carbon nanotube photovoltaic performance

    NASA Astrophysics Data System (ADS)

    Shea, Matthew J.; Wang, Jialiang; Flach, Jessica T.; Zanni, Martin T.; Arnold, Michael S.

    2018-05-01

    Thin film semiconducting single walled carbon nanotube (s-SWCNT) photovoltaics suffer losses due to trapping and quenching of excitons by defects induced when dispersing s-SWCNTs into solution. We study these aspects by preparing photovoltaic devices from (6,5) carbon nanotubes isolated by different processes: extended ultrasonication, brief ultrasonication, and shear force mixing. Peak quantum efficiency increases from 28% to 38% to 49% as the processing harshness decreases and is attributed to both increasing s-SWCNT length and reducing sidewall defects. Fill-factor and open-circuit voltage also improve with shear force mixing, highlighting the importance of obtaining long, defect-free s-SWCNTs for efficient photoconversion devices.

  14. Hybrid photonic-plasmonic crystal nanocavity sensors

    NASA Astrophysics Data System (ADS)

    Cheng, Pi-Ju; Chiang, Chih-Kai; Chou, Bo-Tsun; Huang, Zhen-Ting; Ku, Yun-Cheng; Kuo, Mao-Kuen; Hsu, Jin-Chen; Lin, Tzy-Rong

    2018-02-01

    We have investigated a hybrid photonic-plasmonic crystal nanocavity consisting of a silicon grating nanowire adjacent to a metal surface with a gain gap between them. The hybrid plasmonic cavity modes are highly confined in the gap due to the strong coupling of the photonic crystal cavity modes and the surface plasmonic gap modes. Using finite-element method (FEM), guided modes of the hybrid plasmonic waveguide (WG) were numerically determined at a wavelength of 1550 nm. The modal characteristics such as WG confinement factors and modal losses of the fundamental hybrid plasmonic modes were obtained as a function of groove depth at various gap heights. Furthermore, the band structure of the hybrid crystal modes corresponding to a wide band gap of 17.8 THz is revealed. To enclose the optical energy effectively, a single defect was introduced into the hybrid crystal. At a deep subwavelength defect length as small as 270 nm, the resonant mode exhibits a high quality factor of 567 and an ultrasmall mode volume of 1.9 × 10- 3 ( λ/ n eff)3 at the resonance wavelength of 1550 nm. Compared to conventional photonic crystal nanowire cavities in the absence of a metal surface, the factor Q/ V m is significantly enhanced by about 15 times. The designed hybrid photonic-plasmonic cavity sensors exhibit distinguished characteristics such as sensitivity of 443 nm/RIU and figure of merit of 129. The proposed nanocavities open new possibilities for various applications with strong light-matter interaction, such as biosensors and nanolasers.

  15. Defective Store-Operated Calcium Entry Causes Partial Nephrogenic Diabetes Insipidus

    PubMed Central

    Mamenko, Mykola; Dhande, Isha; Tomilin, Viktor; Zaika, Oleg; Boukelmoune, Nabila; Zhu, Yaming; Gonzalez-Garay, Manuel L.

    2016-01-01

    Store-operated calcium entry (SOCE) is the mechanism by which extracellular signals elicit prolonged intracellular calcium elevation to drive changes in fundamental cellular processes. Here, we investigated the role of SOCE in the regulation of renal water reabsorption, using the inbred rat strain SHR-A3 as an animal model with disrupted SOCE. We found that SHR-A3, but not SHR-B2, have a novel truncating mutation in the gene encoding stromal interaction molecule 1 (STIM1), the endoplasmic reticulum calcium (Ca2+) sensor that triggers SOCE. Balance studies revealed increased urine volume, hypertonic plasma, polydipsia, and impaired urinary concentrating ability accompanied by elevated circulating arginine vasopressin (AVP) levels in SHR-A3 compared with SHR-B2. Isolated, split-open collecting ducts (CD) from SHR-A3 displayed decreased basal intracellular Ca2+ levels and a major defect in SOCE. Consequently, AVP failed to induce the sustained intracellular Ca2+ mobilization that requires SOCE in CD cells from SHR-A3. This effect decreased the abundance of aquaporin 2 and enhanced its intracellular retention, suggesting impaired sensitivity of the CD to AVP in SHR-A3. Stim1 knockdown in cultured mpkCCDc14 cells reduced SOCE and basal intracellular Ca2+ levels and prevented AVP-induced translocation of aquaporin 2, further suggesting the effects in SHR-A3 result from the expression of truncated STIM1. Overall, these results identify a novel mechanism of nephrogenic diabetes insipidus and uncover a role of SOCE in renal water handling. PMID:26574044

  16. Photoluminescence Spectroscopy | Photovoltaic Research | NREL

    Science.gov Websites

    capabilities include: various excitation wavelengths that allow for varying levels of volume excitation; a efficiency. Impurity Levels and Defect Detection. The PL spectrum at low sample temperatures often reveals

  17. Haemodynamic changes in hepatocellular carcinoma and liver parenchyma under balloon occlusion of the hepatic artery.

    PubMed

    Sugihara, Fumie; Murata, Satoru; Ueda, Tatsuo; Yasui, Daisuke; Yamaguchi, Hidenori; Miki, Izumi; Kawamoto, Chiaki; Uchida, Eiji; Kumita, Shin-Ichiro

    2017-06-01

    To investigate haemodynamic changes in hepatocellular carcinoma (HCC) and liver under hepatic artery occlusion. Thirty-eight HCC nodules in 25 patients were included. Computed tomography (CT) during hepatic arteriography (CTHA) with and without balloon occlusion of the hepatic artery was performed. CT attenuation and enhancement volume of HCC and liver with and without balloon occlusion were measured on CTHA. Influence of balloon position (segmental or subsegmental branch) was evaluated based on differences in HCC-to-liver attenuation ratio (H/L ratio) and enhancement volume of HCC and liver. In the segmental group (n = 20), H/L ratio and enhancement volume of HCC and liver were significantly lower with balloon occlusion than without balloon occlusion. However, in the subsegmental group (n = 18), H/L ratio was significantly higher and liver enhancement volume was significantly lower with balloon occlusion; HCC enhancement volume was similar with and without balloon occlusion. Rate of change in H/L ratio and enhancement volume of HCC and liver were lower in the segmental group than in the subsegmental group. There were significantly more perfusion defects in HCC in the segmental group. Hepatic artery occlusion causes haemodynamic changes in HCC and liver, especially with segmental occlusion. • Hepatic artery occlusion causes haemodynamic changes in hepatocellular carcinoma and liver. • Segmental occlusion decreased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Subsegmental occlusion increased rate of change in hepatocellular carcinoma-to-liver attenuation ratio. • Hepatic artery occlusion decreased enhancement volume of hepatocellular carcinoma and liver. • Hepatic artery occlusion causes perfusion defects in hepatocellular carcinoma.

  18. Experimental investigation of defect criticality in FRP laminate composites

    NASA Astrophysics Data System (ADS)

    Joyce, Peter James

    1999-11-01

    This work examines the defect criticality of fiber reinforced polymer Composites. The objective is to determine the sensitivity of the finished composite to various process-induced defects. This work focuses on two different classes of process-induced defects; (1) fiber waviness in high performance carbon-fiber reinforced unidirectional composites and (2) void volume in low cost glass-fabric reinforced composites. The role of fiber waviness in the compressive response of unidirectional composites has been studied by a number of other investigators. Because of difficulties associated with producing real composites with varying levels of fiber waviness, most experimental studies of fiber waviness have evaluated composites with artificially induced fiber waviness. Furthermore, most experimental studies have been concentrated on the effects of out-of-plane fiber waviness. The objective of this work is to evaluate the effects of in-plane fiber waviness naturally occurring in autoclave consolidated thermoplastic laminates. The first phase of this project involved the development of a simple technique for measuring the resulting fiber waviness levels. An experimental investigation of the compression strength reduction in composites with in-plane fiber waviness followed. The experimental program included carbon-fiber reinforced thermoplastic composites manufactured from prepreg tape by hand layup, and carbon-fiber and glass-fiber reinforced composites manufactured from an experimental powder towpreg by filament winding and autoclave consolidation. The compression specimens exhibited kink band failure in the prepreg composite and varying amounts of longitudinal splitting and kink banding in the towpreg composites. The compression test results demonstrated the same trend as predicted by microbudding theory but the overall quantitative correlation was poor. The second thrust of this research evaluated void effects in resin transfer molded composites. Much of the existing literature in this area has focused on composites with unidirectional fiber reinforcement. In this program, the influence of void volume on the mechanical behavior of RTM composites with plain weave reinforcement was investigated. The experimental program demonstrated that the effects of void volume are negligible in terms of the fiber dominated properties. Interlaminar shear strength tests on the other hand demonstrated a linear dependence on void volume in the range tested.

  19. POLLUTION EFFECTS OF ABNORMAL OPERATIONS IN IRON AND STEEL MAKING. VOLUME IV. OPEN HEARTH FURNACE, MANUAL OF PRACTICE

    EPA Science Inventory

    The report is one in a six-volume series considering abnormal operating conditions (AOCs) in the primary section (sintering, blast furnace ironmaking, open hearth, electric furnace, and basic oxygen steelmaking) of an integrated iron and steel plant. Pollution standards, generall...

  20. Physics and Applications of Defects in Advanced Semiconductors. Materials Research Society Symposium Proceedings. Volume 325

    DTIC Science & Technology

    1994-01-01

    MAGNETOOPTICAL STUDIES OF ACCEPTORS CONFINED IN GaAs/AMGaAs QUANTUM WELLS ............................................... 73 P.O. Holtz, Q.X. Zhao, B. Momar...PROBE-PROBE TRANSMISSION STUDIES OF LT-GROWN GaAs NEAR THE BAND EDGE ...................................... 389 H.B. Radousky, A.F. Bello, DJ. Erskine...SUBSTRATE ...................... 449 M. Shah, M.O. Manareh, R. Kaspi, M.Y. Yen, B.A. Philips, M. Skowronki, and J. Shi•rm A TEM STUDY OF DEFECT STRUCTURE IN

  1. Contribution of olivofloccular circuitry developmental defects to atypical gaze in autism

    PubMed Central

    Wegiel, Jerzy; Kuchna, Izabela; Nowicki, Krzysztof; Imaki, Humi; Wegiel, Jarek; Ma, Shuang Yong; Azmitia, Efrain C.; Banerjee, Probal; Flory, Michael; Cohen, Ira L.; London, Eric; Brown, W. Ted; Hare, Carolyn Komich; Wisniewski, Thomas

    2014-01-01

    Individuals with autism demonstrate atypical gaze, impairments in smooth pursuit, altered movement perception and deficits in facial perception. The olivofloccular neuronal circuit is a major contributor to eye movement control. This study of the cerebellum in 12 autistic and 10 control subjects revealed dysplastic changes in the flocculus of eight autistic (67%) and two control (20%) subjects. Defects of the oculomotor system, including avoidance of eye contact and poor or no eye contact, were reported in 88% of autistic subjects with postmortem-detected floccular dysplasia. Focal disorganization of the flocculus cytoarchitecture with deficit, altered morphology, and spatial disorientation of Purkinje cells (PCs); deficit and abnormalities of granule, basket, stellate and unipolar brush cells; and structural defects and abnormal orientation of Bergmann glia are indicators of profound disruption of flocculus circuitry in a dysplastic area. The average volume of PCs was 26% less in the dysplastic region than in the unaffected region of the flocculus (p<0.01) in autistic subjects. Moreover, the average volume of PCs in the entire cerebellum was 25% less in the autistic subjects than in the control subjects (p<0.001). Findings from this study and a parallel study of the inferior olive (IO) suggest that focal floccular dysplasia combined with IO neurons and PC developmental defects may contribute to oculomotor system dysfunction and atypical gaze in autistic subjects. PMID:23558308

  2. Development of a 3D log sawing optimization system for small sawmills in central Appalachia, US

    Treesearch

    Wenshu Lin; Jingxin Wang; Edward Thomas

    2011-01-01

    A 3D log sawing optimization system was developed to perform log generation, opening face determination, sawing simulation, and lumber grading using 3D modeling techniques. Heuristic and dynamic programming algorithms were used to determine opening face and grade sawing optimization. Positions and shapes of internal log defects were predicted using a model developed by...

  3. Guanidinium: A Route to Enhanced Carrier Lifetime and Open-Circuit Voltage in Hybrid Perovskite Solar Cells.

    PubMed

    De Marco, Nicholas; Zhou, Huanping; Chen, Qi; Sun, Pengyu; Liu, Zonghao; Meng, Lei; Yao, En-Ping; Liu, Yongsheng; Schiffer, Andy; Yang, Yang

    2016-02-10

    Hybrid perovskites have shown astonishing power conversion efficiencies owed to their remarkable absorber characteristics including long carrier lifetimes, and a relatively substantial defect tolerance for solution-processed polycrystalline films. However, nonradiative charge carrier recombination at grain boundaries limits open circuit voltages and consequent performance improvements of perovskite solar cells. Here we address such recombination pathways and demonstrate a passivation effect through guanidinium-based additives to achieve extraordinarily enhanced carrier lifetimes and higher obtainable open circuit voltages. Time-resolved photoluminescence measurements yield carrier lifetimes in guanidinium-based films an order of magnitude greater than pure-methylammonium counterparts, giving rise to higher device open circuit voltages and power conversion efficiencies exceeding 17%. A reduction in defect activation energy of over 30% calculated via admittance spectroscopy and confocal fluorescence intensity mapping indicates successful passivation of recombination/trap centers at grain boundaries. We speculate that guanidinium ions serve to suppress formation of iodide vacancies and passivate under-coordinated iodine species at grain boundaries and within the bulk through their hydrogen bonding capability. These results present a simple method for suppressing nonradiative carrier loss in hybrid perovskites to further improve performances toward highly efficient solar cells.

  4. Microvascular transplants in head and neck reconstruction: 3D evaluation of volume loss.

    PubMed

    Bittermann, Gido; Thönissen, Philipp; Poxleitner, Philipp; Zimmerer, Ruediger; Vach, Kirstin; Metzger, Marc C

    2015-10-01

    Despite oversized latissimus dorsi free flap reconstruction in the head and neck area, esthetic and functional problems continue to exist due to the well-known occurrence of transplant shrinkage. The purpose of this study was to acquire an estimation of the volume and time of the shrinkage process. The assessment of volume loss was performed using a 3D evaluation of two postoperative CT scans. A retrospective review was conducted on all latissimus dorsi free flap reconstructions performed between 2004 and 2013. Inclusion criteria for the assessment were: resection of an oral carcinoma and microsurgical defect coverage with latissimus dorsi free flap; a first postoperative CT (CT1) performed between 3 weeks and a maximum of 3 months after reconstruction surgery; and an additional CT scan (CT2) performed at least one year postoperatively. The exclusion criterion was surgical intervention in the local area between the acquisition of CT1 and CT2. The effect of adjuvant radiation therapy was considered. Volume determination of the transplant was carried out in CT1 and CT2 by manual segmentation of the graft. Fifteen patients were recruited. 3D evaluation showed an average volume loss of 34.4%. In the consideration of postoperative radiotherapy the volume reduction was 39.2% in patients with radiotherapy and 31.3% in patients without radiotherapy. The reconstruction flap volume required for overcorrection of the surgical defect was investigated. This study indicates that a volume loss of more than 30% could be expected one or more years after latissimus dorsi free flap reconstruction. Clinical trial number DRKS00007534. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  5. Seasoning and surfacing degrade in kiln-drying ponderosa pine in eastern Washington.

    Treesearch

    A.C. Knauss; E.H. Clarke

    1961-01-01

    This report presents results of a study to determine the degrade (loss in volume and value) of ponderosa pine lumber when cut, kiln-dried, and surfaced in accordance with commercial practice. The study measured (1) loss in volume due to culling and trimming surfaced dry lumber because of sawing, seasoning, and surfacing defects; (2) reduction in grade due to seasoning...

  6. Seasoning and surfacing degrade in kiln-drying western hemlock in western Oregon.

    Treesearch

    A.C. Knauss; E.H. Clarke

    1961-01-01

    This report presents the results of a study to determine the degrade (loss in volume and value) of western hemlock lumber cut, kiln-dried, and surfaced in accordance with commercial practice in western Oregon. The study measured (1) loss in volume due to culling and trimming surfaced dry lumber because of sawing, seasoning, and surfacing defects; (2) reduction in grade...

  7. Seasoning and surfacing degrade in kiln-drying Douglas-fir in western Oregon.

    Treesearch

    A.C. Knauss; E.H. Clarke

    1959-01-01

    This report presents the results of a study to determine the degrade—loss in volume and grade—of coast-type Douglas-fir lumber when kiln-dried and surfaced in accordance with commercial practice. The study measured (1) loss in volume due to culling and trimming of dry-surfaced lumber because of seasoning and surfacing defects, (2) reduction in grade...

  8. Seasoning degrade in kiln drying ponderosa pine in south central Oregon.

    Treesearch

    A.C. Knauss

    1957-01-01

    This report presents the results of a study to determine the loss in volume and value of lumber when kiln drying and surfacing the production from ponderosa pine logs. The study measured (1) the reduction in volume due to trimming and culling dry lumber after surfacing, (2) the reduction in grade due to seasoning defects, (3) the reduction in grade due to failure of...

  9. Characteristics of residues in a cable-logged area of old-growth Douglas-fir.

    Treesearch

    W.Y. Pong; John W. Henley

    1984-01-01

    The volume and character of woody material on the ground in four old-growth Douglas-fir cutting units in the Cascade Range in Oregon were determined before and after harvesting by cable and yarding of unutilized material (YUM). Total volume of residue increased after logging in all units. Coarse residues were reduced by YUM yarding. Small changes in the defect...

  10. Automated objective characterization of visual field defects in 3D

    NASA Technical Reports Server (NTRS)

    Fink, Wolfgang (Inventor)

    2006-01-01

    A method and apparatus for electronically performing a visual field test for a patient. A visual field test pattern is displayed to the patient on an electronic display device and the patient's responses to the visual field test pattern are recorded. A visual field representation is generated from the patient's responses. The visual field representation is then used as an input into a variety of automated diagnostic processes. In one process, the visual field representation is used to generate a statistical description of the rapidity of change of a patient's visual field at the boundary of a visual field defect. In another process, the area of a visual field defect is calculated using the visual field representation. In another process, the visual field representation is used to generate a statistical description of the volume of a patient's visual field defect.

  11. Topological protection of photonic mid-gap cavity modes

    NASA Astrophysics Data System (ADS)

    Benalcazar, Wladimir A.; Noh, Jiho; Huang, Sheng; Collins, Matthew J.; Chen, Kevin; Hughes, Taylor L.; Rechtsman, Mikael

    Defect modes in two-dimensional periodic photonic structures have found use in a highly diverse set of optical devices. Here, we show in theory and experiment that a photonic topological crystalline insulator structure can be used to generate topological defect-localized modes. These defect modes are protected by chiral and crystalline symmetries, and have resonance frequencies in the middle of the photonic band gap (which minimize the mode volume). This protection of zero-dimensional states (defect modes) embedded in a two-dimensional environment constitutes a novel form of topological protection that has not been previously demonstrated. WAB and TLH are supported by the ONR YIP Award N00014-15-1-2383. M.C.R. and J.N. are supported by NSF, Grant ECCS-1509546; M.C.R. is supported by the Alfred P. Sloan foundation fellowship FG-2016-6418.

  12. Model based inversion of ultrasound data in composites

    NASA Astrophysics Data System (ADS)

    Roberts, R. A.

    2018-04-01

    Work is reported on model-based defect characterization in CFRP composites. The work utilizes computational models of ultrasound interaction with defects in composites, to determine 1) the measured signal dependence on material and defect properties (forward problem), and 2) an assessment of defect properties from analysis of measured ultrasound signals (inverse problem). Work is reported on model implementation for inspection of CFRP laminates containing multi-ply impact-induced delamination, in laminates displaying irregular surface geometry (roughness), as well as internal elastic heterogeneity (varying fiber density, porosity). Inversion of ultrasound data is demonstrated showing the quantitative extraction of delamination geometry and surface transmissivity. Additionally, data inversion is demonstrated for determination of surface roughness and internal heterogeneity, and the influence of these features on delamination characterization is examined. Estimation of porosity volume fraction is demonstrated when internal heterogeneity is attributed to porosity.

  13. A proposed application programming interface for a physical volume repository

    NASA Technical Reports Server (NTRS)

    Jones, Merritt; Williams, Joel; Wrenn, Richard

    1996-01-01

    The IEEE Storage System Standards Working Group (SSSWG) has developed the Reference Model for Open Storage Systems Interconnection, Mass Storage System Reference Model Version 5. This document, provides the framework for a series of standards for application and user interfaces to open storage systems. More recently, the SSSWG has been developing Application Programming Interfaces (APIs) for the individual components defined by the model. The API for the Physical Volume Repository is the most fully developed, but work is being done on APIs for the Physical Volume Library and for the Mover also. The SSSWG meets every other month, and meetings are open to all interested parties. The Physical Volume Repository (PVR) is responsible for managing the storage of removable media cartridges and for mounting and dismounting these cartridges onto drives. This document describes a model which defines a Physical Volume Repository, and gives a brief summary of the Application Programming Interface (API) which the IEEE Storage Systems Standards Working Group (SSSWG) is proposing as the standard interface for the PVR.

  14. The use of polymethyl-methacrylate (Artecoll) as an adjunct to facial reconstruction

    PubMed Central

    Mok, David; Schwarz, Jorge

    2004-01-01

    BACKGROUND: Injectable polymethyl-methacrylate (PMMA) microspheres, or Artecoll, has been used for the last few years in aesthetic surgery as long-term tissue filler for the correction of wrinkles and for lip augmentation. This paper presents three cases of the use of PMMA microsphere injection for reconstructive patients with defects of varying etiologies. These cases provide examples of a novel adjunct to the repertoire of the reconstructive surgeon. OBJECTIVES: To evaluate the effectiveness (short- and long-term) of PMMA injection for the correction of small soft tissue defects of the face. METHODS: Three case histories are presented. They include the origin of the defect; previous reconstructions of the defect; and area, volume, timing and technical particularities of PMMA administration. RESULTS: All three cases showed improvement of the defect with the PMMA injection with respect to both objective evidence and patient satisfaction. The improvements can still be seen after several years. CONCLUSIONS: PMMA microsphere injection can be effectively used to correct selected small facial defects in reconstructive cases and the results are long lasting. PMID:24115873

  15. [Resection of alae nasi malignant and nasolabial flaps pedicled facial prosthetics I period of repair].

    PubMed

    Tuo, Honglian; Yang, Guangdong; Ling, Dan; Ma, Gang

    2010-04-01

    To Discuss nasolabial pedicle flap in the repair of facial malignant asal nasi resection defect after clinical practicality and feasibility. Eleven cases of patients with asal nasi surgery in patients with malignant tumor resection. And in accordance with the characteristics of the blood supply of the nasolabial fold area and the size of design defects to be repaired region length. angle and size, design nasolabial flaps pedicled flap face. Go through the nasal alar defect repair defects. All patients were I wound healing, skins all survived, good blood circulation, good color and no obvious scar area. One year postoperative follow-up to 5 years without recurrence of the tumor, the effect of external nose satisfied with the cosmetic restoration. The nasolabial flap pedicled facial blood rich and easy to survive, organizations can provide sufficient volume to the repair of larger nasal defects, vascular pedicle length, the transfer of a flexible, easy to operate and no obvious scar area. Nasolabial pedicle flap to repair the face of larger asal nasi defects after resection of malignant tumors can choose the best skin.

  16. HVM die yield improvement as a function of DRSEM ADC

    NASA Astrophysics Data System (ADS)

    Maheshwary, Sonu; Haas, Terry; McGarvey, Steve

    2010-03-01

    Given the current manufacturing technology roadmap and the competitiveness of the global semiconductor manufacturing environment in conjunction with the semiconductor manufacturing market dynamics, the market place continues to demand a reduced die manufacturing cost. This continuous pressure on lowering die cost in turn drives an aggressive yield learning curve, a key component of which is defect reduction of manufacturing induced anomalies. In order to meet and even exceed line and die yield targets there is a need to revamp defect classification strategies and place a greater emphasize on increasing the accuracy and purity of the Defect Review Scanning Electron Microscope (DRSEM) Automated Defect Classification (ADC) results while placing less emphasis on the ADC results of patterned/un-patterned wafer inspection systems. The increased emphasis on DRSEM ADC results allows for a high degree of automation and consistency in the classification data and eliminates variance induced by the manufacturing staff. This paper examines the use of SEM based Auto Defect Classification in a high volume manufacturing environment as a key driver in the reduction of defect limited yields.

  17. The transcription factor Nfix is essential for normal brain development.

    PubMed

    Campbell, Christine E; Piper, Michael; Plachez, Céline; Yeh, Yu-Ting; Baizer, Joan S; Osinski, Jason M; Litwack, E David; Richards, Linda J; Gronostajski, Richard M

    2008-05-13

    The Nuclear Factor I (NFI) multi-gene family encodes site-specific transcription factors essential for the development of a number of organ systems. We showed previously that Nfia-deficient mice exhibit agenesis of the corpus callosum and other forebrain defects; Nfib-deficient mice have defects in lung maturation and show callosal agenesis and forebrain defects resembling those seen in Nfia-deficient animals, while Nfic-deficient mice have defects in tooth root formation. Recently the Nfix gene has been disrupted and these studies indicated that there were largely uncharacterized defects in brain and skeletal development in Nfix-deficient mice. Here we show that disruption of Nfix by Cre-recombinase mediated excision of the 2nd exon results in defects in brain development that differ from those seen in Nfia and Nfib KO mice. In particular, complete callosal agenesis is not seen in Nfix-/- mice but rather there appears to be an overabundance of aberrant Pax6- and doublecortin-positive cells in the lateral ventricles of Nfix-/- mice, increased brain weight, expansion of the cingulate cortex and entire brain along the dorsal ventral axis, and aberrant formation of the hippocampus. On standard lab chow Nfix-/- animals show a decreased growth rate from ~P8 to P14, lose weight from ~P14 to P22 and die at ~P22. If their food is supplemented with a soft dough chow from P10, Nfix-/- animals show a lag in weight gain from P8 to P20 but then increase their growth rate. A fraction of the animals survive to adulthood and are fertile. The weight loss correlates with delayed eye and ear canal opening and suggests a delay in the development of several epithelial structures in Nfix-/- animals. These data show that Nfix is essential for normal brain development and may be required for neural stem cell homeostasis. The delays seen in eye and ear opening and the brain morphology defects appear independent of the nutritional deprivation, as rescue of perinatal lethality with soft dough does not eliminate these defects.

  18. A catchment-scale groundwater model including sewer pipe leakage in an urban system

    NASA Astrophysics Data System (ADS)

    Peche, Aaron; Fuchs, Lothar; Spönemann, Peter; Graf, Thomas; Neuweiler, Insa

    2016-04-01

    Keywords: pipe leakage, urban hydrogeology, catchment scale, OpenGeoSys, HYSTEM-EXTRAN Wastewater leakage from subsurface sewer pipe defects leads to contamination of the surrounding soil and groundwater (Ellis, 2002; Wolf et al., 2004). Leakage rates at pipe defects have to be known in order to quantify contaminant input. Due to inaccessibility of subsurface pipe defects, direct (in-situ) measurements of leakage rates are tedious and associated with a high degree of uncertainty (Wolf, 2006). Proposed catchment-scale models simplify leakage rates by neglecting unsaturated zone flow or by reducing spatial dimensions (Karpf & Krebs, 2013, Boukhemacha et al., 2015). In the present study, we present a physically based 3-dimensional numerical model incorporating flow in the pipe network, in the saturated zone and in the unsaturated zone to quantify leakage rates on the catchment scale. The model consists of the pipe network flow model HYSTEM-EXTAN (itwh, 2002), which is coupled to the subsurface flow model OpenGeoSys (Kolditz et al., 2012). We also present the newly developed coupling scheme between the two flow models. Leakage functions specific to a pipe defect are derived from simulations of pipe leakage using spatially refined grids around pipe defects. In order to minimize computational effort, these leakage functions are built into the presented numerical model using unrefined grids around pipe defects. The resulting coupled model is capable of efficiently simulating spatially distributed pipe leakage coupled with subsurficial water flow in a 3-dimensional environment. References: Boukhemacha, M. A., Gogu, C. R., Serpescu, I., Gaitanaru, D., & Bica, I. (2015). A hydrogeological conceptual approach to study urban groundwater flow in Bucharest city, Romania. Hydrogeology Journal, 23(3), 437-450. doi:10.1007/s10040-014-1220-3. Ellis, J. B., & Revitt, D. M. (2002). Sewer losses and interactions with groundwater quality. Water Science and Technology, 45(3), 195-202. itwh (2002). Modellbeschreibung, Institut für technisch-wissenschaftliche Hydrologie GmbH, Hannover. Karpf, C. & Krebs, P. (2013). Modelling of groundwater infiltration into sewer systems. Urban Water Journal, 10:4, 221-229, DOI: 10.1080/1573062X.2012.724077. Kolditz, O., Bauer, S. et al. (2012). OpenGeoSys: an open source initiative for numerical simulation of thermo-hydro-mechanical/chemical (THM/C) processes in porous media. Env. Earth Sci. 67(2):589-599. Wolf, L., Held, I., Eiswirth, M., & Hötzl, H. (2004). Impact of leaky sewers on groundwater quality. Acta Hydrochimica et Hydrobiologica, 32(4-5), 361-373. doi:10.1002/aheh.200400538. Wolf, L. (2006). Influence of leaky sewer systems on groundwater resources beneath the city of Rastatt, Germany. Dissertation, University of Karlsruhe.

  19. Loratadine and Pregnancy

    MedlinePlus

    ... with several limitations suggested a small risk for hypospadias (a condition where the opening of the penis ... risk of any type of birth defect, including hypospadias. Also, studies involving infants with hypospadias did not ...

  20. Unjoined primary and secondary neural tubes: junctional neural tube defect, a new form of spinal dysraphism caused by disturbance of junctional neurulation.

    PubMed

    Eibach, Sebastian; Moes, Greg; Hou, Yong Jin; Zovickian, John; Pang, Dachling

    2017-10-01

    Primary and secondary neurulation are the two known processes that form the central neuraxis of vertebrates. Human phenotypes of neural tube defects (NTDs) mostly fall into two corresponding categories consistent with the two types of developmental sequence: primary NTD features an open skin defect, an exposed, unclosed neural plate (hence an open neural tube defect, or ONTD), and an unformed or poorly formed secondary neural tube, and secondary NTD with no skin abnormality (hence a closed NTD) and a malformed conus caudal to a well-developed primary neural tube. We encountered three cases of a previously unrecorded form of spinal dysraphism in which the primary and secondary neural tubes are individually formed but are physically separated far apart and functionally disconnected from each other. One patient was operated on, in whom both the lumbosacral spinal cord from primary neurulation and the conus from secondary neurulation are each anatomically complete and endowed with functioning segmental motor roots tested by intraoperative triggered electromyography and direct spinal cord stimulation. The remarkable feature is that the two neural tubes are unjoined except by a functionally inert, probably non-neural band. The developmental error of this peculiar malformation probably occurs during the critical transition between the end of primary and the beginning of secondary neurulation, in a stage aptly called junctional neurulation. We describe the current knowledge concerning junctional neurulation and speculate on the embryogenesis of this new class of spinal dysraphism, which we call junctional neural tube defect.

  1. Consumer acceptable risk: how cigarette companies have responded to accusations that their products are defective

    PubMed Central

    Cummings, K Michael; Brown, Anthony; Douglas, Clifford E

    2006-01-01

    Objective To describe arguments used by cigarette companies to defend themselves against charges that their cigarettes were defective and that they could and should have done more to make cigarettes less hazardous. Methods The data for this paper come from the opening statements made by defendants in four court cases: two class action lawsuits (Engle 1999, and Blankenship 2001) and two individual cases (Boeken 2001, and Schwarz 2002). The transcripts of opening statements were reviewed and statements about product defect claims, product testing, and safe cigarette research were excerpted and coded. Results Responses by cigarette companies to charges that their products were defective has been presented consistently across different cases and by different companies. Essentially the arguments made by cigarette companies boil down to three claims: (1) smoking is risky, but nothing the companies have done has made cigarettes more dangerous than might otherwise be the case; (2) nothing the companies have done or said has kept someone from stopping smoking; and (3) the companies have spent lots of money to make the safest cigarette acceptable to the smoker. Conclusions Cigarette companies have argued that their products are inherently dangerous but not defective, and that they have worked hard to make their products safer by lowering the tar and nicotine content of cigarettes as recommended by members of the public health community. As a counter argument, plaintiff attorneys should focus on how cigarette design changes have actually made smoking more acceptable to smokers, thereby discouraging smoking cessation. PMID:17130628

  2. Microcomputed tomographic and histomorphometric analyses of novel titanium mesh membranes for guided bone regeneration: a study in rat calvarial defects.

    PubMed

    Rakhmatia, Yunia Dwi; Ayukawa, Yasunori; Furuhashi, Akihiro; Koyano, Kiyoshi

    2014-01-01

    The objective of this study was to evaluate the optimal thickness and porosity of novel titanium mesh membranes to enhance bone augmentation, prevent soft tissue ingrowth, and prevent membrane exposure. Six types of novel titanium meshes with different thicknesses and pore sizes, along with three commercially available membranes, were used to cover surgically created calvarial defects in 6-week-old Sprague-Dawley rats. The animals were killed after 4 or 8 weeks. Microcomputed tomographic analyses were performed to analyze the three-dimensional bone volume and bone mineral density. Soft tissue ingrowth was also evaluated histologically and histomorphometrically. The novel titanium membranes used in this study were as effective at augmenting bone in the rat calvarial defect model as the commercially available membranes. The greatest bone volume was observed on 100-μm-thick membranes with larger pores, although these membranes promoted growth of bone with lower mineral density. Soft tissue ingrowth when 100-μm membranes were used was increased at 4 weeks but decreased again by 8 weeks to a level not statistically significantly different from other membranes. Membrane thickness affects the total amount of new bone formation, and membrane porosity is an essential factor for guided bone regeneration, especially during the initial healing period, although the final bone volume obtained is essentially the same. Newly developed titanium mesh membranes of 100 μm in thickness and with large pores appear to be optimal for guided bone regeneration.

  3. New bone formation in a bone defect associated to dental implant using absorbable or non-absorbable membrane in a dog model

    PubMed Central

    Lopez, Maria de Almeida; Olate, Sergio; Lanata-Flores, Antonio; Pozzer, Leandro; Cavalieri-Pereira, Lucas; Cantín, Mario; Vásquez, Bélgica; de Albergaria-Barbosa, José

    2013-01-01

    The aim of this research was to determine the bone formation capacity in fenestration defects associated with dental implants using absorbable and non-absorbable membranes. Six dogs were used in the study. In both tibias of each animal 3 implants were installed, and around these 5 mm circular defects were created. The defects were covered with absorbable membranes (experimental group 1), non-absorbable membranes (experimental group 2), and the third defect was not covered (control group). At 3 and 8 weeks post-surgery, the animals were euthanized and the membranes with the bone tissue around the implants were processed for histological analysis. The statistical analysis was conducted with Tukey’s test, considering statistical significance when p<0.1. Adequate bone repair was observed in the membrane-covered defects. At 3 weeks, organization of the tissue, bone formation from the periphery of the defect and the absence of inflammatory infiltrate were observed in both experimental groups, but the defect covered with absorbable membrane presented statistically greater bone formation. At 8 weeks, both membrane-covered defects showed adequate bone formation without significant differences, although they did in fact present differences with the control defect in both periods (p>0.1). In the defects without membrane, continuous connective tissue invasions and bone repair deficiency were observed. There were no significant differences in the characteristics and volume of the neoformed bone in the defects around the implants covered by the different membranes, whereas the control defects produced significantly less bone. The use of biological membranes contributes to bone formation in three-wall defects. PMID:24228090

  4. Visualizing breathing motion of internal cavities in concert with ligand migration in myoglobin

    PubMed Central

    Tomita, Ayana; Sato, Tokushi; Ichiyanagi, Kouhei; Nozawa, Shunsuke; Ichikawa, Hirohiko; Chollet, Matthieu; Kawai, Fumihiro; Park, Sam-Yong; Tsuduki, Takayuki; Yamato, Takahisa; Koshihara, Shin-ya; Adachi, Shin-ichi

    2009-01-01

    Proteins harbor a number of cavities of relatively small volume. Although these packing defects are associated with the thermodynamic instability of the proteins, the cavities also play specific roles in controlling protein functions, e.g., ligand migration and binding. This issue has been extensively studied in a well-known protein, myoglobin (Mb). Mb reversibly binds gas ligands at the heme site buried in the protein matrix and possesses several internal cavities in which ligand molecules can reside. It is still an open question as to how a ligand finds its migration pathways between the internal cavities. Here, we report on the dynamic and sequential structural deformation of internal cavities during the ligand migration process in Mb. Our method, the continuous illumination of native carbonmonoxy Mb crystals with pulsed laser at cryogenic temperatures, has revealed that the migration of the CO molecule into each cavity induces structural changes of the amino acid residues around the cavity, which results in the expansion of the cavity with a breathing motion. The sequential motion of the ligand and the cavity suggests a self-opening mechanism of the ligand migration channel arising by induced fit, which is further supported by computational geometry analysis by the Delaunay tessellation method. This result suggests a crucial role of the breathing motion of internal cavities as a general mechanism of ligand migration in a protein matrix. PMID:19204297

  5. Openings between Defective Endothelial Cells Explain Tumor Vessel Leakiness

    PubMed Central

    Hashizume, Hiroya; Baluk, Peter; Morikawa, Shunichi; McLean, John W.; Thurston, Gavin; Roberge, Sylvie; Jain, Rakesh K.; McDonald, Donald M.

    2000-01-01

    Leakiness of blood vessels in tumors may contribute to disease progression and is key to certain forms of cancer therapy, but the structural basis of the leakiness is unclear. We sought to determine whether endothelial gaps or transcellular holes, similar to those found in leaky vessels in inflammation, could explain the leakiness of tumor vessels. Blood vessels in MCa-IV mouse mammary carcinomas, which are known to be unusually leaky (functional pore size 1.2–2 μm), were compared to vessels in three less leaky tumors and normal mammary glands. Vessels were identified by their binding of intravascularly injected fluorescent cationic liposomes and Lycopersicon esculentum lectin and by CD31 (PECAM) immunoreactivity. The luminal surface of vessels in all four tumors had a defective endothelial monolayer as revealed by scanning electron microscopy. In MCa-IV tumors, 14% of the vessel surface was lined by poorly connected, overlapping cells. The most superficial lining cells, like endothelial cells, had CD31 immunoreactivity and fenestrae with diaphragms, but they had a branched phenotype with cytoplasmic projections as long as 50 μm. Some branched cells were separated by intercellular openings (mean diameter 1.7 μm; range, 0.3–4.7 μm). Transcellular holes (mean diameter 0.6 μm) were also present but were only 8% as numerous as intercellular openings. Some CD31-positive cells protruded into the vessel lumen; others sprouted into perivascular tumor tissue. Tumors in RIP-Tag2 mice had, in addition, tumor cell-lined lakes of extravasated erythrocytes. We conclude that some tumor vessels have a defective cellular lining composed of disorganized, loosely connected, branched, overlapping or sprouting endothelial cells. Openings between these cells contribute to tumor vessel leakiness and may permit access of macromolecular therapeutic agents to tumor cells. PMID:10751361

  6. Finite element analysis of Al 2024/Cu-Al-Ni shape memory alloy composites with defects/cracks

    NASA Astrophysics Data System (ADS)

    Kotresh, M.; Benal, M. M., Dr; Siddalinga Swamy, N. H., Dr

    2018-02-01

    In this work, a numerical approach to predict the stress field behaviour of defect/crack in shape memory alloy (SMA) particles reinforced composite known as the adaptive composite is presented. Simulation is based on the finite element method. The critical stress field approach was used to determine the stresses around defect/crack. Thereby stress amplification issue is being resolved. In this paper, the effect volume % of shape memory alloy and shape memory effect of reinforcement for as-cast and SME trained composites are examined and discussed. Shape memory effect known as training is achieved by pre-straining of reinforcement particles by equivalent changes in their expansion coefficients.

  7. Defining the Lower Limit of a "Critical Bone Defect" in Open Diaphyseal Tibial Fractures.

    PubMed

    Haines, Nikkole M; Lack, William D; Seymour, Rachel B; Bosse, Michael J

    2016-05-01

    To determine healing outcomes of open diaphyseal tibial shaft fractures treated with reamed intramedullary nailing (IMN) with a bone gap of 10-50 mm on ≥50% of the cortical circumference and to better define a "critical bone defect" based on healing outcome. Retrospective cohort study. Forty patients, age 18-65, with open diaphyseal tibial fractures with a bone gap of 10-50 mm on ≥50% of the circumference as measured on standard anteroposterior and lateral postoperative radiographs treated with IMN. IMN of an open diaphyseal tibial fracture with a bone gap. Level-1 trauma center. Healing outcomes, union or nonunion. Forty patients were analyzed. Twenty-one (52.5%) went on to nonunion and nineteen (47.5%) achieved union. Radiographic apparent bone gap (RABG) and infection were the only 2 covariates predicting nonunion outcome (P = 0.046 for infection). The RABG was determined by measuring the bone gap on each cortex and averaging over 4 cortices. Fractures achieving union had a RABG of 12 ± 1 mm versus 20 ± 2 mm in those going on to nonunion (P < 0.01). This remained significant when patients with infection were removed. Receiver operator characteristic analysis demonstrated that RABG was predictive of outcome (area under the curve of 0.79). A RABG of 25 mm was the statistically optimal threshold for prediction of healing outcome. Patients with open diaphyseal tibial fractures treated with IMN and a <25 mm RABG have a reasonable probability of achieving union without additional intervention, whereas those with larger gaps have a higher probability of nonunion. Research investigating interventions for RABGs should use a predictive threshold for defining a critical bone defect that is associated with greater than 50% risk of nonunion without supplementary treatment. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  8. Ultrasonic sensing of GMAW: Laser/EMAT defect detection system. [Gas Metal Arc Welding (GMAW), Electromagnetic acoustic transducer (EMAT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, N.M.; Johnson, J.A.; Larsen, E.D.

    1992-01-01

    In-process ultrasonic sensing of welding allows detection of weld defects in real time. A noncontacting ultrasonic system is being developed to operate in a production environment. The principal components are a pulsed laser for ultrasound generation and an electromagnetic acoustic transducer (EMAT) for ultrasound reception. A PC-based data acquisition system determines the quality of the weld on a pass-by-pass basis. The laser/EMAT system interrogates the area in the weld volume where defects are most likely to occur. This area of interest is identified by computer calculations on a pass-by-pass basis using weld planning information provided by the off-line programmer. Themore » absence of a signal above the threshold level in the computer-calculated time interval indicates a disruption of the sound path by a defect. The ultrasonic sensor system then provides an input signal to the weld controller about the defect condition. 8 refs.« less

  9. Comparison between multislice and cone-beam computerized tomography in the volumetric assessment of cleft palate.

    PubMed

    Albuquerque, Marco Antonio; Gaia, Bruno Felipe; Cavalcanti, Marcelo Gusmão Paraíso

    2011-08-01

    The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. Copyright © 2011 Mosby, Inc. All rights reserved.

  10. EUV patterning improvement toward high-volume manufacturing

    NASA Astrophysics Data System (ADS)

    Kuwahara, Yuhei; Matsunaga, Koichi; Kawakami, Shinichiro; Nafus, Kathleen; Foubert, Philippe; Goethals, Anne-Marie

    2015-03-01

    Extreme ultraviolet lithography (EUVL) technology is a promising candidate for a semiconductor process for 18nm half pitch and beyond. So far, the studies of EUV for manufacturability have been focused on particular aspects. It still requires fine resolution, uniform and smooth patterns, and low defectivity, not only after lithography but also after the etch process. Tokyo Electron Limited and imec are continuously collaborating to improve manufacturing quality of the process of record (POR) on a CLEAN TRACKTM LITHIUS ProTMZ-EUV. This next generation coating/developing system has been upgraded with defectivity reduction enhancements which are applied along with TELTM best known methods. We have evaluated process defectivity post lithography and post etch. Apart from defectivity, FIRMTM rinse material and application compatibility with sub 18nm patterning is improved to prevent line pattern collapse and increase process window on next generation resist materials. This paper reports on the progress of defectivity and patterning performance optimization towards the NXE:3300 POR.

  11. Bottom-up photonic crystal approach with top-down defect and heterostructure fine-tuning.

    PubMed

    Ding, Tao; Song, Kai; Clays, Koen; Tung, Chen-Ho

    2010-03-16

    We combine the most efficient (chemical) approach toward three-dimensional photonic crystals with the most convenient (physical) technique for creating non-close-packed crystalline structures. Self-assembly of colloidal particles in artificial opals is followed by a carefully tuned plasma etching treatment. By covering the resulting top layer of more open structure with original dense opal, embedded defect layers and heterostructures can be conveniently designed for advanced photonic band gap and band edge engineering.

  12. Minimally Invasive, Organ-preserving Surgery for Large Submucosal Tumors in the Abdominal Esophagus.

    PubMed

    Kanehira, Eiji; Tanida, Takashi; Kamei, Aya; Takahashi, Kodai

    2017-06-01

    Surgical resection of submucosal tumors (SMTs) in the abdominal esophagus is not standardized. Enucleation may be a minimally invasive option, whereas its oncological validity is not very clear. Moreover, how to treat the esophageal wall defect after enucleation and necessity of additional antireflux procedure are also undetermined. In 13 patients with a SMT originating the abdominal esophagus laparoscopic enucleation was performed with preserving the integrity of submucosa. When the muscular layer defect was <4 cm it was directly closed by suturing, whereas it was left open in case the defect was larger. Fundoplication was added when the esophagus was dissected posteriorly or the myotomy was not closed. Tumors were resected en-bloc without rupture in all cases. In 5 patients myotomy was closed, whereas in the remaining 8 it was left open. In 11 patients fundoplication was added (Toupet in 5 and Dor in 6). The patients developed neither regurgitation nor stenosis postoperatively. The histopathologic findings revealed leiomyoma in 9 patients, whereas the other 4 were miscellaneous. The average tumor size was 5.5 cm (range, 2.8 to 8.8). Microscopically surgical margin was negative in all cases. Laparoscopic enucleation of SMTs in the abdominal esophagus seems to be safe, reproducible operation enabling preservation of function of the lower esophagus and esophagogastric junction. Even when the muscular defect is not approximated additional fundoplication can minimize the risk of postoperative reflux disease.

  13. Developing Open-Ended Questions for Surface Area and Volume of Beam

    ERIC Educational Resources Information Center

    Kurniawan, Henry; Putri, Ratu Ilma Indra; Hartono, Yusuf

    2018-01-01

    The purpose of this research was to show open-ended questions about surface area and beam volume which valid and practice, have potential effect. This research is research development which consists of two main phases: preliminary phase (preparation phase and problem design) and formative evaluation phase (evaluation and revision phases). The…

  14. Scientific Journal Publishing: Yearly Volume and Open Access Availability

    ERIC Educational Resources Information Center

    Bjork, Bo-Christer; Roos, Annikki; Lauri, Mari

    2009-01-01

    Introduction: We estimate the total yearly volume of peer-reviewed scientific journal articles published world-wide as well as the share of these articles available openly on the Web either directly or as copies in e-print repositories. Method: We rely on data from two commercial databases (ISI and Ulrich's Periodicals Directory) supplemented by…

  15. Structural responses of metallic glasses under neutron irradiation.

    PubMed

    Yang, L; Li, H Y; Wang, P W; Wu, S Y; Guo, G Q; Liao, B; Guo, Q L; Fan, X Q; Huang, P; Lou, H B; Guo, F M; Zeng, Q S; Sun, T; Ren, Y; Chen, L Y

    2017-12-01

    Seeking nuclear materials that possess a high resistance to particle irradiation damage is a long-standing issue. Permanent defects, induced by irradiation, are primary structural changes, the accumulation of which will lead to structural damage and performance degradation in crystalline materials served in nuclear plants. In this work, structural responses of neutron irradiation in metallic glasses (MGs) have been investigated by making a series of experimental measurements, coupled with simulations in ZrCu amorphous alloys. It is found that, compared with crystalline alloys, MGs have some specific structural responses to neutron irradiation. Although neutron irradiation can induce transient vacancy-like defects in MGs, they are fully annihilated after structural relaxation by rearrangement of free volumes. In addition, the rearrangement of free volumes depends strongly on constituent elements. In particular, the change in free volumes occurs around the Zr atoms, rather than the Cu centers. This implies that there is a feasible strategy for identifying glassy materials with high structural stability against neutron irradiation by tailoring the microstructures, the systems, or the compositions in alloys. This work will shed light on the development of materials with high irradiation resistance.

  16. Space charge induced surface stresses: implications in ceria and other ionic solids.

    PubMed

    Sheldon, Brian W; Shenoy, Vivek B

    2011-05-27

    Volume changes associated with point defects in space charge layers can produce strains that substantially alter thermodynamic equilibrium near surfaces in ionic solids. For example, near-surface compressive stresses exceeding -10 GPa are predicted for ceria. The magnitude of this effect is consistent with anomalous lattice parameter increases that occur in ceria nanoparticles. These stresses should significantly alter defect concentrations and key transport properties in a wide range of materials (e.g., ceria electrolytes in fuel cells). © 2011 American Physical Society

  17. Lethal Progressive Thoracic Insufficiency in a Neonate Due to Jarcho Levin Syndrome

    PubMed Central

    Bhutia, Euden; Maria, Arti; Verma, Arushi; Sethi, Sidharth Kumar

    2014-01-01

    A rare case of Jarcho Levin syndrome (JLS) presenting as a lethal progressive respiratory insufficiency in early neonatal period is reported. The neonate had classical features of this syndrome including vertebral segmentation defects, typical costo-vertebral fusion defects and scoliosis resulting in small thoracic volume and limited chest expansion; all consistent with a clinical diagnosis of JLS with thoracic insufficiency. In addition, our case had a rare association of dextrocardia and acyanotic congenital heart disease. PMID:24741543

  18. 21ST International Symposium on Rarefied Gas Dynamics, Marseille (France) 26-31 July 1998. Book of Abstracts, Volume I: Oral Sessions.

    DTIC Science & Technology

    1998-07-30

    properties of gases, there are some major ite Gases, Academic Press, New York (1969). defects common to gas kinetic treatments. In hy- (1988). drodynamic...the incondensable gas are Recently, serious defects in classical gasdynamics comparable. in describing the behavior of a gas in the contin- We use the...Transition of Hypersonic, Chemically Reacting Boundary Layers J. Perraud, D. Arnal, F. Thivet ONERA CERT, DMAE , Toulouse, France 1 Introduction of

  19. Defense Small Business Innovation Research Program (SBIR). Volume 3. Air Force Abstracts of Phase 1 Awards

    DTIC Science & Technology

    1990-01-01

    THERE WILL BE A CONTINUING NEED FOR A SENSITIVE, RAPID, AND ECONOMICAL TESTING PROCEDURE CAPABLE OF DETECTING DEFECTS AND PROVIDING FEEDBACK FOR QUALITY...SOLUTIONS. THE DKF METHOD PROVIDES OPTIMAL OR NEAR-OPTIMAL ACCURACY, REDUCE PROCESSING BURDEN, AND IMPROVE FAULT TOLERANCE. THE DKF/MMAE ( DMAE ) TECHNIQUES...DEVICES FOR B-SiC IS TO BE ABLE TO CONSISTENTLY PRODUCE INTRINSIC FILMS WITH VERY LOW DEFECTS AND TO DEVELOP SCHOTTKY AND OHMIC CONTACT MATERIALS THAT WILL

  20. Electronic and structural properties of vacancies and hydrogen adsorbates on trilayer graphene

    NASA Astrophysics Data System (ADS)

    Menezes, Marcos G.; Capaz, Rodrigo B.

    2015-08-01

    Using ab initio calculations, we study the electronic and structural properties of vacancies and hydrogen adsorbates on trilayer graphene. Those defects are found to share similar low-energy electronic features, since they both remove a pz electron from the honeycomb lattice and induce a defect level near the Fermi energy. However, a vacancy also leaves unpaired σ electrons on the lattice, which lead to important structural differences and also contribute to magnetism. We explore both ABA and ABC stackings and compare properties such as formation energies, magnetic moments, spin density and the local density of states (LDOS) of the defect levels. These properties show a strong sensitivity to the layer in which the defect is placed and smaller sensitivities to sublattice placing and stacking type. Finally, for the ABC trilayer, we also study how these states behave in the presence of an external field, which opens a tunable gap in the band structure of the non-defective system. The pz defect states show a strong hybridization with band states as the field increases, with reduction and eventually loss of magnetization, and a non-magnetic, midgap-like state is found when the defect is at the middle layer.

  1. Electronic and Structural Properties of Vacancies and Hydrogen Adsorbates on Trilayer Graphene

    NASA Astrophysics Data System (ADS)

    Menezes, Marcos; Capaz, Rodrigo

    2015-03-01

    Using ab initio calculations, we study the electronic and structural properties of vacancies and hydrogen adsorbates on trilayer graphene. Those defects are found to share similar low-energy electronic features, since they both remove a pz electron from the honeycomb lattice and induce a defect level near the Fermi energy. However, a vacancy also leaves unpaired σ electrons on the lattice, which lead to important structural differences and also contribute to magnetism. We explore both ABA and ABC stackings and compare properties such as formation energies, magnetic moments, spin density and the local density of states (LDOS) of the defect levels. These properties show a strong sensitivity to the layer in which the defect is placed and smaller sensitivities to sublattice placing and stacking type. Finally, for the ABC trilayer, we also study how these states behave in the presence of an external electrical field, which opens a tunable gap in the band structure of the non-defective system. The pz defect states show a strong hybridization with band states as the field increases, with reduction and eventually loss of magnetization, and a non-magnetic, midgap-like state is found when the defect is at the middle layer.

  2. Local and transient nanoscale strain mapping during in situ deformation

    DOE PAGES

    Gammer, C.; Kacher, J.; Czarnik, C.; ...

    2016-08-26

    The mobility of defects such as dislocations controls the mechanical properties of metals. This mobility is determined both by the characteristics of the defect and the material, as well as the local stress and strain applied to the defect. Therefore, the knowledge of the stress and strain during deformation at the scale of defects is important for understanding fundamental deformation mechanisms. In this paper, we demonstrate a method of measuring local stresses and strains during continuous in situ deformation with a resolution of a few nanometers using nanodiffraction strain mapping. Finally, our results demonstrate how large multidimensional data sets capturedmore » with high speed electron detectors can be analyzed in multiple ways after an in situ TEM experiment, opening the door for true multimodal analysis from a single electron scattering experiment.« less

  3. Structural study of some divalent aluminoborate glasses using ultrasonic and positron annihilation techniques

    NASA Astrophysics Data System (ADS)

    Saddeek, Yasser B.; Mohamed, Hamdy F. M.; Azooz, Moenis A.

    2004-07-01

    Positron annihilation lifetime (PAL), ultrasonic techniques, and differential thermal analysis (DTA) were performed to study the structure of some aluminoborate glasses. The basic compositions of these glasses are 50 B2O3 + 10 Al2O3 + 40 RO (wt%), where RO is the divalent oxide (MgO, CaO, SrO, and CdO). The ultrasonic data show that the rigidity increases from MgO to CaO then decrease at SrO and again increases at CdO. The glass transition temperature (determined from DTA) decreases from MgO to SrO then increases at CdO. The trend of the thermal properties was attributed to thermal stability. The experimental data are correlated with the internal glass structure and its connectivity. The PAL data show that an inversely correlation between the relative fractional of the open hole volume and the density of the samples. Also, there is a good correlation between the ortho-positronium (o-Ps) lifetime (open hole volume size) and the bulk modulus of the samples (determined from ultrasonic technique). The open volume hole size distribution for the samples shows that the open volume holes expand in size for CaO, SrO, MgO, and CdO, respectively with their distribution function moving to higher volume size.

  4. Observer POD for radiographic testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanzler, Daniel, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de; Ewert, Uwe, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de; Müller, Christina, E-mail: daniel.kanzler@bam.de, E-mail: uwe.ewert@bam.de, E-mail: christina.mueller@bam.de

    2015-03-31

    The radiographic testing (RT) is a non-destructive testing (NDT) method capable of finding volumetric and open planar defects depending on their orientation. The radiographic contrast is higher for larger penetrated length of the defect in a component. Even though, the detectability of defects does not only depend on the contrast, but also on the noise, the defect area and the geometry of the defect. The currently applied Probability of Detection (POD) approach uses a detection threshold that is only based on a constant noise level or on a constant contrast threshold. This does not reflect accurately the results of evaluationsmore » by human observers. A new approach is introduced, using the widely applied POD evaluation and additionally a detection threshold depending on the lateral area and shape of the indication. This work shows the process of calculating the POD curves with simulated data by the modeling software aRTist and with artificial reference data of different defect types, such as ASTM E 476 EPS plates, flat bottom holes and notches. Additional experiments with different operators confirm that the depth of a defect, the lateral area and shape of its indication contribute with different weight to the detectability of the defect if evaluated by human operators on monitors.« less

  5. When intracellular logistics fails--genetic defects in membrane trafficking.

    PubMed

    Olkkonen, Vesa M; Ikonen, Elina

    2006-12-15

    The number of human genetic disorders shown to be due to defects in membrane trafficking has greatly increased during the past five years. Defects have been identified in components involved in sorting of cargo into transport carriers, vesicle budding and scission, movement of vesicles along cytoskeletal tracks, as well as in vesicle tethering, docking and fusion at the target membrane. The nervous system is extremely sensitive to such disturbances of the membrane trafficking machinery, and the majority of these disorders display neurological defects--particularly diseases affecting the motility of transport carriers along cytoskeletal tracks. In several disorders, defects in a component that represents a fundamental part of the trafficking machinery fail to cause global transport defects but result in symptoms limited to specific cell types and transport events; this apparently reflects the redundancy of the transport apparatus. In groups of closely related diseases such as Hermansky-Pudlak and Griscelli syndromes, identification of the underlying gene defects has revealed groups of genes in which mutations lead to similar phenotypic consequences. New functionally linked trafficking components and regulatory mechanisms have thus been discovered. Studies of the gene defects in trafficking disorders therefore not only open avenues for new therapeutic approaches but also significantly contribute to our knowledge of the fundamental mechanisms of intracellular membrane transport.

  6. Laparoscopic bridging vs. anatomic open reconstruction for midline abdominal hernia mesh repair [LABOR]: single-blinded, multicenter, randomized, controlled trial on long-term functional results.

    PubMed

    Stabilini, Cesare; Bracale, Umberto; Pignata, Giusto; Frascio, Marco; Casaccia, Marco; Pelosi, Paolo; Signori, Alessio; Testa, Tommaso; Rosa, Gian Marco; Morelli, Nicola; Fornaro, Rosario; Palombo, Denise; Perotti, Serena; Bruno, Maria Santina; Imperatore, Mikaela; Righetti, Carolina; Pezzato, Stefano; Lazzara, Fabrizio; Gianetta, Ezio

    2013-10-28

    Re-approximation of the rectal muscles along the midline is recommended by some groups as a rule for incisional and ventral hernia repairs. The introduction of laparoscopic repair has generated a debate because it is not aimed at restoring abdominal wall integrity but instead aims just to bridge the defect. Whether restoration of the abdominal integrity has a real impact on patient mobility is questionable, and the available literature provides no definitive answer. The present study aims to compare the functional results of laparoscopic bridging with those of re-approximation of the rectal muscle in the midline as a mesh repair for ventral and incisional abdominal defect through an "open" access. We hypothesized that, for the type of defect suitable for a laparoscopic bridging, the effect of an anatomical reconstruction is near negligible, thus not a fixed rule. The LABOR trial is a multicenter, prospective, two-arm, single-blinded, randomized trial. Patients of more than 60 years of age with a defect of less than 10 cm at its greatest diameter will be randomly submitted to open Rives or laparoscopic defect repair. All the participating patients will have a preoperative evaluation of their abdominal wall strength and mobility along with volumetry, respiratory function test, intraabdominal pressure and quality of life assessment.The primary outcome will be the difference in abdominal wall strength as measured by a double leg-lowering test performed at 12 months postoperatively. The secondary outcomes will be the rate of recurrence and changes in baseline abdominal mobility, respiratory function tests, intraabdominal pressure, CT volumetry and quality of life at 6 and 12 months postoperatively. The study will help to define the most suitable treatment for small-medium incisional and primary hernias in patients older than 60 years. Given a similar mid-term recurrence rate in both groups, if the trial shows no differences among treatments (acceptance of the null-hypothesis), then the choice of whether to submit a patient to one intervention will be made on the basis of cost and the surgeon's experience. Current Controlled Trials ISRCTN93729016.

  7. A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber

    Treesearch

    Tai-Hoon Cho; Richard W. Conners; Philip A. Araman

    1990-01-01

    A sawmill cuts logs into lumber and sells this lumber to secondary remanufacturers. The price a sawmiller can charge for a volume of lumber depends on its grade. For a number of species the price of a given volume of material can double in going from one grade to the next higher grade. While the grade of a board largely depends on the distribution of defects on the...

  8. Microbubble gas volume: A unifying dose parameter in blood-brain barrier opening by focused ultrasound.

    PubMed

    Song, Kang-Ho; Fan, Alexander C; Hinkle, Joshua J; Newman, Joshua; Borden, Mark A; Harvey, Brandon K

    2017-01-01

    Focused ultrasound with microbubbles is being developed to transiently, locally and noninvasively open the blood-brain barrier (BBB) for improved pharmaceutical delivery. Prior work has demonstrated that, for a given concentration dose, microbubble size affects both the intravascular circulation persistence and extent of BBB opening. When matched to gas volume dose, however, the circulation half-life was found to be independent of microbubble size. In order to determine whether this holds true for BBB opening as well, we independently measured the effects of microbubble size (2 vs. 6 µm diameter) and concentration, covering a range of overlapping gas volume doses (1-40 µL/kg). We first demonstrated precise targeting and a linear dose-response of Evans Blue dye extravasation to the rat striatum for a set of constant microbubble and ultrasound parameters. We found that dye extravasation increased linearly with gas volume dose, with data points from both microbubble sizes collapsing to a single line. A linear trend was observed for both the initial sonication (R 2 =0.90) and a second sonication on the contralateral side (R 2 =0.68). Based on these results, we conclude that microbubble gas volume dose, not size, determines the extent of BBB opening by focused ultrasound (1 MHz, ~0.5 MPa at the focus). This result may simplify planning for focused ultrasound treatments by constraining the protocol to a single microbubble parameter - gas volume dose - which gives equivalent results for varying size distributions. Finally, using optimal parameters determined for Evan Blue, we demonstrated gene delivery and expression using a viral vector, dsAAV1-CMV-EGFP, one week after BBB disruption, which allowed us to qualitatively evaluate neuronal health.

  9. Defect tolerance and the effect of structural inhomogeneity in plasmonic DNA-nanoparticle superlattices

    DOE PAGES

    Ross, Michael B.; Ku, Jessie C.; Blaber, Martin G.; ...

    2015-08-03

    Bottom-up assemblies of plasmonic nanoparticles exhibit unique optical effects such as tunable reflection, optical cavity modes, and tunable photonic resonances. In this paper, we compare detailed simulations with experiment to explore the effect of structural inhomogeneity on the optical response in DNA-gold nanoparticle superlattices. In particular, we explore the effect of background environment, nanoparticle polydispersity (>10%), and variation in nanoparticle placement (~5%). At volume fractions less than 20% Au, the optical response is insensitive to particle size, defects, and inhomogeneity in the superlattice. At elevated volume fractions (20% and 25%), structures incorporating different sized nanoparticles (10-, 20-, and 40-nm diameter)more » each exhibit distinct far-field extinction and near-field properties. These optical properties are most pronounced in lattices with larger particles, which at fixed volume fraction have greater plasmonic coupling than those with smaller particles. Moreover, the incorporation of experimentally informed inhomogeneity leads to variation in far-field extinction and inconsistent electric-field intensities throughout the lattice, demonstrating that volume fraction is not sufficient to describe the optical properties of such structures. Finally, these data have important implications for understanding the role of particle and lattice inhomogeneity in determining the properties of plasmonic nanoparticle lattices with deliberately designed optical properties.« less

  10. Outcome of patients undergoing open heart surgery at the Uganda heart institute, Mulago hospital complex.

    PubMed

    Aliku, Twalib O; Lubega, Sulaiman; Lwabi, Peter; Oketcho, Michael; Omagino, John O; Mwambu, Tom

    2014-12-01

    Heart disease is a disabling condition and necessary surgical intervention is often lacking in many developing countries. Training of the superspecialties abroad is largely limited to observation with little or no opportunity for hands on experience. An approach in which open heart surgeries are conducted locally by visiting teams enabling skills transfer to the local team and helps build to build capacity has been adopted at the Uganda Heart Institute (UHI). We reviewed the progress of open heart surgery at the UHI and evaluated the postoperative outcomes and challenges faced in conducting open heart surgery in a developing country. Medical records of patients undergoing open heart surgery at the UHI from October 2007 to June 2012 were reviewed. A total of 124 patients underwent open heart surgery during the study period. The commonest conditions were: venticular septal defects (VSDs) 34.7% (43/124), Atrial septal defects (ASDs) 34.7% (43/124) and tetralogy of fallot (TOF) in 10.5% (13/124). Non governmental organizations (NGOs) funded 96.8% (120/124) of the operations, and in only 4 patients (3.2%) families paid for the surgeries. There was increasing complexity in cases operated upon from predominantly ASDs and VSDs at the beginning to more complex cases like TOFs and TAPVR. The local team independently operated 19 patients (15.3%). Postoperative morbidity was low with arrhythmias, left ventricular dysfunction and re-operations being the commonest seen. Post operative sepsis occurred in only 2 cases (1.6%). The overall mortality rate was 3.2. Open heart surgery though expensive is feasible in a developing country. With increased direct funding from governments and local charities to support open heart surgeries, more cardiac patients access surgical treatment locally.

  11. Delayed Implants Outcome in Maxillary Molar Region.

    PubMed

    Crespi, Roberto; Capparè, Paolo; Crespi, Giovanni; Gastaldi, Giorgio; Gherlone, Enrico F

    2017-04-01

    The aim of the present study was to assess bone volume changes in maxillary molar regions after delayed implants placement. Patients presented large bone defects after tooth extractions. Reactive soft tissue was left into the defects. No grafts were used. Cone beam computed tomography (CBCT) scans were performed before tooth extractions, at implant placement (at 3 months from extraction) and 3 years after implant placement, bone volume measurements were assessed. Bucco-lingual width showed a statistically significant decrease (p = .013) at implant placement, 3 months after extraction. Moreover, a statistically significant increase (p < .01) was measured 3 years after implant placement. No statistically significant differences (p > .05) were found between baseline values (before extraction) and at 3 years from implant placement. Vertical dimension showed no statistically significant differences (p > .05) at implant placement, 3 months after extraction. Statistically significant differences (p < .0001) were found between baseline values (before extraction) and at 3 months from implant placement as well as between implant placement values and 3 years later. CT scans presented successful outcome of delayed implants placed in large bone defects at 3-year follow-up. © 2016 Wiley Periodicals, Inc.

  12. Is bone transplantation the gold standard for repair of alveolar bone defects?

    PubMed

    Raposo-Amaral, Cassio Eduardo; Bueno, Daniela Franco; Almeida, Ana Beatriz; Jorgetti, Vanda; Costa, Cristiane Cabral; Gouveia, Cecília Helena; Vulcano, Luiz Carlos; Fanganiello, Roberto D; Passos-Bueno, Maria Rita; Alonso, Nivaldo

    2014-01-01

    New strategies to fulfill craniofacial bone defects have gained attention in recent years due to the morbidity of autologous bone graft harvesting. We aimed to evaluate the in vivo efficacy of bone tissue engineering strategy using mesenchymal stem cells associated with two matrices (bovine bone mineral and α-tricalcium phosphate), compared to an autologous bone transfer. A total of 28 adult, male, non-immunosuppressed Wistar rats underwent a critical-sized osseous defect of 5 mm diameter in the alveolar region. Animals were divided into five groups. Group 1 (n = 7) defects were repaired with autogenous bone grafts; Group 2 (n = 5) defects were repaired with bovine bone mineral free of cells; Group 3 (n = 5) defects were repaired with bovine bone mineral loaded with mesenchymal stem cells; Group 4 (n = 5) defects were repaired with α-tricalcium phosphate free of cells; and Group 5 (n = 6) defects were repaired with α-tricalcium phosphate loaded with mesenchymal stem cells. Groups 2-5 were compared to Group 1, the reference group. Healing response was evaluated by histomorphometry and computerized tomography. Histomorphometrically, Group 1 showed 60.27% ± 16.13% of bone in the defect. Groups 2 and 3 showed 23.02% ± 8.6% (p = 0.01) and 38.35% ± 19.59% (p = 0.06) of bone in the defect, respectively. Groups 4 and 5 showed 51.48% ± 11.7% (p = 0.30) and 61.80% ± 2.14% (p = 0.88) of bone in the defect, respectively. Animals whose bone defects were repaired with α-tricalcium phosphate and mesenchymal stem cells presented the highest bone volume filling the defects; both were not statistically different from autogenous bone.

  13. Automated reticle inspection data analysis for wafer fabs

    NASA Astrophysics Data System (ADS)

    Summers, Derek; Chen, Gong; Reese, Bryan; Hutchinson, Trent; Liesching, Marcus; Ying, Hai; Dover, Russell

    2009-04-01

    To minimize potential wafer yield loss due to mask defects, most wafer fabs implement some form of reticle inspection system to monitor photomask quality in high-volume wafer manufacturing environments. Traditionally, experienced operators review reticle defects found by an inspection tool and then manually classify each defect as 'pass, warn, or fail' based on its size and location. However, in the event reticle defects are suspected of causing repeating wafer defects on a completed wafer, potential defects on all associated reticles must be manually searched on a layer-by-layer basis in an effort to identify the reticle responsible for the wafer yield loss. This 'problem reticle' search process is a very tedious and time-consuming task and may cause extended manufacturing line-down situations. Often times, Process Engineers and other team members need to manually investigate several reticle inspection reports to determine if yield loss can be tied to a specific layer. Because of the very nature of this detailed work, calculation errors may occur resulting in an incorrect root cause analysis effort. These delays waste valuable resources that could be spent working on other more productive activities. This paper examines an automated software solution for converting KLA-Tencor reticle inspection defect maps into a format compatible with KLA-Tencor's Klarity Defect(R) data analysis database. The objective is to use the graphical charting capabilities of Klarity Defect to reveal a clearer understanding of defect trends for individual reticle layers or entire mask sets. Automated analysis features include reticle defect count trend analysis and potentially stacking reticle defect maps for signature analysis against wafer inspection defect data. Other possible benefits include optimizing reticle inspection sample plans in an effort to support "lean manufacturing" initiatives for wafer fabs.

  14. Automated reticle inspection data analysis for wafer fabs

    NASA Astrophysics Data System (ADS)

    Summers, Derek; Chen, Gong; Reese, Bryan; Hutchinson, Trent; Liesching, Marcus; Ying, Hai; Dover, Russell

    2009-03-01

    To minimize potential wafer yield loss due to mask defects, most wafer fabs implement some form of reticle inspection system to monitor photomask quality in high-volume wafer manufacturing environments. Traditionally, experienced operators review reticle defects found by an inspection tool and then manually classify each defect as 'pass, warn, or fail' based on its size and location. However, in the event reticle defects are suspected of causing repeating wafer defects on a completed wafer, potential defects on all associated reticles must be manually searched on a layer-by-layer basis in an effort to identify the reticle responsible for the wafer yield loss. This 'problem reticle' search process is a very tedious and time-consuming task and may cause extended manufacturing line-down situations. Often times, Process Engineers and other team members need to manually investigate several reticle inspection reports to determine if yield loss can be tied to a specific layer. Because of the very nature of this detailed work, calculation errors may occur resulting in an incorrect root cause analysis effort. These delays waste valuable resources that could be spent working on other more productive activities. This paper examines an automated software solution for converting KLA-Tencor reticle inspection defect maps into a format compatible with KLA-Tencor's Klarity DefectTM data analysis database. The objective is to use the graphical charting capabilities of Klarity Defect to reveal a clearer understanding of defect trends for individual reticle layers or entire mask sets. Automated analysis features include reticle defect count trend analysis and potentially stacking reticle defect maps for signature analysis against wafer inspection defect data. Other possible benefits include optimizing reticle inspection sample plans in an effort to support "lean manufacturing" initiatives for wafer fabs.

  15. Online aptitude automatic surface quality inspection system for hot rolled strips steel

    NASA Astrophysics Data System (ADS)

    Lin, Jin; Xie, Zhi-jiang; Wang, Xue; Sun, Nan-Nan

    2005-12-01

    Defects on the surface of hot rolled steel strips are main factors to evaluate quality of steel strips, an improved image recognition algorithm are used to extract the feature of Defects on the surface of steel strips. Base on the Machine vision and Artificial Neural Networks, establish a defect recognition method to select defect on the surface of steel strips. Base on these research. A surface inspection system and advanced algorithms for image processing to hot rolled strips is developed. Preparing two different fashion to lighting, adopting line blast vidicon of CCD on the surface steel strips on-line. Opening up capacity-diagnose-system with level the surface of steel strips on line, toward the above and undersurface of steel strips with ferric oxide, injure, stamp etc of defects on the surface to analyze and estimate. Miscarriage of justice and alternate of justice rate not preponderate over 5%.Geting hold of applications on some big enterprises of steel at home. Experiment proved that this measure is feasible and effective.

  16. Photochemical Creation of Fluorescent Quantum Defects in Semiconducting Carbon Nanotube Hosts.

    PubMed

    Wu, Xiaojian; Kim, Mijin; Kwon, Hyejin; Wang, YuHuang

    2018-01-15

    Quantum defects are an emerging class of synthetic single-photon emitters that hold vast potential for near-infrared imaging, chemical sensing, materials engineering, and quantum information processing. Herein, we show that it is possible to optically direct the synthetic creation of molecularly tunable fluorescent quantum defects in semiconducting single-walled carbon nanotube hosts through photochemical reactions. By exciting the host semiconductor with light that resonates with its electronic transition, we find that halide-containing aryl groups can covalently bond to the sp 2 carbon lattice. The introduced quantum defects generate bright photoluminescence that allows tracking of the reaction progress in situ. We show that the reaction is independent of temperature but correlates strongly with the photon energy used to drive the reaction, suggesting a photochemical mechanism rather than photothermal effects. This type of photochemical reactions opens the possibility to control the synthesis of fluorescent quantum defects using light and may enable lithographic patterning of quantum emitters with electronic and molecular precision. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Non-contact inline monitoring of thermoplastic CFRP tape quality using air-coupled ultrasound

    NASA Astrophysics Data System (ADS)

    Essig, W.; Fey, P.; Meiler, S.; Kreutzbruck, M.

    2017-02-01

    Beginning with the aerospace industry, fiber reinforced plastics have spread towards many applications such as automotive, civil engineering as well as sports and leisure articles. Their superior strength and stiffness to mass ratio made them the number one material for achieving high performance. Especially continuous fiber reinforced plastics allow for the construction of structures which are custom tailored to their mechanical loads by adjusting the paths of the fibers to the loading direction. The two main constituents of CFRP are carbon fibers and matrix. Two possibilities for matrix material exist: thermosetting and thermoplastic matrix. While thermosetting matrix may yield better properties with respect to thermal loads, thermoplasticity opens a wide range of applications due to weldability, shapeability, and compatibility to e.g. injection molded thermoplastic materials. Thin (0.1 mm) thermoplastic continuous fiber CFRP tapes with a width of 100 mm were examined using air-coupled ultrasound. Transducers were arranged in reflection as well as transmission setup. By slanted incidence of the ultrasound on the tape surface, guided waves were excited in the material in fiber direction and perpendicular to the fiber direction. Artificial defects - fiber cuts, matrix cuts, circular holes, low velocity impacts from tool drop, and sharp bends - were produced. Experiments on a stationary tape showed good detectability of all artificial defects by guided waves. Also the effects of variation in material properties, fiber volume content and fiber matrix adhesion being the most relevant, on guided wave propagation were examined, to allow for quality assessment. Guided wave measurements were supported by destructive analysis. Also an apparatus containing one endless loop of CFRP tape was constructed and built to simulate inline testing of CFRP tapes, as it would be employed in a CFRP tape production environment or at a CFRP tape processing facility. The influences of tape conveying speed on detectability of artificial defects as well as material properties were elaborated and recommendations for implementation in production scale inline monitoring are given.

  18. Extended resection of the trachea in a patient with cicatricial tracheal stenosis after tracheostomy complicated with esophageal-tracheal fistula and extensive defect of the frontal tracheal wall

    PubMed Central

    Khudaybergenov, Shukhrat; Abdusalomov, Sodiqjon; Amanov, Bakhrom

    2017-01-01

    We present a case of one-stage radical surgical treatment of a 24-year-old female patient with cicatricial granulating tracheal stenosis after tracheostomy complicated by esophageal-tracheal fistula and an extensive defect of the anterior wall of the trachea after numerous unsuccessful attempts to correct the narrowing of the trachea and eliminate the fistula by endoscopic and open surgical techniques. The patient underwent extended tracheal resection with end-to-end anastomosis with liquidation of the esophageal-tracheal fistula and elimination of the defect of the anterior wall of the trachea by cervical access. PMID:28515752

  19. Extended resection of the trachea in a patient with cicatricial tracheal stenosis after tracheostomy complicated with esophageal-tracheal fistula and extensive defect of the frontal tracheal wall.

    PubMed

    Khudaybergenov, Shukhrat; Eshonkhodjaev, Otabek; Abdusalomov, Sodiqjon; Amanov, Bakhrom

    2017-03-01

    We present a case of one-stage radical surgical treatment of a 24-year-old female patient with cicatricial granulating tracheal stenosis after tracheostomy complicated by esophageal-tracheal fistula and an extensive defect of the anterior wall of the trachea after numerous unsuccessful attempts to correct the narrowing of the trachea and eliminate the fistula by endoscopic and open surgical techniques. The patient underwent extended tracheal resection with end-to-end anastomosis with liquidation of the esophageal-tracheal fistula and elimination of the defect of the anterior wall of the trachea by cervical access.

  20. Hydrogel Delivery of Mesenchymal Stem Cell–Expressing Bone Morphogenetic Protein-2 Enhances Bone Defect Repair

    PubMed Central

    Hsiao, Hui-Yi; Yang, Shu-Rui; Brey, Eric M.; Chu, I-Ming

    2016-01-01

    Background: The application of bone tissue engineering for repairing bone defects has gradually shown some satisfactory progress. One of the concerns raising scientific attention is the poor supply of growth factors. A number of growth factor delivery approaches have been developed for promoting bone formation. However, there is no systematic comparison of those approaches on efficiency of neobone formation. In this study, the approaches using periosteum, direct supply of growth factors, or gene transfection of growth factors were evaluated to determine the osteogenic capacity on the repair of bone defect. Methods: In total, 42 male 21-week-old Sprague-Dawley rats weighing 250 to 400 g were used as the bone defect model to evaluate the bone repair efficiency. Various tissue engineered constructs of poly(ethylene glycol)-poly(l-lactic acid) (PEG-PLLA) copolymer hydrogel with periosteum, with external supply of bone morphogenetic protein-2 (BMP2), or with BMP2-transfected bone marrow–derived mesenchymal stem cells (BMMSCs) were filled in a 7-mm bone defect region. Animals were euthanized at 3 months, and the hydrogel constructs were harvested. The evaluation with histological staining and radiography analysis were performed for the volume of new bone formation. Results: The PEG-PLLA scaffold with BMMSCs promotes bone regeneration with the addition of periosteum. The group with BMP2-transfected BMMSCs demonstrated the largest volume of new bone among all the testing groups. Conclusions: Altogether, the results of this study provide the evidence that the combination of PEG-PLLA hydrogels with BMMSCs and sustained delivery of BMP2 resulted in the maximal bone regeneration. PMID:27622106

  1. Myocardial Perfusion Pattern for Stratification of Ischemic Mitral Regurgitation Response to Percutaneous Coronary Intervention

    PubMed Central

    Goyal, Parag; Kim, Jiwon; Feher, Attila; Ma, Claudia L.; Gurevich, Sergey; Veal, David R.; Szulc, Massimiliano; Wong, Franklin J.; Ratcliffe, Mark B.; Levine, Robert A.; Devereux, Richard B.; Weinsaft, Jonathan W.

    2015-01-01

    Objective Ischemic mitral regurgitation (MR) is common, but its response to percutaneous coronary intervention (PCI) is poorly understood. This study tested utility of myocardial perfusion imaging (MPI) for stratification of MR response to PCI. Methods MPI and echo were performed among patients undergoing PCI. MPI was used to assess stress/rest myocardial perfusion. MR was assessed via echo (performed pre- and post-PCI). Results 317 patients with abnormal myocardial perfusion on MPI underwent echo 25±39 days prior to PCI. MR was present in 52%, among whom 24% had advanced (≥moderate) MR. MR was associated with LV chamber dilation on MPI and echo (both p<0.001). Magnitude of global LV perfusion deficits increased in relation to MR severity (p<0.01). Perfusion differences were greatest for global summed rest scores, which were 1.6-fold higher among patients with advanced MR vs. those with mild MR (p=0.004), and 2.4-fold higher vs. those without MR (p<0.001). In multivariate analysis, advanced MR was associated with fixed perfusion defect size on MPI (OR 1.16 per segment [CI 1.002–1.34], p=0.046) independent of LV volume (OR 1.10 per 10ml [CI 1.04–1.17], p=0.002). Follow-up via echo (1.0±0.6 years) demonstrated MR to decrease (≥1 grade) in 31% of patients, and increase in 12%. Patients with increased MR after PCI had more severe inferior perfusion defects on baseline MPI (p=0.028), whereas defects in other distributions and LV volumes were similar (p=NS). Conclusions Extent and distribution of SPECT-evidenced myocardial perfusion defects impacts MR response to revascularization. Increased magnitude of inferior fixed perfusion defects predicts post-PCI progression of MR. PMID:26049923

  2. Quantitative analysis of hyperpolarized 129Xe ventilation imaging in healthy volunteers and subjects with chronic obstructive pulmonary disease

    PubMed Central

    Virgincar, Rohan S.; Cleveland, Zackary I.; Kaushik, S. Sivaram; Freeman, Matthew S.; Nouls, John; Cofer, Gary P.; Martinez-Jimenez, Santiago; He, Mu; Kraft, Monica; Wolber, Jan; McAdams, H. Page; Driehuys, Bastiaan

    2013-01-01

    In this study, hyperpolarized (HP) 129Xe MR ventilation and 1H anatomical images were obtained from 3 subject groups: young healthy volunteers (HV), subjects with chronic obstructive pulmonary disease (COPD), and age-matched control subjects (AMC). Ventilation images were quantified by 2 methods: an expert reader-based ventilation defect score percentage (VDS%) and a semi-automatic segmentation-based ventilation defect percentage (VDP). Reader-based values were assigned by two experienced radiologists and resolved by consensus. In the semi-automatic analysis, 1H anatomical images and 129Xe ventilation images were both segmented following registration, to obtain the thoracic cavity volume (TCV) and ventilated volume (VV), respectively, which were then expressed as a ratio to obtain the VDP. Ventilation images were also characterized by generating signal intensity histograms from voxels within the TCV, and heterogeneity was analyzed using the coefficient of variation (CV). The reader-based VDS% correlated strongly with the semi-automatically generated VDP (r = 0.97, p < 0.0001), and with CV (r = 0.82, p < 0.0001). Both 129Xe ventilation defect scoring metrics readily separated the 3 groups from one another and correlated significantly with FEV1 (VDS%: r = -0.78, p = 0.0002; VDP: r = -0.79, p = 0.0003; CV: r = -0.66, p = 0.0059) and other pulmonary function tests. In the healthy subject groups (HV and AMC), the prevalence of ventilation defects also increased with age (VDS%: r = 0.61, p = 0.0002; VDP: r = 0.63, p = 0.0002). Moreover, ventilation histograms and their associated CVs distinguished between COPD subjects with similar ventilation defect scores but visibly different ventilation patterns. PMID:23065808

  3. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    NASA Astrophysics Data System (ADS)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between clinically acquired SPECT perfusion and specific ventilation from 4D CT. Results suggest high correlation between methods within the sub-population of lung cancer patients with malignant airway stenosis.

  4. [Interpretation and use of routine pulmonary function tests: Spirometry, static lung volumes, lung diffusion, arterial blood gas, methacholine challenge test and 6-minute walk test].

    PubMed

    Bokov, P; Delclaux, C

    2016-02-01

    Resting pulmonary function tests (PFT) include the assessment of ventilatory capacity: spirometry (forced expiratory flows and mobilisable volumes) and static volume assessment, notably using body plethysmography. Spirometry allows the potential definition of obstructive defect, while static volume assessment allows the potential definition of restrictive defect (decrease in total lung capacity) and thoracic hyperinflation (increase in static volumes). It must be kept in mind that this evaluation is incomplete and that an assessment of ventilatory demand is often warranted, especially when facing dyspnoea: evaluation of arterial blood gas (searching for respiratory insufficiency) and measurement of the transfer coefficient of the lung, allowing with the measurement of alveolar volume to calculate the diffusing capacity of the lung for CO (DLCO: assessment of alveolar-capillary wall and capillary blood volume). All these pulmonary function tests have been the subject of an Americano-European Task force (standardisation of lung function testing) published in 2005, and translated in French in 2007. Interpretative strategies for lung function tests have been recommended, which define abnormal lung function tests using the 5th and 95th percentiles of predicted values (lower and upper limits of normal values). Thus, these recommendations need to be implemented in all pulmonary function test units. A methacholine challenge test will only be performed in the presence of an intermediate pre-test probability for asthma (diagnostic uncertainty), which is an infrequent setting. The most convenient exertional test is the 6-minute walk test that allows the assessment of walking performance, the search for arterial desaturation and the quantification of dyspnoea complaint. Copyright © 2015 Société nationale française de médecine interne (SNFMI). Published by Elsevier SAS. All rights reserved.

  5. Measuring multielectron beam imaging fidelity with a signal-to-noise ratio analysis

    NASA Astrophysics Data System (ADS)

    Mukhtar, Maseeh; Bunday, Benjamin D.; Quoi, Kathy; Malloy, Matt; Thiel, Brad

    2016-07-01

    Java Monte Carlo Simulator for Secondary Electrons (JMONSEL) simulations are used to generate expected imaging responses of chosen test cases of patterns and defects with the ability to vary parameters for beam energy, spot size, pixel size, and/or defect material and form factor. The patterns are representative of the design rules for an aggressively scaled FinFET-type design. With these simulated images and resulting shot noise, a signal-to-noise framework is developed, which relates to defect detection probabilities. Additionally, with this infrastructure, the effect of detection chain noise and frequency-dependent system response can be made, allowing for targeting of best recipe parameters for multielectron beam inspection validation experiments. Ultimately, these results should lead to insights into how such parameters will impact tool design, including necessary doses for defect detection and estimations of scanning speeds for achieving high throughput for high-volume manufacturing.

  6. Catalytic distillation structure

    DOEpatents

    Smith, Jr., Lawrence A.

    1984-01-01

    Catalytic distillation structure for use in reaction distillation columns, a providing reaction sites and distillation structure and consisting of a catalyst component and a resilient component intimately associated therewith. The resilient component has at least about 70 volume % open space and being present with the catalyst component in an amount such that the catalytic distillation structure consist of at least 10 volume % open space.

  7. Small-Diameter Awls Improve Articular Cartilage Repair After Microfracture Treatment in a Translational Animal Model.

    PubMed

    Orth, Patrick; Duffner, Julia; Zurakowski, David; Cucchiarini, Magali; Madry, Henning

    2016-01-01

    Microfracture is the most commonly applied arthroscopic marrow stimulation procedure. Articular cartilage repair is improved when the subchondral bone is perforated by small-diameter microfracture awls compared with larger awls. Controlled laboratory study. Standardized rectangular (4 × 8 mm) full-thickness chondral defects (N = 24) were created in the medial femoral condyle of 16 adult sheep and debrided down to the subchondral bone plate. Three treatment groups (n = 8 defects each) were tested: 6 microfracture perforations using small-diameter awls (1.0 mm; group 1), large-diameter awls (1.2 mm; group 2), or without perforations (debridement control; group 3). Osteochondral repair was assessed at 6 months in vivo using established macroscopic, histological, immunohistochemical, biochemical, and micro-computed tomography analyses. Compared with control defects, histological cartilage repair was always improved after both microfracture techniques (P < .023). Application of 1.0-mm microfracture awls led to a significantly improved histological overall repair tissue quality (7.02 ± 0.70 vs 9.03 ± 0.69; P = .008) and surface grading (1.05 ± 0.28 vs 2.10 ± 0.19; P = .001) compared with larger awls. The small-diameter awl decreased relative bone volume of the subarticular spongiosa (bone volume/tissue volume ratio: 23.81% ± 3.37% vs 30.58% ± 2.46%; P = .011). Subchondral bone cysts and intralesional osteophytes were frequently observed after either microfracture treatment. Macroscopic grading, DNA, proteoglycan, and type I and type II collagen contents as well as degenerative changes within the adjacent cartilage remained unaffected by the awl diameter. Small-diameter microfracture awls improve articular cartilage repair in the translational sheep model more effectively than do larger awls. These data support the use of small microfracture instruments for the surgical treatment of cartilage defects and warrant prolonged clinical investigations. © 2015 The Author(s).

  8. A new proposal to evaluate the healing of open skin wounds: volumetry.

    PubMed

    Paulo, Danilo Nagib Salomão; Fiorot, Antonio Wilson

    2011-12-01

    To present a new proposal to evaluate the healing of an open subcutaneous and skin wound, which we termed "volumetry". A total of 32 circular wounds were performed in the subcutaneous tissues and skin of four feet of pigs (8 each). Each wound had about 1 cm in diameter and was 0.2 cm deep. Volume was calculated from the wound filled with saline and mass Xantopren. With the aid of a magnifying glass and local lighting, the liquid was dripped with a micropipette inside the wound until complete fullness. Volume repletion was calculated in microliters, corresponding to the volume of the wound. The mass of Xantopren was placed inside the wound to obtain a mold of the lesion. Mold volume was calculated using the formula of the volume of a cylinder closest resembling a geometric figure with mold. The calculation of wound volume was possible with both Xantopren and mold techniques. Volume as calculated by micropipette was 119.37 ± 30.87 microliters while the volume calculated by mold was 122.41 ± 33.90 mm3 (p=0.79). Volumetry in pig feet is simple and reproducible. Volumetry perfomed with saline did not differ from the volumetry with mass Xantopren. This method may be a useful tool to help evaluate the healing of open skin wounds in experimental and clinical research.

  9. Selective formation of porous silicon

    NASA Technical Reports Server (NTRS)

    Fathauer, Jones (Inventor)

    1993-01-01

    A pattern of porous silicon is produced in the surface of a silicon substrate by forming a pattern of crystal defects in said surface, preferably by applying an ion milling beam through openings in a photoresist layer to the surface, and then exposing said surface to a stain etchant, such as HF:HNO3:H20. The defected crystal will preferentially etch to form a pattern of porous silicon. When the amorphous content of the porous silicon exceeds 70 percent, the porous silicon pattern emits visible light at room temperature.

  10. Transcatheter closure of Patent Ductus Arteriosus through only venous route.

    PubMed

    Sheikh, Abdul Malik; Duke, Abdul Karim; Sattar, Hina

    2018-03-01

    Patent ductus arteriosus is a common congenital cardiac defect comprising 5-10% of all these defects in term neonates. Although open chest and video-assisted interruption are still in use, transcatheter occlusion has rapidly become the first choice for patent ductus arteriosus closure in the appropriate patient. Percutaneous closure of patent ductus arteriosus is widely done by transvenous approach guided by aortic access. We present the case of a 2 year old girl who underwent patent ductus arteriosus device occlusion with transvenous access only.

  11. Fabrication of custom-shaped grafts for cartilage regeneration.

    PubMed

    Koo, Seungbum; Hargreaves, Brian A; Gold, Garry E; Dragoo, Jason L

    2010-10-01

    to create a custom-shaped graft through 3D tissue shape reconstruction and rapid-prototype molding methods using MRI data, and to test the accuracy of the custom-shaped graft against the original anatomical defect. An iatrogenic defect on the distal femur was identified with a 1.5 Tesla MRI and its shape was reconstructed into a three-dimensional (3D) computer model by processing the 3D MRI data. First, the accuracy of the MRI-derived 3D model was tested against a laser-scan based 3D model of the defect. A custom-shaped polyurethane graft was fabricated from the laser-scan based 3D model by creating custom molds through computer aided design and rapid-prototyping methods. The polyurethane tissue was laser-scanned again to calculate the accuracy of this process compared to the original defect. The volumes of the defect models from MRI and laser-scan were 537 mm3 and 405 mm3, respectively, implying that the MRI model was 33% larger than the laser-scan model. The average (±SD) distance deviation of the exterior surface of the MRI model from the laser-scan model was 0.4 ± 0.4 mm. The custom-shaped tissue created from the molds was qualitatively very similar to the original shape of the defect. The volume of the custom-shaped cartilage tissue was 463 mm3 which was 15% larger than the laser-scan model. The average (±SD) distance deviation between the two models was 0.04 ± 0.19 mm. This investigation proves the concept that custom-shaped engineered grafts can be fabricated from standard sequence 3-D MRI data with the use of CAD and rapid-prototyping technology. The accuracy of this technology may help solve the interfacial problem between native cartilage and graft, if the grafts are custom made for the specific defect. The major source of error in fabricating a 3D custom-shaped cartilage graft appears to be the accuracy of a MRI data itself; however, the precision of the model is expected to increase by the utilization of advanced MR sequences with higher magnet strengths.

  12. Closed-loop mechanical ventilation for lung injury: a novel physiological-feedback mode following the principles of the open lung concept.

    PubMed

    Schwaiberger, David; Pickerodt, Philipp A; Pomprapa, Anake; Tjarks, Onno; Kork, Felix; Boemke, Willehad; Francis, Roland C E; Leonhardt, Steffen; Lachmann, Burkhard

    2018-06-01

    Adherence to low tidal volume (V T ) ventilation and selected positive end-expiratory pressures are low during mechanical ventilation for treatment of the acute respiratory distress syndrome. Using a pig model of severe lung injury, we tested the feasibility and physiological responses to a novel fully closed-loop mechanical ventilation algorithm based on the "open lung" concept. Lung injury was induced by surfactant washout in pigs (n = 8). Animals were ventilated following the principles of the "open lung approach" (OLA) using a fully closed-loop physiological feedback algorithm for mechanical ventilation. Standard gas exchange, respiratory- and hemodynamic parameters were measured. Electrical impedance tomography was used to quantify regional ventilation distribution during mechanical ventilation. Automatized mechanical ventilation provided strict adherence to low V T -ventilation for 6 h in severely lung injured pigs. Using the "open lung" approach, tidal volume delivery required low lung distending pressures, increased recruitment and ventilation of dorsal lung regions and improved arterial blood oxygenation. Physiological feedback closed-loop mechanical ventilation according to the principles of the open lung concept is feasible and provides low tidal volume ventilation without human intervention. Of importance, the "open lung approach"-ventilation improved gas exchange and reduced lung driving pressures by opening atelectasis and shifting of ventilation to dorsal lung regions.

  13. Reliability of steam generator tubing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kadokami, E.

    1997-02-01

    The author presents results on studies made of the reliability of steam generator (SG) tubing. The basis for this work is that in Japan the issue of defects in SG tubing is addressed by the approach that any detected defect should be repaired, either by plugging the tube or sleeving it. However, this leaves open the issue that there is a detection limit in practice, and what is the effect of nondetectable cracks on the performance of tubing. These studies were commissioned to look at the safety issues involved in degraded SG tubing. The program has looked at a numbermore » of different issues. First was an assessment of the penetration and opening behavior of tube flaws due to internal pressure in the tubing. They have studied: penetration behavior of the tube flaws; primary water leakage from through-wall flaws; opening behavior of through-wall flaws. In addition they have looked at the question of the reliability of tubing with flaws during normal plant operation. Also there have been studies done on the consequences of tube rupture accidents on the integrity of neighboring tubes.« less

  14. Cartilage morphology at 2-3 years following anterior cruciate ligament reconstruction with or without concomitant meniscal pathology.

    PubMed

    Wang, Xinyang; Wang, Yuanyuan; Bennell, Kim L; Wrigley, Tim V; Cicuttini, Flavia M; Fortin, Karine; Saxby, David J; Van Ginckel, Ans; Dempsey, Alasdair R; Grigg, Nicole; Vertullo, Christopher; Feller, Julian A; Whitehead, Tim; Lloyd, David G; Bryant, Adam L

    2017-02-01

    To examine differences in cartilage morphology between young adults 2-3 years post-anterior cruciate ligament reconstruction (ACLR), with or without meniscal pathology, and control participants. Knee MRI was performed on 130 participants aged 18-40 years (62 with isolated ACLR, 38 with combined ACLR and meniscal pathology, and 30 healthy controls). Cartilage defects, cartilage volume and bone marrow lesions (BMLs) were assessed from MRI using validated methods. Cartilage defects were more prevalent in the isolated ACLR (69 %) and combined group (84 %) than in controls (10 %, P < 0.001). Furthermore, the combined group showed higher prevalence of cartilage defects on medial femoral condyle (OR 4.7, 95 % CI 1.3-16.6) and patella (OR 7.8, 95 % CI 1.5-40.7) than the isolated ACLR group. Cartilage volume was lower in both ACLR groups compared with controls (medial tibia, lateral tibia and patella, P < 0.05), whilst prevalence of BMLs was higher on lateral tibia (P < 0.001), with no significant differences between the two ACLR groups for either measure. Cartilage morphology was worse in ACLR patients compared with healthy controls. ACLR patients with associated meniscal pathology have a higher prevalence of cartilage defects than ACLR patients without meniscal pathology. The findings suggest that concomitant meniscal pathology may lead to a greater risk of future OA than isolated ACLR. III.

  15. Stress distribution and mechanical properties of free and assembled Ni3Al nanoclusters

    NASA Astrophysics Data System (ADS)

    Zhurkin, E. E.; Hautier, G.; Hou, M.

    2006-03-01

    Classical molecular dynamics with a semiempirical N -body potential is used to study the distribution of local stress in bimetallic Ni3Al nanoparticles and in cluster-assembled materials. The materials considered are synthesized with these particles by low-energy deposition at 0.5eV per atom and by compaction with an external pressure of 2GPa , thus featuring different nanostructures. Both are nanoporous, the lowest density being obtained by deposition. Their mechanical response to a uniaxial external load is then studied and deformation mechanisms are identified and are found to be similar in both nanostructures. In the core of isolated clusters, the partial pressures on the nickel and aluminium subsystems are found to differ by several GPa and, as a balance to surface tension, the hydrostatic core pressure is positive and depends on the cluster size. The surface stress is tensile and, because of structural disorder, the partial pressures distributions on Ni and Al at the surface are scattered. When nanostructured systems are formed, strong and highly inhomogeneous shear stress appears, the cluster cores may become tensile, and the interfacial areas remain mainly tensile as well. The partial pressure difference between Ni and Al is somewhat reduced. It is shown that the effect of temperature is to reduce this difference still further and to homogenize the spatial stress distribution. When subjected to a uniaxial stress, both materials display an elastic and a plastic regime. The elastic limit is the lowest for the most porous material and decreases with increasing temperature. Plastic deformation is dominated by both grain boundary sliding and by the enlargement of the open volumes, without evidence for the nucleation of cracks. These open volumes are found to facilitate dislocation activity which is evidenced in grains with sizes as small as two nanometers. This dislocation activity is found to result in the production of stacking faults as well as to the recovery of defects induced by the deposition or by the compaction.

  16. New Analysis of Solute Drag in AA5754 by Precise Determination of Point Defect Generation and the Orowan Relation

    NASA Astrophysics Data System (ADS)

    Diak, Brad J.; Penlington, Alex; Saimoto, Shig

    Serrated deformation in Al-Mg alloys creates problems that affect consumer product acceptability. This effect is usually attributed to the Portevin-LeChâtelier effect. In this study the inverse PLC effect due to solute drag on moving dislocations is examined in AA5754. The drag mechanism is dependent on the diffusivity of the solute which is in-turn dependent on the point defect evolution during deformation. Experimental determination of the parabolic James-Barnett drag profile by strain rate change experiments indicates the peak stress is centered at 1.5×10-9m/s, which requires a mechanical formation energy for vacancies of 0.4eV/at. A new slip-based constitutive relation was used to determine the evolution of vacancy volume fraction with deformation with strain, which is greater than the volume fraction of vacancies predicted by the solute drag profile.

  17. A Statistics-Based Cracking Criterion of Resin-Bonded Silica Sand for Casting Process Simulation

    NASA Astrophysics Data System (ADS)

    Wang, Huimin; Lu, Yan; Ripplinger, Keith; Detwiler, Duane; Luo, Alan A.

    2017-02-01

    Cracking of sand molds/cores can result in many casting defects such as veining. A robust cracking criterion is needed in casting process simulation for predicting/controlling such defects. A cracking probability map, relating to fracture stress and effective volume, was proposed for resin-bonded silica sand based on Weibull statistics. Three-point bending test results of sand samples were used to generate the cracking map and set up a safety line for cracking criterion. Tensile test results confirmed the accuracy of the safety line for cracking prediction. A laboratory casting experiment was designed and carried out to predict cracking of a cup mold during aluminum casting. The stress-strain behavior and the effective volume of the cup molds were calculated using a finite element analysis code ProCAST®. Furthermore, an energy dispersive spectroscopy fractographic examination of the sand samples confirmed the binder cracking in resin-bonded silica sand.

  18. PAL spectroscopy of rare-earth doped Ga-Ge-Te/Se glasses

    NASA Astrophysics Data System (ADS)

    Shpotyuk, Ya.; Ingram, A.; Shpotyuk, O.

    2016-04-01

    Positron annihilation lifetime (PAL) spectroscopy was applied for the first time to study free-volume void evolution in chalcogenide glasses of Ga-Ge-Te/Se cut-section exemplified by glassy Ga10Ge15Te75 and Ga10Ge15Te72Se3 doped with 500 ppm of Tb3+ or Pr3+. The collected PAL spectra reconstructed within two-state trapping model reveal decaying tendency in positron trapping efficiency in these glasses under rare-earth doping. This effect results in unchanged or slightly increased defect-related lifetimes τ2 at the cost of more strong decrease in I2 intensities, as well as reduced positron trapping rate in defects and fraction of trapped positrons. Observed changes are ascribed to rare-earth activated elimination of intrinsic free volumes associated mainly with negatively-charged states of chalcogen atoms especially those neighboring with Ga-based polyhedrons.

  19. Use of the pericranial flap in medial canthal reconstruction: another application for this versatile flap.

    PubMed

    Leatherbarrow, Brian; Watson, Adam; Wilcsek, Geoffrey

    2006-01-01

    To describe the use and outcomes of a versatile surgical technique in the reconstruction of deep soft tissue and bony defects of the medial canthus. A retrospective review of consecutive cases requiring reconstruction of medial canthal defects involving loss of periosteum or bone by a median forehead pericranial flap and full-thickness skin grafting in a tertiary referral hospital setting. Two techniques were used: an open technique, using a midline forehead incision; and an endoscopic technique, using 2 incisions behind the hairline. Twenty-one cases were identified: 19 open and 2 endoscopic. The average length of follow-up was 13 months (range, 6-50 months). Ten cases required additional oculoplastic procedures including local periosteal flaps and mucous membrane grafts. Two cases (10%) had complete flap failure; one of these was caused by infection. Five (24%) had partial (< 50%) skin graft necrosis. Two cases (10%) have required further surgery. Our experience shows the pericranial flap to be versatile, robust, and easy to manipulate, offering advantages over alternative techniques when used for the repair of deep medial canthal defects. It is a valuable reconstructive technique that can yield good cosmetic and functional results.

  20. Laparoendoscopic Management of Midureteral Strictures

    PubMed Central

    Komninos, Christos; Koo, Kyo Chul

    2014-01-01

    The incidence of ureteral strictures has increased worldwide owing to the widespread use of laparoscopic and endourologic procedures. Midureteral strictures can be managed by either an endoscopic approach or surgical reconstruction, including open or minimally invasive (laparoscopic/robotic) techniques. Minimally invasive surgical ureteral reconstruction is gaining in popularity in the management of midureteral strictures. However, only a few studies have been published so far regarding the safety and efficacy of laparoscopic and robotic ureteral reconstruction procedures. Nevertheless, most of the studies have reported at least equivalent outcomes with the open approach. In general, strictures more than 2 cm, injury strictures, and strictures associated either with radiation or with reduced renal function of less than 25% may be managed more appropriately by minimally invasive surgical reconstruction, although the evidence to establish these recommendations is not yet adequate. Defects of 2 to 3 cm in length may be treated with laparoscopic or robot-assisted uretero-ureterostomy, whereas defects of 12 to 15 cm may be managed either via ureteral reimplantation with a Boari flap or via transuretero-ureterostomy in case of low bladder capacity. Cases with more extended defects can be reconstructed with the incorporation of the ileum in ureteral repair. PMID:24466390

  1. Automated reticle inspection data analysis for wafer fabs

    NASA Astrophysics Data System (ADS)

    Summers, Derek; Chen, Gong; Reese, Bryan; Hutchinson, Trent; Liesching, Marcus; Ying, Hai; Dover, Russell

    2008-10-01

    To minimize potential wafer yield loss due to mask defects, most wafer fabs implement some form of reticle inspection system to monitor photomask quality in high-volume wafer manufacturing environments. Traditionally, experienced operators review reticle defects found by an inspection tool and then manually classify each defect as 'pass, warn, or fail' based on its size and location. However, in the event reticle defects are suspected of causing repeating wafer defects on a completed wafer, potential defects on all associated reticles must be manually searched on a layer-by-layer basis in an effort to identify the reticle responsible for the wafer yield loss. This 'problem reticle' search process is a very tedious and time-consuming task and may cause extended manufacturing line-down situations. Often times, Process Engineers and other team members need to manually investigate several reticle inspection reports to determine if yield loss can be tied to a specific layer. Because of the very nature of this detailed work, calculation errors may occur resulting in an incorrect root cause analysis effort. These delays waste valuable resources that could be spent working on other more productive activities. This paper examines an automated software solution for converting KLA-Tencor reticle inspection defect maps into a format compatible with KLA-Tencor's Klarity DefecTM data analysis database. The objective is to use the graphical charting capabilities of Klarity Defect to reveal a clearer understanding of defect trends for individual reticle layers or entire mask sets. Automated analysis features include reticle defect count trend analysis and potentially stacking reticle defect maps for signature analysis against wafer inspection defect data. Other possible benefits include optimizing reticle inspection sample plans in an effort to support "lean manufacturing" initiatives for wafer fabs.

  2. Finite element analysis on the biomechanical stability of open porous titanium scaffolds for large segmental bone defects under physiological load conditions.

    PubMed

    Wieding, Jan; Souffrant, Robert; Mittelmeier, Wolfram; Bader, Rainer

    2013-04-01

    Repairing large segmental defects in long bones caused by fracture, tumour or infection is still a challenging problem in orthopaedic surgery. Artificial materials, i.e. titanium and its alloys performed well in clinical applications, are plenary available, and can be manufactured in a wide range of scaffold designs. Although the mechanical properties are determined, studies about the biomechanical behaviour under physiological loading conditions are rare. The goal of our numerical study was to determine the suitability of open-porous titanium scaffolds to act as bone scaffolds. Hence, the mechanical stability of fourteen different scaffold designs was characterized under both axial compression and biomechanical loading within a large segmental distal femoral defect of 30mm. This defect was stabilized with an osteosynthesis plate and physiological hip reaction forces as well as additional muscle forces were implemented to the femoral bone. Material properties of titanium scaffolds were evaluated from experimental testing. Scaffold porosity was varied between 64 and 80%. Furthermore, the amount of material was reduced up to 50%. Uniaxial compression testing revealed a structural modulus for the scaffolds between 3.5GPa and 19.1GPa depending on porosity and material consumption. The biomechanical testing showed defect gap alterations between 0.03mm and 0.22mm for the applied scaffolds and 0.09mm for the intact bone. Our results revealed that minimizing the amount of material of the inner core has a smaller influence than increasing the porosity when the scaffolds are loaded under biomechanical loading. Furthermore, an advanced scaffold design was found acting similar as the intact bone. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. [Antegrade extended peroneal artery perforator flap for knee reconstruction].

    PubMed

    Ruan, Hongjiang; Cai, Peihua; Fan, Cunyi; Chai, Yimin; Liu, Shenghe

    2009-03-01

    To investigate the operative technique and clinical results of repairing the soft tissue defects of knee with antegrade extended peroneal artery perforator flap. From October 2007 to January 2008, 3 patients (2 men and 1 woman) with the soft tissue defects of knee were treated, with the ages of 18, 31 and 42 years, respectively. The first case sustained femur and pelvis fractures and soft tissue defect over his right popliteal fossa, which were treated with open reduction and internal fixation (ORIF) and debridement of knee joint 2 weeks ago. The second case was necrosis of skin 3 weeks after ORIF for fracture of tibial plateau. The third case suffered from open fracture of tibial plateau and soft tissue defect, which were treated with external fixation and debridement 3 weeks ago. The defect sizes were 16 cm x 9 cm, 11 cm x 6 cm and 14 cm x 7 cm. The flap was raised by dividing the peroneal artery and veins distally and elevating them proximally, which covered for the defects of knee. The flaps were designed with the size of 18 cm x 10 cm, 12 cm 7 cm and 15 cm x 8 cm. The pure vascular pedicle of the flap was 10 cm to 17 cm in length, including the peroneal vessels and one or two perforator branches. The donor site is covered by a split thickness skin graft. All flaps survived after surgery. The donor sites healed by first intention and the skin grafts survived. After following up for 6, 8 and 11 months, the appearance and function of the flaps were all satisfactory. Based on the modified HSS knee performance system, post-operative knee functional outcomes of three patients were excellent. The antegrade extended peroneal artery perforator flap supplied by a pure vascular pedicle can be a good alternative for reconstruction of knee. The flap, with a long and thin pure vascular pedicle, could provide good texture and contour matching the recipient area.

  4. ECM Inspired Coating of Embroidered 3D Scaffolds Enhances Calvaria Bone Regeneration

    PubMed Central

    Rentsch, C.; Rentsch, B.; Heinemann, S.; Bernhardt, R.; Bischoff, B.; Förster, Y.; Scharnweber, D.; Rammelt, S.

    2014-01-01

    Resorbable polymeric implants and surface coatings are an emerging technology to treat bone defects and increase bone formation. This approach is of special interest in anatomical regions like the calvaria since adults lose the capacity to heal large calvarial defects. The present study assesses the potential of extracellular matrix inspired, embroidered polycaprolactone-co-lactide (PCL) scaffolds for the treatment of 13 mm full thickness calvarial bone defects in rabbits. Moreover the influence of a collagen/chondroitin sulfate (coll I/cs) coating of PCL scaffolds was evaluated. Defect areas filled with autologous bone and empty defects served as reference. The healing process was monitored over 6 months by combining a novel ultrasonographic method, radiographic imaging, biomechanical testing, and histology. The PCL coll I/cs treated group reached 68% new bone volume compared to the autologous group (100%) and the biomechanical stability of the defect area was similar to that of the gold standard. Histological investigations revealed a significantly more homogenous bone distribution over the whole defect area in the PCL coll I/cs group compared to the noncoated group. The bioactive, coll I/cs coated, highly porous, 3-dimensional PCL scaffold acted as a guide rail for new skull bone formation along and into the implant. PMID:25013767

  5. The Detection of Burn-Through Weld Defects Using Noncontact Ultrasonics

    PubMed Central

    Abbasi, Zeynab; Yuhas, Donald; Zhang, Lu; Basantes, Alexandra-Del-Carmen; Tehrani, Niloofar Nabili; Ozevin, Didem; Indacochea, Ernesto

    2018-01-01

    Nearly all manufactured products in the metal industry involve welding. The detection and correction of defects during welding improve the product reliability and quality, and prevent unexpected failures. Nonintrusive process control is critical for avoiding these defects. This paper investigates the detection of burn-through damage using noncontact, air-coupled ultrasonics, which can be adapted to the immediate and in-situ inspection of welded samples. The burn-through leads to a larger volume of degraded weld zone, providing a resistance path for the wave to travel which results in lower velocity, energy ratio, and amplitude. Wave energy dispersion occurs due to the increase of weld burn-through resulting in higher wave attenuation. Weld sample micrographs are used to validate the ultrasonic results. PMID:29342875

  6. Nondestructive testing of moisture separator reheater tubing system using Hall sensor array

    NASA Astrophysics Data System (ADS)

    Le, Minhhuy; Kim, Jungmin; Kim, Jisoo; Do, Hwa Sik; Lee, Jinyi

    2018-01-01

    This paper presents a nondestructive testing system for inspecting the moisture separator reheater (MSR) tubing system in a nuclear power plant. The technique is based on partial saturation eddy current testing in which a Hall sensor array is used to measure the radial component of the electromagnetic field distributed in the tubes. A finned MRS tube of ferritic stainless steel (SS439) with artificial, flat-bottom hole-type defects was used in the experiments. The results show that the proposed system has potential applications in the MSR system or ferromagnetic material tubes in general, which could detect the artificial defects of about 20% of the wall thickness (0.24 mm). Furthermore, the defect volume could be quantitatively evaluated.

  7. Genetics Home Reference: supravalvular aortic stenosis

    MedlinePlus

    ... Twitter Home Health Conditions Supravalvular aortic stenosis Supravalvular aortic stenosis Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Supravalvular aortic stenosis (SVAS) is a heart defect that develops before ...

  8. Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect

    PubMed Central

    Mahdavi, Hoda; Jabbari, Keyvan; Roayaei, Mahnaz

    2016-01-01

    Delivering radiotherapy to the postmastectomy chest wall can be achieved using matched electron fields. Surgical defects of the chest wall change the dose distribution of electrons. In this study, the improvement of dose homogeneity using simple, nonconformal techniques of thermoplastic bolus application on a defect is evaluated. The proposed phantom design improves the capability of film dosimetry for obtaining dose profiles of a patient's anatomical condition. A modeled electron field of a patient with a postmastectomy inward surgical defect was planned. High energy electrons were delivered to the phantom in various settings, including no bolus, a bolus that filled the inward defect (PB0), a uniform thickness bolus of 5 mm (PB1), and two 5 mm boluses (PB2). A reduction of mean doses at the base of the defect was observed by any bolus application. PB0 increased the dose at central parts of the defect, reduced hot areas at the base of steep edges, and reduced dose to the lung and heart. Thermoplastic boluses that compensate a defect (PB0) increased the homogeneity of dose in a fixed depth from the surface; adversely, PB2 increased the dose heterogeneity. This study shows that it is practical to investigate dose homogeneity profiles inside a target volume for various techniques of electron therapy. PMID:27051169

  9. Osteogenic capacity of nanocrystalline bone cement in a weight-bearing defect at the ovine tibial metaphysis.

    PubMed

    Harms, Christoph; Helms, Kai; Taschner, Tibor; Stratos, Ioannis; Ignatius, Anita; Gerber, Thomas; Lenz, Solvig; Rammelt, Stefan; Vollmar, Brigitte; Mittlmeier, Thomas

    2012-01-01

    The synthetic material Nanobone(®) (hydroxyapatite nanocrystallines embedded in a porous silica gel matrix) was examined in vivo using a standardized bone defect model in the ovine tibial metaphysis. A standardized 6 × 12 × 24-mm bone defect was created below the articular surface of the medial tibia condyles on both hind legs of 18 adult sheep. The defect on the right side was filled with Nanobone(®), while the defect on the contralateral side was left empty. The tibial heads of six sheep were analyzed after 6, 12, and 26 weeks each. The histological and radiological analysis of the defect on the control side did not reveal any bone formation after the total of 26 weeks. In contrast, the microcomputed tomography analysis of the defect filled with Nanobone(®) showed a 55%, 72%, and 74% volume fraction of structures with bone density after 6, 12, and 26 weeks, respectively. Quantitative histomorphological analysis after 6, and 12 weeks revealed an osteoneogenesis of 22%, and 36%, respectively. Hematoxylin and eosin sections demonstrated multinucleated giant cells on the surface of the biomaterial and resorption lacunae, indicating osteoclastic resorptive activity. Nanobone(®) appears to be a highly potent bone substitute material with osteoconductive properties in a loaded large animal defect model, supporting the potential use of Nanobone(®) also in humans.

  10. Osteogenic capacity of nanocrystalline bone cement in a weight-bearing defect at the ovine tibial metaphysis

    PubMed Central

    Harms, Christoph; Helms, Kai; Taschner, Tibor; Stratos, Ioannis; Ignatius, Anita; Gerber, Thomas; Lenz, Solvig; Rammelt, Stefan; Vollmar, Brigitte; Mittlmeier, Thomas

    2012-01-01

    The synthetic material Nanobone® (hydroxyapatite nanocrystallines embedded in a porous silica gel matrix) was examined in vivo using a standardized bone defect model in the ovine tibial metaphysis. A standardized 6 × 12 × 24-mm bone defect was created below the articular surface of the medial tibia condyles on both hind legs of 18 adult sheep. The defect on the right side was filled with Nanobone®, while the defect on the contralateral side was left empty. The tibial heads of six sheep were analyzed after 6, 12, and 26 weeks each. The histological and radiological analysis of the defect on the control side did not reveal any bone formation after the total of 26 weeks. In contrast, the microcomputed tomography analysis of the defect filled with Nanobone® showed a 55%, 72%, and 74% volume fraction of structures with bone density after 6, 12, and 26 weeks, respectively. Quantitative histomorphological analysis after 6, and 12 weeks revealed an osteoneogenesis of 22%, and 36%, respectively. Hematoxylin and eosin sections demonstrated multinucleated giant cells on the surface of the biomaterial and resorption lacunae, indicating osteoclastic resorptive activity. Nanobone® appears to be a highly potent bone substitute material with osteoconductive properties in a loaded large animal defect model, supporting the potential use of Nanobone® also in humans. PMID:22745551

  11. Implantation of Autologous Cartilage Chips Improves Cartilage Repair Tissue Quality in Osteochondral Defects: A Study in Göttingen Minipigs.

    PubMed

    Christensen, Bjørn Borsøe; Foldager, Casper Bindzus; Olesen, Morten Lykke; Hede, Kris Chadwick; Lind, Martin

    2016-06-01

    Osteochondral injuries have poor endogenous healing potential, and no standard treatment has been established. The use of combined layered autologous bone and cartilage chips for treatment of osteochondral defects has shown promising short-term clinical results. This study aimed to investigate the role of cartilage chips by comparing combined layered autologous bone and cartilage chips with autologous bone implantation alone in a Göttingen minipig model. The hypothesis was that the presence of cartilage chips would improve the quality of the repair tissue. Controlled laboratory study. Twelve Göttingen minipigs received 2 osteochondral defects in each knee. The defects were randomized to autologous bone graft (ABG) combined with autologous cartilage chips (autologous dual-tissue transplantation [ADTT]) or ABG alone. Six animals were euthanized at 6 months and 6 animals were euthanized at 12 months. Follow-up evaluation consisted of histomorphometry, immunohistochemistry, semiquantitative scoring (International Cartilage Repair Society II), and computed tomography. There was significantly more hyaline cartilage in the ADTT group (25.8%) compared with the ABG group (12.8%) at 6 months after treatment. At 12 months, the fraction of hyaline cartilage in the ABG group had significantly decreased to 4.8%, whereas the fraction of hyaline cartilage in the ADTT group was unchanged (20.1%). At 6 and 12 months, there was significantly more fibrocartilage in the ADTT group (44% and 60.8%) compared with the ABG group (24.5% and 41%). The fraction of fibrous tissue was significantly lower in the ADTT group compared with the ABG group at both 6 and 12 months. The implanted cartilage chips stained >75% positive for collagen type 4 and laminin at both 6 and 12 months. Significant differences were found in a number of International Cartilage Repair Society II subcategories. The volume of the remaining bone defect significantly decreased from 6 to 12 months in both treatment groups; however, no difference in volume was found between the groups at either 6 or 12 months. The presence of cartilage chips in an osteochondral defect facilitated the formation of fibrocartilage as opposed to fibrous tissue at both 6 and 12 months posttreatment. The implanted chips were present in the defect and viable after 12 months. This study substantiates the chondrogenic role of cartilage chips in osteochondral defects. © 2016 The Author(s).

  12. Site Redistribution, Partial Frozen-in Defect Chemistry, and Electrical Properties of Ba1-x(Zr,Pr)O3-δ.

    PubMed

    Antunes, Isabel; Mikhalev, Sergey; Mather, Glenn Christopher; Kharton, Vladislav Vadimovich; Figueiras, Fábio Gabriel; Alves, Adriana; Rodrigues, Joana; Correia, Maria Rosário; Frade, Jorge Ribeiro; Fagg, Duncan Paul

    2016-09-06

    Changes in nominal composition of the perovskite (ABO3) solid solution Ba1-x(Zr,Pr)O3-δ and adjusted firing conditions at very high temperatures were used to induce structural changes involving site redistribution and frozen-in point defects, as revealed by Raman and photoluminescence spectroscopies. Complementary magnetic measurements allowed quantification of the reduced content of Pr. Weak dependence of oxygen stoichiometry with temperature was obtained by coulometric titration at temperatures below 1000 °C, consistent with a somewhat complex partial frozen-in defect chemistry. Electrical conductivity measurements combined with transport number and Seebeck coefficient measurements showed prevailing electronic transport and also indicated trends expected for partial frozen-in conditions. Nominal Ba deficiency and controlled firing at very high temperatures allows adjustment of structure and partial frozen-in defect chemistry, opening the way to engineer relevant properties for high-temperature electrochemical applications.

  13. Topological defect formation and spontaneous symmetry breaking in ion Coulomb crystals.

    PubMed

    Pyka, K; Keller, J; Partner, H L; Nigmatullin, R; Burgermeister, T; Meier, D M; Kuhlmann, K; Retzker, A; Plenio, M B; Zurek, W H; del Campo, A; Mehlstäubler, T E

    2013-01-01

    Symmetry breaking phase transitions play an important role in nature. When a system traverses such a transition at a finite rate, its causally disconnected regions choose the new broken symmetry state independently. Where such local choices are incompatible, topological defects can form. The Kibble-Zurek mechanism predicts the defect densities to follow a power law that scales with the rate of the transition. Owing to its ubiquitous nature, this theory finds application in a wide field of systems ranging from cosmology to condensed matter. Here we present the successful creation of defects in ion Coulomb crystals by a controlled quench of the confining potential, and observe an enhanced power law scaling in accordance with numerical simulations and recent predictions. This simple system with well-defined critical exponents opens up ways to investigate the physics of non-equilibrium dynamics from the classical to the quantum regime.

  14. Effect of Buckling Modes on the Fatigue Life and Damage Tolerance of Stiffened Structures

    NASA Technical Reports Server (NTRS)

    Davila, Carlos G.; Bisagni, Chiara; Rose, Cheryl A.

    2015-01-01

    The postbuckling response and the collapse of composite specimens with a co-cured hat stringer are investigated experimentally and numerically. These specimens are designed to evaluate the postbuckling response and the effect of an embedded defect on the collapse load and the mode of failure. Tests performed using controlled conditions and detailed instrumentation demonstrate that the damage tolerance, fatigue life, and collapse loads are closely tied with the mode of the postbuckling deformation, which can be different between two nominally identical specimens. Modes that tend to open skin/stringer defects are the most damaging to the structure. However, skin/stringer bond defects can also propagate under shearing modes. In the proposed paper, the effects of initial shape imperfections on the postbuckling modes and the interaction between different postbuckling deformations and the propagation of skin/stringer bond defects under quasi-static or fatigue loads will be examined.

  15. Guiding electrical current in nanotube circuits using structural defects: a step forward in nanoelectronics.

    PubMed

    Romo-Herrera, Jose M; Terrones, Mauricio; Terrones, Humberto; Meunier, Vincent

    2008-12-23

    Electrical current could be efficiently guided in 2D nanotube networks by introducing specific topological defects within the periodic framework. Using semiempirical transport calculations coupled with Landauer-Buttiker formalism of quantum transport in multiterminal nanoscale systems, we provide a detailed analysis of the processes governing the atomic-scale design of nanotube circuits. We found that when defects are introduced as patches in specific sites, they act as bouncing centers that reinject electrons along specific paths, via a wave reflection process. This type of defects can be incorporated while preserving the 3-fold connectivity of each carbon atom embedded within the graphitic lattice. Our findings open up a new way to explore bottom-up design, at the nanometer scale, of complex nanotube circuits which could be extended to 3D nanosystems and applied in the fabrication of nanoelectronic devices.

  16. The Electrophysiologic Effects of Acute Mitral Regurgitation in a Canine Model.

    PubMed

    Lawrance, Christopher P; Henn, Matthew C; Miller, Jacob R; Kopek, Michael A; Zhang, Andrew J; Schuessler, Richard B; Damiano, Ralph J

    2017-04-01

    Atrial fibrillation (AF) occurs in 30% of patients with mitral regurgitation referred for surgical intervention. However, the underlying mechanisms in this population are poorly understood. This study examined the effects of acute left atrial volume overload on atrial electrophysiology and the inducibility of AF. Ten canines underwent insertion of an atrioventricular shunt between the left ventricle and left atrium. Shunt and aortic flows were calculated, and the shunt was titrated to a shunt fraction to 40% to 50% of cardiac output. An epicardial plaque with 250 bipolar electrodes was used to determine activation and refractory periods. Biatrial pressures and volumes, conduction times, and atrial fibrillation inducibility were recorded. Data were collected at baseline and 20 minutes after shunt opening and closure. Mean shunt flow was 1.3 ± 0.5 L/min with a shunt fraction of 43% ± 6% simulating moderate to severe mitral regurgitation. Compared with baseline, left atrial volumes and maximum pressures increased by 27% and 29%, respectively, after shunt opening. Biatrial effective refractory periods did not change significantly after shunt opening or closure. Conduction times increased by 9% with shunt opening and returned to baseline after closure. AF duration or inducibility did not change with shunt opening. This canine model of mitral regurgitation demonstrated that acute left atrial volume overload did not increase the inducibility of atrial arrhythmias in contrast with experimental and clinical findings of chronic left atrial volume overload. This suggests that the substrates for AF in patients with mitral regurgitation are a result of chronic remodeling. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  17. High purith low defect FZ silicon

    NASA Technical Reports Server (NTRS)

    Kimura, H.; Robertson, G.

    1985-01-01

    The most common intrinsic defects in dislocation-free float zone (FZ) silicon crystals are the A- and B-type swirl defects. The mechanisms of their formation and annihilation have been extensively studied. Another type of defect in dislocation-free FZ crystals is referred to as a D-type defect. Concentrations of these defects can be minimized by optimizing the growth conditions, and the residual swirls can be reduced by the post-growth extrinsic gettering process. Czochralski (Cz) silicon wafers are known to exhibit higher resistance to slip and warpage due to thermal stress than do FZ wafers. The Cz crystals containing dislocations are more resistant to dislocation movement than dislocated FZ crystals because of the locking of dislocations by oxygen atoms present in the Cz crystals. Recently a transverse magnetic field was applied during the FZ growth of extrinsic silicon. Resultant flow patterns, as revealed by striation etching and spreading resistance in Ga-doped silicon crystals, indicate strong effects of the transverse magnetic field on the circulation within the melt. At fields of 5500 gauss, the fluid flow in the melt volume is so altered as to affect the morphology of the growing crystal.

  18. Prevention of congenital defects induced by prenatal alcohol exposure (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Sheehan, Megan M.; Karunamuni, Ganga; Pedersen, Cameron J.; Gu, Shi; Doughman, Yong Qiu; Jenkins, Michael W.; Watanabe, Michiko; Rollins, Andrew M.

    2017-02-01

    Nearly 2 million women in the United States alone are at risk for an alcohol-exposed pregnancy, including more than 600,000 who binge drink. Even low levels of prenatal alcohol exposure (PAE) can lead to a variety of birth defects, including craniofacial and neurodevelopmental defects, as well as increased risk of miscarriages and stillbirths. Studies have also shown an interaction between drinking while pregnant and an increase in congenital heart defects (CHD), including atrioventricular septal defects and other malformations. We have previously established a quail model of PAE, modeling a single binge drinking episode in the third week of a woman's pregnancy. Using optical coherence tomography (OCT), we quantified intraventricular septum thickness, great vessel diameters, and atrioventricular valve volumes. Early-stage ethanol-exposed embryos had smaller cardiac cushions (valve precursors) and increased retrograde flow, while late-stage embryos presented with gross head/body defects, and exhibited smaller atrio-ventricular (AV) valves, interventricular septum, and aortic vessels. We previously showed that supplementation with the methyl donor betaine reduced gross defects, improved survival rates, and prevented cardiac defects. Here we show that these preventative effects are also observed with folate (another methyl donor) supplementation. Folate also appears to normalize retrograde flow levels which are elevated by ethanol exposure. Finally, preliminary findings have shown that glutathione, a crucial antioxidant, is noticeably effective at improving survival rates and minimizing gross defects in ethanol-exposed embryos. Current investigations will examine the impact of glutathione supplementation on PAE-related CHDs.

  19. Stomatal action directly feeds back on leaf turgor: new insights into the regulation of the plant water status from non-invasive pressure probe measurements.

    PubMed

    Ache, Peter; Bauer, Hubert; Kollist, Hannes; Al-Rasheid, Khaled A S; Lautner, Silke; Hartung, Wolfram; Hedrich, Rainer

    2010-06-01

    Uptake of CO(2) by the leaf is associated with loss of water. Control of stomatal aperture by volume changes of guard cell pairs optimizes the efficiency of water use. Under water stress, the protein kinase OPEN STOMATA 1 (OST1) activates the guard-cell anion release channel SLOW ANION CHANNEL-ASSOCIATED 1 (SLAC1), and thereby triggers stomatal closure. Plants with mutated OST1 and SLAC1 are defective in guard-cell turgor regulation. To study the effect of stomatal movement on leaf turgor using intact leaves of Arabidopsis, we used a new pressure probe to monitor transpiration and turgor pressure simultaneously and non-invasively. This probe permits routine easy access to parameters related to water status and stomatal conductance under physiological conditions using the model plant Arabidopsis thaliana. Long-term leaf turgor pressure recordings over several weeks showed a drop in turgor during the day and recovery at night. Thus pressure changes directly correlated with the degree of plant transpiration. Leaf turgor of wild-type plants responded to CO(2), light, humidity, ozone and abscisic acid (ABA) in a guard cell-specific manner. Pressure probe measurements of mutants lacking OST1 and SLAC1 function indicated impairment in stomatal responses to light and humidity. In contrast to wild-type plants, leaves from well-watered ost1 plants exposed to a dry atmosphere wilted after light-induced stomatal opening. Experiments with open stomata mutants indicated that the hydraulic conductance of leaf stomata is higher than that of the root-shoot continuum. Thus leaf turgor appears to rely to a large extent on the anion channel activity of autonomously regulated stomatal guard cells.

  20. Catalytic distillation structure

    DOEpatents

    Smith, L.A. Jr.

    1984-04-17

    Catalytic distillation structure is described for use in reaction distillation columns, and provides reaction sites and distillation structure consisting of a catalyst component and a resilient component intimately associated therewith. The resilient component has at least about 70 volume % open space and is present with the catalyst component in an amount such that the catalytic distillation structure consists of at least 10 volume % open space. 10 figs.

  1. Coarse woody debris in managed central hardwood forests of Indiana, USA

    Treesearch

    Michael A. Jenkins; Christopher R. Webster; George R. Parker; Martin A. Spetich

    2004-01-01

    We evaluated the volume of down deadwood (DDW) and the basal area of standing deadwood (SDW) from a chronosequence of 110 silvicultural openings and 34 mature stands (72-105 years old) across three Ecological Landtype Phases (ELTP; wet-mesic bottomlands, mesic slopes, and dry-mesic slopes) in southern Indiana, USA. The volume of DDW decreased with increasing opening...

  2. Magnetic resonance imaging can accurately assess the long-term progression of knee structural changes in experimental dog osteoarthritis.

    PubMed

    Boileau, C; Martel-Pelletier, J; Abram, F; Raynauld, J-P; Troncy, E; D'Anjou, M-A; Moreau, M; Pelletier, J-P

    2008-07-01

    Osteoarthritis (OA) structural changes take place over decades in humans. MRI can provide precise and reliable information on the joint structure and changes over time. In this study, we investigated the reliability of quantitative MRI in assessing knee OA structural changes in the experimental anterior cruciate ligament (ACL) dog model of OA. OA was surgically induced by transection of the ACL of the right knee in five dogs. High resolution three dimensional MRI using a 1.5 T magnet was performed at baseline, 4, 8 and 26 weeks post surgery. Cartilage volume/thickness, cartilage defects, trochlear osteophyte formation and subchondral bone lesion (hypersignal) were assessed on MRI images. Animals were killed 26 weeks post surgery and macroscopic evaluation was performed. There was a progressive and significant increase over time in the loss of knee cartilage volume, the cartilage defect and subchondral bone hypersignal. The trochlear osteophyte size also progressed over time. The greatest cartilage loss at 26 weeks was found on the tibial plateaus and in the medial compartment. There was a highly significant correlation between total knee cartilage volume loss or defect and subchondral bone hypersignal, and also a good correlation between the macroscopic and the MRI findings. This study demonstrated that MRI is a useful technology to provide a non-invasive and reliable assessment of the joint structural changes during the development of OA in the ACL dog model. The combination of this OA model with MRI evaluation provides a promising tool for the evaluation of new disease-modifying osteoarthritis drugs (DMOADs).

  3. Isolated Mesoporous Microstructures Prepared by Stress Localization-Induced Crack Manipulation.

    PubMed

    Wooh, Sanghyuk; Lee, Soojin; Lee, Yunchan; Ryu, Ji Ho; Lee, Won Bo; Yoon, Hyunsik; Char, Kookheon

    2016-09-22

    Cracks observed in brittle materials are mostly regarded as defects or failures. However, they can be a valuable tool when implemented in a controlled way. Here, we introduce a strategy to control the crack propagation of mesoporous micropatterns (prisms and pyramids), which leads to the isolation of well-defined microstructures. Mesoporous micropatterns were fabricated by the soft imprinting technique with wet TiO 2 nanoparticle (NP) pastes, followed by sintering to remove organic components. Since the volume of the paste significantly shrinks during the sintering step, stress is localized at the edge of micropatterns, in good agreement with finite element method simulations, creating well-defined cracks and their propagation. It was demonstrated that the degree of stress localization is determined by the thickness of residual layers, NP size, and heating rate. After controlled crack propagation and delamination of microparticles from the substrates, mesoporous microwires and microparticles were successfully produced and functionalized from the isolated mesoporous prisms and pyramids. The method proposed in this study for controlled crack manipulation and delamination opens a door for straightforward and economical fabrication of well-defined mesoporous microparticles.

  4. Development of visual field defect after first-detected optic disc hemorrhage in preperimetric open-angle glaucoma.

    PubMed

    Kim, Hae Jin; Song, Yong Ju; Kim, Young Kook; Jeoung, Jin Wook; Park, Ki Ho

    2017-07-01

    To evaluate functional progression in preperimetric glaucoma (PPG) with disc hemorrhage (DH) and to determine the time interval between the first-detected DH and development of glaucomatous visual field (VF) defect. A total of 87 patients who had been first diagnosed with PPG were enrolled. The medical records of PPG patients without DH (Group 1) and with DH (Group 2) were reviewed. When glaucomatous VF defect appeared, the time interval from the diagnosis of PPG to the development of VF defect was calculated and compared between the two groups. In group 2, the time intervals from the first-detected DH to VF defect of the single- and recurrent-DH were compared. Of the enrolled patients, 45 had DH in the preperimetric stage. The median time interval from the diagnosis of PPG to the development of VF defect was 73.3 months in Group 1, versus 45.4 months in Group 2 (P = 0.042). The cumulative probability of development of VF defect after diagnosis of PPG was significantly greater in Group 2 than in Group 1. The median time interval from first-detected DH to the development of VF defect was 37.8 months. The median time interval from DH to VF defect and cumulative probability of VF defect after DH did not show a statistical difference between single and recurrent-DH patients. The median time interval between the diagnosis of PPG and the development of VF defect was significantly shorter in PPG with DH. The VF defect appeared 37.8 months after the first-detected DH in PPG.

  5. Immersion lithography defectivity analysis at DUV inspection wavelength

    NASA Astrophysics Data System (ADS)

    Golan, E.; Meshulach, D.; Raccah, N.; Yeo, J. Ho.; Dassa, O.; Brandl, S.; Schwarz, C.; Pierson, B.; Montgomery, W.

    2007-03-01

    Significant effort has been directed in recent years towards the realization of immersion lithography at 193nm wavelength. Immersion lithography is likely a key enabling technology for the production of critical layers for 45nm and 32nm design rule (DR) devices. In spite of the significant progress in immersion lithography technology, there remain several key technology issues, with a critical issue of immersion lithography process induced defects. The benefits of the optical resolution and depth of focus, made possible by immersion lithography, are well understood. Yet, these benefits cannot come at the expense of increased defect counts and decreased production yield. Understanding the impact of the immersion lithography process parameters on wafer defects formation and defect counts, together with the ability to monitor, control and minimize the defect counts down to acceptable levels is imperative for successful introduction of immersion lithography for production of advanced DR's. In this report, we present experimental results of immersion lithography defectivity analysis focused on topcoat layer thickness parameters and resist bake temperatures. Wafers were exposed on the 1150i-α-immersion scanner and 1200B Scanner (ASML), defect inspection was performed using a DUV inspection tool (UVision TM, Applied Materials). Higher sensitivity was demonstrated at DUV through detection of small defects not detected at the visible wavelength, indicating on the potential high sensitivity benefits of DUV inspection for this layer. The analysis indicates that certain types of defects are associated with different immersion process parameters. This type of analysis at DUV wavelengths would enable the optimization of immersion lithography processes, thus enabling the qualification of immersion processes for volume production.

  6. Prevention of internal hernias and pelvic adhesions following laparoscopic left-sided colorectal resection: the role of fibrin sealant.

    PubMed

    Angelini, Pierluigi; Sciuto, Antonio; Cuccurullo, Diego; Pirozzi, Felice; Reggio, Stefano; Corcione, Francesco

    2017-07-01

    Laparoscopy has increasingly become the standard of care for patients who undergo colorectal surgery for both benign and malignant diseases. This growing experience has also resulted in more reports of postoperative complications from the minimally invasive approach to primary colorectal resection. Small bowel obstruction from internal hernias and pre-sacral adhesions is an uncommon but not negligible complication. However, there is little literature specific to this topic with recommendations for different methods to prevent it. We report our original technique of closing the mesenteric defect and covering the pre-sacral fascia by using fibrin sealant to prevent this complication. From January 2005 to December 2014, a total of 1079 patients underwent elective laparoscopic left colorectal resection (left hemicolectomy or anterior rectal resection) in our department. In the first 298 procedures, the mesenteric defect was left open, while in the following 781 procedures, it was closed using fibrin sealant with the aim of preventing postoperative small bowel obstruction. Among the first 298 patients, three (1%) required reoperation for small bowel obstruction due to internal hernia (0.33%) or critical pre-sacral adhesions (0.66%). These complications did not occur in the subsequent series in which all 781 patients were treated with fibrin sealant prophylactic closure of the mesenteric defect. In our experience, fibrin sealant closure of the mesenteric defect has demonstrated to be safe and effective in preventing postoperative small bowel obstruction that remains a complication both in open and in laparoscopic colorectal surgeries.

  7. IR-LTS a powerful non-invasive tool to observe crystal defects in as-grown silicon, after device processing, and in heteroepitaxial layers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kissinger, G.; Richter, H.; Vanhellemont, J.

    1996-12-01

    One of the main advantages of infrared light scattering tomography (IR-LST) is the wide range of defect densities that can be studied using this technique. As-grown defects of low density and very small size as well as oxygen precipitation related defects that appear in densities up to some 1010 cm{sup -3} can be observed. As-grown wafers with a {open_quotes}stacking fault ring{close_quotes} were investigated in order to correlate the defects observed by IR-LST with the results of Secco etching and alcaline cleaning solution (SC1) treatment revealing flow pattern defects (FPDs) and crystal originated particles (COPs), respectively. These wafers were studied aftermore » a wet oxidation at 1100{degrees}C for 100 min. In processed CZ silicon wafers it was possible to identify stacking faults and prismatic punching systems directly from the IR-LST image. Brewster angle illumination is a special mode to reveal defects in epitaxial layers in a non-destructive way. Misfit dislocations in the interface between a Ge{sub 0.92}Si{sub 0.08} layer and a silicon substrate were studied using this mode that allows to observe very low dislocation densities.« less

  8. Electron-pinned defect-dipoles for high-performance colossal permittivity materials

    NASA Astrophysics Data System (ADS)

    Hu, Wanbiao; Liu, Yun; Withers, Ray L.; Frankcombe, Terry J.; Norén, Lasse; Snashall, Amanda; Kitchin, Melanie; Smith, Paul; Gong, Bill; Chen, Hua; Schiemer, Jason; Brink, Frank; Wong-Leung, Jennifer

    2013-09-01

    The immense potential of colossal permittivity (CP) materials for use in modern microelectronics as well as for high-energy-density storage applications has propelled much recent research and development. Despite the discovery of several new classes of CP materials, the development of such materials with the required high performance is still a highly challenging task. Here, we propose a new electron-pinned, defect-dipole route to ideal CP behaviour, where hopping electrons are localized by designated lattice defect states to generate giant defect-dipoles and result in high-performance CP materials. We present a concrete example, (Nb+In) co-doped TiO2 rutile, that exhibits a largely temperature- and frequency-independent colossal permittivity (> 104) as well as a low dielectric loss (mostly < 0.05) over a very broad temperature range from 80 to 450 K. A systematic defect analysis coupled with density functional theory modelling suggests that ‘triangular’ In23+VO••Ti3+ and ‘diamond’ shaped Nb25+Ti3+ATi (A  =  Ti3+/In3+/Ti4+) defect complexes are strongly correlated, giving rise to large defect-dipole clusters containing highly localized electrons that are together responsible for the excellent CP properties observed in co-doped TiO2. This combined experimental and theoretical work opens up a promising feasible route to the systematic development of new high-performance CP materials via defect engineering.

  9. Electron-pinned defect-dipoles for high-performance colossal permittivity materials.

    PubMed

    Hu, Wanbiao; Liu, Yun; Withers, Ray L; Frankcombe, Terry J; Norén, Lasse; Snashall, Amanda; Kitchin, Melanie; Smith, Paul; Gong, Bill; Chen, Hua; Schiemer, Jason; Brink, Frank; Wong-Leung, Jennifer

    2013-09-01

    The immense potential of colossal permittivity (CP) materials for use in modern microelectronics as well as for high-energy-density storage applications has propelled much recent research and development. Despite the discovery of several new classes of CP materials, the development of such materials with the required high performance is still a highly challenging task. Here, we propose a new electron-pinned, defect-dipole route to ideal CP behaviour, where hopping electrons are localized by designated lattice defect states to generate giant defect-dipoles and result in high-performance CP materials. We present a concrete example, (Nb+In) co-doped TiO₂ rutile, that exhibits a largely temperature- and frequency-independent colossal permittivity (> 10(4)) as well as a low dielectric loss (mostly < 0.05) over a very broad temperature range from 80 to 450 K. A systematic defect analysis coupled with density functional theory modelling suggests that 'triangular' In₂(3+)Vo(••)Ti(3+) and 'diamond' shaped Nb₂(5+)Ti(3+)A(Ti) (A = Ti(3+)/In(3+)/Ti(4+)) defect complexes are strongly correlated, giving rise to large defect-dipole clusters containing highly localized electrons that are together responsible for the excellent CP properties observed in co-doped TiO₂. This combined experimental and theoretical work opens up a promising feasible route to the systematic development of new high-performance CP materials via defect engineering.

  10. Single-Crystalline Ultrathin Co 3O 4 Nanosheets with Massive Vacancy Defects for Enhanced Electrocatalysis

    DOE PAGES

    Cai, Zhao; Bi, Yongmin; Hu, Enyuan; ...

    2017-09-18

    The role of vacancy defects is demonstrated to be positive in various energy-related processes. However, introducing vacancy defects into single-crystalline nanostructures with given facets and studying their defect effect on electrocatalytic properties remains a great challenge. Here this paper deliberately introduces oxygen defects into single-crystalline ultrathin Co 3O 4 nanosheets with O-terminated {111} facets by mild solvothermal reduction using ethylene glycol under alkaline condition. As-prepared defect-rich Co 3O 4 nanosheets show a low overpotential of 220 mV with a small Tafel slope of 49.1 mV dec -1 for the oxygen evolution reaction (OER), which is among the best Co-based OERmore » catalysts to date and even more active than the state-of-the-art IrO 2 catalyst. Such vacancy defects are formed by balancing with reducing environments under solvothermal conditions, but are surprisingly stable even after 1000 cycles of scanning under OER working conditions. Density functional theory plus U calculation attributes the enhanced performance to the oxygen vacancies and consequently exposed second-layered Co metal sites, which leads to the lowered OER activation energy of 2.26 eV and improved electrical conductivity. Finally, this mild solvothermal reduction concept opens a new door for the understanding and future designing of advanced defect-based electrocatalysts.« less

  11. Surface Defects Enhanced Visible Light Photocatalytic H2 Production for Zn-Cd-S Solid Solution.

    PubMed

    Zhang, Xiaoyan; Zhao, Zhao; Zhang, Wanwan; Zhang, Guoqiang; Qu, Dan; Miao, Xiang; Sun, Shaorui; Sun, Zaicheng

    2016-02-10

    In order to investigate the defect effect on photocatalytic performance of the visible light photocatalyst, Zn-Cd-S solid solution with surface defects is prepared in the hydrazine hydrate. X-ray photoelectron spectra and photoluminescence results confirm the existence of defects, such as sulfur vacancies, interstitial metal, and Zn and Cd in the low valence state on the top surface of solid solutions. The surface defects can be effectively removed by treating with sulfur vapor. The solid solution with surface defect exhibits a narrower band gap, wider light absorption range, and better photocatalytic perfomance. The optimized solid solution with defects exhibits 571 μmol h(-1) for 50 mg photocatalyst without loading Pt as cocatalyst under visible light irradiation, which is fourfold better than that of sulfur vapor treated samples. The wavelength dependence of photocatalytic activity discloses that the enhancement happens at each wavelength within the whole absorption range. The theoretical calculation shows that the surface defects induce the conduction band minimum and valence band maximum shift downward and upward, respectively. This constructs a type I junction between bulk and surface of solid solution, which promotes the migration of photogenerated charges toward the surface of nanostructure and leads to enhanced photocatalytic activity. Thus a new method to construct highly efficient visible light photocatalysts is opened. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Magnetic resonance imaging study of eye congenital birth defects in mouse model

    PubMed Central

    Tucker, Zachary; Mongan, Maureen; Meng, Qinghang; Xia, Ying

    2017-01-01

    Purpose Embryonic eyelid closure is a well-documented morphogenetic episode in mammalian eye development. Detection of eyelid closure defect in humans is a major challenge because eyelid closure and reopen occur entirely in utero. As a consequence, congenital eye defects that are associated with failure of embryonic eyelid closure remain unknown. To fill the gap, we developed a mouse model of defective eyelid closure. This preliminary work demonstrates that the magnetic resonance imaging (MRI) approach can be used for the detection of extraocular muscle abnormalities in the mouse model. Methods Mice with either normal (Map3k1+/−) or defective (Map3k1−/−) embryonic eyelid closure were used in this study. Images of the extraocular muscles were obtained with a 9.4 T high resolution microimaging MRI system. The extraocular muscles were identified, segmented, and measured in each imaging slice using an in-house program. Results In agreement with histological findings, the imaging data show that mice with defective embryonic eyelid closure develop less extraocular muscle than normal mice. In addition, the size of the eyeballs was noticeably reduced in mice with defective embryonic eyelid closure. Conclusions We demonstrated that MRI can potentially be used for the study of extraocular muscle in the mouse model of the eye open-at-birth defect, despite the lack of specificity of muscle group provided by the current imaging resolution. PMID:28848319

  13. Single-Crystalline Ultrathin Co 3O 4 Nanosheets with Massive Vacancy Defects for Enhanced Electrocatalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cai, Zhao; Bi, Yongmin; Hu, Enyuan

    The role of vacancy defects is demonstrated to be positive in various energy-related processes. However, introducing vacancy defects into single-crystalline nanostructures with given facets and studying their defect effect on electrocatalytic properties remains a great challenge. Here this paper deliberately introduces oxygen defects into single-crystalline ultrathin Co 3O 4 nanosheets with O-terminated {111} facets by mild solvothermal reduction using ethylene glycol under alkaline condition. As-prepared defect-rich Co 3O 4 nanosheets show a low overpotential of 220 mV with a small Tafel slope of 49.1 mV dec -1 for the oxygen evolution reaction (OER), which is among the best Co-based OERmore » catalysts to date and even more active than the state-of-the-art IrO 2 catalyst. Such vacancy defects are formed by balancing with reducing environments under solvothermal conditions, but are surprisingly stable even after 1000 cycles of scanning under OER working conditions. Density functional theory plus U calculation attributes the enhanced performance to the oxygen vacancies and consequently exposed second-layered Co metal sites, which leads to the lowered OER activation energy of 2.26 eV and improved electrical conductivity. Finally, this mild solvothermal reduction concept opens a new door for the understanding and future designing of advanced defect-based electrocatalysts.« less

  14. New spherical optical cavities with non-degenerated whispering gallery modes

    NASA Astrophysics Data System (ADS)

    Kumagai, Tsutaru; Palma, Giuseppe; Prudenzano, Francesco; Kishi, Tetsuo; Yano, Tetsuji

    2017-02-01

    New spherical resonators with internal defects are introduced to show anomalous whispering gallery modes (WGMs). The defect induces a symmetry breaking spherical cavity and splits the WGMs. A couple of defects, a hollow sphere (bubble), and a hollow ring, have been studied. The hollow sphere was fabricated and the splitting of WGM was observed. In this paper, this "non-degenerated WGMs (non-DWGMs) resonance" in a microsphere with hollow defect structure is reviewed based on our research. The resonance of WGMs in a sphere is identified by three integer parameters: the angular mode number, l, azimuthal mode number m, and radial mode number, n. The placement of the defect such as a hollow ring or single bubble is shown to break symmetry and resolve the degeneracy concerning m. This induces a variety of resonant wavelengths of the spherical cavity. A couple of simulations using the eigenmode and transient analyses propose how the placed defects affect the WGM resonance in the spherical cavity. For the sphere with a single bubble defect, the experimentally observed resonances in Nd-doped tellurite glass microsphere with a single bubble are clarified to be due to the splitting of resonance modes, i.e., the existence of "non-DWGMs" in the sphere. The defect bubble plays a role of opening the optically wide gate to introduce excitation light for Nd3+ pumping using non-DWGMs in the sphere efficiently.

  15. Automatic classification of blank substrate defects

    NASA Astrophysics Data System (ADS)

    Boettiger, Tom; Buck, Peter; Paninjath, Sankaranarayanan; Pereira, Mark; Ronald, Rob; Rost, Dan; Samir, Bhamidipati

    2014-10-01

    Mask preparation stages are crucial in mask manufacturing, since this mask is to later act as a template for considerable number of dies on wafer. Defects on the initial blank substrate, and subsequent cleaned and coated substrates, can have a profound impact on the usability of the finished mask. This emphasizes the need for early and accurate identification of blank substrate defects and the risk they pose to the patterned reticle. While Automatic Defect Classification (ADC) is a well-developed technology for inspection and analysis of defects on patterned wafers and masks in the semiconductors industry, ADC for mask blanks is still in the early stages of adoption and development. Calibre ADC is a powerful analysis tool for fast, accurate, consistent and automatic classification of defects on mask blanks. Accurate, automated classification of mask blanks leads to better usability of blanks by enabling defect avoidance technologies during mask writing. Detailed information on blank defects can help to select appropriate job-decks to be written on the mask by defect avoidance tools [1][4][5]. Smart algorithms separate critical defects from the potentially large number of non-critical defects or false defects detected at various stages during mask blank preparation. Mechanisms used by Calibre ADC to identify and characterize defects include defect location and size, signal polarity (dark, bright) in both transmitted and reflected review images, distinguishing defect signals from background noise in defect images. The Calibre ADC engine then uses a decision tree to translate this information into a defect classification code. Using this automated process improves classification accuracy, repeatability and speed, while avoiding the subjectivity of human judgment compared to the alternative of manual defect classification by trained personnel [2]. This paper focuses on the results from the evaluation of Automatic Defect Classification (ADC) product at MP Mask Technology Center (MPMask). The Calibre ADC tool was qualified on production mask blanks against the manual classification. The classification accuracy of ADC is greater than 95% for critical defects with an overall accuracy of 90%. The sensitivity to weak defect signals and locating the defect in the images is a challenge we are resolving. The performance of the tool has been demonstrated on multiple mask types and is ready for deployment in full volume mask manufacturing production flow. Implementation of Calibre ADC is estimated to reduce the misclassification of critical defects by 60-80%.

  16. Defective Store-Operated Calcium Entry Causes Partial Nephrogenic Diabetes Insipidus.

    PubMed

    Mamenko, Mykola; Dhande, Isha; Tomilin, Viktor; Zaika, Oleg; Boukelmoune, Nabila; Zhu, Yaming; Gonzalez-Garay, Manuel L; Pochynyuk, Oleh; Doris, Peter A

    2016-07-01

    Store-operated calcium entry (SOCE) is the mechanism by which extracellular signals elicit prolonged intracellular calcium elevation to drive changes in fundamental cellular processes. Here, we investigated the role of SOCE in the regulation of renal water reabsorption, using the inbred rat strain SHR-A3 as an animal model with disrupted SOCE. We found that SHR-A3, but not SHR-B2, have a novel truncating mutation in the gene encoding stromal interaction molecule 1 (STIM1), the endoplasmic reticulum calcium (Ca(2+)) sensor that triggers SOCE. Balance studies revealed increased urine volume, hypertonic plasma, polydipsia, and impaired urinary concentrating ability accompanied by elevated circulating arginine vasopressin (AVP) levels in SHR-A3 compared with SHR-B2. Isolated, split-open collecting ducts (CD) from SHR-A3 displayed decreased basal intracellular Ca(2+) levels and a major defect in SOCE. Consequently, AVP failed to induce the sustained intracellular Ca(2+) mobilization that requires SOCE in CD cells from SHR-A3. This effect decreased the abundance of aquaporin 2 and enhanced its intracellular retention, suggesting impaired sensitivity of the CD to AVP in SHR-A3. Stim1 knockdown in cultured mpkCCDc14 cells reduced SOCE and basal intracellular Ca(2+) levels and prevented AVP-induced translocation of aquaporin 2, further suggesting the effects in SHR-A3 result from the expression of truncated STIM1. Overall, these results identify a novel mechanism of nephrogenic diabetes insipidus and uncover a role of SOCE in renal water handling. Copyright © 2016 by the American Society of Nephrology.

  17. Positron Annihilation Spectroscopy and Small Angle Neutron Scattering Characterization of Nanostructural Features in Irradiated Fe-Cu-Mn Alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wirth, B D; Asoka-Kumar, P; Howell, R H

    2001-01-01

    Radiation embrittlement of nuclear reactor pressure vessel steels results from a high number density of nanometer sized Cu-Mn-Ni rich precipitates (CRPs) and sub-nanometer matrix features, thought to be vacancy-solute cluster complexes (VSC). However, questions exist regarding both the composition of the precipitates and the defect character and composition of the matrix features. We present results of positron annihilation spectroscopy (PAS) and small angle neutron scattering (SANS) characterization of irradiated and thermally aged Fe-Cu and Fe-Cu-Mn alloys. These complementary techniques provide insight into the composition and character of both types of nanoscale features. The SANS measurements indicate populations of CRPs andmore » VSCs in both alloys. The CRPs are coarser in the Fe-Cu alloy and the number densities of CRP and VSC increase with the addition of Mn. The PAS involved measuring both the positron lifetimes and the Doppler broadened annihilation spectra in the high momentum region to provide elemental sensitivity at the annihilation site. The spectra in Fe-Cu-Mn specimens thermally aged to peak hardness at 450 C and irradiated at 288 C are nearly identical to elemental Cu. Positron lifetime and spectrum measurements in Fe-Cu specimens irradiated at 288 C clearly show the existence of long lifetime ({approx}500 ps) open volume defects, which also contain Cu. Thus the SANS and PAS provide a self-consistent picture of nanostructures composed of CRPs and VSCs and tend to discount high Fe concentrations in the CRPs.« less

  18. Alarm!!! A UFO inside the heart.

    PubMed

    Santoro, Giuseppe; Castaldi, Biagio; Iacono, Carola; Giugno, Luca; Gaio, Gianpiero; Russo, Maria G

    2012-10-01

    An 8-year-old asymptomatic child was referred for surgical repair of coronary sinus atrial septal defect resulting in significant left-to-right shunt and right chamber volume overload. The septal fenestration was located near to its drainage site into the right atrium. Due to this seemingly favourable anatomy, transcatheter closure of the septal defect was performed using an Amplatzer Septal Occluder device. The echocardiographic postprocedural evaluation imaged the occluding device almost perpendicular to the atrial septum, seemingly floating above the mitral valve orifice, like an alien spaceship inside the heart.

  19. Defect reduction of high-density full-field patterns in jet and flash imprint lithography

    NASA Astrophysics Data System (ADS)

    Singh, Lovejeet; Luo, Kang; Ye, Zhengmao; Xu, Frank; Haase, Gaddi; Curran, David; LaBrake, Dwayne; Resnick, Douglas; Sreenivasan, S. V.

    2011-04-01

    Imprint lithography has been shown to be an effective technique for replication of nano-scale features. Jet and Flash Imprint Lithography (J-FIL) involves the field-by-field deposition and exposure of a low viscosity resist deposited by jetting technology onto the substrate. The patterned mask is lowered into the fluid which then quickly flows into the relief patterns in the mask by capillary action. Following this filling step, the resist is crosslinked under UV radiation, and then the mask is removed leaving a patterned resist on the substrate. Acceptance of imprint lithography for manufacturing will require demonstration that it can attain defect levels commensurate with the defect specifications of high end memory devices. Typical defectivity targets are on the order of 0.10/cm2. This work summarizes the results of defect inspections focusing on two key defect types; random non-fill defects occurring during the resist filling process and repeater defects caused by interactions with particles on the substrate. Non-fill defectivity must always be considered within the context of process throughput. The key limiting throughput step in an imprint process is resist filling time. As a result, it is critical to characterize the filling process by measuring non-fill defectivity as a function of fill time. Repeater defects typically have two main sources; mask defects and particle related defects. Previous studies have indicated that soft particles tend to cause non-repeating defects. Hard particles, on the other hand, can cause either resist plugging or mask damage. In this work, an Imprio 500 twenty wafer per hour (wph) development tool was used to study both defect types. By carefully controlling the volume of inkjetted resist, optimizing the drop pattern and controlling the resist fluid front during spreading, fill times of 1.5 seconds were achieved with non-fill defect levels of approximately 1.2/cm2. Longevity runs were used to study repeater defects and a nickel contamination was identified as the key source of particle induced repeater defects.

  20. [Cartilage regeneration surgery on the hip : What is feasible?

    PubMed

    Landgraeber, Stefan; Jäger, Marcus; Fickert, Stefan

    2017-11-01

    Localized cartilage defects at the hip are mainly caused by pre-arthritic deformities, particularly by cam-type femoroacetabular impingement (FAI). Timely elimination of symptomatic deformities can prevent further progression such as cartilage defects. As the defects mostly occur in the anterolateral part of the acetabulum, they can be easily treated either by open surgery or by arthroscopy. To date the most effective methods of treatment are bone marrow stimulation, with or without a covering of biomaterials, and autologous chondrocyte transplantation. In selected cases, readaptation of the damaged cartilage can be attempted by biological procedures. In the present article, the findings reported in current studies on these procedures are summarized and discussed in detail. An outlook is given regarding possible future treatment concepts.

  1. Single nickel-related defects in molecular-sized nanodiamonds for multicolor bioimaging: an ab initio study.

    PubMed

    Thiering, Gergő; Londero, Elisa; Gali, Adam

    2014-10-21

    Fluorescent nanodiamonds constitute an outstanding alternative to semiconductor quantum dots and dye molecules for in vivo biomarker applications, where the fluorescence comes from optically active point defects acting as color centers in the nanodiamonds. For practical purposes, these color centers should be photostable as a function of the laser power or the surface termination of nanodiamonds. Furthermore, they should exhibit a sharp and nearly temperature-independent zero-phonon line. In this study, we show by hybrid density functional theory calculations that nickel doped nanodiamonds exhibit the desired properties, thus opening the avenue to practical applications. In particular, harnessing the strong quantum confinement effect in molecule-sized nanodiamonds is very promising for achieving multicolor imaging by single nickel-related defects.

  2. Single nickel-related defects in molecular-sized nanodiamonds for multicolor bioimaging: an ab initio study

    NASA Astrophysics Data System (ADS)

    Thiering, Gergő; Londero, Elisa; Gali, Adam

    2014-09-01

    Fluorescent nanodiamonds constitute an outstanding alternative to semiconductor quantum dots and dye molecules for in vivo biomarker applications, where the fluorescence comes from optically active point defects acting as color centers in the nanodiamonds. For practical purposes, these color centers should be photostable as a function of the laser power or the surface termination of nanodiamonds. Furthermore, they should exhibit a sharp and nearly temperature-independent zero-phonon line. In this study, we show by hybrid density functional theory calculations that nickel doped nanodiamonds exhibit the desired properties, thus opening the avenue to practical applications. In particular, harnessing the strong quantum confinement effect in molecule-sized nanodiamonds is very promising for achieving multicolor imaging by single nickel-related defects.

  3. Electrical properties of graphene film for counter electrode in dye sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Khalifa, Ali; Shafie, S.; Hasan, W. Z. W.; Lim, H. N.; Rusop, M.; Samaila, Buda

    2018-05-01

    A graphene counter electrode for dye-sensitized solar cell was prepared simply by drop casting method on a conducting FTO glass at room temperature. Raman spectroscopy was used to study the defection in the graphene films. The sheet resistance was also measured and recoded minimum value of 7.04 Ω/□ at 22.19µm thickness. The casted films show good adhesion to substrates with low defects. A DSSC based on graphene counter electrode demonstrates reasonable conversion efficiency of 2.78% with short circuit current of 7.60mA, open circuit voltage of 0.69V and fill factor of 0.52. The high conductivity and low defects render the prepared graphene dispersion for DSSCs' CE application.

  4. Long palatal connective tissue rolled pedicle graft with demineralized freeze-dried bone allograft plus platelet-rich fibrin combination: A novel technique for ridge augmentation - Three case reports

    PubMed Central

    Reddy, Pathakota Krishnajaneya; Bolla, Vijayalakshmi; Koppolu, Pradeep; Srujan, Peruka

    2015-01-01

    Replacement of missing maxillary anterior tooth with localized residual alveolar ridge defect is challenging, considering the high esthetic demand. Various soft and hard tissue procedures were proposed to correct alveolar ridge deformities. Novel techniques have evolved in treating these ridge defects to improve function and esthetics. In the present case reports, a novel technique using long palatal connective tissue rolled pedicle graft with demineralized freeze-dried bone allografts (DFDBAs) plus Platelet-rich fibrin (PRF) combination was proposed to correct the Class III localized anterior maxillary anterior alveolar ridge defect. The present technique resulted in predictable ridge augmentation, which can be attributed to the soft and hard tissue augmentation with a connective tissue pedicle and DFDBA plus PRF combination. This technique suggests a variation in roll technique with DFDBA plus PRF and appears to promise in gaining predictable volume in the residual ridge defect and can be considered for the treatment of moderate to severe maxillary anterior ridge defects. PMID:26015679

  5. Compound refractive X-ray lens

    DOEpatents

    Nygren, David R.; Cahn, Robert; Cederstrom, Bjorn; Danielsson, Mats; Vestlund, Jonas

    2000-01-01

    An apparatus and method for focusing X-rays. In one embodiment, his invention is a commercial-grade compound refractive X-ray lens. The commercial-grade compound refractive X-ray lens includes a volume of low-Z material. The volume of low-Z material has a first surface which is adapted to receive X-rays of commercially-applicable power emitted from a commercial-grade X-ray source. The volume of low-Z material also has a second surface from which emerge the X-rays of commercially-applicable power which were received at the first surface. Additionally, the commercial-grade compound refractive X-ray lens includes a plurality of openings which are disposed between the first surface and the second surface. The plurality of openings are oriented such that the X-rays of commercially-applicable power which are received at the first surface, pass through the volume of low-Z material and through the plurality openings. In so doing, the X-rays which emerge from the second surface are refracted to a focal point.

  6. [Percutaneous intervention in the correction of congenital heart deffects (DCC): experience in as UMAE].

    PubMed

    Campos-García, Vicente; Ordóñez-Toquero, Guillermo; Monjaraz-Rodríguez, Sarain; Gómez-Conde, Eduardo

    Congenital heart defects are common in infants and adults, affecting quality of life if not corrected. Unlike open surgery, percutaneous intervention allows correction with a high success rate and speedy recovery. In Mexico, there are not enough studies to describe their efficacy and safety. A cohort study was conducted in the Hospital "Manuel Avila Camacho", in Puebla, Mexico, including 149 patients with congenital heart defects repaired by percutaneous intervention, recording data from clinical records. The following were documented: post-guided fluoroscopy, hemodynamic changes, cardiac catheterization drilling anatomical changes, and complications six months later such as infection or bleeding at the puncture site, device migration, endocarditis, or death. SPSS was used, using descriptive and inferential statistics. The patients' congenital heart defects treated were ductus arteriosus, atrial septal defect, and aortic coarctation, with ductus arteriosus being recorded as the most frequent congenital heart defect. Primary angioplasties were performed in 75% and stenting in the rest. Anatomical corrections of congenital defects were successful in 96.4% of patients (p < 0.01), with minimal adverse effects (p < 0.01). We conclude that our hospital has good efficacy and safety in percutaneous intervention, comparable to published reports.

  7. Numerical study of metal oxide hetero-junction solar cells with defects and interface states

    NASA Astrophysics Data System (ADS)

    Zhu, Le; Shao, Guosheng; Luo, J. K.

    2013-05-01

    Further to our previous work on ideal metal oxide (MO) hetero-junction solar cells, a systematic simulation has been carried out to investigate the effects of defects and interface states on the cells. Two structures of the window/absorber (WA) and window/absorber/voltage-enhancer (WAV) were modelled with defect concentration, defect energy level, interface state (ISt) density and ISt energy level as parameters. The simulation showed that the defects in the window layer and the voltage-enhancer layer have very limited effects on the performance of the cells, but those in the absorption layer have profound effects on the cell performance. The interface states at the W/A interface have a limited effect on the performance even for a density up to 1013 cm-2, while those at the A/V interface cause the solar cell to deteriorate severely even at a low density of lower than 1 × 1011 cm-2. It also showed that the back surface field (BSF) induced by band gap off-set in the WAV structure loses its function when defects with a modest concentration exist in the absorption layer and does not improve the open voltage at all.

  8. Three-dimensional imaging of individual point defects using selective detection angles in annular dark field scanning transmission electron microscopy.

    PubMed

    Johnson, Jared M; Im, Soohyun; Windl, Wolfgang; Hwang, Jinwoo

    2017-01-01

    We propose a new scanning transmission electron microscopy (STEM) technique that can realize the three-dimensional (3D) characterization of vacancies, lighter and heavier dopants with high precision. Using multislice STEM imaging and diffraction simulations of β-Ga 2 O 3 and SrTiO 3 , we show that selecting a small range of low scattering angles can make the contrast of the defect-containing atomic columns substantially more depth-dependent. The origin of the depth-dependence is the de-channeling of electrons due to the existence of a point defect in the atomic column, which creates extra "ripples" at low scattering angles. The highest contrast of the point defect can be achieved when the de-channeling signal is captured using the 20-40mrad detection angle range. The effect of sample thickness, crystal orientation, local strain, probe convergence angle, and experimental uncertainty to the depth-dependent contrast of the point defect will also be discussed. The proposed technique therefore opens new possibilities for highly precise 3D structural characterization of individual point defects in functional materials. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Wafer plane inspection for advanced reticle defects

    NASA Astrophysics Data System (ADS)

    Nagpal, Rajesh; Ghadiali, Firoz; Kim, Jun; Huang, Tracy; Pang, Song

    2008-05-01

    Readiness of new mask defect inspection technology is one of the key enablers for insertion & transition of the next generation technology from development into production. High volume production in mask shops and wafer fabs demands a reticle inspection system with superior sensitivity complemented by a low false defect rate to ensure fast turnaround of reticle repair and defect disposition (W. Chou et al 2007). Wafer Plane Inspection (WPI) is a novel approach to mask defect inspection, complementing the high resolution inspection capabilities of the TeraScanHR defect inspection system. WPI is accomplished by using the high resolution mask images to construct a physical mask model (D. Pettibone et al 1999). This mask model is then used to create the mask image in the wafer aerial plane. A threshold model is applied to enhance the inspectability of printing defects. WPI can eliminate the mask restrictions imposed on OPC solutions by inspection tool limitations in the past. Historically, minimum image restrictions were required to avoid nuisance inspection stops and/or subsequent loss of sensitivity to defects. WPI has the potential to eliminate these limitations by moving the mask defect inspections to the wafer plane. This paper outlines Wafer Plane Inspection technology, and explores the application of this technology to advanced reticle inspection. A total of twelve representative critical layers were inspected using WPI die-to-die mode. The results from scanning these advanced reticles have shown that applying WPI with a pixel size of 90nm (WPI P90) captures all the defects of interest (DOI) with low false defect detection rates. In validating CD predictions, the delta CDs from WPI are compared against Aerial Imaging Measurement System (AIMS), where a good correlation is established between WPI and AIMSTM.

  10. Micro-CT evaluation of bone defects: applications to osteolytic bone metastases, bone cysts, and fracture.

    PubMed

    Buie, Helen R; Bosma, Nick A; Downey, Charlene M; Jirik, Frank R; Boyd, Steven K

    2013-11-01

    Bone defects can occur in various forms and present challenges to performing a standard micro-CT evaluation of bone quality because most measures are suited to homogeneous structures rather than ones with spatially focal abnormalities. Such defects are commonly associated with pain and fragility. Research involving bone defects requires quantitative approaches to be developed if micro-CT is to be employed. In this study, we demonstrate that measures of inter-microarchitectural bone spacing are sensitive to the presence of focal defects in the proximal tibia of two distinctly different mouse models: a burr-hole model for fracture healing research, and a model of osteolytic bone metastases. In these models, the cortical and trabecular bone compartments were both affected by the defect and were, therefore, evaluated as a single unit to avoid splitting the defects into multiple analysis regions. The burr-hole defect increased mean spacing (Sp) by 27.6%, spacing standard deviation (SpSD) by 113%, and maximum spacing (Spmax) by 72.8%. Regression modeling revealed SpSD (β=0.974, p<0.0001) to be a significant predictor of the defect volume (R(2)=0.949) and Spmax (β=0.712, p<0.0001) and SpSD (β=0.271, p=0.022) to be significant predictors of the defect diameter (R(2)=0.954). In the mice with osteolytic bone metastases, spacing parameters followed similar patterns of change as reflected by other imaging technologies, specifically bioluminescence data which is indicative of tumor burden. These data highlight the sensitivity of spacing measurements to bone architectural abnormalities from 3D micro-CT data and provide a tool for quantitative evaluation of defects within a bone. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Use of a continual sweep motion to compare air polishing devices, powders and exposure time on unexposed root cementum.

    PubMed

    Herr, Mandy L; DeLong, Ralph; Li, Yuping; Lunos, Scott A; Stoltenberg, Jill L

    2017-07-01

    Low abrasive air polishing powders are a viable method for subgingival biofilm removal. This in vitro study evaluated the effects of air polishing using a standard tip on cementum following clinically recommended protocols. Forty-eight teeth were randomly divided into eight groups with six teeth per group. Teeth were treated using either a Hu-Friedy EMS or DENTSPLY Cavitron ® air polishing device. One of three glycine powders (Air-flow 25 µm, Clinpro 45 μm, Clinpro+TCP 45 μm) or a sodium bicarbonate powder (NaHCO 3  85 μm) was sprayed on cementum using a clinically relevant sweeping motion. Volume and depth of cementum removed after 5 and 90 s exposures were calculated. Surface texture was evaluated using SEMs taken following the last exposure. After 5 s exposures, neither unit nor powder had a substantial effect on volume loss or defect depth. After 90 s exposures, differences between powders existed only for the DENTSPLY unit (p < 0.0001). Pairwise comparisons for this unit revealed mean volume loss and maximum defect depth were greater for NaHCO 3 85 μm than the glycine powders (p < 0.0001). The 90 s exposure produced greater mean volume loss and defect depth for all powders (p < 0.0001). SEM images revealed dentinal tubule exposure with all powders; however, exposed tubules were larger and more prevalent for NaHCO 3 85 μm. Root surface loss was similar for glycine powders evaluated in this study. Differences in powder performance between units may be related to tip apertures and spray patterns. Additional research is needed to determine if cementum loss is greater than what occurs with conventional biofilm removal methods, such as curets and ultrasonic scalers.

  12. Arthroscopic Revision Surgery for Failure of Open Latarjet Technique.

    PubMed

    Cuéllar, Adrián; Cuéllar, Ricardo; de Heredia, Pablo Beltrán

    2017-05-01

    To evaluate the efficacy in treating pain, limited range of motion, and continued instability of the Latarjet open technique via the use of arthroscopy. A retrospective review of patients who underwent arthroscopic capsule plication after failure of an open Latarjet technique was performed. Revision surgery was indicated in cases of recurrent instability and associated pain. Only patients with a glenoid defect <25% were considered. The Constant and Rowe scores were administered, whereas pain was assessed with a visual analog scale before the reoperation and at 24 months after operation. Radiographs, computed tomography, and CT arthrography scans were performed. Twelve patients met the inclusion criteria. All patients had capsular distension and consequently were subjected to a capsuloplasty. Shoulder function, stability, and pain had all improved significantly at 24 months after arthroscopic revision (P < .0001). In particular, the Constant score increased from 44.9 (standard deviation [SD] 7.10) to 89.3 (SD 12.6) points, the Rowe score improved from 49.5 (SD 10.1) to 80.9 (SD 10.9), whereas the visual analog scale pain score decreased from 6.75 (SD 1.17) to 1.38 (SD 1.06). Primary open Latarjet with a glenoid bone defect <25% that failed due to capsular redundancy is amenable to successful treatment with arthroscopic capsuloplasty. Arthroscopic approaches can offer a good solution for treating previously failed open Latarjet procedures. Level IV, therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Probing Sub-atomistic Free-Volume Imperfections in Dry-Milled Nanoarsenicals with PAL Spectroscopy.

    PubMed

    Shpotyuk, Oleh; Ingram, Adam; Bujňáková, Zdenka; Baláž, Peter; Shpotyuk, Yaroslav

    2016-12-01

    Structural transformations caused by coarse-grained powdering and fine-grained mechanochemical milling in a dry mode were probed in high-temperature modification of tetra-arsenic tetra-sulfide known as β-As4S4. In respect to X-ray diffraction analysis, the characteristic sizes of β-As4S4 crystallites in these coarse- and fine-grained powdered pellets were 90 and 40 nm, respectively. Positron annihilation lifetime spectroscopy was employed to characterize transformations occurred in free-volume structure of these nanoarsenicals. Experimentally measured positron lifetime spectra were parameterized in respect to three- or two-term fitting procedures and respectively compared with those accumulated for single crystalline realgar α-As4S4 polymorph. The effect of coarse-grained powdering was found to result in generation of large amount of positron and positronium Ps trapping sites inside arsenicals in addition to existing ones. In fine-grained powdered β-As4S4 pellets, the positron trapping sites with characteristic free volumes close to bi- and tri-atomic vacancies were evidently dominated. These defects were supposed to originate from grain boundary regions and interfacial free volumes near aggregated β-As4S4 crystallites. Thus, the cumulative production of different positron traps with lifetimes close to defect-related lifetimes in realgar α-As4S4 polymorph was detected in fine-grained milled samples.

  14. Incubator weaning in preterm infants and associated practice variation.

    PubMed

    Schneiderman, R; Kirkby, S; Turenne, W; Greenspan, J

    2009-08-01

    To evaluate the relationship of weight of preterm infants when first placed into an open crib with days to full oral feedings, growth velocity and length of stay (LOS), and to identify unwarranted variation in incubator weaning after adjusting for severity indices. A retrospective study using the ParadigmHealth neonatal database from 2003 to 2006 reviewed incubator weaning to an open crib in appropriate-for-gestational-age (AGA) infants from 22 to weeks gestation. Primary outcome measurements included days to full oral (PO) feeding, weight gain from open crib to discharge and length of stay. Models were severity adjusted. To understand hospital practice variation, we also used a regression model to estimate the weight at open crib for the top 10 volume hospitals. In all 2908 infants met the inclusion criteria for the study. Their mean weight at open crib was 1850 g. On average every additional 100 g an infant weighed at the open crib was associated with increased time to full PO feeding by 0.8 days, decreased weight gained per day by 1 gram and increased LOS by 0.9 days. For the top 10 volume hospitals, severity variables alone accounted for 9% of the variation in weight at open crib, whereas the hospital in which the baby was treated accounted for an additional 19% of the variation. Even after controlling for severity, significant practice variation exists in weaning to an open crib, leading to potential delays in achieving full-volume oral feeds, decreased growth velocity and prolonged LOS.

  15. Magnitude of Myocutaneous Flaps and Factors Associated With Loss of Volume in Oral Cancer Reconstructive Surgery.

    PubMed

    Sakamoto, Yuki; Yanamoto, Souichi; Ota, Yoshihide; Furudoi, Shungo; Komori, Takahide; Umeda, Masahiro

    2016-03-01

    Myocutaneous flaps are often used to repair oral and maxillofacial defects after surgery for oral cancer; however, their volume decreases during the postoperative period. To facilitate treatment planning, the authors measured the extent of such postoperative flap volume loss and identified associated factors in patients who underwent oral reconstruction with myocutaneous flaps. The authors designed and performed a retrospective observational study of patients who underwent reconstructive procedures involving rectus abdominal myocutaneous (RAM) or pectoralis major myocutaneous (PMMC) flaps at Tokai University Hospital, Kobe University Hospital, or Nagasaki University Hospital from April 2009 through March 2013. Flap type and other clinical variables were examined as potential predictors of flap loss. The primary outcome was flap loss at 6 months postoperatively. Correlations between each potential predictor and the primary outcome were examined using multiple regression analysis. The subjects were 75 patients whose oral defects were reconstructed with RAM flaps (n = 57) or PMMC flaps (n = 18). RAM flaps exhibited a mean volume shrinkage of 22% at 6 months postoperatively, which was less than the 27.5% displayed by the PMMC flaps, but the difference was not important. Renal failure, previous surgery of the oral region, postoperative radiotherapy, and postoperative serum albumin level were found to be meaningful risk factors for postoperative flap volume loss. The results of this study suggest that larger flaps should be used in patients who possess these risk factors or are scheduled to undergo postoperative radiotherapy. Future studies should examine the utility of postoperative nutritional management for preventing flap volume loss. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Negative pressure wound therapy for the treatment of infected wounds with exposed knee joint after patellar fracture.

    PubMed

    Lee, Sang Yang; Niikura, Takahiro; Miwa, Masahiko; Sakai, Yoshitada; Oe, Keisuke; Fukazawa, Takahiro; Kawakami, Yohei; Kurosaka, Masahiro

    2011-06-14

    Treatment of soft tissue defects with exposed bones and joints, resulting from trauma, infection, and surgical complications, represents a major challenge. The introduction of negative pressure wound therapy has changed many wound management practices. Negative pressure wound therapy has recently been used in the orthopedic field for management of traumatic or open wounds with exposed bone, nerve, tendon, and orthopedic implants. This article describes a case of a patient with a large soft tissue defect and exposed knee joint, in which negative pressure wound therapy markedly improved wound healing. A 50-year-old man presented with an ulceration of his left knee with exposed joint, caused by severe wound infections after open reduction and internal fixation of a patellar fracture. After 20 days of negative pressure wound therapy, a granulated wound bed covered the exposed bones and joint.To our knowledge, this is the first report of negative pressure wound therapy used in a patient with a large soft tissue defect with exposed knee joint. Despite the chronic wound secondary to infection, healing was achieved through the use of the negative pressure wound therapy, thus promoting granulation tissue formation and closing the joint. We suggest negative pressure wound therapy as an alternative option for patients with lower limb wounds containing exposed bones and joints when free flap transfer is contraindicated. Our result added to the growing evidence that negative pressure wound therapy is a useful adjunctive treatment for open wounds around the knee joint. Copyright 2011, SLACK Incorporated.

  17. Improvement of Railroad Roller Bearing Test Procedures & Development of Roller Bearing Diagnostic Techniques. Volume 2.

    DOT National Transportation Integrated Search

    1982-04-01

    A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...

  18. III/V nano ridge structures for optical applications on patterned 300 mm silicon substrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunert, B.; Guo, W.; Mols, Y.

    We report on an integration approach of III/V nano ridges on patterned silicon (Si) wafers by metal organic vapor phase epitaxy (MOVPE). Trenches of different widths (≤500 nm) were processed in a silicon oxide (SiO{sub 2}) layer on top of a 300 mm (001) Si substrate. The MOVPE growth conditions were chosen in a way to guarantee an efficient defect trapping within narrow trenches and to form a box shaped ridge with increased III/V volume when growing out of the trench. Compressively strained InGaAs/GaAs multi-quantum wells with 19% indium were deposited on top of the fully relaxed GaAs ridges as an activemore » material for optical applications. Transmission electron microcopy investigation shows that very flat quantum well (QW) interfaces were realized. A clear defect trapping inside the trenches is observed whereas the ridge material is free of threading dislocations with only a very low density of planar defects. Pronounced QW photoluminescence (PL) is detected from different ridge sizes at room temperature. The potential of these III/V nano ridges for laser integration on Si substrates is emphasized by the achieved ridge volume which could enable wave guidance and by the high crystal quality in line with the distinct PL.« less

  19. Structural Defects in Donor-Acceptor Blends: Influence on the Performance of Organic Solar Cells

    NASA Astrophysics Data System (ADS)

    Sergeeva, Natalia; Ullbrich, Sascha; Hofacker, Andreas; Koerner, Christian; Leo, Karl

    2018-02-01

    Defects play an important role in the performance of organic solar cells. The investigation of trap states and their origin can provide ways to further improve their performance. Here, we investigate defects in a system composed of the small-molecule oligothiophene derivative DCV5T-Me blended with C60 , which shows power conversion efficiencies above 8% when used in a solar cell. From a reconstruction of the density of trap states by impedance spectroscopy, we obtain a Gaussian distribution of trap states with Et=470 meV below the electron transport level, Nt=8 ×1014 cm-3 , and σt=41 meV . From Voc vs illumination intensity and open-circuit corrected charge carrier extraction measurements, we find that these defects lead to trap-assisted recombination. Moreover, drift-diffusion simulations show that the trap states decrease the fill factor by 10%. By conducting degradation measurements and varying the blend ratio, we find that the observed trap states are structural defects in the C60 phase due to the distortion of the natural morphology induced by the mixing.

  20. Crack initiation and potential hot-spot formation around a cylindrical defect under dynamic compression

    NASA Astrophysics Data System (ADS)

    Ma, Xiao; Li, Xinguo; Zheng, Xianxu; Li, Kewu; Hu, Qiushi; Li, Jianling

    2017-11-01

    In recent decades, the hot-spot theory of condensed-phase explosives has been a compelling focus of scientific investigation attracting many researchers. The defect in the polymeric binder of the polymer-bonded explosive is called the intergranular defect. In this study, the real polymeric binder was substituted by poly(methyl methacrylate) (PMMA) as it is transparent and has similar thermodynamic properties to some binders. A set of modified split Hopkinson pressure bars equipped with a time-resolved shadowgraph was used to study the process of crack initiation and potential hot-spot formation around a cylindrical defect in PMMA. The new and significant phenomenon that the opening-mode crack emerged earlier than the shearing-mode crack from the cylindrical defect has been published for the first time in this paper. Furthermore, a two-dimensional numerical simulation was performed to show the evolution of both the stress field and the temperature field. The simulation results were in good agreement with the experiment. Finally, the law of potential hot-spot formation is discussed in detail.

  1. Channeling Excitons to Emissive Defect Sites in Carbon Nanotube Semiconductors beyond the Dilute Regime.

    PubMed

    Powell, Lyndsey R; Piao, Yanmei; Ng, Allen L; Wang, YuHuang

    2018-06-07

    The exciton photoluminescence of carbon nanotube semiconductors has been intensively exploited for bioimaging, anticounterfeiting, photodetection, and quantum information science. However, at high concentrations, photoluminescence is lost to self-quenching because of the nearly complete overlap of the absorption and emissive states (∼10 meV Stokes shift). Here we show that by introducing sparse fluorescent quantum defects via covalent chemistry, self-quenching can be efficiently bypassed by means of the new emission route. The defect photoluminescence is significantly red-shifted by 190 meV for p-nitroaryl tailored (6,5)-single-walled carbon nanotubes (SWCNTs) from the native emission of the nanotube. Notably, the defect photoluminescence is more than 34 times brighter than the native photoluminescence of unfunctionalized SWCNTs in the most concentrated nanotube solution tested (2.7 × 10 14 nanotubes/mL). Moreover, we show that defect photoluminescence is more resistant to self-quenching than the native state in a dense film, which is the upper limit of concentration. Our findings open opportunities to harness nanotube excitons in highly concentrated systems for applications where photoluminescence brightness and light-collecting efficiency are mutually important.

  2. Effect of geometric nonlinearity on acoustic modulation

    NASA Astrophysics Data System (ADS)

    Warnemuende, Kraig; Wu, Hwai-Chung

    2005-05-01

    Non-linear nondestructive testing is different from linear acoustic in that it correlates the presence and characteristics of a defect with acoustical signals whose frequencies differ from the frequencies of the emitted probe signal. The difference in frequencies between the probe signal and the resulting frequencies is due to a nonlinear transformation of the probe signal as it passes through a defect. Under acoustic interrogation due to longitudinal waves, as the compression phase passes the defect the two sides of the interface are in direct contact and the contact area increases. Similarly, the tensile phase passes through the defect, the two sides separate and the contact area decreases, thereby modulating the signal amplitude. The contact area depends on the roughness of the surface and on the magnitude of the cohesive forces that arise from the small crack openings. Such cohesive forces may be attributed to aggregate interlock (in plain concrete), fiber bridging (in fiber reinforced concrete) or both. In this paper, the frequency shifts of the probe elastic wave will be analytically related to the roughness and varying cohesive forces of the crack-like defect.

  3. Surgical Orthodontic Treatment for Open Bite in Noonan Syndrome Patient: A Case Report.

    PubMed

    Kawakami, Masayoshi; Yamamoto, Kazuhiko; Shimomura, Tadahiro; Kirita, Tadaaki

    2016-03-01

    Noonan syndrome, characterized by short stature, facial anomalies, and congenital heart defects, may also be associated with hematopoietic disorders. Craniofacial anomalies in affected patients include hypertelorism and severe open bite associated with masticatory dysfunction. We treated a Noonan syndrome patient with a skeletal open bite. Surgical orthodontic treatment including two-jaw surgery established a good occlusal relationship after correction of severe anemia. Both upper and lower incisors were moved to upright positions, while clockwise rotation of the palatal plane and decreased mandibular plane angle were accomplished. Lower masticatory activity may affect posttreatment occlusion in such cases.

  4. Selective formation of porous silicon

    NASA Technical Reports Server (NTRS)

    Fathauer, Robert W. (Inventor); Jones, Eric W. (Inventor)

    1993-01-01

    A pattern of porous silicon is produced in the surface of a silicon substrate by forming a pattern of crystal defects in said surface, preferably by applying an ion milling beam through openings in a photoresist layer to the surface, and then exposing said surface to a stain etchant, such as HF:HNO3:H2O. The defected crystal will preferentially etch to form a pattern of porous silicon. When the amorphous content of the porous silicon exceeds 70 percent, the porous silicon pattern emits visible light at room temperature.

  5. Investigation of welded joints of aluminium alloys using subminiature eddy-current transducers

    NASA Astrophysics Data System (ADS)

    Dmitriev, S. F.; Ishkov, A. V.; Katasonov, A. O.; Malikov, V. N.; Sagalakov, A. M.

    2018-03-01

    The authors developed a measuring system based on subminiaturized eddy-current transducers aimed at examining locally the defects of welded joints in aluminium-magnesium alloy plates connected by means of friction stir welding. The authors made a modification of the Delyann filter, which allowed them to increase considerably the signal-noise relations. The dependency of the eddy-current transducer response on defects was provided, i.e. concealed cuts and openings inside the welded joint, at the frequencies of 100-10000 Hz of the exciting winding.

  6. Branchial cleft cyst

    MedlinePlus

    ... develop normally. The birth defect may appear as open spaces called cleft sinuses, which may develop on one or both sides of the neck. A branchial cleft cyst may form from fluid drained from a sinus. The cyst or sinus can become infected.

  7. Numerical simulation and optimization of casting process for complex pump

    NASA Astrophysics Data System (ADS)

    Liu, Xueqin; Dong, Anping; Wang, Donghong; Lu, Yanling; Zhu, Guoliang

    2017-09-01

    The complex shape of the casting pump body has large complicated structure and uniform wall thickness, which easy give rise to casting defects. The numerical simulation software ProCAST is used to simulate the initial top gating process, after analysis of the material and structure characteristics of the high-pressure pump. The filling process was overall smooth, not there the water shortage phenomenon. But the circular shrinkage defects appear at the bottom of casting during solidification process. Then, the casting parameters were optimized and adding cold iron in the bottom. The shrinkage weight was reduced from 0.00167g to 0.0005g. The porosity volume was reduced from 1.39cm3 to 0.41cm3. The optimization scheme is simulated and actual experimented. The defect has been significantly improved.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jin; Fan, Cuncai; Ding, Jie

    High energy particle radiations induce severe microstructural damage in metallic materials. Nanoporous materials with a giant surface-to-volume ratio may alleviate radiation damage in irradiated metallic materials as free surface are defect sinks. We show, by using in situ Kr ion irradiation in a transmission electron microscope at room temperature, that nanoporous Au indeed has significantly improved radiation tolerance comparing with coarse-grained, fully dense Au. In situ studies show that nanopores can absorb and eliminate a large number of radiation-induced defect clusters. Meanwhile, nanopores shrink (self-heal) during radiation, and their shrinkage rate is pore size dependent. Furthermore, the in situ studiesmore » show dose-rate-dependent diffusivity of defect clusters. Our study sheds light on the design of radiation-tolerant nanoporous metallic materials for advanced nuclear reactor applications.« less

  9. Water-vapor pressure control in a volume

    NASA Technical Reports Server (NTRS)

    Scialdone, J. J.

    1978-01-01

    The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

  10. Factors that influence the outcome of open urethroplasty for pelvis fracture urethral defect (PFUD): an observational study from a single high-volume tertiary care center.

    PubMed

    Fu, Qiang; Zhang, Yu-meng; Barbagli, Guido; Zhang, Jiong; Xie, Hong; Sa, Ying-long; Jin, San-bao; Xu, Yue-min

    2015-12-01

    To report the clinical features of pelvic fracture urethral injury (PFUI) and assess the real effect of factors that are believed to have adverse effects on delayed urethroplasty. An observational descriptive study in a single urological center examined 376 male patients diagnosed with PFUI who underwent open urethroplasty from 2009 to 2013. Analyzed factors included patient age at the time of injury, etiology of PFUI, type of emergency treatment, concomitant injuries, length and position of stricture, type of urethroplasty and the outcome of surgery. Univariate and multivariate logistic regression analyses were applied, together with analytical statistic methods such as t test and Chi-square test. The overall success rate of delayed urethroplasty was 80.6 %. Early realignment was associated with reduced stricture length and had beneficial effect on delayed surgery. Concomitant rectum rupture, strictures longer than 1.6 cm and strictures closer than 3 cm to the bladder neck were indicators of poor outcome. Age, type of injury, urethral fistula and bladder rupture were not significant predicators of surgery outcome. Failed direct vision internal urethrotomy and urethroplasty had no significant influence on salvage operation. The outcome of posterior urethroplasty is affected by multiple factors. Early realignment has beneficial effect; while the length and position of stricture and its distance to bladder neck plays the key role, rectum rupture at the time of injury is also an indicator of poor outcome. The effect of other factors seems insignificant.

  11. Slow Orthodontic Teeth Extrusion to Enhance Hard and Soft Periodontal Tissue Quality before Implant Positioning in Aesthetic Area

    PubMed Central

    Maiorana, C; Speroni, S; Herford, A S; Cicciù, M

    2012-01-01

    Approaching bone defects of jaws treatments, hard and soft tissue augmentation could be considered as a goal for clinicians when performing dental implant placement. The increase in patients who want cosmetic treatment puts practitioners in an awkward position when choosing the best therapy to obtain the most desirable results. A private dentist referred a young patient to the Department of Implantology in Milan in order to place implants in the upper jaw. Radiographic evaluation of the two upper anterior incisors confirmed that the teeth had a poor prognosis The anterior ridge volume was clinically analyzed and several therapeutic choices were evaluated. Rapid extractions and immediate implant positioning were not considered due to the vertical and horizontal components of the bone defect. Therefore, the surgical team decided on increasing the bone volume by using slow orthodontic teeth extrusion technique. After 3 months of orthodontic treatment, the angular intra-bony defects of 1.1 tooth was completely healed. Implant guided positioning, associated with a small bone graft, showed optimal results at the time of healing screw placement. The soft tissue conditioning was obtained by a provisional acrylic crown. The final application of two integral ceramic crowns showed excellent aesthetic results. Radiographic investigation at a 24 month follow-up confirmed the integration of the dental implants and the recovery of the bone defects. Several safe surgical techniques are available today for reconstructing atrophic jaws. However, the same technique applied on the posterior area did not give the same predictable results as in the anterior areas of the jaw. PMID:23056158

  12. A Stereological Method for the Quantitative Evaluation of Cartilage Repair Tissue

    PubMed Central

    Nyengaard, Jens Randel; Lind, Martin; Spector, Myron

    2015-01-01

    Objective To implement stereological principles to develop an easy applicable algorithm for unbiased and quantitative evaluation of cartilage repair. Design Design-unbiased sampling was performed by systematically sectioning the defect perpendicular to the joint surface in parallel planes providing 7 to 10 hematoxylin–eosin stained histological sections. Counting windows were systematically selected and converted into image files (40-50 per defect). The quantification was performed by two-step point counting: (1) calculation of defect volume and (2) quantitative analysis of tissue composition. Step 2 was performed by assigning each point to one of the following categories based on validated and easy distinguishable morphological characteristics: (1) hyaline cartilage (rounded cells in lacunae in hyaline matrix), (2) fibrocartilage (rounded cells in lacunae in fibrous matrix), (3) fibrous tissue (elongated cells in fibrous tissue), (4) bone, (5) scaffold material, and (6) others. The ability to discriminate between the tissue types was determined using conventional or polarized light microscopy, and the interobserver variability was evaluated. Results We describe the application of the stereological method. In the example, we assessed the defect repair tissue volume to be 4.4 mm3 (CE = 0.01). The tissue fractions were subsequently evaluated. Polarized light illumination of the slides improved discrimination between hyaline cartilage and fibrocartilage and increased the interobserver agreement compared with conventional transmitted light. Conclusion We have applied a design-unbiased method for quantitative evaluation of cartilage repair, and we propose this algorithm as a natural supplement to existing descriptive semiquantitative scoring systems. We also propose that polarized light is effective for discrimination between hyaline cartilage and fibrocartilage. PMID:26069715

  13. A Stereological Method for the Quantitative Evaluation of Cartilage Repair Tissue.

    PubMed

    Foldager, Casper Bindzus; Nyengaard, Jens Randel; Lind, Martin; Spector, Myron

    2015-04-01

    To implement stereological principles to develop an easy applicable algorithm for unbiased and quantitative evaluation of cartilage repair. Design-unbiased sampling was performed by systematically sectioning the defect perpendicular to the joint surface in parallel planes providing 7 to 10 hematoxylin-eosin stained histological sections. Counting windows were systematically selected and converted into image files (40-50 per defect). The quantification was performed by two-step point counting: (1) calculation of defect volume and (2) quantitative analysis of tissue composition. Step 2 was performed by assigning each point to one of the following categories based on validated and easy distinguishable morphological characteristics: (1) hyaline cartilage (rounded cells in lacunae in hyaline matrix), (2) fibrocartilage (rounded cells in lacunae in fibrous matrix), (3) fibrous tissue (elongated cells in fibrous tissue), (4) bone, (5) scaffold material, and (6) others. The ability to discriminate between the tissue types was determined using conventional or polarized light microscopy, and the interobserver variability was evaluated. We describe the application of the stereological method. In the example, we assessed the defect repair tissue volume to be 4.4 mm(3) (CE = 0.01). The tissue fractions were subsequently evaluated. Polarized light illumination of the slides improved discrimination between hyaline cartilage and fibrocartilage and increased the interobserver agreement compared with conventional transmitted light. We have applied a design-unbiased method for quantitative evaluation of cartilage repair, and we propose this algorithm as a natural supplement to existing descriptive semiquantitative scoring systems. We also propose that polarized light is effective for discrimination between hyaline cartilage and fibrocartilage.

  14. In Vivo Evaluation of 3D-Printed Polycaprolactone Scaffold Implantation Combined with β-TCP Powder for Alveolar Bone Augmentation in a Beagle Defect Model

    PubMed Central

    Park, Su A.; Lee, Hyo-Jung; Kim, Keun-Suh; Lee, Jung-Tae; Kim, Sung-Yeol; Chang, Na-Hee

    2018-01-01

    Insufficient bone volume is one of the major challenges encountered by dentists after dental implant placement. This study aimed to evaluate the efficacy of a customized three-dimensional polycaprolactone (3D PCL) scaffold implant fabricated with a 3D bio-printing system to facilitate rapid alveolar bone regeneration. Saddle-type bone defects were surgically created on the healed site after extracting premolars from the mandibles of four beagle dogs. The defects were radiologically examined using computed tomography for designing a customized 3D PCL scaffold block to fit the defect site. After fabricating 3D PCL scaffolds using rapid prototyping, the scaffolds were implanted into the alveolar bone defects along with β-tricalcium phosphate powder. In vivo analysis showed that the PCL blocks maintained the physical space and bone conductivity around the defects. In addition, no inflammatory infiltrates were observed around the scaffolds. However, new bone formation occurred adjacent to the scaffolds, rather than directly in contact with them. More new bone was observed around PCL blocks with 400/1200 lattices than around blocks with 400/400 lattices, but the difference was not significant. These results indicated the potential of 3D-printed porous PCL scaffolds to promote alveolar bone regeneration for defect healing in dentistry. PMID:29401707

  15. Strain-induced structural defects and their effects on the electrochemical performances of silicon core/germanium shell nanowire heterostructures

    DOE PAGES

    Lin, Yung-Chen; Kim, Dongheun; Li, Zhen; ...

    2016-12-14

    Here we report on strain-induced structural defect formation in core Si nanowire of Si/Ge core/shell nanowire heterostructure and influences of the structural defects on the electrochemical performances in lithium-ion battery anodes based on Si/Ge core/shell nanowire heterostructures. The induced structural defects consisting of stacking faults and dislocations in the core Si nanowire were observed for the first time. The generation of stacking faults in Si/Ge core/shell nanowire heterostructure is observed to prefer settling in either only Ge shell region or in both Ge shell and Si core regions and is associated with the increase of the shell volume fraction. Themore » relax of misfit strain in [112] oriented core/shell nanowire heterostructure leads to subsequent gliding of Shockley partial dislocations, preferentially forming the twins. The observation of cross-over defect formation is of great importance for the understanding of heteroepitaxy in radial heterostructures at nanoscale and building the three dimensional heterostructures for the various applications. In addition, the effect of the defect formation on nanomaterial’s functionality is investigated by electrochemical performance test. The Si/Ge core/shell nanowire heterostructures enhance the gravimetric capacity of lithium ion battery anodes under fast charging/discharging rates compared to Si nanowires. However, the induced structural defects hamper lithiation of the Si/Ge core/shell nanowire heterostructure.« less

  16. Effect of gelatin sponge with colloid silver on bone healing in infected cranial defects.

    PubMed

    Dong, Yuliang; Liu, Weiqing; Lei, Yiling; Wu, Tingxi; Zhang, Shiwen; Guo, Yuchen; Liu, Yuan; Chen, Demeng; Yuan, Quan; Wang, Yongyue

    2017-01-01

    Oral infectious diseases may lead to bone loss, which makes it difficult to achieve satisfactory restoration. The rise of multidrug resistant bacteria has put forward severe challenges to the use of antibiotics. Silver (Ag) has long been known as a strong antibacterial agent. In clinic, gelatin sponge with colloid silver is used to reduce tooth extraction complication. To investigate how this material affect infected bone defects, methicillin-resistant Staphylococcus aureus (MRSA) infected 3-mm-diameter cranial defects were created in adult female Sprague-Dawley rats. One week after infection, the defects were debrided of all nonviable tissue and then implanted with gelatin sponge with colloid silver (gelatin/Ag group) or gelatin alone (gelatin group). At 2 and 3days after debridement, significantly lower mRNA expression levels of IL-6 and TNF-α and lower plate colony count value were detected in gelatin/Ag group than control. Micro-CT analysis showed a significant increase of newly formed bone volume fraction (BV/TV) in gelatin/Ag treated defects. The HE stained cranium sections also showed a faster rate of defect closure in gelatin/Ag group than control. These findings demonstrated that gelatin sponge with colloid silver can effectively reduce the infection caused by MRSA in cranial defects and accelerate bone healing process. Copyright © 2016. Published by Elsevier B.V.

  17. Strain-induced structural defects and their effects on the electrochemical performances of silicon core/germanium shell nanowire heterostructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Yung-Chen; Kim, Dongheun; Li, Zhen

    Here we report on strain-induced structural defect formation in core Si nanowire of Si/Ge core/shell nanowire heterostructure and influences of the structural defects on the electrochemical performances in lithium-ion battery anodes based on Si/Ge core/shell nanowire heterostructures. The induced structural defects consisting of stacking faults and dislocations in the core Si nanowire were observed for the first time. The generation of stacking faults in Si/Ge core/shell nanowire heterostructure is observed to prefer settling in either only Ge shell region or in both Ge shell and Si core regions and is associated with the increase of the shell volume fraction. Themore » relax of misfit strain in [112] oriented core/shell nanowire heterostructure leads to subsequent gliding of Shockley partial dislocations, preferentially forming the twins. The observation of cross-over defect formation is of great importance for the understanding of heteroepitaxy in radial heterostructures at nanoscale and building the three dimensional heterostructures for the various applications. In addition, the effect of the defect formation on nanomaterial’s functionality is investigated by electrochemical performance test. The Si/Ge core/shell nanowire heterostructures enhance the gravimetric capacity of lithium ion battery anodes under fast charging/discharging rates compared to Si nanowires. However, the induced structural defects hamper lithiation of the Si/Ge core/shell nanowire heterostructure.« less

  18. Automated pulmonary lobar ventilation measurements using volume-matched thoracic CT and MRI

    NASA Astrophysics Data System (ADS)

    Guo, F.; Svenningsen, S.; Bluemke, E.; Rajchl, M.; Yuan, J.; Fenster, A.; Parraga, G.

    2015-03-01

    Objectives: To develop and evaluate an automated registration and segmentation pipeline for regional lobar pulmonary structure-function measurements, using volume-matched thoracic CT and MRI in order to guide therapy. Methods: Ten subjects underwent pulmonary function tests and volume-matched 1H and 3He MRI and thoracic CT during a single 2-hr visit. CT was registered to 1H MRI using an affine method that incorporated block-matching and this was followed by a deformable step using free-form deformation. The resultant deformation field was used to deform the associated CT lobe mask that was generated using commercial software. 3He-1H image registration used the same two-step registration method and 3He ventilation was segmented using hierarchical k-means clustering. Whole lung and lobar 3He ventilation and ventilation defect percent (VDP) were generated by mapping ventilation defects to CT-defined whole lung and lobe volumes. Target CT-3He registration accuracy was evaluated using region- , surface distance- and volume-based metrics. Automated whole lung and lobar VDP was compared with semi-automated and manual results using paired t-tests. Results: The proposed pipeline yielded regional spatial agreement of 88.0+/-0.9% and surface distance error of 3.9+/-0.5 mm. Automated and manual whole lung and lobar ventilation and VDP were not significantly different and they were significantly correlated (r = 0.77, p < 0.0001). Conclusion: The proposed automated pipeline can be used to generate regional pulmonary structural-functional maps with high accuracy and robustness, providing an important tool for image-guided pulmonary interventions.

  19. Histopathologic analysis of atrial tissue in patients with atrial fibrillation: comparison between patients with atrial septal defect and patients with mitral valvular heart disease.

    PubMed

    Kwak, Jae Gun; Seo, Jeong-Wook; Oh, Sam Se; Lee, Sang Yun; Ham, Eui Keun; Kim, Woong-Han; Kim, Soo-Jin; Bae, Eun Jung; Lim, Cheoung; Lee, Chang-Ha; Lee, Cheul

    2014-01-01

    Atrial fibrillation (AF) in adult patients with atrial septal defect (ASD) accompanies an enlarged right atrium (RA) with a less enlarged left atrium (LA), which is the opposite situation in patients with AF and mitral valvular disease. This study was to compare the histopathological change in the atrium of patients with AF of two different etiologies: ASD and mitral disease. Twenty-four patients were enrolled. Group 1 included patients with ASD (8), Group 2 included patients with ASD with AF (6), and Group 3 included patients with mitral disease with AF (10). Preoperative atrial volumes were measured. Atrial tissues were obtained during surgical procedures and stained with periodic acid-Schiff, smooth muscle actin, Sirius red, and Masson's trichrome to detect histopathologic changes compatible with AF. The severity of histopathological changes was represented with "positivity" and "strong positivity" after analyzing digitalized images of the staining. We investigated the relationship between the degree of atrial dilatation and severity of histopathological changes according to the groups and tissues. Group 2 and Group 3 patients showed a tendency toward an enlarged RA volume and enlarged LA volume, respectively, compared with each others. However, in the histopathologic analysis, "positivity" and "strong positivity" showed no significant positive correlations with the degree of atrial volume in special staining. A similar degree of histopathologic changes was observed in both atria in patients with AF (Group 2 and 3) regardless of the degree of dilatation of atrial volume and disease entities. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  20. Eddy Current Testing with Giant Magnetoresistance (GMR) Sensors and a Pipe-Encircling Excitation for Evaluation of Corrosion under Insulation

    PubMed Central

    Bailey, Joseph; Hunze, Arvid

    2017-01-01

    This work investigates an eddy current-based non-destructive testing (NDT) method to characterize corrosion of pipes under thermal insulation, one of the leading failure mechanisms for insulated pipe infrastructure. Artificial defects were machined into the pipe surface to simulate the effect of corrosion wall loss. We show that by using a giant magnetoresistance (GMR) sensor array and a high current (300 A), single sinusoidal low frequency (5–200 Hz) pipe-encircling excitation scheme it is possible to quantify wall loss defects without removing the insulation or weather shield. An analysis of the magnetic field distribution and induced currents was undertaken using the finite element method (FEM) and analytical calculations. Simple algorithms to remove spurious measured field variations not associated with defects were developed and applied. The influence of an aluminium weather shield with discontinuities and dents was ascertained and found to be small for excitation frequency values below 40 Hz. The signal dependence on the defect dimensions was analysed in detail. The excitation frequency at which the maximum field amplitude change occurred increased linearly with the depth of the defect by about 3 Hz/mm defect depth. The change in magnetic field amplitude due to defects for sensors aligned in the azimuthal and radial directions were measured and found to be linearly dependent on the defect volume between 4400–30,800 mm3 with 1.2 × 10−3−1.6 × 10−3 µT/mm3. The results show that our approach is well suited for measuring wall loss defects similar to the defects from corrosion under insulation. PMID:28956855

  1. Eddy Current Testing with Giant Magnetoresistance (GMR) Sensors and a Pipe-Encircling Excitation for Evaluation of Corrosion under Insulation.

    PubMed

    Bailey, Joseph; Long, Nicholas; Hunze, Arvid

    2017-09-28

    This work investigates an eddy current-based non-destructive testing (NDT) method to characterize corrosion of pipes under thermal insulation, one of the leading failure mechanisms for insulated pipe infrastructure. Artificial defects were machined into the pipe surface to simulate the effect of corrosion wall loss. We show that by using a giant magnetoresistance (GMR) sensor array and a high current (300 A), single sinusoidal low frequency (5-200 Hz) pipe-encircling excitation scheme it is possible to quantify wall loss defects without removing the insulation or weather shield. An analysis of the magnetic field distribution and induced currents was undertaken using the finite element method (FEM) and analytical calculations. Simple algorithms to remove spurious measured field variations not associated with defects were developed and applied. The influence of an aluminium weather shield with discontinuities and dents was ascertained and found to be small for excitation frequency values below 40 Hz. The signal dependence on the defect dimensions was analysed in detail. The excitation frequency at which the maximum field amplitude change occurred increased linearly with the depth of the defect by about 3 Hz/mm defect depth. The change in magnetic field amplitude due to defects for sensors aligned in the azimuthal and radial directions were measured and found to be linearly dependent on the defect volume between 4400-30,800 mm³ with 1.2 × 10 -3 -1.6 × 10 -3 µT/mm³. The results show that our approach is well suited for measuring wall loss defects similar to the defects from corrosion under insulation.

  2. Transabdominal midline reconstruction by minimally invasive surgery: technique and results.

    PubMed

    Costa, T N; Abdalla, R Z; Santo, M A; Tavares, R R F M; Abdalla, B M Z; Cecconello, I

    2016-04-01

    The introduction of the minimally invasive approach changed the way abdominal surgery was carried out. Open suture and mesh reinforcement in ventral hernia repair used to be the surgeon's choice of procedure. Although the laparoscopic approach, with defect bridging and mesh fixation, has been described since 1993, the procedure remains largely unchanged. Evidence shows that defect closure and retro-muscular mesh positioning have the best outcomes and are the best surgical practice. We therefore aimed to develop and demonstrate a procedure which combined the good results of open surgery using the Rives-Stoppa principles, particularly in terms of recurrence, with all the benefits of minimally invasive surgery. Between October 2012 and February 2014, 15 post-bariatric surgery patients underwent laparoscopic midline incisional hernia repair. The peritoneal cavity was accessed through a 5-mm optical view cannula at the superior left quadrant. A suprapubic and two right and left lower quadrant cannulas were inserted for inferior access and dissection. The defect adhesions were released. The whole midline was closed with an endoscopic linear stapler, including the defect, from the lower abdomen, 4 cm below the umbilicus, until the epigastric region, including posterior sheath mechanical suturing and cutting in the same movement. A retrorectus space was created in which a retro-muscular mesh was deployed. Fixation was done using a hernia stapler against the posterior sheath from the peritoneal cavity to the abdominal wall muscles. Selection was based on xifo-umbilical incisional midline hernias post open bariatric surgery. Pregnant women, cancer patients, or patients with clinical contraindications were excluded. The patients mean age was 51.2 years (range 39-67). Four patients were men and eleven women. Two had well-compensated fibromyalgia, four had diabetes, and five had hypertension. The mean BMI was 29.5 kg/m2 (range 23-31.6). Surgery was performed successfully in all cases through four ports; the number of incisional hernias was 3 ± 2, with a mean maximum width of 3.75 cm (range 2.1-9) and maximum length of 14 cm (7.5-20.5). The mean surgical time was 114.3 min (range 85-170), and the median hospital stay was 1.4 days. No intra-operative or immediate post-operative complication or death occurred. One patient had a seroma treated conservatively 1 week after surgery and another had a retro-muscular infection treated with percutaneous drainage. CT-Scans made before and after the procedure, showed total closure of the defect. QOL questionnaire showed satisfaction, acceptance, and no complaints. Although the study involved a small number of patients, it has proved the technique to be feasible, easy to perform, and have the combined benefits of laparoscopic and open surgery. The results, shown by CT-scan, peri-operative, and QOL findings, were good.

  3. Analysis of the results of replacement of large bone defects in the patients who underwent segmental bone resection for tumor

    NASA Astrophysics Data System (ADS)

    Anastasieva, E. A.; Voropaeva, A. A.; Sadovoy, M. A.; Kirilova, I. A.

    2017-09-01

    The problem of large bone defects replacement, formed after segmental bone resections, remains an actual issue of modern orthopedics. It is known that the autograft is the most acceptable material for the replacement of bone tissue; however, due to its small volume and physical properties, it has limited usage. Our goal is to analyze the results of the experiments and studies on replacement of large bone defects after resection of the bone tumor. The problem is justified by the complicated osteoconduction and osteointegration; because it is proved that the reconstruction of the microcirculatory bloodstream is difficult in the presence of damage more than 4 cm2. It was revealed that using of allograft in combination with additional components is comparable in effectiveness, including long-term period, with autograft usage. It is promising to combine plastic allogenous material, capable of reconstructing defects of various configuration intraoperatively, with the necessary chemotherapy with controlled desorption to maintain effective concentration of drug.

  4. The self-healing of defects induced by the hydriding phase transformation in palladium nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ulvestad, A.; Yau, A.

    Nanosizing can dramatically alter material properties by enhancing surface thermodynamic contributions, shortening diffusion lengths, and increasing the number of catalytically active sites per unit volume. These mechanisms have been used to explain the improved properties of catalysts, battery materials, plasmonic materials, etc. Here we show that Pd nanoparticles also have the ability to self-heal defects in their crystal structures. Using Bragg coherent diffractive imaging, we image dislocations nucleated deep in a Pd nanoparticle during the forward hydriding phase transformation that heal during the reverse transformation, despite the region surrounding the dislocations remaining in the hydrogen-poor phase. We show that defectivemore » Pd nanoparticles exhibit sloped isotherms, indicating that defects act as additional barriers to the phase transformation. Our results resolve the formation and healing of structural defects during phase transformations at the single nanoparticle level and offer an additional perspective as to how and why nanoparticles differ from their bulk counterparts.« less

  5. Joint immobilization inhibits spontaneous hyaline cartilage regeneration induced by a novel double-network gel implantation.

    PubMed

    Arakaki, Kazunobu; Kitamura, Nobuto; Kurokawa, Takayuki; Onodera, Shin; Kanaya, Fuminori; Gong, Jian-Ping; Yasuda, Kazunori

    2011-02-01

    We have recently discovered that spontaneous hyaline cartilage regeneration can be induced in an osteochondral defect in the rabbit, when we implant a novel double-network (DN) gel plug at the bottom of the defect. To clarify whether joint immobilization inhibits the spontaneous hyaline cartilage regeneration, we conducted this study with 20 rabbits. At 4 or 12 weeks after surgery, the defect in the mobile knees was filled with a sufficient volume of the hyaline cartilage tissue rich in proteoglycan and type-2 collagen, while no cartilage tissues were observed in the defect in the immobilized knees. Type-2 collagen, Aggrecan, and SOX9 mRNAs were expressed only in the mobile knees at each period. This study demonstrated that joint immobilization significantly inhibits the spontaneous hyaline cartilage regeneration induced by the DN gel implantation. This fact suggested that the mechanical environment is one of the significant factors to induce this phenomenon.

  6. Naval Law Review, Volume 50, 2004

    DTIC Science & Technology

    2004-01-01

    Daubert v. Merrell Dow Pharmaceuticals136 the plaintiffs alleged that ingesting the drug Bendectin during pregnancy caused their children’s birth defects...34140 The Court also emphasized that other Courts of Appeals considering the risks of Bendectin had refused to admit reanalysis of epidemiological

  7. Mapping DICOM to OpenDocument format

    NASA Astrophysics Data System (ADS)

    Yu, Cong; Yao, Zhihong

    2009-02-01

    In order to enhance the readability, extensibility and sharing of DICOM files, we have introduced XML into DICOM file system (SPIE Volume 5748)[1] and the multilayer tree structure into DICOM (SPIE Volume 6145)[2]. In this paper, we proposed mapping DICOM to ODF(OpenDocument Format), for it is also based on XML. As a result, the new format realizes the separation of content(including text content and image) and display style. Meanwhile, since OpenDocument files take the format of a ZIP compressed archive, the new kind of DICOM files can benefit from ZIP's lossless compression to reduce file size. Moreover, this open format can also guarantee long-term access to data without legal or technical barriers, making medical images accessible to various fields.

  8. Brightness discrimination test is not useful in screening for open angle glaucoma.

    PubMed

    Peter, E; Thomas, R; Muliyil, J

    1996-06-01

    Brightness discrimination test (BDT) is routinely employed to assess asymmetrical optic nerve dysfunction and has been suggested as a screening test for primary open angle glaucoma (POAG). We tested the reliability and validity of BDT in the diagnosis of POAG. The study groups included 34 patients with established primary open angle glaucoma, 20 glaucoma suspects, and 33 age-sex matched controls. Cataract was not an exclusion criterion in these groups. The normal brightness score was determined to be 88% (mean score, 94%-2 SD) in a pilot study. Brightness discrimination test was performed in all subjects by two observers independently. BDT showed an excellent interobserver agreement (weighted Kappa 0.84). The presence of a cataract alone increased the risk of brightness impairment twofold, glaucoma alone increased the risk eightfold, and the presence of both conditions by 17 times compared to those with neither condition. BDT was not a useful test in the diagnosis of POAG (sensitivity 67% and specificity 93%); the ability to detect a significant field defect was also poor (sensitivity 53% and specificity 76%). There was poor association between decreased brightness scores and asymmetrical field defects as determined by the Humphrey's field analyzer (HFA).

  9. Hyperostosis in an orbital defect with craniofacial implants and open-field magnets: a clinical report.

    PubMed

    Sullivan, Maureen; Casey, David M; Alberico, Ronald; Litwin, Alan; Schaaf, Norman G

    2007-04-01

    An orbital facial prosthesis wearer was found to have significant hyperostosis in an exenterated orbit exposed to long-term, open field, rare earth magnets attached to craniofacial implants. Localized exophytic osseous formation was found in multiple areas around the exenterated orbit. The overall thickness of the walls of the exenterated orbit was approximately double that of the unaffected side. Magnetic field effect on bone formation and recommended treatment are discussed.

  10. Management of comminuted but continuous mandible defects after gunshot injuries.

    PubMed

    Rana, Majeed; Warraich, Riaz; Rashad, Ashkan; von See, Constantin; Channar, Kashif A; Rana, Madiha; Stoetzer, Marcus; Gellrich, Nils-Claudius

    2014-01-01

    Firearm injuries continue as a major public health problem, contributing significant morbidity, mortality, and expense to our society. There are four main steps in the management of patients with gunshot wounds to the face: securing an airway, controlling haemorrhage, identifying other injuries and definitive repair of the traumatic facial deformities. The objective of this study was to determine late outcome of two treatment options by open reduction and internal fixation versus closed reduction and maxillomandibular fixation (MMF) in the treatment of gunshot injuries of the mandible. Sixty patients of gunshot injury were randomly allocated in two groups. In group A, 30 patients were treated by open reduction and internal fixation and in group B, 30 patients were treated by closed reduction and maxillomandibular fixation. Patients were discharged as the treatment completed and recalled for follow up. Up to 3 months after injury, fortnightly complications like infection, malocclusion, malunion of fractured fragments, facial asymmetry, sequestration of bone and exposed plates were evaluated and the differences between two groups were assessed. The follow-up period ranged from 3 months to 10 months. Patients treated by open reduction tended to have less complications as compared to closed reduction. Based on this study open reduction and internal fixation is the best available method for the treatment of gunshot mandible fractures without continuity defect. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Architectural optimization of an epoxy-based hybrid sol-gel coating for the corrosion protection of a cast Elektron21 magnesium alloy

    NASA Astrophysics Data System (ADS)

    Murillo-Gutiérrez, N. V.; Ansart, F.; Bonino, J.-P.; Kunst, S. R.; Malfatti, C. F.

    2014-08-01

    An epoxy-based hybrid sol-gel coating was prepared in various architectural configurations has been studied for the corrosion protection of a cast Elektron21 magnesium alloy. The creation of a single layer of this coating presents defects consisting of macro-pores and protuberances, which opens access for corrosive species to reach the metallic substrate. These defects are suspected to result from the high reactivity of the substrate, as well as to the irregular topography of the substrate disrupted by the microstructure of the own magnesium alloy. Hence, a sol-gel coating in bilayer architecture is proposed, where the first layer would “inert” the surface of the magnesium substrate, and the second layer would cover the defects of the first layer and also thickening the coating. The morphological characteristics of the sol-gel coatings were analyzed by scanning electron microscopy (SEM), and their corrosion behavior was evaluated by OCP (open circuit potential) monitoring and electrochemical impedance spectroscopy (EIS) in chloride media. It is shown that both the architectural arrangement and the individual thickness of the first and second layers have an important influence on the anticorrosion performances of the protective system, just as much as its global thickness.

  12. Hydroxyapatite granules used in the obliteration of mastoid cavities in rats.

    PubMed

    Hamerschmidt, Rogério; Santos, Rafael Francisco dos; Araújo, João Cândido; Stahlke, Henrique Jorge; Agulham, Miguel Angelo; Moreira, Ana Tereza Ramos; Mocellin, Marcos

    2011-06-01

    Prospective experimental study in which we created a bony defect in the mastoids of rats and filled it up with hydroxyapatite to evaluate bone regeneration, to solve the problems of open cavities after mastoidectomies that frequently present with otorrhea, infection, granulation tissue and hearing loss. The aim was to evaluate bone regeneration in defects created in the mastoids of rats, using hydroxyapatite, to see how much of the cavity we could reduce. Twelve rats Wistar-Furth were used. A 0.5 x 0.5 cm bone defect was created in both temporal bones of the rats, and filled with 15 micrograms of hydroxyapatite. The left side was used as control. The animals were slaughtered 40 days afterwards and histology analyses were carried out. In the hydroxyapatite group, the new bone growth involved an area of 68.53% of the total; and in the control group it was only of 15.97%. It was observed a very good hydroxyapatite integration to the temporal bone in this experimental model. The microscopic results were superior with the use of hydroxyapatite when compared to the control group. It is a safe method and easy to apply to solve the problems of open cavities with chronic discharge and difficult to clean.

  13. Segmental liver incarceration through a recurrent incisional lumbar hernia.

    PubMed

    Salemis, Nikolaos S; Nisotakis, Konstantinos; Gourgiotis, Stavros; Tsohataridis, Efstathios

    2007-08-01

    Lumbar hernia is a rare congenital or acquired defect of the posterior abdominal wall. The acquired type is more common and occurs mainly as an incisional defect after flank surgery. Incarceration or strangulation of hernia contents is uncommon. Segmental liver incarceration through a recurrent incisional lumbar defect was diagnosed in a 58 years old woman by magnetic resonance imaging. The patient underwent an open repair of the complicated hernia. An expanded polytetraflouoroethylene (e-PTFE) mesh was fashioned as a sublay prosthesis. She had an uncomplicated postoperative course. Follow-up examinations revealed no evidence of recurrence. Although lumbar hernia rarely results in incarceration or strangulation, early repair is necessary because of the risks of complications and the increasing difficulty in repairment as it enlarges. Surgical repair is often difficult and challenging.

  14. Quantum Properties of Dichroic Silicon Vacancies in Silicon Carbide

    NASA Astrophysics Data System (ADS)

    Nagy, Roland; Widmann, Matthias; Niethammer, Matthias; Dasari, Durga B. R.; Gerhardt, Ilja; Soykal, Öney O.; Radulaski, Marina; Ohshima, Takeshi; Vučković, Jelena; Son, Nguyen Tien; Ivanov, Ivan G.; Economou, Sophia E.; Bonato, Cristian; Lee, Sang-Yun; Wrachtrup, Jörg

    2018-03-01

    Although various defect centers have displayed promise as either quantum sensors, single photon emitters, or light-matter interfaces, the search for an ideal defect with multifunctional ability remains open. In this spirit, we study the dichroic silicon vacancies in silicon carbide that feature two well-distinguishable zero-phonon lines and analyze the quantum properties in their optical emission and spin control. We demonstrate that this center combines 40% optical emission into the zero-phonon lines showing the contrasting difference in optical properties with varying temperature and polarization, and a 100% increase in the fluorescence intensity upon the spin resonance, and long spin coherence time of their spin-3 /2 ground states up to 0.6 ms. These results single out this defect center as a promising system for spin-based quantum technologies.

  15. Small bowel obstruction caused by congenital transmesenteric defect.

    PubMed

    Nouira, F; Dhaou, Ben M; Charieg, A; Ghorbel, S; Jlidi, S; Chaouachi, B

    2011-01-01

    Transmesenteric hernias are extremely rare. A strangulated hernia through a mesenteric opening is a rare operative finding. Preoperative diagnosis still is difficult in spite of the imaging techniques currently available. The authors describe two cases of paediatric patients presenting with bowel obstruction resulting from a congenital mesenteric hernia. The first patient had a 3-cm wide congenital defect in the ileal mesentery through which the sigmoid colon had herniated. The second patient is a newborn infant who presented with symptoms and radiographic evidence of neonatal occlusion. At surgical exploration, a long segment of the small bowel had herniated in a defect in the ileal mesentery. A brief review of epidemiology and anatomy of transmesenteric hernias is included, along with a discussion of the difficulties in diagnosis and treatment of this condition.

  16. First principles investigation of nitrogenated holey graphene

    NASA Astrophysics Data System (ADS)

    Xu, Cui-Yan; Dong, Hai-Kuan; Shi, Li-Bin

    2018-04-01

    The zero band gap problem limits the application of graphene in the field of electronic devices. Opening the band gap of graphene has become a research issue. Nitrogenated holey graphene (NHG) has attracted much attention because of its semiconducting properties. However, the stacking orders and defect properties have not been investigated. In this letter, the structural and stacking properties of NHG are first investigated. We obtain the most stable stacking structure. Then, the band structures for bulk and multilayer NHG are studied. Impact of the strain on the band gaps and bond characteristics is discussed. In addition, we investigate formation mechanism of native defects of carbon vacancy (VC), carbon interstitial (Ci), nitrogen vacancy (VN), and nitrogen interstitial (Ni) in bulk NHG. Formation energies and transition levels of these native defects are assessed.

  17. Molecular dynamics study of vacancy-like defects in a model glass : static behaviour

    NASA Astrophysics Data System (ADS)

    Delaye, J. M.; Limoge, Y.

    1993-10-01

    The possibility of defining vacancy-like defects in a Lennard-Jones glass is searched for in a systematic manner. Considering different relaxation levels of the same system, as well as different external pressures, we use a Molecular Dynamics simulation method, to study at constant volume or external pressure, the relaxation of a “piece” of glass, after the sudden removal of an atom. Three typical kinds of behaviour can be observed: the persistence of the empty volume left by the missing atom, its migration by clearly identifiable atomic jumps and the dissipation “on the spot”. A careful analysis of the probabilities of these three kinds of behaviour shows that a meaningful definition of vacancy-like defects can be given in a Lennard-Jones glass. Dans cet article, nous nous penchons de façon systématique sur la possibilité de définir des défauts de type lacunaire dans un verre de Lennard-Jones, à différents niveaux de relaxation et de pression, par une méthode de simulation numérique en dynamique moléculaire à volume ou à pression constants. Le défaut est créé en supprimant un atome et en suivant la réponse du système. Nous observons trois comportements typiques : la persistance sur place du “trou” laissé par l'atome supprimé, sa migration par des sauts atomiques clairement identifiés et enfin sa dissipation sur place. Une analyse détaillée de ces trois comportements montre qu'il est possible dans un verre de Lennard-Jones de définir des défauts de type lacunaire.

  18. Outcomes of Orbital Floor Reconstruction After Extensive Maxillectomy Using the Computer-Assisted Fabricated Individual Titanium Mesh Technique.

    PubMed

    Zhang, Wen-Bo; Mao, Chi; Liu, Xiao-Jing; Guo, Chuan-Bin; Yu, Guang-Yan; Peng, Xin

    2015-10-01

    Orbital floor defects after extensive maxillectomy can cause severe esthetic and functional deformities. Orbital floor reconstruction using the computer-assisted fabricated individual titanium mesh technique is a promising method. This study evaluated the application and clinical outcomes of this technique. This retrospective study included 10 patients with orbital floor defects after maxillectomy performed from 2012 through 2014. A 3-dimensional individual stereo model based on mirror images of the unaffected orbit was obtained to fabricate an anatomically adapted titanium mesh using computer-assisted design and manufacturing. The titanium mesh was inserted into the defect using computer navigation. The postoperative globe projection and orbital volume were measured and the incidence of postoperative complications was evaluated. The average postoperative globe projection was 15.91 ± 1.80 mm on the affected side and 16.24 ± 2.24 mm on the unaffected side (P = .505), and the average postoperative orbital volume was 26.01 ± 1.28 and 25.57 ± 1.89 mL, respectively (P = .312). The mean mesh depth was 25.11 ± 2.13 mm. The mean follow-up period was 23.4 ± 7.7 months (12 to 34 months). Of the 10 patients, 9 did not develop diplopia or a decrease in visual acuity and ocular motility. Titanium mesh exposure was not observed in any patient. All patients were satisfied with their postoperative facial symmetry. Orbital floor reconstruction after extensive maxillectomy with an individual titanium mesh fabricated using computer-assisted techniques can preserve globe projection and orbital volume, resulting in successful clinical outcomes. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Variation in practice patterns in device closure of atrial septal defects and patent ductus arteriosus: An analysis of data from the IMproving Pediatric and Adult Congenital Treatment (IMPACT) registry.

    PubMed

    O'Byrne, Michael L; Kennedy, Kevin F; Rome, Jonathan J; Glatz, Andrew C

    2018-02-01

    Practice variation is a potentially important measure of healthcare quality. The IMPACT registry provides a representative national sample with which to study practice variation in trans-catheter interventions for congenital heart disease. We studied cases for closure of atrial septal defect (ASD) and patent ductus arteriosus (PDA) in IMPACT between January 1, 2011, and September 30, 2015, using hierarchical multivariate models studying (1) the distribution of indications for closure and (2) in patients whose indication for closure was left (LVVO) or right ventricular volume overload (RVVO), the factors influencing probability of closure of a small defect (either in size or in terms of the magnitude of shunt). Over the study period, 5233 PDA and 4459 ASD cases were performed at 77 hospitals. The indications for ASD closure were RVVO in 84% and stroke prevention in 13%. Indications for PDA closure were LVVO in 57%, endocarditis prevention in 36%, and pulmonary hypertension in 7%. There was statistically significant variability in indications between hospitals for PDA and ASD procedures (median rate ratio (MRR): 1.3 and 1.1; both P<.001). The proportion of cases for volume overload with a Qp:Qs <1.5:1 decreased with increasing PDA and ASD procedural volume (P=.04 and 0.05). For ASD, the proportion was higher at hospitals with a larger proportion of adult cases (P=.0007). There was significant variation in practice in the risk of closing PDA <2 mm for LVVO (MRR: 1.4, P<.001). There is measurable variation in transcatheter closure of PDA and ASD. Further research is necessary to study whether this affects outcomes or resource utilization. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Altering intracellular pH reveals the kinetic basis of intraburst gating in the CFTR Cl− channel

    PubMed Central

    Xu, Weiyi; Sheppard, David N.

    2017-01-01

    Key points The cystic fibrosis transmembrane conductance regulator (CFTR), which is defective in the genetic disease cystic fibrosis (CF), forms a gated pathway for chloride movement regulated by intracellular ATP.To understand better CFTR function, we investigated the regulation of channel openings by intracellular pH.We found that short‐lived channel closures during channel openings represent subtle changes in the structure of CFTR that are regulated by intracellular pH, in part, at ATP‐binding site 1 formed by the nucleotide‐binding domains.Our results provide a framework for future studies to understand better the regulation of channel openings, the dysfunction of CFTR in CF and the action of drugs that repair CFTR gating defects. Abstract Cystic fibrosis transmembrane conductance regulator (CFTR) is an ATP‐gated Cl− channel defective in the genetic disease cystic fibrosis (CF). The gating behaviour of CFTR is characterized by bursts of channel openings interrupted by brief, flickery closures, separated by long closures between bursts. Entry to and exit from an open burst is controlled by the interaction of ATP with two ATP‐binding sites, sites 1 and 2, in CFTR. To understand better the kinetic basis of CFTR intraburst gating, we investigated the single‐channel activity of human CFTR at different intracellular pH (pHi) values. When compared with the control (pHi 7.3), acidifying pHi to 6.3 or alkalinizing pHi to 8.3 and 8.8 caused small reductions in the open‐time constant (τo) of wild‐type CFTR. By contrast, the fast closed‐time constant (τcf), which describes the short‐lived closures that interrupt open bursts, was greatly increased at pHi 5.8 and 6.3. To analyse intraburst kinetics, we used linear three‐state gating schemes. All data were satisfactorily modelled by the C1 ↔ O ↔ C2 kinetic scheme. Changing the intracellular ATP concentration was without effect on τo, τcf and their responses to pHi changes. However, mutations that disrupt the interaction of ATP with ATP‐binding site 1, including K464A, D572N and the CF‐associated mutation G1349D all abolished the prolongation of τcf at pHi 6.3. Taken together, our data suggest that the regulation of CFTR intraburst gating is distinct from the ATP‐dependent mechanism that controls channel opening and closing. However, our data also suggest that ATP‐binding site 1 modulates intraburst gating. PMID:27779763

Top