NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Sutton, M. A.
1993-01-01
The stable tearing behavior of thin sheets 2024-T3 aluminum alloy was studied for middle crack tension specimens having initial cracks that were: flat cracks (low fatigue stress) and 45 degrees through-thickness slant cracks (high fatigue stress). The critical crack-tip-opening angle (CTOA) values during stable tearing were measured by two independent methods, optical microscopy and digital image correlation. Results from the two methods agreed well. The CTOA measurements and observations of the fracture surfaces showed that the initial stable tearing behavior of low and high fatigue stress tests is significantly different. The cracks in the low fatigue stress tests underwent a transition from flat-to-slant crack growth, during which the CTOA values were high and significant crack tunneling occurred. After crack growth equal to about the thickness, CTOA reached a constant value of 6 deg and after crack growth equal to about twice the thickness, crack tunneling stabilized. The initial high CTOA values, in the low fatigue crack tests, coincided with large three-dimensional crack front shape changes due to a variation in the through-thickness crack tip constraint. The cracks in the high fatigue stress tests reach the same constant CTOA value after crack growth equal to about the thickness, but produced only a slightly higher CTOA value during initial crack growth. For crack growth on the 45 degree slant, the crack front and local field variables are still highly three-dimensional. However, the constant CTOA values and stable crack front shape may allow the process to be approximated with two-dimensional models.
Three-dimensional CTOA and constraint effects during stable tearing in a thin-sheet material
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Newman, J. C., Jr.; Bigelow, C. A.
1995-01-01
A small strain theory, three-dimensional elastic-plastic finite element analysis was used to simulate fracture in thin sheet 2024-T3 aluminum alloy in the T-L orientation. Both straight and tunneled cracks were modeled. The tunneled crack front shapes as a function of applied stress were obtained from the fracture surface of tested specimens. The stable crack growth behavior was measured at the specimen surface as a function of applied stress. The fracture simulation modeled the crack tunneling and extension as a function of applied stress. The results indicated that the global constraint factor, alpha(sub g), initially dropped during stable crack growth. After peak applied stress was achieved, alpha(sub g) began to increase slightly. The effect of crack front shape on alpha(sub g) was small, but the crack front shape did greatly influence the local constraint and through-thickness crack-tip opening angle (CTOA) behavior. The surface values of CTOA for the tunneled crack front model agreed well with experimental measurements, showing the same initial decrease from high values during the initial 3mm of crack growth at the specimen's surface. At the same time, the interior CTOA values increased from low angles. After the initial stable tearing region, the CTOA was constant through the thickness. The three-dimensional analysis appears to confirm the potential of CTOA as a two-dimensional fracture criterion.
A Relationship Between Constraint and the Critical Crack Tip Opening Angle
NASA Technical Reports Server (NTRS)
Johnston, William M.; James, Mark A.
2009-01-01
Of the various approaches used to model and predict fracture, the Crack Tip Opening Angle (CTOA) fracture criterion has been successfully used for a wide range of two-dimensional thin-sheet and thin plate applications. As thicker structure is considered, modeling the full three-dimensional fracture process will become essential. This paper investigates relationships between the local CTOA evaluated along a three-dimensional crack front and the corresponding local constraint. Previously reported tunneling crack front shapes were measured during fracture by pausing each test and fatigue cycling the specimens to mark the crack surface. Finite element analyses were run to model the tunneling shape during fracture, with the analysis loading conditions duplicating those tests. The results show an inverse relationship between the critical fracture value and constraint which is valid both before maximum load and after maximum load.
Residual Strength Analyses of Monolithic Structures
NASA Technical Reports Server (NTRS)
Forth, Scott (Technical Monitor); Ambur, Damodar R. (Technical Monitor); Seshadri, B. R.; Tiwari, S. N.
2003-01-01
Finite-element fracture simulation methodology predicts the residual strength of damaged aircraft structures. The methodology uses the critical crack-tip-opening-angle (CTOA) fracture criterion to characterize the fracture behavior of the material. The CTOA fracture criterion assumes that stable crack growth occurs when the crack-tip angle reaches a constant critical value. The use of the CTOA criterion requires an elastic- plastic, finite-element analysis. The critical CTOA value is determined by simulating fracture behavior in laboratory specimens, such as a compact specimen, to obtain the angle that best fits the observed test behavior. The critical CTOA value appears to be independent of loading, crack length, and in-plane dimensions. However, it is a function of material thickness and local crack-front constraint. Modeling the local constraint requires either a three-dimensional analysis or a two-dimensional analysis with an approximation to account for the constraint effects. In recent times as the aircraft industry is leaning towards monolithic structures with the intention of reducing part count and manufacturing cost, there has been a consistent effort at NASA Langley to extend critical CTOA based numerical methodology in the analysis of integrally-stiffened panels.In this regard, a series of fracture tests were conducted on both flat and curved aluminum alloy integrally-stiffened panels. These flat panels were subjected to uniaxial tension and during the test, applied load-crack extension, out-of-plane displacements and local deformations around the crack tip region were measured. Compact and middle-crack tension specimens were tested to determine the critical angle (wc) using three-dimensional code (ZIP3D) and the plane-strain core height (hJ using two-dimensional code (STAGS). These values were then used in the STAGS analysis to predict the fracture behavior of the integrally-stiffened panels. The analyses modeled stable tearing, buckling, and crack branching at the integral stiffener using different values of critical CTOA for different material thicknesses and orientation. Comparisons were made between measured and predicted load-crack extension, out-of-plane displacements and local deformations around the crack tip region. Simultaneously, three-dimensional capabilities to model crack branching and to monitor stable crack growth of multiple cracks in a large thick integrally-stiffened flat panels were implemented in three-dimensional finite element code (ZIP3D) and tested by analyzing the integrally-stiffened panels tested at Alcoa. The residual strength of the panels predicted from STAGS and ZP3D code compared very well with experimental data. In recent times, STAGS software has been updated with new features and now one can have combinations of solid and shell elements in the residual strength analysis of integrally-stiffened panels.
Residual Strength Analysis Methodology: Laboratory Coupons to Structural Components
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Newman, J. C., Jr.; Starnes, J. H., Jr.; Rose, C. A.; Young, R. D.; Seshadri, B. R.
2000-01-01
The NASA Aircraft Structural Integrity (NASIP) and Airframe Airworthiness Assurance/Aging Aircraft (AAA/AA) Programs have developed a residual strength prediction methodology for aircraft fuselage structures. This methodology has been experimentally verified for structures ranging from laboratory coupons up to full-scale structural components. The methodology uses the critical crack tip opening angle (CTOA) fracture criterion to characterize the fracture behavior and a material and a geometric nonlinear finite element shell analysis code to perform the structural analyses. The present paper presents the results of a study to evaluate the fracture behavior of 2024-T3 aluminum alloys with thickness of 0.04 inches to 0.09 inches. The critical CTOA and the corresponding plane strain core height necessary to simulate through-the-thickness effects at the crack tip in an otherwise plane stress analysis, were determined from small laboratory specimens. Using these parameters, the CTOA fracture criterion was used to predict the behavior of middle crack tension specimens that were up to 40 inches wide, flat panels with riveted stiffeners and multiple-site damage cracks, 18-inch diameter pressurized cylinders, and full scale curved stiffened panels subjected to internal pressure and mechanical loads.
Analyses of Buckling and Stable Tearing in Thin-Sheet Materials
NASA Technical Reports Server (NTRS)
Seshadri, B. R.; Newman, J. C., Jr.
1998-01-01
This paper was to verify the STAGS (general shell, geometric and material nonlinear) code and the critical crack tip opening angle (CTOA) fracture criterion for predicting stable tearing in cracked panels that fail with severe out of plane buckling. Materials considered ranged from brittle to ductile behavior. Test data used in this study are reported elsewhere. The STAGS code was used to model stable tearing using a critical CTOA value that was determined from a cracked panel that was 'restrained' from buckling. ne analysis methodology was then used to predict the influence of buckling on stable tearing and failure loads. Parameters like crack length to specimen width ratio, crack configuration, thickness, and material tensile properties had a significant influence on the buckling behavior of cracked thin sheet materials. Experimental and predicted results showed a varied buckling response for different crack length to sheet thickness ratios because different buckling modes were activated. Effects of material tensile properties and fracture toughness on buckling response were presented. The STAGS code and the CTOA fracture criterion were able to predict the influence of buckling on stable tearing behavior and failure loads on a variety of materials and crack configurations.
Fracture analysis of stiffened panels under biaxial loading with widespread cracking
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.; Dawicke, D. S.
1995-01-01
An elastic-plastic finite-element analysis with a critical crack-tip-opening angle (CTOA) fracture criterion was used to model stable crack growth and fracture of 2024-T3 aluminum alloy (bare and clad) panels for several thicknesses. The panels had either single or multiple-site damage (MSD) cracks subjected to uniaxial or biaxial loading. Analyses were also conducted on cracked stiffened panels with single or MSD cracks. The critical CTOA value for each thickness was determined by matching the failure load on a middle-crack tension specimen. Comparisons were made between the critical angles determined from the finite-element analyses and those measured with photographic methods. Predicted load-against-crack extension and failure loads for panels under biaxial loading, panels with MSD cracks, and panels with various number of stiffeners were compared with test data, whenever possible. The predicted results agreed well with the test data even for large-scale plastic deformations. The analyses were also able to predict stable tearing behavior of a large lead crack in the presence of MSD cracks. The analyses were then used to study the influence of stiffeners on residual strength in the presence of widespread fatigue cracking. Small MSD cracks were found to greatly reduce the residual strength for large lead cracks even for stiffened panels.
Fracture analysis of stiffened panels under biaxial loading with widespread cracking
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.
1995-01-01
An elastic-plastic finite-element analysis with a critical crack-tip opening angle (CTOA) fracture criterion was used to model stable crack growth and fracture of 2024-T3 aluminum alloy (bare and clad) panels for several thicknesses. The panels had either single or multiple-site damage (MSD) cracks subjected to uniaxial or biaxial loading. Analyses were also conducted on cracked stiffened panels with single or MSD cracks. The critical CTOA value for each thickness was determined by matching the failure load on a middle-crack tension specimen. Comparisons were made between the critical angles determined from the finite-element analyses and those measured with photographic methods. Predicted load-against-crack extension and failure loads for panels under biaxial loading, panels with MSD cracks, and panels with various numbers of stiffeners were compared with test data whenever possible. The predicted results agreed well with the test data even for large-scale plastic deformations. The analyses were also able to predict stable tearing behavior of a large lead crack in the presence of MSD cracks. The analyses were then used to study the influence of stiffeners on residual strength in the presence of widespread fatigue cracking. Small MSD cracks were found to greatly reduce the residual strength for large lead cracks even for stiffened panels.
A fracture criterion for widespread cracking in thin-sheet aluminum alloys
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.; Dawicke, D. S.; Sutton, M. A.; Bigelow, C. A.
1993-01-01
An elastic-plastic finite-element analysis was used with a critical crack-tip-opening angle (CTOA) fracture criterion to model stable crack growth in thin-sheet 2024-T3 aluminum alloy panels with single and multiple-site damage (MSD) cracks. Comparisons were made between critical angles determined from the analyses and those measured with photographic methods. Calculated load against crack extension and load against crack-tip displacement on single crack specimens agreed well with test data even for large-scale plastic deformations. The analyses were also able to predict the stable tearing behavior of large lead cracks in the presence of stably tearing MSD cracks. Small MSD cracks significantly reduced the residual strength for large lead cracks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luo, P.F.; Wang, J.S.; Chao, Y.J.
The stereo vision is used to study the fracture behavior in the compact tension (CT) specimen made from 304L stainless steel. During crack tip blunting, initiation, and growth in the CT specimen, both in-plane and out-of-plane displacement fields near the crack tip are measured by the stereo vision. Based on the plane stress assumption and the deformation theory of plasticity, the J integral is evaluated along several rectangular paths surrounding the crack tip by using the measured in-plane displacement field. Prior to crack growth, the J integral is path independent. For crack extension up to {Delta}a {approx} 3 mm, themore » near field J integral values are 6% to 10% lower than far field J integral values. For the crack extension of {Delta}a {approx} 4 mm, the J integral lost path independence. The far field J integral values are in good agreement with results obtained from Merkle-Corten`s formula. Both J-{Delta}a and CTOA-{Delta}a are obtained by computing the J integral value and crack tip opening angle (CTOA) at each {Delta}a. Results indicate that CTOA reached a nearly constant value at a crack extension of {Delta}a = 3 mm with a leveled resistance curve thereafter. Also, the J integral value is determined by the maximum transverse diameter of the shadow spots, which are generated by using the out-of-plane displacement field. Results indicate that for crack extension up to 0.25 mm, the J integral values evaluated by using the out-of- plane displacement are close to those obtained by using in-plane displacements and Merkle-Corten`s formula.« less
Orientation effects on the measurement and analysis of critical CTOA in an aluminum alloy sheet
NASA Technical Reports Server (NTRS)
Sutton, M. A.; Dawicke, D. S.; Newman, J. C., Jr.
1994-01-01
Fracture tests were conducted on 76.2mm wide, 2.3mm thick middle crack tension (M(T)) specimens machined from 2024-T3 aluminum sheet. The specimens were tested on the T-L orientation and comparisons were made to similar tests conducted in the L-T orientation. Measurement of critical crack tip opening angle (CTOA), applied stress, and crack front shape were made as a function of crack extension. A two-dimensional, elastic-plastic finite element analysis was used to simulate the fracture behavior for both orientations. The results indicate that the T-L orientation had a 10 percent lower stress at fracture than similar tests conducted in the L-T orientation. Correspondingly, the critical CTOA in the T-L tests reached a constant value of 4.7 degrees after 2-3mm of crack extension and the L-T tests reached a value of 6 degrees. The fracture surfaces of the T-L specimens were observed to remain flat, while those of the L-T specimens transitioned to a 45 degree slant fracture after about 2-3mm of crack extension. The tunneling behavior of the two orientations also differed; the T-L specimens reached a deeply tunneled stabilized crack front shape while, the L-T specimens were observed to have only a small amount of tunneling once the crack began to grow on the 45 degree slant. The two-dimensional, elastic-plastic finite element analysis was able to simulate the fracture behavior for both the T-L and L-T orientations.
A Review of the CTOA/CTOD Fracture Criterion: Why it Works
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.; James, M. A.
2001-01-01
The CTOA/CTOD fracture criterion is one of the oldest fracture criteria applied to fracture of metallic materials with cracks. During the past two decades, the use of elastic-plastic finite-element analyses to simulate fracture of laboratory specimens and structural components using the CTOA criterion has expanded rapidly. But the early applications were restricted to two-dimensional analyses, assuming either plane-stress or plane-strain behavior, which lead to generally non-constant values of CTOA, especially in the early stages crack extension. Later, the non-constant CTOA values were traced to inappropriate state-of-stress (or constraint) assumptions in the crack-front region and severe crack tunneling in thin-sheet materials. More recently, the CTOA fracture criterion has been used with three-dimensional analyses to study constraint effects, crack tunneling, and the fracture process. The constant CTOA criterion (from crack initiation to failure) has been successfully applied to numerous structural applications, such as aircraft fuselages and pipelines. But why does the "constant CTOA" fracture criterion work so well? This paper reviews the results from several studies, discusses the issues of why CTOA works, and discusses its limitations.
Effect of Measured Welding Residual Stresses on Crack Growth
NASA Technical Reports Server (NTRS)
Hampton, Roy W.; Nelson, Drew; Doty, Laura W. (Technical Monitor)
1998-01-01
Welding residual stresses in thin plate A516-70 steel and 2219-T87 aluminum butt weldments were measured by the strain-gage hole drilling and X-ray diffraction methods. The residual stress data were used to construct 3D strain fields which were modeled as thermally induced strains. These 3D strain fields were then analyzed with the WARP31) FEM fracture analysis code in order to predict their effect on fatigue and on fracture. For analyses of fatigue crack advance and subsequent verification testing, fatigue crack growth increments were simulated by successive saw-cuts and incremental loading to generate, as a function of crack length, effects on crack growth of the interaction between residual stresses and load induced stresses. The specimen experimental response was characterized and compared to the WARM linear elastic and elastic-plastic fracture mechanics analysis predictions. To perform the fracture analysis, the plate material's crack tearing resistance was determined by tests of thin plate M(T) specimens. Fracture analyses of these specimen were performed using WARP31D to determine the critical Crack Tip Opening Angle [CTOA] of each material. These critical CTOA values were used to predict crack tearing and fracture in the weldments. To verify the fracture predictions, weldment M(T) specimen were tested in monotonic loading to fracture while characterizing the fracture process.
Advances in Fatigue and Fracture Mechanics Analyses for Aircraft Structures
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.
1999-01-01
This paper reviews some of the advances that have been made in stress analyses of cracked aircraft components, in the understanding of the fatigue and fatigue-crack growth process, and in the prediction of residual strength of complex aircraft structures with widespread fatigue damage. Finite-element analyses of cracked structures are now used to determine accurate stress-intensity factors for cracks at structural details. Observations of small-crack behavior at open and rivet-loaded holes and the development of small-crack theory has lead to the prediction of stress-life behavior for components with stress concentrations under aircraft spectrum loading. Fatigue-crack growth under simulated aircraft spectra can now be predicted with the crack-closure concept. Residual strength of cracked panels with severe out-of-plane deformations (buckling) in the presence of stiffeners and multiple-site damage can be predicted with advanced elastic-plastic finite-element analyses and the critical crack-tip-opening angle (CTOA) fracture criterion. These advances are helping to assure continued safety of aircraft structures.
Advances in Fatigue and Fracture Mechanics Analyses for Metallic Aircraft Structures
NASA Technical Reports Server (NTRS)
Newman, J. C., Jr.
2000-01-01
This paper reviews some of the advances that have been made in stress analyses of cracked aircraft components, in the understanding of the fatigue and fatigue-crack growth process, and in the prediction of residual strength of complex aircraft structures with widespread fatigue damage. Finite-element analyses of cracked metallic structures are now used to determine accurate stress-intensity factors for cracks at structural details. Observations of small-crack behavior at open and rivet-loaded holes and the development of small-crack theory has lead to the prediction of stress-life behavior for components with stress concentrations under aircraft spectrum loading. Fatigue-crack growth under simulated aircraft spectra can now be predicted with the crack-closure concept. Residual strength of cracked panels with severe out-of-plane deformations (buckling) in the presence of stiffeners and multiple-site damage can be predicted with advanced elastic-plastic finite-element analyses and the critical crack-tip-opening angle (CTOA) fracture criterion. These advances are helping to assure continued safety of aircraft structures.
NASA Technical Reports Server (NTRS)
Young, Richard D.; Rouse, Marshall; Ambur, Damodar R.; Starnes, James H., Jr.
1999-01-01
The results of residual strength pressure tests and nonlinear analyses of stringer- and frame-stiffened aluminum fuselage panels with longitudinal cracks are presented. Two types of damage are considered: a longitudinal crack located midway between stringers, and a longitudinal crack adjacent to a stringer and along a row of fasteners in a lap joint that has multiple-site damage (MSD). In both cases, the longitudinal crack is centered on a severed frame. The panels are subjected to internal pressure plus axial tension loads. The axial tension loads are equivalent to a bulkhead pressure load. Nonlinear elastic-plastic residual strength analyses of the fuselage panels are conducted using a finite element program and the crack-tip-opening-angle (CTOA) fracture criterion. Predicted crack growth and residual strength results from nonlinear analyses of the stiffened fuselage panels are compared with experimental measurements and observations. Both the test and analysis results indicate that the presence of MSD affects crack growth stability and reduces the residual strength of stiffened fuselage shells with long cracks.
Stable tearing behavior of a thin-sheet material with multiple cracks
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Newman, J. C., Jr.; Sutton, M. A.; Amstutz, B. E.
1994-01-01
Fracture tests were conducted on 2.3mm thick, 305mm wide sheets of 2024-T3 aluminum alloy with 1-5 collinear cracks. The cracks were introduced (crack history) into the specimens by three methods: (1) saw cutting; (2) fatigue precracking at a low stress range; and (3) fatigue precracking at a high stress range. For the single crack tests, the initial crack history influenced the stress required for the onset of stable crack growth and the first 10mm of crack growth. The effect on failure stress was about 4 percent or less. For the multiple crack tests, the initial crack history was shown to cause differences of more than 20 percent in the link-up stress and 13 percent in failure stress. An elastic-plastic finite element analysis employing the Crack Tip Opening Angle (CTOA) fracture criterion was used to predict the fracture behavior of the single and multiple crack tests. The numerical predictions were within 7 percent of the observed link-up and failure stress in all the tests.
NASA Technical Reports Server (NTRS)
Young, Richard D.; Rouse, Marshall; Ambur, Damodar R.; Starnes, James H., Jr.
1998-01-01
The results of residual strength pressure tests and nonlinear analyses of stringer- and frame-stiffened aluminum fuselage panels with longitudinal cracks are presented. Two types of damage are considered: a longitudinal crack located midway between stringers, and a longitudinal crack adjacent to a stringer and along a row of fasteners in a lap joint that has multiple-site damage (MSD). In both cases, the longitudinal crack is centered on a severed frame. The panels are subjected to internal pressure plus axial tension loads. The axial tension loads are equivalent to a bulkhead pressure load. Nonlinear elastic-plastic residual strength analyses of the fuselage panels are conducted using a finite element program and the crack-tip-opening-angle (CTOA) fracture criterion. Predicted crack growth and residual strength results from nonlinear analyses of the stiffened fuselage panels are compared with experimental measurements and observations. Both the test and analysis results indicate that the presence of MSD affects crack growth stability and reduces the residual strength of stiffened fuselage shells with long cracks.
Residual Strength Prediction of Fuselage Structures with Multiple Site Damage
NASA Technical Reports Server (NTRS)
Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.
1999-01-01
This paper summarizes recent results on simulating full-scale pressure tests of wide body, lap-jointed fuselage panels with multiple site damage (MSD). The crack tip opening angle (CTOA) fracture criterion and the FRANC3D/STAGS software program were used to analyze stable crack growth under conditions of general yielding. The link-up of multiple cracks and residual strength of damaged structures were predicted. Elastic-plastic finite element analysis based on the von Mises yield criterion and incremental flow theory with small strain assumption was used. A global-local modeling procedure was employed in the numerical analyses. Stress distributions from the numerical simulations are compared with strain gage measurements. Analysis results show that accurate representation of the load transfer through the rivets is crucial for the model to predict the stress distribution accurately. Predicted crack growth and residual strength are compared with test data. Observed and predicted results both indicate that the occurrence of small MSD cracks substantially reduces the residual strength. Modeling fatigue closure is essential to capture the fracture behavior during the early stable crack growth. Breakage of a tear strap can have a major influence on residual strength prediction.
Residual Strength Analyses of Riveted Lap-Splice Joints
NASA Technical Reports Server (NTRS)
Seshadri, B. R.; Newman, J. C., Jr.
2000-01-01
The objective of this paper was to analyze the crack-linkup behavior in riveted-stiffened lap-splice joint panels with small multiple-site damage (MSD) cracks at several adjacent rivet holes. Analyses are based on the STAGS (STructural Analysis of General Shells) code with the critical crack-tip-opening angle (CTOA) fracture criterion. To account for high constraint around a crack front, the "plane strain core" option in STAGS was used. The importance of modeling rivet flexibility with fastener elements that accurately model load transfer across the joint is discussed. Fastener holes are not modeled but rivet connectivity is accounted for by attaching rivets to the sheet on one side of the cracks that simulated both the rivet diameter and MSD cracks. Residual strength analyses made on 2024-T3 alloy (1.6-mm thick) riveted-lap-splice joints with a lead crack and various size MSD cracks were compared with test data from Boeing Airplane Company. Analyses were conducted for both restrained and unrestrained buckling conditions. Comparison of results from these analyses and results from lap-splice-joint test panels, which were partially restrained against buckling indicate that the test results were bounded by the failure loads predicted by the analyses with restrained and unrestrained conditions.
Crack Growth Simulation and Residual Strength Prediction in Airplane Fuselages
NASA Technical Reports Server (NTRS)
Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.
1999-01-01
The objectives were to create a capability to simulate curvilinear crack growth and ductile tearing in aircraft fuselages subjected to widespread fatigue damage and to validate with tests. Analysis methodology and software program (FRANC3D/STAGS) developed herein allows engineers to maintain aging aircraft economically, while insuring continuous airworthiness, and to design more damage-tolerant aircraft for the next generation. Simulations of crack growth in fuselages were described. The crack tip opening angle (CTOA) fracture criterion, obtained from laboratory tests, was used to predict fracture behavior of fuselage panel tests. Geometrically nonlinear, elastic-plastic, thin shell finite element crack growth analyses were conducted. Comparisons of stress distributions, multiple stable crack growth history, and residual strength between measured and predicted results were made to assess the validity of the methodology. Incorporation of residual plastic deformations and tear strap failure was essential for accurate residual strength predictions. Issue related to predicting crack trajectory in fuselages were also discussed. A directional criterion, including T-stress and fracture toughness orthotropy, was developed. Curvilinear crack growth was simulated in coupon and fuselage panel tests. Both T-stress and fracture toughness orthotropy were essential to predict the observed crack paths. Flapping of fuselages were predicted. Measured and predicted results agreed reasonable well.
3-D modeling of ductile tearing using finite elements: Computational aspects and techniques
NASA Astrophysics Data System (ADS)
Gullerud, Arne Stewart
This research focuses on the development and application of computational tools to perform large-scale, 3-D modeling of ductile tearing in engineering components under quasi-static to mild loading rates. Two standard models for ductile tearing---the computational cell methodology and crack growth controlled by the crack tip opening angle (CTOA)---are described and their 3-D implementations are explored. For the computational cell methodology, quantification of the effects of several numerical issues---computational load step size, procedures for force release after cell deletion, and the porosity for cell deletion---enables construction of computational algorithms to remove the dependence of predicted crack growth on these issues. This work also describes two extensions of the CTOA approach into 3-D: a general 3-D method and a constant front technique. Analyses compare the characteristics of the extensions, and a validation study explores the ability of the constant front extension to predict crack growth in thin aluminum test specimens over a range of specimen geometries, absolutes sizes, and levels of out-of-plane constraint. To provide a computational framework suitable for the solution of these problems, this work also describes the parallel implementation of a nonlinear, implicit finite element code. The implementation employs an explicit message-passing approach using the MPI standard to maintain portability, a domain decomposition of element data to provide parallel execution, and a master-worker organization of the computational processes to enhance future extensibility. A linear preconditioned conjugate gradient (LPCG) solver serves as the core of the solution process. The parallel LPCG solver utilizes an element-by-element (EBE) structure of the computations to permit a dual-level decomposition of the element data: domain decomposition of the mesh provides efficient coarse-grain parallel execution, while decomposition of the domains into blocks of similar elements (same type, constitutive model, etc.) provides fine-grain parallel computation on each processor. A major focus of the LPCG solver is a new implementation of the Hughes-Winget element-by-element (HW) preconditioner. The implementation employs a weighted dependency graph combined with a new coloring algorithm to provide load-balanced scheduling for the preconditioner and overlapped communication/computation. This approach enables efficient parallel application of the HW preconditioner for arbitrary unstructured meshes.
Residual Strength Predictions with Crack Buckling
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Gullerud, A. S.; Dodds, R. H., Jr.; Hampton, R. W.
1999-01-01
Fracture tests were conducted on middle crack tension, M(T), and compact tension, C(T), specimens of varying widths, constructed from 0.063 inch thick sheets of 2024-T3 aluminum alloy. Guide plates were used to restrict out-of-plane displacements in about half of the tests. Analyses using the three-dimensional, elastic-plastic finite element code WARP3D simulated the tests with and without guide plates using a critical CTOA fracture criterion. The experimental results indicate that crack buckling reduced the failure loads by up to 40%. Using a critical CTOA value of 5.5 deg., the WARP3D analyses predicted the failure loads for the tests with guide plates within +/- 10% of the experimentally measured values. For the M(T) tests without guide plates, the WARP3D analyses predicted the failure loads for the 12 and 24 inch tests within 10%, while over predicting the failure loads for the 40 inch wide tests by about 20%.
Stable Tearing and Buckling Responses of Unstiffened Aluminum Shells with Long Cracks
NASA Technical Reports Server (NTRS)
Starnes, James H., Jr.; Rose, Cheryl A.
1999-01-01
The results of an analytical and experimental study of the nonlinear response of thin, unstiffened, aluminum cylindrical shells with a long longitudinal crack are presented. The shells are analyzed with a nonlinear shell analysis code that accurately accounts for global and local structural response phenomena. Results are presented for internal pressure and for axial compression loads. The effect of initial crack length on the initiation of stable crack growth and unstable crack growth in typical shells subjected to internal pressure loads is predicted using geometrically nonlinear elastic-plastic finite element analyses and the crack-tip-opening angle (CTOA) fracture criterion. The results of these analyses and of the experiments indicate that the pressure required to initiate stable crack growth and unstable crack growth in a shell subjected to internal pressure loads decreases as the initial crack length increases. The effects of crack length on the prebuckling, buckling and postbuckling responses of typical shells subjected to axial compression loads are also described. For this loading condition, the crack length was not allowed to increase as the load was increased. The results of the analyses and of the experiments indicate that the initial buckling load and collapse load for a shell subjected to axial compression loads decrease as the initial crack length increases. Initial buckling causes general instability or collapse of a shell for shorter initial crack lengths. Initial buckling is a stable local response mode for longer initial crack lengths. This stable local buckling response is followed by a stable postbuckling response, which is followed by general or overall instability of the shell.
Stable Tearing and Buckling Responses of Unstiffened Aluminum Shells with Long Cracks
NASA Technical Reports Server (NTRS)
Starnes, James H., Jr.; Rose, Cheryl A.
1998-01-01
The results of an analytical and experimental study of the nonlinear response of thin, unstiffened, aluminum cylindrical shells with a long longitudinal crack are presented. The shells are analyzed with a nonlinear shell analysis code that accurately accounts for global and local structural response phenomena. Results are presented for internal pressure and for axial compression loads. The effect of initial crack length on the initiation of stable crack growth and unstable crack growth in typical shells subjected to internal pressure loads is predicted using geometrically nonlinear elastic-plastic finite element analyses and the crack-tip-opening angle (CTOA) fracture criterion. The results of these analyses and of the experiments indicate that the pressure required to initiate stable crack growth and unstable crack growth in a shell subjected to internal pressure loads decreases as the initial crack length increases. The effects of crack length on the prebuckling, buckling and postbuckling responses of typical shells subjected to axial compression loads are also described. For this loading condition, the crack length was not allowed to increase as the load was increased. The results of the analyses and of the experiments indicate that the initial buckling load and collapse load for a shell subjected to axial compression loads decrease as the initial crack length increases. Initial buckling causes general instability or collapse of a shell for shorter initial crack lengths. Initial buckling is a stable local response mode for longer initial crack lengths. This stable local buckling response is followed by a stable postbuckling response, which is followed by general or overall instability of the shell.
Kudryashova, Elena V; Artemova, Tatiana M; Vinogradov, Alexei A; Gladilin, Alexander K; Mozhaev, Vadim V; Levashov, Andrey V
2003-04-01
Formation of enzyme-oligoamine complexes was suggested as an approach to obtain biocatalysts with enhanced resistance towards inactivation in water-organic media. Complex formation results in broadening (by 20-40% v/v ethanol) of the range of cosolvent concentrations where the enzyme retains its catalytic activity (stabilization effect). At moderate cosolvent concentrations (20-40% v/v) complex formation activates the enzyme (by 3-6 times). The magnitude of activation and stabilization effects increases with the number of possible electrostatic contacts between the protein surface and the molecules of oligoamines (OA). Circular dichroism spectra in the far-UV region show that complex formation stabilizes protein conformation and prevents aggregation in water-organic solvent mixtures. Two populations of the complexes with different thermodynamic stabilities were found in alpha-chymotrypsin (CT)-OA systems depending on the CT/OA ratio. The average dissociation constants and stoichiometries of both low- and high-affinity populations of the complexes were estimated. It appears that it is the low-affinity sites on the CT surface that are responsible for the activation effect.
Open-angle glaucoma; Chronic glaucoma; Chronic open-angle glaucoma; Primary open-angle glaucoma; Closed-angle glaucoma; Narrow-angle glaucoma; Angle-closure glaucoma; Acute glaucoma; Secondary glaucoma; Congenital glaucoma; Vision ...
Evaluation of blotchy pigments in the anterior chamber angle as a sign of angle closure
Rao, Harsha L; Mungale, Sachin C; Kumbar, Tukaram; Parikh, Rajul S; Garudadri, Chandra S
2012-01-01
Background: Blotchy pigments in the anterior chamber (AC) angle are considered diagnostic of primary angle closure (PAC). But there are no reports either on the prevalence of blotchy pigments in AC angles or the validity of this sign. Aims: To determine the prevalence of blotchy pigments in AC angles and to evaluate their relationship with glaucomatous optic neuropathy (GON) in eyes with occludable angles. Setting and Design: Cross-sectional, comparative study. Materials and Methods: Gonioscopy was performed in 1001 eyes of 526 subjects (245 eyes of 148 consecutive, occludable angle subjects and 756 eyes of 378 non-consecutive, open angle subjects), above 35 years of age. Quadrant-wise location of blotchy pigments was documented. Statistical Analysis: Odds of blotchy pigments in occludable angles against that in open angles were evaluated. Relationship of GON with blotchy pigments in occludable angle eyes was evaluated using a multivariate model. Results: Prevalence of blotchy pigments in occludable angles was 28.6% (95% CI, 22.9-34.3) and in open angles was 4.7% (95% CI, 3.2-6.3). Blotchy pigments were more frequently seen in inferior (16%) and superior quadrants (15%) of occludable angles, and inferior quadrant of open angles (4%). Odds of superior quadrant blotchy pigments in occludable angles were 33 times that in open angles. GON was seen in 107 occludable angle eyes. Blotchy pigments were not significantly associated with GON (odds ratio = 0.5; P = 0.1). Conclusions: Blotchy pigments were seen in 28.6% of occludable angle eyes and 4.7% of open angles eyes. Presence of blotchy pigments in the superior quadrant is more common in occludable angles. Presence of GON in occludable angle eyes was not associated with blotchy pigments. PMID:23202393
... damage. The types of glaucoma include the following: Open-angle glaucoma Open-angle glaucoma is the most common form of ... angle formed by the cornea and iris remains open, but the trabecular meshwork is partially blocked. This ...
Open-angle glaucoma in patients with diabetic retinopathy at the Puerto Rico Medical Center.
Cruz-lñigo, Yousef; Izquierdo, Natalio J; García, Omar; Pérez, Raúl
2012-01-01
The association of open-angle glaucoma (OAG) with diabetes mellitus remains controversial. We report on the frequency of open-angle glaucoma in patients having diabetic retinopathy in a population of the Puerto Rico Medical Center. A cross-sectional study of 1,442 patients was done. Only the chart of patients 40 years-of-age and older, with a diagnosis of diabetic retinopathy and/or open-angle glaucoma were included. Descriptive analysis was done. Unadjusted and gender-adjusted logistic regression analyses were used to estimate risk of developing open-angle glaucoma in patients with diabetic retinopathy for each subsequent decade. 1,040 patients were diagnosed with diabetic retinopathy from July 1, 2004 to June 30, 2009. Also, 402 patients were diagnosed with open-angle glaucoma from July 1, 2007 to June 30, 2009. Of the 1,040 patients with diabetic retinopathy, 64 patients (6.15%) also had OAG. According to our gender-adjusted logistic regression analysis the estimated risk of developing open-angle glaucoma for patients 40 years-of-age with diabetic retinopathy increased for each subsequent decade until the seventh decade, odds ratio = 5.07 (95% confidence interval: 1.62-15.86). Thereafter, it decreased, odds ratio = 2.07 (95% confidence interval: 0.36-11.82). Our findings suggest that Puerto Rico patients between 40 to 79 years of age with diabetic retinopathy have an increased risk of developing open-angle glaucoma with each subsequent decade. Screening for open-angle glaucoma in patients with diabetic retinopathy is of utmost importance in the aging Puerto Rico population to prevent blindness.
Kaushik, Sushmita; Jain, Rajeev; Pandav, Surinder Singh; Gupta, Amod
2006-09-01
To compare the ultrasound biomicroscopic measurement of the anterior chamber angle in Asian Indian eyes, with the angle width estimated by gonioscopy. Patients with open and closed angles attending a glaucoma clinic were recruited for the study. Temporal quadrants of the angles of patients were categorized by gonioscopy as Grade 0 to Grade 4, using Shaffer's classification. These angles were quantified by ultrasound biomicroscopy (UBM) using the following biometric characteristics: Angle opening distance at 250 micro (AOD 250) and 500 micro (AOD 500) from the scleral spur and trabecular meshwork-ciliary process distance (TCPD). The angles were further segregated as "narrow angles" (Schaffer's Grade 2 or less) and "open angles" (Schaffer's Grade 3 and 4). The UBM measurements were computed in each case and analyzed in relation to the gonioscopic angle evaluation. One hundred and sixty three eyes of 163 patients were analyzed. One hundred and six eyes had "narrow angles" and 57 eyes had "open angles" on gonioscopy. There was a significant difference among the mean UBM measurements of each angle grade estimated by gonioscopy (P < 0.001). The Pearson correlation coefficient between all UBM parameters and gonioscopy grades was significant at the 0.01 level. The mean AOD 250, AOD 500 and TCPD in narrow angles were 58+/-49 micro, 102+/-84 micro and 653+/-124 respectively, while it was 176+/-47 micro, 291+/-62 micro and 883+/-94 micro in eyes with open angles (P < 0.001) respectively. The angle width estimated by gonioscopy correlated significantly with the angle dimensions measured by UBM. Gonioscopy, though a subjective test, is a reliable method for estimation of the angle width.
Rebolleda, Gema; Pérez-Sarriegui, Ane; Díez-Álvarez, Laura; De Juan, Victoria; Muñoz-Negrete, Francisco J
2018-06-01
To compare the optic nerve head morphology among primary open-angle glaucoma, non-arteritic anterior ischemic optic neuropathy eyes, their fellow healthy eyes and control eyes, using spectral-domain optical coherence tomography with enhanced depth imaging. Observational cross-sectional study including 88 eyes of 68 patients. In this study, 23 non-arteritic anterior ischemic optic neuropathy eyes, 17 fellow unaffected eyes, 25 primary open-angle glaucoma eyes, and 23 age-matched control eyes were included. Peripapillary retinal nerve fiber layer thickness and optic disk area were evaluated. Bruch's membrane opening diameter, optic cup depth, anterior lamina cribrosa depth, and prelaminar tissue thickness were assessed. Non-arteritic anterior ischemic optic neuropathy and primary open-angle glaucoma eyes had similar visual field mean deviation and peripapillary retinal nerve fiber layer thickness (P = 0.6 and P = 0.56, respectively). Bruch's membrane opening diameter was significantly larger in primary open-angle glaucoma eyes than in control eyes (P = 0.02). Lamina cribrosa and disk cup were deeper in eyes with primary open-angle glaucoma than both control and non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Prelaminar tissue thickness was significantly thinner in primary open-angle glaucoma eyes than in non-arteritic anterior ischemic optic neuropathy eyes (P < 0.001). Lamina cribrosa was shallower in both non-arteritic anterior ischemic optic neuropathy and unaffected fellow eyes compared to healthy eyes (P < 0.001 and P = 0.04, respectively). No differences were found in the optic disk area. A forward lamina cribrosa placement and not a smaller disk could be involved in the pathogenesis of non-arteritic anterior ischemic optic neuropathy. A significantly larger Bruch's membrane opening diameter was found in primary open-angle glaucoma eyes compared with control eyes. This issue has clinical implications because Bruch's membrane opening has been considered a stable reference for disk-related measures.
Crack Growth Simulation and Residual Strength Prediction in Airplane Fuselages
NASA Technical Reports Server (NTRS)
Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.
1999-01-01
This is the final report for the NASA funded project entitled "Crack Growth Prediction Methodology for Multi-Site Damage." The primary objective of the project was to create a capability to simulate curvilinear fatigue crack growth and ductile tearing in aircraft fuselages subjected to widespread fatigue damage. The second objective was to validate the capability by way of comparisons to experimental results. Both objectives have been achieved and the results are detailed herein. In the first part of the report, the crack tip opening angle (CTOA) fracture criterion, obtained and correlated from coupon tests to predict fracture behavior and residual strength of built-up aircraft fuselages, is discussed. Geometrically nonlinear, elastic-plastic, thin shell finite element analyses are used to simulate stable crack growth and to predict residual strength. Both measured and predicted results of laboratory flat panel tests and full-scale fuselage panel tests show substantial reduction of residual strength due to the occurrence of multi-site damage (MSD). Detailed comparisons of n stable crack growth history, and residual strength between the predicted and experimental results are used to assess the validity of the analysis methodology. In the second part of the report, issues related to crack trajectory prediction in thin shells; an evolving methodology uses the crack turning phenomenon to improve the structural integrity of aircraft structures are discussed, A directional criterion is developed based on the maximum tangential stress theory, but taking into account the effect of T-stress and fracture toughness orthotropy. Possible extensions of the current crack growth directional criterion to handle geometrically and materially nonlinear problems are discussed. The path independent contour integral method for T-stress evaluation is derived and its accuracy is assessed using a p- and hp-version adaptive finite element method. Curvilinear crack growth is simulated in coupon tests and in full-scale fuselage panel tests. Both T-stress and fracture toughness orthotropy are found to be essential to predict the observed crack paths. The analysis methodology and software program (FRANC3D/STAGS) developed herein allows engineers to maintain aging aircraft economically while insuring continuous airworthiness. Consequently, it will improve the technology to support the safe operation of the current aircraft fleet as well as the design of more damage-tolerant aircraft for the next generation fleet.
On the evolution of jet energy and opening angle in strongly coupled plasma
NASA Astrophysics Data System (ADS)
Chesler, Paul M.; Rajagopal, Krishna
2016-05-01
We calculate how the energy and the opening angle of jets in {N} = 4 SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet /dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet /dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say the opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that {N} = 4 SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the {N} = 4 SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. We close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.
On the evolution of jet energy and opening angle in strongly coupled plasma
Chesler, Paul M.; Rajagopal, Krishna
2016-05-17
We calculate how the energy and the opening angle of jets in N = 4SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet/dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet/dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say themore » opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that N = 4SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the N = 4SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. In conclusion, we close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.« less
Hsia, Yen C; Moghimi, Sasan; Coh, Paul; Chen, Rebecca; Masis, Marisse; Lin, Shan C
2017-07-01
To evaluate intraocular pressure (IOP) change after cataract surgery in eyes with open-angle glaucoma (OAG) and its relationship to angle and anterior segment parameters measured by anterior segment optical coherence tomography (AS-OCT). University of California, San Francisco, California, USA. Prospective case series. Eyes were placed into a narrow-angle group or open-angle group based on gonioscopy grading. Biometric parameters were measured using AS-OCT (Visante) preoperatively, and IOP 4 months after surgery was obtained. The IOP change and its relationship to AS-OCT parameters were evaluated. Eighty-one eyes of 69 patients were enrolled. The mean age of the patients was 76.8 years. The preoperative IOP was 15.02 mm Hg on 1.89 glaucoma medications. The average mean deviation of preoperative visual field was -4.58 dB. The mean IOP reduction was 2.1 mm Hg (12.8%) from a preoperative mean of 15.0 mm Hg. The IOP reduction was significantly greater in eyes with narrow angles than in eyes with open angles (20.4% versus 8.0%) (P = .002). In multivariate analysis, preoperative IOP (β = -0.53, P < .001, R 2 = 0.40), angle-opening distance at 500 mm (β = 5.83, P = .02, R 2 = 0.45), angle-opening distance at 750 mm (β = 5.82, P = .001, R 2 = 0.52), and lens vault (β = -0.002, P = .009, R 2 = 0.47) were associated with IOP reduction postoperatively. In eyes with OAG, IOP reduction after cataract surgery was greater in eyes with narrower angles. Preoperative IOP, angle-opening distance, and lens vault were predictors for IOP reduction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
A Generalized Maxwell Model for Creep Behavior of Artery Opening Angle
Zhang, W.; Guo, X.; Kassab, G. S.
2009-01-01
An artery ring springs open into a sector after a radial cut. The opening angle characterizes the residual strain in the unloaded state, which is fundamental to understanding stress and strain in the vessel wall. A recent study revealed that the opening angle decreases with time if the artery is cut from the loaded state, while it increases if the cut is made from the no-load state due to viscoelasticity. In both cases, the opening angle approaches the same value in 3 hours. This implies that the characteristic relaxation time is about 10,000 sec. Here, the creep function of a generalized Maxwell model (a spring in series with six Voigt bodies) is used to predict the temporal change of opening angle in multiple time scales. It is demonstrated that the theoretical model captures the salient features of the experimental results. The proposed creep function may be extended to study the viscoelastic response of blood vessels under various loading conditions. PMID:19045526
The distinction between juvenile and adult-onset primary open-angle glaucoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiggs, J.L.; Haines, J.L.; Damji, K.F.
1996-01-01
Because of the significant differences between the juvenile and adult forms of open-angle glaucoma, especially with regard to inheritance, prevalence, severity, and age of onset, we read with interest the recent publication by Morissette et al., describing a pedigree with a phenotype that overlaps the distinctive features of juvenile-onset open-angle glaucoma (JOAG) and adult-onset primary open-angle glaucoma (usually abbreviated as POAG or COAG). These authors conclude that a gene mapped to human chromosome 1q21-q31 (GLC1A) can be responsible for both juvenile and adult forms of open-angle glaucoma. The implications of such a result could be extremely important, in light ofmore » the high prevalence of the adult form of the disease. However, while the data presented in this report suggest that variable expressivity of the GLC1A gene may lead to a broader range of onset for this form of juvenile glaucoma, these data do not identify the GLC1A gene as an important cause of POAG. To prevent misleading interpretations of this and similar studies, we wish to clarify the distinction between the juvenile and adult forms of open-angle glaucoma. 8 refs.« less
Tsuji, Takashi; Matsumoto, Morio; Nakamura, Masaya; Ishii, Ken; Fujita, Nobuyuki; Chiba, Kazuhiro; Watanabe, Kota
2017-09-01
The aim of the present study was to investigate the factors associated with C5 palsy by focusing on radiological parameters using multivariable analysis. The authors retrospectively assessed 190 patients with cervical spondylotic myelopathy treated by open-door laminoplasty. Four radiographic parameters-the number of expanded lamina, C3-C7 angle, lamina open angle and space anterior to the spinal cord-were evaluated to clarify the factors associated with C5 palsy. Of the 190 patients, 11 developed C5 palsy, giving an overall incidence of 5.8%. Although the number of expanded lamina, lamina open angle and space anterior to the spinal cord were significantly larger in C5 palsy group than those in non-palsy group, a multiple logistic regression analysis revealed that only the space anterior to the spinal cord (odds ratio 2.60) was a significant independent factor associated with C5 palsy. A multiple linear regression analysis indicated that the lamina open angle was associated with the space anterior to the spinal cord and the analysis identified the following equation: space anterior to the spinal cord (mm) = 1.54 + 0.09 × lamina open angle (degree). A cut-off value of 53.5° for the lamina open angle predicted the development of C5 palsy with a sensitivity of 72.7% and a specificity of 83.2%. The larger postoperative space anterior to the spinal cord, which was associated with the lamina open angle, was positively correlated with the higher incidence of C5 palsy.
Zebardast, Nazlee; Kavitha, Srinivasan; Krishnamurthy, Palaniswamy; Friedman, David S; Nongpiur, Monisha E; Aung, Tin; Quigley, Harry A; Ramulu, Pradeep Y; Venkatesh, Rengaraj
2016-12-01
To compare anterior segment optical coherence tomography (ASOCT) angle morphology before and after laser peripheral iridotomy (LPI) in a cohort of South Indian subjects with primary angle-closure suspect (PACS) or primary angle-closure/primary angle-closure glaucoma (PAC/PACG) and to examine baseline parameters associated with angle widening. Prospective observational study. A total of 244 subjects aged ≥30 years with PACS or PAC/PACG in at least 1 eye. The ASOCT images and angle gonioscopic grades were analyzed for all subjects at baseline and 2 weeks after LPI. Multivariable linear and logistic regression models were used to determine predictors of angle widening (change in mean angle opening distance [AOD750]) and angle opening (all 4 quadrants with trabecular meshwork [TM] visible on gonioscopy after LPI). Change in ASOCT parameters with LPI and baseline predictors of angle widening. Laser peripheral iridotomy resulted in angle widening on ASOCT with significant increases in AOD750, angle recess area, and trabecular iris surface area (P < 0.05 for all). Gonioscopically, 44.7% of all subjects had open angles in all 4 quadrants after LPI, with a greater percentage of angles open in the PACS group compared with the PAC/PACG group (52.4% vs. 36.4%; P = 0.01). In multivariable regression analyses, greater postoperative angle widening as defined by change in AOD750 was associated with shorter baseline AOD750 and axial length, and greater baseline anterior chamber depth, iris curvature, and lens vault (P ≤ 0.002 for all). Gonioscopic angle opening after LPI was more common with wider baseline angle width (modified Shaffer grade) and lower cup-to-disc ratio (P < 0.001 for both). In a South Indian population with PACS or PAC/PACG, LPI results in significant anterior chamber angle widening seen on both ASOCT and gonioscopy, although some degree of persistent iridotrabecular contact was present in approximately half of PACS eyes and approximately two thirds of PAC/PACG eyes on gonioscopy. The greatest widening by ASOCT was observed in eyes with features most consistent with greater baseline pupillary block. Copyright © 2016 American Academy of Ophthalmology. All rights reserved.
Undetected angle closure in patients with a diagnosis of open-angle glaucoma.
Varma, Devesh K; Simpson, Sarah M; Rai, Amandeep S; Ahmed, Iqbal Ike K
2017-08-01
The aim of this study was to identify the proportion of patients referred to a tertiary glaucoma centre with a diagnosis of open-angle glaucoma (OAG) who were found to have angle closure glaucoma. Retrospective chart review. Consecutive new patients referred for glaucoma management to a tertiary centre between July 2010 and December 2011 were reviewed. Patients whose referrals for glaucoma assessment specified angle status as "open" were included. The data collected included glaucoma specialist's angle assessment, diagnosis, and glaucoma severity. The status of those with 180 degrees or more Shaffer angle grading of 0 was classified as "closed." From 1234 glaucoma referrals, 179 cases were specified to have a diagnosis of OAG or when angles were known to be open. Of these, 16 (8.9%) were found on examination by the glaucoma specialist to have angle closure. Pseudoexfoliation was present in 4 of 16 patients (25%) in the missed angle-closure glaucoma (ACG) group and 22 of 108 patients (13.5%) in the remaining OAG group. There was no difference found in demographic or ocular biometric parameters between those with confirmed OAG versus those with missed ACG. Almost 1 in 11 patients referred by ophthalmologists to a tertiary glaucoma centre with a diagnosis of OAG were in fact found to have angle closure. Given the different treatment approaches for ACG versus OAG, this study suggests a need to strengthen angle evaluations. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.
Arabi, Hossein; Kamali Asl, Ali Reza; Ay, Mohammad Reza; Zaidi, Habib
2015-07-01
The purpose of this work is to evaluate the impact of optimization of magnification on performance parameters of the variable resolution X-ray (VRX) CT scanner. A realistic model based on an actual VRX CT scanner was implemented in the GATE Monte Carlo simulation platform. To evaluate the influence of system magnification, spatial resolution, field-of-view (FOV) and scatter-to-primary ratio of the scanner were estimated for both fixed and optimum object magnification at each detector rotation angle. Comparison and inference between these performance parameters were performed angle by angle to determine appropriate object position at each opening half angle. Optimization of magnification resulted in a trade-off between spatial resolution and FOV of the scanner at opening half angles of 90°-12°, where the spatial resolution increased up to 50% and the scatter-to-primary ratio decreased from 4.8% to 3.8% at a detector angle of about 90° for the same FOV and X-ray energy spectrum. The disadvantage of magnification optimization at these angles is the significant reduction of the FOV (up to 50%). Moreover, magnification optimization was definitely beneficial for opening half angles below 12° improving the spatial resolution from 7.5 cy/mm to 20 cy/mm. Meanwhile, the FOV increased by more than 50% at these angles. It can be concluded that optimization of magnification is essential for opening half angles below 12°. For opening half angles between 90° and 12°, the VRX CT scanner magnification should be set according to the desired spatial resolution and FOV. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Wiggs, Janey L.; Auguste, Josette; Allingham, R. Rand; Flor, Jason D.; Pericak-Vance, Margaret A.; Rogers, Kathryn; LaRocque, Karen R.; Graham, Felicia L.; Broomer, Bob; Del Bono, Elizabeth; Haines, Jonathan L.; Hauser, Michael
2005-01-01
Objective: To determine whether mutations in the optineurin gene contribute to susceptibility to adult-onset primary open-angle glaucoma. Methods: The optineurin gene was screened in 86 probands with adult-onset primary open-angle glaucoma and in 80 age-matched control subjects. Exons 4 and 5, containing the recurrent mutations identified in patients with normal-tension glaucoma, were sequenced in all individuals studied, while the remaining exons were screened for DNA sequence variants with denaturing high-performance liquid chromatography. Results: The recurrent mutation, Met98Lys, previously found to be associated with an increased risk of disease was found in 8 (9%) of 86 probands. We also found the Met98Lys mutation in 10% of individuals from a control population of similar age, sex, and ethnicity. Consistent segregation of the mutation with the disease was not demonstrated in any of the 8 families. No other DNA changes altering the amino acid structure of the protein were found. Conclusion: The mutations in the optineurin gene associated with normal-tension glaucoma are not associated with adult-onset primary open-angle glaucoma in this patient population. Clinical Relevance: Genetic abnormalities that render the optic nerve susceptible to degeneration are excellent candidates for genetic factors that could contribute to adult-onset primary open-angle glaucoma. Mutations in optineurin have been associated with normal-tension glaucoma, but are not associated with disease in patients with adult-onset primary open-angle glaucoma. This result may indicate that normal-tension glaucoma is not necessarily part of the phenotypic spectrum of adult open-angle glaucoma. PMID:12912697
Anterior Segment Imaging Predicts Incident Gonioscopic Angle Closure.
Baskaran, Mani; Iyer, Jayant V; Narayanaswamy, Arun K; He, Yingke; Sakata, Lisandro M; Wu, Renyi; Liu, Dianna; Nongpiur, Monisha E; Friedman, David S; Aung, Tin
2015-12-01
To investigate the incidence of gonioscopic angle closure after 4 years in subjects with gonioscopically open angles but varying degrees of angle closure detected on anterior segment optical coherence tomography (AS OCT; Visante; Carl Zeiss Meditec, Dublin, CA) at baseline. Prospective, observational study. Three hundred forty-two subjects, mostly Chinese, 50 years of age or older, were recruited, of whom 65 were controls with open angles on gonioscopy and AS OCT at baseline, and 277 were cases with baseline open angles on gonioscopy but closed angles (1-4 quadrants) on AS OCT scans. All subjects underwent gonioscopy and AS OCT at baseline (horizontal and vertical single scans) and after 4 years. The examiner performing gonioscopy was masked to the baseline and AS OCT data. Angle closure in a quadrant was defined as nonvisibility of the posterior trabecular meshwork by gonioscopy and visible iridotrabecular contact beyond the scleral spur in AS OCT scans. Gonioscopic angle closure in 2 or 3 quadrants after 4 years. There were no statistically significant differences in age, ethnicity, or gender between cases and controls. None of the control subjects demonstrated gonioscopic angle closure after 4 years. Forty-eight of the 277 subjects (17.3%; 95% confidence interval [CI], 12.8-23; P < 0.0001) with at least 1 quadrant of angle closure on AS OCT at baseline demonstrated gonioscopic angle closure in 2 or more quadrants, whereas 28 subjects (10.1%; 95% CI, 6.7-14.6; P < 0.004) demonstrated gonioscopic angle closure in 3 or more quadrants after 4 years. Individuals with more quadrants of angle closure on baseline AS OCT scans had a greater likelihood of gonioscopic angle closure developing after 4 years (P < 0.0001, chi-square test for trend for both definitions of angle closure). Anterior segment OCT imaging at baseline predicts incident gonioscopic angle closure after 4 years among subjects who have gonioscopically open angles and iridotrabecular contact on AS OCT at baseline. Copyright © 2015 American Academy of Ophthalmology. All rights reserved.
Fan, Dapeng; Wang, Wei; Hildebrand, Kevin A; Fan, Cun-Yi
2016-09-09
With the exception of normal anatomic changes in the medial collateral ligament and radial head, other factors related to carrying angle changes have not been systematically studied. We reviewed patients who underwent open arthrolysis of the elbow, and evaluated if open arthrolysis could change carrying angle. We then identified factors associated with carrying angle changes. Fifty patients with a minimum of 24 months of follow-up after open arthrolysis were evaluated retrospectively. Preoperative and postoperative carrying angles were compared. The carrying angles of 36 elbows in 36 patients were unchanged after surgery (Group A), while the carrying angles of 14 elbows in 14 patients increased postoperatively (Group B). In Group A, mean postoperative extension and flexion were 7° (range 0-24°) and 125° (range 10-135°) respectively, while mean postoperative pronation and supination were 60° (range 50-80°) and 65° (range 30-85°), respectively. In Group B, mean postoperative extension and flexion were 25° (range 0-40°) and 128° (range 60-138°), while mean postoperative pronation and supination were 65° (range 45-85°) and 60° (range 45-75°), respectively. No significant difference in range of motion and Mayo Elbow Performance Score was observed between the two groups. During open arthrolysis, humeral trochlea debridement and techniques for improving forearm rotation could increase carrying angle. However, this had no impact on elbow functional recovery.
Obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma.
Balbay, Ege G; Balbay, Oner; Annakkaya, Ali N; Suner, Kezban O; Yuksel, Harun; Tunç, Murat; Arbak, Peri
2014-10-01
To investigate the prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma. Case series. School of Medicine, Düzce University, Turkey. Twenty-one consecutive primary open-angle glaucoma patients (12 females and 9 males) who attended the out-patient clinic of the Department of Ophthalmology between July 2007 and February 2008 were included in this study. All patients underwent polysomnographic examination. The prevalence of obstructive sleep apnoea syndrome was 33.3% in patients with primary open-angle glaucoma; the severity of the condition was mild in 14.3% and moderate in 19.0% of the subjects. The age (P=0.047) and neck circumference (P=0.024) in patients with obstructive sleep apnoea syndrome were significantly greater than those without the syndrome. Triceps skinfold thickness in glaucomatous obstructive sleep apnoea syndrome patients reached near significance versus those without the syndrome (P=0.078). Snoring was observed in all glaucoma cases with obstructive sleep apnoea syndrome. The intra-ocular pressure of patients with primary open-angle glaucoma with obstructive sleep apnoea syndrome was significantly lower than those without obstructive sleep apnoea syndrome (P=0.006 and P=0.035 for the right and left eyes, respectively). There was no significant difference in the cup/disc ratio and visual acuity, except visual field defect, between primary open-angle glaucoma patients with and without obstructive sleep apnoea syndrome. Although it does not provide evidence for a cause-effect relationship, high prevalence of obstructive sleep apnoea syndrome in patients with primary open-angle glaucoma in this study suggests the need to explore the long-term results of coincidence, relationship, and cross-interaction of these two common disorders.
Fingert, John H.; Robin, Alan L.; Scheetz, Todd E.; Kwon, Young H.; Liebmann, Jeffrey M.; Ritch, Robert; Alward, Wallace L.M.
2016-01-01
Purpose To investigate the role of TANK-binding kinase 1 (TBK1) gene copy-number variations (ie, gene duplications and triplications) in the pathophysiology of various open-angle glaucomas. Methods In previous studies, we discovered that copy-number variations in the TBK1 gene are associated with normal-tension glaucoma. Here, we investigated the prevalence of copy-number variations in cohorts of patients with other open-angle glaucomas—juvenile-onset open-angle glaucoma (n=30), pigmentary glaucoma (n=209), exfoliation glaucoma (n=225), and steroid-induced glaucoma (n=79)—using a quantitative polymerase chain reaction assay. Results No TBK1 gene copy-number variations were detected in patients with juvenile-onset open-angle glaucoma, pigmentary glaucoma, or steroid-induced glaucoma. A TBK1 gene duplication was detected in one (0.44%) of the 225 exfoliation glaucoma patients. Conclusions TBK1 gene copy-number variations (gene duplications and triplications) have been previously associated with normal-tension glaucoma. An exploration of other open-angle glaucomas detected a TBK1 copy-number variation in a patient with exfoliation glaucoma, which is the first example of a TBK1 mutation in a glaucoma patient with a diagnosis other than normal-tension glaucoma. A broader phenotypic range may be associated with TBK1 copy-number variations, although mutations in this gene are most often detected in patients with normal-tension glaucoma. PMID:27881886
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chesler, Paul M.; Rajagopal, Krishna
We calculate how the energy and the opening angle of jets in N = 4SYM theory evolve as they propagate through the strongly coupled plasma of that theory. We define the rate of energy loss dE jet/dx and the jet opening angle in a straightforward fashion directly in the gauge theory before calculating both holographically, in the dual gravitational description. In this way, we rederive the previously known result for dE jet/dx without the need to introduce a finite slab of plasma. We obtain a striking relationship between the initial opening angle of the jet, which is to say themore » opening angle that it would have had if it had found itself in vacuum instead of in plasma, and the thermalization distance of the jet. Via this relationship, we show that N = 4SYM jets with any initial energy that have the same initial opening angle and the same trajectory through the plasma experience the same fractional energy loss. We also provide an expansion that describes how the opening angle of the N = 4SYM jets increases slowly as they lose energy, over the fraction of their lifetime when their fractional energy loss is not yet large. In conclusion, we close by looking ahead toward potential qualitative lessons from our results for QCD jets produced in heavy collisions and propagating through quark-gluon plasma.« less
Fingert, John H; Robin, Alan L; Scheetz, Todd E; Kwon, Young H; Liebmann, Jeffrey M; Ritch, Robert; Alward, Wallace L M
2016-08-01
To investigate the role of TANK-binding kinase 1 ( TBK1 ) gene copy-number variations (ie, gene duplications and triplications) in the pathophysiology of various open-angle glaucomas. In previous studies, we discovered that copy-number variations in the TBK1 gene are associated with normal-tension glaucoma. Here, we investigated the prevalence of copy-number variations in cohorts of patients with other open-angle glaucomas-juvenile-onset open-angle glaucoma (n=30), pigmentary glaucoma (n=209), exfoliation glaucoma (n=225), and steroid-induced glaucoma (n=79)-using a quantitative polymerase chain reaction assay. No TBK1 gene copy-number variations were detected in patients with juvenile-onset open-angle glaucoma, pigmentary glaucoma, or steroid-induced glaucoma. A TBK1 gene duplication was detected in one (0.44%) of the 225 exfoliation glaucoma patients. TBK1 gene copy-number variations (gene duplications and triplications) have been previously associated with normal-tension glaucoma. An exploration of other open-angle glaucomas detected a TBK1 copy-number variation in a patient with exfoliation glaucoma, which is the first example of a TBK1 mutation in a glaucoma patient with a diagnosis other than normal-tension glaucoma. A broader phenotypic range may be associated with TBK1 copy-number variations, although mutations in this gene are most often detected in patients with normal-tension glaucoma.
Auditory processing deficits in individuals with primary open-angle glaucoma.
Rance, Gary; O'Hare, Fleur; O'Leary, Stephen; Starr, Arnold; Ly, Anna; Cheng, Belinda; Tomlin, Dani; Graydon, Kelley; Chisari, Donella; Trounce, Ian; Crowston, Jonathan
2012-01-01
The high energy demand of the auditory and visual pathways render these sensory systems prone to diseases that impair mitochondrial function. Primary open-angle glaucoma, a neurodegenerative disease of the optic nerve, has recently been associated with a spectrum of mitochondrial abnormalities. This study sought to investigate auditory processing in individuals with open-angle glaucoma. DESIGN/STUDY SAMPLE: Twenty-seven subjects with open-angle glaucoma underwent electrophysiologic (auditory brainstem response), auditory temporal processing (amplitude modulation detection), and speech perception (monosyllabic words in quiet and background noise) assessment in each ear. A cohort of age, gender and hearing level matched control subjects was also tested. While the majority of glaucoma subjects in this study demonstrated normal auditory function, there were a significant number (6/27 subjects, 22%) who showed abnormal auditory brainstem responses and impaired auditory perception in one or both ears. The finding that a significant proportion of subjects with open-angle glaucoma presented with auditory dysfunction provides evidence of systemic neuronal susceptibility. Affected individuals may suffer significant communication difficulties in everyday listening situations.
46 CFR 172.065 - Damage stability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... of sinkage, heel, and trim, must be below the lower edge of an opening through which progressive... sliding watertight door; or (vi) Side scuttle of the non-opening type. (2) Heel angle. The maximum angle of heel must not exceed 25 degrees, except that this angle may be increased to 30 degrees if no deck...
46 CFR 172.065 - Damage stability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... of sinkage, heel, and trim, must be below the lower edge of an opening through which progressive... sliding watertight door; or (vi) Side scuttle of the non-opening type. (2) Heel angle. The maximum angle of heel must not exceed 25 degrees, except that this angle may be increased to 30 degrees if no deck...
Biomarkers in primary open angle glaucoma.
Kokotas, Haris; Kroupis, Christos; Chiras, Dimitrios; Grigoriadou, Maria; Lamnissou, Klea; Petersen, Michael B; Kitsos, George
2012-12-01
Glaucoma, a leading cause of blindness worldwide, is currently defined as a disturbance of the structural or functional integrity of the optic nerve that causes characteristic atrophic changes in the optic nerve, which may lead to specific visual field defects over time. This disturbance usually can be arrested or diminished by adequate lowering of intraocular pressure (IOP). Glaucoma can be divided roughly into two main categories, ‘ open angle ’ and ‘ closed angle ’ glaucoma.Open angle, chronic glaucoma tends to progress at a slower rate and patients may not notice loss of vision until the disease has progressed significantly. Primary open angle glaucoma(POAG) is described distinctly as a multifactorial optic neuropathy that is chronic and progressive with a characteristic acquired loss of optic nerve fibers. Such loss develops in the presence of open anterior chamber angles, characteristic visual field abnormalities, and IOP that is too high for the healthy eye. It manifests by cupping and atrophy of the optic disc, in the absence of other known causes of glaucomatous disease. Several biological markers have been implicated with the disease. The purpose of this study was to summarize the current knowledge regarding the non-genetic molecular markers which have been predicted to have an association with POAG but have not yet been validated.
NASA Astrophysics Data System (ADS)
Schneider, Ling; Laustsen, Milan; Mandsberg, Nikolaj; Taboryski, Rafael
2016-02-01
We discuss the influence of surface structure, namely the height and opening angles of nano- and microcones on the surface wettability. We show experimental evidence that the opening angle of the cones is the critical parameter on sample superhydrophobicity, namely static contact angles and roll-off angles. The textured surfaces are fabricated on silicon wafers by using a simple one-step method of reactive ion etching at different processing time and gas flow rates. By using hydrophobic coating or hydrophilic surface treatment, we are able to switch the surface wettability from superhydrophilic to superhydrophobic without altering surface structures. In addition, we show examples of polymer replicas (polypropylene and poly(methyl methacrylate) with different wettability, fabricated by injection moulding using templates of the silicon cone-structures.
Effect of aperture geometry on heat transfer in tilted partially open cavities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elsayed, M.M.; Chakroun, W.
1999-11-01
Heat transfer in cavities is receiving increasing attention because of the various applications in engineering; e.g., passive solar heating, energy conservation in buildings, solar concentrating receivers, and electronic equipment. Here, convection from a square, tilted partially open cavity was investigated experimentally. The experiment was carried out to study the effect of the aperture geometry on the heat transfer between the cavity and the surrounding air. Four different geometrical arrangements for the opening were investigated: (1) high wall slit, (2) low wall slit, (3) centered wall slit, and (4) uniform wall slots. Each opening arrangement was studied at opening ratios (i.e.,more » ratio of opening height to cavity height) of 0.25, 0.5, and 0.75. The average heat transfer coefficient between the cavity and the surrounding air was estimated for each geometrical arrangement for tilt angles ranging from {minus}90 deg to +90 deg with increments of 15 deg and at a constant heat flux Grashof number of 5.5 x 10{sup 8}. The results showed that for tilt angles between 90 and 75 deg, the heat transfer coefficient has a small value that is independent of the geometrical arrangement of the opening. The value of the heat transfer coefficient increases sharply with decreasing tilt angle until an angle value of zero degrees is reached. The increase in the heat transfer coefficient continues in the negative range of tilt angle but not in the same rate as in the positive range of the tilt angle. The uniform slot arrangement gave in general higher heat transfer coefficient than the other three arrangements of the opening. Large differences in the heat transfer coefficient were observed between the high and the low wall slits where the high wall slit is found to transfer more heat to the surroundings than the low wall slit. Correlations were developed to predict the average Nusselt number of the cavity in terms of the opening ratio and the cavity tilt angle for cavities with high wall slit, low wall slit, centered wall slit, and the uniform wall slots.« less
Veselova, E V; Kamenskikh, T G; Raĭgorodkiĭ, Iu M; Kolbenev, I O; Myshkina, E S
2010-01-01
The traveling magnetic field was used to treat primary open-angle glaucoma. The field was applied to the projection of cervical sympathetic ganglia of the patients. Hemodynamic parameters of posterior short ciliary arteries and central retinal artery were analysed along with visual evoked potentials, visual field limits, and visual acuity. It was shown that magnetotherapy with the use of an AMO-ATOS apparatus produces better clinical results in patients with stage I and II primary open-angle glaucoma compared with medicamentous therapy (intake of trental tablets).
46 CFR 174.207 - Damaged stability criteria.
Code of Federal Regulations, 2011 CFR
2011-10-01
... sinkage, heel, and trim, must be below the lower edge of an opening through which progressive flooding may... of this subpart; or (v) Side scuttle of the non-opening type. (2) Angle of heel. The angle of heel...
High prevalence of narrow angles among Chinese-American glaucoma and glaucoma suspect patients.
Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C
2009-01-01
To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data were collected for sex, age, race (self-declared), refraction (spherical equivalent), intraocular pressure, gonioscopy, and vertical cup-to-disk ratio. Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade < or = 2 in 3 or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the 2 groups did not differ in terms of sex, refraction, intraocular pressure, or cup-to-disk ratio (all, P > or = 0.071). In a multivariate model including age, sex, and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of sex or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed.
Goyushov, Samir; Tözüm, Melek Didem; Tözüm, Tolga Fikret
2018-05-25
To determine the shape, position, vertical height, surrounding bone characteristics, and opening angle of mental foramen (MF) using dental cone beam computed tomography (CBCT). A retrospective study was performed on 663 patients. CBCT records analyzed for the shape, position, and surrounding bone measurements of the MF using Simplant 3D software (Hasselt, Belgium). Opening angle of MF was also assessed. Kruskal-Wallis and Mann-Whitney U tests were employed to test significant differences between parameters, genders and ages. All mental foramina were visualized. Regarding location, 49.2% of the MFs were located between first and second premolars, 7.7 distal and 39.7% coincident to the apex of the mandibular second premolar. The mean MF opening angle was 45.4° on the right side, and 45.9° on the left. There were no statistically differences between gender groups with regard to the opening angle degrees. This study may provide useful information about variations in the position, shape and size, angle of mental foramen, which may help the practitioners to perform safer mental nerve blocks and surgical procedures.
Nguyen, Donna; Minnal, Vandana R.
2016-01-01
Purpose. To evaluate interobserver, intervisit, and interinstrument agreements for gonioscopy and Fourier domain anterior segment optical coherence tomography (FD ASOCT) for classifying open and narrow angle eyes. Methods. Eighty-six eyes with open or narrow anterior chamber angles were included. The superior angle was classified open or narrow by 2 of 5 glaucoma specialists using gonioscopy and imaged by FD ASOCT in the dark. The superior angle of each FD ASOCT image was graded as open or narrow by 2 masked readers. The same procedures were repeated within 6 months. Kappas for interobserver and intervisit agreements for each instrument and interinstrument agreements were calculated. Results. The mean age was 50.9 (±18.4) years. Interobserver agreements were moderate to good for both gonioscopy (0.57 and 0.69) and FD ASOCT (0.58 and 0.75). Intervisit agreements were moderate to excellent for both gonioscopy (0.53 to 0.86) and FD ASOCT (0.57 and 0.85). Interinstrument agreements were fair to good (0.34 to 0.63), with FD ASOCT classifying more angles as narrow than gonioscopy. Conclusions. Both gonioscopy and FD ASOCT examiners were internally consistent with similar interobserver and intervisit agreements for angle classification. Agreement between instruments was fair to good, with FD ASOCT classifying more angles as narrow than gonioscopy. PMID:27990300
Glaucoma anterior chamber morphometry based on optical Scheimpflug images.
Alonso, Ruiz Simonato; Ambrósio Junior, Renato; Paranhos Junior, Augusto; Sakata, Lisandro Massanori; Ventura, Marcelo Palis
2010-01-01
To compare the performance of gonioscopy and noncontact morphometry with anterior chamber tomography (High Resolution Pentacam - HR) using optical Scheimpflug images in the evaluation of the anterior chamber angle (ACA). Transversal study. 112 eyes from 74 subjects evaluated at the Glaucoma Department, Fluminense Federal University, underwent gonioscopy and Pentacam HR. Using gonioscopy, the ACA was graded using the Shaffer Classification (SC) by a single experienced examiner masked to the Pentacam HR findings. Narrow angle was determined in eyes in which the posterior trabecular meshwork could not be seen in two or more quadrants on non-indentation gonioscopy (SC Grade 2 or less). Pentacam HR images of the nasal and temporal quadrants were evaluated by custom software to automatically obtain anterior chamber measurements, such as: anterior chamber angle (ACA), anterior chamber volume (ACV) and anterior chamber depth (ACD). Based on gonioscopy results, 74 (60.07%) eyes of patients classified as open-angle (SC 3 and 4) and 38 (33.93%) eyes of patients classified as narrow-angle (SC 1 and 2). Noncontact morphometry with Scheimpflug images revealed a mean ACA of 39.20 ± 5.31 degrees for open-angle and 21.18 ± 7.98 degrees for narrow-angle. The open-angle group showed significant greater ACV and ACD values when compared to narrow-angle group (ACV of 193 ± 36 mm³ vs. 90 ± 25 mm³, respectively, p<0.001; and ACD of 3,09 ± 0,42 mm vs. 1,55 ± 0,64 mm, respectively, p<0.0001.). In screening eyes with open-angle and narrow-angle with the Pentacam ACA of 20º (SC Grade 2) using the ROC curves, the analysis showed 52.6% of sensitivity and 100% of specificity. The Pentacam showed ability in detecting eyes at risk for angle closure analyzing ACV and ACD.
Peripapillary schisis in open-angle glaucoma.
Dhingra, N; Manoharan, R; Gill, S; Nagar, M
2017-03-01
PurposeTo report clinical features, topographic findings and outcome of 10 eyes with peripapillary schisis in open-angle glaucoma.Patients and methodsA retrospective review of patients with open-angle glaucoma who were noted to have peripapillary schisis on optical coherence tomography (OCT) were included. Serial peripapillary and macula infrared and OCT images, visual acuity, visual fields, and schisis appearance were reviewed.ResultsTen eyes of nine patients with open-angle glaucoma were detected to have the presence of peripapillary schisis. Nerve fibre layer schisis was detected in all eyes and one eye had an associated macular schisis. None of the eyes had an acquired pit of the optic nerve or pathological myopia. The mean intraocular pressures at detection was 18.3±4.3 mm Hg and the schisis resolved in four eyes after a mean follow-up of 21.2±8.8 months. Visual field worsening was noted in 4 of the 10 eyes and the resolution of schisis resulted in significant reduction in the retinal nerve fibre layer (RNFL) thickness.ConclusionsPeripapillary schisis detected during the normal course of open-angle glaucoma can resolve spontaneously and rarely involves the macula. Its resolution leads to reduction in RNFL thickness; therefore, caution is advised while interpreting serial scans.
Park, Seong Bae; Sung, Kyung Rim; Kang, Sung Yung; Jo, Jung Woo; Lee, Kyoung Sub; Kook, Michael S
2011-07-01
To evaluate anterior chamber (AC) angles using gonioscopy, Van Herick technique and anterior segment optical coherence tomography (AS-OCT). One hundred forty-eight consecutive subjects were enrolled. The agreement between any two of three diagnostic methods, gonioscopy, AS-OCT and Van Herick, was calculated in narrow-angle patients. The area under receiver-operating characteristic curves (AUC) for discriminating between narrow and open angles determined by gonioscopy was calculated in all participants for AS-OCT parameter angle opening distance (AOD), angle recess area, trabecular iris surface area and anterior chamber depth (ACD). As a subgroup analysis, capability of AS-OCT parameters for detecting angle closure defined by AS-OCT was assessed in narrow-angle patients. The agreement between the Van Herick method and gonioscopy in detecting angle closure was excellent in narrow angles (κ = 0.80, temporal; κ = 0.82, nasal). However, agreement between gonioscopy and AS-OCT and between the Van Herick method and AS-OCT was poor (κ = 0.11-0.16). Discrimination capability of AS-OCT parameters between open and narrow angles determined by gonioscopy was excellent for all AS-OCT parameters (AUC, temporal: AOD500 = 0.96, nasal: AOD500 = 0.99). The AUCs for detecting angle closure defined by AS-OCT image in narrow angle subjects was good for all AS-OCT parameters (AUC, 0.80-0.94) except for ACD (temporal: ACD = 0.70, nasal: ACD = 0.63). Assessment of narrow angles by gonioscopy and the Van Herick technique showed good agreement, but both measurements revealed poor agreement with AS-OCT. The angle closure detection capability of AS-OCT parameters was excellent; however, it was slightly lower in ACD.
High Prevalence of Narrow Angles among Chinese-American Glaucoma and Glaucoma Suspect Patients
Seider, Michael I; Pekmezci, Melike; Han, Ying; Sandhu, Simi; Kwok, Shiu Y; Lee, Roland Y; Lin, Shan C
2009-01-01
Purpose To evaluate the prevalence of gonioscopically narrow angles in a Chinese-American population with glaucoma or glaucoma suspicion. Patients and Methods Charts from all Chinese-American patients seen in a comprehensive ophthalmology clinic in the Chinatown district of San Francisco in 2002 were reviewed. One eye from each patient with glaucoma or glaucoma suspicion that met inclusion criteria was included (n=108). Data was collected for gender, age, race (self-declared), refraction (spherical equivalent), intraocular pressure (IOP), gonioscopy and vertical cup-to-disk ratio (CDR). Results Sixty percent (n=65) of Chinese-American eyes with glaucoma or glaucoma suspicion had gonioscopically narrow angles (Shaffer grade ≤2 in three or more quadrants). Those with narrow angles were significantly older (P=0.004) than their open angle counterparts, but the two groups did not differ in terms of gender, refraction, IOP or CDR (all, P≥0.071). In a multivariate model including age, gender and refraction as predictors of angle grade (open or narrow), only age was a significant predictor of angle grade (P=0.004). Conclusions A large proportion of Chinese-Americans in our study population with glaucoma or glaucoma suspicion had gonioscopically narrow angles. In multivariate analysis, patients with narrow angles were older than those with open angles but did not differ from them in terms of gender or refraction. Continued evaluation of angle closure glaucoma risk among Chinese-Americans is needed. PMID:19826385
Luna-Pizarro, Daniel; Amato, Dante; Arellano, Francisco; Hernández, Armando; López-Rojas, Pablo
2006-09-01
To compare the percutaneous patellar osteosynthesis system (PPOS) technique with open surgery for patella fractures. Randomized controlled trial. Referral orthopedic and trauma center. Fifty-three patients with displaced patellar fractures. Stabilization and fixation of patellar fractures with PPOS or open surgery. Knee-flexion and -extension angles, pain, surgical time, and assessment of knee function based on the Knee Society Clinical Rating Scale (KSCRS). Comparison of PPOS and open-surgery groups at 4 weeks showed the following: pain, 3.7 +/- 1.6 versus 6.2 +/- 1.4 arbitrary units, P < 0.001; flexion angle, 46 +/- 20.7 versus 12.7 +/- 6.0 degrees, P < 0.001; extension angle, -2.5 versus -3.8 degrees, P < 0.001. At 8 weeks, the following was demonstrated: pain, 1.3 +/- 1.6 versus 4.1 +/- 2.1 arbitrary units, P < 0.001; flexion angle, 87 +/- 17.3 versus 34 +/- 26 degrees, P < 0.001; extension angle, 0 versus -3 degrees, P < 0.001. Surgical time was 35.3 +/- 7.8 versus 66.2 +/- 14.1 minutes, P < 0.001. KSCRS assessment was 84 +/- 4 versus 70 +/- 8, P < 0.001 at 8 weeks; 85 +/- 2 versus 73 +/- 8, P < 0.001 at 12 months; and 85 +/- 1 versus 82 +/- 7, P = 0.246 at 24 months. Frequency of total complications (infections, fragment displacement, and wire-related pain) was significantly lower in the PPOS than in the open-surgery group (P < 0.02). PPOS for patella fractures was associated with shorter surgical time, less pain, better mobility angles, higher functional score up to 2 years, and a lower incidence of complications than open surgery.
Sokolis, Dimitrios P; Savva, Giannis D; Papadodima, Stavroula A; Kourkoulis, Stavros K
2017-03-01
The biomechanical response of the human aorta varies with axial location, but little is known about the respective variation of residual strains. Such data are available for common lab animals, but in the traditional opening angle measurement the aorta is considered as an ideal cylinder and average residual strains are measured, so that the spatial variations of local residual strains are not determined. The present study provides opening angle and residual strain data throughout the course and around the circumference of the aorta harvested during autopsy. Opening angle showed notable topographical variation; the highest value was at the top of aortic arch, declining abruptly toward the ascending aorta and to a near-constant value in the descending aorta, and rising in the abdominal aorta. The variation of curvature and of external but not internal residual stretch resembled that of opening angle. Extensive residual stress and wall thickness differences were evidenced among quadrants, with the more pre-stressed being also the thicker quadrants. Gender had overall minor effects, but aging led to increased parameters, occurring earlier in the distal aorta but at later stages becoming predominant proximally. Differences in caliber were pronounced in older subjects, unlike those in opening angle, residual stretches, and thickness that were striking in middle-aged subjects. By contrast, curvature decreased with aging in relation to the smaller percentwise opening angle differences. Detailed knowledge of the zero-stress/no-load geometry of the human aortic wall is critical for an in-depth understanding of aortic physiology, while providing the basis for comparison with disease. Copyright © 2016 Elsevier Ltd. All rights reserved.
Grover, Davinder S; Smith, Oluwatosin; Fellman, Ronald L; Godfrey, David G; Gupta, Aditi; Montes de Oca, Ildamaris; Feuer, William J
2018-05-01
The purpose of this study was to provide 24-month follow-up on surgical success and safety of an ab interno circumferential 360-degree trabeculotomy. Chart review of patients who underwent a gonioscopy-assisted transluminal trabeculotomy (GATT) procedure was performed by 4 of the authors (D.S.G., O.S., R.L.F., and D.G.G.). The surgery was performed in adults with various types of open-angle glaucoma with preoperative intraocular pressures (IOPs) of ≥18 mm Hg. In total, 198 patients aged 24 to 89 years underwent the GATT procedure with at least 18 months follow-up. Patients with primary open-angle glaucoma had an average IOP decrease of 9.2 mm Hg at 24 months with an average decrease of 1.43 glaucoma medications. The mean percentage of IOP decrease in these primary open-angle glaucoma groups at 24 months was 37.3%. In secondary open-angle glaucoma, at 24 months there was an average decrease in IOP of 14.1 mm Hg on an average of 2.0 fewer medications. The mean percentage of IOP decrease in the secondary open-angle glaucoma groups at 24 months was 49.8%. The cumulative proportion of failure at 24 months ranged from 0.18 to 0.48, depending on the group. In all 6 study groups, at all 5 postoperative time points (3, 6, 12, 18, and 24 mo) the mean IOP and reduction in glaucoma medications was significantly reduced from baseline (P<0.001) with the exception of one time point. The 24-month results demonstrate that GATT is relatively safe and effective in treating various forms of open-angle glaucoma. The long-term results for GATT are relatively equivalent to those previously reported for GATT and ab externo trabeculotomy studies.
Griffith, Joseph F; Goldberg, Jeffrey L
2016-03-01
To determine the frequency of optical coherence tomography (OCT) examinations compared with clinical examinations and visual field (VF) tests in patients with 5 types of glaucoma. A retrospective, longitudinal cohort study was conducted of 5154 patients treated between 2003 and 2010 at a single academic medical center. Patients were classified using billing records as having primary open-angle glaucoma, low-tension open-angle glaucoma (NTG), pigmentary open-angle glaucoma, chronic angle-closure glaucoma, or pseudoexfoliation glaucoma. Analysis of variance, χ test, and exact χ test were performed to identify associations between glaucoma type and test frequency. Pigmentary open-angle glaucoma and NTG patients had a higher rate of undergoing at least 2 VFs (94.4%, 94.9%), and chronic angle-closure glaucoma patients had a lower rate of undergoing at least 2 OCTs (25.3%) than all other glaucoma types. NTG patients also had the highest rate of undergoing at least 2 OCTs and at least 2 VFs (36.6%). Overall, the rate of clinical examinations (2.68 examinations/y) exceeded the rates of OCTs (1.39 examinations/y), which exceeded the rate of VF tests (1.24 tests/y). There were no differences in OCT frequency between glaucoma types (0.91 to 1.63 OCTs/y). Within each glaucoma diagnosis, patients had clinical examinations more frequently than OCTs and clinical examinations more frequently than VFs. Primary open-angle glaucoma and pseudoexfoliation glaucoma patients also had OCTs more frequently than VFs. More patients had at least 2 VF tests than at least 2 OCTs (4481 vs. 1679). The relative use of clinical examinations, VF testing, and OCT imaging varies among glaucoma diagnoses.
Bedi, Asheesh; Zaltz, Ira; De La Torre, Katrina; Kelly, Bryan T
2011-07-01
Whether open or arthroscopic techniques are employed, the goal of femoroacetabular impingement (FAI) surgery is to achieve impingement-free range of motion. While arthroscopic approaches have improved and gained popularity, an objective evaluation of the surgical correction achieved with this approach compared with open surgery remains to be defined in the literature. This study was undertaken to compare the efficacy of arthroscopic osteoplasty and open surgical dislocation in treating FAI dysmorphology in a consecutive series of patients. Cohort study; Level of evidence, 3. Surgical treatment was performed in 60 male patients under 40 years of age for symptomatic FAI refractory to nonoperative management. Patients were matched (not randomized) to treatment groups: 30 patients (15 left and 15 right hips) underwent arthroscopic cam and/or rim osteoplasty with labral debridement and/or refixation by an arthroscopic surgeon; and 30 (14 left and 16 right hips) underwent open surgical dislocation, cam and/or rim osteoplasty, and labral debridement or refixation by a hip preservation surgeon. Anteroposterior (AP) pelvis and extended-neck (Dunn) lateral radiographs were obtained and the depth of resection and arc of resection were measured by assessment of anterior femoral head-neck offset, AP and lateral α angle, and β angle on preoperative and postoperative radiographs. In the arthroscopic group, the extended-neck lateral α angle was reduced by a mean of 17.2° (28.3%, P < .05), AP α angle was reduced by a mean of 12.6° (16.8%), anterior head-neck offset improved 5.0 mm (111%, P < .05), and β angle increased by a mean of 23.1°. In the open dislocation group, the extended-neck lateral α angle was reduced by a mean of 21.2° (30.7%, P < .05), AP α angle was reduced by a mean of 20.1° (25.7%), anterior head-neck offset improved 6.56 mm (108%, P < .05), and β angle increased by a mean of 18.35°. Arthroscopic osteoplasty can restore head-neck offset and achieve similar depth, arc, and proximal-distal resection with comparable efficacy to open surgical dislocation for anterior and anterosuperior cam and focal rim impingement deformity. The open technique, however, may allow greater correction of posterosuperior loss of femoral offset and may be favorable for FAI patterns that demonstrate considerable proximal femoral deformity on AP radiographs.
Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun; Seong, Gong Je
2017-03-01
To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R²=0.404). Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors.
Lee, Wonseok; Bae, Hyoung Won; Lee, Si Hyung; Kim, Chan Yun
2017-01-01
Purpose To assess the accuracy of intraocular lens (IOL) power prediction for cataract surgery with open angle glaucoma (OAG) and to identify preoperative angle parameters correlated with postoperative unpredicted refractive errors. Materials and Methods This study comprised 45 eyes from 45 OAG subjects and 63 eyes from 63 non-glaucomatous cataract subjects (controls). We investigated differences in preoperative predicted refractive errors and postoperative refractive errors for each group. Preoperative predicted refractive errors were obtained by biometry (IOL-master) and compared to postoperative refractive errors measured by auto-refractometer 2 months postoperatively. Anterior angle parameters were determined using swept source optical coherence tomography. We investigated correlations between preoperative angle parameters [angle open distance (AOD); trabecular iris surface area (TISA); angle recess area (ARA); trabecular iris angle (TIA)] and postoperative unpredicted refractive errors. Results In patients with OAG, significant differences were noted between preoperative predicted and postoperative real refractive errors, with more myopia than predicted. No significant differences were recorded in controls. Angle parameters (AOD, ARA, TISA, and TIA) at the superior and inferior quadrant were significantly correlated with differences between predicted and postoperative refractive errors in OAG patients (-0.321 to -0.408, p<0.05). Superior quadrant AOD 500 was significantly correlated with postoperative refractive differences in multivariate linear regression analysis (β=-2.925, R2=0.404). Conclusion Clinically unpredicted refractive errors after cataract surgery were more common in OAG than in controls. Certain preoperative angle parameters, especially AOD 500 at the superior quadrant, were significantly correlated with these unpredicted errors. PMID:28120576
Lin, Shan C.; Masis, Marisse; Porco, Travis C.; Pasquale, Louis R.
2017-01-01
Purpose To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. Methods This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. Results We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P<.001) in the narrower-angle group vs 2.2±3 mm Hg (14%, P<.001) in the wide-angle group (P=.027 for difference), as classified by gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P<.001) reduction vs 2.5±3 mm Hg (16%, P<.001) in the wide-angle group (P=.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year (P<.05 for all). Conclusions In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option. PMID:29147104
Lin, Shan C; Masis, Marisse; Porco, Travis C; Pasquale, Louis R
2017-08-01
To assess if narrower-angle status and anterior segment optical coherence tomography (AS-OCT) parameters can predict intraocular pressure (IOP) drop in primary open-angle glaucoma (POAG) patients after cataract surgery. This was a prospective case series of consecutive cataract surgery patients with POAG and no peripheral anterior synechiae (PAS) using a standardized postoperative management protocol. Preoperatively, patients underwent gonioscopy and AS-OCT. The same glaucoma medication regimen was resumed by 1 month. Potential predictors of IOP reduction included narrower-angle status by gonioscopy and angle-opening distance (AOD500) as well as other AS-OCT parameters. Mixed-effects regression adjusted for use of both eyes and other potential confounders. We enrolled 66 eyes of 40 glaucoma patients. The IOP reduction at 1 year was 4.2±3 mm Hg (26%, P <.001) in the narrower-angle group vs 2.2±3 mm Hg (14%, P <.001) in the wide-angle group ( P =.027 for difference), as classified by gonioscopy. By AOD500 classification, the narrower-angle group had 3.4±3 mm Hg (21%, P <.001) reduction vs 2.5±3 mm Hg (16%, P <.001) in the wide-angle group ( P =.031 for difference). When the entire cohort was assessed, iris thickness, iris area, and lens vault were correlated with increasing IOP reduction at 1 year ( P <.05 for all). In POAG eyes, cataract surgery lowered IOP to a greater degree in the narrower-angle group than in the wide-angle group, and parameters relating to iris thickness and area, as well as lens vault, were correlated with IOP reduction. These findings can guide ophthalmologists in their selection of cataract surgery as a potential management option.
Some Characteristics of Fuel Sprays from Open Nozzles
NASA Technical Reports Server (NTRS)
Rothrock, A M; Lee, D W
1930-01-01
The penetration and cone-angle of fuel sprays from open nozzles were recorded with the NACA Spray Photography Equipment. The results show that for injection systems in which the rate of pressure rise at the discharge orifice is high, open nozzles give spray-tip velocities and penetrations which compare favorably with those of closed nozzles. The spray cone-angle was the same for all tests, although open nozzles having different orifice diameters were used, and one nozzle was used both as an open and as a closed nozzle. In designing a fuel system using open nozzles, particular care must be taken to avoid air pockets. The check valve should be placed close to the discharge orifice.
Mondal, Lakshmikanta; Baidya, Krishnapada; Choudhury, Himadri; Roy, Rupam
2013-06-01
The purpose of the study was to evaluate the progression of glaucomatous field damage in patients with stable primary open angle glaucoma after an attack of myocardial infarction. In this case control study, 62 open angle glaucoma patients were selected and regularly followed up. Among 62 patients, 9 had an attack of myocardial infarction. The intra-ocular pressure and visual field progression of both the groups (myocardial infarction versus no myocardial infarction) were analysed. Three (33.3%) out of 9 patients who had suffered from myocardial infarction showed progressive visual field loss whereas only 9 (16.9%) out of 53 patients who did not suffer from myocardial infarction, showed progressive field changes. Both the groups had stable target intra-ocular pressure between 14 and 16 mm Hg. Myocardial infarction may adversely influence the progression of primary open angle glaucoma which is suspected to result from ischaemia induced neuronal loss and only control of intraocular pressure is not the only solution. We have to look for other drugs that prevents ischaemia induced neuronal damage.
MOJAVE - XIV. Shapes and opening angles of AGN jets
NASA Astrophysics Data System (ADS)
Pushkarev, A. B.; Kovalev, Y. Y.; Lister, M. L.; Savolainen, T.
2017-07-01
We present 15 GHz stacked VLBA images of 373 jets associated with active galactic nuclei (AGNs) having at least five observing epochs within a 20 yr time interval 1994-2015 from the Monitoring Of Jets in Active galactic nuclei with VLBA Experiments (MOJAVE) programme and/or its precursor, the 2-cm VLBA Survey. These data are supplemented by 1.4 GHz single-epoch VLBA observations of 135 MOJAVE AGNs to probe larger scale jet structures. The typical jet geometry is found to be close to conical on scales from hundreds to thousands of parsecs, while a number of galaxies show quasi-parabolic streamlines on smaller scales. A true jet geometry in a considerable fraction of AGNs appears only after stacking epochs over several years. The jets with significant radial accelerated motion undergo more active collimation. We have analysed total intensity jet profiles transverse to the local jet ridgeline and derived both apparent and intrinsic opening angles of the flows, with medians of 21.5° and 1.3°, respectively. The Fermi LAT-detected gamma-ray AGNs in our sample have, on average, wider apparent and narrower intrinsic opening angle, and smaller viewing angle than non-LAT-detected AGNs. We have established a highly significant correlation between the apparent opening angle and gamma-ray luminosity, driven by Doppler beaming and projection effects.
Gravity field error analysis for pendulum formations by a semi-analytical approach
NASA Astrophysics Data System (ADS)
Li, Huishu; Reubelt, Tilo; Antoni, Markus; Sneeuw, Nico
2017-03-01
Many geoscience disciplines push for ever higher requirements on accuracy, homogeneity and time- and space-resolution of the Earth's gravity field. Apart from better instruments or new observables, alternative satellite formations could improve the signal and error structure compared to Grace. One possibility to increase the sensitivity and isotropy by adding cross-track information is a pair of satellites flying in a pendulum formation. This formation contains two satellites which have different ascending nodes and arguments of latitude, but have the same orbital height and inclination. In this study, the semi-analytical approach for efficient pre-mission error assessment is presented, and the transfer coefficients of range, range-rate and range-acceleration gravitational perturbations are derived analytically for the pendulum formation considering a set of opening angles. The new challenge is the time variations of the opening angle and the range, leading to temporally variable transfer coefficients. This is solved by Fourier expansion of the sine/cosine of the opening angle and the central angle. The transfer coefficients are further applied to assess the error patterns which are caused by different orbital parameters. The simulation results indicate that a significant improvement in accuracy and isotropy is obtained for small and medium initial opening angles of single polar pendulums, compared to Grace. The optimal initial opening angles are 45° and 15° for accuracy and isotropy, respectively. For a Bender configuration, which is constituted by a polar Grace and an inclined pendulum in this paper, the behaviour of results is dependent on the inclination (prograde vs. retrograde) and on the relative baseline orientation (left or right leading). The simulation for a sun-synchronous orbit shows better results for the left leading case.
Flow field and performance characteristics of combustor diffusers: A basic study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hestermann, R.; Kim, S.; Ben Khaled, A.
1995-10-01
Results of a detailed study concerning the influence of geometric as well as fluid mechanic parameters o the performance of a plane model combustor diffuser in cold flow are presented. For a qualitative insight into the complex flow field inside the prediffuser, the sudden expansion region, and the flow field around the flame tube dome, results of a flow visualization study with the hydrogen bubble method as well as with the ink jet method are presented for different opening angles of the prediffuser and for different flame tube distances. Also, quantitative data from detailed measurements with LDV and conventional pressuremore » probes in a geometrically similar air-driven setup are presented. These data clearly demonstrate the effect of boundary layer thickness as well as the influence of different turbulence levels at the entry of the prediffuser on the performance characteristics of combustor diffusers. The possibility of getting an unseparated flow field inside the prediffuser even at large opening angles by appropriately matching the diffuser`s opening angle and the flame tube distance is demonstrated. Also, for flows with an increased turbulence level at the entrance--all other conditions held constant--an increased opening angle can be realized without experiencing flow separation. The comparison of the experimental data with predictions utilizing a finite-volume-code based on a body-fitted coordinate system for diffusers with an included total opening angle less than 18 deg demonstrates the capability of describing the flow field in combustor diffusers with reasonable accuracy.« less
Hong's grading for evaluating anterior chamber angle width.
Kim, Seok Hwan; Kang, Ja Heon; Park, Ki Ho; Hong, Chul
2012-11-01
To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width. The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT. A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01). Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.
Diffo Kaze, Arnaud; Maas, Stefan; Hoffmann, Alexander; Pape, Dietrich
2017-12-01
This study aimed to investigate, by means of finite element analysis, the effect of a drill hole at the end of a horizontal osteotomy to reduce the risk of lateral cortex fracture while performing an opening wedge high tibial osteotomy (OWHTO). The question was whether drilling a hole relieves stress and increases the maximum correction angle without fracture of the lateral cortex depending on the ductility of the cortical bone. Two different types of osteotomy cuts were considered; one with a drill hole (diameter 5 mm) and the other without the hole. The drill holes were located about 20 mm distally to the tibial plateau and 6 mm medially to the lateral cortex, such that the minimal thickness of the contralateral cortical bone was 5 mm. Based on finite element calculations, two approaches were used to compare the two types of osteotomy cuts considered: (1) Assessing the static strength using local stresses following the idea of the FKM-guideline, subsequently referred to as the "FKM approach" and (2) limiting the total strain during the opening of the osteotomy wedge, subsequently referred to as "strain approach". A critical opening angle leading to crack initiation in the opposite lateral cortex was determined for each approach and was defined as comparative parameter. The relation to bone aging was investigated by considering the material parameters of cortical bones from young and old subjects. The maximum equivalent (von-Mises) stress was smaller for the cases with a drill hole at the end of the osteotomy cut. The critical angle was approximately 1.5 times higher for the specimens with a drill hole compared to those without. This corresponds to an average increase of 50%. The calculated critical angle for all approaches is below 5°. The critical angle depends on the used approach, on patient's age and assumed ductility of the cortical bone. Drilling a hole at the end of the osteotomy reduces the stresses in the lateral cortex and increases the critical opening angle prior to cracking of the opposite cortex in specimen with small correction angles. But the difference from having a drill hole or not is not so significant, especially for older patients. The ductility of the cortical bone is the decisive parameter for the critical opening angle.
46 CFR 172.150 - Survival conditions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge of openings such.... (5) Side scuttles of the non-opening type. (b) Heel angle. (1) Except as described in paragraph (b)(2) of this section, the maximum angle of heel must not exceed 15 degrees (17 degrees if no part of the...
46 CFR 172.150 - Survival conditions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... waterline, in the final condition of sinkage, heel, and trim, must be below the lower edge of openings such.... (5) Side scuttles of the non-opening type. (b) Heel angle. (1) Except as described in paragraph (b)(2) of this section, the maximum angle of heel must not exceed 15 degrees (17 degrees if no part of the...
Ocular Biometrics of Myopic Eyes With Narrow Angles.
Chong, Gabriel T; Wen, Joanne C; Su, Daniel Hsien-Wen; Stinnett, Sandra; Asrani, Sanjay
2016-02-01
The purpose of this study was to compare the ocular biometrics between myopic patients with and without narrow angles. Patients with a stable myopic refraction (myopia worse than -1.00 D spherical equivalent) were prospectively recruited. Angle status was assessed using gonioscopy and biometric measurements were performed using an anterior segment optical coherence tomography and an IOLMaster. A total of 29 patients (58 eyes) were enrolled with 13 patients (26 eyes) classified as having narrow angles and 16 patients (32 eyes) classified as having open angles. Baseline demographics of age, sex, and ethnicity did not differ significantly between the 2 groups. The patients with narrow angles were on average older than those with open angles but the difference did not reach statistical significance (P=0.12). The central anterior chamber depth was significantly less in the eyes with narrow angles (P=0.05). However, the average lens thickness, although greater in the eyes with narrow angles, did not reach statistical significance (P=0.10). Refractive error, axial lengths, and iris thicknesses did not differ significantly between the 2 groups (P=0.32, 0.47, 0.15). Narrow angles can occur in myopic eyes. Routine gonioscopy is therefore recommended for all patients regardless of refractive error.
Energy Landscapes for the Self-Assembly of Supramolecular Polyhedra
NASA Astrophysics Data System (ADS)
Russell, Emily R.; Menon, Govind
2016-06-01
We develop a mathematical model for the energy landscape of polyhedral supramolecular cages recently synthesized by self-assembly (Sun et al. in Science 328:1144-1147, 2010). Our model includes two essential features of the experiment: (1) geometry of the organic ligands and metallic ions; and (2) combinatorics. The molecular geometry is used to introduce an energy that favors square-planar vertices (modeling {Pd}^{2+} ions) and bent edges with one of two preferred opening angles (modeling boomerang-shaped ligands of two types). The combinatorics of the model involve two-colorings of edges of polyhedra with four-valent vertices. The set of such two-colorings, quotiented by the octahedral symmetry group, has a natural graph structure and is called the combinatorial configuration space. The energy landscape of our model is the energy of each state in the combinatorial configuration space. The challenge in the computation of the energy landscape is a combinatorial explosion in the number of two-colorings of edges. We describe sampling methods based on the symmetries of the configurations and connectivity of the configuration graph. When the two preferred opening angles encompass the geometrically ideal angle, the energy landscape exhibits a very low-energy minimum for the most symmetric configuration at equal mixing of the two angles, even when the average opening angle does not match the ideal angle.
Satellite-Tracking Millimeter-Wave Reflector Antenna System For Mobile Satellite-Tracking
NASA Technical Reports Server (NTRS)
Densmore, Arthur C. (Inventor); Jamnejad, Vahraz (Inventor); Woo, Kenneth E. (Inventor)
2001-01-01
A miniature dual-band two-way mobile satellite-tracking antenna system mounted on a movable vehicle includes a miniature parabolic reflector dish having an elliptical aperture with major and minor elliptical axes aligned horizontally and vertically, respectively, to maximize azimuthal directionality and minimize elevational directionality to an extent corresponding to expected pitch excursions of the movable ground vehicle. A feed-horn has a back end and an open front end facing the reflector dish and has vertical side walls opening out from the back end to the front end at a lesser horn angle and horizontal top and bottom walls opening out from the back end to the front end at a greater horn angle. An RF circuit couples two different signal bands between the feed-horn and the user. An antenna attitude controller maintains an antenna azimuth direction relative to the satellite by rotating it in azimuth in response to sensed yaw motions of the movable ground vehicle so as to compensate for the yaw motions to within a pointing error angle. The controller sinusoidally dithers the antenna through a small azimuth dither angle greater than the pointing error angle while sensing a signal from the satellite received at the reflector dish, and deduces the pointing angle error from dither-induced fluctuations in the received signal.
A satellite-tracking millimeter-wave reflector antenna system for mobile satellite-tracking
NASA Technical Reports Server (NTRS)
Densmore, Arthur C. (Inventor); Jamnejad, Vahraz (Inventor); Woo, Kenneth E. (Inventor)
1995-01-01
A miniature dual-band two-way mobile satellite tracking antenna system mounted on a movable ground vehicle includes a miniature parabolic reflector dish having an elliptical aperture with major and minor elliptical axes aligned horizontally and vertically, respectively, to maximize azimuthal directionality and minimize elevational directionality to an extent corresponding to expected pitch excursions of the movable ground vehicle. A feed-horn has a back end and an open front end facing the reflector dish and has vertical side walls opening out from the back end to the front end at a lesser horn angle and horizontal top and bottom walls opening out from the back end to the front end at a greater horn angle. An RF circuit couples two different signal bands between the feed-horn and the user. An antenna attitude controller maintains an antenna azimuth direction relative to the satellite by rotating it in azimuth in response to sensed yaw motions of the movable ground vehicle so as to compensate for the yaw motions to within a pointing error angle. The controller sinusoidally dithers the antenna through a small azimuth dither angle greater than the pointing error angle while sensing a signal from the satellite received at the reflector dish, and deduces the pointing angle error from dither-induced fluctuations in the received signal.
Characteristics of Upper Quadrant Posture of Young Women with Temporomandibular Disorders
Uritani, Daisuke; Kawakami, Tetsuji; Inoue, Tomohiro; Kirita, Tadaaki
2014-01-01
[Purpose] This study aimed to investigate the characteristics of upper quadrant posture of young women with temporomandibular disorders. [Subjects] The participants were 19 female patients with temporomandibular disorders (patient group: mean age, 30.1 years) and 14 controls (control group: mean age, 24.6 years). [Methods] Outcome measures were the neck inclination angle (formed by a line connecting C7 and the ear tragus with a horizontal line), the angle of the shoulder (formed by a line connecting C7 and the acromial angle with a horizontal line), the cranial rotation angle (formed by a line connecting the ear tragus and the corner of the eye with a horizontal line), and the neck-length/shoulder-width ratio [the ratio of the neck length (from C7 to the tragus) to the width of the shoulder between the acromial angle]. The maximum range of mouth opening was measured using a scale. [Results] The neck inclination angle and maximum range of mouth opening were significantly smaller in the patient group than in the control group. No significant differences were observed in the other outcome measures between the two groups. [Conclusion] Temporomandibular disorders with limited mouth opening in young females are associated with the head position relative to the trunk. PMID:25276038
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goldstein, Adam; Connaughton, Valerie; Briggs, Michael S.
We present a method to estimate the jet opening angles of long duration gamma-ray bursts (GRBs) using the prompt gamma-ray energetics and an inversion of the Ghirlanda relation, which is a correlation between the time-integrated peak energy of the GRB prompt spectrum and the collimation-corrected energy in gamma-rays. The derived jet opening angles using this method and detailed assumptions match well with the corresponding inferred jet opening angles obtained when a break in the afterglow is observed. Furthermore, using a model of the predicted long GRB redshift probability distribution observable by the Fermi Gamma-ray Burst Monitor (GBM), we estimate themore » probability distributions for the jet opening angle and rest-frame energetics for a large sample of GBM GRBs for which the redshifts have not been observed. Previous studies have only used a handful of GRBs to estimate these properties due to the paucity of observed afterglow jet breaks, spectroscopic redshifts, and comprehensive prompt gamma-ray observations, and we potentially expand the number of GRBs that can be used in this analysis by more than an order of magnitude. In this analysis, we also present an inferred distribution of jet breaks which indicates that a large fraction of jet breaks are not observable with current instrumentation and observing strategies. We present simple parameterizations for the jet angle, energetics, and jet break distributions so that they may be used in future studies.« less
NASA Technical Reports Server (NTRS)
Ford, Donald B. (Inventor)
2004-01-01
A sandwich core comprises two faceplates separated by a plurality of cells. The cells are comprised of walls positioned at oblique angles relative to a perpendicular axis extending through the faceplates. The walls preferably form open cells and are constructed from open cells and are constructed from rows of ribbons. The walls may be obliquely angled relative to more than one plane extending through the perpendicular axis.
Heterogeneous growth-induced prestrain in the heart
Genet, M.; Rausch, M.; Lee, L.C.; Choy, S.; Zhao, X.; Kassab, G.S.; Kozerke, S.; Guccione, J.M.; Kuhl, E.
2015-01-01
Even when entirely unloaded, biological structures are not stress-free, as shown by Y.C. Fung’s seminal opening angle experiment on arteries and the left ventricle. As a result of this prestrain, subject-specific geometries extracted from medical imaging do not represent an unloaded reference configuration necessary for mechanical analysis, even if the structure is externally unloaded. Here we propose a new computational method to create physiological residual stress fields in subject-specific left ventricular geometries using the continuum theory of fictitious configurations combined with a fixed-point iteration. We also reproduced the opening angle experiment on four swine models, to characterize the range of normal opening angle values. The proposed method generates residual stress fields which can reliably reproduce the range of opening angles between 8.7±1.8 and 16.6 ± 13.7 as measured experimentally. We demonstrate that including the effects of prestrain reduces the left ventricular stiffness by up to 40%, thus facilitating the ventricular filling, which has a significant impact on cardiac function. This method can improve the fidelity of subject-specific models to improve our understanding of cardiac diseases and to optimize treatment options. PMID:25913241
Refraction and scattering of sound by a shear layer
NASA Technical Reports Server (NTRS)
Schlinker, R. H.; Amiet, R. K.
1980-01-01
The angle and amplitude changes for acoustic waves refracted by a circular open jet shear layer were determined. The generalized refraction theory was assessed experimentally for on axis and off axis acoustic source locations as source frequency varied from 1 kHz to 10 kHz and free stream Mach number varied from 0.1 to 0.4. Angle and amplitude changes across the shear layer show good agreement with theory. Experiments confirm that the refraction theory is independent of shear layer thickness, acoustic source frequency, and source type. A generalized theory is, thus, available for correcting far field noise data acquired in open jet test facilities. The effect of discrete tone scattering by the open jet turbulent shear layer was also studied. Scattering effects were investigated over the same Mach number range as frequency varied from 5 kHz to 15 kHz. Attenuation of discrete tone amplitude and tone broadening were measured as a function of acoustic source position and radiation angle. Scattering was found to be stronger at angles close to the open jet axis than at 90 deg, and becomes stronger as the acoustic source position shifts downstream. A scattering analysis provided an estimate of the onset of discrete tone scattering.
Retrobulbar hemodynamic parameters in men and women with open angle glaucoma.
Marjanović, Ivan; Marjanović, Marija; Gvozdenović, Ranko; Risović, Dušica
2014-12-01
Several factors may have influence on systemic circulation. Additionally, peripheral circulation also demonstrates sex differences, in young women presenting significantly lower finger blood flow in comparison to men of the same age, a finding that disappears in women after menopause. The aim of this study was to compare the retrobulbar hemodynamic parameters measured by means of color Doppler imaging in women and men with open-angle glaucoma and elevated intraocular pressure. A total of 52 eyes from 52 open-angle glaucoma (OAG) patients, with elevated intraocular pressure (lOP), were included in this cross-sectional study. Peak-systolic velocity (PSV), end-diastolic velocity (EDV), and Pourcelot resistivity index (RI) were assessed in the ophtalmic artery (OA), central retinal artery (CRA), and posterior cilliary arteries (PCA). IOP was measured both with Goldmann Applanation tonometer (GAT) and with the dynamic contour tonometer (DCT), three times respectively. Ocular pulse amplitude (OPA) appeared during the DCT measurement. The retrobulbar hemodynamic parameters did not show any difference between men and post-menopausal women. The results of our study did not find any difference between sexes in patients with open-angle glaucoma and elevated intraocular pressure.
Ao, Dongyang; Li, Yuanhao; Hu, Cheng; Tian, Weiming
2017-12-22
The dihedral corner reflectors are the basic geometric structure of many targets and are the main contributions of radar cross section (RCS) in the synthetic aperture radar (SAR) images. In stealth technologies, the elaborate design of the dihedral corners with different opening angles is a useful approach to reduce the high RCS generated by multiple reflections. As bistatic synthetic aperture sensors have flexible geometric configurations and are sensitive to the dihedral corners with different opening angles, they specially fit for the stealth target detections. In this paper, the scattering characteristic of dihedral corner reflectors is accurately analyzed in bistatic synthetic aperture images. The variation of RCS with the changing opening angle is formulated and the method to design a proper bistatic radar for maximizing the detection capability is provided. Both the results of the theoretical analysis and the experiments show the bistatic SAR could detect the dihedral corners, under a certain bistatic angle which is related to the geometry of target structures.
Accurate Analysis of Target Characteristic in Bistatic SAR Images: A Dihedral Corner Reflectors Case
Ao, Dongyang; Hu, Cheng; Tian, Weiming
2017-01-01
The dihedral corner reflectors are the basic geometric structure of many targets and are the main contributions of radar cross section (RCS) in the synthetic aperture radar (SAR) images. In stealth technologies, the elaborate design of the dihedral corners with different opening angles is a useful approach to reduce the high RCS generated by multiple reflections. As bistatic synthetic aperture sensors have flexible geometric configurations and are sensitive to the dihedral corners with different opening angles, they specially fit for the stealth target detections. In this paper, the scattering characteristic of dihedral corner reflectors is accurately analyzed in bistatic synthetic aperture images. The variation of RCS with the changing opening angle is formulated and the method to design a proper bistatic radar for maximizing the detection capability is provided. Both the results of the theoretical analysis and the experiments show the bistatic SAR could detect the dihedral corners, under a certain bistatic angle which is related to the geometry of target structures. PMID:29271917
: "\\f106"; /* open - switch to fa-angle-up */ } @media(min-width:768px) { /* top level open */ } } /* top level open hover */ .navbar-dark .navbar-nav > li.open > a:hover, .navbar-dark .navbar-nav :768px) { /* top level open hover desktop*/ .navbar-dark .navbar-nav > li.open > a:hover, .navbar
NASA Technical Reports Server (NTRS)
Arabian, Donald D.; Runckel, Jack F.; Reid, Charles F, Jr.
1961-01-01
Measurements of the normal force and chord force were made on the slats of a sting-mounted wing-fuselage model through a Mach number range of 0.60 to 1.03 and at angles of attack from 0 to 20 deg at subsonic speeds and from 0 to 8 deg at Mach number 1.03. The 20-percent-chord tapered leading-edge slats extended from 25 to 95 percent of the semispan and consisted of five segments. The model wing had 45 deg sweep, an aspect ratio of 3.56, a taper ratio of 0.3, and NACA 64(06)AO07 airfoil sections. Slat forces and moments were determined for the slats in the almost-closed and open positions for spanwise extents of 35 to 95 percent and 46 to 95 percent of the semispan. The results of the investigation showed little change in the slat maximum force and moment coefficients with Mach number. The coefficients for the open and almost-closed slat positions had similar variations with angle of attack. The loads on the individual slat segments were found to increase toward the tip for moderate angles of attack and decrease toward the tip for high angles of attack. An analysis of the opening and closing characteristics of aerodynamically operated slats opening on a circular-arc path is included.
A mechanical analysis of conduit arteries accounting for longitudinal residual strains.
Wang, Ruoya; Gleason, Rudolph L
2010-04-01
Identification of an appropriate stress-free reference configuration is critically important in providing a reasonable prediction of the intramural stress distribution when performing biomechanical analyses on arteries. The stress-free state is commonly approximated as a radially cut ring that typically opens into a nearly circular sector, relieving much of the circumferential residual strains that exist in the traction-free configuration. An opening angle is often used to characterize this sector. In this study, we first present experimental results showing significant residual deformations in the longitudinal direction of two commonly studied arteries in the pig: the common carotid artery and the left anterior descending coronary artery. We concluded that a radially cut ring cannot completely describe the stress-free state of the arteries. Instead, we propose the use of a longitudinal opening angle, in conjunction with the traditional circumferential opening angle, to experimentally quantify the stress-free state of an artery. Secondly, we propose a new kinematic model to account for the addition of longitudinal residual strains through employing the longitudinal opening angle and performed a stress analysis. We found that with the inclusion of longitudinal residual strains in the stress analysis, the predicted circumferential stress gradient was decreased by 3-fold and the predicted longitudinal stress gradient was increased by 5.7-fold. Thus, inclusion of longitudinal residual strains has a significant effect on the predicted stress distribution in arteries.
Nakamine, Sakari; Sakai, Hiroshi; Arakaki, Yoshikuni; Yonahara, Michiko; Kaiya, Tadayoshi
2018-01-01
To study the effect of the internal fixation lamp on anterior chamber width measured by anterior segment optical coherence tomography. In a prospective cross sectional observational study, consecutive 22 right eyes of 22 patients (4 men and 18 women) with suspected primary angle closure underwent swept source domain anterior segment optical coherence tomography (AS-OCT), (CASIA SS-1000, Tomey, Nagoya, Japan). Anterior chamber parameters of angle opening distance (AOD), trabecular-iris angle (TIA), angle recess area (ARA) at 500 or 750 µm from scleral spur and pupil diameter were measured by AS-OCT in a three-dimensional mode in 4 quadrants (superior, inferior, temporal and nasal) in dark room setting both with and without internal fixation lamp. Anterior segment parameters of AOD 500 in superior, inferior and temporal quadrants, AOD 750 at superior and nasal, TIA 500 at superior, and inferior and TIA 750 at superior and nasal, and ARA 500 or 750 at superior and inferior with internal fixation lamp were greater and the pupil diameter was significantly (all P < 0.05, paired t test) smaller than when measured without fixation lamp. Internal fixation lamp of the anterior segment OCT makes the pupil constrict and angle wider. When using AS-OCT with usual setting with internal fixation lamp on with eyes in which the anterior chamber angle is narrow but open, it is recommended that the internal fixation lamp be turned off to ensure a clear indication as to whether the angle is open or closed in the dark.
Davydova, N G; Kuznetsova, T P; Borisova, S A; Abdulkadyrova, M Zh
2006-01-01
The paper presents the results of an investigation of the effect of the nootropic agents pantogam and nooclerine on visual functions in patients with primary open-angle glaucoma. These agents have been found to have a beneficial effect on the functional activity of the retina and optic nerve, light sensitivity, hemo- and hydrodynamics of the eye.
Evangelho, Karine; Mogilevskaya, Maria; Losada-Barragan, Monica; Vargas-Sanchez, Jeinny Karina
2017-12-30
Glaucoma is the leading cause of blindness in humans, affecting 2% of the population. This disorder can be classified into various types including primary, secondary, glaucoma with angle closure and with open angle. The prevalence of distinct types of glaucoma differs for each particular region of the world. One of the most common types of this disease is primary open-angle glaucoma (POAG), which is a complex inherited disorder characterized by progressive retinal ganglion cell death, optic nerve head excavation and visual field loss. Nowadays, POAG is considered an optic neuropathy, while intraocular pressure is proposed to play a fundamental role in its pathophysiology and especially in optic disk damage. However, the exact mechanism of optic nerve head damage remains a topic of debate. This literature review aims to bring together the information on the pathophysiology of primary open-angle glaucoma, particularly focusing on neuroinflammatory mechanisms leading to the death of the retinal ganglion cell. A literature search was done on PubMed using key words including primary open-angle glaucoma, retinal ganglion cells, Müller cells, glutamate, glial cells, ischemia, hypoxia, exitotoxicity, neuroinflammation, axotomy and neurotrophic factors. The literature was reviewed to collect the information published about the pathophysiologic mechanisms of RGC death in the POAG, from a neuroinflammatory and neurotoxicity perspective. Proposed mechanisms for glaucomatous damage are a result of pressure in RGC followed by ischemia, hypoxia of the ONH, and consequently death due to glutamate-induced excitotoxicity, deprivation of energy and oxygen, increase in levels of inflammatory mediators and alteration of trophic factors flow. These events lead to blockage of anterograde and retrograde axonal transport with ensuing axotomy and eventually blindness. The damage to ganglion cells and eventually glaucomatous injury can occur via various mechanisms including baric trauma, ischemia and impact of metabolic toxins, which triggers an inflammatory process and secondary degeneration in the ONH.
Ertas, Burak; Gunaydin, Rıza Onder; Unal, Omer Faruk
2015-04-01
To share our experience involving seven patients with type II first branchial cleft anomalies (hereafter, type II anomalies), to determine whether the location of the external fistula openings of the anomalies are associated with the location of the facial nerve tract, and elucidate the relationship between the location of the fistula opening and the facial nerve. The medical records of seven patients who underwent surgery from 2005 to 2013 for type II anomalies were retrospectively examined. The relationship between the fistula opening and the facial nerve was evaluated in each patient with respect to whether the fistula opening was superior or inferior to the mandibular angle. All patients underwent partial parotidectomy, facial nerve exposure, and total excision of the mass together with connection of a small cuff of the external auditory canal skin to the fistula tract. The fistula tracts were located medially to the facial nerve in two patients, and both fistulae had openings inferior to the mandibular angle. The fistula tracts were located laterally to the facial nerve in the remaining five patients: one patient had no external opening, one had an opening inferior to the mandibular angle, and the remaining three had openings superior to the mandibular angle. Because type II anomalies are rare, their diagnosis is difficult. Surgery of such lesions is challenging and associated with a high risk due to their proximity to the facial nerve. We believe that the location of the fistula opening may help to identify the relationship between the anomalous lesion and facial nerve. Studies involving larger series of cases are needed to confirm our hypothesis; however, because of the rarity of this specific anomaly, it will not be easy to compile a large number of cases. We believe that our study will encourage further investigation on this subject. Copyright © 2014. Published by Elsevier Ireland Ltd.
Balouch, F; Jalalian, E; Nikkheslat, M; Ghavamian, R; Toopchi, Sh; Jallalian, F; Jalalian, S
2013-01-01
Statement of Problem: Various impression techniques have different effects on the accuracy of final cast dimensions. Meanwhile; there are some controversies about the best technique. Purpose: This study was performed to compare two kinds of implant impression methods (open tray and closed tray) on 15 degree angled implants. Materials and Method: In this experimental study, a steel model with 8 cm in diameter and 3 cm in height were produced with 3 holes devised inside to stabilize 3 implants. The central implant was straight and the other two implants were 15° angled. The two angled implants had 5 cm distance from each other and 3.5 cm from the central implant. Dental stone, high strength (type IV) was used for the main casts. Impression trays were filled with poly ether, and then the two impression techniques (open tray and closed tray) were compared. To evaluate positions of the implants, each cast was analyzed by CMM device in 3 dimensions (x,y,z). Differences in the measurements obtained from final casts and laboratory model were analyzed using t-Test. Results: The obtained results indicated that closed tray impression technique was significantly different in dimensional accuracy when compared with open tray method. Dimensional changes were 129 ± 37μ and 143.5 ± 43.67μ in closed tray and open tray, while coefficient of variation in closed- tray and open tray were reported to be 27.2% and 30.4%, respectively. Conclusion: Closed impression technique had less dimensional changes in comparison with open tray method, so this study suggests that closed tray impression technique is more accurate. PMID:24724130
Holographic Jet Shapes and their Evolution in Strongly Coupled Plasma
NASA Astrophysics Data System (ADS)
Brewer, Jasmine; Rajagopal, Krishna; Sadofyev, Andrey; van der Schee, Wilke
2017-11-01
Recently our group analyzed how the probability distribution for the jet opening angle is modified in an ensemble of jets that has propagated through an expanding cooling droplet of plasma [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603]. Each jet in the ensemble is represented holographically by a string in the dual 4+1- dimensional gravitational theory with the distribution of initial energies and opening angles in the ensemble given by perturbative QCD. In [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603], the full string dynamics were approximated by assuming that the string moves at the speed of light. We are now able to analyze the full string dynamics for a range of possible initial conditions, giving us access to the dynamics of holographic jets just after their creation. The nullification timescale and the features of the string when it has nullified are all results of the string evolution. This emboldens us to analyze the full jet shape modification, rather than just the opening angle modification of each jet in the ensemble as in [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603]. We find the result that the jet shape scales with the opening angle at any particular energy. We construct an ensemble of dijets with energies and energy asymmetry distributions taken from events in proton-proton collisions, opening angle distribution as in [K. Rajagopal, A. V. Sadofyev, W. van der Schee, Phys. Rev. Lett. 116 (2016) 211603], and jet shape taken from proton-proton collisions and scaled according to our result. We study how these observables are modified after we send the ensemble of dijets through the strongly-coupled plasma.
Using Digital Technology to See Angles from Different Angles. Part 2: Openings and Turns
ERIC Educational Resources Information Center
Host, Erin; Baynham, Emily; McMaster, Heather
2015-01-01
Ever wondered how to use technology to teach angles? This article follows on from an earlier article published last year, providing a range of ideas for integrating technology and concrete materials with the teaching of angle concepts. The authors also provide a comprehensive list of free online games and learning objects that can be used to teach…
Minimally Invasive and Open Distal Chevron Osteotomy for Mild to Moderate Hallux Valgus.
Brogan, Kit; Lindisfarne, Edward; Akehurst, Harold; Farook, Usama; Shrier, Will; Palmer, Simon
2016-11-01
Minimally invasive surgical (MIS) techniques are increasingly being used in foot and ankle surgery but it is important that they are adopted only once they have been shown to be equivalent or superior to open techniques. We believe that the main advantages of MIS are found in the early postoperative period, but in order to adopt it as a technique longer-term studies are required. The aim of this study was to compare the 2-year outcomes of a third-generation MIS distal chevron osteotomy with a comparable traditional open distal chevron osteotomy for mild-moderate hallux valgus. Our null hypothesis was that the 2 techniques would yield equivalent clinical and radiographic results at 2 years. This was a retrospective cohort study. Eighty-one consecutive feet (49 MIS and 32 open distal chevron osteotomies) were followed up for a minimum 24 months (range 24-58). All patients were clinically assessed using the Manchester-Oxford Foot Questionnaire. Radiographic measures included hallux valgus angle, the intermetatarsal angle, hallux interphalangeal angle, metatarsal phalangeal joint angle, distal metatarsal articular angle, tibial sesamoid position, shape of the first metatarsal head, and plantar offset. Statistical analysis was done using Student t test or Wilcoxon rank-sum test for continuous data and Pearson chi-square test for categorical data. Clinical and radiologic postoperative scores in all domains were substantially improved in both groups (P < .001), but there was no statistically significant difference in improvement of any domain between open and MIS groups (P > .05). There were no significant differences in complications between the 2 groups ( > .5). The midterm results of this third-generation technique show that it was a safe procedure with good clinical outcomes and comparable to traditional open techniques for symptomatic mild-moderate hallux valgus. Level III, retrospective comparative study. © The Author(s) 2016.
The Prevalence of Age-Related Eye Diseases and Visual Impairment in Aging: Current Estimates
Klein, Ronald; Klein, Barbara E. K.
2013-01-01
Purpose. To examine prevalence of five age-related eye conditions (age-related cataract, AMD, open-angle glaucoma, diabetic retinopathy [DR], and visual impairment) in the United States. Methods. Review of published scientific articles and unpublished research findings. Results. Cataract, AMD, open-angle glaucoma, DR, and visual impairment prevalences are high in four different studies of these conditions, especially in people over 75 years of age. There are disparities among racial/ethnic groups with higher age-specific prevalence of DR, open-angle glaucoma, and visual impairment in Hispanics and blacks compared with whites, higher prevalence of age-related cataract in whites compared with blacks, and higher prevalence of late AMD in whites compared with Hispanics and blacks. The estimates are based on old data and do not reflect recent changes in the distribution of age and race/ethnicity in the United States population. There are no epidemiologic estimates of prevalence for many visually-impairing conditions. Conclusions. Ongoing prevalence surveys designed to provide reliable estimates of visual impairment, AMD, age-related cataract, open-angle glaucoma, and DR are needed. It is important to collect objective data on these and other conditions that affect vision and quality of life in order to plan for health care needs and identify areas for further research. PMID:24335069
Open-angle glaucoma in the Petit Basset Griffon Vendeen.
Bedford, Peter G C
2017-03-01
To report the prevalence and clinical characteristics of an open-angle glaucoma in Petit Basset Griffon Vendeen (PBGV) dogs in the United Kingdom (UK). At breed society clinics extending over a 6-year period, 366 dogs of varying ages and both sexes were clinically examined for signs of glaucoma using slit-lamp biomicroscopy, indirect and direct ophthalmoscopy, tonometry, and gonioscopy. The prevalence of glaucoma was 10.4% (38 dogs). Clinical signs of the disease presented from 3 years of age onwards, the commonest initial feature being the elevation of intraocular pressure (IOP) in 15 dogs (39.4%). In addition to elevated IOP, another 13 dogs (34.2%) presented with other features of glaucoma, some with lens subluxation and globe enlargement and all with possible or known vision defects. In the remaining 10 dogs (26.3%), phacodonesis or lens subluxation was observed before subsequent elevation of IOP. High prevalence and similarity to the primary open-angle glaucoma (POAG) seen in the Beagle and Elkhound breeds indicate that an open-angle glaucoma is present in the PBGV in the UK and that this disease may be genetically determined in this breed. Although increased IOP is the commonest early diagnostic feature, lens instability prior to an increase in IOP may be part of the clinical picture. © 2016 American College of Veterinary Ophthalmologists.
Kocatürk, Tolga; Bekmez, Sinan; Katrancı, Merve; Çakmak, Harun; Dayanır, Volkan
2015-01-01
To evaluate visual field progression with trend and event analysis in open angle glaucoma patients under treatment. Fifteen year follow-up results of 408 eyes of 217 glaucoma patients who were followed at Adnan Menderes University, Department of Ophthalmology between 1998 and 2013 were analyzed retrospectively. Visual field data were collected for Mean Deviation (MD), Visual Field Index (VFI), and event occurrence. There were 146 primary open-angle glaucoma (POAG), 123 pseudoexfoliative glaucoma (XFG) and 139 normal tension glaucoma (NTG) eyes. MD showed significant change in all diagnostic groups (p<0.001). The difference of VFI between first and last examinations were significantly different in POAG (p<0.001), and XFG (p<0.003) but not in NTG. VFI progression rates were -0.3, -0.43, and -0.2 % loss/year in treated POAG, XFG, and NTG, respectively. The number of empty triangles were statistically different between POAG-NTG (p=0.001), and XFG-NTG (p=0.002) groups. The number of half-filled (p=0.002), and full-filled (p=0.010) triangles were significantly different between XFG-NTG groups. Functional long-term follow-up of glaucoma patients can be monitored with visual field indices. We herein report our fifteen year follow-up results in open angle glaucoma.
Economic impact of primary open-angle glaucoma in Australia.
Dirani, Mohamed; Crowston, Jonathan G; Taylor, Penny S; Moore, Peter T; Rogers, Sophie; Pezzullo, M Lynne; Keeffe, Jill E; Taylor, Hugh R
2011-01-01
Glaucoma is the World's leading cause of irreversible blindness, and poses serious public health and economic concerns. Review. Published randomized trials and population-based studies since 1985. We report the economic impact of primary open-angle glaucoma and model the effect of changes in detection rates and management strategies. The cost-effectiveness of different interventions to prevent vision loss from primary open-angle glaucoma was measured in terms of financial cost (Australian dollars) and disability-adjusted life years. The prevalence of glaucoma in Australia is expected to increase from 208 000 in 2005 to 379 000 in 2025 because of the aging population. Health system costs over the same time period are estimated to increase from $AU355 million to $AU784 million. Total costs (health system costs, indirect costs and costs of loss of well-being) will increase from $AU1.9 billion to $AU4.3 billion in Australia. Primary open-angle glaucoma poses a significant economic burden, which will increase substantially by 2025. This dynamic model provides a valuable tool for ongoing policy formulation and determining the economic impact of interventions to better prevent visual impairment and blindness from glaucoma. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.
Investigation of Blade Angle of an Open Cross-Flow Runner
NASA Astrophysics Data System (ADS)
Katayama, Yusuke; Iio, Shouichiro; Veerapun, Salisa; Uchiyama, Tomomi
2015-04-01
The aim of this study was to develop a nano-hydraulic turbine utilizing drop structure in irrigation channels or industrial waterways. This study was focused on an open-type cross-flow turbine without any attached equipment for cost reduction and easy maintenance. In this study, the authors used an artificial indoor waterfall as lab model. Test runner which is a simple structure of 20 circular arc-shaped blades sandwiched by two circular plates was used The optimum inlet blade angle and the relationship between the power performance and the flow rate approaching theoretically and experimentally were investigated. As a result, the optimum inlet blade angle due to the flow rate was changed. Additionally, allocation rate of power output in 1st stage and 2nd stage is changed by the blade inlet angle.
Lee, Roland Y; Huang, Guofu; Porco, Travis C; Chen, Yi-Chun; He, Mingguang; Lin, Shan C
2013-12-01
To evaluate the capability of iris thickness parameters to explain the difference in primary angle-closure glaucoma prevalence among the different racial groups. In this prospective study, 436 patients with open and narrow angles that met inclusion criteria were consecutively recruited from the UCSF general ophthalmology and glaucoma clinics to receive anterior segment optical coherence tomography imaging under standardized dark conditions. Images from 11 patients were removed due to poor visibility of the scleral spurs and the remaining images were analyzed using the Zhongshan Angle Assessment Program to assess the following measurements for the nasal and temporal angle of the anterior chamber: iris thickness at 750 and 2000 μm from the scleral spurs and the maximum iris thickness at middle one third of the iris. Iris thickness parameters were compared among and within the following 5 different racial groups: African Americans, Caucasian Americans, Hispanic Americans, Chinese Americans, and Filipino-Americans. In comparing iris parameters among the open-angle racial groups, significant differences were found for nasal iris thickness at 750 and 2000 μm from the scleral spurs in which Chinese Americans displayed the highest mean value (P=0.01, P<0.0001). Among the narrow-angle racial groups, significant difference was found for nasal iris thickness at 2000 μm from the scleral in which Chinese Americans showed the highest mean value (P<0.0001). Significant difference was also found for temporal maximum iris thickness at middle one third of the iris in which African Americans exhibited the highest mean value (P=0.021). Iris thickness was modeled as a function of angle status using linear mixed-effects regression, adjusting for age, sex, pupil diameter, spherical equivalent, ethnicity, and the use of both eyes in patients. The iris thickness difference between the narrow-angle and open-angle groups was significant (P=0.0007). Racial groups that historically showed higher prevalence of primary angle-closure glaucoma possess thicker irides.
Dastiridou, Anna; Marion, Kenneth; Niemeyer, Moritz; Francis, Brian; Sadda, Srinivas; Chopra, Vikas
2018-04-11
To investigate the effects of ambient light level variation on spectral domain anterior segment optical coherence tomography (SD-ΟCT)-derived anterior chamber angle metrics in Caucasians versus Asians. Caucasian (n = 24) and Asian participants of Chinese ancestry (n = 24) with open angles on gonioscopy had one eye imaged twice at five strictly controlled, ambient light levels. Ethnicity was self-reported. Light levels were strictly controlled using a light meter at 1.0, 0.75, 0.5, 0.25, and 0 foot candle illumination levels. SD-OCT 5-line raster scans at the inferior 270° irido-corneal angle were measured by two trained, masked graders from the Doheny Image Reading Center using customized Image-J software. Schwalbe's line-angle opening distance (SL-AOD) and SL-trabecular iris space area (SL-TISA) in different light meter readings (LMRs) between the two groups were compared. Baseline light SL-AOD and SL-TISA measured 0.464 ± 0.115mm/0.351 ± 0.110mm 2 and 0.344 ± 0.118mm/0.257 ± 0.092mm 2 , respectively, in the Caucasian and the Asian group. SL-AOD and SL-TISA in each LMR were significantly larger in the Caucasian group compared to the Asian group (p < 0.05). Despite this difference in angle size between the groups, there were no statistically significant differences in the degree of change in angle parameters from light to dark (% changes in SL-AOD or SL-TISA between the two groups were statistically similar with all p-values >0.3). SL-based angle dimensions using SD-OCT are sensitive to changes in ambient illumination in participants with Caucasian and Asian ancestry. Although Caucasian eyes had larger baseline angle opening under bright light conditions, the light-to-dark change in angle dimensions was similar in the two groups.
Koh, Victor; Swamidoss, Issac Niwas; Aquino, Maria Cecilia D; Chew, Paul T; Sng, Chelvin
2018-04-27
Develop an algorithm to predict the success of laser peripheral iridotomy (LPI) in primary angle closure suspect (PACS), using pre-treatment anterior segment optical coherence tomography (ASOCT) scans. A total of 116 eyes with PACS underwent LPI and time-domain ASOCT scans (temporal and nasal cuts) were performed before and 1 month after LPI. All the post-treatment scans were classified to one of the following categories: (a) both angles open, (b) one of two angles open and (c) both angles closed. After LPI, success is defined as one or more angles changed from close to open. In this proposed method, the pre and post-LPI ASOCT scans were registered at the corresponding angles based on similarities between the respective local descriptor features and random sample consensus technique was used to identify the largest consensus set of correspondences between the pre and post-LPI ASOCT scans. Subsequently, features such as correlation co-efficient (CC) and structural similarity index (SSIM) were extracted and correlated with the success of LPI. We included 116 eyes and 91 (78.44%) eyes fulfilled the criteria for success after LPI. Using the CC and SSIM index scores from this training set of ASOCT images, our algorithm showed that the success of LPI in eyes with narrow angles can be predicted with 89.7% accuracy, specificity of 95.2% and sensitivity of 36.4% based on pre-LPI ASOCT scans only. Using pre-LPI ASOCT scans, our proposed algorithm showed good accuracy in predicting the success of LPI for PACS eyes. This fully-automated algorithm could aid decision making in offering LPI as a prophylactic treatment for PACS.
Passive rejection of heat from an isotope heat source through an open door
NASA Technical Reports Server (NTRS)
Burns, R. K.
1971-01-01
The isotope heat-source design for a Brayton power system includes a door in the thermal insulation through which the heat can be passively rejected to space when the power system is not operating. The results of an analysis to predict the heat-source surface temperature and the heat-source heat-exchanger temperature during passive heat rejection as a function of insulation door opening angle are presented. They show that for a door opening angle greater than 20 deg, the temperatures are less than the steady-state temperatures during power system operation.
[Basic and clinical studies of pressure-independent damaging factors of open angle glaucoma].
Araie, Makoto
2011-03-01
Pathogenesis of open-angle glaucoma involves both pressure-dependent damaging factors and pressure-independent damaging factors. The high prevalence of open-angle glaucoma with normal pressure (normal-tension glaucoma) in Japan implies that treatment of pressure-independent damaging factors in Japanese open-angle glaucoma patients is of importance. In an attempt to investigate the roles of pressure-independent damaging factors in open-angle glaucoma, we carried out basic and clinical studies and obtained the following results. 1. The rate of deterioration of visual field after trabeculectomy in normal tension glaucoma patients with post-operative intraocular pressure (IOP) of 10 mmHg was found to be -0.25 dB/year of mean deviation (MD), suggesting that contribution of pressure-independent damaging factors to the deterioration of MD in open-angle glaucoma is around -0.25 dB/year of mean deviation (MD). 2. Experiments using isolated purified cultured retinal ganglion cells (RGCs) indicated that calcium-channel blockers and some of antiglaucoma drugs showed neuroprotective effects on RGCs at concentrations of 0.01 microM or higher. 3. In mice, damage to RGCs resulted in secondary degeneration of neurons and activation of glial cells in the lateral geniculate nucleous (LGN) and superior colliculus, and these secondary changes in the central nervous system (CNS) due to RGC damage was partly ameliorated by systemic administration of memantine. 4. Mice experimental high IOP glaucoma models could be established using laser irradiation of the limbal area, and the usefulness of Tonolab in IOP measurements of mice eye was confirmed. 5. Monkey experimental high IOP glaucoma models revealed that in the glaucomatous optic nerve head vaso-constrictive reactions to an alpha-1 agonist was abolished, while vasodilative reaction to a prostaglandin FP receptor agonist was retained. 6. In monkeys with experimental high IOP glaucoma, secondary damage to neurons in the LGN and the glial reaction to it were also found, similar to the mice experiments. In living monkeys the glial reaction in the LGN could be observed by means of positron emission tomography. 7. In the LGN of monkeys with experimental high IOP glaucoma, the M-cell system was preferentially damaged in the early stage, while in the later stages both the M- and P-cell systems were damaged. 8. In a single-instituted prospective double-blinded clinical trial, oral administration of nilvadipine at 4 mg/day, a DHP calcium-channel blocker, was found to significantly retard the visual field progression in normal tension glaucoma patients over 3 years, while significantly increasing the choroidal and optic nerve blood flow by about 35%. 9. A multi-instituted prospective double-blinded clinical trial in normal tension glaucoma patients revealed that the rate of MD deterioration under monotherapy with either topical nipradilol or timolol was around -0.05 dB/year, thought to be considerably slower than -0.25 dB/year, the commonly estimated rate of MD deterioration by pressure-independent damaging factors. The current results indicate the possibility of treatment of pressure-independent damaging factors of open-angle glaucoma in Japanese open-angle glaucoma patients with oral nilvadipine and topical anti-glaucoma agents.
See, Jovina L S; Chew, Paul T K; Smith, Scott D; Nolan, Winifred P; Chan, Yiong‐Huak; Huang, David; Zheng, Ce; Foster, Paul J; Aung, Tin; Friedman, David S
2007-01-01
Aim Using the anterior segment optical coherence tomography (AS‐OCT) to quantify changes in anterior segment morphology going from light to dark and following laser iridotomy (LI). Methods Prospective observational study. 17 consecutive subjects without peripheral anterior synechiae undergoing LI were evaluated using gonioscopy and AS‐OCT. Angle configuration including angle opening distance (AOD) at 500 microns anterior to the scleral spur, AOD500, trabecular‐iris space area up to 750 microns from the scleral spur, TISA750 and the increase in angle opening going from dark to light conditions was determined. Results Both mean AOD500 and TISA750 increased nearly threefold going from dark to light. Both also significantly increased following LI (p<0.001) as did gonioscopic grading of the angle in all quadrants (p<0.001, McNemar's test). Angles were more than twice as wide on average in the dark after LI than before LI (p<0.05). Both the mean absolute change and the mean proportionate change in AOD500 and TISA750 when going from light to dark were greater after LI than before (p<0.05). Conclusion Increased illumination as well as LI resulted in significant widening of the anterior chamber angle. AS‐OCT (which does not require a water bath and can be performed with the patient at the slit lamp) identified similar magnitude changes as those previously reported using ultrasound biomicroscopy (UBM). Furthermore, the angle appears to open more both in absolute terms and and proportionate terms in response to illumination after LI. PMID:17504852
Linkage studies in primary open angle glaucoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avramopoulos, D.; Grigoriadu, M.; Kitsos, G.
1994-09-01
Glaucoma is a leading cause of blindness worldwide. The majority of glaucoma is associated with an open, normal appearing anterior chamber angle and is termed primary open angle glaucoma (POAG, MIM 137760). It is characterized by elevated intraocular pressure and onset in middle age or later. A subset of POAG with juvenile onset has recently been linked to chromosome 1q in two families with autosomal dominant inheritance. Eleven pedigrees with autosomal dominant POG (non-juvenile-onset) have been identified in Epirus, Greece. In the present study DNA samples have been collected from 50 individuals from one large pedigree, including 12 affected individuals.more » Preliminary results of linkage analysis with chromosome 1 microsatellites using the computer program package LINKAGE Version 5.1 showed no linkage with the markers previously linked to juvenile-onset POAG. Further linkage analysis is being pursued, and the results will be presented.« less
Visual Disability Among Juvenile Open-angle Glaucoma Patients.
Gupta, Viney; Ganesan, Vaitheeswaran L; Kumar, Sandip; Chaurasia, Abadh K; Malhotra, Sumit; Gupta, Shikha
2018-04-01
Juvenile onset primary open-angle glaucoma (JOAG) unlike adult onset primary open-angle glaucoma presents with high intraocular pressure and diffuse visual field loss, which if left untreated leads to severe visual disability. The study aimed to evaluate the extent of visual disability among JOAG patients presenting to a tertiary eye care facility. Visual acuity and perimetry records of unrelated JOAG patients presenting to our Glaucoma facility were analyzed. Low vision and blindness was categorized by the WHO criteria and percentage impairment was calculated as per the guidelines provided by the American Medical Association (AMA). Fifty-two (15%) of the 348 JOAG patients were bilaterally blind at presentation and 32 (9%) had low vision according to WHO criteria. Ninety JOAG patients (26%) had a visual impairment of 75% or more. Visual disability at presentation among JOAG patients is high. This entails a huge economic burden, given their young age and associated social responsibilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yang, B; Wong, R; Lam, W
Purpose: To develop a practical method for routine QA of the MLC of a Tomotherapy unit using ArcCheck. Methods: Two standard test plans were used in this study. One was a helical test, in which the central leaves No. 32 and 33 opened simultaneously for 277.8ms at projections centered at 0°, 120° and 240° gantry angles. The other test plan was a static test with the gantry angle set at 0°, 45°, 90° and 135° respectively and leaves No. 32 and 33 opened sequentially for total 20s which was further divided into eleven or ten segments at each beam angle.more » The ArcCheck was isocentrically set up and adjusted for couch sag. Movie files which took a snapshot exposure every 50ms were recorded. The start/stop time of leaf open was decided by the ramp-up/ramp-down of the detectors. Results: The percentage differences between measured and planned leaf open time were calculated to be within 0.5% in all the tests. In static test, if leaves are synchronized perfectly, the sum of the two detectors’ signals after normalization should equal one when the leaves are in transition. Our results showed mean values of 0.982, 0.983, 0.978 and 0.995 at static gantry angle 0°, 45°, 90° and 135° respectively. Conclusion: A method for estimating the Tomotherapy binary MLC leaf open time using ArcCheck is proposed and proved to be precise enough to verify the planned leaf open time as small as 277.8ms. This method also makes the observation and quantification of the synchronization of leaves possible.« less
Experimental assessment of theory for refraction of sound by a shear layer
NASA Technical Reports Server (NTRS)
Schlinker, R. H.; Amiet, R. K.
1978-01-01
The refraction angle and amplitude changes associated with sound transmission through a circular, open-jet shear layer were studied in a 0.91 m diameter open jet acoustic research tunnel. Free stream Mach number was varied from 0.1 to 0.4. Good agreement between refraction angle correction theory and experiment was obtained over the test Mach number, frequency and angle measurement range for all on-axis acoustic source locations. For off-axis source positions, good agreement was obtained at a source-to-shear layer separation distance greater than the jet radius. Measureable differences between theory and experiment occurred at a source-to-shear layer separation distance less than one jet radius. A shear layer turbulence scattering experiment was conducted at 90 deg to the open jet axis for the same free stream Mach numbers and axial source locations used in the refraction study. Significant discrete tone spectrum broadening and tone amplitude changes were observed at open jet Mach numbers above 0.2 and at acoustic source frequencies greater than 5 kHz. More severe turbulence scattering was observed for downstream source locations.
Zero-stress states of human pulmonary arteries and veins.
Huang, W; Yen, R T
1998-09-01
The zero-stress states of the pulmonary arteries and veins from order 3 to order 9 were determined in six normal human lungs within 15 h postmortem. The zero-stress state of each vessel was obtained by cutting the vessel transversely into a series of short rings, then cutting each ring radially, which caused the ring to spring open into a sector. Each sector was characterized by its opening angle. The mean opening angle varied between 92 and 163 degrees in the arterial tree and between 89 and 128 degrees in the venous tree. There was a tendency for opening angles to increase as the sizes of the arteries and veins increased. We computed the residual strains based on the experimental measurements and estimated the residual stresses according to Hooke's law. We found that the inner wall of a vessel at the state in which the internal pressure, external pressure, and longitudinal stress are all zero was under compression and the outer wall was in tension, and that the magnitude of compressive stress was greater than the magnitude of tensile stress.
Does hemipelvis structure and position influence acetabulum orientation?
Musielak, Bartosz; Jóźwiak, Marek; Rychlik, Michał; Chen, Brian Po-Jung; Idzior, Maciej; Grzegorzewski, Andrzej
2016-03-16
Although acetabulum orientation is well established anatomically and radiographically, its relation to the innominate bone has rarely been addressed. If explored, it could open the discussion on patomechanisms of such complex disorders as femoroacetabular impingement (FAI). We therefore evaluated the influence of pelvic bone position and structure on acetabular spatial orientation. We describe this relation and its clinical implications. This retrospective study was based on computed tomography scanning of three-dimensional models of 31 consecutive male pelvises (62 acetabulums). All measurements were based on CT spatial reconstruction with the use of highly specialized software (Rhinoceros). Relations between acetabular orientation (inclination, tilt, anteversion angles) and pelvic structure were evaluated. The following parameters were evaluated to assess the pelvic structure: iliac opening angle, iliac tilt angle, interspinous distance (ISD), intertuberous distance (ITD), height of the pelvis (HP), and the ISD/ITD/HP ratio. The linear and nonlinear dependence of the acetabular angles and hemipelvic measurements were examined with Pearson's product - moment correlation and Spearman's rank correlation coefficient. Correlations different from 0 with p < 0.05 were considered statistically significant. Comparison of the axis position with pelvis structure with orientation in the horizontal plane revealed a significant positive correlation between the acetabular anteversion angle and the iliac opening angle (p = 0.041 and 0.008, respectively). In the frontal plane, there was a positive correlation between the acetabular inclination angle and the iliac tilt angle (p = 0.025 and 0.014, respectively) and the acetabular inclination angle and the ISD/ITD/HP ratio (both p = 0.048). There is a significant correlation of the hemipelvic structure and acetabular orientation under anatomic conditions, especially in the frontal and horizontal planes. In the anteroposterior view, the more tilted-down innominate bone causes a more caudally oriented acetabulum axis, whereas in the horizontal view this relation is reversed. This study may serve as a basis for the discussion on the role of the pelvis in common disorders of the hip.
Nongpiur, Monisha E; Aboobakar, Inas F; Baskaran, Mani; Narayanaswamy, Arun; Sakata, Lisandro M; Wu, Renyi; Atalay, Eray; Friedman, David S; Aung, Tin
2017-03-01
Baseline anterior segment imaging parameters associated with incident gonioscopic angle closure, to our knowledge, are unknown. To identify baseline quantitative anterior segment optical coherence tomography parameters associated with the development of incident gonioscopic angle closure after 4 years among participants with gonioscopically open angles at baseline. Three hundred forty-two participants aged 50 years or older were recruited to participate in this prospective, community-based observational study. Participants underwent gonioscopy and anterior segment optical coherence tomography imaging at baseline and after 4 years. Custom image analysis software was used to quantify anterior chamber parameters from anterior segment optical coherence tomography images. Baseline anterior segment optical coherence tomography measurements among participants with gonioscopically open vs closed angles at follow-up. Of the 342 participants, 187 (55%) were women and 297 (87%) were Chinese. The response rate was 62.4%. Forty-nine participants (14.3%) developed gonioscopic angle closure after 4 years. The mean age (SD) at baseline of the 49 participants was 62.9 (8.0) years, 15 (30.6%) were men, and 43 (87.8%) were Chinese. These participants had a smaller baseline angle opening distance at 750 µm (AOD750) (0.15 mm; 95% CI, 0.12-0.18), trabecular iris surface area at 750 µm (0.07 mm2; 95% CI, 0.05-0.08), anterior chamber area (30 mm2; 95% CI, 2.27-3.74), and anterior chamber volume (24.32 mm2; 95% CI, 18.20-30.44) (all P < .001). Baseline iris curvature (-0.08; 95% CI, -0.12 to -0.04) and lens vault (LV) measurements (-0.29 mm; 95% CI, -0.37 to -0.21) were larger among these participants ( all P < .001). A model consisting of the LV and AOD750 measurements explained 38% of the variance in gonioscopic angle closure occurring at 4 years, with LV accounting for 28% of this variance. For every 0.1 mm increase in LV and 0.1 mm decrease in AOD750, the odds of developing gonioscopic angle closure was 1.29 (95% CI, 1.07-1.57) and 3.27 (95% CI, 1.87-5.69), respectively. In terms of per SD change in LV and AOD750, this translates to an odds ratio of 2.14 (95% CI, 2.48-12.34) and 5.53 (95% CI, 1.22-3.77), respectively. A baseline LV cut-off value of >0.56 mm had 64.6% sensitivity and 84.0% specificity for identifying participants who developed angle closure. These findings suggest that smaller AOD750 and larger LV measurements are associated with the development of incident gonioscopic angle closure after 4 years among participants with gonioscopically open angles at baseline.
Cowan, Lisa A; Khine, Kay T; Chopra, Vikas; Fazio, Doreen T; Francis, Brian A
2015-01-01
To illustrate 3 cases of chronic open-angle glaucoma secondary to the neodymium-yttrium-aluminum-garnet (Nd:YAG) laser vitreolysis procedure for symptomatic vitreous floaters. Observational case series. Location of the study was the Doheny Eye Institute. Three eyes of 2 patients who developed chronic open-angle glaucoma after Nd:YAG vitreolysis for symptomatic floaters presenting with very high intraocular pressure (IOP >40 mm Hg) were selected. The time from the laser treatment to the onset of elevated pressure ranges from 1 week to 8 months. There was no associated inflammation, steroid use, or other identifiable cause of chronic IOP elevation. All eyes were treated initially with glaucoma medication, followed by selective laser trabeculoplasty (SLT) and eventually glaucoma surgery (Trabectome) in 2 eyes for disease management. In all eyes, intraocular pressures were eventually stabilized within a normal pressure range from 18 to 38 months following Nd:YAG vitreolysis. At the latest follow-up post surgery, all eyes had intraocular pressures of 22 mm Hg or less with or without medications. Secondary open-angle glaucoma is a complication of Nd:YAG vitreolysis for symptomatic floaters that may present with an increase in intraocular pressure immediately, or many months after the surgery. Furthermore this complication may be permanent and require chronic medical therapy or glaucoma surgery. Copyright © 2015 Elsevier Inc. All rights reserved.
A target field design of open multi-purpose RF coil for musculoskeletal MR imaging at 3T.
Gao, Fei; Zhang, Rui; Zhou, Diange; Wang, Xiaoying; Huang, Kefu; Zhang, Jue
2016-10-01
Musculoskeletal MR imaging under multi-angle situations plays an increasingly important role in assessing joint and muscle tissues system. However, there are still limitations due to the closed structures of most conventional RF coils. In this study, a time-harmonic target-field method was employed to design open multi-purpose coil (OMC) for multi-angle musculoskeletal MR imaging. The phantom imaging results suggested that the proposed OMC could achieve homogeneously distributed magnetic field and high signal-to-noise ratio (SNR) of 239.04±0.83 in the region of interest (ROI). The maximum temperature in the heating hazard test was 16°C lower than the standard regulation, which indicated the security of the designed OMC. Furthermore, to demonstrate the effectiveness of the proposed OMC for musculoskeletal MR imaging, especially for multi-angle imaging, a healthy volunteer was examined for MR imaging of elbow, ankle and knee using OMC. The in vivo imaging results showed that the proposed OMC is effective for MR imaging of musculoskeletal tissues at different body parts, with satisfied B1 field homogeneity and SNR. Moreover, the open structure of the OMC could provide a large joint movement region. The proposed open multi-purpose coil is feasible for musculoskeletal MR imaging, and potentially, it is more suitable for the evaluation of musculoskeletal tissues under multi-angle conditions. Copyright © 2016. Published by Elsevier Inc.
46 CFR 42.20-12 - Conditions of equilibrium.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., heel, and trim, is below the lower edge of any opening through which progressive flooding can take... angle of heel. The angle of heel due to unsymmetrical flooding does not exceed 15 degrees. If no part of the deck is immersed, an angle of heel of up to 17 degrees may be accepted. (d) Metacentric height...
46 CFR 42.20-12 - Conditions of equilibrium.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., heel, and trim, is below the lower edge of any opening through which progressive flooding can take... angle of heel. The angle of heel due to unsymmetrical flooding does not exceed 15 degrees. If no part of the deck is immersed, an angle of heel of up to 17 degrees may be accepted. (d) Metacentric height...
Perera, Shamira A; Quek, Desmond T; Baskaran, Mani; Tun, Tin A; Kumar, Rajesh S; Friedman, David S; Aung, Tin
2010-06-01
To evaluate EyeCam in detecting changes in angle configuration after laser peripheral iridotomy (LPI) in comparison to gonioscopy, the reference standard. Prospective comparative study. Twenty-four subjects (24 eyes) with primary angle-closure glaucoma (PACG) were recruited. Gonioscopy and EyeCam (Clarity Medical Systems) imaging of all 4 angle quadrants were performed, before and 2 weeks after LPI. Images were graded according to angle structures visible by an observer masked to clinical data or the status of LPI, and were performed in a random order. Angle closure in a quadrant was defined as the inability to visualize the posterior trabecular meshwork. We determined the number of quadrants with closed angles and the mean number of clock hours of angle closure before and after LPI in comparison to gonioscopy. Using EyeCam, all 24 eyes showed at least 1 quadrant of angle widening after LPI. The mean number of clock hours of angle closure decreased significantly, from 8.15 +/- 3.47 clock hours before LPI to 1.75 +/- 2.27 clock hours after LPI (P < .0001, Wilcoxon signed rank test). Overall, gonioscopy showed 1.0 +/- 1.41 (95% CI, 0.43-1.57) quadrants opening from closed to open after LPI compared to 2.0 +/- 1.28 (95% CI, 1.49-2.51, P = .009) quadrants with EyeCam. Intra-observer reproducibility of grading the extent of angle closure in clock hours in EyeCam images was moderate to good (intraclass correlation coefficient 0.831). EyeCam may be used to document changes in angle configuration after LPI in eyes with PACG. Copyright 2010 Elsevier Inc. All rights reserved.
Hirose, Yusuke; Onuki, Mamiko; Tenjimbayashi, Yuri; Mori, Seiichiro; Ishii, Yoshiyuki; Takeuchi, Takamasa; Tasaka, Nobutaka; Satoh, Toyomi; Morisada, Tohru; Iwata, Takashi; Miyamoto, Shingo; Matsumoto, Koji; Sekizawa, Akihiko; Kukimoto, Iwao
2018-06-15
Persistent infection with oncogenic human papillomaviruses (HPVs) causes cervical cancer, accompanied by the accumulation of somatic mutations into the host genome. There are concomitant genetic changes in the HPV genome during viral infection; however, their relevance to cervical carcinogenesis is poorly understood. Here, we explored within-host genetic diversity of HPV by performing deep-sequencing analyses of viral whole-genome sequences in clinical specimens. The whole genomes of HPV types 16, 52, and 58 were amplified by type-specific PCR from total cellular DNA of cervical exfoliated cells collected from patients with cervical intraepithelial neoplasia (CIN) and invasive cervical cancer (ICC) and were deep sequenced. After constructing a reference viral genome sequence for each specimen, nucleotide positions showing changes with >0.5% frequencies compared to the reference sequence were determined for individual samples. In total, 1,052 positions of nucleotide variations were detected in HPV genomes from 151 samples (CIN1, n = 56; CIN2/3, n = 68; ICC, n = 27), with various numbers per sample. Overall, C-to-T and C-to-A substitutions were the dominant changes observed across all histological grades. While C-to-T transitions were predominantly detected in CIN1, their prevalence was decreased in CIN2/3 and fell below that of C-to-A transversions in ICC. Analysis of the trinucleotide context encompassing substituted bases revealed that TpCpN, a preferred target sequence for cellular APOBEC cytosine deaminases, was a primary site for C-to-T substitutions in the HPV genome. These results strongly imply that the APOBEC proteins are drivers of HPV genome mutation, particularly in CIN1 lesions. IMPORTANCE HPVs exhibit surprisingly high levels of genetic diversity, including a large repertoire of minor genomic variants in each viral genotype. Here, by conducting deep-sequencing analyses, we show for the first time a comprehensive snapshot of the within-host genetic diversity of high-risk HPVs during cervical carcinogenesis. Quasispecies harboring minor nucleotide variations in viral whole-genome sequences were extensively observed across different grades of CIN and cervical cancer. Among the within-host variations, C-to-T transitions, a characteristic change mediated by cellular APOBEC cytosine deaminases, were predominantly detected throughout the whole viral genome, most strikingly in low-grade CIN lesions. The results strongly suggest that within-host variations of the HPV genome are primarily generated through the interaction with host cell DNA-editing enzymes and that such within-host variability is an evolutionary source of the genetic diversity of HPVs. Copyright © 2018 American Society for Microbiology.
Dental and skeletal components of Class II open bite treatment with a modified Thurow appliance
Jacob, Helder Baldi; dos Santos-Pinto, Ary; Buschang, Peter H.
2014-01-01
Introduction Due to the lack of studies that distinguish between dentoalveolar and basal changes caused by the Thurow appliance, this clinical study, carried out by the School of Dentistry - State University of São Paulo/Araraquara, aimed at assessing the dental and skeletal changes induced by modified Thurow appliance. Methods The sample included an experimental group comprising 13 subjects aged between 7 and 10 years old, with Class II malocclusion and anterior open bite, and a control group comprising 22 subjects similar in age, sex and mandibular plane angle. Maxillary/mandibular, horizontal/vertical, dental/skeletal movements (ANS, PNS, U1, U6, Co, Go, Pog, L1, L6) were assessed, based on 14 landmarks, 8 angles (S-N-ANS, SNA, PPA, S-N-Pog, SNB, MPA, PP/MPA, ANB) and 3 linear measures (N-Me, ANS-Me, S-Go). Results Treatment caused significantly greater angle decrease between the palatal and the mandibular plane of the experimental group, primarily due to an increase in the palatal plane angle. ANB, SNA and S-N-ANS angles significantly decreased more in patients from the experimental group. PNS was superiorly remodeled. Lower face height (ANS-Me) decreased in the experimental group and increased in the control group. Conclusions The modified Thurow appliance controlled vertical and horizontal displacements of the maxilla, rotated the maxilla and improved open bite malocclusion, decreasing lower facial height. PMID:24713556
Open-ocean fish reveal an omnidirectional solution to camouflage in polarized environments.
Brady, Parrish C; Gilerson, Alexander A; Kattawar, George W; Sullivan, James M; Twardowski, Michael S; Dierssen, Heidi M; Gao, Meng; Travis, Kort; Etheredge, Robert Ian; Tonizzo, Alberto; Ibrahim, Amir; Carrizo, Carlos; Gu, Yalong; Russell, Brandon J; Mislinski, Kathryn; Zhao, Shulei; Cummings, Molly E
2015-11-20
Despite appearing featureless to our eyes, the open ocean is a highly variable environment for polarization-sensitive viewers. Dynamic visual backgrounds coupled with predator encounters from all possible directions make this habitat one of the most challenging for camouflage. We tested open-ocean crypsis in nature by collecting more than 1500 videopolarimetry measurements from live fish from distinct habitats under a variety of viewing conditions. Open-ocean fish species exhibited camouflage that was superior to that of both nearshore fish and mirrorlike surfaces, with significantly higher crypsis at angles associated with predator detection and pursuit. Histological measurements revealed that specific arrangements of reflective guanine platelets in the fish's skin produce angle-dependent polarization modifications for polarocrypsis in the open ocean, suggesting a mechanism for natural selection to shape reflectance properties in this complex environment. Copyright © 2015, American Association for the Advancement of Science.
The Properties of Extragalactic Radio Jets
NASA Astrophysics Data System (ADS)
Finke, Justin
2018-01-01
I show that by assuming a standard Blandford-Konigl jet, it is possible to determine the speed (bulk Lorentz factor) and orientation (angle to the line of sight) of self-similar parsec-scale blazar jets by using four measured quantities: the core radio flux, the extended radio flux, the magnitude of the core shift between two frequencies, and the apparent jet opening angle. Once the bulk Lorentz factor and angle to the line of sight of a jet are known, it is possible to compute their Doppler factor, magnetic field, and intrinsic jet opening angle. I use data taken from the literature and marginalize over nuisance parameters associated with the electron distribution and equipartition, to compute these quantities, albeit with large errors. The results have implications for the resolution of the TeV BL Lac Doppler factor crisis and the production of jets from magnetically arrested disks.
Caça, Ihsan; Simsek, Hüseyin; Unlü, Kaan; Ari, Seyhmus; Keklikçi, Ugur
2006-01-01
We compared latanoprost monotherapy therapy with timolol/ dorzolamide in patients with primary open-angle glaucoma to evaluate the effects on intraocular pressure (IOP) and occurrence of adverse events. IOP and topical side effects were evaluated at the beginning, first, and third months. Mean IOP was decreased at the third month. The most common side effect was hyperemia (43.6%). We concluded that latanoprost reduces IOP better than fixed combination and its topical side effects are tolerable.
Static balance according to hip joint angle of unsupported leg during one-leg standing.
Cha, Ju-Hyung; Kim, Jang-Joon; Ye, Jae-Gwan; Lee, Seul-Ji; Hong, Jeong-Mi; Choi, Hyun-Kyu; Choi, Ho-Suk; Shin, Won-Seob
2017-05-01
[Purpose] This study aimed to determine static balance according to hip joint angle of the unsupported leg during one-leg standing. [Subjects and Methods] Subjects included 45 healthy adult males and females in their 20s. During one-leg standing on the non-dominant leg, the position of the unsupported leg was classified according to hip joint angles of point angle was class. Static balance was then measured using a force plate with eyes open and closed. The total length, sway velocity, maximum deviation, and velocity on the mediolateral and anteroposterior axes of center of pressure were measured. [Results] In balance assessment with eyes open, there were significant differences between groups according to hip joint angle, except for maximum deviation on the anteroposterior axis. In balance assessment with eyes closed, there were significant differences between total length measurements at 0° and 30°, 60° and between 30° and 90°. There were significant differences between sway velocity measurements at 0° and 30° and between 30° and 90°. [Conclusion] Thus, there were differences in static balance according to hip joint angle. It is necessary to clearly identify the hip joint angle during one-leg standing testing.
Comparative assessment of bone pose estimation using Point Cluster Technique and OpenSim.
Lathrop, Rebecca L; Chaudhari, Ajit M W; Siston, Robert A
2011-11-01
Estimating the position of the bones from optical motion capture data is a challenge associated with human movement analysis. Bone pose estimation techniques such as the Point Cluster Technique (PCT) and simulations of movement through software packages such as OpenSim are used to minimize soft tissue artifact and estimate skeletal position; however, using different methods for analysis may produce differing kinematic results which could lead to differences in clinical interpretation such as a misclassification of normal or pathological gait. This study evaluated the differences present in knee joint kinematics as a result of calculating joint angles using various techniques. We calculated knee joint kinematics from experimental gait data using the standard PCT, the least squares approach in OpenSim applied to experimental marker data, and the least squares approach in OpenSim applied to the results of the PCT algorithm. Maximum and resultant RMS differences in knee angles were calculated between all techniques. We observed differences in flexion/extension, varus/valgus, and internal/external rotation angles between all approaches. The largest differences were between the PCT results and all results calculated using OpenSim. The RMS differences averaged nearly 5° for flexion/extension angles with maximum differences exceeding 15°. Average RMS differences were relatively small (< 1.08°) between results calculated within OpenSim, suggesting that the choice of marker weighting is not critical to the results of the least squares inverse kinematics calculations. The largest difference between techniques appeared to be a constant offset between the PCT and all OpenSim results, which may be due to differences in the definition of anatomical reference frames, scaling of musculoskeletal models, and/or placement of virtual markers within OpenSim. Different methods for data analysis can produce largely different kinematic results, which could lead to the misclassification of normal or pathological gait. Improved techniques to allow non-uniform scaling of generic models to more accurately reflect subject-specific bone geometries and anatomical reference frames may reduce differences between bone pose estimation techniques and allow for comparison across gait analysis platforms.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heon, E.; Sheth, B.P.; Kalenak, J.W.
1994-09-01
Genetic factors have been implicated in a variety of types of glaucoma including primary open-angle glaucoma, infantile glaucoma, pigmentary glaucoma, and juvenile open-angle glaucoma. We previously mapped the disease-causing gene for one type of juvenile open angle glaucoma to chromosome 1q21-31. Weatherill and Hart (1969) and Pearce (1983) each noted the association of iris hypoplasia and early-onset autosomal dominant glaucoma. We recently had the opportunity to study a large family (12 affected members) with this phenotype. Affected individuals developed glaucoma at an average age of 30 years. These patients also have a strikingly underdeveloped iris stroma which causes a peculiarmore » eye color. Linkage analysis was able to completely exclude the 1q glaucoma locus from involvement in the disorder that affects this family. A complete clinical description of the family and linkage results at additional candidate loci will be presented.« less
iStent trabecular micro-bypass stent for open-angle glaucoma
Le, Kim; Saheb, Hady
2014-01-01
Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm’s canal. iStents are typically implanted at the time of phacoemulsification for patients with open-angle glaucoma and visually significant cataracts. This review summarizes the published data regarding the efficacy, safety, and cost considerations of trabecular micro-bypass stents. Most studies found statistically significant reductions in mean IOP and ocular medication use after combined phacoemulsification with single or double iStent implantation. The devices were found to be very safe, with a safety profile similar to that of cataract surgery. Complications were infrequent, with the most common complications being temporary stent obstruction or malposition, which resolved with observation or secondary procedures. Future studies are needed to evaluate long-term outcomes, patient satisfaction, cost effectiveness, and expanded indications. PMID:25284980
Sheybani, Arsham; Dick, H Burkhard; Ahmed, Iqbal I K
2016-07-01
To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial of the surgical implantation of the XEN140 implant in patients with open-angle glaucoma. Complete success was defined as a postoperative IOP≤18 mm Hg with ≥20% reduction in IOP at 12 months without any glaucoma medications. Failure was defined as vision loss of light perceptions vision or worse, need for additional glaucoma surgery, or <20% reduction of IOP from baseline. The average age was 64.3 (28.1 to 86.9) years old. Twenty-one eyes had prior failed trabeculectomy with mitomycin C surgery. IOP at 12 months decreased from a mean of 23.1 (±4.1) mm Hg to 14.7 (±3.7) mm Hg for a 36.4% reduction in IOP from baseline. The number of patients at 12 months who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP was 40 (89%). The number of patients who achieved an IOP≤18 mm Hg and ≥20% reduction in IOP without antiglaucoma medications was 18 (40%). The XEN140 gel stent lowers IOP with few complications when implanted for the surgical treatment of open-angle glaucoma.
Murphy, C G; Johnson, M; Alvarado, J A
1992-12-01
We tested the hypothesis that obstruction of the juxtacanalicular tissues, by melanin granules in pigmentary glaucoma and by other impermeable material in primary open angle glaucoma, leads to the development of a chronic glaucomatous condition. The distribution and concentration of melanin and other impermeable materials in the juxtacanalicular tissues and elsewhere in the trabecular meshwork was determined in 13 specimens. Six specimens were from patients with pigmentary glaucoma, two from patients with pigment dispersion syndrome, and three from patients with primary open angle glaucoma, as well as two from normal subjects. The effect of these materials on flow resistance was estimated using two hydrodynamic models. In model A, the electron-lucent spaces of the juxtacanalicular tissue were assumed to be open spaces, while in model B, these spaces and spaces filled with ground substance were assumed to be gel filled. In pigmentary glaucoma, 3.5% of the pigment was found in the juxtacanalicular tissue, while 96.5% was found in the corneoscleral and uveoscleral tissues. Permeabilities calculated according to model A were much higher than those expected from estimates of outflow facility in all groups, in agreement with the previous report of Ethier et al. The gel-filled spaces available for fluid flow, as determined by model B, showed no statistically demonstrable differences (pigmentary glaucoma, 32.9%; primary open angle glaucoma, 36.6%; pigment dispersion syndrome, 43.4%; normal, 44.1%). Furthermore, the amount of pigment present in the juxtacanalicular tissue was determined to have a negligible influence on permeability. Thus, the development of the chronic glaucomatous condition cannot be directly attributed to pigment accumulation in the juxtacanalicular tissue in pigmentary glaucoma.
Sun, Xiang-Yao; Zhang, Xi-Nuo; Hai, Yong
2017-05-01
This study evaluated differences in outcome variables between percutaneous, traditional, and paraspinal posterior open approaches for traumatic thoracolumbar fractures without neurologic deficit. A systematic review of PubMed, Cochrane, and Embase was performed. In this meta-analysis, we conducted online searches of PubMed, Cochrane, Embase using the search terms "thoracolumbar fractures", "lumbar fractures", ''percutaneous'', "minimally invasive", ''open", "traditional", "posterior", "conventional", "pedicle screw", "sextant", and "clinical trial". The analysis was performed on individual patient data from all the studies that met the selection criteria. Clinical outcomes were expressed as risk difference for dichotomous outcomes and mean difference for continuous outcomes with 95 % confidence interval. Heterogeneity was assessed using the χ 2 test and I 2 statistics. There were 4 randomized controlled trials and 14 observational articles included in this analysis. Percutaneous approach was associated with better ODI score, less Cobb angle correction, less Cobb angle correction loss, less postoperative VBA correction, and lower infection rate compared with open approach. Percutaneous approach was also associated with shorter operative duration, longer intraoperative fluoroscopy, less postoperative VAS, and postoperative VBH% in comparison with traditional open approach. No significant difference was found in Cobb angle correction, postoperative VBA, VBA correction loss, Postoperative VBH%, VBH correction loss, and pedicle screw misplacement between percutaneous approach and open approach. There was no significant difference in operative duration, intraoperative fluoroscopy, postoperative VAS, and postoperative VBH% between percutaneous approach and paraspianl approach. The functional and the radiological outcome of percutaneous approach would be better than open approach in the long term. Although trans-muscular spatium approach belonged to open fixation methods, it was strictly defined as less invasive approach, which provided less injury to the paraspinal muscles and better reposition effect.
Glaucoma and clinical characteristics in Vietnamese Americans.
Peng, Pai-Huei; Manivanh, Richard; Nguyen, Ngoc; Weinreb, Robert N; Lin, Shan C
2011-08-01
To assess the proportions of glaucoma types and clinical characteristics in Vietnamese Americans in a single-center, retrospective study. Medical charts of Vietnamese-American patients who visited a single private practice in Northern California from 1998-2007 were reviewed. The main outcome measures included the distribution and characteristics of glaucoma types, and clinical parameters associated with the presence of various glaucomas. Data from 2247 patients aged 18-98 years were reviewed. Glaucoma was determined for 305 patients (13.6%). Among this group, 54.8% had primary open-angle glaucoma (POAG), 26.9% had primary angle-closure glaucoma (PACG), 13.4% had mixed mechanism glaucoma (MMG), and 4.9% had secondary glaucoma. In the MMG group (41 patients), 27 patients who initially had open angles developed narrow angles and underwent laser peripheral iridotomy (LPI) with a mean follow up of 6.4 years from the time of iridotomy. The other 13 patients had glaucoma progression with open angles after LPI. One POAG patient had neovascular glaucoma due to retinal vein occlusion several years later. Compared to the PACG group, the MMG group had significantly lower baseline intraocular pressure (25.0 vs. 20.2 mmHg, p = 0.007) but with no difference in biometry. POAG is the major type of glaucoma in this clinic-based Vietnamese population. However, Vietnamese appear to have a relatively higher proportion of PACG than Caucasians and those of African descent. It is recommended that gonioscopy be part of the regular eye check-up for adult Vietnamese patients.
Edge contact angle and modified Kelvin equation for condensation in open pores.
Malijevský, Alexandr; Parry, Andrew O; Pospíšil, Martin
2017-08-01
We consider capillary condensation transitions occurring in open slits of width L and finite height H immersed in a reservoir of vapor. In this case the pressure at which condensation occurs is closer to saturation compared to that occurring in an infinite slit (H=∞) due to the presence of two menisci that are pinned near the open ends. Using macroscopic arguments, we derive a modified Kelvin equation for the pressure p_{cc}(L;H) at which condensation occurs and show that the two menisci are characterized by an edge contact angle θ_{e} that is always larger than the equilibrium contact angle θ, only equal to it in the limit of macroscopic H. For walls that are completely wet (θ=0) the edge contact angle depends only on the aspect ratio of the capillary and is well described by θ_{e}≈sqrt[πL/2H] for large H. Similar results apply for condensation in cylindrical pores of finite length. We test these predictions against numerical results obtained using a microscopic density-functional model where the presence of an edge contact angle characterizing the shape of the menisci is clearly visible from the density profiles. Below the wetting temperature T_{w} we find very good agreement for slit pores of widths of just a few tens of molecular diameters, while above T_{w} the modified Kelvin equation only becomes accurate for much larger systems.
Nazarova, G A; Konchugova, T V; Iurova, O V; Sichinava, N V; Turova, E A; Rassulova, M A; Morozova, N E
2013-01-01
The objective of the present study was to estimate the effectiveness of the peptide drug cortexin used to treat primary open angle glaucoma. It was shown that endonasal electrophoresis of cortexin resulted in more pronounced positive changes in the dynamics of clinical, functional, perimetric, and electrophysiological characteristics compared with intramuscular administration of the same drug to the patients of the control group. This difference was apparent both immediately after the termination of the treatment and during the long-term follow-up.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yanagawa, T.; Sakagami, H.; Nagatomo, H.
In inertial confinement fusion, the implosion process is important in forming a high-density plasma core. In the case of a fast ignition scheme using a cone-guided target, the fuel target is imploded with a cone inserted. This scheme is advantageous for efficiently heating the imploded fuel core; however, asymmetric implosion is essentially inevitable. Moreover, the effect of cone position and opening angle on implosion also becomes critical. Focusing on these problems, the effect of the asymmetric implosion, the initial position, and the opening angle on the compression rate of the fuel is investigated using a three-dimensional pure hydrodynamic code.
[Thinking about the present primary open angle glaucoma early diagnosis concepts and methods].
Ren, Zeqin
2014-05-01
Early diagnosis of primary open-angle glaucoma has not been clear and consistent in concepts and methods. At present, according to the pathophysiology process of optic nerve damage and its detection technology, early diagnosis on the concept still belongs to the early clinical diagnosis instead of preclinical diagnosis, and on the method depends on the fundus as morphological index combined with the visual field as functional index. The direction of early clinical diagnosis mainly lies in exploring more effective diagnosis index, rather than blindly adopt new diagnostic technology.
Ritch, R; Solomon, L D
1992-01-01
A patient with Weill-Marchesani syndrome and angle-closure glaucoma had persistent appositional closure after laser iridotomy that was unrelieved by topical application of either miotic or cycloplegic agents. Argon laser peripheral iridoplasty successfully opened the angle. The patient's sister also had Weill-Marchesani syndrome and angle closure unrelieved by laser iridotomy. Angle closure in Weill-Marchesani syndrome and the response to laser iridotomy and treatment with either miotic or cycloplegic agents may be complex and depends on the relative proportion of pupillary block as a mechanism underlying the angle closure, the functional status of the zonular apparatus, and the degree of angle crowding by the peripheral iris in the presence or absence of peripheral anterior synechiae.
Equilibrium configurations of the conducting liquid surface in a nonuniform electric field
NASA Astrophysics Data System (ADS)
Zubarev, N. M.; Zubareva, O. V.
2011-01-01
Possible equilibrium configurations of the free surface of a conducting liquid deformed by a nonuniform external electric field are investigated. The liquid rests on an electrode that has the shape of a dihedral angle formed by two intersecting equipotential half-planes (conducting wedge). It is assumed that the problem has plane symmetry: the surface is invariant under shift along the edge of the dihedral angle. A one-parametric family of exact solutions for the shape of the surface is found in which the opening angle of the region above the wedge serves as a parameter. The solutions are valid when the pressure difference between the inside and outside of the liquid is zero. For an arbitrary pressure difference, approximate solutions to the problem are constructed and it is demonstrated the approximation error is small. It is found that, when the potential difference exceeds a certain threshold value, equilibrium solutions are absent. In this case, the region occupied by the liquid disintegrates, the disintegration scenario depending on the opening angle.
Nolan, Winifred P; See, Jovina L; Chew, Paul T K; Friedman, David S; Smith, Scott D; Radhakrishnan, Sunita; Zheng, Ce; Foster, Paul J; Aung, Tin
2007-01-01
To evaluate noncontact anterior segment optical coherence technology (AS-OCT) as a qualitative method of imaging the anterior chamber angle and to determine its ability to detect primary angle closure when compared with gonioscopy in Asian subjects. Prospective observational case series. Two hundred three subjects were recruited from glaucoma clinics in Singapore with diagnoses of primary angle closure, primary open-angle glaucoma, ocular hypertension, or cataract. Both eyes (if eligible) of each patient were included in the study. Exclusion criteria were pseudophakia or previous glaucoma surgery. Images of the nasal, temporal, and inferior angles were obtained with AS-OCT in dark and then light conditions. Gonioscopic angle width was graded using the Spaeth classification for each quadrant in low lighting conditions. Angle closure was defined by AS-OCT as contact between the peripheral iris and angle wall anterior to the scleral spur and by gonioscopy as a Spaeth grade of 0 degree (posterior trabecular meshwork not visible). Comparison of the 2 methods in detecting angle closure was done by eye and by individual. Sensitivities and specificities of AS-OCT were calculated using gonioscopy as the reference standard. Complete data were available for 342 eyes of 200 patients. Of the patients, 70.9% had a clinical diagnosis of treated or untreated primary angle closure. Angle closure in > or =1 quadrants was detected by AS-OCT in 142 (71%) patients (228 [66.7%] eyes) and by gonioscopy in 99 (49.5%) patients (152 [44.4%] eyes). The inferior angle was closed more frequently than the nasal or temporal quadrants using both AS-OCT and gonioscopy. When performed under dark conditions, AS-OCT identified 98% of those subjects found to have angle closure on gonioscopy (95% confidence interval [CI], 92.2-99.6) and led to the characterization of 44.6% of those found to have open angles on gonioscopy to have angle closure as well. With gonioscopy as the reference standard, specificity of AS-OCT in the dark was 55.4% (95% CI, 45.2-65.2) for detecting individuals with angle closure. Anterior segment OCT is a rapid noncontact method of imaging angle structures. It is highly sensitive in detecting angle closure when compared with gonioscopy. More persons are found to have closed angles with AS-OCT than with gonioscopy.
Ocular Pseudoexfoliation and Cardiovascular Disease: A National Cross-Section Comparison Study
French, Dustin D; Margo, Curtis E; Harman, Lynn E
2012-01-01
Background: Pseudoexfoliation is a systemic disorder characterized by the deposition of extracellular matrix material. The microfibrillar material that gives rise to the condition is visible clinically in the anterior segment of the eye, and is also found in other tissues, including blood vessels, skin, gallbladder, kidneys, lungs, and heart. Aims: The present study aims to determine whether ocular pseudoexfoliation is associated with selected cardiovascular diseases. Materials and Methods: A cross-section comparison study was conducted with the help of the Veterans Health Administration databases, using the International Classification of Diseases, Ninth revision, Clinical Modification for pseudoexfoliation of lens capsule and pseudoexfoliation glaucoma. Selected cardiovascular diseases and risk factors for cardiovascular disease were identified using the appropriate medical codes. Patients with primary open-angle glaucoma, chronic sinusitis, and benign prostatic hyperplasia served as the comparison groups. A logistic regression model was used to control for age, gender, race, and major cardiovascular risk factors. Results: There were 6,046 case patients with pseudoexfoliation; approximately half were diagnosed with pseudoexfoliation glaucoma. Various stages of ischemic heart disease, cardiomyopathy, and aortic aneurysm were significantly associated with ocular pseudoexfoliation, after controlling for age, gender, race, and major cardiovascular risk factors. Associations, in general, were less demonstrable relative to the primary open-angle glaucoma comparison group. Conclusion: Associations of ocular pseudoexfoliation with cardiovascular diseases were generally fewer and less pronounced when compared to patients with primary open-angle glaucoma. These results add to the results of earlier studies, which suggest that open-angle glaucoma itself might be a risk factor for certain cardiovascular disorders. PMID:23112968
Comparison between visual field defect in pigmentary glaucoma and primary open-angle glaucoma.
Nilforushan, Naveed; Yadgari, Maryam; Jazayeri, Anisalsadat
2016-10-01
To compare visual field defect patterns between pigmentary glaucoma and primary open-angle glaucoma. Retrospective, comparative study. Patients with diagnosis of primary open-angle glaucoma (POAG) and pigmentary glaucoma (PG) in mild to moderate stages were enrolled in this study. Each of the 52 point locations in total and pattern deviation plot (excluding 2 points adjacent to blind spot) of 24-2 Humphrey visual field as well as six predetermined sectors were compared using SPSS software version 20. Comparisons between 2 groups were performed with the Student t test for continuous variables and the Chi-square test for categorical variables. Thirty-eight eyes of 24 patients with a mean age of 66.26 ± 11 years (range 48-81 years) in the POAG group and 36 eyes of 22 patients with a mean age of 50.52 ± 11 years (range 36-69 years) in the PG group were studied. (P = 0.00). More deviation was detected in points 1, 3, 4, and 32 in total deviation (P = 0.03, P = 0.015, P = 0.018, P = 0.023) and in points 3, 4, and 32 in pattern deviation (P = 0.015, P = 0.049, P = 0.030) in the POAG group, which are the temporal parts of the field. It seems that the temporal area of the visual field in primary open-angle glaucoma is more susceptible to damage in comparison with pigmentary glaucoma.
Holló, Gábor
2017-07-01
To present a case of early primary open-angle glaucoma in which retinal nerve fiber layer thickness (RNFLT), ganglion cell complex (GCC), and visual field progression were accompanied with significant progression of peripapillary angioflow vessel density (PAFD) measured with optical coherence tomographic angiography. A 68-year-old female patient who was under topical intraocular pressure (IOP) lowering medication for 20 years for ocular hypertension of the right and preperimetric primary open-angle glaucoma of the left eye (with reproducible inferotemporal and superotemporal neuroretinal rim and RNFL loss) was prospectively imaged with the AngioVue OCT for RNFLT, GCC thickness, and PAFD, and investigated with the Octopus Normal G2 visual field test on the same days at 6-month intervals for 18 months, while the IOP of the left eye escaped from control. IOP of the left eye fluctuated between 14 and 30 mm Hg in the study period. RNFLT, GCC thickness, and peripapillary PAFD all decreased significantly (linear regression analysis, P=0.030, 0.040, and 0.020, respectively), and a significant 2.1 dB/y progression was seen for a superior visual field cluster. The RNFLT, peripapillary PAFD, and visual field of the right eye remained normal and unchanged. In our case IOP elevation, glaucomatous visual field conversion, and structural progression were accompanied with significant progressive decrease of peripapillary PAFD. The simultaneous thinning of RNFLT and GCC and decrease of peripapillary PAFD suggest that PAFD may potentially be an additional indicator of early progression in primary open-angle glaucoma.
Agarwal, Prakashchand; Sathyan, P; Saini, VK
2014-01-01
ABSTRACT Aim: To compare the difference of retinal macular thickness and macular volume using optical coherence tomography (OCT) in primary open angle glaucoma (POAG) patients with the normal subjects. Materials and methods: This observational case control study included primary open angle glaucoma (POAG) patients (n = 124 eyes) and healthy subjects in the control group (n = 124 eyes). All subjects underwent detailed history, general and systemic exami -nation. Complete ocular examination included best corrected visual acuity (BCVA), slit lamp examination, intraocular pressure (IOP), central corneal thickness, gonioscopy, dilated fundus biomicroscopy. Field analysis was done by white on white Humphrey Field Analyzer (Carl Zeiss). Optical coherence tomography imaging of macular area was performed using Stratus OCT (OCT 3, Version 4, Carl Zeiss Inc, Dublin, California, USA). In both these groups, parameters analyzed were macular thickness, inner macular thicknesses (IMT), outer macular thicknesses (OMT), central macular thick ness (CMT) and total macular volume (TMV). Results: The POAG group had significantly decreased values of TMV, OMT and IMT, compared to control group, while there was no difference in CMT, presumably due to absence of ganglion cells in the central part. Thus, macular thickness and volume parameters may be used for making the diagnosis of glaucoma especially in patients with abnormalities of disc. Conclusion: Macular thickness parameters correlated well with the diagnosis of glaucoma. How to cite this article: Sharma A, Agarwal P, Sathyan P, Saini VK. Macular Thickness Variability in Primary Open Angle Glaucoma Patients using Optical Coherence Tomography. J Current Glau Prac 2014;8(1):10-14. PMID:26997801
Wostyn, Peter; Killer, Hanspeter Esriel; De Deyn, Peter Paul
2017-07-01
The underlying pathophysiology of primary open-angle glaucoma remains unclear, but the lamina cribrosa seems to be the primary site of injury, and raised intraocular pressure is a major risk factor. In recent years, a decreased intracranial pressure, leading to an abnormally high trans-lamina cribrosa pressure difference, has gained interest as a new risk factor for glaucoma. New research now lends support to the hypothesis that a paravascular transport system is present in the eye analogous to the recently discovered 'glymphatic system' in the brain, which is a functional waste clearance pathway that promotes elimination of interstitial solutes, including β-amyloid, from the brain along paravascular channels. Given that β-amyloid has been reported to increase by chronic elevation of intraocular pressure in glaucomatous animal models and to cause retinal ganglion cell death, the discovery of a paravascular clearance system in the eye may provide powerful new insights into the pathophysiology of primary open-angle glaucoma. In this review, we provide a new conceptual framework for understanding the pathogenesis of primary open-angle glaucoma, present supporting preliminary data from our own post-mortem study and hypothesize that the disease may result from restriction of normal glymphatic flow at the level of the lamina cribrosa owing to a low intracranial pressure and/or a high trans-lamina cribrosa pressure gradient. If confirmed, this viewpoint could offer new perspectives for the development of novel diagnostic and therapeutic strategies for this devastating disorder. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
The directivity of the sound radiation from panels and openings.
Davy, John L
2009-06-01
This paper presents a method for calculating the directivity of the radiation of sound from a panel or opening, whose vibration is forced by the incidence of sound from the other side. The directivity of the radiation depends on the angular distribution of the incident sound energy in the room or duct in whose wall or end the panel or opening occurs. The angular distribution of the incident sound energy is predicted using a model which depends on the sound absorption coefficient of the room or duct surfaces. If the sound source is situated in the room or duct, the sound absorption coefficient model is used in conjunction with a model for the directivity of the sound source. For angles of radiation approaching 90 degrees to the normal to the panel or opening, the effect of the diffraction by the panel or opening, or by the finite baffle in which the panel or opening is mounted, is included. A simple empirical model is developed to predict the diffraction of sound into the shadow zone when the angle of radiation is greater than 90 degrees to the normal to the panel or opening. The method is compared with published experimental results.
NASA Technical Reports Server (NTRS)
Dawicke, D. S.; Newman, J. C., Jr.; Sutton, M. A.; Amstutz, B. E.
1994-01-01
Fracture tests were conducted on 2.3mm thick, 305mm wide sheets of 2024-T3 aluminum alloy with from one to five collinear cracks. The cracks were introduced (crack history) into the specimens by three methods: saw cutting, fatigue precracking at a low stress range, and fatigue precracking at a high stress range. For the single crack tests, the initial crack history influenced the stress required for the onset of stable crack growth and the first 10mm of crack growth. The effect on failure stress was about 4 percent or less. For the multiple crack tests, the initial crack history was shown to cause differences of more than 20 percent in the link-up stress and 13 percent in failure stress. An elastic-plastic finite element analysis employing the CTOA fracture criterion was used to predict the fracture behavior of the single and multiple crack tests. The numerical predictions were within 7 percent of the observed link-up and failure stress in all the tests.
NASA Astrophysics Data System (ADS)
Ahmadi, Ali; Seyedi Hosseininia, Ehsan
2017-06-01
This paper discusses the formation of stable arches in granular materials by using a series of laboratory tests. To this aim, a developed trapdoor apparatus is designed to find dimensions of arches formed over the door in cohesionless aggregates. This setup has two new important applications. In order to investigate the maximum width of the opening generated exactly on the verge of failure, the door can be open to an arbitrary size. In addition, the box containing granular materials (or base angle) is able to be set on optional angles from zero to 90 degrees with respect to the horizontal. Therefore, it is possible to understand the effect of different levels of gravity accelerations on the formed arches. It is observed that for all tested granular materials, increasing the door size and decreasing the base angle, both cause to increase the width and height of the arch. Moreover, the shape of all arches is governed by a parabola. Furthermore, the maximum door width is approximately five to 8.6 times the particle size, depending on the internal friction angle of materials and the base angle.
Peterson, Jeffrey R.; Blieden, Lauren S.; Chuang, Alice Z.; Baker, Laura A.; Rigi, Mohammed; Feldman, Robert M.; Bell, Nicholas P.
2016-01-01
Purpose Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Methods Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18–35, 36–45, 46–55, 56–65, and 66–79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Results Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. Conclusion This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states. PMID:26815917
Peterson, Jeffrey R; Blieden, Lauren S; Chuang, Alice Z; Baker, Laura A; Rigi, Mohammed; Feldman, Robert M; Bell, Nicholas P
2016-01-01
Define criteria for iris-related parameters in an adult open angle population as measured with swept source Fourier domain anterior segment optical coherence tomography (ASOCT). Ninety-eight eyes of 98 participants with open angles were included and stratified into 5 age groups (18-35, 36-45, 46-55, 56-65, and 66-79 years). ASOCT scans with 3D mode angle analysis were taken with the CASIA SS-1000 (Tomey Corporation, Nagoya, Japan) and analyzed using the Anterior Chamber Analysis and Interpretation software. Anterior iris surface length (AISL), length of scleral spur landmark (SSL) to pupillary margin (SSL-to-PM), iris contour ratio (ICR = AISL/SSL-to-PM), pupil radius, radius of iris centroid (RICe), and iris volume were measured. Outcome variables were summarized for all eyes and age groups, and mean values among age groups were compared using one-way analysis of variance. Stepwise regression analysis was used to investigate demographic and ocular characteristic factors that affected each iris-related parameter. Mean (±SD) values were 2.24 mm (±0.46), 4.06 mm (±0.27), 3.65 mm (±0.48), 4.16 mm (±0.47), 1.14 (±0.04), 1.51 mm2 (±0.23), and 38.42 μL (±4.91) for pupillary radius, RICe, SSL-to-PM, AISL, ICR, iris cross-sectional area, and iris volume, respectively. Both pupillary radius (P = 0.002) and RICe (P = 0.027) decreased with age, while SSL-to-PM (P = 0.002) and AISL increased with age (P = 0.001). ICR (P = 0.54) and iris volume (P = 0.49) were not affected by age. This study establishes reference values for iris-related parameters in an adult open angle population, which will be useful for future studies examining the role of iris changes in pathologic states.
Graft Angle its Relationship to Tomato Plant Survival
USDA-ARS?s Scientific Manuscript database
Growing plants that can withstand the rigors of open field production is imperative. This study examines the relationship of tensile strength to graft angle and plant survival. Tomato seedlings of ‘FL47’ and ‘Rutgers’ were used as scions on ‘Roma’ rootstock under greenhouse and healing chamber con...
Hydraulic droplet coarsening in open-channel capillaries
NASA Astrophysics Data System (ADS)
Warren, Patrick B.
2016-11-01
Over a range of liquid-solid contact angles, an open-channel capillary with curved or angled sides can show a maximum in the Laplace pressure as a function of the filling state. Examples include double-angle wedges, grooves scored into flat surfaces, steps on surfaces, and the groove between touching parallel cylinders. The liquid in such a channel exhibits a beading instability if the channel is filled beyond the Laplace pressure maximum. The subsequent droplet coarsening takes place by hydraulic transport through the connecting liquid columns that remain in the groove. A mean-field scaling argument predicts the characteristic droplet radius R ˜t1 /7 , as a function of time t . This is confirmed by one-dimensional simulations of the coarsening kinetics. Some remarks are also made on the spreading kinetics of an isolated drop deposited in such a channel.
The Research of the Parallel Computing Development from the Angle of Cloud Computing
NASA Astrophysics Data System (ADS)
Peng, Zhensheng; Gong, Qingge; Duan, Yanyu; Wang, Yun
2017-10-01
Cloud computing is the development of parallel computing, distributed computing and grid computing. The development of cloud computing makes parallel computing come into people’s lives. Firstly, this paper expounds the concept of cloud computing and introduces two several traditional parallel programming model. Secondly, it analyzes and studies the principles, advantages and disadvantages of OpenMP, MPI and Map Reduce respectively. Finally, it takes MPI, OpenMP models compared to Map Reduce from the angle of cloud computing. The results of this paper are intended to provide a reference for the development of parallel computing.
Measurement of surface tension and viscosity by open capillary techniques
Rye,Robert R. , Yost,Frederick G.
1998-01-01
An open-channel capillary is provided, having preferably a v-shaped groove in a flat wettable surface. The groove has timing marks and a source marker in which the specimen to be tested is deposited. The time of passage between the timing marks is recorded, and the ratio of surface tension .gamma. to viscosity .mu. is determined from the equation given below: ##EQU1## where h.sub.0 is the groove depth, .alpha. is the groove angle, .theta. is the liquid/solid contact angle, and t is the flow time. It has been shown by the
The Use of Sun Elevation Angle for Stereogrammetric Boreal Forest Height in Open Canopies
NASA Technical Reports Server (NTRS)
Montesano, Paul M.; Neigh, Christopher; Sun, Guoqing; Duncanson, Laura Innice; Van Den Hoek, Jamon; Ranson, Kenneth Jon
2017-01-01
Stereogrammetry applied to globally available high resolution spaceborne imagery (HRSI; less than 5 m spatial resolution) yields fine-scaled digital surface models (DSMs) of elevation. These DSMs may represent elevations that range from the ground to the vegetation canopy surface, are produced from stereoscopic image pairs (stereo pairs) that have a variety of acquisition characteristics, and have been coupled with lidar data of forest structure and ground surface elevation to examine forest height. This work explores surface elevations from HRSI DSMs derived from two types of acquisitions in open canopy forests. We (1) apply an automated mass-production stereogrammetry workflow to along-track HRSI stereo pairs, (2) identify multiple spatially coincident DSMs whose stereo pairs were acquired under different solar geometry, (3) vertically co-register these DSMs using coincident spaceborne lidar footprints (from ICESat-GLAS) as reference, and(4) examine differences in surface elevations between the reference lidar and the co-registered HRSI DSMs associated with two general types of acquisitions (DSM types) from different sun elevation angles. We find that these DSM types, distinguished by sun elevation angle at the time of stereo pair acquisition, are associated with different surface elevations estimated from automated stereogrammetry in open canopy forests. For DSM values with corresponding reference ground surface elevation from spaceborne lidar footprints in open canopy northern Siberian Larix forests with slopes less than10, our results show that HRSI DSM acquired with sun elevation angles greater than 35deg and less than 25deg (during snow-free conditions) produced characteristic and consistently distinct distributions of elevation differences from reference lidar. The former include DSMs of near-ground surfaces with root mean square errors less than 0.68 m relative to lidar. The latter, particularly those with angles less than 10deg, show distributions with larger differences from lidar that are associated with open canopy forests whose vegetation surface elevations are captured. Terrain aspect did not have a strong effect on the distribution of vegetation surfaces. Using the two DSM types together, the distribution of DSM-differenced heights in forests (6.0 m, sigma = 1.4 m) was consistent with the distribution of plot-level mean tree heights (6.5m, sigma = 1.2 m). We conclude that the variation in sun elevation angle at time of stereo pair acquisition can create illumination conditions conducive for capturing elevations of surfaces either near the ground or associated with vegetation canopy. Knowledge of HRSI acquisition solar geometry and snow cover can be used to understand and combine stereogrammetric surface elevation estimates to co-register rand difference overlapping DSMs, providing a means to map forest height at fine scales, resolving the vertical structure of groups of trees from spaceborne platforms in open canopy forests.
Influence of Contact Angle, Growth Angle and Melt Surface Tension on Detached Solidification of InSb
NASA Technical Reports Server (NTRS)
Wang, Yazhen; Regel, Liya L.; Wilcox, William R.
2000-01-01
We extended the previous analysis of detached solidification of InSb based on the moving meniscus model. We found that for steady detached solidification to occur in a sealed ampoule in zero gravity, it is necessary for the growth angle to exceed a critical value, the contact angle for the melt on the ampoule wall to exceed a critical value, and the melt-gas surface tension to be below a critical value. These critical values would depend on the material properties and the growth parameters. For the conditions examined here, the sum of the growth angle and the contact angle must exceed approximately 130, which is significantly less than required if both ends of the ampoule are open.
Ocular surface disease incidence in patients with open-angle glaucoma.
Radenković, Marija; Stanković-Babić, Gordana; Jovanović, Predrag; Djordjević-Jocić, Jasmina; Trenkić-Božinović, Marija
2016-01-01
Ocular surface disease (OSD) is a multifactorial disease of the tears and ocular surface that results in symptoms of discomfort, visual disturbances, tear film instability with potential damage to the ocular surface, accompanied by increased tear film osmolarity and inflammation of the ocular surface. It is a consequence of disrupted homeostasis of lacrimal functional unit. The main pathogenetic mechanism stems from tear hyperosmolarity and tear film instability. The etiological classification is hyposecretory (Sy-Sjögren and non-Sjögren) and evaporative (extrinsic and intrinsic) form. Delphi panel classification grades disease stages. Antiglaucoma topical therapy causes exacerbation or occurrence of symptoms of dry eye due to main ingredients or preservatives (benzalkonium chloride – BAK), which are dose- and time-dependent. BAK reduces the stability of the lipid layer of tears, the number of goblet cells, induces apoptosis and inflammatory infiltration. The aim of this study was the analysis of the OSD incidence in open-angle glaucoma patients caused by topical medicamentous therapy. Retrospective analysis of examined patients with open-angle glaucoma was used. Increased incidence of moderate and advanced OSD Index degrees in the group of primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma. According to the Delphi Panel Scale the most common grade is IIb (POAG and pseudoexfoliative glaucoma). Evaporative form of OSD prevailed in all treatment groups. High percentage of dry eye in patients with higher concentrations of preservatives applied was noticed. OSD should be timely diagnosed and treated. Dry eye has an impact on surgical outcome and postoperative visual acuity, and in order to improve patient compliance and quality of life, symptoms of dry eye should be addressed and medications with lower concentrations of preservatives should be applied.
Kwun, Jun-Dae; Kim, Hee-June; Park, Jaeyoung; Park, Il-Hyung; Kyung, Hee-Soo
2017-01-01
The purpose of this study was to evaluate the usefulness of three-dimensional (3D) printed models for open wedge high tibial osteotomy (HTO) in porcine bone. Computed tomography (CT) images were obtained from 10 porcine knees and 3D imaging was planned using the 3D-Slicer program. The osteotomy line was drawn from the three centimeters below the medial tibial plateau to the proximal end of the fibular head. Then the osteotomy gap was opened until the mechanical axis line was 62.5% from the medial border along the width of the tibial plateau, maintaining the posterior tibial slope angle. The wedge-shaped 3D-printed model was designed with the measured angle and osteotomy section and was produced by the 3D printer. The open wedge HTO surgery was reproduced in porcine bone using the 3D-printed model and the osteotomy site was fixed with a plate. Accuracy of osteotomy and posterior tibial slope was evaluated after the osteotomy. The mean mechanical axis line on the tibial plateau was 61.8±1.5% from the medial tibia. There was no statistically significant difference (P=0.160). The planned and post-osteotomy correction wedge angles were 11.5±3.2° and 11.4±3.3°, and the posterior tibial slope angle was 11.2±2.2° pre-osteotomy and 11.4±2.5° post-osteotomy. There were no significant differences (P=0.854 and P=0.429, respectively). This study showed that good results could be obtained in high tibial osteotomy by using 3D printed models of porcine legs. Copyright © 2016 Elsevier B.V. All rights reserved.
Marjanović, Ivan; Martinez, Antonio; Marjanović, Marija; Kontić, Djordje; Hentova-Senćanić, Paraskeva; Marković, Vujica; Bozić, Marija
2013-01-01
An altered perfusion of the optic nerve head has been proposed as a pathogenic factor of glaucoma. The aim of this study was to evaluate the changes of the hemodynamic parameters in the retrobulbar arterial circulation after decrease of the elevated intraocular pressure (IOP) in women and men with primary open angle glaucoma. The study included 60 patients (33 males and 27 females) older than 50 years, with diagnosed and treated primary open angle glaucoma (77 eyes of 39 patients had increased IOP, > 25 mm Hg).They were examined at the Clinic of Eye Diseases (complete ophthalmologic exam) and Clinic of Neurology, Clinical Center of Serbia, Belgrade, from December 2009 to December 2010. Imaging of hemodynamic parameters of three retrobulbar arterial vessels: ophthalmic, central retinal and posterior ciliary arteries with color Doppler was performed. Among women, hemodynamic arterial parameter of the peak-systolic velocity was increased in the central retinal artery and decreased in the ophthalmic artery and posterior ciliary arteries; end-diastolic velocity was increased in all three retrobulbar vascular levels; Pourcelot resistivity index was increased, but pulsatility index was decreased in all three vessels. Among men, peak-systolic velocity, end-diastolic velocity and pulsatility index were decreased in all three vessels; resistivity index was increased in the ophthalmic artery, but decreased in the central retinal artery and posterior ciliary arteries. There was a significant change of the ophthalmic artery pulsatility index in women, and the end-diastolic velocity of the ophthalmic artery in men. There was a difference of the retrobulbar arterial circulation between women and men with primary open angle glaucoma after decrease of the elevated intraocular pressure.The role of vascular factors in the supply of the optic disc neuroretinal rim is important.
Hip arthroscopy versus open surgical dislocation for femoroacetabular impingement
Zhang, Dagang; Chen, Long; Wang, Guanglin
2016-01-01
Abstract Background: This meta-analysis aims to evaluate the efficacy and safety of hip arthroscopy versus open surgical dislocation for treating femoroacetabular impingement (FAI) through published clinical trials. Methods: We conducted a comprehensive literature search using PUBMED, EMBASE, and the Cochrane Central Register of Controlled Trials databases for relevant studies on hip arthroscopy and open surgical dislocation as treatment options for FAI. Results: Compared with open surgical dislocation, hip arthroscopy resulted in significantly higher Nonarthritic Hip Scores (NAHS) at 3- and 12-month follow-ups, a significant improvement in NAHS from preoperation to 3 months postoperation, and a significantly lower reoperation rate. Open surgical dislocation resulted in a significantly improved alpha angle by the Dunn view in patients with cam osteoplasty from preoperation to postoperation, compared with hip arthroscopy. This meta-analysis demonstrated no significant differences in the modified Harris Hip Score, Hip Outcome Score-Activities of Daily Living, or Hip Outcome Score-Sport Specific Subscale at 12 months of follow-up, or in complications (including nerve damage, wound infection, and wound dehiscence). Conclusion: Hip arthroscopy resulted in higher NAHS and lower reoperation rates, but had less improvement in alpha angle in patients with cam osteoplasty, than open surgical dislocation. PMID:27741133
The Opening of the Arctic: Establishing a New Security Perimeter for the United States
2013-02-14
Eastern oil is projected to come to an end by 2032. British Petroleum, in its annual energy outlook, predicts growth in biofuel supplies and...Inclination angles for GPS and Galileo satellites are 55 and 56 degrees respectively while GLONASS inclination angles are marginally better at 65
Miniaturized haploscope for testing binocular vision
NASA Technical Reports Server (NTRS)
Decker, T. A.
1973-01-01
Device can reproduce virtually all binocular stimulus conditions (target configuration, vergence angle, and accommodative distance) used to test binocular performance. All subsystems of electronic controls are open-loop and solid-state-controlled and, with the exception of vergence angle drive, utilize dc stepping motors as prime movers. Arrangement is also made for readouts of each variable.
Klatt, K; Schmidt, E; Scheuerle, A F
2008-04-01
The Ocular Hypertension Treatment Study (OHTS) has shown that analyzing changes of the optic disc configuration is superior to evaluating visual field findings for the early detection of primary open angle glaucoma. The Confocal Scanning Laser Ophthalmoscopy Ancillary Study (CSLO) is the first study to reveal that certain topographic baseline measurements of the optic disc are significantly associated with the development of primary open angle glaucoma in patients with ocular hypertension. An abnormally increased "mean height contour" value proved to be the individual parameter connected with the highest risk. The reliability of the Moorfields Regression Analysis of certain individual sectors during early detection of a primary angle glaucoma is higher than that of the global measurement. The temporal superior and inferior as well as the nasal inferior sectors have the highest positive predictive values and the largest risks in both univariate and multivariate analysis.
Brief, Gerrett; Lammich, Tobias; Nagel, Edgar; Pfennigsdorf, Sabine; Spraul, Christoph W; Ho, Selwyn
2010-01-01
Objective To assess the efficacy and tolerability of a fixed combination of bimatoprost and timolol (BTFC) in a large patient sample in a clinical setting. Methods In this multicenter, observational, noncontrolled, open-label study, patients (n = 1862) with primary open-angle glaucoma or ocular hypertension were treated with BTFC. Assessments were made at baseline, six weeks, and three months. Results Prior to starting BTFC, 92.3% of patients were taking other ocular hypotensive medications. In the overall group at three months, mean intraocular pressure was reduced from baseline (21.7 ± 4.5 mmHg and 21.8 ± 4.9 mmHg for the right and left eye, respectively) to 16.1 ± 3.0 mmHg for each eye (P < 0.0001). The majority of patients (92%) reported no adverse events. The most commonly reported adverse events (in >1% of patients) were eye irritation, and ocular and conjunctival hyperemia. Adherence to treatment was generally better than (35.4%) or the same as (57.5%) with prior therapy. BTFC tolerability was rated as excellent or good by 92.3% of physicians and 85.8% of patients. Conclusions In a large group of patients with primary open-angle glaucoma or ocular hypertension, treatment with BTFC was associated with consistent reductions in IOP, improved adherence to treatment, and good tolerability. PMID:20957059
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geltman, S.
Recent measurements on CO{sub 2}-laser-assisted electron-atom collisions have shown large inconsistencies with the Kroll-Watson formula for small-angle scattering. We have carried out a detailed study to compare the predictions of Kroll-Watson theory (for both single and multimode fields) with those of conventional perturbation theory for stimulated free-free transitions. It is found that for {ital E}{sub 0}/2{omega}{sup 2}{lt}1, where perturbation theory is valid, there are large differences with the Kroll-Watson theory. Comparisons of experimental variations with respect to scattering angle and electron energy show much better agreement with perturbation theory than with Kroll-Watson theory. A study of the angular variations inmore » perturbation theory shows that use of the {open_quote}{open_quote}outgoing{close_quote}{close_quote} wave final state gives much better agreement with experiment than does the {open_quote}{open_quote}ingoing{close_quote}{close_quote} wave final state, which is different from the choice made in early bremsstrahlung theory. {copyright} {ital 1996 The American Physical Society.}« less
Anterior chamber angle assessment using gonioscopy and ultrasound biomicroscopy.
Narayanaswamy, Arun; Vijaya, Lingam; Shantha, B; Baskaran, Mani; Sathidevi, A V; Baluswamy, Sukumar
2004-01-01
Comparison of anterior chamber angle measurements using ultrasound biomicroscopy (UBM) and gonioscopy. Five hundred subjects were evaluated for grading of angle width by the Shaffer method. UBM was done in the same group to document angle width, angle opening distance (AOD 500), and anterior chamber depth. Biometric parameters were documented in all subjects. UBM and gonioscopic findings were compared. A study was conducted in 282 men and 218 women with a mean age of 57.32 +/- 12.48 years. Gonioscopic grading was used to segregate occludable (slit-like, grades 1 and 2) from nonoccludable (grades 3 and 4) angles. Subjective assessment by gonioscopy resulted in an overestimation of angle width within the occludable group when compared with values obtained by UBM. This did not affect the segregation of occludable versus nonoccludable angles by gonioscopy. Biometric parameters in eyes with occludable angles were significantly lower in comparison with eyes with nonoccludable angles, except for lens thickness. AOD 500 correlated well with angle width. We concluded that clinical segregation into occludable and nonoccludable angles by an experienced observer using gonioscopy is fairly accurate. However, UBM is required for objective quantification of angles, and AOD 500 can be a reliable and standard parameter to grade angle width.
Franzotti Sant'Anna, Eduardo; Carneiro da Cunha, Amanda; Paludo Brunetto, Daniel; Franzotti Sant'Anna, Claudia
2017-03-01
The treatment of skeletal anterior open-bite malocclusion requires complex orthodontic planning that considers its multifactorial etiology, treatment limitations, and high relapse rates. This case report illustrates a successful treatment approach for a skeletal high-angle Class II malocclusion in an adult with a severe open bite. The treatment consisted of a high-pull headgear therapy after mini-implants failure during fixed orthodontic therapy. Adequate esthetics and function were achieved. Despite its low probability, the unexpected event of mini-implant loosening during complex treatments should be considered. Therefore, classic orthodontic mechanics should be established, especially when treating patients for whom invasive procedures such as miniplates or orthognathic surgery are not available options. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Dwyer Cianciolo, Alicia; Powell, Richard W.
2017-01-01
Precision landing on Mars is a challenge. All Mars lander missions prior to the 2012 Mars Science Laboratory (MSL) had landing location uncertainty ellipses on the order of hundreds of kilometers. Sending humans to the surface of Mars will likely require multiple landers delivered in close proximity, which will in turn require orders of magnitude improvement in landing accuracy. MSL was the first Mars mission to use an Apollo-derived bank angle guidance to reduce the size of the landing ellipse. It utilized commanded bank angle magnitude to control total range and bank angle reversals to control cross range. A shortcoming of this bank angle guidance is that the open loop phase of flight created by use of bank reversals increases targeting errors. This paper presents a comparison of entry, descent and landing performance for a vehicle with a low lift-to-drag ratio using both bank angle control and an alternative guidance called Direct Force Control (DFC). DFC eliminates the open loop flight errors by directly controlling two forces independently, lift and side force. This permits independent control of down range and cross range. Performance results, evaluated using the Program to Optimize Simulated Trajectories (POST2), including propellant use and landing accuracy, are presented.
Reflectance Spectra of Peacock Feathers and the Turning Angles of Melanin Rods in Barbules.
Okazaki, Toshio
2018-02-01
I analyzed the association between the reflectance spectra and melanin rod arrangement in barbules of the eyespot of peacock feathers. The reflectance spectra from the yellow-green feather of the eyespot indicated double peaks of 430 and 540 nm. The maximum reflectance spectrum of the blue feather was 480 nm, and that of the dark blue feather was 420 nm. The reflectance spectra from brown feathers indicated double peaks of 490 and 610 nm. Transmission electron microscopic analysis confirmed that melanin rods were arranged fanwise in the outer layer toward the barbule tips. In addition, using polarized light microscope, I attempted to determine whether the turning angles of melanin rods in the barbules reflected different colors. The turning angle of the polarizing axis of the barbules was supported by that of the melanin rods, observed using transmission electron microscopic images. To compare the turning angle of melanin rods in the respective barbules, I calculated the opening width of the fanwise melanin rods by dividing the width of the barbules by the turning angle of the polarizing axis of barbules and obtained a positive correlation between the reflectance spectra and opening width of the fanwise melanin rods. Moreover, the widely spreading reflection from the barbules may occur because of the fanwise melanin rod arrangement.
Agreement between gonioscopy and ultrasound biomicroscopy in detecting iridotrabecular apposition.
Barkana, Yaniv; Dorairaj, Syril K; Gerber, Yariv; Liebmann, Jeffrey M; Ritch, Robert
2007-10-01
To assess the agreement between findings obtained at dark-room gonioscopy and ultrasound biomicroscopy (UBM) in the diagnosis of iridotrabecular apposition in light and dark conditions. We enrolled patients with appositional angle closure at dark-room gonioscopy performed using a 1-mm slitlamp beam that did not cross the pupil. Ultrasound biomicroscopic images were acquired in normal room light and subsequently with all room lights off. Images were evaluated for the presence or absence of iris-cornea contact. The angle opening distance at 500 microm was calculated. Iridotrabecular apposition in at least 1 angle quadrant was demonstrated in all 18 eyes at dark-room gonioscopy, 17 eyes (94%) at dark-room UBM, and only 10 eyes (56%) at UBM in room light. Of 18 superior angles that were appositionally closed at dark-room gonioscopy, apposition was demonstrated on UBM images in 16 (89%) in a dark room but only 6 (33%) in room light. Angle opening distance was less during dark-room gonioscopy in all but the nasal quadrant. We found high agreement between gonioscopy and UBM when both are performed in a completely dark room. Our findings support the recommendation that, in routine clinical practice, gonioscopy be performed in a dark room to avoid misdiagnosis of treatable iridotrabecular apposition.
Zhao, Jing-Xin; Su, Xiu-Yun; Xiao, Ruo-Xiu; Zhao, Zhe; Zhang, Li-Hai; Zhang, Li-Cheng; Tang, Pei-Fu
2016-11-01
We established a mathematical method to precisely calculate the radiographic anteversion (RA) and radiographic inclination (RI) angles of the acetabular cup based on anterior-posterior (AP) pelvic radiographs after total hip arthroplasty. Using Mathematica software, a mathematical model for an oblique cone was established to simulate how AP pelvic radiographs are obtained and to address the relationship between the two-dimensional and three-dimensional geometry of the opening circle of the cup. In this model, the vertex was the X-ray beam source, and the generatrix was the ellipse in radiographs projected from the opening circle of the acetabular cup. Using this model, we established a series of mathematical formulas to reveal the differences between the true RA and RI cup angles and the measurements results achieved using traditional methods and AP pelvic radiographs and to precisely calculate the RA and RI cup angles based on post-operative AP pelvic radiographs. Statistical analysis indicated that traditional methods should be used with caution if traditional measurements methods are used to calculate the RA and RI cup angles with AP pelvic radiograph. The entire calculation process could be performed by an orthopedic surgeon with mathematical knowledge of basic matrix and vector equations. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Handling Qualities of a Capsule Spacecraft During Atmospheric Entry
NASA Technical Reports Server (NTRS)
Bilimoria, Karl D.; Mueller, Eric R.
2010-01-01
A piloted simulation was conducted to study handling qualities for capsule spacecraft entering the Earth s atmosphere. Eight evaluation pilots, including six pilot astronauts, provided Cooper-Harper ratings, workload ratings, and qualitative comments. The simulation began after descending through the atmospheric entry interface point and continued until the drogue parachutes deployed. There were two categories of piloting tasks, both of which required bank angle control. In one task category, the pilot followed a closed-loop bank angle command computed by the backup guidance system to manage g-loads during entry. In the other task category, the pilot used intuitive rules to determine the desired bank angle independently, based on an open-loop schedule of vertical speed, Mach, and total energy specified at several range-to-target gates along the entry trajectory. Pilots were able to accurately track the bank angle guidance commands and steered the capsule toward the recovery site with essentially the same range error as the benchmark autopilot trajectory albeit with substantially higher propellant usage, and the handling qualities for this task were satisfactory. Another key result was that the complex piloting task of atmospheric entry could be performed satisfactorily, even in the presence of large dispersions, by controlling bank angle to follow a simple open-loop schedule.
NASA Technical Reports Server (NTRS)
Cuzzi, Jeffrey N.; French, Richard G.; Dones, Luke; DeVincenzi, Donald (Technical Monitor)
2001-01-01
The main rings of Saturn were observed with the Planetary Camera of the WFPC2 instrument on the Hubble Space Telescope (HST) from September 1996 to August 2000 as the'ring opening angle to Earth and Sun increased from 4 deg to 24 deg, with a spread of phase angles between 0.3 deg and 6 deg at each opening angle. The rings were routinely observed in the five HST wideband UBVRI filters (F336W, F439W, F555W, F675W, and F814W) and occasionally in the F255W, F785LP, and F1042M filters. The emphasis in this series of papers will be on radial color (implying compositional) variations. In this first paper we describe the analysis technique and calibration procedure, note revisions in a previously published Voyager ring color data analysis, and present new results based on over 100 HST images. In the 300-600 nm spectral range where the rings are red, the 555nm/336nm ratio increases by about 14% as the phase angle increases from 0.3 deg to 6 deg. This effect, never reported previously for the rings, is significantly larger than the phase reddening which characterizes other icy objects, primarily because of the redness of the rings. However, there is no discernible tendency for color to vary with ring opening angle at a given phase angle, and there is no phase variation of color where the spectrum is flat. We infer from this combination of facts that multiple intraparticle scattering, either in a regolith or between facets of an unusually rough surface, is important in these geometries, but that multiple interparticle scattering in a vertically extended layer is not. Voyager color ratios at a phase angle of 14 deg are compatible with this trend, but calibration uncertainties prevent their use in quantitative modeling. Overall ring-average spectra are compatible with those of earlier work within calibration uncertainties, but ring spectra vary noticeably with region. We refine and subdivide the regions previously defined by others. The variation seen between radial profiles of ratios between different wavelength suggests the presence of multiple compositional components with different radial distributions. We present new radial profiles of far UV color ratio (F336W/F255W) showing, substantial global variations having a different radial structure than seen between 555 and 336nm. We also find evidence for absorption in the 850nm spectral range (a feature previously only weakly indicated in ring-averaged spectra) primarily through its radial variation; it is located primarily in the C ring, where the particles are known to have lower albedo, and is consistent with "interplanetary pollution" of the rings.
Brightness discrimination test is not useful in screening for open angle glaucoma.
Peter, E; Thomas, R; Muliyil, J
1996-06-01
Brightness discrimination test (BDT) is routinely employed to assess asymmetrical optic nerve dysfunction and has been suggested as a screening test for primary open angle glaucoma (POAG). We tested the reliability and validity of BDT in the diagnosis of POAG. The study groups included 34 patients with established primary open angle glaucoma, 20 glaucoma suspects, and 33 age-sex matched controls. Cataract was not an exclusion criterion in these groups. The normal brightness score was determined to be 88% (mean score, 94%-2 SD) in a pilot study. Brightness discrimination test was performed in all subjects by two observers independently. BDT showed an excellent interobserver agreement (weighted Kappa 0.84). The presence of a cataract alone increased the risk of brightness impairment twofold, glaucoma alone increased the risk eightfold, and the presence of both conditions by 17 times compared to those with neither condition. BDT was not a useful test in the diagnosis of POAG (sensitivity 67% and specificity 93%); the ability to detect a significant field defect was also poor (sensitivity 53% and specificity 76%). There was poor association between decreased brightness scores and asymmetrical field defects as determined by the Humphrey's field analyzer (HFA).
Characterizing the “POAGome”: A bioinformatics-driven approach to primary open-angle glaucoma
Danford, Ian D.; Verkuil, Lana D.; Choi, Daniel J.; Collins, David W.; Gudiseva, Harini V.; Uyhazi, Katherine E.; Lau, Marisa K.; Kanu, Levi N.; Grant, Gregory R.; Chavali, Venkata R.M.; O’Brien, Joan M.
2017-01-01
Primary open-angle glaucoma (POAG) is a genetically, physiologically, and phenotypically complex neurodegenerative disorder. This study addressed the expanding collection of genes associated with POAG, referred to as the “POAGome.” We used bioinformatics tools to perform an extensive, systematic literature search and compiled 542 genes with confirmed associations with POAG and its related phenotypes (normal tension glaucoma, ocular hypertension, juvenile open-angle glaucoma, and primary congenital glaucoma). The genes were classified according to their associated ocular tissues and phenotypes, and functional annotation and pathway analyses were subsequently performed. Our study reveals that no single molecular pathway can encompass the pathophysiology of POAG. The analyses suggested that inflammation and senescence may play pivotal roles in both the development and perpetuation of the retinal ganglion cell degeneration seen in POAG. The TGF-β signaling pathway was repeatedly implicated in our analyses, suggesting that it may be an important contributor to the manifestation of POAG in the anterior and posterior segments of the globe. We propose a molecular model of POAG revolving around TGF-β signaling, which incorporates the roles of inflammation and senescence in this disease. Finally, we highlight emerging molecular therapies that show promise for treating POAG. PMID:28223208
Oxidative stress markers in patients with primary open-angle glaucoma.
Ghanem, Asaad A; Arafa, Lamiaa F; El-Baz, Ayman
2010-04-01
To investigate the levels of antioxidant enzymes catalase (CAT), glutathione peroxidase (GPO), superoxide dismutase (SOD), and malondialdehyde (MDA) in human eyes with primary open-angle glaucoma (POAG) and to correlate their concentrations with severity of glaucoma. A prospective cases control study. Thirty patients with primary open-angle glaucoma and twenty-five patients with senile cataracts of matched age and gender were included in the study prospectively. Aqueous humor samples were obtained by paracentesis at the time of elective surgery for glaucomatous and cataractous patients. Aqueous humor were analyzed for CAT, GPO, SOD, and MDA status. GPO, SOD, and MDA enzyme levels revealed a high significant increase in aqueous humor of POAG patients with respect to the comparative group of cataract patients (P < 0.001). No significant difference in the activity of CAT enzyme in aqueous humor of POAG and cataract patient (P = 0.201). Significant correlation was found between the MDA enzyme level and severe visual field loss (P < 0.001) in POAG patients. Increased levels of aqueous humor GPO, SOD, and MDA may be associated with POAG. In addition, they may be useful antioxidant enzyme levels in aqueous humor of POAG patients as a result of glaucoma disease and not a cause.
Tamçelik, Nevbahar; Izgi, Belgin; Temel, Ahmet; Yildirim, Nilgun; Okka, Mehmet; Özcan, Altan; Yüksel, Nurşen; Elgin, Ufuk; Altan, Çiğdem; Ozer, Baris
2017-01-01
Objective The objective of this study was to assess the intraocular pressure (IOP)-lowering efficacy, tolerability, safety, and usage patterns of prostaglandin analog/prostamide (PGA/P)-containing topical ocular hypotensives in ocular hypertension (OHT) and primary open-angle glaucoma in the Turkish clinical setting. Methods This non-interventional, multicenter study enrolled previously treated patients who failed to achieve target IOP (or experienced unacceptable adverse events [AEs]) and were prescribed a PGA/P-containing IOP-lowering agent. Treatment was initiated at baseline (V1), and patients returned at weeks 4–6 (V2) and 8–12 (V3). The primary efficacy measure was the change in IOP from baseline at V3 in each eye. The secondary measures were physician’s assessment of IOP-lowering efficacy, patients (%) reaching target IOP determined at V1, hyperemia score, physician and patient assessment of study treatment tolerability at V3, and AE frequency/severity. A subgroup analysis of patients receiving the most common study treatment was conducted. All analyses were performed using the safety population (patients who received one or more doses and had any data available). Results Of 358 enrolled patients, 60.6% had primary open-angle glaucoma, 29.9% had secondary open-angle glaucoma (protocol amendment), and 13.1% had OHT; 13 patients had multiple diagnoses. At V3, the mean IOP change from baseline was ≥−4.2 mmHg (≥21.1%). IOP met or was lower than the target in 81.7% of patients, 95% exhibited none to mild conjunctival hyperemia (most common AE), and tolerability was rated good/very good by >91.1% of patients and physicians. The results were similar in patients who received the most common study treatment, bimatoprost 0.03%/timolol 0.5% (bim/tim; n=310). Conclusion PGA/P-containing medications, including bim/tim, significantly reduced IOP in previously treated patients with open-angle glaucoma or OHT; most reached their target IOP or an IOP even lower than their target and reported good/very good tolerability. PGA/P-containing medications such as bim/tim should be considered as a safe, effective therapeutic option for Turkish patients who exhibit poor response, tolerance, or adherence to their previous therapy. PMID:28458511
A dynamic study of the anterior cruciate ligament of the knee using an open MRI.
Guenoun, Daphne; Vaccaro, Julien; Le Corroller, Thomas; Barral, Pierre-Antoine; Lagier, Aude; Pauly, Vanessa; Coquart, Benjamin; Coste, Joel; Champsaur, Pierre
2017-03-01
Recent anatomical and radiological studies of the anterior cruciate ligament (ACL) suggest the ACL length and orientation change during knee flexion, and an open MRI sequencing during knee flexion enables a dynamic ACL analysis. This study's goal is to describe a normal ACL using a 1T open MRI and, in particular, variations in length and insertion angles at different degrees of flexion. Twenty-one volunteers with clinically healthy knees received a dynamic MRI with their knees in hyperextension, neutral position, and flexed at 45° and 90° angles. For each position, two radiologists measured the ACL lengths and angles of the proximal insertion between the ACL's anterior edge and the roof of the inter-condylar notch. Additionally, we measured the ACL's and the tibial plateau's distal angle insertion between their anterior edges and then compared these with the nonparametric Wilcoxon test. The ACL had a significant extension between the 90° flexion and all other positions (hyperextension: 31.75 ± 2.5 mm, neutral position: 32.5 ± 2.6 mm, 45°: 35.6 ± 1.6 mm, 90°: 35.6 ± 1.6 mm). There was also a significant increase of the angle insertion between the proximal 90° flexion and all other positions, as well as between hyperextension and bending to 45° (hyperextension: 2.45° ± 3.7°, neutral: 13.4° ± 9.7°, 45°: 33 25 ± 9.3, 90: 51.85° ± 9.3°). Additionally, there is a significant increase in the distal angle insertion for all positions (hyperextension: 133.2° ± 5.4°, neutral position: 134.95° ± 4.4°, 45°: 138.35° ± 5.9°, 90°: 149.15° ± 8.6°). Our study is the first to exhibit that a dynamic MRI has a significant ACL extension in vivo during bending. This concept opens the way for further studies to improve the diagnosis of traumatic ACL injuries using a dynamic MRI.
A method to measure internal contact angle in opaque systems by magnetic resonance imaging.
Zhu, Weiqin; Tian, Ye; Gao, Xuefeng; Jiang, Lei
2013-07-23
Internal contact angle is an important parameter for internal wettability characterization. However, due to the limitation of optical imaging, methods available for contact angle measurement are only suitable for transparent or open systems. For most of the practical situations that require contact angle measurement in opaque or enclosed systems, the traditional methods are not effective. Based upon the requirement, a method suitable for contact angle measurement in nontransparent systems is developed by employing MRI technology. In the Article, the method is demonstrated by measuring internal contact angles in opaque cylindrical tubes. It proves that the method also shows great feasibility in transparent situations and opaque capillary systems. By using the method, contact angle in opaque systems could be measured successfully, which is significant in understanding the wetting behaviors in nontransparent systems and calculating interfacial parameters in enclosed systems.
Zhou, Haichao; Ren, Haoyang; Li, Bing; Yu, Tao; Yang, Yunfeng
2016-07-08
?To discuss the effectiveness of limited open reduction via sinus tarsi approach using medial distraction technique in the treatment of intra-articular calcaneus fractures by comparing with open reduction and internal fixation via extensile L-shaped incision. ?A retrospective analysis was made on the clinical data of 21 patients with intra-articular calcaneus fractures treated by sinus tarsi approach combined with medial distraction technique between April 2013 and November 2014 (minimally invasive group), and 32 patients treated by extensile L-shaped incision approach between June 2012 and September 2014 (extensile incision group). No significant difference was found in gender, age, injury pattern, fracture classification, time from injury to operation, preoperative Böhler angle, Gissane angle, calcaneal varus angle, the ankle and hind-foot score of American Orthopaedic Foot and Ankle Society (AOFAS), and visual analogue scale (VAS) score between 2 groups (P>0.05), which was comparable. The operation time, wound complications, and bone healing time were recorded. The postoperative function was also evaluated by AOFAS score and VAS score. The pre-and post-operative Böhler angle, Gissane angle, and calcaneal varus angle were measured on the X-ray films, and the corrective angle was calculated. ?Sixteen patients were followed up 6-18 months (mean, 11.5 months) in the minimally invasive group, and 23 patients for 6-24 months (mean, 13.5 months) in the extensile incision group. Difference was not significant in operation time between 2 groups (t=0.929, P=0.796). No complication occurred in the minimally invasive group; partial skin flap necrosis occurred in 3 cases of the extensile incision group, was cured after dressing change. There was no loosening of implants or reduction loss in 2 groups at last follow-up. Subtalar joint stiffness occurred in 1 case of the minimally invasive group and 4 cases of the extensile incision group, and 1 patient had discomfort for the implants in the extensile incision group. The bone healing time was (9.9±0.8) weeks in the minimally invasive group, and was (10.1±0.7) weeks in the extensile incision group, showing no significant difference (t=0.613, P=0.845 ). Böhler angle, Gissane angle, calcaneal varus angle, AOFAS score, and VAS score were significantly improved at last follow-up when compared with preoperative values in 2 groups (P<0.05), but there was no significant difference between 2 groups (P>0.05), and the corrective value of angle showed no significant difference between 2 groups (P>0.05). ?Limited open reduction via sinus tarsi approach for intra-articular calcaneus fractures could reduce the incidence of wound complications effectively. Meanwhile, the medial distraction technique is helpful to correct the heel varus deformity.
Neurovascular structures of the mandibular angle and condyle: a comprehensive anatomical review.
Yang, Hun-Mu; Won, Sung-Yoon; Kim, Hee-Jin; Hu, Kyung-Seok
2015-11-01
Various surgical interventions including esthetic surgery, salivary gland excision, and open reduction of fracture have been performed in the area around the mandibular angle and condyle. This study aimed to comprehensively review the anatomy of the neurovascular structures on the angle and condyle with recent anatomic and clinical research. We provide detailed information about the branching and distributing patterns of the neurovascular structures at the mandibular angle and condyle, with reported data of measurements and proportions from previous anatomical and clinical research. Our report should serve to help practitioners gain a better understanding of the area in order or reduce potential complications during local procedures. Reckless manipulation during mandibular angle reduction could mutilate arterial branches, not only from the facial artery, but also from the external carotid artery. The transverse facial artery and superficial temporal artery could be damaged during approach and incision in the condylar area. The marginal mandibular branch of the facial nerve can be easily damaged during submandibular gland excision or facial rejuvenation treatment. The main trunk of the facial nerve and its upper and lower distinct divisions have been damaged during parotidectomy, rhytidectomy, and open reductions of condylar fractures. By revisiting the information in the present study, surgeons will be able to more accurately prevent procedure-related complications, such as iatrogenic vascular accidents on the mandibular angle and condyle, complete and partial facial palsy, gustatory sweating (Frey syndrome), and traumatic neuroma after parotidectomy.
Trabecular Meshwork Height in Primary Open-Angle Glaucoma Versus Primary Angle-Closure Glaucoma.
Masis, Marisse; Chen, Rebecca; Porco, Travis; Lin, Shan C
2017-11-01
To determine if trabecular meshwork (TM) height differs between primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG) eyes. Prospective, cross-sectional clinical study. Adult patients were consecutively recruited from glaucoma clinics at the University of California, San Francisco, from January 2012 to July 2015. Images were obtained from spectral-domain optical coherence tomography (Cirrus OCT; Carl Zeiss Meditec, Inc, Dublin, California, USA). Univariate and multivariate linear mixed models comparing TM height and glaucoma type were performed to assess the relationship between TM height and glaucoma subtype. Mixed-effects regression was used to adjust for the use of both eyes in some subjects. The study included 260 eyes from 161 subjects, composed of 61 men and 100 women. Mean age was 70 years (SD 11.77). There were 199 eyes (123 patients) in the POAG group and 61 eyes (38 patients) in the PACG group. Mean TM heights in the POAG and PACG groups were 812 ± 13 μm and 732 ± 27 μm, respectively, and the difference was significant in univariate analysis (P = .004) and in multivariate analysis (β = -88.7 [24.05-153.5]; P = .008). In this clinic-based population, trabecular meshwork height is shorter in PACG patients compared to POAG patients. This finding may provide insight into the pathophysiology of angle closure and provide assistance in future diagnosis, prevention, and management of the angle-closure spectrum of disorders. Copyright © 2017 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-01-01
... inches in length, with a right-angle bend 1/2-inch from each end. This wire is placed snugly in holes... form a top when shield is open). The interior of the draft shield shall be painted a flat black...
Code of Federal Regulations, 2014 CFR
2014-01-01
... inches in length, with a right-angle bend 1/2-inch from each end. This wire is placed snugly in holes... form a top when shield is open). The interior of the draft shield shall be painted a flat black...
Prevalence of comorbid retinal disease in patients with glaucoma at an academic medical center.
Griffith, Joseph F; Goldberg, Jeffrey L
2015-01-01
Patients with various retinal diseases and patients who have undergone retinal procedures and surgeries have an increased risk of developing ocular hypertension and glaucoma. Little is known about the epidemiology of comorbid retinal diseases in glaucoma patients. This study evaluated the prevalence of retinal comorbidities in a population of patients with five types of glaucoma. A longitudinal, retrospective study was conducted using International Classification of Disease (ICD-9) billing records from 2003 to 2010 at an academic medical center. Patients were classified as having primary open-angle glaucoma (POAG), low tension open-angle glaucoma (NTG), pigmentary open-angle glaucoma, chronic-angle closure glaucoma (CACG), or pseudoexfoliation glaucoma (PXG) if they had at least three clinic visits with the same ICD-9 code. Patients were classified as having a retinal comorbidity if they had two visits with the same code. Variables were analyzed with the independent t-test, χ (2) test, analysis of variance, or Fisher's exact test. A total of 5,154 patients had glaucoma, and 14.8% of these had a retinal comorbidity. The prevalence of comorbid retinal disease was higher in patients with POAG (15.7%) than in those with NTG (10.7%), PXG (10.1%), or pigmentary open-angle glaucoma (3.7%; P<0.05). Two hundred and two patients had diabetic retinopathy, with POAG patients (4.5%) having a higher prevalence than those with CACG (1.4%) or PXG (0.6%; P<0.001). There were 297 patients who had macular degeneration and both POAG (2.0%) and PXG patients (2.9%) had a higher prevalence of nonexudative macular degeneration than those with CACG (0%; P<0.01). Patients with comorbid retinal disease had a higher prevalence of blindness and low vision than those without comorbid retinal disease (1.97% versus 1.02%, P=0.02). The high prevalence of comorbid retinal disease and the nearly twofold increase in blindness and low vision in this population demonstrate the need for ophthalmologists to determine if patients have multiple etiologies for their vision loss. The higher prevalence of certain retinal diseases in POAG patients may reflect common pathophysiological processes that warrant further investigation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lebron, S; Yan, G; Li, J
2016-06-15
Purpose: To develop an accurate and quick multileaf collimator (MLC) calibration and quality assurance technique using an electronic portal imaging device (EPID) Methods: The MLC models used include the MLCi and Agility (Elekta Ltd). This technique consists of two 22(L)x10(W) cm{sup 2} fields with 0{sup 0} and 180{sup 0} collimator angles centered to an offset EPID. The MLC opening is estimated by calculating the profile at the image’s center in the image’s horizontal direction. Scans in the image’s vertical direction were calculated every 20 pixels in the inner 70% of estimated MLC opening. The profiles’ edges were fitted with linearmore » equations to determine the image’s rotation angle. Then, crossline profiles were scanned at the center of each leaf taking into account the leaf’s width at isocenter and the rotation angle. The profiles’ edges determine the location of the leaves’ edges and these were subtracted from the reference leaf’s position in order to determine the relative leaf offsets. The edge location of all profiles was determined by using the parameterized gradient of the penumbra region. The technique was tested against an established diode array-based method, and for different MLC systems, patterns, gantry angles, days, energies, beam modalities and MLC openings. Results: The differences between the proposed and established methods were 0.26±0.19mm. The leaf offsets’ deviation was <0.3mm (5 months period). For pattern fields, the differences between predetermined and calculated offsets were 0.18±0.18mm. The leaf offset deviation of measurements with different energies and MLC openings were <0.1mm and <0.3mm, respectively. The differences between offsets of FF and FFF beams were 0.01±0.02mm (<0.07mm). The differences between the offsets at different gantry angles were 0.08±0.15mm. Conclusion: The proposed method proved to be accurate and efficient in calculating the relative leaf offsets. Parameterized field edge is essential to obtain accurate result by eliminating the noise from EPID.« less
Precision determination of electron scattering angle by differential nuclear recoil energy method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liyanage, N.; Saenboonruang, K.
2015-12-01
The accurate determination of the scattered electron angle is crucial to electron scattering experiments, both with open-geometry large-acceptance spectrometers and ones with dipole-type magnetic spectrometers for electron detection. In particular, for small central-angle experiments using dipole-type magnetic spectrometers, in which surveys are used to measure the spectrometer angle with respect to the primary electron beam, the importance of the scattering angle determination is emphasized. However, given the complexities of large experiments and spectrometers, the accuracy of such surveys is limited and insufficient to meet demands of some experiments. In this article, we present a new technique for determination of themore » electron scattering angle based on an accurate measurement of the primary beam energy and the principle of differential nuclear recoil. This technique was used to determine the scattering angle for several experiments carried out at the Experimental Hall A, Jefferson Lab. Results have shown that the new technique greatly improved the accuracy of the angle determination compared to surveys.« less
Precision Determination of Electron Scattering Angle by Differential Nuclear Recoil Energy Method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liyanage, Nilanga; Saenboonruang, Kiadtisak
2015-09-01
The accurate determination of the scattered electron angle is crucial to electron scattering experiments, both with open-geometry large-acceptance spectrometers and ones with dipole-type magnetic spectrometers for electron detection. In particular, for small central-angle experiments using dipole-type magnetic spectrometers, in which surveys are used to measure the spectrometer angle with respect to the primary electron beam, the importance of the scattering angle determination is emphasized. However, given the complexities of large experiments and spectrometers, the accuracy of such surveys is limited and insufficient to meet demands of some experiments. In this article, we present a new technique for determination of themore » electron scattering angle based on an accurate measurement of the primary beam energy and the principle of differential nuclear recoil. This technique was used to determine the scattering angle for several experiments carried out at the Experimental Hall A, Jefferson Lab. Results have shown that the new technique greatly improved the accuracy of the angle determination compared to surveys.« less
Characteristics of a wind-actuated aerodynamic braking device for high-speed trains
NASA Astrophysics Data System (ADS)
Takami, H.; Maekawa, H.
2017-04-01
To shorten the stopping distance of the high speed trains in case of emergency, we developed a small-sized aerodynamic braking unit without use of the friction between a rail and a wheel. The developed device could actuate a pair of two drag panels with a travelling wind. However, after the drag panel fully opened, vibrational movements of the drag panel characterized by its slight flutter were repeated. In this study, to stabilize the opened panel, matters pertaining to the angle of attack with respect to the drag panel and pertaining to the arrangement of the two panels were examined by a wind tunnel experiment using a scale model. As a result, to stabilize the opened panel and to keep the good performance of the braking device, it is found out that an angle of attack of 75 to 80 degrees is suitable provided that the interval of the two panels is narrow enough.
Bito, Haruhiko; Takeuchi, Ryohei; Kumagai, Ken; Aratake, Masato; Saito, Izumi; Hayashi, Riku; Sasaki, Yohei; Aota, Yoichi; Saito, Tomoyuki
2009-04-01
Obtaining a correct postoperative limb alignment is an important factor in achieving a successful clinical outcome after an opening-wedge high tibial osteotomy (OWHTO). To better predict some of the aspects that impact upon the clinical outcomes following this procedure, including postoperative correction loss and over correction, we examined the changes in the frontal plane of the lower limb in a cohort of patients who had undergone OWHTO using radiography. Forty-two knees from 33 patients (23 cases of osteoarthritis and 10 of osteonecrosis) underwent a valgus realignment OWHTO procedure and were radiographically assessed for changes that occurred pre- and post-surgery. The mean femorotibial angle (FTA) was found to be 182.1 +/- 2.0 degrees (12 +/- 2.0 anatomical varus angulation) preoperatively and 169.6 +/- 2.4 degrees (10.4 +/- 2.4 anatomical valgus angulation) postoperatively. These measurements thus revealed significant changes in the weight bearing line ratio (WBL), femoral axis angle (FA), tibial axis angle (TA), tibia plateau angle (TP), tibia vara angle (TV) and talar tilt angle (TT) following OWHTO. In contrast, no significant change was found in the weight bearing line angle (WBLA) after these treatments. To assess the relationship between the correction angle and these indexes, 42 knees were divided into the following three groups according to the postoperative FTA; a normal correction group (168 degrees < or = FTA < or = 172 degrees ), an over-correction group (FTA < 168 degrees ), and an under-correction group (FTA > 172 degrees ). There were significant differences in the delta angle [DA; calculated as (pre FTA - post FTA) - (pre TV - post TV)] among each group of patients. Our results thus indicate a negative correlation between the DA and preoperative TA (R(2) = 0.148, p < 0.05). Hence, given that the correction errors in our patients appear to negatively correlate with the preoperative TA, postoperative malalignments are likely to be predictable prior to surgery.
Zhou, Yixin; Wang, Kexin; Chen, Shuang; Zhang, Jianxin; Zhou, Mingjie
2017-01-01
This study tested emerging adult couples’ openness and its fit effect on their romantic relationship quality using quadratic polynomial regression and response surface analysis. Participants were 260 emerging adult dyads. Both dyads’ openness and relationship quality were measured. The result showed that (1) female and male openness contribute differently to relationship quality; (2) couples with similar high openness could experience better relationship quality than those with similar low openness traits; and (3) when dyadic openness is dissimilar, it is better to be either relatively high or relatively low than to be moderate. These findings highlight the role of openness in emerging adults’ romantic relationships from a dyadic angle. PMID:28360875
Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael
2016-01-01
Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm(2). Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9-54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier-Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair.
Shabsigh, Muhammad; Lawrence, Cassidy; Rosero-Britton, Byron R.; Kumar, Nicolas; Kimura, Satoshi; Durda, Michael Andrew; Essandoh, Michael
2016-01-01
Mitral stenosis (MS) after mitral valve (MV) repair is a slowly progressive condition, usually detected many years after the index MV surgery. It is defined as a mean transmitral pressure gradient (TMPG) >5 mmHg or a mitral valve area (MVA) <1.5 cm2. Pannus formation around the mitral annulus or extending to the mitral leaflets is suggested as the main mechanism for developing delayed MS after MV repair. On the other hand, early stenosis is thought to be a direct result of an undersized annuloplasty ring. Furthermore, in MS following ischemic mitral regurgitation (MR) repair, subvalvular tethering is the hypothesized pathophysiology. MS after MV repair has an incidence of 9–54%. Several factors have been associated with a higher risk for developing MS after MV repair, including the use of flexible Duran annuloplasty rings versus rigid Carpentier–Edwards rings, complete annuloplasty rings versus partial bands, small versus large anterior leaflet opening angle, and anterior leaflet tip opening length. Intraoperative echocardiography can measure the anterior leaflet opening angle, the anterior leaflet tip opening dimension, the MVA and the mean TMPG, and may help identify patients at risk for developing MS after MV repair. PMID:27148540
A platform for dynamic simulation and control of movement based on OpenSim and MATLAB.
Mansouri, Misagh; Reinbolt, Jeffrey A
2012-05-11
Numerical simulations play an important role in solving complex engineering problems and have the potential to revolutionize medical decision making and treatment strategies. In this paper, we combine the rapid model-based design, control systems and powerful numerical method strengths of MATLAB/Simulink with the simulation and human movement dynamics strengths of OpenSim by developing a new interface between the two software tools. OpenSim is integrated with Simulink using the MATLAB S-function mechanism, and the interface is demonstrated using both open-loop and closed-loop control systems. While the open-loop system uses MATLAB/Simulink to separately reproduce the OpenSim Forward Dynamics Tool, the closed-loop system adds the unique feature of feedback control to OpenSim, which is necessary for most human movement simulations. An arm model example was successfully used in both open-loop and closed-loop cases. For the open-loop case, the simulation reproduced results from the OpenSim Forward Dynamics Tool with root mean square (RMS) differences of 0.03° for the shoulder elevation angle and 0.06° for the elbow flexion angle. MATLAB's variable step-size integrator reduced the time required to generate the forward dynamic simulation from 7.1s (OpenSim) to 2.9s (MATLAB). For the closed-loop case, a proportional-integral-derivative controller was used to successfully balance a pole on model's hand despite random force disturbances on the pole. The new interface presented here not only integrates the OpenSim and MATLAB/Simulink software tools, but also will allow neuroscientists, physiologists, biomechanists, and physical therapists to adapt and generate new solutions as treatments for musculoskeletal conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.
A platform for dynamic simulation and control of movement based on OpenSim and MATLAB
Mansouri, Misagh; Reinbolt, Jeffrey A.
2013-01-01
Numerical simulations play an important role in solving complex engineering problems and have the potential to revolutionize medical decision making and treatment strategies. In this paper, we combine the rapid model-based design, control systems and powerful numerical method strengths of MATLAB/Simulink with the simulation and human movement dynamics strengths of OpenSim by developing a new interface between the two software tools. OpenSim is integrated with Simulink using the MATLAB S-function mechanism, and the interface is demonstrated using both open-loop and closed-loop control systems. While the open-loop system uses MATLAB/Simulink to separately reproduce the OpenSim Forward Dynamics Tool, the closed-loop system adds the unique feature of feedback control to OpenSim, which is necessary for most human movement simulations. An arm model example was successfully used in both open-loop and closed-loop cases. For the open-loop case, the simulation reproduced results from the OpenSim Forward Dynamics Tool with root mean square (RMS) differences of 0.03° for the shoulder elevation angle and 0.06° for the elbow flexion angle. MATLAB’s variable step-size integrator reduced the time required to generate the forward dynamic simulation from 7.1 s (OpenSim) to 2.9 s (MATLAB). For the closed-loop case, a proportional–integral–derivative controller was used to successfully balance a pole on model’s hand despite random force disturbances on the pole. The new interface presented here not only integrates the OpenSim and MATLAB/Simulink software tools, but also will allow neuroscientists, physiologists, biomechanists, and physical therapists to adapt and generate new solutions as treatments for musculoskeletal conditions. PMID:22464351
Levet, Y
2014-12-01
Short noses are not only depending on the length of the dorsum, but also if there is a saddle deformity, or a too lower situation of the fronto-nasal angle, or an open naso-labial angle or a rim retraction. All the cases are treated, often with the help of cartilage grafts and with a closed approach. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
3. Elevation view of entire midsection using ultrawide angle lens. ...
3. Elevation view of entire midsection using ultrawide angle lens. Note opened south doors and closed north doors. The following photo WA-203-C-4 is similar except the camera position was moved right to include the slope of the south end. - Puget Sound Naval Shipyard, Munitions Storage Bunker, Naval Ammunitions Depot, South of Campbell Trail, Bremerton, Kitsap County, WA
Colliding Stellar Winds Structure and X-ray Emission
NASA Astrophysics Data System (ADS)
Pittard, J. M.; Dawson, B.
2018-04-01
We investigate the structure and X-ray emission from the colliding stellar winds in massive star binaries. We find that the opening angle of the contact discontinuity (CD) is overestimated by several formulae in the literature at very small values of the wind momentum ratio, η. We find also that the shocks in the primary (dominant) and secondary winds flare by ≈20° compared to the CD, and that the entire secondary wind is shocked when η ≲ 0.02. Analytical expressions for the opening angles of the shocks, and the fraction of each wind that is shocked, are provided. We find that the X-ray luminosity Lx∝η, and that the spectrum softens slightly as η decreases.
Efficiency of geometric designs of flexible solar panels: mathematical simulation
NASA Astrophysics Data System (ADS)
Marciniak, Malgorzata; Hassebo, Yasser; Enriquez-Torres, Delfino; Serey-Roman, Maria Ignacia
2017-09-01
The purpose of this study is to analyze various surfaces of flexible solar panels and compare them to the traditional at panels mathematically. We evaluated the efficiency based on the integral formulas that involve flux. We performed calculations for flat panels with different positions, a cylindrical panel, conical panels with various opening angles and segments of a spherical panel. Our results indicate that the best efficiency per unit area belongs to particular segments of spherically-shaped panels. In addition, we calculated the optimal opening angle of a cone-shaped panel that maximizes the annual accumulation of the sun radiation per unit area. The considered shapes are presented below with a suggestion for connections of the cells.
Acoustic metamaterials with broadband and wide-angle impedance matching
NASA Astrophysics Data System (ADS)
Liu, Chenkai; Luo, Jie; Lai, Yun
2018-04-01
We propose a general approach to design broadband and wide-angle impedance-matched acoustic metamaterials. Such an unusual acoustic impedance matching characteristic can be well explained by using a spatially dispersive effective medium theory. For demonstrations, we used silicone rubber, which has a huge impedance contrast with water, to design one- and two-dimensional acoustic structures which are almost perfectly impedance matched to water for a wide range of incident angles and in a broad frequency band. Our work opens up an approach to realize extraordinary acoustic impedance matching properties via metamaterial-design techniques.
Glazebrook, Mark; Copithorne, Peter; Boyd, Gordon; Daniels, Timothy; Lalonde, Karl-André; Francis, Patricia; Hickey, Michael
2014-10-01
Hallux valgus with an increased intermetatarsal angle is usually treated with a proximal metatarsal osteotomy. The proximal chevron osteotomy is commonly used but is technically difficult. This study compares the proximal opening wedge osteotomy of the first metatarsal with the proximal chevron osteotomy for the treatment of hallux valgus with an increased intermetatarsal angle. This prospective, randomized multicenter (three-center) study was based on the clinical outcome scores of the Short Form-36, the American Orthopaedic Foot & Ankle Society forefoot questionnaire, and the visual analog scale for pain, activity, and patient satisfaction. Subjects were assessed prior to surgery and at three, six, and twelve months postoperatively. Surgeon preference was evaluated based on questionnaires and the operative times required for each procedure. No significant differences were found for any of the patients' clinical outcome measurements between the two procedures. The proximal opening wedge osteotomy was found to lengthen, and the proximal chevron osteotomy was found to shorten, the first metatarsal. The intermetatarsal angles improved (decreased) significantly, from 14.8° ± 3.2° to 9.1° ± 2.9 (mean and standard deviation) after a proximal opening wedge osteotomy and from 14.6° ± 3.9° to 11.3° ± 4.0° after a proximal chevron osteotomy (p < 0.05 for both). Operative time required for performing a proximal opening wedge osteotomy is similar to that required for performing a proximal chevron osteotomy (mean and standard deviation, 67.1 ± 16.5 minutes compared with 69.9 ± 18.6 minutes; p = 0.510). Opening wedge and proximal chevron osteotomies have comparable radiographic outcomes and comparable clinical outcomes for pain, satisfaction, and function. The proximal opening wedge osteotomy lengthens, and the proximal chevron osteotomy shortens, the first metatarsal. The proximal opening wedge osteotomy was subjectively less technically demanding and was preferred by the orthopaedic surgeons in this study. Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Lo, Jonathan S; Pang, Pierre M; Lo, Samuel C
2016-01-01
Fixed combination glaucoma medication is increasingly used in glaucoma treatment. There is a lack of comparative study in the literature of non-beta blocker combination agents used adjunctively with a glaucoma agent in a different class. The objective of this study is to evaluate the effect of intraocular pressure (IOP) control and tolerability of non-beta blocker combination suspension with prostaglandin analogs (PGA) in patients with open angle glaucoma who were previously treated with beta blocker combination solution with PGA. Open-label retrospective review of patient records. This study looked at patients with open angle glaucoma taking dorzolamide/timolol solution with PGA that were switched to brinzolamide/brimonidine combination suspension with PGA. This study reviewed the charts of all patients who were at least 21 years old with a clinical diagnosis of open-angle glaucoma or ocular hypertension in at least one eye. Patients needed to have been treated with concomitant use of PGA and dorzolamide/timolol solution for at least one month. Patients using dorzolamide/timolol solution plus PGA with medication related ocular irritation were switched to brinzolamide/brimonidine suspension with the same PGA. Best-corrected visual acuity, ocular hyperemia grading, slit lamp biomicroscopy and Goldmann applanation tonometry measurements, and patient medication preferences were assessed at baseline, 1 month and 3 months. Forty eyes with open angle glaucoma. The mean age of the patients was 68 and 60% were females. The IOP before the switch was 17.2 and 16.5 (P=0.70) following the switch at 3 months. We found a decreasing trend of ocular hyperemia (P=0.064) and strong preference (P=0.011) for non-beta blocker combination suspension but no difference of visual acuity and slit lamp findings. Brinzolamide/brimonidine combination suspension when used adjunctively with PGA is equally effective. Patients in this study reported greatly reduced ocular redness and shorter duration of stinging with non-beta blocker combination suspension. Their preference of it over dorzolamide/timolol combination solution makes it a viable treatment option, particularly for the aging glaucoma patient with comorbidities that restrict the beta blocker use.
NASA Technical Reports Server (NTRS)
Norman, Timothy L.; Anglin, Colin
1995-01-01
The unnotched and notched (open hole) tensile strength and failure mechanisms of two-dimensional (2D) triaxial braided composites were examined. The effect of notch size and notch position were investigated. Damage initiation and propagation in notched and unnotched coupons were also examined. Theory developed to predict the normal stress distribution near an open hole and failure for tape laminated composites was evaluated for its applicability to 2D triaxial braided textile composite materials. Four different fiber architectures were considered; braid angle, yarn and braider size, percentage of longitudinal yarns and braider angle varied. Tape laminates equivalent to textile composites were also constructed for comparison. Unnotched tape equivalents were stronger than braided textiles but exhibited greater notch sensitivity. Notched textiles and tape equivalents have roughly the same strength at large notch sizes. Two common damage mechanisms were found: braider yarn cracking and near notch longitudinal yarn splitting. Cracking was found to initiate in braider yarns in unnotched and notched coupons, and propagate in the direction of the braider yarns until failure. Damage initiation stress decreased with increasing braid angle. No significant differences in prediction of near notch strain between textile and tape equivalents could be detected for small braid angle, but the correlations were weak for textiles with large braid angle. Notch strength could not be predicted using existing anisotropic theory for braided textiles due to their insensitivity to notch.
Practical Tests with the "auto Control Slot." Part II : Discussion
NASA Technical Reports Server (NTRS)
Lachmann, G
1930-01-01
For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.
Practical Tests with the "auto Control Slot." Part I : Lecture
NASA Technical Reports Server (NTRS)
Lachmann, G
1930-01-01
For some time the D.V.L. has been investigating the question of applicability of Handley Page slotted wings to German airplanes. Comparitive gliding tests were made with open and closed slots on an Albatros L 75 airplane equipped with the Handley Page "auto control slots." This investigation served to determine the effect of the auto control slot on the properties and performances of airplanes at large angles of attack. The most important problems were whether the angle of glide at small angles of attack can be increased by the adoption of the auto control slot and, in particular, as to whether the flight characteristics at large angles of attack are improved thereby and equilibrium in gliding flight is guaranteed even at larger than ordinary angles of attack.
Open-loop GPS signal tracking at low elevation angles from a ground-based observation site
NASA Astrophysics Data System (ADS)
Beyerle, Georg; Zus, Florian
2016-04-01
For more than a decade space-based global navigation satellite system (GNSS) radio occultation (RO) observations are used by meteorological services world-wide for their numerical weather prediction models. In addition, climate studies increasingly rely on validated GNSS-RO data sets of atmospheric parameters. GNSS-RO profiles typically cover an altitude range from the boundary layer up to the upper stratosphere; their highest accuracy and precision, however, are attained at the tropopause level. In the lower troposphere, multipath ray propagation tend to induce signal amplitude and frequency fluctuations which lead to the development and implementation of open-loop signal tracking methods in GNSS-RO receiver firmwares. In open-loop mode the feed-back values for the carrier tracking loop are derived not from measured data, but from a Doppler frequency model which usually is extracted from an atmospheric climatology. In order to ensure that this receiver-internal parameter set, does not bias the carrier phase path observables, dual-channel open-loop GNSS-RO signal tracking was suggested. Following this proposal the ground-based "GLESER" (GPS low-elevation setting event recorder) campaign was established. Its objective was to disproof the existence of model-induced frequency biases using ground-based GPS observations at very low elevation angles. Between January and December 2014 about 2600 validated setting events, starting at geometric elevation angles of +2° and extending to -1°… - 1.5°, were recorded by the single frequency "OpenGPS" GPS receiver at a measurement site located close to Potsdam, Germany (52.3808°N, 13.0642°E). The study is based on the assumption that these ground-based observations may be used as proxies for space-based RO measurements, even if the latter occur on a one order of magnitude faster temporal scale. The "GLESER" data analysis shows that the open-loop Doppler model has negligible influence on the derived frequency profile provided signal-to-noise density ratios remain above about 30 dB Hz. At low signal levels, however, the dual-channel open-loop design, which tracks the same signal using two Doppler models separated by a 10 Hz offset, reveals a notable bias. A significant fraction of this bias is caused by frequency aliasing. The receiver's dual-channel setup, however, allows for unambiguous identification of the affected observation samples. Finally, the repeat patterns in terms of azimuth angle of the GPS orbit traces reveals characteristic signatures in both, signal amplitude and Doppler frequency with respect to the topography close to the observation site. On the other hand, mean vertical refractivity gradients extracted from ECMWF meteorological fields exhibit moderate correlations with observed signal amplitude fluctuations at negative elevation angles emphasizing the information content of low-elevation GPS signals with respect to the atmospheric state in the boundary layer.
APOBEC3B upregulation and genomic mutation patterns in serous ovarian carcinoma
Leonard, Brandon; Hart, Steven N.; Burns, Michael B.; Carpenter, Michael A.; Temiz, Nuri A.; Rathore, Anurag; Vogel, Rachel Isaksson; Nikas, Jason B.; Law, Emily K.; Brown, William L.; Li, Ying; Zhang, Yuji; Maurer, Matthew J.; Oberg, Ann L.; Cunningham, Julie M.; Shridhar, Viji; Bell, Debra A.; April, Craig; Bentley, David; Bibikova, Marina; Cheetham, R. Keira; Fan, Jian-Bing; Grocock, Russell; Humphray, Sean; Kingsbury, Zoya; Peden, John; Chien, Jeremy; Swisher, Elizabeth M.; Hartmann, Lynn C.; Kalli, Kimberly R.; Goode, Ellen L.; Sicotte, Hugues; Kaufmann, Scott H.; Harris, Reuben S.
2013-01-01
Ovarian cancer is a clinically and molecularly heterogeneous disease. The driving forces behind this variability are unknown. Here we report wide variation in expression of the DNA cytosine deaminase APOBEC3B, with elevated expression in a majority of ovarian cancer cell lines (3 standard deviations above the mean of normal ovarian surface epithelial cells) and high grade primary ovarian cancers. APOBEC3B is active in the nucleus of several ovarian cancer cell lines and elicits a biochemical preference for deamination of cytosines in 5′TC dinucleotides. Importantly, examination of whole-genome sequence from 16 ovarian cancers reveals that APOBEC3B expression correlates with total mutation load as well as elevated levels of transversion mutations. In particular, high APOBEC3B expression correlates with C-to-A and C-to-G transversion mutations within 5′TC dinucleotide motifs in early-stage high grade serous ovarian cancer genomes, suggesting that APOBEC3B-catalyzed genomic uracil lesions are further processed by downstream DNA ‘repair’ enzymes including error-prone translesion polymerases. These data identify a potential role for APOBEC3B in serous ovarian cancer genomic instability. PMID:24154874
DOE Office of Scientific and Technical Information (OSTI.GOV)
Luck, L.A.; Falke, J.J.
1991-07-02
The Escherichia coli D-galactose and D-glucose receptor is a two-domain structure with a sugar-binding site at the interface between domains. The structure of the closed cleft containing bound D-glucose has been determined crystalloghraphically, but the open cleft remains to be characterized. The present study illustrates a generalizable approach that is used to detect and analyze both the open- and closed-cleft conformations in solution. A {sup 19}F nucleus located inside the cleft is monitored by {sup 19}F NMR. When the cleft is occupied by D-glucose, the {sup 19}F nucleus is found to be inaccessible to the aqueous paramagnetic probe Gd{center dot}EDTA,more » verifying that the occupied cleft is closed in solution and inaccessible to bulk solvent. When the cleft is empty, the {sup 19}F nucleus becomes accessible to the paramagnet such that the distance of closest approach is r {le} 10 {angstrom}, indicating that the empty cleft opens at least transiently by an angle {theta} {ge} 18 {plus minus} 3{degrees}.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mizuta, Akira; Ioka, Kunihito
We investigate the jet propagation and breakout from the stellar progenitor for gamma-ray burst (GRB) collapsars by performing two-dimensional relativistic hydrodynamic simulations and analytical modeling. We find that the jet opening angle is given by θ{sub j} ∼ 1/5Γ{sub 0} and infer the initial Lorentz factor of the jet at the central engine, Γ{sub 0}, is a few for existing observations of θ{sub j}. The jet keeps the Lorentz factor low inside the star by converging cylindrically via collimation shocks under the cocoon pressure and accelerates at jet breakout before the free expansion to a hollow-cone structure. In this newmore » picture, the GRB duration is determined by the sound crossing time of the cocoon, after which the opening angle widens, reducing the apparent luminosity. Some bursts violating the maximum opening angle θ{sub j,{sub max}} ∼ 1/5 ∼ 12° imply the existence of a baryon-rich sheath or a long-acting jet. We can explain the slopes in both Amati and Yonetoku spectral relations using an off-centered photosphere model, if we make only one assumption that the total jet luminosity is proportional to the initial Lorentz factor of the jet. We also numerically calibrate the pre-breakout model (Bromberg et al.) for later use.« less
Abu Hussein, Nahla B.; Habib, Ahmed E.; El Sayed, Yasmine M.
2016-01-01
Purpose. To examine causes as well as extent of delay in diagnosis and treatment of primary open angle glaucoma patients in a sample of Egyptians. Patients and Methods. 440 patients with primary open angle glaucoma were interviewed to evaluate delay in their diagnosis and treatment. The extent and cause of delay were investigated. The total delay interval, if any, was correlated with socioeconomic and other factors. Results. The median total delay was one year, with 50% of patients having a total delay of 1 year or less, of which 25% exhibited zero total delay. 25% of patients had a delay ranging from 1 to 3 years, and 25% had a total delay ranging from 3 to 27 years. Diagnostic delay accounted for 43.03% of cases. Longer delays were met in patients with certain socioeconomic factors. Patients with a positive family history of glaucoma displayed shorter delay periods. Conclusion. Significant delay in the diagnosis and treatment of glaucoma was found. Poor socioeconomic status seems to hinder timely diagnosis and treatment of POAG. Certain socioeconomic factors seem to correlate with the extent of delay. More effort is thus needed to subsidize the cost of investigations and treatment for glaucoma patients. PMID:28116140
Modifiable factors in the management of glaucoma: a systematic review of current evidence.
Hecht, Idan; Achiron, Asaf; Man, Vitaly; Burgansky-Eliash, Zvia
2017-04-01
Primary open angle glaucoma is a chronic optic neuropathy affecting millions of people worldwide and represents a major public health issue. Environmental factors, behaviors, and diet are intimately related to patient health and may play a role in the pathogenesis and progression of glaucoma. This study aims to review the literature, focusing on the last three years, regarding modifiable lifestyle interventions in the management of primary open angle glaucoma. Electronic databases were searched for studies published between January 2013 and July 2016 on the topic of lifestyle interventions in primary open angle glaucoma. Sleeping with the head elevated and avoiding the worst eye-dependent side during sleep may slightly lower intraocular pressure and reduce visual field loss. Some food supplements and moderate aerobic exercise may also reduce intraocular pressure up to 2.0 and 3.0 mmHg, respectively. Frequency of coffee intake may be associated with disease progression. Potential negative effects are associated with weight-lifting and yoga exercises. Certain lifestyle habits could influence glaucoma progression, yet no specific interventions are currently supported by robust evidence. Awareness of the possible influences of certain habits should help guide clinical advice and is important to help patients avoid adverse outcomes and take an active role in the management of their disease.
Law, Simon K
2007-01-01
The goal of treatment for open-angle glaucoma or ocular hypertension is to improve quality of life through reduction of intraocular pressure (IOP) to preserve visual function. Prostaglandins, as a newer class of ocular hypotensive agents, have been shown to be effective in IOP reduction by the primary mechanism of action of increase the uveoscleral outflow. Bimatoprost is a member this class, but different from the other members by having an ethyl amide group rather than an isopropyl ester at the C-1 carbon of the alpha chain. Bimatoprost used once daily has been shown to be more effect in IOP reduction than other classes of topical ocular hypotensive agents including beta-blockers, carbonic anhydrase inhibitors, and alpha agonists. Comparing with other topical prostaglandins, bimatoprost may be slightly more effective in IOP reduction, but the clinical significance is uncertain. The commonly reported adverse events associated with bimatoprost are localized to the eye and include conjunctival hyperemia, changes in the pigmentation of the periocular skin and iris, and eyelash darkening and growth. It is currently approved by the Food and Drug Administration (FDA) and the European Commission (EC) for first-line therapy for the reduction of elevated IOP in patients with open-angle glaucoma or ocular hypertension. PMID:19668476
Caldwell, Michael S.; Bee, Mark A.
2014-01-01
The ability to reliably locate sound sources is critical to anurans, which navigate acoustically complex breeding choruses when choosing mates. Yet, the factors influencing sound localization performance in frogs remain largely unexplored. We applied two complementary methodologies, open and closed loop playback trials, to identify influences on localization abilities in Cope’s gray treefrog, Hyla chrysoscelis. We examined localization acuity and phonotaxis behavior of females in response to advertisement calls presented from 12 azimuthal angles, at two signal levels, in the presence and absence of noise, and at two noise levels. Orientation responses were consistent with precise localization of sound sources, rather than binary discrimination between sources on either side of the body (lateralization). Frogs were unable to discriminate between sounds arriving from forward and rearward directions, and accurate localization was limited to forward sound presentation angles. Within this region, sound presentation angle had little effect on localization acuity. The presence of noise and low signal-to-noise ratios also did not strongly impair localization ability in open loop trials, but females exhibited reduced phonotaxis performance consistent with impaired localization during closed loop trials. We discuss these results in light of previous work on spatial hearing in anurans. PMID:24504182
Ebrahimi, N; Claus, B; Lee, C-Y; Biondi, A; Benndorf, G
2007-05-01
Radiographic visibility of self-expandable intracranial stents is insufficient for assessment of conformability and deployment characteristics. The purpose of this study was to evaluate stent mechanics in a curved vessel model by using Flat-Panel CT (FPCT). The following stents were used: Neuroform 2, Neuroform Treo, Enterprise, and LEO. All stents were bent in the same polytetrafluoroethylene tubes with various angles ranging from 150 degrees to 30 degrees . To visualize potential prolapse of the stent struts, 4-, 5-, and 8-mm openings were created. FPCTs were obtained using a C-arm with flat detector. FPCT scans provided excellent visualization of deployment characteristics and stent mechanics and was superior to digital subtraction angiography (DSA) and digital radiography (DR). The Neuroform2/Treo showed, with increasing angle and diameter of the opening, a continuous increase in cell size. These stents also showed an outward prolapse at the convexity and an inwards prolapse of struts at the concavity of the curvature. The Enterprise showed an increasing trend to flatten and to kink with curvatures that are more acute. The LEO showed fewer trends to kink but an inward crimping of its ends with more acute angles. Deployment characteristics and conformability to a curved vessel model vary considerably, depending on the angle and the stent design. Adverse mechanics such as increased cell opening, strut prolapse, flattening, and kinking occur during stent placement in a curved vessel model, and may gain clinical importance. FPCT is superior to DSA and DR in visualizing small metallic stents and enables accurate detection of adverse stent mechanics.
Likhvantseva, V G; Sokolov, V A; Levanova, O N; Kovelenova, I V
2018-01-01
Prediction of the clinical course of primary open-angle glaucoma (POAG) is one of the main directions in solving the problem of vision loss prevention and stabilization of the pathological process. Simple statistical methods of correlation analysis show the extent of each risk factor's impact, but do not indicate the total impact of these factors in personalized combinations. The relationships between the risk factors is subject to correlation and regression analysis. The regression equation represents the dependence of the mathematical expectation of the resulting sign on the combination of factor signs. To develop a technique for predicting the probability of development and progression of primary open-angle glaucoma based on a personalized combination of risk factors by linear multivariate regression analysis. The study included 66 patients (23 female and 43 male; 132 eyes) with newly diagnosed primary open-angle glaucoma. The control group consisted of 14 patients (8 male and 6 female). Standard ophthalmic examination was supplemented with biochemical study of lacrimal fluid. Concentration of matrix metalloproteinase MMP-2 and MMP-9 in tear fluid in both eyes was determined using 'sandwich' enzyme-linked immunosorbent assay (ELISA) method. The study resulted in the development of regression equations and step-by-step multivariate logistic models that can help calculate the risk of development and progression of POAG. Those models are based on expert evaluation of clinical and instrumental indicators of hydrodynamic disturbances (coefficient of outflow ease - C, volume of intraocular fluid secretion - F, fluctuation of intraocular pressure), as well as personalized morphometric parameters of the retina (central retinal thickness in the macular area) and concentration of MMP-2 and MMP-9 in the tear film. The newly developed regression equations are highly informative and can be a reliable tool for studying of the influence vector and assessment of pathogenic potential of the independent risk factors in specific personalized combinations.
Analysis of Balance Ability Dependent on the Angle of the Knee Joint in Females in Their 20s
Yoon, Se-Won; Lee, Jeong-Woo; Cho, Woon-Su; Kim, An-Na; Lee, Kyung-Hee
2013-01-01
The aim of this study was to investigate how balance ability according to angle of the knee joint changes in young female adults wearing a knee orthosis. [Methods] This study was conducted with 11 healthy female adults. The subjects used a knee brace that could be set to angles of 0°, 15°, and 30° of knee flexion. The ability to balance was evaluated by balance assessment. A total of four postures were used for measurements: a forward-facing posture with the eyes open on a stable surface (NO), a forward-facing posture with the eyes closed on a stable surface (NC), a forward-facing posture with the eyes open on an unstable surface (PO), and a forward-facing posture with the eyes closed on an unstable surface (PC). [Results] Regarding the weight distribution index and stability index on a stable surface, there was no interaction according to whether there was visual deprivation or not or according to knee flexion angle. Furthermore, the stability index on an unstable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. But the WDI on a stable surface showed no interaction according to whether there was visual deprivation or not or according to knee flexion angle. [Conclusion] There were significant differences in the knee extension range of motion of normal elderly people and knee osteoarthritis, and the quadriceps femoris played an important role in knee function in individuals with knee osteoarthritis. PMID:24259902
Azuara-Blanco, Augusto; Burr, Jennifer M; Cochran, Claire; Ramsay, Craig; Vale, Luke; Foster, Paul; Friedman, David; Quayyum, Zahidul; Lai, Jimmy; Nolan, Winnie; Aung, Tin; Chew, Paul; McPherson, Gladys; McDonald, Alison; Norrie, John
2011-05-23
Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care.EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible.The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events.A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. ISRCTN44464607.
Masoodi, Habibeh; Jafarzadehpur, Ebrahim; Esmaeili, Alireza; Abolbashari, Fereshteh; Ahmadi Hosseini, Seyed Mahdi
2014-08-01
To evaluate changes of nasal and temporal anterior chamber angle (ACA) in subjects with angle closure glaucoma using Spectralis AS-OCT (SAS-OCT) under dark and light conditions. Based on dark-room gonioscopy, 24 subjects with open angles and 86 with narrow angles participated in this study. The nasal and temporal angle opening distance at 500 μm anterior to the scleral spur (AOD500), nasal and temporal ACA were measured using SAS-OCT in light and dark conditions. In 2 groups, ACA and AOD500 in nasal and temporal quadrants were significantly greater in light compared to dark (all with p=0.000). The AOD500 and ACA were significantly higher in nasal than temporal in measured conditions for 2 groups except the ACA and AOD500 of normal group measured in light. The difference between nasal and temporal in dark (29.07 ± 65.71 μm for AOD500 and 5.7 ± 4.07° for ACA) was greater than light (24.86 ± 79.85 μm for AOD500 and 2.09 ± 7.21° for ACA) condition. But the difference was only significant for ACA (p=0.000). The correlation analysis showed a negative correlation between AOD500 and pupil diameter in temporal and nasal quadrants (both with p=0.000). While temporal AOD500 difference correlated with spherical equivalent, temporal and asal gonioscopy, nasal AOD correlated with IOP, temporal and nasal gonioscopy. Clinically important changes in ACA structure could be detected with SAS-OCT in nasal and temporal quadrants under different illumination intensity. The results could help in improvement of examination condition for better and more accurate assessment of individuals with angle closure glaucoma. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Q; Snyder, K; Liu, C
Purpose: To develop an optimization algorithm to reduce normal brain dose by optimizing couch and collimator angles for single isocenter multiple targets treatment of stereotactic radiosurgery. Methods: Three metastatic brain lesions were retrospectively planned using single-isocenter volumetric modulated arc therapy (VMAT). Three matrices were developed to calculate the projection of each lesion on Beam’s Eye View (BEV) by the rotating couch, collimator and gantry respectively. The island blocking problem was addressed by computing the total area of open space between any two lesions with shared MLC leaf pairs. The couch and collimator angles resulting in the smallest open areas weremore » the optimized angles for each treatment arc. Two treatment plans with and without couch and collimator angle optimization were developed using the same objective functions and to achieve 99% of each target volume receiving full prescription dose of 18Gy. Plan quality was evaluated by calculating each target’s Conformity Index (CI), Gradient Index (GI), and Homogeneity index (HI), and absolute volume of normal brain V8Gy, V10Gy, V12Gy, and V14Gy. Results: Using the new couch/collimator optimization strategy, dose to normal brain tissue was reduced substantially. V8, V10, V12, and V14 decreased by 2.3%, 3.6%, 3.5%, and 6%, respectively. There were no significant differences in the conformity index, gradient index, and homogeneity index between two treatment plans with and without the new optimization algorithm. Conclusion: We have developed a solution to the island blocking problem in delivering radiation to multiple brain metastases with shared isocenter. Significant reduction in dose to normal brain was achieved by using optimal couch and collimator angles that minimize total area of open space between any of the two lesions with shared MLC leaf pairs. This technique has been integrated into Eclipse treatment system using scripting API.« less
The influence of third molars in the line of mandibular angle fractures on wound and bone healing.
Ulbrich, N; Ettl, T; Waiss, W; Gosau, M; Moralis, A; Reichert, T E; Mueller, S
2016-07-01
The objective of this study was to evaluate postoperative complications after removal or retention of the third molar in the line of mandibular angle fractures. This retrospective study included the data of 98 patients with a molar in the line of a mandibular angle fracture treated with internal reduction and mini-plate fixation at our department over 9 years. Patients were classified into two groups: tooth removal during osteosynthesis (n = 45) and tooth retention (n = 55). The primary target criterion was the incidence of minor (outpatient treatment, local measures) and major (surgical revision, rehospitalisation) complications. Time between trauma and surgery was 1.4 days (range 0 to 12), and the average follow-up 291 days (range 66 to 863). Regarding the eruption status, 26 of 52 (50.0 %) impacted third molars, 11 of 19 (57.9 %) incompletely erupted and 8 of 27 (29.6 %) completely erupted molars had been removed during open reduction. Overall, 17 (17.3 %) patients had postoperative minor (n = 7) or major (n = 10) complications, in detail 10/45 (22.0 %) patients after tooth removal and 7/55 (13 %) patients after tooth retention (p = 0.286). Complication rates between impacted and incompletely erupted third molars (impacted molars 15.0 %, incompletely erupted molars 10.0 %) did not differ significantly, but completely erupted molars had a complication rate of 26.0 %. Mandibular angle fractures with a completely erupted third molar show the highest complication rate after open reduction and osteosynthesis. Retention of a non-infectious third molar facilitates open reduction and does not increase the complication risk. The study helps with the decision of removing or retention of a third molar during surgical treatment of a mandibular angle fracture.
Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka
2004-12-01
To evaluate and compare the findings and changes of the anterior chamber angle configuration with indentation ultrasound biomicroscopy (UBM) gonioscopy in relative pupillary block (RPB), peripheral anterior synechia (PAS), and plateau iris configuration (PIC). This study included 73 eyes of 52 patients with RPB (n = 26), PAS (n = 21), or PIC (n = 26). First, a conventional UBM scan was performed using a normal size standard eye cup before indentation. Then, for indentation UBM gonioscopy, scans were performed using a new eye cup that we designed. For evaluation of the angle, angle opening distance 500 and angle recess area were recorded and evaluated with regard to the effect of expansion on the anterior chamber angle. Indentation UBM gonioscopy showed the characteristic images in each of the eyes. The angle of all examined eyes was significantly widened with indentation (P < 0.01). The angle changes in eyes with RPB were significantly greater than in eyes with PAS or PIC (P < 0.01). Indentation UBM gonioscopy is a very useful method for observing the angle and diagnosis of RPB, PAS, and PIC.
NASA Astrophysics Data System (ADS)
Stens, C.; Riedelbauch, S.
2017-04-01
Due to a more fluctuating energy production caused by renewable energies such as wind and solar power, the number of changes between operating points in pumped storage power plants has increased over the last years. To further increase available regulating power, it is desirable to speed up these changes of operation conditions in Hydro units. Previous studies showed that CFD is well capable of predicting the flow phenomena in the machine under unsteady conditions for a large guide vane opening angle. The present paper investigates the benefits of nearly closed guide vanes during the transition. Results are compared between the two different angles as well as between simulation and measurement.
Nonimaging Optical Illumination System
Winston, Roland
1994-02-22
A nonimaging illumination or concentration optical device. An optical device is provided having a light source, a light reflecting surface with an opening and positioned partially around the light source which is opposite the opening of the light reflecting surface. The light reflecting surface is disposed to produce a substantially uniform intensity output with the reflecting surface defined in terms of a radius vector R.sub.i in conjunction with an angle .phi..sub.i between R.sub.i, a direction from the source and an angle .theta..sub.i between direct forward illumination and the light ray reflected once from the reflecting surface. R.sub.i varies as the exponential of tan (.phi..sub.i -.theta..sub.i)/2 integrated over .phi..sub.i.
NASA Astrophysics Data System (ADS)
Adib, M. R. M.; Amirza, A. R. M.; Wardah, T.; Junaidah, A.
2016-07-01
Hydraulic control gate structure plays an important role in regulating the flow of water in river, canal or water reservoir. One of the most appropriate structures in term of resolving the problem of flood occured is the construction of circular fibre steel flap gate. Therefore, an experiment has been conducted by using an open channel model at laboratory. In this case, hydraulic jump and backwater were the method to determined the hydraulic characteristics of circular fibre steel flap gate in an open channel model. From the experiment, the opening angle of flap gate can receive discharges with the highest flow rate of 0.035 m3/s with opening angle was 47°. The type of jump that occurs at the slope of 1/200 for a distance of 5.0 m is a standing jump or undulating wave. The height of the backwater can be identified based on the differences of specific force which is specific force before jump, F1 and specific force after jump, F2 from the formation of backwater. Based on the research conducted, the tendency of incident backwater wave occurred was high in every distance of water control location from water inlet is flap slope and the slope of 1/300 which is 0.84 m/s and 0.75 m/s of celerity in open channel model.
Effects of wind velocity and slope on flame properties
David R. Weise; Gregory S. Biging
1996-01-01
Abstract: The combined effects of wind velocity and percent slope on flame length and angle were measured in an open-topped, tilting wind tunnel by burning fuel beds composed of vertical birch sticks and aspen excelsior. Mean flame length ranged from 0.08 to 1.69 m; 0.25 m was the maximum observed flame length for most backing fires. Flame angle ranged from -46o to 50o...
CONTINUOUS ROTATION SCATTERING CHAMBER
Verba, J.W.; Hawrylak, R.A.
1963-08-01
An evacuated scattering chamber for use in observing nuclear reaction products produced therein over a wide range of scattering angles from an incoming horizontal beam that bombards a target in the chamber is described. A helically moving member that couples the chamber to a detector permits a rapid and broad change of observation angles without breaching the vacuum in the chamber. Also, small inlet and outlet openings are provided whose size remains substantially constant. (auth)
NASA Astrophysics Data System (ADS)
Kovacs, Geza
2018-04-01
The distribution of the stellar rotation axes of 113 main sequence stars in the open cluster Praesepe are examined by using current photometric rotation periods, spectroscopic rotation velocities, and estimated stellar radii. Three different samples of stellar rotation data on spotted stars from the Galactic field and two independent samples of planetary hosts are used as control samples to support the consistency of the analysis. Considering the high completeness of the Praesepe sample and the behavior of the control samples, we find that the main sequence F - K stars in this cluster are susceptible to rotational axis alignment. Using a cone model, the most likely inclination angle is 76° ± 14° with a half opening angle of 47° ± 24°. Non-isotropic distribution of the inclination angles is preferred over the isotropic distribution, except if the rotation velocities used in this work are systematically overestimated. We found no indication of this being the case on the basis of the currently available data. Data are only available at the CDS, together with the other two compiled datasets used in this paper, via anonymous ftp to http://cdsarc.u-strasbg.fr (http://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/612/L2
Bone morphotypes of the varus and valgus knee.
Thienpont, E; Schwab, P E; Cornu, O; Bellemans, J; Victor, J
2017-03-01
Coronal deformity correction with total knee arthroplasty (TKA) is an important feature in the treatment of osteoarthritis (OA). The hypothesis of this study was that bone morphology would be different in varus and valgus deformity, both before osteoarthritis development as well as during and after the disease process of OA. Retrospective study with measurements on preoperative and postoperative full leg standing radiographs of 96 patients who underwent TKA. The included patients were selected for this study because they had an OA knee on one side and a non-arthritic knee on the contralateral side presenting the same type of alignment as the to-be-operated knee (varus or valgus alignment on both sides). The control group of 46 subjects was a group of patients with neutral mechanical alignment who presented for ligamentous problems. A single observer measured mechanical alignment, anatomical alignment, anatomical-mechanical femoral angle and intra-articular bone morphology parameters with an accuracy of 1°. Varus OA group has less distal femoral valgus (mLDFA 89°) than control group (87°) and valgus OA group (mLDFA 85°). Varus OA group has same varus obliquity as control group (MPTA 87°) but more than valgus OA group (MPTA 90°). Joint Line Congruency Angle (JLCA) is 3°open on lateral side in varus and medially open in valgus OA group (2°). The non-arthritic valgus group presents a constitutional mechanical valgus of 184° Hip-Knee-Ankle (HKA) angle. Varus deformity in OA as measured with an HKA angle (HKA) <177° is a combination of distal femoral wear, tibial varus obliquity and lateral joint line opening. Valgus deformity in OA with an HKA > 183° is a combination of femoral distal joint line obliquity and wear combined with medial opening due to medial collateral ligament stretching. The clinical importance of bone morphotype analysis is that it shows the intra-articular potential of alignment correction when mechanical axis cuts are performed. Bone morphology in varus and valgus deformity is different before and after osteoarthritis. Perpendicular cuts to mechanical axes do not necessarily lead to neutral mechanical axis. Constitutional mechanical valgus was observed as 184° HKA angle before the development of OA. Level IV study.
Relationship Between Anterior Lamina Cribrosa Surface Tilt and Glaucoma Development in Myopic Eyes.
Lee, Eun Jung; Han, Jong Chul; Kee, Changwon
2017-05-01
To evaluate the anterior lamina cribrosa (LC) surface tilt angle in myopic eyes and associate it with glaucoma development. In this retrospective study, medical records of myopic patients referred for glaucoma examination from July 1, 2012 to March 30, 2016 were reviewed. Comprehensive ophthalmic examination including spectral-domain optical coherence tomography were performed. We measured the angle of anterior LC surface tilt against Bruch's membrane opening from optical coherence tomography images at the center of the clinical optic disc margin. In horizontal and vertical sections, the angles were defined as α and β, respectively. Patients were grouped according to the presence of glaucomatous damage and factors including optic nerve head morphologic parameters and LC tilt angles were compared between the 2 groups. Among 138 patients originally enrolled, 102 patients were finally analyzed. One eye from 1 patient was randomly chosen. Fifty-five eyes had glaucoma and 47 were normal. The degree of myopia and all optic nerve head morphologic parameters were not significantly different between the 2 groups. However, |α| and |β| were significantly larger in the glaucoma group (all P<0.001), and significances were maintained in multivariate analysis (P<0.001). Larger anterior LC surface tilt angles were related to the presence of glaucoma in normal-pressure myopic eyes. Angulation of the LC against Bruch's membrane opening plane might be associated with increased glaucoma susceptibility in myopic eyes. Further investigations are warranted before clinical utilization of LC tilt as glaucoma susceptibility biomarker.
Open-field arena boundary is a primary object of exploration for Drosophila
Soibam, Benjamin; Mann, Monica; Liu, Lingzhi; Tran, Jessica; Lobaina, Milena; Kang, Yuan Yuan; Gunaratne, Gemunu H; Pletcher, Scott; Roman, Gregg
2012-01-01
Drosophila adults, when placed into a novel open-field arena, initially exhibit an elevated level of activity followed by a reduced stable level of spontaneous activity and spend a majority of time near the arena edge, executing motions along the walls. In order to determine the environmental features that are responsible for the initial high activity and wall-following behavior exhibited during exploration, we examined wild-type and visually impaired mutants in arenas with different vertical surfaces. These experiments support the conclusion that the wall-following behavior of Drosophila is best characterized by a preference for the arena boundary, and not thigmotaxis or centrophobicity. In circular arenas, Drosophila mostly move in trajectories with low turn angles. Since the boundary preference could derive from highly linear trajectories, we further developed a simulation program to model the effects of turn angle on the boundary preference. In an hourglass-shaped arena with convex-angled walls that forced a straight versus wall-following choice, the simulation with constrained turn angles predicted general movement across a central gap, whereas Drosophila tend to follow the wall. Hence, low turn angled movement does not drive the boundary preference. Lastly, visually impaired Drosophila demonstrate a defect in attenuation of the elevated initial activity. Interestingly, the visually impaired w1118 activity decay defect can be rescued by increasing the contrast of the arena's edge, suggesting that the activity decay relies on visual detection of the boundary. The arena boundary is, therefore, a primary object of exploration for Drosophila. PMID:22574279
NASA Astrophysics Data System (ADS)
Rockenschaub, M.; Grasemann, B.; Iglseder, C.; Rice, A. H. N.; Schneider, D.; Zamolyi, A.
2010-05-01
Roll-back of the African Plate within the Eurasian-African collision zone since the Oligocene/Miocene led to extension in the Cyclades along low-angle normal fault zones and exhumation of rocks from near the brittle-ductile transition zone. On the island of Kea (W Cyclades), which represents such a crustal scale low-angle fault zone with top-to-SSW kinematics, remote sensing analysis of brittle fault lineaments in the Pissis area (W Kea) demonstrates two dominant strike directions: ca. NE-SW and NW-SE. From the north of Pisses southwards, the angle between the two main fault directions changes gradually from a rhombohedral geometry (ca. 50°/130° angle between faults, with the acute angle facing westwards) to an orthogonal geometry. The aim of this study is the development of this fault system. We investigate, if this fault system is related to the Miocene extension or if it is related to a later overprinting event (e.g. the opening of the Corinth) Field observations revealed that the investigated lineaments are high-angle (50-90° dip) brittle/ductile conjugate, faults. Due to the lack of marker layers offsets could only rarely be estimated. Locally centimetre thick marble layers in the greenschists suggest a displacement gradient along the faults with a maximum offset of less than 60 cm. Large displacement gradients are associated with a pronounced ductile fault drag in the host rocks. In some instances, high-angle normal faults were observed to link kinematically with low-angle, top-to-SSW brittle/ductile shear bands. Both the high- and the low-angle faults have a component of ductile shear, which is overprinted by brittle deformation mechanisms. In thin-section, polyphase mode-2 cracks are filled mainly with calcite and quartz (ultra)cataclasites, sometimes followed by further opening with fluid-related iron-rich carbonate (ankeritic) precipitation. CL analysis reveals several generations of cements, indicating multiple phases of cataclastic deformation and fluid infiltration. Ar/Ar white mica data from Pisses constrain ductile deformation to ca. 20 Ma. Since the high-angle faults show a continuum from ductile to brittle deformation, the Ar/Ar cooling ages suggest that faulting must have occurred in the Miocene. Consequently the high-angle faulting was genetically related to the SSW-directed low-angle extensional event and does not represent a later overprint related to a different kinematic event.
Large-angle cosmic microwave background anisotropies in an open universe
NASA Technical Reports Server (NTRS)
Kamionkowski, Marc; Spergel, David N.
1994-01-01
If the universe is open, scales larger than the curvature scale may be probed by observation of large-angle fluctuations in the cosmic microwave background (CMB). We consider primordial adiabatic perturbations and discuss power spectra that are power laws in volume, wavelength, and eigenvalue of the Laplace operator. Such spectra may have arisen if, for example, the universe underwent a period of `frustated' inflation. The resulting large-angle anisotropies of the CMB are computed. The amplitude generally increases as Omega is decreased but decreases as h is increased. Interestingly enough, for all three Ansaetze, anisotropies on angular scales larger than the curvature scale are suppressed relative to the anisotropies on scales smaller than the curvature scale, but cosmic variance makes discrimination between various models difficult. Models with 0.2 approximately less than Omega h approximately less than 0.3 appear compatible with CMB fluctuations detected by Cosmic Background Explorer Satellite (COBE) and the Tenerife experiment and with the amplitude and spectrum of fluctuations of galaxy counts in the APM, CfA, and 1.2 Jy IRAS surveys. COBE normalization for these models yields sigma(sub 8) approximately = 0.5 - 0.7. Models with smaller values of Omega h when normalized to COBE require bias factors in excess of 2 to be compatible with the observed galaxy counts on the 8/h Mpc scale. Requiring that the age of the universe exceed 10 Gyr implies that Omega approximately greater than 0.25, while requiring that from the last-scattering term in the Sachs-Wolfe formula, large-angle anisotropies come primarily from the decay of potential fluctuations at z approximately less than 1/Omega. Thus, if the universe is open, COBE has been detecting temperature fluctuations produced at moderate redshift rather than at z approximately 1300.
Paredes, Igor; Panero, Irene; Cepeda, Santiago; Castaño-Leon, Ana M; Jimenez-Roldan, Luis; Perez-Nuñez, Ángel; Alén, Jose A; Lagares, Alfonso
2018-06-14
This study aimed to compare the accuracy of screw placement between open pedicle screw fixation and percutaneous pedicle screw fixation (MIS) for the treatment of thoracolumbar spine fractures (TSF). Forty-nine patients with acute TSF who were treated with transpedicular screw fixation from January 2013 to December 2016 were retrospectively reviewed. The patients were divided into Open and MIS groups. Laminectomy was performed in either group if needed. The accuracy of the screw placement, the evolution of the Cobb sagital angle postoperatively and at 12-month follow up and the neurological status were recorded. AO type of fracture and TLICS score were also recorded. Mean age was 42 years old. Mean TLICS score was 6,29 and 5,96 for open and MIS groups respectively. Twenty five MIS and 24 open surgeries were performed, and 350 (175 in each group) screws were inserted (7,14 per patient). Twenty-four and 13 screws were considered ̈out ̈ in the open and MIS groups respectively (Odds ratio 1,98. 0,97-4,03 p=0,056). The Cobb sagittal angle went from 13,3o to 4,5o and from 14,9o to 8,2o in the Open and MIS groups respectively (both p<0,0001). Loss of correction at 12-month follow up was 3,2o and 4,2o for the open and MIS groups respectively. No neurological worsening was observed. For the treatment of acute thoracolumbar fractures, the MIS technique seems to achieve similar results to the open technique in relation to neurological improvement and deformity correction, while placing the screws more accurately.
Optimal Control of Airfoil Flow Separation using Fluidic Excitation
NASA Astrophysics Data System (ADS)
Shahrabi, Arireza F.
This thesis deals with the control of flow separation around a symmetric airfoils with the aid of multiple synthetic jet actuators (SJAs). CFD simulation methods have been implemented to uncover the flow separation regimes and associated properties such as frequencies and momentum ratio. In the first part of the study, the SJA was studied thoroughly. Large Eddy Simulations (LES) were performed for one individual cavity; the time history of SJA of the outlet velocity profile and the net momentum imparted to the flow were analyzed. The studied SJA is asymmetrical and operates with the aid of a piezoelectric (PZT) ceramic circular plate actuator. A three-dimensional mesh for the computational domain of the SJA and the surrounding volume was developed and was used to evaluate the details of the airflow conditions inside the SJA as well as at the outlet. The vibration of the PZT ceramic actuator was used as a boundary condition in the computational model to drive the SJA. Particular attention was given to developing a predictive model of the SJA outlet velocity. Results showed that the SJA velocity output is correlated to the PZT ceramic plate vibration, especially for the first frequency mode. SJAs are a particular class of zero net mass flux (ZNMF) fluidic devices with net imparted momentum to the flow. The net momentum imparted to the flow in the separated region is such that positive enhancement during AFC operations is achieved. Flows around the NACA 0015 airfoil were simulated for a range of operating conditions. Attention was given to the active open and closed loop control solutions for an airfoil with SJA at different angles of attack and flap angles. A large number of simulations using RANS & LES models were performed to study the effects of the momentum ratio (Cμ) in the range of 0 to 11% and of the non-dimensional frequency, F+, in the range of 0 to 2 for the control of flow separation at a practical angle of attack and flap angle. The optimum value of Cμ as well as F+ were evaluated and discussed. The computational model predictions showed good agreement with the experimental data. It was observed that different angles of attack and flap angles have different requirements for the minimum value of the momentum coefficient, Cμ, in order for the SJA to be effective for control of separation. It was also found that the variation of F + noticeably affects the lift and drag forces acting on the airfoil. The optimum values of parameters during open loop control simulations have been applied in order to introduce the optimal open loop control outcome. An innovative approach has been implemented to formulate optimal frequencies and momentum ratios of vortex shedding which depends on angle of attack and static pressure of the separation zone in the upper chord. Optimal open loop results have been compared with the optimal closed loop results. Cumulative case studies in the matter of angle of attacks, flap angles, Re, Cμ and F+ provide a convincing collection of evidence to the following conclusion. An improvement of a direct closed loop control was demonstrated, and an analytical formula describing the properties of a separated flow and vortex shedding was proposed. Best AFC solutions are offered by providing optimal frequencies and momentum ratios at a variety of flow conditions.
NASA Astrophysics Data System (ADS)
Han, Qinkai; Chu, Fulei
2012-12-01
It is well known that either the asymmetric disk or transverse crack brings parametric inertia (or stiffness) excitation to the rotor-bearing system. When both of them appear in a rotor system, the parametric instability behaviors have not gained sufficient attentions. Thus, the effect of transverse crack upon parametric instability of a rotor-bearing system with an asymmetric disk is studied. First, the finite element equations of motion are established for the asymmetric rotor system. Both the open and breathing transverse cracks are taken into account in the model. Then, the discrete state transition matrix (DSTM) method is introduced for numerically acquiring the instability regions. Based upon these, some computations for a practical asymmetric rotor system with open or breathing transverse crack are conducted, respectively. Variations of the primary and combination instability regions induced by the asymmetric disk with the crack depth are observed, and the effect of the orientation angle between the crack and asymmetric disk on various instability regions are discussed in detail. It is shown that for the asymmetric angle around 0, the existence of transverse (either open or breathing) crack has attenuation effect upon the instability regions. Under certain crack depth, the instability regions could be vanished by the transverse crack. When the asymmetric angle is around π/2, increasing the crack depth would enhance the instability regions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sunden, S.L.F.; Nichols, B.E.; Alward, W.L.M.
Juvenile onset primary open angle glaucoma has been mapped by linkage to 1q21-q31. Several candidate genes were evaluated in the same family used to identify the primary linkage. Atrionatriuretic peptide receptor A (NPR1) and laminin C1 (LAMC1) have been previously mapped to this region and could putatively play a role in the pathogenesis of glaucoma. A third gene, the peripheral cannabis receptor (CNR2) was not initially mapped in humans but was a candidate because of the relief that cannabis affords some patients with primary open angle glaucoma. Microsatellites associated with NPR1 and LAMC1 revealed multiple recombinations in affected members ofmore » this pedigree. CNR2 was shown to be on chromosome 1 by PCR amplification of a 150 bp fragment of the 3{prime} untranslated region in monochromosomal somatic cell hybrids (NIGMS panel No. 2). These primers also revealed a two allele single strand conformation polymorphism which showed multiple recombinants with juvenile onset primary open angle glaucoma in large pedigrees, segregating this disorder. The marker was then mapped to 1p34-p36 by linkage, with the most likely location between liver alkaline phosphatase (ALPL) and alpha-L-1 fucosidase (FUCA1).« less
Gurney, J C; Ansari, E; Harle, D; O'Kane, N; Sagar, R V; Dunne, M C M
2018-02-09
To determine the accuracy of a Bayesian learning scheme (Bayes') applied to the prediction of clinical decisions made by specialist optometrists in relation to the referral refinement of chronic open angle glaucoma. This cross-sectional observational study involved collection of data from the worst affected or right eyes of a consecutive sample of cases (n = 1,006) referred into the West Kent Clinical Commissioning Group Community Ophthalmology Team (COT) by high street optometrists. Multilevel classification of each case was based on race, sex, age, family history of chronic open angle glaucoma, reason for referral, Goldmann Applanation Tonometry (intraocular pressure and interocular asymmetry), optic nerve head assessment (vertical size, cup disc ratio and interocular asymmetry), central corneal thickness and visual field analysis (Hodapp-Parrish-Anderson classification). Randomised stratified tenfold cross-validation was applied to determine the accuracy of Bayes' by comparing its output to the clinical decisions of three COT specialist optometrists; namely, the decision to discharge, follow-up or refer each case. Outcomes of cross-validation, expressed as means and standard deviations, showed that the accuracy of Bayes' was high (95%, 2.0%) but that it falsely discharged (3.4%, 1.6%) or referred (3.1%, 1.5%) some cases. The results indicate that Bayes' has the potential to augment the decisions of specialist optometrists.
Anterior Chamber Angle Shape Analysis and Classification of Glaucoma in SS-OCT Images.
Ni Ni, Soe; Tian, J; Marziliano, Pina; Wong, Hong-Tym
2014-01-01
Optical coherence tomography is a high resolution, rapid, and noninvasive diagnostic tool for angle closure glaucoma. In this paper, we present a new strategy for the classification of the angle closure glaucoma using morphological shape analysis of the iridocorneal angle. The angle structure configuration is quantified by the following six features: (1) mean of the continuous measurement of the angle opening distance; (2) area of the trapezoidal profile of the iridocorneal angle centered at Schwalbe's line; (3) mean of the iris curvature from the extracted iris image; (4) complex shape descriptor, fractal dimension, to quantify the complexity, or changes of iridocorneal angle; (5) ellipticity moment shape descriptor; and (6) triangularity moment shape descriptor. Then, the fuzzy k nearest neighbor (fkNN) classifier is utilized for classification of angle closure glaucoma. Two hundred and sixty-four swept source optical coherence tomography (SS-OCT) images from 148 patients were analyzed in this study. From the experimental results, the fkNN reveals the best classification accuracy (99.11 ± 0.76%) and AUC (0.98 ± 0.012) with the combination of fractal dimension and biometric parameters. It showed that the proposed approach has promising potential to become a computer aided diagnostic tool for angle closure glaucoma (ACG) disease.
NASA Astrophysics Data System (ADS)
Lewis, B. J.; Cimbala, J. M.; Wouden, A. M.
2014-03-01
At their best efficiency point (BEP), hydroturbines operate at very high efficiency. However, with the ever-increasing penetration of alternative electricity generation, it has become common to operate hydroturbines at off-design conditions in order to maintain stability in the electric power grid. This paper demonstrates a method for improving hydroturbine performance during off-design operation by injecting water through slots at the trailing edges of the wicket gates. The injected water causes a change in bulk flow direction at the inlet of the runner. This change in flow angle from the wicket gate trailing-edge jets provides the capability of independently varying the flow rate and swirl angle through the runner, which in current designs are both determined by the wicket gate opening angle. When properly tuned, altering the flow angle results in a significant improvement in turbine efficiency during off-design operation.
Evaluation of eyes with relative pupillary block by indentation ultrasound biomicroscopy gonioscopy.
Matsunaga, Koichi; Ito, Kunio; Esaki, Koji; Sugimoto, Kota; Sano, Toru; Miura, Katsuya; Sasoh, Mikio; Uji, Yukitaka
2004-03-01
To investigate changes in anterior chamber angle configuration with indentation ultrasound biomicroscopy gonioscopy of relative pupillary block (RPB). Cross-sectional study. This study included 26 eyes of 26 patients with RPB. We determined angle opening distance 500 and angle recess area using indentation ultrasound biomicroscopy gonioscopy and compared a small-sized standard eye cup with a new eye cup with an area for inducing pressure. Indentation ultrasound biomicroscopy images documented concavity of the iris in eyes with RPB. Both the new and the small standard eye cups widened the anterior chamber angle significantly (P <.0001) without causing corneal damage. Angle changes were significantly greater for the new eye cup design. Indentation ultrasound biomicroscopy gonioscopy is a useful technique for observation and diagnosis of RPB. Using a small standard or the newly designed eye cup, the procedure can be performed easily and without causing corneal damage.
Angle stations in or for endless conveyor belts
Steel, Alan
1987-04-07
In an angle station for an endless conveyor belt, there are presented to each incoming run of the belt stationary curved guide members (18, 19) of the shape of a major segment of a right-circular cylinder and having in the part-cylindrical portion (16 or 17) thereof rectangular openings (15) arranged in parallel and helical paths and through which project small freely-rotatable rollers (14), the continuously-changing segments of the curved surfaces of which projecting through said openings (15) are in attitude to change the direction of travel of the belt (13) through 90.degree. during passage of the belt about the part-cylindrical portion (16 or 17) of the guide member (18 or 19). The rectangular openings (15) are arranged with their longer edges lengthwise of the diagonals representing the mean of the helix but with those of a plurality of the rows nearest to each end of the part-cylindrical portion (16 or 17) slightly out of axial symmetry with said diagonals, being slightly inclined in a direction about the intersections (40) of the diagonals of the main portion of the openings, to provide a "toe-in" attitude in relation to the line of run of the endless conveyor belt.
Optical coherence tomography in anterior segment imaging
Kalev-Landoy, Maya; Day, Alexander C.; Cordeiro, M. Francesca; Migdal, Clive
2008-01-01
Purpose To evaluate the ability of optical coherence tomography (OCT), designed primarily to image the posterior segment, to visualize the anterior chamber angle (ACA) in patients with different angle configurations. Methods In a prospective observational study, the anterior segments of 26 eyes of 26 patients were imaged using the Zeiss Stratus OCT, model 3000. Imaging of the anterior segment was achieved by adjusting the focusing control on the Stratus OCT. A total of 16 patients had abnormal angle configurations including narrow or closed angles and plateau irides, and 10 had normal angle configurations as determined by prior full ophthalmic examination, including slit-lamp biomicroscopy and gonioscopy. Results In all cases, OCT provided high-resolution information regarding iris configuration. The ACA itself was clearly visualized in patients with narrow or closed angles, but not in patients with open angles. Conclusions Stratus OCT offers a non-contact, convenient and rapid method of assessing the configuration of the anterior chamber. Despite its limitations, it may be of help during the routine clinical assessment and treatment of patients with glaucoma, particularly when gonioscopy is not possible or difficult to interpret. PMID:17355288
Angle closure glaucoma in congenital ectropion uvea.
Wang, Grace M; Thuente, Daniel; Bohnsack, Brenda L
2018-06-01
Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. The three cases showed 360° of ectropion uvea and iris stromal atrophy in the affected eye. In one case, we have photographic documentation of progression to complete angle closure, which necessitated placement of a glaucoma drainage device 3 years after combined trabeculotomy and trabeculectomy. The 2 other cases, which presented as complete angle closure, also underwent glaucoma drainage device implantation. All three cases had early glaucoma drainage device encapsulation (within 4 months) and required additional surgery (cycloablation or trabeculectomy). Congenital ectropion uvea can be associated with angle-closure glaucoma, and placement of glaucoma drainage devices in all 3 of our cases showed early failure due to plate encapsulation. Glaucoma in congenital ectropion uvea requires attention to angle configuration and often requires multiple surgeries to obtain intraocular pressure control.
Influence of crack opening and incident wave angle on second harmonic generation of Lamb waves
NASA Astrophysics Data System (ADS)
Yang, Yi; Ng, Ching-Tai; Kotousov, Andrei
2018-05-01
Techniques utilising second harmonic generation (SHG) have proven their great potential in detecting contact-type damage. However, the gap between the practical applications and laboratory studies is still quite large. The current work is aimed to bridge this gap by investigating the effects of the applied load and incident wave angle on the detectability of fatigue cracks at various lengths. Both effects are critical for practical implementations of these techniques. The present experimental study supported by three-dimensional (3D) finite element (FE) modelling has demonstrated that the applied load, which changes the crack opening and, subsequently, the contact nonlinearity, significantly affects the amplitude of the second harmonic generated by the fundamental symmetric mode (S0) of Lamb wave. This amplitude is also dependent on the length of the fatigue crack as well as the incident wave angle. The experimental and FE results correlate well, so the modelling approach can be implemented for practical design of damage monitoring systems as well as for the evaluation of the severity of the fatigue cracks.
Variability of single-leg versus double-leg stance radiographs in the varus knee.
Chen, Andrew; Rich, Valerie; Bain, Elizabeth; Sterett, William I
2009-07-01
We evaluated measured radiographic parameter variability between single-leg stance (SLS) and double-leg stance (DLS) radiographs in patients with varus knee malalignment, indicated for high tibial osteotomy. Fifty-three consecutive knees (mean, 49 years; range, 18-79 years) were evaluated for varus thrust. SLS and DLS radiographs were obtained. A single blinded observer measured mechanical axis angles and weight-bearing line (WBL) deviation using a goniometer. Mechanical axis angles averaged 9.1 degrees (DLS) and 11.3 degrees (SLS). SLS radiographs averaged 9% greater WBL medialization than did DLS. Medial opening averaged 16.4 mm (DLS) and 18.8 mm (SLS). DLS and SLS radiographs showed no significant differences in patients without varus thrust. Patients with varus thrust demonstrated differences in mechanical axis angles (DLS, 9.4 degrees; SLS, 12.2 degrees), WBL deviation (12.1% less), medialization (DLS), and medial opening necessary for correction (DLS, 16.6 mm; SLS, 20.3 mm). In varus thrust, SLS radiographs more closely replicate dynamic knee malalignment, possibly providing more accurate measurements of angular deformity.
Optimizing water permeability through the hourglass shape of aquaporins
Gravelle, Simon; Joly, Laurent; Detcheverry, François; Ybert, Christophe; Cottin-Bizonne, Cécile; Bocquet, Lydéric
2013-01-01
The ubiquitous aquaporin channels are able to conduct water across cell membranes, combining the seemingly antagonist functions of a very high selectivity with a remarkable permeability. Whereas molecular details are obvious keys to perform these tasks, the overall efficiency of transport in such nanopores is also strongly limited by viscous dissipation arising at the connection between the nanoconstriction and the nearby bulk reservoirs. In this contribution, we focus on these so-called entrance effects and specifically examine whether the characteristic hourglass shape of aquaporins may arise from a geometrical optimum for such hydrodynamic dissipation. Using a combination of finite-element calculations and analytical modeling, we show that conical entrances with suitable opening angle can indeed provide a large increase of the overall channel permeability. Moreover, the optimal opening angles that maximize the permeability are found to compare well with the angles measured in a large variety of aquaporins. This suggests that the hourglass shape of aquaporins could be the result of a natural selection process toward optimal hydrodynamic transport. Finally, in a biomimetic perspective, these results provide guidelines to design artificial nanopores with optimal performances. PMID:24067650
Effects of excimer laser illumination on microdrilling into an oblique polymer surface
NASA Astrophysics Data System (ADS)
Wu, Chih-Yang; Shu, Chun-Wei; Yeh, Zhi-Chang
2006-08-01
In this work, we present the experimental results of micromachining into polymethy-methacrylate exposed to oblique KrF excimer laser beams. The results of low-aspect-ratio ablations show that the ablation rate decreases monotonously with the increase of incident angle for various fluences. The ablation rate of high-aspect-ratio drilling with opening center on the focal plane is almost independent of incident angles and is less than that of low-aspect-ratio ablation. The results of high-aspect-ratio ablations show that the openings of the holes at a distance from the focal plane are enlarged and their edges are blurred. Besides, the depth of a hole in the samples oblique to the laser beam at a distance from the focal plane decreases with the increase of the distance from the focal plane. The number of deep holes generated by oblique laser beams through a matrix of apertures decreases with the increase of incident angle. Those phenomena reveal the influence of the local light intensity on microdrilling into an oblique surface.
NASA Technical Reports Server (NTRS)
Elliott, David M.
2012-01-01
A counter-rotating open rotor scale model was tested in the NASA Glenn Research Center 9- by 15-Foot Low-Speed Wind Tunnel (LSWT). This model used a historical baseline blade set with which modern blade designs will be compared against on an acoustic and aerodynamic performance basis. Different blade pitch angles simulating approach and takeoff conditions were tested, along with angle-of-attack configurations. A configuration was also tested in order to determine the acoustic effects of a pylon. The shaft speed was varied for each configuration in order to get data over a range of operability. The freestream Mach number was also varied for some configurations. Sideline acoustic data were taken for each of these test configurations.
Strong-field ionization with twisted laser pulses
NASA Astrophysics Data System (ADS)
Paufler, Willi; Böning, Birger; Fritzsche, Stephan
2018-04-01
We apply quantum trajectory Monte Carlo computations in order to model strong-field ionization of atoms by twisted Bessel pulses and calculate photoelectron momentum distributions (PEMD). Since Bessel beams can be considered as an infinite superposition of circularly polarized plane waves with the same helicity, whose wave vectors lie on a cone, we compared the PEMD of such Bessel pulses to those of a circularly polarized pulse. We focus on the momentum distributions in propagation direction of the pulse and show how these momentum distributions are affected by experimental accessible parameters, such as the opening angle of the beam or the impact parameter of the atom with regard to the beam axis. In particular, we show that we can find higher momenta of the photoelectrons, if the opening angle is increased.
Educating the glaucoma patient.
Rosenthal, A. R.; Zimmerman, J. F.; Tanner, J.
1983-01-01
Forty-nine patients with open-angle glaucoma and 32 controls were studied at each of 2 medical centres, one in California and one in England. A 12-point questionnaire was answered before, immediately after, and 6 months after viewing a 6 minute video film about glaucoma. The English glaucoma patients and controls showed lower initial knowledge than their American counterparts. Immediately after the film all groups had substantially improved their knowledge by answering 78-88% of the questions correctly. Recall study showed that both American groups had retained more than their British counterparts and that glaucoma patients retained more knowledge of their disease than did controls. The use of an educational video film in an outpatient setting is a simple and economical method of patient education applicable to both American and British subjects with open-angle glaucoma. PMID:6671096
On the 'flip-flop' instability of Bondi-Hoyle accretion flows
NASA Technical Reports Server (NTRS)
Livio, Mario; Soker, Noam; Matsuda, Takuya; Anzer, Ulrich
1991-01-01
A simple physical interpretation is advanced by means of an analysis of the shock cone in the accretion flows past a compact object and with an examination of the accretion-line stability analyses. The stability of the conical shock is examined against small angular deflections with attention given to several simplifying assumptions. A line instability is identified in the Bondi-Hoyle accretion flows that leads to the formation of a large opening-angle shock. When the opening angle becomes large the instability becomes irregular oscillation. The analytical methodology is compared to previous numerical configurations that demonstrate different shock morphologies. The Bondi-Hoyle accretion onto a compact object is concluded to generate a range of nonlinear instabilities in both homogeneous and inhomogeneous cases with a quasiperiodic oscillation in the linear regime.
Role of oxidative stress enzymes in open-angle glaucoma.
Yildirim, O; Ateş, N A; Ercan, B; Muşlu, N; Unlü, A; Tamer, L; Atik, U; Kanik, A
2005-05-01
To investigate the role of oxidative stress and lipid peroxidation in the pathogenesis of primary open-angle glaucoma (POAG). The activities of myeloperoxidase (MPO), catalase (CAT), and the levels of plasma malondialdehyde (MDA) were measured in 40 (15 men and 25 women) patients with POAG and 60 (30 men and 30 women) healthy controls. There was no significant difference in the activities of CAT and MPO between the POAG patients and the controls. However, the plasma MDA level was significantly higher in patients than the controls. The results of this preliminary study suggest that the possible alterations of plasma MDA levels may be associated with the pathogenesis of POAG, but further research is needed to understand the role of oxidative damage in this important disorder of aging.
Stationary Digital Tomosynthesis System for Early Detection of Breast Tumors
2012-05-01
Vol. 5745. 2005. 14. Y. Zhang, et al., A comparative study of limited-angle cone-beam reconstruction methods 505 for breast tomosynthesis. Med...opening angl em integratio designed line nia Dimension determine the try calibration th the detector ain is sent fro between XC urce not fou here...screening mammography. AJR, 2007. 189: p. 616. 12. P. Baldelli, et al., A prototype of a quasi-monochromatic system for mammography applications . Phys
Zhao, Jing-Xin; Su, Xiu-Yun; Zhao, Zhe; Xiao, Ruo-Xiu; Zhang, Li-Cheng; Tang, Pei-Fu
2018-02-17
The aim of this study is to demonstrate the varying rules of radiographic angles following varying three-dimensional (3D) orientations and locations of cup using an accurate mathematical model. A cone model is established to address the quantitative relationship between the opening circle of cup and its ellipse projection on radiograph. The varying rules of two-dimensional (2D) radiographic anteversion (RA) and inclination (RI) angles can be analyzed. When the centre of cup is located above X-ray source, with proper 3D RI/RA angles, 2D RA angle can be equal to its 3D counterpart, and 2D RI angle is usually greater than its 3D counterpart. Except for the original point on hip-centered anterior-posterior radiograph, there is no area on radiograph where both 2D RA and RI angles are equal to their 3D counterparts simultaneously. This study proposes an innovative model for accurately explaining how 2D RA/RI angles of cup are varying following different 3D RA/RI angles and location of cup. The analysis results provide clinicians an intuitive grasp of knowledge about 2D RA/RI angles greater or smaller than their 3D counterparts post-operatively. The established model may allow determining the effects of pelvic rotations on 2D radiographic angles of cup.
Lewine, Eliza; Kim, Jaehon M; Miller, Patricia E; Waters, Peter M; Mahan, Susan T; Snyder, Brian; Hedequist, Daniel; Bae, Donald S
2018-02-01
The purpose of this investigation was to compare the presentation and postoperative results of children treated for open and closed, completely displaced type III supracondylar humerus fractures (SCFs). Thirty patients with open and 66 patients with closed, completely displaced type III SCFs were evaluated. Open fractures underwent irrigation and debridement, and all patients were treated by open or closed reduction and pin fixation. Medical records were reviewed to obtain demographic information as well as preoperative and postoperative clinical data regarding mechanism of injury, neurovascular status, associated injuries, postoperative range of motion, infections, and pain. Radiographs were evaluated to quantify displacement, Baumann's angle, humeral capitellar angle, position of the anterior humeral line, and adequacy of reduction. Outcomes were assessed using Flynn criteria. Mean clinical follow-up for the open and closed fracture groups was 8.9 and 5.7 months, respectively. Both groups were similar with respect to age, sex distribution, weight and body mass index, laterality of involvement, and mechanism of injury. At presentation, 35% of closed SCFs and 23% of open SCFs presented with abnormal neurovascular status. There was a higher prevalence of diminished/absent pulses or distal limb ischemia in patients with open injuries (27%) compared with closed fractures (18%). Conversely, severely displaced closed fractures were more commonly associated with nerve injury/palsy at presentation (35%) than those with open fractures (23%). Spontaneous nerve recovery was seen in 87% within 3 to 6 months. Postoperative loss of reduction and malunion were more common in the closed fracture group. However, 84% of patients achieved good-to-excellent results by Flynn criteria, with no appreciable difference based upon open versus closed fractures. With timely wound and fracture treatment, the clinical and radiographic results of children treated for open SCFs is similar to those with closed type III injuries, with little increased risk for infection, malunion, or neurovascular compromise. Level III.
2011-01-01
Background Glaucoma is the leading cause of irreversible blindness. Although primary open-angle glaucoma is more common, primary angle-closure glaucoma (PACG) is more likely to result in irreversible blindness. By 2020, 5·3 million people worldwide will be blind because of PACG. The current standard care for PACG is a stepped approach of a combination of laser iridotomy surgery (to open the drainage angle) and medical treatment (to reduce intraocular pressure). If these treatments fail, glaucoma surgery (eg, trabeculectomy) is indicated. It has been proposed that, because the lens of the eye plays a major role in the mechanisms leading to PACG, early clear lens extraction will improve glaucoma control by opening the drainage angle. This procedure might reduce the need for drugs and glaucoma surgery, maintain good visual acuity, and improve quality of life compared with standard care. EAGLE aims to evaluate whether early lens extraction improves patient-reported, clinical outcomes, and cost-effectiveness, compared with standard care. Methods/Design EAGLE is a multicentre pragmatic randomized trial. All people presenting to the recruitment centres in the UK and east Asia with newly diagnosed PACG and who are at least 50 years old are eligible. The primary outcomes are EQ-5D, intraocular pressure, and incremental cost per quality adjusted life year (QALY) gained. Other outcomes are: vision and glaucoma-specific patient-reported outcomes, visual acuity, visual field, angle closure, number of medications, additional surgery (e.g., trabeculectomy), costs to the health services and patients, and adverse events. A single main analysis will be done at the end of the trial, after three years of follow-up. The analysis will be based on all participants as randomized (intention to treat). 400 participants (200 in each group) will be recruited, to have 90% power at 5% significance level to detect a difference in EQ-5D score between the two groups of 0·05, and a mean difference in intraocular pressure of 1·75 mm Hg. The study will have 80% power to detect a difference of 15% in the glaucoma surgery rate. Trial Registration: ISRCTN44464607. PMID:21605352
Tanihara, H; Honjo, M; Inatani, M; Honda, Y; Ogino, N; Ueno, S; Negi, A; Ichioka, H; Mizoguchi, T; Matsumura, M; Nagata, M
1997-10-01
The authors previously reported the usefulness of trabeculotomy ab externo for the treatment of primary open-angle glaucoma in adult patients. In an attempt to elucidate the long-term risk-to-benefit ratio of this surgical modality in combination with cataract surgery, the authors conducted a retrospective study of the surgical effects and complications of a triple procedure: phacoemulsification, implantation (of an intraocular lens), and trabeculotomy (PIT). The authors conducted a retrospective study of patients treated with PIT at multiple hospitals. Intraocular pressure (IOP) and visual function data were obtained from patients after PIT as an initial surgical treatment in cases where antiglaucoma medications failed to resolve uncontrolled IOP (higher than 21 mm Hg). Included in this study were 96 eyes of 64 patients with primary open-angle glaucoma and coexisting cataract. The mean follow-up period was 22.6 +/- 14.7 months (range 3-56 months). In 94 (98%) of the 96 eyes, the IOP was well controlled, having achieved a level of 21 mm Hg or lower at the final examinations. The mean preoperative IOP of the 33 eyes that underwent the triple procedure using a single flap method (PIT-I) was 24.3 +/- 3.9 mm Hg, with an average of 2.1 +/- 1.1 medications. At the final examinations, the mean IOP had dropped to 16.0 +/- 1.2 mm Hg, with an average of 1.2 +/- 1.2 medications. The mean preoperative IOP of the 63 eyes that underwent the triple procedure using a double flap method (PIT-II) was 26.2 +/- 6.2 mm Hg, with an average of 1.9 +/- 1.2 medications. At the final examination, the mean IOP for this group was 15.6 +/- 2.9 mm Hg, with an average of 1.0 +/- 0.9 medications. The long-term results from this multicenter study showed that the triple procedure, PIT, can be useful and effective as an initial surgical treatment for open-angle glaucoma in glaucoma patients with coexisting cataract.
Gose, Shinichi; Sakai, Takashi; Shibata, Toru; Akiyama, Keisuke; Yoshikawa, Hideki; Sugamoto, Kazuomi
2011-12-01
We evaluated the validity of the Robin and Graham classification system of hip disease in cerebral palsy (CP) using three-dimensional computed tomography in young people with CP. A total of 91 hips in 91 consecutive children with bilateral spastic CP (57 males, 34 females; nine classified at Gross Motor Function Classification System level II, 42 at level III, 32 at level IV, and eight at level V; mean age 5 y 2 mo, SD 11 mo; range 2-6 y) were investigated retrospectively using anteroposterior plain radiographs and three-dimensional computed tomography (3D-CT) of the hip. The migration percentage was calculated on plain radiographs and all participants were classified into four groups according to migration percentage: grade II, migration percentage ≥ 10% but ≤ 15%, (four hips), grade III, migration percentage >15% but ≤ 30%, (20 hips); grade IV, migration percentage >30% but <100%, (63 hips); and grade V, migration percentage ≥ 100%, (four hips). The lateral opening angle and the sagittal inclination angle of the acetabulum, the neck-shaft angle, and the femoral anteversion of the femur were measured on 3D-CT. The three-dimensional quantitative evaluation indicated that there were significant differences in the lateral opening angle and the neck-shaft angle between the four groups (Kruskal-Wallis test, p ≤ 0.001). This three-dimensional evaluation supports the validation of the Robin and Graham classification system for hip disease in 2- to 7-year-olds with CP. © The Authors. Developmental Medicine & Child Neurology © 2011 Mac Keith Press.
Sakata, Lisandro M; Lavanya, Raghavan; Friedman, David S; Aung, Han T; Gao, Hong; Kumar, Rajesh S; Foster, Paul J; Aung, Tin
2008-05-01
To compare the performance of gonioscopy and anterior segment (AS) optical coherence tomography (OCT) in detecting angle closure in the different quadrants of the anterior chamber angle (ACA). Cross-sectional observational study. Five hundred two consecutive subjects more than 50 years of age with no previous ophthalmic problems recruited from a community clinic in Singapore. All subjects underwent gonioscopy and AS OCT imaging in the dark. Using gonioscopy, the ACA was graded using the Scheie system by a single examiner masked to AS OCT findings. The ACA in a particular quadrant was classified as closed if the posterior trabecular meshwork could not be seen on gonioscopy. A closed ACA on AS OCT imaging was defined by the presence of any contact between the iris and angle wall anterior to the scleral spur. After excluding eyes with poor image quality, a total of 423 right eyes were included in the analysis. A closed angle in at least 1 quadrant was observed in 59% of the eyes by AS OCT and in 33% of the eyes by gonioscopy (P<0.001), with fair agreement between the two methods (kappa = 0.40). The frequency of closed angles by AS OCT and gonioscopy were 48% versus 29% superiorly, 43% versus 22% inferiorly, 18% versus 14% nasally, and 12% versus 20% temporally, respectively. Of the 119 of 1692 quadrants that were closed on gonioscopy but open on AS OCT, a steep iris profile was present in 61 (51%) of 119 quadrants on AS OCT, and of the 276 of 1692 quadrants that were open on gonioscopy but closed on AS OCT, 196 (71%) of 276 quadrants showed short iridoangle contact on AS OCT. The highest rates of closed angles on gonioscopy and AS OCT images were observed in the superior quadrant. Anterior segment OCT tended to detect more closed ACAs than gonioscopy, particularly in the superior and inferior quadrants. Variations in the iris profile and level of iridoangle contact also may explain some of the differences seen between gonioscopy and AS OCT.
EMIIM Wetting Properties & Their Effect on Electrospray Thruster Design
2012-03-01
tension and contact or “wetting" angle formed when a liquid droplet comes in contact with a solid surface. Ideally this angle is a function of the...3 3 Picture of a Taylor cone formed at AFRL, note bubbles present. . . . . . . 3 4 Titanium electrode grids in use at AFRL...cone formed using an internally wetted emitter and the ionic liquid BMI-BG4 is shown in Figure 3.[7] Emitters are precisely aligned with openings
Code of Federal Regulations, 2011 CFR
2011-04-01
... and, as the patient's mouth opens, the pen records on graph paper the angle between the upper and the lower jaw. (b) Classification. Class I (general controls). The device is exempt from the premarket...
Genetics Home Reference: early-onset glaucoma
... called a syndrome. If glaucoma appears before the age of 5 without other associated abnormalities, it is called primary congenital glaucoma. Other individuals experience early onset of primary open-angle glaucoma, the most ...
... is to “conduct and support research, training, health information dissemination, and other programs with respect to blinding eye ... Media Policies and Other Important Links NEI Employee Emergency Information NEI Intranet (Employees Only) *PDF files require ...
... in their Asian counterparts. Normal Tension Glaucoma affects Japanese Japanese populations, however, have a substantially higher incidence of ... factor for open angle glaucoma). In fact, a Japanese study found NTG accounted for 92 percent of ...
Gyre formation within embayments of a large lake (Lake Geneva, Switzerland)
NASA Astrophysics Data System (ADS)
Razmi, A.; Barry, D.; Bouffard, D.; Le Dantec, N.; Lemmin, U.; Wuest, A.
2013-12-01
Numerical simulations were carried out to examine gyre formation within open, wide lacustrine embayments. The present study was motivated by observed differences in gyre formation within two open and wide embayments (located at Vidy and Morges in Lake Geneva, Switzerland). These two embayments are located within about 3 km of each other on the northern shore of Lake Geneva, and are subjected to similar pelagic currents. Vidy is deeper and has a greater aspect ratio than Morges. The flow field in the embayments was modeled using a previously validated 3D hydrodynamic model (Delft3D-FLOW). The model solved the Reynolds-Averaged Navier-Stokes equations, combined with a k-ɛ turbulence closure in σ (lakebed-following) coordinates. Our study focused on the influence of the embayment geometry on the (uniform) longshore (pelagic) current, specifically the occurrence and magnitude of circulation within the embayment. We built a set of numerical experiments using synthetic embayments, and systematically examined embayment geometry, thereby capturing the differences between the Vidy and Morges embayments. The numerical experiments considered single rectilinear embayments with different aspect ratios (i.e., 1-6), depth, shore-parallel flow rates, and embayment corner angle between 0°-50°. The circulation magnitude changes abruptly for an angle of about 40°. Embayments with angles greater than 40° have much greater circulation then those with lesser angles, other factors remaining the same. Of the factors considered (i.e., aspect ratio, offshore current velocity, corner angle, bottom slope, and viscosity), bottom slope and the viscosity have almost no impact on embayment circulation. For uniform offshore current patterns, gyres form in embayments with large aspect ratios (up to ~3). For the Vidy and Morges embayments, the results showed that gyre formation is more likely in Morges due to its smaller aspect ratio, a finding that is supported by field data gathered in drifter studies. For example, simultaneous drifter releases in 2011 showed parallel-to-shore currents in the Vidy embayment and a gyre in Morges. KEYWORDS: Hydrodynamics; Open Embayment; Flow Separation; Gyre; Topography; Lake Geneva.
Apparatus For Laminating Segmented Core For Electric Machine
Lawrence, Robert Anthony; Stabel, Gerald R
2003-06-17
A segmented core for an electric machine includes segments stamped from coated electric steel. The segments each have a first end, a second end, and winding openings. A predetermined number of segments are placed end-to-end to form layers. The layers are stacked such that each of the layers is staggered from adjacent layers by a predetermined rotation angle. The winding openings of each of the layers are in vertical alignment with the winding openings of the adjacent layers. The stack of layers is secured to form the segmented core.
Mapping a gene for adult-onset primary open-angle glaucoma to chromosome 3q
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wirtz, M.K.; Samples, J.R.; Kramer, P.L.
1997-02-01
Glaucoma is the third-leading cause of blindness in the world, affecting >13.5 million people. Adult-on-set primary open-angle glaucoma (POAG) is the most common form of glaucoma in the United States. We present a family in which adult-onset POAG is inherited as an autosomal dominant trait. Twelve affected family members were identified from 44 at-risk individuals. The disease-causing gene was mapped to chromosome 3q21-24, with analysis of recombinant haplotypes suggesting a total inclusion region of 11.1 cM between markers D3S3637 and D3S1744. This is the first report of mapping of an adult-onset POAG gene to chromosome 3q, gene symbol GLC1C. 57more » refs., 3 figs., 3 tabs.« less
Liu, Ziyuan; Wang, Hongli; Fan, Dongsheng; Wang, Wei
2018-02-01
Recent studies revealing genetic connection of primary open angle glaucoma (POAG) and amyotrophic lateral sclerosis (ALS) have received particular attention. Exploring the evidence for common pathogenesis of these two progressive neurological disorders may assist in understanding the mechanism and searching for new treatment. Retinal nerve fiber layer (RNFL) defect and corresponding visual field (VF) impairment are well known neuropathy signs in glaucoma. In our study, thickness of certain retinal layer in ALS patients was analyzed to detect ganglion cell's soma and axon, and for first time visual field was examined for ALS. The correlation of retinal involvement and ALS progression were also investigated. The results were compared with those of POAG. The study may provide new knowledge for these two neurodegenerative diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.
Blindness following bleb-related infection in open angle glaucoma.
Yamada, Hiroki; Sawada, Akira; Kuwayama, Yasuaki; Yamamoto, Tetsuya
2014-11-01
To estimate the risk of blindness following bleb-related infection after trabeculectomy with mitomycin C in open angle glaucoma, utilizing data obtained from two prospective multicenter studies. The incidence of bleb-related infection in open angle glaucoma after the first or second glaucoma surgery was calculated using a Kaplan-Meier analysis and data from the Collaborative Bleb-related Infection Incidence and Treatment Study (CBIITS). The rate of blindness following bleb-related infection was calculated using data from the Japan Glaucoma Society Survey of Bleb-related Infection (JGSSBI). Finally, the rate of blindness following bleb-related infection after filtering surgery was estimated based on the above two data sets. Blindness was defined as an eye with a visual acuity of 0.04 or less. The incidences of development of bleb-related infection at 5 years were 2.6 ± 0.7 % (calculated cumulative incidence ± standard error) for all infections and 0.9 ± 0.4 % for endophthalmitis in all cases in the CBIITS data. The rates of blindness in the JGSSBI data were 14 % for the total cases with bleb-related infection and 30 % for the endophthalmitis subgroup. The rate of blindness developing within 5 years following trabeculectomy was estimated to be approximately 0.24-0.36 %. The rate of blindness following bleb-related infection within 5 years after trabeculectomy is considerable and thus careful consideration must be given to the indication for trabeculectomy and the selection of surgical techniques.
NASA Technical Reports Server (NTRS)
Norman, Timothy L.; Anglin, Colin; Gaskin, David; Patrick, Mike
1995-01-01
The unnotched and notched (open hole) tensile strength and failure mechanisms of two-dimensional (2D) triaxial braided composites were examined. The effect of notch size and notch position were investigated. Damage initiation and propagation in notched and unnotched coupons were also examined. Theory developed to predict the normal stress distribution near an open hole and failure for tape laminated composites was evaluated for its applicability to triaxial braided textile composite materials. Four fiber architectures were considered with different combinations of braid angle, longitudinal and braider yam size, and percentage of longitudinal yarns. Tape laminates equivalent to textile composites were also constructed for comparison. Unnotched tape equivalents were stronger than braided textiles but exhibited greater notch sensitivity. Notched textiles and tape equivalents have roughly the same strength at large notch sizes. Two common damage mechanisms were found: braider yams cracking and near notch longitudinal yarn splitting. Cracking was found to initiate in braider yarns in unnotched and notched coupons, and propagate in the direction of the braider yarns until failure. Longitudinal yarn splitting occurred in three of four architectures that were longitudinally fiber dominated. Damage initiation stress decreased with increasing braid angle. No significant differences in prediction of near notch stress between measured and predicted stress were weak for textiles with large braid angle. Notch strength could not be predicted using existing anisotropic theory for braided textiles due to their insensitivity to notch.
NASA Astrophysics Data System (ADS)
Pomoni, Elli; Rastelli, Leonardo
2012-10-01
We consider an instance of the AdS/CFT duality where the bulk theory contains an open string tachyon, and study the instability from the viewpoint of the boundary field theory. We focus on the specific example of the AdS5 × S 5 background with two probe D7 branes intersecting at general angles. For generic angles supersymmetry is completely broken and there is an open string tachyon between the branes. The field theory action for this system is obtained by coupling to {N}=4 super Yang-Mills two {N}=2 hyper multiplets in the fundamental representation of the SU( N) gauge group, but with different choices of embedding of the two {N}=2 subalgebras into {N}=4 . On the field theory side we find a one-loop Coleman-Weinberg instability in the effective potential for the fundamental scalars. We identify a mesonic operator as the dual of the open string tachyon. By AdS/CFT, we predict the tachyon mass for small 't Hooft coupling (large bulk curvature) and confirm that it violates the AdS stability bound.
NASA Astrophysics Data System (ADS)
Hunter, N. J. R.; Weinberg, R. F.; Wilson, C. J. L.; Law, R. D.
2018-07-01
Variations in flow kinematics influence the type of crystallographic preferred orientations (CPOs) in plastically deformed quartz, yet we currently lack a robust means of quantifying the diagnostic symmetries that develop in the c-axis (0001) pole figure. In this contribution, we demonstrate how the symmetry of common c-axis topologies may be quantified by analysing the intensity distribution across a line transect of the pole figure margin. A symmetry value (S) measures the relative difference in intensities between marginal girdle maxima in the pole figure, and thus the degree to which the pole figure defines orthorhombic or monoclinic end member symmetries. This provides a semi-quantitative depiction of whether the rocks underwent coaxial or non-coaxial flow, respectively, and may subsequently be used to quantify other topological properties, such as the opening angle of girdle maxima. The open source Matlab® toolbox MTEX is used to quantify pole figure symmetries in quartzite samples from the Main Central Thrust (NW Himalaya) and the Moine Thrust (NW Scotland).
Broadband and polarization reflectors in the lookdown, Selene vomer
Zhao, Shulei; Brady, Parrish Clawson; Gao, Meng; Etheredge, Robert Ian; Kattawar, George W.; Cummings, Molly E.
2015-01-01
Predator evasion in the open ocean is difficult because there are no objects to hide behind. The silvery surface of fish plays an important role in open water camouflage. Various models have been proposed to account for the broadband reflectance by the fish skin that involve one-dimensional variations in the arrangement of guanine crystal reflectors, yet the three-dimensional organization of these guanine platelets have not been well characterized. Here, we report the three-dimensional organization and the optical properties of integumentary guanine platelets in a silvery marine fish, the lookdown (Selene vomer). Our structural analysis and computational modelling show that stacks of guanine platelets with random yaw angles in the fish skin produce broadband reflectance via colour mixing. Optical axes of the guanine platelets and the collagen layer are aligned closely and provide bulk birefringence properties that influence the polarization reflectance by the skin. These data demonstrate how the lookdown preserves or alters polarization states at different incident polarization angles. These optical properties resulted from the organization of these guanine platelets and the collagen layer may have implications for open ocean camouflage in varying light fields. PMID:25673301
Comparing approaches to screening for angle closure in older Chinese adults
Andrews, J; Chang, D S; Jiang, Y; He, M; Foster, P J; Munoz, B; Kashiwagi, K; Friedman, D S
2012-01-01
Aims Primary angle-closure glaucoma is expected to account for nearly 50% of bilateral glaucoma blindness by 2020. This study was conducted to assess the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and limbal anterior chamber depth (LACD) as screening methods for angle closure. Methods This study assessed two clinical populations to compare SPAC, LACD, and gonioscopy: the Zhongshan Angle-closure Prevention Trial, from which 370 patients were eligible as closed-angle participants and the Liwan Eye Study, from which 72 patients were selected as open-angle controls. Eligible participants were assessed by SPAC, LACD, and gonioscopy. Results Angle status was defined by gonioscopy. Area under the receiver operating characteristic curve (AUROC) for SPAC was 0.92 (0.89–0.95) whereas AUROC for LACD was 0.94 (0.92–0.97). Using conventional cutoff points, sensitivity/specificity was 93.0%/70.8% for SPAC and 94.1%/87.5% for LACD. Sequential testing using both SPAC and LACD increased the specificity to 94.4% and decreased the sensitivity to 87.0%. Conclusion SPAC has significantly lower specificity than LACD measurement using conventional cutoffs but interpretation of the findings can be performed by modestly trained personnel. PMID:21997356
Magnetic reconnection in 3D magnetosphere models: magnetic separators and open flux production
NASA Astrophysics Data System (ADS)
Glocer, A.; Dorelli, J.; Toth, G.; Komar, C. M.; Cassak, P.
2014-12-01
There are multiple competing definitions of magnetic reconnection in 3D (e.g., Hesse and Schindler [1988], Lau and Finn [1990], and Boozer [2002]). In this work we focus on separator reconnection. A magnetic separator can be understood as the 3D analogue of a 2D x line with a guide field, and is defined by the line corresponding to the intersection of the separatrix surfaces associated with the magnetic nulls. A separator in the magnetosphere represents the intersection of four distinct magnetic topologies: solar wind, closed, open connected to the northern hemisphere, and open connected to the southern hemisphere. The integral of the parallel electric field along the separator defines the rate of open flux production, and is one measure of the reconnection rate. We present three methods for locating magnetic separators and apply them to 3D resistive MHD simulations of the Earth's magnetosphere using the BATS-R-US code. The techniques for finding separators and determining the reconnection rate are insensitive to IMF clock angle and can in principle be applied to any magnetospheric model. The present work examines cases of high and low resistivity, for two clock angles. We also examine the separator during Flux Transfer Events (FTEs) and Kelvin-Helmholtz instability.
Evaluation of a Wedge on a Force Balance as a Flow Angle Probe
1975-02-01
pitot rake attached to the Captive Trajectory System (CTS), and (3) measurement of flow angles in the same region with a probe attached to the CTS...localized pressures. Although it was the characteristics of supersonic flow which led to this conclusion, and even though the wedge design was based...vary the open area from near zero to 10 percent. Suction through the porous walls is used to maximize flow uniformity and to develop supersonic flow
Hot spots in the microwave sky
NASA Technical Reports Server (NTRS)
Vittorio, Nicola; Juszkiewicz, Roman
1987-01-01
Tha assumption that the cosmic background fluctuations can be approximated as a random Gaussian field implies specific predictions for the radiation temperature pattern. Using this assumption, the abundances and angular sizes are calculated for regions of various levels of brightness expected to appear in the sky. Different observational strategies are assessed in the context of these results. Calculations for both large-angle and small-angle anisotropy generated by scale-invariant fluctuations in a flat universe are presented. Also discussed are simple generalizations to open cosmological models.
Pelloni, S; Provasi, P F; Pagola, G I; Ferraro, M B; Lazzeretti, P
2017-12-07
The trace of tensors that account for chiroptical response of the H 2 O 2 molecule is a function of the HO-OH dihedral angle. It vanishes at 0° and 180°, due to the presence of molecular symmetry planes, but also for values in the range 90-100° of this angle, in which the molecule is unquestionably chiral. Such an atypical effect is caused by counterbalancing contributions of diagonal tensor components with nearly maximal magnitude but opposite sign, determined by electron flow in open or closed helical paths, and associated with induced electric and magnetic dipole moments and anapole moments. For values of dihedral angle external to the 90-100° interval, the helical paths become smaller in size, thus reducing the amount of cancellation among diagonal components. Shrinking of helical paths determines the appearance of extremum values of tensor traces approximately at 50° and 140° dihedral angles.
33 CFR 157.21 - Subdivision and stability.
Code of Federal Regulations, 2011 CFR
2011-07-01
... account sinkage, heel, and trim, must be below the lower edge of an opening through which progressive.... (b) In the final stage of flooding, the angle of heel due to unsymmetrical flooding must not exceed...
33 CFR 157.21 - Subdivision and stability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... account sinkage, heel, and trim, must be below the lower edge of an opening through which progressive.... (b) In the final stage of flooding, the angle of heel due to unsymmetrical flooding must not exceed...
Experimental measurements of heat transfer coefficient in a partially/fully opened tilted cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakroun, W.; Elsayed, M.M.; Al-Fahed, S.F.
1997-11-01
An experimental investigation was carried out to determine the heat transfer coefficient from a rectangular tilted cavity to the ambient due to the buoyancy driven flow in the cavity. The cavity is partially or fully open from one side. All the walls of the cavity are adiabatic except the wall facing the cavity opening which is heated at a constant heat flux. Air was used as the cavity fluid and the experiments were carried out at a flux Grashof number of 5.5 {times} 10{sup 8}. The tilt angle of the cavity, measured from the vertical direction, was changed between {minus}90more » deg to +90 deg in 15 deg increments. Also, geometries of aspect ratio (height-to-width of cavity) of 1.0, 0.5, and 0.25 and of opening ratio (opening height to cavity height) of 1.0, 0.5, and 0.25 were considered in the study. The results are presented in terms of the average Nusselt number for different values of the above experimental parameters. Conclusions are derived for the effect of changing the tilt angle, the aspect ratio, or the opening ratio of the cavity on the average heat transfer coefficient between the cavity and the ambient air. Buoyancy-driven flow in rectangular cavities has been widely investigated by many researchers. This geometry is of special interest in many solar applications such as in solar passive heating, solar concentrators, and solar central receivers. The importance of the geometry extends to other engineering applications such as electronic equipment, fire research, and energy conservation in buildings.« less
Beebe, David C; Shui, Ying-Bo; Siegfried, Carla J; Holekamp, Nancy M; Bai, Fang
2014-05-01
Oxygen levels in the eye are generally low and tightly regulated. Oxygen enters the eye largely by diffusion from retinal arterioles and through the cornea. In intact eyes, oxygen from the retinal arterioles diffuses into the vitreous body. There is a decreasing oxygen gradient from the retina to the lens, established by oxygen consumption by ascorbate in the vitreous fluid and lens metabolism. Age-related degeneration of the vitreous body or removal during vitrectomy exposes the posterior of the lens to increased oxygen, causing nuclear sclerotic cataracts. Lowering oxygen in the vitreous, as occurs in patients with ischemic diabetic retinopathy, protects against cataracts after vitrectomy. Vitrectomy and cataract surgery increase oxygen levels at the trabecular meshwork and with it the risk of open angle glaucoma. Two additional risk factors for glaucoma, African heritage and having a thinner cornea, are also associated with increased oxygen in the anterior chamber angle. Preservation of the vitreous body and the lens, two important oxygen consumers, would protect against nuclear sclerotic cataracts and open angle glaucoma. Delaying removal of the lens for as long as possible after vitrectomy would be an important step in delaying ocular hypertension and glaucoma progression.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Okumura, Satoshi; Komori, Masataka
We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types ofmore » gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of {sup 18}F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.« less
Spatial range of illusory effects in Müller-Lyer figures.
Predebon, J
2001-11-01
The spatial range of the illusory effects in Müller-Lyer (M-L) figures was examined in three experiments. Experiments 1 and 2 assessed the pattern of bisection errors along the shaft of the standard or double-angle (experiment 1) and the single-angle (experiment 2) M-L figures: Subjects bisected the shaft and the resulting two half-segments of the shaft to produce apparently equal quarters, and then each of the quarters to produce eight equal-appearing segments. The bisection judgments of each segment were referenced to the segment's physical midpoints. The expansion or wings-out and the contraction or wings-in figures yielded similar patterns of bisection errors. For the standard M-L figures, there were significant errors in bisecting each half, and each end-quarter, but not the two central quarters of the shaft. For the single-angle M-L figures, there were significant errors in bisecting the length of the shaft, the half-segment, and the quarter, of the shaft adjacent to the vertex but not the second quarter from the vertex nor in dividing the half of the shaft at the open end of the figure into four equal intervals. Experiment 3 assessed the apparent length of the half-segment of the shaft at the open end of the single-angle figures. Length judgments were unaffected by the vertex at the opposite end of the shaft. Taken together, the results indicate that the length distortions in both the standard and single-angle M-L figures are not uniformly distributed along the shaft but rather are confined mainly to the quarters adjacent to the vertices. The present findings imply that theories of the M-L illusion which assume uniform expansion or contraction of the shafts are incomplete.
Masuda, S; Furumatsu, T; Okazaki, Y; Kodama, Y; Hino, T; Kamatsuki, Y; Miyazawa, S; Ozaki, T
2018-04-10
A medial meniscus posterior root tear (MMPRT) is defined as an injury to the posterior meniscal insertion on the tibia. In MMPRT, the medial meniscus (MM) hoop function is damaged, and the MM undergoes a medial extrusion into the interior from the superior articular surface of the tibia. However, the details of MM position and movement during knee joint movement are unclear in MMPRT cases. The present study aims to evaluate MM position and movement via magnetic resonance imaging (MRI) examination of the MM posterior extrusion (MMPE) at knee flexion angles of 10° and 90°. We hypothesized that, during knee flexion, the MM will shift to the posterior and the posterior extrusion will increase compared to that when the knee is extended. Twenty-four patients were diagnosed with symptomatic MMPRT on open MRI examination. Preoperative MMPE, anteroposterior interval (API) of the MM, and MM medial extrusion (MMME) at knee flexion angles of 10° and 90° were measured. For patients with MMPRT, the MMPE increased from -4.77±1.43mm to 3.79±1.17mm (p<0.001) when the knee flexion angle increased from 10° to 90°. Further, flexing the knee from 10° to 90° decreased the API of the MM from 20.19±4.22mm to 16.41±5.14mm (p<0.001). MMME showed no significant change between knee flexion angles of 10° and 90°. This study demonstrated that, in cases of MMPRT, the MMPE clearly increases when the knee is flexed to 90°, while MMME does not change. Our results suggest that open MRI examination can be used to evaluate the dynamic position of the posterior MM by scanning the knee as it flexes to 90°. IV: retrospective cohort study. Copyright © 2018 Elsevier Masson SAS. All rights reserved.
Initial experience with purely laparoscopic living-donor right hepatectomy.
Hong, S K; Lee, K W; Choi, Y; Kim, H S; Ahn, S W; Yoon, K C; Kim, H; Yi, N J; Suh, K S
2018-05-01
There may be concerns about purely laparoscopic donor right hepatectomy (PLDRH) compared with open donor right hepatectomy, especially when performed by surgeons accustomed to open surgery. This study aimed to describe technical tips and pitfalls in PLDRH. Data from donors who underwent PLDRH at Seoul National University Hospital between December 2015 and July 2017 were analysed retrospectively. Endpoints analysed included intraoperative events and postoperative complications. All operations were performed by a single surgeon with considerable experience in open living donor hepatectomy. A total of 26 donors underwent purely laparoscopic right hepatectomy in the study interval. No donor required transfusion during surgery, whereas two underwent reoperation. In two donors, the dissection plane at the right upper deep portion of the midplane was not correct. One donor experienced portal vein injury during caudate lobe transection, and one developed remnant left hepatic duct stenosis. One donor experienced remnant portal vein angulation owing to a different approach angle, and one experienced arterial damage associated with the use of a laparoscopic energy device. One donor had postoperative bleeding due to masking of potential bleeding foci owing to intra-abdominal pressure during laparoscopy. Two donors experienced right liver surface damage caused by a xiphoid trocar. Purely laparoscopic donor hepatectomy differs from open donor hepatectomy in terms of angle and caudal view. Therefore, surgeons experienced in open donor hepatectomy must gain adequate experience in laparoscopic liver surgery and make adjustments when performing PLDRH. © 2018 BJS Society Ltd Published by John Wiley & Sons Ltd.
Generalized Brewster effect in dielectric metasurfaces
Paniagua-Domínguez, Ramón; Yu, Ye Feng; Miroshnichenko, Andrey E.; Krivitsky, Leonid A.; Fu, Yuan Hsing; Valuckas, Vytautas; Gonzaga, Leonard; Toh, Yeow Teck; Kay, Anthony Yew Seng; Luk'yanchuk, Boris; Kuznetsov, Arseniy I.
2016-01-01
Polarization is a key property defining the state of light. It was discovered by Brewster, while studying light reflected from materials at different angles. This led to the first polarizers, based on Brewster's effect. Now, one of the trends in photonics is the study of miniaturized devices exhibiting similar, or improved, functionalities compared with bulk optical elements. In this work, it is theoretically predicted that a properly designed all-dielectric metasurface exhibits a generalized Brewster's effect potentially for any angle, wavelength and polarization of choice. The effect is experimentally demonstrated for an array of silicon nanodisks at visible wavelengths. The underlying physics is related to the suppressed scattering at certain angles due to the interference between the electric and magnetic dipole resonances excited in the nanoparticles. These findings open doors for Brewster phenomenon to new applications in photonics, which are not bonded to a specific polarization or angle of incidence. PMID:26783075
NASA Astrophysics Data System (ADS)
Kataria, Devika; Krishnamoorthy, Kothandam; Iyer, S. Sundar Kumar
2017-08-01
Tuning metal nanoparticle (MNP) contact angle on the surface it is formed can help maximise the useful optical coupling in photovoltaic films by localized surface plasmon (LSP) resonance—opening up the possibility of building improved photovoltaic cells. In this work experimental demonstration of optical absorption increase in copper phthalocyanine (CuPc) films by tuning silver MNP shape by changing its contact angles with substrate has been reported. Thin films of poly3,4 ethylenedioxythiophene: sodium dodecycl sulphate (PEDOT:SDS) with different surface energies were formed on indium tin oxide (ITO) coated glass by electro-deposition. Silver MNPs thermally evaporated directly on ozonised ITO as well as on the PEDOT:SDS films showed contact angles ranging from 60° to 125°. The CuPc layer was deposited on top of the MNPs. For the samples studied, best optical absorption in the CuPc layer was for a contact angle of 110°.
Optimal operation of turbo blowers serially connected using inlet vanes
NASA Astrophysics Data System (ADS)
Jang, Choon-Man
2011-03-01
Optimal operation of the turbo blowers having an inlet vane has been studied to understand the blowers' operating performance. To analyze three-dimensional flow field in the turbo blowers serially connected, general analysis code, CFX, is introduced in the present work. SST turbulence model is employed to estimate the eddy viscosity. Throughout the numerical analysis, it is found that the flow rates of the turbo blowers can be controlled at the vane angle between 90 (full open condition) degrees and 60 degrees effectively, because pressure loss rapidly increases below 60 degree of a vane angle. Efficiency also has almost the same values from 90 degrees to 60 degrees of a vane angle. It is noted that the distorted inlet velocity generated in the small vane angle makes performance deterioration of the turbo blowers due to the local leading edge separation and the following non-uniform blade loading.
DOE Office of Scientific and Technical Information (OSTI.GOV)
García-Cervantes, H.; Sotolongo-Costa, O.; Gaggero-Sager, L. M.
Graphene Superlattices (GSs) have attracted a lot of attention due to its peculiar properties as well as its possible technological implications. Among these characteristics we can mention: the extra Dirac points in the dispersion relation and the highly anisotropic propagation of the charge carriers. However, despite the intense research that is carried out in GSs, so far there is no report about the angular dependence of the Transmission Gap (TG) in GSs. Here, we report the dependence of TG as a function of the angle of the incident Dirac electrons in a rather simple Electrostatic GS (EGS). Our results showmore » that the angular dependence of the TG is intricate, since for moderated angles the dependence is parabolic, while for large angles an exponential dependence is registered. We also find that the TG can be modulated from meV to eV, by changing the structural parameters of the GS. These characteristics open the possibility for an angle-dependent bandgap engineering in graphene.« less
75 FR 69737 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-15
... moving violations in a CMV. Michael E. Herrera, Jr., Mr. Herrera, 53, has had primary open angle glaucoma... opinion. Mr. Herrera has sufficient vision to drive a commercial vehicle. Mr. Herrera reported that he has...
Bend losses in rectangular culverts.
DOT National Transportation Integrated Search
2008-09-01
This study investigated bend losses for open channel flow in rectangular channels or culverts. Laboratory experiments were performed for sub-critical flow in rectangular channels with abrupt bends. Bend angles of approximately 30, 45, 60, 75 and 90 d...
Dickson, Richard K.
2010-09-07
A quick insert and release laser beam guard panel clamping apparatus having a base plate mountable on an optical table, a first jaw affixed to the base plate, and a spring-loaded second jaw slidably carried by the base plate to exert a clamping force. The first and second jaws each having a face acutely angled relative to the other face to form a V-shaped, open channel mouth, which enables wedge-action jaw separation by and subsequent clamping of a laser beam guard panel inserted through the open channel mouth. Preferably, the clamping apparatus also includes a support structure having an open slot aperture which is positioned over and parallel with the open channel mouth.
Micromechanical torsional digital-to-analog converter for open-loop angular positioning applications
NASA Astrophysics Data System (ADS)
Zhou, Guangya; Tay, Francis E. H.; Chau, Fook Siong; Zhao, Yi; Logeeswaran, VJ
2004-05-01
This paper reports a novel micromechanical torsional digital-to-analog converter (MTDAC), operated in open-loop with digitally controlled precise multi-level tilt angles. The MTDAC mechanism presented is analogous to that of an electrical binary-weighted-input digital-to-analog converter (DAC). It consists of a rigid tunable platform, an array of torsional microactuators, each operating in a two-state (on/off) mode, and a set of connection beams with binary-weighted torsional stiffnesses that connect the actuators to the platform. The feasibility of the proposed MTDAC mechanism was verified numerically by finite element simulations and experimentally with a commercial optical phase-shifting interferometric system. A prototype 2-bit MTDAC was implemented using the poly-MUMPS process achieving a full-scale output tilt angle of 1.92° with a rotation step of 0.64°. This mechanism can be configured for many promising applications, particularly in beam steering-based OXC switches.
Multifocal visual evoked potentials for early glaucoma detection.
Weizer, Jennifer S; Musch, David C; Niziol, Leslie M; Khan, Naheed W
2012-07-01
To compare multifocal visual evoked potentials (mfVEP) with other detection methods in early open-angle glaucoma. Ten patients with suspected glaucoma and 5 with early open-angle glaucoma underwent mfVEP, standard automated perimetry (SAP), short-wave automated perimetry, frequency-doubling technology perimetry, and nerve fiber layer optical coherence tomography. Nineteen healthy control subjects underwent mfVEP and SAP for comparison. Comparisons between groups involving continuous variables were made using independent t tests; for categorical variables, Fisher's exact test was used. Monocular mfVEP cluster defects were associated with an increased SAP pattern standard deviation (P = .0195). Visual fields that showed interocular mfVEP cluster defects were more likely to also show superior quadrant nerve fiber layer thinning by OCT (P = .0152). Multifocal visual evoked potential cluster defects are associated with a functional and an anatomic measure that both relate to glaucomatous optic neuropathy. Copyright 2012, SLACK Incorporated.
EX-PRESS Glaucoma Filtration Device: efficacy, safety, and predictability
Chan, Jessica E; Netland, Peter A
2015-01-01
Trabeculectomy has been the traditional primary surgical therapy for open-angle glaucoma. While trabeculectomy is effective in lowering intraocular pressure, complications associated with the procedure have motivated the development of alternative techniques and devices, including the EX-PRESS Glaucoma Filtration Device. This review describes the efficacy, safety, complication rates, and potential advantages and disadvantages of the EX-PRESS Glaucoma Filtration Device. EX-PRESS implantation is technically simpler compared with that of trabeculectomy, with fewer surgical steps. Vision recovery has been more rapid after EX-PRESS implantation compared with trabeculectomy. Intraocular pressure variation is lower during the early postoperative period, indicating a more predictable procedure. While efficacy of the EX-PRESS implant has been comparable to trabeculectomy, postoperative complications appear less common after EX-PRESS implantation compared with trabeculectomy. The EX-PRESS Glaucoma Filtration Device appears to be safe and effective in the surgical management of open-angle glaucoma. PMID:26366105
Common variants near CAV1 and CAV2 are associated with primary open-angle glaucoma
Thorleifsson, Gudmar; Walters, G Bragi; Hewitt, Alex W; Masson, Gisli; Helgason, Agnar; DeWan, Andrew; Sigurdsson, Asgeir; Jonasdottir, Adalbjorg; Gudjonsson, Sigurjon A; Magnusson, Kristinn P; Stefansson, Hreinn; Lam, Dennis S C; Tam, Pancy O S; Gudmundsdottir, Gudrun J; Southgate, Laura; Burdon, Kathryn P; Gottfredsdottir, Maria Soffia; Aldred, Micheala A; Mitchell, Paul; St Clair, David; Collier, David A; Tang, Nelson; Sveinsson, Orn; Macgregor, Stuart; Martin, Nicholas G; Cree, Angela J; Gibson, Jane; MacLeod, Alex; Jacob, Aby; Ennis, Sarah; Young, Terri L; Chan, Juliana C N; Karwatowski, Wojciech S S; Hammond, Christopher J; Thordarson, Kristjan; Zhang, Mingzhi; Wadelius, Claes; Lotery, Andrew J; Trembath, Richard C; Pang, Chi Pui; Hoh, Josephine; Craig, Jamie E; Kong, Augustine; Mackey, David A; Jonasson, Fridbert; Thorsteinsdottir, Unnur; Stefansson, Kari
2011-01-01
We conducted a genome-wide association study for primary open-angle glaucoma (POAG) in 1,263 affected individuals (cases) and 34,877 controls from Iceland. We identified a common sequence variant at 7q31 (rs4236601[A], odds ratio (OR) = 1.36, P = 5.0 × 10-10). We then replicated the association in sample sets of 2,175 POAG cases and 2,064 controls from Sweden, the UK and Australia (combined OR = 1.18, P = 0.0015) and in 299 POAG cases and 580 unaffected controls from Hong Kong and Shantou, China (combined OR = 5.42, P = 0.0021). The risk variant identified here is located close to CAV1 and CAV2, both of which are expressed in the trabecular meshwork and retinal ganglion cells that are involved in the pathogenesis of POAG. PMID:20835238
Nguyen, Dorothy; Vedamurthy, Indu; Schor, Clifton
2008-03-01
Accommodation and convergence systems are cross-coupled so that stimulation of one system produces responses by both systems. Ideally, the cross-coupled responses of accommodation and convergence match their respective stimuli. When expressed in diopters and meter angles, respectively, stimuli for accommodation and convergence are equal in the mid-sagittal plane when viewed with symmetrical convergence, where historically, the gains of the cross coupling (AC/A and CA/C ratios) have been quantified. However, targets at non-zero azimuth angles, when viewed with asymmetric convergence, present unequal stimuli for accommodation and convergence. Are the cross-links between the two systems calibrated to compensate for stimulus mismatches that increase with gaze-azimuth? We measured the response AC/A and stimulus CA/C ratios at zero azimuth, 17.5 and 30 deg of rightward gaze eccentricities with a Badal Optometer and Wheatstone-mirror haploscope. AC/A ratios were measured under open-loop convergence conditions along the iso-accommodation circle (locus of points that stimulate approximately equal amounts of accommodation to the two eyes at all azimuth angles). CA/C ratios were measured under open-loop accommodation conditions along the iso-vergence circle (locus of points that stimulate constant convergence at all azimuth angles). Our results show that the gain of accommodative-convergence (AC/A ratio) decreased and the bias of convergence-accommodation increased at the 30 deg gaze eccentricity. These changes are in directions that compensate for stimulus mismatches caused by spatial-viewing geometry during asymmetric convergence.
3D DEM analyses of the 1963 Vajont rock slide
NASA Astrophysics Data System (ADS)
Boon, Chia Weng; Houlsby, Guy; Utili, Stefano
2013-04-01
The 1963 Vajont rock slide has been modelled using the distinct element method (DEM). The open-source DEM code, YADE (Kozicki & Donzé, 2008), was used together with the contact detection algorithm proposed by Boon et al. (2012). The critical sliding friction angle at the slide surface was sought using a strength reduction approach. A shear-softening contact model was used to model the shear resistance of the clayey layer at the slide surface. The results suggest that the critical sliding friction angle can be conservative if stability analyses are calculated based on the peak friction angles. The water table was assumed to be horizontal and the pore pressure at the clay layer was assumed to be hydrostatic. The influence of reservoir filling was marginal, increasing the sliding friction angle by only 1.6˚. The results of the DEM calculations were found to be sensitive to the orientations of the bedding planes and cross-joints. Finally, the failure mechanism was investigated and arching was found to be present at the bend of the chair-shaped slope. References Boon C.W., Houlsby G.T., Utili S. (2012). A new algorithm for contact detection between convex polygonal and polyhedral particles in the discrete element method. Computers and Geotechnics, vol 44, 73-82, doi.org/10.1016/j.compgeo.2012.03.012. Kozicki, J., & Donzé, F. V. (2008). A new open-source software developed for numerical simulations using discrete modeling methods. Computer Methods in Applied Mechanics and Engineering, 197(49-50), 4429-4443.
Slow relaxation in weakly open rational polygons.
Kokshenev, Valery B; Vicentini, Eduardo
2003-07-01
The interplay between the regular (piecewise-linear) and irregular (vertex-angle) boundary effects in nonintegrable rational polygonal billiards (of m equal sides) is discussed. Decay dynamics in polygons (of perimeter P(m) and small opening Delta) is analyzed through the late-time survival probability S(m) approximately equal t(-delta). Two distinct slow relaxation channels are established. The primary universal channel exhibits relaxation of regular sliding orbits, with delta=1. The secondary channel is given by delta>1 and becomes open when m>P(m)/Delta. It originates from vertex order-disorder dual effects and is due to relaxation of chaoticlike excitations.
Surgical Orthodontic Treatment for Open Bite in Noonan Syndrome Patient: A Case Report.
Kawakami, Masayoshi; Yamamoto, Kazuhiko; Shimomura, Tadahiro; Kirita, Tadaaki
2016-03-01
Noonan syndrome, characterized by short stature, facial anomalies, and congenital heart defects, may also be associated with hematopoietic disorders. Craniofacial anomalies in affected patients include hypertelorism and severe open bite associated with masticatory dysfunction. We treated a Noonan syndrome patient with a skeletal open bite. Surgical orthodontic treatment including two-jaw surgery established a good occlusal relationship after correction of severe anemia. Both upper and lower incisors were moved to upright positions, while clockwise rotation of the palatal plane and decreased mandibular plane angle were accomplished. Lower masticatory activity may affect posttreatment occlusion in such cases.
Acoustic Shielding for a Model Scale Counter-rotation Open Rotor
NASA Technical Reports Server (NTRS)
Stephens, David B.; Edmane, Envia
2012-01-01
The noise shielding benefit of installing an open rotor above a simplified wing or tail is explored experimentally. The test results provide both a benchmark data set for validating shielding prediction tools and an opportunity for a system level evaluation of the noise reduction potential of propulsion noise shielding by an airframe component. A short barrier near the open rotor was found to provide up to 8.5 dB of attenuation at some directivity angles, with tonal sound particularly well shielded. Predictions from two simple shielding theories were found to overestimate the shielding benefit.
Groh, Edward F.; Cassidy, Dale A.
1978-01-01
A thermocouple lead or other small diameter wire, cable or tube is passed through a thin material such as sheet metal and sealed thereinto by drawing complementary longitudinally angled, laterally rounded grooves terminating at their base ends in a common plane in both sides of the thin material with shearing occuring at the deep end faces thereof to form a rounded opening in the thin material substantially perpendicular to the plane of the thin material, passing a thermocouple lead or similar object through the opening so formed and sealing the opening with a sealant which simultaneously bonds the lead to the thin material.
NASA Astrophysics Data System (ADS)
Kettermann, M.; van Gent, H. W.; Urai, J. L.
2012-04-01
Brittle rocks, such as for example those hosting many carbonate or sandstone reservoirs, are often affected by different kinds of fractures that influence each other. Understanding the effects of these interactions on fault geometries and the formation of cavities and potential fluid pathways might be useful for reservoir quality prediction and production. Analogue modeling has proven to be a useful tool to study faulting processes, although usually the used materials do not provide cohesion and tensile strength, which are essential to create open fractures. Therefore, very fine-grained, cohesive, hemihydrate powder was used for our experiments. The mechanical properties of the material are scaling well for natural prototypes. Due to the fine grain size structures are preserved in in great detail. The used deformation box allows the formation of a half-graben and has initial dimensions of 30 cm width, 28 cm length and 20 cm height. The maximum dip-slip along the 60° dipping predefined basement fault is 4.5 cm and was fully used in all experiments. To setup open joints prior to faulting, sheets of paper placed vertically within the box to a depth of about 5 cm from top. The powder was then sieved into the box, embedding the paper almost entirely. Finally strings were used to remove the paper carefully, leaving open voids. Using this method allows the creation of cohesionless open joints while ensuring a minimum impact on the sensitive surrounding material. The presented series of experiments aims to investigate the effect of different angles between the strike of a rigid basement fault and a distinct joint set. All experiments were performed with a joint spacing of 2.5 cm and the fault-joint angles incrementally covered 0°, 4°, 8°, 12°, 16°, 20° and 25°. During the deformation time lapse photography from the top and side captured every structural change and provided data for post-processing analysis using particle imaging velocimetry (PIV). Additionally, stereo-photography at the final stage of deformation enabled the creation of 3D models to preserve basic geometric information. The models showed that at the surface the deformation localized always along preexisting joints, even when they strike at an angle to the basement-fault. In most cases faults intersect precisely at the maximum depth of the joints. With increasing fault-joint angle the deformation occurred distributed over several joints by forming stepovers with fractures oriented normal to the strike of the joints. No fractures were observed parallel to the basement fault. At low angles stepovers coincided with wedge-shaped structures between two joints that remain higher than the surrounding joint-fault intersection. The wide opening gap along the main fault allowed detailed observations of the fault planes at depth, which revealed (1) changing dips according to joint-fault angles, (2) slickenlines, (3) superimposed steepening fault-planes, causing sharp sawtooth-shaped structures. Comparison to a field analogue at Canyonlands National Park, Utah/USA showed similar structures and features such as vertical fault escarpments at the surface coinciding with joint-surfaces. In the field and in the models stepovers were observed as well as conjugate faulting and incremental fault-steepening.
Combining electromagnetic gyro-kinetic particle-in-cell simulations with collisions
NASA Astrophysics Data System (ADS)
Slaby, Christoph; Kleiber, Ralf; Könies, Axel
2017-09-01
It has been an open question whether for electromagnetic gyro-kinetic particle-in-cell (PIC) simulations pitch-angle collisions and the recently introduced pullback transformation scheme (Mishchenko et al., 2014; Kleiber et al., 2016) are consistent. This question is positively answered by comparing the PIC code EUTERPE with an approach based on an expansion of the perturbed distribution function in eigenfunctions of the pitch-angle collision operator (Legendre polynomials) to solve the electromagnetic drift-kinetic equation with collisions in slab geometry. It is shown how both approaches yield the same results for the frequency and damping rate of a kinetic Alfvén wave and how the perturbed distribution function is substantially changed by the presence of pitch-angle collisions.
NASA Astrophysics Data System (ADS)
Lin, Chia-Hung; Uchiyama, Shota; Maruyama, Takahiro; Naritsuka, Shigeya
2012-04-01
Low-angle-incidence microchannel epitaxy (LAIMCE) of a-plane GaN was performed using ammonia-based metal-organic molecular beam epitaxy to obtain wide and thin lateral overgrowth over a SiO2 mask. Trimethylgallium (TMG) was supplied perpendicular to the openings cut in the mask with a low incident angle of 5° relative to the substrate plane. The [NH3]/[TMG] ratio (R) dependence of GaN LAIMCE was optimized by varying R from 5 to 30. A wide lateral overgrowth of 3.7 µm with a dislocation density below the transmission electron microscope detection limit was obtained at R=15 for a thickness of 520 nm.
NASA Technical Reports Server (NTRS)
Morelli, Eugene A.
1995-01-01
Flight test maneuvers are specified for the F-18 High Alpha Research Vehicle (HARV). The maneuvers were designed for open loop parameter identification purposes, specifically for optimal input design validation at 5 degrees angle of attack, identification of individual strake effectiveness at 40 and 50 degrees angle of attack, and study of lateral dynamics and lateral control effectiveness at 40 and 50 degrees angle of attack. Each maneuver is to be realized by applying square wave inputs to specific control effectors using the On-Board Excitation System (OBES). Maneuver descriptions and complete specifications of the time/amplitude points define each input are included, along with plots of the input time histories.
Wasyluk, Jaromir T; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-03-01
We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18-70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices. Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.
Caffarra, Paolo; Gardini, Simona; Dieci, Francesca; Copelli, Sandra; Maset, Laura; Concari, Letizia; Farina, Elisabetta; Grossi, Enzo
2013-01-01
The differential diagnosis across different variants of degenerative diseases is sometimes controversial. This study aimed to validate a qualitative scoring method for the pentagons copy test (QSPT) of Mini-Mental State Examination (MMSE) based on the assessment of different parameters of the pentagons drawing, such as number of angles, distance/intersection, closure/opening, rotation, closing-in, and to verify its efficacy to differentiate dementia with Lewy Body (DLB) from Alzheimer's disease (AD). We established the reliability of the qualitative scoring method through the inter-raters and intra-subjects analysis. QSPT was then applied to forty-six AD and forty-six DLB patients, using two phases statistical approach, standard and artificial neural network respectively. DLB patients had significant lower total score in the copy of pentagons and number of angles, distance/intersection, closure/opening, rotation compared to AD. However the logistic regression did not allow to establish any suitable modeling, whereas using Auto-Contractive Map (Auto-CM) the DLB was more strongly associated with low scores in some qualitative parameters of pentagon copying, i.e. number of angles and opening/closure and, for the remaining subitems of the MMSE, in naming, repetition and written comprehension, and for demographic variables of gender (male) and education (6-13 years). Twist system modeling showed that the QSPT had a good sensitivity (70.29%) and specificity (78.67%) (ROC-AUC 0.74). The proposed qualitative method of assessment of pentagons copying used in combination with non-linear analysis, showed to be consistent and effective in the differential diagnosis between Lewy Body and Alzheimer's dementia.
NASA Astrophysics Data System (ADS)
Bisdom, Kevin; Bertotti, Giovanni; Nick, Hamidreza M.
2016-10-01
Aperture has a controlling impact on porosity and permeability and is a source of uncertainty in modeling of naturally fractured reservoirs. This uncertainty results from difficulties in accurately quantifying aperture in the subsurface and from a limited fundamental understanding of the mechanical and diagenetic processes that control aperture. In the absence of cement bridges and high pore pressure, fractures in the subsurface are generally considered to be closed. However, experimental work, outcrop analyses and subsurface data show that some fractures remain open, and that aperture varies even along a single fracture. However, most fracture flow models consider constant apertures for fractures. We create a stress-dependent heterogeneous aperture by combining Finite Element modeling of discrete fracture networks with an empirical aperture model. Using a modeling approach that considers fractures explicitly, we quantify equivalent permeability, i.e. combined matrix and stress-dependent fracture flow. Fracture networks extracted from a large outcropping pavement form the basis of these models. The results show that the angle between fracture strike and σ1 has a controlling impact on aperture and permeability, where hydraulic opening is maximum for an angle of 15°. At this angle, the fracture experiences a minor amount of shear displacement that allows the fracture to remain open even when fluid pressure is lower than the local normal stress. Averaging the heterogeneous aperture to scale up permeability probably results in an underestimation of flow, indicating the need to incorporate full aperture distributions rather than simplified aperture models in reservoir-scale flow models.
Takeuchi, Ryohei; Woon-Hwa, Jung; Ishikawa, Hiroyuki; Yamaguchi, Yuichiro; Osawa, Katsunari; Akamatsu, Yasushi; Kuroda, Koichi
2017-12-01
The purpose of this study was to compare the mechanical fixation strengths of anteromedial and medial plate positions in osteotomy, and clarify the effects of bone substitute placement into the osteotomy site. Twenty-eight sawbone tibia models were used. Four different models were prepared: Group A, the osteotomy site was open and the plate position was anteromedial; Group B, bone substitutes were inserted into the osteotomy site and the plate position was anteromedial; Group C, the osteotomy site was open and the plate position was medial; and Group D, bone substitutes were inserted into the osteotomy site and the plate position was medial. The loading condition ranged from 0 to 800N and one hertz cycles were applied. Changes of the tibial posterior slope angle (TPS), stress on the plate and lateral hinge were measured. The changes in the TPS and the stress on the plate were significantly larger in Group A than in Group C. These were significantly larger in Group A than in Group B, and in Group C than in Group D. There was no significant difference between Group B and Group D, and no significant difference between knee flexion angles of 0° and 10°. Stress on the lateral hinge was significantly smaller when bone substitute was used. A medial plate position was biomechanically superior to an anteromedial position if bone substitute was not used. Bone substitute distributed the stress concentration around the osteotomy gap and prevented an increase in TPS angle regardless of the plate position. Copyright © 2017. Published by Elsevier B.V.
Reproducibility of intraocular pressure peak and fluctuation of the water-drinking test.
Hatanaka, Marcelo; Alencar, Luciana M; De Moraes, Carlos G; Susanna, Remo
2013-01-01
The water-drinking test has been used as a stress test to evaluate the drainage system of the eye. However, in order to be clinically applicable,a test must provide reproducible results with consistent measurements. This study was performed to verify the reproducibility of intraocular pressure peaks and fluctuation detected during the water-drinking test in patients with ocular hypertension and open-angle glaucoma. A prospective analysis of patients in a tertiary care unit for glaucoma treatment. Twenty-four ocular hypertension and 64 open-angle glaucoma patients not under treatment. The water-drinking test was performed in 2 consecutive days by the same examiners in patients not under treatment. Reproducibility was assessed using the intraclass correlation coefficient. Peak and fluctuation of intraocular pressure obtained with the water-drinking test were analysed for reproducibility. Eighty-eight eyes from 24 ocular hypertension and 64 open-angle glaucoma patients not under treatment were evaluated. Test and retest intraocular pressure peak values were 28.38 ± 4.64 and 28.38 ± 4.56 mmHg, respectively (P = 1.00). Test and retest intraocular pressure fluctuation values were 5.75 ± 3.9 and 4.99 ± 2.7 mmHg, respectively (P = 0.06). Based on intraclass coefficient, reproducibility was excellent for peak intraocular pressure (intraclass correlation coefficient = 0.79) and fair for intraocular pressure fluctuation (intraclass correlation coefficient = 0.37). Intraocular pressure peaks detected during the water-drinking test presented excellent reproducibility, whereas the reproducibility of fluctuation was considered fair. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.
Transcorneal Electrical Stimulation Therapy for Retinal Disease
2012-05-03
Retinitis Pigmentosa; Macula Off; Primary Open Angle Glaucoma; Hereditary Macular Degeneration; Treated Retina Detachment; Retinal Artery Occlusion; Retinal Vein Occlusion; Non-Arthritic-Anterior-Ischemic Optic-Neuropathy; Hereditary Autosomal Dominant Optic Atrophy; Dry Age Related Macular Degeneration; Ischemic Macula Edema
Kinematics of reflections in subsurface offset and angle-domain image gathers
NASA Astrophysics Data System (ADS)
Dafni, Raanan; Symes, William W.
2018-05-01
Seismic migration in the angle-domain generates multiple images of the earth's interior in which reflection takes place at different scattering-angles. Mechanically, the angle-dependent reflection is restricted to happen instantaneously and at a fixed point in space: Incident wave hits a discontinuity in the subsurface media and instantly generates a scattered wave at the same common point of interaction. Alternatively, the angle-domain image may be associated with space-shift (regarded as subsurface offset) extended migration that artificially splits the reflection geometry. Meaning that, incident and scattered waves interact at some offset distance. The geometric differences between the two approaches amount to a contradictory angle-domain behaviour, and unlike kinematic description. We present a phase space depiction of migration methods extended by the peculiar subsurface offset split and stress its profound dissimilarity. In spite of being in radical contradiction with the general physics, the subsurface offset reveals a link to some valuable angle-domain quantities, via post-migration transformations. The angle quantities are indicated by the direction normal to the subsurface offset extended image. They specifically define the local dip and scattering angles if the velocity at the split reflection coordinates is the same for incident and scattered wave pairs. Otherwise, the reflector normal is not a bisector of the opening angle, but of the corresponding slowness vectors. This evidence, together with the distinguished geometry configuration, fundamentally differentiates the angle-domain decomposition based on the subsurface offset split from the conventional decomposition at a common reflection point. An asymptotic simulation of angle-domain moveout curves in layered media exposes the notion of split versus common reflection point geometry. Traveltime inversion methods that involve the subsurface offset extended migration must accommodate the split geometry in the inversion scheme for a robust and successful convergence at the optimal velocity model.
Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan
2013-11-21
To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40-80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese.
Wang, Ye Elaine; Li, Yingjie; Wang, Dandan; He, Mingguang; Lin, Shan
2013-01-01
Purpose. To determine if factors associated with gonioscopy-determined occludable angle among American Caucasians are similar to those found in ethnic Chinese. Methods. This is a prospective cross-sectional study with 120 American Caucasian, 116 American Chinese, and 116 mainland Chinese subjects. All three groups were matched for sex and age (40–80 years). Gonioscopy was performed for each subject (occludable angles = posterior trabecular meshwork not visible for ≥2 quadrants). Anterior segment optical coherence tomography and customized software was used to measure anterior segment biometry and iris parameters, including anterior chamber depth/width (ACD, ACW), lens vault (LV), and iris thickness/area/curvature. Results. In both Chinese and Caucasians, eyes with occludable angles had smaller ACD and ACW, and larger LV and iris curvature than eyes with open angles (all P < 0.005). Chinese eyes had smaller ACD and ACW than Caucasian eyes (both P < 0.01) in the occludable angle cohort. Iris characteristics did not differ significantly between Chinese and Caucasians in the occludable angle cohort. Based on multivariate logistic regression, gonioscopy-determined occludable angle was significantly associated with LV, iris area, and sex (all P < 0.03) in Chinese; and with LV, ACD, iris thickness, age, and sex (all P < 0.04) in Caucasians. Conclusions. Several factors associated with occludable angle differed between Caucasians and Chinese, suggesting potentially different mechanisms in occludable angle development in the two racial groups. This is the first study to demonstrate that lens vault is an important anterior segment optical coherence tomography parameter in the screening for angle closure in Caucasians. In addition, iris thickness was a significant predictor for occludable angles in Caucasians but was not in ethnic Chinese. PMID:24168992
Passive Capture Joint with Three Degrees of Freedom
NASA Technical Reports Server (NTRS)
Cloyd, Richard A. (Inventor); Weddendorf, Bruce (Inventor)
2001-01-01
A passive capture joint with three degrees of freedom is presented wherein two structural elements are joined together solely by moving the two elements into position, and which when joined together have rotation in all three axes. The inventive apparatus is comprised of two halves: (1) a joint ball mounted on a stem as in a common trailer hitch, and; (2) a socket. The socket consists of a base having an exterior wall and forming an interior chamber, the chamber having a top end and a bottom end, and an interior wall. The chamber is open at the top end, and forms a spherical cup at the bottom end. The socket base's interior chamber is sized to accept the joint ball. The base also forms at least one bore at an acute angle away from the interior chamber's open end. The bores have a first opening in the interior wall of the chamber, and a second opening in the exterior wall of the base. Retaining balls sized to fit within the bores, but to only partially pass through the first opening, are moveably housed within the bores. The retaining balls are moveably held in the first opening by a compression spring housed in the bore. As the joint ball is inserted in the chamber it forces the retaining balls back into the bore until the equator of the joint ball passes. Because the bore is at an acute angle to the chamber the joint ball cannot exit the chamber without the joint being unlocked. The joint is unlocked by rotating a locking ring which encircles the base and covers the second opening. The locking ring has a radial slot for each retaining ball, disposed angularly from the base, and sized to allow passage of the retaining ball in the radial direction when the locking ring is rotated to align the radial slot with the second opening.
Development of a software package for solid-angle calculations using the Monte Carlo method
NASA Astrophysics Data System (ADS)
Zhang, Jie; Chen, Xiulian; Zhang, Changsheng; Li, Gang; Xu, Jiayun; Sun, Guangai
2014-02-01
Solid-angle calculations play an important role in the absolute calibration of radioactivity measurement systems and in the determination of the activity of radioactive sources, which are often complicated. In the present paper, a software package is developed to provide a convenient tool for solid-angle calculations in nuclear physics. The proposed software calculates solid angles using the Monte Carlo method, in which a new type of variance reduction technique was integrated. The package, developed under the environment of Microsoft Foundation Classes (MFC) in Microsoft Visual C++, has a graphical user interface, in which, the visualization function is integrated in conjunction with OpenGL. One advantage of the proposed software package is that it can calculate the solid angle subtended by a detector with different geometric shapes (e.g., cylinder, square prism, regular triangular prism or regular hexagonal prism) to a point, circular or cylindrical source without any difficulty. The results obtained from the proposed software package were compared with those obtained from previous studies and calculated using Geant4. It shows that the proposed software package can produce accurate solid-angle values with a greater computation speed than Geant4.
Tracing the Angular Dependence of the CGM
NASA Astrophysics Data System (ADS)
Nattinger, Michael; Christensen, Charlotte
2017-01-01
The circumgalactic media (CGM) is enriched with metals through a process called the baryon cycle, which may play a significant role in the regulation of star formation. While the relationship between the CGM’s baryonic makeup and impact parameter is well documented, the relationship between the baryonic distribution of the CGM and the azimuthal angle out of the plane of the galaxy remains an open question. We investigated the angular distribution of baryons in the CGM by creating mock-absorption line spectra for a high-resolution simulation of a Milky Way-like galaxy at redshift zero. By comparison with data from the Cosmic Origins Spectrograph-Halos survey, we determined that our equivalent widths of HI, MgII, CIII, SiII, and SiIII are consistent with observations. Using our data, we found that low ionization state material is more prevalent at low azimuthal angles and that high ionization state material is more prevalent at high angles within the virial radius. We attributed this increased ionization to higher temperatures at high angles. We also found that the highest metallicity levels appear at high and low azimuthal angles, with lower metallicities at middle angles. This evidence supports the recycled accretion model of CGM baryon flow.
NASA Astrophysics Data System (ADS)
Kong, Lingfeng; Zhang, Jinhui; Wang, Huiyuan; Ma, Shenglin; Li, Fang; Wang, Qing-Ming; Qin, Lifeng
2016-12-01
In this paper, a MEMS piezoelectric cantilevered vibration energy harvester based on c-axis tilted AlN thin film is investigated. Based on basic piezoelectric equations and static analysis of cantilever beam, the equations for generated energy (E) and open circuit voltage (Vo) were derived, and simulations were carried out to study the effects of geometry parameters and c-axis tilted angle. Results show that E and Vo of energy harvesters are greatly dependent on c-axis tilted angle and geometry parameters, while the coupling between c-axis tilted angle and geometry parameters is not strong. For a given structure size, E and Vo can be almost simultaneously improved by controlling c-axis tilted angle; compared with the case of normal c-axis angle, E with optimal c-axis tilted angle can be amplified by more than 3 times, and the Vo is amplified by about 2 times. E or Vo could be further improved by geometry parameters, while there is trade-off between them. These results can be used for the design and application of piezoelectric cantilevered vibration energy harvester.
Amelot, Aymeric; Trunet, Stephanie; Degos, Vincent; André, Olivier; Dionnet, Aurore; Cornu, Philippe; Hans, Stéphane; Chauvet, Dorian
2015-10-01
The role of transoral robotic surgery (TORS) in the skull base emerges and represents the natural progression toward miniinvasive resections in confined spaces. The accessibility of the sella via TORS has been recently described on fresh human cadavers. An anatomic study is mandatory to know if this approach would be feasible in the majority of patients regardless of their oral morphological features. From 30 skull base CT scans from patients who were asked to open their mouth as wide as they can, we measured specific dimensions of the oral cavity and the skull base, such as length of the palate, mouth opening and distance from the sella to the palate. All data were acquired on a sagittal midline plane and on a 25° rotation plane, which simulated the axis of the robotic instruments. Looking at the projection of the dental palatine line on the sella, we studied possible predictive factors of sellar accessibility and tried to bring objective data for surgical feasibility. We also proposed an angle α to study the working angle at the skull base. We observed that the maximal mouth opening was a good predictive factor of sellar accessibility by TORS (p < 0.05). The mouth aperture threshold value for a good sensitivity, over 80 %, was comparable to the mean value of mouth opening in our series, 38.9 and 39.4 mm respectively. Moreover, we showed a statistically significant increase of the working angle α at the skull base comparing the lateral access to the midline one (p < 0.05). This seemed to quantitatively demonstrate that the robotic arms placed at the labial commissure of the mouth can reach the sella. From these anatomical features and previous cadaveric dissections, we assume that TORS may be feasible on a majority of patients to remove pituitary adenomas.
Opening-wedge high tibial osteotomy with a locked low-profile plate: surgical technique.
Kolb, Werner; Guhlmann, Hanno; Windisch, Christoph; Koller, Heiko; Grützner, Paul; Kolb, Klaus
2010-09-01
High tibial osteotomy has been recognized as a beneficial treatment for osteoarthritis of the medial compartment of the knee. The purpose of this prospective study was to assess the short-term results of opening-wedge high tibial osteotomies with locked plate fixation. From September 2002 to November 2005, fifty-one consecutive medial opening-wedge high tibial osteotomies were performed. The mean age of the patients at the time of the index operation was forty-nine years. The preoperative and postoperative factors analyzed included the grade of arthritis of the tibiofemoral compartment (the Ahlbäck radiographic grade), the anatomic tibiofemoral angle, patellar height, the Hospital for Special Surgery rating system score, and the Lysholm and Gillquist knee score. Postoperatively, one superficial wound infection occurred. Fifty of the fifty-one osteotomies healed after an average period of 12.9 weeks (range, eight to sixteen weeks) without bone grafts. A nonunion developed in a sixty-two-year-old patient who was a cigarette smoker. The average postoperative tibiofemoral angle was 9° of valgus. Forty-nine patients were followed for a mean of fifty-two months. The average score on the Hospital for Special Surgery rating system was 86 points at the time of the most recent follow-up. The rating was excellent in twenty-eight patients (57%), good in twelve (24%), fair in four (8%), and poor in five (10%). The average score on the Lysholm and Gillquist knee-scoring scale was 83 points. According to these scores, the outcome was excellent in nine patients (18%), good in thirty-one (63%), fair in three (6%), and poor in six (12%). Four knees failed after an average of thirty-six months. Our results suggest that an opening-wedge high tibial osteotomy with locked plate fixation allows a correct valgus angle to be achieved with good short-term results.
Yang, Ming; Zhao, Qinpeng; Hao, Dingjun; Chang, Zhen; Liu, Shichang; Yin, Xinhua
2018-06-16
To compare the efficacy and safety of novel percutaneous minimally invasive pedicle screw fixation and traditional open surgery for thoracolumbar fractures without neurological deficit. Sixty adult patients with single thoracolumbar fracture between June 2014 and June 2016 were recruited in this study, randomly divided into open fixation group (group A) or minimally invasive percutaneous fixation group (group B). Clinical and surgical evaluation including surgery time, blood losses, radiation times, hospital stay, and complication were performed. The two groups of patients with pre-operative and last follow-up anterior height ratio of fracture vertebral, Cobb angle of fracture vertebral, and VAS score of back pain were compared. All patients completed valid follow-ups, with an average time period of 15.4 months (12-26 months). Group B achieved much better results in time of operation, intra-operative blood loss, and length of stay than group A (P < 0.05). Group A was significantly better than group B in the times of radiation (P < 0.05). The VAS score was significantly lower in group B than in group A at three days after the operation (P < 0.05). There were no significant differences between the two groups in the anterior height ratio of fracture vertebral, Cobb angle, and VAS score in the last follow-up (P > 0.05). No injured nerve or other severe complications occurred in both groups; one of the patients from group A had back and loin pain lasting for about one month, which resolved after analgesia and functional training. There was no significant difference between the two groups in incidence of complications. Novel percutaneous pedicle screws with angle reset function can achieve the same effect as traditional open pedicle screw fixation in the treatment of thoracolumbar fractures without nerve injuries. Percutaneous minimally invasive pedicle screw fixation has the characteristics of shorter operative time, less bleeding, and less pain, but it needs more radiation times.
Hover and wind-tunnel testing of shrouded rotors for improved micro air vehicle design
NASA Astrophysics Data System (ADS)
Pereira, Jason L.
The shrouded-rotor configuration has emerged as the most popular choice for rotary-wing Micro Air Vehicles (MAVs), because of the inherent safety of the design and the potential for significant performance improvements. However, traditional design philosophies based on experience with large-scale ducted propellers may not apply to the low-Reynolds-number (˜20,000) regime in which MAVs operate. An experimental investigation of the effects of varying the shroud profile shape on the performance of MAV-scale shrouded rotors has therefore been conducted. Hover tests were performed on seventeen models with a nominal rotor diameter of 16 cm (6.3 in) and various values of diffuser expansion angle, diffuser length, inlet lip radius and blade tip clearance, at various rotor collective angles. Compared to the baseline open rotor, the shrouded rotors showed increases in thrust by up to 94%, at the same power consumption, or reductions in power by up to 62% at the same thrust. These improvements surpass those predicted by momentum theory, due to the additional effect of the shrouds in reducing the non-ideal power losses of the rotor. Increasing the lip radius and decreasing the blade tip clearance caused performance to improve, while optimal values of diffuser angle and length were found to be 10 and 50% of the shroud throat diameter, respectively. With the exception of the lip radius, the effects of changing any of the shrouded-rotor parameters on performance became more pronounced as the values of the other parameters were changed to degrade performance. Measurements were also made of the wake velocity profiles and the shroud surface pressure distributions. The uniformity of the wake was improved by the presence of the shrouds and by decreasing the blade tip clearance, resulting in lower induced power losses. For high net shroud thrust, a favorable pressure distribution over the inlet was seen to be more important than in the diffuser. Strong suction pressures were observed above the blade-passage region on the inlet surface; taking advantage of this phenomenon could enable further increases in thrust. However, trade studies showed that, for a given overall aircraft size limitation, and ignoring considerations of the safety benefits of a shroud, a larger-diameter open rotor is more likely to give better performance than a smaller-diameter shrouded rotor. The open rotor and a single shrouded-rotor model were subsequently tested at a single collective in translational flight, at angles of attack from 0° (axial flow) to 90° (edgewise flow), and at various advance ratios. In axial flow, the net thrust and the power consumption of the shrouded rotor were lower than those of the open rotor. In edgewise flow, the shrouded rotor produced greater thrust than the open rotor, while consuming less power. Measurements of the shroud surface pressure distributions illustrated the extreme longitudinal asymmetry of the flow around the shroud, with consequent pitch moments much greater than those exerted on the open rotor. Except at low airspeeds and high angles of attack, the static pressure in the wake did not reach ambient atmospheric values at the diffuser exit plane; this challenges the validity of the fundamental assumption of the simple-momentum-theory flow model for short-chord shrouds in translational flight.
Open ocean Internal Waves, Namibia Coast, Africa.
1990-12-10
These open ocean Internal Waves were seen off the Namibia Coast, Africa (23.0S, 14.0E). The periodic and regularly spaced sets of internal waves most likely coincide with tidal periods about 12 hours apart. The wave length (distance from crest to crest) varies between 1.5 and 5.0 miles and the crest lengths stretch across and beyond the distance of the photo. The waves are intersecting the Namibia coastline at about a 30 degree angle.
Open ocean Internal Waves, Namibia Coast, Africa.
NASA Technical Reports Server (NTRS)
1990-01-01
These open ocean Internal Waves were seen off the Namibia Coast, Africa (23.0S, 14.0E). The periodic and regularly spaced sets of internal waves most likely coincide with tidal periods about 12 hours apart. The wave length (distance from crest to crest) varies between 1.5 and 5.0 miles and the crest lengths stretch across and beyond the distance of the photo. The waves are intersecting the Namibia coastline at about a 30 degree angle.
Brunk, W.O.
1959-09-29
A description is given for an improved calutron receiver having a face plate lying at an angle to the direction of the entering ion beams but having an opening, the plane of which is substantially perpendicular to that of the entering ion beams. By so positioning the opening in the receiver, the effective area through which the desired material may enter the receiver is increased, and at the same time the effective area through which containattng material may enter the receiver is reduced.
John F. Kennedy Space Center's Wireless Hang Angle Instrumentation System
NASA Technical Reports Server (NTRS)
Kohler, Jeff
2009-01-01
The technology is a high-precision, wireless inclinometer. The system was designed for monitoring the suspension angle of the Orbiter vehicle during loading onto the Solid Rocket Boosters of the Space Shuttle. Originally, operators manually measured the alignment of the Orbiter with a hand-held inclinometer on a nonrigid surface. The measurement was open to interpretation by the loader. If the Orbiter is misaligned, it can crush ball joints and delay the loading while repairs are made. With this system, the Orbiter can be loaded without damage and without manual measurement.
Dermatoglyphic characters and physique: a correlation study.
Rothhammer, F; Llop, E; Neel, J V
1982-01-01
The association of anthropometrics, particularly hand measurements, with dermatoglyphic characters is quantified. Children with square hands exhibit higher main line indices, a-b ridge counts, and more open atd angles. Adults with broader hands have more arches. Taller individuals with larger hands present higher a-b ridge counts and leaner subjects with long narrow hands, closer atd angles. The correlation of physique and dermatoglyphics is small but if verified, suggests that at early fetal stages, factors responsible for the establishment of dermatoglyphic patterns interact with genetic determinants of adult shape that are already active.
The very low angle detector for high-energy inelastic neutron scattering on the VESUVIO spectrometer
NASA Astrophysics Data System (ADS)
Perelli Cippo, E.; Gorini, G.; Tardocchi, M.; Pietropaolo, A.; Andreani, C.; Senesi, R.; Rhodes, N. J.; Schooneveld, E. M.
2008-05-01
The Very Low Angle Detector (VLAD) bank has been installed on the VESUVIO spectrometer at the ISIS spallation neutron source. The new device allows for high-energy inelastic neutron scattering measurements, at energies above 1 eV, maintaining the wave vector transfer lower than 10Å-1. This opens a still unexplored region of the kinematical (q, ω) space, enabling new and challenging experimental investigations in condensed matter. This paper describes the main instrumental features of the VLAD device, including instrument design, detector response, and calibration procedure.
Planar waveguide nanolaser configured by dye-doped hybrid nanofilm on substrate
NASA Astrophysics Data System (ADS)
Tikhonov, E. A.; Yashchuk, V. P.; Telbiz, G. M.
2018-04-01
Dye-doped hybrid silicate/titanium nanofilms on the glass substrate structures of asymmetrical waveguides were studied by way of laser systems. The threshold, spatial and spectral features of the laser oscillation of genuine and hollow waveguides were determined. The pattern of stimulated radiation included two concurrent processes: single-mode waveguide lasing and lateral small divergence emission. Comparison of the open angle of the lateral beams and grazing angles of the waveguide lasing mode provides an insight into the effect of leaky mode emission followed by Lummer-Gehrcke interference.
NASA Astrophysics Data System (ADS)
Diasinos, S.; Gatto, A.
2008-09-01
This paper details a quantitative 3D investigation using LDA into the interaction aerodynamics on a sub-scale open wheel race car inverted front wing and wheel. Of primary importance to this study was the influence of changing wing angle of attack and span on the resulting near-field and far-field flow characteristics. Results obtained showed that both variables do have a significant influence on the resultant flow-field, particularly on wing vortex and wheel wake development and propagation.
Filippova, Ekaterina V; Weigand, Steven; Osipiuk, Jerzy; Kiryukhina, Olga; Joachimiak, Andrzej; Anderson, Wayne F
2015-11-06
The spermidine N-acetyltransferase SpeG is a dodecameric enzyme that catalyzes the transfer of an acetyl group from acetyl coenzyme A to polyamines such as spermidine and spermine. SpeG has an allosteric polyamine-binding site and acetylating polyamines regulate their intracellular concentrations. The structures of SpeG from Vibrio cholerae in complexes with polyamines and cofactor have been characterized earlier. Here, we present the dodecameric structure of SpeG from V. cholerae in a ligand-free form in three different conformational states: open, intermediate and closed. All structures were crystallized in C2 space group symmetry and contain six monomers in the asymmetric unit cell. Two hexamers related by crystallographic 2-fold symmetry form the SpeG dodecamer. The open and intermediate states have a unique open dodecameric ring. This SpeG dodecamer is asymmetric except for the one 2-fold axis and is unlike any known dodecameric structure. Using a fluorescence thermal shift assay, size-exclusion chromatography with multi-angle light scattering, small-angle X-ray scattering analysis, negative-stain electron microscopy and structural analysis, we demonstrate that this unique open dodecameric state exists in solution. Our combined results indicate that polyamines trigger conformational changes and induce the symmetric closed dodecameric state of the protein when they bind to their allosteric sites. Copyright © 2015. Published by Elsevier Ltd.
Filippova, Ekaterina V.; Weigand, Steven J.; Osipiuk, Jerzy; ...
2015-09-26
The spermidine N-acetyltransferase SpeG is a dodecameric enzyme that catalyzes the transfer of an acetyl group from acetyl coenzyme A to polyamines such as spermidine and spermine. SpeG has an allosteric polyamine-binding site and acetylating polyamines regulate their intracellular concentrations. The structures of SpeG from Vibrio cholerae in complexes with polyamines and cofactor have been characterized earlier. Here, we present the dodecameric structure of SpeG from V. cholerae in a ligand-free form in three different conformational states: open, intermediate and closed. All structures were crystallized in C2 space group symmetry and contain six monomers in the asymmetric unit cell. Twomore » hexamers related by crystallographic 2-fold symmetry form the SpeG dodecamer. The open and intermediate states have a unique open dodecameric ring. This SpeG dodecamer is asymmetric except for the one 2-fold axis and is unlike any known dodecameric structure. Using a fluorescence thermal shift assay, size-exclusion chromatography with multi-angle light scattering, small-angle X-ray scattering analysis, negative-stain electron microscopy and structural analysis, we demonstrate that this unique open dodecameric state exists in solution. As a result, our combined results indicate that polyamines trigger conformational changes and induce the symmetric closed dodecameric state of the protein when they bind to their allosteric sites.« less
Zhu, Feng; Wang, Bin; Zhu, Zezhang; Yu, Yang; Sun, Xu; Ma, Weiwei
2010-01-01
The traditional method of thoracoabdominal retroperitoneal approach requires dissection of diaphragm which bears potential complications such as postoperatively weakened abdominal breathing and dysfunction of diaphragm. Mini-open anterior instrumentation with diaphragm sparing is designed to minimize the damage to diaphragm and improve cosmesis. This study compared the traditional anterior instrumentation and mini-open anterior instrumentation under the hypothesis that both results in similar surgical outcomes in treating thoracolumbar scoliosis. In Group A, 38 patients with an average age of 16.5 years underwent mini-open anterior instrumentation with diaphragm sparing. The average standing coronal Cobb angle was 56.4° in Group A. Thirty-eight patients with average age of 16.7 years in Group B received traditional open approach. The preoperative average Cobb angle was 55.8° in Group B. The average correction rate of coronal curve was 78% in group A while 75% in group B. No statistical difference between the two groups in terms of coronal curve correction, sagittal profile restoration and estimated blood loss was observed. The operation time was significantly higher in Group A than that in Group B. All patients in the two groups had good healing of incisions without neurological and instrumental complications during minimal 2 year follow-up. In Groups A and B, two patients suffered from pleural effusion, respectively. The wedging of the vertebral discs distal to the lowest fused level occurred in three and four patients in Group A and B, respectively. One case in group B was found to be suspicious pseudoarthrosis without loss of correction. Mini-open anterior instrumentation with diaphragm sparing could minimize the surgical invasion as well as achieve similar clinical outcomes compared with classical anterior approach. PMID:21181213
Lai, Mun Chun; Rikhraj, Inderjeet Singh; Woo, Yew Lok; Yeo, William; Ng, Yung Chuan Sean; Koo, Kevin
2018-03-01
Minimally invasive surgeries have gained popularity due to less soft tissue trauma and better wound healing. To date, limited studies have compared the outcomes of percutaneous and open osteotomies. This study aims to investigate the clinical and radiological outcomes of percutaneous chevron-Akin osteotomies vs open scarf-Akin osteotomies at 24-month follow-up. We reviewed a prospectively collected database in a tertiary hospital hallux valgus registry. Twenty-nine feet that underwent a percutaneous technique were matched to 58 feet that underwent open scarf and Akin osteotomies. Clinical outcome measures assessed included visual analog scale (VAS) scores, American Orthopaedic Foot & Ankle Society Hallux Metatarsophalangeal-Interphalangeal score (AOFAS Hallux MTP-IP), and Short Form 36 (SF-36) Health Survey. Radiological outcomes included hallux valgus angle (HVA) and intermetatarsal angle (IMA). All patients were prospectively followed up at 6 and 24 months. Both groups showed comparable clinical and radiological outcomes at the 24-month follow-up. However, the percutaneous group demonstrated less pain in the perioperative period ( P < .001). There were significant differences in the change in HVA between the groups but comparable radiological outcomes in IMA at the 24-month follow-up. The percutaneous group demonstrated shorter length of operation ( P < .001). There were no complications in the percutaneous group but 3 wound complications in the open group. We conclude that clinical and radiological outcomes of third-generation percutaneous chevron-Akin osteotomies were comparable with open scarf and Akin osteotomies at 24 months but with significantly less perioperative pain, shorter length of operation, and less risk of wound complications. Level III, retrospective comparative series.
Proximal Opening Wedge Osteotomy Provides Satisfactory Midterm Results With a Low Complication Rate.
Oravakangas, Rami; Leppilahti, Juhana; Laine, Vesa; Niinimäki, Tuukka
2016-01-01
Hallux valgus is one of the most common foot deformities. Proximal opening wedge osteotomy is used for the treatment of moderate and severe hallux valgus with metatarsus primus varus. However, hypermobility of the first tarsometatarsal joint can compromise the results of the operation, and a paucity of midterm results are available regarding proximal open wedge osteotomy surgery. The aim of the present study was to assess the midterm results of proximal open wedge osteotomy in a consecutive series of patients with severe hallux valgus. Thirty-one consecutive adult patients (35 feet) with severe hallux valgus underwent proximal open wedge osteotomy. Twenty patients (35.5%) and 23 feet (34.3%) were available for the final follow-up examination. The mean follow-up duration was 5.8 (range 4.6 to 7.0) years. The radiologic measurements and American Orthopaedic Foot and Ankle Society hallux-metatarsophalangeal-interphalangeal scores were recorded pre- and postoperatively, and subjective questionnaires were completed and foot scan analyses performed at the end of the follow-up period. The mean hallux valgus angle decreased from 38° to 23°, and the mean intermetatarsal angle correction decreased from 17° to 10°. The mean improvement in the American Orthopaedic Foot and Ankle Society hallux metatarsophalangeal-interphalangeal score increased from 52 to 84. Two feet (5.7%) required repeat surgery because of recurrent hallux valgus. No nonunions were identified. Proximal open wedge osteotomy provided satisfactory midterm results in the treatment of severe hallux valgus, with a low complication rate. The potential instability of the first tarsometatarsal joint does not seem to jeopardize the midterm results of the operation. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, William; Crewson, Cody; Alexander, Andrew
Objective: The dosimetric characterization of an accessory-mounted mini-beam collimator across three beam matched linear accelerators. Materials and Methods: Percent depth dose and profiles were measured for the open and mini-beam collimated fields. The average beam quality and peak-to-valley dose ratio (PVDR), the ratio of average peak dose to average valley dose, were obtained from these measurements. The open field relative output and the mini-beam collimator factor, the ratio of the mini-beam dose to open field dose at the beam center, were measured for square fields of side 2, 3, 4, and 5 cm. Mini-beam output as a function of collimatormore » inclination angle relative to the central axis was also investigated. Results and Discussion: Beam quality for both the open and mini-beam collimated fields agreed across all linacs to within ±1.0%. The PVDR was found to vary by up to ±6.6% from the mean. For the 2, 3, and 4 cm fields the average open field relative output with respect to the 5 cm field was 0.874±0.4%, 0.921±0.3%, and 0.962±0.1%. The average collimator factors were 0.450±3.9%, 0.443±3.9%, 0.438±3.9%, and 0.434±3.9%. A decrease in collimator factor greater than 7% was found for an inclination angle change of 0.09°. Conclusion: The mini-beam collimator has revealed a difference between the three linacs not apparent in the open field data, yet transferability can still be attained through thorough dosimetric characterization.« less
Broadband and polarization reflectors in the lookdown, Selene vomer.
Zhao, Shulei; Brady, Parrish Clawson; Gao, Meng; Etheredge, Robert Ian; Kattawar, George W; Cummings, Molly E
2015-03-06
Predator evasion in the open ocean is difficult because there are no objects to hide behind. The silvery surface of fish plays an important role in open water camouflage. Various models have been proposed to account for the broadband reflectance by the fish skin that involve one-dimensional variations in the arrangement of guanine crystal reflectors, yet the three-dimensional organization of these guanine platelets have not been well characterized. Here, we report the three-dimensional organization and the optical properties of integumentary guanine platelets in a silvery marine fish, the lookdown (Selene vomer). Our structural analysis and computational modelling show that stacks of guanine platelets with random yaw angles in the fish skin produce broadband reflectance via colour mixing. Optical axes of the guanine platelets and the collagen layer are aligned closely and provide bulk birefringence properties that influence the polarization reflectance by the skin. These data demonstrate how the lookdown preserves or alters polarization states at different incident polarization angles. These optical properties resulted from the organization of these guanine platelets and the collagen layer may have implications for open ocean camouflage in varying light fields. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
NASA Astrophysics Data System (ADS)
Osterhoudt, Curtis F.; Marston, Philip L.
2003-04-01
A simple target for simulating narrow low-frequency resonances of cylinders is an open metal pipe completely filled with water. We have previously described how the high-Q organ-pipe modes having a pressure node near each end are easily observed in backscattering experiments with small cylinders [C. F. Osterhoudt and P. L. Marston, J. Acoust. Soc. Am. 110, 2773 (2001)]. The resonance occurs because of the strong reflection of internal acoustic waves from the open ends of the pipe [H. Levine and J. Schwinger, Phys. Rev. 73, 383-406 (1948)]. In the present research, the dependence of the backscattering amplitude on the orientation of the cylinder is measured and modeled. The tilt angle dependence is affected by the symmetry of the organ pipe mode. An approximation was also developed for the backscattering amplitude at high Q resonances based on energy conservation, reciprocity, and the optical theorem. While this analysis applies to cylinders suspended in water away from boundaries, the organ-pipe modes studied may be useful for investigating scattering processes for buried or partially buried cylinders. [Research supported in part by ONR.
Development of a prototype Open-close positron emission tomography system
NASA Astrophysics Data System (ADS)
Yamamoto, Seiichi; Okumura, Satoshi; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Toshito, Toshiyuki; Komori, Masataka; Ogata, Yoshimune; Kato, Katsuhiko; Hatazawa, Jun
2015-08-01
We developed a prototype positron emission tomography (PET) system based on a new concept called Open-close PET, which has two modes: open and close-modes. In the open-mode, the detector ring is separated into two halved rings and subject is imaged with the open space and projection image is formed. In the close-mode, the detector ring is closed to be a regular circular ring, and the subject can be imaged without an open space, and so reconstructed images can be made without artifacts. The block detector of the Open-close PET system consists of two scintillator blocks that use two types of gadolinium orthosilicate (GSO) scintillators with different decay times, angled optical fiber-based image guides, and a flat panel photomultiplier tube. The GSO pixel size was 1.6 × 2.4 × 7 mm and 8 mm for fast (35 ns) and slow (60 ns) GSOs, respectively. These GSOs were arranged into an 11 × 15 matrix and optically coupled in the depth direction to form a depth-of-interaction detector. The angled optical fiber-based image guides were used to arrange the two scintillator blocks at 22.5° so that they can be arranged in a hexadecagonal shape with eight block detectors to simplify the reconstruction algorithm. The detector ring was divided into two halves to realize the open-mode and set on a mechanical stand with which the distance between the two parts can be manually changed. The spatial resolution in the close-mode was 2.4-mm FWHM, and the sensitivity was 1.7% at the center of the field-of-view. In both the close- and open-modes, we made sagittal (y-z plane) projection images between the two halved detector rings. We obtained reconstructed and projection images of 18F-NaF rat studies and proton-irradiated phantom images. These results indicate that our developed Open-close PET is useful for some applications such as proton therapy as well as other applications such as molecular imaging.
Kinematic error magnitude in the single-mass inverted pendulum model of human standing posture.
Fok, Kai Lon; Lee, Jae; Vette, Albert H; Masani, Kei
2018-06-01
Many postural control studies employ a single-mass inverted pendulum model (IPM) to represent the body during standing. However, it is not known to what degree and for what conditions the model's kinematic assumptions are valid. Our first objective was to quantify the IPM error, corresponding to a distance change between the ankle joint and center of mass (COM) during unrestricted, natural, unperturbed standing. A second objective was to quantify the error of having the ankle joint angle represent the COM angle. Eleven young participants completed five standing conditions: quiet standing with eyes open (EO) and closed (EC), voluntarily swaying forward (VSf) and backward (VSb), and freely moving (FR). The modified Helen-Hayes marker model was used to capture the body kinematics. The COM distance changed <0.1% during EO and EC, <0.25% during VSf and VSb, and <1.5% during FR. The ankle angle moderately and positively correlated with the COM angle for EO, EC, and VSf, indicating that temporal features of the ankle angle moderately represent those of the COM angle. However, a considerable offset between the two existed, which needs to be considered when estimating the COM angle using the ankle angle. For VSb and FR, the correlation coefficients were low and/or negative, suggesting that a large error would result from using the ankle angle as an estimate of the COM angle. Insights from this study will be critical for deciding when to use the IPM in postural control research and for interpreting associated results. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yi, Bo; Shen, Huifang
2018-01-01
Non-iridescent structural colors and lotus effect universally existing in the nature provide a great inspiration for artificially developing angle-independent and high hydrophobic structurally colored films. To this end, a facile strategy is put forward for achieving superhydrophobic structurally colored films with wide viewing angles and high visibility based on bumpy melanin-like polydopamine-coated polystyrene particles. Here, hierarchical and amorphous structures are assembled in a self-driven manner due to particles' protrusive surfaces. The superhydrophobicity of the structurally colored films, with water contact angle up to 151°, is realized by combining the hierarchical surface roughness with a dip-coating process of polydimethylsiloxane-hexane solution, while angle-independence revealed in the films is ascribed to amorphous arrays. In addition, benefited from an essential light-absorbing property and high refractive index of polydopamine, the visibility of as-prepared colored films is fundamentally enhanced. Moreover, the mechanical robustness of the films is considerably boosted by inletting 3-aminopropyltriethoxysilane. This fabrication strategy might provide an opportunity for promoting the open-air application of structurally colored coatings.
Friction Angles of Open-Graded Aggregates from Large-Scale Direct Shear Testing : TechBrief
DOT National Transportation Integrated Search
2013-07-08
State and local transportation agencies frequently use opengraded aggregates for wall, roadway, and bridge construction. The primary advantages of using this type of material in wall and abutment applications are ease of constructability, lighter in-...
NASA Technical Reports Server (NTRS)
Blair, A. B., Jr.; Stallings, R. L., Jr.
1986-01-01
A wind-tunnel investigation has been conducted at Mach numbers of 1.50, 2.16, and 2.86 to obtain axial-force data on a metric rectangular-box cavity with various length-to-depth ratios. The model was tested at angles of attack from -4 deg to -2 deg. The results are summarized to show variations in cavity axial-force coefficient for deep- and shallow-cavity configurations with detached and attached cavity flow fields, respectively. The results of the investigation indicate that for a wide range of cavity lengths and depths, good correlations of the cavity axial-force coefficients (based on cavity rear-face area) are obtained when these coefficients are plotted as a function of cavity length-to-depth ratio. Abrupt increases in the cavity axial-force coefficients at an angle of attack of 0 deg. reflect the transition from an open (detached) cavity flow field to a closed (attached) cavity flow field. Cavity length-to-depth ratio is the dominant factor affecting the switching of the cavity flow field from one type to the other. The type of cavity flow field (open or closed) is not dependent on the test angles of attack except near the critical value of length-to-depth ratio.
Sun, Hao; Zhou, Lin; Li, Fengsheng; Duan, Jun
2017-02-01
Young active patients with medial knee osteoarthritis (OA) combined with varus leg alignment can be treated with high tibial osteotomy (HTO) to stop the progression of OA and avoid or postpone total knee arthroplasty (TKA). Closing-wedge osteotomy (CWO) and opening-wedge osteotomy (OWO) are the most commonly used osteotomy techniques. The purpose of this study was to compare the clinical and radiologic outcomes and complications between OWO and CWO. We retrospectively evaluated 23 studies including 17 clinical trials from published databases from their inception to May 2015. We evaluated the clinical outcomes including operation time, visual analog scale (VAS), maximal flexion, and hospital for special surgery knee (HSS) score. The radiologic outcomes included patellar height measured by posterior tibial slope angle, hip-knee-ankle (HKA) angle, femorotibial (FT) axis, and limb length. Complications recorded included the incidence of deep vein thrombosis (DVT), common peroneal nerve injury, opposite cortical fracture, etc. There were no differences in most of the clinical outcomes except the operation time. OWO increased the posterior slope angle and limb length, decreased the patellar height, and provided higher accuracy of correction. CWO led to a higher incidence of opposite cortical fracture. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Separation of Migration and Tomography Modes of Full-Waveform Inversion in the Plane Wave Domain
NASA Astrophysics Data System (ADS)
Yao, Gang; da Silva, Nuno V.; Warner, Michael; Kalinicheva, Tatiana
2018-02-01
Full-waveform inversion (FWI) includes both migration and tomography modes. The migration mode acts like a nonlinear least squares migration to map model interfaces with reflections, while the tomography mode behaves as tomography to build a background velocity model. The migration mode is the main response of inverting reflections, while the tomography mode exists in response to inverting both the reflections and refractions. To emphasize one of the two modes in FWI, especially for inverting reflections, the separation of the two modes in the gradient of FWI is required. Here we present a new method to achieve this separation with an angle-dependent filtering technique in the plane wave domain. We first transform the source and residual wavefields into the plane wave domain with the Fourier transform and then decompose them into the migration and tomography components using the opening angles between the transformed source and residual plane waves. The opening angles close to 180° contribute to the tomography component, while the others correspond to the migration component. We find that this approach is very effective and robust even when the medium is relatively complicated with strong lateral heterogeneities, highly dipping reflectors, and strong anisotropy. This is well demonstrated by theoretical analysis and numerical tests with a synthetic data set and a field data set.
Mansouri, Mohammadreza; Ramezani, Farshid; Moghimi, Sasan; Tabatabaie, Ali; Abdi, Fatemeh; He, Mingguang; Lin, Shan C
2014-10-21
To describe anterior segment optical coherence tomography (AS-OCT) parameters in phacomorphic angle closure eyes, mature cataract eyes, and their fellow eyes, and identify those parameters that could be used to differentiate phacomorphic angle closure eyes from those with mature cataract and no phacomorphic angle closure. In this cross-sectional study, a total of 33 phacomorphic angle closure subjects and 34 control patients with unilateral mature cataracts were enrolled. All patients underwent AS-OCT imaging and A-scan biometry of both eyes. Anterior chamber depth (ACD), anterior chamber area (ACA), iris thickness, iris curvature, lens vault (LV), and angle parameters, including angle opening distance (AOD750) and trabecular-iris space area (TISA750), were measured in qualified images using customized software and compared among eyes with phacomorphic angle closure, mature cataract eyes, and their fellow eyes. There was no significant difference in axial length among the four groups. Phacomorphic angle closure had the smallest angle (AOD750, TISA750) and anterior chamber parameters (ACD, ACA, anterior chamber width) and the greatest LV among the groups. This pattern was similar when comparing fellow eyes of mature cataract patients and fellow eyes of phacomorphic angle closure. Anterior chamber area less than 18.62 mm(2), ACD less than 2.60 mm, LV greater than 532.0 μm, and AOD750 less than 0.218 mm had the highest odds ratios (ORs) for distinguishing fellow eyes of phacomorphic angle closure versus fellow eyes of mature cataracts, with OR values of 9.90, 8.31, 7.91, and 7.91, respectively. Logistic regression showed that ACA less than 18.62 was the major parameter associated with fellow eyes of phacomorphic angle closure (OR = 10.96, P < 0.001). Anterior chamber depth, ACA, AOD750, and LV are powerful indicators in differentiating phacomorphic angle closure eyes from those with mature cataract and their fellow eyes. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
NASA Technical Reports Server (NTRS)
Schwartz, Robert W.; Ballato, J.; Northwang, W. D.; Laoratanakul, P.
2000-01-01
Dome formation in Rainbow and Thunder actuators occurs to relieve thermal expansion mismatch stress between the metallic and piezoelectric layers during cooling from device fabrication temperatures. Accompanying this process is the generation of an internal stress profile within the devices and the development of significant tensile stresses within the surface region of the piezoelectric. These tensile stresses affect the domain configuration (ratio of c-to-a domains), and improve the 90 deg. domain wall movement response of the device in this region of the piezoelectric. This results in improved electromechanical performance compared to standard direct extensional and flextensional devices, presumably because of the contributions of stress to the non-linearity of the piezoelectric d-coefficients. 1 Interestingly, this improvement in response seems counterintuitive; a stress perpendicular to the direction of the applied electric field should impede, not contribute to 90' domain switching. Further consideration of the lower region of the piezoelectric that is under compressive stress thus appears warranted. The specified objectives of the research were to: 1. Conduct finite element and equivalent circuit simulation-based investigations to understand the effects of actuator geometry on internal stress distribution and actuator performance (displacement and load-bearing capabilities). 2. Use the results of the modeling studies to predict the processing conditions (geometry and thickness ratio) required for the fabrication of Rainbow ceramics with optimized performance.
Effects of Leaflet Design on Transvalvular Gradients of Bioprosthetic Heart Valves.
Dabiri, Yaghoub; Ronsky, Janet; Ali, Imtiaz; Basha, Ameen; Bhanji, Alisha; Narine, Kishan
2016-12-01
Bioprosthetic aortic valves (BAVs) are becoming the prostheses of choice in heart valve replacement. The objective of this paper is to assess the effects of leaflet geometry on the mechanics and hemodynamics of BAVs in a fluid structure interaction model. The curvature and angle of leaflets were varied in 10 case studies whereby the following design parameters were altered: a circular arch, a line, and a parabola for the radial curvature, and a circular arch, a spline, and a parabola for the circumferential curvature. Six different leaflet angles (representative of the inclination of the leaflets toward the surrounding aortic wall) were analyzed. The 3-dimensional geometry of the models were created using SolidWorks, Pointwise was used for meshing, and Comsol Multiphysics was used for implicit finite element calculations. Realistic loading was enforced by considering the time-dependent strongly-coupled interaction between blood flow and leaflets. Higher mean pressure gradients as well as von Mises stresses were obtained with a parabolic or circular curvature for radial curvature or a parabolic or spline curvature for the circumferential curvature. A smaller leaflet angle was associated with a lower pressure gradient, and, a lower von Mises stress. The leaflet curvature and angle noticeably affected the speed of valve opening, and closing. When a parabola was used for circumferential or radial curvature, leaflets displacements were asymmetric, and they opened and closed more slowly. A circular circumferential leaflet curvature, a linear leaflet radial curvature, and leaflet inclination toward the surrounding aortic wall were associated with superior BAVs mechanics.
Kumar, Addepalli U.; Jonnadula, Ganesh B.; Garudadri, Chandrasekhar; Rao, Harsha L.; Senthil, Sirisha; Papas, Eric B.; Sankaridurg, Padmaja; Khanna, Rohit C.
2013-01-01
Purpose To compare the diagnostic performance of glaucoma specialists and experienced optometrists in gonioscopy and optic disc assessment. Methods This study was done to validate the diagnostic performance of two experienced optometrists for using their skills of detecting glaucoma using gonioscopy and optic disc assessment in a major epidemiological study, the L V Prasad Eye Institute Glaucoma Epidemiology and Molecular Genetics Study (LVPEI-GLEAMS). Gonioscopic findings for 150 eyes were categorized as 0, 1 and 2 for open angle, primary angle closure suspect (PACS) and primary angle closure (PAC) respectively. Optic disc findings for 200 eyes were categorized as 0, 1 and 2 for normal, suspects and glaucomatous respectively. Weighted kappa (κ) and diagnostic accuracy parameters were calculated. Two optometrists (#1 and #2) participated in the study. Results Agreement between glaucoma specialists and optometrist for interpretation of gonioscopy to discriminate PACS and PAC from open angles and for interpretation of optic disc to discriminate glaucomatous and suspicious discs from normal, the kappa (κ) was 0.92 and 0.84 and 0.90 and 0.89 for optometrists #1 and #2 respectively. Sensitivities and specificities were above 90% for gonioscopy. Optic disc evaluation had specificities greater than 95% to discriminate normal from glaucomatous discs while the sensitivities were 83% and 93% for optometrists #1 and #2 respectively. Conclusion Agreement between optometrists and glaucoma specialists, in diagnostic performance of gonioscopy and optic assessment was excellent with high sensitivity and specificity. Hence, we conclude that the experienced optometrists can detect glaucoma accurately in the LVPEI-GLEAMS.
Park, H-Yl; Hwang, Y S; Park, C K
2017-04-01
PurposeTo investigate the clinical characteristics according to the location of focal lamina cribrosa (LC) defects and its associated ocular features.Patients and methodsA total of 139 open-angle glaucoma patients underwent Spectralis optical coherence tomography (OCT) with enhanced depth imaging. Alterations in the contour of the LC were investigated to find focal LC defects. The location of the visible LC defect from the neural canal wall (far-peripheral and mid-peripheral) and clock-hour position (superotemporal, temporal and inferotemporal) were classified. Disc ovality ratio and disc-foveal angle were measured from disc and retinal nerve fiber layer (RNFL) photographs. The disc tilt degree was measured using a Heidelberg Retina Tomograph (HRT) III system. The en face OCT image of the disc scans was registered to the disc and RNFL photographs, to determine whether the focal LC defects corresponded spatially to the glaucomatous damage location.ResultsEyes with far-peripheral LC defects were significantly myopic and had a higher disc ovality ratio. The disc tilt degree obtained by HRT revealed significant temporal disc tilt in eyes with temporal LC defects (P<0.001). Eyes with inferotemporal LC defects had a significantly larger disc-foveal angle (P=0.027). The inferotemporal LC defects corresponded to the location of glaucomatous damage in 81.6%; however, only 46.2% of eyes with a superotemporal LC defect and 3.2% of eyes with a temporal LC defect corresponded spatially with the glaucomatous damage location.ConclusionsThe clinical characteristics and association with glaucomatous damage location were different according to the location of focal LC defect.
Open Ocean Internal Waves, South China Sea
NASA Technical Reports Server (NTRS)
1989-01-01
These open ocean internal waves were seen in the south China Sea (19.5N, 114.5E). These sets of internal waves most likely coincide with tidal periods about 12 hours apart. The wave length (distance from crest to crest) varies between 1.5 and 5.0 miles and the crest lengths stretch across and beyond this photo for over 75 miles. At lower right, the surface waves are moving at a 30% angle to the internal waves, with parallel low level clouds.
2010-07-30
from Xu et al., 2005). (b) Map of SMU-IGPCEA Huailai Seismic Network and seismicity ( open circles) for the time period of January 01, 2002 through...the Beijing-Huailai-Fengzhen (H20) refraction/ wide angle reflection profile (Zhu et al., 1997). Open circles are locations of two historical...historycatalog_query.jsp) and the China Seismograph Network ( CSN ) Catalog (http://210.72.96.165/wdcd/csn_catalog_p001.jsp) list a total of 323 earthquakes with magnitude
Prevention of Blindness: Chronic Glaucoma
ERIC Educational Resources Information Center
Richardson, Kenneth T.
1970-01-01
An evaluation of present screening procedures for chronic open-angle glaucoma includes suggestions for improvement: greater distribution of screening and education, conversion from monophasic to multiphasic screen, and examination of visual fields, optic nerve, and medical history in addition to the tonometry currently done. (KW)
... Glaucoma Facts and Stats Glossary Symptoms of Open-Angle Glaucoma Types of Glaucoma » See All Articles Where the Money Goes Have a Question? Browse Our Q&A » Or e-mail us: question@ glaucoma.org For medical advice, contact your doctor. Our Newsletter Stay up-to-date ...
Pine Island Glacier, Antarctica, MISR Multi-angle Composite
2013-11-15
NASA Terra satellite passed over the Pine Island Glacier in Antarctica around Oct. 27, 2013, just days before iceberg B-31 broke completely free. B-31 is finally moving away from the coast, with open water between the iceberg and the glacier.
Isolated Open Rotor Noise Prediction Assessment Using the F31A31 Historical Blade Set
NASA Technical Reports Server (NTRS)
Nark, Douglas M.; Jones, William T.; Boyd, D. Douglas, Jr.; Zawodny, Nikolas S.
2016-01-01
In an effort to mitigate next-generation fuel efficiency and environmental impact concerns for aviation, open rotor propulsion systems have received renewed interest. However, maintaining the high propulsive efficiency while simultaneously meeting noise goals has been one of the challenges in making open rotor propulsion a viable option. Improvements in prediction tools and design methodologies have opened the design space for next generation open rotor designs that satisfy these challenging objectives. As such, validation of aerodynamic and acoustic prediction tools has been an important aspect of open rotor research efforts. This paper describes validation efforts of a combined computational fluid dynamics and Ffowcs Williams and Hawkings equation methodology for open rotor aeroacoustic modeling. Performance and acoustic predictions were made for a benchmark open rotor blade set and compared with measurements over a range of rotor speeds and observer angles. Overall, the results indicate that the computational approach is acceptable for assessing low-noise open rotor designs. Additionally, this approach may be used to provide realistic incident source fields for acoustic shielding/scattering studies on various aircraft configurations.
Wasyluk, Jaromir T.; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona
2012-01-01
Summary Background We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Material/Methods Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18–70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. Results The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in μm) differ significantly between GDx and all OCT devices. Conclusions Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients. PMID:22367131
Localization of a locus (GLC1B) for adult-onset primary open angle glaucoma to the 2cen-q13 region
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoilova, D.; Trifan, O.C.; Sarfarazi, M.
1996-08-15
Primary open angle glaucoma (GLC1) is a common ocular disorder with a characteristic degeneration of the optic nerve and visual field defects that is often associated with an elevated intraocular pressure. The severe but rare juvenile-onset type has previously been mapped to 1q21-q31, and its genetic heterogeneity has been established. Herein, we present a new locus (GLC1B) for one form of GLC1 on chromosome 2cen-q13 with a clinical presentation of low to moderate intraocular pressure, onset in late 40s, and a good response to medical treatment. Two-point and haplotype analyses of affected and unaffected meioses in six families provided maximummore » linkage information with D2S417, GATA112EO3, D2S113, D2S373, and D2S274 (lod scores ranging from 3.11 to 6.48) within a region of 8.5 cM that is flanked by D2S2161 and D2S2264. Analysis of affected meioses alone revealed no recombination with an additional two markers (D2S2264 and D2S135) in a region of 11.2 cM that is flanked by D2S2161 and D2S176. Analysis of unaffected meioses identified only one healthy 86-year-old male who has inherited the entire affected haplotype and, hence, is a gene carrier for this condition. Eight additional families with similar and/or different clinical presentation did not show any linkage to this region and, therefore, provided evidence for genetic heterogeneity of adult-onset primary open angle glaucoma. 63 refs., 2 figs., 2 tabs.« less
Aptel, Florent; Choudhry, Reena; Stalmans, Ingeborg
2016-08-01
This study compared the efficacy, safety, and pharmacokinetics of a preservative-free latanoprost formulation to an established, benzalkonium chloride (BAK) containing formulation for the treatment of open-angle glaucoma or ocular hypertension. This was a phase II, randomized, cross-over, investigator-masked, multi-center, pilot study (NCT01494753). A total of 30 untreated adult patients (aged ≥18 years) with primary open angle glaucoma, pseudo-exfoliative glaucoma, pigmentary glaucoma, or ocular hypertension received either preservative-free or preserved latanoprost once daily in both eyes for 6 weeks, before crossing over to receive the other treatment. Efficacy (intraocular pressure [IOP] at 8 am, midday, 4 pm and 8 pm, and global efficacy assessment by investigator), safety (adverse events, ocular symptoms and global tolerance, slit lamp examination, funduscopy, visual field examination, visual acuity, and heart rate), and pharmacokinetics were assessed at Days 0, 42, and 84. Both treatments resulted in a reduction in IOP that was similar for the preservative-free and the preserved formulation at all time points. Similarly, the overall diurnal reduction was similar in both groups (6.3 mmHg [27.9% reduction] and 6.4 mmHg [28.1% reduction] for preserved and preservative-free latanoprost, respectively). There were no differences in global efficacy assessment or in the safety and tolerance of each treatment. Systemic concentrations of latanoprost were very low; AUC0-30 and Cmax were lower and tmax was longer for preservative-free latanoprost. Preservative-free latanoprost showed similar efficacy at all time points compared to BAK preservative containing formulation, with no difference in tolerance, allowing progression to phase III clinical development.
Berlin, Michael S; Rowe-Rendleman, Cheryl; Ahmed, Ike; Ross, Douglas T; Fujii, Akifumi; Ouchi, Takafumi; Quach, Christine; Wood, Andrew; Ward, Caroline L
2016-01-01
Background/aims The novel prostaglandin E (EP) 3 and prostaglandin F (FP) receptor agonist ONO-9054 is effective in lowering intraocular pressure (IOP) in patients with ocular hypertension and open-angle glaucoma when administered once daily. This study compares the effects of morning (AM) versus evening (PM) dosing of ONO-9054 on tolerability and IOP lowering. Methods This was a single-centre, randomised, double-masked, two-sequence, placebo-controlled crossover study in 12 subjects with bilateral primary open-angle glaucoma or ocular hypertension. Two 14-day crossover regimens were separated by a 2-week washout: ONO-9054 (1 drop to each eye) in the morning (07:00) and vehicle in the evening (19:00) and vice versa. IOP was measured multiple times during select days. Ocular examinations also evaluated safety and tolerability. Results Mild ocular hyperaemia, reported by six subjects with PM dosing, was the most frequent adverse event. Mild to moderate dryness was also slightly more frequent after PM dosing. Maximum IOP reduction from baseline occurred on day 2 with decreases from baseline of −7.4 mm Hg (−30.8%) for AM dosing and −9.1 mm Hg, (−38.0%) for PM dosing; after 14 days, mean reduction in IOP was −6.8 mm Hg (−28.6%) for AM dosing and −7.5 mm Hg (−31.0%) for PM dosing. Conclusions PM dosing of ONO-0954 was associated with a slightly increased frequency of mild hyperaemia and mild to moderate dryness. Both dosing schedules provided sustained reduction in IOP. Trial registration number NCT01670266. PMID:26453641
Pleet, Alexander; Sulewski, Melanie; Salowe, Rebecca J; Fertig, Raymond; Salinas, Julia; Rhodes, Allison; Merritt Iii, William; Natesh, Vikas; Huang, Jiayan; Gudiseva, Harini V; Collins, David W; Chavali, Venkata Ramana Murthy; Tapino, Paul; Lehman, Amanda; Regina-Gigiliotti, Meredith; Miller-Ellis, Eydie; Sankar, Prithvi; Ying, Gui-Shuang; O'Brien, Joan M
2016-08-01
To determine the risk factors associated with progression to blindness from primary open-angle glaucoma (POAG) in an African-American population. This study examined 2119 patients enrolled in the Primary Open-Angle African-American Glaucoma Genetics (POAAGG) study. A total of 59 eyes were identified as legally blind as a result of POAG (cases) and were age-and sex-matched to 59 non-blind eyes with glaucoma (controls). Chart reviews were performed to record known and suspected risk factors. Cases were diagnosed with POAG at an earlier age than controls (p = 0.005). Of the 59 eyes of cases, 16 eyes (27.1%) presented with blindness at diagnosis. Cases had worse visual acuity (VA) at diagnosis (p < 0.0001), with VA worse than 20/40 conferring a 27 times higher risk of progression to blindness (p = 0.0005). Blind eyes also demonstrated more visual field defects (p = 0.01), higher pre-treatment intraocular pressure (IOP; p < 0.0001), and higher cup-to-disc ratio (p = 0.006) at diagnosis. IOP was less controlled in cases, and those with IOP ≥21 mmHg at more than 20% of follow-up visits were 73 times more likely to become blind (p < 0.0001). Cases missed a greater number of appointments per year (p = 0.003) and had non-adherence issues noted in their charts more often than controls (p = 0.03). However, other compliance data did not significantly differ between groups. Access to care, initial VA worse than 20/40, and poor control of IOP were the major risk factors associated with blindness from POAG. Future studies should examine earlier, more effective approaches to glaucoma screening as well as the role of genetics in these significantly younger patients who progress to blindness.
Lee, Jacky W Y; Chan, Catherine W S; Chan, Jonathan C H; Li, Q; Lai, Jimmy S M
2014-08-01
OBJECTIVE. To investigate the association between clinical measurements and glaucoma-specific quality of life in Chinese glaucoma patients. DESIGN. Cross-sectional study. SETTING. An academic hospital in Hong Kong. PATIENTS. A Chinese translation of the Glaucoma Quality of Life-15 questionnaire was completed by 51 consecutive patients with bilateral primary open-angle glaucoma. The binocular means of several clinical measurements were correlated with Glaucoma Quality of Life-15 findings using Pearson's correlation coefficient and linear regression. The measurements were the visual field index and pattern standard deviation from the Humphrey Field Analyzer, Snellen best-corrected visual acuity, presenting intra-ocular pressure, current intra-ocular pressure, average retinal nerve fibre layer thickness via optical coherence tomography, and the number of topical anti-glaucoma medications being used. RESULTS. In these patients, there was a significant correlation and linear relationship between a poorer Glaucoma Quality of Life-15 score and a lower visual field index (r=0.3, r(2)=0.1, P=0.01) and visual acuity (r=0.3, r(2)=0.1, P=0.03). A thinner retinal nerve fibre layer also correlated with a poorer Glaucoma Quality of Life-15 score, but did not attain statistical significance (r=0.3, P=0.07). There were no statistically significant correlations for the other clinical parameters with the Glaucoma Quality of Life-15 scores (all P values being >0.7). The three most problematic activities affecting quality of life were "adjusting to bright lights", "going from a light to a dark room or vice versa", and "seeing at night". CONCLUSION. For Chinese primary open-angle glaucoma patients, binocular visual field index and visual acuity correlated linearly with glaucoma-specific quality of life, and activities involving dark adaptation were the most problematic.
Rahmatnejad, Kamran; Pruzan, Noelle L; Amanullah, Sarah; Shaukat, Bilal A; Resende, Arthur F; Waisbourd, Michael; Zhan, Tingting; Moster, Marlene R
2017-12-01
To evaluate the efficacy and safety of gonioscopy-assisted transluminal trabeculotomy (GATT) in patients with open-angle glaucoma. A retrospective chart review of adult patients who underwent GATT due to inadequately controlled intraocular pressure (IOP) or intolerance to medication. Main outcome measures were success rate, IOP, and number of glaucoma medications. Success was defined as IOP reduction >20% from baseline or IOP between 5 to 21 mm Hg, and no need for further glaucoma surgery. When success criteria were not met for any postoperative visit >3 months after surgery, failure was determined. In total, 66 patients, average age 62.9±14.9 years (50.8% female) were included in the analysis. Average follow-up was 11.9 months (range, 3 to 30 mo) and overall success rate was 63.0%. Mean IOP was 26.1±9.9 mm Hg preoperatively and 14.6±4.7 mm Hg at 12 months (44% IOP decrease; P<0.001). Mean number of medications decreased from 3.1±1.1 preoperatively to 1.2±0.9 at 12 months (P<0.001). No significant differences between patients with primary open-angle glaucoma and other types of glaucoma were found.The rate of hyphema at 1 week and 1 month postoperatively was 38% and 6%, respectively. Overall GATT success rate among white and black patients was 69% and 42%, respectively, which was statistically significant (P<0.05). The future of GATT as a minimally invasive glaucoma surgery in adults seems promising. This position is supported by its low rate of long-term complications and the conjunctiva-sparing nature of the surgery.
Desai, Rajen U; Singh, Kuldev; Lin, Shan C
2013-03-01
To determine the safety and efficacy of intravitreal ranibizumab therapy before and after Ahmed tube insertion for open-angle glaucoma as a means of optimizing postoperative intraocular pressure control. Randomized, controlled trial. Open-angle glaucoma patients scheduled for Ahmed tube insertion, randomized to ranibizumab or control groups. Ranibizumab (0.5 mg in 0.05 mL) was administered intravitreally at three time points: 9 days prior to surgery, 1 month post-surgery and 2 months post-surgery. Control patients underwent the same procedure without ranibizumab. Success at 6 months postoperatively was defined as intraocular pressure <18 mmHg with no adjunctive medications or intraocular pressure <15 mmHg with one adjunctive medication. The study and control arms included six and five subjects, respectively, with four in each arm undergoing combined cataract surgery. In the ranibizumab arm, the preoperative and postoperative intraocular pressure/medication usage was 21.0 ± 6.7 mmHg on 3.2 ± 1.5 medications and 14.7 ± 1.9 mmHg on 0.5 ± 0.8 medications, respectively. In the control arm, preoperative and postoperative intraocular pressure/medication usage was 18.8 ± 3.8 mmHg on 2.8 ± 1.3 medications and 16.2 ± 3.6 mmHg with 1.8 ± 1.6 medications, respectively. Success was achieved in 83% of subjects in the ranibizumab group compared with 40% in the control group (two-tailed Fisher's exact test, P = 0.24). The findings from this small pilot comparative study suggest that intravitreal ranibizumab use may be a safe and potentially effective adjunctive treatment modality in improving success after Ahmed tube placement. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.
Morphology of AGN Emission Line Regions in SDSS-IV MaNGA Survey
NASA Astrophysics Data System (ADS)
He, Zhicheng; Sun, Ai-Lei; Zakamska, Nadia L.; Wylezalek, Dominika; Kelly, Michael; Greene, Jenny E.; Rembold, Sandro B.; Riffel, Rogério; Riffel, Rogemar A.
2018-05-01
Extended narrow-line regions (NLRs) around active galactic nuclei (AGN) are shaped by the distribution of gas in the host galaxy and by the geometry of the circumnuclear obscuration, and thus they can be used to test the AGN unification model. In this work, we quantify the morphologies of the narrow-line regions in 308 nearby AGNs (z = 0 - 0.14, Lbol˜1042.4 - 44.1 erg s-1) from the MaNGA survey. Based on the narrow-line region maps, we find that a large fraction (81%) of these AGN have bi-conical NLR morphology. The distribution of their measured opening angles suggests that the intrinsic opening angles of the ionization cones has a mean value of 85-98° with a finite spread of 39-44° (1-σ). Our inferred opening angle distribution implies a number ratio of type I to type II AGN of 1:1.6-2.3, consistent with other measurements of the type I / type II ratio at low AGN luminosities. Combining these measurements with the WISE photometry data, we find that redder mid-IR color (lower effective temperature of dust) corresponds to stronger and narrower photo-ionized bicones. This relation is in agreement with the unification model that suggests that the bi-conical narrow-line regions are shaped by a toroidal dusty structure within a few pc from the AGN. Furthermore, we find a significant alignment between the minor axis of host galaxy disks and AGN ionization cones. Together, these findings suggest that obscuration on both circumnuclear (˜pc) and galactic (˜ kpc) scales are important in shaping and orienting the AGN narrow-line regions.
Lin, Shuai-Chun; Pasquale, Louis R; Singh, Kuldev; Lin, Shan C
2018-03-01
The purpose of this article is to investigate the association between body mass index (BMI) and open-angle glaucoma (OAG) in a sample of the South Korean population. The sample consisted of a cross-sectional, population-based sample of 10,978 participants, 40 years of age and older, enrolled in the 2008 to 2011 Korean National Health and Nutrition Examination Survey. All participants had measured intraocular pressure <22 mm Hg and open anterior chamber angles. OAG was defined using disc and visual field criteria established by the International Society for Geographical and Epidemiological Ophthalmology. Multivariable analyses were performed to determine the association between BMI and OAG. These analyses were also performed in a sex-stratified and age-stratified manner. After adjusting for potential confounding variables, lower BMI (<19 kg/m) was associated with greater risk of OAG compared with normal BMI (19 to 24.9 kg/m) [odds ratio (OR), 2.28; 95% confidence interval (CI), 1.22-4.26]. In sex-stratified analyses, low BMI remained adversely related to glaucoma in women (OR, 3.45; 95% CI, 1.42-8.38) but not in men (OR, 1.72; 95% CI, 0.71-4.20). In age-stratified analyses, lower BMI was adversely related to glaucoma among subjects 40- to 49-year old (OR, 5.16; 95% CI, 1.86-14.36) but differences in glaucoma prevalence were not statistically significant between those with low versus normal BMI in other age strata. Lower BMI was associated with increased odds of OAG in a sample of the South Korean population. Multivariate analysis revealed the association to be statistically significant in women and those in the youngest age stratum.
Manchester iStent study: early results from a prospective UK case series.
Patel, Ilesh; de Klerk, Timothy A; Au, Leon
2013-01-01
To evaluate the 6-month efficacy and safety of the iStent microtrabecular bypass stent in patients with open-angle glaucoma. A prospective, uncontrolled, interventional case series. Forty-four eyes with open-angle glaucoma were reported. All subjects underwent ab interno implantation of a single iStent together with (n = 40) or without (n = 4) cataract surgery. Patients were assessed at postoperative week 1, months 1 and 3, and quarterly, thereafter. Data collected included visual acuity, intraocular pressure measurement using Goldmann tonometry, number of glaucoma medications, and number and type of complications. The mean age of the sample was 76.8 years. The mean duration since glaucoma diagnosis was 5.3 years (standard deviation 2.9 years). The mean visual acuity was 0.53 logMAR at baseline that improved to 0.23 at 6 months postoperatively. The mean baseline intraocular pressure was 21.1 mmHg, and this decreased significantly to 16.7 mmHg at 6 months (P < 0.01). The mean number of drops prescribed preoperatively was 2.3, which decreased to 0.6 at 6 months (P < 0.01). Sixty-six per cent of patients were drop-free at 6 months. One patient developed an hyphaema following surgery; no other adverse events were recorded. The iStent proved to be a safe and effective treatment for patients with open-angle glaucoma over our 6-month follow up period. Insertion resulted in a significant decrease in intraocular pressure as well as the number of topical antiglaucoma medications required for adequate intraocular pressure control. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.
Stabilizing detached Bridgman melt crystal growth: Proportional-integral feedback control
NASA Astrophysics Data System (ADS)
Yeckel, Andrew; Daoutidis, Prodromos; Derby, Jeffrey J.
2012-10-01
The dynamics, operability limits, and tuning of a proportional-integral feedback controller to stabilize detached vertical Bridgman crystal growth are analyzed using a capillary model of shape stability. The manipulated variable is the pressure difference between upper and lower vapor spaces, and the controlled variable is the gap width at the triple-phase line. Open and closed loop dynamics of step changes in these state variables are analyzed under both shape stable and shape unstable growth conditions. Effects of step changes in static contact angle and growth angle are also studied. Proportional and proportional-integral control can stabilize unstable growth, but only within tight operability limits imposed by the narrow range of allowed meniscus shapes. These limits are used to establish safe operating ranges of controller gain. Strong nonlinearity of the capillary model restricts the range of perturbations that can be stabilized, and under some circumstances, stabilizes a spurious operating state far from the set point. Stabilizing detachment at low growth angle proves difficult and becomes impossible at zero growth angle.
A new angle on microscopic suspension feeders near boundaries.
Pepper, Rachel E; Roper, Marcus; Ryu, Sangjin; Matsumoto, Nobuyoshi; Nagai, Moeto; Stone, Howard A
2013-10-15
Microscopic sessile suspension feeders are a critical component in aquatic ecosystems, acting as an intermediate trophic stage between bacteria and higher eukaryotic taxa. Because they live attached to boundaries, it has long been thought that recirculation of the feeding currents produced by sessile suspension feeders inhibits their ability to access fresh fluid. However, previous models for the feeding flows of these organisms assume that they feed by pushing fluid perpendicular to surfaces they live upon, whereas we observe that sessile suspension feeders often feed at an angle to these boundaries. Using experiments and calculations, we show that living suspension feeders (Vorticella) likely actively regulate the angle that they feed relative to a substratum. We then use theory and simulations to show that angled feeding increases nutrient and particle uptake by reducing the reprocessing of depleted water. This work resolves an open question of how a key class of suspension-feeding organisms escapes physical limitations associated with their sessile lifestyle. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.
Measurement of the dipole in the cross-correlation function of galaxies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaztanaga, Enrique; Bonvin, Camille; Hui, Lam, E-mail: gazta@ice.cat, E-mail: camille.bonvin@unige.ch, E-mail: lhui@astro.columbia.edu
It is usually assumed that in the linear regime the two-point correlation function of galaxies contains only a monopole, quadrupole and hexadecapole. Looking at cross-correlations between different populations of galaxies, this turns out not to be the case. In particular, the cross-correlations between a bright and a faint population of galaxies contain also a dipole. In this paper we present the first attempt to measure this dipole. We discuss the four types of effects that contribute to the dipole: relativistic distortions, evolution effect, wide-angle effect and large-angle effect. We show that the first three contributions are intrinsic anti-symmetric contributions thatmore » do not depend on the choice of angle used to measure the dipole. On the other hand the large-angle effect appears only if the angle chosen to extract the dipole breaks the symmetry of the problem. We show that the relativistic distortions, the evolution effect and the wide-angle effect are too small to be detected in the LOWz and CMASS sample of the BOSS survey. On the other hand with a specific combination of angles we are able to measure the large-angle effect with high significance. We emphasise that this large-angle dipole does not contain new physical information, since it is just a geometrical combination of the monopole and the quadrupole. However this measurement, which is in excellent agreement with theoretical predictions, validates our method for extracting the dipole from the two-point correlation function and it opens the way to the detection of relativistic effects in future surveys like e.g. DESI.« less
Baskaran, Mani; Ho, Sue-Wei; Tun, Tin A; How, Alicia C; Perera, Shamira A; Friedman, David S; Aung, Tin
2013-11-01
To evaluate the diagnostic performance of the iris-trabecular contact (ITC) index, a measure of the degree of angle-closure, using swept-source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) in comparison with gonioscopy. Prospective observational study. A total of 108 normal subjects and 32 subjects with angle-closure. The SSOCT 3-dimensional angle scans, which obtain radial scans for the entire circumference of the angle, were performed under dark conditions and analyzed using customized software by a single examiner masked to the subjects' clinical details. The ITC index was calculated as a percentage of the angle that was closed on SSOCT images. First-order agreement coefficient (AC1) statistics and area under the receiver operating characteristic curve (AUC) analyses were performed for angle-closure on the basis of the ITC index in comparison with gonioscopy. Angle-closure on gonioscopy was defined as nonvisibility of posterior trabecular meshwork for at least 2 quadrants. Agreement of the ITC index with gonioscopically defined angle-closure was assessed using the AC1 statistic. Study subjects were predominantly Chinese (95.7%) and female (70.7%), with a mean age of 59.2 (standard deviation, 8.9) years. The median ITC index was 15.24% for gonioscopically open-angle eyes (n = 108) and 48.5% for closed-angle eyes (n = 32) (P = 0.0001). The agreement for angle-closure based on ITC index cutoffs (>35% and ≥50%) and gonioscopic angle-closure was 0.699 and 0.718, respectively. The AUC for angle-closure detection using the ITC index was 0.83 (95% confidence interval, 0.76-0.89), with an ITC index >35% having a sensitivity of 71.9% and specificity of 84.3%. The ITC index is a summary measure of the circumferential extent of angle-closure as imaged with SSOCT. The index had moderate agreement and good diagnostic performance for angle-closure with gonioscopy as the reference standard. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Ng, Danny Siu-Chun; Ching, Ruby Hok-Ying; Chan, Clement Wai-Nang
2015-02-01
This study aims to determine the incidence of angle recession and glaucoma after traumatic microhyphema. Records of all patients treated for traumatic hyphema or microhyphema admitted to a district hospital throughout a 10-year period were retrospectively reviewed. Patients with open-globe injury were excluded. The following clinical features were recorded during patients' initial presentation and follow-up visits: Snellen visual acuity, examination with slit-lamp biomicroscopy, intraocular pressure (IOP), dilated fundoscopic examination, gonioscopic examination and treatment. For patients with IOP > 21 mmHg and requiring glaucoma medications, visual field tests were performed. A total of 97 patients met the study criteria, of which 62 had microhyphema and 35 had gross hyphema. Among the traumatic microhyphema patients, 47 (75.8 %) had angle recession and 4 (6.5 %) had glaucoma with mean follow-up of 49 months (range 6-98 months). A statistically significant association was found between angle recession greater than 180° and the occurrence of glaucoma (p < 0.01). No statistically significant differences were found between groups of patients with microhyphema or gross hyphema regarding the incidence of angle recession and glaucoma. The complications of angle recession and glaucoma in patients after traumatic microhyphema appear similar to those found in patients after gross hyphema.
Combined mode I stress intensity factors of slanted cracks
NASA Astrophysics Data System (ADS)
Ismail, A. E.; Rahman, M. Q. Abdul; Ghazali, M. Z. Mohd; Zulafif Rahim, M.; Rasidi Ibrahim, M.; Fahrul Hassan, Mohd; Nor, Nik Hisyamudin Muhd; Ariffin, A. M. T.; Zaini Yunos, Muhamad
2017-08-01
The solutions of stress intensity factors (SIFs) for slanted cracks in plain strain plate are hard to find in open literature. There are some previous solutions of SIFs available, however the studies are not completed except for the case of plain stress. The slanted cracks are modelled numerically using ANSYS finite element program. There are ten slanted angles and seven relative crack depths are used and the plate contains cracks which is assumed to fulfil the plain strain condition. The plate is then stressed under tension and bending loading and the SIFs are determined according to the displacement extrapolation method. Based on the numerical analysis, both slanted angles and relative crack length, a/L played an important role in determining the modes I and II SIFs. As expected the SIFs increased when a/L is increased. Under tension force, the introduction of slanted angles increased the SIFs. Further increment of angles reduced the SIFs however they are still higher than the SIFs obtained using normal cracks. Under bending moment, the present of slanted angles are significantly reduced the SIFs compared with the normal cracks. Under similar loading, mode II SIFs increased as function of a/L and slanted angles where increasing such parameters increasing the mode II SIFs.
Importance of Corneal Thickness
... Glaucoma Facts and Stats Glossary Symptoms of Open-Angle Glaucoma Types of Glaucoma » See All Articles Where the Money Goes Have a Question? Browse Our Q&A » Or e-mail us: question@ glaucoma.org For medical advice, contact your doctor. Our Newsletter Stay up-to-date ...
Does Your Child Have Glaucoma?
... Glaucoma Facts and Stats Glossary Symptoms of Open-Angle Glaucoma Types of Glaucoma » See All Articles Where the Money Goes Have a Question? Browse Our Q&A » Or e-mail us: question@ glaucoma.org For medical advice, contact your doctor. Our Newsletter Stay up-to-date ...
High-Absorptance Radiative Heat Sink
NASA Technical Reports Server (NTRS)
Cafferty, T.
1983-01-01
Absorptance of black-painted open-cell aluminum honeycomb improved by cutting honeycomb at angle or bias rather than straight across. This ensures honeycomb cavities escapes. At each reflection radiation attenuated by absorption. Applications include space-background simulators, space radiators, solar absorbers, and passive coolers for terrestrial use.
Hopkins, Jesse Bennett; Gillilan, Richard E; Skou, Soren
2017-10-01
BioXTAS RAW is a graphical-user-interface-based free open-source Python program for reduction and analysis of small-angle X-ray solution scattering (SAXS) data. The software is designed for biological SAXS data and enables creation and plotting of one-dimensional scattering profiles from two-dimensional detector images, standard data operations such as averaging and subtraction and analysis of radius of gyration and molecular weight, and advanced analysis such as calculation of inverse Fourier transforms and envelopes. It also allows easy processing of inline size-exclusion chromatography coupled SAXS data and data deconvolution using the evolving factor analysis method. It provides an alternative to closed-source programs such as Primus and ScÅtter for primary data analysis. Because it can calibrate, mask and integrate images it also provides an alternative to synchrotron beamline pipelines that scientists can install on their own computers and use both at home and at the beamline.
Mapping of a gene for autosomal dominant juvenile-onset open-angle glaucoma to chromosome 1 q
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richards, J.E.; Lichter, P.R.; Torrez, D.
1994-01-01
A large Caucasian family is presented, in which a juvenile-onset form of open-angle glaucoma is transmitted in an autosomal dominant fashion. Sixteen affected family members were identified from 31 at-risk individuals descended from the affected founder. Affected patients developed high intraocular pressures (sometimes >40 mm Hg) within the first 2 decades of life. Linkage analysis between the disease phenotype and 12 microsatellite repeat markers located on chromosome 1 q gave a maximum lod score of 8.38 at a recombination fraction of zero for marker D1S210. Analysis of recombinant haplotypes suggests a total inclusion region of about 14 cM between markersmore » D1S194 and D1S218 at 1q21-q31. This represents the second juvenile-glaucoma family, in which the disease has been mapped to the long arm of chromosome 1. 57 refs., 2 figs., 3 tabs.« less
Skalicky, Simon E; Ho, Ivan; Agar, Ashish; Bank, Allan
2012-07-01
To document cases of sustained elevation of intraocular pressure (IOP) while receiving intravitreal anti-vascular endothelial growth factor (VEGF) agents and subsequent management. A retrospective series of all cases managed by the authors and colleagues was performed. Six patients developed sustained elevated IOP; five received ranibizumab and one bevacizumab. Four received unilateral and two received bilateral injections. Two had preexisting primary open-angle glaucoma and one had pseudoexfoliative glaucoma, all with stable IOP prior to anti-VEGF treatment. Angles were open in all cases. Peak IOP averaged 43 mm Hg (range: 34 to 60 mm Hg). The mean number of injections preceding the IOP increase was 10 (range: 1 to 20). Four patients required trabeculectomy, one selective laser trabeculoplasty, and one multiple topical medications. A sustained increase in IOP requiring glaucoma filtering surgery is a rare but important treatment complication for patients receiving intravitreal anti-VEGF therapy, especially those with preexisting glaucoma or glaucoma risk factors. Copyright 2012, SLACK Incorporated.
A Semi-analytical Line Transfer (SALT) Model. II: The Effects of a Bi-conical Geometry
NASA Astrophysics Data System (ADS)
Carr, Cody; Scarlata, Claudia; Panagia, Nino; Henry, Alaina
2018-06-01
We generalize the semi-analytical line transfer model recently introduced by Scarlata & Panagia for modeling galactic outflows, to account for bi-conical geometries of various opening angles and orientations with respect to the line of sight to the observer, as well as generalized velocity fields. We model the absorption and emission component of the line profile resulting from resonant absorption in the bi-conical outflow. We show how the outflow geometry impacts the resulting line profile. We use simulated spectra with different geometries and velocity fields to study how well the outflow parameters can be recovered. We find that geometrical parameters (including the opening angle and the orientation) are always well recovered. The density and velocity field parameters are reliably recovered when both an absorption and an emission component are visible in the spectra. This condition implies that the velocity and density fields for narrow cones oriented perpendicular to the line of sight will remain unconstrained.
[Dry eye syndrome in patients with primary open-angle glaucoma].
Boyko, E V; Simakova, I L; Yakushev, D Yu; Ignat'ev, S A; Alekseev, I B; Mel'nikova, N V; Alyab'ev, M V; Mal'tsev, D S
2015-01-01
to determine the frequency and severity of dry eye syndrome (DES) in primary open-angle glaucoma (POAG) patients that are newly diagnosed or already receiving beta blocker instillation therapy. A total of 127 patients (190 eyes) with POAG were divided into two groups. Group 1 included 55 newly diagnosed patients (88 eyes), group 2-72 POAG patients (102 eyes) instilling timolol 0.5% twice daily into the affected eye. The control group included 20 patients (40 eyes) aged 60-88 years (73.6 ± 9.2 years on average) with early age-related cataract. DES was found in 69 POAG patients (79%) who was just starting their topical hypotensive therapy and 85 of those (84%) under treatment (p = 0.39). One should take into account when prescribing ocular hypotensive therapy that newly diagnosed POAG patients usually already suffer from a dry eye. The use of topical beta blockers that contain preservatives exacerbates dry eye signs and symptoms in these patients.
Vectorial diffraction properties of THz vortex Bessel beams.
Wu, Zhen; Wang, Xinke; Sun, Wenfeng; Feng, Shengfei; Han, Peng; Ye, Jiasheng; Yu, Yue; Zhang, Yan
2018-01-22
A vortex Bessel beam combines the merits of an optical vortex and a Bessel beam, including a spiral wave front and a non-diffractive feature, which has immense application potentials in optical trapping, optical fabrication, optical communications, and so on. Here, linearly and circularly polarized vortex Bessel beams in the terahertz (THz) frequency range are generated by utilizing a THz quarter wave plate, a spiral phase plate, and Teflon axicons with different opening angles. Taking advantage of a THz focal-plane imaging system, vectorial diffraction properties of the THz vortex Bessel beams are comprehensively characterized and discussed, including the transverse (Ex, Ey) and longitudinal (Ez) polarization components. The experimental phenomena are accurately simulated by adopting the vectorial Rayleigh diffraction integral. By varying the opening angle of the axicon, the characteristic parameters of these THz vortex Bessel beams are exhibited and compared, including the light spot size, the diffraction-free range, and the phase evolution process. This work provides the precise experimental and theoretical bases for the comprehension and application of a THz vortex Bessel beam.
Numerical modeling of local scour around hydraulic structure in sandy beds by dynamic mesh method
NASA Astrophysics Data System (ADS)
Fan, Fei; Liang, Bingchen; Bai, Yuchuan; Zhu, Zhixia; Zhu, Yanjun
2017-10-01
Local scour, a non-negligible factor in hydraulic engineering, endangers the safety of hydraulic structures. In this work, a numerical model for simulating local scour was constructed, based on the open source code computational fluid dynamics model OpenFOAM. We consider both the bedload and suspended load sediment transport in the scour model and adopt the dynamic mesh method to simulate the evolution of the bed elevation. We use the finite area method to project data between the three-dimensional flow model and the two-dimensional (2D) scour model. We also improved the 2D sand slide method and added it to the scour model to correct the bed bathymetry when the bed slope angle exceeds the angle of repose. Moreover, to validate our scour model, we conducted and compared the results of three experiments with those of the developed model. The validation results show that our developed model can reliably simulate local scour.
Fujimura, Tomomi; Umemura, Hiroyuki
2018-01-15
The present study describes the development and validation of a facial expression database comprising five different horizontal face angles in dynamic and static presentations. The database includes twelve expression types portrayed by eight Japanese models. This database was inspired by the dimensional and categorical model of emotions: surprise, fear, sadness, anger with open mouth, anger with closed mouth, disgust with open mouth, disgust with closed mouth, excitement, happiness, relaxation, sleepiness, and neutral (static only). The expressions were validated using emotion classification and Affect Grid rating tasks [Russell, Weiss, & Mendelsohn, 1989. Affect Grid: A single-item scale of pleasure and arousal. Journal of Personality and Social Psychology, 57(3), 493-502]. The results indicate that most of the expressions were recognised as the intended emotions and could systematically represent affective valence and arousal. Furthermore, face angle and facial motion information influenced emotion classification and valence and arousal ratings. Our database will be available online at the following URL. https://www.dh.aist.go.jp/database/face2017/ .
A common variant near TGFBR3 is associated with primary open angle glaucoma.
Li, Zheng; Allingham, R Rand; Nakano, Masakazu; Jia, Liyun; Chen, Yuhong; Ikeda, Yoko; Mani, Baskaran; Chen, Li-Jia; Kee, Changwon; Garway-Heath, David F; Sripriya, Sarangapani; Fuse, Nobuo; Abu-Amero, Khaled K; Huang, Chukai; Namburi, Prasanthi; Burdon, Kathryn; Perera, Shamira A; Gharahkhani, Puya; Lin, Ying; Ueno, Morio; Ozaki, Mineo; Mizoguchi, Takanori; Krishnadas, Subbiah Ramasamy; Osman, Essam A; Lee, Mei Chin; Chan, Anita S Y; Tajudin, Liza-Sharmini A; Do, Tan; Goncalves, Aurelien; Reynier, Pascal; Zhang, Hong; Bourne, Rupert; Goh, David; Broadway, David; Husain, Rahat; Negi, Anil K; Su, Daniel H; Ho, Ching-Lin; Blanco, Augusto Azuara; Leung, Christopher K S; Wong, Tina T; Yakub, Azhany; Liu, Yutao; Nongpiur, Monisha E; Han, Jong Chul; Hon, Do Nhu; Shantha, Balekudaru; Zhao, Bowen; Sang, Jinghong; Zhang, NiHong; Sato, Ryuichi; Yoshii, Kengo; Panda-Jonas, Songhomita; Ashley Koch, Allison E; Herndon, Leon W; Moroi, Sayoko E; Challa, Pratap; Foo, Jia Nee; Bei, Jin-Xin; Zeng, Yi-Xin; Simmons, Cameron P; Bich Chau, Tran Nguyen; Sharmila, Philomenadin Ferdinamarie; Chew, Merwyn; Lim, Blanche; Tam, Pansy O S; Chua, Elaine; Ng, Xiao Yu; Yong, Victor H K; Chong, Yaan Fun; Meah, Wee Yang; Vijayan, Saravanan; Seongsoo, Sohn; Xu, Wang; Teo, Yik Ying; Cooke Bailey, Jessica N; Kang, Jae H; Haines, Jonathan L; Cheng, Ching Yu; Saw, Seang-Mei; Tai, E-Shyong; Richards, Julia E; Ritch, Robert; Gaasterland, Douglas E; Pasquale, Louis R; Liu, Jianjun; Jonas, Jost B; Milea, Dan; George, Ronnie; Al-Obeidan, Saleh A; Mori, Kazuhiko; Macgregor, Stuart; Hewitt, Alex W; Girkin, Christopher A; Zhang, Mingzhi; Sundaresan, Periasamy; Vijaya, Lingam; Mackey, David A; Wong, Tien Yin; Craig, Jamie E; Sun, Xinghuai; Kinoshita, Shigeru; Wiggs, Janey L; Khor, Chiea-Chuen; Yang, Zhenglin; Pang, Chi Pui; Wang, Ningli; Hauser, Michael A; Tashiro, Kei; Aung, Tin; Vithana, Eranga N
2015-07-01
Primary open angle glaucoma (POAG), a major cause of blindness worldwide, is a complex disease with a significant genetic contribution. We performed Exome Array (Illumina) analysis on 3504 POAG cases and 9746 controls with replication of the most significant findings in 9173 POAG cases and 26 780 controls across 18 collections of Asian, African and European descent. Apart from confirming strong evidence of association at CDKN2B-AS1 (rs2157719 [G], odds ratio [OR] = 0.71, P = 2.81 × 10(-33)), we observed one SNP showing significant association to POAG (CDC7-TGFBR3 rs1192415, ORG-allele = 1.13, Pmeta = 1.60 × 10(-8)). This particular SNP has previously been shown to be strongly associated with optic disc area and vertical cup-to-disc ratio, which are regarded as glaucoma-related quantitative traits. Our study now extends this by directly implicating it in POAG disease pathogenesis. © The Author 2015. Published by Oxford University Press.
A common variant near TGFBR3 is associated with primary open angle glaucoma
Li, Zheng; Allingham, R. Rand; Nakano, Masakazu; Jia, Liyun; Chen, Yuhong; Ikeda, Yoko; Mani, Baskaran; Chen, Li-Jia; Kee, Changwon; Garway-Heath, David F.; Sripriya, Sarangapani; Fuse, Nobuo; Abu-Amero, Khaled K.; Huang, Chukai; Namburi, Prasanthi; Burdon, Kathryn; Perera, Shamira A.; Gharahkhani, Puya; Lin, Ying; Ueno, Morio; Ozaki, Mineo; Mizoguchi, Takanori; Krishnadas, Subbiah Ramasamy; Osman, Essam A.; Lee, Mei Chin; Chan, Anita S.Y.; Tajudin, Liza-Sharmini A.; Do, Tan; Goncalves, Aurelien; Reynier, Pascal; Zhang, Hong; Bourne, Rupert; Goh, David; Broadway, David; Husain, Rahat; Negi, Anil K.; Su, Daniel H; Ho, Ching-Lin; Blanco, Augusto Azuara; Leung, Christopher K.S.; Wong, Tina T.; Yakub, Azhany; Liu, Yutao; Nongpiur, Monisha E.; Han, Jong Chul; Hon, Do Nhu; Shantha, Balekudaru; Zhao, Bowen; Sang, Jinghong; Zhang, NiHong; Sato, Ryuichi; Yoshii, Kengo; Panda-Jonas, Songhomita; Ashley Koch, Allison E.; Herndon, Leon W.; Moroi, Sayoko E.; Challa, Pratap; Foo, Jia Nee; Bei, Jin-Xin; Zeng, Yi-Xin; Simmons, Cameron P.; Bich Chau, Tran Nguyen; Sharmila, Philomenadin Ferdinamarie; Chew, Merwyn; Lim, Blanche; Tam, Pansy O.S.; Chua, Elaine; Ng, Xiao Yu; Yong, Victor H.K.; Chong, Yaan Fun; Meah, Wee Yang; Vijayan, Saravanan; Seongsoo, Sohn; Xu, Wang; Teo, Yik Ying; Cooke Bailey, Jessica N.; Kang, Jae H.; Haines, Jonathan L.; Cheng, Ching Yu; Saw, Seang-Mei; Tai, E-Shyong; Richards, Julia E.; Ritch, Robert; Gaasterland, Douglas E.; Pasquale, Louis R.; Liu, Jianjun; Jonas, Jost B.; Milea, Dan; George, Ronnie; Al-Obeidan, Saleh A.; Mori, Kazuhiko; Macgregor, Stuart; Hewitt, Alex W.; Girkin, Christopher A.; Zhang, Mingzhi; Sundaresan, Periasamy; Vijaya, Lingam; Mackey, David A.; Wong, Tien Yin; Craig, Jamie E.; Sun, Xinghuai; Kinoshita, Shigeru; Wiggs, Janey L.; Khor, Chiea-Chuen; Yang, Zhenglin; Pang, Chi Pui; Wang, Ningli; Hauser, Michael A.; Tashiro, Kei; Aung, Tin; Vithana, Eranga N.
2015-01-01
Primary open angle glaucoma (POAG), a major cause of blindness worldwide, is a complex disease with a significant genetic contribution. We performed Exome Array (Illumina) analysis on 3504 POAG cases and 9746 controls with replication of the most significant findings in 9173 POAG cases and 26 780 controls across 18 collections of Asian, African and European descent. Apart from confirming strong evidence of association at CDKN2B-AS1 (rs2157719 [G], odds ratio [OR] = 0.71, P = 2.81 × 10−33), we observed one SNP showing significant association to POAG (CDC7–TGFBR3 rs1192415, ORG-allele = 1.13, Pmeta = 1.60 × 10−8). This particular SNP has previously been shown to be strongly associated with optic disc area and vertical cup-to-disc ratio, which are regarded as glaucoma-related quantitative traits. Our study now extends this by directly implicating it in POAG disease pathogenesis. PMID:25861811
Morning glory syndrome associated with primary open angle glaucoma--case report.
Bozić, Marija; Hentova-Senćanić, Paraskeva; Marković, Vujica; Marjanović, Ivan
2014-01-01
Morning glory syndrome (MGS) is a rare congenital optic disc anomaly, first reported in 1970. MGS is a nonprogressive and untreatable condition, which usually occurs as an isolated ocular anomaly, and can be associated with the increased incidence of nonrhegmatogenous retinal detachment, and also with strabismus, afferent pupillary defect, visual field defects, presence of hyaloids artery remnants, ciliary body cyst, congenital cataract, lid hemangioma and preretinal gliosis. We report a clinical case of MGS associated with primary open angle glaucoma. The use of sophisticated diagnostic tools, such as retinal tomography and visual field testing is limited if multiple eye conditions are present, since optic disc does not have "usual" appearance that can be analyzed according to standard statistical databases. In treating and follow up of glaucoma cases associated with other diseases and conditions that affect the appearance and function of the optic nerve head, sometimes the use of modern technological methods is limited due to difficult interpretation of the obtained results.
Flatness-Based Tracking Control and Nonlinear Observer for a Micro Aerial Quadcopter
NASA Astrophysics Data System (ADS)
Rivera, G.; Sawodny, O.
2010-09-01
This paper deals with the design of a nonlinear observer and a differential flat based path tracking controller for a mini aerial quadcopter. Taking into account that only the inertial coordinates and the yaw angle are available for measurements, it is shown, that the system is differentially flat, allowing a systematic design of a nonlinear tracking control in open and closed loop. A nonlinear observer is carried out to estimate the roll and pitch angle as well as all the linear and angular velocities. Finally the performance of the feedback controller and observer are illustrated in a computer simulation.
1993-01-15
through a pad of Celite into a flask equipped with a sidearm stopcock and the volume of the solution was not adjusted. Neopentyl lithium was...The resonance at 2.5 ppm (A) was irradiated and both this resonance and the resonance at 2.8 ppm (B) were integrated. An ethylene glycol temperature...angles for different side groups in model compound S (MM2 results, C3 = cyclopropyl, Np = neopentyl ). Figure 14. Values of torsion angle el at 10 fs
Schwartz, Mathew; Dixon, Philippe C
2018-01-01
The conventional gait model (CGM) is a widely used biomechanical model which has been validated over many years. The CGM relies on retro-reflective markers placed along anatomical landmarks, a static calibration pose, and subject measurements as inputs for joint angle calculations. While past literature has shown the possible errors caused by improper marker placement, studies on the effects of inaccurate subject measurements are lacking. Moreover, as many laboratories rely on the commercial version of the CGM, released as the Plug-in Gait (Vicon Motion Systems Ltd, Oxford, UK), integrating improvements into the CGM code is not easily accomplished. This paper introduces a Python implementation for the CGM, referred to as pyCGM, which is an open-source, easily modifiable, cross platform, and high performance computational implementation. The aims of pyCGM are to (1) reproduce joint kinematic outputs from the Vicon CGM and (2) be implemented in a parallel approach to allow integration on a high performance computer. The aims of this paper are to (1) demonstrate that pyCGM can systematically and efficiently examine the effect of subject measurements on joint angles and (2) be updated to include new calculation methods suggested in the literature. The results show that the calculated joint angles from pyCGM agree with Vicon CGM outputs, with a maximum lower body joint angle difference of less than 10-5 degrees. Through the hierarchical system, the ankle joint is the most vulnerable to subject measurement error. Leg length has the greatest effect on all joints as a percentage of measurement error. When compared to the errors previously found through inter-laboratory measurements, the impact of subject measurements is minimal, and researchers should rather focus on marker placement. Finally, we showed that code modifications can be performed to include improved hip, knee, and ankle joint centre estimations suggested in the existing literature. The pyCGM code is provided in open source format and available at https://github.com/cadop/pyCGM.
Dixon, Philippe C.
2018-01-01
The conventional gait model (CGM) is a widely used biomechanical model which has been validated over many years. The CGM relies on retro-reflective markers placed along anatomical landmarks, a static calibration pose, and subject measurements as inputs for joint angle calculations. While past literature has shown the possible errors caused by improper marker placement, studies on the effects of inaccurate subject measurements are lacking. Moreover, as many laboratories rely on the commercial version of the CGM, released as the Plug-in Gait (Vicon Motion Systems Ltd, Oxford, UK), integrating improvements into the CGM code is not easily accomplished. This paper introduces a Python implementation for the CGM, referred to as pyCGM, which is an open-source, easily modifiable, cross platform, and high performance computational implementation. The aims of pyCGM are to (1) reproduce joint kinematic outputs from the Vicon CGM and (2) be implemented in a parallel approach to allow integration on a high performance computer. The aims of this paper are to (1) demonstrate that pyCGM can systematically and efficiently examine the effect of subject measurements on joint angles and (2) be updated to include new calculation methods suggested in the literature. The results show that the calculated joint angles from pyCGM agree with Vicon CGM outputs, with a maximum lower body joint angle difference of less than 10-5 degrees. Through the hierarchical system, the ankle joint is the most vulnerable to subject measurement error. Leg length has the greatest effect on all joints as a percentage of measurement error. When compared to the errors previously found through inter-laboratory measurements, the impact of subject measurements is minimal, and researchers should rather focus on marker placement. Finally, we showed that code modifications can be performed to include improved hip, knee, and ankle joint centre estimations suggested in the existing literature. The pyCGM code is provided in open source format and available at https://github.com/cadop/pyCGM. PMID:29293565
The Development of an 8-inch by 8-inch Slotted Tunnel for Mach Numbers up to 1.28
NASA Technical Reports Server (NTRS)
Little, B. H., Jr.; Cubbage, James J., Jr.
1961-01-01
An 8-inch by 8-inch transonic tunnel model with test section slotted on two opposite walls was constructed in which particular emphasis -was given to the development of slot geometry, slot-flow reentry section, and short-diffuser configurations for good test-region flow and minimum total-pressure losses. Center-line static pressures through the test section, wall static pressures through the other parts of the tunnel, and total-pressure distributions at the inlet and exit stations of the diffuser were measured- With a slot length equal to two tunnel heights and 1/14 open-area-ratio slotted walls) a test region one tunnel height in length was obtained in which the deviation from the mean Mach number was less than +/- 0.01 up to Mach number 1.15. With 1/7 open-area-ratio slotted walls, a test region 0.84 tunnel heights in length with deviation less than +/- O.01 was obtained up to Mach number 1.26. Increasing the tunnel diffuser angle from 6.4 to 10 deg. increased pressure loss through the tunnel at Mach number 1.20 from 15 percent to 20 percent of the total pressure. The use of other diffusers with equivalent angles of 10 deg. but contoured so that the initial diffusion angle was less than 10 deg. and the final angle was 200 reduced the losses to as low as 16 percent. A method for changing the test-section Mach number rapidly by controlling the flow through a bypass line from the tunnel settling chamber to the slot-flow plenum chamber of the test section was very effective. The test-section Mach number was reduced approximately 5 percent in 1/8 second by bleeding into the test section a flow of air equal to 2 percent of the mainstream flow and 30 percent in 1/4 second with bleed flow equal to 10 percent of the mainstream flow. The rate of reduction was largely determined by the opening rate of the bleed-flow-control valve.
Türkmen, İsmail; Esenkaya, İrfan; Ünay, Koray; Türkmensoy, Fatih; Özkut, Afşar Timuçin
2014-01-01
Objectives: The purpose of this study is to evaluate the early results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for varus gonarthrosis and compare the results with the literatüre. Methods: The results of proximal tibia medial biplanar retrotubercle open wedge osteotomy for 23 knees of 22 patients with medial gonarthrosis were evaluated clinically and radiologically. Results: Twenty of the patients were female and two were male. Mean age of the patients was 56.24; mean boy mass index was 31.95 and preoperative HSS (Hospital for Special Surgery) score was 68.7. Mean tibiofemoral axis was 186.39° and mean Insall-Salvatti index value was 1.04 preoperatively. Mean follow up period was 30.19 months. Mean HSS score was 86.48, femorotibial anatomic axis angle was 175° and Insall-Salvati index value 1.06 during the last follow-up. The improvement of the HSS score and the femorotibial anatomic axis angle was statistically significant. However, the change in Insall Salvati index values was statistically insignificant. Nonfatal pulmonary embolus in 1 patient, and deep vein thrombosis that occured one year after the procedure in 1 patient, rhabdomyolysis in 1 patient and loss of correction (relapse) in 1 patient were encountered as complications. Conclusion: Our results show that proximal tibia medial biplanar retrotubercle open wedge osteotomy improves the frontal and sagittal plane deformities without changing the patellar tendon length. Hence, possible patellofemoral problems are prevented and the clinical results are improved.
Longitudinal Changes of Angle Configuration in Primary Angle-Closure Suspects
Jiang, Yuzhen; Chang, Dolly S.; Zhu, Haogang; Khawaja, Anthony P.; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M.
2015-01-01
Objective To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Design Longitudinal cohort study. Participants Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Methods Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Main Outcome Measures Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. Results No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (P<0.001 for all variables). Between 2 weeks and 18 months after LPI, a significant decrease in angle width was observed over time in treated eyes (P<0.001 for all variables), although the change over the first 5.5 months was not statistically significant for angle width measured under gonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8–1.6) in treated eyes and 1.6°/year (95% CI, 1.3–2.0) in untreated eyes (P<0.001). Conclusions Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the same time period. PMID:24835757
Akil, Handan; Dastiridou, Anna; Marion, Kenneth; Francis, Brian A; Chopra, Vikas
2017-03-23
First reported study to assess the effect of diurnal variation on anterior chamber angle measurements, as well as, to re-test the effects of lighting and angle-of-incidence variation on anterior chamber angle (ACA) measurements acquired by time-domain anterior segment optical coherence tomography (AS-OCT). A total of 30 eyes from 15 healthy, normal subjects underwent anterior chamber imaging using a Visante time-domain AS-OCT according to an IRB-approved protocol. For each eye, the inferior angle was imaged twice in the morning (8 am - 10 am) and then again in the afternoon (3 pm - 5 pm), under light meter-controlled conditions with ambient room lighting 'ON' and lights 'OFF', and at 5° angle of incidence increments. The ACA metrics measured for each eye were: angle opening distance (AOD, measured 500 and 750 μm anterior from scleral spur), the trabecular-iris-space area (TISA, measured 500 and 750 μm anterior from scleral spur), and scleral spur angle. Measurements were performed by masked, certified Reading Center graders using the Visante's Internal Measurement Tool. Differences in measurements between morning and afternoon, lighting variations, and angle of incidence were compared. Mean age of the participants was 31.2 years (range 23-58). Anterior chamber angle metrics did not differ significantly from morning to afternoon imaging, or when the angle of incidence was offset by 5° in either direction away from the inferior angle 6 o'clock position. (p-value 0.13-0.93). Angle metrics at the inferior corneal limbus, 6 o'clock position (IC270), with room lighting 'OFF', showed a significant decrease (p < 0.05) compared to room lighting 'ON'. There does not appear to be significant diurnal variation in AS-OCT parameters in normal individuals, but lighting conditions need to be strictly controlled since variation in lighting led to significant variability in AS-OCT parameters. No changes in ACA parameters were noted by varying the angle-of-incidence, which gives confidence in being able to perform longitudinal studies in approximately the same area (plus/minus 5° of original scan location).
NASA Astrophysics Data System (ADS)
Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto
2016-11-01
Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented
Injection-Sensitive Mechanics of Hydraulic Fracture Interaction with Discontinuities
NASA Astrophysics Data System (ADS)
Chuprakov, D.; Melchaeva, O.; Prioul, R.
2014-09-01
We develop a new analytical model, called OpenT, that solves the elasticity problem of a hydraulic fracture (HF) contact with a pre-existing discontinuity natural fracture (NF) and the condition for HF re-initiation at the NF. The model also accounts for fluid penetration into the permeable NFs. For any angle of fracture intersection, the elastic problem of a blunted dislocation discontinuity is solved for the opening and sliding generated at the discontinuity. The sites and orientations of a new tensile crack nucleation are determined based on a mixed stress- and energy-criterion. In the case of tilted fracture intersection, the finite offset of the new crack initiation point along the discontinuity is computed. We show that aside from known controlling parameters such stress contrast, cohesional and frictional properties of the NFs and angle of intersection, the fluid injection parameters such as the injection rate and the fluid viscosity are of first-order in the crossing behavior. The model is compared to three independent laboratory experiments, analytical criteria of Blanton, extended Renshaw-Pollard, as well as fully coupled numerical simulations. The relative computational efficiency of OpenT model (compared to the numerical models) makes the model attractive for implementation in modern engineering tools simulating hydraulic fracture propagation in naturally fractured environments.
Nave, Maryana I.; Gu, Yu; Karen Chen-Wiegart, Yu-Chen; ...
2017-01-05
We developed a special electrochemical cell enabling quantitative analysis andin situX-ray nanotomography of metal/electrolyte interfaces subject to corrosion. Using this cell and applying the nodoid model to describe menisci formed on tungsten wires during anodization, the evolution of the electrolyte surface tension, the concentration of reaction products, and the meniscus contact angle were studied. In contrast to the electrowetting effect, where the applied electric field decreases the contact angle of electrolytes, anodization of the tungsten wires increases the contact angle of the meniscus. Hence, an electric field favors dewetting rather than wetting of the newly formed surface. Finally, the discoveredmore » effect opens up new opportunities for the control of wetting phenomena and calls for the revision of existing theories of electrowetting.« less
Speciation Mapping of Environmental Samples Using XANES Imaging
Fast X-ray detectors with large solid angles and high dynamic ranges open the door to XANES imaging, in which millions of spectra are collected to image the speciation of metals at micrometre resolution, over areas up to several square centimetres. This paper explores how such mu...
NASA Astrophysics Data System (ADS)
ElJack, Eltayeb
2017-05-01
In the present work, large eddy simulations of the flow field around a NACA-0012 aerofoil near stall conditions are performed at a Reynolds number of 5 × 104, Mach number of 0.4, and at various angles of attack. The results show the following: at relatively low angles of attack, the bubble is present and intact; at moderate angles of attack, the laminar separation bubble bursts and generates a global low-frequency flow oscillation; and at relatively high angles of attack, the laminar separation bubble becomes an open bubble that leads the aerofoil into a full stall. Time histories of the aerodynamic coefficients showed that the low-frequency oscillation phenomenon and its associated physics are indeed captured in the simulations. The aerodynamic coefficients compared to previous and recent experimental data with acceptable accuracy. Spectral analysis identified a dominant low-frequency mode featuring the periodic separation and reattachment of the flow field. At angles of attack α ≤ 9.3°, the low-frequency mode featured bubble shedding rather than bubble bursting and reformation. The underlying mechanism behind the quasi-periodic self-sustained low-frequency flow oscillation is discussed in detail.
Head loss coefficient through sharp-edged orifices
NASA Astrophysics Data System (ADS)
Adam, Nicolas J.; De Cesare, Giovanni; Schleiss, Anton J.; Richard, Sylvain; Muench-Alligné, Cécile
2016-11-01
Nowadays, high-head power plants could increase their installed power capacity for many reasons, e.g. dam heightening, increase of their peak power capacity or refurbishment with new turbines. Frequently, due to several considerations, e.g. topographical or economical limitations, the existing surge tank cannot be extended to keep previous safety levels and efficiency. A valuable way to adapt these surge tanks is to place a throttle at their entrance like, for example, an orifice. The main effect of this adaptation is the introduction of head losses that reduce the extreme levels in the surge tank due to the mass oscillations resulting from a closure or opening of downstream discharge control. This research studies the influence of the edge angle of a ASME-standard orifice on the head losses. This angle introduces an asymmetrical behavior and influences head losses. Different angles are tested from 0° to the 67° (biggest angle possible for this configuration). The first step of this study is to determine experimentally the steady losses produced by orifice for several discharges. In the second step, a numerical model on ANSYS CFX is performed. Combining the two approaches, it is possible to understand and quantify the effect of the edge angle.
Johnson, Jared M; Im, Soohyun; Windl, Wolfgang; Hwang, Jinwoo
2017-01-01
We propose a new scanning transmission electron microscopy (STEM) technique that can realize the three-dimensional (3D) characterization of vacancies, lighter and heavier dopants with high precision. Using multislice STEM imaging and diffraction simulations of β-Ga 2 O 3 and SrTiO 3 , we show that selecting a small range of low scattering angles can make the contrast of the defect-containing atomic columns substantially more depth-dependent. The origin of the depth-dependence is the de-channeling of electrons due to the existence of a point defect in the atomic column, which creates extra "ripples" at low scattering angles. The highest contrast of the point defect can be achieved when the de-channeling signal is captured using the 20-40mrad detection angle range. The effect of sample thickness, crystal orientation, local strain, probe convergence angle, and experimental uncertainty to the depth-dependent contrast of the point defect will also be discussed. The proposed technique therefore opens new possibilities for highly precise 3D structural characterization of individual point defects in functional materials. Copyright © 2016 Elsevier B.V. All rights reserved.
A Missing Puzzle Piece in Murray's Law: the Optimal Angle of Junctions
NASA Astrophysics Data System (ADS)
Wang, Ruo-Qian; Taylor, Katherine; Winter, Amos G.; Global Engineering; Research Lab Team
2014-11-01
Branching flows are common in biological systems, such as the circulatory and respiratory systems of animals. The optimal radii of parent and daughter branches can be explained with Murray's law, which dictates that the sum of metabolic and pumping costs is minimized. Murray's Law can be used to determine the diameter of cascading channels but misses an important parameter: the angles of the branches. Past hydraulic studies have investigated the angle effect, but have not focused on whether this geometry follows Murray's Law; while a simple network optimization is able to show that at low Reynolds numbers a branch with a parent channel connecting to n equally distant channels obeying Murray's Law has a minimum total head loss with a branching angle θ, such that cos θ =n-2/3 , but it's not valid for high Reynolds number flows, which may experience separation and turbulence at the branches. The present study is focused on determining the optimal branch angle that complies with Murray's Law for moderate Reynolds numbers. Computational studies using Open FOAM and experiments using 3D printed branched channels will be presented. These results will be used to quantify the effect of Reynolds number on optimal branch geometry.
Ri, Y; Ballesteros, J A; Abrams, C K; Oh, S; Verselis, V K; Weinstein, H; Bargiello, T A
1999-01-01
We have explored the role of a proline residue located at position 87 in the second transmembrane segment (TM2) of gap junctions in the mechanism of voltage-dependent gating of connexin32 (Cx32). Substitution of this proline (denoted Cx32P87) with residues G, A, or V affects channel function in a progressive manner consistent with the expectation that a proline kink (PK) motif exists in the second transmembrane segment (TM2) of this connexin. Mutations of the preceding threonine residue T86 to S, A, C, V, N, or L shift the conductance-voltage relation of wild-type Cx32, such that the mutated channels close at smaller transjunctional voltages. The observed shift in voltage dependence is consistent with a reduction in the open probability of the mutant hemichannels at a transjunctional voltage (Vj) of 0 mV. In both cases in which kinetics were examined, the time constants for reaching steady state were faster for T86N and T86A than for wild type at comparable voltages, suggesting that the T86 mutations cause the energetic destabilization of the open state relative to the other states of the channel protein. The structural underpinnings of the observed effects were explored with Monte Carlo simulations. The conformational space of TM2 helices was found to differ for the T86A, V, N, and L mutants, which produce a less bent helix ( approximately 20 degrees bend angle) compared to the wild type, which has a approximately 37 degrees bend angle. The greater bend angle of the wild-type helix reflects the propensity of the T86 residue to hydrogen bond with the backbone carbonyl of amino acid residue I82. The relative differences in propensity for hydrogen bonding of the mutants relative to the wild-type threonine residue in the constructs we studied (T86A, V, N, L, S, and C) correlate with the shift in the conductance-voltage relation observed for T86 mutations. The data are consistent with a structural model in which the open conformation of the Cx32 channel corresponds to a more bent TM2 helix, and the closed conformation corresponds to a less bent helix. We propose that the modulation of the hydrogen-bonding potential of the T86 residue alters the bend angle of the PK motif and mediates conformational changes between open and closed channel states. PMID:10354417
Polaro–cryptic mirror of the lookdown as a biological model for open ocean camouflage
Brady, Parrish C.; Travis, Kort A.; Maginnis, Tara; Cummings, Molly E.
2013-01-01
With no object to hide behind in 3D space, the open ocean represents a challenging environment for camouflage. Conventional strategies for reflective crypsis (e.g., standard mirror) are effective against axially symmetric radiance fields associated with high solar altitudes, yet ineffective against asymmetric polarized radiance fields associated with low solar inclinations. Here we identify a biological model for polaro–crypsis. We measured the surface-reflectance Mueller matrix of live open ocean fish (lookdown, Selene vomer) and seagrass-dwelling fish (pinfish, Lagodon rhomboides) using polarization-imaging and modeling polarization camouflage for the open ocean. Lookdowns occupy the minimization basin of our polarization-contrast space, while pinfish and standard mirror measurements exhibit higher contrast values than optimal. The lookdown reflective strategy achieves significant gains in polaro–crypsis (up to 80%) in comparison with nonpolarization sensitive strategies, such as a vertical mirror. Lookdowns achieve polaro–crypsis across solar altitudes by varying reflective properties (described by 16 Mueller matrix elements mij) with incident illumination. Lookdowns preserve reflected polarization aligned with principle axes (dorsal–ventral and anterior–posterior, m22 = 0.64), while randomizing incident polarization 45° from principle axes (m33 = –0.05). These reflectance properties allow lookdowns to reflect the uniform degree and angle of polarization associated with high-noon conditions due to alignment of the principle axes and the sun, and reflect a more complex polarization pattern at asymmetrical light fields associated with lower solar elevations. Our results suggest that polaro–cryptic strategies vary by habitat, and require context-specific depolarization and angle alteration for effective concealment in the complex open ocean environment. PMID:23716701
Celli, Daniel; Gasperoni, Enrico; Deli, Roberto
2007-01-01
This case report describes the treatment of a patient with a Class II malocclusion with an anterior open bite. The patient, a girl 16 years of age, had a significant anteroposterior discrepancy and a high-angle tendency. Her face was convex, with competent lips. Intraorally she had an anterior open bite of 3 mm, space in the mandibular arch, and an overjet of 2 mm. High-pull headgear, anterior intermaxillary elastics, and appropriate wire bending were used to close the bite and to correct the anteroposterior dental relationship. Modification of a tongue thrust habit helped to correct this significant malocclusion and provided stability at 11 years posttreatment.
Oscillations of a sessile droplet in open air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Korenchenko, A. E., E-mail: korenchenko@physics.susu.ac.ru; Beskachko, V. P.
2013-11-15
The open system consisting of a sessile drop, a neutral gas, and a substrate is analyzed by numerical methods. The mode with constant contact angle is considered. The model takes into account evaporation from drop surface, free and forced convection in gas, buoyancy, and Marangoni effect in the liquid phase. It was established that every considered mechanical and thermodynamical disturbance of the system leads to the drop surface oscillations, and thus a drop in an open air oscillates almost inevitably. The displacement of the liquid-gas interface due to oscillations is analyzed in terms of its impact on the accuracy ofmore » measurement of the surface tension by sessile drop method.« less
Characteristic angles in the wetting of an angular region: deposit growth.
Popov, Yuri O; Witten, Thomas A
2003-09-01
Solids dispersed in a drying drop migrate to the (pinned) contact line. This migration is caused by outward flows driven by the loss of the solvent due to evaporation and by geometrical constraint that the drop maintains an equilibrium surface shape with a fixed boundary. Here, in continuation of our earlier paper, we theoretically investigate the evaporation rate, the flow field, and the rate of growth of the deposit patterns in a drop over an angular sector on a plane substrate. Asymptotic power laws near the vertex (as distance to the vertex goes to zero) are obtained. A hydrodynamic model of fluid flow near the singularity of the vertex is developed and the velocity field is obtained. The rate of the deposit growth near the contact line is found in two time regimes. The deposited mass falls off as a weak power gamma of distance close to the vertex and as a stronger power beta of distance further from the vertex. The power gamma depends only slightly on the opening angle alpha and stays roughly between -1/3 and 0. The power beta varies from -1 to 0 as the opening angle increases from 0 degrees to 180 degrees. At a given distance from the vertex, the deposited mass grows faster and faster with time, with the greatest increase in the growth rate occurring at the early stages of the drying process.
Spontaneous rise in open rectangular channels under gravity.
Thammanna Gurumurthy, Vignesh; Roisman, Ilia V; Tropea, Cameron; Garoff, Stephen
2018-05-17
Fluid movement in microfluidic devices, porous media, and textured surfaces involves coupled flows over the faces and corners of the media. Spontaneous wetting of simple grooved surfaces provides a model system to probe these flows. This numerical study investigates the spontaneous rise of a liquid in an array of open rectangular channels under gravity, using the Volume-of-Fluid method with adaptive mesh refinement. The rise is characterized by the meniscus height at the channel center, outer face and the interior and exterior corners. At lower contact angles and higher channel aspect ratios, the statics and dynamics of the rise in the channel center show little deviation with the classical model for capillarity, which ignores the existence of corners. For contact angles smaller than 45°, rivulets are formed in the interior corners and a cusp at the exterior corner. The rivulets at long times obey the one-third power law in time, with a weak dependence on the geometry. The cusp behaviour at the exterior corner transforms into a smooth meniscus when the capillary force is higher in the channel, even for contact angles smaller than 45°. The width of the outer face does not influence the capillary rise inside the channel, and the channel size does not influence the rise on the outer face. Copyright © 2018 Elsevier Inc. All rights reserved.
Rates of short-GRB afterglows in association with binary neutron star mergers
NASA Astrophysics Data System (ADS)
Saleem, M.; Pai, Archana; Misra, Kuntal; Resmi, L.; Arun, K. G.
2018-03-01
Assuming all binary neutron star (BNS) mergers produce short gamma-ray bursts, we combine the merger rates of BNS from population synthesis studies, the sensitivities of advanced gravitational wave (GW) interferometer networks, and of the electromagnetic (EM) facilities in various wavebands, to compute the detection rate of associated afterglows in these bands. Using the inclination angle measured from GWs as a proxy for the viewing angle and assuming a uniform distribution of jet opening angle between 3° and 30°, we generate light curves of the counterparts using the open access afterglow hydrodynamics package BOXFIT for X-ray, optical, and radio bands. For different EM detectors, we obtain the fraction of EM counterparts detectable in these three bands by imposing appropriate detection thresholds. In association with BNS mergers detected by five (three) detector networks of advanced GW interferometers, assuming a BNS merger rate of 0.6-774 Gpc-3 yr-1 from population synthesis models, we find the afterglow detection rates (per year) to be 0.04-53 (0.02-27), 0.03-36 (0.01-19), and 0.04-47 (0.02-25) in the X-ray, optical, and radio bands, respectively. Our rates represent maximum possible detections for the given BNS rate since we ignore effects of cadence and field of view in EM follow-up observations.
Level of education associated with ophthalmic diseases. The Beijing Eye Study.
Xu, Liang; Wang, Ya Xing; Jonas, Jost B
2010-01-01
To determine associations between educational level and ophthalmic diseases in Chinese. The population-based Beijing Eye Study, performed in 2006, enrolled 3,251 participants (age: 45+ years) out of 4,439 subjects invited to participate (response rate: 73.2%). The participants underwent an interview including questions concerning their educational level, and a detailed ophthalmic examination. Data on the level of education were available for 3,221 (99.1%) subjects, with 1,484 (46.1%) subjects living in the rural region. The mean age was 60.4 +/- 10.1 years (range: 45-89 years). In a multivariate analysis, a higher level of education was significantly associated with myopic refractive error, higher best-corrected visual acuity, lower degree of nuclear cataract, and lower prevalence of angle-closure glaucoma, and with the systemic parameters of lower age, male gender, urban region, taller body height, and lower body mass index. It was not significantly associated with intraocular pressure, amount of subcapsular cataract and cortical cataract, cataract surgery, and the prevalences of diabetes mellitus, retinal vein occlusions, chronic open-angle glaucoma, and age-related macular degeneration, and with the systemic parameters of fasting serum concentrations of glucose, high-density lipoproteins, low-density lipoproteins, cholesterol and triglycerides, systolic and diastolic blood pressure. In the Greater Beijing area, a higher level of education was associated with myopic refractive error, higher best-corrected visual acuity, and lower prevalence of nuclear cataract and angle-closure glaucoma, after adjusting for the systemic parameters of younger age, male gender, urban region, taller body height, lower body mass index less smoking and less alcohol consumption. Educational level was not significantly associated with intraocular pressure, cortical cataract, blood pressure, and frequencies of age-related macular degeneration, retinal vein occlusions and chronic open-angle glaucoma.
Lee, Pei-Jung; Liu, Catherine Jui-Ling.; Wojciechowski, Robert; Bailey-Wilson, Joan E.; Cheng, Ching-Yu
2010-01-01
Purpose To assess the correlations between retinal nerve fiber layer (RNFL) thickness measured with scanning laser polarimetry (SLP) and visual field (VF) sensitivity in primary open angle glaucoma (POAG) and primary angle-closure glaucoma (PACG). Design Prospective, comparative, observational cases series Methods Fifty patients with POAG and 56 with PACG were examined using SLP with variable corneal compensation (GDx VCC) and Humphrey VF analyzer between August 2005 and July 2006 at Taipei Veterans General Hospital. Correlations between RNFL thickness and VF sensitivity, expressed as mean sensitivity (MS) in both decibel (dB) and 1/Lambert (L) scales, were estimated by Spearman's rank correlation coefficient (rs) and multivariate median regression models (pseudo R2). The correlations were determined globally and for six RNFL sectors and their corresponding VF regions. Results The correlation between RNFL thickness and MS (in dB) was weaker in the PACG group (rs = 0.38, P = 0.004, pseudo R2 = 0.17) than in the POAG group (rs = 0.51, P <0.001, pseudo R2 = 0.31), but the difference in the magnitude of correlation was not significant (P = 0.42).With Bonferroni correction, the structure-function correlation was significant in the superotemporal (rs = 0.62), superonasal (rs = 0.56), inferonasal (rs = 0.53), and inferotemporal (rs = 0.50) sectors in the POAG group (all P <0.001), while it was significant only in the superotemporal (rs = 0.53) and inferotemporal (rs = 0.48) sectors in the PACG group (both P <0.001). The results were similar when MS was expressed as 1/L scale. Conclusions Both POAG and PACG eyes had moderate structure-function correlations using SLP. Compared to eyes with POAG, fewer RNFL sectors have significant structure-function correlations in eyes with PACG. PMID:20202618
NASA Astrophysics Data System (ADS)
Fan, Dazhi; Liu, Guili; Wei, Lin
2018-06-01
Based on the density functional theory, the effect of torsional deformation on the electronic structure and optical properties of boron nitride (BN)-doped graphene is studied by using the first-principles calculations. The band structure calculations show that the intrinsic graphene is a semi-metallic material with zero band gap and the torsional deformation has a large effect on its band gap, opening its band gap and turning it from the semi-metal to the medium band gap semiconductor. The doping of BN in graphene makes its band gap open and becomes a medium band gap semiconductor. When it is subjected to a torsional effect, it is found to have a weak influence on its band gap. In other words, the doping of BN makes the changes of the band gap of graphene no longer sensitive to torsional deformation. Optical properties show that the doping of BN leads to a significant decrease in the light absorption coefficient and reflectivity of the graphene at the characteristic peak and that of BN-doped graphene system is also weakened by torsional deformation at the characteristic peak. In the absorption spectrum, the absorption peaks of the doping system of the torsion angle of 2-20∘ are redshifted compared with that of the BN-doped system (the torsion angle is 0∘). In the reflection spectrum, the two reflection peaks are all redshifted relative to that of the BN-doped system (the torsion angle is 0∘) and when the torsion angle exceeds 12∘, the size relationship between the two peaks is interchanged. The results of this paper are of guiding significance for the study of graphene-based nanotube devices in terms of deformation.
Real-time inverse kinematics for the upper limb: a model-based algorithm using segment orientations.
Borbély, Bence J; Szolgay, Péter
2017-01-17
Model based analysis of human upper limb movements has key importance in understanding the motor control processes of our nervous system. Various simulation software packages have been developed over the years to perform model based analysis. These packages provide computationally intensive-and therefore off-line-solutions to calculate the anatomical joint angles from motion captured raw measurement data (also referred as inverse kinematics). In addition, recent developments in inertial motion sensing technology show that it may replace large, immobile and expensive optical systems with small, mobile and cheaper solutions in cases when a laboratory-free measurement setup is needed. The objective of the presented work is to extend the workflow of measurement and analysis of human arm movements with an algorithm that allows accurate and real-time estimation of anatomical joint angles for a widely used OpenSim upper limb kinematic model when inertial sensors are used for movement recording. The internal structure of the selected upper limb model is analyzed and used as the underlying platform for the development of the proposed algorithm. Based on this structure, a prototype marker set is constructed that facilitates the reconstruction of model-based joint angles using orientation data directly available from inertial measurement systems. The mathematical formulation of the reconstruction algorithm is presented along with the validation of the algorithm on various platforms, including embedded environments. Execution performance tables of the proposed algorithm show significant improvement on all tested platforms. Compared to OpenSim's Inverse Kinematics tool 50-15,000x speedup is achieved while maintaining numerical accuracy. The proposed algorithm is capable of real-time reconstruction of standardized anatomical joint angles even in embedded environments, establishing a new way for complex applications to take advantage of accurate and fast model-based inverse kinematics calculations.
Kinematics of Parsec-scale Jets of Gamma-Ray Blazars at 43 GHz within the VLBA-BU-BLAZAR Program
NASA Astrophysics Data System (ADS)
Jorstad, Svetlana G.; Marscher, Alan P.; Morozova, Daria A.; Troitsky, Ivan S.; Agudo, Iván; Casadio, Carolina; Foord, Adi; Gómez, José L.; MacDonald, Nicholas R.; Molina, Sol N.; Lähteenmäki, Anne; Tammi, Joni; Tornikoski, Merja
2017-09-01
We analyze the parsec-scale jet kinematics from 2007 June to 2013 January of a sample of γ-ray bright blazars monitored roughly monthly with the Very Long Baseline Array at 43 GHz. In a total of 1929 images, we measure apparent speeds of 252 emission knots in 21 quasars, 12 BL Lacertae objects (BLLacs), and 3 radio galaxies, ranging from 0.02c to 78c; 21% of the knots are quasi-stationary. Approximately one-third of the moving knots execute non-ballistic motions, with the quasars exhibiting acceleration along the jet within 5 pc (projected) of the core, and knots in BLLacs tending to decelerate near the core. Using the apparent speeds of the components and the timescales of variability from their light curves, we derive the physical parameters of 120 superluminal knots, including variability Doppler factors, Lorentz factors, and viewing angles. We estimate the half-opening angle of each jet based on the projected opening angle and scatter of intrinsic viewing angles of knots. We determine characteristic values of the physical parameters for each jet and active galactic nucleus class based on the range of values obtained for individual features. We calculate the intrinsic brightness temperatures of the cores, {T}{{b},{int}}{core}, at all epochs, finding that the radio galaxies usually maintain equipartition conditions in the cores, while ˜30% of {T}{{b},{int}}{core} measurements in the quasars and BLLacs deviate from equipartition values by a factor >10. This probably occurs during transient events connected with active states. In the Appendix, we briefly describe the behavior of each blazar during the period analyzed.
Huang, Ping; Shi, Yan; Wang, Xin; Liu, Mugen; Zhang, Chun
2014-09-01
To compare the interocular asymmetry of visual field loss in newly diagnosed normal-tension glaucoma (NTG), primary open-angle glaucoma (POAG), and chronic angle-closure glaucoma (CACG) patients. Visual field results of 117 newly diagnosed, treatment-naive glaucoma patients (42 NTG, 38 POAG, and 37 CACG) were studied retrospectively. The following 3 visual field defect parameters were used to evaluate the interocular asymmetry: (1) global indices; (2) local mean deviations (MDs) of 6 predefined visual field areas; and (3) stage designated by glaucoma staging system 2. The differences of the above parameters between the trial eye (the eye with greater MDs) and the fellow eye in each subject were defined as interocular asymmetry scores. Interocular asymmetry of visual field loss was presented in all the 3 groups (all P<0.05). CACG group had greater total MD interocular asymmetry score compared with the NTG and POAG groups (among groups, P=0.008; NTG vs. CACG, P=0.005; POAG vs. CACG, P=0.009). CACG also presented with significantly higher local MD interocular asymmetry scores at central, inferior, and temporal areas compared with those of the POAG group and at inferior area compared with that of NTG group. No significant difference in either total or local MDs was detected between NTG and POAG (all P>0.05). Interocular asymmetry scores of glaucoma staging system 2 had no significant difference among the 3 groups (P=0.068). All CACG, POAG, and NTG groups presented with interocular asymmetric visual field loss at the time of diagnosis. CACG had greater interocular asymmetry compared with NTG and POAG. No significant interocular asymmetry difference was observed between NTG and POAG.
Seet, Li-Fong; Narayanaswamy, Arun; Finger, Sharon N; Htoon, Hla M; Nongpiur, Monisha E; Toh, Li Zhen; Ho, Henrietta; Perera, Shamira A; Wong, Tina T
2016-11-01
This study aimed to evaluate differences in iris gene expression profiles between primary angle closure glaucoma (PACG) and primary open angle glaucoma (POAG) and their interaction with biometric characteristics. Prospective study. Thirty-five subjects with PACG and thirty-three subjects with POAG who required trabeculectomy were enrolled at the Singapore National Eye Centre, Singapore. Iris specimens, obtained by iridectomy, were analysed by real-time polymerase chain reaction for expression of type I collagen, vascular endothelial growth factor (VEGF)-A, -B and -C, as well as VEGF receptors (VEGFRs) 1 and 2. Anterior segment optical coherence tomography (ASOCT) imaging for biometric parameters, including anterior chamber depth (ACD), anterior chamber volume (ACV) and lens vault (LV), was also performed pre-operatively. Relative mRNA levels between PACG and POAG irises, biometric measurements, discriminant analyses using genes and biometric parameters. COL1A1, VEGFB, VEGFC and VEGFR2 mRNA expression was higher in PACG compared to POAG irises. LV, ACD and ACV were significantly different between the two subgroups. Discriminant analyses based on gene expression, biometric parameters or a combination of both gene expression and biometrics (LV and ACV), correctly classified 94.1%, 85.3% and 94.1% of the original PACG and POAG cases, respectively. The discriminant function combining genes and biometrics demonstrated the highest accuracy in cross-validated classification of the two glaucoma subtypes. Distinct iris gene expression supports the pathophysiological differences that exist between PACG and POAG. Biometric parameters can combine with iris gene expression to more accurately define PACG from POAG. © 2016 The Authors. Clinical & Experimental Ophthalmology published by John Wiley & Sons Australia, Ltd on behalf of Royal Australian and New Zealand College of Ophthalmologists.
Ko, Yu-Chieh; Hwang, De-Kuang; Chen, Wei-Ta; Lee, Ching-Chih; Liu, Catherine J
2016-01-01
To understand the impact of socioeconomic status (SES) on the diagnosis of primary open-angle glaucoma (POAG) and primary angle closure glaucoma (PACG) in Taiwan. Subjects with glaucoma were identified from the National Health Insurance Research Database of year 2006, which included one million randomly selected insurants. Individuals who had ≥4 ambulatory visits within one year which had the diagnosis code of POAG (ICD-9-CM 365.11 or 365.12) or PACG (365.23) and concurrent prescription of anti-glaucoma medication or surgery were selected. Individual SES was represented by monthly income calculated from the insurance premium. Neighborhood SES was defined based on neighborhood household income averages. Urbanization level of habitation was categorized into 3 levels. The odds ratio of having POAG or PACG in subjects with different SES was evaluated by using multiple logistic regression analysis. In total, 752 and 561 subjects with POAG and PACG, respectively, who were treated on a regular basis, were identified. The diagnosis of glaucoma was affected by age, gender, frequency of healthcare utilization, individual SES, and urbanization level of habitation. With the adjustment of age, gender, healthcare utilization, neighborhood SES and level of urbanization, subjects with lower income were more likely to be diagnosed as PACG, but less likely as POAG. Subjects with more frequent healthcare utilization were more likely to be diagnosed with glaucoma. Subjects with low SES were more susceptible to PACG, but subjects with high SES were more likely to be diagnosed as POAG. This information is useful for the design and target participant setting in glaucoma education and screening campaign to maximize the efficacy of limited resources in preventing glaucoma blindness.
Role of ocular convergence in the Romberg quotient.
Lê, Thanh-Thuan; Kapoula, Zoï
2008-04-01
The Romberg test generally shows that postural stability is better with eyes open than eyes closed; the Romberg quotient (RQ) is generally 2.5. This study examines the possible role of vergence angle on the RQ. Eighteen young (25.3+/-2.7 years) and 17 old (61.6+/-4.4 years) subjects were required to fixate a target at 40 cm or at 200 cm inducing different vergence angle (i.e. 8.6 degrees and 1.7 degrees, respectively) either with eyes open or closed. Postural stability of subjects was measured with force platform (TechnoConcept). The RQ was about 2 at 40 cm but dropped to 1 at 200 cm. In a second experiment, 15 subjects (26.7+/-5.5 years) run the Romberg test with eye movement measures (Chronos). Subjects were required to fixate a target placed at 20 cm, 40 cm, 90 cm, 200 cm or 350 cm either in light or in dark. The RQ at 20 cm and 40 cm was close to 2 and dropped to 1 at 90 cm and beyond. In parallel, the vergence angle at 20 cm and 40 cm changed significantly between light and dark, while at 90 cm and beyond it was stable (about 2 degrees both in light and dark). The distance had a significant effect on the co-variance between the RQ based on the anterior-posterior sway, and the change of vergence angle. We suggest different ways of control of posture according to the viewing distance: at near distance and in the light, the CNS uses vision coupled with oculo-motor convergence signals (efferent and afferent) leading to high RQ; at intermediate and far distances, it would use mostly internal signals (vestibular, proprioceptive, somatosensory), and similarly in the light and in the dark.
Qin, Bing; Francis, Brian A.; Li, Yan; Tang, Maolong; Zhang, Xinbo; Jiang, Chunhui; Cleary, Catherine; Huang, David
2012-01-01
Purpose To use Fourier-domain optical coherence tomography (OCT) to measure the angle opening distance at Schwalbe's line (AOD-SL) and determine its value in anterior chamber angle assessment. Methods Horizontal scans of the nasal and temporal anterior chamber angles in glaucoma subjects were performed by 830 nm wavelength Fourier-domain OCT. Images were graded by two ophthalmologists who assessed the visibility of Schwalbe’s line (SL), anterior limbus (AL), scleral spur (SS), and angle recess (AR). AOD-SL was measured with computer calipers. SL was manually identified by the termination of the corneal endothelium. Gonioscopy was used to classify anterior chamber angles according to a modified Shaffer system. Spearman's rho analysis was performed to assess correlation between AOD-SL and modified Shaffer grade. A cut-off value of AOD-SL for diagnosing occludable angles (modified Shaffer grade ≤1) was determined by receiver operating characteristic (ROC) analyses. Results Thirty-five glaucoma subjects (65 eyes) were enrolled. SL, AL, AR, and SS were visible by OCT in 97.7%, 99.2%, 87.3%, and 80.8% of eyes, respectively. Nasal and temporal AOD-SLs were 322.6 ± 200.2 µm and 341.4 ± 197.4 µm, respectively. Correlation coefficients between AOD-SL and modified Shaffer grade were 0.80 (nasal) and 0.81 (temporal). The diagnostic cut-off value of AOD-SL for occludable angles was 290 µm. The areas under the ROC curve, sensitivity, specificity values were 0.90, 0.80, 0.87 (nasal) and 0.90, 0.85, 0.77 (temporal). Conclusions The measurement of AOD-SL by Fourier-domain OCT is highly correlated with gonioscopy and may be a useful noncontact method of assessing angle closure risk. PMID:22827999
Relationship between iris surface features and angle width in Asian eyes.
Sidhartha, Elizabeth; Nongpiur, Monisha Esther; Cheung, Carol Y; He, Mingguang; Wong, Tien Yin; Aung, Tin; Cheng, Ching-Yu
2014-10-23
To examine the associations between iris surface features with anterior chamber angle width in Asian eyes. In this prospective cross-sectional study, we recruited 600 subjects from a large population-based study, the Singapore Epidemiology of Eye Diseases (SEED) study. We obtained standardized digital slit-lamp iris photographs and graded the iris crypts (by number and size), furrows (by number and circumferential extent), and color (higher grade denoting darker iris). Vertical and horizontal cross-sections of anterior chamber were imaged using anterior segment optical coherence tomography. Angle opening distance (AOD), angle recess area (ARA), and trabecular-iris space area (TISA) were measured using customized software. Associations of the angle width with the iris surface features in the subject's right eyes were assessed using linear regression analysis. A total of 464 eyes of the 464 subjects (mean age: 57.5 ± 8.6 years) had complete and gradable data for crypts and color, and 423 eyes had gradable data for furrows. After adjustment for age, sex, ethnicity, pupil size, and corneal arcus, higher crypt grade was independently associated with wider AOD750 (β [change in angle width per grade higher] = 0.018, P = 0.023), ARA750 (β = 0.022, P = 0.049), and TISA750 (β = 0.011, P = 0.019), and darker iris was associated narrower ARA750 (β = -0.025, P = 0.044) and TISA750 (β = -0.013, P = 0.011). Iris surface features, assessed and measured from slit-lamp photographs, correlated well with anterior chamber angle width; irises with more crypts and lighter color were associated with wider angle. These findings may provide another imaging modality to assess angle closure risk based on iris surface features. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Kyari, Fatima; Entekume, Gabriel; Rabiu, Mansur; Spry, Paul; Wormald, Richard; Nolan, Winifred; Murthy, Gudlavalleti V S; Gilbert, Clare E
2015-12-12
Glaucoma is the leading cause of irreversible blindness worldwide. There tends to be a lower reporting of glaucoma in Africa compared to other blinding conditions in global burden data. Research findings of glaucoma in Nigeria will significantly increase our understanding of glaucoma in Nigeria, in people of the West African diaspora and similar population groups. We determined the prevalence and types of glaucoma in Nigeria from the Nigeria National Blindness and Visual Impairment cross-sectional Survey of adults aged ≥40 years. Multistage stratified cluster random sampling with probability-proportional-to-size procedures were used to select a nationally representative sample of 15,027 persons aged ≥40 years. Participants had logMAR visual acuity measurement, FDT visual function testing, autorefraction, A-scan biometry and optic disc assessment. Participants with visual acuity of worse than 6/12 or suspicious optic discs had detailed examination including Goldmann applanation tonometry, gonioscopy and fundus photography. Disc images were graded by Moorfields Eye Hospital Reading Centre. Glaucoma was defined using International Society of Geographical and Epidemiological Ophthalmology criteria; and classified into primary open-angle or primary angle-closure or secondary glaucoma. Diagnosis of glaucoma was based on ISGEO classification. The type of glaucoma was determined by gonioscopy. A total of 13,591 participants in 305 clusters were examined (response rate 90.4 %). Optic disc grading was available for 25,289 (93 %) eyes of 13,081 (96 %) participants. There were 682 participants with glaucoma; a prevalence of 5.02 % (95 % CI 4.60-5.47). Among those with definite primary glaucoma that had gonioscopy (n = 243), open-angle glaucoma was more common (86 %) than angle-closure glaucoma (14 %). 8 % of glaucoma was secondary with the commonest causes being couching (38 %), trauma (21 %) and uveitis (19 %). Only 5.6 % (38/682) of participants with glaucoma knew they had the condition. One in every 5 persons with glaucoma (136;20 %) was blind i.e., visual acuity worse than 3/60. Nigeria has a high prevalence of glaucoma which is largely open-angle glaucoma. A high proportion of those affected are blind. Secondary glaucoma was mostly as a consequence of procedures for cataract. Public health control strategies and high quality glaucoma care service will be required to reduce morbidity and blindness from glaucoma.
Tycho 2: A Proxy Application for Kinetic Transport Sweeps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garrett, Charles Kristopher; Warsa, James S.
2016-09-14
Tycho 2 is a proxy application that implements discrete ordinates (SN) kinetic transport sweeps on unstructured, 3D, tetrahedral meshes. It has been designed to be small and require minimal dependencies to make collaboration and experimentation as easy as possible. Tycho 2 has been released as open source software. The software is currently in a beta release with plans for a stable release (version 1.0) before the end of the year. The code is parallelized via MPI across spatial cells and OpenMP across angles. Currently, several parallelization algorithms are implemented.
Nearfield Unsteady Pressures at Cruise Mach Numbers for a Model Scale Counter-Rotation Open Rotor
NASA Technical Reports Server (NTRS)
Stephens, David B.
2012-01-01
An open rotor experiment was conducted at cruise Mach numbers and the unsteady pressure in the nearfield was measured. The system included extensive performance measurements, which can help provide insight into the noise generating mechanisms in the absence of flow measurements. A set of data acquired at a constant blade pitch angle but various rotor speeds was examined. The tone levels generated by the front and rear rotor were found to be nearly equal when the thrust was evenly balanced between rotors.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to... dimension of the apple determined by passing the apple through a round opening in any position. U.S...
Code of Federal Regulations, 2014 CFR
2014-01-01
..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to... dimension of the apple determined by passing the apple through a round opening in any position. U.S...
Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin
2009-05-01
To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P < .001; gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P < .001; McNemar test). Of the 51 eyes with a closed ACA on gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.
SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ju, S; Hong, C; Kim, M
Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed withoutmore » the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.« less
Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy
Balakrishna, Nagalla
2017-01-01
Aim To evaluate the configuration of the anterior chamber angle quantitatively and study the morphological changes in the eye with ultrasound biomicroscopy (UBM) in primary angle closure glaucoma (PACG) patients after laser peripheral iridotomy (LPI). Materials and methods A total of 185 eyes of 185 PACG patients post-LPI and 126 eyes of 126 normal subjects were included in this prospective study. All subjects underwent complete ophthalmic evaluation, A-scan biometry, and UBM. The anterior segment and angle parameters were measured quantitatively and compared in both groups using Student’s t-test. Results The PACG patients had shorter axial length, shallower central anterior chamber depth anterior chamber depth (ACD), and anteriorly located lens when compared with normal subjects. Trabecular iris angle (TIA) was significantly narrow (5.73 ± 7.76°) in patients with PACG when compared with normal subjects (23.75 ± 9.38°). The angle opening distance at 500 pm from scleral spur (AOD 500), trabecular-ciliary process distance (TCPD), iris-ciliary process distance (ICPD), and iris-zonule distance (IZD) were significantly shorter in patients with PACG than in normal subjects (p < 0.0001). The iris lens angle (ILA), scleral-iris angle (SIA), and scleral-ciliary process angle (SCPA) were significantly narrower in patients with PACG than in normal subjects (p < 0.0001). The iris-lens contact distance (ILCD) was greater in PACG group than in normal (p = 0.001). Plateau iris was seen in 57/185 (30.8%) of the eyes. Anterior positioned ciliary processes were seen in 130/185 eyes (70.3%) of eyes. Conclusion In PACG patients, persistent apposition angle closure is common even after LPI, which could be due to anterior rotation of ciliary body and plateau iris and overcrowding of anterior segment due to shorter axial length and relative anterior lens position. How to cite this article: Mansoori T, Balakrishna N. Anterior Segment Morphology in Primary Angle Closure Glaucoma using Ultrasound Biomicroscopy. J Curr Glaucoma Pract 2017;11(3):86-91. PMID:29151682
Theologis, Alexander A; Mundis, Gregory M; Nguyen, Stacie; Okonkwo, David O; Mummaneni, Praveen V; Smith, Justin S; Shaffrey, Christopher I; Fessler, Richard; Bess, Shay; Schwab, Frank; Diebo, Bassel G; Burton, Douglas; Hart, Robert; Deviren, Vedat; Ames, Christopher
2017-02-01
OBJECTIVE The aim of this study was to evaluate the utility of supplementing long thoracolumbar posterior instrumented fusion (posterior spinal fusion, PSF) with lateral interbody fusion (LIF) of the lumbar/thoracolumbar coronal curve apex in adult spinal deformity (ASD). METHODS Two multicenter databases were evaluated. Adults who had undergone multilevel LIF of the coronal curve apex in addition to PSF with L5-S1 interbody fusion (LS+Apex group) were matched by number of posterior levels fused with patients who had undergone PSF with L5-S1 interbody fusion without LIF (LS-Only group). All patients had at least 2 years of follow-up. Percutaneous PSF and 3-column osteotomy (3CO) were excluded. Demographics, perioperative details, radiographic spinal deformity measurements, and HRQoL data were analyzed. RESULTS Thirty-two patients were matched (LS+Apex: 16; LS: 16) (6 men, 26 women; mean age 63 ± 10 years). Overall, the average values for measures of deformity were as follows: Cobb angle > 40°, sagittal vertical axis (SVA) > 6 cm, pelvic tilt (PT) > 25°, and mismatch between pelvic incidence (PI) and lumbar lordosis (LL) > 15°. There were no significant intergroup differences in preoperative radiographic parameters, although patients in the LS+Apex group had greater Cobb angles and less LL. Patients in the LS+Apex group had significantly more anterior levels fused (4.6 vs 1), longer operative times (859 vs 379 minutes), and longer length of stay (12 vs 7.5 days) (all p < 0.01). For patients in the LS+Apex group, Cobb angle, pelvic tilt (PT), lumbar lordosis (LL), PI-LL (lumbopelvic mismatch), Oswestry Disability Index (ODI) scores, and visual analog scale (VAS) scores for back and leg pain improved significantly (p < 0.05). For patients in the LS-Only group, there were significant improvements in Cobb angle, ODI score, and VAS scores for back and leg pain. The LS+Apex group had better correction of Cobb angles (56% vs 33%, p = 0.02), SVA (43% vs 5%, p = 0.46), LL (62% vs 13%, p = 0.35), and PI-LL (68% vs 33%, p = 0.32). Despite more LS+Apex patients having major complications (56% vs 13%; p = 0.02) and postoperative leg weakness (31% vs 6%, p = 0.07), there were no intergroup differences in 2-year outcomes. CONCLUSIONS Long open posterior instrumented fusion with or without multilevel LIF is used to treat a variety of coronal and sagittal adult thoracolumbar deformities. The addition of multilevel LIF to open PSF with L5-S1 interbody support in this small cohort was often used in more severe coronal and/or lumbopelvic sagittal deformities and offered better correction of major Cobb angles, lumbopelvic parameters, and SVA than posterior-only operations. As these advantages came at the expense of more major complications, more leg weakness, greater blood loss, and longer operative times and hospital stays without an improvement in 2-year outcomes, future investigations should aim to more clearly define deformities that warrant the addition of multilevel LIF to open PSF and L5-S1 interbody fusion.
Jiang, Yuzhen; Chang, Dolly S; Zhu, Haogang; Khawaja, Anthony P; Aung, Tin; Huang, Shengsong; Chen, Qianyun; Munoz, Beatriz; Grossi, Carlota M; He, Mingguang; Friedman, David S; Foster, Paul J
2014-09-01
To determine longitudinal changes in angle configuration in the eyes of primary angle-closure suspects (PACS) treated by laser peripheral iridotomy (LPI) and in untreated fellow eyes. Longitudinal cohort study. Primary angle-closure suspects aged 50 to 70 years were enrolled in a randomized, controlled clinical trial. Each participant was treated by LPI in 1 randomly selected eye, with the fellow eye serving as a control. Angle width was assessed in a masked fashion using gonioscopy and anterior segment optical coherence tomography (AS-OCT) before and at 2 weeks, 6 months, and 18 months after LPI. Angle width in degrees was calculated from Shaffer grades assessed under static gonioscopy. Angle configuration was also evaluated using angle opening distance (AOD250, AOD500, AOD750), trabecular-iris space area (TISA500, TISA750), and angle recess area (ARA) measured in AS-OCT images. No significant difference was found in baseline measures of angle configuration between treated and untreated eyes. At 2 weeks after LPI, the drainage angle on gonioscopy widened from a mean of 13.5° at baseline to a mean of 25.7° in treated eyes, which was also confirmed by significant increases in all AS-OCT angle width measures (P<0.001 for all variables). Between 2 weeks and 18 months after LPI, a significant decrease in angle width was observed over time in treated eyes (P<0.001 for all variables), although the change over the first 5.5 months was not statistically significant for angle width measured under gonioscopy (P = 0.18), AOD250 (P = 0.167) and ARA (P = 0.83). In untreated eyes, angle width consistently decreased across all follow-up visits after LPI, with a more rapid longitudinal decrease compared with treated eyes (P values for all variables ≤0.003). The annual rate of change in angle width was equivalent to 1.2°/year (95% confidence interval [CI], 0.8-1.6) in treated eyes and 1.6°/year (95% CI, 1.3-2.0) in untreated eyes (P<0.001). Angle width of treated eyes increased markedly after LPI, remained stable for 6 months, and then decreased significantly by 18 months after LPI. Untreated eyes experienced a more consistent and rapid decrease in angle width over the same time period. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Leasure, Jessica O; Peck, Jeffrey N; Villamil, Armando; Fiore, Kara L; Tano, Cheryl A
2016-11-23
To evaluate the inter- and intra-observer variability in measurement of the angle of lateral opening (ALO) and version angle measurement using digital radiography and computed tomography (CT). Each hemipelvis was implanted with a cementless acetabular cup. Ventrodorsal and mediolateral radiographs were made of each pelvis, followed by CT imaging. After removal of the first cup, the pelves were implanted with an acetabular cup in the contralateral acetabulum and imaging was repeated. Three surgeons measured the ALO and version angles three times for each cup from the mediolateral radiographic projection. The same measurements were made using three-dimensional multiplanar reconstructions from CT images. Two anatomical axes were used to measure pelvic inclination in the sagittal plane, resulting in six measurements per cup. Two-way repeated measures analysis of variance evaluated inter- and intra-observer repeatability for radiographic and CT-based measurements. Version angle based on radiographic measurement did not differ within surgeons (p = 0.433), but differed between surgeons (p <0.001). Radiographic measurement of ALO differed within surgeons (p = 0.006) but not between surgeons (p = 0.989). The ALO and version angle measured on CT images did not differ with or between surgeons. Assessment of inter- and intra-observer measurement of ALO and version angle was more reproducible using CT images than conventional mediolateral radiography for a Zurich cementless acetabular cup.
Gold coated metal nanostructures grown by glancing angle deposition and pulsed electroplating
NASA Astrophysics Data System (ADS)
Grüner, Christoph; Reeck, Pascal; Jacobs, Paul-Philipp; Liedtke, Susann; Lotnyk, Andriy; Rauschenbach, Bernd
2018-05-01
Nickel based nanostructures are grown by glancing angle deposition (GLAD) on flat and pre-patterned substrates. These fabricated porous thin films were subsequently coated by pulsed electroplating with gold. The morphology and conformity of the gold coating were investigated by scanning electron microscopy and X-ray diffraction. Controlled growth of closed gold layers on the nanostructures could be achieved, while the open-pore structure of the nanosculptured thin films was preserved. Such gold coated nanostructures are a candidate for optical sensing and catalysis applications. The demonstrated method can be applied for numerous material combinations, allowing to provide GLAD thin films with new surface properties.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deng, Mingsen; Guizhou Provincial Key Laboratory of Computational Nano-Material Science, Institute of Applied Physics, Guizhou Normal College, Guiyang, 550018; Ye, Gui
The probe of flexible molecular conformation is crucial for the electric application of molecular systems. We have developed a theoretical procedure to analyze the couplings of molecular local vibrations with the electron transportation process, which enables us to evaluate the structural fingerprints of some vibrational modes in the inelastic electron tunneling spectroscopy (IETS). Based on a model molecule of Bis-(4-mercaptophenyl)-ether with a flexible center angle, we have revealed and validated a simple mathematical relationship between IETS signals and molecular angles. Our results might open a route to quantitatively measure key geometrical parameters of molecular junctions, which helps to achieve precisemore » control of molecular devices.« less
Thermally Tunable Hydrogels Displaying Angle-Independent Structural Colors.
Ohtsuka, Yumiko; Seki, Takahiro; Takeoka, Yukikazu
2015-12-14
We report the preparation of thermally tunable hydrogels displaying angle-independent structural colors. The porous structures were formed with short-range order using colloidal amorphous array templates and a small amount of carbon black (CB). The resultant porous hydrogels prepared using colloidal amorphous arrays without CB appeared white, whereas the hydrogels with CB revealed bright structural colors. The brightly colored hydrogels rapidly changed hues in a reversible manner, and the hues varied widely depending on the water temperature. Moreover, the structural colors were angle-independent under diffusive lighting because of the isotropic nanostructure generated from the colloidal amorphous arrays. © 2015 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA. This is an open access article under the terms of the Creative Commons Attribution Non-Commercial NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
NASA Technical Reports Server (NTRS)
Farassat, F.
1984-01-01
A simple mathematical model of a stationary source distribution for the supersonic-propeller noise-prediction formula of Farassat (1983) is developed to test the validity of the formula solutions. The conventional thickness source term is used in place of the Isom thickness formula; the relative importance of the line and surface integrals in the solutions is evaluated; and the numerical results are compared with those obtained with a conventional retarded-time solution in tables. Good agreement is obtained over elevation angles from 10 to 90 deg, and the line-integral contribution is found to be significant at all elevation angles and of the same order of magnitude as the surface-integral contribution at angles less than 30 deg. The amplitude-normalized directivity patterns for the four cases computed (x = 1.5 or 10; k = 5.0 or 50) are presented graphically.
NASA Astrophysics Data System (ADS)
Behr, Bradford
2005-09-01
Tycho Brahe lived and worked in the late 1500s before the telescope was invented. He made highly accurate observations of the positions of planets, stars, and comets using large angle-measuring devices of his own design. You can use his techniques to observe the sky as well. For example, the degree, a common unit of measurement in astronomy, can be measured by holding your fist at arm's length up to the sky. Open your fist and observe the distance across the sky covered by the width of your pinky fingernail. That is, roughly, a degree! After some practice, and knowing that one degree equals four minutes, you can measure elapsed time by measuring the angle of the distance that the Moon appears to have moved and multiplying that number by four. You can also figure distances and sizes of things. These are not precise measurements, but rough estimates that can give you a "close-enough" answer.
Three-dimensional super-resolved live cell imaging through polarized multi-angle TIRF.
Zheng, Cheng; Zhao, Guangyuan; Liu, Wenjie; Chen, Youhua; Zhang, Zhimin; Jin, Luhong; Xu, Yingke; Kuang, Cuifang; Liu, Xu
2018-04-01
Measuring three-dimensional nanoscale cellular structures is challenging, especially when the structure is dynamic. Owing to the informative total internal reflection fluorescence (TIRF) imaging under varied illumination angles, multi-angle (MA) TIRF has been examined to offer a nanoscale axial and a subsecond temporal resolution. However, conventional MA-TIRF still performs badly in lateral resolution and fails to characterize the depth image in densely distributed regions. Here, we emphasize the lateral super-resolution in the MA-TIRF, exampled by simply introducing polarization modulation into the illumination procedure. Equipped with a sparsity and accelerated proximal algorithm, we examine a more precise 3D sample structure compared with previous methods, enabling live cell imaging with a temporal resolution of 2 s and recovering high-resolution mitochondria fission and fusion processes. We also shared the recovery program, which is the first open-source recovery code for MA-TIRF, to the best of our knowledge.
Stability of Contact Lines in Fluids: 2D Stokes Flow
NASA Astrophysics Data System (ADS)
Guo, Yan; Tice, Ian
2018-02-01
In an effort to study the stability of contact lines in fluids, we consider the dynamics of an incompressible viscous Stokes fluid evolving in a two-dimensional open-top vessel under the influence of gravity. This is a free boundary problem: the interface between the fluid in the vessel and the air above (modeled by a trivial fluid) is free to move and experiences capillary forces. The three-phase interface where the fluid, air, and solid vessel wall meet is known as a contact point, and the angle formed between the free interface and the vessel is called the contact angle. We consider a model of this problem that allows for fully dynamic contact points and angles. We develop a scheme of a priori estimates for the model, which then allow us to show that for initial data sufficiently close to equilibrium, the model admits global solutions that decay to equilibrium exponentially quickly.
Archer, R J; Campbell, A I; Ebbens, S J
2015-09-14
The ability to control the degree of spin, or rotational velocity, for catalytic swimming devices opens up the potential to access well defined spiralling trajectories, enhance cargo binding rate, and realise theoretically proposed behaviour such as chiral diffusion. Here we assess the potential to impart a well-defined spin to individual catalytic Janus swimmers by using glancing angle metal evaporation onto a colloidal crystal to break the symmetry of the catalytic patch due to shadowing by neighbouring colloids. Using this approach we demonstrate a well-defined relationship between the glancing angle and the ratio of rotational to translational velocity. This allows batches of colloids with well-defined spin rates in the range 0.25 to 2.5 Hz to be produced. With reference to the shape and thickness variations across the catalytically active shapes, and their propulsion mechanism we discuss the factors that can lead to the observed variations in rotational propulsion.
Effect of varying internal geometry on the static performance of rectangular thrust-reverser ports
NASA Technical Reports Server (NTRS)
Re, Richard J.; Mason, Mary L.
1987-01-01
An investigation has been conducted to evaluate the effects of several geometric parameters on the internal performance of rectangular thrust-reverser ports for nonaxisymmetric nozzles. Internal geometry was varied with a test apparatus which simulated a forward-flight nozzle with a single, fully deployed reverser port. The test apparatus was designed to simulate thrust reversal (conceptually) either in the convergent section of the nozzle or in the constant-area duct just upstream of the nozzle. The main geometric parameters investigated were port angle, port corner radius, port location, and internal flow blocker angle. For all reverser port geometries, the port opening had an aspect ratio (throat width to throat height) of 6.1 and had a constant passage area from the geometric port throat to the exit. Reverser-port internal performance and thrust-vector angles computed from force-balance measurements are presented.
Effect of structured visual environments on apparent eye level.
Stoper, A E; Cohen, M M
1989-11-01
Each of 12 subjects set a binocularly viewed target to apparent eye level; the target was projected on the rear wall of an open box, the floor of which was horizontal or pitched up and down at angles of 7.5 degrees and 15 degrees. Settings of the target were systematically biased by 60% of the pitch angle when the interior of the box was illuminated, but by only 5% when the interior of the box was darkened. Within-subjects variability of the settings was less under illuminated viewing conditions than in the dark, but was independent of box pitch angle. In a second experiment, 11 subjects were tested with an illuminated pitched box, yielding biases of 53% and 49% for binocular and monocular viewing conditions, respectively. The results are discussed in terms of individual and interactive effects of optical, gravitational, and extraretinal eye-position information in determining judgements of eye level.
Duff, Anthony P.; Durand, Dominique; Gabel, Frank; Hendrickson, Wayne A.; Hura, Greg L.; Jacques, David A.; Kirby, Nigel M.; Kwan, Ann H.; Pérez, Javier; Pollack, Lois; Ryan, Timothy M.; Sali, Andrej; Schneidman-Duhovny, Dina; Vachette, Patrice; Westbrook, John
2017-01-01
In 2012, preliminary guidelines were published addressing sample quality, data acquisition and reduction, presentation of scattering data and validation, and modelling for biomolecular small-angle scattering (SAS) experiments. Biomolecular SAS has since continued to grow and authors have increasingly adopted the preliminary guidelines. In parallel, integrative/hybrid determination of biomolecular structures is a rapidly growing field that is expanding the scope of structural biology. For SAS to contribute maximally to this field, it is essential to ensure open access to the information required for evaluation of the quality of SAS samples and data, as well as the validity of SAS-based structural models. To this end, the preliminary guidelines for data presentation in a publication are reviewed and updated, and the deposition of data and associated models in a public archive is recommended. These guidelines and recommendations have been prepared in consultation with the members of the International Union of Crystallography (IUCr) Small-Angle Scattering and Journals Commissions, the Worldwide Protein Data Bank (wwPDB) Small-Angle Scattering Validation Task Force and additional experts in the field. PMID:28876235
Economy, Movement Dynamics, and Muscle Activity of Human Walking at Different Speeds.
Raffalt, P C; Guul, M K; Nielsen, A N; Puthusserypady, S; Alkjær, T
2017-03-08
The complex behaviour of human walking with respect to movement variability, economy and muscle activity is speed dependent. It is well known that a U-shaped relationship between walking speed and economy exists. However, it is an open question if the movement dynamics of joint angles and centre of mass and muscle activation strategy also exhibit a U-shaped relationship with walking speed. We investigated the dynamics of joint angle trajectories and the centre of mass accelerations at five different speeds ranging from 20 to 180% of the predicted preferred speed (based on Froude speed) in twelve healthy males. The muscle activation strategy and walking economy were also assessed. The movement dynamics was investigated using a combination of the largest Lyapunov exponent and correlation dimension. We observed an intermediate stage of the movement dynamics of the knee joint angle and the anterior-posterior and mediolateral centre of mass accelerations which coincided with the most energy-efficient walking speed. Furthermore, the dynamics of the joint angle trajectories and the muscle activation strategy was closely linked to the functional role and biomechanical constraints of the joints.
Distribution functions for resonantly trapped orbits in the Galactic disc
NASA Astrophysics Data System (ADS)
Monari, Giacomo; Famaey, Benoit; Fouvry, Jean-Baptiste; Binney, James
2017-11-01
The present-day response of a Galactic disc stellar population to a non-axisymmetric perturbation of the potential has previously been computed through perturbation theory within the phase-space coordinates of the unperturbed axisymmetric system. Such an Eulerian linearized treatment, however, leads to singularities at resonances, which prevent quantitative comparisons with data. Here, we manage to capture the behaviour of the distribution function (DF) at a resonance in a Lagrangian approach, by averaging the Hamiltonian over fast angle variables and re-expressing the DF in terms of a new set of canonical actions and angles variables valid in the resonant region. We then follow the prescription of Binney, assigning to the resonant DF the time average along the orbits of the axisymmetric DF expressed in the new set of actions and angles. This boils down to phase-mixing the DF in terms of the new angles, such that the DF for trapped orbits depends only on the new set of actions. This opens the way to quantitatively fitting the effects of the bar and spirals to Gaia data in terms of DFs in action space.
Large-Scale Conformational Dynamics Control H5N1 Influenza Polymerase PB2 Binding to Importin α.
Delaforge, Elise; Milles, Sigrid; Bouvignies, Guillaume; Bouvier, Denis; Boivin, Stephane; Salvi, Nicola; Maurin, Damien; Martel, Anne; Round, Adam; Lemke, Edward A; Jensen, Malene Ringkjøbing; Hart, Darren J; Blackledge, Martin
2015-12-09
Influenza A RNA polymerase complex is formed from three components, PA, PB1, and PB2. PB2 is independently imported into the nucleus prior to polymerase reconstitution. All crystallographic structures of the PB2 C-terminus (residues 536-759) reveal two globular domains, 627 and NLS, that form a tightly packed heterodimer. The molecular basis of the affinity of 627-NLS for importins remained unclear from these structures, apparently requiring large-scale conformational changes prior to importin binding. Using a combination of solution-state NMR, small-angle neutron scattering, small-angle X-ray scattering (SAXS), and Förster resonance energy transfer (FRET), we show that 627-NLS populates a temperature-dependent dynamic equilibrium between closed and open states. The closed state is stabilized by a tripartite salt bridge involving the 627-NLS interface and the linker, that becomes flexible in the open state, with 627 and NLS dislocating into a highly dynamic ensemble. Activation enthalpies and entropies associated with the rupture of this interface were derived from simultaneous analysis of temperature-dependent chemical exchange saturation transfer measurements, revealing a strong temperature dependence of both open-state population and exchange rate. Single-molecule FRET and SAXS demonstrate that only the open-form is capable of binding to importin α and that, upon binding, the 627 domain samples a dynamic conformational equilibrium in the vicinity of the C-terminus of importin α. This intrinsic large-scale conformational flexibility therefore enables 627-NLS to bind importin through conformational selection from a temperature-dependent equilibrium comprising both functional forms of the protein.
Van Berkel, Gary J.; Kertesz, Vilmos
2016-11-15
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Berkel, Gary J.; Kertesz, Vilmos
An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized themore » spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.« less
NASA Astrophysics Data System (ADS)
Leprêtre, A.; Deverchere, J.; Klingelhoefer, F.; Graindorge, D.; Schnurle, P.; Yelles, K.; Bracene, R.
2011-12-01
The origin of the Algerian margin remains one of the key questions still unresolved in the Western Mediterranean sea. This is related to the unknown nature and kinematics of this Neogene basin. Whereas the westernmost margin is generally assumed to have been shaped as a STEP-fault (Subduction-Transform Edge Propagator, transcurrent) margin by the westward displacement of the Alboran block, the central Algerian margin is believed to have involved a NW-SE basin opening related to a southward slab rollback. This work sheds insight on this issue, using data acquired in the context of the Algerian-French program SPIRAL (Sismique Profonde et Investigation Régionale en Algérie): a cruise conducted on the 'R/V L'Atalante' in October-November 2009. It has provided 5 new combined onshore-offshore wide-angle seismic profiles and an extensive multi-channel seismic dataset spread along the margin, from Oran to Annaba. In this work, the available structural information on the ~N-S wide-angle transect of Tipaza is presented, where the margin broadens due to the presence of a bathymetric high (the Khayr-Al-Din bank) which is assumed to represent a remaining titled block of the passive margin. Along the transect, 39 OBS and 13 landstations recorded 751 low frequency airgun shots. Travel-time tomography and forward modelling were computed using the software developed by Zelt and Barton (1998) and Zelt and Smith (1992), to obtain the velocity structure in the region. A set of multi-channel seismic reflection profiles including two coincident profiles with the wide-angle data allows a combined interpretation and extend the deep structure in the Bou Ismail Bay. MCS data outline the sedimentary sequence filling the Algerian basin depicting an intensive salt tectonic associated with the Messinan Salinity Crisis and allowing to image locally below the salt layer. The deep penetrating data SPIRAL allow to image the sedimentary sequence in the Algerian basin off Tipaza (West Algiers) and the crustal structure at the continent-ocean boundary. In the Algerian basin off Tipaza, the Moho discontinuity is identified using wide-angle modelling at 11-12 km depth which corresponds in two-way travel-time to 7-8 s. Wide-angle seismic modelling imaged a major thinning of the crust from more of 15 km in the upper margin (KADB) to only 5-6 km in the deep basin. This thinning also marks the rapid transition from a thinned continental crust at the Khayr-al-Din bank to an oceanic crust in the Algerian Basin, revealing a narrow transition zone (20-30 km) between the two domains. This work presents the deep structure of the margin West of Algiers from wide-angle and multichannel seismic data in order to discuss models of opening for the Algerian basin.
Effect of anterior capsule contraction on visual function after cataract surgery.
Hayashi, Ken; Hayashi, Hideyuki
2007-11-01
To examine the effect of contraction of the anterior capsule opening after cataract surgery on visual acuity and contrast sensitivity. Hayashi Eye Hospital, Fukuoka, Japan. Thirty-two eyes of 32 consecutive patients who showed marked contraction of the anterior capsule opening after implantation of an intraocular lens were recruited. The area of the anterior capsule opening was measured by Scheimpflug videophotography before and after neodymium:YAG (Nd:YAG) laser anterior capsulotomy and was correlated with visual acuity and contrast sensitivity. After Nd:YAG laser anterior capsulotomy, the mean area of the anterior capsule opening increased significantly from 8.2 mm(2) to 18.0 mm(2) (P<.0001). Contrast sensitivity at most visual angles also improved significantly after Nd:YAG anterior capsulotomy, although visual acuity did not. The area of the anterior capsule opening before anterior capsulotomy was correlated significantly with contrast sensitivity but not with visual acuity, whereas there was no correlation between the opening area after anterior capsulotomy and visual acuity or contrast sensitivity. Contraction of the anterior capsule opening after cataract surgery significantly diminished contrast sensitivity in proportion to the opening area but did not markedly worsen visual acuity. Neodymium:YAG laser anterior capsulotomy improved contrast sensitivity.
Sopher, Ran S; Amis, Andrew A; Davies, D Ceri; Jeffers, Jonathan Rt
2017-01-01
Data about a muscle's fibre pennation angle and physiological cross-sectional area are used in musculoskeletal modelling to estimate muscle forces, which are used to calculate joint contact forces. For the leg, muscle architecture data are derived from studies that measured pennation angle at the muscle surface, but not deep within it. Musculoskeletal models developed to estimate joint contact loads have usually been based on the mean values of pennation angle and physiological cross-sectional area. Therefore, the first aim of this study was to investigate differences between superficial and deep pennation angles within each muscle acting over the ankle and predict how differences may influence muscle forces calculated in musculoskeletal modelling. The second aim was to investigate how inter-subject variability in physiological cross-sectional area and pennation angle affects calculated ankle contact forces. Eight cadaveric legs were dissected to excise the muscles acting over the ankle. The mean surface and deep pennation angles, fibre length and physiological cross-sectional area were measured. Cluster analysis was applied to group the muscles according to their architectural characteristics. A previously validated OpenSim model was used to estimate ankle muscle forces and contact loads using architecture data from all eight limbs. The mean surface pennation angle for soleus was significantly greater (54%) than the mean deep pennation angle. Cluster analysis revealed three groups of muscles with similar architecture and function: deep plantarflexors and peroneals, superficial plantarflexors and dorsiflexors. Peak ankle contact force was predicted to occur before toe-off, with magnitude greater than five times bodyweight. Inter-specimen variability in contact force was smallest at peak force. These findings will help improve the development of experimental and computational musculoskeletal models by providing data to estimate force based on both surface and deep pennation angles. Inter-subject variability in muscle architecture affected ankle muscle and contact loads only slightly. The link between muscle architecture and function contributes to the understanding of the relationship between muscle structure and function.
2012-05-11
Instructor Rob Mortin watches as Stennis Space Center firefighters Lt. Greg Lampley, Rodney Boone, Vance Forrest and Billy Scarborough practice high-angle rope rescue techniques during a May 11, 2012, training exercise. The exercise specifically focused on scenarios applicable to the 300-foot-tall, open-steel-structure A-3 Test Stand under construction at the rocket engine test facility.
Coming to Terms with MOOCs: A Community College Angle
ERIC Educational Resources Information Center
Fifield, Mary L.
2013-01-01
When MIT approached Bunker Hill Community College (BHCC) to participate in edX, the new Harvard/MIT massive open online course (MOOC) initiative, the administrators reacted with both interest and skepticism. What did MIT have in mind for Bunker Hill Community College? Today at BHCC, the establishment of "Learning Communities" transforms…
Cho, Hyun-Kyung; Kee, Changwon; Yang, Heon; Huh, Hyoun Do; Kim, Su Jin; Park, Young Min; Park, Jong Moon
2017-11-01
To compare the quantitative changes of peripheral angle after laser iridotomy (LI) alone (group A) or combined LI and Iridoplasty (group B) using iridotrabecular contact (ITC) index by swept-source anterior segment optical coherence tomography (AS-OCT). In this prospective comparative observational study, OCT images were obtained before and after the procedure. In each image frame, scleral spur (SS) and the ITC end point (EP) were marked and ITC index was calculated as a percentage of the angle closure from 360°. Age, gender, diagnosis and initial ITC index in Group B were matched with group A. Changes in ITC index, anterior chamber angle parameters, and intraocular pressure (IOP) were inspected. Thirty-three eyes (20 patients) with shallow anterior chamber were included in each group. Initial ITC index and initial IOP were not significantly different between the two groups (both p > 0.05). However, ITC index and IOP after the procedure were significantly lower in group B than those in group A (ITC index: 31.3 ± 23.2 in group A, 19.0 ± 21.3 in group B, p = 0.011, IOP: p = 0.004). All anterior chamber angle parameters in group B and all parameters in group A except nasal trabecular-iris angles (TIA) were significantly increased after the laser procedure (all p < 0.05). In patients with shallow anterior chamber, combined LI and Iridoplasty may open the peripheral angle better than LI alone. Iridoplasty may be able to additionally relieve the peripheral angle closure caused by other mechanisms than pupillary block. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Gros-Otero, Juan; Castejón, Miguel; Paz-Moreno, Javier; Mikropoulos, Dimitrios; Teus, Miguel
2015-01-01
To evaluate the association between clinical parameters and the diagnosis of progression using VFI (Visual Field Index) and AGIS (Advanced Glaucoma Intervention Study) score in primary open angle glaucoma. Retrospective study of 517 visual fields of 78 eyes with primary open angle glaucoma analyzed with VFI and AGIS score. Clinical data registered included: age, sphere, pachimetry, basal intraocular pressure (IOP), and IOP during the follow up. Only the AGIS score diagnosis of progression was associated with the clinical parameters registered. Among the analyzed data, the mean IOP during follow up (p = 0.0005) and IOP at the third month of follow up (p = 0.004) were statistically associated with progression using the AGIS criteria. The diagnosis of perimetric progression using the AGIS score in the current study was closer to the real functional progression than the diagnosis using the VFI, as the former was associated with known risk factors for progression in glaucoma. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Hommer, A
2010-06-01
Glaucoma affects an increasing number of people worldwide and is the second leading cause of blindness. The aim of antiglaucoma therapy is to maintain a patient's visual function and quality of life. Prostaglandin analogues are first-line topical antiglaucoma therapy. They are effective at lowering intraocular pressure (IOP) and are generally well tolerated, with fewer systemic adverse events compared with the other classes. However, the use of prostaglandin analogues can be associated with ocular adverse effects, such as stinging/burning sensation, dry eyes, iris and periocular hyperpigmentation, and eye lash growth, which can affect patient compliance. Preservatives used in antiglaucoma preparations can have dose-dependent toxic effects, which contribute to adverse effects. The development of preservative-free preparations may reduce such adverse effects and therefore improve patient compliance. Tafluprost is a prostaglandin analogue in a preservative-free formulation that was recently approved for the reduction of elevated IOP in open-angle glaucoma and ocular hypertension. Copyright 2010 Prous Science, S.A.U. or its licensors. All rights reserved.
Nanobubbles in confined solution: Generation, contact angle, and stability.
Wei, Jiachen; Zhang, Xianren; Song, Fan; Shao, Yingfeng
2018-02-14
The formation of gas bubbles presents a frequent challenge to microfluidic operations, for which fluids are geometrically confined to a microscale space. Here, to understand the mechanism of nucleating gas bubbles in microfluidic devices, we investigate the formation and stability of nanobubbles in confined solutions. Our molecular dynamics simulations show that while pinning of the contact line is a prerequisite for the stability of surface nanobubbles in open systems that can exchange gas with surrounding environment, in confined solutions, stable nanobubbles can exist even without pinning. In supersaturated condition, stable bubbles can be found in confined solutions with acute or obtuse contact angle, depending on the substrate hydrophobicity. We also demonstrate that when open to the bulk solution, the stable nanobubbles in closed systems would become unstable unless both supersaturation and pinning of the contact line are satisfied. Our results not only shed light on the design of novel heterogeneous surfaces for generating nanobubbles in confined space with controllable shape and stability but also address the crucial effect of gas exchange with the surroundings in determining the stability of nanobubbles.
Nanobubbles in confined solution: Generation, contact angle, and stability
NASA Astrophysics Data System (ADS)
Wei, Jiachen; Zhang, Xianren; Song, Fan; Shao, Yingfeng
2018-02-01
The formation of gas bubbles presents a frequent challenge to microfluidic operations, for which fluids are geometrically confined to a microscale space. Here, to understand the mechanism of nucleating gas bubbles in microfluidic devices, we investigate the formation and stability of nanobubbles in confined solutions. Our molecular dynamics simulations show that while pinning of the contact line is a prerequisite for the stability of surface nanobubbles in open systems that can exchange gas with surrounding environment, in confined solutions, stable nanobubbles can exist even without pinning. In supersaturated condition, stable bubbles can be found in confined solutions with acute or obtuse contact angle, depending on the substrate hydrophobicity. We also demonstrate that when open to the bulk solution, the stable nanobubbles in closed systems would become unstable unless both supersaturation and pinning of the contact line are satisfied. Our results not only shed light on the design of novel heterogeneous surfaces for generating nanobubbles in confined space with controllable shape and stability but also address the crucial effect of gas exchange with the surroundings in determining the stability of nanobubbles.
Numerical modelling of orthogonal cutting: application to woodworking with a bench plane.
Nairn, John A
2016-06-06
A numerical model for orthogonal cutting using the material point method was applied to woodcutting using a bench plane. The cutting process was modelled by accounting for surface energy associated with wood fracture toughness for crack growth parallel to the grain. By using damping to deal with dynamic crack propagation and modelling all contact between wood and the plane, simulations could initiate chip formation and proceed into steady-state chip propagation including chip curling. Once steady-state conditions were achieved, the cutting forces became constant and could be determined as a function of various simulation variables. The modelling details included a cutting tool, the tool's rake and grinding angles, a chip breaker, a base plate and a mouth opening between the base plate and the tool. The wood was modelled as an anisotropic elastic-plastic material. The simulations were verified by comparison to an analytical model and then used to conduct virtual experiments on wood planing. The virtual experiments showed interactions between depth of cut, chip breaker location and mouth opening. Additional simulations investigated the role of tool grinding angle, tool sharpness and friction.
An Experimental Comparison Between Flexible and Rigid Airfoils at Low Reynolds Numbers
NASA Astrophysics Data System (ADS)
Uzodinma, Jaylon; Macphee, David
2017-11-01
This study uses experimental and computational research methods to compare the aerodynamic performance of rigid and flexible airfoils at a low Reynolds number throughout varying angles of attack. This research can be used to improve the design of small wind turbines, micro-aerial vehicles, and any other devices that operate at low Reynolds numbers. Experimental testing was conducted in the University of Alabama's low-speed wind tunnel, and computational testing was conducted using the open-source CFD code OpenFOAM. For experimental testing, polyurethane-based (rigid) airfoils and silicone-based (flexible) airfoils were constructed using acrylic molds for NACA 0012 and NACA 2412 airfoil profiles. Computer models of the previously-specified airfoils were also created for a computational analysis. Both experimental and computational data were analyzed to examine the critical angles of attack, the lift and drag coefficients, and the occurrence of laminar boundary separation for each airfoil. Moreover, the computational simulations were used to examine the resulting flow fields, in order to provide possible explanations for the aerodynamic performances of each airfoil type. EEC 1659710.
Common variants near ABCA1, AFAP1 and GMDS confer risk of primary open-angle glaucoma
Fogarty, Rhys; Sharma, Shiwani; Hewitt, Alex W.; Martin, Sarah; Law, Matthew H.; Cremin, Katie; Bailey, Jessica N. Cooke; Loomis, Stephanie J.; Pasquale, Louis R.; Haines, Jonathan L.; Hauser, Michael A.; Viswanathan, Ananth C.; McGuffin, Peter; Topouzis, Fotis; Foster, Paul J.; Graham, Stuart L; Casson, Robert J; Chehade, Mark; White, Andrew J; Zhou, Tiger; Souzeau, Emmanuelle; Landers, John; Fitzgerald, Jude T; Klebe, Sonja; Ruddle, Jonathan B; Goldberg, Ivan; Healey, Paul R; Mills, Richard A.; Wang, Jie Jin; Montgomery, Grant W.; Martin, Nicholas G.; Radford-Smith, Graham; Whiteman, David C.; Brown, Matthew A.; Wiggs, Janey L.; Mackey, David A; Mitchell, Paul; MacGregor, Stuart; Craig, Jamie E.
2014-01-01
Primary open-angle glaucoma (POAG) is a major cause of irreversible blindness worldwide. We performed a genome-wide association study in an Australian discovery cohort comprising 1,155 advanced POAG cases and 1,992 controls. Association of the top SNPs from the discovery stage was investigated in two Australian replication cohorts (total 932 cases, 6,862 controls) and two US replication cohorts (total 2,616 cases, 2,634 controls). Meta-analysis of all cohorts revealed three novel loci associated with development of POAG. These loci are located upstream of ABCA1 (rs2472493 [G] OR=1.31, P= 2.1 × 10−19), within AFAP1 (rs4619890 [G] OR=1.20, P= 7.0 × 10−10) and within GMDS (rs11969985 [G] OR=1.31, and P= 7.7 × 10−10). Using RT-PCR and immunolabelling, we also showed that these genes are expressed within human retina, optic nerve and trabecular meshwork and that ABCA1 and AFAP1 are also expressed in retinal ganglion cells. PMID:25173105
Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: A rarely reported association
Mitra, Arijit; Ramakrishnan, R.; Kader, Mohideen Abdul
2014-01-01
A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA) of hand movement (HM) in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD) in right eye. Intraocular pressure (IOP) was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA) in right eye and cup disc ratio (CDR) of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS) with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature. PMID:25230966
Open angle glaucoma in a case of Type IV Ehler Danlos syndrome: a rarely reported association.
Mitra, Arijit; Ramakrishnan, R; Kader, Mohideen Abdul
2014-08-01
A 26-year-old male presented to us with defective vision in the left eye. He had best corrected visual acuity (BCVA) of hand movement (HM) in right eye and 6/9 in left eye. He had ptosis with ectropion in both eyes and relative afferent pupillary defect (RAPD) in right eye. Intraocular pressure (IOP) was 46 and 44 mmHg in right and left eye, respectively. Fundus showed glaucomatous optic atrophy (GOA) in right eye and cup disc ratio (CDR) of 0.75 with bipolar rim thinning in left eye. Systemic examination showed hyperextensible skin and joints, acrogeria, hypodontia, high arched palate, and varicose veins. He gave history of easy bruising and tendency to fall and history of intestinal rupture 5 years ago for which he had undergone surgery. He was diagnosed as a case of Type IV Ehler-Danlos syndrome (EDS) with open angle glaucoma. He underwent trabeculectomy in both eyes. This is a rare case that shows glaucoma in a patient of EDS Type IV. Very few such cases have been reported in literature.
Brightness discrimination and contrast sensitivity in chronic glaucoma--a clinical study.
Teoh, S L; Allan, D; Dutton, G N; Foulds, W S
1990-04-01
The visual acuity, the difference in sensitivity of the two eyes to light (brightness ratio), and contrast sensitivity were assessed in 28 patients with chronic open angle glaucoma and compared with those of 41 normal controls of similar ages and visual acuity. The results obtained were related to the results of Tübingen visual field analysis in patients with glaucoma. Twenty-four of the 28 glaucoma patients (86%) had a significant disparity in brightness ratio between the two eyes. This was found to match the frequency of visual field loss. Moreover, there was a significant relationship between the interocular differences in brightness sense and the difference in the degree of visual field loss between the two eyes. Of the glaucoma patients 39% had sum contrast sensitivities outside the normal range for age-matched normal controls. No significant correlation was found between the interocular difference in brightness sense and the visual acuity or the interocular difference in sum contrast sensitivity. It is concluded that, in the presence of a normal visual acuity, the brightness ratio test warrants evaluation as a potential screening test for chronic open angle glaucoma.
Diode laser trabeculoplasty in open angle glaucoma: 50 micron vs. 100 micron spot size.
Veljko, Andreić; Miljković, Aleksandar; Babić, Nikola
2011-01-01
The study was aimed at evaluating the efficacy of diode laser trabeculoplsaty in lowering intraocular pressure in patients with both primary open-angle glaucoma and exfoliation glaucoma by using different size of laser spot. This six-month, unmasked, controlled, prospective study included sixty-two patients with the same number of eyes, who were divided into two groups. Trabeculoplasty was performed with 50 micron and 100 micron laser spot size in the group I and group II, respectively. Other laser parameters were the same for both groups: the wave length of 532 nm, 0.1 second single emission with the power of 600-1200 mW was applied on the 180 degrees of the trabeculum. The mean intraocular pressure decrease in the 50 micron group (group 1) on day 7 was 24% from the baseline and after six-month follow-up period the intraocular pressure decrease was 29.8% (p < 0.001). In the 100 micron group (group II), the mean intraocular pressure decrease on day 7 was 26.5% and after six months it was 39% (p < 0.001).
2016-09-19
Pan may be small as satellites go, but like many of Saturn's ring moons, it has a has a very visible effect on the rings. Pan (17 miles or 28 kilometers across, left of center) holds open the Encke gap and shapes the ever-changing ringlets within the gap (some of which can be seen here). In addition to raising waves in the A and B rings, other moons help shape the F ring, the outer edge of the A ring and open the Keeler gap. This view looks toward the sunlit side of the rings from about 8 degrees above the ring plane. The image was taken in visible light with the Cassini spacecraft narrow-angle camera on July 2, 2016. The view was acquired at a distance of approximately 840,000 miles (1.4 million kilometers) from Saturn and at a sun-Saturn-spacecraft, or phase, angle of 128 degrees. Image scale is 5 miles (8 kilometers) per pixel. Pan has been brightened by a factor of two to enhance its visibility. http://photojournal.jpl.nasa.gov/catalog/PIA20499
[Trabeculotomy ab interno combined with extracapsular cataract extraction and IOL implantation].
Alekseev, B N; Ermolaev, A P
2003-01-01
We made a total of 96 surgeries of extracapsular cataract extraction and IOL implantation combined with trabeculotomy ab interno during a period of 7 years. Patients with both open-angle and narrow-angle glaucoma of stages I and II and with the intraocular pressure (IOP) below or equal to 23 mm Hg according to Goldman under the conditions of hypotensive medicamental regimen were selected for surgery. After IOL was implanted into the lens bag, trabeculotomy ab interno was implemented as stage 2. A special mirror, introduced through the cataract incision, was used for direct gonioscopic monitoring. The trabecula was incised by the edge of a curved surgical knife under direct visual control. We regarded bleeding from the opened sinus as a favorable sign indicative of that the intrascleral collectors were intact. Only minor hyphemas were registered as postoperative complications; there was not a single case of ciliary-and-choroidal detachment. IOP was compensated for, in 6 months after surgery, in 94% of patients--69.8% of them did not use any hypotensive drops.
Contact Modelling of Large Radius Air Bending with Geometrically Exact Contact Algorithm
NASA Astrophysics Data System (ADS)
Vorkov, V.; Konyukhov, A.; Vandepitte, D.; Duflou, J. R.
2016-08-01
Usage of high-strength steels in conventional air bending is restricted due to limited bendability of these metals. Large-radius punches provide a typical approach for decreasing deformations during the bending process. However, as deflection progresses the loading scheme changes gradually. Therefore, modelling of the contact interaction is essential for an accurate description of the loading scheme. In the current contribution, the authors implemented a plane frictional contact element based on the penalty method. The geometrically exact contact algorithm is used for the penetration determination. The implementation is done using the OOFEM - open source finite element solver. In order to verify the simulation results, experiments have been conducted on a bending press brake for 4 mm Weldox 1300 with a punch radius of 30 mm and a die opening of 80 mm. The maximum error for the springback calculation is 0.87° for the bending angle of 144°. The contact interaction is a crucial part of large radius bending simulation and the implementation leads to a reliable solution for the springback angle.
NASA Astrophysics Data System (ADS)
Ismail, Al Emran; Mat Noor, Fazimah; Mohamad, Zaleha; Amran Madlan, Mohd; Zulafif Rahim, M.; Rasidi Ibrahim, M.; Ahmad, Sufizar; Nasrull Abdol Rahman, Mohd; Salleh, Salihatun Md; Sadikin, Azmahani; Mahzan, Shahruddin; Nor, Nik Hisyamudin Muhd
2017-10-01
This paper presents the effect of triggering angles constructed on the top of hybrid woven kenaf/aluminium hollow cylinders on the energy absorption performances. The crushing performances of aluminium tubes can be found widely in open literature. However, lack number of work on the hybridizing the aluminium tubes with woven kenaf fibre is found. Woven kenaf mats are produced and bathed with polymeric resin before they are wrapped around the aluminium tubes twice. Different fibre orientations, ±θ° are used where θ = 0, 15, 30 and 45. Once the hybrid composite hardened, one of their end are chamfered using different angles of 0°, 30°, 45° and 60°. The tubes are quasi-statically compressed in order to obtain their force-displacement responses and crashworthiness parameters are extracted and discussed with the relation of fibre orientations and chamfering angles. It is found that the chamfering angles are only affected the force-displacement curves during the first stage of elastic deformation whereas there is no obvious effect in the second stage. However, varying the fibre orientations are slightly increased the force-displacement curves especially when the fibre is orientated with 30°. Based on the fracture mechanism observations, most of composite experienced large fragmentation indicating that the composites absorbed the crushing energy ineffectively.
Effect of the meniscus contact angle during early regimes of spontaneous imbibition in nanochannels.
Karna, Nabin Kumar; Oyarzua, Elton; Walther, Jens H; Zambrano, Harvey A
2016-11-30
Nanoscale capillarity has been extensively investigated; nevertheless, many fundamental questions remain open. In spontaneous imbibition, the classical Lucas-Washburn equation predicts a singularity as the fluid enters the channel consisting of an anomalous infinite velocity of the capillary meniscus. Bosanquet's equation overcomes this problem by taking into account fluid inertia predicting an initial imbibition regime with constant velocity. Nevertheless, the initial constant velocity as predicted by Bosanquet's equation is much greater than those observed experimentally. In the present study, large scale atomistic simulations are conducted to investigate capillary imbibition of water in slit silica nanochannels with heights between 4 and 18 nm. We find that the meniscus contact angle remains constant during the inertial regime and its value depends on the height of the channel. We also find that the meniscus velocity computed at the channel entrance is related to the particular value of the meniscus contact angle. Moreover, during the subsequent visco-inertial regime, as the influence of viscosity increases, the meniscus contact angle is found to be time dependent for all the channels under study. Furthermore, we propose an expression for the time evolution of the dynamic contact angle in nanochannels which, when incorporated into Bosanquet's equation, satisfactorily explains the initial capillary rise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chan, Chi-Ho; Krolik, Julian H.
2017-07-01
Near-Eddington radiation from active galactic nuclei (AGNs) has significant dynamical influence on the surrounding dusty gas, plausibly furnishing AGNs with geometrically thick obscuration. We investigate this paradigm with radiative magnetohydrodynamics simulations. The simulations solve the magnetohydrodynamics equations simultaneously with the infrared (IR) and ultraviolet (UV) radiative transfer (RT) equations; no approximate closure is used for RT. We find that our torus, when given a suitable sub-Keplerian angular momentum profile, spontaneously evolves toward a state in which its opening angle, density distribution, and flow pattern change only slowly. This “steady” state lasts for as long as there is gas resupply towardmore » the inner edge. The torus is best described as a midplane inflow and a high-latitude outflow. The outflow is launched from the torus inner edge by UV radiation and expands in solid angle as it ascends; IR radiation continues to drive the wide-angle outflow outside the central hole. The dusty outflow obscures the central source in soft X-rays, the IR, and the UV over three-quarters of solid angle, and each decade in column density covers roughly equal solid angle around the central source; these obscuration properties are similar to what observations imply.« less
Marginal adaptation of four inlay casting waxes on stone, titanium, and zirconia dies.
Michalakis, Konstantinos X; Kapsampeli, Vassiliki; Kitsou, Aikaterini; Kirmanidou, Yvone; Fotiou, Anna; Pissiotis, Argirios L; Calvani, Pasquale Lino; Hirayama, Hiroshi; Kudara, Yukio
2014-07-01
Different inlay casting waxes do not produce copings with satisfactory marginal accuracy when used on different die materials. The purpose of this study was to evaluate the marginal accuracy of 4 inlay casting waxes on stone dies and titanium and zirconia abutments and to correlate the findings with the degree of wetting between the die specimens and the inlay casting waxes. The inlay casting waxes tested were Starwax (Dentaurum), Unterziehwachs (Bredent), SU Esthetic wax (Schuler), and Sculpturing wax (Renfert). The marginal opening of the waxes was measured with a stereomicroscope on high-strength stone dies and on titanium and zirconia abutments. Photographic images were obtained, and the mean marginal opening for each specimen was calculated. A total of 1440 measurements were made. Wetting between die materials and waxes was determined after fabricating stone, titanium, and zirconia rectangular specimens. A calibrated pipette was used to place a drop of molten wax onto each specimen. The contact angle was calculated with software after an image of each specimen had been made with a digital camera. Collected data were subjected to a 2-way analysis of variance (α=.05). Any association between marginal accuracy and wetting of different materials was found by using the Pearson correlation. The wax factor had a statistically significant effect both on the marginal discrepancy (F=158.31, P<.001) and contact angle values (F=68.09, P<.001). A statistically significant effect of the die material factor both on the marginal adaptation (F=503.47, P<.001) and contact angle values (F=585.02, P<.001) was detected. A significant correlation between the marginal accuracy and the contact angle values (Pearson=0.881, P=.01) was also found. Stone dies provided wax copings with the best marginal integrity, followed by titanium and zirconia abutments. Unterziehwachs (Bredent), wax produced the best marginal adaptation on different die materials. A significant correlation was found between the marginal accuracy and the contact angle values. As the contact angle value became smaller, the marginal accuracy improved. All combinations of waxes and stone and titanium dies presented a high wettability. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Valbuena, M. A.; Avila, J.; Pantin, V.; Drouard, S.; Guyot, H.; Asensio, M. C.
2006-05-01
Low dimensional (LD) metallic oxides have been a subject of continuous interest in the last two decades, mainly due to the electronic instabilities that they present at low temperatures. In particular, charge density waves (CDW) instabilities associated with a strong electron-phonon interaction have been found in Molybdenum metallic oxides such as KMo 6O 17 purple bronze. We report an angle resolved photoemission (ARPES) study from room temperature (RT) to T ˜40 K well below the Peierls transition temperature for this material, with CDW transition temperature TCDW ˜120 K. We have focused on photoemission spectra along ΓM high symmetry direction as well as photoemission measurements were taken as a function of temperature at one representative kF point in the Brillouin zone in order to look for the characteristic gap opening after the phase transition. We found out a pseudogap opening and a decrease in the density of states near the Fermi energy, EF, consistent with the partial removal of the nested portions of the Fermi surface (FS) at temperature below the CDW transition. In order to elucidate possible Fermi liquid (FL) or non-Fermi liquid (NFL) behaviour we have compared the ARPES data with that one reported on quasi-1D K 0.3MoO 3 blue bronze.
Liu, Peng; Wang, Qiong; Niu, Meixing; Wang, Dunyou
2017-08-10
Combining multi-level quantum mechanics theories and molecular mechanics with an explicit water model, we investigated the ring opening process of guanine damage by hydroxyl radical in aqueous solution. The detailed, atomic-level ring-opening mechanism along the reaction pathway was revealed in aqueous solution at the CCSD(T)/MM levels of theory. The potentials of mean force in aqueous solution were calculated at both the DFT/MM and CCSD(T)/MM levels of the theory. Our study found that the aqueous solution has a significant effect on this reaction in solution. In particular, by comparing the geometries of the stationary points between in gas phase and in aqueous solution, we found that the aqueous solution has a tremendous impact on the torsion angles much more than on the bond lengths and bending angles. Our calculated free-energy barrier height 31.6 kcal/mol at the CCSD(T)/MM level of theory agrees well with the one obtained based on gas-phase reaction profile and free energies of solvation. In addition, the reaction path in gas phase was also mapped using multi-level quantum mechanics theories, which shows a reaction barrier at 19.2 kcal/mol at the CCSD(T) level of theory, agreeing very well with a recent ab initio calculation result at 20.8 kcal/mol.
NASA Astrophysics Data System (ADS)
Olsson, F.; Xie, M.; Lourdudoss, S.; Prieto, I.; Postigo, P. A.
2008-11-01
We present a model for the filtration of dislocations inside the seed window in epitaxial lateral overgrowth (ELO). We found that, when the additive effects of image and gliding forces exceed the defect line tension force, filtering can occur even in the openings. The model is applied to ELO of InP on Si where the opening size and the thermal stress arising due to the mask and the grown material are taken into account and analyzed. Further, we have also designed the mask patterns in net structures, where the tilting angles of the openings in the nets are chosen in order to take advantage of the filtering in the openings more effectively, and to minimize new defects due to coalescence in the ELO. Photoluminescence intensities of ELO InP on Si and on InP are compared and found to be in qualitative agreement with the model.
All-digital signal-processing open-loop fiber-optic gyroscope with enlarged dynamic range.
Wang, Qin; Yang, Chuanchuan; Wang, Xinyue; Wang, Ziyu
2013-12-15
We propose and realize a new open-loop fiber-optic gyroscope (FOG) with an all-digital signal-processing (DSP) system where an all-digital phase-locked loop is employed for digital demodulation to eliminate the variation of the source intensity and suppress the bias drift. A Sagnac phase-shift tracking method is proposed to enlarge the dynamic range, and, with its aid, a new open-loop FOG, which can achieve a large dynamic range and high sensitivity at the same time, is realized. The experimental results show that compared with the conventional open-loop FOG with the same fiber coil and optical devices, the proposed FOG reduces the bias instability from 0.259 to 0.018 deg/h, and the angle random walk from 0.031 to 0.006 deg/h(1/2), moreover, enlarges the dynamic range to ±360 deg/s, exceeding the maximum dynamic range ±63 deg/s of the conventional open-loop FOG.
NASA Astrophysics Data System (ADS)
Ueki, Hironobu; Ishida, Masahiro; Sakaguchi, Daisaku
2005-06-01
In order to investigate the effect of transient needle opening on early stage of spray behavior, simultaneous measurements of velocity and size of droplet were conducted by a newly developed laser 2-focus velocimeter (L2F). The micro-scale probe of the L2F was consisted of two foci with a distance of 36 µm. The tested nozzle had a single hole with a diameter of 0.2 mm. The measurements of injection pressure, needle lift, and crank angle were synchronized with the spray measurement by the L2F at the position 10 mm downstream from the nozzle exit. It has been clearly shown that the velocity and size of droplet increase with needle valve opening and that the probability density distribution of droplet size can be fitted to the Nukiyama-Tanasawa distribution under the transient needle opening condition.
Gil, Robert J; Vassilev, Dobrin; Formuszewicz, Radoslaw; Rusicka-Piekarz, Teresa; Doganov, Alexander
2009-12-01
The two main problems unresolved in coronary bifurcation stenting are periprocedural side branch compromise and higher restenosis at long term. The purpose of this study is to reveal the link between periprocedural side branch compromise and long-term results after main vessel stenting only in coronary bifurcations. Eighty-four patients formed the study population. The inclusion criteria were good-quality angiograms, with maximal between-branch angle opening, no overlap, permitting accurate angiographic analysis. Carina angle (alpha)-the distal angle between main vessel (MV) before bifurcation and side branch (SB)-was measured pre- and poststenting. Clinical follow-up 9-12 months was obtained with coronary angiography if needed. The patient population was high-risk with 33% diabetics and 84% two- and three-vessel disease. Ninety-five stents were implanted in 92 lesions, with three T-stenting cases. Drug-eluting stents were implanted in 54%. Kissing-balloon (KBI) or sequential inflation was performed in 35%. SB functional closure occurred in 17.4%, with independent predictors alpha < 40 degrees and diameter ratio MB/SB >1.22. After 12+/-4 months there were five myocardial infarctions (6%) and 13 (15%) target lesion revascularization procedures. Independent predictors of major cardiovascular events were carina angle <40 degrees , MB lesion length >8 mm, negative change of between-branch angle, DES usage, and KBI. Smaller carina angle with straightening of MV-main branch from stent implantation in coronary bifurcations predicted higher SB compromise, restenosis, and MACE rates during follow-up of 1 year.
Deie, Masataka; Hoso, Takayuki; Shimada, Noboru; Iwaki, Daisuke; Nakamae, Atsuo; Adachi, Nobuo; Ochi, Mitsuo
2014-12-01
High tibial osteotomy (HTO) for medial knee osteoarthritis (OA) is mainly performed via two procedures: closing wedge HTO (CW) and opening wedge HTO (OW). In this study, differences between these procedures were assessed by serial clinical evaluation and gait analysis before and after surgery. Twenty-one patients underwent HTO for medial knee OA in 2011 and 2012, with 12 patients undergoing CW and nine undergoing OW. The severity of OA was classified according to the Kellgren-Lawrence classification. The Japanese Orthopedic Association score for assessment of knee OA (JOA score), the Numeric Rating Scale (NRS), and the femoral tibial angle (FTA) on X-ray were evaluated. For gait analysis, gait speed, varus moment, varus angle and lateral thrust were calculated. The JOA score and NRS were improved significantly one year postoperatively in both groups. The FTA was maintained in both groups at one year. Varus angle and varus moment were significantly improved in both groups at each postoperative follow-up, when compared preoperatively. Lateral thrust was significantly improved at three months postoperatively in both groups. However, the significant improvement in lateral thrust had disappeared in the CW group six months postoperatively, whereas it was maintained for at least one year in the OW group. This study found that clinical outcomes were well maintained after HTO. OW reduced knee varus moment and lateral thrust, whereas CW had little effect on reducing lateral thrust. Level IV. Copyright © 2014 Elsevier B.V. All rights reserved.
Smale, Kenneth B; Potvin, Brigitte M; Shourijeh, Mohammad S; Benoit, Daniel L
2017-09-06
The recent development of a soft tissue artifact (STA) suppression method allows us to re-evaluate the tibiofemoral kinematics currently linked to non-contact knee injuries. The purpose of this study was therefore to evaluate knee joint kinematics and kinetics in six degrees of freedom (DoF) during the loading phases of a jump lunge and side cut using this in silico method. Thirty-five healthy adults completed these movements and their surface marker trajectories were then scaled and processed with OpenSim's inverse kinematics (IK) and inverse dynamics tools. Knee flexion angle-dependent kinematic constraints defined based on previous bone pin (BP) marker trajectories were then applied to the OpenSim model during IK and these constrained results were then processed with the standard inverse dynamics tool. Significant differences for all hip, knee, and ankle DoF were observed after STA suppression for both the jump lunge and side cut. Using clinically relevant effect size estimates, we conclude that STA contamination had led to misclassifications in hip transverse plane angles, knee frontal and transverse plane angles, medial/lateral and distractive/compressive knee translations, and knee frontal plane moments between the NoBP and the BP IK solutions. Our results have substantial clinical implications since past research has used joint kinematics and kinetics contaminated by STA to identify risk factors for musculoskeletal injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.
Factors Affecting the Capture Efficiency of a Fume Extraction Torch for Gas Metal Arc Welding.
Bonthoux, Francis
2016-07-01
Welding fumes are classified as Group 2B 'possibly carcinogenic' and this prompts to the implementation of local exhaust ventilation (LEV). The fume extraction torch with LEV integrated into the tool is the most attractive solution but its capture efficiency is often disappointing in practice. This study assesses the main parameters affecting fume capture efficiency namely the extraction flow rate, the positioning of the suction openings on the torch, the angle of inclination of the torch to the workpiece during welding, the metal transfer modes, and the welding deposition rate. The theoretical velocity induced by suction, estimated from the extraction flow rate and the position of the suction openings, is the main parameter affecting effectiveness of the device. This is the design parameter and its value should never be <0.25 m s(-1) The angle of the torch relative to the workpiece also has a great deal of influence. To improve efficiency, work station layouts need to favour positions where the torch is held with angles closer to perpendicular (<15°). Welding with high deposition rates (>1.1g s(-1)) and spray transfer leads to low capture efficiency if induced velocities are <0.5 m s(-1) The results of the study can be used in the design of integrated on-torch extraction systems and provide information for fixing system objectives. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
NASA Astrophysics Data System (ADS)
Karaev, V. Yu.; Panfilova, M. A.; Titchenko, Yu. A.; Meshkov, E. M.; Balandina, G. N.; Andreeva, Z. V.
2017-12-01
The launch of the Dual-frequency Precipitation Radar (DPR) opens up new opportunities for studying and monitoring the land and inland waters. It is the first time radar with a swath (±65°) covering regions with cold climate where waters are covered with ice and land with snow for prolonged periods of time has been used. It is also the first time that the remote sensing is carried out at small incidence angles (less than 19°) at two frequencies (13.6 and 35.5 GHz). The high spatial resolution (4-5 km) significantly increases the number of objects that can be studied using the new radar. Ilmen Lake is chosen as the first test object for the development of complex programs for processing and analyzing data obtained by the DPR. The problem of diagnostics of ice-cover formation and destruction according to DPR data has been considered. It is shown that the dependence of the radar backscatter cross section on the incidence angle for autumn ice is different from that of spring ice, and can be used for classification. A comparison with scattering on the water surface has shown that, at incidence angles exceeding 10°, it is possible to discern all three types of reflecting surfaces: open water, autumn ice, and spring ice, under the condition of making repeated measurements to avoid possible ambiguity caused by wind.
Lavallé, F; Pascal-Mousselard, H; Rouvillain, J L; Ribeyre, D; Delattre, O; Catonné, Y
2004-10-01
The aim of this radiological study was to evaluate the use of a biphasic ceramic wedge combined with plate fixation with locked adjustable screws for open wedge tibial osteotomy. Twenty-six consecutive patients (27 knees) underwent surgery between December 1999 and March 2002 to establish a normal lower-limb axis. The series included 6 women and 20 men, mean age 50 years (16 right knees and 11 left knees). Partial weight-bearing with crutches was allowed on day 1. A standard radiological assessment was performed on day 1, 90, and 360 (plain AP and lateral stance films of the knee). A pangonogram was performed before surgery and at day 360. Presence of a lateral metaphyseal space, development of peripheral cortical bridges, and osteointegration of the bone substitute-bone interface were evaluated used to assess bone healing. The medial tibial angle between the line tangent to the tibial plateau and the anatomic axis of the tibia (beta) was evaluated to assess preservation of postoperative correction. The HKA angle was determined. Three patients were lost to follow-up and 23 patients (24 knees) were retained for analysis. At last follow-up, presence of peripheral cortical bridges and complete filling of the lateral metaphyseal space demonstrated bone healing in all patients. Good quality osteointegration was achieved since 21 knees did not present an interface between the bone substitute and native bone (homogeneous transition zone). The beta angle was unchanged for 23 knees. A normal axis was observed in patients (16 knees) postoperatively. Use of a biphasic ceramic wedge in combination with plate fixation with locked adjustable screws is a reliable option for open wedge tibial osteotomy. The bone substitute fills the gap well. Tolerance and integration are optimal. Bone healing is achieved. Plate fixation with protected weight bearing appears to be a solid assembly, maintaining these corrections.
Pleet, Alexander; Sulewski, Melanie; Salowe, Rebecca J.; Fertig, Raymond; Salinas, Julia; Rhodes, Allison; Merritt, William; Natesh, Vikas; Huang, Jiayan; Gudiseva, Harini V.; Collins, David W.; Chavali, Venkata Ramana Murthy; Tapino, Paul; Lehman, Amanda; Regina-Gigiliotti, Meredith; Miller-Ellis, Eydie; Sankar, Prithvi; Ying, Gui-Shuang; O’Brien, Joan M.
2016-01-01
Purpose To determine the risk factors associated with progression to blindness from primary open-angle glaucoma (POAG) in an African-American population. Methods This study examined 2119 patients enrolled in the Primary Open-Angle African-American Glaucoma Genetics (POAAGG) study. A total of 59 eyes were identified as legally blind as a result of POAG (cases) and were age-and sex-matched to 59 non-blind eyes with glaucoma (controls). Chart reviews were performed to record known and suspected risk factors. Results Cases were diagnosed with POAG at an earlier age than controls (p = 0.005). Of the 59 eyes of cases, 16 eyes (27.1%) presented with blindness at diagnosis. Cases had worse visual acuity (VA) at diagnosis (p < 0.0001), with VA worse than 20/40 conferring a 27 times higher risk of progression to blindness (p = 0.0005). Blind eyes also demonstrated more visual field defects (p = 0.01), higher pretreatment intraocular pressure (IOP; p < 0.0001), and higher cup-to-disc ratio (p = 0.006) at diagnosis. IOP was less controlled in cases, and those with IOP ≥21 mmHg at more than 20% of follow-up visits were 73 times more likely to become blind (p < 0.0001). Cases missed a greater number of appointments per year (p = 0.003) and had non-adherence issues noted in their charts more often than controls (p = 0.03). However, other compliance data did not significantly differ between groups. Conclusion Access to care, initial VA worse than 20/40, and poor control of IOP were the major risk factors associated with blindness from POAG. Future studies should examine earlier, more effective approaches to glaucoma screening as well as the role of genetics in these significantly younger patients who progress to blindness. PMID:27348239
Deshpande, Sarita S; Sonty, Sriram; Ahmad, Afzal
2017-01-01
The purpose of this study is to evaluate the intraocular pressure (IOP)-lowering efficacy of bimatoprost 0.01% solution in patients with primary open-angle glaucoma (POAG), who were switched from bimatoprost 0.03% solution, compared to patients with POAG who continued on bimatoprost 0.03% solution. A retrospective review evaluated 35 patients (35 right eyes [OD], 34 left eyes [OS]) who remained on bimatoprost 0.03% and 30 patients (27 OD, 30 OS) who were switched to bimatoprost 0.01% during the period January 8, 2010 to December 26, 2012. Mean IOP was measured 6 and 3 months before the switch, at switch, and 3, 6, and 12 months after the switch. Hyperemia scores were recorded before and after the switch and were compared to a picture scale. Mean IOP in the group that switched was 16.96±5.03 mmHg in OD and 17.67±5.33 mmHg in OS at baseline. Mean IOP postswitch to bimatoprost 0.01% solution was 17.60±4.34 mmHg in OD and 17.00±3.37 mmHg in OS. IOP was not significantly reduced in either OD or OS postswitch to bimatoprost 0.01% ( P 1 =0.5 OD, P 2 =0.2 OS). The hyperemia scores improved remarkably when bimatoprost 0.03% solution was switched to bimatoprost 0.01% solution ( P <0.001). To our knowledge, this is the first switch study evaluating the hypotensive efficacy and tolerability of bimatoprost in a group of patients with open-angle glaucoma. In this study comparing bimatoprost 0.03% and 0.01% solution, we found improved tolerability postswitch to 0.01% from 0.03% bimatoprost, similar efficacy between the two concentrations before and after switch in the same patient population, and similar IOPs comparable to nonswitch bimatoprost 0.03% solution.
Song, Yuxiang; Chen, Feng; Xiong, Jiang; Guo, Wei; Pan, Xiujie; Jia, Senhao; Liu, Jie
2013-07-01
By observation of the diameter, progression rate, wall thickness, and the opening angle of the abnormal aortic of abdominal aortic aneurysm (AAA) in rats, to observe the effect of saturated hydrogen saline on residual strain of AAA rats, and to investigate its inhibition effect on AAA formation. Twenty healthy male Sprague Dawley rats (weighing, 200-220 g) were randomly divided into 2 groups, which was made the AAA model by infiltration of the abdominal arota with 0.5 mol/L calcium chloride. Saturated hydrogen saline (5 mL/kg) or saline (5 mL/kg) was injected intraperitoneally in the experimental group or control group respectively, every day for 28 days. At 28 days, the diameter, progression rate, wall thickness, and opening angle of the abnormal aorta were mearsured. The aortic tissue was harvested for histological examination (HE staining and aldehyde-fuchsin staining). At 28 days after operation, the diameter of abnormal aorta in 2 groups were significantly higher than preoperative ones (P < 0.05), the progression rate in experimental group (65% +/- 15%) was significantly lower than that in control group (128% +/- 54%) (t=3.611, P=0.005). The opening angle and the wall thickness in experimental group were (88.78 +/- 29.20) degrees and (0.14 +/- 0.03) mm respectively, had significant differences when compared with the values in control group [(44.23 +/- 28.52) degrees and (0.36 +/- 0.05) mm respectively] (P < 0.01). The integrity and continuity of the aortic wall in experimental group were superior to that in the control group. Compared with the control group, the injury of elastic fiber in aortic wall and the infiltration of inflammation were all reduced. Saturated hydrogen saline can maintain good mechanical properties and reduce dilatation of the aorta by increasing residual strain and reducing the remodeling of it.
Evaluation of Aircraft Platforms for SOFIA by Computational Fluid Dynamics
NASA Technical Reports Server (NTRS)
Klotz, S. P.; Srinivasan, G. R.; VanDalsem, William (Technical Monitor)
1995-01-01
The selection of an airborne platform for the Stratospheric Observatory for Infrared Astronomy (SOFIA) is based not only on economic cost, but technical criteria, as well. Technical issues include aircraft fatigue, resonant characteristics of the cavity-port shear layer, aircraft stability, the drag penalty of the open telescope bay, and telescope performance. Recently, two versions of the Boeing 747 aircraft, viz., the -SP and -200 configurations, were evaluated by computational fluid dynamics (CFD) for their suitability as SOFIA platforms. In each configuration the telescope was mounted behind the wings in an open bay with nearly circular aperture. The geometry of the cavity, cavity aperture, and telescope was identical in both platforms. The aperture was located on the port side of the aircraft and the elevation angle of the telescope, measured with respect to the vertical axis, was 500. The unsteady, viscous, three-dimensional, aerodynamic and acoustic flow fields in the vicinity of SOFIA were simulated by an implicit, finite-difference Navier-Stokes flow solver (OVERFLOW) on a Chimera, overset grid system. The computational domain was discretized by structured grids. Computations were performed at wind-tunnel and flight Reynolds numbers corresponding to one free-stream flow condition (M = 0.85, angle of attack alpha = 2.50, and sideslip angle beta = 0 degrees). The computational domains consisted of twenty-nine(29) overset grids in the wind-tunnel simulations and forty-five(45) grids in the simulations run at cruise flight conditions. The maximum number of grid points in the simulations was approximately 4 x 10(exp 6). Issues considered in the evaluation study included analysis of the unsteady flow field in the cavity, the influence of the cavity on the flow across empennage surfaces, the drag penalty caused by the open telescope bay, and the noise radiating from cavity surfaces and the cavity-port shear layer. Wind-tunnel data were also available to compare to the CFD results; the data permitted an assessment of CFD as a design tool for the SOFIA program.
Transition paths of Met-enkephalin from Markov state modeling of a molecular dynamics trajectory.
Banerjee, Rahul; Cukier, Robert I
2014-03-20
Conformational states and their interconversion pathways of the zwitterionic form of the pentapeptide Met-enkephalin (MetEnk) are identified. An explicit solvent molecular dynamics (MD) trajectory is used to construct a Markov state model (MSM) based on dihedral space clustering of the trajectory, and transition path theory (TPT) is applied to identify pathways between open and closed conformers. In the MD trajectory, only four of the eight backbone dihedrals exhibit bistable behavior. Defining a conformer as the string XXXX with X = "+" or "-" denoting, respectively, positive or negative values of a given dihedral angle and obtaining the populations of these conformers shows that only four conformers are highly populated, implying a strong correlation among these dihedrals. Clustering in dihedral space to construct the MSM finds the same four bistable dihedral angles. These state populations are very similar to those found directly from the MD trajectory. TPT is used to obtain pathways, parametrized by committor values, in dihedral state space that are followed in transitioning from closed to open states. Pathway costs are estimated by introducing a kinetics-based procedure that orders pathways from least (shortest) to greater cost paths. The least costly pathways in dihedral space are found to only involve the same XXXX set of dihedral angles, and the conformers accessed in the closed to open transition pathways are identified. For these major pathways, a correlation between reaction path progress (committors) and the end-to-end distance is identified. A dihedral space principal component analysis of the MD trajectory shows that the first three modes capture most of the overall fluctuation, and pick out the same four dihedrals having essentially all the weight in those modes. A MSM based on root-mean-square backbone clustering was also carried out, with good agreement found with dihedral clustering for the static information, but with results that differ significantly for the pathway analysis.
Ellis, J D; Evans, J M; Ruta, D A; Baines, P S; Leese, G; MacDonald, T M; Morris, A D
2000-11-01
To evaluate whether diabetes mellitus is a risk factor for the development of primary open angle glaucoma or ocular hypertension (OHT). A historical cohort study of an unselected population comprising all residents of the Tayside region of Scotland was performed using record linkage techniques followed by case note review. Ascertainment of prevalent diabetes was achieved using the Diabetes Audit and Research in Tayside Study (DARTS) validated regional diabetes register. Glaucoma and treated OHT were defined by encashment of community prescriptions and the statutory surgical procedure coding database. The study population comprised 6631 diabetic subjects and 166 144 non-diabetic subjects aged >40 years without glaucoma or OHT at study entry. 65 patients with diabetes and 958 without diabetes were identified as new cases of glaucoma or treated OHT during the 24 month study period, yielding a standardised morbidity ratio of 127 (95% CI, 96-158). Case note review demonstrated non-differential misclassification of prevalent glaucoma and OHT as incident disease (diabetic cohort 20%, non-diabetic cohort 24%; p=0.56) primarily as a result of non-compliance in medically treated disease. Removing misclassified cases and adjusting for age yielded an incidence of primary open angle glaucoma in diabetes of 1.1/1000 patient years (95% CI, 0.89-1. 31) compared to 0.7/1000 patient years (95% CI, 0.54-0.86) in the non-diabetic cohort; RR 1.57 (95% CI, 0.99-2.48). This study failed to confirm an association between diabetes mellitus and primary open angle glaucoma and ocular hypertension. A non-significant increase in diagnosed and treated disease in the diabetic population was observed, but evidence was also found that detection bias contributes to this association.
Fain, Joel M; Kotak, Sameer; Mardekian, Jack; Bacharach, Jason; Edward, Deepak P; Rauchman, Steven; Brevetti, Teresa; Fox, Janet L; Lovelace, Cherie
2011-06-13
Because latanoprost and the original formulation of travoprost that included benzalkonium chloride (BAK) have been shown to be similar with regard to tolerability, we compared initial topical intraocular pressure (IOP)-lowering medication change rates in patients newly treated with latanoprost or travoprost-Z monotherapy. At 14 clinical practice sites, medical records were abstracted for patients with a diagnosis of open-angle glaucoma or ocular hypertension and who were ≥40 years of age, had a baseline and at least one follow-up visit, and had no prior history of ocular prostaglandin use. Data regarding demographics, ocular/systemic medical histories, clinical variables, therapy initiations and reasons for changes, adverse events, and resource utilization were recorded from randomly chosen eligible charts. Primary outcomes were rates of and reasons for changing from the initial therapy within six months and across the full study period (1000 days). Data from 900 medical charts (latanoprost, 632; travoprost-Z, 268) were included. For both cohorts, average follow-up was >1 year. Cohorts were similar with regard to age (median ~67 years), gender distribution (>50% female), and diagnosis (~80% with open-angle glaucoma). Within six months, rates of index therapy change for latanoprost versus travoprost-Z were 21.2% (134/632) and 28.7% (77/268), respectively (p = 0.0148); across the full study period, rates were 34.5% (218/632) and 45.2% (121/268), respectively (p = 0.0026). Among those who changed their index therapy, insufficient IOP control was the most commonly reported reason followed by adverse events; hyperemia was the most commonly reported adverse event at index therapy change. In this "real world" study of changes in therapy in patients prescribed initial monotherapy with latanoprost with BAK or travoprost-Z with SofZia, medication changes were common in both treatment groups but statistically significantly more frequent with travoprost-Z.