Design criteria monograph for valve components
NASA Technical Reports Server (NTRS)
1974-01-01
Monograph treats valve design technology problems as they were solved in successful development of flightweight operational valves for liquid rocket systems. General practices for cleaning and contamination prevention are summarized. Balance of information is arranged by topic, since detail design requirements apply to most types of valves.
Watts Bar Lock Valve Model Study
2013-08-01
stream of the valve, and cavitation potential for various valve openings. Design modifications to improve performance were to be recommended. The...operation schedule to avoid gate openings with cavitation problems. This report provides results of the recent model experiments performed on the...the mid range openings. The noise is caused by cavitation in the culvert downstream of the filling valves. The vapor cavities that form from the low
Pulmonary valve autotransplantation (the Ross operation).
Ross, D
1988-09-01
In 1967, homografts had been in place five years and the early nonviable and natant freeze-dried valves were showing irrefutable signs of degeneration and calcification. For this reason, in 1967, we moved to reserving both viability and tissue integrity by cryopreservation. To overcome the problems of procurement, the next logical step was to transfer the patient's own pulmonic valve to the aortic area. In the past twenty years, 249 operations have been performed. Of the 249 patients, there have been 16 operative deaths (6.5%), but no operative deaths in the past ten years. There have been no details related to primary tissue failure in the aortic area. There have been 36 reoperations (14.4%).
Cavitation guide for control valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tullis, J.P.
1993-04-01
This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines sixmore » cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.« less
Heat Transfer Search Algorithm for Non-convex Economic Dispatch Problems
NASA Astrophysics Data System (ADS)
Hazra, Abhik; Das, Saborni; Basu, Mousumi
2018-06-01
This paper presents Heat Transfer Search (HTS) algorithm for the non-linear economic dispatch problem. HTS algorithm is based on the law of thermodynamics and heat transfer. The proficiency of the suggested technique has been disclosed on three dissimilar complicated economic dispatch problems with valve point effect; prohibited operating zone; and multiple fuels with valve point effect. Test results acquired from the suggested technique for the economic dispatch problem have been fitted to that acquired from other stated evolutionary techniques. It has been observed that the suggested HTS carry out superior solutions.
Heat Transfer Search Algorithm for Non-convex Economic Dispatch Problems
NASA Astrophysics Data System (ADS)
Hazra, Abhik; Das, Saborni; Basu, Mousumi
2018-03-01
This paper presents Heat Transfer Search (HTS) algorithm for the non-linear economic dispatch problem. HTS algorithm is based on the law of thermodynamics and heat transfer. The proficiency of the suggested technique has been disclosed on three dissimilar complicated economic dispatch problems with valve point effect; prohibited operating zone; and multiple fuels with valve point effect. Test results acquired from the suggested technique for the economic dispatch problem have been fitted to that acquired from other stated evolutionary techniques. It has been observed that the suggested HTS carry out superior solutions.
Carbon Fiber Reinforced Carbon Composites Rotary Valves for Internal Combustion Engines
NASA Technical Reports Server (NTRS)
Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)
1999-01-01
Carbon fiber reinforced carbon composite rotary, sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or warp-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties, do not present the sealing and lubrication problems that have prevented rotary, sleeve, and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.
Oxygen Generation System Laptop Bus Controller Flight Software
NASA Technical Reports Server (NTRS)
Rowe, Chad; Panter, Donna
2009-01-01
The Oxygen Generation System Laptop Bus Controller Flight Software was developed to allow the International Space Station (ISS) program to activate specific components of the Oxygen Generation System (OGS) to perform a checkout of key hardware operation in a microgravity environment, as well as to perform preventative maintenance operations of system valves during a long period of what would otherwise be hardware dormancy. The software provides direct connectivity to the OGS Firmware Controller with pre-programmed tasks operated by on-orbit astronauts to exercise OGS valves and motors. The software is used to manipulate the pump, separator, and valves to alleviate the concerns of hardware problems due to long-term inactivity and to allow for operational verification of microgravity-sensitive components early enough so that, if problems are found, they can be addressed before the hardware is required for operation on-orbit. The decision was made to use existing on-orbit IBM ThinkPad A31p laptops and MIL-STD-1553B interface cards as the hardware configuration. The software at the time of this reporting was developed and tested for use under the Windows 2000 Professional operating system to ensure compatibility with the existing on-orbit computer systems.
Carbon Fiber Reinforced Carbon Composite Rotary Valve for an Internal Combustion Engine
NASA Technical Reports Server (NTRS)
Northam, G.Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)
2000-01-01
Carbon fiber reinforced carbon composite rotary sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or wrap-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties do not present the sealing and lubrication problems that have prevented rotary sleeve and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.
Symbiotic organisms search algorithm for dynamic economic dispatch with valve-point effects
NASA Astrophysics Data System (ADS)
Sonmez, Yusuf; Kahraman, H. Tolga; Dosoglu, M. Kenan; Guvenc, Ugur; Duman, Serhat
2017-05-01
In this study, symbiotic organisms search (SOS) algorithm is proposed to solve the dynamic economic dispatch with valve-point effects problem, which is one of the most important problems of the modern power system. Some practical constraints like valve-point effects, ramp rate limits and prohibited operating zones have been considered as solutions. Proposed algorithm was tested on five different test cases in 5 units, 10 units and 13 units systems. The obtained results have been compared with other well-known metaheuristic methods reported before. Results show that proposed algorithm has a good convergence and produces better results than other methods.
... valve . Learn about the different types of stenosis: Aortic stenosis Tricuspid stenosis Pulmonary stenosis Mitral stenosis Outlook for ... Disease "Innocent" Heart Murmur Problem: Valve Stenosis - Problem: Aortic Valve Stenosis - Problem: Mitral Valve Stenosis - Problem: Tricuspid Valve Stenosis - ...
Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie
2017-12-15
Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.
NASA Technical Reports Server (NTRS)
1973-01-01
The development of and operational programs for effective use in design are presented for liquid rocket pressure regulators, relief valves, check valves, burst disks, and explosive valves. A review of the total design problem is presented, and design elements are identified which are involved in successful design. Current technology pertaining to these elements is also described. Design criteria are presented which state what rule or standard must be imposed on each essential design element to assure successful design. These criteria serve as a checklist of rules for a project manager to use in guiding a design or in assessing its adequacy. Recommended practices are included which state how to satisfy each of the criteria.
Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie
2017-01-01
Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722
The two-stroke poppet valve engine. Part 1: Intake and exhaust ports flow experimental assessments
NASA Astrophysics Data System (ADS)
Kamili Zahidi, M.; Razali Hanipah, M.; Ramasamy, D.; Noor, M. M.; Kadirgama, K.; Rahman, M. M.
2017-10-01
A two-stroke poppet valve engine is developed to overcome the common problems in conventional two-stroke engine designs. However, replacing piston control port with poppet valve will resulted different flow behaviour. This paper is looking at experimental assessment on a two-stroke poppet valve engine configuration to investigate the port flow performance. The aims are to evaluate the intake and exhaust coefficient of discharge and assess the twostroke capability of the cylinder head. The results has shown comparable coefficient of discharge values as production engine for the intake while the exhaust has higher values which is favourable for the two-stroke cycle operation.
1979-11-01
shaft seals during the CASREP data period. Five of these CASREPs reported excessive leakage , two reported ruptured inflatable seals , and one reported...failures, like the DDG-37 Class CASREPs, were related to lube oil problems, steam valve problems, or leaking packing ( steam or oil seals ) that had become...sources of this water: (1) gradual deterioration of the turbine labyrinth seals , (2) leaking of exhaust and relief valves, and (3) condensation in the
A PDMS membrane microvalve with one-dimensional line valve seat for robust microfluidics
NASA Astrophysics Data System (ADS)
Park, Chin-Sung; Hwang, Kyu-Youn; Jung, Wonjong; Namkoong, Kak; Chung, Wonseok; Kim, Joon-Ho; Huh, Nam
2014-02-01
We have developed a monolithic polydimethylsiloxane (PDMS) membrane microvalve with an isotropically etched valve seat for robust microfluidics. In order to avoid bonding or sticking of the PDMS membrane to the valve seat during the bonding process, the valve seat was wet-etched to be a one-dimensional line instead of a plane. The simple wet-etching technique allowed for the fabrication of an anti-bonding architecture in a scalable manner, and it intrinsically prevented contact between the PDMS membrane and valve seat when no external force was applied (i.e., normally open). This approach enables the permanent device assembly so that the microfluidic chip can be operable in a wide range of fluid pressures (e.g., over 200 kPa) without any leakage and sticking problems.
2012-01-01
Background Functional tricuspid regurgitation (TR) occurs in patients with rheumatic mitral valve disease even after mitral valve surgery. The aim of this study was to analyze surgical results of TR after previous successful mitral valve surgery. Methods From September 1996 to September 2008, 45 patients with TR after previous mitral valve replacement underwent second operation for TR. In those, 43 patients (95.6%) had right heart failure symptoms (edema of lower extremities, ascites, hepatic congestion, etc.) and 40 patients (88.9%) had atrial fibrillation. Twenty-six patients (57.8%) were in New York Heart Association (NYHA) functional class III, and 19 (42.2%) in class IV. Previous operations included: 41 for mechanical mitral valve replacement (91.1%), 4 for bioprosthetic mitral valve replacement (8.9%), and 7 for tricuspid annuloplasty (15.6%). Results The tricuspid valves were repaired with Kay's (7 cases, 15.6%) or De Vega technique (4 cases, 8.9%). Tricuspid valve replacement was performed in 34 cases (75.6%). One patient (2.2%) died. Postoperative low cardiac output (LCO) occurred in 5 patients and treated successfully. Postoperative echocardiography showed obvious reduction of right atrium and ventricle. The anterioposterior diameter of the right ventricle decreased to 25.5 ± 7.1 mm from 33.7 ± 6.2 mm preoperatively (P < 0. 05). Conclusion TR after mitral valve replacement in rheumatic heart disease is a serious clinical problem. If it occurs or progresses late after mitral valve surgery, tricuspid valve annuloplasty or replacement may be performed with satisfactory results. Due to the serious consequence of untreated TR, aggressive treatment of existing TR during mitral valve surgery is recommended. PMID:22490269
The Leipzig experience with robotic valve surgery.
Autschbach, R; Onnasch, J F; Falk, V; Walther, T; Krüger, M; Schilling, L O; Mohr, F W
2000-01-01
The study describes the single-center experience using robot-assisted videoscopic mitral valve surgery and the early results with a remote telemanipulator-assisted approach for mitral valve repair. Out of a series of 230 patients who underwent minimally invasive mitral valve surgery, in 167 patients surgery was performed with the use of robotic assistance. A voice-controlled robotic arm was used for videoscopic guidance in 152 cases. Most recently, a computer-enhanced telemanipulator was used in 15 patients to perform the operation remotely. The mitral valve was repaired in 117 and replaced in all other patients. The voice-controlled robotic arm (AESOP 3000) facilitated videoscopic-assisted mitral valve surgery. The procedure was completed without the need for an additional assistant as "solo surgery." Additional procedures like radiofrequency ablation and tricuspid valve repair were performed in 21 and 4 patients, respectively. Duration of bypass and clamp time was comparable to conventional procedures (107 A 34 and 50 A 16 min, respectively). Hospital mortality was 1.2%. Using the da Vinci telemanipulation system, remote mitral valve repair was successfully performed in 13 of 15 patients. Robotic-assisted less invasive mitral valve surgery has evolved to a reliable technique with reproducible results for primary operations and for reoperations. Robotic assistance has enabled a solo surgery approach. The combination with radiofrequency ablation (Mini Maze) in patients with chronic atrial fibrillation has proven to be beneficial. The use of telemanipulation systems for remote mitral valve surgery is promising, but a number of problems have to be solved before the introduction of a closed chest mitral valve procedure.
NASA Technical Reports Server (NTRS)
Hesser, R. J.; Gershman, R.
1975-01-01
A valve opening-response problem encountered during development of a control valve for the Skylab thruster attitude control system (TACS) is described. The problem involved effects of dynamic interaction among valves in the quad-redundant valve package. Also described is a detailed computer simulation of the quad-valve package which was helpful in resolving the problem.
Electrohydraulic linear actuator with two stepping motors controlled by overshoot-free algorithm
NASA Astrophysics Data System (ADS)
Milecki, Andrzej; Ortmann, Jarosław
2017-11-01
The paper describes electrohydraulic spool valves with stepping motors used as electromechanical transducers. A new concept of a proportional valve in which two stepping motors are working differentially is introduced. Such valve changes the fluid flow proportionally to the sum or difference of the motors' steps numbers. The valve design and principle of its operation is described. Theoretical equations and simulation models are proposed for all elements of the drive, i.e., the stepping motor units, hydraulic valve and cylinder. The main features of the valve and drive operation are described; some specific problem areas covering the nature of stepping motors and their differential work in the valve are also considered. The whole servo drive non-linear model is proposed and used further for simulation investigations. The initial simulation investigations of the drive with a new valve have shown that there is a significant overshoot in the drive step response, which is not allowed in positioning process. Therefore additional effort is spent to reduce the overshoot and in consequence reduce the settling time. A special predictive algorithm is proposed to this end. Then the proposed control method is tested and further improved in simulations. Further on, the model is implemented in reality and the whole servo drive system is tested. The investigation results presented in this paper, are showing an overshoot-free positioning process which enables high positioning accuracy.
Network Flow Simulation of Fluid Transients in Rocket Propulsion Systems
NASA Technical Reports Server (NTRS)
Bandyopadhyay, Alak; Hamill, Brian; Ramachandran, Narayanan; Majumdar, Alok
2011-01-01
Fluid transients, also known as water hammer, can have a significant impact on the design and operation of both spacecraft and launch vehicle propulsion systems. These transients often occur at system activation and shutdown. The pressure rise due to sudden opening and closing of valves of propulsion feed lines can cause serious damage during activation and shutdown of propulsion systems. During activation (valve opening) and shutdown (valve closing), pressure surges must be predicted accurately to ensure structural integrity of the propulsion system fluid network. In the current work, a network flow simulation software (Generalized Fluid System Simulation Program) based on Finite Volume Method has been used to predict the pressure surges in the feed line due to both valve closing and valve opening using two separate geometrical configurations. The valve opening pressure surge results are compared with experimental data available in the literature and the numerical results compared very well within reasonable accuracy (< 5%) for a wide range of inlet-to-initial pressure ratios. A Fast Fourier Transform is preformed on the pressure oscillations to predict the various modal frequencies of the pressure wave. The shutdown problem, i.e. valve closing problem, the simulation results are compared with the results of Method of Characteristics. Most rocket engines experience a longitudinal acceleration, known as "pogo" during the later stage of engine burn. In the shutdown example problem, an accumulator has been used in the feed system to demonstrate the "pogo" mitigation effects in the feed system of propellant. The simulation results using GFSSP compared very well with the results of Method of Characteristics.
MEMS Micro-Valve for Space Applications
NASA Technical Reports Server (NTRS)
Chakraborty, I.; Tang, W. C.; Bame, D. P.; Tang, T. K.
1998-01-01
We report on the development of a Micro-ElectroMechanical Systems (MEMS) valve that is designed to meet the rigorous performance requirements for a variety of space applications, such as micropropulsion, in-situ chemical analysis of other planets, or micro-fluidics experiments in micro-gravity. These systems often require very small yet reliable silicon valves with extremely low leak rates and long shelf lives. Also, they must survive the perils of space travel, which include unstoppable radiation, monumental shock and vibration forces, as well as extreme variations in temperature. Currently, no commercial MEMS valve meets these requirements. We at JPL are developing a piezoelectric MEMS valve that attempts to address the unique problem of space. We begin with proven configurations that may seem familiar. However, we have implemented some major design innovations that should produce a superior valve. The JPL micro-valve is expected to have an extremely low leak rate, limited susceptibility to particulates, vibration or radiation, as well as a wide operational temperature range.
Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan
2015-12-14
Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.
Bouma, Hjalmar R; Mungroop, Hubert E; de Geus, A Fred; Huisman, Daniel D; Nijsten, Maarten W N; Mariani, Massimo A; Scheeren, Thomas W L; Burgerhof, Johannes G M; Henning, Robert H; Epema, Anne H
2018-03-01
Perioperative acute kidney injury (AKI) is an important predictor of long-term all-cause mortality after coronary artery bypass (CABG). However, the effect of AKI on long-term mortality after cardiac valve operations is hitherto undocumented. Perioperative renal injury and long-term all-cause mortality after valve operations were studied in a prospective cohort of patients undergoing solitary valve operations (n=2,806) or valve operations combined with CABG (n=1,260) with up to 18 years of follow-up. Postoperative serum creatinine increase was classified according to AKI 0-3. Patients undergoing solitary CABG (n=4,938) with cardiopulmonary bypass served as reference. In both valve and valve+CABG operations, postoperative renal injury of AKI stage 1 or higher was progressively associated with an increase in long-term mortality (HR 2.27, p<0.05 for valve; HR 1.65, p<0.05 for valve operations combined with CABG; HR 1.56, p<0.05 for CABG). Notably, the mortality risk increased already substantially at serum creatinine rises of 10-25%, i.e. far below the threshold for AKI stage 1 after valve operations (HR 1.39, p<0.05), but not after valve operations combined with CABG or CABG only. An increase in serum creatinine by more than 10%during the first week following valve operation is associated with an increased risk for long-term mortality following cardiac valve operation. Thus, AKI-classification clearly underestimates long-term mortality risk in patients undergoing valve operations. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Perceval S aortic valve implantation in an achondroplastic Dwarf
Baikoussis, Nikolaos G.; Argiriou, Michalis; Argiriou, Orestis; Dedeilias, Panagiotis
2016-01-01
Despite cardiovascular disease in patients with dwarfism is not rare; there is a lack of reports referring to cardiac interventions in such patients. Dwarfism may be due to achondroplasia or hormonal growth disorders. We present a 58-year-old woman with episodes of dyspnea for several months. She underwent on transthoracic echocardiography, and she diagnosed with severe aortic valve stenosis. She referred to our department for surgical treatment of this finding. In accordance of her anthropometric characteristics and her very small aortic annulus, we had the dilemma of prosthesis selection. We decided to implant a stentless valve to optimize her effective orifice area. Our aim is to present the successful Perceval S valve implantation and the descriptions of the problems coming across in operating on these special patients. To our knowledge, this is the first case patient in which a Perceval S valve is implanted according to the international bibliography. PMID:26750695
Remote manual operator for space station intermodule ventilation valve
NASA Technical Reports Server (NTRS)
Guyaux, James R.
1996-01-01
The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.
Guidelines for glycol dehydrator design; Part 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manning, W.P.; Wood, H.S.
1993-01-01
Better designs and instrumentation improve glycol dehydrator performance. This paper reports on these guidelines which emphasize efficient water removal from natural gas. Water, a common contaminant in natural gas, causes operational problems when it forms hydrates and deposits on solid surfaces. Result: plugged valves, meters, instruments and even pipelines. Simple rules resolve these problems and reduce downtime and maintenance costs.
Description of the NACA Universal Test Engine and Some Test Results
NASA Technical Reports Server (NTRS)
Ware, Marsden
1927-01-01
This report describes the 5-inch bore by 7-inch stroke single cylinder test engine used at the Langley Field Laboratory of the National Advisory Committee for Aeronautics in laboratory research on internal-combustion engine problems and presents some results of tests made therewith. The engine is arranged for variation over wide ranges, of the compression ratio and lift and timing of both inlet and exhaust valves while the engine is in operation. Provision is also made for the connection of a number of auxiliaries. These features tend to make the engine universal in character, and especially suited for the study of certain problems involving change in compression ratio, valve timing, and lift.
Ross operation in children: late results.
Elkins, R C; Lane, M M; McCue, C
2001-11-01
Although the Ross operation has become the accepted aortic valve replacement in children, the long-term fate of the pulmonary autograft valve remains unknown. To assess mid-term and late results of autograft valve durability, patient survival and valve-related morbidity, a retrospective review of patients (age range: 3 days to 17 years) having a Ross operation between November 1986 and May 2001 were reviewed. Medical records and patient contacts with all but two of 167 current survivors of 178 consecutive patients having an aortic valve replacement as a Ross operation have been completed during the past two years. The most recent echocardiographic evaluation was reviewed for autograft valve and homograft valve function. Operative mortality was 4.5% (8/178), with three late deaths (two were non-valve-related) for an actuarial survival of 92+/-3% at 12 years. Actuarial freedom from autograft valve degeneration (reoperation or severe insufficiency of autograft valve or valve-related death) was 90+/-4% at 12 years. Autograft valve degeneration was not affected by technique of insertion (141 root replacement, 37 intra-aortic), aortic valve morphology (157 bicuspid or unicuspid, 26 tricuspid), or age at operation. Autograft valve degeneration was worse in patients with a primary lesion of aortic insufficiency than in those with aortic stenosis (p = 0.03). Autograft valve reoperation was required in 12 patients, with autograft valve replacement in seven. Actuarial freedom from autograft replacement was 93+/-3% at 12 years. Homograft valve replacement was required in seven patients, with actuarial freedom from replacement of 90+/-4% at 12 years. Eight additional patients have homograft valve obstruction (gradient > or =50 mmHg), and seven have severe pulmonary insufficiency. Survival and freedom from aortic valve replacement are excellent in children. Homograft valve late function remains a concern, and efforts to improve homograft durability should be encouraged.
A Genomics-Based Model for Prediction of Severe Bioprosthetic Mitral Valve Calcification.
Ponasenko, Anastasia V; Khutornaya, Maria V; Kutikhin, Anton G; Rutkovskaya, Natalia V; Tsepokina, Anna V; Kondyukova, Natalia V; Yuzhalin, Arseniy E; Barbarash, Leonid S
2016-08-31
Severe bioprosthetic mitral valve calcification is a significant problem in cardiovascular surgery. Unfortunately, clinical markers did not demonstrate efficacy in prediction of severe bioprosthetic mitral valve calcification. Here, we examined whether a genomics-based approach is efficient in predicting the risk of severe bioprosthetic mitral valve calcification. A total of 124 consecutive Russian patients who underwent mitral valve replacement surgery were recruited. We investigated the associations of the inherited variation in innate immunity, lipid metabolism and calcium metabolism genes with severe bioprosthetic mitral valve calcification. Genotyping was conducted utilizing the TaqMan assay. Eight gene polymorphisms were significantly associated with severe bioprosthetic mitral valve calcification and were therefore included into stepwise logistic regression which identified male gender, the T/T genotype of the rs3775073 polymorphism within the TLR6 gene, the C/T genotype of the rs2229238 polymorphism within the IL6R gene, and the A/A genotype of the rs10455872 polymorphism within the LPA gene as independent predictors of severe bioprosthetic mitral valve calcification. The developed genomics-based model had fair predictive value with area under the receiver operating characteristic (ROC) curve of 0.73. In conclusion, our genomics-based approach is efficient for the prediction of severe bioprosthetic mitral valve calcification.
A Genomics-Based Model for Prediction of Severe Bioprosthetic Mitral Valve Calcification
Ponasenko, Anastasia V.; Khutornaya, Maria V.; Kutikhin, Anton G.; Rutkovskaya, Natalia V.; Tsepokina, Anna V.; Kondyukova, Natalia V.; Yuzhalin, Arseniy E.; Barbarash, Leonid S.
2016-01-01
Severe bioprosthetic mitral valve calcification is a significant problem in cardiovascular surgery. Unfortunately, clinical markers did not demonstrate efficacy in prediction of severe bioprosthetic mitral valve calcification. Here, we examined whether a genomics-based approach is efficient in predicting the risk of severe bioprosthetic mitral valve calcification. A total of 124 consecutive Russian patients who underwent mitral valve replacement surgery were recruited. We investigated the associations of the inherited variation in innate immunity, lipid metabolism and calcium metabolism genes with severe bioprosthetic mitral valve calcification. Genotyping was conducted utilizing the TaqMan assay. Eight gene polymorphisms were significantly associated with severe bioprosthetic mitral valve calcification and were therefore included into stepwise logistic regression which identified male gender, the T/T genotype of the rs3775073 polymorphism within the TLR6 gene, the C/T genotype of the rs2229238 polymorphism within the IL6R gene, and the A/A genotype of the rs10455872 polymorphism within the LPA gene as independent predictors of severe bioprosthetic mitral valve calcification. The developed genomics-based model had fair predictive value with area under the receiver operating characteristic (ROC) curve of 0.73. In conclusion, our genomics-based approach is efficient for the prediction of severe bioprosthetic mitral valve calcification. PMID:27589735
Kawahito, Tomohisa; Egawa, Yoshiyasu; Yoshida, Homare; Shimoe, Yasushi; Onishi, Tatsuya; Miyagi, Yuhichi; Terada, Kazuya; Ohta, Akira
2015-07-01
A 24-day-old boy suddenly developed progressive heart failure and was transported to our hospital. Echocardiography showed massive mitral regurgitation due to chordal rupture. Mitral valve repair was performed at 28 days of life, but postoperative valvular function was not satisfactory. A mechanical valve was implanted in the supra-annular position at 37 days of life. Two months after valve replacement, the mechanical valve was suddenly stuck. Emergent redo valve replacement was performed, but the prosthetic valve became stuck again 2 months after the 3rd operation, despite sufficient anti-coagulation therapy. At the 4th operation (6 months after birth), we implanted a pulmonary autograft in the mitral position instead of another mechanical valve in an emergent operation. The right ventricular outflow tract was reconstructed with a valved conduit. A postoperative catheter examination, which was performed 1 year after the Ross II operation, showed mild mitral stenosis with no regurgitation. Previous reports of Ross II operations in infants are rare and long-term results are unknown. However, we advocate that this procedure should be a rescue operation for mitral valve dysfunction in the early period of infants.
46 CFR 56.20-9 - Valve construction.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...
46 CFR 56.20-9 - Valve construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...
46 CFR 56.20-9 - Valve construction.
Code of Federal Regulations, 2012 CFR
2012-10-01
...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...
46 CFR 56.20-9 - Valve construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) motion of the handwheel or operating lever as seen by one facing the end of the valve stem. Each gate, globe, and angle valve must generally be of the rising-stem type, preferably with the stem threads... nonrising-stem valve will be acceptable. Each nonrising-stem valve, lever-operated valve, or other valve...
Check valve installation in pilot operated relief valve prevents reverse pressurization
NASA Technical Reports Server (NTRS)
Oswalt, L.
1966-01-01
Two check valves prevent reverse flow through pilot-operated relief valves of differential area piston design. Title valves control pressure flow to ensure that the piston dome pressure is always at least as great as the main relief valve discharge pressure.
Outcomes After Operations for Unicuspid Aortic Valve With or Without Ascending Repair in Adults
Zhu, Yuanjia; Roselli, Eric E.; Idrees, Jay J.; Wojnarski, Charles M.; Griffin, Brian; Kalahasti, Vidyasagar; Pettersson, Gosta; Svensson, Lars G.
2016-01-01
Background Unicuspid aortic valve is an important subset of bicuspid aortic valve, and knowledge regarding its aortopathy pattern and surgical outcomes is limited. Our objectives were to characterize unicuspid aortic valve patients, associated aortopathy, and surgical outcomes. Methods From January 1990 to May 2013, 149 adult unicuspid aortic valve patients underwent aortic valve replacement or repair for aortic stenosis (n = 13), regurgitation (n = 13), or both (n = 123), and in 91 (61%) the aortic valve operation was combined with aortic repair. Data were obtained from the Cardiovascular Information Registry and medical record review. Three-dimensional imaging analysis was performed from preoperative computed tomography and magnetic resonance imaging scans. The Kaplan-Meier method was used for survival analysis. Results Patients had a mean maximum aortic diameter of 44 ± 8 mm and variably involved the aortic root, ascending, or arch, or both. Patients with valve operations alone were more likely to be hypertensive (p = 0.01) and to have severe aortic stenosis (p = 0.07) than those who underwent concurrent aortic operations. There were no operative deaths, strokes, or myocardial infarctions. Patients undergoing aortic repair had better long-term survival. Estimated survival at 1, 5, and 10 years was 100%, 100%, and 100% after combined operations and was 100%, 88%, and 88% after valve operations alone (p = 0.01). Conclusions Patients with a dysfunctional unicuspid aortic valve frequently present with an ascending aneurysm that requires repair. Combined aortic valve operations and aortic repair was associated with significantly better long-term survival than a valve operation alone. Further study of this association may direct decisions about timing of surgical intervention. PMID:26453423
Yoneyama, Fumiya; Okamura, Toru; Harada, Yorikazu; Okita, Yutaka
2018-02-01
A 13-year-old male presented with neoaortic root dilatation and severe aortic valve regurgitation 13 years following an arterial switch operation. The valve cusps were unbalanced due to an enlarged non-coronary cusp. A valve-sparing reimplantation with a cusp plication was performed which resulted in a competent valve with trivial regurgitation. Thus, even in an unbalanced cusp, valve-sparing reimplantation can be used for neoaortic root dilatation and valve regurgitation after an arterial switch operation. © 2018 Wiley Periodicals, Inc.
Effect of prior aortic valve intervention on results of the Ross operation.
Sakaguchi, Hidehito; Elkins, Ronald C; Lane, Mary M; McCue, Carolyn
2003-07-01
Patient-related factors, aortic insufficiency, bicuspid aortic valve, aortic annulus dilatation, ascending aortic dilatation or aneurysm, and aortic valve endocarditis have been suggested as affecting the results of the Ross operation. The study aim was to assess the impact of prior aortic valve intervention on early and late results of a Ross operation. A total of 399 patients who underwent surgery between August 1986 and September 2000 were reviewed retrospectively. The patients were grouped as: no prior aortic valve intervention (NOAVI, n = 219); prior aortic valvuloplasty (AVP, n = 106); prior balloon aortic valvuloplasty (AVB, n = 40); and prior aortic valve replacement (AVR, n = 34). Details of operative and late mortality, autograft valve function, and homograft valve function were analyzed. Operative mortality was higher for AVB (10%; three deaths in neonates) than the other groups (from 2.3% to 5.9%) (p = 0.084). Freedom from autograft valve degeneration, defined as severe autograft valve insufficiency, non-endocarditis autograft valve reoperation or valve-related death, ranged from 93 +/- 3% for AVP to 76 +/- 8% for NOAVI at 10 years (p = 0.43). Freedom from homograft reoperation in the pulmonary position was 100% for AVB at six years, and 99 +/- 1% for AVP, 82 +/- 8% for NOAVI, and 70 +/- 13% for AVR at 10 years (p = 0.0026). There appears to be no significant difference between patients with and without prior aortic valve surgery, with respect to operative mortality or late autograft function. However, patients with prior AVR appear to have a significantly higher homograft reoperation rate after a Ross operation, the reasons for which are uncertain.
NASA Astrophysics Data System (ADS)
Matsuoka, Ken; Esumi, Motoki; Ikeguchi, Ken Bryan; Kasahara, Jiro; Matsuo, Akiko; Funaki, Ikkoh
We developed a novel coaxial rotary valve for a multi-tube PDE. Since this single valve can supply three different gases (fuel, oxidizer and purge gas) into a combustor, the unification of the valve systems for three different gases is possible by using our newly designed valve. A PDRE system can be simple and lightweight by using this valve, and thus its thrust-weight ratio can be increased. We proposed the design of a multi-tube rotary-valved PDRE system by this rotary valve. Moreover, in preparation for a multi-tube rotary-valved PDRE, we carried out the multi-cycle operation experiment by the single-tube rotary-valved PDRE system. The combustion wave velocity was measured to confirm the operation of the PDRE system. Deflagration-to-detonation transition (DDT) was confirmed and DDT distance decreased under the condition of high operation frequency. In addition, a maximum operation frequency was 159 Hz.
Modification and performance evaluation of a mono-valve engine
NASA Astrophysics Data System (ADS)
Behrens, Justin W.
A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bond, N.D.
1982-05-01
This report covers the development of the various letdown valves used for the two-stage high pressure and temperature coal slurry letdown system as used at the H-Coal Pilot Plant. The period covered in this report was from the prestart-up oil circulation through Coal Runs No. 1 - No. 7. The valves covered are the Willis, which was used exclusively from Coal Runs No. 1 - No. 5, the Cameron and the Kieley and Mueller. The LV-202B Kieley and Mueller and LV-204B Cameron valves again showed little valve wear during short Coal Run No. 7, which demonstrates that the full potentialmore » of these valve designs has not been achieved yet. The problem with the Kieley and Mueller plug freezing will be looked at further, with addition of grease ports and a possible new designed plug shaft and stem guide being made for the valve. The Willis valves developed the same body leaks around the bonnet areas that occurred during Coal Run No. 6. This will be looked at before Coal Run No. 8, but no further trim development is planned. To summarize the progress of the LV-202 and LV-204 valves, the Willis was developed to last about 100 hours, which is the expected life for this valve design in our coal liquefaction process; whereas, the Cameron and Kieley and Mueller valves have lasted for days with good results. The Cameron and Kieley and Mueller valves still have not reached their full potential in plant operation, and, along with the new Masoneilan Sasol, Masoneilan Prototype, Hammel Dahl and Paul valves, future progress in Coal Run No. 8 for the high pressure and temperature letdown valves is anticipated.« less
Evaluation of a high response electrohydraulic digital control valve
NASA Technical Reports Server (NTRS)
Anderson, R. L.
1973-01-01
The application is described of a digital control valve on an electrohydraulic servo actuator. The digital control problem is discussed in general as well as the design and evaluation of a breadboard actuator. The evaluation revealed a number of problems associated with matching the valve to a hydraulic load. The problems were related to lost motion resulting from bulk modulus and leakage. These problems were effectively minimized in the breadboard actuator by maintaining a 1000 psi back pressure on the valve circuit and thereby improving the effective bulk modulus.
Remotely operated high pressure valve protects test personnel
NASA Technical Reports Server (NTRS)
Howland, B. T.
1967-01-01
High pressure valve used in testing certain spacecraft systems is safely opened and closed by a remotely stationed operator. The valve is self-regulating in that if the incoming pressure drops below a desired value the valve will automatically close, warning the operator that the testing pressure has dropped to an undesired level.
Method and system for measuring gate valve clearances and seating force
Casada, Donald A.; Haynes, Howard D.; Moyers, John C.; Stewart, Brian K.
1996-01-01
Valve clearances and seating force, as well as other valve operational parameters, are determined by measuring valve stem rotation during opening and closing operations of a translatable gate valve. The magnitude of the stem rotation, and the relative difference between the stem rotation on opening and closing provides valuable data on the valve internals in a non-intrusive manner.
A shut-off valve for flexible tubing
NASA Technical Reports Server (NTRS)
Reyburn, W. W.
1972-01-01
Design of light weight valve for flexible tubing is described. Valve is hand operated and provides positive sealing in normally closed position. Diagram is provided to show construction of valve. Principles of operation are explained.
[Late complications following Björk-Shiley and St. Jude Medical heart valve replacement].
Horstkotte, D; Körfer, R; Budde, T; Haerten, K; Schulte, H D; Bircks, W; Loogen, F
1983-05-01
Valve-related complications after Björk-Shiley mitral (n = 475), aortic (n = 424), or mitral-aortic implantation (n = 119) were compared to complications after St. Jude mitral (n = 173), aortic (n = 152), and St. Jude mitral and aortic (n = 63) replacements. The 1,018 consecutive patients with Björk-Shiley valves had been operated upon between 1974 and 1982, those with St. Jude valves between 1978 and 1982. All patients were placed on anticoagulant therapy with phenprocoumon early after operation and no significant intergroup differences in the effectiveness of the anticoagulant therapy were found. At a comparable follow-up time of approximately 23 months, 24 major thromboembolic episodes were observed after Björk-Shiley mitral (BSM) and 3 after St. Jude mitral valve implantation (SJM), corresponding to a thromboembolic rate of 2.82/100 patient years with BSM and 0.93/100 patient years with SJM. After aortic valve replacements, 1.93 events in 100 patient years occurred after Björk-Shiley aortic (BSA) and 0.73 after St. Jude aortic implantation (SJA). In patients with double valve replacements, these rates were 3.2 (BSM + BSA) and 0.88 (SJM + SJA), respectively. The cerebral vessels were involved in 52% and the arteries of the extremities in 22% of these major events. Six Björk-Shiley prostheses had to be replaced because of valve thrombosis. The overall incidence of severe hemorrhagic complications was 2.94/100 patient years in BSM and 1.79 in SJM. After aortic valve replacement, we found rates of 1.80/100 patient years (BSA) and 2.57/100 patient years (SJA), respectively. Intravascular hemolysis no longer seems to be a significant clinical problem. However, indications of red cell damage after heart valve replacement were significantly greater in patients with perivalvular leakage, valve thrombosis, or dysfunction than in those with normally functioning prostheses. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with concomitant perivalvular regurgitation (0.46%). One valve had to be replaced because of fracture of the outlet strut of a BSM prosthesis. Hemorrhage due to the anticoagulant treatment was thus the most frequent complication, without significant intergroup differences, while thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude implantation. This may lead to the consideration of a change in the prophylaxis of thrombus formations with the St. Jude valve, especially in aortic valve replacements with sinus rhythm.
Magnetically operated check valve
NASA Technical Reports Server (NTRS)
Morris, Brian G. (Inventor); Bozeman, Richard J., Jr. (Inventor)
1994-01-01
A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.
Magnetically operated check valve
NASA Astrophysics Data System (ADS)
Morris, Brian G.; Bozeman, Richard J., Jr.
1994-06-01
A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.
Operational durability of a giant ER valve for Braille display
NASA Astrophysics Data System (ADS)
Luning, Xu; Han, Li; Yufei, Li; Shen, Rong; Kunquan, Lu
2017-05-01
The compact configuration of giant ER (electrorheological) valves provides the possibility of realizing a full-page Braille display. The operational durability of ER valves is a key issue in fulfilling a Braille display. A giant ER valve was used to investigate the variations in pressure drops and critical pressure drops of the valves over a long period under some typical operational parameters. The results indicate that neither the pressure drops nor critical pressure drops of giant ER valves show apparent deterioration over a long period. Without ER fluid exchange, a blockage appears in the channel of the valve because the ER structures induced by an external electric field cannot be broken by the Brownian motion of hydraulic oil molecules when the external electric field is removed. Forcing ER fluid flow is an effective and necessary method to keep the channel of the valve unblocked. Thus the operational durability of the valve using giant ER fluids is able to meet the demands of Braille display.
Method and system for measuring gate valve clearances and seating force
Casada, D.A.; Haynes, H.D.; Moyers, J.C.; Stewart, B.K.
1996-01-30
Valve clearances and seating force, as well as other valve operational parameters, are determined by measuring valve stem rotation during opening and closing operations of a translatable gate valve. The magnitude of the stem rotation, and the relative difference between the stem rotation on opening and closing provides valuable data on the valve internals in a non-intrusive manner. 8 figs.
NASA Astrophysics Data System (ADS)
Zhao, Jianhua; Zhou, Songlin; Lu, Xianghui; Gao, Dianrong
2015-09-01
The double flapper-nozzle servo valve is widely used to launch and guide the equipment. Due to the large instantaneous flow rate of servo valve working under specific operating conditions, the temperature of servo valve would reach 120°C and the valve core and valve sleeve deform in a short amount of time. So the control precision of servo valve significantly decreases and the clamping stagnation phenomenon of valve core appears. In order to solve the problem of degraded control accuracy and clamping stagnation of servo valve under large temperature difference circumstance, the numerical simulation of heat-fluid-solid coupling by using finite element method is done. The simulation result shows that zero position leakage of servo valve is basically impacted by oil temperature and change of fit clearance. The clamping stagnation is caused by warpage-deformation and fit clearance reduction of the valve core and valve sleeve. The distribution rules of the temperature and thermal-deformation of shell, valve core and valve sleeve and the pressure, velocity and temperature field of flow channel are also analyzed. Zero position leakage and electromagnet's current when valve core moves in full-stroke are tested using Electro-hydraulic Servo-valve Characteristic Test-bed of an aerospace sciences and technology corporation. The experimental results show that the change law of experimental current at different oil temperatures is roughly identical to simulation current. The current curve of the electromagnet is smooth when oil temperature is below 80°C, but the amplitude of current significantly increases and the hairy appears when oil temperature is above 80°C. The current becomes smooth again after the warped valve core and valve sleeve are reground. It indicates that clamping stagnation is caused by warpage-deformation and fit clearance reduction of valve core and valve sleeve. This paper simulates and tests the heat-fluid-solid coupling of double flapper-nozzle servo valve, and the obtained results provide the reference value for the design of double flapper-nozzle force feedback servo valve.
Tsai, I-Chen; Lin, Yung-Kai; Chang, Yen; Fu, Yun-Ching; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen; Jan, Sheng-Ling; Wang, Kuo-Yang; Chen, Min-Chi; Chen, Clayton Chi-Chang
2009-04-01
The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Björk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders.
Durability Tests of Ball Valve Prototype with Flowmeter Operation
NASA Astrophysics Data System (ADS)
Rogula, J.; Romanik, G.
2018-02-01
The results of the investigation of the prototypical ball valve are presented in this article. The innovation of the tested valve is a ball with a built-in measuring orifice. The valve has been subjected to durability tests. Leakage under three temperatures: ambient, -30°C and +100°C was analyzed. Sealing elements of the valve were tested for roughness and deviation of shape before and after the cycles of operation. Ball valve operation means cycles of open/close. It was planned to perform 1000 cycles at each temperature condition accordingly. Tests of the valve were performed under gas pressure equal to 10 MPa. The research was carried out under the Operational Program "Intelligent Development" (POIR 01.01.01-00-0013 / 15 "Development of devices for measurement of media flow on industrial trunk-lines".
NASA Technical Reports Server (NTRS)
Friedell, M. V.
1980-01-01
Wrench converts gripping action of hand to rotary motion without imparting reactive moments or forces on part being turned or on operator. Wrench should be useful in undersea operations and other delicate work where reactive forces and torques have to be controlled. In design for valve tightening, tool resembles cross between conventional spanner wrench and pilers. One handle engages valve body; second handle has ratchet pawl that engages toothed coupling ring on perimeter of valve handle. When operator squeezes wrench handles, valve handle rotates with respect to valve body.
NASA Astrophysics Data System (ADS)
Zaryankin, A. E.; Rogalev, N. D.; Rogalev, A. N.; Garanin, I. V.; Osipov, S. K.; Grigoriev, E. Yu.
2016-06-01
This paper considers the problems that will unavoidably be encountered in the creation of new-generation turbines operated at ultrasupercritical initial steam parameters, namely, the development of new control and shutoff valves, the reduction of end energy losses in blade cascades and steam leaks in high-pressure cylinders (HPCs), the elimination of effect produced by regenerative steam bleedoffs on the afterextraction stage, the cooling of a blade cascade, etc. Some possible solutions are given for the two first of the listed problems. The conclusion about the need for the transition to new-generation control valves in the development of new advanced steam turbines with ultrasupercritical initial steam parameters has been made. From the viewpoint of their design, the considered new-generation valves differ from the known contemporary constructions by a shaped axially symmetric confusor channel and perforated zones on the streamlined spool surface and the inlet diffuser saddle part. The analysis of the vibration behavior of new-generation valves has demonstrated a decrease in the dynamic loads acting on their stems. To reduce the end energy losses in nozzle or blade cascades with small aspect ratios, it is proposed to use finned shrouds in the interblade channels. The cross section of fins has a triangular profile, and their height must be comparable with the thickness of the boundary layer in the outlet cross section of a cascade and, provisionally, be smaller than 8% of the cascade chord.
Mechanical valve replacement in congenital heart disease.
Fiane, A E; Lindberg, H L; Saatvedt, K; Svennevig, J L
1996-05-01
Mechanical valves are the prosthesis of choice in valve replacement in children. However, the problem of somatic growth leading to patient-valve mismatch remains present, and the appropriate anticoagulation regimen remains controversial. We present our experience of valve replacement in a young population over 20 years. Between 1972 and 1992, 48 patients (34 males and 14 females), mean age 11.2 years (range 0.4-27.4 years), underwent mechanical valve replacement at our institution. Aortic valve replacement was performed in 28 patients (58.3%), mitral valve replacement in 13 (27.1%), tricuspid valve replacement in six (12.5%) and pulmonary valve replacement in one patient (2.1%). The prostheses used were: St. Jude Medical (n = 2), Björk-Shiley (n = 14), Medtronic Hall (n = 16), Duromedics (n = 2) and CarboMedics (n = 14). Early mortality was 14.3%, 10.7% for aortic valve replacement and 30.8% for mitral valve replacement. Mean follow up for all patients was 8.3 years (range 0-22 years), with a total of 398 patient-years. Seven patients died during the follow up (17.1%). Survival after 10 years, including operative mortality, was 81% for aortic valve replacement, 33% for mitral valve replacement, 83% for tricuspid valve replacement and 100% for pulmonary valve replacement. All patients were anticoagulated with warfarin. In eight patients (16.7%) an antiplatelet drug (aspirin or dipyridamole) was added. Major events included paravalvular leak in six patients (1.5%/pty), valve thrombosis in five (mitral position in two, tricuspid in three) (1.3%/pty) and endocarditis in one patient (0.3%/pty). Minor thromboembolic events occurred in three patients (0.8%/pty) and minor hemorrhagic events in three (0.8%/pty). No patients developed hemolytic anemia and there was no case of structural failure. In our experience, mechanical prostheses in congenital heart disease were associated with significant morbidity and mortality, however long term survival after aortic valve replacement was good (81% at 10 years). Thromboembolic and hemorrhagic events were of minor significance. Atrio-ventricular valve replacement carried the highest risk of valve thrombosis and we now give warfarin and an antiplatelet drug to children undergoing mechanical valve implantation in this position.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richins, W.D.; Snow, S.D.; Miller, G.K.
1995-12-01
Some motor operated valves now have higher torque switch settings due to regulatory requirements to ensure valve operability with appropriate margins at design basis conditions. Verifying operability with these settings imposes higher stem loads during periodic inservice testing. These higher test loads increase stresses in the various valve internal parts which may in turn increase the fatigue usage factors. This increased fatigue is judged to be a concern primarily in the valve disks, seats, yokes, stems, and stem nuts. Although the motor operators may also have significantly increased loading, they are being evaluated by the manufacturers and are beyond themore » scope of this study. Two gate valves representative of both relatively weak and strong valves commonly used in commercial nuclear applications were selected for fatigue analyses. Detailed dimensional and test data were available for both valves from previous studies at the Idaho National Engineering Laboratory. Finite element models were developed to estimate maximum stresses in the internal parts of the valves and to identity the critical areas within the valves where fatigue may be a concern. Loads were estimated using industry standard equations for calculating torque switch settings prior and subsequent to the testing requirements of USNRC Generic Letter 89--10. Test data were used to determine both; (1) the overshoot load between torque switch trip and final seating of the disk during valve closing and (2) the stem thrust required to open the valves. The ranges of peak stresses thus determined were then used to estimate the increase in the fatigue usage factors due to the higher stem thrust loads. The usages that would be accumulated by 100 base cycles plus one or eight test cycles per year over 40 and 60 years of operation were calculated.« less
Statistical Performance Evaluation Of Soft Seat Pressure Relief Valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harris, Stephen P.; Gross, Robert E.
2013-03-26
Risk-based inspection methods enable estimation of the probability of failure on demand for spring-operated pressure relief valves at the United States Department of Energy's Savannah River Site in Aiken, South Carolina. This paper presents a statistical performance evaluation of soft seat spring operated pressure relief valves. These pressure relief valves are typically smaller and of lower cost than hard seat (metal to metal) pressure relief valves and can provide substantial cost savings in fluid service applications (air, gas, liquid, and steam) providing that probability of failure on demand (the probability that the pressure relief valve fails to perform its intendedmore » safety function during a potentially dangerous over pressurization) is at least as good as that for hard seat valves. The research in this paper shows that the proportion of soft seat spring operated pressure relief valves failing is the same or less than that of hard seat valves, and that for failed valves, soft seat valves typically have failure ratios of proof test pressure to set pressure less than that of hard seat valves.« less
Control of soft machines using actuators operated by a Braille display.
Mosadegh, Bobak; Mazzeo, Aaron D; Shepherd, Robert F; Morin, Stephen A; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M
2014-01-07
One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds-often built for a single purpose-are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled Braille display and a micropneumatic device. The Braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface.
Control of Soft Machines using Actuators Operated by a Braille Display
Mosadegh, Bobak; Mazzeo, Aaron D.; Shepherd, Robert F.; Morin, Stephen A.; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M.
2013-01-01
One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds—often built for a single purpose—are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled braille display and a micropneumatic device. The braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface. PMID:24196070
Magnetically operated check valve
NASA Astrophysics Data System (ADS)
Morris, Brian G.; Bozeman, Richard J., Jr.
1993-03-01
A magnetically operated check valve is disclosed having, in one aspect, a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1982-04-30
The work done to extend the existing drain-down valve technology to provide passive drain-down freeze protection for thermosyphon-based solar water heaters is described. The basic design of the existing valve model is that of a spool valve, employing a cylindrical spool which moves axially in a mating cartridge to open and close o-rings at the two operating extremes (drain and operate) to perform the valving function. Three passive actuators to drive the basic valving mechanism were designed, fabricated, and tested. Two piping configurations used to integrate the spool valve with the thermosyphon system are described, as are the passive actuators.more » The three actuator designs are: photovoltaic driven, refrigerant-based bellows, and heat motor cable-drive designs. Costs are compared for the alternative actuator designs, and operating characteristics were examined for the thermosyphon system, including field tests. The market for the valve for thermosyphon systems is then assessed. (LEW)« less
Park, Jong-Myeon; Cho, Yoon-Kyoung; Lee, Beom-Seok; Lee, Jeong-Gun; Ko, Christopher
2007-05-01
Valving is critical in microfluidic systems. Among many innovative microvalves used in lab-on-a-chip applications, phase change based microvalves using paraffin wax are particularly attractive for disposable biochip applications because they are simple to implement, cost-effective and biocompatible. However, previously reported paraffin-based valves require embedded microheaters and therefore multi-step operation of many microvalves was a difficult problem. Besides, the operation time was relatively long, 2-10 s. In this paper, we report a unique phase change based microvalve for rapid and versatile operation of multiple microvalves using a single laser diode. The valve is made of nanocomposite materials in which 10 nm-sized iron oxide nanoparticles are dispersed in paraffin wax and used as nanoheaters when excited by laser irradiation. Laser light of relatively weak intensity was able to melt the paraffin wax with the embedded iron oxide nanoparticles, whereas even a very intense laser beam does not melt wax alone. The microvalves are leak-free up to 403.0 +/- 7.6 kPa and the response times to operate both normally closed and normally opened microvalves are less than 0.5 s. Furthermore, a sequential operation of multiple microvalves on a centrifugal microfluidic device using a single laser diode was demonstrated. It showed that the optical control of multiple microvalves is fast, robust, simple to operate, and requires minimal chip space and thus is well suited for fully integrated lab-on-a-chip applications.
All metal valve structure for gas systems
Baker, Ray W.; Pawlak, Donald A.; Ramey, Alford J.
1984-11-13
A valve assembly with a resilient metal seat member is disclosed for providing a gas-tight seal in a gas handling system. The valve assembly also includes a valve element for sealing against the valve seat member; and an actuating means for operating the valve element. The valve seat member is a one-piece stainless steel ring having a central valve port and peripheral mounting flange, and an annular corrugation in between. A groove between the first and second ridges serves as a flexure zone during operation of the valve member and thus provides the seating pressure between the inner ridge or valve seat and the valve element. The outer annular ridge has a diameter less than said valve element to limit the seating motion of the valve element, preventing non-elastic deformation of the seat member.
All-metal valve structure for gas systems
Baker, R.W.; Pawlak, D.A.; Ramey, A.J.
1982-06-10
A valve assembly with a resilient metal seat member is disclosed for providing a gas-tight seal in a gas handling system. The valve assembly also includes a valve element for sealing against the valve seat member; and an actuating means for operating the valve element. The valve seat member is a one-piece stainless steel ring having a central valve port and peripheral mounting flange, and an annular corrugation in between. A groove between the first and second ridges serves as a flexure zone during operation of the valve member and thus provides the seating pressure between the inner ridge or valve seat and the valve element. The outer annular ridge has a diameter less than said valve element to limit the seating motion of the valve element, preventing non-elastic deformation of the seat member.
The Ross operation: a 12-year experience.
Elkins, R C
1999-09-01
The Ross operation, originally introduced as a scalloped subcoronary implant with an 80% survival and 85% freedom from reoperation, has recently been modified to a root replacement which is now the most utilized implant technique. The mid and late results of this operative technique and comparison of intra-aortic implants and root replacement in a single institution are reported. The records of 328 patients who had a Ross operation at the University of Oklahoma (August 1986 to July 1998) were reviewed to assess operative technique and patient-related factors on survival, autograft valve function, homograft valve function, valve-related complications, and need for reoperation. Operative survival was 95.4% with an actuarial survival of 89% +/- 5% at 8 years. Freedom from replacement of the pulmonary autograft was 94% +/- 3% at 8 years, freedom from reoperation on the pulmonary homograft was 90% +/- 4% at 8 years, and freedom from autograft valve reoperation or dysfunction (3+ autograft valve insufficiency) was 83% +/- 6% at 9 years. The incidence of autograft valve reoperation and late autograft valve dysfunction was decreased by root replacement. Annulus reduction and fixation improved early results in patients with aortic insufficiency and annulus dilatation. Early results have been excellent, as the development of late autograft valve dysfunction or dilatation has been rare. The excellent hemodynamic results with a limited incidence of reoperation and replacement of the autograft valve justify its continued use.
Joule-Thomson valves for long term service in space cryocoolers
NASA Technical Reports Server (NTRS)
Lester, J. M.; Benedict, B.
1985-01-01
Joule-Thomson valves for small cryocoolers have throttling passages on the order of 0.1 millimeter in diameter. Consequently, they can become plugged easily and stop the operation of the cooler. Plugging can be caused by solid particles, liquids or gases. Plugging is usually caused by the freezing of contaminant gases from the process stream. In small open loop coolers and in closed loop coolers where periodic maintenance is allowed, the problem is overcome by using careful assembly techniques, pure process gases, warm filters and cold adsorbers. A more thorough approach is required for closed loop cryocoolers which must operate unattended for long periods. This paper presents the results of an effort to solve this problem. The causes of plugging are examined, and various ways to eliminate plugging are discussed. Finally, the development of a J-T defroster is explained. It is concluded that a combination of preventive measures and a defroster will reduce the chance of cooler failure by plugging to such a degree that J-T coolers can be used for long term space missions.
Casada, D.A.
1996-01-16
A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization. 14 figs.
Casada, Donald A.
1996-01-01
A method and apparatus are provided for monitoring a motor operated valve during the brief period when the valve seats and the torque switch trips to deenergize the valve motor. The method uses voltage measurements on the load side of a deenergizing switch that opens to deenergize the motor to determine, among other things, final motor rotational speed and the decelerating torque at motor deenergization.
Diagnostic for two-mode variable valve activation device
Fedewa, Andrew M
2014-01-07
A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.
NASA Technical Reports Server (NTRS)
Helms, C. R.; Smyly, H. M. (Inventor)
1981-01-01
A pump/valve unit for controlling the inflation and deflation of a urethral collar in a prosthetic urinary sphincter device is described. A compressible bulb pump defining a reservoir was integrated with a valve unit for implantation. The valve unit includes a movable valve member operable by depression of a flexible portion of the valve unit housing for controlling fluid flow between the reservoir and collar; and a pressure sensing means which operates the valve member to relieve an excess pressure in the collar should too much pressure be applied by the patient.
A Parylene MEMS Electrothermal Valve
Li, Po-Ying; Givrad, Tina K.; Holschneider, Daniel P.; Maarek, Jean-Michel I.; Meng, Ellis
2011-01-01
The first microelectromechanical-system normally closed electrothermal valve constructed using Parylene C is described, which enables both low power (in milliwatts) and rapid operation (in milliseconds). This low-power valve is well suited for applications in wirelessly controlled implantable drug-delivery systems. The simple design was analyzed using both theory and modeling and then characterized in benchtop experiments. Operation in air (constant current) and water (current ramping) was demonstrated. Valve-opening powers of 22 mW in air and 33 mW in water were obtained. Following integration of the valve with catheters, our valve was applied in a wirelessly operated microbolus infusion pump, and the in vivo functionality for the appropriateness of use of this pump for future brain mapping applications in small animals was demonstrated. PMID:21350679
78 FR 70198 - Airworthiness Directives; Rolls-Royce Deutschland Ltd & Co KG Turbofan Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-25
.... This AD requires a one-time inspection of the high-pressure (HP) air bleed valve operating mechanism... discovered that the High Pressure (HP) air bleed valve operating mechanism is exposed to excessive... excessive deterioration of the high- pressure (HP) air bleed valve operating mechanism which is influencing...
DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.
2006-08-29
Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.
When a Heart Murmur Signals Valve Disease
... in adults may be related to: Valve calcification Endocarditis Rheumatic fever In children, abnormal heart murmurs may ... Problem: Pulmonary Valve Regurgitation Heart Valves and Infective Endocarditis Left Ventricular Hypertrophy • Risks, Signs and Symptoms • Accurate ...
Engine including hydraulically actuated valvetrain and method of valve overlap control
Cowgill, Joel [White Lake, MI
2012-05-08
An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.
Application of fuzzy adaptive control to a MIMO nonlinear time-delay pump-valve system.
Lai, Zhounian; Wu, Peng; Wu, Dazhuan
2015-07-01
In this paper, a control strategy to balance the reliability against efficiency is introduced to overcome the common off-design operation problem in pump-valve systems. The pump-valve system is a nonlinear multi-input-multi-output (MIMO) system with time delays which cannot be accurately measured but can be approximately modeled using Bernoulli Principle. A fuzzy adaptive controller is applied to approximate system parameters and achieve the control of delay-free model since the system model is inaccurate and the direct feedback linearization method cannot be applied. An extended Smith predictor is introduced to compensate time delays of the system using the inaccurate system model. The experiment is carried out to verify the effectiveness of the control strategy whose results show that the control performance is well achieved. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.
Prognostics for Ground Support Systems: Case Study on Pneumatic Valves
NASA Technical Reports Server (NTRS)
Daigle, Matthew; Goebel, Kai
2011-01-01
Prognostics technologies determine the health (or damage) state of a component or sub-system, and make end of life (EOL) and remaining useful life (RUL) predictions. Such information enables system operators to make informed maintenance decisions and streamline operational and mission-level activities. We develop a model-based prognostics methodology for pneumatic valves used in ground support equipment for cryogenic propellant loading operations. These valves are used to control the flow of propellant, so failures may have a significant impact on launch availability. Therefore, correctly predicting when valves will fail enables timely maintenance that avoids launch delays and aborts. The approach utilizes mathematical models describing the underlying physics of valve degradation, and, employing the particle filtering algorithm for joint state-parameter estimation, determines the health state of the valve and the rate of damage progression, from which EOL and RUL predictions are made. We develop a prototype user interface for valve prognostics, and demonstrate the prognostics approach using historical pneumatic valve data from the Space Shuttle refueling system.
A normally-closed piezoelectric micro-valve with flexible stopper
NASA Astrophysics Data System (ADS)
Chen, Song; Lu, Song; Liu, Yong; Wang, Jiantao; Tian, Xiaochao; Liu, Guojun; Yang, Zhigang
2016-04-01
In the field of controlled drug delivery system, there are still many problems on those reported micro-valves, such as the small opening height, unsatisfactory particle tolerance and high cost. To solve the above problems, a novel normally-closed piezoelectric micro-valve is presented in this paper. The micro-valve was driven by circular unimorph piezoelectric vibrator and natural rubber membrane with high elasticity was used as the valve stopper. The small axial displacement of piezoelectric vibrator can be converted into a large stroke of valve stopper based on hydraulic amplification mechanism. The experiment indicates that maximum hydraulic amplification ratio is up to 14, and the cut-off pressure of the micro-valve is 39kPa in the case of no working voltage. The presented micro valve has a large flow control range (ranging from 0 to 8.75mL/min).
Monovalve with integrated fuel injector and port control valve, and engine using same
Milam, David M.
2002-01-01
Each cylinder of an internal combustion engine includes a combined gas exchange valve and fuel injector with a port control valve. The port control valve operates to open either an intake passage or an exhaust passage. The operation of the combined device is controlled by a pair of electrical actuators. The device is hydraulically actuated.
Numerical Simulation of Flow in Fluidic Valves in Rotating Detonation Engines
NASA Astrophysics Data System (ADS)
Gopalakrishnan, Nandini
Rotating detonation engines (RDE) have received considerable research attention in recent times for use in propulsion systems. The cycle frequency of operation of an RDE can be as high as 10,000 Hz. Conventional mechanical valves cannot operate at such high frequencies, leading to the need for propellant injectors or valves with no moving parts. A fluidic valve is such a valve and is the focus of this study. The valve consists of an orifice connected to a constant area plenum cavity which operates at constant pressure. The fluidic valve supplies propellants to the detonation tube through the orifice. Hydrogen - oxygen detonation is studied in a tube with fluidic valves. A detailed 19-step chemical reaction mechanism has been used to model detonation and the flow simulated in ANSYS Fluent. This research aims to determine the location of contact surface in the cavity and the time taken for the contact surface to leave the valve after a shock wave has passed through it. This will help us understand if the steady-state flow in the cavity is comprised of detonation products or fresh propellants.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-14
... certain motor operated valve actuators for the fuel tanks are installed, and related investigative and... additional inspections to determine if certain motor operated valve actuators for the fuel tanks are... requires an inspection to determine if certain motor operated valve (MOV) actuators for the fuel tanks are...
MRI safety of a programmable shunt assistant at 3 and 7 Tesla.
Mirzayan, M Javad; Klinge, Petra M; Samii, Madjid; Goetz, Friedrich; Krauss, Joachim K
2012-06-01
Several new shunt technologies have been developed to optimize hydrocephalus treatment within the past few years. Overdrainage, however, still remains an unresolved problem. One new technology which may reduce the frequency of this complication is the use of a programmable shunt assistant (proSA). Inactive in a horizontal position, it impedes CSF flow in a vertical position according to a prescribed pressure level ranging from 0 to 40 cm H(2)O. We exposed the proSA valve in an ex vivo protocol to MR systems operating at 3 and 7 Tesla to investigate its MRI safety. Following 3 Tesla exposure, no changes in valve settings were noted. Adjustment to any pressure level was possible thereafter. The mean deflection angle was 23 ± 3°. After exposure to 7 Tesla, however, there were unintended pressure changes, and the mechanism for further adjustment of the valves even disintegrated. According to the results of this study, proSA is safe with heteropolar vertical magnet alignment at 3 Tesla. Following 7 Tesla exposure, the valves lost their functional capability.
Monitoring circuit accurately measures movement of solenoid valve
NASA Technical Reports Server (NTRS)
Gillett, J. D.
1966-01-01
Solenoid operated valve in a control system powered by direct current issued to accurately measure the valve travel. This system is currently in operation with a 28-vdc power system used for control of fluids in liquid rocket motor test facilities.
Siregar, Sabrina; de Heer, Frederiek; Groenwold, Rolf H H; Versteegh, Michel I M; Bekkers, Jos A; Brinkman, Emile S; Bots, Michiel L; van der Graaf, Yolanda; van Herwerden, Lex A
2014-09-01
The aim was to describe procedural volumes, patient risk profile and outcomes of heart valve surgery in the past 16 years in Netherlands. The Dutch National Database for Cardio-Thoracic Surgery includes approximately 200 000 cardiac operations performed between 1995 and 2010. Information on all valve surgeries (56 397 operations) was extracted. We determined trends for changes in procedural volume, demographics, risk profile and in-hospital mortality of valve operations. Because of incomplete data in the first years of registration, the total number of operations in those years was estimated using Poisson regression. For a subset from 2007 to 2010, follow-up data were available. Survival status was obtained through linkage with the national Cause of Death Registry, and survival analysis was performed using Kaplan-Meier method. Information on discharge and readmissions was obtained from the National Hospital Discharge Registry. The annual volume of heart valve operations increased by more than 100% from an estimated 2431 in 1995 to 5906 in 2010. Adjusted for population size in Netherlands, the number of operations per 100 000 adults increased from 20 in 1995 to 43 in 2010. In 2010, frequently performed valve surgery included the following: 34.6% isolated aortic valve (AoV) replacement, 21.8% AoV replacement and coronary artery bypass grafting (CABG), 14.6% isolated mitral valve surgery (repair or replacement) and 9.1% mitral valve and CABG. In AoV surgery, an increasing use of bioprostheses in all age categories is observed. In mitral valve surgery, 75.4% was performed by repair rather than replacement in 2010. In-hospital mortality for all valve surgery decreased significantly from 4.6% in 2007 to 3.6% in 2010, whereas the mean logistic EuroSCORE remained stable (median 5.8, P = 1.000). Thirty-day mortality after all valve surgery was 3.9% and 120-day mortality was 6.5%. At 1 year, survival after all valve surgery was 91.6% and a reoperation had been performed in 1.6%. The median postoperative length of stay was 7 days (interquartile range (IQR) 5-11) in the primary hospital and 11 days (IQR 8-16), including subsequent stay, in the secondary hospital. The results of this study provide a comprehensive overview of valve surgery trends and outcomes in Netherlands. The number of heart valve operations performed in Netherlands has increased since 1995. The significant decrease in mortality and unchanged EuroSCORE between 2007 and 2010 might reflect a general improvement of the safety of valve surgery. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Microfluidic Valves Made From Polymerized Polyethylene Glycol Diacrylate
Rogers, Chad I.; Oxborrow, Joseph B.; Anderson, Ryan R.; Tsai, Long-Fang; Nordin, Gregory P.; Woolley, Adam T.
2013-01-01
Pneumatically actuated, non-elastomeric membrane valves fabricated from polymerized polyethylene glycol diacrylate (poly-PEGDA) have been characterized for temporal response, valve closure, and long-term durability. A ~100 ms valve opening time and a ~20 ms closure time offer valve operation as fast as 8 Hz with potential for further improvement. Comparison of circular and rectangular valve geometries indicates that the surface area for membrane interaction in the valve region is important for valve performance. After initial fabrication, the fluid pressure required to open a closed circular valve is ~50 kPa higher than the control pressure holding the valve closed. However, after ~1000 actuations to reconfigure polymer chains and increase elasticity in the membrane, the fluid pressure required to open a valve becomes the same as the control pressure holding the valve closed. After these initial conditioning actuations, poly-PEGDA valves show considerable robustness with no change in effective operation after 115,000 actuations. Such valves constructed from non-adsorptive poly-PEGDA could also find use as pumps, for application in small volume assays interfaced with biosensors or impedance detection, for example. PMID:24357897
Ross procedure for ascending aortic replacement.
Elkins, R C; Lane, M M; McCue, C
1999-06-01
Patients with aortic valve disease and aneurysm or dilatation of the ascending aorta require both aortic valve replacement and treatment of their ascending aortic disease. In children and young adults, the Ross operation is preferred when the aortic valve requires replacement, but the efficacy of extending this operation to include replacement of the ascending aorta or reduction of the dilated aorta has not been tested. We reviewed the medical records of 18 (5.9%) patients with aortic valve disease and an ascending aortic aneurysm and 26 (8.5%) patients with dilation of the ascending aorta, subgroups of 307 patients who had a Ross operation between August 1986 and February 1998. We examined operative and midterm results, including recent echocardiographic assessment of autograft valve function and ability of the autograft root and ascending aortic repair or replacement to maintain normal structural integrity. There was one operative death (2%) related to a perioperative stroke. Forty-two of 43 survivors have normal autograft valve function, with trace to mild autograft valve insufficiency, and one patient has moderate insufficiency at the most recent echocardiographic evaluation. None of the patients has dilatation of the autograft root or of the replaced or reduced ascending aorta. Early results with extension of the Ross operation to include replacement of an ascending aortic aneurysm or vertical aortoplasty for reduction of a dilated ascending aorta are excellent, with autograft valve function equal to that seen in similar patients without ascending aortic disease.
Solenoid Valve With Self-Compensation
NASA Technical Reports Server (NTRS)
Woeller, Fritz H.; Matsumoto, Yutaka
1987-01-01
New solenoid-operated miniature shutoff valve provides self-compensation of differential pressure forces that cause jamming or insufficient valve closure as in single-seal valves. Dual-seal valve is bidirectional. Valve simultaneously seals both inlet and outlet tubes by pressing single disk of silicone rubber against ends of both.
Locking apparatus for gate valves
Fabyan, J.; Williams, C.W.
A locking apparatus for fluid operated valves having a piston connected to the valve actuator which moves in response to applied pressure within a cylinder housing having a cylinder head, a catch block is secured to the piston, and the cylinder head incorporates a catch pin. Pressure applied to the cylinder to open the valve moves the piston adjacent to the cylinder head where the catch pin automatically engages the catch block preventing further movement of the piston or premature closure of the valve. Application of pressure to the cylinder to close the valve, retracts the catch pin, allowing the valve to close. Included are one or more selector valves, for selecting pressure application to other apparatus depending on the gate valve position, open or closed, protecting such apparatus from damage due to premature closing caused by pressure loss or operational error.
Reul, Ross M.; Ramchandani, Mahesh K.; Reardon, Michael J.
2017-01-01
Surgical aortic valve replacement is the gold standard procedure to treat patients with severe, symptomatic aortic valve stenosis or insufficiency. Bioprosthetic valves are used for surgical aortic valve replacement with a much greater prevalence than mechanical valves. However, bioprosthetic valves may fail over time because of structural valve deterioration; this often requires intervention due to severe bioprosthetic valve stenosis or regurgitation or a combination of both. In select patients, transcatheter aortic valve replacement is an alternative to surgical aortic valve replacement. Transcatheter valve-in-valve (ViV) replacement is performed by implanting a transcatheter heart valve within a failing bioprosthetic valve. The transcatheter ViV operation is a less invasive procedure compared with reoperative surgical aortic valve replacement, but it has been associated with specific complications and requires extensive preoperative work-up and planning by the heart team. Data from experimental studies and analyses of results from clinical procedures have led to strategies to improve outcomes of these procedures. The type, size, and implant position of the transcatheter valve can be optimized for individual patients with knowledge of detailed dimensions of the surgical valve and radiographic and echocardiographic measurements of the patient's anatomy. Understanding the complexities of the ViV procedure can lead surgeons to make choices during the original surgical valve implantation that can make a future ViV operation more technically feasible years before it is required. PMID:29743998
Should patients with Björk-Shiley valves undergo prophylactic replacement?
Birkmeyer, J D; Marrin, C A; O'Connor, G T
1992-08-29
About 85,000 patients have undergone replacement of diseased heart valves with prosthetic Björk-Shiley convexo-concave (CC) valves. These valves are prone to fracture of the outlet strut, which leads to acute valve failure that is usually fatal. Should patients with these valves undergo prophylactic replacement to avoid fracture? The incidence of strut fracture varies between 0% and 1.5% per year, depending on valve opening angle (60 degrees or 70 degrees), diameter (less than 29 mm or greater than or equal to 29 mm), and location (aortic or mitral). Other factors include the patient's life expectancy and the expected morbidity and mortality associated with reoperation. We have used decision analysis to identify the patients most likely to benefit from prophylactic reoperation. The incidence of outlet strut fracture was estimated from the data of three large studies on CC valves, and stratified by opening angle, diameter, and location. A Markov decision analysis model was used to estimate life expectancy for patients undergoing prophylactic valve replacement and for those not undergoing reoperation. Prophylactic valve replacement does not benefit patients with CC valves that have low strut fracture risks (60 degrees aortic valves and less than 29 mm, 60 degrees mitral valves). For most patients with CC valves that have high strut fracture risks (greater than or equal to 29 mm, 70 degrees CC), prophylactic valve replacement increases life expectancy. However, elderly patients with such valves benefit from prophylactic reoperation only if the risk of operative mortality is low. Patient age and operative risk are most important in recommendations for patients with CC valves that have intermediate strut fracture risks (less than 29 mm, 70 degrees valves and greater than or equal to 29 mm, 60 degrees mitral valves). For all patients and their doctors facing the difficult decision on whether to replace CC valves, individual estimates of operative mortality risk that take account of both patient-specific and institution-specific factors are essential.
Fabrication and test of digital output interface devices for gas turbine electronic controls
NASA Technical Reports Server (NTRS)
Newirth, D. M.; Koenig, E. W.
1978-01-01
A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.
Trans-catheter aortic valve implantation after previous aortic homograft surgery.
Drews, Thorsten; Pasic, Miralem; Buz, Semih; Unbehaun, Axel
2011-12-01
In patients with previous heart surgery, the operative risk is elevated during conventional aortic valve re-operations. Trans-catheter aortic valve implantation is a new method for the treatment of high-risk patients. Nevertheless, this new procedure carries potential risks in patients with previous homograft implantation in aortic position. Between April 2008 and February 2011, 345 consecutive patients (mean EuroSCORE (European System for Cardiac Operative Risk Evaluation): 38 ± 20%; mean Society of Thoracic Surgeons (STS) Mortality Score: 19 ± 16%; mean age: 80 ± 8 years; 111 men and 234 women) underwent trans-apical aortic valve implantation. In three patients, previous aortic homograft implantation had been performed. Homograft degeneration causing combined valve stenosis and incompetence made re-operation necessary. In all three patients, the aortic valve could be implanted using the trans-apical approach, and the procedure was successful. In two patients, there was slight paravalvular leakage of the aortic prosthesis and the other patient had slight central leakage. Neither ostium obstruction nor mitral valve damage was observed. Trans-catheter valve implantation can be performed successfully after previous homograft implantation. Particular care should be taken to achieve optimal valve positioning, not to obstruct the ostium of the coronary vessels due to the changed anatomic situation and not to cause annulus rupture. Copyright © 2011 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Shyu, K G; Cheng, J J; Chen, J J; Lin, J L; Lin, F Y; Tseng, Y Z; Kuan, P; Lien, W P
1994-08-01
We prospectively studied the recovery of atrial function after atrial compartment operation and mitral valve surgery in patients with chronic atrial fibrillation caused by mitral valve disease. Chronic atrial fibrillation is the most common arrhythmia in mitral valve disease. This arrhythmia is associated with excessive morbidity and mortality. Mitral valve surgery alone rarely eliminates it. Twenty-two patients underwent mitral valve surgery and a new surgical method, atrial compartment operation. Doppler echocardiography was performed in all patients before operation and at 1 week and 2 and 6 months after operation in the successful cardioversion group. Peak early diastolic (E) and atrial (A) filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves were measured. Sinus rhythm was restored immediately after operation in 91% of patients and was maintained for > 1 week in 15 (68%) of 22 patients and > 6 months in 14 (64%) of 22. Eleven of 15 patients had left atrial paralysis (A/E integral ratio 0) at 1 week and 6 of 14 patients at 2 months. Nine of 15 patients had right atrial paralysis (A/E integral ratio 0) at 1 week and 1 of 14 patients at 2 months. Both left and right atrial contractile function (presence of an A wave on Doppler findings) was detected at 6 months in 14 patients. Mean (+/- SD) peak atrial filling velocity of the mitral valve was 15 +/- 26 cm/s at 1 week, 38 +/- 39 cm/s at 2 months and 93 +/- 32 cm/s at 6 months (p < 0.001). Mean peak atrial filling velocity of the tricuspid valve was 14 +/- 19 cm/s at 1 week, 33 +/- 19 cm/s at 2 months and 50 +/- 19 cm/s at 6 months (p < 0.001). Peak early diastolic and atrial filling velocities, peak A/E velocity ratio and A/E integral ratio of the mitral and tricuspid valves increased significantly from 1 week to 6 months. Chronic atrial fibrillation in mitral valve disease can often be eliminated by atrial compartment operation. No surgical mortality or significant complications were encountered. Both left and right atrial function, as manifested by Doppler findings, recover after compartment operation and improve over time. The mechanical function of the right atrium recovers earlier than that of the left.
High-temperature, high-pressure oxygen metering valve
NASA Technical Reports Server (NTRS)
Christianson, Rollin C. (Inventor); Lycou, Peter P. (Inventor); Daniel, James A. (Inventor)
1993-01-01
A control valve includes a body defining a central cavity arranged between a fluid inlet and outwardly-diverging first and second fluid outlets respectively disposed in a common transverse plane. A valve member is arranged in the cavity for rotation between first and second operating positions where a transverse fluid passage through the valve member alternatively communicates the fluid inlet with one or the other of the fluid outlets. To minimize fluid turbulence when the valve member is rotated to an alternate operating position, the fluid passage has a convergent entrance for maintaining the passage in permanent communication with the fluid inlet as well as an oblong exit opening with spaced side walls for enabling the exit opening to temporarily span the first and second fluid outlets as the valve member is turned between its respective operating positions.
NASA Astrophysics Data System (ADS)
Zakirnichnaya, M. M.; Kulsharipov, I. M.
2017-10-01
Wedge gate valves are widely used at the fuel and energy complex enterprises. The pipeline valves manufacturers indicate the safe operation resource according to the current regulatory and technical documentation. In this case, the resource value of the valve body strength calculation results is taken into consideration as the main structural part. However, it was determined that the wedge gate valves fail before the assigned resource due to the occurrence of conditions under which the wedge breaks in the hooks and, accordingly, the sealing integrity is not ensured. In this regard, it became necessary to assess the conditions under which the resource should be assigned not only to the valve body, but also to take into account the wedge durability. For this purpose, wedge resource calculations were made using the example of ZKL2 250-25 and ZKL2 300-25 valves using the ABAQUS software package FE-SAFE module under the technological parameters influence on the basis of their stressstrain state calculation results. Operating conditions, under which the wedge resource value is lower than the one set by the manufacturer, were determined. A technique for limiting the operating parameters for ensuring the wedge durability during the wedge gate valve assigned resource is proposed.
NASA Astrophysics Data System (ADS)
Hill, Marc; Rizzello, Gianluca; Seelecke, Stefan
2017-08-01
Due to their many features including lightweight and low energy consumption, dielectric elastomer (DE) membrane actuators are of interest for a number of industrial applications, such as pumping systems or valve control units. In particular, the use of DEs in valve control units offers advantages over traditional solenoid valves, including lower power requirements and relative simplicity in achieving proportional control. Additionally, DEs generate low thermal dissipation and are capable of virtually silent operation. The contribution of this work is the development of a new valve system based on a circular DE membrane pre-loaded with a linear spring. The valve is designed for pressurized air and operates by actuating a lever mechanism that opens and closes an outlet port. After presenting the operating principle and system design, several experiments are presented to compare actuator force, stroke, and dissipated energy for several pressure differentials and associated volume flows. It is observed that the DE-driven valve achieves a performance similar to a solenoid-based valve, while requiring a significantly lower amount of input energy. In addition, it is shown that DE-membrane valves can be controlled proportionally by simply adjusting the actuator voltage.
Valve for controlling solids flow
Feldman, David K.
1980-01-01
A fluidized solids control valve is disclosed that is particularly well adapted for use with a flow of coal or char that includes both large particles and fines. The particles may or may not be fluidized at various times during the operation. The valve includes a tubular body that terminates in a valve seat covered by a normally closed closure plate. The valve body at the seat and the closure plate is provided with aligned longitudinal slots that receive a pivotally supported key plate. The key plate is positionable by an operator in inserted, intermediate and retracted positions respecting the longitudinal slot in the valve body. The key plate normally closes the slot within the closure plate but is shaped and aligned obliquely to the longitudinal slot within the valve body to provide progressively increasing slot openings between the inserted and retracted positions. Transfer members are provided between the operator, key plate and closure plate to move the closure plate into an open position only when the key plate is retracted from the longitudinal slot within the valve body.
The Effect of Valve Cooling upon Maximum Permissible Engine Output as Limited by Knock
NASA Technical Reports Server (NTRS)
Munger, Maurice; Wilsted, H D; Mulcahy, B A
1942-01-01
A Wright GR-1820-G200 cylinder was tested over a wide range of fuel-air ratios at maximum permissible power output as limited by knock with three different degrees of valve cooling. The valves used were stock valves (solid inlet valve and hollow sodium-cooled exhaust valve), hollow valves with no coolant, and hollow valves with flowing water as a coolant. Curves showing the variation in maximum permissible values of inlet-air pressure, indicated mean effective pressure, cylinder charge, and indicated specific fuel consumption with change in fuel-air ratio and valve cooling are shown. The use of valves cooled by a stream of water passing through their hollow interiors permitted indicated mean effective pressures 10 percent higher than the mean effective pressures permissible with stock valves when the engine was operated with fuel-air ratios from 0.055 to 0.065. Operation of the engine with lean mixtures with uncooled hollow valves resulted in power output below the output obtained with the stock valves. The data show an increase in maximum permissible indicated mean effective pressure due to cooling the valves, which averages only 2.1 percent with fuel-air ratios from 0.075 to 0.105.
Understanding Heart Valve Problems and Causes
... and conditions that can cause valve problems: Infective endocarditis Injury Rheumatic fever These conditions can cause one ... Surgery? Recovery Milestones Checklist | Spanish What Is Infective Endocarditis? | Spanish Interactive Treatment Guide Infographic: What Everyone Should ...
Simulation of a Hydraulic Pump Control Valve
NASA Technical Reports Server (NTRS)
Molen, G. Vander; Akers, A.
1987-01-01
This paper describes the mode of operation of a control valve assembly that is used with a hydraulic pump. The operating system of the valve is modelled in a simplified form, and an analogy for hydraulic resonance of the pressure sensing system is presented. For the control valve investigated, air entrainment, length and diameter of the resonator neck, and valve mass produced the greatest shift in resonant frequency. Experimental work was conducted on the hydraulic system so that the resonance levels and frequencies could be measured and the accuracy of the theory verified. The results obtained make it possible to evaluate what changes to any of the variables considered would be most effective in driving the second harmonic frequency above the operating range.
NASA Technical Reports Server (NTRS)
Wichmann, Horst; Marquardt, Kaiser; Goforth, Alyssa
1993-01-01
Design of a direct-acting valve (DAV) for a primary thruster which is fully interchangeable with a thruster equipped with pilot-operated valves is described. The DAV is based on a bellows to isolate propellants form the actuator for maximum resistance to iron nitrate and other contamination and to select optimum materials for the actuator. It provides improved seal performance under all operating conditions and insensitivity to pressure transients. As compared with the existing pilot-operated valve, the DAV design is much simpler, consists of fewer parts, and will be lower in cost.
Hydraulic flow visualization method and apparatus
Karidis, Peter G.
1984-01-01
An apparatus and method for visualizing liquid flow. Pulses of gas bubbles are introduced into a liquid flow stream and a strobe light is operated at a frequency related to the frequency of the gas pulses to shine on the bubbles as they pass through the liquid stream. The gas pulses pass through a probe body having a valve element, and a reciprocating valve stem passes through the probe body to operate the valve element. A stem actuating device comprises a slidable reciprocating member, operated by a crank arm. The actuated member is adjustable to adjust the amount of the valve opening during each pulse.
Shafer, Scott F.
2002-01-01
The present invention relates to hydraulic systems including hydraulically actuated fuel injectors that have a pilot operated spool valve assembly. One class of hydraulically actuated fuel injectors includes a solenoid driven pilot valve that controls the initiation of the injection event. However, during cold start conditions, hydraulic fluid, typically engine lubricating oil, is particularly viscous and is often difficult to displace through the relatively small drain path that is defined past the pilot valve member. Because the spool valve typically responds slower than expected during cold start due to the difficulty in displacing the relatively viscous oil, accurate start of injection timing can be difficult to achieve. There also exists a greater difficulty in reaching the higher end of the cold operating speed range. Therefore, the present invention utilizes a fluid evacuation valve to aid in displacement of the relatively viscous oil during cold start conditions.
Wang, Tiancai; He, Xing; Huang, Tingwen; Li, Chuandong; Zhang, Wei
2017-09-01
The economic emission dispatch (EED) problem aims to control generation cost and reduce the impact of waste gas on the environment. It has multiple constraints and nonconvex objectives. To solve it, the collective neurodynamic optimization (CNO) method, which combines heuristic approach and projection neural network (PNN), is attempted to optimize scheduling of an electrical microgrid with ten thermal generators and minimize the plus of generation and emission cost. As the objective function has non-derivative points considering valve point effect (VPE), differential inclusion approach is employed in the PNN model introduced to deal with them. Under certain conditions, the local optimality and convergence of the dynamic model for the optimization problem is analyzed. The capability of the algorithm is verified in a complicated situation, where transmission loss and prohibited operating zones are considered. In addition, the dynamic variation of load power at demand side is considered and the optimal scheduling of generators within 24 h is described. Copyright © 2017 Elsevier Ltd. All rights reserved.
Problem: Heart Valve Regurgitation
... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...
Problem: Mitral Valve Regurgitation
... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...
Tracking control of a spool displacement in a direct piezoactuator-driven servo valve system
NASA Astrophysics Data System (ADS)
Han, Chulhee; Hwang, Yong-Hoon; Choi, Seung-Bok
2017-03-01
This paper presents tracking control performances of a piezostack direct drive valve (PDDV) operated at various temperatures. As afirst step, a spool valve and valve system are designed operated by the piezoactuator. After briefly describing about operating principle, an experimental apparatus to investigate the effect of temperaturs on the performances is set up. Subsequently, the PDDV is installed in a large-size heat chamber equipped with electric circuits and sensors. A classical proportional-integral-derivative (PID) controller is designed and applied to control the spool displacement. In addition, a fuzzt algorithm is integrated with the PID controller to enhace performance of the proposed valve system. The tracking performance of a spool displacement is tested by increasing the teperature and exciting frequency up to 150°C and 200 Hz, respectively. It is shown that the tracking performance heavily depends on both the operating temperature and the excitation frequency.
Transcatheter Aortic Valve Replacement for Native Aortic Valve Regurgitation
Spina, Roberto; Anthony, Chris; Muller, David WM
2015-01-01
Transcatheter aortic valve replacement with either the balloon-expandable Edwards SAPIEN XT valve, or the self-expandable CoreValve prosthesis has become the established therapeutic modality for severe aortic valve stenosis in patients who are not deemed suitable for surgical intervention due to excessively high operative risk. Native aortic valve regurgitation, defined as primary aortic incompetence not associated with aortic stenosis or failed valve replacement, on the other hand, is still considered a relative contraindication for transcatheter aortic valve therapies, because of the absence of annular or leaflet calcification required for secure anchoring of the transcatheter heart valve. In addition, severe aortic regurgitation often coexists with aortic root or ascending aorta dilatation, the treatment of which mandates operative intervention. For these reasons, transcatheter aortic valve replacement has been only sporadically used to treat pure aortic incompetence, typically on a compassionate basis and in surgically inoperable patients. More recently, however, transcatheter aortic valve replacement for native aortic valve regurgitation has been trialled with newer-generation heart valves, with encouraging results, and new ancillary devices have emerged that are designed to stabilize the annulus–root complex. In this paper we review the clinical context, technical characteristics and outcomes associated with transcatheter treatment of native aortic valve regurgitation. PMID:29588674
Aortic annulus sizing using watershed transform and morphological approach for CT images
NASA Astrophysics Data System (ADS)
Mohammad, Norhasmira; Omar, Zaid; Sahrim, Mus'ab
2018-02-01
Aortic valve disease occurs due to calcification deposits on the area of leaflets within the human heart. It is progressive over time where it can affect the mechanism of the heart valve. To avoid the risk of surgery for vulnerable patients especially senior citizens, a new method has been introduced: Transcatheter Aortic Valve Implantation (TAVI), which places a synthetic catheter within the patient's valve. This entails a procedure of aortic annulus sizing, which requires manual measurement of the scanned images acquired from Computed Tomographic (CT) by experts. The step requires intensive efforts, though human error may still eventually lead to false measurement. In this research, image processing techniques are implemented onto cardiac CT images to achieve an automated and accurate measurement of the heart annulus. The image is first put through pre-processing for noise filtration and image enhancement. Then, a marker image is computed using the combination of opening and closing operations where the foreground image is marked as a feature while the background image is set to zero. Marker image is used to control the watershed transformation and also to prevent oversegmentation. This transformation has the advantage of fast computational and oversegmentation problems, which usually appear with the watershed transform can be solved with the introduction of marker image. Finally, the measurement of aortic annulus from the image data is obtained through morphological operations. Results affirm the approach's ability to achieve accurate annulus measurements compared to conventional techniques.
NASA Technical Reports Server (NTRS)
Waller, Jess M.; Roth, Tim E.; Saulsberry, Regor L.; Haney, William A.; Kelly, Terence S; Forsyth, Bradley S.
2004-01-01
Extrusion of a polytetrafluoroethylene (PTFE) pilot seal located in the Space Shuttle Orbiter Primary Reaction Control Subsystem (PRCS) thruster fuel valve has been implicated in 68 ground and on-orbit fuel valve failures. A rash of six extrusion-related in-flight anomalies over a six-mission span from December 2001 to October 2002 led to heightened activity at various NASA centers, and the formation of a multidisciplinary team to solve the problem. Empirical and theoretical approaches were used. For example, thermomechanical analysis (TMA) and exposure tests showed that some extrusion is produced by thermal cycling; however, a review of thruster service histories did not reveal a strong link between thermal cycling and extrusion. Calculations showed that the amount of observed extrusion often exceeded the amount allowed by thermally-induced stress relief. Failure analysis of failed hardware also revealed the presence of fuel-oxidizer reaction product (FORP) inside the fuel valve pilot seal cavity, and differential scanning calorimetry (DSC) showed that the FORP was intimately associated with the pilot seal material. Component-level exposure tests showed that FORP of similar composition could be produced by adjacent oxidizer valve leakage in the absence of thruster firing. Specific gravity data showed that extruded fuel valve pilot seals were less dense than new pilot seals or oxidizer valve pilot seals, indicating permanent modification of the PTFE occurred during service. It is concluded that some thermally-induced extrusion is unavoidable; however, oxidizer leakage-induced extrusion is mostly avoidable and can be mitigated. Several engineering level mitigation strategies are discussed.
NASA Technical Reports Server (NTRS)
Gelalles, A G; Rothrock, A M
1930-01-01
This research on the pressure variations in the injection system of the N.A.C.A. Spray Photography Equipment and on the effects of these variations on the motion of the timing valve stem was undertaken in connection with the study of fuel injection systems for high-speed oil engines. The methods of analysis of the pressure variations and the general equation for the motion of the spring-loaded stem for the timing valve are applicable to a spring-loaded automatic injection valve, and in general to all hydraulically operated valves. A sample calculation for a spring-loaded automatic injection valve is included.
Liquid rocket valve components
NASA Technical Reports Server (NTRS)
1973-01-01
A monograph on valves for use with liquid rocket propellant engines is presented. The configurations of the various types of valves are described and illustrated. Design criteria and recommended practices for the various valves are explained. Tables of data are included to show the chief features of valve components in use on operational vehicles.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.
Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., inside BOPs, and drill-string safety valves? 250.445 Section 250.445 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System...
Code of Federal Regulations, 2012 CFR
2012-07-01
..., inside BOPs, and drill-string safety valves? 250.445 Section 250.445 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System...
Code of Federal Regulations, 2013 CFR
2013-07-01
..., inside BOPs, and drill-string safety valves? 250.445 Section 250.445 Mineral Resources BUREAU OF SAFETY AND ENVIRONMENTAL ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System...
Joo, Hyung Joon; Hong, Soon Jun; Yu, Cheol Woong
2015-03-01
A 43-year-old man presented with severe aortic stenosis. Eight years previously, he had undergone primary surgical aortic valve replacement (AVR) for severe aortic regurgitation, but one year later developed cardiac arrest and complete atrioventricular block as a result of non-bacterial thrombotic endocarditis with severe valvular dehiscence. Following the diagnosis of prosthetic valve failure caused by Behçet's disease, the patient underwent a Bentall operation using 23 mm aortic homograft with permanent pacemaker implantation and coronary artery bypass grafting. Subsequently, he was stable with steroid administration and azathioprine for seven years after the second operation, but recently suffered from severe dyspnea and chest pain. Echocardiography revealed the development of severe aortic stenosis. A preprocedural evaluation demonstrated a porcelain aorta with severe calcification in the previous homograft valve on computed tomography, and critical stenosis at the ostium of the left circumflex artery on coronary angiography. After percutaneous coronary intervention for the ostium of the left circumflex artery, a transcatheter AVR was successfully performed using a 26 mm Edwards SAPIEN XT valve. The patient recovered without any complications after the procedure. This is the first report of a successful transcatheter aortic valve-in valve implantation for severe homograft aortic stenosis after a Bentall operation, using a homograft, in a patient with Behçet's disease.
Self-contained cryogenic gas sampling apparatus and method
McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.
1996-03-26
Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.
Red flag in the emergency department: fracture and primary failure of a prosthetic valve.
Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat
2005-07-01
This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.
Hydraulic High Pressure Valve Controller Using the In-Situ Pressure Difference
NASA Technical Reports Server (NTRS)
Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Hall, Jeffery L. (Inventor); Sherrit, Stewart (Inventor); Bao, Xiaoqi (Inventor)
2016-01-01
A hydraulic valve controller that uses an existing pressure differential as some or all of the power source for valve operation. In a high pressure environment, such as downhole in an oil or gas well, the pressure differential between the inside of a pipe and the outside of the pipe may be adequately large to drive a linear slide valve. The valve is operated hydraulically by a piston in a bore. When a higher pressure is applied to one end of the bore and a lower pressure to the other end, the piston moves in response to the pressure differential and drives a valve attached to it. If the pressure differential is too small to drive the piston at a sufficiently high speed, a pump is provided to generate a larger pressure differential to be applied. The apparatus is conveniently constructed using multiport valves, which can be rotary valves.
Self-contained cryogenic gas sampling apparatus and method
McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.
1996-01-01
Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.
[A case report of Ebstein's anomaly treated with Hetzer's procedure].
Sako, H; Hadama, T; Shigemitsu, O; Miyamoto, S; Anai, H; Wada, T; Iwata, E; Mori, Y; Soeda, T; Takakura, K
2001-02-01
A 27-year-old male who had been diagnosed with Ebstein's anomaly was admitted with uncontrollable congestive heart failure. The echocardiogram revealed severe tricuspid valve incompetence and the electrocardiogram showed atrial fibrillation. He underwent Hetzer's repair procedure for tricuspid valve incompetence and Minzioni's right atrial isolation technique to restore sinus rhythm. His congestive heart failure quickly disappeared and sinus rhythm was restored after operation. He was discharged 3 weeks postoperatively and remains well 22 months after his operation. Hetzer's technique for tricuspid valve repair in Ebstein's anomaly restructures the valve mechanism at the level of the true tricuspid anulus by using the most mobile leaflet for valve closure without plication of the atrialized chamber. We conclude that Hetzer's procedure is an effective operation for Ebstein's anomaly.
THERMALLY OPERATED VAPOR VALVE
Dorward, J.G. Jr.
1959-02-10
A valve is presented for use in a calutron to supply and control the vapor to be ionized. The invention provides a means readily operable from the exterior of the vacuum tank of the apparatuss without mechanical transmission of forces for the quick and accurate control of the ionizing arc by a corresponding control of gas flow theretos thereby producing an effective way of carefully regulating the operation of the calutron. The invention consists essentially of a tube member extending into the charge bottle of a calutron devices having a poppet type valve closing the lower end of the tube. An electrical heating means is provided in the valve stem to thermally vary the length of the stem to regulate the valve opening to control the flow of material from the charge bottle.
Contamination avoidance devices for poppettype shutoff valves
NASA Technical Reports Server (NTRS)
Endicott, D. L.
1973-01-01
The determination of the cycle life is reported of the scal closure of a typical poppet-type shutoff valve in an uncontaminated GH2 environment and then compared this component performance with simulated operation with GN2 and LN2 containing controlled amounts of AL2O3 contaminant particles. The original valve design was tested for contamination damage tolerance characteristics under full-flow and cyclic-operating conditions, redesigned to improve the damage tolerance to contaminants, and then retested. The redesigned valve was found to have acceptable tolerance characteristics under all full-flow conditions and cyclic operation with small (25-75 microns) particulate contamination. The tolerance characteristics of the valve under cyclic conditions with large (75-250 microns) particulate contamination was improved but was not found to be completely satisfactory.
NASA Technical Reports Server (NTRS)
Kothe, E. (Inventor)
1967-01-01
A helmet design is described which encapsules the head of the wearer, is capable of being pressurized and provides a means for gaining internal access for the purpose of eating. A mechanically actuated valve that combines the purging of carbon dioxide and feeding operations by a simple movement of a mechanical lever obviates problems that are attendant in the type of feed and purge ports previously incorporated in pressurized helmets.
Mariner Mars 1971 attitude control subsystem flight performance
NASA Technical Reports Server (NTRS)
Schumacher, L.
1973-01-01
The flight performance of the Mariner 71 attitude control subsystem is discussed. Each phase of the mission is delineated and the attitude control subsystem is evaluated within the observed operational environment. Performance anomalies are introduced and discussed within the context of general performance. Problems such as the sun sensor interface incompatibility, gas valve leaks, and scan platform dynamic coupling effects are given analytical considerations.
A versatile valving toolkit for automating fluidic operations in paper microfluidic devices.
Toley, Bhushan J; Wang, Jessica A; Gupta, Mayuri; Buser, Joshua R; Lafleur, Lisa K; Lutz, Barry R; Fu, Elain; Yager, Paul
2015-03-21
Failure to utilize valving and automation techniques has restricted the complexity of fluidic operations that can be performed in paper microfluidic devices. We developed a toolkit of paper microfluidic valves and methods for automatic valve actuation using movable paper strips and fluid-triggered expanding elements. To the best of our knowledge, this is the first functional demonstration of this valving strategy in paper microfluidics. After introduction of fluids on devices, valves can actuate automatically after a) a certain period of time, or b) the passage of a certain volume of fluid. Timing of valve actuation can be tuned with greater than 8.5% accuracy by changing lengths of timing wicks, and we present timed on-valves, off-valves, and diversion (channel-switching) valves. The actuators require ~30 μl fluid to actuate and the time required to switch from one state to another ranges from ~5 s for short to ~50 s for longer wicks. For volume-metered actuation, the size of a metering pad can be adjusted to tune actuation volume, and we present two methods - both methods can achieve greater than 9% accuracy. Finally, we demonstrate the use of these valves in a device that conducts a multi-step assay for the detection of the malaria protein PfHRP2. Although slightly more complex than devices that do not have moving parts, this valving and automation toolkit considerably expands the capabilities of paper microfluidic devices. Components of this toolkit can be used to conduct arbitrarily complex, multi-step fluidic operations on paper-based devices, as demonstrated in the malaria assay device.
A versatile valving toolkit for automating fluidic operations in paper microfluidic devices
Toley, Bhushan J.; Wang, Jessica A.; Gupta, Mayuri; Buser, Joshua R.; Lafleur, Lisa K.; Lutz, Barry R.; Fu, Elain; Yager, Paul
2015-01-01
Failure to utilize valving and automation techniques has restricted the complexity of fluidic operations that can be performed in paper microfluidic devices. We developed a toolkit of paper microfluidic valves and methods for automatic valve actuation using movable paper strips and fluid-triggered expanding elements. To the best of our knowledge, this is the first functional demonstration of this valving strategy in paper microfluidics. After introduction of fluids on devices, valves can actuate automatically a) after a certain period of time, or b) after the passage of a certain volume of fluid. Timing of valve actuation can be tuned with greater than 8.5% accuracy by changing lengths of timing wicks, and we present timed on-valves, off-valves, and diversion (channel-switching) valves. The actuators require ~30 μl fluid to actuate and the time required to switch from one state to another ranges from ~5 s for short to ~50s for longer wicks. For volume-metered actuation, the size of a metering pad can be adjusted to tune actuation volume, and we present two methods – both methods can achieve greater than 9% accuracy. Finally, we demonstrate the use of these valves in a device that conducts a multi-step assay for the detection of the malaria protein PfHRP2. Although slightly more complex than devices that do not have moving parts, this valving and automation toolkit considerably expands the capabilities of paper microfluidic devices. Components of this toolkit can be used to conduct arbitrarily complex, multi-step fluidic operations on paper-based devices, as demonstrated in the malaria assay device. PMID:25606810
High speed exhaust gas recirculation valve
Fensom, Rod; Kidder, David J.
2005-01-18
In order to minimize pollutants such as Nox, internal combustion engines typically include an exhaust gas recirculation (EGR) valve that can be used to redirect a portion of exhaust gases to an intake conduit, such as an intake manifold, so that the redirected exhaust gases will be recycled. It is desirable to have an EGR valve with fast-acting capabilities, and it is also desirable to have the EGR valve take up as little space as possible. An exhaust gas recirculation valve is provided that includes an exhaust passage tube, a valve element pivotally mounted within the exhaust passage tube, a linear actuator; and a gear train. The gear train includes a rack gear operatively connected to the linear actuator, and at least one rotatable gear meshing with the rack gear and operatively connected to the valve element to cause rotation of the valve element upon actuation of the linear actuator. The apparatus provides a highly compact package having a high-speed valve actuation capability.
Massive Gas Injection Valve Development for NSTX-U
Raman, R. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Plunkett, G. J. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States); Way, W.-S. [Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
2016-05-01
NSTX-U research will offer new insight by studying gas assimilation efficiencies for MGI injection from different poloidal locations using identical gas injection systems. In support of this activity, an electromagnetic MGI valve has been built and tested. The valve operates by repelling two conductive disks due to eddy currents induced on them by a rapidly changing magnetic field created by a pancake disk solenoid positioned beneath the circular disk attached to a piston. The current is driven in opposite directions in the two solenoids, which creates a cancelling torque when the valve is operated in an ambient magnetic field, as would be required in a tokamak installation. The valve does not use ferromagnetic materials. Results from the operation of the valve, including tests conducted in 1 T external magnetic fields, are described. The pressure rise in the test chamber is measured directly using a fast time response baratron gauge. At a plenum pressure of just 1.38 MPa (~200 psig), the valve injects 27 Pa.m^3 (~200 Torr.L) of nitrogen with a pressure rise time of 3 ms.
A valved hepatic portoduodenal intestinal conduit for biliary atresia.
Tanaka, K; Shirahase, I; Utsunomiya, H; Katayama, T; Uemoto, S; Asonuma, K; Inomata, Y; Ozawa, K
1991-03-01
Forty-six consecutive patients with biliary atresia were operated on at our institution during the 11-year period between 1978 and 1989. Their ages at operation ranged from 18 to 153 days (mean, 59 days). After dissecting the porta hepatis structures by Kasai operation, a biliointestinal anastomosis was constructed with a valved hepatic portoduodenal intestinal conduit in all cases. The intestinal valve is an intussuscepted muscular valve. Valvular function was examined radiologically. The upper gastrointestinal series demonstrated no reflux of contrast material into the conduit proximal to the valve and liver scintigraphy demonstrated that radioactive isotope drained readily into the duodenum through the valve. Thirty-nine of the forty-six patients (85%) had bile drainage after initial operation. At present 30 patients (65%) are alive without jaundice, 6 (13%) are alive with jaundice, and 10 (22%) are dead. The 5-year jaundice-free survival rate was 64%. Cholangitis occurred in 9 of 39 patients (23%) who had obtained apparent bile drainage: 5 had tractable cholangitis and 4 had refractory cholangitis. Reoperation restored bile flow in 2 of 8 patients who abruptly ceased to have bile drainage without cholangitis. In conclusion, with a valved hepatic portoduodenal intestinal conduit, the incidence of cholangitis was decreased, its medical control became easier, and the survival rate was improved.
Performance characterization of a solenoid-type gas valve for the H- magnetron source at FNAL
NASA Astrophysics Data System (ADS)
Sosa, A.; Bollinger, D. S.; Karns, P. R.
2017-08-01
The magnetron-style H- ion sources currently in operation at Fermilab use piezoelectric gas valves to function. This kind of gas valve is sensitive to small changes in ambient temperature, which affect the stability and performance of the ion source. This motivates the need to find an alternative way of feeding H2 gas into the source. A solenoid-type gas valve has been characterized in a dedicated off-line test stand to assess the feasibility of its use in the operational ion sources. H- ion beams have been extracted at 35 keV using this valve. In this study, the performance of the solenoid gas valve has been characterized measuring the beam current output of the magnetron source with respect to the voltage and pulse width of the signal applied to the gas valve.
Operating Temperatures of a Sodium-Cooled Exhaust Valve as Measured by a Thermocouple
NASA Technical Reports Server (NTRS)
Sanders, J. C.; Wilsted, H. D.; Mulcahy, B. A.
1943-01-01
A thermocouple was installed in the crown of a sodium-cooled exhaust valve. The valve was then tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 F was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 rpm. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., inside BOPs, and drill-string safety valves? 250.445 Section 250.445 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.445 What...
Code of Federal Regulations, 2011 CFR
2011-07-01
..., inside BOPs, and drill-string safety valves? 250.445 Section 250.445 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop...
Outcomes of Aortic Valve-Sparing Operations in Marfan Syndrome.
David, Tirone E; David, Carolyn M; Manlhiot, Cedric; Colman, Jack; Crean, Andrew M; Bradley, Timothy
2015-09-29
In many cardiac units, aortic valve-sparing operations have become the preferred surgical procedure to treat aortic root aneurysm in patients with Marfan syndrome, based on relatively short-term outcomes. This study examined the long-term outcomes of aortic valve-sparing operations in patients with Marfan syndrome. All patients with Marfan syndrome operated on for aortic root aneurysm from 1988 through 2012 were followed prospectively for a median of 10 years. Follow-up was 100% complete. Time-to-event analyses were calculated using the Kaplan-Meier method with log-rank test for comparisons. A total of 146 patients with Marfan syndrome had aortic valve-sparing operations. Reimplantation of the aortic valve was performed in 121 and remodeling of the aortic root was performed in 25 patients. Mean age was 35.7 ± 11.4 years and two-thirds were men. Nine patients had acute, 2 had chronic type A, and 3 had chronic type B aortic dissections before surgery. There were 1 operative and 6 late deaths, 5 caused by complications of dissections. Mortality rate at 15 years was 6.8 ± 2.9%, higher than the general population matched for age and sex. Five patients required reoperation on the aortic valve: 2 for endocarditis and 3 for aortic insufficiency. Three patients developed severe, 4 moderate, and 3 mild-to-moderate aortic insufficiency. Rate of aortic insufficiency at 15 years was 7.9 ± 3.3%, lower after reimplantation than remodeling. Nine patients developed new distal aortic dissections during follow-up. Rate of dissection at 15 years was 16.5 ± 3.4%. Aortic valve-sparing operations in patients with Marfan syndrome were associated with low rates of valve-related complications in long-term follow-up. Residual and new aortic dissections were the leading cause of death. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A modified repair technique for tricuspid incompetence in Ebstein's anomaly.
Hetzer, R; Nagdyman, N; Ewert, P; Weng, Y G; Alexi-Meskhisvili, V; Berger, F; Pasic, M; Lange, P E
1998-04-01
A modified technique for tricuspid valve repair in Ebstein's anomaly restructures the valve mechanism at the level of the true tricuspid anulus by using the most mobile leaflet for valve closure without plication of the atrialized chamber. Midterm results of this therapeutic approach for patients with Ebstein's anomaly and tricuspid valve incompetence are reported. Between October 1988 and April 1997, the incompetent tricuspid valve was repaired with our technique in 19 patients (12 female, 7 male; 2 to 54 years, mean 21 years). The indication for operation was congestive heart failure of various degrees in all patients. Tricuspid incompetence was grade II in two patients, grade III in 14, and grade IV in three. Associated congenital malformations were simultaneously repaired (interatrial communication in 18, ventricular septal defect in two, pulmonary stenosis in two, mitral valve prolapse in one). Follow-up ranged between 10 and 103 months (median 28 months) and was complete for all patients. There were no operative deaths. One patient with active endocarditis and pulmonary abscess died 2 months after the operation of recurrent sepsis; there were no late deaths. During follow-up, New York Heart Association functional class improved from 2.8 before the operation to 1.9 without recurrent cyanosis, and tricuspid incompetence decreased from a mean grade of 3.1 to one of 0.9, without any echocardiographic deterioration of the tricuspid valve function or right ventricular dilation. Our technique allows tricuspid valve repair in patients with Ebstein's anomaly, even in cases usually reserved for primary valve replacement, without late functional deterioration.
Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila
2016-06-20
The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.
NASA Astrophysics Data System (ADS)
Dong, Dai; Li, Xiaoning
2015-03-01
High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system. However, traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously. A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system. A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design. Mathematical models of the opening process and flow rate of the valve are established. Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response. Corresponding formulas to solve 4 parts of the response time are derived. Key factors that influence the opening response time are analyzed. According to the mathematical model of the valve, a simulation of the opening process is carried out by MATLAB. Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve. Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool. The experimental results are in agreement with the simulated results, therefore the validity of the theoretical analysis is verified. Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa. The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s. According to the result of the load driving test, the valve can meet the demands of the driving system. The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate.
[Minor strut fracture of the Björk-Shiley mitral valve].
Sugita, T; Yasuda, R; Watarida, S; Onoe, M; Tabata, R; Mori, A
1990-06-01
In May, 1982, a 49-year-old man underwent mitral valve replacement (MVR) in our hospital with a 31 mm Björk-Shiley prosthesis for mitral regurgitation. He had been doing well until his episode of palpitation and dyspnea of sudden onset, and was transferred to our ICU with severe cardiogenic shock in Aug, 1986. Chest X-ray film revealed pulmonary edema and breakage of the valve with migration of the disc and the minor strut of the prosthesis. He was operated upon 5 hours after the onset of his complaints. The minor strut was removed from the left upper pulmonary vein and mitral valve re-replacement was done with a 29 mm Björk-Shiley Monostrut valve. The disc which had dislocated into the abdominal aorta was also recovered on the twenty-third post operative day. His postoperative course was uneventful. Immediate diagnosis and subsequent re-operation is absolute indication for rescue from acute cardiac failure due to mechanical failure of any prosthetic valve.
Alkherayf, Fahad; Abou Al-Shaar, Hussam; Awad, Michael
2015-09-01
To evaluate the clinical outcomes and complications rate among idiopathic intracranial hypertension (IIH) patients who underwent lumboperitoneal (LP) shunt insertion with a programmable Strata valve. We retrospectively evaluated patients who underwent LP shunt with a programmable Strata valve insertion at the University of Ottawa Civic Hospital from November 2012 to June 2013. The demographic data, clinical symptoms, opening pressure, pre-operative and post-operative visual fields, neuroimaging, visual acuity, disc status, and complications were recorded and analyzed. Seven female patients with IIH underwent insertion of an LP shunt with a programmable Strata valve. The mean opening pressure was 35.8 cm H2O. The initial valve setting was 1.5, and four patients required post-operative valve pressure adjustment. All patients showed significant improvement in objective visual testing at follow-up as well as less frequent headaches. None of the patients developed intra- or post-operative complications. LP shunts with programmable Strata valve systems are a potential alternative to conventional LP and programmable ventriculoperitoneal shunt systems as well as optic nerve sheath fenestration, due to their potential in avoiding brain injury, lower failure and complication rates, lower intracranial hypotension incidence, and flexibility in adjusting valve pressure settings post-operatively evading under- and overdrainage complications. They should be considered for the management of IIH instead of early design LP systems and VP shunts. A randomized multi-center trial should be conducted to compare the efficacy of these surgical techniques. Copyright © 2015 Elsevier B.V. All rights reserved.
Multiple source/multiple target fluid transfer apparatus
Turner, Terry D.
1997-01-01
A fluid transfer apparatus includes: a) a plurality of orifices for connection with fluid sources; b) a plurality of orifices for connection with fluid targets; c) a set of fluid source conduits and fluid target conduits associated with the orifices; d) a pump fluidically interposed between the source and target conduits to transfer fluid therebetween; e) a purge gas conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass a purge gas under pressure; f) a solvent conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass solvent, the solvent conduit including a solvent valve; g) pump control means for controlling operation of the pump; h) purge gas valve control means for controlling operation of the purge gas valve to selectively impart flow of purge gas to the fluid source conduits, fluid target conduits and pump; i) solvent valve control means for controlling operation of the solvent valve to selectively impart flow of solvent to the fluid source conduits, fluid target conduits and pump; and j) source and target valve control means for controlling operation of the fluid source conduit valves and the fluid target conduit valves to selectively impart passage of fluid between a selected one of the fluid source conduits and a selected one of the fluid target conduits through the pump and to enable passage of solvent or purge gas through selected fluid source conduits and selected fluid target conduits.
Multiple source/multiple target fluid transfer apparatus
Turner, T.D.
1997-08-26
A fluid transfer apparatus includes: (a) a plurality of orifices for connection with fluid sources; (b) a plurality of orifices for connection with fluid targets; (c) a set of fluid source conduits and fluid target conduits associated with the orifices; (d) a pump fluidically interposed between the source and target conduits to transfer fluid there between; (e) a purge gas conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass a purge gas under pressure; (f) a solvent conduit in fluid communication with the fluid source conduits, fluid target conduits and pump to receive and pass solvent, the solvent conduit including a solvent valve; (g) pump control means for controlling operation of the pump; (h) purge gas valve control means for controlling operation of the purge gas valve to selectively impart flow of purge gas to the fluid source conduits, fluid target conduits and pump; (i) solvent valve control means for controlling operation of the solvent valve to selectively impart flow of solvent to the fluid source conduits, fluid target conduits and pump; and (j) source and target valve control means for controlling operation of the fluid source conduit valves and the fluid target conduit valves to selectively impart passage of fluid between a selected one of the fluid source conduits and a selected one of the fluid target conduits through the pump and to enable passage of solvent or purge gas through selected fluid source conduits and selected fluid target conduits. 6 figs.
Siddiqui, Maria Tariq; Hasan, Asif; Mohsin, Shazia; Hamid, Mohammad; Amanullah, Muhammad Muneer
2012-10-01
The focus of this study is to share the experience and outcomes of Contegra graft implantation in the paediatric and adult population in Pakistan. Between May 2007 and July 2011, 16 patients, underwent implantation of a Contegra valved conduit. All operations were performed through a median sternotomy with cardiopulmonary bypass. Indications included: Pulmonary atresia with ventricular septal defect (n = 11), Tetralogy of Fallot with absent Pulmonary Valve (PV) syndrome (n = 2), double outlet right ventricle, transposition of great arteries and pulmonary stenosis (n = 1), isolated aortic valve disease (n = 1) and a pseudo-aneurysm with infective endocarditis (n = 1).Conduit sizes varied between 16-22 mm. The three in hospital deaths were unrelated to the Contegra valved conduit. One patient was lost to follow up. Of the 12 survivors, 10 are currently free from re-operation or complications related to the conduit while one needed distal pulmonary artery dilatation owing to critical stenosis and another had severe Valvular regurgitation. Echocardiographic evaluation of the Contegra valved conduit demonstrated no haemodynamically significant valve regurgitation in 10 patients. In this small review of 16 operations using the Contegra valved conduit for Right Venticular Outflow Tract (RVOT) reconstruction in the paediatric population, we observed good post operative results concerning conduit function. The Contegra conduit provides an excellent substitute to the homograft with satisfactory early and mid-term results though long-term results are awaited in Pakistan.
Oh, Se Jin; Park, Samina; Kim, Jun Sung; Kim, Kyung-Hwan; Kim, Ki Bong; Ahn, Hyuk
2013-07-01
The authors' clinical experience is presented of non-structural valvular dysfunction of the prosthetic aortic valve caused by pannus ingrowth during the late postoperative period after previous heart valve surgery. Between January 1999 and April 2012, at the authors' institution, a total of 33 patients underwent reoperation for increased mean pressure gradient of the prosthetic aortic valve. All patients were shown to have pannus ingrowth. The mean interval from the previous operation was 16.7 +/- 4.3 years, and the most common etiology for the previous aortic valve replacement (AVR) was rheumatic valve disease. The mean effective orifice area index (EOAI) of the previous prosthetic valve was 0.97 +/- 0.11 cm2/m2, and the mean pressure gradient on the aortic prosthesis before reoperation was 39.1 +/- 10.7 mmHg. Two patients (6.1%) died in-hospital, and late death occurred in six patients (18.2%). At the first operation, 30 patients underwent mitral or tricuspid valve surgery as a concomitant procedure. Among these operations, mitral valve replacement (MVR) was combined in 24 of all 26 patients with rheumatic valve disease. Four patients underwent pannus removal only while the prosthetic aortic valve was left in place. The mean EOAI after reoperation was significantly increased to 1.16 +/- 0.16 cm2/m2 (p < 0.001), and the mean pressure gradient was decreased to 11.9 +/- 1.9 mmHg (p < 0.001). Non-structural valvular dysfunction caused by pannus ingrowth was shown in patients with a small EOAI of the prosthetic aortic valve and combined MVR for rheumatic disease. As reoperation for pannus overgrowth showed good clinical outcomes, an aggressive resection of pannus and repeated AVR should be considered in symptomatic patients to avoid the complications of other cardiac diseases.
Ceramic valve development for heavy-duty low heat rejection diesel engines
NASA Technical Reports Server (NTRS)
Weber, K. E.; Micu, C. J.
1989-01-01
Monolithic ceramic valves can be successfully operated in a heavy-duty diesel engine, even under extreme low heat rejection operating conditions. This paper describes the development of a silicon nitride valve from the initial design stage to actual engine testing. Supplier involvement, finite element analysis, and preliminary proof of concept demonstration testing played a significant role in this project's success.
Performance Characterization of a Solenoid-type Gas Valve for the H- Magnetron Source at FNAL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sosa, A.; Bollinger, D. S.; Karns, P. R.
2016-09-06
The magnetron-style H- ion sources currently in operation at Fermilab use piezoelectric gas valves to function. This kind of gas valve is sensitive to small changes in ambient temperature, which affect the stability and performance of the ion source. This motivates the need to find an alternative way of feeding H2 gas into the source. A solenoid-type gas valve has been characterized in a dedicated off-line test stand to assess the feasibility of its use in the operational ion sources. H- ion beams have been extracted at 35 keV using this valve. In this study, the performance of the solenoidmore » gas valve has been characterized measuring the beam current output of the magnetron source with respect to the voltage and pulse width of the signal applied to the gas valve.« less
Operating Temperatures of a Sodium-Cooled Exhaust Valve as Measured by a Thermocouple
NASA Technical Reports Server (NTRS)
Sanders, J C; Wilsted, H D; Mulcahy, B A
1943-01-01
Report presents the results of a thermocouple installed in the crown of a sodium-cooled exhaust valve. The valve was tested in an air-cooled engine cylinder and valve temperatures under various engine operating conditions were determined. A temperature of 1337 degrees F. was observed at a fuel-air ratio of 0.064, a brake mean effective pressure of 179 pounds per square inch, and an engine speed of 2000 r.p.m. Fuel-air ratio was found to have a large influence on valve temperature, but cooling-air pressure and variation in spark advance had little effect. An increase in engine power by change of speed or mean effective pressure increased the valve temperature. It was found that the temperature of the rear-spark-plug bushing was not a satisfactory indication of the temperature of the exhaust valve.
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3556 Section 63... system and add-on control device operating limits during the performance test? During the performance... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.3546 Section 63.3546... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Code of Federal Regulations, 2014 CFR
2014-07-01
... capture system and add-on control device operating limits during the performance test? 63.3546 Section 63... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3546 Section 63... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... minimum operating limit for that specific capture device or system of multiple capture devices. The...
Code of Federal Regulations, 2012 CFR
2012-07-01
... capture system and add-on control device operating limits during the performance test? 63.3556 Section 63... system and add-on control device operating limits during the performance test? During the performance... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure...
Lee Henry, Christopher; Ko, Jong Mi; Henry, Albert Carl; Matter, Gregory John
2011-01-01
Aortic valve replacement following an earlier coronary artery bypass grafting (CABG) procedure is fairly common. When this situation occurs, the type of valve dysfunction is usually stenosis (with or without regurgitation), and whether it was missed at the time of the earlier CABG or developed subsequently is usually unclear. We attempted to determine the survival in patients who had had aortic valve replacement after 2 previous CABG procedures. We describe 12 patients who had aortic valve replacement for aortic stenosis; rather than one previous CABG operation, all had had 2 previous CABG procedures. Only one patient died in the early postoperative period after aortic valve replacement, and the remaining 11 were improved substantially: all have lived at least 11 months, and one is still alive at over 101 months after aortic valve replacement. Aortic valve replacement remains beneficial for most patients even after 2 previous CABG procedures. PMID:21307968
Latching Solenoid-Operated Ball Valve
NASA Technical Reports Server (NTRS)
Brudnicki, Myron
1994-01-01
Proposed solenoid-operated ball valve latches in open or closed position until energized to change position. Electrical energy consumed only during opening or closing motion. Valve ball contains central channel through which fluid could flow. Made of highly magnetically permeable steel. When appropriate coil(s) energized by brief pulse (or pulses) of electrical current at appropriate polarity, ball rotates clockwise until permanent magnets come to rest against hard stops in housing, and inlet and outlet ports aligned with central channel so fluid flows through valve. Magnets adhere to stops by magnetic attraction, latching valve in open position. To close valve, appropriate coil(s) energized by pulse (or pulses) of appropriate polarity to generate magnetic forces rotating ball counterclockwise until magnets make contact with hard stops, and inlet and outlet ports sealed.
Improved solenoid valve design
NASA Technical Reports Server (NTRS)
Evans, J.
1969-01-01
Modified solenoid valve reduces valve seat loading by eliminating off-center operation of the armature, reducing the poppet size and spring-cushioning its impact, and reducing armature impact with a poppet guide stop.
Biocor No- React stentless aortic valve--short-term results.
Von Oppell, U O; Stemmet, F; Levetan, B; Heijke, S A; Brink, J
2001-01-01
Short-term results of the bioprosthetic Biocor No-React composite porcine stentless aortic valve (Biocor Industria e Pesquisas LTDA, Belo Horizonte, Brazil) implanted in patients in whom anticoagulation was thought to be contraindicated or expected to be non-compliant. Retrospective review of 52 consecutive prospective patients in whom this valve was implanted, between September 1994 and May 1998. Average age was 44 +/- 17 years; 75% of patients were operated on for rheumatic heart disease and combined procedures were done in 40% of cases. Early mortality was 5.8%, and related to pre-operative ejection fraction ( P < 0.03), New York Heart Association (NYHA) class (P < 0.01), and bacterial endocarditis (P < 0.04). On discharge, 84% of survivors were in NYHA class I and 16% in class II. The average postoperative prosthetic valve peak gradient on echocardiography was 19.9 +/- 11 mmHg and was related to pre-operative ejection fraction and smaller valve sizes. Postoperative residual trivial or mild aortic regurgitation was seen in 19 patients (36.6%), resolved on follow-up in 10 cases, and did not correlate with structural deterioration, re-operation, mortality, or widening of the non-coronary sinus. The non-coronary aortic sinus was widened on closure, because of perceived crowding of the adjacent stentless valve commisures, in 52% of cases. This was thought to be related to the use of an oblique as opposed to transverse aortotomy. Patient survival, inclusive of operative deaths, was 88.5%, and event-free survival was 80.0% at 4 years. The short-term results of this stentless aortic valve in a young predominantly third-world population group are acceptable, and appear to be superior to the results for mechanical valves in a similar patient group. We would recommend a transverse aortotomy above the sinotubular ridge to be the more appropriate aortotomy incision when using stentless aortic valves.
Minakata, Kenji; Tanaka, Shiro; Tamura, Nobushige; Yanagi, Shigeki; Ohkawa, Yohei; Okonogi, Shuichi; Kaneko, Tatsuo; Usui, Akihiko; Abe, Tomonobu; Shimamoto, Mitsuomi; Takahara, Yoshiharu; Yamanaka, Kazuo; Yaku, Hitoshi; Sakata, Ryuzo
2017-07-25
The aim of this study was to assess the long-term outcomes of aortic valve replacement (AVR) with either mechanical or bioprosthetic valves according to age at operation.Methods and Results:A total of 1,002 patients (527 mechanical valves and 475 bioprosthetic valves) undergoing first-time AVR were categorized according to age at operation: group Y, age <60 years; group M, age 60-69 years; and group O, age ≥70 years). Outcomes were compared on propensity score analysis (adjusted for 28 variables). Hazard ratio (HR) was calculated using the Cox regression model with adjustment for propensity score with bioprosthetic valve as a reference (HR=1). There were no significant differences in overall mortality between mechanical and bioprosthetic valves for all age groups. Valve-related mortality was significantly higher for mechanical valves in group O (HR, 2.53; P=0.02). Reoperation rate was significantly lower for mechanical valves in group Y (HR, 0.16; P<0.01) and group M (no events for mechanical valves). Although the rate of thromboembolic events was higher in mechanical valves in group Y (no events for tissue valves) and group M (HR, 9.05; P=0.03), there were no significant differences in bleeding events between all age groups. The type of prosthetic valve used in AVR does not significantly influence overall mortality.
Fuel and oxidizer valve assembly employs single solenoid actuator
NASA Technical Reports Server (NTRS)
1966-01-01
Valve assembly simultaneously starts or stops the flow of oxidizer and fuel from separate inlet channels to reaction control motors. The assembly combines an oxidizer shutoff valve and a fuel shutoff valve which are mechanically linked and operated by a single high-speed solenoid actuator.
Manouguian, S; Abu-Aishah, N; Neitzel, J
1979-09-01
The experimental results of patch enlargement of the aortic and mitral valve rings with aortic and mitral double valve replacement are reported. The operative technique of this new surgical method is described and the indications are discussed.
Shock-operated valve would automatically protect fluid systems
NASA Technical Reports Server (NTRS)
Branum, L. W.; Wells, G. H.
1966-01-01
Glandless valve shuts down high-pressure fluid systems when severe shock from an explosion or earthquake occurs. The valve uses a pendulum to support the valve closure plug in the open position. When jarred, the valve body is moved relative to the pendulum and the plug support is displaced, allowing the plug to seat and be held by spring pressure.
Enhanced Component Performance Study: Air-Operated Valves 1998-2014
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schroeder, John Alton
2015-11-01
This report presents a performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2014 for the component reliability as reported in the Institute of Nuclear Power Operations (INPO) Consolidated Events Database (ICES). The AOV failure modes considered are failure-to-open/close, failure to operate or control, and spurious operation. The component reliability estimates and the reliability data are trended for the most recent 10-year period, while yearly estimates for reliability are provided for the entire active period. One statistically significantmore » trend was observed in the AOV data: The frequency of demands per reactor year for valves recording the fail-to-open or fail-to-close failure modes, for high-demand valves (those with greater than twenty demands per year), was found to be decreasing. The decrease was about three percent over the ten year period trended.« less
Analysis of Complex Valve and Feed Systems
NASA Technical Reports Server (NTRS)
Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy; Cavallo, Peter; Dash, Sanford
2007-01-01
A numerical framework for analysis of complex valve systems supports testing of propulsive systems by simulating key valve and control system components in the test loop. In particular, it is designed to enhance the analysis capability in terms of identifying system transients and quantifying the valve response to these transients. This system has analysis capability for simulating valve motion in complex systems operating in diverse flow regimes ranging from compressible gases to cryogenic liquids. A key feature is the hybrid, unstructured framework with sub-models for grid movement and phase change including cryogenic cavitations. The multi-element unstructured framework offers improved predictions of valve performance characteristics under steady conditions for structurally complex valves such as pressure regulator valve. Unsteady simulations of valve motion using this computational approach have been carried out for various valves in operation at Stennis Space Center such as the split-body valve and the 10-in. (approx.25.4-cm) LOX (liquid oxygen) valve and the 4-in. (approx.10 cm) Y-pattern valve (liquid nitrogen). Such simulations make use of variable grid topologies, thereby permitting solution accuracy and resolving important flow physics in the seat region of the moving valve. An advantage to this software includes possible reduction in testing costs incurred due to disruptions relating to unexpected flow transients or functioning of valve/flow control systems. Prediction of the flow anomalies leading to system vibrations, flow resonance, and valve stall can help in valve scheduling and significantly reduce the need for activation tests. This framework has been evaluated for its ability to predict performance metrics like flow coefficient for cavitating venturis and valve coefficient curves, and could be a valuable tool in predicting and understanding anomalous behavior of system components at rocket propulsion testing and design sites.
77 FR 47329 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-08
... inspection to determine if certain motor operated valve actuators for the fuel tanks are installed, and.... That AD requires an inspection to determine if certain motor operated valve actuators for the fuel...
Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
MISKA, C.R.
1 inch gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.
Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
VAN KATWIJK, C.
1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fall closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.
Worcester 1 Inch Solenoid Actuated Gas Operated SCHe System Valves
DOE Office of Scientific and Technical Information (OSTI.GOV)
VAN KATWIJK, C.
1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated.
Robotic mitral valve surgery: overview, methodology, results, and perspective
2016-01-01
Robotic mitral valve repair began in 1998 and has advanced remarkably. It arose from an interest in reducing patient trauma by operating through smaller incisions with videoscopic assistance. In the United States, following two clinical trials, the FDA approved the daVinci Surgical System in 2002 for intra-cardiac surgery. This device has undergone three iterations, eventuating in the current daVinci XI. At present it is the only robotic device approved for mitral valve surgery. Many larger centers have adopted its use as part of their routine mitral valve repair armamentarium. Although these operations have longer perfusion and arrest times, complications have been either similar or less than other traditional methods. Preoperative screening is paramount and leads to optimal patient selection and outcomes. There are clear contraindications, both relative and absolute, that must be considered. Three-dimensional (3D) echocardiographic studies optimally guide surgeons in operative planning. Herein, we describe the selection criteria as well as our operative management during a robotic mitral valve repair. Major complications are detailed with tips to avoid their occurrence. Operative outcomes from the author’s series as well as those from the largest experiences in the United States are described. They show that robotic mitral valve repair is safe and effective, as well as economically reasonable due to lower costs of hospitalization. Thus, the future of this operative technique is bright for centers adopting the “heart team” approach, adequate clinical volume and a dedicated and experienced mitral repair surgeon. PMID:27942486
Microblower assisted barometric valve
Rossabi, Joseph; Hyde, Warren K.; Riha, Brian D.; Jackson, Dennis G.; Sappington, Frank
2005-12-06
A gas exchange apparatus is provided which provides for both passive fluid flow and blower associated fluid flow through a barometric valve. A battery powered blower is provided which allows for operation of the barometric valve during times when the barometric valve would otherwise be closed, and provides for enhanced volume of gas exchange.
Liquid rocket valve assemblies
NASA Technical Reports Server (NTRS)
1973-01-01
The design and operating characteristics of valve assemblies used in liquid propellant rocket engines are discussed. The subjects considered are as follows: (1) valve selection parameters, (2) major design aspects, (3) design integration of valve subassemblies, and (4) assembly of components and functional tests. Information is provided on engine, stage, and spacecraft checkout procedures.
Atluri, Pavan; Stetson, Robert L; Hung, George; Gaffey, Ann C; Szeto, Wilson Y; Acker, Michael A; Hargrove, W Clark
2016-02-01
Mitral valve surgery is increasingly performed through minimally invasive approaches. There are limited data regarding the cost of minimally invasive mitral valve surgery. Moreover, there are no data on the specific costs associated with mitral valve surgery. We undertook this study to compare the costs (total and subcomponent) of minimally invasive mitral valve surgery relative to traditional sternotomy. All isolated mitral valve repairs performed in our health system from March 2012 through September 2013 were analyzed. To ensure like sets of patients, only those patients who underwent isolated mitral valve repairs with preoperative Society of Thoracic Surgeons scores of less than 4 were included in this study. A total of 159 patients were identified (sternotomy, 68; mini, 91). Total incurred direct cost was obtained from hospital financial records. Analysis demonstrated no difference in total cost (operative and postoperative) of mitral valve repair between mini and sternotomy ($25,515 ± $7598 vs $26,049 ± $11,737; P = .74). Operative costs were higher for the mini cohort, whereas postoperative costs were significantly lower. Postoperative intensive care unit and total hospital stays were both significantly shorter for the mini cohort. There were no differences in postoperative complications or survival between groups. Minimally invasive mitral valve surgery can be performed with overall equivalent cost and shorter hospital stay relative to traditional sternotomy. There is greater operative cost associated with minimally invasive mitral valve surgery that is offset by shorter intensive care unit and hospital stays. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
33 CFR 149.120 - What are the requirements for manually operated shutoff valves?
Code of Federal Regulations, 2010 CFR
2010-07-01
... manually operated shutoff valves? 149.120 Section 149.120 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION, AND EQUIPMENT Pollution Prevention Equipment § 149.120 What are the requirements for manually operated shutoff...
Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.
Ohta, Y; Kikuta, Y; Shimooka, T; Mitamura, Y; Yuhta, T; Dohi, T
2000-04-01
Conventional bileaflet prosthetic mechanical heart valves close passively with backflow. Naturally, the valve has problems associated with closure, such as backflow, water hammer effect, and fracture of the leaflet. On the other hand, in the case of the natural aortic valve, the vortex flow in the sinus of Valsalva pushes the leaflet to close, and the valve starts the closing motion earlier than the prosthetic valve as the forward flow decelerates. This closing mechanism is thought to decrease backflow at valve closure. In this study, we propose a new bileaflet mechanical valve resembling a drawbridge in shape, and the prototype valve was designed so that the leaflet closes with the help of the vortex flow in the sinus. The test valve was made of aluminum alloy, and its closing motion was compared to that of the CarboMedics (CM) valve. Both valves were driven by a computer controlled hydraulic mock circulator and were photographed at 648 frames/s by a high speed charge-coupled device (CCD) camera. Each frame of the valve motion image was analyzed with a personal computer, and the opening angles were measured. The flow rate was set as 5.0 L/min. The system was pulsed with 70 bpm, and the systolic/diastolic ratio was 0.3. Glycerin water was used as the circulation fluid at room temperature, and polystyrene particles were used to visualize the streamline. The model of the sinus of Valsalva was made of transparent silicone rubber. As a result, high speed video analysis showed that the test valve started the closing motion 41 ms earlier than the CM valve, and streamline analysis showed that the test valve had a closing mechanism similar to the natural one with the effect of vortex flow. The structure of the test valve was thought to be effective for soft closure and could solve problems associated with closure.
Advanced technology for space shuttle auxiliary propellant valves
NASA Technical Reports Server (NTRS)
Wichmann, H.
1973-01-01
Valves for the gaseous hydrogen/gaseous oxygen shuttle auxiliary propulsion system are required to feature low leakage over a wide temperature range coupled with high cycle life, long term compatibility and minimum maintenance. In addition, those valves used as thruster shutoff valves must feature fast response characteristics to achieve small, repeatable minimum impulse bits. These valve technology problems are solved by developing unique valve components such as sealing closures, guidance devices, and actuation means and by demonstrating two prototype valve concepts. One of the prototype valves is cycled over one million cycles without exceeding a leakage rate of 27 scc's per hour at 450 psia helium inlet pressure throughout the cycling program.
Development of myoelectric control type speaking valve with low flow resistance
NASA Astrophysics Data System (ADS)
Ooe, Katsutoshi; Sakurai, Kohei; Mimaki, Shinya
2015-12-01
We aimed to develop welfare devices for patients with phonation disorder. One of these devices is the electrical controltype speaking valve system. The conventional speaking valves have one-way valve architecture, they open when the user breathes in, and they close when user breathes out and produce voices. This type is very simple and tough, but some users feel closeness in case of exhalation without phonation. This problem is caused by its mechanism what can not be controlled by user's will. Therefore, we proposed an electrical control-type speaking valve system to resolve this problem. This valve is controlled by neck myoelectric signal of sternohyoid muscle. From our previous report, it was clarified that this valve had better performance about easy-to-breath. Furthermore, we proposed the compact myoelectric control-type speaking valve system. The new-type speaking valve was enough small to attach the human body, and its opening area is larger than that of conventional one. Additionally, we described the improvement of flow channel shape by using of FEM analysis. According to the result of the analysis, it was clarified that the shape-improved speaking valve gets the low flow resistance channel in case of inspiration. In this report, we tried to make the flow resistance lower by the shape of current plates, in case of both inspiration and exhalation. From the result of FEM analysis, our speaking valve could get better flow channel than older one.
Microfluidic valve with cored glass microneedle for microinjection.
Lee, Sanghoon; Jeong, Wonje; Beebe, David J
2003-08-01
In this paper, a new microinjection device was constructed by fusing a glass microneedle and a PDMS-based microvalve. The microneedle was fabricated via traditional micropipette pulling. The PDMS-based microvalve regulates the fluid flow in the microchannel and microneedle. The 'ON/OFF' operation of the valve was controlled by manually supplied pneumatic pressure. The valve membrane utilized a two level geometry to improve control at low flow rates. The relation between pressure and flow was measured and the results showed that very small volumes of fluid (>1 nl) could be controlled. The valve operation was investigated by monitoring the tip of the needle and pneumatic pressure simultaneously and it demonstrated very stable 'ON/OFF' operation to the pressure change.
NASA Technical Reports Server (NTRS)
Friedell, M. V. (Inventor)
1978-01-01
A disconnect composed basically of two halves each consisting of a poppet valve operable to isolate fluid with essentially zero fluid loss is presented. The two halves are coupled together by a quickly releasable coupling which may be either a coupling ring tightened or loosened by a twisting motion, or a clamp operated by a pivoted to prevent disconnecting the two halves until both valves are in closed condition. The positive feature of the device is one requiring a valve closing step before a disconnect step, and takes structural form in an accentric lobe mounted on the valve operating stem. If some obstruction prevents the poppet from moving to its seat, the eccentric lobe cannot be rotated to the closed position, and the interlock prevents a disconnect.
Oborny, Michael C.; Paul, Phillip H.; Hencken, Kenneth R.; Frye-Mason, Gregory C.; Manginell, Ronald P.
2001-01-01
A valve for controlling fluid flows. This valve, which includes both an actuation device and a valve body provides: the ability to incorporate both the actuation device and valve into a unitary structure that can be placed onto a microchip, the ability to generate higher actuation pressures and thus control higher fluid pressures than conventional microvalves, and a device that draws only microwatts of power. An electrokinetic pump that converts electric potential to hydraulic force is used to operate, or actuate, the valve.
[Tricuspid valve regurgitation : Indications and operative techniques].
Lange, R; Piazza, N; Günther, T
2017-11-01
Functional tricuspid valve (TV) regurgitation secondary to left heart disease (e.g. mitral insufficiency and stenosis) is observed in 75% of the patients with TV regurgitation and is thus the most common etiology; therefore, the majority of patients who require TV surgery, undergo concomitant mitral and/or aortic valve surgery. Uncorrected moderate and severe TV regurgitation may persist or even worsen after mitral valve surgery, leading to progressive heart failure and death. Patients with moderate to severe TV regurgitation show a 3-year survival rate of 40%. Surgery is indicated in patients with severe TV regurgitation undergoing left-sided valve surgery and in patients with severe isolated primary regurgitation without severe right ventricular (RV) dysfunction. For patients requiring mitral valve surgery, tricuspid valve annuloplasty should be considered even in the absence of significant regurgitation, when severe annular dilatation (≥40 mm or >21 mm/m 2 ) is present. Functional TV regurgitation is primarily treated with valve reconstruction which carries a lower perioperative risk than valve replacement. Valve replacement is rarely required. Tricuspid valve repair with ring annuloplasty is associated with better survival and a lower reoperation rate than suture annuloplasty. Long-term results are not available. The severity of the heart insufficiency and comorbidities (e.g. renal failure and liver dysfunction) are the essential determinants of operative mortality and long-term survival. Tricuspid valve reoperations are rarely necessary and associated with a considerable mortality.
[Status of aortic valve reconstruction and Ross operation in aortic valve diseases].
Sievers, Hans H
2002-08-01
At first glance the aortic valve is a relative simple valve mechanism connecting the left ventricle and the ascending aorta. Detailed analysis of the different components of the aortic valve including the leaflets and sinuses revealed a complex motion of each part leading to a perfect durable valve mechanism at rest and during exercise. Theoretically, the reconstruction or imitation of these structures in patients with aortic valve disease should lead to optimal results. Prerequisite is the exact knowledge of the important functional characteristics of the aortic valve. The dynamic behavior of the aortic root closely harmonizing with the leaflets not only warrants stress minimizing and valve durability, but also optimizes coronary flow, left ventricular function and aortic impedance. The newly discovered contractile capacity of the leaflets and the root components are important for tuning the dynamics. Isolated reconstruction of the aortic valve such as decalcification, commissurotomy, plication of ring or leaflets of a tricuspid aortic valve and cusp extension are seldom indicated in contrast to the reconstruction of the bicuspid insufficient valve. Proper indication and skilled techniques lead to excellent hemodynamic and clinical intermediate-term result up to 7 years after reconstruction. Latest follow-up revealed a mean aortic insufficiency of 0.7, maximal pressure gradient of 11.4 +/- 8.5 mm Hg with zero hospital or late mortality, reoperation or thromboembolic events in 22 patients. The reconstructive techniques for aortic root aneurysm and/or type A dissection according to David or Yacoub have become routine procedures in the last 10 years. The hemodynamic and clinical results are excellent with low reoperation rate and very low risk of thromboembolism. Generally, a maximal diameter of the root of 5 cm is indicative for performing the operation. In patients with Marfan's syndrome the reconstruction should be advanced even with smaller diameters especially if these are progressive and combined with aortic insufficiency. ROSS-OPERATION: The Ross-Operation includes the replacement of the diseased aortic valve with the pulmonary autograft and reconstruction of the right ventricular outflow tract using a homograft. The hemodynamic results are excellent regarding the autograft and also the clinical results with very low thromboembolic risk and acceptable reoperation rate. This method is especially indicated for active young patients, women, who desire children, athletes and patients in general, who like to avoid long-term anticoagulation. In some cases the homograft may develop a dysfunction predominantly a pulmonary stenosis requiring reoperation. In the author's series of 245 Ross-operations in 12 years the homograft had to be replaced in 4 cases without letality. Innovative, decellularized homografts with the potential to repopulate with autologeous cells show promising results after 1 year of clinical implantation without signs of antibody development. Probably these tissue-engineered modification may improve the homograft results. The reconstructive techniques of the aortic valve and the Ross-operation have a certain risk of reoperation that must be weighed against the advantages of very low hospital and late valve related death, excellent hemodynamics, very low risk of macro- and microembolism as well as bleeding, lack of long-term anticoagulation and unrestricted life-style.
Habriielian, A V; Smorzhevs'kyĭ, V I; Onishchenko, V F; Beleĭovych, V V; Topchu, Ie I; Domans'kyĭ, T M; Myroniuk, O I
2011-07-01
Comparative analysis of the results of plastic operations performance on a tricuspid valve (TV) in patients, suffering cardiac insufficiency in terminal stage, was conducted. In late postoperative period the indices of intracardial hemodynamics (cardiac output fraction, regurgitation on TV) and clinical features (severity of symptoms, quality of life) after plastic operations, using a support ring, have differed significantly from those after performance of a sutured plasty. The valve function during five years was secured in 91.1% of patients.
Investigation into the Cyclic Strength of the Bodies of Steam Shutoff Valves from 10Kh9MFB-Sh Steel
NASA Astrophysics Data System (ADS)
Skorobogatykh, V. N.; Kunavin, S. A.; Prudnikov, D. A.; Shchenkova, I. A.; Bazhenov, A. M.; Zadoinyi, V. A.; Starkovskii, G. L.
2018-02-01
Steam shutoff valves are operated under complex loading conditions at thermal and nuclear power stations. In addition to exposure to high temperature and stresses resulting in fatigue, these valves are subjected to cyclic loads in heating-up-cooling down, opening-closing, etc. cycles. The number of these cycles to be specified in designing the valves should not exceed the maximum allowable value. Hence, the problem of cyclic failure rate of steam shutoff valve bodies is critical. This paper continues the previous publications about properties of the construction material for steam shutoff valve bodies (grade 10Kh9MFB-Sh steel) produced by electroslag melting and gives the results of investigation into the cyclic strength of this material. Fatigue curves for the steal used for manufacturing steam shutoff valve bodies are presented. The experimental data are compared with the calculated fatigue curves plotted using the procedures outlined in PNAE G-002-986 and RD 10-249-98. It is confirmed that these procedures may be used in designing valve bodies from 10Kh9MFB-Sh steel. The effect of the cyclic damage after preliminary cyclic loading of the specimens according to the prescribed load conditions on the high-temperature strength of the steel is examined. The influence of cyclic failure rate on the long-term strength was investigated using cylindrical specimens with a smooth working section in the as-made conditions and after two regimes of preliminary cyclic loading (training) at a working temperature of 570°C and the number of load cycles exceeding the design value, which was 2 × 103 cycles. The experiments corroborated that the material (10Kh9MFB-Sh steel) of the body manufactured by the method of electroslag melting had high resistance to cyclic failure rate. No effect of cyclic damages in the metal of the investigated specimens on the high-temperature strength has been found.
Frostless heat pump having thermal expansion valves
Chen, Fang C [Knoxville, TN; Mei, Viung C [Oak Ridge, TN
2002-10-22
A heat pump system having an operable relationship for transferring heat between an exterior atmosphere and an interior atmosphere via a fluid refrigerant and further having a compressor, an interior heat exchanger, an exterior heat exchanger, a heat pump reversing valve, an accumulator, a thermal expansion valve having a remote sensing bulb disposed in heat transferable contact with the refrigerant piping section between said accumulator and said reversing valve, an outdoor temperature sensor, and a first means for heating said remote sensing bulb in response to said outdoor temperature sensor thereby opening said thermal expansion valve to raise suction pressure in order to mitigate defrosting of said exterior heat exchanger wherein said heat pump continues to operate in a heating mode.
46 CFR 64.41 - Stop valve closure.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Stop valve closure. 64.41 Section 64.41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Standards for an MPT § 64.41 Stop valve closure. A stop valve that operates by a screwed...
33 CFR 183.528 - Fuel stop valves.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Fuel stop valves. 183.528 Section...) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.528 Fuel stop valves. (a) Each electrically operated fuel stop valve in a fuel line between the fuel tank and the engine...
Electromagnetic Smart Valves for Cryogenic Applications
NASA Astrophysics Data System (ADS)
Traum, M. J.; Smith, J. L.; Brisson, J. G.; Gerstmann, J.; Hannon, C. L.
2004-06-01
Electromagnetic valves with smart control capability have been developed and demonstrated for use in the cold end of a Collins-style cryocooler. The toroidal geometry of the valves was developed utilizing a finite-element code and optimized for maximum opening force with minimum input current. Electromagnetic smart valves carry two primary benefits in cryogenic applications: 1) magnetic actuation eliminates the need for mechanical linkages and 2) valve timing can be modified during system cool down and in regular operation for cycle optimization. The smart feature of these electromagnetic valves resides in controlling the flow of current into the magnetic coil. Electronics have been designed to shape the valve actuation current, limiting the residence time of magnetic energy in the winding. This feature allows control of flow through the expander via an electrical signal while dissipating less than 0.0071 J/cycle as heat into the cold end. The electromagnetic smart valves have demonstrated reliable, controllable dynamic cycling. After 40 hours of operation, they suffered no perceptible mechanical degradation. These features enable the development of a miniaturized Collins-style cryocooler capable of removing 1 Watt of heat at 10 K.
Navy Ford (CVN-78) Class Aircraft Carrier Program: Background and Issues for Congress
2013-10-22
states: The CVN 78 is experiencing cost growth due to “first of class” material availability (i.e., valves, actuators ), construction labor...assessment during IOT &E [initial operational test and evaluation]. • The current TEMP [test and evaluation master plan] does not adequately address...developmental testing significantly raises the likelihood of the discovery of platform-level problems during IOT &E. • The Navy plans to deliver CVN-78 in
Heparin-induced thrombocytopenia and heart operation: management with tedelparin.
Altés, A; Martino, R; Gari, M; Cámara, M L; Garín, R; Casas, J I; Fontcuberta, J
1995-02-01
Anticoagulation for cardiopulmonary bypass in the infrequent clinical setting of thrombocytopenia associated with the use of unfractionated heparin is a very serious problem. We describe a case in which a low-molecular-weight heparin (tedelparin) was selected for this purpose based on a platelet aggregation test, permitting adequate anticoagulation during cardiopulmonary bypass for valve replacement. This case report might help establish an adequate anticoagulation protocol when faced with a patient suffering from this condition.
Aortic valve repair leads to a low incidence of valve-related complications.
Aicher, Diana; Fries, Roland; Rodionycheva, Svetlana; Schmidt, Kathrin; Langer, Frank; Schäfers, Hans-Joachim
2010-01-01
Aortic valve replacement for aortic regurgitation (AR) has been established as a standard treatment but implies prosthesis-related complications. Aortic valve repair is an alternative approach, but its mid- to long-term results still need to be defined. Over a 12-year period, 640 patients underwent aortic valve repair for regurgitation of a unicuspid (n=21), bicuspid (n=205), tricuspid (n=411) or quadricuspid (n=3) aortic valve. The mechanism of regurgitation involved prolapse (n=469) or retraction (n=20) of the cusps, and dilatation of the root (n=323) or combined pathologies. Treatment consisted of cusp repair (n=529), root repair (n=323) or a combination of both (n=208). The patients were followed clinically and echocardiographically; follow-up was complete in 98.5% (cumulative follow-up: 3035 patient years). Hospital mortality was 3.4% in the total patient cohort and 0.8% for isolated aortic valve repair. The incidences of thrombo-embolism (0.2% per patient per year) and endocarditis (0.16%per patient per year) were low. Freedom from re-operation at 5 and 10 years was 88% and 81% in bicuspid and 97% and 93% in tricuspid aortic valves (p=0.0013). At re-operation, 13 out of 36 valves could be re-repaired. Freedom from valve replacement was 95% and 90% in bicuspid and 97% and 94% in tricuspid aortic valves (p=0.36). Freedom from all valve-related complications at 10 years was 88%. Reconstructive surgery of the aortic valve is feasible with low mortality in many individuals with aortic regurgitation. Freedom from valve-related complications after valve repair seems superior compared to available data on standard aortic valve replacement. Copyright 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
Assessment of the Melody Valve in the Mitral Position in Young Children by Echocardiography
Freud, Lindsay R.; Marx, Gerald R.; Marshall, Audrey C.; Tworetzky, Wayne; Emani, Sitaram M.
2018-01-01
Objectives Mitral valve replacement (MVR) in young children is limited by lack of small prostheses. Our institution began performing MVR with modified, surgically placed, stented jugular vein grafts (Melody valve) in 2010. We sought to describe key echocardiographic features for pre- and post-operative assessment of this novel form of MVR. Methods The pre- and post-operative echocardiograms of 24 patients who underwent Melody MVR were reviewed. In addition to standard measurements, pre-operative potential measurements of the mitral annulus were performed whereby dimensions were estimated for Melody sizing. A ratio of the narrowest subaortic region in systole to the actual mitral valve dimension (SubA:MV) was assessed for risk of post-operative left ventricular outflow tract obstruction (LVOTO). Results Melody MVR was performed at a median of 8.5 months (5.6 kg) for stenosis (5), regurgitation (3), and mixed disease (16). Pre-operatively, actual mitral z-scores measured hypoplastic (median −3.1 for the lateral (lat) dimension; −2.1 for the antero-posterior (AP) dimension). The potential measurements often had normal z-scores with fair correlation with intra-operative Melody dilation (ρ=0.51 and 0.50 for lat and AP dimensions, both p=0.01). A pre-operative SubA:MV <0.5 was associated with post-operative LVOTO, which occurred in four patients. Post-operatively, mitral gradients substantially improved, with low values relative to the effective orifice area of the Melody valve. No patients had significant regurgitation or perivalvar leak. Conclusions Pre-operative echocardiographic measurements may help guide intra-operative sizing for Melody MVR and identify patients at risk for post-operative LVOTO. Acute post-operative hemodynamic results were favorable; however, on-going assessment is warranted. PMID:27523403
Development of a smart type motor operated valve for nuclear power plants
NASA Astrophysics Data System (ADS)
Kim, Chang-Hwoi; Park, Joo-Hyun; Lee, Dong-young; Koo, In-Soo
2005-12-01
In this paper, the design concept of the smart type motor operator valve for nuclear power plant was described. The development objective of the smart valve is to achieve superior accuracy, long-term reliability, and ease of use. In this reasons, developed smart valve has fieldbus communication such as deviceNet and Profibus-DP, auto-tuning PID controller, self-diagnostics, and on-line calibration capabilities. And also, to achieve pressure, temperature, and flow control with internal PID controller, the pressure sensor and transmitter were included in this valve. And, temperature and flow signal acquisition port was prepared. The developed smart valve will be performed equipment qualification test such as environment, EMI/EMC, and vibration in Korea Test Lab. And, the valve performance is tested in a test loop which is located in Seoul National University Lab. To apply nuclear power plant, the software is being developed according to software life cycle. The developed software is verified by independent software V and V team. It is expected that the smart valve can be applied to an existing NPPs for replacing or to a new nuclear power plants. The design and fabrication of smart valve is now being processed.
Hydraulic Evaluation of Culvert Valves at Eisenhower and Snell Locks, St. Lawrence Seaway
2015-06-01
ER D C/ CH L TR -1 5- 7 Hydraulic Evaluation of Culvert Valves at Eisenhower and Snell Locks, St. Lawrence Seaway Co as ta l a nd H...client/default. ERDC/CHL TR-15-7 June 2015 Hydraulic Evaluation of Culvert Valves at Eisenhower and Snell Locks, St. Lawrence Seaway...filling valve well of the Snell Lock’s south-wall culvert . The new vertical-frame valve operated at a slower rate than the double-skin-plate valve
DOE Office of Scientific and Technical Information (OSTI.GOV)
Posylkin, M.; Taylor, A.M.K.P.; Whitelaw, J.H.
The four-valve head of a VTEC engine was mounted on an open cylinder and the valves and fuel injection system operated as in the engine with a rotational speed of 1,200 rpm. Local measurements of droplet characteristics were obtained with a phase-Doppler velocimeter and iso-octane injected over 5 ms intervals, corresponding to 36 crank angle degrees, with manifold depression of 20 mbar. The results show that most of the fuel droplets were located close to the liner and on the side of the cylinder adjacent to the exhaust valves. In the plane of the measurement, 10 mm below TDC, themore » liquid flux diminished as the initiation of injection was advanced before opening of the inlet valves. With injection with the inlet valves closed, there were two waves of droplets, one from each of the two valves and separated by 60 deg CA and both with the Sauter mean diameter of about 120 {micro}m. With injection with the inlet valves open, most of the droplets emerged from the main inlet valve and with Sauter mean diameters of about 50 {micro}m, smaller than those of the unconfined spray.« less
Chivasso, Pierpaolo; Bruno, Vito D; Farid, Shakil; Malvindi, Pietro Giorgio; Modi, Amit; Benedetto, Umberto; Ciulli, Franco; Abu-Omar, Yasir; Caputo, Massimo; Angelini, Gianni D; Livesey, Steve; Vohra, Hunaid A
2018-04-01
An increasing number of octogenarians are referred to undergo mitral valve surgery for degenerative disease, and percutaneous approaches are being increasingly used in this subgroup of patients. We sought to determine the survival and its predictors after Mitral Valve Surgery in Octogenarians (MiSO) in a multicenter UK study of high-volume specialized centers. Pooled data from 3 centers were collected retrospectively. To identify the predictors of short-term composite outcome of 30 days mortality, acute kidney injury, and cerebrovascular accident, a multivariable logistic regression model was developed. Multiple Cox regression analysis was performed for late mortality. Kaplan-Meier curves were generated for long-term survival in various subsets of patients. Receiver operating characteristic analysis was done to determine the predictive power of the logistic European System for Cardiac Operative Risk Evaluation. A total of 247 patients were included in the study. The median follow-up was 2.9 years (minimum 0, maximum 14 years). A total of 150 patients (60.7%) underwent mitral valve repair, and 97 patients (39.3%) underwent mitral valve replacement. Apart from redo cardiac surgery (mitral valve repair 6 [4%] vs mitral valve replacement 11 [11.3%], P = .04) and preoperative atrial fibrillation (mitral valve repair 79 [52.6%] vs mitral valve replacement 34 [35.1%], P < .01), there was no significant difference in terms of any other preoperative characteristics between the 2 groups. Patient operative risk, as estimated by logistic European System for Cardiac Operative Risk Evaluation, was lower in the mitral valve repair group (10.2 ± 11.8 vs 13.7 ± 15.2 in mitral valve replacement; P = .07). No difference was found between groups for duration of cardiopulmonary bypass and aortic crossclamp times. The 30-day mortality for the whole cohort was 13.8% (mitral valve repair 4.7% vs mitral valve replacement 18.6%; P < .01). No differences were found in terms of postoperative cerebrovascular accident (2% vs 3.1%; P = .9), acute kidney injury requiring dialysis (6.7% vs 13.4%; P = .12), and superficial or deep sternal wound infection (10% vs 16.5%, P = .17; 2% vs 3.1%, P = .67, respectively). The final multiple regression model for short-term composite outcome included previous cardiac surgery (odds ratio [OR], 4.47; 95% confidence interval [CI], 1.37-17.46; P = .02), intra-aortic balloon pump use (OR, 4.77; 95% CI, 1.67-15.79; P < .01), and mitral valve replacement (OR, 7.7; 95% CI, 4.04-14.9; P < .01). Overall survival for the entire cohort at 1, 5, and 10 years was 82.4%, 63.7%, and 45.5% (mitral valve repair vs mitral valve replacement: 89.9% vs 70.7% at 1 year, 69.6% vs 54% at 5 years, and 51.8% vs 35.5% at 10 years; P = .0005). Cox proportional hazard model results showed mitral valve replacement (hazard ratio, 1.88; 95% CI, 1.22-2.89; P < .01) and intra-aortic balloon pump use (hazard ratio, 2.54; 95% CI, 1.26-5.13; P < .01) to be independent predictor factors affecting long-term survival. Logistic European System for Cardiac Operative Risk Evaluation did not perform well in predicting early mortality (area under the curve, 0.57%). In octogenarians, mitral valve repair for degenerative disease is associated with good survival and remains the gold standard, whereas mitral valve replacement is still associated with significant mortality. Logistic European System for Cardiac Operative Risk Evaluation was unable to predict early mortality in our cohort of patients. Larger international multicenter registries are required to optimize the decision-making process in such a high-risk subgroup. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Left atrial isolation associated with mitral valve operations.
Graffigna, A; Pagani, F; Minzioni, G; Salerno, J; Viganò, M
1992-12-01
Surgical isolation of the left atrium was performed for the treatment of chronic atrial fibrillation secondary to valvular disease in 100 patients who underwent mitral valve operations. From May 1989 to September 1991, 62 patients underwent mitral valve operations (group I); 19, mitral valve operations and DeVega tricuspid annuloplasty (group II); 15, mitral and aortic operations (group III); and 4, mitral and aortic operations and DeVega tricuspid annuloplasty (group IV). Left atrial isolation was performed, prolonging the usual left paraseptal atriotomy toward the left fibrous trigone anteriorly and the posteromedial commissure posteriorly. The incision was conducted a few millimeters apart from the mitral valve annulus, and cryolesions were placed at the edges to ensure complete electrophysiological isolation of the left atrium. Operative mortality accounted for 3 patients (3%). In 79 patients (81.4%) sinus rhythm recovered and persisted until discharge from the hospital. No differences were found between the groups (group I, 80.7%; group II, 68.5%; group III, 86.7%; group IV, 75%; p = not significant). Three late deaths (3.1%) were registered. Long-term results show persistence of sinus rhythm in 71% of group I, 61.2% of group II, 85.8% of group III, and 100% of group IV. The unique risk factor for late recurrence of atrial fibrillation was found to be preoperative atrial fibrillation longer than 6 months. Due to the satisfactory success rate in recovering sinus rhythm, we suggest performing left atrial isolation in patients with chronic atrial fibrillation undergoing valvular operations.
System and method for damping vibration in a drill string using a magnetorheological damper
Wassell, Mark Ellsworth; Burgess, Daniel E.; Barbely, Jason R.; Thompson, Fred Lamar
2018-05-22
A system for damping vibration in a drill string can include a magnetorheological fluid valve assembly having a supply of a magnetorheological fluid. A remanent magnetic field is induced in the valve during operation that can be used to provide the magnetic field for operating the valve so as to eliminate the need to energize the coils except temporarily when changing the amount of damping required. The current to be supplied to the coil for inducing a desired magnetic field in the valve is determined based on the limiting hysteresis curve of the valve and the history of the magnetization of the value using a binary search methodology. The history of the magnetization of the valve is expressed as a series of sets of current and it resulting magnetization at which the current experienced a reversal compared to prior values of the current.
Code of Federal Regulations, 2010 CFR
2010-07-01
... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure.../outlet Concentration Option § 63.3556 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2011 CFR
2011-07-01
... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure.../outlet Concentration Option § 63.3556 How do I establish the emission capture system and add-on control...
Code of Federal Regulations, 2013 CFR
2013-07-01
... system and add-on control device operating limits during the performance test? 63.3556 Section 63.3556... of key parameters of the valve operating system (e.g., solenoid valve operation, air pressure... Control Efficiency/outlet Concentration Option § 63.3556 How do I establish the emission capture system...
[LONG TERM FOLLOW-UP OF TRANSCATHETER SELF EXPANDABLE AORTIC VALVE IMPLANTATION].
Chen, Shmuel; Zenios, Vicky; Gilon, Dan; Planer, David; Beeri, Ronen; Lotan, Chaim; Danenberg, Haim D
2018-03-01
Aortic stenosis is the most common significant valvular disease in the western world. These patients are treated operatively unless they are at high operative risk or inoperable. During the last decade an alternative approach has evolved - transcatheter aortic valve implantation (TAVI). This method was shown to be at least as effective and safe as the operative one. However, very little data exists on long term follow-up (5 years and above), especially regarding valve durability and patient survival. To present a long term follow-up on patients who underwent transcutaneous self-expandable aortic valve implantation in our department between the years 2008-2011. In September 2008 the first CoreValve implantation was performed in Israel at Hadassah Medical Center. All records of patients who were transplanted between 9.2008 and 10.2011 were reviewed. The function of the valve early after the procedure was compared to its function at the end of the follow-up period. A total of 38 patients (out of 71) survived at least 54 months, of them, 19 have an echocardiography examination at the end of the follow-up period. In all patients the implanted valve was found to function well at the end of the follow-up period, without significant stenosis or paravalvular leak. In fact, in approximately half of these patients, the degree of paravalvular leak decreased during the follow-up period. On long term (5 years) follow-up of patients who were implanted with the self-expandable aortic valve (CoreValve), no deterioration of the valve was observed. In fact, in approximately half of the patients, a decrease in the severity of the paravalvular leak was demonstrated.
Note: A short-pulse high-intensity molecular beam valve based on a piezoelectric stack actuator
NASA Astrophysics Data System (ADS)
Abeysekera, Chamara; Joalland, Baptiste; Shi, Yuanyuan; Kamasah, Alexander; Oldham, James M.; Suits, Arthur G.
2014-11-01
Solenoid and piezoelectric disk valves, which are widely used to generate molecular beam pulses, still suffer from significant restrictions, such as pulse durations typically >50 μs, low repetition rates, and limited gas flows and operational times. Much of this arises owing to the limited forces these actuators can achieve. To overcome these limitations, we have developed a new pulsed valve based on a high-force piezoelectric stack actuator. We show here that operation with pulse durations as low as 20 μs and repetition rates up to 100 Hz can be easily achieved by operating the valve in conjunction with a commercial fast high-voltage switch. We outline our design and demonstrate its performance with molecular beam characterization via velocity map ion imaging.
Note: a short-pulse high-intensity molecular beam valve based on a piezoelectric stack actuator.
Abeysekera, Chamara; Joalland, Baptiste; Shi, Yuanyuan; Kamasah, Alexander; Oldham, James M; Suits, Arthur G
2014-11-01
Solenoid and piezoelectric disk valves, which are widely used to generate molecular beam pulses, still suffer from significant restrictions, such as pulse durations typically >50 μs, low repetition rates, and limited gas flows and operational times. Much of this arises owing to the limited forces these actuators can achieve. To overcome these limitations, we have developed a new pulsed valve based on a high-force piezoelectric stack actuator. We show here that operation with pulse durations as low as 20 μs and repetition rates up to 100 Hz can be easily achieved by operating the valve in conjunction with a commercial fast high-voltage switch. We outline our design and demonstrate its performance with molecular beam characterization via velocity map ion imaging.
Heat exchange equipment and valve design and operability improvement. NE-Volume 14
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singh, K.P; Niyogi, K.K.
1994-12-31
The papers contained in this volume were presented at the Maurice Holtz Memorial Sessions on Heat Exchanger Equipment and Valve Design and Operability Improvement, as part of the 1994 International Joint Power Generation Conference and Exhibition, October 2--6, in Phoenix, Arizona. These eight papers deal with two types of components--heat exchangers and valves, both of which are used in practically all sensors of the nuclear industry.
Long life valve design concepts
NASA Technical Reports Server (NTRS)
Jones, J. R.; Hall, A. H., Jr.
1975-01-01
Valve concept evaluation, final candidate selection, design, manufacture, and demonstration testing of a pneumatically actuated 10-inch hybrid poppet butterfly shutoff valve are presented. Conclusions and recommendations regarding those valve characteristics and features which would serve to guide in the formulation of future valve procurements are discussed. The pertinent design goals were temperature range of plus 200 to minus 423 F, valve inlet pressure 35 psia, actuation pressure 750 psia, main seal leakage 3 x 0.00001 sccs at 35 psia valve inlet pressure, and a storage and operating life of 10 years. The valve was designed to be compatible with RP-1, propane, LH2, LO2, He, and N2.
NASA Technical Reports Server (NTRS)
Addona, Brad; Eddleman, David
2015-01-01
A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.
Intracranial Pressure-Guided Shunt Valve Adjustments with the Miethke Sensor Reservoir.
Antes, Sebastian; Stadie, Axel; Müller, Simon; Linsler, Stefan; Breuskin, David; Oertel, Joachim
2018-01-01
Telemetric intracranial pressure (ICP) monitoring seems to be a promising therapy-supporting option in shunt-treated patients. Benefits become obvious when headaches are unspecific and clinical symptoms cannot be related to possible overdrainage or underdrainage. In this study, we evaluated a new telemetric device to individually adjust shunt valves according to ICP measurements. Between December 2015 and November 2016, 25 patients with suspected suboptimal shunt valve settings underwent insertion of a telemetric ICP sensor (Sensor Reservoir; Christoph Miethke, Potsdam, Germany). Over a 1-year period, a total of 183 telemetric ICP measurements and 85 shunt valve adjustments were carried out. Retrospective statistic analyses focused on valve adjustments, ICP values, and clinical outcomes. ICP-guided valve adjustments positively changed the clinical state in 18 out of 25 patients. Clinical improvement over time was associated with significant changes of the valve settings and ICP values. Interestingly, a therapeutically normalized ICP profile was not automatically associated with clinical improvement. The Sensor Reservoir is an important and valuable tool for shunt-treated patients suffering from drainage-related problems. The possibility to simultaneously recognize and solve shunt problems represents the decisive advantage. Nevertheless, measurements with the Sensor Reservoir did not allow for the determination of default valve settings or universal target ICP values. Copyright © 2017 Elsevier Inc. All rights reserved.
[Valvuloplasty with balloon catheter in biologic prosthesis. Reality or illusion].
Ledesma Velasco, M; Verdín Vázquez, R; Acosta Valdez, J L; Munayer Calderón, J; Salgado Escobar, J L; Arias Monroy, L; Flores Mendoza, J
1989-01-01
We performed catheter balloon valvuloplasty (CBV) on 8 stenotic operatively-excised bioprosthetic valves (2 Hancock and 6 Ionescu Shiley). Pathology of valves before CBV included degenerative changes: commissural fusion by mounds of calcific deposits (2 valves), fibrotic and focally calcified leaflets (7 valves) and stiff and thick valves (1 valve). Inflation of the balloon resulted in commissural splitting (2 valves), leaflet cracks and fractures (3 valves). Removal of the deflated balloon catheter was associated with debris dislodgement (3 valves). In one case the valve was unable to close with potential for acute regurgitation. Thus, CBV of bioprosthetic valves can split fused commissures by similar mechanisms as in native valves. CBV may fracture calcific deposits causing acute emboli. It can also disrupt the leaflets causing acute insufficiency. The findings suggest a limited role of CBV in the treatment of stenotic bioprosthetic valves in mitral and aortic position.
30. Engine controls and valve gear, looking aft on main ...
30. Engine controls and valve gear, looking aft on main (promenade) deck level. Threaded admission valve lift rods (two at immediate left of chronometer) permit adjustment of valve timing in lower and upper admission valves of cylinder (left rod controls lower valve, right rod upper valve). Valve rods are lifted by jaw-like "wipers" during operation. Exhaust valve lift rods and wipers are located to right of chronometer. Crank at extreme right drives valve wiper shaft when engaged to end of eccentric rod, shown under "Crank Indicator" dial. Pair of handles to immediate left of admission valve rods control condenser water valves; handles to right of exhaust valve rods control feedwater flow to boilers from pumps. Gauges indicate boiler pressure (left) and condenser vacuum (right); "Crank Indicator" on wall aids engineer in keeping engine crank off "dead-center" at stop so that engine may be easily restarted. - Steamboat TICONDEROGA, Shelburne Museum Route 7, Shelburne, Chittenden County, VT
46 CFR 115.704 - Breaking of safety valve seals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Breaking of safety valve seals. 115.704 Section 115.704... CERTIFICATION Repairs and Alterations § 115.704 Breaking of safety valve seals. The owner, managing operator, or master shall notify the cognizant OCMI as soon as practicable after the seal on a boiler safety valve on...
46 CFR 115.704 - Breaking of safety valve seals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Breaking of safety valve seals. 115.704 Section 115.704... CERTIFICATION Repairs and Alterations § 115.704 Breaking of safety valve seals. The owner, managing operator, or master shall notify the cognizant OCMI as soon as practicable after the seal on a boiler safety valve on...
46 CFR 78.47-38 - Valves and closing appliances.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 3 2010-10-01 2010-10-01 false Valves and closing appliances. 78.47-38 Section 78.47-38... Fire and Emergency Equipment, Etc. § 78.47-38 Valves and closing appliances. (a) All valves and closing appliances, or other mechanisms which may be required to be operated for damage control purposes in case of...
A timed solenoid injector for flow analysis.
Rothwell, S D; Woolf, A A
1985-05-01
Samples can be reproducibly injected into flow-streams by timed switching of a sample stream with a miniature solenoid valve and timer circuit. The device is simpler to assemble and use than the standard rotary valve and a direct comparison under the same operating conditions shows that the solenoid valve is an adequate replacement for the rotary valve.
AUTOMOTIVE DIESEL MAINTENANCE 2 UNIT IV, AUTOMATIC TRANSMISSIONS--HYDRAULICS (PART II).
ERIC Educational Resources Information Center
Human Engineering Inst., Cleveland, OH.
THIS MODULE OF A 25-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF VALVES UTILIZED IN HYDRAULIC TRANSMISSIONS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) REVIEWING FACTS ABOUT PUMPS, (2) USING VALVES FOR CONTROL, (3) TROUBLESHOOTING PROCEDURES ON RELIEF VALVES, (4) USING DIRECTIONAL CONTROL VALVES,…
40 CFR 264.1056 - Standards: Open-ended valves or lines.
Code of Federal Regulations, 2010 CFR
2010-07-01
... hazardous waste stream end is closed before the second valve is closed. (c) When a double block and bleed system is being used, the bleed valve or line may remain open during operations that require venting the...
NASA Technical Reports Server (NTRS)
Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)
2003-01-01
A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.
Nuclear-radiation-actuated valve. [Patent application; for increasing coolant flow to blanket
Christiansen, D.W.; Schively, D.P.
1982-01-19
The present invention relates to a breeder reactor blanket fuel assembly coolant system valve which increases coolant flow to the blanket fuel assembly to minimize long-term temperature increases caused by fission of fissile fuel created from fertile fuel through operation of the breeder reactor. The valve has a valve first part (such as a valve rod with piston) and a valve second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics. The valve's first part is positioned to receive nuclear radiation from the nuclear reactor's fuel region. The valve's second part is positioned so that its nuclear radiation induced swelling is different from that of the valve's first part. The valve's second part also is positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system.
NASA Technical Reports Server (NTRS)
Gonzalez, R.; Vandewalle, J.
1986-01-01
Redesigned actuator assembly weighs 50 percent less. Isolator valve operated by ac motor instead of usual dc solenoid. Valve weighs only 3 lb (1.4 kg). New valve functions with either two-phase or three-phase power. Developed for isolating fluids in propellant tanks, manifolds, and interconnecting lines of Space Shuttle reaction control and orbital maneuvering subsystems, valve suited to applications in which leakage must be kept to minimum at high pressure differences - in petroleum and chemical processing.
NASA Astrophysics Data System (ADS)
Pitton, Giuseppe; Quaini, Annalisa; Rozza, Gianluigi
2017-09-01
We focus on reducing the computational costs associated with the hydrodynamic stability of solutions of the incompressible Navier-Stokes equations for a Newtonian and viscous fluid in contraction-expansion channels. In particular, we are interested in studying steady bifurcations, occurring when non-unique stable solutions appear as physical and/or geometric control parameters are varied. The formulation of the stability problem requires solving an eigenvalue problem for a partial differential operator. An alternative to this approach is the direct simulation of the flow to characterize the asymptotic behavior of the solution. Both approaches can be extremely expensive in terms of computational time. We propose to apply Reduced Order Modeling (ROM) techniques to reduce the demanding computational costs associated with the detection of a type of steady bifurcations in fluid dynamics. The application that motivated the present study is the onset of asymmetries (i.e., symmetry breaking bifurcation) in blood flow through a regurgitant mitral valve, depending on the Reynolds number and the regurgitant mitral valve orifice shape.
Combined pressure regulator and shutoff valve
NASA Technical Reports Server (NTRS)
Koch, E. F. (Inventor)
1974-01-01
A remotely operable pressure regulator and shutoff valve particularly suited for achieving high resolution and flow control, and positive shutoff is described. The valve is characterized by a spring-loaded ball coaxially aligned with a fluid port to be sealed, a spring-loaded pintle extended through the port into engagement with the ball, for controlling the position, a spring-loaded diaphragm for controlling the position of the pintle, and an axially displaceable spring supported by a movable stop which, in turn, is repositioned by a selectively operable stepper motor. Thus, the pressure-response characteristics for the valve can be varied through a selective repositioning of the stop.
Gadhinglajkar, Shrinivas; Sreedhar, Rupa; Karunakaran, Jayakumar; Misra, Manoranjan; Somasundaram, Ganesh; Mathew, Thomas
2010-01-01
A pacing system infection may lead to infective endocarditis and systemic sepsis. Tricuspid valve surgery may be required if the valve is severely damaged in the process of endocarditis. Although, cardiopulmonary bypass is the safe choice for performing right-heart procedures, it may carry risk of inducing systemic inflammatory response and multi-organ dysfunction. Some studies have advocated TV surgery without institution of CPB. We report tricuspid valve excision using the off-pump inflow occlusion technique in a 68-year-old man. We also describe role of intra-operative TEE as a monitoring tool at different stages of the surgical procedure.
Tricuspid valve replacement with mechanical prostheses: Short and long-term outcomes.
Rossello, Xavier; Muñoz-Guijosa, Christian; Mena, Elisabet; Camprecios, Marta; Mendez, Ana B; Borras, Xavier; Padro, Josep M
2017-09-01
Tricuspid valve replacement has been associated with high mortality and poor long-term outcomes. We report the preoperative risk factors associated with short and long-term outcomes following tricuspid valve replacement with mechanical prostheses. In 62 patients who underwent mechanical tricuspid valve replacement, clinical, laboratory, and echocardiographic findings were analyzed using both univariate and multivariate analyses to describe operative and long-term mortality. In our population (mean age 59 ± 9.7 years, 82.3% female), most common causes of tricuspid valve disease were rheumatic fever (69.4%) and functional regurgitation (19.4%). Operative and long-term mortality were 17.7 and 33.9%, respectively. Age, diabetes mellitus, and coronary artery disease were independently associated with increased long-term mortality. New York Heart Association (NYHA) class and right heart failure symptoms significantly improved during follow-up. In this series of mechanical tricuspid valve replacements in patients with predominately rheumatic heart disease, operative and long-term mortality were increased; however, survivors had significant improvement in their NYHA class and freedom from right heart failure symptoms. Three preoperative factors (age, diabetes mellitus, and coronary artery disease) were independently associated with long-term mortality. © 2017 Wiley Periodicals, Inc.
Contamination avoidance devices for poppet type shutoff valves
NASA Technical Reports Server (NTRS)
Endicott, D. L.
1972-01-01
The technology required to provide acceptable contamination damage avoidance characteristics for poppet type shutoff valves is discussed. Evaluation of the contamination avoidance characteristics of the basic 1T32095 propellant shutoff valve, the cycle life performance of these valves in an uncontaminated environment, and the effectiveness of various auxiliary contamination avoidance devices when used in conjunction with these poppet type valves are included. In addition, a secondary objective is to evaluate two methods of monitoring the performance of the test valves during actual operations using acoustical monitoring instrumentation.
Asada, Dai; Ikeda, Kazuyuki; Yamagishi, Masaaki
2017-04-01
There are a few reports of successful replacement of the left-sided systemic tricuspid valve with a mechanical valve in small infants with congenitally corrected transposition of the great arteries having Ebstein's anomaly. Tricuspid valve replacement is the preferred option when pulmonary artery banding, performed as a prelude to performing the double-switch operation, is not feasible because of severe heart failure caused by tricuspid regurgitation.
Prediction and Reduction of Noise in Pneumatic Bleed Valves
NASA Astrophysics Data System (ADS)
Taghavi Nezhad, Shervin
This study investigates numerically the fluid mechanics and acoustics of pneumatic bleed valves used in turbofan engines. The goal is to characterized the fundamental processes of noise generation and devise strategies for noise reduction. Three different methods are employed for both analysis and redesign of the bleed valve to reduce noise. The bleed valve noise problem is carefully divided into multiple smaller problems. For large separations and tonal noises, the unsteady Reynolds-Averaged Navier-Stokes (URANS) method is utilized. This method is also applied in the re-designing of the bleed valve geometry. For the bleed valve muffler, which is comprised of perforated plates and a honeycomb, a Reynolds-Averaged Navier-Stokes (RANS) method combined with a simplified acoustic analogy is used. The original muffler design is modified to improve noise attenuation. Finally, for sound scattering through perforated plates, a fully implicit linearized Euler solver is developed. The problem of sound interaction with perforated plates is studied from two perspectives. In the first study the effect of high--speed mean flow is considered and it is shown that at Strouhal numbers of around 0.2-0.25 there is an increase in transmitted incident sound. In the second part, the interaction of holes in two--dimensional perforated plates is investigated using three different configurations. The study demonstrates that the hole interaction has a significant impact on sound attenuation, especially at high frequencies.
46 CFR 196.30-20 - Breaking of safety valve seal.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Breaking of safety valve seal. 196.30-20 Section 196.30... OPERATIONS Reports of Accidents, Repairs, and Unsafe Equipment § 196.30-20 Breaking of safety valve seal. (a) If at any time it is necessary to break the seal on a safety valve for any purpose, the Chief...
46 CFR 196.30-20 - Breaking of safety valve seal.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Breaking of safety valve seal. 196.30-20 Section 196.30... OPERATIONS Reports of Accidents, Repairs, and Unsafe Equipment § 196.30-20 Breaking of safety valve seal. (a) If at any time it is necessary to break the seal on a safety valve for any purpose, the Chief...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2014 CFR
2014-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2013 CFR
2013-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
40 CFR 60.483-2 - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
... valves in gas/vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0... Industry for which Construction, Reconstruction, or Modification Commenced After January 5, 1981, and on or... periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2011 CFR
2011-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2012 CFR
2012-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2013 CFR
2013-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2011 CFR
2011-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2014 CFR
2014-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2012 CFR
2012-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2010 CFR
2010-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 264.1061 Section... Emission Standards for Equipment Leaks § 264.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator subject to...
Code of Federal Regulations, 2013 CFR
2013-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Code of Federal Regulations, 2014 CFR
2014-07-01
... gas/vapor service or in light liquid service: percentage of valves allowed to leak. 265.1061 Section... FACILITIES Air Emission Standards for Equipment Leaks § 265.1061 Alternative standards for valves in gas/vapor service or in light liquid service: percentage of valves allowed to leak. (a) An owner or operator...
Note: A short-pulse high-intensity molecular beam valve based on a piezoelectric stack actuator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abeysekera, Chamara; Joalland, Baptiste; Shi, Yuanyuan
2014-11-15
Solenoid and piezoelectric disk valves, which are widely used to generate molecular beam pulses, still suffer from significant restrictions, such as pulse durations typically >50 μs, low repetition rates, and limited gas flows and operational times. Much of this arises owing to the limited forces these actuators can achieve. To overcome these limitations, we have developed a new pulsed valve based on a high-force piezoelectric stack actuator. We show here that operation with pulse durations as low as 20 μs and repetition rates up to 100 Hz can be easily achieved by operating the valve in conjunction with a commercialmore » fast high-voltage switch. We outline our design and demonstrate its performance with molecular beam characterization via velocity map ion imaging.« less
Combustion mode switching with a turbocharged/supercharged engine
Mond, Alan; Jiang, Li
2015-09-22
A method for switching between low- and high-dilution combustion modes in an internal combustion engine having an intake passage with an exhaust-driven turbocharger, a crankshaft-driven positive displacement supercharger downstream of the turbocharger and having variable boost controllable with a supercharger bypass valve, and a throttle valve downstream of the supercharger. The current combustion mode and mass air flow are determined. A switch to the target combustion mode is commanded when an operating condition falls within a range of predetermined operating conditions. A target mass air flow to achieve a target air-fuel ratio corresponding to the current operating condition and the target combustion mode is determined. The degree of opening of the supercharger bypass valve and the throttle valve are controlled to achieve the target mass air flow. The amount of residual exhaust gas is manipulated.
Intraoperative echocardiographic detection of regurgitant jets after valve replacement
NASA Technical Reports Server (NTRS)
Morehead, A. J.; Firstenberg, M. S.; Shiota, T.; Qin, J.; Armstrong, G.; Cosgrove, D. M. 3rd; Thomas, J. D.
2000-01-01
BACKGROUND: Paravalvular jets, documented by intraoperative transesophageal echocardiography, have prompted immediate valve explantation by others, yet the significance of these jets is unknown. METHODS: Twenty-seven patients had intraoperative transesophageal two-dimensional color Doppler echocardiography, performed to assess the number and area of regurgitant jets after valve replacement, before and after protamine. Patients were grouped by first time versus redo operation, valve position and type. RESULTS: Before protamine, 55 jets were identified (2.04+/-1.4 per patient) versus 29 jets after (1.07+/-1.2 per patient, p = 0.0002). Total jet area improved from 2.0+/-2.2 cm2 to 0.86+/-1.7 cm2 with protamine (p<0.0001). In all patients jet area decreased (average decrease, 70.7%+/-27.0%). First time and redo operations had similar improvements in jet number and area (both p>0.6). Furthermore, mitral and mechanical valves each had more jets and overall greater jet area when compared to aortic and tissue valves, respectively. CONCLUSIONS: Following valve replacement, multiple jets are detected by intraoperative transesophageal echocardiography. They are more common and larger in the mitral position and with mechanical valves. Improvement occurs with reversal of anticoagulation.
A Study of Discharge Coefficient in Bileaflet Valves
2001-10-25
Granados J. Garcia MA. Luque I. Concha M. “Conservative operation for mitral stenosis with densely fibrosed or partially calcified valves. An eight...for aortic valves, whereas a lower value (around 0.7) has been proposed for valves mounted in the mitralic position, on account of the larger upstream...section; in the mitral position, then, a valve will have a smaller discharge coefficient (or Aeff/A ratio) than in the aortic position. Using dC =1
Fail-safe bidirectional valve driver
NASA Technical Reports Server (NTRS)
Fujimoto, H.
1974-01-01
Cross-coupled diodes are added to commonly used bidirectional valve driver circuit to protect circuit and power supply. Circuit may be used in systems requiring fail-safe bidirectional valve operation, particularly in chemical- and petroleum-processing control systems and computer-controlled hydraulic or pneumatic systems.
Liquid-fuel valve with precise throttling control
NASA Technical Reports Server (NTRS)
Mcdougal, A. R.; Porter, R. N.; Riebling, R. W.
1971-01-01
Prototype liquid-fuel valve performs on-off and throttling functions in vacuum without component cold-welding or excessive leakage. Valve design enables simple and rapid disassembly and parts replacement and operates with short working stroke, providing maximum throttling sensitivity commensurate with good control.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Fuel valves. 121.235 Section 121.235 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Fuel valves. 121.235 Section 121.235 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Fuel valves. 121.235 Section 121.235 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fuel valves. 121.235 Section 121.235 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Fuel valves. 121.235 Section 121.235 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.235 Fuel valves. Each fuel...
Dual-Use Partnership Addresses Performance Problems with "Y" Pattern Control Valves
NASA Technical Reports Server (NTRS)
Bailey, John W.
2004-01-01
A Dual-Use Cooperative Agreement between the Propulsion Test Directorate (PTD) at Stennis Space Center (SSC) and Oceaneering Reflange, Inc. of Houston, TX has produced an improved 'Y' pattern split-body control valve for use in the propulsion test facilities at Stennis Space Center. The split-body, or clamped bonnet technology, provides for a 'cleaner' valve design featuring enhanced performance and increased flow capacity with extended life expectancy. Other points addressed by the partnership include size, weight and costs. Overall size and weight of each valve will be reduced by 50% compared to valves currently in use at SSC. An initial procurement of two 10 inch valves will result in an overall cost reduction of 15% or approximately $50,000 per valve.
NASA Technical Reports Server (NTRS)
Perkins, Gerald S. (Inventor)
1979-01-01
A check valve which closes more rapidly to prevent wearing of the valve seat and of the valve member that seals thereagainst, including a solenoid or other actuator that aids the normal spring to quickly close the valve at approximately the time when downpath fluid flow would stop, the actuator then being deenergized. The control circuit that operates the actuator can include a pair of pressure sensors sensing pressure both upstream and downstream from the valve seat. Where the valve is utilized to control flow to or from a piston pump, energization of the actuator can be controlled by sensing when the pump piston reaches its extreme of travel.
Control rod drive hydraulic system
Ose, Richard A.
1992-01-01
A hydraulic system for a control rod drive (CRD) includes a variable output-pressure CR pump operable in a charging mode for providing pressurized fluid at a charging pressure, and in a normal mode for providing the pressurized fluid at a purge pressure, less than the charging pressure. Charging and purge lines are disposed in parallel flow between the CRD pump and the CRD. A hydraulic control unit is disposed in flow communication in the charging line and includes a scram accumulator. An isolation valve is provided in the charging line between the CRD pump and the scram accumulator. A controller is operatively connected to the CRD pump and the isolation valve and is effective for opening the isolation valve and operating the CRD pump in a charging mode for charging the scram accumulator, and closing the isolation valve and operating the CRD pump in a normal mode for providing to the CRD through the purge line the pressurized fluid at a purge pressure lower than the charging pressure.
Internal combustion engine with rotary valve assembly having variable intake valve timing
Hansen, Craig N.; Cross, Paul C.
1995-01-01
An internal combustion engine has rotary valves associated with movable shutters operable to vary the closing of intake air/fuel port sections to obtain peak volumetric efficiency over the entire range of speed of the engine. The shutters are moved automatically by a control mechanism that is responsive to the RPM of the engine. A foot-operated lever associated with the control mechanism is also used to move the shutters between their open and closed positions.
An Apparatus for Measuring Rates of Discharge of a Fuel-Injection System
NASA Technical Reports Server (NTRS)
Dutee, Francis J
1941-01-01
A portable apparatus for rapidly determining rates of discharge of a fuel-injection system is described. Satisfactory operation of this apparatus with injection-pump speeds up to 2400 r.p.m was obtained. Rate-of-discharge tests were made with several cam-plunger-valve injection systems with long injection tubes. A check valve designed to reduce secondary discharges was tested. This check valve was operated with injection-pump speeds up to 2400 r.p.m without the occurrence of large secondary discharges.
Triple valve surgery: a 25-year experience.
Yilmaz, Mustafa; Ozkan, Murat; Böke, Erkmen
2004-09-01
Surgical treatment of rheumatic valvular disease still constitutes a significant number of cardiac operations in developing countries. Despite improvements in myocardial protection and cardiopulmonary bypass techniques, triple valve operations (aortic, mitral and tricuspid valves) are still challenging because of longer duration of cardiopulmonary bypass and higher degree of myocardial decompensation. This study was instituted in order to assess results of triple valve surgery. Between 1977 and 2002, 34 patients underwent triple valve surgery in our clinic by the same surgeon (EB). Eleven patients underwent triple valve replacement (32.4%) and 23 underwent tricuspid valve annuloplasty with aortic and mitral valve replacements (67.6%). There was no significant difference between the two groups of patients who underwent triple valve replacement and aortic and mitral valve replacement with tricuspid valve annuloplasty. There were 4 hospital deaths (11.8%) occurring within 30 days. The duration of follow-up for 30 survivors ranged from 6 to 202 months (mean 97 months). The actuarial survival rates were 85%, 72%, and 48% at 5, 10, and 15 years respectively. Actuarial freedom from reoperation rates at 5, 10, and 15 years was 86.3%, 71.9%, and 51.2%, respectively. Freedom from cerebral thromboembolism and anticoagulation-related hemorrhage rates, expressed in actuarial terms was 75.9% and 62.9% at 5 and 10 years. Major cerebral complications occurred in 10 of the 30 patients. We prefer replacing, if repairing is not possible, the tricuspid valve, with a bileaflet mechanical prosthesis in a patient with valve replacement of the left heart who will be anticoagulated in order to avoid unfavorable properties of bioprosthesis like degeneration and of old generation mechanical prosthesis like thrombosis and poor hemodynamic function. In recent years, results of triple valve surgery either with tricuspid valve conservation or valve replacement in suitable cases have become encouraging with improvements in surgical techniques and myocardial preservation methods.
FLUID PRESSURE AND CAM OPERATED VACUUM VALVE
Batzer, T.H.
1963-11-26
An ultra-high vacuum valve that is bakable, reusable, and capable of being quickly opened and closed is described. A translationally movable valve gate having an annular ridge is adapted to contact an annular soft metal gasket disposed at the valve seat such that the soft metal gasket extends beyond the annular ridge on all sides. The valve gate is closed, by first laterally aligning the valve gate with the valve seat and then bringing the valve gate and valve seat into seating contact by the translational movement of a ramp-like wedging means that engages similar ramp-like stractures at the base of the valve gate to force the valve gate into essentially pressureless contact with the annular soft metal gasket. This gasket is then pressurized from beneath by a fluid thereby effecting a vacuura tight seal between the gasket and the ridge. (AEC)
Dysfunction of an On-X Heart Valve by Pannus.
Abad, Cipriano; Urso, Stefano; Gomez, Elsa; De la Vega, Maria
2016-09-01
A 68-year-old woman with a history of previous double-valve replacement with On-X mechanical heart valves presented with clinical, echocardiographic and cardiac catheterization signs of obstruction of the On-X tricuspid heart valve prosthesis. The patient was successfully reoperated, but at surgery the valve was seen to be invaded by an abnormal overgrowth of pannus that blocked one of the leaflets. A small amount of non-obstructive fresh thrombus was also observed. The valve was successfully replaced with a biological heart valve prosthesis. The patient was discharged home, and is doing well four months after the operation, when echocardiography demonstrated normal function in the tricuspid valve. The present case represents the first ever report of pannus formation and subsequent dysfunction in an On-X heart valve, and also the first case of tricuspid valve malfunction and obstruction using this type of heart valve substitute.
Valve-sparing aortic root replacement in bicuspid aortic valves: a reasonable option?
Aicher, Diana; Langer, Frank; Kissinger, Anke; Lausberg, Henning; Fries, Roland; Schäfers, Hans-Joachim
2004-11-01
Aortic dilatation occurs in many patients with bicuspid aortic valves. We have added root replacement using the remodeling technique originally designed for tricuspid aortic valves to bicuspid aortic valve repair for treatment of the dilated root. We compared the results of remodeling in bicuspid aortic valves with those in tricuspid aortic valves. From October 1995 through January 2004, 60 patients underwent root remodeling for bicuspid aortic valves (group A), and 130 patients underwent root remodeling for tricuspid aortic valves (group B). Correction of cusp prolapse was more often performed in group A (group A, 50/60; group B, 47/130; P < .0001). Transthoracic echocardiography was performed at 1 week, 6 and 12 months, and every year thereafter. Cumulative follow-up was 527 patient-years (mean, 2.9 +/- 2 years). No patient died in group A. Hospital mortality in group B was 5% (5/100; 95% confidence interval,1.6%-11.3%) after elective operations and 10% (3/30; 95% confidence interval, 2.1%-26.5%) after emergency operations. Mean systolic gradients were identical at 1 year (group A, 4.8 +/- 2.1 mm Hg; group B, 4.0 +/- 2 mm Hg) and 5 years (group A, 4.5 +/- 2.3 mm Hg; group B, 3.9 +/- 2.2 mm Hg). Freedom from aortic regurgitation of grade 2 or higher at 5 years was 96% in group A and 83% in group B ( P = .07), and freedom from reoperation at 5 years was 98% in group A and 98% in group B ( P = .73). Valve-sparing aortic replacement with root remodeling can be applied to aortic dilatation and a regurgitant bicuspid aortic valve. Hemodynamic function and valve stability of a repaired bicuspid aortic valve are comparable with those seen in cases of tricuspid anatomy.
Hydraulic actuator for an electric circuit breaker
Imam, I.
1983-05-17
This actuator comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit breaker opening operation. The breaker-opening space and the breaker-closing space are connected by an impeded flow passage. A pilot valve opens to allow the pressurized liquid in the breaker-closing space to flow to a back chamber of a normally closed main valve to cause the main valve to be opened during a circuit breaker opening operation to release the pressurized liquid from the breaker-closing space. An impeded passage affords communication between the back chamber and a sump located on the opposite side of the main valve from the back chamber. The pilot valve and impeded passage allow rapid opening of the main valve with pressurized liquid from the breaker closing side of the piston. 3 figs.
Hydraulic actuator for an electric circuit breaker
Imam, Imdad [Colonie, NY
1983-01-01
This actuator comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit breaker opening operation. The breaker-opening space and the breaker-closing space are connected by an impeded flow passage. A pilot valve opens to allow the pressurized liquid in the breaker-closing space to flow to a back chamber of a normally closed main valve to cause the main valve to be opened during a circuit breaker opening operation to release the pressurized liquid from the breaker-closing space. An impeded passage affords communication between the back chamber and a sump located on the opposite side of the main valve from the back chamber. The pilot valve and impeded passage allow rapid opening of the main valve with pressurized liquid from the breaker closing side of the piston.
Double-reed exhaust valve engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bennett, Charles L.
An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.
Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A
2017-06-01
A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.
NASA Technical Reports Server (NTRS)
Leggett, Nickolaus
1990-01-01
The ambient natural vacuum of space is proposed as a basis for electron valves. Each valve is an electron controlling structure similiar to a vacuum tube that is operated without a vacuum sustaining envelope. The natural vacuum electron valves discussed offer a viable substitute for solid state devices. The natural vacuum valve is highly resistant to ionizing radiation, system generated electromagnetic pulse, current transients, and direct exposure to space conditions.
46 CFR 35.35-10 - Closing of freeing-ports, scuppers, and sea valves-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Closing of freeing-ports, scuppers, and sea valves-TB... OPERATIONS Cargo Handling § 35.35-10 Closing of freeing-ports, scuppers, and sea valves—TB/ALL. The person in... no circumstances may sea valves be secured by locks, the valves must be closed, and lashed or sealed...
46 CFR 35.35-10 - Closing of freeing-ports, scuppers, and sea valves-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Closing of freeing-ports, scuppers, and sea valves-TB... OPERATIONS Cargo Handling § 35.35-10 Closing of freeing-ports, scuppers, and sea valves—TB/ALL. The person in... no circumstances may sea valves be secured by locks, the valves must be closed, and lashed or sealed...
Streamline coal slurry letdown valve
Platt, Robert J.; Shadbolt, Edward A.
1983-01-01
A streamlined coal slurry letdown valve is featured which has a two-piece throat comprised of a seat and seat retainer. The two-piece design allows for easy assembly and disassembly of the valve. A novel cage holds the two-piece throat together during the high pressure letdown. The coal slurry letdown valve has long operating life as a result of its streamlined and erosion-resistance surfaces.
Streamline coal slurry letdown valve
Platt, R.J.; Shadbolt, E.A.
1983-11-08
A streamlined coal slurry letdown valve is featured which has a two-piece throat comprised of a seat and seat retainer. The two-piece design allows for easy assembly and disassembly of the valve. A novel cage holds the two-piece throat together during the high pressure letdown. The coal slurry letdown valve has long operating life as a result of its streamlined and erosion-resistance surfaces. 5 figs.
Review of Congenital Mitral Valve Stenosis: Analysis, Repair Techniques and Outcomes.
Baird, Christopher W; Marx, Gerald R; Borisuk, Michele; Emani, Sitram; del Nido, Pedro J
2015-06-01
The spectrum of congenital mitral valve stenosis (MS) consists of a complex of defects that result in obstruction to left ventricular inflow. This spectrum includes patients with underdeveloped left heart structures (Fig. 1) to those with isolated congenital MS. The specific mitral valve defects can further be divided into categories based on the relationship to the mitral valve annulus including valvar, supravalvar and subvalvar components. Clinically, these patients present based on the degree of obstruction, associated mitral regurgitation, secondary pulmonary hypertension, associated lung disease and/or associated cardiac lesions. There are a number of factors that contribute to the successful outcomes in these patients including pre-operative imaging, aggressive surgical techniques and peri-operative management.
Transforming Growth Factor Beta-2 Mutations in Barlow's Disease and Aortic Dilatation.
Disha, Kushtrim; Schulz, Solveig; Kuntze, Thomas; Girdauskas, Evaldas
2017-07-01
We report on a patient operated on for degenerative myxomatous mitral and tricuspid valve disease (Barlow's disease) and aortic root dilatation. A valve repair operation and the postoperative course were uneventful. Multigenerational genetic analyses revealed two different mutations in the transforming growth factor beta-2 gene in the same patient. The two mutations in different exons were inherited from both parents each. None of the parents presented with either valve dysfunction or aortic root dilatation. This rare case illustrates potentially common genetic and signaling pathways of concomitant myxomatous valve disease and aortic root dilatation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Urbanski, Paul P.; Lenos, Aristidis; Irimie, Vadim; Bougioukakis, Petros; Zacher, Michael; Diegeler, Anno
2016-01-01
OBJECTIVES The aim of the study was to evaluate operative and long-term results after surgery of acute aortic dissection involving the root, in which the proximal repair consisted of curative resection of all dissected aortic sinuses and was performed using either valve-sparing root repair or complete root replacement with a valve conduit. METHODS Between August 2002 and March 2013, 162 consecutive patients (mean age 63 ± 14 years) underwent surgery for acute type A aortic dissection. Eighty-six patients with an involvement of the aortic root underwent curative surgery of the proximal aorta consisting of valve-sparing root repair (n = 54, 62.8%) or complete valve and root replacement using composite valve grafts (n = 32, 37.2%). In patients with root repair, all dissected aortic walls were resected and root remodelling using the single patch technique (n = 53) or root repair with valve reimplantation (n = 1) was performed without the use of any glue. All perioperative data were collected prospectively and retrospective statistical examination was performed using univariate and multivariate analyses. RESULTS The mean follow-up was 5.2 ± 3.5 years for all patients (range 0–12 years) and 6.1 ± 3.3 years for survivors. The 30-day mortality rate was 5.8% (5 patients), being considerably lower in the repair sub-cohort (1.9 vs 12.5%). The estimated survival rate at 5 and 10 years was 80.0 ± 4.5 and 69.1 ± 6.7%, respectively. No patient required reoperation on the proximal aorta and/or aortic valve during the follow-up time and there were only two valve-related events (both embolic, one in each group). Among those patients with repaired valves, the last echocardiography available showed no insufficiency in 40 and an irrelevant insufficiency (1+) in 14. CONCLUSIONS Curative repair of the proximal aorta in acute dissection involving the root provides favourable operative and long-term outcome with very low risk of aortic complications and/or reoperations, regardless if a valve-sparing procedure or replacement with a valve conduit is used. Valve-sparing surgery is frequently suitable, providing excellent outcome and very high durability. PMID:26848190
42 CFR 84.84 - Hand-operated valves; minimum requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...
42 CFR 84.84 - Hand-operated valves; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...
42 CFR 84.84 - Hand-operated valves; minimum requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...
42 CFR 84.84 - Hand-operated valves; minimum requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...
42 CFR 84.84 - Hand-operated valves; minimum requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...
Baraki, Hassina; Al Ahmad, Ammar; Sarikouch, Samir; Koigeldiev, Nurbol; Khaladj, Nawid; Hagl, Christian; Pichlmaier, Maximillian; Haverich, Axel; Shrestha, Malakh
2010-05-01
Composite replacement is the standard treatment for the repair of aortic aneurysm with aortic valve pathology. With improved long-term durability and no requirement for long-term anticoagulation, tissue-valved conduits have become increasingly popular. Herein are reported the results achieved with 50 consecutive 'Bentall' operations, using the first commercially available prefabricated stentless tissue-valved conduit (Vascutek BioValsalva). Between September 2007 and September 2009, a total of 50 patients (10 females, 40 males; mean age 65 +/- 7 years) received a BioValsalva conduit. Concomitant procedures included coronary artery bypass grafting (CABG; n = 15), other valve (n = 5), and aortic arch replacement with circulatory arrest (n = 20; three of these had an additional frozen elephant trunk). Four of the procedures were re-operations. A six-month follow up with echocardiography and clinical examination was completed in 25 patients. The 30-day mortality was 8% (4/50). Three of these patients underwent concomitant procedures. The cardiopulmonary bypass (CPB) and cross-clamp times were 178 +/- 30 min and 106 +/- 7 min, respectively. The triple-layered vascular graft proved to be hemostatic, without suture-line bleeding. Both, the initial and follow up echocardiography showed no valvular insufficiency, with a mean gradient of 13 +/- 5 mmHg. All patients were in NYHA class I-II. The BioValsalva prefabricated tissue-valved conduit showed very good early results. The ischemic time required to construct a 'home-made' stentless tissue-valved conduit was eliminated, thus reducing the cross-clamp time. The conduit also offered the hemodynamic advantages of a stentless valve.
Inkjet 3D printed check microvalve
NASA Astrophysics Data System (ADS)
Walczak, Rafał; Adamski, Krzysztof; Lizanets, Danylo
2017-04-01
3D printing enables fast and relatively easy fabrication of various microfluidic structures including microvalves. A check microvalve is the simplest valve enabling control of the fluid flow in microchannels. Proper operation of the check valve is ensured by a movable element that tightens the valve seat during backward flow and enables free flow for forward pressure. Thus, knowledge of the mechanical properties of the movable element is crucial for optimal design and operation of the valve. In this paper, we present for the first time the results of investigations on basic mechanical properties of the building material used in multijet 3D printing. Specified mechanical properties were used in the design and fabrication of two types of check microvalve—with deflecting or hinge-fixed microflap—with 200 µm and 300 µm thickness. Results of numerical simulation and experimental data of the microflap deflection were obtained and compared. The valves were successfully 3D printed and characterised. Opening/closing characteristics of the microvalve for forward and backward pressures were determined. Thus, proper operation of the check microvalve so developed was confirmed.
75 FR 27668 - Airworthiness Directives; Fokker Services B.V. Model F.28 Mark 0070 and 0100 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-18
... cause of the MLG extension problem was the (partially) blocked hydraulic return line from the MLG selector valve by pieces of hard plastic. These were identified as parts of the poppet seat of PBSOV... problem was the (partially) blocked hydraulic return line from the MLG selector valve by pieces of hard...
75 FR 66649 - Airworthiness Directives; Fokker Services B.V. Model F.28 Mark 0070 and 0100 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-29
... investigation revealed that the cause of the MLG extension problem was the (partially) blocked hydraulic return line from the MLG selector valve by pieces of hard plastic. These were identified as parts of the... extension problem was the (partially) blocked hydraulic return line from the MLG selector valve by pieces of...
Dynamic water behaviour due to one trapped air pocket in a laboratory pipeline apparatus
NASA Astrophysics Data System (ADS)
Bergant, A.; Karadžić, U.; Tijsseling, A.
2016-11-01
Trapped air pockets may cause severe operational problems in hydropower and water supply systems. A locally isolated air pocket creates distinct amplitude, shape and timing of pressure pulses. This paper investigates dynamic behaviour of a single trapped air pocket. The air pocket is incorporated as a boundary condition into the discrete gas cavity model (DGCM). DGCM allows small gas cavities to form at computational sections in the method of characteristics (MOC). The growth of the pocket and gas cavities is described by the water hammer compatibility equation(s), the continuity equation for the cavity volume, and the equation of state of an ideal gas. Isentropic behaviour is assumed for the trapped gas pocket and an isothermal bath for small gas cavities. Experimental investigations have been performed in a laboratory pipeline apparatus. The apparatus consists of an upstream end high-pressure tank, a horizontal steel pipeline (total length 55.37 m, inner diameter 18 mm), four valve units positioned along the pipeline including the end points, and a downstream end tank. A trapped air pocket is captured between two ball valves at the downstream end of the pipeline. The transient event is initiated by rapid opening of the upstream end valve; the downstream end valve stays closed during the event. Predicted and measured results for a few typical cases are compared and discussed.
Fluid mechanics of heart valves.
Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S
2004-01-01
Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil... oil shutoff means must not prevent feathering the propeller, unless equivalent safety provisions are...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil... oil shutoff means must not prevent feathering the propeller, unless equivalent safety provisions are...
Code of Federal Regulations, 2011 CFR
2011-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2010 CFR
2010-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2013 CFR
2013-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2014 CFR
2014-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2012 CFR
2012-10-01
... remote control valve as follows: (1) Check valve means a valve that permits fluid to flow freely in one direction and contains a mechanism to automatically prevent flow in the other direction. (2) Remote control.... The RCV is usually operated by the supervisory control and data acquisition (SCADA) system. The...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil... oil shutoff means must not prevent feathering the propeller, unless equivalent safety provisions are...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil... oil shutoff means must not prevent feathering the propeller, unless equivalent safety provisions are...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Oil valves. 121.239 Section 121.239..., FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.239 Oil valves. (a) Each oil... oil shutoff means must not prevent feathering the propeller, unless equivalent safety provisions are...
Early and late outcomes of 1000 minimally invasive aortic valve operations.
Tabata, Minoru; Umakanthan, Ramanan; Cohn, Lawrence H; Bolman, Ralph Morton; Shekar, Prem S; Chen, Frederick Y; Couper, Gregory S; Aranki, Sary F
2008-04-01
Minimal access cardiac valve surgery is increasingly utilized. We report our 11-year experience with minimally invasive aortic valve surgery. From 07/96 to 12/06, 1005 patients underwent minimally invasive aortic valve surgery. Early and late outcomes were analyzed. Median patient age was 68 years (range: 24-95), 179 patients (18%) were 80 years or older, 130 patients (13%) had reoperative aortic valve surgery, 86 (8.4%) had aortic root replacement, 62 (6.1%) had concomitant ascending aortic replacement, and 26 (2.6%) had percutaneous coronary intervention on the day of surgery (hybrid procedure). Operative mortality was 1.9% (19/1005). The incidences of deep sternal wound infection, pneumonia and reoperation for bleeding were 0.5% (5/1005), 1.3% (13/1005) and 2.4% (25/1005), respectively. Median length of stay was 6 days and 733 patients (72%) were discharged home. Actuarial survival was 91% at 5 years and 88% at 10 years. In the subgroup of the elderly (> or =80 years), operative mortality was 1.7% (3/179), median length of stay was 8 days and 66 patients (37%) were discharged home. Actuarial survival at 5 years was 84%. There was a significant decreasing trend in cardiopulmonary bypass time, the incidence of bleeding, and operative mortality over time. Minimal access approaches in aortic valve surgery are safe and feasible with excellent outcomes. Aortic root replacement, ascending aortic replacement, and reoperative surgery can be performed with these approaches. These procedures are particularly well-tolerated in the elderly.
Surgical treatment of Behçet's disease involving aortic regurgitation.
Ando, M; Kosakai, Y; Okita, Y; Nakano, K; Kitamura, S
1999-12-01
Behçet's disease involving aortic regurgitation is rare, and prosthetic valve detachment after aortic valve replacement is one of the most serious complications reported. We investigated the surgical results in 10 patients with aortic regurgitation caused by Behçet's disease. Between 1981 and 1997, 10 patients with aortic regurgitation secondary to Behçet's disease had surgery. There were 8 men and 2 women, and their ages ranged from 33 to 60 years (mean, 46+/-8 years). The surgical procedures for aortic regurgitation were aortic valve replacement in 6 patients and Bentall type operation in 4. No patient died during the hospital stay. The follow-up periods ranged from 11 to 185 months (mean, 87 months). Two patients died during the follow-up period. The acturial survival rate was 89% at 5 years and 67% at 10 years. Prosthetic valve detachment or suture detachment requiring redo operation occurred in 4 patients, 3 of whom had redo operations twice. Four patients had a composite graft replacement, and 1 patient died after the operation. No prosthetic valve detachment was noted in 64% of the patients at 5 years and in 43% at 10 years. The rate of prosthetic valve detachment was 40% (4 of 10 patients), with a higher incidence in patients with Behçet's disease than in those treated during the same period at the same hospital for aortitis caused by other diseases. Surgical techniques for treatment of this condition should be modified to improve the surgical outcome in these patients.
Extended range heat pump system and centrifugal compressor for use therewith
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shoemaker, J.F.
1988-04-26
Improvements in heat pump systems having indoor and outdoor heat exchangers and at least two compressors for supplying a refrigerant medium under pressure thereto, and means for circulating the medium through the heat exchangers, the improvement is described comprising a selector valve associated with each of the compressors. The selector valves provide that any combination and any one or more of the compressors can be selected for operation, each of the selector valves having a first operating condition placing the associated compressor in series with the heat exchangers and a second operating condition whereby the associated compressor is bypassed, whenmore » the selector valves for at least two of the compressors are simultaneously in their first positions a flow path is established through the associated compressors and through the heat exchangers all in series, a two position changeover valve and associated conduit means. The changeover valve has a first position wherein at least one of the compressors is connected in series with the first and second heat exchangers to produce flow of the medium in one direction therethrough and a second position whereby at least one compressor is connected to produce flow of the medium in the opposite direction through the heat exchangers.« less
System and method for damping vibration in a drill string using a magnetorheological damper
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wassell, Mark Ellsworth; Burgess, Daniel E; Barbely, Jason R
2012-01-03
A system for damping vibration in a drill string can include a magnetorheological fluid valve assembly having a supply of a magnetorheological fluid, a first member, and a second member capable of moving in relation to first member in response to vibration of the drill bit. The first and second members define a first and a second chamber for holding the fluid. Fluid can flow between the first and second chambers in response to the movement of the second member in relation to the first member. The valve assembly can also include a coil for inducing a magnetic field thatmore » alters the resistance of the magnetorheological fluid to flow between the first and second chambers, thereby increasing the damping provided by the valve. A remnant magnetic field is induced in one or more components of the magnetorheological fluid valve during operation that can be used to provide the magnetic field for operating the valve so as to eliminate the need to energize the coils during operation except temporarily when changing the amount of damping required, thereby eliminating the need for a turbine alternator power the magnetorheological fluid valve. A demagnetization cycle can be used to reduce the remnant magnetic field when necessary.« less
Non-cardiac surgery in patients with prosthetic heart valves: a 12 years experience.
Akhtar, Raja Parvez; Abid, Abdul Rehman; Zafar, Hasnain; Gardezi, Syed Javed Raza; Waheed, Abdul; Khan, Jawad Sajid
2007-10-01
To study patients with mechanical heart valves undergoing non-cardiac surgery and their anticoagulation management during these procedures. It was a cohort study. The study was conducted at the Department of Cardiac Surgery, Punjab Institute of Cardiology, Lahore and Department of Surgery, Services Institute of Medical Sciences, Lahore, from September 1994 to June 2006. Patients with mechanical heart valves undergoing non-cardiac surgical operation during this period, were included. Their anticoagulation was monitored and anticoagulation related complications were recorded. In this study, 507 consecutive patients with a mechanical heart valve replacement were followed-up. Forty two (8.28%) patients underwent non-cardiac surgical operations of which 24 (57.1%) were for abdominal and non-abdominal surgeries, 5 (20.8%) were emergency and 19 (79.2%) were planned. There were 18 (42.9%) caesarean sections for pregnancies. Among the 24 procedures, there were 7(29.1%) laparotomies, 7(29.1%) hernia repairs, 2 (8.3%) cholecystectomies, 2 (8.3%) hysterectomies, 1(4.1%) craniotomy, 1(4.1%) spinal surgery for neuroblastoma, 1(4.1%) ankle fracture and 1(4.1%) carbuncle. No untoward valve or anticoagulation related complication was seen during this period. Patients with mechanical valve prosthesis on life-long anticoagulation, if managed properly, can undergo any type of non-cardiac surgical operation with minimal risk.
Long-term performance of the Hancock bioprosthetic valved conduit in the aortic root position.
Badiu, Catalin C; Bleiziffer, Sabine; Eichinger, Walter B; Hettich, Ina; Krane, Markus; Bauernschmitt, Robert; Lange, Rüdiger
2011-03-01
The study aim was to assess long-term morbidity and mortality with special regard to prosthesis durability after aortic root replacement with the Hancock bioprosthetic porcine conduit. Between 1975 and 2004, a total of 81 patients (55 males, 26 females; mean age 58 +/- 18 years) underwent aortic root replacement with the Hancock conduit for aortic dissection (n = 22; 27%), ascending aortic aneurysm (n = 57; 70%), or porcelain aorta (n = 2; 3%). Twenty-five patients (31%) underwent an emergency operation, 12 (15%) presented with Marfan syndrome, and eight (10%) had undergone previous cardiac surgery. Concomitant procedures were performed in 26 cases (32%). The follow up was 98% complete; the mean follow up was 4.8 +/- 4.0 years (range: 1 day to 16.7 years), and the cumulative follow up was 403 patient-years. Actuarial event-free rates were calculated, and valve-related complications classified according to guidelines for reporting morbidity and mortality after cardiac valvular operations. There were seven (9%) operative deaths and four (5%) in-hospital deaths. Actuarial survival rates at five and 10 years (excluding operative deaths) were 77.0 +/- 5.3% and 54.0 +/- 7.5%, respectively. Actuarial freedom from aortic valve reoperation at five and 10 years was 98 +/- 1.6% and 64 +/- 10.2%, from structural valve deterioration 88.1 +/- 4.7% and 49.9 +/- 9.6%, from thromboembolic events 87.4 +/- 4.6% and 75.1 +/- 9.5%, and from major bleeding events 90.2 +/- 3.9% and 75.4 +/- 8.1%, respectively. Among redo procedures, the stentless Hancock valve could be excised without separating the synthetic graft from the left ventricular outflow tract, and a stented valve prosthesis thus implanted. Hence, it was possible to avoid a second Bentall operation. The long-term survival rates after aortic root replacement with the bioprosthetic Hancock conduit were reasonable for this demanding patient cohort. However, the durability of the prosthesis was inferior to that reported for the stented Hancock valve substitute. The key benefit of this bioprosthetic valved conduit was the simplified redo procedure.
78 FR 56182 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-12
... if certain motor-operated shutoff valve actuators for the fuel tanks are installed, and related...-operated shutoff valve actuators for the fuel tanks are installed, and related investigative and corrective... the different unsafe condition is applicable to all actuator locations required by AD 2008-06-03. We...
76 FR 15814 - Airworthiness Directives; The Boeing Company Model 747 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-22
... listed above. This AD requires measuring the electrical bond resistance between the motor operated valve... SNPRM proposed to require measuring the electrical bond resistance between the motor operated valve (MOV... the relevant data, considered the comment received, and determined that air safety and the public...
Miniature piezo electric vacuum inlet valve
Keville, Robert F.; Dietrich, Daniel D.
1998-03-24
A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (<1.6 watts), high pulse rate (<2 milliseconds), variable flow inlet valve is utilized for mass spectroscopic applications or other applications where pulsed or continuous flow conditions are needed. The inlet valve also has a very minimal dead volume of less than 0.01 std/cc. The valve can utilize, for example, a 12 Vdc input/750 Vdc, 3 mA output power supply compared to conventional piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.
Noise generated by flow through large butterfly valves
NASA Technical Reports Server (NTRS)
Huff, Ronald G.
1987-01-01
A large butterfly valve (1.37 m diam) was acoustically tested to measure the noise generated and propagating in both the upstream and downstream directions. The experimental investigation used wall mounted pressure transducers to measure the fluctuating component of the pipe static pressure upstream and downstream of the valve. Microphones upstream of the pipe inlet and located in a plenum were used to measure the noise radiated from the valve in the upstream direction. Comparison of the wall pressure downstream of the valve to a prediction were made. Reasonable agreement was obtained with the valve operating at a choked condition. The noise upstream of the valve is 30 dB less than that measured downstream.
Lin, Yanjuan; Xu, Le; Huang, Xizhen; Jiang, Fei; Lin, Fen; Ye, Qingyang; Lin, Jianling
2016-01-01
To investigate the effects of non-drug interventions on the sleep quality of patients after mechanical cardiac valve implantation. In this prospective, randomized, controlled trial, 64 patients scheduled for mechanical mitral valve replacement were recruited. Patients underwent cognitive behavioral therapy and wore noise cancelling earplugs and eye mask. Sleep quality was evaluated on the 4th after admission and the 5th days after operation. The primary outcome was the total sleep quality score differences between the 4th day after admission and the 5th day after operation. All patients had been suffering from poor sleep quality for a month before admission. There was no difference between both groups on the 4th day after admission. Overall sleep quality in the intervention group was better than in the control group on the 5th day after operation. The subjective sleep quality of the patients in each group was significantly lower on the 5th day after the operation than on the 4th day after admission (P <0.05). Non-drug intervention could improve the sleep quality of patients after mechanical cardiac valve implantation and help the postoperative recovery of the patients. ( ChiCTR-TRC-14004405, 21 March 2014.).
Aorta-atria-septum combined incision for aortic valve re-replacement
Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong
2018-01-01
This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170
Fluid valve with wide temperature range
NASA Technical Reports Server (NTRS)
Kast, Howard Berdolt (Inventor)
1976-01-01
A fluid valve suitable for either metering or pressure regulating fluids at various temperatures is provided for a fuel system as may be utilized in an aircraft gas turbine engine. The valve includes a ceramic or carbon pad which cooperates with a window in a valve plate to provide a variable area orifice which remains operational during large and sometimes rapid variations in temperature incurred from the use of different fuels.
Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper; Jensen, Maiken Brit; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann
2017-08-01
Aortic valve stenosis alters blood flow in the ascending aorta. Using intra-operative vector flow imaging on the ascending aorta, secondary helical flow during peak systole and diastole, as well as flow complexity of primary flow during systole, were investigated in patients with normal, stenotic and replaced aortic valves. Peak systolic helical flow, diastolic helical flow and flow complexity during systole differed between the groups (p < 0.0001), and correlated to peak systolic velocity (R = 0.94, 0.87 and 0.88, respectively). The study indicates that aortic valve stenosis increases helical flow and flow complexity, which are measurable with vector flow imaging. For assessment of aortic stenosis and optimization of valve surgery, vector flow imaging may be useful. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
A Preliminary Study on Rock Bed Heat Storage from Biomass Combustion for Rice Drying
NASA Astrophysics Data System (ADS)
Nelwan, L. O.; Wulandani, D.; Subrata, I. D. M.
2018-05-01
One of the main constraints of biomass fuel utilization in a small scale rice drying system is the operating difficulties related to the adjustment of combustion/feeding rate. Use of thermal storage may reduce the problem since combustion operation can be accomplished in a much shorter time and then the use of heat can be regulated by simply adjusting the air flow. An integrated biomass furnace-rock bed thermal storage with a storage volume of 540 L was designed and tested. There were four experiments conducted in this study. Charging was performed within 1-2 hours with a combustion rate of 11.5-15.5 kg/h. In discharging process, the mixing of air passing through the rock bed and ambient air were regulated by valves. Without adjusting the valve during the discharging process, air temperature increased up to 80°C, which is not suitable for rice batch drying process. Charging with sufficiently high combustion rate (14 kg/h) within 1 hour continued by adjusting the valve during discharging process below 60°C increased the discharge-charge time ratio (DCTR) up to 5.33 at average air temperature of 49°C and ambient temperature of 33°C.The efficiency of heat discharging was ranged from 34.5 to 45.8%. From the simulation, as much as 156.8-268.8 kg of rice was able to be dried by the discharging conditions.
NASA Technical Reports Server (NTRS)
Neiner, G. H.; Dustin, M. O.; Cole, G. L.
1979-01-01
A stability-bleed system was installed in a YF-12 flight inlet that was subjected to internal and external airflow disturbances in the NASA Lewis 10 by 10 foot supersonic wind tunnel. The purpose of the system is to allow higher inlet performance while maintaining a substantial tolerance (without unstart) to internal and external disturbances. At Mach numbers of 2.47 and 2.76, the inlet tolerance to decreases in diffuser-exit corrected airflow was increased by approximately 10 percent of the operating-point airflow. The stability-bleed system complemented the terminal-shock-control system of the inlet and did not show interaction problems. For disturbances which caused a combined decrease in Mach number and increase in angle of attack, the system with valves operative kept the inlet started 4 to 28 times longer than with the valves inoperative. Hence, the stability system provides additional time for the inlet control system to react and prevent unstart. This was observed for initial Mach numbers of 2.55 and 2.68. For slow increase in angle of attack at Mach 2.47 and 2.76, the system kept the inlet started beyond the steady-state unstart angle. However, the maximum transient angles of attack without unstart could not be determined because wind-tunnel mechanical-stop limits for angle of attack were reached.
40 CFR 1054.230 - How do I select emission families?
Code of Federal Regulations, 2010 CFR
2010-07-01
...). (3) Valve configuration (for example, side-valve vs. overhead valve). (4) Method of air aspiration... configuration) and approximate total displacement. (7) Engine class, as defined in § 1054.801. (8) Method of control for engine operation, other than governing (mechanical or electronic). (9) The numerical level of...
2017-11-28
Patients Waiting for Elective Isolated Coronary Artery Bypass Grafting (CABG); Patients Waiting for Aortic Valve Repair/Replacement for Moderate Aortic Stenosis or Severe Regurgitation; Patients Waiting for Mitral Valve Repair/Replacement for Moderate Stenosis or Severe Regurgitation; Patients Waiting for Combined Procedures. (CAGB and Valve)
Single module pressurized fuel cell turbine generator system
George, Raymond A.; Veyo, Stephen E.; Dederer, Jeffrey T.
2001-01-01
A pressurized fuel cell system (10), operates within a common pressure vessel (12) where the system contains fuel cells (22), a turbine (26) and a generator (98) where preferably, associated oxidant inlet valve (52), fuel inlet valve (56) and fuel cell exhaust valve (42) are outside the pressure vessel.
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2013 CFR
2013-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2012 CFR
2012-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2011 CFR
2011-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
46 CFR 98.25-40 - Valves, fittings, and accessories.
Code of Federal Regulations, 2014 CFR
2014-10-01
... located at the highest practical point. The thermometer well shall terminate in the liquid space and be... and discharge liquid and vapor shut-off valves, safety relief valves, liquid level gaging devices... to the tanks, except safety devices and liquid level gaging devices, shall have manually operated...
46 CFR 185.608 - Fuel shutoff valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Fuel shutoff valves. 185.608 Section 185.608 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Markings Required § 185.608 Fuel shutoff valves. Remote fuel shutoff stations must be marked in...
46 CFR 185.608 - Fuel shutoff valves.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fuel shutoff valves. 185.608 Section 185.608 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Markings Required § 185.608 Fuel shutoff valves. Remote fuel shutoff stations must be marked in...
46 CFR 185.608 - Fuel shutoff valves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Fuel shutoff valves. 185.608 Section 185.608 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SMALL PASSENGER VESSELS (UNDER 100 GROSS TONS) OPERATIONS Markings Required § 185.608 Fuel shutoff valves. Remote fuel shutoff stations must be marked in...
Severe Tricuspid Regurgitation Diagnosed 13 Years after a Car Accident: A Case Report
Acar, Burak; Suleymanoglu, Muhammed; Burak, Cengiz; Demirkan, Burcu Mecit; Guray, Yesim; Tufekcioglu, Omac; Aydogdu, Sinan
2015-01-01
Abstract Blunt chest traumas mostly occur due to car accidents and can cause many cardiac complications such as septal rupture, free-wall rupture, coronary artery dissection or thrombosis, heart failure, arrhythmias, and chordae and papillary muscle rupture. One of the most serious complication is tricuspid regurgitation (TR), which can be simply diagnosed by physical examination and confirmed by echocardiography. We describe a 48-year-old female patient, diagnosed with severe TR 13 years after a blunt chest trauma due to a car accident. TR was diagnosed with transthoracic echocardiography and three dimensional transthoracic echocardiography had defined the exact pathology of the tricuspid valve. The patient underwent successful surgery with bioprosthetic valve implantation and was discharged at 6th postoperative day without any complication. The patient had no problem according to the follow-up one month and six months after operation. PMID:26157464
Application of Model-based Prognostics to a Pneumatic Valves Testbed
NASA Technical Reports Server (NTRS)
Daigle, Matthew; Kulkarni, Chetan S.; Gorospe, George
2014-01-01
Pneumatic-actuated valves play an important role in many applications, including cryogenic propellant loading for space operations. Model-based prognostics emphasizes the importance of a model that describes the nominal and faulty behavior of a system, and how faulty behavior progresses in time, causing the end of useful life of the system. We describe the construction of a testbed consisting of a pneumatic valve that allows the injection of faulty behavior and controllable fault progression. The valve opens discretely, and is controlled through a solenoid valve. Controllable leaks of pneumatic gas in the testbed are introduced through proportional valves, allowing the testing and validation of prognostics algorithms for pneumatic valves. A new valve prognostics approach is developed that estimates fault progression and predicts remaining life based only on valve timing measurements. Simulation experiments demonstrate and validate the approach.
Altitude valve for railway suspension control system
NASA Astrophysics Data System (ADS)
Zhang, Xuan; Zhang, Lihao; Li, Qingxuan; Chen, WanSong
2017-09-01
With the variation of people and material during vehicle service, the gravity of vehicle could be unbalanced. As a result it might cause accident. In order to solve this problem, altitude valve is assembled on board. It can adjust the gravity of vehicle by the intake and outlet progress of the spring in the altitude valve to prevent the tilt of vehicles.
Relation of Mitral Valve Surgery Volume to Repair Rate, Durability, and Survival.
Chikwe, Joanna; Toyoda, Nana; Anyanwu, Anelechi C; Itagaki, Shinobu; Egorova, Natalia N; Boateng, Percy; El-Eshmawi, Ahmed; Adams, David H
2017-04-24
Degenerative mitral valve repair rates remain highly variable, despite established benefits of repair over replacement. The contribution of surgeon-specific factors is poorly defined. This study evaluated the influence of surgeon case volume on degenerative mitral valve repair rates and outcomes. A mandatory New York State database was queried and 5,475 patients were identified with degenerative mitral disease who underwent mitral valve operations between 2002 and 2013. Mitral repair rates, mitral reoperations within 12 months of repair, and survival were analyzed using multivariable Cox modeling and restricted cubic spline function. Median annual surgeon volume of any mitral operations was 10 (range 1 to 230), with a mean repair rate of 55% (n = 20,797 of 38,128). In the subgroup of patients with degenerative disease, the mean repair rate was 67% (n = 3,660 of 5,475), with a range of 0% to 100%. Mean repair rates ranged from 48% (n = 179 of 370) for surgeons with total annual volumes of ≤10 mitral operations to 77% (n = 1,710 of 2,216) for surgeons with total annual volumes of >50 mitral operations (p < 0.001). Higher total annual surgeon volume was associated with increased repair rates of degenerative mitral valve disease (adjusted odds ratio [OR]: 1.13 for every additional 10 mitral operations; 95% confidence interval [CI]: 1.10 to 1.17; p < 0.001); a steady decrease in reoperation risk until 25 total mitral operations annually; and improved 1-year survival (adjusted hazard ratio: 0.95 for every additional 10 operations; 95% CI: 0.92 to 0.98; p = 0.001). For surgeons with a total annual volume of ≤25 mitral operations, repair rates were higher (63.8%; n = 180 of 282) if they operated in the same institution as a surgeon with total annual mitral volumes of >50 and degenerative mitral valve repair rates of >70%, compared with surgeons operating in the other institutions (51.3%; n = 580 of 1,130) (adjusted OR: 1.79; 95% CI: 1.24 to 2.60; p < 0.001). This study suggests that individual surgeon volume is a determinant of not only mitral repair rates, but also freedom from reoperation, and survival. The data from this study support the guideline's concept of reference referral to experienced mitral surgeons to improve outcomes in patients with degenerative mitral valve disease. Copyright © 2017. Published by Elsevier Inc.
[Long-term outcomes of Ahmed glaucoma valve implantation for treating refractory glaucoma].
Xu, Yumei; Hong, Tao; Li, Wanming
2015-02-10
To explore the efficacies and complications of Ahmed glaucoma valve implantation for treating refractory glaucoma. A retrospective study of case series was conducted for 24 patients (26 eyes) with refractory glaucoma from February 2001 to July 2008 at our hospital. Ahmed glaucoma valve implantation was performed. Pre- and post-operative best spectacle-corrected visual acuity (BSCVA), intraocular pressure (IOP), number of medications and complications were recorded and analyzed. The follow-up period was 58-159 months. The post-operative values of IOP were 13.02+/-6.79, 11.43+/-5.24 and 18.56+/-6.43 mmHg at 1 day, 1 month and the last follow-up respectively. There were significant difference when compared with pre-operative IOP (37.59+/-10.76 mmHg, P < 0.01). And 65.38% of eyes maintained or gained ≥ 1 line of BSCVA. But there was no significant difference with pre-operative BSCVA (P = 0.110). Twenty eyes required anti-glaucoma drugs after glaucoma valve implantation and the average number of medication was 1.72+/-0.98. There was significant difference with the pre-operative medication number 2.7 ± 0.7 (P = 0.001). The surgical success rate was 73.1%. And the causes of failure were endophthalmitis, corneal endothelial decompensation, persistent conjunctival wound non-healing, glaucoma valve exposure and loss of light perception.Early postoperative complications were ocular hypotony, shallow anterior chamber, hyphema, transient high IOP and tube occlusion. And long-term complications included encapsulated cyst formation, tube exposure, corneal endothelial decompensation and endophthalmitis. Ahmed glaucoma valve implantation is efficacious for refractory glaucoma.However, clinicians should pay attention to the prevention and treatment of complications.
Yue, Yinling; Zhang, Lan; Ling, Bo
2011-11-01
To investigate the phenomenon of bacteria exceeding standards in rural pit water, which was intermittently operated by water pump equipped with ultrafiltration membrane, and to explore the solutions. Polyvinyl chloride (PVC) alloy capillary membranes combined with UV, disinfectant, one-way valve, water-seal, high water level-water tank and direct outlet were tested. The operation on water treatment was intermittent, simulating the ways of treating pit water in the rural. The combination modes of ultrafiltration membrane with UV, disinfectant and high water level-water tank are valid in solving the problem of high turbidity and microorganism of pit water stored in cellars, the quality of effluents was consistent with the requirements of the national standards. While the combination modes of ultrafiltration membrane with one-way valve or water-seal were less desirable, more bacteria in treated water than raw water were observed because of bacteria breeding on the membrane component. In order to avoid excessive bacteria in filtered pit water caused by intermittent operation, it is recommended that for the pit water in high water level water tanks, the ultrafiltration membranes should be cleaned with disinfectants on a regular basis. The effluent pit water from underground cellars should be disinfected with UV after ultrafiltration.
Living nano-micro fibrous woven fabric/hydrogel composite scaffolds for heart valve engineering.
Wu, Shaohua; Duan, Bin; Qin, Xiaohong; Butcher, Jonathan T
2017-03-15
Regeneration and repair of injured or diseased heart valves remains a clinical challenge. Tissue engineering provides a promising treatment approach to facilitate living heart valve repair and regeneration. Three-dimensional (3D) biomimetic scaffolds that possess heterogeneous and anisotropic features that approximate those of native heart valve tissue are beneficial to the successful in vitro development of tissue engineered heart valves (TEHV). Here we report the development and characterization of a novel composite scaffold consisting of nano- and micro-scale fibrous woven fabrics and 3D hydrogels by using textile techniques combined with bioactive hydrogel formation. Embedded nano-micro fibrous scaffolds within hydrogel enhanced mechanical strength and physical structural anisotropy of the composite scaffold (similar to native aortic valve leaflets) and also reduced its compaction. We determined that the composite scaffolds supported the growth of human aortic valve interstitial cells (HAVIC), balanced the remodeling of heart valve ECM against shrinkage, and maintained better physiological fibroblastic phenotype in both normal and diseased HAVIC over single materials. These fabricated composite scaffolds enable the engineering of a living heart valve graft with improved anisotropic structure and tissue biomechanics important for maintaining valve cell phenotypes. Heart valve-related disease is an important clinical problem, with over 300,000 surgical repairs performed annually. Tissue engineering offers a promising strategy for heart valve repair and regeneration. In this study, we developed and tissue engineered living nano-micro fibrous woven fabric/hydrogel composite scaffolds by using textile technique combined with bioactive hydrogel formation. The novelty of our technique is that the composite scaffolds can mimic physical structure anisotropy and the mechanical strength of natural aortic valve leaflet. Moreover, the composite scaffolds prevented the matrix shrinkage, which is major problem that causes the failure of TEHV, and better maintained physiological fibroblastic phenotype in both normal and diseased HAVIC. This work marks the first report of a combination composite scaffold using 3D hydrogel enhanced by nano-micro fibrous woven fabric, and represents a promising tissue engineering strategy to treat heart valve injury. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Jung, Joonho; Lee, Cheol Joo; Lim, Sang-Hyun; Choi, Ho; Park, Soo-Jin
2013-01-01
A 51-year-old male was admitted to the hospital with complaints of fever and hemoptysis. After evaluation of the fever focus, he was diagnosed with pulmonary valve infective endocarditis. Thus pulmonary valve replacement and antibiotics therapy were performed and discharged. He was brought to the emergency unit presenting with a high fever (>39℃) and general weakness 6 months after the initial operation. The echocardiography revealed prosthetic pulmonary valve endocarditis. Therefore, redo-pulmonary valve replacement using valved conduit was performed in the Rastelli fashion because of the risk of pulmonary arterial wall injury and recurrent endocarditis from the remnant inflammatory tissue. We report here on the successful surgical treatment of prosthetic pulmonary valve endocarditis with an alternative surgical method. PMID:23772409
Spin filter and spin valve in ferromagnetic graphene
DOE Office of Scientific and Technical Information (OSTI.GOV)
Song, Yu, E-mail: kwungyusung@gmail.com; Dai, Gang; Research Center for Microsystems and Terahertz, China Academy of Engineering Physics, Mianyang 621999
2015-06-01
We propose and demonstrate that a EuO-induced and top-gated graphene ferromagnetic junction can be simultaneously operated as a spin filter and a spin valve. We attribute such a remarkable result to a coexistence of a half-metal band and a common energy gap for opposite spins in ferromagnetic graphene. We show that both the spin filter and the spin valve can be effectively controlled by a back gate voltage, and they survive for practical metal contacts and finite temperature. Specifically, larger single spin currents and on-state currents can be reached with contacts with work functions similar to graphene, and the spinmore » filter can operate at higher temperature than the spin valve.« less
Reduced-order modellin for high-pressure transient flow of hydrogen-natural gas mixture
NASA Astrophysics Data System (ADS)
Agaie, Baba G.; Khan, Ilyas; Alshomrani, Ali Saleh; Alqahtani, Aisha M.
2017-05-01
In this paper the transient flow of hydrogen compressed-natural gas (HCNG) mixture which is also referred to as hydrogen-natural gas mixture in a pipeline is numerically computed using the reduced-order modelling technique. The study on transient conditions is important because the pipeline flows are normally in the unsteady state due to the sudden opening and closure of control valves, but most of the existing studies only analyse the flow in the steady-state conditions. The mathematical model consists in a set of non-linear conservation forms of partial differential equations. The objective of this paper is to improve the accuracy in the prediction of the HCNG transient flow parameters using the Reduced-Order Modelling (ROM). The ROM technique has been successfully used in single-gas and aerodynamic flow problems, the gas mixture has not been done using the ROM. The study is based on the velocity change created by the operation of the valves upstream and downstream the pipeline. Results on the flow characteristics, namely the pressure, density, celerity and mass flux are based on variations of the mixing ratio and valve reaction and actuation time; the ROM computational time cost advantage are also presented.
NASA Astrophysics Data System (ADS)
Simola, Kaisa; Laakso, Kari
1992-01-01
Eight years of operating experiences of 104 motor operated closing valves in different safety systems in nuclear power units were analyzed in a systematic way. The qualitative methods used were Failure Mode and Effect Analysis (FMEA) and Maintenance Effects and Criticality Analysis (MECA). These reliability engineering methods are commonly used in the design stage of equipment. The successful application of these methods for analysis and utilization of operating experiences was demonstrated.
Additively Manufactured Main Fuel Valve Housing
NASA Technical Reports Server (NTRS)
Eddleman, David; Richard, Jim
2015-01-01
Selective Laser Melting (SLM) was utilized to fabricate a liquid hydrogen valve housing typical of those found in rocket engines and main propulsion systems. The SLM process allowed for a valve geometry that would be difficult, if not impossible to fabricate by traditional means. Several valve bodies were built by different SLM suppliers and assembled with valve internals. The assemblies were then tested with liquid nitrogen and operated as desired. One unit was also burst tested and sectioned for materials analysis. The design, test results, and planned testing are presented herein.
A Simple Device for Morphofunctional Evaluation During Aortic Valve-Sparing Surgery.
Leone, Alessandro; Bruno, Piergiorgio; Cammertoni, Federico; Massetti, Massimo
2015-07-01
Valve-sparing operations for the treatment of aortic root disease with a structurally normal aortic valve are increasingly performed as they avoid prosthesis-related complications. Short- and long-term results are critically dependent on perfect intraoperative restoration of valve anatomy and function. Residual aortic regurgitation is the main cause of early failure, and it is the most common motive for reoperation. However, intraoperative morphofunctional valve assessment requires expertise, and only transesophageal echocardiography can provide reliable information. We describe a simple, economic, reproducible hydrostatic test to intraoperatively evaluate valve competency under direct visualization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Myectomy and LA-to-LV Conduit for Severe Calcific Mitral Stenosis and Hypertrophic Cardiomyopathy.
Meghji, Zahara; Nguyen, Anita; Geske, Jeffrey B; Schaff, Hartzell V
2018-02-26
Severe calcific mitral valve stenosis can rarely occur concomitantly with obstructive hypertrophic cardiomyopathy. In these patients, surgical decalcification of the stenotic mitral valve followed by mitral valve replacement carries significant operative risk and may result in paravalvular leakage, atrioventricular groove disruption, and excessive bleeding. We report the first 2 cases of obstructive hypertrophic cardiomyopathy with severe calcific mitral valve stenosis successfully treated with concomitant transaortic septal myectomy and bypass of the stenotic mitral valve using a valved left atrium to left ventricular conduit. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Concomitant transcatheter aortic valve and left ventricular assist device implantation.
Baum, Christina; Seiffert, Moritz; Treede, Hendrik; Reichenspurner, Hermann; Deuse, Tobias
2013-01-01
Relevant aortic regurgitation (AR) requires surgical repair at the time of left ventricular assist device (LVAD) implantation to reduce recirculation and ensure adequate forward flow. We report here on a patient with moderate AR in a noncalcified aortic valve and extensive calcification of the ascending aorta. The latter precluded aortic-crossclamping and, thus, surgical intervention on the aortic valve. Although there were no valvular or annular calcifications, a JenaValve transcatheter heart valve was successfully placed transapically with subsequent LVAD implantation in one operation. We believe concomitant transcatheter aortic valve implantation (TAVI) and LVAD implantation is a promising hybrid procedure, even in patients with pure AR.
Fast acting multiple element valve
Yang, Jefferson Y. S.; Wada, James M.
1991-01-01
A plurality of slide valve elements having plural axial-spaced annular parts and an internal slide are inserted into a bulkhead in a fluid conduit from a downstream side of the bulkhead, locked in place by a bayonet coupling and set screw, and project through the bulkhead into the upstream conduit. Pneumatic lines connecting the slide valve element actuator to pilot valves are brought out the throat of the valve element to the downstream side. Pilot valves are radially spaced around the exterior of the valve to permit the pneumatic lines to be made identical, thereby to minimize adverse timing tolerances in operation due to pressure variations. Ring manifolds surround the valve adjacent respective pilot valve arrangements to further reduce adverse timing tolerances due to pressure variations, the manifolds being directly connected to the respective pilot valves. Position sensors are provided the valve element slides to signal the precise time at which a slide reaches or passes through a particular point in its stroke to initiate a calibrated timing function.
40 CFR 63.1019 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... leaks are placed here for administrative convenience and only apply to those owners and operators of... relief devices, sampling connection systems, open-ended valves or lines, valves, connectors...
49 CFR 195.428 - Overpressure safety devices and overfill protection systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... months, but at least twice each calendar year, inspect and test each pressure limiting device, relief... reliability of operation for the service in which it is used. (b) In the case of relief valves on pressure breakout tanks containing highly volatile liquids, each operator shall test each valve at intervals not...
Valve sparing aortic replacement - root remodeling.
Lausberg, Henning F; Schäfers, Hans-Joachim
2006-01-01
Aortic root remodeling restores aortic root geometry and improves valve competence. We have used this technique whenever aorto-ventricular diameter is preserved. The operative technique is detained in this presentation. As a result of our 10-year experience with root remodeling we propose this operation as a reproducible option for patients with dilatation of the aortic root.
30 CFR 250.447 - When must I pressure test the BOP system?
Code of Federal Regulations, 2011 CFR
2011-07-01
..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Oil and Gas Drilling Operations Blowout Preventer (bop) System Requirements § 250.447 When must I pressure... valves, inside BOP, and drill-string safety valve): (a) When installed; (b) Before 14 days have elapsed...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-23
... controverted. In addition, the requestor/petitioner shall provide a brief explanation of the bases for the... New analysis limit 10 CFR 50.67 limit EAB 4.56 rem TEDE Main steam line isolation. Closing the pressurizer power-operated relief valves block valves. Securing all reactor coolant pumps. Feedwater isolation...
Miniature piezo electric vacuum inlet valve
Keville, R.F.; Dietrich, D.D.
1998-03-24
A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability is disclosed. The low power (<1.6 watts), high pulse rate (<2 milliseconds), variable flow inlet valve is utilized for mass spectroscopic applications or other applications where pulsed or continuous flow conditions are needed. The inlet valve also has a very minimal dead volume of less than 0.01 std/cc. The valve can utilize, for example, a 12 Vdc input/750 Vdc, 3 mA output power supply compared to conventional piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three. 6 figs.
49 CFR 393.49 - Control valves for brakes.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., which is equipped with power brakes, must have the braking system so arranged that one application valve must when activated cause all of the service brakes on the motor vehicle or combination motor vehicle... with an additional valve to be used to operate the brakes on a trailer or trailers or as required for...
46 CFR 58.16-15 - Valves and safety relief devices.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 2 2013-10-01 2013-10-01 false Valves and safety relief devices. 58.16-15 Section 58.16-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND... and safety relief devices. (a) Each cylinder shall have a manually operated screw-down shutoff valve...
46 CFR 58.16-15 - Valves and safety relief devices.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 2 2011-10-01 2011-10-01 false Valves and safety relief devices. 58.16-15 Section 58.16-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND... and safety relief devices. (a) Each cylinder shall have a manually operated screw-down shutoff valve...
46 CFR 58.16-15 - Valves and safety relief devices.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 2 2012-10-01 2012-10-01 false Valves and safety relief devices. 58.16-15 Section 58.16-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND... and safety relief devices. (a) Each cylinder shall have a manually operated screw-down shutoff valve...
46 CFR 58.16-15 - Valves and safety relief devices.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 2 2014-10-01 2014-10-01 false Valves and safety relief devices. 58.16-15 Section 58.16-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MAIN AND... and safety relief devices. (a) Each cylinder shall have a manually operated screw-down shutoff valve...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-17
... feedwater valves isolation times to the Licensee Controlled Document that is referenced in the Bases and... Document that is referenced in the Bases. The requirements to perform the testing of these isolation valves... feedwater valve isolation times to the Licensee Controlled Document that is referenced in the Bases. In...
Late complications in patients with Björk-Shiley and St. Jude Medical heart valve replacement.
Horstkotte, D; Körfer, R; Seipel, L; Bircks, W; Loogen, F
1983-09-01
Valve-related complications after Björk-Shiley mitral valve implantation (n = 475), aortic valve implantation (n = 424), or mitral-aortic valve implantation (n = 119) were compared with those after St. Jude Medical mitral valve replacement (n = 173), aortic valve replacement (n = 152), or mitral-aortic valve replacement (n = 69). All patients were placed on anticoagulant therapy with phenprocoumon early after operation. All patients had a comparable follow-up time of approximately 23 months, which showed that cumulative thromboembolic rates were significantly higher after St. Jude valve implantation than after Björk-Shiley valve implantation. Reoperations were necessary because of valve thrombosis (0.46%), perivalvular leakage (2.2%), or prosthetic valve endocarditis with perivalvular regurgitation (0.46%). One Björk-Shiley mitral valve prosthesis had to be replaced because of fracture of the outlet strut. Without significant intergroup differences, hemorrhage due to anticoagulant treatment was the most frequent complication. Thromboembolic complications were significantly more frequent after Björk-Shiley mitral, aortic, and double valve replacements than after St. Jude valve implantation. This may lead to consideration of changes in the prophylaxis of thrombus formations in the St. Jude valve, especially in aortic valve replacements, in patients with sinus rhythm.
NASA Technical Reports Server (NTRS)
Schey, Oscar W; Wilson, Ernest E
1929-01-01
This report presents the results of an analytical investigation on the practicability of using mechanically operated discharge valves in conjunction with a manually operated intake control for improving the performance of N. A. C. A. Roots type superchargers. These valves, which may be either of the oscillating or rotating type, are placed in the discharge opening of the supercharger and are so shaped and synchronized with the supercharger impellers that they do not open until the air has been compressed to the delivery pressure. The intake control limits the quantity of air compressed to engine requirements by permitting the excess air to escape from the compression chamber before compression begins. The percentage power saving and the actual horsepower saved were computed for altitudes from 0 to 20,000 feet. These computations are based on the pressure-volume cards for the conventional and the modified roots type superchargers and on the results of laboratory tests of the conventional type. The use of discharge valves shows a power saving of approximately 26 per cent at a critical altitude of 20,000 feet. In addition, these valves reduce the amplitude of the discharge pulsations and increase the volumetric efficiency. With slow-speed roots blowers operating at high-pressure differences even better results would be expected. For aircraft engine superchargers operating at high speeds these discharge valves increase the performance as above, but have the disadvantages of increasing the weight and of adding a high-speed mechanism to a simple machine. (author)
Xiao, Jian; Yin, Liang; Lin, Yiyun; Zhang, Yufeng; Wu, Lihui; Wang, Zhinong
2016-07-01
Children with infective endocarditis (IE) have to undergo valve replacement instead of valve repair in China due to severe valve damage. The present study is to review our experience on surgical treatment of children with IE in reference to the incidence, pathologic status, diagnosis, surgical strategies and outcomes. We reviewed 35 patients with a mean age of 13.7±2.2 years who were underwent valve replacement surgery for IE during the period from January 1993 to December 2013. Preoperative transthoracic echocardiographic (TTE) evaluation and transesophageal echocardiography during operation were performed in all patients. All the children underwent chart review and retrospective risk-hazard analysis. Among the patients surveyed congenital cardiac lesions were present in 15 (42.8%), rheumatic heart valve disease in 2 (5.7%) and previous heart surgery in 2 (5.7%). The median stay of intensive care unit was 6 days. Intraoperative findings showed that the endocarditis involved mostly the mitral and aortic valves (88.5%). Triple or quadruple valve involvement was found in one patient each. Ten-year freedom from IE-related death and re-intervention was 94.2% and 91.6%, respectively. Children undergoing surgery for IE frequently have advanced disease with embolic complications. Although valve replacement is not the primary option for pediatric IE, the rate of 5-year survival and freedom from re-operation was optimal prognostically. Pediatric physicians should pay attention to the common clinical features of IE so that the native valve is preserved well.
[Femorotomy and cleaning for infected hip prostheses: report of 30 cases].
Lortat-Jacob, A; Nourrissat, G; Cadu, C
2001-10-01
We report infected hip prostheses treated by an original technique: frontal femorotomy after trochanterotomy. This extensive technique enables perfect cleaning of the femur and truly effective freshening of the endomedullar canal. We report 30 cases operated since 1991 use of femorotomy has been systematic from 1995. We were able to reimplant 25 of these 30 hips. Our results after infection were rather good with 4 recurrent infections in difficult cases (multi-operated patients and multiresistant germs in half of the cases). Fusion of femorotomy was obtained in all cases. The mechanical outcome was not improved by femorotomy. The main problem was trochanter nonunion with 5 cases, all of them having had a trochanteromy during the first procedure. We use femorotomy as our routine technique for femoral cleaning in case of hip prosthesis infection. In less complicated cases, we do not remove the trochanter from the femoral valve, limiting trochanteric complications, the main problem with this technique.
NASA Astrophysics Data System (ADS)
Kaiser, Alexander
2016-11-01
The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.
Apparatus and method for non-invasive diagnosis and control of motor operated valve condition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyon, R.H.; Chai, J.; Lang, J.H.
1997-01-14
An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signalmore » and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.« less
Apparatus and method for non-invasive diagnosis and control of motor operated valve condition
Lyon, R.H.; Chai, J.; Lang, J.H.; Hagman, W.H.; Umans, S.D.; Saarela, O.J.
1997-01-14
An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.
Tetralogy of Fallot with absent pulmonary valve syndrome; appropriate surgical strategies.
Shahid, Fatima; Siddiqui, Maria Tariq; Amanullah, Muhammad Muneer
2015-05-01
To evaluate patients presenting with Tetralogy of Fallot with absent pulmonary valve syndrome to a tertiary care hospital and their surgical management. The retrospective study was conducted at Congenital Cardiac Services, Aga Khan University Hospital, Karachi, Pakistan, and comprised data of Tetralogy of Fallot patients between April 2007 and June 2012. Data was analysed together with follow-up echocardiography. Variables assessed included demographics, imaging, operative technique, complications, post-operative recovery and follow-up echocardiography. SPSS 17 was used for statistical analysis. Of the 204 patients, 6 (3%) had undergone surgical correction for Tetralogy of Fallot with absent pulmonary valve syndrome. All 6(100%) patients underwent complete repair. Median age for surgery was 8.5 years (range: 0.5-29 years). Of the different surgical strategies used, Contegra and Bioprosthetic valve placement had satisfactory outcome with minimal gradient at Right Ventricular Outflow Tract, good ventricular function and mild valvular regurgitation. One (16.6%) patient with Trans Annular Patch developed post-operative Right Ventricle Outflow Tract gradient of 80mmHg with moderate pulmonary regurgitation. One (16.6%) patient with monocusp valve developed free pulmonary regurgitation at 6 months. The other 4(66.6%) patients are currently free from any complications or re-intervention. Early surgery is preferred in symptomatic patients. The repair depends upon achieving integrity of pulmonary circulation which is best achieved by using right ventricle to pulmonary artery conduit or inserting a pulmonary valve.
Apparatus and method for non-invasive diagnosis and control of motor operated valve condition
Lyon, Richard H.; Chai, Jangbom; Lang, Jeffrey H.; Hagman, Wayne H.; Umans, Stephen D.; Saarela, Olli J.
1997-01-01
An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit.
Computational Modeling of Liquid and Gaseous Control Valves
NASA Technical Reports Server (NTRS)
Daines, Russell; Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy; Moore, Arden; Sulyma, Peter
2005-01-01
In this paper computational modeling efforts undertaken at NASA Stennis Space Center in support of rocket engine component testing are discussed. Such analyses include structurally complex cryogenic liquid valves and gas valves operating at high pressures and flow rates. Basic modeling and initial successes are documented, and other issues that make valve modeling at SSC somewhat unique are also addressed. These include transient behavior, valve stall, and the determination of flow patterns in LOX valves. Hexahedral structured grids are used for valves that can be simplifies through the use of axisymmetric approximation. Hybrid unstructured methodology is used for structurally complex valves that have disparate length scales and complex flow paths that include strong swirl, local recirculation zones/secondary flow effects. Hexahedral (structured), unstructured, and hybrid meshes are compared for accuracy and computational efficiency. Accuracy is determined using verification and validation techniques.
Bennett, Charles L.
2016-03-22
A reciprocating-piston uniflow engine includes a harmonic oscillator inlet valve capable of oscillating at a resonant frequency for controlling the flow of working fluid into the engine. In particular, the inlet valve includes an inlet valve head and a spring arranged together as a harmonic oscillator so that the inlet valve head is moveable from an unbiased equilibrium position to a biased closed position occluding an inlet. When released, the inlet valve head undergoes a single oscillation past the equilibrium position to a maximum open position and returns to a biased return position close to the closed position to choke the flow and produce a pressure drop across the inlet valve causing the inlet valve to close. In other embodiments, the harmonic oscillator arrangement of the inlet valve enables the uniflow engine to be reversibly operated as a uniflow compressor.
Slide valve apparatus for internal combustion engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor, B.A.; McMahan, T.O.
This patent describes an internal combustion engine including a combustion cylinder having an opening at one end thereof, a piston mounted within the cylinder for coaxial reciprocable movement, a driven crankshaft, and a connecting rod connecting the crankshaft to the cylinder for linear reciprocable movement of the piston in response to the rotary movement of the crankshaft, a valve apparatus comprising: (a) a valve chamber extending longitudinally across and in fluid communication with the opening in the cylinder, (b) an intake valve plate having a longitudinal axis mounted within the valve chamber for slidable, reciprocable, longitudinal movement, (c) an exhaustmore » valve plate having a longitudinal axis mounted within the valve chamber alongside the intake valve plate for slidable, reciprocable, longitudinal movement and parallel to the longitudinal axis of the intake valve plate, (d) each of the valve plates having a plurality of longitudinally spaced valve ports therein, the valve ports comprising movable intake valve ports in the intake valve plate and movable exhaust valve ports in the exhaust valve plate, (e) the valve chamber comprising a planar wall on the opposite side of the valve plates from the cylinder opening and having a plurality of fixed valve ports therethrough. The fixed valve ports being equal in number and substantially equal in size and spacing as the movable intake and exhaust valve ports, whereby the movable intake valve ports are adapted to register with their corresponding fixed valve ports when the intake valve plate is in its intake operative position for opening fluid communication between the cylinder and the corresponding fixed valve ports.« less
Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae; Kim, Chan Yun
2015-04-01
To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9 mmHg in the Ahmed glaucoma valve implantation group (p = 0.73). The 48-month postoperative mean intraocular pressure was 19.6 mmHg in the trabeculectomy group and 20.2 mmHg in the Ahmed glaucoma valve implantation group (p = 0.95). The 12-month trabeculectomy success rate was 69%, compared with 64% for Ahmed glaucoma valve implantation, and the 48-month success rates were 42% and 36% for trabeculectomy and valve implantation, respectively. The success rates following the entire follow-up period were not significantly different between the two groups (p > 0.05 by log rank test). Postoperative complications occurred in 25% of the trabeculectomy-operated eyes and 9% of the Ahmed-implanted eyes (p = 0.38). There was no significant difference in surgical outcome between the trabeculectomy and Ahmed glaucoma valve implantation groups, neither of which had favorable results. However, the trabeculectomy group demonstrated a higher prevalence of adverse complications such as post-operative endophthalmitis.
Open heart surgery after renal transplantation.
Yamamura, Mitsuhiro; Miyamoto, Yuji; Mitsuno, Masataka; Tanaka, Hiroe; Ryomoto, Masaaki; Fukui, Shinya; Tsujiya, Noriko; Kajiyama, Tetsuya; Nojima, Michio
2014-09-01
to evaluate the strategy for open heart surgery after renal transplantation performed in a single institution in Japan. we reviewed 6 open heart surgeries after renal transplantation in 5 patients, performed between January 1992 and December 2012. The patients were 3 men and 2 women with a mean age of 60 ± 11 years (range 46-68 years). They had old myocardial infarction and unstable angina, aortic and mitral stenosis, left arterial myxoma, aortic stenosis, and native valve endocarditis followed by prosthetic valve endocarditis. Operative procedures included coronary artery bypass grafting, double-valve replacement, resection of left arterial myxoma, 2 aortic valve replacements, and a double-valve replacement. Renal protection consisted of steroid cover (hydrocortisone 100-500 mg or methylprednisolone 1000 mg) and intravenous immunosuppressant infusion (cyclosporine 30-40 mg day(-1) or tacrolimus 1.0 mg day(-1)). 5 cases were uneventful and good renal graft function was maintained at discharge (serum creatinine 2.1 ± 0.5 mg dL(-1)). There was one operative death after emergency double-valve replacement for methicillin-resistant Staphylococcus aureus-associated prosthetic valve endocarditis. Although the endocarditis improved after valve replacement, the patient died of postoperative pneumonia on postoperative day 45. careful perioperative management can allow successful open heart surgery after renal transplantation. However, severe complications, especially methicillin-resistant Staphylococcus aureus infection, may cause renal graft loss. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Combined PCI and minimally invasive heart valve surgery for high-risk patients.
Umakanthan, Ramanan; Leacche, Marzia; Petracek, Michael R; Zhao, David X; Byrne, John G
2009-12-01
Combined coronary artery valvular heart disease is a major cause of morbidity and mortality in the adult patient population. The standard treatment for such disease has been open heart surgery in which coronary artery bypass grafting (CABG) is performed concurrently with valve surgery using a median sternotomy and cardiopulmonary bypass. With the increasing complexity of patients referred to surgery, some patients may prove to be poor surgical candidates for combined valve and CABG surgery. In certain selected patients who fall into this category, valve surgery and percutaneous coronary intervention (PCI) have been considered a feasible alternative. Conventionally, valve surgery is performed in the cardiac surgical operating room, whereas PCI is carried out in the cardiac catheterization laboratory. Separation of these two procedural suites has presented a logistic limitation because it impedes the concomitant performance of both procedures in one setting. Hence, PCI and valve surgery usually have been performed as a "two-stage" procedure in two different operative suites, with the procedures being separated by hours, days, or weeks. Technologic advancements have made possible the construction of a "hybrid" procedural suite that combines the facilities of a cardiac surgical operating room with those of a cardiac catheterization laboratory. This design has enabled the concept of "one-stage" or "one-stop" PCI and valve surgery, allowing both procedures to be performed in a hybrid suite in one setting, separated by minutes. The advantages of such a method could prove to be multifold by enabling a less invasive surgical approach and improving logistics, patient satisfaction, and outcomes in selected patients.
VALVES FOR THE HIGH PRESSURE-HIGH TEMPERATURE (HP-HT) FLUORINATION SYSTEM. (Engineering Materials)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1963-10-31
This package contains two drawings of valves which eliminate errors in the gravimetric oxide dilution procedure of U/sup 235/ measurement. Isotopic contaminatioNonen in the high pressure fluorination reactor was corrected by changing the manner in which the Cu tubing joins the valve and by modification of the bellows. The compact inlet system was modified to improve the precision of the spectrometer analyses. Changes were raade in the basic leak and the air operator, which is a diaphragm-type valve, so that the setting of the flow level is controlled by the closure spring adjustment screw. This capillary-type leak has increased controlmore » range and sraooth control characteristics. It is simple to construct, is remotely operated and is free from corrosion failure. (F.S.)« less
Solenoid valve design minimizes vibration and sliding wear problem
NASA Technical Reports Server (NTRS)
Gillon, W. A., Jr.
1968-01-01
Two-way cryogenic solenoid valve resists damage from vibration and metallic interfacial sliding. The new system features a flat-faced armature guided by a flexure disk which eliminates sliding surfaces and is less subject to contamination and wear.
Reder, R F; Dimich, I; Steinfeld, L; Litwak, R S
1977-06-01
Operative relief of congenital tunnel subaortic stenosis by means of local incision or excision, or both, has generally been unsatisfactory. The use of a valve-bearing conduit between the left ventricular apex and thoracic aorta offers a predictable means of bypassing the left ventricular outflow obstruction. The procedure was used in a 17 year old girl with an excellent hemodynamic result. The history of operative management with diverting plantation of valved conduits in this position have not been defined, but use of these prostheses appears advisable in severe subvalvular, valvular and supravalvular obstructions that are not readily amenable to predictable and safe surgical palliation. The operation may prove useful in selected cases of idiopathic hypertrophic obstructive cardiomyopathy.
Minimally invasive aortic valve replacement surgery through lower half sternotomy
Fenton, James R.
2013-01-01
Less invasive approaches to aortic valve surgery frequently rely upon the development of new technology and instrumentation. While not suitable for every patient requiring an aortic valve procedure, these less invasive operations can offer certain clinical benefits and are becoming an important part of the modern cardiothoracic surgeon’s skillset. A lower partial sternotomy approach provides excellent visualization of the operative field, efficient execution of the operation and many of the benefits of minimally invasive surgery. Importantly, the lower partial sternotomy requires no new or unusual instruments and presents a familiar view to the surgeon. The technique, therefore, lends itself well to being adapted and utilized quickly with a potentially shorter “learning curve” for maximal surgical flexibility and patient benefit. PMID:24251024
Dielectric elastomer actuators used for pneumatic valve technology
NASA Astrophysics Data System (ADS)
Giousouf, Metin; Kovacs, Gabor
2013-10-01
Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications.
Stinson, W.J.
1958-09-16
A valve designed to selectively sample fluids from a number of sources is described. The valve comprises a rotatable operating lever connected through a bellows seal to a rotatable assembly containing a needle valve, bearings, and a rotational lock. The needle valve is connected through a flexible tube to the sample fluid outlet. By rotating the lever the needle valve is placed over . one of several fluid sources and locked in position so that the fluid is traasferred through the flexible tubing and outlet to a remote sampling system. The fluids from the nonselected sources are exhausted to a waste line. This valve constitutes a simple, dependable means of selecting a sample from one of several scurces.
Aortic valve ochronosis: a rare manifestation of alkaptonuria
Steger, Christina Maria
2011-01-01
Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed. PMID:22689837
Aortic valve ochronosis: a rare manifestation of alkaptonuria.
Steger, Christina Maria
2011-07-28
Alkaptonuric ochronosis is a heritable disorder of tyrosine metabolism, with various systemic abnormalities related to pigment deposition and degeneration of collagen and other tissues, including the heart and aorta. A 65-year-old woman with alkaptonuric ochronosis and a history of four joint replacements required aortic valve replacement for severe aortic stenosis. Operative findings included ochronosis of a partly calcified aortic valve and the aortic intima. The aortic valve was removed at surgery and histologically investigated. Light microscopic examination of the aortic valve revealed intracellular and extracellular deposits of ochronotic pigment and a chronic inflammatory infiltrate. Beside the case representation, the disease history, aetiology, pathogenesis, clinical presentation and treatment of aortic valve ochronosis are reviewed.
Note: An improved solenoid driver valve for miniature shock tubes.
Lynch, P T
2016-05-01
A solenoid driver valve has been built to improve the operating performance of diaphragmless shock tubes, which are used for high pressure, high temperature chemical kinetics, and fluid mechanics studies. For shock tube driver application, the most important characteristics are those of sealing, strength, and quality of the generated shock waves and repeatability of opening characteristics and therefore subsequent post-shock conditions. The main features of the new driver valve are a face o-ring sealing design of the valve, the large internal volume, and through inserts near the solenoid core: adjustable opening characteristics of the valve.
Simulations of Instabilities in Complex Valve and Feed Systems
NASA Technical Reports Server (NTRS)
Ahuja, Vineet; Hosangadi, Ashvin; Shipman, Jeremy; Cavallo, Peter A.
2006-01-01
CFD analyses are playing an increasingly important role in identifying and characterizing flow induced instabilities in rocket engine test facilities and flight systems. In this paper, we analyze instability mechanisms that range from turbulent pressure fluctuations due to vortex shedding in structurally complex valve systems to flow resonance in plug cavities to large scale pressure fluctuations due to collapse of cavitation induced vapor clouds. Furthermore, we discuss simulations of transient behavior related to valve motion that can serve as guidelines for valve scheduling. Such predictions of valve response to varying flow conditions is of crucial importance to engine operation and testing.
Design and operation of a fast electromagnetic inductive massive gas injection valve for NSTX-U.
Raman, R; Jarboe, T R; Nelson, B A; Gerhardt, S P; Lay, W-S; Plunkett, G J
2014-11-01
Results from the operation of an electromagnetic valve, that does not incorporate ferromagnetic materials, are presented. Image currents induced on a conducting disc placed near a pancake solenoid cause it to move away from the solenoid and open the vacuum seal. A new and important design feature is the use of Lip Seals for the sliding piston. The pressure rise in the test chamber is measured directly using a fast time response Baratron gauge. The valve injects over 200 Torr l of nitrogen in less than 3 ms, which remains unchanged at moderate magnetic fields.
Design and operation of a fast electromagnetic inductive massive gas injection valve for NSTX-U
NASA Astrophysics Data System (ADS)
Raman, R.; Jarboe, T. R.; Nelson, B. A.; Gerhardt, S. P.; Lay, W.-S.; Plunkett, G. J.
2014-11-01
Results from the operation of an electromagnetic valve, that does not incorporate ferromagnetic materials, are presented. Image currents induced on a conducting disc placed near a pancake solenoid cause it to move away from the solenoid and open the vacuum seal. A new and important design feature is the use of Lip Seals for the sliding piston. The pressure rise in the test chamber is measured directly using a fast time response Baratron gauge. The valve injects over 200 Torr l of nitrogen in less than 3 ms, which remains unchanged at moderate magnetic fields.
Hahs, Charles A.; Burbage, Charles H.
1984-01-01
The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.
40 CFR 63.175 - Quality improvement program for valves.
Code of Federal Regulations, 2010 CFR
2010-07-01
... improvement program for valves. (a) In Phase III, an owner or operator may elect to comply with one of the... use one of these alternative provisions to comply with the requirements of § 63.168(d)(1)(ii) of this... exceeds 2 percent leaking valves, and in such case, monthly monitoring will be required. (d) The following...
40 CFR 63.175 - Quality improvement program for valves.
Code of Federal Regulations, 2014 CFR
2014-07-01
... improvement program for valves. (a) In Phase III, an owner or operator may elect to comply with one of the... use one of these alternative provisions to comply with the requirements of § 63.168(d)(1)(ii) of this... exceeds 2 percent leaking valves, and in such case, monthly monitoring will be required. (d) The following...
Arterial switch: translocation of the intramural coronary artery.
Asou, T; Karl, T R; Pawade, A; Mee, R B
1994-02-01
Translocation of an intramural coronary artery is one of the most challenging problems in anatomic correction of transposition of the great arteries. Of 259 patients undergoing arterial switch procedure for transposition of the great arteries in our hospital, 12 (4.6%) were found to have intramural coronary arteries. The diagnosis was made intraoperatively in all patients. There were five different types of intramural coronary anatomy noted, with ostial stenosis present in half. The operative technique consisted of detachment of the posterior commissure of the aortic valve and unroofing of the intramural segment of the coronary artery by excision of a triangular portion of internal aortic wall. The coronary arteries were excised as a single disc, which was divided into two cuffs. The arterial switch was then performed in the usual fashion. The posterior commissure of the aortic valve was resuspended to the pericardial patch used to reconstruct the neopulmonary artery sinus. There were no operative or late deaths over a follow-up of 328 patient-months. Postoperatively, no patient showed ischemic changes on electrocardiogram or abnormal wall motion on echocardiogram. We believe that intramural coronary arteries can be managed satisfactorily with this technique, and that arterial switch will be possible in all cases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kern, J.J.
1978-01-01
The recently completed 800-mile trans-Alaska pipeline is reviewed from the perspective of its first six months of successful operation. Because of the many environmental and political constraints, the $7.7 billion project is viewed as a triumph of both engineering and capitalism. Design problems were imposed by the harsh climate and terrain and by the constant public and bureaucratic monitoring. Specifications are reviewed for the pipes, valves, river crossings, pump stations, control stations, and the terminal at Valdez, where special ballast treatment and a vapor-recovery system were required to protect the harbor's water and air quality. The article outlines operating proceduresmore » and contingency planning for the pipeline and terminal. (DCK)« less
Hansen, Kristoffer Lindskov; Møller-Sørensen, Hasse; Kjaergaard, Jesper; Jensen, Maiken Brit; Lund, Jens Teglgaard; Pedersen, Mads Møller; Lange, Theis; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann
2016-10-01
Stenosis of the aortic valve gives rise to more complex blood flows with increased velocities. The angle-independent vector flow ultrasound technique transverse oscillation was employed intra-operatively on the ascending aorta of (I) 20 patients with a healthy aortic valve and 20 patients with aortic stenosis before (IIa) and after (IIb) valve replacement. The results indicate that aortic stenosis increased flow complexity (p < 0.0001), induced systolic backflow (p < 0.003) and reduced systolic jet width (p < 0.0001). After valve replacement, the systolic backflow and jet width were normalized (p < 0.52 and p < 0.22), but flow complexity was not (p < 0.0001). Flow complexity (p < 0.0001), systolic jet width (p < 0.0001) and systolic backflow (p < 0.001) were associated with peak systolic velocity. The study found that aortic stenosis changes blood flow in the ascending aorta and valve replacement corrects some of these changes. Transverse oscillation may be useful for assessment of aortic stenosis and optimization of valve surgery. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Wilner, L.B.
1960-05-24
Explosive operated valves can be used to join two or more containers in fluid flow relationship, one such container being a sealed reservoir. The valve is most simply disposed by mounting it on the reservoir so thst a tube extends from the interior of the reservoir through the valve body, terminating at the bottom of the bore in a closed end; other containers may be similarly connected or may be open connected, as desired. The piston of the valve has a cutting edge at its lower end which shears off the closed tube ends and a recess above the cutting edge to provide a flow channel. Intermixing of the fluid being transferred with the explosion gases is prevented by a copper ring at the top of the piston which is force fitted into the bore at the beginning of the stroke. Although designed to avoid backing up of the piston at pressures up to 10,000 psi in the transferred fluid, proper operation is independent of piston position, once the tube ends were sheared.
Orthogonal optimization of a water hydraulic pilot-operated pressure-reducing valve
NASA Astrophysics Data System (ADS)
Mao, Xuyao; Wu, Chao; Li, Bin; Wu, Di
2017-12-01
In order to optimize the comprehensive characteristics of a water hydraulic pilot-operated pressure-reducing valve, numerical orthogonal experimental design was adopted. Six parameters of the valve, containing diameters of damping plugs, volume of spring chamber, half cone angle of main spool, half cone angle of pilot spool, mass of main spool and diameter of main spool, were selected as the orthogonal factors, and each factor has five different levels. An index of flowrate stability, pressure stability and pressure overstrike stability (iFPOS) was used to judge the merit of each orthogonal attempt. Embedded orthogonal process turned up and a final optimal combination of these parameters was obtained after totally 50 numerical orthogonal experiments. iFPOS could be low to a fairly low value which meant that the valve could have much better stabilities. During the optimization, it was also found the diameters of damping plugs and main spool played important roles in stability characteristics of the valve.
Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters
NASA Technical Reports Server (NTRS)
Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.
2015-01-01
It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since even 10(exp 9) cycles is well above anything demonstrated, this lower value was selected as the design point for the present work. The valve seal must remain leak-tight throughout operation, and the body must maintain a low internal leakage at relatively high operating temperatures. The full set of design requirements used for this program are summarized in Table 1. In this work, we describe two pulsed gas valves that have been fabricated to have long lifetime and demonstrate the characteristics listed above. The first is a miniaturized, conventional electromagnet-based valve while the second is a piezoelectric-based valve design. The conventional valve, shown in Fig. 1, is opened by use of a solenoid electromagnetic actuator. When current is applied to the solenoid coil, magnetic forces pull the plunger away from the valve seat, allowing fluid to flow through the valve. Removal of electrical current permits the spring and fluid pressure to seat the plunger, halting the flow of fluid. The valve body is fabricated from 304L corrosion resistant steel (CRES) and while the parts that form the magnetic circuit are fabricated from 430 CRES. This material does not have optimum magnetic properties, but its corrosion resistance permits incorporation into a design without requiring an additional plating process. A viton O-ring compound (Parker V0884-75), selected for its mechanical strength at elevated temperatures, was used for the valve seat seal. The design was based solely on the use of analytical sizing calculations, as opposed to a more rigorous finite element analysis. While this valve is small and relatively lightweight, it does not represent a design that is optimized for mass and/or a given volume envelope. The piezoelectric valve is a "puller" valve design. Applying a voltage to the piezo crystal causes it to elongate and pull a pintle off the seat, opening the valve. The valve seal consists of the pintle with an external, spherically-formed tip fabricated from Inconel 625 and the seat fabricated from Inconel 718 and possessing a spherical surface that permits the pintle to align with the valve body centerline after each cycle, maintaining the circumferential metal-on-metal seal. The contact stress on the valve pintle is expected in the worst case to be 96.5 MPa (14 ksi), which is well below the work hardening value of 413.7 MPa (60 ksi) for Inconel 615. Results presented in this work will compare the performance of each valve, both to each other and to the valve design requirements given in Table 1. In general, both valves meet all the performance envelope requirements, but the piezoelectric valve consumes considerably less power and has a faster response time over the conventional solenoid-driven valves.
Röck, T; Bartz-Schmidt, K-U; Röck, D; Yoeruek, E
2014-05-01
Currently, the main causes for developing bullous keratopathy are from problems related to intraocular surgery, trauma, infection, Fuchs' endothelial dystrophy and chronically elevated intraocular pressure. In the 1990s penetrating keratoplasty was once considered the therapy of choice for treatment of bullous keratopathy but in recent years it has been replaced by posterior lamellar keratoplasty. The Descemet membrane endothelial keratoplasty (DMEK) procedure represents the final development of posterior lamellar keratoplasty. The question now arises whether DMEK can be used in patients with bullous keratopathy and Ahmed glaucoma valve implant. A 72-year-old man was referred to our hospital for further evaluation with the diagnosis of bullous keratopathy and pseudoexfoliative glaucoma. The bullous keratopathy was caused by a variety of previous operations as well as decompensation of intraocular pressure. This article describes the therapy of bullous keratopathy by DMEK with existing Ahmed glaucoma valve implant. After surgery the cornea became clear and the best-corrected visual acuity improved from hand movement to 0.2. The intraocular pressure remained normal (10-14 mmHg) without antiglaucoma medication and the endothelial cell count decreased only slightly over a follow-up of 13 months. No complications were encountered. The DMEK surgical procedure seems to be possible in patients with Ahmed glaucoma valve implant and endothelial decompensation. However, further studies with a larger number of patients should follow to validate the replacement of penetrating keratoplasty and other posterior lamellar procedures by DMEK.
The importance of echocardiography in transcatheter aortic valve implantation.
Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin
2014-01-01
Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.
NASA Technical Reports Server (NTRS)
Berdahl, B. J.; Carle, G. C.; Oyama, V. I.
1971-01-01
Analyzer operates unattended or up to 15 hours. It has an automatic sample injection system and can be programmed. All fluid-flow valve switching is accomplished pneumatically from miniature three-way solenoid pilot valves.
Antimisting Fuel (AMK) Flight Degrader Development and Aircraft Fuel System Investigation
1987-02-01
Summary of Test Results 134 CV880 Support of the CID Mission 135 Comparison of the Pump/Degrader and Needle- Valve Degrader 146 Operation on Freshly Blended...Drain Valve 53 AM 33. View of Right Side of Number 3 Engine 54 34. Redundant Shutoff Valve 55 35. Bottom View of Number 3 Engine 55 36. Onboard...Supply and Regulation/Shutoff Valves 78 44. ATMP8O-1 Pump/Degrader Test Module 79 45. Fuel Flow Circuits 80 vii La LIST OF ILLUSTRATIONS (Continued
Combined effects of hydrazine exposure and endurance testing on solenoid-actuated valve performance
NASA Technical Reports Server (NTRS)
Hagler, R., Jr.
1974-01-01
Results are presented from a test program which was conducted to assess the capability of various solenoid-actuated valve design concepts to provide performance characteristics commensurate with long-duration (ten-year) missions to explore the outer planets. The valves were installed in a hydrazine flow test setup and periodically cycled during a nine-month test period under test conditions comparable to anticipated mission operating conditions. In situ valve performance was periodically determined, and leakage was continuously monitored.
2011-01-01
Objectives To retrospectively analyze the clinical outcome of a totally biological composite stentless aortic valved conduit (No-React® BioConduit) implanted using the Bentall procedure over ten years in a single centre. Methods Between 27/10/99 and 19/01/08, the No-React® BioConduit composite graft was implanted in 67 patients. Data on these patients were collected from the in-hospital database, from patient notes and from questionnaires. A cohort of patients had 2D-echocardiogram with an average of 4.3 ± 0.45 years post-operatively to evaluate valve function, calcification, and the diameter of the conduit. Results Implantation in 67 patients represented a follow-up of 371.3 patient-year. Males were 60% of the operated population, with a mean age of 67.9 ± 1.3 years (range 34.1-83.8 years), 21 of them below the age of 65. After a mean follow-up of 7.1 ± 0.3 years (range of 2.2-10.5 years), more than 50% of the survivors were in NYHA I/II and more than 60% of the survivors were angina-free (CCS 0). The overall 10-year survival following replacement of the aortic valve and root was 51%. During this period, 88% of patients were free from valved-conduit related complications leading to mortality. Post-operative echocardiography studies showed no evidence of stenosis, dilatation, calcification or thrombosis. Importantly, during the 10-year follow-up period no failures of the valved conduit were reported, suggesting that the tissue of the conduit does not structurally change (histology of one explant showed normal cusp and conduit). Conclusions The No-React® BioConduit composite stentless aortic valved conduit provides excellent long-term clinical results for aortic root replacement with few prosthesis-related complications in the first post-operative decade. PMID:21699696
[Tricuspid valve insufficiency: what should be done?].
von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G
1998-12-01
Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.
Incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery.
LaPietra, Angelo; Santana, Orlando; Mihos, Christos G; DeBeer, Steven; Rosen, Gerald P; Lamas, Gervasio A; Lamelas, Joseph
2014-07-01
Minimally invasive valve surgery has been associated with increased cerebrovascular complications. Our objective was to evaluate the incidence of cerebrovascular accidents in patients undergoing minimally invasive valve surgery. We retrospectively reviewed all the minimally invasive valve surgery performed at our institution from January 2009 to June 2012. The operative times, lengths of stay, postoperative complications, and mortality were analyzed. A total of 1501 consecutive patients were identified. The mean age was 73 ± 13 years, and 808 patients (54%) were male. Of the 1501 patients, 206 (13.7%) had a history of a cerebrovascular accident, and 225 (15%) had undergone previous heart surgery. The procedures performed were 617 isolated aortic valve replacements (41.1%), 658 isolated mitral valve operations (43.8%), 6 tricuspid valve repairs (0.4%), 216 double valve surgery (14.4%), and 4 triple valve surgery (0.3%). Femoral cannulation was used in 1359 patients (90.5%) and central cannulation in 142 (9.5%). In 1392 patients (92.7%), the aorta was clamped, and in 109 (7.3%), the surgery was performed with the heart fibrillating. The median aortic crossclamp and cardiopulmonary bypass times were 86 minutes (interquartile range [IQR], 70-107) minutes and 116 minutes (IQR, 96-143), respectively. The median intensive care unit length of stay was 47 hours (IQR, 29-74), and the median postoperative hospital length of stay was 7 days (IQR, 5-10). A total of 23 cerebrovascular accidents (1.53%) and 38 deaths (2.53%) had occurred at 30 days postoperatively. Minimally invasive valve surgery was associated with an acceptable stroke rate, regardless of the cannulation technique. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
[Initial experience of transcatheter implantation with a new aortic valve in sheep].
Wang, Jian-ming; Yang, Jian; Yang, Li-fang; Zhang, Xue-xin; Hu, Yun; Liu, Jin-cheng; Yu, Shi-qiang; Yi, Ding-hua
2011-11-01
To evaluate the feasibility and short-term results of transcatheter aortic valve implantation (TAVI) using a new transcatheter valve. Twenty healthy adult sheep received general anesthesia. Under the guidance of X-ray and transthoracic echocardiography (TTE), the new anti-calcification transcatheter valve was released from delivery system and implanted at the level of native aortic annulus via left common carotid artery. Position and function of the new anti-calcification transcatheter valve were evaluated by angiography and TTE immediately after intervention. Thirty day survival rate of animals was obtained. New transcatheter valves were implanted in all sheep. Fifteen sheep (75%) survived up to 30 days and post-operative examination showed that the transcatheter valve was in optimal position without migration and mitral valve impingement. The native coronary artery was patent in these animals. There was a slight paravalvular leak in 5 sheep. Postoperative echocardiography showed reflux percentage was significantly increased (P < 0.05) compared pre-intervention. Effective orifice area, aortic systolic pressure, diastolic aortic pressure, mean aortic pressure, left ventricular systolic pressure, left ventricular end diastolic pressure and heart rate were similar between post and pre-intervention (all P < 0.05). Five sheep died after TAVI within 30 days, including one fatal ventricular fibrillation occurred immediately after releasing the transcatheter valve and another sheep died of acute myocardial infarction due to left main coronary artery occlusion evidenced by angiography. Two sheep died of severe mitral regurgitation at 8 and 12 hours post-operation and one died of infective endocarditis at 26 days after intervention. Our favorable preliminary results showed that it was feasible to perform TAVI using the new transcatheter valve.
Upgrading the Control Systems of Turbines of K-160-12.8 Type Produced by PAO Turboatom
NASA Astrophysics Data System (ADS)
Babayev, I. N.
2018-05-01
Steam turbines of a K-160-12.8 (PVK-150) type produced by PAO Turboatom are operated at thermal power plants from the 1960s and many of them still have the complete set that was installed at that time by the factory, but they have become out of date. For this reason, the problem of upgrading the turbines to bring their characteristics into compliance with modern requirements is relevant. This article describes the main technical decisions adopted by PAO Turboatom when upgrading the automatic control system (ACS) of a K-160-12.8 (PVK-150) turbine: replacing the control valves (CV); replacing the distributing mechanism; replacing the front support components, including the main servomotor and oil control pipes; and replacing the assembly of cutoff spools by separate spools of servomotors of high-pressure control valves and reheat control valves. The schematic diagram of the ACS and description of the structure of newly installed mechanisms are presented: the cutoff spools, the high-pressure CVs, the distribution mechanism, and the main servomotor. The particularity of the ACS is the presence of electromechanical converters, which are used in each cutoff spool. For improving operating reliability of the ACS by providing the actuation of servomotors of control valves for closing regardless of ACS commands, the connection of rods of the electromechanical converter and cutoff spools are made using spring-type uncoupling devices. For actuation of the protection system by the commands of the automatic electronic safety device, the separate actuator driven by an electromagnet is installed in the ACS. During further improvement of the protection system, it is recommended to replace the controller assembly by two-spool protection devices, remove the protection spool assembly, and increase the pressure in the protection lines up to power pressure. The upgrading during this project was carried out by the Dobrotvor TPP (Ukraine).
A rare situation in acute rheumatic carditis: Involvement of all four valves.
Güvenç, Osman; Çimen, Derya
2017-01-01
Güvenç O, Çimen D. A rare situation in acute rheumatic carditis: Involvement of all four valves. Turk J Pediatr 2017; 59: 497-500. Acute rheumatic fever continues to be an important health problem, especially in countries that are socioeconomically underdeveloped. Carditis, which develops in approximately half of the patients, is responsible for both early-stage mortality as well as late-stage surgical treatment due to heart valve insufficiency or stenosis. The most frequent and severe valve involvement is with the mitral valve, while the aortic valve has the second highest incidence of involvement. Pulmonary and tricuspid valves are rarely involved. The literature cites a few adult cases in which all four valves are affected by rheumatic carditis; however, to the best of our knowledge, there have been no acute-stage rheumatic carditis pediatric cases reported. This article presents a 13-year-old male patient of Syrian origin who escaped to Turkey from the war in his country, and who was in the acute stage of rheumatic carditis in which all four valves were involved.
Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.
Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K
2018-01-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.
Valve leakage inspection, testing, and maintenance process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aikin, J.A.; Reinwald, J.W.
1989-01-01
Atomic Energy of Canada Limited-Research Company (AECL-RC), Chalk River, has more than 50 person-years dedicated toward the leak-free valve. In the early 1970s, the Chalk River Nuclear Laboratories (CRNL) developed valve stem live-loading and recently completed the packing tests for the Electric Power Research Institute (EPRI)-funded Valve Packing Improvement Study. Current safety concerns with asbestos-based valve packings and the difficulty in removing newer graphite packings prompted CRNL to investigate methods to improve valve repacking procedures. The present practice of valve packing replacement is very labor-intensive, requiring use of hand tools such as corkscrew devices and special packing picks. Use ofmore » water jets to cut or fragment the packing for withdrawal from the stuffing box does improve the process, but removal of the lantern or junk rings is still difficult. To address these problems, AECL-RC has developed a unique valve maintenance process designed to reduce person-rem exposures, the risk of scoring the stem or stuffing box, and maintenance costs and to improve the engineering quality of valve repair.« less
Hussain, Syed T; Majdalany, David S; Dunn, Aaron; Stewart, Robert D; Najm, Hani K; Svensson, Lars G; Houghtaling, Penny L; Blackstone, Eugene H; Pettersson, Gösta B
2018-02-01
Risk of reoperation and loss of a second native valve are major drawbacks of the Ross operation. Rather than discarding the failed autograft, it can be placed back into the native pulmonary position by "Ross reversal." We review our early and mid-term results with this operation. From 2006 to 2017, 39 patients underwent reoperation for autograft dysfunction. The autograft was successfully rescued in 35 patients: by Ross reversal in 30, David procedure in 4, and autograft repair in 1. Medical records were reviewed for patient characteristics (mean age was 46 ± 13 years, range 18-67 years, and 23 were male), previous operations, indications for reoperation, hospital outcomes, and echocardiographic findings for the 30 patients undergoing successful Ross reversal. Follow-up was 4.1 ± 3.5 years (range 7 months-11 years). Median interval between the original Ross procedure and Ross reversal was 12 years (range 5-19 years). Eight patients also had absolute indications for replacement of the pulmonary allograft. There was no operative mortality. One patient required reoperation for bleeding. Another had an abdominal aorta injury from use of an endoballoon clamp. There was no other major postoperative morbidity, and median postoperative hospital stay was 7.2 days (range 4-41 days). No patient required reoperation during follow-up. Twenty-four patients had acceptable pulmonary valve function, and 6 had clinically well-tolerated moderate or severe pulmonary regurgitation. Ross reversal can be performed with low morbidity and acceptable pulmonary valve function, reducing patient risk of losing 2 native valves when the autograft fails in the aortic position. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Magnetic-adhesive based valves for microfluidic devices used in low-resource settings.
Harper, Jason C; Andrews, Jenna M; Ben, Candice; Hunt, Andrew C; Murton, Jaclyn K; Carson, Bryan D; Bachand, George D; Lovchik, Julie A; Arndt, William D; Finley, Melissa R; Edwards, Thayne L
2016-10-18
Since the introduction of micro total analytical systems (μTASs), significant advances have been made toward development of lab-on-a-chip platforms capable of performing complex biological assays that can revolutionize public health, among other applications. However, use of these platforms in low-resource environments (e.g. developing countries) has yet to be realized as the majority of technologies used to control microfluidic flow rely on off-device hardware with non-negligible size, cost, power requirements and skill/training to operate. In this paper we describe a magnetic-adhesive based valve that is simple to construct and operate, and can be used to control fluid flow and store reagents within a microfluidic device. The design consists of a port connecting two chambers on different planes in the device that is closed by a neodymium disk magnet seated on a thin ring of adhesive. Bringing an external magnet into contact with the outer surface of the device unseats and displaces the valve magnet from the adhesive ring, exposing the port. Using this configuration, we demonstrate on-device reagent storage and on-demand transport and reaction of contents between chambers. This design requires no power or external instrumentation to operate, is extremely low cost ($0.20 materials cost per valve), can be used by individuals with no technical training, and requires only a hand-held magnet to actuate. Additionally, valve actuation does not compromise the integrity of the completely sealed microfluidic device, increasing safety for the operator when toxic or harmful substances are contained within. This valve concept has the potential to simplify design of μTASs, facilitating development of lab-on-a-chip systems that may be practical for use in point-of-care and low-resource settings.
NASA Technical Reports Server (NTRS)
Atwell, Matthew J.; Melcher, John C.; Hurlbert, Eric A.; Morehead, Robert L.
2017-01-01
A liquid oxygen, liquid methane (LOX/LCH4) reaction control system (RCS) was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under simulated altitude and thermal vacuum conditions. The RCS is a subsystem of the Integrated Cryogenic Propulsion Test Article (ICPTA) and was initially developed under Project Morpheus. Composed of two 28 lbf-thrust and two 7 lbf-thrust engines, the RCS is fed in parallel with the ICPTA main engine from four propellant tanks. 40 tests consisting of 1,010 individual thruster pulses were performed across 6 different test days. Major test objectives were focused on system dynamics, and included characterization of fluid transients, manifold priming, manifold thermal conditioning, thermodynamic vent system (TVS) performance, and main engine/RCS interaction. Peak surge pressures from valve opening and closing events were examined. It was determined that these events were impacted significantly by vapor cavity formation and collapse. In most cases the valve opening transient was more severe than the valve closing. Under thermal vacuum conditions it was shown that TVS operation is unnecessary to maintain liquid conditions at the thruster inlets. However, under higher heat leak environments the RCS can still be operated in a self-conditioning mode without overboard TVS venting, contingent upon the engines managing a range of potentially severe thermal transients. Lastly, during testing under cold thermal conditions the engines experienced significant ignition problems. Only after warming the thruster bodies with a gaseous nitrogen purge to an intermediate temperature was successful ignition demonstrated.
46 CFR 108.443 - Controls and valves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... valves. (a) At least one control for operating a CO2 system must be outside the space or spaces that the... also in the protected space. (b) A CO2 system that protects more than one space must have a manifold... protected space. (c) A CO2 system that protects only one space must have a stop valve installed between the...
McNeely, Christian A; Vassileva, Christina M
2015-01-01
The short-term advantage of mitral valve repair versus replacement for degenerative disease has been extensively documented. These advantages include lower operative mortality, improved survival, better preservation of left-ventricular function, shorter post-operative hospital stay, lower total costs, and fewer valve-related complications, including thromboembolism, anticoagulation-related bleeding events and late prosthetic dysfunction. More recent written data are available indicating the long-term advantage of repair versus replacement. While at some institutions, the repair rate for degenerative disease may exceed 90%, the national average in 2007 was only 69%. Making direct comparisons between mitral valve repair and replacement using the available studies does present some challenges however, as there are often differences in baseline characteristics between patient groups as well as other dissimilarities between studies. The purpose of this review is to systematically summarize the long-term survival and reoperation data of mitral valve repair versus replacement for degenerative disease. A PubMed search was done and resulted in 12 studies that met our study criteria for comparing mitral valve repair versus replacement for degenerative disease. A systematic review was then conducted abstracting survival and reoperation data. PMID:25158683
DOE Office of Scientific and Technical Information (OSTI.GOV)
HAMMERS, J.S.
1999-09-22
The purpose of the test was to verify that the AN Tank Farm Manifold Valves can be manually manipulated to the required operating position and that the electrical and visual indications accurately reflect that position. Physical locking devices were also verified to function. The Acceptance Test Procedure HNF-4642, 241-AN-A Valve Pit Manifold Valves and Position Indication was conducted between 23 June and 10 August 1999 at the 200E AN Tank Farm. The test has no open test exceptions. The test was conducted prior to final engineering ''as built'' activities being completed, this had an impact on the procedure and testmore » results, ECN 653752 was written to correct the mismatch between the procedure and actual field conditions. P&ID H-14-100941 was changed via ECN-W-314-4C-120. All components, identified in the procedure, were not found to be labeled and identified as written in the procedure, temporary tags were used for operational identification. A retest of valve ANA-WT-V 318 was required because it was removed from its installed position and modified after testing was completed.« less
Electrodynamic actuators for rocket engine valves
NASA Technical Reports Server (NTRS)
Fiet, O.; Doshi, D.
1972-01-01
Actuators, employed in acoustic loudspeakers, operate liquid rocket engine valves by replacing light paper cones with flexible metal diaphragms. Comparative analysis indicates better response time than solenoid actuators, and improved service life and reliability.
Urrea, M S; Herrera, V; Rey, A; Vargas, J
1993-01-01
Between 1 February 1992 and 1 March 1993, we performed Ross's aortic replacement in 7 men and 4 women with rheumatic heart disease. The patients' ages ranged from 22 to 60 years (mean, 41 years). All 11 patients had aortic valve disease; 2 also had mitral valve disease. In all patients, the right ventricular outflow tract was reconstructed using an autologous pericardial conduit containing a bovine cardiac valve bioprosthesis manufactured at our institution. The 2 patients who had mitral valve disease underwent a concomitant mitral valvuloplasty. In 1 patient, minimal aortic regurgitation was documented by means of transesophageal echocardiography immediately after the cessation of cardiopulmonary bypass, but no hemodynamic compromise was noted. In another patient, mediastinal exploration was required for bleeding, 3.5 hours postoperatively. The follow-up period ranged from 6 to 16 months (mean, 11.3 months). Results were assessed by means of clinical and transesophageal echocardiographic studies. No infection or technical failure was encountered. No patient died. All patients remain asymptomatic, and follow-up echocardiography has revealed no transaortic or transpulmonary gradient. The Ross operation was chosen for this group of patients because it avoids the use of mechanical valves and subsequent anticoagulant therapy. Most of our patients have a low income and a history of noncompliance with the strict postoperative drug regimen. Although the short-term results have been excellent with the Ross operation and our combination bioprosthesis, long-term evaluation is needed. PMID:8298323
Chi, Hao; Zhou, Wen-Xiong; Wu, Yao-Yao; Chen, Tong-Yu; Ge, Wen; Yuan, Lan; Shen, Wei-Dong; Zhou, Jia
2014-02-01
To determine whether electroacupuncture (EA) intervention combined with general anesthesia (GA) strategy can reduce early post-operative morbidity and medical costs in patients undergoing heart valve replacement operation under cardiopulmonary bypass. A total of 160 heart valve replacement surgery patients undergoing cardiopulmonary bypass were randomly divided into GA and EA + GA groups (n = 80 in each group). Patients of the GA group were given with intravenous injection of Fentanyl, Midazolam, Vecuronium Bromide, etc. and routine tracheal intubation. EA (3-4 Hz, 2.0-2.2 mA) was applied to bilateral Zhongfu (LU 1), Chize (LU 5) and Ximen (PC 4) beginning about 20 mm before the surgery in the EA + GA group. Endotracheal intubation was not employed but only prepared as a standby for patients of the EA + GA group. The dosage of narcotic drugs, duration of surgery, duration of aertic blockage, rate of cardiac re-beating, volumes of post-operative blood transfusion, discharge volume, cases of post-operative pulmonary infection, vocal cord injury, and the time of first bed-off, first eating and duration in intensive care unit (IOU) residence. etc. were recorded. The successful rates of heart valve replacement surgery were similar in both GA and EA + GA groups. Compared with the GA group, the dosages of Fentanyl, Midazolam and Vecuronium of the EA + GA group were significantly lower (P < 0.05, P < 0.01), the numbers of patients needing blood-transfusion, antibiotics treatment, and suffering from pulmonary infection were fewer, the time of first bed-off and duration of hospitalizetion and IOU residence were considerably shorter (P < 0.05, P < 0.01) and the total medical cost was obviously lower (P < 0.05) in the EA + GA group. EA combined with general anesthesia strategy for heart valve replacement surgery without endotracheal intubation is safe and can reduce post-operative morbidity and medical costs in patients undergoing heart valve replacement surgery under cardiopulmonary bypass.
NASA Technical Reports Server (NTRS)
Harris, Herbert B.; Duffy, Robert T.; Erwin, Robert D., Jr.
1945-01-01
A continuous 50-hour test was conducted to determine the effect of maximum cruise-power operation at ultra-lean fuel-air mixture and increased spark advance on the mechanical conditions of cylinder components. The test was conducted on a nine-cylinder air-cooled radial engine at the following conditions:brake horsepower, 750; engine speed, 1900 rpm; brake mean effective pressure, 172 pounds per square inch; fuel-air ratio, 0.052; spark advance, 30 deg B.T.C.; and maximum rear-spark-plug-bushing temperature, 400 F. In addition to the data on corrosion and wear, data are presented and briefly discussed on the effect of engine operation at the conditions of this test on economy, knock, preignition, and mixture distribution. Cylinder, piston, and piston-ring wear was small and all cylinder component were in good condition at the conclusion of the 50-hour test except that all exhaust-valve guides were bellmouthed beyond the Army's specified limit and one exhaust-valve face was lightly burned. It is improbable that the light burning in one spot of the valve face would have progressed further because the burn was filled with a hard deposit so that the valve face formed an unbroken seal and the mating seat showed no evidence of burning. The bellmouthing of the exhaust-valve guides is believed to have been a result of the heavy carbon and lead-oxide deposits, which were present on the head end of the guided length of the exhaust-valve stem. Engine operational the conditions of this test was shown to result In a fuel saving of 16.8 percent on a cooled-power basis as compared with operation at the conditions recommended for this engine by the Army Air Forces for the same power.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalaskar, Vickey B; Szybist, James P; Splitter, Derek A
In recent years a number of studies have demonstrated that boosted operation combined with external EGR is a path forward for expanding the high load limit of homogeneous charge compression ignition (HCCI) operation with the negative valve overlap (NVO) valve strategy. However, the effects of fuel composition with this strategy have not been fully explored. In this study boosted HCCI combustion is investigated in a single-cylinder research engine equipped with direct injection (DI) fueling, cooled external exhaust gas recirculation (EGR), laboratory pressurized intake air, and a fully-variable hydraulic valve actuation (HVA) valve train. Three fuels with significant compositional differences aremore » investigated: regular grade gasoline (RON = 90.2), 30% ethanol-gasoline blend (E30, RON = 100.3), and 24% iso-butanol-gasoline blend (IB24, RON = 96.6). Results include engine loads from 350 to 800 kPa IMEPg for all fuels at three engine speeds 1600, 2000, and 2500 rpm. All operating conditions achieved thermal efficiency (gross indicated efficiency) between 38 and 47%, low NOX emissions ( 0.1 g/kWh), and high combustion efficiency ( 96.5%). Detailed sweeps of intake manifold pressure (atmospheric to 250 kPaa), EGR (0 25% EGR), and injection timing are conducted to identify fuel-specific effects. The major finding of this study is that while significant fuel compositional differences exist, in boosted HCCI operation only minor changes in operational conditions are required to achieve comparable operation for all fuels. In boosted HCCI operation all fuels were able to achieve matched load-speed operation, whereas in conventional SI operation the fuel-specific knock differences resulted in significant differences in the operable load-speed space. Although all fuels were operable in boosted HCCI, the respective air handling requirements are also discussed, including an analysis of the demanded turbocharger efficiency.« less
Hillebrand, Julia; Hoffmeier, Andreas; Djie Tiong Tjan, Tonny; Sindermann, Juergen R; Schmidt, Christoph; Martens, Sven; Scherer, Mirela
2017-05-01
Left ventricular assist device (LVAD) implantation is a well-established therapy to support patients with end-stage heart failure. However, the operative procedure is associated with severe trauma. Third generation LVADs like the HeartWare assist device (HeartWare, Inc., Framingham, MA, USA) are characterized by enhanced technology despite smaller size. These devices offer new minimally invasive surgical options. Tricuspid regurgitation requiring valve repair is frequent in patients with the need for mechanical circulatory support as it is strongly associated with ischemic and nonischemic cardiomyopathy. We report on HeartWare LVAD implantation and simultaneous tricuspid valve reconstruction through minimally invasive access by partial upper sternotomy to the fifth left intercostal space. Four male patients (mean age 51.72 ± 11.95 years) suffering from chronic heart failure due to dilative (three patients) and ischemic (one patient) cardiomyopathy and also exhibiting concomitant tricuspid valve insufficiency due to annular dilation underwent VAD implantation and tricuspid valve annuloplasty. Extracorporeal circulation was established via the ascending aorta, superior vena cava, and right atrium. In all four cases the LVAD implantation and tricuspid valve repair via partial median sternotomy was successful. During the operative procedure, no conversion to full sternotomy was necessary. One patient needed postoperative re-exploration because of pericardial effusion. No postoperative focal neurologic injury was observed. New generation VADs are advantageous because of the possibility of minimally invasive implantation procedure which can therefore minimize surgical trauma. Concomitant tricuspid valve reconstruction can also be performed simultaneously through partial upper sternotomy. Nevertheless, minimally invasive LVAD implantation is a challenging operative technique. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Radiant energy receiver having improved coolant flow control means
Hinterberger, H.
1980-10-29
An improved coolant flow control for use in radiant energy receivers of the type having parallel flow paths is disclosed. A coolant performs as a temperature dependent valve means, increasing flow in the warmer flow paths of the receiver, and impeding flow in the cooler paths of the receiver. The coolant has a negative temperature coefficient of viscosity which is high enough such that only an insignificant flow through the receiver is experienced at the minimum operating temperature of the receiver, and such that a maximum flow is experienced at the maximum operating temperature of the receiver. The valving is accomplished by changes in viscosity of the coolant in response to the coolant being heated and cooled. No remotely operated valves, comparators or the like are needed.
Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae
2015-01-01
Purpose To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. Methods A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. Results The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9 mmHg in the Ahmed glaucoma valve implantation group (p = 0.73). The 48-month postoperative mean intraocular pressure was 19.6 mmHg in the trabeculectomy group and 20.2 mmHg in the Ahmed glaucoma valve implantation group (p = 0.95). The 12-month trabeculectomy success rate was 69%, compared with 64% for Ahmed glaucoma valve implantation, and the 48-month success rates were 42% and 36% for trabeculectomy and valve implantation, respectively. The success rates following the entire follow-up period were not significantly different between the two groups (p > 0.05 by log rank test). Postoperative complications occurred in 25% of the trabeculectomy-operated eyes and 9% of the Ahmed-implanted eyes (p = 0.38). Conclusions There was no significant difference in surgical outcome between the trabeculectomy and Ahmed glaucoma valve implantation groups, neither of which had favorable results. However, the trabeculectomy group demonstrated a higher prevalence of adverse complications such as post-operative endophthalmitis. PMID:25829827
NASA Technical Reports Server (NTRS)
Spanogle, J A; Whitney, E G
1931-01-01
An investigation was made to determine to what extent the rates of combustion in a compression-ignition engine can be controlled by varying the rates of fuel injection. The tests showed that the double-stem valve operated satisfactorily under all normal injection conditions; the rate of injection has a definite effect on the rate of combustion; the engine performance with the double-stem valve was inferior to that obtained with a single-stem valve; and the control of injection rates permitted by an injection valve of two stages of discharge is not sufficient to effect the desired rates of combustion.
Gafoor, Sameer; Petrescu, O Madalina; Lehr, Eric J; Puls, Charles; Zhang, Ming; Petersen, John L; Olsen, John V; Penev, Irina; Agrawal, Mayank; Sharma, Rahul; Barnhart, Glenn
2017-03-01
Patients who present with both severe mitral and tricuspid regurgitation who are symptomatic despite optimal medical therapy and at prohibitive risk for surgery pose a significant therapeutic challenge. The MitraClip device (Abbott Vascular) is approved for percutaneous mitral valve repair in high-risk and non-operative patients, and has also been used for tricuspid valve repair. Imaging support for percutaneous edge-to-edge tricuspid valve repair has not been reported and is a vital part of the procedure. Here, we present a periprocedural imaging strategy for percutaneous tricuspid valve repair with the MitraClip device using a bicuspidization technique.
Elective removal of convexo-concave Björk-Shiley valves.
Rajesh, P B; Smith, G H; Lawford, P V; Black, M M
1994-08-01
Replacement has been an accepted method for treating advanced cardiac valvular disease for more than 25 years. However, the perfect prosthesis has yet to be developed, judging by the number of devices available. A prosthesis that initially appears promising may cause problems in due course, and indeed some devices have been modified or withdrawn from clinical use. A notable example of a prosthetic valve that has give problems is the Björk-Shiley convexo-concave prosthesis, some models of which have undergone mechanical failure due to strut fracture. We report the elective removal of such a valve and the subsequent examination of the prosthesis. The results of this examination suggest that a policy of elective removal is justified.
Mvondo, Charles Mve; Pugliese, Marta; Giamberti, Alessandro; Chelo, David; Kuate, Liliane Mfeukeu; Boombhi, Jerome; Dailor, Ellen Marie
2016-01-01
Rheumatic valve disease, a consequence of acute rheumatic fever, remains endemic in developing countries in the sub-Saharan region where it is the leading cause of heart failure and cardiovascular death, involving predominantly a young population. The involvement of the mitral valve is pathognomonic and mitral surgery has become the lone therapeutic option for the majority of these patients. However, controversies exist on the choice between valve repair or prosthetic valve replacement. Although the advantages of mitral valve repair over prosthetic valve replacement in degenerative mitral disease are well established, this has not been the case for rheumatic lesions, where the use of prosthetic valves, specifically mechanical devices, even in poorly compliant populations remains very common. These patients deserve more accurate evaluation in the choice of the surgical strategy which strongly impacts the post-operative outcomes. This report discusses the factors supporting mitral repair surgery in rheumatic disease, according to the patients' characteristics and the effectiveness of the current repair techniques compared to prosthetic valve replacement in developing countries.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jukkola, Glen D.; Teigen, Bard C.
Disclosed herein is a solids flow control valve comprising a standpipe; a shoe; and a transport pipe; wherein the standpipe is in operative communication with the shoe and lies upstream of the shoe; the standpipe comprising a first end and a second end, where the first end is in contact with a source that contains disposable solids and the second end is in fluid contact with the shoe; the shoe being operative to restrict the flow of the disposable solids; the transport pipe being disposed downstream of the shoe to receive and transport the solids from the shoe.
The oil pressure test of the hydraulic impeller blade
NASA Astrophysics Data System (ADS)
Ye, Wen-bo; Jia, Li-tao
2017-12-01
This article introduced the structure of the Kaplan runner in hydropower station and the operating process of the oil pressure test has been described. What’s more, the whole process, including filling oil to the runner hub, the movement of the runner blade, the oil circuit, have been presented in detail.Since the manipulation of the oil circuit which controlled by three Valve groups consisting of six valves was complicated, the author is planning to replace them with 3-position 3-way electromagnetic valves, so we can simplify the operation procedure.The author hopes this article can provide technical reference for the oil pressure test.
A WEAR MODEL FOR DIESEL ENGINE EXHAUST VALVES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blau, Peter Julian
2009-11-01
The work summarized here comprises the concluding effort of a multi-year project, funded by the U.S. Department of Energy, Office of Vehicle Technologies. It supports the development of a better understanding of advanced diesel engine designs in which enhanced power density, energy efficiency, and emissions control place increasing demands upon the durability of engine materials. Many kinds of metallic alloys are used in engines depending on the operating stresses, temperatures, and chemical environments. Exhaust valves, for example, are subjected to high temperatures and repetitive surface contacts that place demands on durability and frictional characteristics of the materials. Valves must continuemore » to seal the combustion chamber properly for thousands of hours of cyclic engine operation and under varying operating conditions. It was the focus of this effort to understand the wear processes in the valve-seat area and to develop a model for the surface deformation and wear of that important interface. An annotated bibliography is provided to illustrate efforts to understand valve wear and to investigate the factors of engine operation that affect its severity and physical manifestation. The project for which this modeling effort was the final task, involved construction of a high-temperature repetitive impact test system as well as basic tribology studies of the combined processes of mechanical wear plus oxidation at elevated temperatures. Several publications resulted from this work, and are cited in this report. The materials selected for the experimental work were high-performance alloys based on nickel and cobalt. In some cases, engine-tested exhaust valves were made available for wear analysis and to ensure that the modes of surface damage produced in experiments were simulative of service. New, production-grade exhaust valves were also used to prepare test specimens for experimental work along with the other alloy samples. Wear analysis of valves and seats run for hundreds of hours in heavy-duty diesels provided insights into the kinds of complexity that the contact conditions in engines can produce, and suggested the physical basis for the current approach to modeling. The model presented here involves four terms, two representing the valve response and two for its mating seat material. The model's structure assumes that wear that takes place under a complex combination of plastic deformation, tangential shear, and oxidation. Tribolayers form, are removed, and may reform. Layer formation affects the friction forces in the interface, and in turn, the energy available to do work on the materials to cause wear. To provide friction data for the model at various temperatures, sliding contact experiments were conducted from 22 to 850 C in a pin-on-disk apparatus at ORNL. In order to account for the behavior of different materials and engine designs, parameters in all four terms of the model can be adjusted to account for wear-in and incubation periods before the dominant wear processes evolve to their steady-state rates. For example, the deformation rate is assumed to be maximum during the early stages of operation, and then, due to material work-hardening and the increase in nominal contact area (which reduces the load per unit area), decreases to a lower rate at long times. Conversely, the rate of abrasion increases with time or number of cycles due to the build-up of oxides and tribo-layers between contact surfaces. The competition between deformation and abrasion results in complex, non-linear behavior of material loss per cycle of operation. Furthermore, these factors are affected by valve design features, such as the angle of incline of the valve seat. Several modeling scenarios are presented to demonstrate how the wear profile versus number of cycles changes in response to: (a) different relative abrasion rates of the seat and valve materials, (b) the friction coefficient as a function of temperature, (c) the relative deformation contribution of valve and seat materials, and (d) an interruption in the dominant wear process.« less
Olivieri, Laura J.; Baba, Ridhwan Y.; Arai, Andrew E.; Bandettini, W. Patricia; Rosing, Douglas R.; Bakalov, Vladimir; Sachdev, Vandana; Bondy, Carolyn A.
2014-01-01
Background Congenital aortic valve fusion is associated with aortic dilation, aneurysm and rupture in girls and women with Turner syndrome (TS). Our objective was to characterize aortic valve structure in subjects with TS, and determine the prevalence of aortic dilation and valve dysfunction associated with different types of aortic valves. Methods and Results The aortic valve and thoracic aorta were characterized by cardiovascular magnetic resonance imaging in 208 subjects with TS in an IRB-approved natural history study. Echocardiography was used to measure peak velocities across the aortic valve, and the degree of aortic regurgitation. Four distinct valve morphologies were identified: tricuspid aortic valve (TAV) 64%(n=133), partially fused aortic valve (PF) 12%(n=25), bicuspid aortic valve (BAV) 23%(n=47), and unicuspid aortic valve (UAV) 1%(n=3). Age and body surface area (BSA) were similar in the 4 valve morphology groups. There was a significant trend, independent of age, towards larger BSA-indexed ascending aortic diameters (AADi) with increasing valve fusion. AADi were (mean +/− SD) 16.9 +/− 3.3 mm/m2, 18.3 +/− 3.3 mm/m2, and 19.8 +/− 3.9 mm/m2 (p<0.0001) for TAV, PF and BAV+UAV respectively. PF, BAV, and UAV were significantly associated with mild aortic regurgitation and elevated peak velocities across the aortic valve. Conclusions Aortic valve abnormalities in TS occur with a spectrum of severity, and are associated with aortic root dilation across age groups. Partial fusion of the aortic valve, traditionally regarded as an acquired valve problem, had an equal age distribution and was associated with an increased AADi. PMID:24084490
Aortic root surgery in the United States: a report from the Society of Thoracic Surgeons database.
Stamou, Sotiris C; Williams, Mathew L; Gunn, Tyler M; Hagberg, Robert C; Lobdell, Kevin W; Kouchoukos, Nicholas T
2015-01-01
The purpose of the present study was to evaluate the early clinical outcomes of aortic root surgery in the United States. The Society of Thoracic Surgeons database was queried to identify all patients who had undergone aortic root replacement from 2004 to early 2010 (n = 13,743). The median age was 58 years (range, 18-96); 3961 were women (29%) and 12,059 were white (88%). The different procedures included placement of a mechanical valve conduit (n = 4718, 34%), stented pericardial (n = 879, 6.4%) or porcine (n = 478, 3.5%) bioprosthesis, stentless root (n = 4309, 31%), homograft (n = 498, 3.6%), and valve sparing root replacement (n = 1918, 14%). The median number of aortic root surgeries per site was 2, and only 5% of sites performed >16 aortic root surgeries annually. An increased trend to use biostented (porcine or pericardial) valves during the study period (7% in 2004 vs 14% in 2009). The operative (raw) mortality was greater among the patients with aortic stenosis (6.2%) who had undergone aortic root replacement, independent of age. Mortality was greater in patients who had undergone concomitant valve or coronary artery bypass grafting or valve surgery (21%). The lowest operative mortality was observed in patients who had undergone aortic valve sparing procedures (1.9%). Most cardiac centers performed aortic root surgery in small volumes. The unadjusted operative mortality was greater for patients >80 years old and those with aortic stenosis, regardless of age. Valve sparing root surgery was associated with the lowest mortality. A trend was seen toward an increased use of stented tissue valves from 2004 to 2009. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters
NASA Technical Reports Server (NTRS)
Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.
2015-01-01
The design and test results for two types of pulsed gas valves are presented. The valves, a piezo valve and a solenoid actuated valve, must have exceedingly long lifetime to support gas-fed pulsed electric thruster operation for missions of interest. The performance of both valves was tested, with both demonstrating the capability to throttle the gas flow rate while maintaining low leakage levels below 10(exp -3) sccs of He at the beginning of valve lifetime. The piezo valve varies the flow rate by changing the amount that the valve is open, which is a function of applied voltage. This valve demonstrated continuous throttlability from 0-10 mL/s, with opening and closing times of 100 microsecond or less. The solenoid actuated valve flow rate changes as a function of the inlet gas pressure, with demonstrated flow rates in these tests from 2.7-11 mL per second. The valve response time is slower than the piezo valve, opening in 1-2 ms and closing in several ms. The solenoid actuated valve was tested to one million cycles, with the valve performance remaining relatively unchanged throughout the test. Galling of the sliding plunger caused the valve to bind and fail just after one million cycles, but at this point in the test the valve sealing surface leak rate still appeared to be well below the maximum target leak rake of 1×10(exp -3) sccs of He.
NASA Technical Reports Server (NTRS)
Acres, R. L.
1972-01-01
Design and development of two types of pumps for handling liquefied gases are discussed. One pump uses mechanical valve shift and other uses pneumatic valve shift. Illustrations of pumps are provided and detailed description of operation is included.
The Ross operation: the autologous pulmonary valve in the aortic position.
Gonzalez-Lavin, L; Robles, A; Graf, D
1988-03-01
Aortic valve replacement (AVR) with a pulmonary valve autograft (PVA) was first reported by Donald N. Ross (DNR) in 1967. The expectation of this procedure was to avoid degenerative changes seen in other biological tissue valves such as calcification, attenuation, and rupture of the leaflets. Recent reports by the original investigator's group have confirmed the lack of degenerative changes in PVA. To corroborate their conclusions, the fate of 12 patients undergoing AVR with PVA by one of us (LGL) has been ascertained. From March 1969 to June 1971, 12 patients underwent AVR with PVA. The right ventricular outflow tract (RVOT) was reconstructed with an aortic homograft valved conduit. The mean age was 42.7 years (range 21 to 52 years). The mean follow-up for 11 hospital survivors is 12.4 years. Three PVA have been replaced; one following infective endocarditis at 13 years, and two at 15 and 73 months due to technical malalignment. There was no evidence of PVA degeneration during histological examination of these explanted PVAs. Six patients are alive and retain the original PVA at 12 years (55%). This analysis corroborates the conclusions of the DNR report and strongly suggests an immunological mechanism in the process of calcification of other biological tissue valves. The Ross operation is advocated for AVR in young patients as valve durability is of paramount importance especially in this group.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Leakage Tests for Cargo Tanks Transporting Liquefied Compressed Gases B Appendix B to Part 180... Pt. 180, App. B Appendix B to Part 180—Acceptable Internal Self-closing Stop Valve Leakage Tests for.... (b) Internal Self-Closing Stop Valve Test. An operator of a cargo tank that is not equipped with a...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2012 CFR
2012-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2014 CFR
2014-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2011 CFR
2011-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2013 CFR
2013-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.483-2a - Alternative standards for valves-skip period leak detection and repair.
Code of Federal Regulations, 2010 CFR
2010-07-01
.../vapor and light liquid service. (4) If the percent of valves leaking is greater than 2.0, the owner or... Industry for Which Construction, Reconstruction, or Modification Commenced After November 7, 2006 § 60.483... percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Standards: Valves in gas/vapor service...
40 CFR 60.482-7 - Standards: Valves in gas/vapor service and in light liquid service.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Before November 7, 2006 § 60.482-7 Standards: Valves in gas/vapor service and in light liquid service. (a... operation in gas/vapor service or light liquid service after the initial startup date for the process unit... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Standards: Valves in gas/vapor service...
System for detecting operating errors in a variable valve timing engine using pressure sensors
Wiles, Matthew A.; Marriot, Craig D
2013-07-02
A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.
Murakami, T
1989-05-01
Extracardiac conduits, such as Dacron or homo-graft, have been utilized for the operative management of many patients with congenital right ventricular outflow obstruction. However, they have been recognized to become obstructed or calcified with time. As a new material for extracardiac conduit, an original valved conduit using glutaraldehyde-preserved equine pericardium (Xenomedica) was investigated. Various types of valved conduit were evaluated for the hydrodynamics by a circulation system. A flow-pressure gradient Lissajous was used for the evaluation. The conduit of 10 mm in diameter had a high resistance to flow. The monocusp-valved conduit had a diastolic regurgitation (DR) at any given pressures and heart rates. The bicusp-valved conduit had a DR at higher heart rates (greater than 153/min). In this experiment, the tricusp-valved conduit with a valvular vertical versus horizontal length ratio of 2:3 had utmost favorable results under any given conditions. The valved conduits were also evaluated using sixteen mongrel dogs in which the conduit were used for the reconstruction of continuity between right ventricle and pulmonary artery. Five dogs died of bacterial infection or thrombotic obstruction. Following hemodynamic studies, which were performed in eleven dogs 1, 6, and 12 months after the operation, the dogs were sacrificed to evaluate the histological changes in the conduits. The valvular function had been satisfactory until one month, however, it was lost in 6 months because the valvular leaflets were covered with neointimae grown over them. Thin neointimae were observed both at the sites of anastomosis and at the base of the valves in dogs sacrificed at one month. They spread from the proximal anastomotic site to distal one. They were organized and it was hard to remove them manually. Thrombi were found in six dogs at the proximal anastomotic site with intimal hyperplasia. There was no calcification in Xenomedica and its degenerative change was minimal. In conclusion, the equine pericardium valved conduit is thought to be an useful material for the reconstruction of right ventricular outflow obstruction to improve early hemodynamic changes after operation.
Recently patented transcatheter aortic valves in clinical trials.
Neragi-Miandoab, Siyamek; Skripochnik, Edvard; Salemi, Arash; Girardi, Leonard
2013-12-01
The most widely used heart valve worldwide is the Edwards Sapien, which currently has 60% of the worldwide transcatheter aortic valve implantation (TAVI) market. The CoreValve is next in line in popularity, encompassing 35% of the worldwide TAVI market. Although these two valves dominate the TAVI market, a number of newer transcatheter valves have been introduced and others are in early clinical evaluation. The new valves are designed to reduce catheter delivery diameter, improve ease of positioning and sealing, and facilitate repositioning or removal. The most recent transcatheter valves for transapical use include Acurate TA (Symetis), Engager (Medtronic), and JenaValve the Portico (St Jude), Sadra Lotus Medical (Boston Scientific), and the Direct Flow Medical. These new inventions may introduce more effective treatment options for high-risk patients with severe aortic stenosis. Improvements in transcatheter valves and the developing variability among them may allow for more tailored approaches with respect to patient's anatomy, while giving operators the opportunity to choose devices they feel more comfortable with. Moreover, introducing new devices to the market will create a competitive environment among producers that will reduce high prices and expand availability. The present review article includes a discussion of recent patents related to Transcatheter Aortic Valves.
Development of Overflow-Prevention Valve with Trigger Mechanism.
NASA Astrophysics Data System (ADS)
Ishino, Yuji; Mizuno, Takeshi; Takasaki, Masaya
2016-09-01
A new overflow-prevention valve for combustible fluid is developed which uses a trigger mechanism. Loading arms for combustible fluid are used for transferring oil from a tanker to tanks and vice versa. The loading arm has a valve for preventing overflow. Overflow- prevention valves cannot use any electric component to avoid combustion. Therefore, the valve must be constructed only by mechanical parts. The conventional overflow-prevention valve uses fluid and pneumatic forces. It consists of a sensor probe, a cylinder, a main valve for shutting off the fluid and a locking mechanism for holding an open state of the main valve. The proposed overflow-prevention valve uses the pressure due to the height difference between the fluid level of the tank and the sensor probe. However, the force of the cylinder produced by the pressure is too small to release the locking mechanism. Therefore, a trigger mechanism is introduced between the cylinder and the locking mechanism. The trigger mechanism produces sufficient force to release the locking mechanism and close the main valve when the height of fluid exceeds a threshold value. A trigger mechanism is designed and fabricated. The operation necessary for closing the main valve is conformed experimentally.
An augmented magnetic navigation system for Transcatheter Aortic Valve Implantation.
Luo, Zhe; Cai, Junfeng; Nie, Yuanyuan; Wang, Guotai; Gu, Lixu
2013-01-01
This research proposes an augmented magnetic navigation system for Transcatheter Aortic Valve Implantation (TAVI) employing a magnetic tracking system (MTS) combined with a dynamic aortic model and intra-operative ultrasound (US) images. The dynamic 3D aortic model is constructed based on the preoperative 4D computed tomography (CT), which is animated according to the real time electrocardiograph (ECG) input of patient. And a preoperative planning is performed to determine the target position of the aortic valve prosthesis. The temporal alignment is performed to synchronize the ECG signals, intra-operative US image and tracking information. Afterwards, with the assistance of synchronized ECG signals, the contour of aortic root automatic extracted from short axis US image is registered to the dynamic aortic model by a feature based registration intra-operatively. Then the augmented MTS guides the interventionist to confidently position and deploy the aortic valve prosthesis to target. The system was validated by animal studies on three porcine subjects, the deployment and tilting errors of which are 3.17 ± 0.91 mm and 7.40 ± 2.89° respectively.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothberg, O.
1988-06-01
NRC regulatory positions, as stated in Regulatory Guide 1.106, Revision 1, have been identified by the Office for Analysis and Evaluation of Operational Data (AEOD) as potential contributors to valve motor burnout. AEOD is particularly concerned about the allowed policy of bypassing thermal overload devices during normal or accident conditions. Regulatory Guide 1.106 favors compromising the function of thermal overload devices in favor of completing the safety-related action of valves. The purpose of this study was to determine if the guidance contained in Regulatory Guide 1.106 is appropriate and, if not, to recommend the necessary changes. This report describes thermalmore » overload devices commonly used to protect safety-related valve operator motors. The regulatory guidelines stated in Regulatory Guide 1.106 along with the limitations of thermal overload protection are discussed. Supplements and alternatives to thermal overload protection are also described. Findings and conclusions of several AEOD reports are discussed. Information obtained from the standard review plan, standard technical specifications, technical specifications from representative plants, and several papers are cited.« less
Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi
2013-09-01
A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.
Percutaneous Pulmonary Valve Placement
Prieto, Lourdes R.
2015-01-01
Patients with congenital heart disease and pulmonary valve disease need multiple procedures over their lifetimes to replace their pulmonary valves. Chronic pulmonary stenosis, regurgitation, or both have untoward effects on ventricular function and on the clinical status of these patients. To date, all right ventricle–pulmonary artery conduits have had relatively short lifespans. Percutaneous pulmonary valve implantation, although relatively new, will probably reduce the number of operative procedures that these patients will have to undergo over a lifetime. Refinement and further development of this procedure holds promise for the extension of this technology to other patient populations. PMID:26175629
Shields, W.R.
1960-10-18
An improved valve is described for precisely regulating the flow of a sample fluid to be analyzed, such as in a mass spectrometer, where a gas sample is allowed to "leak" into an evacuated region at a very low, controlled rate. The flow regulating valve controls minute flow of gases by allowing the gas to diffuse between two mating surfaces. The structure of the valve is such as to prevent the corrosive feed gas from contacting the bellows which is employed in the operation of the valve, thus preventing deterioration of the bellows.
NASA Technical Reports Server (NTRS)
1981-01-01
Manufacturer of the Model 2210 copying machine was looking for a plastic valve bushing material that could be produced by a low-cost injection molding process to replace the unsuitable valve bushing they were using. NERAC conducted a computer search of the NASA database and was able to supply Nashua Corporation with several technical reports in their area of interest. Information aided the company's development of a urethane valve bushing which solved the problem and created a dramatic reduction in unit cost.
Design and analysis of a new high frequency double-servo direct drive rotary valve
NASA Astrophysics Data System (ADS)
Zhu, Muzhi; Zhao, Shengdun; Li, Jingxiang
2016-12-01
Researchers have investigated direct drive valve for many years to solve problems, such as fluid force imbalance and switching frequency. The structure of the rotary valve has received considerable research interest because of its favorable dynamic properties and simple structure. This paper studied the high frequency doubleservo direct drive rotary valve (DDRV), and proposed a novel structure and drive method satisfying high reversing frequency and adequate quantity of flow. Servo motors are integrated into the valve by the innovative structure, which is designed to equilibrate the unbalanced radial fluid force with the symmetric distributed oil ports. Aside from the fast reversing function of the valve, the DDRV presented high performance in linearity of the flow quantity and valve opening as a result of the fan-shaped flow ports. In addition, a computational fluid dynamics (CFD) method based on Fluent was conducted to verify the flux regulation effect of the height change of the adjustable boss.
Variable-pulse switching circuit accurately controls solenoid-valve actuations
NASA Technical Reports Server (NTRS)
Gillett, J. D.
1967-01-01
Solid state circuit generating adjustable square wave pulses of sufficient power operates a 28 volt dc solenoid valve at precise time intervals. This circuit is used for precise time control of fluid flow in combustion experiments.
The application of S-transformation and M-2DPCA in I.C. Engine fault diagnosis
NASA Astrophysics Data System (ADS)
Zhang, Shixiong; Cai, Yanping; Mu, Weijie
2017-04-01
According to the problem of parameter selection and feature extraction for vibration diagnosis of traditional internal combustion engine is discussed. The method based on S-transformation and Module Two Dimensional Principal Components Analysis (M-2DPCA) is proposed to carry out fault diagnosis of I.C. Engine valve mechanism. First of all, the method transfers cylinder surface vibration signals of I.C. into images through S-transform. The second, extracting the optimized projection vectors from the general distribution matrix G which is obtained by all sample sub-images, so that vibration spectrum images can be modularized using M-2DPCA. The last, these features matrix obtained from images project will served as the enters of nearest neighbor classifier, it is used to achieve fault types' division. The method is applied to the diagnosis example of the vibration signal of the valve mechanism eight operating modes, recognition rate up to 94.17 percent; the effectiveness of the proposed method is proved.
NASA Astrophysics Data System (ADS)
Shabliy, L. S.; Malov, D. V.; Bratchinin, D. S.
2018-01-01
In the article the description of technique for simulation of valves for pneumatic-hydraulic system of liquid-propellant rocket engine (LPRE) is given. Technique is based on approach of computational hydrodynamics (Computational Fluid Dynamics - CFD). The simulation of a differential valve used in closed circuit LPRE supply pipes of fuel components is performed to show technique abilities. A schematic and operation algorithm of this valve type is described in detail. Also assumptions made in the construction of the geometric model of the hydraulic path of the valve are described in detail. The calculation procedure for determining valve hydraulic characteristics is given. Based on these calculations certain hydraulic characteristics of the valve are given. Some ways of usage of the described simulation technique for research the static and dynamic characteristics of the elements of the pneumatic-hydraulic system of LPRE are proposed.
Indication for percutaneous aortic valve implantation
Akin, Ibrahim; Kische, Stephan; Rehders, Tim C.; Nienaber, Christoph A.; Rauchhaus, Mathias; Schneider, Henrik; Liebold, Andreas
2010-01-01
The incidence of valvular aortic stenosis has increased over the past decades due to improved life expectancy. Surgical aortic valve replacement is currently the only treatment option for severe symptomatic aortic stenosis that has been shown to improve survival. However, up to one third of patients who require lifesaving surgical aortic valve replacement are denied surgery due to high comorbidities resulting in a higher operative mortality rate. In the past such patients could only be treated with medical therapy or percutaneous aortic valvuloplasty, neither of which has been shown to improve mortality. With advances in interventional cardiology, transcatheter methods have been developed for aortic valve replacement with the goal of offering a therapeutic solution for patients who are unfit for surgical therapy. Currently there are two catheter-based treatment systems in clinical application (the Edwards SAPIEN aortic valve and the CoreValve ReValving System), utilizing either a balloon-expandable or a self-expanding stent platform, respectively. PMID:22371763
[Longterm results of mitral valve replacement (author's transl)].
Erhard, W; Reichmann, M; Delius, W; Sebening, H; Herrmann, G
1977-04-22
210 patients were followed up by the actuary method for over 5 years after isolated mitral valve replacement or a double valve replacement. After isolated valve replacement the one month survival including the operative mortality was 92+/-2%. The survival after one year was 83+/-3% and after 5 years 66+/-7%. The five year survival of patients in preoperative class III (according to the NYHA) was 73+/-8% and of class IV 57+/-8% (P less than or equal to 0.1). A comparison of valve replacements for pure mitral stenosis or mitral insufficiency showed no statistically significant differences. In the 37 patients who had a double valve replacement the survival risk was not increased in comparison with those patients who had had a single valve replacement. Age above 45 years and a preoperative markedly raised pulmonary arteriolar resistance reduced the chances of survival.
González-Santos, Jose María; Arnáiz-García, María Elena; Dalmau-Sorlí, María José; Sastre-Rincón, Jose Alfonso; Hernández-Hernández, Jesús; Pérez-Losada, María Elena; Sagredo-Meneses, Víctor; López-Rodríguez, Javier
2016-10-01
A patient who underwent previous implantation of a mitral valve replacement with a Björk-Shiley Delrin (BSD) mitral valve prosthesis during infancy was admitted to our institution 43 years later after an episode of syncope and cardiac arrest. Under extreme hemodynamic instability, a mitral valve prosthetic dysfunction causing massive mitral regurgitation was identified. The patient underwent an emergent cardiac operation, and a complete disc fracture with partial disc migration was found. Exceptional cases of mechanical prosthetic heart valve fracture exist. We report the first case of complete transversal disc rupture of a BSD mitral valve prosthesis after the longest period of implantation ever reported in that position. Copyright © 2016 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
Novel liquid equilibrium valving on centrifugal microfluidic CD platform.
Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Arof, Hamzah; Madou, Marc
2013-01-01
One of the main challenges faced by researchers in the field of microfluidic compact disc (CD) platforms is the control of liquid movement and sequencing during spinning. This paper presents a novel microfluidic valve based on the principle of liquid equilibrium on a rotating CD. The proposed liquid equilibrium valve operates by balancing the pressure produced by the liquids in a source and a venting chamber during spinning. The valve does not require external forces or triggers, and is able to regulate burst frequencies with high accuracy. In this work, we demonstrate that the burst frequency can be significantly raised by making just a small adjustment of the liquid height in the vent chamber. Finally, the proposed valve ng method can be used separately or combined with other valving methods in advance microfluidic processes.
NASA Astrophysics Data System (ADS)
Wang, Dongyang; Ba, Dechun; Hao, Ming; Duan, Qihui; Liu, Kun; Mei, Qi
2018-05-01
Pneumatic NC (normally closed) valves are widely used in high density microfluidics systems. To improve actuation reliability, the actuation pressure needs to be reduced. In this work, we utilize 3D FEM (finite element method) modelling to get an insight into the valve actuation process numerically. Specifically, the progressive debonding process at the elastomer interface is simulated with CZM (cohesive zone model) method. To minimize the actuation pressure, the V-shape design has been investigated and compared with a normal straight design. The geometrical effects of valve shape has been elaborated, in terms of valve actuation pressure. Based on our simulated results, we formulate the main concerns for micro valve design and fabrication, which is significant for minimizing actuation pressures and ensuring reliable operation.
NASA Astrophysics Data System (ADS)
Meng, Fei; Shi, Peng; Karimi, Hamid Reza; Zhang, Hui
2016-02-01
The main objective of this paper is to investigate the sensitivity analysis and optimal design of a proportional solenoid valve (PSV) operated pressure reducing valve (PRV) for heavy-duty automatic transmission clutch actuators. The nonlinear electro-hydraulic valve model is developed based on fluid dynamics. In order to implement the sensitivity analysis and optimization for the PRV, the PSV model is validated by comparing the results with data obtained from a real test-bench. The sensitivity of the PSV pressure response with regard to the structural parameters is investigated by using Sobol's method. Finally, simulations and experimental investigations are performed on the optimized prototype and the results reveal that the dynamical characteristics of the valve have been improved in comparison with the original valve.
NASA Astrophysics Data System (ADS)
Dorier, J.-L.; Hilleret, N.
1998-11-01
Dust particle contamination is known to be responsible for reduced quality and yield in microelectronic processing. However it may also limit the operation of particle accelerators as a result of beam lifetime reduction or enhanced field emission in radio-frequency accelerating cavities. Intrinsic dust contamination from sources such as valves or ion pumps has not yet been studied due to the inability of commercial particle counters to be able to detect across large cross sections under ultrahigh vacuum (UHV) conditions. This motivated the development of the dust particle detector described here which is able to quantify, in situ, the level of contamination on a representative part of a vacuum vessel. This system operates under UHV conditions and measures flashes of scattered light from free falling dust particles as they cross a thin laser light sheet across a 100 mm diam vacuum vessel. A calibration using microspheres of known diameter has allowed estimation of the particle size from the scattered signal amplitude. Measurements of particulate contamination generated by shocks onto the vessel walls are presented and determination of the height of origin of dust particles from their transit time across the irradiation sheet is discussed. Measurements of dust particle release right to operation of an all-metal gate valve are also presented in the form of time resolved measurements of dust occurrence during the open/close cycles of the valve, as well as histograms of the particle size distribution. A partial self-cleaning effect is witnessed during the first 10 operation cycles following valve installation. The operation of an ion pump has also been investigated and revealed that, in our conditions, particles were released only at pump startup.
Shape-based diagnosis of the aortic valve
NASA Astrophysics Data System (ADS)
Ionasec, Razvan Ioan; Tsymbal, Alexey; Vitanovski, Dime; Georgescu, Bogdan; Zhou, S. Kevin; Navab, Nassir; Comaniciu, Dorin
2009-02-01
Disorders of the aortic valve represent a common cardiovascular disease and an important public-health problem worldwide. Pathological valves are currently determined from 2D images through elaborate qualitative evalu- ations and complex measurements, potentially inaccurate and tedious to acquire. This paper presents a novel diagnostic method, which identies diseased valves based on 3D geometrical models constructed from volumetric data. A parametric model, which includes relevant anatomic landmarks as well as the aortic root and lea ets, represents the morphology of the aortic valve. Recently developed robust segmentation methods are applied to estimate the patient specic model parameters from end-diastolic cardiac CT volumes. A discriminative distance function, learned from equivalence constraints in the product space of shape coordinates, determines the corresponding pathology class based on the shape information encoded by the model. Experiments on a heterogeneous set of 63 patients aected by various diseases demonstrated the performance of our method with 94% correctly classied valves.
NASA Astrophysics Data System (ADS)
Kamili Zahidi, M.; Razali Hanipah, M.
2017-10-01
A two-stroke poppet valve engine is developed to overcome the common problems in conventional two-stroke engine designs. However, replacing piston control port with poppet valve will resulted different flow behaviour. This paper presents the model and simulation result of three-dimensional (3D) port flow investigation of a two-stroke poppet valve engine. The objective of the investigation is to conduct a numerical investigation on port flow performance of two-stroke poppet valve engine and compare the results obtained from the experimental investigation. The model is to be used for the future numerical study of the engine. The volume flow rate results have been compared with the results obtained experimentally as presented in first part of this paper. The model has shown good agreement in terms of the flow rate at initial and final valve lifts but reduced by about 50% during half-lift region.
1980-04-01
problems might arise that would not occur in the absence of the system. Such problems include generation of static charges and pyrophoric iron ...gas isolating valves should take into account the temperature ofogas at the offtake. Cast iron is acceptable for temperatures below C20 0. Valves... sulfide , *Each U.S.-flag tankship that is certified to carry Grades A, B, C, D, and some E liquids. i1 2 which can ignite spontaneously or emit sparks when
The optimization of design parameters for surge relief valve for pipeline systems
NASA Astrophysics Data System (ADS)
Kim, Hyunjun; Hur, Jisung; Kim, Sanghyun
2017-06-01
Surge is an abnormal pressure which induced by rapid changes of flow rate in pipeline systems. In order to protect pipeline system from the surge pressure, various hydraulic devices have been developed. Surge-relief valve(SRV) is one of the widely applied devices to control surge due to its feasibility in application, efficiency and cost-effectiveness. SRV is designed to automatically open under abnormal pressure and discharge the flow and makes pressure of the system drop to the allowable level. The performance of the SRV is influenced by hydraulics. According to previous studies, there are several affecting factors which determine performance of the PRV such as design parameters (e.g. size of the valve), system parameters (e.g. number of the valves and location of the valve), and operation parameters (e.g. set point and operation time). Therefore, the systematic consideration for factors affecting performance of SRV is required for the proper installation of SRV in the system. In this study, methodology for finding optimum parameters of the SRV is explored through the integration of Genetic Algorithm(GA) into surge analysis.
NASA Astrophysics Data System (ADS)
Han, Yung-Min; Han, Chulhee; Kim, Wan Ho; Seong, Ho Yong; Choi, Seung-Bok
2016-09-01
This technical note presents control performances of a piezoactuator direct drive valve (PDDV) operated at high temperature environment. After briefly discussing operating principle and mechanical dimensions of the proposed PDDV, an appropriate size of the PDDV is manufactured. As a first step, the temperature effect on the valve performance is experimentally investigated by measuring the spool displacement at various temperatures. Subsequently, the PDDV is thermally insulated using aerogel and installed in a large-size heat chamber in which the pneumatic-hydraulic cylinders and sensors are equipped. A proportional-integral-derivative feedback controller is then designed and implemented to control the spool displacement of the valve system. In this work, the spool displacement is chosen as a control variable since it is directly related to the flow rate of the valve system. Three different sinusoidal displacements with different frequencies of 1, 10 and 50 Hz are used as reference spool displacement and tracking controls are undertaken up to 150 °C. It is shown that the proposed PDDV with the thermal insulation can provide favorable control responses without significant tracking errors at high temperatures.
A high risk critical mitral valve stenosis with emergency management at Apollo Hospitals Dhaka.
Zahangir, N M; Hoque, K Z; Khan, M H; Haque, M A; Haider, M Z
2013-10-01
Heart valve surgery in high-risk patients with severe jaundice, congestive hepatomegaly and renal impairment is associated with considerable morbidity and mortality. Without operation the consequences are invariably grave. A 35 years old gentleman with congestive cardiac failure was initially treated in coronary care unit (CCU). Mitral valve area was 0.5cm², pulmonary arterial systolic pressure (PASP) was 110mmHg, serum bilirubin was 20mg/dl, SGPT & SGOT were 1024iu/l and 1027iu/l respectively. Serum creatinine was 3.35mmol/l. Serum bilirubin gradually diminished to 3.1mg/dl after 12 days treatment in Coronary Care Unit but next day it increased to 3.6mg/dl. Mitral valve was replaced on an emergency basis. Echocardiogram on the 5th post operative day showed well functioning prosthetic mitral valve in situ. Serum bilirubin decreased to 2.2mg/dl, SGPT, SGOT and serum creatinine to 43iu/l, 40iu/l and 1.34mmol/l respectively. After 8 weeks of postoperative follow up his serum bilirubin decreased to 0.8mg/dl.
Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside
Saxon, John T; Allen, Keith B; Cohen, David J
2018-01-01
Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient–prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient–prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions. PMID:29593832
A patient-specific aortic valve model based on moving resistive immersed implicit surfaces.
Fedele, Marco; Faggiano, Elena; Dedè, Luca; Quarteroni, Alfio
2017-10-01
In this paper, we propose a full computational framework to simulate the hemodynamics in the aorta including the valve. Closed and open valve surfaces, as well as the lumen aorta, are reconstructed directly from medical images using new ad hoc algorithms, allowing a patient-specific simulation. The fluid dynamics problem that accounts from the movement of the valve is solved by a new 3D-0D fluid-structure interaction model in which the valve surface is implicitly represented through level set functions, yielding, in the Navier-Stokes equations, a resistive penalization term enforcing the blood to adhere to the valve leaflets. The dynamics of the valve between its closed and open position is modeled using a reduced geometric 0D model. At the discrete level, a finite element formulation is used and the SUPG stabilization is extended to include the resistive term in the Navier-Stokes equations. Then, after time discretization, the 3D fluid and 0D valve models are coupled through a staggered approach. This computational framework, applied to a patient-specific geometry and data, allows to simulate the movement of the valve, the sharp pressure jump occurring across the leaflets, and the blood flow pattern inside the aorta.
Massimo, C G; Presenti, L F; Favi, P P; Duranti, A; Poma, A G; Marranci, P; Modiano, C
1987-12-01
Twenty-four cases of acute type-A aortic dissection with aortic valvular insufficiency were treated in our institution by means of an emergency operation in which the aortic valve, ascending aorta, and aortic arch were resected and replaced with a valved conduit that had been lengthened with a tubular Dacron graft. The procedure included the use of deep hypothermia for cerebral protection, as well as extracorporeal circulation. Aortic resection was performed from the aortic valve to the origin of the descending thoracic aorta; the aortic graft was anastomosed proximally to the valve annulus and distally to the descending aorta. The carotid orifices were connected to the side of the graft in a single tissue button. The coronary arteries were then reconnected by means of double venous bypass grafts to the innominate artery, to allow for inclusion of the graft. Within 1 month after operation, four patients died of the consequences of dissection. Six months postoperatively, one patient succumbed to an infarction. Six months to 5 years after operation, the remaining 19 patients are still alive. On the basis of this experience, we believe that acute type-A aortic dissection with aortic valvular insufficiency should be treated during the first hours after the onset of symptoms. The above-described procedure proved effective in the control of bleeding, which is the major risk in emergency operations of this type.
Pressure Regulators as Valves for Saving Compressed Air and their Influence on System Dynamics
NASA Astrophysics Data System (ADS)
Dvořák, Lukáš; Fojtášek, Kamil
2015-05-01
Pressure regulators in the field of pneumatic mechanisms can be used as valves for saving compressed air. For example it can be used to reduce the pressure when the piston rod is retracting unloaded and thus it is possible to save some energy. However the problem is that saving valve can significantly affect the dynamics of the pneumatic system. The lower pressure in the piston rod chamber causes extension of time for retraction of the piston rod. This article compare the air consumption experimentally determined and calculated, measured curves of pressure in cylinder chambers and piston speed when saving valve is set up differently.
Optical memory development. Volume 3: The membrane light value page composer
NASA Technical Reports Server (NTRS)
Cosentino, L. S.; Nagle, E. M.; Stewart, W. C.
1972-01-01
The feasibility of producing a page composer for optical memory systems using thin, deformable, membrane-mirror elements as light valves was investigated. The electromechanical and optical performances of such elements were determined both analytically and experimentally. It was found that fast switching (approximately 10 microseconds), high-contrast (10 or greater), fatigue-free operation over missions of cycles, and efficient utilization of input light could be obtained with membrane light valves. Several arrays of 64 elements were made on substrates with feedthroughs, allowing access to individual elements from the backside of the substrate. Single light valves on such arrays were successfully operated with the transistors designed and produced for selection and storage at each bit location. This simulated the operation of a prototype page composer with semiconductor chips beam-lead bonded to the back of the substrate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scott, D.D.; Jones, H.E.
1994-05-06
Prosthetic heart valves have increased the life span of many patients with life threatening heart conditions. These valves have proven extremely reliable adding years to what would have been weeks to a patient`s life. Prosthetic valves, like the heart however, can suffer from this constant work load. A small number of valves have experienced structural fractures of the outlet strut due to fatigue. To study this problem a non-intrusive method to classify valves has been developed. By extracting from an acoustic signal the opening sounds which directly contain information from the outlet strut and then developing features which are suppliedmore » to an adaptive classification scheme (neural network) the condition of the valve can be determined. The opening sound extraction process has proved to be a classification problem itself. Due to the uniqueness of each heart and the occasional irregularity of the acoustic pattern it is often questionable as to the integrity of a given signal (beat), especially one occurring during an irregular beat pattern. A common cause of these irregular patterns is a condition known as atrial fibrillation, a prevalent arrhythmia among patients with prosthetic hear valves. Atrial fibrillation is suspected when the ECG shows no obvious P-waves. The atria do not contract and relax correctly to help contribute to ventricular filling during a normal cardiac cycle. Sometimes this leads to irregular patterns in the acoustic data. This study compares normal beat patterns to irregular patterns of the same heart. By analyzing the spectral content of the beats it can be determined whether or not these irregular patterns can contribute to the classification of a heart valve or if they should be avoided. The results have shown that the opening sounds which occur during irregular beat patterns contain the same spectral information as the opening which occur during a normal beat pattern of the same heart and these beats can be used for classification.« less
Chouvenc, P; Vessot, S; Andrieu, J; Vacus, P
2005-01-01
The principal aim of this study is to extend to a pilot freeze-dryer equipped with a non-instantaneous isolation valve the previously presented pressure rise analysis (PRA) model for monitoring the product temperature and the resistance to mass transfer of the dried layer during primary drying. This method, derived from the original MTM method previously published, consists of interrupting rapidly (a few seconds) the water vapour flow from the sublimation chamber to the condenser and analysing the resulting dynamics of the total chamber pressure increase. The valve effect on the pressure rise profile observed during the isolation valve closing period was corrected by introducing in the initial PRA model a valve characteristic function factor which turned out to be independent of the operating conditions. This new extended PRA model was validated by implementing successively the two types of valves and by analysing the pressure rise kinetics data with the corresponding PRA models in the same operating conditions. The coherence and consistency shown on the identified parameter values (sublimation front temperature, dried layer mass transfer resistance) allowed validation of this extended PRA model with a non-instantaneous isolation valve. These results confirm that the PRA method, with or without an instantaneous isolation valve, is appropriate for on-line monitoring of product characteristics during freeze-drying. The advantages of PRA are that the method is rapid, non-invasive, and global. Consequently, PRA might become a powerful and promising tool not only for the control of pilot freeze-dryers but also for industrial freeze-dryers equipped with external condensers.
Murphy, I G; Collins, J; Powell, A; Markl, M; McCarthy, P; Malaisrie, S C; Carr, J C; Barker, A J
2017-08-01
Bicuspid aortic valve (BAV) disease is heterogeneous and related to valve dysfunction and aortopathy. Appropriate follow up and surveillance of patients with BAV may depend on correct phenotypic categorization. There are multiple classification schemes, however a need exists to comprehensively capture commissure fusion, leaflet asymmetry, and valve orifice orientation. Our aim was to develop a BAV classification scheme for use at MRI to ascertain the frequency of different phenotypes and the consistency of BAV classification. The BAV classification scheme builds on the Sievers surgical BAV classification, adding valve orifice orientation, partial leaflet fusion and leaflet asymmetry. A single observer successfully applied this classification to 386 of 398 Cardiac MRI studies. Repeatability of categorization was ascertained with intraobserver and interobserver kappa scores. Sensitivity and specificity of MRI findings was determined from operative reports, where available. Fusion of the right and left leaflets accounted for over half of all cases. Partial leaflet fusion was seen in 46% of patients. Good interobserver agreement was seen for orientation of the valve opening (κ = 0.90), type (κ = 0.72) and presence of partial fusion (κ = 0.83, p < 0.0001). Retrospective review of operative notes showed sensitivity and specificity for orientation (90, 93%) and for Sievers type (73, 87%). The proposed BAV classification schema was assessed by MRI for its reliability to classify valve morphology in addition to illustrating the wide heterogeneity of leaflet size, orifice orientation, and commissural fusion. The classification may be helpful in further understanding the relationship between valve morphology, flow derangement and aortopathy.
System for remotely servicing a top loading captive ball valve
Berry, Stephen M.; Porter, Matthew L.
1996-01-01
An attachment for facilitating servicing of a valve, the valve including: an assembly composed of a valve seat defining a flow path, a flow control member movable relative to the valve seat for blocking or unblocking the valve seat, and a control device including a stem coupled to the flow control member and operable for moving the flow control member relative to the valve seat; a housing for receiving the assembly, the housing having an opening via which the assembly can be removed from, and installed in, the housing, and the housing having a plurality of threaded studs which surround the opening and project away from the housing; a valve housing cover for closing and sealing the opening in the housing, the cover having a first bore for passage of the stem of the control device when the assembly is installed in the housing and a plurality of second bores each located for passage of a respective stud when the cover closes the opening in the housing. A plurality of threaded nuts are engageable with the studs for securing the cover to the housing when the cover closes the opening in the housing, wherein the attachment comprises: a plurality of nut guide devices removable from the housing and each operatively associated with a respective stud for retaining a respective nut and guiding the respective nut into alignment with the respective stud to enable the respective nut to be rotated into engagement with the respective stud; and aligning the nut guide devices with the studs.
Holinski, Sebastian; Zhigalov, Konstantin; Zielinski, Christina Barbara; Grubitzsch, Herko
2017-01-01
Purpose: Hemodynamic performance of aortic valve bioprostheses is essential for reliable function and durability. So far, the supra-annularly implanted stentless Sorin Freedom Solo (SFS) demonstrated unsurpassed hemodynamic properties. As contemporary stented and externally mounted pericardial bioprostheses, like the Labcor Dokimos Plus (LDP), also improve hemodynamic performance, these types of valves were compared in this study. Methods: A total of 218 patients, who underwent aortic valve replacement with the LDP or the SFS, were matched retrospectively 1:1 on variables affecting hemodynamic measurements: implanted valve size, age, sex, and body surface area (BSA). With matching tolerance for valve size and gender of 0%, for age and BSA of 5%, 57 patient-pairs were yielded. Operative data, clinical, and hemodynamic outcome were analyzed. Results: Except for slightly higher left ventricular function and lower procedural times in the SFS group, preoperative, operative, and postoperative characteristics of patient-pairs did not differ significantly. Mean pressure gradients, effective orifice areas (EOAs), and indexed EOAs were comparable. Corresponding to valve sizes of 21, 23, 25, and 27 mm, the indexed EOAs of the LDP and SFS prostheses were 1.08 ± 0.33, 0.92 ± 0.19, 0.93 ± 0.24, 0.99 ± 0.13 cm2/m2 and 0.81 ± 0.13, 0.92 ± 0.28, 0.95 ± 0.20, 1.04 ± 0.27 cm2/m2, respectively. Conclusion: Contemporary stented and stentless pericardial bioprostheses showed excellent hemodynamic properties without significant differences in EOAs and indexed EOAs. PMID:28890465
Neural-network-based state of health diagnostics for an automated radioxenon sampler/analyzer
NASA Astrophysics Data System (ADS)
Keller, Paul E.; Kangas, Lars J.; Hayes, James C.; Schrom, Brian T.; Suarez, Reynold; Hubbard, Charles W.; Heimbigner, Tom R.; McIntyre, Justin I.
2009-05-01
Artificial neural networks (ANNs) are used to determine the state-of-health (SOH) of the Automated Radioxenon Analyzer/Sampler (ARSA). ARSA is a gas collection and analysis system used for non-proliferation monitoring in detecting radioxenon released during nuclear tests. SOH diagnostics are important for automated, unmanned sensing systems so that remote detection and identification of problems can be made without onsite staff. Both recurrent and feed-forward ANNs are presented. The recurrent ANN is trained to predict sensor values based on current valve states, which control air flow, so that with only valve states the normal SOH sensor values can be predicted. Deviation between modeled value and actual is an indication of a potential problem. The feed-forward ANN acts as a nonlinear version of principal components analysis (PCA) and is trained to replicate the normal SOH sensor values. Because of ARSA's complexity, this nonlinear PCA is better able to capture the relationships among the sensors than standard linear PCA and is applicable to both sensor validation and recognizing off-normal operating conditions. Both models provide valuable information to detect impending malfunctions before they occur to avoid unscheduled shutdown. Finally, the ability of ANN methods to predict the system state is presented.
New Hardware for Tethered Balloons,
1980-01-01
package contained a differential- pressure switch , and a command receiver. Long wires extended up to the gas valves to actuate them, and a long tube was...similar in appear- ance to the former valve, but does contain batteries, an aneroid- operated switch, and a differential- pressure switch . Design is such...that either the aneroid-operated switch or the differential- pressure switch can be easily removed for checking Or setting in the laboratory. Likewise the
Code of Federal Regulations, 2010 CFR
2010-10-01
... operator at the cargo pump controls. (c) Each pipe and valve in the pumping system that has an open end... with the procedures in § 50.25-10 of this chapter. (e) A non-return valve must be in the pump discharge...
Code of Federal Regulations, 2011 CFR
2011-10-01
... operator at the cargo pump controls. (c) Each pipe and valve in the pumping system that has an open end... with the procedures in § 50.25-10 of this chapter. (e) A non-return valve must be in the pump discharge...
Code of Federal Regulations, 2013 CFR
2013-10-01
... operator at the cargo pump controls. (c) Each pipe and valve in the pumping system that has an open end... with the procedures in § 50.25-10 of this chapter. (e) A non-return valve must be in the pump discharge...
Code of Federal Regulations, 2014 CFR
2014-10-01
... operator at the cargo pump controls. (c) Each pipe and valve in the pumping system that has an open end... with the procedures in § 50.25-10 of this chapter. (e) A non-return valve must be in the pump discharge...
Code of Federal Regulations, 2012 CFR
2012-10-01
... operator at the cargo pump controls. (c) Each pipe and valve in the pumping system that has an open end... with the procedures in § 50.25-10 of this chapter. (e) A non-return valve must be in the pump discharge...
Excess flow valve benefit/cost analysis.
DOT National Transportation Integrated Search
1994-12-31
The Office of Pipeline Safety (OPS) is adopting regulations requiring the installation of Excess Flow Valves (EFVs) on all new or renewed single-family residential gas services that operate at pressures that are always 10 psig (pounds per square inch...
Inlet Flow Valve Engine Analyses
NASA Technical Reports Server (NTRS)
Champagne, G. A.
2004-01-01
Pratt&Whitney, under Task Order 13 of the NASA Large Engine Technology (LET) Contract, conducted a study to determine the operating characteristics, performance and weights of Inlet Flow Valve (IFV) propulsion concepts for a Mach 2.4 High Speed Civil Transport (HSCT).
Guteta, Senbeta; Yadeta, Dejuma; Azazh, Aklilu; Mekonnen, Dufera
2016-04-01
Valvular heart disease has been a significant cause of heart disease worldwide. In Ethiopia, it particularly affects young individuals and constitutes the major cause of cardiovascular disease. Factors associated with choice of treatment for advanced valvular heart disease are variable. The objective of this study is to review surgery done for Ethiopian patients with valvular heart disease. We analyzed data on patients who had valve surgery and follow-up at the Tikur Anbessa Specialized Hospital cardiology unit. We collected data on sociodemographic characteristics, the pre-operative status of effected valves and co-morbidities, and assessed their associations with patient management options. A total of 157 valve surgeries were done from 1983 to 2013. Mean age at time of surgery was 26.7 years and females constituted 66% of the cases. Patients with rheumatic heart disease were younger, more likely to be female and have atrial fibrillation, but less likely to have impaired left ventricular systolic function when compared to patients with non-rheumatic heart disease. More than 75% of the surgical procedures done were mechanical valve replacement. Mechanical valves, compared with bioprosthetic valves, were more likely to be used in patients with rheumatic heart disease. The median age of those receiving mechanical valves, 24 (IQR 22-28) years, was lower than those receiving bioprosthetic valves, 31.5 (IQR 29.9-37.9) years. Mechanical valve replacement was significantly higher in those under the age of 20 years (Adjusted Odds Ratio 41.0, 95% CI: 3.0-557.2) and in those between 20 and 29 years of age (Adjusted Odds Ratio 14.3, 95% CI: 2.3-88.6). Valve surgery for valvular heart diseases has been more common performed for young and female patients. A great majority of the replacements done have been with mechanical valves. As many of the patients have been younger and female, the choice of valve surgery and the need for anticoagulation impacts subsequent management of rheumatic heart disease and associated morbidities, lifestyle plans and pregnancy.
Fluid-dynamic design optimization of hydraulic proportional directional valves
NASA Astrophysics Data System (ADS)
Amirante, Riccardo; Catalano, Luciano Andrea; Poloni, Carlo; Tamburrano, Paolo
2014-10-01
This article proposes an effective methodology for the fluid-dynamic design optimization of the sliding spool of a hydraulic proportional directional valve: the goal is the minimization of the flow force at a prescribed flow rate, so as to reduce the required opening force while keeping the operation features unchanged. A full three-dimensional model of the flow field within the valve is employed to accurately predict the flow force acting on the spool. A theoretical analysis, based on both the axial momentum equation and flow simulations, is conducted to define the design parameters, which need to be properly selected in order to reduce the flow force without significantly affecting the flow rate. A genetic algorithm, coupled with a computational fluid dynamics flow solver, is employed to minimize the flow force acting on the valve spool at the maximum opening. A comparison with a typical single-objective optimization algorithm is performed to evaluate performance and effectiveness of the employed genetic algorithm. The optimized spool develops a maximum flow force which is smaller than that produced by the commercially available valve, mainly due to some major modifications occurring in the discharge section. Reducing the flow force and thus the electromagnetic force exerted by the solenoid actuators allows the operational range of direct (single-stage) driven valves to be enlarged.
Valve replacement in children: a challenge for a whole life.
Henaine, Roland; Roubertie, François; Vergnat, Mathieu; Ninet, Jean
2012-10-01
Valvular pathology in infants and children poses numerous challenges to the paediatric cardiac surgeon. Without question, valvular repair is the goal of intervention because restoration of valvular anatomy and physiology using native tissue allows for growth and a potentially better long-term outcome. When reconstruction fails or is not feasible, valve replacement becomes inevitable. Which valve for which position is controversial. Homograft and bioprosthetic valves achieve superior haemodynamic results initially but at the cost of accelerated degeneration. Small patient size and the risk of thromboembolism limit the usefulness of mechanical valves, and somatic outgrowth is an universal problem with all available prostheses. The goal of this article is to address valve replacement options for all four valve positions within the paediatric population. We review current literature and our practice to support our preferences. To summarize, a multitude of opinions and surgical experiences exist. Today, the valve choices that seem without controversy are bioprosthetic replacement of the tricuspid valve and Ross or Ross-Konno procedures when necessary for the aortic valve. On the other hand, bioprostheses may be implanted when annular pulmonary diameter is adequate; if not or in case of right ventricular outflow tract discontinuity, it is better to use a pulmonary homograft with the Ross procedure. Otherwise, a valved conduit. Mitral valve replacement remains the most problematic; the mechanical prosthesis must be placed in the annular position, avoiding oversizing. Future advances with tissue-engineered heart valves for all positions and new anticoagulants may change the landscape for valve replacement in the paediatric population. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
NASA Technical Reports Server (NTRS)
Romanowski, William E. (Inventor); Suljak, George T. (Inventor)
1989-01-01
A fuel cell power system for use in a weightless environment, such as in space, includes a device for removing water from a water-hydrogen mixture condensed from the exhaust from the fuel cell power section of the system. Water is removed from the mixture in a centrifugal separator, and is fed into a holding, pressure operated water discharge valve via a Pitot tube. Entrained nondissolved hydrogen is removed from the Pitot tube by a bleed orifice in the Pitot tube before the water reaches the water discharge valve. Water discharged from the valve thus has a substantially reduced hydrogen content.
Foot pedal operated fluid type exercising device
NASA Technical Reports Server (NTRS)
Crum, G. W.; Sauter, R. J. (Inventor)
1973-01-01
A foot pedal operated exercising device is reported that contains a dynamometer formed of a pair of cylinders each containing a piston. The pistons are linked to each other. The upper portions of the two cylinders are joined together by a common opening to provide a common fluid reservoir and each piston is provided with a one way check valve to maintain an adequate supply of working fluid. Fluid from the driven cylinder is transmitted to the other cylinder through separate constant force spring biased valves each valve takes the predominant portion of the pressure drop thereby providing a constant force hydraulic dynamometer. A device is provided to determine the amount of movement of piston travel.
Gas Fuelling System for SST-1Tokamak
NASA Astrophysics Data System (ADS)
Dhanani, Kalpesh; Raval, D. C.; Khan, Ziauddin; Semwal, Pratibha; George, Siju; Paravastu, Yuvakiran; Thankey, Prashant; Khan, M. S.; Pradhan, Subrata
2017-04-01
SST-1 Tokamak, the first Indian Steady-state Superconducting experimental device is at present under operation in the Institute for Plasma Research. For plasma break down & initiation, piezoelectric valve based gas feed system is implemented as a primary requirement due to its precise control, easy handling, low construction and maintenance cost and its flexibility in the selection of the working gas. Hydrogen gas feeding with piezoelectric valve is used in the SST-1 plasma experiments. The piezoelectric valves used in SST-1 are remotely driven by a PXI based platform and are calibrated before each SST-1 plasma operation with precise control. This paper will present the technical development and the results of the gas fuelling system of SST-1.
Accuracy assessment of fluoroscopy-transesophageal echocardiography registration
NASA Astrophysics Data System (ADS)
Lang, Pencilla; Seslija, Petar; Bainbridge, Daniel; Guiraudon, Gerard M.; Jones, Doug L.; Chu, Michael W.; Holdsworth, David W.; Peters, Terry M.
2011-03-01
This study assesses the accuracy of a new transesophageal (TEE) ultrasound (US) fluoroscopy registration technique designed to guide percutaneous aortic valve replacement. In this minimally invasive procedure, a valve is inserted into the aortic annulus via a catheter. Navigation and positioning of the valve is guided primarily by intra-operative fluoroscopy. Poor anatomical visualization of the aortic root region can result in incorrect positioning, leading to heart valve embolization, obstruction of the coronary ostia and acute kidney injury. The use of TEE US images to augment intra-operative fluoroscopy provides significant improvements to image-guidance. Registration is achieved using an image-based TEE probe tracking technique and US calibration. TEE probe tracking is accomplished using a single-perspective pose estimation algorithm. Pose estimation from a single image allows registration to be achieved using only images collected in standard OR workflow. Accuracy of this registration technique is assessed using three models: a point target phantom, a cadaveric porcine heart with implanted fiducials, and in-vivo porcine images. Results demonstrate that registration can be achieved with an RMS error of less than 1.5mm, which is within the clinical accuracy requirements of 5mm. US-fluoroscopy registration based on single-perspective pose estimation demonstrates promise as a method for providing guidance to percutaneous aortic valve replacement procedures. Future work will focus on real-time implementation and a visualization system that can be used in the operating room.
Absence of posterior tricuspid valve leaflet and valve reconstruction
Komoda, Takeshi; Stamm, Christof; Fleck, Eckart; Hetzer, Roland
2012-01-01
We report a rare case of the absence of a posterior tricuspid valve leaflet. A male patient, aged 46, suffering from severe tricuspid valve regurgitation (TR) of unknown aetiology and atrial septal aneurysm was referred to our hospital for surgery. On surgical inspection, the posterior tricuspid valve leaflet and its subvalvular apparatus were completely absent and only the valve annulus was seen in the corresponding position. The anterior and septal leaflets were normal. We successfully reconstructed the tricuspid valve as follows: the head of an anterior papillary muscle was approximated to the ventricular septum (Sebening stitch). After the approximation of the centre of the tricuspid annulus of the anterior leaflet to the tricuspid annulus on the opposite side, a sizer of 29 mm in diameter was easily passed through the anterior orifice. The posterior orifice was closed with running sutures (posterior annulorrhaphy after Hetzer). Before these procedures, we attempted to reconstruct the tricuspid valve with a posterior annulorrhaphy alone; however, valve competence was insufficient. A Sebening stitch was necessary to improve the valve competence. Echocardiography showed TR grade 1 at the patient's discharge from hospital and TR grade 1 to 2 at the follow-up, 10 months after the operation. PMID:22419794
Automatic Mesh Generation of Hybrid Mesh on Valves in Multiple Positions in Feedline Systems
NASA Technical Reports Server (NTRS)
Ross, Douglass H.; Ito, Yasushi; Dorothy, Fredric W.; Shih, Alan M.; Peugeot, John
2010-01-01
Fluid flow simulations through a valve often require evaluation of the valve in multiple opening positions. A mesh has to be generated for the valve for each position and compounding. The problem is the fact that the valve is typically part of a larger feedline system. In this paper, we propose to develop a system to create meshes for feedline systems with parametrically controlled valve openings. Herein we outline two approaches to generate the meshes for a valve in a feedline system at multiple positions. There are two issues that must be addressed. The first is the creation of the mesh on the valve for multiple positions. The second is the generation of the mesh for the total feedline system including the valve. For generation of the mesh on the valve, we will describe the use of topology matching and mesh generation parameter transfer. For generation of the total feedline system, we will describe two solutions that we have implemented. In both cases the valve is treated as a component in the feedline system. In the first method the geometry of the valve in the feedline system is replaced with a valve at a different opening position. Geometry is created to connect the valve to the feedline system. Then topology for the valve is created and the portion of the topology for the valve is topology matched to the standard valve in a different position. The mesh generation parameters are transferred and then the volume mesh for the whole feedline system is generated. The second method enables the user to generate the volume mesh on the valve in multiple open positions external to the feedline system, to insert it into the volume mesh of the feedline system, and to reduce the amount of computer time required for mesh generation because only two small volume meshes connecting the valve to the feedline mesh need to be updated.
Recycle dynamics during centrifugal compressor ESD, start-up and surge control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Botros, K.K.; Jones, B.J.; Richards, D.J.
1996-12-31
Recycle systems are important components in the operation of centrifugal compressor stations. They are essential during a start-up operation, for surge protection and for emergency shutdown (ESD). These operations are inherently dynamic where interactions between equipment, control and gas flow occur in a complex manner with the associated risk of compressor surge. Of particular importance are the effects or recycle system capacity, the recycle valve characteristics, check valve dynamic behavior, piping geometry and capacitance around the compressor unit, and the performance characteristics of the centrifugal compressor itself. This paper presents numerical results of the effects of some of these parametersmore » on surge control, ESD and unit startup. These parameters are: (1) The effects of damping the surge control flow signal in an attempt to suppress the signal noise, on the integrity of the surge control system; (2) The effects of recycle valve characteristics, stroke time and valve capacity on ESD; (3) The effects of recycle line size on ESD; and (4) The effects of the recycle valve closing time (or rate) on the startup operation, with the intent of shortening this time to minimum for environmental reasons. Results were obtained from the solution of the pertinent dynamic equations describing the gas and equipment dynamics which has been verified against field and laboratory measurements. The samples presented in this paper were applied to a 24 MW natural gas compressor station on the NOVA Gas Transmission system, and to a scale-down laboratory model. Influence of other parameters from this investigation were published elsewhere and are cited in the reference section.« less
Reversible thermo-pneumatic valves on centrifugal microfluidic platforms.
Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Kazemzadeh, Amin; Rothan, Hussin A; Yusof, Rohana; Madou, Marc
2015-08-21
Centrifugal microfluidic systems utilize a conventional spindle motor to automate parallel biochemical assays on a single microfluidic disk. The integration of complex, sequential microfluidic procedures on these platforms relies on robust valving techniques that allow for the precise control and manipulation of fluid flow. The ability of valves to consistently return to their former conditions after each actuation plays a significant role in the real-time manipulation of fluidic operations. In this paper, we introduce an active valving technique that operates based on the deflection of a latex film with the potential for real-time flow manipulation in a wide range of operational spinning speeds. The reversible thermo-pneumatic valve (RTPV) seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. The RTPV is a gas-impermeable valve composed of an air chamber enclosed by a latex membrane and a specially designed liquid transition chamber that enables the efficient usage of the applied thermal energy. Inputting thermo-pneumatic (TP) energy into the air chamber deflects the membrane into the liquid transition chamber against an inlet, sealing it and thus preventing fluid flow. From this point, a centrifugal pressure higher than the induced TP pressure in the air chamber reopens the fluid pathway. The behaviour of this newly introduced reversible valving system on a microfluidic disk is studied experimentally and theoretically over a range of rotational frequencies from 700 RPM to 2500 RPM. Furthermore, adding a physical component (e.g., a hemispherical rubber element) to induce initial flow resistance shifts the operational range of rotational frequencies of the RTPV to more than 6000 RPM. An analytical solution for the cooling of a heated RTPV on a spinning disk is also presented, which highlights the need for the future development of time-programmable RTPVs. Moreover, the reversibility and gas impermeability of the RTPV in the microfluidic networks are validated on a microfluidic disk designed for performing liquid circulation. Finally, an array of RTPVs is integrated into a microfluidic cartridge to enable sequential aliquoting for the conversion of dengue virus RNA to cDNA and the preparation of PCR reaction mixtures.
Bozkurt, Engin; Keleş, Telat; Durmaz, Tahir; Akçay, Murat; Ayhan, Hüseyin; Bayram, Nihal Akar; Aslan, Abdullah Nabi; Baştuğ, Serdal; Bilen, Emine
2014-01-01
Introduction Transcatheter aortic valve implantation is a promising alternative to high risk surgical aortic valve replacement. The procedure is mainly indicated in patients with severe symptomatic aortic stenosis who cannot undergo surgery or who are at very high surgical risk. Aim Description early results of our single-center experience with balloon expandable aortic valve implantation. Material and methods Between July 2011 and August 2012, we screened in total 75 consecutive patients with severe aortic stenosis and high risk for surgery. Twenty-one of them were found ineligible for transcatheter aortic valve implantation (TAVI) because of various reasons, and finally we treated a total of 54 patients with symptomatic severe aortic stenosis (AS) who could not be treated by open heart surgery (inoperable) because of high-risk criteria. The average age of the patients was 77.4 ±7.1; 27.8% were male and 72.2% were female. The number of patients in NYHA class II was 7 while the number of patients in class III and class IV was 47. Results The average mortality score of patients according to the STS scoring system was 8.5%. Pre-implantation mean and maximal aortic valve gradients were measured as 53.2 ±14.1 mm Hg and 85.5 ±18.9 mm Hg, respectively. Post-implantation mean and maximal aortic valve gradients were 9.0 ±3.0 and 18.2 ±5.6, respectively (p < 0.0001). The left ventricular ejection fraction was calculated as 54.7 ±14.4% before the operation and 58.0 ±11.1% after the operation (p < 0.0001). The duration of discharge after the operation was 5.29 days, and a statistically significant correlation between the duration of discharge after the operation and STS was found (r = 0385, p = 0.004). Conclusions We consider that with decreasing cost and increasing treatment experience, TAVI will be used more frequently in broader indications. Our experience with TAVI using the Edwards-Sapien XT (Edwards Lifesciences, Irvine, CA) devices suggests that this is an effective and relatively safe procedure for the treatment of severe aortic stenosis in suitable patients. PMID:25061453
Gil-Carrasco, F; Jiménez-Román, J; Turati-Acosta, M; Bello-López Portillo, H; Isida-Llerandi, C G
2016-09-01
To prospectively evaluate the safety and efficacy of the Ahmed glaucoma valve model M4 (High density porous polyethylene plate; Medpor) compared with the model S2 (polypropylene plate). Mexican patients with neovascular glaucoma were randomly included for each group (M4 and S2). They were operated on using conventional techniques and creating a sub-episcleral tunnel to place the valve tube in the anterior chamber. After one year of follow-up, the results were evaluated with respect to a post-operative reduction in pressure, changes in visual acuity, the need for drugs, and complications, as well as the demographic characteristics of each group. Each operation using the M4 valve was performed by a single surgeon (FGC). Those operated on using the S2 model had their surgery performed by the staff surgeons at the Glaucoma Department of the Mexican Association to Prevent Blindness (APEC). Each group (M4 and S2) contained 21 eyes of 21 Mexican patients with a diagnosis of neovascular glaucoma, leading to a total of 42 patients undergoing surgery. The mean preoperative intraocular pressure (IOP) was 43.5 (±11.8), and 42.24 (±12.84) mmHg for the M4 and S2 groups, respectively. After one year of follow-up, the IOP reported was 18.9 (±9.7) mmHg for the final 18 patients in the M4 group, and 16.38 (±9.76) mmHg for the 21 patients in the S2 group. The design of a drainage valve device such as that of Ahmed has characteristics such as moderate control of IOP, thanks to the valve component in the immediate post-operative period, which makes them safer than other non-valve devices. This avoids an excess of flat chambers and the presence of low IOPs, which can lead to bleeding in the early post-operative period due to the weak desmosomal junctions of the newly formed vessels, with the advantage of maintaining suitable control of IOP from the first day after surgery. Further studies with longer follow-up with a larger number of patients are needed to evaluate the effectiveness of this porous coating in the control of neovascular glaucoma. Copyright © 2016 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Chemical Safety Alert: Shaft Blow-Out Hazard of Check and Butterfly Valves
Certain types of check and butterfly valves can undergo shaft-disk separation and fail catastrophically, even when operated within their design limits of pressure and temperature, causing toxic/flammable gas releases, fires, and vapor cloud explosions.
TTK Chitra tilting disc heart valve model TC2: An assessment of fatigue life and durability.
Subhash, N N; Rajeev, Adathala; Sujesh, Sreedharan; Muraleedharan, C V
2017-08-01
Average age group of heart valve replacement in India and most of the Third World countries is below 30 years. Hence, the valve for such patients need to be designed to have a service life of 50 years or more which corresponds to 2000 million cycles of operation. The purpose of this study was to assess the structural performance of the TTK Chitra tilting disc heart valve model TC2 and thereby address its durability. The TC2 model tilting disc heart valves were assessed to evaluate the risks connected with potential structural failure modes. To be more specific, the studies covered the finite element analysis-based fatigue life prediction and accelerated durability testing of the tilting disc heart valves for nine different valve sizes. First, finite element analysis-based fatigue life prediction showed that all nine valve sizes were in the infinite life region. Second, accelerated durability test showed that all nine valve sizes remained functional for 400 million cycles under experimental conditions. The study ensures the continued function of TC2 model tilting disc heart valves over duration in excess of 50 years. The results imply that the TC2 model valve designs are structurally safe, reliable and durable.
Lee, Jung Hee; Kim, Tae Ho; Kim, Wook Sung
2015-04-01
Severe and permanent tricuspid regurgitation induced by pacemaker leads is rarely reported in the literature. The mechanism of pacemaker-induced tricuspid regurgitation has been identified, but its management has not been well established. Furthermore, debate still exists regarding the proper surgical approach. We present the case of a patient with severe tricuspid regurgitation induced by a pacemaker lead, accompanied by triple valve disease. The patient underwent double valve replacement and tricuspid valve repair without removal of the pre-existing pacemaker lead. The operation was successful and the surgical procedure is discussed in detail.