2014-01-01
Objective To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Method Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Results Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. Conclusions This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses. PMID:23965298
Youngstrom, Eric A
2014-03-01
To offer a practical demonstration of receiver operating characteristic (ROC) analyses, diagnostic efficiency statistics, and their application to clinical decision making using a popular parent checklist to assess for potential mood disorder. Secondary analyses of data from 589 families seeking outpatient mental health services, completing the Child Behavior Checklist and semi-structured diagnostic interviews. Internalizing Problems raw scores discriminated mood disorders significantly better than did age- and gender-normed T scores, or an Affective Problems score. Internalizing scores <8 had a diagnostic likelihood ratio <0.3, and scores >30 had a diagnostic likelihood ratio of 7.4. This study illustrates a series of steps in defining a clinical problem, operationalizing it, selecting a valid study design, and using ROC analyses to generate statistics that support clinical decisions. The ROC framework offers important advantages for clinical interpretation. Appendices include sample scripts using SPSS and R to check assumptions and conduct ROC analyses.
Madi, Haifa A; Dinah, Christiana; Rees, Jon; Steel, David H W
2015-01-01
Analysis of pre-operative spectral domain optical coherence tomography (SD-OCT) characteristics of full-thickness macular holes (FTMH) and effect on optimum management. We retrospectively reviewed SD-OCT characteristics of a consecutive cohort of patients waitlisted for FTMH surgery and categorized them by current evidence-based treatments. Out of the 106 holes analysed, 36 were small, 40 medium and 30 large. Initially, 33 holes had vitreomacular adhesion (VMA). 41 holes were analysed for change in characteristics with a median duration of 8 weeks between the scans. The number of small or medium holes decreased from 20 to 6 and that of large holes doubled. The number of holes with VMA halved. Smaller hole size (p = 0.014) and being phakic (p = 0.048) were associated with a larger increase in size. The strongest predictor of hole progression into a different surgical management category was the presence of VMA. FTMH characteristics can change significantly pre-operatively and affect optimal treatment choice.
Self-excited oscillation and monostable operation of a bistable light emitting diode (BILED)
NASA Astrophysics Data System (ADS)
Okumura, K.; Ogawa, Y.; Ito, H.; Inaba, H.
1983-07-01
A new simple opto-electronic bistable device has been obtained by combining a light emitting diode (LED) and a photodetector (PD) with electronic feedback using a broad bandpass filter. This has interesting dynamic characteristics which are expected to have such various applications as optical oscillators, optical pulse generators and optical pulsewidth modulators. The dynamic characteristics are represented by second-order nonlinear differential equations. In the analyses of these nonlinear systems, instead of numerical analyses with a computer, an approximate analytical method devised for this purpose has been used. This method has been used for investigating the characteristics of the proposed device quantitatively. These include the frequency of oscillations, pulsewidths and hysteresis. The results of the analyses agree approximately with experimentally observed values, thus the dynamic characteristics of the proposed device can be explained.
An Efficient Method for Classifying Perfectionists
ERIC Educational Resources Information Center
Rice, Kenneth G.; Ashby, Jeffrey S.
2007-01-01
Multiple samples of university students (N = 1,537) completed the Almost Perfect Scale-Revised (APS-R; R. B. Slaney, M. Mobley, J. Trippi, J. Ashby, & D. G. Johnson, 1996). Cluster analyses, cross-validated discriminant function analyses, and receiver operating characteristic curves for sensitivity and specificity of APS-R scores were used to…
Fuel cell power plant economic and operational considerations
NASA Technical Reports Server (NTRS)
Lance, J. R.
1984-01-01
Fuel cell power plants intended for electric utility and cogeneration applications are now in the design and construction stage. This paper describes economic and operational considerations being used in the development and design of plants utilizing air cooled phosphoric acid fuel cells. Fuel cell power plants have some unique characteristics relative to other types of power plants. As a result it was necessary to develop specific definitions of the fuel cell power plant characteristics in order to perform cost of electricity calculations. This paper describes these characteristics and describes the economic analyses used in the Westinghouse fuel cell power plant program.
2017-03-01
determine the optimum required operational capability of the unmanned aerial vehicles to support Korean rear area operations. We use Map Aware Non ...area operations. Through further experimentations and analyses, we were able to find the optimum characteristics of an improved unmanned aerial...operations. We use Map Aware Non -Uniform Automata, an agent-based simulation software platform for computational experiments. The study models a scenario
Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G
2018-03-01
Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.
District Survey I. Policy Research Corporation Analyses. Final Report.
ERIC Educational Resources Information Center
Policy Research Corp., Chicago, IL.
This study, mandated by Congress in the Education Amendments of 1974, was designed to produce estimates which describe the goals of compensatory programs, program operating characteristics, and evaluation techniques in use in compensatory programs. For the purpose of the study, the population sample was defined as all operating public school…
The ultimate efficiency of photosensitive systems
NASA Technical Reports Server (NTRS)
Buoncristiani, A. M.; Byvik, C. E.; Smith, B. T.
1981-01-01
These systems have in common two important but not independent features: they can produce a storable fuel, and they are sensitive only to radiant energy with a characteristic absorption spectrum. General analyses of the conversion efficiencies were made using the operational characteristics of each particular system. An efficiency analysis of a generalized system consisting of a blackbody source, a radiant energy converter having a threshold energy and operating temperature, and a reservoir is reported. This analysis is based upon the first and second laws of thermodynamics, and leads to a determination of the limiting or ultimate efficiency for an energy conversion system having a characteristic threshold.
NASA Astrophysics Data System (ADS)
Liu, Lei; Huang, Chuanhui; Yu, Ping; Zhang, Lei
2017-10-01
To improve the dynamic characteristics and cavitation characteristics of large-flow pilot operated check valve, consider the pilot poppet as the research object, analyses working principle and design three different kinds of pilot poppets. The vibration characteristics and impact characteristics are analyzed. The simulation model is established through flow field simulation software. The cavitation characteristics of large-flow pilot operated check valve are studied and discussed. On this basis, high-pressure large-flow impact experimental system is used for impact experiment, and the cavitation index is discussed. Then optimal structure is obtained. Simulation results indicate that the increase of pilot poppet half cone angle can effectively reduce the cavitation area, reducing the generation of cavitation. Experimental results show that the pressure impact is not decreasing with increasing of pilot poppet half cone angle in process of unloading, but the unloading capacity, response speed and pilot poppet half cone angle are positively correlated. The impact characteristics of 60° pilot poppet, and its cavitation index is lesser, which indicates 60° pilot poppet is the optimal structure, with the theory results are basically identical.
An aluminum heat sink and radiator for electrophoresis capillaries.
Rapp, T L; Morris, M D
1996-12-15
An aluminum heat sink and radiator are used with forced air cooling of an electrophoresis capillary. Theoretical analyses of the operating limits and heat dissipation characteristics are presented. A system designed for power dissipation as high as 5 W is shown to dissipate heat efficiently and to operate without arcing at voltages higher than 30 kV.
Validation and Verification of Operational Land Analysis Activities at the Air Force Weather Agency
NASA Technical Reports Server (NTRS)
Shaw, Michael; Kumar, Sujay V.; Peters-Lidard, Christa D.; Cetola, Jeffrey
2011-01-01
The NASA developed Land Information System (LIS) is the Air Force Weather Agency's (AFWA) operational Land Data Assimilation System (LDAS) combining real time precipitation observations and analyses, global forecast model data, vegetation, terrain, and soil parameters with the community Noah land surface model, along with other hydrology module options, to generate profile analyses of global soil moisture, soil temperature, and other important land surface characteristics. (1) A range of satellite data products and surface observations used to generate the land analysis products (2) Global, 1/4 deg spatial resolution (3) Model analysis generated at 3 hours
NASA Technical Reports Server (NTRS)
Miller, L. S.
1977-01-01
A number of GEOS-3 passes over the Atlantic Ocean and Southeastern U.S. are examined. Surface-truth and radar altimeter data comparisons are given in terms of surface correlation length, signal fluctuation characteristics, and altitude tracker dynamic response. Detailed analyses are given regarding spatial resolution and its dependency on angular backscatter behavior. These analyses include data from passes over ocean (diffuse scatter), land (large body scatter), and mirror-like inland water areas (pseudo-specular scatter). Altimeter data are examined for a pass over a large reservoir and marsh area of differing water levels; this geometry represents a stepchange in altitude which is usable in determination of the transient response of the tracker. The extent to which pulse-length limited operation pertains over-land is examined. A Wiener filter altitude algorithm is discussed which permits specification of tracker variance and geoidal spectral characteristics during operation.
Study on optimal design of 210kW traction IPMSM considering thermal demagnetization characteristics
NASA Astrophysics Data System (ADS)
Kim, Young Hyun; Lee, Seong Soo; Cheon, Byung Chul; Lee, Jung Ho
2018-04-01
This study analyses the permanent magnet (PM) used in the rotor of an interior permanent magnet synchronous motor (IPMSM) used for driving an electric railway vehicle (ERV) in the context of controllable shape, temperature, and external magnetic field. The positioning of the inserted magnets is a degree of freedom in the design of such machines. This paper describes a preliminary analysis using parametric finite-element method performed with the aim of achieving an effective design. Next, features of the experimental design, based on methods such as the central-composition method, Box-Behnken and Taguchi method, are explored to optimise the shape of the high power density. The results are used to produce an optimal design for IPMSMs, with design errors minimized using Maxwell 2D, a commercial program. Furthermore, the demagnetization process is analysed based on the magnetization and demagnetization theory for PM materials in computer simulation. The result of the analysis can be used to calculate the magnetization and demagnetization phenomenon according to the input B-H curve. This paper presents the conditions for demagnetization by the external magnetic field in the driving and stopped states, and proposes a simulation method that can analyse demagnetization phenomena according to each condition and design the IPMSM that maximizes efficiency and torque characteristics. Finally, operational characteristics are analysed in terms of the operation patterns of railway vehicles, and control conditions are deduced to achieve maximum efficiency in all sections. This was experimentally verified.
Strength and dynamic characteristics analyses of wound composite axial impeller
NASA Astrophysics Data System (ADS)
Wang, Jifeng; Olortegui-Yume, Jorge; Müller, Norbert
2012-03-01
A low cost, light weight, high performance composite material turbomachinery impeller with a uniquely designed blade patterns is analyzed. Such impellers can economically enable refrigeration plants to use water as a refrigerant (R718). A strength and dynamic characteristics analyses procedure is developed to assess the maximum stresses and natural frequencies of these wound composite axial impellers under operating loading conditions. Numerical simulation using FEM for two-dimensional and three-dimensional impellers was investigated. A commercially available software ANSYS is used for the finite element calculations. Analysis is done for different blade geometries and then suggestions are made for optimum design parameters. In order to avoid operating at resonance, which can make impellers suffer a significant reduction in the design life, the designer must calculate the natural frequency and modal shape of the impeller to analyze the dynamic characteristics. The results show that using composite Kevlar fiber/epoxy matrix enables the impeller to run at high tip speed and withstand the stresses, no critical speed will be matched during start-up and shut-down, and that mass imbalances of the impeller shall not pose a critical problem.
Operations Analysis of the 2nd Generation Reusable Launch Vehicle
NASA Technical Reports Server (NTRS)
Noneman, Steven R.; Smith, C. A. (Technical Monitor)
2002-01-01
The Space Launch Initiative (SLI) program is developing a second-generation reusable launch vehicle. The program goals include lowering the risk of loss of crew to 1 in 10,000 and reducing annual operations cost to one third of the cost of the Space Shuttle. The SLI missions include NASA, military and commercial satellite launches and crew and cargo launches to the space station. The SLI operations analyses provide an assessment of the operational support and infrastructure needed to operate candidate system architectures. Measures of the operability are estimated (i.e. system dependability, responsiveness, and efficiency). Operations analysis is used to determine the impact of specific technologies on operations. A conceptual path to reducing annual operations costs by two thirds is based on key design characteristics, such as reusability, and improved processes lowering labor costs. New operations risks can be expected to emerge. They can be mitigated with effective risk management with careful identification, assignment, tracking, and closure. SLI design characteristics such as nearly full reusability, high reliability, advanced automation, and lowered maintenance and servicing coupled with improved processes are contributors to operability and large operating cost reductions.
Inlet Flow Valve Engine Analyses
NASA Technical Reports Server (NTRS)
Champagne, G. A.
2004-01-01
Pratt&Whitney, under Task Order 13 of the NASA Large Engine Technology (LET) Contract, conducted a study to determine the operating characteristics, performance and weights of Inlet Flow Valve (IFV) propulsion concepts for a Mach 2.4 High Speed Civil Transport (HSCT).
Gas-driven pump for ground-water samples
Signor, Donald C.
1978-01-01
Observation wells installed for artificial-recharge research and other wells used in different ground-water programs are frequently cased with small-diameter steel pipe. To obtain samples from these small-diameter wells in order to monitor water quality, and to calibrate solute-transport models, a small-diameter pump with unique operating characteristics is required that causes a minimum alternation of samples during field sampling. A small-diameter gas-driven pump was designed and built to obtain water samples from wells of two-inch diameter or larger. The pump is a double-piston type with the following characteristics: (1) The water sample is isolated from the operating gas, (2) no source of electricity is ncessary, (3) operation is continuous, (4) use of compressed gas is efficient, and (5) operation is reliable over extended periods of time. Principles of operation, actual operation techniques, gas-use analyses and operating experience are described. Complete working drawings and a component list are included. Recent modifications and pump construction for high-pressure applications also are described. (Woodard-USGS)
Novel bidirectional DC-DC converters based on the three-state switching cell
NASA Astrophysics Data System (ADS)
da Silva Júnior, José Carlos; Robles Balestero, Juan Paulo; Lessa Tofoli, Fernando
2016-05-01
It is well known that there is an increasing demand for bidirectional DC-DC converters for applications that range from renewable energy sources to electric vehicles. Within this context, this work proposes novel DC-DC converter topologies that use the three-state switching cell (3SSC), whose well-known advantages over conventional existing structures are ability to operate at high current levels, while current sharing is maintained by a high frequency transformer; reduction of cost and dimensions of magnetics; improved distribution of losses, with consequent increase of global efficiency and reduction of cost associated to the need of semiconductors with lower current ratings. Three distinct topologies can be derived from the 3SSC: one DC-DC converter with reversible current characteristic able to operate in the first and second quadrants; one DC-DC converter with reversible voltage characteristic able to operate in the first and third quadrants and one DC-DC converter with reversible current and voltage characteristics able to operate in four quadrants. Only the topology with bidirectional current characteristic is analysed in detail in terms of the operating stages in both nonoverlapping and overlapping modes, while the design procedure of the power stage elements is obtained. In order to validate the theoretical assumptions, an experimental prototype is also implemented, so that relevant issues can be properly discussed.
1977-07-01
SYSTEM EVOLUTION 4- LEVEL 1 LEVEL 2 LEVEL 3 ,_J LEVEL 4 PERSONNEL ENTRY FACTORS (SKILL, KNOWLEDGE, EXPERIENCE ) HIGH HIGH AND ABOVE...system) and their associated program characteristics (cost, schedules, and operational parameters) based on a combination of analyses, experiments , and...Naval Operations Appropriations (blue doll ars) Appropriation Abbreviation Sponsor Research, Development, Test and Evaluation, Navy RDT&EN ASN (R&D
Thermal-hydraulic analysis capabilities and methods development at NYPA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feltus, M.A.
1987-01-01
The operation of a nuclear power plant must be regularly supported by various thermal-hydraulic (T/H) analyses that may include final safety analysis report (FSAR) design basis calculations and licensing evaluations and conservative and best-estimate analyses. The development of in-house T/H capabilities provides the following advantages: (a) it leads to a better understanding of the plant design basis and operating characteristics; (b) methods developed can be used to optimize plant operations and enhance plant safety; (c) such a capability can be used for design reviews, checking vendor calculations, and evaluating proposed plant modifications; and (d) in-house capability reduces the cost ofmore » analysis. This paper gives an overview of the T/H capabilities and current methods development activity within the engineering department of the New York Power Authority (NYPA) and will focus specifically on reactor coolant system (RCS) transients and plant dynamic response for non-loss-of-coolant accident events. This paper describes NYPA experience in performing T/H analyses in support of pressurized water reactor plant operation.« less
Overview of Chinese GRAPES Data Assimilation System
NASA Astrophysics Data System (ADS)
Liu, Yan
2017-04-01
The development of data assimilation system of Global and Regional Assimilation and Prediction System (GRAPES in short) which is Chinese new generation operational numerical weather prediction system completed in recent years is reviewed in this paper, including the design scheme and main characteristics. GRAPES adopts the variational approach with stresses at application of various remote sensing observational data. Its development path is from three dimensional to four dimensional assimilation. It may be implemented with limited area or global configurations. The three dimensional variational data assimilation systems have been operational in the national and a few of regional meteorological centers. The global four dimensional assimilation system is in pre-operational experiments, and will be upgraded. After a brief introduction to the GRAPES data assimilation system, results of a series of validations of GRAPES analyses against the observation data and analyses derived from other operational NWP center to assess its performance are presented.
Prediction of Advisability of Returning Home Using the Home Care Score
Matsugi, Akiyoshi; Tani, Keisuke; Tamaru, Yoshiki; Yoshioka, Nami; Yamashita, Akira; Mori, Nobuhiko; Oku, Kosuke; Ikeda, Masashi; Nagano, Kiyoshi
2015-01-01
Purpose. The aim of this study was to assess whether the home care score (HCS), which was developed by the Ministry of Health and Welfare in Japan in 1992, is useful for the prediction of advisability of home care. Methods. Subjects living at home and in assisted-living facilities were analyzed. Binominal logistic regression analyses, using age, sex, the functional independence measure score, and the HCS, along with receiver operating characteristic curve analyses, were conducted. Findings/Conclusions. Only HCS was selected for the regression equation. Receiver operating characteristic curve analysis revealed that the area under the curve (0.9), sensitivity (0.82), specificity (0.83), and positive predictive value (0.84) for HCS were higher than those for the functional independence measure, indicating that the HCS is a powerful predictor for advisability of home care. Clinical Relevance. Comprehensive measurements of the condition of provided care and the activities of daily living of the subjects, which are included in the HCS, are required for the prediction of advisability of home care. PMID:26491568
Valid randomization-based p-values for partially post hoc subgroup analyses.
Lee, Joseph J; Rubin, Donald B
2015-10-30
By 'partially post-hoc' subgroup analyses, we mean analyses that compare existing data from a randomized experiment-from which a subgroup specification is derived-to new, subgroup-only experimental data. We describe a motivating example in which partially post hoc subgroup analyses instigated statistical debate about a medical device's efficacy. We clarify the source of such analyses' invalidity and then propose a randomization-based approach for generating valid posterior predictive p-values for such partially post hoc subgroups. Lastly, we investigate the approach's operating characteristics in a simple illustrative setting through a series of simulations, showing that it can have desirable properties under both null and alternative hypotheses. Copyright © 2015 John Wiley & Sons, Ltd.
Design considerations for a Space Shuttle Main Engine turbine blade made of single crystal material
NASA Technical Reports Server (NTRS)
Abdul-Aziz, A.; August, R.; Nagpal, V.
1993-01-01
Nonlinear finite-element structural analyses were performed on the first stage high-pressure fuel turbopump blade of the Space Shuttle Main Engine. The analyses examined the structural response and the dynamic characteristics at typical operating conditions. Single crystal material PWA-1480 was considered for the analyses. Structural response and the blade natural frequencies with respect to the crystal orientation were investigated. The analyses were conducted based on typical test stand engine cycle. Influence of combined thermal, aerodynamic, and centrifugal loadings was considered. Results obtained showed that the single crystal secondary orientation effects on the maximum principal stresses are not highly significant.
Second branchial cleft fistulae: patient characteristics and surgical outcome.
Kajosaari, Lauri; Mäkitie, Antti; Salminen, Päivi; Klockars, Tuomas
2014-09-01
Second branchial cleft anomalies predispose to recurrent infections, and surgical resection is recommended as the treatment of choice. There is no clear consensus regarding the timing or surgical technique in the operative treatment of these anomalies. Our aim was to compare the effect of age and operative techniques to patient characteristics and treatment outcome. A retrospective study of pediatric patients treated for second branchial sinuses or fistulae during 1998-2012 at two departments in our academic tertiary care referral center. Comparison of patient characteristics, preoperative investigations, surgical techniques and postoperative sequelae. Our data is based on 68 patients, the largest series in the literature. One-fourth (24%) of patients had any infectious symptoms prior to operative treatment. Patient demographics, preoperative investigations, use of methylene blue, or tonsillectomy had no effect on the surgical outcome. There were no re-operations due to residual disease. Three complications were observed postoperatively. Our patient series of second branchial cleft sinuses/fistulae is the largest so far and enables analyses of patient characteristics and surgical outcomes more reliably than previously. Preoperative symptoms are infrequent and mild. There was no difference in clinical outcome between the observed departments. Performing ipsilateral tonsillectomy gave no outcome benefits. The operation may be delayed to an age of approximately three years when anesthesiological risks are and possible harms are best avoided. Considering postoperative pain and risk of postoperative hemorrhage a routine tonsillectomy should not be included to the operative treatment of second branchial cleft fistulae. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Diagnostic Utility of the Social Skills Improvement System Performance Screening Guide
ERIC Educational Resources Information Center
Krach, S. Kathleen; McCreery, Michael P.; Wang, Ye; Mohammadiamin, Houra; Cirks, Christen K.
2017-01-01
Researchers investigated the diagnostic utility of the Social Skills Improvement System: Performance Screening Guide (SSIS-PSG). Correlational, regression, receiver operating characteristic (ROC), and conditional probability analyses were run to compare ratings on the SSIS-PSG subscales of Prosocial Behavior, Reading Skills, and Math Skills, to…
Recognition Memory: Adding a Response Deadline Eliminates Recollection but Spares Familiarity
ERIC Educational Resources Information Center
Sauvage, Magdalena M.; Beer, Zachery; Eichenbaum, Howard
2010-01-01
A current controversy in memory research concerns whether recognition is supported by distinct processes of familiarity and recollection, or instead by a single process wherein familiarity and recollection reflect weak and strong memories, respectively. Recent studies using receiver operating characteristic (ROC) analyses in an animal model have…
NASA Astrophysics Data System (ADS)
Cao, Dongpu; Khajepour, Amir; Song, Xubin
2011-08-01
Flexible-wheel (FW) suspension concept has been regarded to be one of the novel technologies for future planetary surface vehicles (PSVs). This study develops generalised models for fundamental stiffness and damping properties and power consumption characteristics of the FW suspension with and without considering wheel-hub dimensions. Compliance rolling resistance (CRR) coefficient is also defined and derived for the FW suspension. Based on the generalised models and two dimensionless measures, suspension properties are analysed for two FW suspension configurations. The sensitivity analysis is performed to investigate the effects of the design parameters and operating conditions on the CRR and power consumption characteristic of the FW suspension. The modelling generalisation permits analyses of fundamental properties and power consumption characteristics of different FW suspension designs in a uniform and very convenient manner, which would serve as a theoretical foundation for the design of FW suspensions for future PSVs.
Daci, Armond; Bozalija, Adnan; Cavolli, Raif; Alaj, Rame; Beretta, Giangiacomo; Krasniqi, Shaip
2018-01-01
BACKGROUND: Coronary Artery Bypass Grafting (CABG) is realised in patients with critical or advanced disease of coronary arteries. There are different pharmacotherapeutic approaches which are used as management, treatment and preventive therapy in cardiovascular disease or related comorbidities. Performing a successful surgery, pharmacotherapy, and increase of bypass patency rate remains a serious challenge. AIM: This study aims to analyse the patient characteristics undergoing CABG and evaluation of their drug utilisation rate and daily dosages in the perioperative period. MATERIAL AND METHODS: Data were collected from 102 patients in the period 2016-2017 and detailed therapeutic prescription and dosages, patient characteristics were analysed before the operation, after the operation and visit after operation in the Clinic of Cardiac surgery-University Clinical Center of Kosovo. RESULTS: Our findings had shown that patients provided to have normal biochemical parameters in the clinic before the operation, and were related to cardiovascular diseases and comorbidities and risk factors with mainly elective intervention. The, however, higher utilisation of cardiovascular drugs such as beta blockers, diuretics, anticoagulants, statins and lower calcium blockers, ACEi, ARBs, hydrochlorothiazide, amiodarone were founded. ARBs, beta blockers, statins, nitrates and nadroparin utilisation decreased after operation and visit after the operation, whereas amiodarone only in the visit after the operation. Diuretics are increased after the operation which decreases in the visit after the operation. Regarding the daily dosage, only metoprolol was increased in the visit after operation (P < 0.001) and visit after operation (P < 0.05) whereas losartan and furosemide were increased (P < 0.01) and (P < 0.05) respectively. CONCLUSION: The study showed that beta blockers, statins, aspirin, nitrates (before the operation), furosemide and spironolactone are the most utilised drugs. However, we found low utilisation rate for ACEi, ARBs, clopidogrel, nadroparin, warfarin, xanthines, amiodarone, calcium blockers. Daily dosages were different compared to before CABG only in metoprolol, losartan, and furosemide. PMID:29610608
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Seungmok; Seong, Heeje
In this paper, experimental analyses are conducted into the GDI soot oxidation characteristics as dependent on engine operating conditions. Soot is sampled at various engine operating conditions of a commercial 2.4 L GDI engine with a naturally aspirated, homogeneous, and stoichiometric operation strategy. The oxidation reactivity, ash composition, and carbon nanostructure of the GDI soot samples are analyzed using thermogravimetric analysis (TGA), scanning electron microscope–energy-dispersive spectroscopy (SEM-EDS), high-resolution transmission electron microscopy (HR-TEM), and Raman spectroscopy. Based on the analyses, a global GDI soot oxidation mechanism is proposed which includes the effects of soluble organic fractions (SOF)/weakly bonded carbon (WBC), andmore » three types of ash on GDI soot oxidation. The results show that GDI soot contains an order of magnitude higher ash fraction than does conventional diesel soot, and oxidation reactivity is significantly enhanced by the catalytic effects of ash, as a function of ash content in soot. A modified empirical kinetic correlation for GDI soot oxidation is suggested on the basis of the results, and the modified kinetic correlation predicts the GDI soot oxidation rate accurately for various engine operation points at wide ranges of soot conversion and temperature without modifying kinetic parameters. The kinetic parameters are determined from isothermal and non-isothermal thremogravimetric analysis (TGA) soot oxidation tests; the methods are elucidated in detail.« less
Choi, Seungmok; Seong, Heeje
2015-03-02
In this paper, experimental analyses are conducted into the GDI soot oxidation characteristics as dependent on engine operating conditions. Soot is sampled at various engine operating conditions of a commercial 2.4 L GDI engine with a naturally aspirated, homogeneous, and stoichiometric operation strategy. The oxidation reactivity, ash composition, and carbon nanostructure of the GDI soot samples are analyzed using thermogravimetric analysis (TGA), scanning electron microscope–energy-dispersive spectroscopy (SEM-EDS), high-resolution transmission electron microscopy (HR-TEM), and Raman spectroscopy. Based on the analyses, a global GDI soot oxidation mechanism is proposed which includes the effects of soluble organic fractions (SOF)/weakly bonded carbon (WBC), andmore » three types of ash on GDI soot oxidation. The results show that GDI soot contains an order of magnitude higher ash fraction than does conventional diesel soot, and oxidation reactivity is significantly enhanced by the catalytic effects of ash, as a function of ash content in soot. A modified empirical kinetic correlation for GDI soot oxidation is suggested on the basis of the results, and the modified kinetic correlation predicts the GDI soot oxidation rate accurately for various engine operation points at wide ranges of soot conversion and temperature without modifying kinetic parameters. The kinetic parameters are determined from isothermal and non-isothermal thremogravimetric analysis (TGA) soot oxidation tests; the methods are elucidated in detail.« less
Strategies for the study of flightcrew behavior
NASA Technical Reports Server (NTRS)
Helmreich, Robert L.
1991-01-01
The performance of any flightcrew at any given time is determined by multiple factors ranging from characteristics of individual crewmembers to the regulations governing flight operations. Attention is given to microcoding of communications, survey data on crewmember attitudes as indicators of culture and crew resource management (CRM) training effects, and systematic observation of crew behavior. Consideration is given to advanced CRM training of evaluators, analyses of crew behavior by aircraft type and characteristics, and survey data on crew reactions to line oriented flight training.
Dual nozzle aerodynamic and cooling analysis study
NASA Technical Reports Server (NTRS)
Meagher, G. M.
1981-01-01
Analytical models to predict performance and operating characteristics of dual nozzle concepts were developed and improved. Aerodynamic models are available to define flow characteristics and bleed requirements for both the dual throat and dual expander concepts. Advanced analytical techniques were utilized to provide quantitative estimates of the bleed flow, boundary layer, and shock effects within dual nozzle engines. Thermal analyses were performed to define cooling requirements for baseline configurations, and special studies of unique dual nozzle cooling problems defined feasible means of achieving adequate cooling.
Kim, Jaeyoun; Soref, Richard; Buchwald, Walter R
2010-08-16
We investigate the electromagnetic response of the concentric multi-ring, or the bull's eye, structure as an extension of the dual-ring metamaterial which exhibits electromagnetically-induced transparency (EIT)-like transmission characteristics. Our results show that adding inner rings produces additional EIT-like peaks, and widens the metamaterial's spectral range of operation. Analyses of the dispersion characteristics and induced current distribution further confirmed the peak's EIT-like nature. Impacts of structural and dielectric parameters are also investigated.
Investigation of hazards associated with plastic bonded starter mix manufacturing processes
NASA Technical Reports Server (NTRS)
1971-01-01
An investigation to determine the hazards potential evaluation of plastic bonded starter mix (PBSM) production processes and the application to the M18 and M7A3 grenades is reported. The investigation indicated: (1) the materials with the greatest hazards characteristics, (2) process operating stations most likely to initiate hazardous conditions, (3) the test program required to examine ignition characteristics and process hazards, and (4) the method of handling the accumulated information from testing and safety analyses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Picologlou, B F; Batenin, V M
1981-01-01
A description of the main results obtained during Tests No. 6 and 7 at the U-25B Facility using the new channel No. 2 is presented. The purpose of these tests was to operate the MHD generator at its design parameters. Described here are new plasma diagnostic devices: a traversing dual electrical probe for determining distribution of electron concentrations, and a traversing probe that includes a pitot tube for measuring total and static pressure, and a light detector for measuring plasma luminescence. Data are presented on heat flux distribution along the channel, the first data of this type obtained for anmore » MHD facility of such size. Results are given of experimental studies of plasma characteristics, gasdynamic, thermal, and electrical MHD channel performance, and temporal and spatial nonuniformities. Typical modes of operation are analyzed by means of local electrical analyses. Computer models are used to obtain predictions for both localized and overall generator characteristics. These theoretical predictions agree closely with the results of the local analyses, as well as with measurements of the overall gasdynamic and electrical characteristics of the generator.« less
Discharge Characteristics of DC Arc Water Plasma for Environmental Applications
NASA Astrophysics Data System (ADS)
Li, Tianming; Sooseok, Choi; Takayuki, Watanabe
2012-12-01
A water plasma was generated by DC arc discharge with a hafnium embedded rod-type cathode and a nozzle-type anode. The discharge characteristics were examined by changing the operation parameter of the arc current. The dynamic behavior of the arc discharge led to significant fluctuations in the arc voltage and its frequency. Analyses of the high speed image and the arc voltage waveform showed that the arc discharge was in the restrike mode and its frequency varied within several tens of kilohertz according to the operating conditions. The larger thermal plasma volume was generated by the higher flow from the forming steam with a higher restrike frequency in the higher arc current conditions. In addition, the characteristics of the water plasma jet were investigated by means of optical emission spectroscopy to identify the abundant radicals required in an efficient waste treatment process.
Leadership and characteristics of nonprofit mental health peer-run organizations nationwide.
Ostrow, Laysha; Hayes, Stephania L
2015-04-01
Mental health peer-run organizations are nonprofits providing venues for support and advocacy among people diagnosed as having mental disorders. It has been proposed that consumer involvement is essential to their operations. This study reported organizational characteristics of peer-run organizations nationwide and how these organizations differ by degree of consumer control. Data were from the 2012 National Survey of Peer-Run Organizations. The analyses described the characteristics of the organizations (N=380) on five domains of nonprofit research, comparing results for organizations grouped by degree of involvement by consumers in the board of directors. Peer-run organizations provided a range of supports and educational and advocacy activities and varied in their capacity and resources. Some variation was explained by the degree of consumer control. These organizations seemed to be operating consistently with evidence on peer-run models. The reach of peer-run organizations, and the need for in-depth research, continues to grow.
Future of Mechatronics and Human
NASA Astrophysics Data System (ADS)
Harashima, Fumio; Suzuki, Satoshi
This paper mentions circumstance of mechatronics that sustain our human society, and introduces HAM(Human Adaptive Mechatronics)-project as one of research projects to create new human-machine system. The key point of HAM is skill, and analysis of skill and establishment of assist method to enhance total performance of human-machine system are main research concerns. As study of skill is an elucidation of human itself, analyses of human higher function are significant. In this paper, after surveying researches of human brain functions, an experimental analysis of human characteristic in machine operation is shown as one example of our research activities. We used hovercraft simulator as verification system including observation, voluntary motion control and machine operation that are needed to general machine operation. Process and factors to become skilled were investigated by identification of human control characteristics with measurement of the operator's line-of sight. It was confirmed that early switching of sub-controllers / reference signals in human and enhancement of space perception are significant.
Niederer, Daniel; Vogt, Lutz; Wilke, Jan; Rickert, Marcus; Banzer, Winfried
2015-03-01
The present study aims to develop age-dependent cutoff values in a quasi-experimental, cross-sectional diagnostic test study. One hundred and twenty (120) asymptomatic subjects (n = 100, 36♀, 18 75 years, for normative values; n = 20, 23-75 years, 15♀, for selectivity analyses) and 20 patients suffering from idiopathic neck pain (selectivity analyses, 22-71 years, 15♀) were included. Subjects performed five repetitive maximal cervical flexion/extension movements in an upright sitting position. Cervical kinematic characteristics (maximal range of motion (ROM), coefficient of variation (CV) and mean conjunct movements in rotation and flexion (CM)) were calculated from raw 3D ultrasonic data. Regression analyses were conducted to reveal associations between kinematic characteristics and age and gender and thus to determine normative values for healthy subjects. Age explains 53 % of the variance in ROM (decrease 10.2° per decade), 13 % in CV (increase 0.003 per decade) and 9 % in CM (increase 0.57° per decade). Receivers operating characteristic (ROC) analyses were conducted for differences between individual values of the kinematic characteristics and normative values to optimise cutoff values for distinguishing patients from unimpaired subjects (20 patients and 20 healthy). Cutoff values distinguished asymptomatic subjects' and chronic nonspecific neck patient's movement characteristics with sufficient quality (sensitivity 70-80 %, specificity 65-70 %). By including such classifications, the present findings expand actual research stating an age-related decrease in kinematic behaviour only using categorising span widths across decades. Future study is warranted to reveal our results' potential applicability for intervention onset decision making for idiopathic neck pain patients.
Recognition Errors Suggest Fast Familiarity and Slow Recollection in Rhesus Monkeys
ERIC Educational Resources Information Center
Basile, Benjamin M.; Hampton, Robert R.
2013-01-01
One influential model of recognition posits two underlying memory processes: recollection, which is detailed but relatively slow, and familiarity, which is quick but lacks detail. Most of the evidence for this dual-process model in nonhumans has come from analyses of receiver operating characteristic (ROC) curves in rats, but whether ROC analyses…
Salia, Shemsedin Musefa; Mersha, Hagos Biluts; Aklilu, Abenezer Tirsit; Baleh, Abat Sahlu; Lund-Johansen, Morten
2018-06-01
Compound depressed skull fracture (DSF) is a neurosurgical emergency. Preoperative knowledge of dural status is indispensable for treatment decision making. This study aimed to determine predictors of dural tear from clinical and imaging characteristics in patients with compound DSF. This prospective, multicenter correlational study in neurosurgical hospitals in Addis Ababa, Ethiopia, included 128 patients operated on from January 1, 2016, to October 31, 2016. Clinical, imaging, and intraoperative findings were evaluated. Univariate and multivariate analyses were used to establish predictors of dural tear. A logistic regression model was developed to predict probability of dural tear. Model validation was done using the receiver operating characteristic curve. Dural tear was seen in 55.5% of 128 patients. Demographics, injury mechanism, clinical presentation, and site of DSF had no significant correlation with dural tear. In univariate and multivariate analyses, depth of fracture depression (odds ratio 1.3, P < 0.001), pneumocephalus (odds ratio 2.8, P = 0.005), and brain contusions/intracerebral hematoma (odds ratio 5.5, P < 0.001) were significantly correlated with dural tear. We developed a logistic regression model (diagnostic test) to calculate probability of dural tear. Using the receiver operating characteristic curve, we determined the cutoff value for a positive test giving the highest accuracy to be 30% with a corresponding sensitivity of 93.0% and specificity of 43.9%. Dural tear in compound DSF can be predicted with 93.0% sensitivity using preoperative findings and may guide treatment decision making in resource-limited settings where risk of extensive cranial surgery outweighs the benefit. Copyright © 2018 Elsevier Inc. All rights reserved.
2010-10-01
mission, participants were given the NASA Task Load Index ( NASA TLX ) to measure subjective workload. Additional performance measures included mission...16 NASA TLX Workload Analyses...worksheet (See Appendix C), the Hidden Patterns Test (ETS, 1976), and an electronic form of the NASA Task Load Index ( TLX ; Hart & Staveland, 1988). The
The Relation between DIBELS, Reading Comprehension, and Vocabulary in Urban First-Grade Students
ERIC Educational Resources Information Center
Riedel, Brant W.
2007-01-01
The relation between Dynamic Indicators of Basic Early Literacy Skills (DIBELS) and reading comprehension at the end of first grade and second grade was examined in a sample of 1,518 first-grade students from a large urban school district. Receiver Operating Characteristic (ROC) analyses were used to determine optimal DIBELS cut scores for…
Multi-mission Ni-H2 battery cell for the 1990's
NASA Technical Reports Server (NTRS)
Miller, Lee; Brill, Jack; Dodson, Gary
1989-01-01
A sufficient production, test and operational database is now available to permit design technology optimization for the next decade. The evolved battery cell design features standardized technology intended to support multiple type missions (e.g., both GEO and LEO). Design analyses and validation test cells demonstrate improved performance plus attractive specific-energy characteristics will be achieved.
de Souza, Vanessa; Zeitoun, Sandra Salloum; Lopes, Camila Takao; de Oliveira, Ana Paula Dias; Lopes, Juliana de Lima; de Barros, Alba Lucia Bottura Leite
2015-09-01
To assess the clinical usefulness of the operational definitions for the defining characteristics of the NANDA International nursing diagnoses, activity intolerance, decreased cardiac output and excess fluid volume, and the concomitant presence of those diagnoses in patients with decompensated heart failure. Content validity of the operational definitions for the defining characteristics of activity intolerance, excess fluid volume and decreased cardiac output have been previously validated by experts. Their clinical usefulness requires clinical validation. This was a descriptive exploratory study. Two expert nurses independently assessed 25 patients with decompensated heart failure for the presence or absence of 29 defining characteristics. Interrater reliability was analysed using the Kappa coefficient as a measure of clinical usefulness. The Fisher's exact test was used to test the association of the defining characteristics of activity intolerance and excess fluid volume in the presence of decreased cardiac output, and the correlation between the three diagnoses. Assessments regarding the presence of all defining characteristics reached 100% agreement, except with anxiety. Five defining characteristics of excess fluid volume were significantly associated with the presence of decreased cardiac output. Concomitant presence of the three diagnoses occurred in 80% of the patients. However, there was no significant correlation between the three diagnoses. The operational definitions for the diagnoses had strong interrater reliability, therefore they were considered clinically useful. Only five defining characteristics were representative of the association between excess fluid volume and decreased cardiac output. Therefore, excess fluid volume is related to decreased cardiac output, although these diagnoses are not necessarily associated with activity intolerance. The operational definitions may favour early recognition of the sequence of responses to decompensation, guiding the choice of common interventions to improve or resolve excess fluid volume and decreased cardiac output. © 2015 John Wiley & Sons Ltd.
The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.
Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar
2018-03-01
This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility (< 10 cycles per minute), and the difference between near and distance phoria (> 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near phoria, and monocular accommodative facility yield good sensitivity and specificity for diagnosis of NSBVAs in a community set-up. © 2017 Optometry Australia.
Leadership and Characteristics of Nonprofit Mental Health Peer-Run Organizations Nationwide
Ostrow, Laysha; Hayes, Stephania L.
2015-01-01
Objective Mental health peer-run organizations are nonprofits providing venues for support and advocacy among people diagnosed as having mental disorders. It has been proposed that consumer involvement is essential to their operations. This study reported organizational characteristics of peer-run organizations nationwide and how these organizations differ by degree of consumer control. Methods Data were from the 2012 National Survey of Peer-Run Organizations. The analyses described the characteristics of the organizations (N = 380) on five domains of nonprofit research, comparing results for organizations grouped by degree of involvement by consumers in the board of directors. Results Peer-run organizations provided a range of supports and educational and advocacy activities and varied in their capacity and resources. Some variation was explained by the degree of consumer control. Conclusions These organizations seemed to be operating consistently with evidence on peer-run models. The reach of peer-run organizations, and the need for in-depth research, continues to grow. PMID:25639988
Space Shuttle Main Engine (SSME) LOX turbopump pump-end bearing analysis
NASA Technical Reports Server (NTRS)
1986-01-01
A simulation of the shaft/bearing system of the Space Shuttle Main Engine Liquid Oxygen turbopump was developed. The simulation model allows the thermal and mechanical characteristics to interact as a realistic simulation of the bearing operating characteristics. The model accounts for single and two phase coolant conditions, and includes the heat generation from bearing friction and fluid stirring. Using the simulation model, parametric analyses were performed on the 45 mm pump-end bearings to investigate the sensitivity of bearing characteristics to contact friction, axial preload, coolant flow rate, coolant inlet temperature and quality, heat transfer coefficients, outer race clearance and misalignment, and the effects of thermally isolating the outer race from the isolator.
ERIC Educational Resources Information Center
Delgado, Ander
2014-01-01
This article analyses the creation of the schools called "ikastolas" throughout the Basque Country from the 1960s onwards. The name "ikastola" refers to a unique school model whose major characteristic is to teach the majority of subjects in the Basque language, or "euskera." It outlines the reasons why some of these…
Borad, N P; Merchant, A M
2017-12-01
Although studies have implicated smoking as a positive predictor of post-operative outcomes in inguinal hernia repair, its impact on ventral hernia repair (VHR) is not as clear. This study aims to fill this gap by investigating the impact of smoking on developing adverse 30-day post-operative outcomes in VHR. Patients undergoing VHR between 2005 and 2014 were extracted from the American College of Surgeons National Surgical Quality Improvement Program database. Patients were stratified by smoking status and compared for significant differences in baseline characteristics. Logistic regression modeled the impact of smoking on the primary outcome variable of 30-day mortality and the secondary outcome variables of 30-day overall, cardiac, respiratory, or wound morbidity. To evaluate the influence of smoking in comparable groups undergoing VHR, a propensity score matched analysis was performed. Out of 169,458 patients identified, 32,973 (19.5%) were classified as current smokers. Smokers and non/ex-smokers differed significantly in multiple pre-operative baseline characteristics. Unmatched univariate analyses revealed smoking status as a positive predictor of every post-operative outcome. These findings were validated with propensity score matching analyses, which found current smokers have an increased likelihood of 30-day mortality (OR 1.42), overall morbidity (OR 1.39), wound (OR 1.40), respiratory (OR 1.14), or cardiac morbidity (OR 1.88) compared to non/ex-smokers (p < 0.05 for all). Smoking is a modifiable risk factor with a detrimental impact on outcomes in patients undergoing ventral hernia repair. Delaying VHR and promoting smoking cessation prior to surgery may help reduce the odds of adverse 30-day post-operative outcomes.
Aeromechanics Analysis of a Distortion-Tolerant Fan with Boundary Layer Ingestion
NASA Technical Reports Server (NTRS)
Bakhle, Milind A.; Reddy, T. S. R.; Coroneos, Rula M.; Min, James B.; Provenza, Andrew J.; Duffy, Kirsten P.; Stefko, George L.; Heinlein, Gregory S.
2018-01-01
A propulsion system with Boundary Layer Ingestion (BLI) has the potential to significantly reduce aircraft engine fuel burn. But a critical challenge is to design a fan that can operate continuously with a persistent BLI distortion without aeromechanical failure -- flutter or high cycle fatigue due to forced response. High-fidelity computational aeromechanics analysis can be very valuable to support the design of a fan that has satisfactory aeromechanic characteristics and good aerodynamic performance and operability. Detailed aeromechanics analyses together with careful monitoring of the test article is necessary to avoid unexpected problems or failures during testing. In the present work, an aeromechanics analysis based on a three-dimensional, time-accurate, Reynolds-averaged Navier-Stokes computational fluid dynamics code is used to study the performance and aeromechanical characteristics of the fan in both circumferentially-uniform and circumferentially-varying distorted flows. Pre-test aeromechanics analyses are used to prepare for the wind tunnel test and comparisons are made with measured blade vibration data after the test. The analysis shows that the fan has low levels of aerodynamic damping at various operating conditions examined. In the test, the fan remained free of flutter except at one near-stall operating condition. Analysis could not be performed at this low mass flow rate operating condition since it fell beyond the limit of numerical stability of the analysis code. The measured resonant forced response at a specific low-response crossing indicated that the analysis under-predicted this response and work is in progress to understand possible sources of differences and to analyze other larger resonant responses. Follow-on work is also planned with a coupled inlet-fan aeromechanics analysis that will more accurately represent the interactions between the fan and BLI distortion.
Data Processing for the Space-Based Desis Hyperspectral Sensor
NASA Astrophysics Data System (ADS)
Carmona, E.; Avbelj, J.; Alonso, K.; Bachmann, M.; Cerra, D.; Eckardt, A.; Gerasch, B.; Graham, L.; Günther, B.; Heiden, U.; Kerr, G.; Knodt, U.; Krutz, D.; Krawcyk, H.; Makarau, A.; Miller, R.; Müller, R.; Perkins, R.; Walter, I.
2017-05-01
The German Aerospace Center (DLR) and Teledyne Brown Engineering (TBE) have established a collaboration to develop and operate a new space-based hyperspectral sensor, the DLR Earth Sensing Imaging Spectrometer (DESIS). DESIS will provide spacebased hyperspectral data in the VNIR with high spectral resolution and near-global coverage. While TBE provides the platform and infrastructure for operation of the DESIS instrument on the International Space Station, DLR is responsible for providing the instrument and the processing software. The DESIS instrument is equipped with novel characteristics for an imaging spectrometer such high spectral resolution (2.55 nm), a mirror pointing unit or a CMOS sensor operated in rolling shutter mode. We present here an overview of the DESIS instrument and its processing chain, emphasizing the effect of the novel characteristics of DESIS in the data processing and final data products. Furthermore, we analyse in more detail the effect of the rolling shutter on the DESIS data and possible mitigation/correction strategies.
Linear combination methods to improve diagnostic/prognostic accuracy on future observations
Kang, Le; Liu, Aiyi; Tian, Lili
2014-01-01
Multiple diagnostic tests or biomarkers can be combined to improve diagnostic accuracy. The problem of finding the optimal linear combinations of biomarkers to maximise the area under the receiver operating characteristic curve has been extensively addressed in the literature. The purpose of this article is threefold: (1) to provide an extensive review of the existing methods for biomarker combination; (2) to propose a new combination method, namely, the nonparametric stepwise approach; (3) to use leave-one-pair-out cross-validation method, instead of re-substitution method, which is overoptimistic and hence might lead to wrong conclusion, to empirically evaluate and compare the performance of different linear combination methods in yielding the largest area under receiver operating characteristic curve. A data set of Duchenne muscular dystrophy was analysed to illustrate the applications of the discussed combination methods. PMID:23592714
Multimode analysis of highly tunable, quantum cascade powered, circular graphene spaser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jayasekara, Charith, E-mail: charith.jayasekara@monash.edu; Premaratne, Malin; Stockman, Mark I.
2015-11-07
We carried out a detailed analysis of a circular graphene spaser made of a circular graphene flake and a quantum cascade well structure. Owing to unique properties of graphene and quantum cascade well structure, the proposed design shows high mechanical and thermal stability and low optical losses. Additionally, operation characteristics of the model are analysed and tunability of the device is demonstrated. Some advantages of the proposed design include compact size, lower power operation, and the ability to set the operating wavelength over a wide range from Mid-IR to Near-IR. Thus, it can have wide spread applications including designing ofmore » ultracompact and ultrafast devices, nanoscopy and biomedical applications.« less
Liou, Shwu-Ru
2009-01-01
To systematically analyse the Organizational Commitment model and Theory of Reasoned Action and determine concepts that can better explain nurses' intention to leave their job. The Organizational Commitment model and Theory of Reasoned Action have been proposed and applied to understand intention to leave and turnover behaviour, which are major contributors to nursing shortage. However, the appropriateness of applying these two models in nursing was not analysed. Three main criteria of a useful model were used for the analysis: consistency in the use of concepts, testability and predictability. Both theories use concepts consistently. Concepts in the Theory of Reasoned Action are defined broadly whereas they are operationally defined in the Organizational Commitment model. Predictability of the Theory of Reasoned Action is questionable whereas the Organizational Commitment model can be applied to predict intention to leave. A model was proposed based on this analysis. Organizational commitment, intention to leave, work experiences, job characteristics and personal characteristics can be concepts for predicting nurses' intention to leave. Nursing managers may consider nurses' personal characteristics and experiences to increase their organizational commitment and enhance their intention to stay. Empirical studies are needed to test and cross-validate the re-synthesized model for nurses' intention to leave their job.
ERIC Educational Resources Information Center
Agolli, Renata
2015-01-01
This paper aims to introduce pre-CLIL through the CLSL (content & languages [L1/L2] shared learning) model, which operates as a bridge for a full CLIL immersion. It analyses the characteristics of this new learning model that springs up from immanent needs of Italian educational reality by reporting results on the way content and language…
Turboprop cargo aircraft systems study
NASA Technical Reports Server (NTRS)
Muehlbauer, J. C.; Hewell, J. G., Jr.; Lindenbaum, S. P.; Randall, C. C.; Searle, N.; Stone, R. G., Jr.
1981-01-01
The effects of using advanced turboprop propulsion systems to reduce the fuel consumption and direct operating costs of cargo aircraft were studied, and the impact of these systems on aircraft noise and noise prints around a terminal area was determined. Parametric variations of aircraft and propeller characteristics were investigated to determine their effects on noiseprint areas, fuel consumption, and direct operating costs. From these results, three aircraft designs were selected and subjected to design refinements and sensitivity analyses. Three competitive turbofan aircraft were also defined from parametric studies to provide a basis for comparing the two types of propulsion.
Boutin, Amélie; Gasse, Cédric; Demers, Suzanne; Giguère, Yves; Tétu, Amélie; Bujold, Emmanuel
2018-05-01
Low-dose aspirin started in early pregnancy significantly reduces the risk of preeclampsia (PE) in high-risk women, especially preterm PE. This study aimed to evaluate the influence of maternal characteristics on the risk of PE in nulliparous women. The Great Obstetrical Syndromes (GOS) study recruited nulliparous women with singleton pregnancies at 11 to 13 weeks. The following maternal characteristics were collected: age, BMI, ethnicity, chronic diseases, smoking, and assisted reproductive technologies. Relative weight analyses were conducted, and predictive multivariate proportional hazard models were constructed. Receiver operating characteristic curve analyses with their area under the curve (AUC) were used to evaluate the value of each factor for the prediction of PE and preterm PE. The study also evaluated the SOGC guidelines for identification of women at high risk of PE. Of 4739 participants, 232 (4.9%) developed PE, including 30 (0.6%) with preterm PE. In univariate analyses, only BMI was significantly associated with the risk of PE (AUC 0.60; 95% CI 0.55-0.65) and preterm PE (AUC 0.64; 95% CI 054-0.73). Adding other maternal characteristics to BMI had a non-significant and marginal impact on the discriminative ability to the models for PE (AUC 0.62; 95% CI 0.58-0.66) and preterm PE (AUC 0.65; 95% CI 0.56-0.74). At a false-positive rate of 10%, maternal characteristics could have predicted 23% of PE and 19% of preterm PE. The SOGC guidelines were not discriminant for PE (detecting 96% of PE and 93% of preterm PE with a 94% false-positive rate). In nulliparous women, BMI is the most discriminant maternal characteristic for the prediction of PE. Maternal characteristics should not be used alone to identify nulliparous women at high risk of PE. Copyright © 2018 Society of Obstetricians and Gynaecologists of Canada. Published by Elsevier Inc. All rights reserved.
Study on High Efficient Electric Vehicle Wireless Charging System
NASA Astrophysics Data System (ADS)
Chen, H. X.; Liu, Z. Z.; Zeng, H.; Qu, X. D.; Hou, Y. J.
2016-08-01
Electric and unmanned is a new trend in the development of automobile, cable charging pile can not meet the demand of unmanned electric vehicle. Wireless charging system for electric vehicle has a high level of automation, which can be realized by unmanned operation, and the wireless charging technology has been paid more and more attention. This paper first analyses the differences in S-S (series-series) and S-P (series-parallel) type resonant wireless power supply system, combined with the load characteristics of electric vehicle, S-S type resonant structure was used in this system. This paper analyses the coupling coefficient of several common coil structure changes with the moving distance of Maxwell Ansys software, the performance of disc type coil structure is better. Then the simulation model is established by Simulink toolbox in Matlab, to analyse the power and efficiency characteristics of the whole system. Finally, the experiment platform is set up to verify the feasibility of the whole system and optimize the system. Based on the theoretical and simulation analysis, the higher charging efficiency is obtained by optimizing the magnetic coupling mechanism.
NASA Astrophysics Data System (ADS)
Conradie, J. L.; Eisa, M. E. M.; Celliers, P. J.; Delsink, J. L. G.; Fourie, D. T.; de Villiers, J. G.; Maine, P. M.; Springhorn, K. A.; Pineda-Vargas, C. A.
2005-04-01
With the aim of improving the reliability and stability of the beams delivered to the nuclear microprobe at iThemba LABS, as well as optimization of the beam characteristics along the van de Graaff accelerator beamlines in general, relevant modifications were implemented since the beginning of 2003. The design and layout of the beamlines were revised. The beam-optical characteristics through the accelerator, from the ion source up to the analysing magnet directly after the accelerator, were calculated and the design optimised, using the computer codes TRANSPORT, IGUN and TOSCA. The ion source characteristics and optimal operating conditions were determined on an ion source test bench. The measured optimal emittance for 90% of the beam intensity was about 50π mm mrad for an extraction voltage of 6 kV. These changes allow operation of the Nuclear Microprobe at proton energies in the range 1 MeV-4 MeV with beam intensities of tenths of a pA at the target surface. The capabilities of the nuclear microprobe facility were evaluated in the improved beamline, with particular emphasis to bio-medical samples.
Modelling and Analysis of a New Piezoelectric Dynamic Balance Regulator
Du, Zhe; Mei, Xue-Song; Xu, Mu-Xun
2012-01-01
In this paper, a new piezoelectric dynamic balance regulator, which can be used in motorised spindle systems, is presented. The dynamic balancing adjustment mechanism is driven by an in-plane bending vibration from an annular piezoelectric stator excited by a high-frequency sinusoidal input voltage. This device has different construction, characteristics and operating principles than a conventional balance regulator. In this work, a dynamic model of the regulator is first developed using a detailed analytical method. Thereafter, MATLAB is employed to numerically simulate the relations between the dominant parameters and the characteristics of the regulator based on thedynamic model. Finally, experimental measurements are used to certify the validity of the dynamic model. Consequently, the mathematical model presented and analysed in this paper can be used as a tool for optimising the design of a piezoelectric dynamic balance regulator during steady state operation. PMID:23202182
Parametric analyses of planned flowing uranium hexafluoride critical experiments
NASA Technical Reports Server (NTRS)
Rodgers, R. J.; Latham, T. S.
1976-01-01
Analytical investigations were conducted to determine preliminary design and operating characteristics of flowing uranium hexafluoride (UF6) gaseous nuclear reactor experiments in which a hybrid core configuration comprised of UF6 gas and a region of solid fuel will be employed. The investigations are part of a planned program to perform a series of experiments of increasing performance, culminating in an approximately 5 MW fissioning uranium plasma experiment. A preliminary design is described for an argon buffer gas confined, UF6 flow loop system for future use in flowing critical experiments. Initial calculations to estimate the operating characteristics of the gaseous fissioning UF6 in a confined flow test at a pressure of 4 atm, indicate temperature increases of approximately 100 and 1000 K in the UF6 may be obtained for total test power levels of 100 kW and 1 MW for test times of 320 and 32 sec, respectively.
NASA Astrophysics Data System (ADS)
Nakajima, Hironori; Kitahara, Tatsumi
2017-11-01
We have investigated the behavior of an operating solid oxide fuel cell (SOFC) with supplying a simulated syngas to develop diagnosis method of the SOFC for marine power applications fueled with liquefied natural gas (LNG). We analyze the characteristics of a syngas-fueled intermediate temperature microtubular SOFC at 500 ∘C for accelerated deterioration by carbon deposition as a model case by electrochemical impedance spectroscopy (EIS) to in-situ find parameters useful for the real-time diagnosis. EIS analyses are performed by complex nonlinear least squares (CNLS) curve fitting to measured impedance spectra with an equivalent electric circuit model consisting of several resistances and capacitances attributed to the anode and cathode processes as well as Ohmic resistance of the cell. The characteristic changes of those circuit parameters by internal reforming and anode degradation are extracted, showing that they can be used for the real-time diagnosis of operating SOFCs.
Validation and Verification of Operational Land Analysis Activities at the Air Force Weather Agency
NASA Technical Reports Server (NTRS)
Shaw, Michael; Kumar, Sujay V.; Peters-Lidard, Christa D.; Cetola, Jeffrey
2012-01-01
The NASA developed Land Information System (LIS) is the Air Force Weather Agency's (AFWA) operational Land Data Assimilation System (LDAS) combining real time precipitation observations and analyses, global forecast model data, vegetation, terrain, and soil parameters with the community Noah land surface model, along with other hydrology module options, to generate profile analyses of global soil moisture, soil temperature, and other important land surface characteristics. (1) A range of satellite data products and surface observations used to generate the land analysis products (2) Global, 1/4 deg spatial resolution (3) Model analysis generated at 3 hours. AFWA recognizes the importance of operational benchmarking and uncertainty characterization for land surface modeling and is developing standard methods, software, and metrics to verify and/or validate LIS output products. To facilitate this and other needs for land analysis activities at AFWA, the Model Evaluation Toolkit (MET) -- a joint product of the National Center for Atmospheric Research Developmental Testbed Center (NCAR DTC), AFWA, and the user community -- and the Land surface Verification Toolkit (LVT), developed at the Goddard Space Flight Center (GSFC), have been adapted to operational benchmarking needs of AFWA's land characterization activities.
Analysis of S Characteristics and Pressure Pulsations in a Pump-Turbine With Misaligned Guide Vanes.
Sun, Hui; Xiao, Ruofu; Liu, Weichao; Wang, Fujun
2013-05-01
Growing environmental concerns and the need for better power balancing and frequency control have increased attention in renewable energy sources such as the reversible pump-turbine which can provide both power generation and energy storage. Pump-turbine operation along the S-shaped curve can lead to difficulties in loading the rejection process with unusual increases in water pressure, which lead to machine vibrations. Pressure fluctuations are the primary reason for unstable operation of pump-turbines. Misaligned guide vanes (MGVs) are widely used to control the stability in the S region. There have been experimental investigations and computational fluid dynamics (CFD) simulations of scale models with aligned guide vanes and MGVs with spectral analyses of the S curve characteristics and the pressure pulsations in the frequency and time-frequency domains at runaway conditions. The course of the S characteristic is related to the centrifugal force and the large incident angle at low flow conditions with large vortices forming between the guide vanes and the blade inlets and strong flow recirculation inside the vaneless space as the main factors that lead to the S-shaped characteristics. Preopening some of the guide vanes enables the pump-turbine to avoid the influence of the S characteristic. However, the increase of the flow during runaway destroys the flow symmetry in the runner leading to all asymmetry forces on the runner that leads to hydraulic system oscillations. The MGV technique also increases the pressure fluctuations in the draft tube and has a negative impact on stable operation of the unit.
2017-06-07
a 9- week physical training program, tests of physical endurance and strength , body composition analyses, biomarker collections, and cognitive tests...BDNF results to improving training , a new laboratory capability within RHCP was needed, coupled with an initial operational pilot test of that...traditional AF fitness training and that the improvements in cognitive performance would be correlated with changes in BDNF levels. Specifically, the
NASA Technical Reports Server (NTRS)
1972-01-01
The modular space station comprising small, shuttle-launched modules, and characterized by low initial cost and incremental manning, is described. The initial space station is designed to be delivered into orbit by three space shuttles and assembled in space. The three sections are the power/subsystems module, the crew/operations module, and the general purpose laboratory module. It provides for a crew of six. Subsequently duplicate/crew/operations and power/subsystems modules will be mated to the original modules, and provide for an additional six crewmen. A total of 17 research and applications modules is planned, three of which will be free-flying modules. Details are given on the program plan, modular characteristics, logistics, experiment support capability and requirements, operations analysis, design support analyses, and shuttle interfaces.
Health regionalization in Amazonas: progress and challenges.
Garnelo, Luiza; Sousa, Amandia Braga Lima; Silva, Clayton de Oliveira da
2017-04-01
This paper analyses the health services regionalization process in the State of Amazonas through a case study covering the health sub-region Manaus Surroundings. This is a qualitative, descriptive and analytical research, which data were collected using interviews, documents and Internet reviews, oriented by the guiding concept of health regionalization. Study findings revealed a social setting dominated by asymmetry, verticality, competitiveness and fragile multilateral relations among municipalities, associated to a bureaucratic profile of local institutions operating in the region under study. The political agents have limited acknowledgement of the sociopolitical and institutional conditions in which they operate. They usually impute healthcare networks' management and operational issues to the natural and geographical characteristics of the Amazon region, but their financing, governance and technical capacity are insufficient to overcome them.
NASA Technical Reports Server (NTRS)
1976-01-01
A variable pitch fan actuation system was designed which incorporates a remote nacelle-mounted blade angle regulator. The regulator drives a rotating fan-mounted mechanical actuator through a flexible shaft and differential gear train. The actuator incorporates a high ratio harmonic drive attached to a multitrack spherical cam which changes blade pitch through individual cam follower arms attached to each blade trunnion. Detail design parameters of the actuation system are presented. These include the following: design philosophies, operating limits, mechanical, hydraulic and thermal characteristics, mechanical efficiencies, materials, weights, lubrication, stress analyses, reliability and failure analyses.
Aerodynamic analysis of Pegasus - Computations vs reality
NASA Technical Reports Server (NTRS)
Mendenhall, Michael R.; Lesieutre, Daniel J.; Whittaker, C. H.; Curry, Robert E.; Moulton, Bryan
1993-01-01
Pegasus, a three-stage, air-launched, winged space booster was developed to provide fast and efficient commercial launch services for small satellites. The aerodynamic design and analysis of Pegasus was conducted without benefit of wind tunnel tests using only computational aerodynamic and fluid dynamic methods. Flight test data from the first two operational flights of Pegasus are now available, and they provide an opportunity to validate the accuracy of the predicted pre-flight aerodynamic characteristics. Comparisons of measured and predicted flight characteristics are presented and discussed. Results show that the computational methods provide reasonable aerodynamic design information with acceptable margins. Post-flight analyses illustrate certain areas in which improvements are desired.
Vroomen, P; de Krom, M C T F M; Wilmink, J; Kester, A; Knottnerus, J
2002-01-01
Objective: To evaluate patient characteristics, symptoms, and examination findings in the clinical diagnosis of lumbosacral nerve root compression causing sciatica. Methods: The study involved 274 patients with pain radiating into the leg. All had a standardised clinical assessment and magnetic resonance (MR) imaging. The associations between patient characteristics, clinical findings, and lumbosacral nerve root compression on MR imaging were analysed. Results: Nerve root compression was associated with three patient characteristics, three symptoms, and four physical examination findings (paresis, absence of tendon reflexes, a positive straight leg raising test, and increased finger-floor distance). Multivariate analysis, analysing the independent diagnostic value of the tests, showed that nerve root compression was predicted by two patient characteristics, four symptoms, and two signs (increased finger-floor distance and paresis). The straight leg raise test was not predictive. The area under the curve of the receiver-operating characteristic was 0.80 for the history items. It increased to 0.83 when the physical examination items were added. Conclusions: Various clinical findings were found to be associated with nerve root compression on MR imaging. While this set of findings agrees well with those commonly used in daily practice, the tests tended to have lower sensitivity and specificity than previously reported. Stepwise multivariate analysis showed that most of the diagnostic information revealed by physical examination findings had already been revealed by the history items. PMID:11971050
An Interactive Logistics Centre Information Integration System Using Virtual Reality
NASA Astrophysics Data System (ADS)
Hong, S.; Mao, B.
2018-04-01
The logistics industry plays a very important role in the operation of modern cities. Meanwhile, the development of logistics industry has derived various problems that are urgent to be solved, such as the safety of logistics products. This paper combines the study of logistics industry traceability and logistics centre environment safety supervision with virtual reality technology, creates an interactive logistics centre information integration system. The proposed system utilizes the immerse characteristic of virtual reality, to simulate the real logistics centre scene distinctly, which can make operation staff conduct safety supervision training at any time without regional restrictions. On the one hand, a large number of sensor data can be used to simulate a variety of disaster emergency situations. On the other hand, collecting personnel operation data, to analyse the improper operation, which can improve the training efficiency greatly.
NASA Astrophysics Data System (ADS)
Trifonenkov, A. V.; Trifonenkov, V. P.
2017-01-01
This article deals with a feature of problems of calculating time-average characteristics of nuclear reactor optimal control sets. The operation of a nuclear reactor during threatened period is considered. The optimal control search problem is analysed. The xenon poisoning causes limitations on the variety of statements of the problem of calculating time-average characteristics of a set of optimal reactor power off controls. The level of xenon poisoning is limited. There is a problem of choosing an appropriate segment of the time axis to ensure that optimal control problem is consistent. Two procedures of estimation of the duration of this segment are considered. Two estimations as functions of the xenon limitation were plot. Boundaries of the interval of averaging are defined more precisely.
Persistent hemifacial spasm after microvascular decompression: a risk assessment model.
Shah, Aalap; Horowitz, Michael
2017-06-01
Microvascular decompression (MVD) for hemifacial spasm (HFS) provides resolution of disabling symptoms such as eyelid twitching and muscle contractions of the entire hemiface. The primary aim of this study was to evaluate the predictive value of patient demographics and spasm characteristics on long-term outcomes, with or without intraoperative lateral spread response (LSR) as an additional variable in a risk assessment model. A retrospective study was undertaken to evaluate the associations of pre-operative patient characteristics, as well as intraoperative LSR and need for a staged procedure on the presence of persistent or recurrent HFS at the time of hospital discharge and at follow-up. A risk assessment model was constructed with the inclusion of six clinically or statistically significant variables from the univariate analyses. A receiving operator characteristic curve was generated, and area under the curve was calculated to determine the strength of the predictive model. A risk assessment model was first created consisting of significant pre-operative variables (Model 1) (age >50, female gender, history of botulinum toxin use, platysma muscle involvement). This model demonstrated borderline predictive value for persistent spasm at discharge (AUC .60; p=.045) and fair predictive value at follow-up (AUC .75; p=.001). Intraoperative variables (e.g. LSR persistence) demonstrated little additive value (Model 2) (AUC .67). Patients with a higher risk score (three or greater) demonstrated greater odds of persistent HFS at the time of discharge (OR 1.5 [95%CI 1.16-1.97]; p=.035), as well as greater odds of persistent or recurrent spasm at the time of follow-up (OR 3.0 [95%CI 1.52-5.95]; p=.002) Conclusions: A risk assessment model consisting of pre-operative clinical characteristics is useful in prognosticating HFS persistence at follow-up.
NASA Astrophysics Data System (ADS)
Kohli, Akshay; Robinson, John W.; Ryan, John; McEntee, Mark F.; Brennan, Patrick C.
2011-03-01
The purpose of this study is to explore whether reader characteristics are linked to heightened levels of diagnostic performance in chest radiology using receiver operating characteristic (ROC) and jackknife free response ROC (JAFROC) methodologies. A set of 40 postero-anterior chest radiographs was developed, of which 20 were abnormal containing one or more simulated nodules, of varying subtlety. Images were independently reviewed by 12 boardcertified radiologists including six chest specialists. The observer performance was measured in terms of ROC and JAFROC scores. For the ROC analysis, readers were asked to rate their degree of suspicion for the presence of nodules by using a confidence rating scale (1-6). JAFROC analysis required the readers to locate and rate as many suspicious areas as they wished using the same scale and resultant data were used to generate Az and FOM scores for ROC and JAFROC analyses respectively. Using Pearson methods, scores of performance were correlated with 7 reader characteristics recorded using a questionnaire. JAFROC analysis showed that improved reader performance was significantly (p<=0.05) linked with chest specialty (p<0.03), hours per week reading chest radiographs (p<0.03) and chest readings per year (p<0.04). ROC analyses demonstrated only one significant relationship, hours per week reading chest radiographs (p<0.02).The results of this study have shown that radiologist's performance in the detection of pulmonary nodules on radiographs is significantly linked to chest specialty, hours reading per week and number of radiographs read per year. Also, JAFROC is a more powerful predictor of performance as compared to ROC.
Particulate Hot Gas Stream Cleanup Technical Issues: Quarterly report, July 1-September 30, 1996
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pontius, D.H.
1996-12-09
This is the eighth in a series of quarterly reports describing the activities performed under Contract No. DE-AC21-94MC31160. Analyses of Hot Gas Stream Cleanup (HGCU) ashes and descriptions of filter performance address aspects of filter operation that are apparently linked to the characteristics of the collected ash or the performance of the ceramic barrier filter elements. Task 1 is designed to generate a data base of the key characteristics of ashes collected from operating advanced particle filters (APFS) and to relate these ash properties to the operation and performance of these filters. Task 2 concerns testing and failure analysis ofmore » ceramic filter elements. Under Task I during the past quarter, additional analyses were performed on ashes from the Ahlstrom 10 MWt Pressurized Fluidized Circulating Fluid Bed (PCFB) facility located at Karhula, Finland. Work continued on the HGCU data base being constructed in Microsoft Access. A variety of information has been entered into the data base, including numerical values, short or long text entries, and photographs. Detailed design of a bench top device for high temperature measurement of ash permeability has also begun. In addition to these activities, a paper was prepared and a poster was presented summarizing recent work performed under this contract at the 1996 DOE/METC Contractor`s Conference. A presentation was also given corresponding to the manuscript entitled Particle Characteristics and High-Temperature Filtration that was prepared for publication in the Proceedings of the Thirteenth Annual International Pittsburgh Coal Conference held this September in Pittsburgh, PA. Arrangements have been made to be present at the DOE/METC Modular Gas Cleanup Rig (MGCR) at the conclusion of the next run of the DOE/METC air blown Fluid Bed Gasifier (FBG). This visit will include on-site sampling to collect and characterize the filter cakes collected during FGB operation. Task 2 efforts during the past quarter focused on hoop tensile testing of Schumacher FT20 and Refractron 326 candle filter elements removed from the Karhula APF after 540 hours of service.« less
Zhang, Ruiyun; Wu, Guangyu; Huang, Jiwei; Shi, Oumin; Kong, Wen; Chen, Yonghui; Xu, Jianrong; Xue, Wei; Zhang, Jin; Huang, Yiran
2017-06-06
The present study aimed to assess the impact of peritumoral artery characteristics on renal function outcome prediction using a novel Peritumoral Artery Scoring System based on computed tomography arteriography. Peritumoral artery characteristics and renal function were evaluated in 220 patients who underwent laparoscopic partial nephrectomy and then validate in 51 patients with split and total glomerular filtration rate (GFR). In particular, peritumoral artery classification and diameter were measured to assign arteries into low, moderate, and high Peritumoral Artery Scoring System risk categories. Univariable and multivariable logistic regression analyses were then used to determine risk factors for major renal functional decline. The Peritumoral Artery Scoring System and four other nephrometry systems were compared using receiver operating characteristic curve analysis. The Peritumoral Artery Scoring System was significantly superior to the other systems for predicting postoperative renal function decline (p < 0.001). In receiver operating characteristic analysis, our category system was a superior independent predictor of estimated glomerular filtration rate (eGFR) decline (area-under-the-curve = 0.865, p < 0.001) and total GFR decline (area-under-the-curve = 0.796, p < 0.001), and split GFR decline (area-under-the-curve = 0.841, p < 0.001). Peritumoral artery characteristics were independent predictors of renal function outcome after laparoscopic partial nephrectomy.
A review of hospital characteristics associated with improved performance.
Brand, Caroline A; Barker, Anna L; Morello, Renata T; Vitale, Michael R; Evans, Sue M; Scott, Ian A; Stoelwinder, Johannes U; Cameron, Peter A
2012-10-01
The objective of this review was to critically appraise the literature relating to associations between high-level structural and operational hospital characteristics and improved performance. The Cochrane Library, MEDLINE (Ovid), CINAHL, proQuest and PsychINFO were searched for articles published between January 1996 and May 2010. Reference lists of included articles were reviewed and key journals were hand searched for relevant articles. and data extraction Studies were included if they were systematic reviews or meta-analyses, randomized controlled trials, controlled before and after studies or observational studies (cohort and cross-sectional) that were multicentre, comparative performance studies. Two reviewers independently extracted data, assigned grades of evidence according to the Australian National Health and Medical Research Council guidelines and critically appraised the included articles. Data synthesis Fifty-seven studies were reported within 12 systematic reviews and 47 observational articles. There was heterogeneity in use and definition of performance outcomes. Hospital characteristics investigated were environment (incentives, market characteristics), structure (network membership, ownership, teaching status, geographical setting, service size) and operational design (innovativeness, leadership, organizational culture, public reporting and patient safety practices, information technology systems and decision support, service activity and planning, workforce design, staff training and education). The strongest evidence for an association with overall performance was identified for computerized physician order entry systems. Some evidence supported the associations with workforce design, use of financial incentives, nursing leadership and hospital volume. There is limited, mainly low-quality evidence, supporting the associations between hospital characteristics and healthcare performance. Further characteristic-specific systematic reviews are indicated.
Harmonic analyses of stream temperatures in the Upper Colorado River Basin
Steele, T.D.
1985-01-01
Harmonic analyses were made for available daily water-temperature records for 36 measurement sites on major streams in the Upper Colorado River Basin and for 14 measurement sites on streams in the Piceance structural basin. Generally (88 percent of the station years analyzed), more than 80 percent of the annual variability of temperatures of streams in the Upper Colorado River Basin was explained by the simple-harmonic function. Significant trends were determined for 6 of the 26 site records having 8 years or more record. In most cases, these trends resulted from construction and operation of upstream surface-water impoundments occurring during the period of record. Regional analysis of water-temperature characteristics at the 14 streamflow sites in the Piceance structural basin indicated similarities in water-temperature characteristics for a small range of measurement-site elevations. Evaluation of information content of the daily records indicated that less-than-daily measurement intervals should be considered, resulting in substantial savings in measurement and data-processing costs. (USGS)
Brunner, Emanuel; De Herdt, Amber; Minguet, Philippe; Baldew, Se-Sergio; Probst, Michel
2013-01-01
The primary purpose was to detect randomized controlled trials investigating cognitive behaviour therapy-based (CBT) treatments applied in acute/sub-acute low back pain (LBP). The secondary purpose was to analyse the methodological properties of the included studies, and to identify theory-based treatment strategies that are applicable for physiotherapists. A systematic literature search was conducted using four databases. Risk of bias of included studies was assessed and the methodological properties summarized. In addition, content and treatment theory of detected CBT-based strategies were systematically analysed and classified into three distinctive concepts of CBT: operant, cognitive and respondent treatment. Finally, applicability of treatment strategies in physiotherapy practice was discussed. Eight studies were included in the present systematic review. Half of the studies suffered from high risk of bias, and study characteristics varied in all domains of methodology, particularly in terms of treatment design and outcome measures. Graded activity, an operant treatment approach based on principles of operant conditioning, was identified as a CBT-based strategy with traceable theoretical justification that can be applied by physiotherapists. Operant conditioning can be integrated in ambulant physiotherapy practice and is a promising CBT-based strategy for the prevention of chronic LBP.
Numerical simulation of cavitation flow characteristic on Pelton turbine bucket surface
NASA Astrophysics Data System (ADS)
Zeng, C. J.; Xiao, Y. X.; Zhu, W.; Yao, Y. Y.; Wang, Z. W.
2015-01-01
The internal flow in the rotating bucket of Pelton turbine is free water sheet flow with moving boundary. The runner operates under atmospheric and the cavitation in the bucket is still a controversial problem. While more and more field practice proved that there exists cavitation in the Pelton turbine bucket and the cavitation erosion may occur at the worst which will damage the bucket. So a well prediction about the cavitation flow on the bucket surface of Pelton turbine and the followed cavitation erosion characteristic can effectively guide the optimization of Pelton runner bucket and the stable operation of unit. This paper will investigate the appropriate numerical model and method for the unsteady 3D water-air-vapour multiphase cavitation flow which may occur on the Pelton bucket surface. The computational domain will include the nozzle pipe flow, semi-free surface jet and runner domain. Via comparing the numerical results of different turbulence, cavity and multiphase models, this paper will determine the suitable numerical model and method for the simulation of cavitation on the Pelton bucket surface. In order to investigate the conditions corresponding to the cavitation phenomena on the bucket surface, this paper will adopt the suitable model to simulate the various operational conditions of different water head and needle travel. Then, the characteristics of cavitation flow the development process of cavitation will be analysed in in great detail.
Bearing tester data compilation, analysis, and reporting and bearing math modeling
NASA Technical Reports Server (NTRS)
1986-01-01
A test condition data base was developed for the Bearing and Seal Materials Tester (BSMT) program which permits rapid retrieval of test data for trend analysis and evaluation. A model was developed for the Space shuttle Main Engine (SSME) Liquid Oxygen (LOX) turbopump shaft/bearing system. The model was used to perform parametric analyses to determine the sensitivity of bearing operating characteristics and temperatures to variations in: axial preload, contact friction, coolant flow and subcooling, heat transfer coefficients, outer race misalignments, and outer race to isolator clearances. The bearing program ADORE (Advanced Dynamics of Rolling Elements) was installed on the UNIVAC 1100/80 computer system and is operational. ADORE is an advanced FORTRAN computer program for the real time simulation of the dynamic performance of rolling bearings. A model of the 57 mm turbine-end bearing is currently being checked out. Analyses were conducted to estimate flow work energy for several flow diverter configurations and coolant flow rates for the LOX BSMT.
Odor intensity and characterization of jet exhaust and chemical analytical measurements
NASA Technical Reports Server (NTRS)
Kendall, D. A.; Levins, P. L.
1973-01-01
Odor and chemical analyses were carried out on the exhaust samples from a J-57 combustor can operated over a range of inlet conditions, and with several fuel types and nozzle modifications. The odor characteristics and total intensity of odor for each exhaust were determined over a range of dilutions to allow for a least squares determination of the intensity at 1,000 to 1 dilutions. Analytical measures included the concentration of total hydrocarbons and the concentrations of aromatic organic species and oxygenated organic species from collected samples which were taken concurrently. A correlation was found between the concentration of the odorous oxygenated fraction and the total intensity of aroma. Inlet operating conditions and nozzle modifications which increase the efficiency of combustion as measured by exhaust gas analyses reduce the odor intensity and the quantity of oxygenates in the exhaust. The type of fuel burned altered the intensity of odor in relation to the quantity of oxygenates produced and, in some instances, changed the odor character.
Robba, Chiara; Bragazzi, Nicola Luigi; Bertuccio, Alessandro; Cardim, Danilo; Donnelly, Joseph; Sekhon, Mypinder; Lavinio, Andrea; Duane, Derek; Burnstein, Rowan; Matta, Basil; Bacigaluppi, Susanna; Lattuada, Marco; Czosnyka, Marek
2017-07-01
Prone positioning and positive end-expiratory pressure can improve pulmonary gas exchange and respiratory mechanics. However, they may be associated with the development of intracranial hypertension. Intracranial pressure (ICP) can be noninvasively estimated from the sonographic measurement of the optic nerve sheath diameter (ONSD) and from the transcranial Doppler analysis of the pulsatility (ICPPI) and the diastolic component (ICPFVd) of the velocity waveform. The effect of the prone positioning and positive end-expiratory pressure on ONSD, ICPFVd, and ICPPI was assessed in a prospective study of 30 patients undergoing spine surgery. One-way repeated measures analysis of variance, fixed-effect multivariate regression models, and receiver operating characteristic analyses were used to analyze numerical data. The mean values of ONSD, ICPFVd, and ICPPI significantly increased after change from supine to prone position. Receiver operating characteristic analyses demonstrated that, among the noninvasive methods, the mean ONSD measure had the greatest area under the curve signifying it is the most effective in distinguishing a hypothetical change in ICP between supine and prone positioning (0.86±0.034 [0.79 to 0.92]). A cutoff of 0.43 cm was found to be a best separator of ONSD value between supine and prone with a specificity of 75.0 and a sensitivity of 86.7. Noninvasive ICP estimation may be useful in patients at risk of developing intracranial hypertension who require prone positioning.
NASA Astrophysics Data System (ADS)
Yousefvand, H. R.
2017-12-01
We report a study of the effects of hot-electron and hot-phonon dynamics on the output characteristics of quantum cascade lasers (QCLs) using an equivalent circuit-level model. The model is developed from the energy balance equation to adopt the electron temperature in the active region levels, the heat transfer equation to include the lattice temperature, the nonequilibrium phonon rate to account for the hot phonon dynamics and simplified two-level rate equations to incorporate the carrier and photon dynamics in the active region. This technique simplifies the description of the electron-phonon interaction in QCLs far from the equilibrium condition. Using the presented model, the steady and transient responses of the QCLs for a wide range of sink temperatures (80 to 320 K) are investigated and analysed. The model enables us to explain the operating characteristics found in QCLs. This predictive model is expected to be applicable to all QCL material systems operating in pulsed and cw regimes.
Rosman, Noor Hasyimah; Nor Anuar, Aznah; Chelliapan, Shreeshivadasan; Md Din, Mohd Fadhil; Ujang, Zaini
2014-06-01
The influence of hydraulic retention time (HRT, 24, 12, and 6h) on the physical characteristics of granules and performance of a sequencing batch reactor (SBR) treating rubber wastewater was investigated. Results showed larger granular sludge formation at HRT of 6h with a mean size of 2.0±0.1mm, sludge volume index of 20.1mLg(-1), settling velocity of 61mh(-1), density of 78.2gL(-1) and integrity coefficient of 9.54. Scanning electron microscope analyses revealed different morphology of microorganisms and structural features of granules when operated at various HRT. The results also demonstrated that up to 98.4% COD reduction was achieved when the reactor was operated at low HRT (6h). Around 92.7% and 89.5% removal efficiency was noted for ammonia and total nitrogen in the granular SBR system during the treatment of rubber wastewater. Copyright © 2014 Elsevier Ltd. All rights reserved.
Islam, Mohammad Tariqul; Alam, Md. Shahidul
2013-01-01
A compact planar meander-bridge high impedance electromagnetic structure (MBHIES) was designed and its bandgap characteristics, mutual coupling reduction abilities were studied and compared in detail. Several parametric analyses were performed to obtain optimized design values and the transmission responses were calculated through the suspended microstrip line and waveguide simulation methods. The achieved bandgap is 2.3 GHz (2.55–4.85 GHz) with −61 dB minimum transmission coefficient level at the center frequency of 3.6 GHz. To see the effectiveness, the proposed design was inserted between a microstrip patch antenna array which operates at 3.8 GHz and whose operating bandwidth falls within the MBHIES bandgap. The surface wave suppression phenomenon was analyzed and simulated results are verified by measuring the fabricated prototypes, both are in good agreement. The configuration reduced the mutual coupling by 20.69 dB in simulation and 19.18 dB in measurement, without affecting the radiation characteristics of the array but increasing the gain slightly. PMID:28809299
Islam, Mohammad Tariqul; Alam, Md Shahidul
2013-01-07
A compact planar meander-bridge high impedance electromagnetic structure (MBHIES) was designed and its bandgap characteristics, mutual coupling reduction abilities were studied and compared in detail. Several parametric analyses were performed to obtain optimized design values and the transmission responses were calculated through the suspended microstrip line and waveguide simulation methods. The achieved bandgap is 2.3 GHz (2.55-4.85 GHz) with -61 dB minimum transmission coefficient level at the center frequency of 3.6 GHz. To see the effectiveness, the proposed design was inserted between a microstrip patch antenna array which operates at 3.8 GHz and whose operating bandwidth falls within the MBHIES bandgap. The surface wave suppression phenomenon was analyzed and simulated results are verified by measuring the fabricated prototypes, both are in good agreement. The configuration reduced the mutual coupling by 20.69 dB in simulation and 19.18 dB in measurement, without affecting the radiation characteristics of the array but increasing the gain slightly.
Preliminary noise tradeoff study of a Mach 2.7 cruise aircraft
NASA Technical Reports Server (NTRS)
Mascitti, V. R.; Maglieri, D. J. (Editor); Raney, J. P. (Editor)
1979-01-01
NASA computer codes in the areas of preliminary sizing and enroute performance, takeoff and landing performance, aircraft noise prediction, and economics were used in a preliminary noise tradeoff study for a Mach 2.7 design supersonic cruise concept. Aerodynamic configuration data were based on wind-tunnel model tests and related analyses. Aircraft structural characteristics and weight were based on advanced structural design methodologies, assuming conventional titanium technology. The most advanced noise prediction techniques available were used, and aircraft operating costs were estimated using accepted industry methods. The 4-engines cycles included in the study were based on assumed 1985 technology levels. Propulsion data was provided by aircraft manufacturers. Additional empirical data is needed to define both noise reduction features and other operating characteristics of all engine cycles under study. Data on VCE design parameters, coannular nozzle inverted flow noise reduction and advanced mechanical suppressors are urgently needed to reduce the present uncertainties in studies of this type.
Itoh, Shinji; Uchiyama, Hideaki; Kawanaka, Hirofumi; Higashi, Takahiro; Egashira, Akinori; Eguchi, Daihiko; Okuyama, Toshiro; Tateishi, Masahiro; Korenaga, Daisuke; Takenaka, Kenji
2014-02-01
There seemed to be characteristic risk factors in cirrhotic patients for posthepatectomy complications because these patients have less hepatic reserve as compared with noncirrhotic patients. The aim of the current study was to identify these characteristic risk factors in cirrhotic patients. We performed 419 primary hepatectomies for hepatocellular carcinoma. The patients were divided into the cirrhotic group (n = 198) and the noncirrhotic group (n = 221), and the risk factors for posthepatectomy complications were compared between the groups. Thirty-six cirrhotic patients (18.2%) experienced Clavien's Grade III or more complications. Tumor size, intraoperative blood loss, duration of operation, major hepatectomy (two or more segments), and necessity of blood transfusion were found to be significant risk factors in univariate analyses. Multivariate analysis revealed that major hepatectomy and intraoperative blood loss were independent risk factors for posthepatectomy complications in patients with cirrhosis. On the other hand, the duration of operation was only an independent risk factor for posthepatectomy complication in noncirrhotic patients. Cirrhotic patients should avoid a major hepatectomy and undergo a limited resection preserving as much liver tissue as possible and meticulous surgical procedures to lessen intraoperative blood loss are mandatory to prevent major posthepatectomy complications.
Solar power satellite system definition study. Volume 3: Operations and systems synthesis, phase 2
NASA Technical Reports Server (NTRS)
1979-01-01
The results of the operations analyses are reported. Some of these analyses examined operations aspects of space vehicle in-space maintenance. Many of the analyses explored in great depth operations concerned the LEO Base cargo handling operations. Personnel transportation operations and cargo packaging were also analyzed. These operations analyses were performed to define the operational requirements for all of the SPS system elements so that equipment and facilities could be synthesized, and to make estimates of the manpower requirements. An overall, integrated, end-to-end description of the SPS operations is presented. The detailed operations analyses, upon which this integrated description was based, are included.
Cohen, Lisa J; Tanis, Thachell; Ardalan, Firouz; Yaseen, Zimri; Galynker, Igor
2016-08-30
Diagnostic criteria for borderline personality disorder (BPD) and mood and psychotic disorders characterized by major mood episodes (i.e., major depressive, bipolar and schizoaffective disorder) share marked overlap in symptom presentation, complicating differential diagnosis. The current study tests the hypothesis that maladaptive interpersonal schemas (MIS) are characteristic of BPD, but not of the major mood disorders. One hundred psychiatric inpatients were assessed by SCID I, SCID II and the Young Schema Questionnaire (YSQ-S2). Logistic regression analyses tested the association between MIS (measured by the YSQ-S2) and BPD, bipolar, major depressive and schizoaffective disorder. Receiver operator characteristic (ROC) curve analyses assessed the sensitivity and specificity of MIS as a marker of BPD. After covariation for comorbidity with each of the 3 mood disorders, BPD was robustly associated with 4 out of 5 schema domains. In contrast, only one of fifteen regression analyses demonstrated a significant association between any mood disorder and schema domain after covariation for comorbid BPD. ROC analyses of the 5 schema domains suggested Disconnection/Rejection had the greatest power for identification of BPD cases. These data support the specific role of maladaptive interpersonal schemas in BPD and potentially contribute to greater conceptual clarity about the distinction between BPD and the major mood disorders. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Jeguirim, Mejdi; Kraiem, Nesrine; Lajili, Marzouk; Guizani, Chamseddine; Zorpas, Antonis; Leva, Yann; Michelin, Laure; Josien, Ludovic; Limousy, Lionel
2017-04-01
This paper aims to identify the correlation between the mineral contents in agropellets and particle matter and bottom ash characteristics during combustion in domestic boilers. Four agrifood residues with higher mineral contents, namely grape marc (GM), tomato waste (TW), exhausted olive mill solid waste (EOMSW) and olive mill wastewater (OMWW), were selected. Then, seven different pellets were produced from pure residues or their mixture and blending with sawdust. The physico-chemical properties of the produced pellets were analysed using different analytical techniques, and a particular attention was paid to their mineral contents. Combustion tests were performed in 12-kW domestic boiler. The particle matter (PM) emission was characterised through the particle number and mass quantification for different particle size. The bottom ash composition and size distribution were also characterised. Molar balance and chemometric analyses were performed to identify the correlation between the mineral contents and PM and bottom ash characteristics. The performed analyses indicate that K, Na, S and Cl are released partially or completely during combustion tests. In contrast, Ca, Mg, Si, P, Al, Fe and Mn are retained in the bottom ash. The chemometric analyses indicate that, in addition to the operating conditions and the pellet ash contents, K and Si concentrations have a significant effect on the PM emissions as well as on the agglomeration of bottom ash.
NASA Astrophysics Data System (ADS)
Feng, Peilei; Xu, Tianqi; Liu, Xiaoxin; Jan, Lisheng; Dai, Xiaozhong; Cai, Pengcheng
2018-01-01
Nujiang power grid is at the end of the Yunnan power grid, which is the side of power supply. Due to the regional restrictions and the lag of economic development and other factors, the structure of the power grid in Nujiang is relatively weak, and the voltage of the regional power grid is more prominent. Based on analysis on voltage exceeding limits of Nujiang different power grid, combined with the operating characteristics of regional power grid and reactive power compensation measures, this paper proposes measures for adjustment of Nujiang grid voltage, and analyses the result of adjustment of voltage exceeding limits, which can effectively improve the voltage and power quality.
NASA Astrophysics Data System (ADS)
Nix, Michael B.
2005-12-01
Early design decisions in the development of space launch systems determine the costs to acquire and operate launch systems. Some sources indicate that as much as 90% of life cycle costs are fixed by the end of the critical design review phase. System characteristics determined by these early decisions are major factors in the acquisition cost of flight hardware elements and facilities and influence operations costs through the amount of maintenance and support labor required to sustain system function. Operations costs are also dependent on post-development management decisions regarding how much labor will be deployed to meet requirements of market demand and ownership profit. The ability to perform early trade-offs between these costs is vital to the development of systems that have the necessary capacity to provide service and are profitable to operate. An Excel-based prototype model was developed for making early analyses of trade-offs between the costs to operate a space launch system and to acquire the necessary assets to meet a given set of operational requirements. The model, integrating input from existing models and adding missing capability, allows the user to make such trade-offs across a range of operations concepts (required flight rates, staffing levels, shifts per workday, workdays per week and per year, unreliability, wearout and depot maintenance) and the number, type and capability of assets (flight hardware elements, processing and supporting facilities and infrastructure). The costs and capabilities of hypothetical launch systems can be modeled as a function of interrelated turnaround times and labor resource levels, and asset loss and retirement. The number of flight components and facilities required can be calculated and the operations and acquisition costs compared for a specified scenario. Findings, based on the analysis of a hypothetical two stage to orbit, reusable, unmanned launch system, indicate that the model is suitable for the trade-off analyses desired. The minimum turnaround time/maximum labor allocation for specific hardware configurations and characteristics and corresponding asset requirements can be estimated. Either turnaround time or resources can be varied and the resulting operations and acquisition costs can be compared. Asset reliability, wearout and depot maintenance intervals and durations can be varied as well to analyze the effects on costs. Likewise, the effects on operations and acquisitions costs of the introduction of alternative technologies that affect reliability, maintainability and supportability in various hardware configurations can be evaluated.
Turbopump Design and Analysis Approach for Nuclear Thermal Rockets
NASA Technical Reports Server (NTRS)
Chen, Shu-cheng S.; Veres, Joseph P.; Fittje, James E.
2006-01-01
A rocket propulsion system, whether it is a chemical rocket or a nuclear thermal rocket, is fairly complex in detail but rather simple in principle. Among all the interacting parts, three components stand out: they are pumps and turbines (turbopumps), and the thrust chamber. To obtain an understanding of the overall rocket propulsion system characteristics, one starts from analyzing the interactions among these three components. It is therefore of utmost importance to be able to satisfactorily characterize the turbopump, level by level, at all phases of a vehicle design cycle. Here at NASA Glenn Research Center, as the starting phase of a rocket engine design, specifically a Nuclear Thermal Rocket Engine design, we adopted the approach of using a high level system cycle analysis code (NESS) to obtain an initial analysis of the operational characteristics of a turbopump required in the propulsion system. A set of turbopump design codes (PumpDes and TurbDes) were then executed to obtain sizing and performance characteristics of the turbopump that were consistent with the mission requirements. A set of turbopump analyses codes (PUMPA and TURBA) were applied to obtain the full performance map for each of the turbopump components; a two dimensional layout of the turbopump based on these mean line analyses was also generated. Adequacy of the turbopump conceptual design will later be determined by further analyses and evaluation. In this paper, descriptions and discussions of the aforementioned approach are provided and future outlooks are discussed.
Integrated Vehicle Ground Vibration Testing in Support of Launch Vehicle Loads and Controls Analysis
NASA Technical Reports Server (NTRS)
Askins, Bruce R.; Davis, Susan R.; Salyer, Blaine H.; Tuma, Margaret L.
2008-01-01
All structural systems possess a basic set of physical characteristics unique to that system. These unique physical characteristics include items such as mass distribution and damping. When specified, they allow engineers to understand and predict how a structural system behaves under given loading conditions and different methods of control. These physical properties of launch vehicles may be predicted by analysis or measured by certain types of tests. Generally, these properties are predicted by analysis during the design phase of a launch vehicle and then verified by testing before the vehicle becomes operational. A ground vibration test (GVT) is intended to measure by test the fundamental dynamic characteristics of launch vehicles during various phases of flight. During the series of tests, properties such as natural frequencies, mode shapes, and transfer functions are measured directly. These data will then be used to calibrate loads and control systems analysis models for verifying analyses of the launch vehicle. NASA manned launch vehicles have undergone ground vibration testing leading to the development of successful launch vehicles. A GVT was not performed on the inaugural launch of the unmanned Delta III which was lost during launch. Subsequent analyses indicated had a GVT been performed, it would have identified instability issues avoiding loss of the vehicle. This discussion will address GVT planning, set-up, execution and analyses, for the Saturn and Shuttle programs, and will also focus on the current and on-going planning for the Ares I and V Integrated Vehicle Ground Vibration Test (IVGVT).
Hansson, Jonny; Månsson, Lars Gunnar; Båth, Magnus
2016-06-01
The purpose of the present work was to investigate the validity of using single-reader-adapted receiver operating characteristics (ROC) software for analysis of visual grading characteristics (VGC) data. VGC data from four published VGC studies on optimisation of X-ray examinations, previously analysed using ROCFIT, were reanalysed using a recently developed software dedicated to VGC analysis (VGC Analyzer), and the outcomes [the mean and 95 % confidence interval (CI) of the area under the VGC curve (AUCVGC) and the p-value] were compared. The studies included both paired and non-paired data and were reanalysed both for the fixed-reader and the random-reader situations. The results showed good agreement between the softwares for the mean AUCVGC For non-paired data, wider CIs were obtained with VGC Analyzer than previously reported, whereas for paired data, the previously reported CIs were similar or even broader. Similar observations were made for the p-values. The results indicate that the use of single-reader-adapted ROC software such as ROCFIT for analysing non-paired VGC data may lead to an increased risk of committing Type I errors, especially in the random-reader situation. On the other hand, the use of ROC software for analysis of paired VGC data may lead to an increased risk of committing Type II errors, especially in the fixed-reader situation. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Main, Keith L; Soman, Salil; Pestilli, Franco; Furst, Ansgar; Noda, Art; Hernandez, Beatriz; Kong, Jennifer; Cheng, Jauhtai; Fairchild, Jennifer K; Taylor, Joy; Yesavage, Jerome; Wesson Ashford, J; Kraemer, Helena; Adamson, Maheen M
2017-01-01
Standard MRI methods are often inadequate for identifying mild traumatic brain injury (TBI). Advances in diffusion tensor imaging now provide potential biomarkers of TBI among white matter fascicles (tracts). However, it is still unclear which tracts are most pertinent to TBI diagnosis. This study ranked fiber tracts on their ability to discriminate patients with and without TBI. We acquired diffusion tensor imaging data from military veterans admitted to a polytrauma clinic (Overall n = 109; Age: M = 47.2, SD = 11.3; Male: 88%; TBI: 67%). TBI diagnosis was based on self-report and neurological examination. Fiber tractography analysis produced 20 fiber tracts per patient. Each tract yielded four clinically relevant measures (fractional anisotropy, mean diffusivity, radial diffusivity, and axial diffusivity). We applied receiver operating characteristic (ROC) analyses to identify the most diagnostic tract for each measure. The analyses produced an optimal cutpoint for each tract. We then used kappa coefficients to rate the agreement of each cutpoint with the neurologist's diagnosis. The tract with the highest kappa was most diagnostic. As a check on the ROC results, we performed a stepwise logistic regression on each measure using all 20 tracts as predictors. We also bootstrapped the ROC analyses to compute the 95% confidence intervals for sensitivity, specificity, and the highest kappa coefficients. The ROC analyses identified two fiber tracts as most diagnostic of TBI: the left cingulum (LCG) and the left inferior fronto-occipital fasciculus (LIF). Like ROC, logistic regression identified LCG as most predictive for the FA measure but identified the right anterior thalamic tract (RAT) for the MD, RD, and AD measures. These findings are potentially relevant to the development of TBI biomarkers. Our methods also demonstrate how ROC analysis may be used to identify clinically relevant variables in the TBI population.
A Children of Twins Study of parental divorce and offspring psychopathology.
D'Onofrio, Brian M; Turkheimer, Eric; Emery, Robert E; Maes, Hermine H; Silberg, Judy; Eaves, Lindon J
2007-07-01
Although parental divorce is associated with increased substance use and internalizing problems, experiencing the separation of one's parents may not cause these outcomes. The relations may be due to genetic or environmental selection factors, characteristics that lead to both marital separation and offspring functioning. We used the Children of Twins (CoT) Design to explore whether unmeasured genetic or environmental factors related to the twin parent, and measured characteristics of both parents, account for the association between parental divorce and offspring substance use and internalizing problems. The association between parental divorce and offspring substance use problems remained robust when controlling for genetic and environmental risk from the twin parent associated with parental divorce, and measured characteristics of both parents. The results do not prove, but are consistent with, a causal connection. In contrast, the analyses suggest that shared genetic liability in parents and their offspring accounts for the increased risk of internalizing problems in adult offspring from divorced families. The study illustrates that unmeasured genetic and environmental selection factors must be considered when studying parental divorce. In explaining associations between parental divorce and young-adult adjustment, our evidence suggests that selection versus causal mechanisms may operate differently for substance abuse (a causal relation) and internalizing problems (an artifact of selection). The CoT design only controls for the genetic and environmental characteristics of one parent; thus, additional genetically informed analyses are needed.
Defining Chronic Cough: A Systematic Review of the Epidemiological Literature
Song, Woo-Jung; Chang, Yoon-Seok; Faruqi, Shoaib; Kang, Min-Koo; Kim, Ju-Young; Kang, Min-Gyu; Kim, Sujeong; Jo, Eun-Jung; Lee, Seung-Eun; Kim, Min-Hye; Plevkova, Jana; Park, Heung-Woo
2016-01-01
Purpose Recent evidence suggests a global burden of chronic cough in general populations. However, the definitions vary greatly among epidemiological studies, and none have been validated for clinical relevance. We aimed to examine previous epidemiological definitions in detail and explore the operational characteristics. Methods A systematic review was conducted for epidemiological surveys that reported the prevalence of chronic cough in general adult populations during the years 1980 to 2013. A literature search was performed on Pubmed and Embase without language restriction. Epidemiological definitions for chronic cough were classified according to their components, such as cutoff duration. Meta-analyses were performed for the male-to-female ratio of chronic cough prevalence to explore operational characteristics of epidemiological definitions. Results A total of 70 studies were included in the systematic review. The most common epidemiological definition was identified as 'cough ≥3 months' duration without specification of phlegm (n=50); however, it conflicted with the cutoff duration in current clinical guidelines (cough ≥8 weeks). Meta-analyses were performed for the male-to-female ratio of chronic cough among 28 studies that reported sex-specific prevalence using the most common definition. The pooled male-to-female odds ratio was 1.26 (95% confidence interval 0.92-1.73) with significant heterogeneity (I2=96%, P<0.001), which was in contrast to clinical observations of female predominance from specialist clinics. Subgroup analyses did not reverse the ratio or reduce the heterogeneity. Conclusions This study identified major issues in defining chronic cough in future epidemiological studies. The conflict between epidemiological and clinical diagnostic criteria needs to be resolved. The unexpected difference in the gender predominance between the community and clinics warrants further studies. Clinical validation of the existing definition is required. PMID:26739408
Saade, Charbel; Mohamad, May; Kerek, Racha; Hamieh, Nadine; Alsheikh Deeb, Ibrahim; El-Achkar, Bassam; Tamim, Hani; Abdul Razzak, Farah; Haddad, Maurice; Abi-Ghanem, Alain S; El-Merhi, Fadi
The aim of this article was to investigate the opacification of the renal vasculature and the urogenital system during computed tomography urography by using a quadruple-phase contrast media in a triphasic scan protocol. A total of 200 patients with possible urinary tract abnormalities were equally divided between 2 protocols. Protocol A used the conventional single bolus and quadruple-phase scan protocol (pre, arterial, venous, and delayed), retrospectively. Protocol B included a quadruple-phase contrast media injection with a triphasic scan protocol (pre, arterial and combined venous, and delayed), prospectively. Each protocol used 100 mL contrast and saline at a flow rate of 4.5 mL. Attenuation profiles and contrast-to-noise ratio of the renal arteries, veins, and urogenital tract were measured. Effective radiation dose calculation, data analysis by independent sample t test, receiver operating characteristic, and visual grading characteristic analyses were performed. In arterial circulation, only the inferior interlobular arteries in both protocols showed a statistical significance (P < 0.05). Venously, the inferior vena cava, proximal and distal renal veins demonstrated a significant opacification reduction in protocol B than in protocol A (P < 0.001). Protocol B showed a significantly higher mean contrast-to-noise ratio than protocol A (protocol B: 22.68 ± 13.72; protocol A: 14.75 ± 5.76; P < 0.001). Radiation dose was significantly reduced in protocol B (7.38 ± 2.22 mSv) than in protocol A (12.28 ± 2.72 mSv) (P < 0.001). Visual grading characteristic (P < 0.027) and receiver operating characteristic (P < 0.0001) analyses demonstrated a significant preference for protocol B. In computed tomography urography, augmented quadruple-phase contrast media and triphasic scan protocol usage increases the image quality at a reduced radiation dose.
Xu, Bin; Lin, Yongsheng; Wang, Zhihong; Cao, Junming; Yang, Yipeng; Xia, Hehuan; Zhang, Yingze
2017-07-01
An increasing number of meta-analyses comparing intramedullary fixation (IF) with plate fixation (PF) for displaced midshaft clavicle fracture have been reported, but the inconsistent results obtained might confuse decision-making. We systematically reviewed discordant meta-analyses for assisting the decision-maker in interpreting and selecting amongst discordant meta-analyses and providing surgical recommendations for displaced midshaft clavicle fracture according to currently best available evidence. Meta-analyses on IF and PF for displaced midshaft clavicle fracture were identified by searching PubMed, Emabase and the Cochrane Library. A review of meta-analysis quality and data extraction was individually conducted by two reviewers. The meta-analysis providing the best available evidence was identified using the Jadad decision algorithm. Nine studies were included, five of which were of Level-II evidence and four of which were of Level-III evidence. These meta-analyses scored from 6 to 10 according to the Assessment of Multiple Systematic Reviews instrument. With respect to the Jadad decision algorithm, the best meta-analysis was chosen depending upon publication characteristics and methodology of primary studies, language restrictions, and whether data on individual patients were analysed. A meta-analysis incorporating more randomised controlled trials was eventually selected. The best available evidence indicated that the differences between IF and PF were not significant in terms of shoulder function or the rate of treatment failure. However, IF significantly decreased the operative time and the rate of non-operative complications, especially the rate of infection. Based on the best available evidence, IF may be superior to PF for treating displaced midshaft clavicle fracture. Copyright © 2017. Published by Elsevier Ltd.
Valdes, Pablo A.; Bekelis, Kimon; Harris, Brent T.; Wilson, Brian C.; Leblond, Frederic; Kim, Anthony; Simmons, Nathan E.; Erkmen, Kadir; Paulsen, Keith D.; Roberts, David W.
2014-01-01
BACKGROUND The use of 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence has shown promise as a surgical adjunct for maximizing the extent of surgical resection in gliomas. To date, the clinical utility of 5-ALA in meningiomas is not fully understood, with most descriptive studies using qualitative approaches to 5-ALA-PpIX. OBJECTIVE To assess the diagnostic performance of 5-ALA-PpIX fluorescence during surgical resection of meningioma. METHODS ALA was administered to 15 patients with meningioma undergoing PpIX fluorescence-guided surgery at our institution. At various points during the procedure, the surgeon performed qualitative, visual assessments of fluorescence by using the surgical microscope, followed by a quantitative fluorescence measurement by using an intra-operative probe. Specimens were collected at each point for subsequent neuropathological analysis. Clustered data analysis of variance was used to ascertain a difference between groups, and receiver operating characteristic analyses were performed to assess diagnostic capabilities. RESULTS Red-pink fluorescence was observed in 80% (12/15) of patients, with visible fluorescence generally demonstrating a strong, homogenous character. Quantitative fluorescence measured diagnostically significant PpIX concentrations (CPpIx) in both visibly and nonvisibly fluorescent tissues, with significantly higher CPpIx in both visibly fluorescent (P < .001) and tumor tissue (P = .002). Receiver operating characteristic analyses also showed diagnostic accuracies up to 90% for differentiating tumor from normal dura. CONCLUSION ALA-induced PpIX fluorescence guidance is a potential and promising adjunct in accurately detecting neoplastic tissue during meningioma resective surgery. These results suggest a broader reach for PpIX as a biomarker for meningiomas than was previously noted in the literature. PMID:23887194
Study on static and dynamic characteristics of moving magnet linear compressors
NASA Astrophysics Data System (ADS)
Chen, N.; Tang, Y. J.; Wu, Y. N.; Chen, X.; Xu, L.
2007-09-01
With the development of high-strength NdFeB magnetic material, moving magnet linear compressors have been gradually introduced in the fields of refrigeration and cryogenic engineering, especially in Stirling and pulse tube cryocoolers. This paper presents simulation and experimental investigations on the static and dynamic characteristics of a moving magnet linear motor and a moving magnet linear compressor. Both equivalent magnetic circuits and finite element approaches have been used to model the moving magnet linear motor. Subsequently, the force and equilibrium characteristics of the linear motor have been predicted and verified by detailed static experimental analyses. In combination with a harmonic analysis, experimental investigations were conducted on a prototype of a moving magnet linear compressor. A voltage-stroke relationship, the effect of charging pressure on the performance and dynamic frequency response characteristics are investigated. Finally, the method to identify optimal points of the linear compressor has been described, which is indispensable to the design and operation of moving magnet linear compressors.
Systems analysis of urban wastewater systems--two systematic approaches to analyse a complex system.
Benedetti, L; Blumensaat, F; Bönisch, G; Dirckx, G; Jardin, N; Krebs, P; Vanrolleghem, P A
2005-01-01
This work was aimed at performing an analysis of the integrated urban wastewater system (catchment area, sewer, WWTP, receiving water). It focused on analysing the substance fluxes going through the system to identify critical pathways of pollution, as well as assessing the effectiveness of energy consumption and operational/capital costs. Two different approaches were adopted in the study to analyse urban wastewater systems of diverse characteristics. In the first approach a wide ranged analysis of a system at river basin scale is applied. The Nete river basin in Belgium, a tributary of the Schelde, was analysed through the 29 sewer catchments constituting the basin. In the second approach a more detailed methodology was developed to separately analyse two urban wastewater systems situated within the Ruhr basin (Germany) on a river stretch scale. The paper mainly focuses on the description of the method applied. Only the most important results are presented. The main outcomes of these studies are: the identification of stressors on the receiving water bodies, an extensive benchmarking of wastewater systems, and the evidence of the scale dependency of results in such studies.
Rados, Edita; Pittenauer, Ernst; Frank, Johannes; Varmuza, Kurt; Allmaier, Günter
2018-04-30
We have developed a target system which enables the use of only one target (i.e. target preparation set) for three different laser desorption ionization (LDI)/matrix-assisted laser desorption ionization (MALDI) mass spectrometric instruments. The focus was on analysing small biomolecules with LDI for future use of the system for the study of meteorite samples (carbonaceous chondrites) using devices with different mass spectrometric performance characteristics. Three compounds were selected due to their potential presence in meteoritic chondrites: tryptophan, 2-deoxy-d-ribose and triphenylene. They were prepared (with and without MALDI matrix, i.e. MALDI and LDI) and analysed with three different mass spectrometers (LinTOF/curved field RTOF, LinTOF/RTOF and QqRTOF). The ion sources of two of the instruments were run at high vacuum, and one at intermediate pressure. Two devices used a laser wavelength of 355 nm and one a wavelength of 337 nm. The developed target system operated smoothly with all devices. Tryptophan, 2-deoxy-d-ribose and triphenylene showed similar desorption/ionization behaviour for all instruments using the LDI mode. Interestingly, protonated tryptophan could be observed only with the LinTOF/curved field RTOF device in LDI and MALDI mode, while sodiated molecules were observed with all three instruments (in both ion modes). Deprotonated tryptophan was almost completely obscured by matrix ions in the MALDI mode whereas LDI yielded abundant deprotonated molecules. The presented target system allowed successful analyses of the three compounds using instruments from different vendors with only one preparation showing different analyser performance characteristics. The elemental composition with the QqRTOF analyser and the high-energy 20 keV collision-induced dissociation fragmentation will be important in identifying unknown compounds in chondrites. © 2018 The Authors. Rapid Communications in Mass Spectrometry Published by John Wiley & Sons Ltd.
Optimum Operating Conditions for PZT Actuators for Vibrotactile Wearables
NASA Astrophysics Data System (ADS)
Logothetis, Irini; Matsouka, Dimitra; Vassiliadis, Savvas; Vossou, Clio; Siores, Elias
2018-04-01
Recently, vibrotactile wearables have received much attention in fields such as medicine, psychology, athletics and video gaming. The electrical components presently used to generate vibration are rigid; hence, the design and creation of ergonomical wearables are limited. Significant advances in piezoelectric components have led to the production of flexible actuators such as piezoceramic lead zirconate titanate (PZT) film. To verify the functionality of PZT actuators for use in vibrotactile wearables, the factors influencing the electromechanical conversion were analysed and tested. This was achieved through theoretical and experimental analyses of a monomorph clamped-free structure for the PZT actuator. The research performed for this article is a three-step process. First, a theoretical analysis presents the equations governing the actuator. In addition, the eigenfrequency of the film was analysed preceding the experimental section. For this stage, by applying an electric voltage and varying the stimulating electrical characteristics (i.e., voltage, electrical waveform and frequency), the optimum operating conditions for a PZT film were determined. The tip displacement was measured referring to the mechanical energy converted from electrical energy. From the results obtained, an equation for the mechanical behaviour of PZT films as actuators was deduced. It was observed that the square waveform generated larger tip displacements. In conjunction with large voltage inputs at the predetermined eigenfrequency, the optimum operating conditions for the actuator were achieved. To conclude, PZT films can be adapted to assist designers in creating comfortable vibrotactile wearables.
Optimum Operating Conditions for PZT Actuators for Vibrotactile Wearables
NASA Astrophysics Data System (ADS)
Logothetis, Irini; Matsouka, Dimitra; Vassiliadis, Savvas; Vossou, Clio; Siores, Elias
2018-07-01
Recently, vibrotactile wearables have received much attention in fields such as medicine, psychology, athletics and video gaming. The electrical components presently used to generate vibration are rigid; hence, the design and creation of ergonomical wearables are limited. Significant advances in piezoelectric components have led to the production of flexible actuators such as piezoceramic lead zirconate titanate (PZT) film. To verify the functionality of PZT actuators for use in vibrotactile wearables, the factors influencing the electromechanical conversion were analysed and tested. This was achieved through theoretical and experimental analyses of a monomorph clamped-free structure for the PZT actuator. The research performed for this article is a three-step process. First, a theoretical analysis presents the equations governing the actuator. In addition, the eigenfrequency of the film was analysed preceding the experimental section. For this stage, by applying an electric voltage and varying the stimulating electrical characteristics (i.e., voltage, electrical waveform and frequency), the optimum operating conditions for a PZT film were determined. The tip displacement was measured referring to the mechanical energy converted from electrical energy. From the results obtained, an equation for the mechanical behaviour of PZT films as actuators was deduced. It was observed that the square waveform generated larger tip displacements. In conjunction with large voltage inputs at the predetermined eigenfrequency, the optimum operating conditions for the actuator were achieved. To conclude, PZT films can be adapted to assist designers in creating comfortable vibrotactile wearables.
Williams, Jessica Roberts; Dusablon, Tracy; Williams, Weston O; Blais, Marissa Puckett; Hennessy, Kevin D
2014-07-01
Research related to the adoption of comparative effectiveness research (CER) in mental health practice is limited. This study explores the factors that influence decisions to adopt motivational interviewing (MI)-an evidence-based practice (EBP) grounded in CER-among decision-makers (n = 311) in community health organizations (n = 92). Descriptive analyses focus on organization and decision-maker characteristics and processes that may influence the decision to adopt an EBP, including demographics, structure and operations, readiness, attitudes, barriers, and facilitators. Within-group agreement is examined to determine the degree to which participants within each organization gave similar responses. Results show characteristics differed according to type of organization (community health versus community behavioral health) and position (directors versus staff). Within-group agreement was also influenced by position. These findings indicate different strategies may be needed to best disseminate CER to the two groups.
Enhanced Logistics Intra-theater Support Tool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Groningen, Charles N.; Braun, Mary Duffy; Widing, Mary Ann
2004-01-27
Developed for use by Department of Defense deployment analysts to perform detailed Reception, Staging, Onward movement and Integration (RSO&I) analyses. ELIST requires: o Vehicle characteristics for ships, planes, trucks, railcars, buses, and helicopters. o Network (physical) characteristics defining the airport, seaport, road, rail, waterway and pipeline infrastructure available in a theater of operations. o Assets available for moving the personnel, equipment and supplies over the infrastructure network. o Movement requirements plan defining the deployment requirements of a military force. This includes defining each unit, its cargo (at various levels of resolution) , where it must move from and to, whatmore » modes it is required to travel by, and when it must be delivered through each phase of deployment.« less
Predictors of shoulder dystocia at the time of operative vaginal delivery.
Palatnik, Anna; Grobman, William A; Hellendag, Madeline G; Janetos, Timothy M; Gossett, Dana R; Miller, Emily S
2016-11-01
It remains uncertain whether clinical factors known prior to delivery can predict which women are more likely to experience shoulder dystocia in the setting of operative vaginal delivery. We sought to identify whether shoulder dystocia can be accurately predicted among women undergoing an operative vaginal delivery. This was a case-control study of women undergoing a low or outlet operative vaginal delivery from 2005 through 2014 in a single tertiary care center. Cases were defined as women who experienced a shoulder dystocia at the time of operative vaginal delivery. Controls consisted of women without a shoulder dystocia at the time of operative vaginal delivery. Variables previously identified to be associated with shoulder dystocia that could be known prior to delivery were abstracted from the medical records. Bivariable analyses and multivariable logistic regression were used to identify factors independently associated with shoulder dystocia. A receiver operating characteristic curve was created to evaluate the predictive value of the model for shoulder dystocia. Of the 4080 women who met inclusion criteria, shoulder dystocia occurred in 162 (4.0%) women. In bivariable analysis, maternal age, parity, body mass index, diabetes, chorioamnionitis, arrest disorder as an indication for an operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg were significantly associated with shoulder dystocia. In multivariable analysis, parity, diabetes, chorioamnionitis, arrest disorder as an indication for operative vaginal delivery, vacuum use, and estimated fetal weight >4 kg remained independently associated with shoulder dystocia. The area under the curve for the generated receiver operating characteristic curve was 0.73 (95% confidence interval, 0.69-0.77), demonstrating only a modest ability to predict shoulder dystocia before performing an operative vaginal delivery. While risk factors for shoulder dystocia at the time of operative vaginal delivery can be identified, reliable prediction of shoulder dystocia in this setting cannot be attained. Copyright © 2016 Elsevier Inc. All rights reserved.
Outcomes of PCI in Relation to Procedural Characteristics and Operator Volumes in the United States.
Fanaroff, Alexander C; Zakroysky, Pearl; Dai, David; Wojdyla, Daniel; Sherwood, Matthew W; Roe, Matthew T; Wang, Tracy Y; Peterson, Eric D; Gurm, Hitinder S; Cohen, Mauricio G; Messenger, John C; Rao, Sunil V
2017-06-20
Professional guidelines have reduced the recommended minimum number to an average of 50 percutaneous coronary intervention (PCI) procedures performed annually by each operator. Operator volume patterns and associated outcomes since this change are unknown. The authors describe herein PCI operator procedure volumes; characteristics of low-, intermediate-, and high-volume operators; and the relationship between operator volume and clinical outcomes in a large, contemporary, nationwide sample. Using data from the National Cardiovascular Data Registry collected between July 1, 2009, and March 31, 2015, we examined operator annual PCI volume. We divided operators into low- (<50 PCIs per year), intermediate- (50 to 100 PCIs per year), and high- (>100 PCIs per year) volume groups, and determined the adjusted association between annual PCI volume and in-hospital outcomes, including mortality. The median annual number of procedures performed per operator was 59; 44% of operators performed <50 PCI procedures per year. Low-volume operators more frequently performed emergency and primary PCI procedures and practiced at hospitals with lower annual PCI volumes. Unadjusted in-hospital mortality was 1.86% for low-volume operators, 1.73% for intermediate-volume operators, and 1.48% for high-volume operators. The adjusted risk of in-hospital mortality was higher for PCI procedures performed by low- and intermediate-volume operators compared with those performed by high-volume operators (adjusted odds ratio: 1.16 for low versus high; adjusted odds ratio: 1.05 for intermediate vs. high volume) as was the risk for new dialysis post PCI. No volume relationship was observed for post-PCI bleeding. Many PCI operators in the United States are performing fewer than the recommended number of PCI procedures annually. Although absolute risk differences are small and may be partially explained by unmeasured differences in case mix between operators, there remains an inverse relationship between PCI operator volume and in-hospital mortality that persisted in risk-adjusted analyses. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Shiraishi, Junji; Pesce, Lorenzo L.; Metz, Charles E.; Doi, Kunio
2009-01-01
Purpose: To provide a broad perspective concerning the recent use of receiver operating characteristic (ROC) analysis in medical imaging by reviewing ROC studies published in Radiology between 1997 and 2006 for experimental design, imaging modality, medical condition, and ROC paradigm. Materials and Methods: Two hundred ninety-five studies were obtained by conducting a literature search with PubMed with two criteria: publication in Radiology between 1997 and 2006 and occurrence of the phrase “receiver operating characteristic.” Studies returned by the query that were not diagnostic imaging procedure performance evaluations were excluded. Characteristics of the remaining studies were tabulated. Results: Two hundred thirty-three (79.0%) of the 295 studies reported findings based on observers' diagnostic judgments or objective measurements. Forty-three (14.6%) did not include human observers, with most of these reporting an evaluation of a computer-aided diagnosis system or functional data obtained with computed tomography (CT) or magnetic resonance (MR) imaging. The remaining 19 (6.4%) studies were classified as reviews or meta-analyses and were excluded from our subsequent analysis. Among the various imaging modalities, MR imaging (46.0%) and CT (25.7%) were investigated most frequently. Approximately 60% (144 of 233) of ROC studies with human observers published in Radiology included three or fewer observers. Conclusion: ROC analysis is widely used in radiologic research, confirming its fundamental role in assessing diagnostic performance. However, the ROC studies reported in Radiology were not always adequate to support clear and clinically relevant conclusions. © RSNA, 2009 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.2533081632/-/DC1 PMID:19864510
14 CFR 25.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Turbine engine operating characteristics... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be investigated in...
14 CFR 25.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Turbine engine operating characteristics... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be investigated in...
14 CFR 25.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Turbine engine operating characteristics... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be investigated in...
14 CFR 25.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Turbine engine operating characteristics... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be investigated in...
14 CFR 25.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Turbine engine operating characteristics... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be investigated in...
Wang, Ching-Yi; Graham, James E; Karmarkar, Amol M; Reistetter, Timothy A; Protas, Elizabeth J; Ottenbacher, Kenneth J
2014-06-01
To assess the utility of functional status in classifying patients by discharge setting after inpatient rehabilitation for hip fracture. Retrospective cohort study. A total of 1257 inpatient rehabilitation facilities in the United States. Medicare beneficiaries (N = 117,168) receiving inpatient rehabilitation for hip fracture from 2007 to 2009. Receiver operating characteristic curve analyses to assess the overall discriminatory ability of functional status scores (Functional Independence Measure [FIM] total, FIM cognition, and FIM motor) and to identify the functioning threshold that best differentiates patients by discharge setting. Discharge setting (community versus institutional). Approximately 68% of patients were discharged to the community after inpatient rehabilitation for hip fracture. Receiver operating characteristic curve analyses indicate that discharge FIM motor ratings (area under the curve: 0.84) alone are as effective as a multivariable model (area under the curve: 0.85), including sociodemographic and clinical factors, in discriminating patients discharged to the community from those discharged to an institution. A discharge FIM motor rating of 58 yielded the best balance in sensitivity and specificity for classifying patients by discharge setting. Discharge FIM motor ratings demonstrated good discriminatory ability for classifying discharge setting. An FIM motor rating of 58 may serve as a clinical tool to guide treatment plans and/or as additional information in complex discharge planning decisions for patients with hip fracture. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Time-dependent summary receiver operating characteristics for meta-analysis of prognostic studies.
Hattori, Satoshi; Zhou, Xiao-Hua
2016-11-20
Prognostic studies are widely conducted to examine whether biomarkers are associated with patient's prognoses and play important roles in medical decisions. Because findings from one prognostic study may be very limited, meta-analyses may be useful to obtain sound evidence. However, prognostic studies are often analyzed by relying on a study-specific cut-off value, which can lead to difficulty in applying the standard meta-analysis techniques. In this paper, we propose two methods to estimate a time-dependent version of the summary receiver operating characteristics curve for meta-analyses of prognostic studies with a right-censored time-to-event outcome. We introduce a bivariate normal model for the pair of time-dependent sensitivity and specificity and propose a method to form inferences based on summary statistics reported in published papers. This method provides a valid inference asymptotically. In addition, we consider a bivariate binomial model. To draw inferences from this bivariate binomial model, we introduce a multiple imputation method. The multiple imputation is found to be approximately proper multiple imputation, and thus the standard Rubin's variance formula is justified from a Bayesian view point. Our simulation study and application to a real dataset revealed that both methods work well with a moderate or large number of studies and the bivariate binomial model coupled with the multiple imputation outperforms the bivariate normal model with a small number of studies. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Analysis of a Hypergolic Propellant Explosion During Processing of Launch Vehicles in the VAB
NASA Technical Reports Server (NTRS)
Chrostowski, Jon D.; Gan Wenshui; Campbell, Michael D.
2010-01-01
NASA is developing launch vehicles to support missions to Low Earth Orbit (LEO), the moon and deep space. Whether manned or unmanned, the vehicle components will likely be integrated in the Vehicle Assembly Building (VAB) at Kennedy Space Center (KSC) and typically include a fueled spacecraft (SC) that sits on top of one or more stages. The processing of a fueled SC involves hazardous operations when it is brought into the VAB Transfer Aisle and lifted a significant height for mating with lower stages. Accidents resulting from these hazardous operations could impact unrelated personnel working in buildings adjacent to the VAB. Safe separation distances based on the DOD Explosives Standards Quantity-Distance (Q-D) approach result in large IBD arcs. This paper presents site-specific air blast and fragmentation hazard analyses for comparison with the Q-D arcs as well as consequence and risk analyses to provide added information for the decision maker. A new physics-based fragmentation model is presented that includes: a) the development of a primary fragment list (which defines the fragment characteristics) associated with a hypergolic propellant explosion, b) a description of a 3D fragment bounce model, c) the results of probabilistic Monte-Carlo simulations (that include uncertainties in the fragment characteristics) to determine: i) the hazardous fragment density distance, ii) the expected number of wall/roof impacts and penetrations to over 40 buildings adjacent to the VAB, and iii) the risk to building occupants.
Lightweight moving radiators for heat rejection in space
NASA Technical Reports Server (NTRS)
Knapp, K.
1981-01-01
Low temperature droplet stream radiators, using nonmetallic fluids, can be used to radiate large amounts of waste heat from large space facilities. Moving belt radiators are suitable for use on a smaller scale, radiating as few as 10 kW from shuttle related operations. If appropriate seal technology can be developed, moving belt radiators may prove to be important for high temperature systems as well. Droplet stream radiators suitable for operation at peak temperatures near 300 K and 1000 K were studied using both freezing and nonfreezing droplets. Moving belt radiators were also investigated for operation in both temperature ranges. The potential mass and performance characteristics of both concepts were estimated on the basis of parametric variations of analytical point designs. These analyses included all consideration of the equipment required to operate the moving radiator system and take into account the mass of fluid lost by evaporation during mission lifetimes. Preliminary results indicate that low temperature droplet stream radiator appears to offer the greatest potential for improvement over conventional flat plate radiators.
Hemrich, Günter
2005-06-01
This case study reviews the experience of the Somalia Food Security Assessment Unit (FSAU) of operating a food security information system in the context of a complex emergency. In particular, it explores the linkages between selected features of the protracted crisis environment in Somalia and conceptual and operational aspects of food security information work. The paper specifically examines the implications of context characteristics for the establishment and operations of the FSAU field monitoring component and for the interface with information users and their diverse information needs. It also analyses the scope for linking food security and nutrition analysis and looks at the role of conflict and gender analysis in food security assessment work. Background data on the food security situation in Somalia and an overview of some key features of the FSAU set the scene for the case study. The paper is targeted at those involved in designing, operating and funding food security information activities.
Detection and analysis of part load and full load instabilities in a real Francis turbine prototype
NASA Astrophysics Data System (ADS)
Presas, Alexandre; Valentin, David; Egusquiza, Eduard; Valero, Carme
2017-04-01
Francis turbines operate in many cases out of its best efficiency point, in order to regulate their output power according to the instantaneous energy demand of the grid. Therefore, it is of paramount importance to analyse and determine the unstable operating points for these kind of units. In the framework of the HYPERBOLE project (FP7-ENERGY-2013-1; Project number 608532) a large Francis unit was investigated numerically, experimentally in a reduced scale model and also experimentally and numerically in the real prototype. This paper shows the unstable operating points identified during the experimental tests on the real Francis unit and the analysis of the main characteristics of these instabilities. Finally, it is shown that similar phenomena have been identified on previous research in the LMH (Laboratory for Hydraulic Machines, Lausanne) with the reduced scale model.
Model documentation renewable fuels module of the National Energy Modeling System
NASA Astrophysics Data System (ADS)
1995-06-01
This report documents the objectives, analytical approach, and design of the National Energy Modeling System (NEMS) Renewable Fuels Module (RFM) as it relates to the production of the 1995 Annual Energy Outlook (AEO95) forecasts. The report catalogs and describes modeling assumptions, computational methodologies, data inputs, and parameter estimation techniques. A number of offline analyses used in lieu of RFM modeling components are also described. The RFM consists of six analytical submodules that represent each of the major renewable energy resources -- wood, municipal solid waste (MSW), solar energy, wind energy, geothermal energy, and alcohol fuels. The RFM also reads in hydroelectric facility capacities and capacity factors from a data file for use by the NEMS Electricity Market Module (EMM). The purpose of the RFM is to define the technological, cost, and resource size characteristics of renewable energy technologies. These characteristics are used to compute a levelized cost to be competed against other similarly derived costs from other energy sources and technologies. The competition of these energy sources over the NEMS time horizon determines the market penetration of these renewable energy technologies. The characteristics include available energy capacity, capital costs, fixed operating costs, variable operating costs, capacity factor, heat rate, construction lead time, and fuel product price.
NASA Astrophysics Data System (ADS)
Lu, Zhigang; Su, Zhicheng; Wei, Yanyu
2018-05-01
A double-ridge-loaded folded waveguide (DRL-FW) travelling wave tube (TWT) based on period-tapered structure is proposed. Through analysing the dispersion characteristics of the DRL-FW slow wave structure (SWS), the physical mechanism of the band-edge oscillation is obtained. Period-tapered SWS is proposed and analysed for verifying the feasibility in suppressing upper-band-edge oscillation and increasing the output power. Then the electromagnetic characteristics and the beam-wave interaction of TWT based on the period-tapered DRL-FW SWS are investigated. The calculation results predict that it potentially could provide continuous wave power over 600W from 29 GHz to 32 GHz without upper-band-edge oscillation. The bandwidth expands from 29-31GHz to 29-32GHz and electron efficiency is increased from more than 8.3% to more than 11%, while the range of operating voltage expands from 22kV-22.5kV to 22kV-24kV. The corresponding saturated gain can reach over 36.8 dB. In addition, we have carried out experimental tests on the transmission characteristics of period-tapered DRL-FW SWS. The cold test results show that the voltage stand-wave ratio (VSWR) is below 1.8 in the range of 29-32GHz. Good transmission characteristics greatly reduce the risk of reflection wave oscillation, thus improving the stability of DRL-FW TWT.
A Children of Twins Study of parental divorce and offspring psychopathology
D'Onofrio, Brian M.; Turkheimer, Eric; Emery, Robert E.; Maes, Hermine H.; Silberg, Judy; Eaves, Lindon J.
2010-01-01
Background Although parental divorce is associated with increased substance use and internalizing problems, experiencing the separation of one's parents may not cause these outcomes. The relations may be due to genetic or environmental selection factors, characteristics that lead to both marital separation and offspring functioning. Method We used the Children of Twins (CoT) Design to explore whether unmeasured genetic or environmental factors related to the twin parent, and measured characteristics of both parents, account for the association between parental divorce and offspring substance use and internalizing problems. Results The association between parental divorce and offspring substance use problems remained robust when controlling for genetic and environmental risk from the twin parent associated with parental divorce, and measured characteristics of both parents. The results do not prove, but are consistent with, a causal connection. In contrast, the analyses suggest that shared genetic liability in parents and their offspring accounts for the increased risk of internalizing problems in adult offspring from divorced families. Conclusions The study illustrates that unmeasured genetic and environmental selection factors must be considered when studying parental divorce. In explaining associations between parental divorce and young-adult adjustment, our evidence suggests that selection versus causal mechanisms may operate differently for substance abuse (a causal relation) and internalizing problems (an artifact of selection). The CoT design only controls for the genetic and environmental characteristics of one parent; thus, additional genetically informed analyses are needed. PMID:17593147
Comprehensive experimental and numerical analysis of instability phenomena in pump turbines
NASA Astrophysics Data System (ADS)
Gentner, Ch; Sallaberger, M.; Widmer, Ch; Bobach, B.-J.; Jaberg, H.; Schiffer, J.; Senn, F.; Guggenberger, M.
2014-03-01
The changes in the electricity market have led to changed requirements for the operation of pump turbines. Utilities need to change fast and frequently between pumping and generating modes and increasingly want to operate at off-design conditions for extended periods. Operation of the units in instable areas of the machine characteristic is not acceptable and may lead to self-excited vibration of the hydraulic system. In turbine operation of pump turbines unstable behaviour can occur at low load off-design operation close to runaway conditions (S-shape of the turbine characteristic). This type of instability may impede the synchronization of the machine in turbine mode and thus increase start-up and switch over times. A pronounced S-shaped instability can also lead to significant drop of discharge in the event of load rejection. Low pressure on the suction side and in the tail-race tunnel could cause dangerous separation of the water column. Understanding the flow features that lead to the instable behaviour of pump turbines is a prerequisite to the design of machines that can fulfil the growing requirements relating to operational flexibility. Flow simulation in these instability zones is demanding due to the complex and highly unsteady flow patterns. Only unsteady simulation methods are able to reproduce the governing physical effects in these operating regions. ANDRITZ HYDRO has been investigating the stability behaviour of pump turbines in turbine operation in cooperation with several universities using simulation and measurements. In order to validate the results of flow simulation of unstable operating points, the Graz University of Technology (Austria) performed detailed experimental investigations. Within the scope of a long term research project, the operating characteristics of several pump turbine runners have been measured and flow patterns in the pump turbine at speed no load and runaway have been examined by 2D Laser particle image velocimetry (PIV). For several wicket gate positions, the flow fields in the vane-less space at runner inlet observed in the experiment are compared with the results of unsteady CFD flow simulations. Physical phenomena are visualized and insight to flow phenomena is given. Analyses using both results of simulation and measurement allow deriving a consistent explanation of the fluid mechanical mechanisms leading to the S-shaped instability of pump turbines.
Synthesis of Trigeneration Systems: Sensitivity Analyses and Resilience
Carvalho, Monica; Lozano, Miguel A.; Ramos, José; Serra, Luis M.
2013-01-01
This paper presents sensitivity and resilience analyses for a trigeneration system designed for a hospital. The following information is utilized to formulate an integer linear programming model: (1) energy service demands of the hospital, (2) technical and economical characteristics of the potential technologies for installation, (3) prices of the available utilities interchanged, and (4) financial parameters of the project. The solution of the model, minimizing the annual total cost, provides the optimal configuration of the system (technologies installed and number of pieces of equipment) and the optimal operation mode (operational load of equipment, interchange of utilities with the environment, convenience of wasting cogenerated heat, etc.) at each temporal interval defining the demand. The broad range of technical, economic, and institutional uncertainties throughout the life cycle of energy supply systems for buildings makes it necessary to delve more deeply into the fundamental properties of resilient systems: feasibility, flexibility and robustness. The resilience of the obtained solution is tested by varying, within reasonable limits, selected parameters: energy demand, amortization and maintenance factor, natural gas price, self-consumption of electricity, and time-of-delivery feed-in tariffs. PMID:24453881
Migration of the Duraloc cup after 5 years.
Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter; Windhager, Reinhard
2008-12-01
The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters > or = 54 mm migrated significantly more than cups < 54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%).
Synthesis of trigeneration systems: sensitivity analyses and resilience.
Carvalho, Monica; Lozano, Miguel A; Ramos, José; Serra, Luis M
2013-01-01
This paper presents sensitivity and resilience analyses for a trigeneration system designed for a hospital. The following information is utilized to formulate an integer linear programming model: (1) energy service demands of the hospital, (2) technical and economical characteristics of the potential technologies for installation, (3) prices of the available utilities interchanged, and (4) financial parameters of the project. The solution of the model, minimizing the annual total cost, provides the optimal configuration of the system (technologies installed and number of pieces of equipment) and the optimal operation mode (operational load of equipment, interchange of utilities with the environment, convenience of wasting cogenerated heat, etc.) at each temporal interval defining the demand. The broad range of technical, economic, and institutional uncertainties throughout the life cycle of energy supply systems for buildings makes it necessary to delve more deeply into the fundamental properties of resilient systems: feasibility, flexibility and robustness. The resilience of the obtained solution is tested by varying, within reasonable limits, selected parameters: energy demand, amortization and maintenance factor, natural gas price, self-consumption of electricity, and time-of-delivery feed-in tariffs.
Whiteman, Shawn D.; Jensen, Alexander C.; Maggs, Jennifer L.
2013-01-01
A growing body of research indicates that siblings influence each other’s risky and deviant behaviors during adolescence. Guided by research and theory on sibling similarities and differences, this study examined the operation and implications of three different influence processes--social learning, shared friends, and sibling differentiation--during adolescence. Participants included one parent and two adolescent siblings (earlier born age: M = 17.17 years, SD = 0.94; later born age: M = 14.52 years, SD = 1.27) from 326 families. Data were collected via telephone interviews. Using reports from both older and younger siblings, two-stage cluster analyses revealed three influence profiles: mutual modeling and shared friends, younger sibling admiration, and differentiation. Additional analyses revealed that mutual modeling and shared friends as well as younger sibling admiration were linked to similarities in brothers’ and sisters’ health-risk behaviors and attitudes, whereas differentiation processes were associated with divergence in siblings’ characteristics. The discussion focuses on refining the study of sibling influence, with particular attention paid to the operation and implications of both convergent and divergent influence processes. PMID:23765197
Low Shrinkage Cement Concrete Intended for Airfield Pavements
NASA Astrophysics Data System (ADS)
Małgorzata, Linek
2017-10-01
The work concerns the issue of hardened concrete parameters improvement intended for airfield pavements. Factors which have direct or indirect influence on rheological deformation size were of particular interest. The aim of lab testing was to select concrete mixture ratio which would make hardened concrete less susceptible to influence of basic operating factors. Analyses included two research groups. External and internal factors were selected. They influence parameters of hardened cement concrete by increasing rheological deformations. Research referred to innovative cement concrete intended for airfield pavements. Due to construction operation, the research considered the influence of weather conditions and forced thermal loads intensifying concrete stress. Fresh concrete mixture parameters were tested and basic parameters of hardened concrete were defined (density, absorbability, compression strength, tensile strength). Influence of the following factors on rheological deformation value was also analysed. Based on obtained test results, it has been discovered that innovative concrete, made on the basis of modifier, which changes internal structure of concrete composite, has definitely lower values of rheological deformation. Observed changes of microstructure, in connection with reduced deformation values allowed to reach the conclusion regarding advantageous characteristic features of the newly designed cement concrete. Applying such concrete for airfield construction may contribute to extension of its operation without malfunction and the increase of its general service life.
14 CFR 27.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 27.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 27.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 29.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 29.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 29.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 29.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 27.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 27.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
14 CFR 29.939 - Turbine engine operating characteristics.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Turbine engine operating characteristics....939 Turbine engine operating characteristics. (a) Turbine engine operating characteristics must be... limitations of the rotorcraft and of the engine. (b) The turbine engine air inlet system may not, as a result...
Evans, Kris; Rotello, Caren M; Li, Xingshan; Rayner, Keith
2009-02-01
Cultural differences have been observed in scene perception and memory: Chinese participants purportedly attend to the background information more than did American participants. We investigated the influence of culture by recording eye movements during scene perception and while participants made recognition memory judgements. Real-world pictures with a focal object on a background were shown to both American and Chinese participants while their eye movements were recorded. Later, memory for the focal object in each scene was tested, and the relationship between the focal object (studied, new) and the background context (studied, new) was manipulated. Receiver-operating characteristic (ROC) curves show that both sensitivity and response bias were changed when objects were tested in new contexts. However, neither the decrease in accuracy nor the response bias shift differed with culture. The eye movement patterns were also similar across cultural groups. Both groups made longer and more fixations on the focal objects than on the contexts. The similarity of eye movement patterns and recognition memory behaviour suggests that both Americans and Chinese use the same strategies in scene perception and memory.
Kakinuma, Ryutaro; Kodama, Ken; Yamada, Kouzo; Yokoyama, Akira; Adachi, Shuji; Mori, Kiyoshi; Fukuyama, Yasuro; Fukuda, Yasuro; Kuriyama, Keiko; Oda, Junichi; Oda, Junji; Noguchi, Masayuki; Matsuno, Yoshihiro; Yokose, Tomoyuki; Ohmatsu, Hironobu; Nishiwaki, Yutaka
2008-01-01
To evaluate the performance of 4 methods of measuring the extent of ground-glass opacities as a means of predicting the 5-year relapse-free survival of patients with peripheral nonsmall cell lung cancer (NSLC). Ground-glass opacities on thin-section computed tomographic images of 120 peripheral NSLCs were measured at 7 medical institutions by the length, area, modified length, and vanishing ratio (VR) methods. The performance (Az) of each method in predicting the 5-year relapse-free survival was evaluated using receiver operating characteristic analysis. The mean Az value obtained by the length, area, modified length, and VR methods in the receiver operating characteristic analyses was 0.683, 0.702, 0.728, and 0.784, respectively. The differences between the mean Az value obtained by the VR method and by the other 3 methods were significant. Vanishing ratio method was the most accurate predictor of the 5-year relapse-free survival of patients with peripheral NSLC.
Booster Main Engine Selection Criteria for the Liquid Fly-Back Booster
NASA Technical Reports Server (NTRS)
Ryan, Richard M.; Rothschild, William J.; Christensen, David L.
1998-01-01
The Liquid Fly-Back Booster (LFBB) Program seeks to enhance the Space Shuttle system safety performance and economy of operations through the use of an advanced, liquid propellant Booster Main Engine (BME). There are several viable BME candidates that could be suitable for this application. The objective of this study was to identify the key criteria to be applied in selecting among these BME candidates. This study involved an assessment of influences on the overall LFBB utility due to variations in the candidate rocket engines' characteristics. This includes BME impacts on vehicle system weight, perfortnance,design approaches, abort modes, margins of safety, engine-out operations, and maintenance and support concepts. Systems engineering analyses and trade studies were performed to identify the LFBB system level sensitivities to a wide variety of BME related parameters. This presentation summarizes these trade studies and the resulting findings of the LFBB design teams regarding the BME characteristics that most significantly affect the LFBB system. The resulting BME choice should offer the best combination of reliability, performance, reusability, robustness, cost, and risk for the LFBB program.
Booster Main Engine Selection Criteria for the Liquid Fly-Back Booster
NASA Technical Reports Server (NTRS)
Ryan, Richard M.; Rothschild, William J.; Christensen, David L.
1998-01-01
The Liquid Fly-Back Booster (LFBB) Program seeks to enhance the Space Shuttle system safety, performance and economy of operations through the use of an advanced, liquid propellant Booster Main Engine (BME). There are several viable BME candidates that could be suitable for this application. The objective of this study was to identify the key Criteria to be applied in selecting among these BME candidates. This study involved an assessment of influences on the overall LFBB utility due to variations in the candidate rocket-engines characteristics. This includes BME impacts on vehicle system weight, performance, design approaches, abort modes, margins of safety, engine-out operations, and maintenance and support concepts. Systems engineering analyses and trade studies were performed to identify the LFBB system level sensitivities to a wide variety of BME related parameters. This presentation summarizes these trade studies and the resulting findings of the LFBB design teams regarding the BME characteristics that most significantly affect the LFBB system. The resulting BME choice should offer the best combination of reliability, performance, reusability, robustness, cost, and risk for the LFBB program.
Self-injurious behaviour in people with intellectual disability and autism spectrum disorder.
Oliver, Chris; Licence, Lucy; Richards, Caroline
2017-03-01
This review summarises the recent trends in research in the field of self-injurious behaviour in people with intellectual disability and autism spectrum disorder. New data on incidence, persistence and severity add to studies of prevalence to indicate the large scale of the clinical need. A number of person characteristics have been repeatedly identified in prevalence and cohort studies that: can be considered as risk markers (e.g. stereotyped behaviour, autism spectrum disorder) and indicate possible causal mechanisms (e.g. sleep disorder, anxiety). Studies have started to integrate traditional operant learning paradigms with known person characteristics and reviews and meta-analyses of applied behaviour analytic procedures can now inform practice. Despite these positive developments interventions and appropriate support falls far short of the required need. Expansions in applied research are warranted to develop and evaluate innovative service delivery models that can translate knowledge of risk markers and operant learning paradigms into widespread, low cost routine clinical practice. Alongside this, further pure research is needed to elucidate the direction of causality of implicated risk factors, in order to understand and intervene more effectively in self-injury.
Naeem, Muhammad Awais; Armutlulu, Andac; Imtiaz, Qasim; Donat, Felix; Schäublin, Robin; Kierzkowska, Agnieszka; Müller, Christoph R
2018-06-19
Calcium looping, a CO 2 capture technique, may offer a mid-term if not near-term solution to mitigate climate change, triggered by the yet increasing anthropogenic CO 2 emissions. A key requirement for the economic operation of calcium looping is the availability of highly effective CaO-based CO 2 sorbents. Here we report a facile synthesis route that yields hollow, MgO-stabilized, CaO microspheres featuring highly porous multishelled morphologies. As a thermal stabilizer, MgO minimized the sintering-induced decay of the sorbents' CO 2 capacity and ensured a stable CO 2 uptake over multiple operation cycles. Detailed electron microscopy-based analyses confirm a compositional homogeneity which is identified, together with the characteristics of its porous structure, as an essential feature to yield a high-performance sorbent. After 30 cycles of repeated CO 2 capture and sorbent regeneration, the best performing material requires as little as 11 wt.% MgO for structural stabilization and exceeds the CO 2 uptake of the limestone-derived reference material by ~500%.
NASA Astrophysics Data System (ADS)
Stamenkovic, Dragan D.; Popovic, Vladimir M.
2015-02-01
Warranty is a powerful marketing tool, but it always involves additional costs to the manufacturer. In order to reduce these costs and make use of warranty's marketing potential, the manufacturer needs to master the techniques for warranty cost prediction according to the reliability characteristics of the product. In this paper a combination free replacement and pro rata warranty policy is analysed as warranty model for one type of light bulbs. Since operating conditions have a great impact on product reliability, they need to be considered in such analysis. A neural network model is used to predict light bulb reliability characteristics based on the data from the tests of light bulbs in various operating conditions. Compared with a linear regression model used in the literature for similar tasks, the neural network model proved to be a more accurate method for such prediction. Reliability parameters obtained in this way are later used in Monte Carlo simulation for the prediction of times to failure needed for warranty cost calculation. The results of the analysis make possible for the manufacturer to choose the optimal warranty policy based on expected product operating conditions. In such a way, the manufacturer can lower the costs and increase the profit.
NASA Technical Reports Server (NTRS)
Hanson, Frederick H
1945-01-01
Tests were made of a model representative of a single-engine tractor-type airplane for the purpose of determining the stability and control effects of a propeller used as an aerodynamic brake. The tests were made with single-and dual-rotation propellers to show the effect of type of propeller rotation, and with positive thrust to provide basic data with which to compare the effects of negative thrust. Four configurations of the model were used to give the effects of tilting the propeller thrust axis down 5 deg., raising the horizontal tail, and combining both tilt and raised tail. Results of the tests are reported herein. The effects of negative thrust were found to be significant. The longitudinal stability was increased because of the loss of wing lift and increase of the angle of attack of the tail. Directional stability and both longitudinal and directional control were decreased because of the reduced velocity at the tail. These effects are moderate for moderate braking but become pronounced with full-power braking, particularly at high values of lift coefficient. The effects of model configuration changes were small when compared with the over-all effects of negative-thrust operation; however, improved stability and control characteristics were exhibited by the model with the tilted thrust axis. Raising the horizontal tail improved the longitudinal characteristics, but was detrimental to directional characteristics. The use of dual-rotation propeller reduced the directional trim charges resulting from the braking operation. A prototype airplane was assumed and handling qualities were computed and analyzed for normal (positive thrust) and braking operation with full and partial power. The results of these analyses are presented for the longitudinal characteristics in steady and accelerated flight, and for the directional characteristics in high- and low-speed flight. It was found that by limiting the power output of the engine (assuming the constant-speed propeller will function in the range of blade angles required for negative thrust) the stability and control characteristics may be held within the limits required for safe operation. Braking with full power, particularly at low speeds, is dangerous, but braking with very small power output is satisfactory from the standpoint of control. The amount of braking produced with zero power output is equal to or better than that produced by conventional spoiler-type brakes.
Low power consumption resistance random access memory with Pt/InOx/TiN structure
NASA Astrophysics Data System (ADS)
Yang, Jyun-Bao; Chang, Ting-Chang; Huang, Jheng-Jie; Chen, Yu-Ting; Tseng, Hsueh-Chih; Chu, Ann-Kuo; Sze, Simon M.; Tsai, Ming-Jinn
2013-09-01
In this study, the resistance switching characteristics of a resistive random access memory device with Pt/InOx/TiN structure is investigated. Unstable bipolar switching behavior is observed during the initial switching cycle, which then stabilizes after several switching cycles. Analyses indicate that the current conduction mechanism in the resistance state is dominated by Ohmic conduction. The decrease in electrical conductance can be attributed to the reduction of the cross-sectional area of the conduction path. Furthermore, the device exhibits low operation voltage and power consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pavlov, S V; Trofimov, N S; Chekhlova, T K
2014-07-31
A possibility of designing optical waveguide devices based on sol – gel SiO{sub 2} – TiO{sub 2} films using the temperature dependence of the effective refractive index is shown. The dependences of the device characteristics on the parameters of the film and opticalsystem elements are analysed. The operation of a temperature recorder and a temperature limiter with a resolution of 0.6 K mm{sup -1} is demonstrated. The film and output-prism parameters are optimised. (fibreoptic and nonlinear-optic devices)
Angular Distributions of Discrete Mesoscale Mapping Functions
NASA Astrophysics Data System (ADS)
Kroszczyński, Krzysztof
2015-08-01
The paper presents the results of analyses of numerical experiments concerning GPS signal propagation delays in the atmosphere and the discrete mapping functions defined on their basis. The delays were determined using data from the mesoscale non-hydrostatic weather model operated in the Centre of Applied Geomatics, Military University of Technology. A special attention was paid to investigating angular characteristics of GPS slant delays for low angles of elevation. The investigation proved that the temporal and spatial variability of the slant delays depends to a large extent on current weather conditions.
NASA Astrophysics Data System (ADS)
Sipaun, S.
2017-01-01
Current development in thorium fueled reactors shows that they can be designed to operate in the fast or thermal spectrum. The thorium/uranium fuel cycle converts fertile thorium-232 into fissile uranium-233, which fissions and releases energy. This paper analyses the characteristics of thorium fueled reactors and discusses the thermal reactor option. It is found that thorium fuel can be utilized in molten salt reactors through many configurations and designs. A balanced assessment on the feasibility of adopting one reactor technology versus another could lead to optimized benefits of having thorium resource.
49 CFR 234.205 - Operating characteristics of warning system apparatus.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Operating characteristics of warning system... Maintenance Standards § 234.205 Operating characteristics of warning system apparatus. Operating... system shall be maintained in accordance with the limits within which the system is designed to operate. ...
49 CFR 234.205 - Operating characteristics of warning system apparatus.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Operating characteristics of warning system... Maintenance Standards § 234.205 Operating characteristics of warning system apparatus. Operating... system shall be maintained in accordance with the limits within which the system is designed to operate. ...
49 CFR 234.205 - Operating characteristics of warning system apparatus.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Operating characteristics of warning system... Maintenance Standards § 234.205 Operating characteristics of warning system apparatus. Operating... system shall be maintained in accordance with the limits within which the system is designed to operate. ...
Ishii, Yoshinori; Noguchi, Hideo; Takeda, Mitsuhiro; Sato, Junko; Toyabe, Shin-Ichi
2014-01-01
The purpose of this study was to evaluate the interval between the first and second operations for staged total knee arthroplasties (TKAs) in patients with bilateral knee osteoarthritis. Depending on satisfactory preoperative health status, the patients determined the timing of the second operation. We also analysed correlations between the interval and patient characteristics. Eighty-six patients with bilateral knee osteoarthritis were analysed. The mean follow-up time from the first TKA was 96 months. The side of the first TKA was chosen by the patients. The timing of the second TKA was determined by the patients, depending on their perceived ability to tolerate the additional pain and limitations to activities of daily living. The median interval between the first and second operations was 12.5 months, with a range of 2 to 113 months. In 43 (50%) patients, the interval was <12 months. There was no difference in the interval between females and males (p=0.861), and no correlation between the interval and body mass index or age. There was weak correlation between the year of the first TKA and the interval (R=-0.251, p=0.020), with the interval getting significantly shorter as the years progressed (p=0.032). The median interval between the first and second operations in patients who underwent staged TKAs for bilateral knee osteoarthritis was about 1 year. The results of the current study may help patients and physicians to plan effective treatment strategies for staged TKAs. Level II. Copyright © 2013 Elsevier B.V. All rights reserved.
33 CFR 157.158 - COW operations: Changed characteristics.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false COW operations: Changed... CARRYING OIL IN BULK Crude Oil Washing (COW) System on Tank Vessels Cow Operations § 157.158 COW operations: Changed characteristics. The COW system may be operated with characteristics that do not meet those...
Empirical evidence of the importance of comparative studies of diagnostic test accuracy.
Takwoingi, Yemisi; Leeflang, Mariska M G; Deeks, Jonathan J
2013-04-02
Systematic reviews that "compare" the accuracy of 2 or more tests often include different sets of studies for each test. To investigate the availability of direct comparative studies of test accuracy and to assess whether summary estimates of accuracy differ between meta-analyses of noncomparative and comparative studies. Systematic reviews in any language from the Database of Abstracts of Reviews of Effects and the Cochrane Database of Systematic Reviews from 1994 to October 2012. 1 of 2 assessors selected reviews that evaluated at least 2 tests and identified meta-analyses that included both noncomparative studies and comparative studies. 1 of 3 assessors extracted data about review and study characteristics and test performance. 248 reviews compared test accuracy; of the 6915 studies, 2113 (31%) were comparative. Thirty-six reviews (with 52 meta-analyses) had adequate studies to compare results of noncomparative and comparative studies by using a hierarchical summary receiver-operating characteristic meta-regression model for each test comparison. In 10 meta-analyses, noncomparative studies ranked tests in the opposite order of comparative studies. A total of 25 meta-analyses showed more than a 2-fold discrepancy in the relative diagnostic odds ratio between noncomparative and comparative studies. Differences in accuracy estimates between noncomparative and comparative studies were greater than expected by chance (P < 0.001). A paucity of comparative studies limited exploration of direction in bias. Evidence derived from noncomparative studies often differs from that derived from comparative studies. Robustly designed studies in which all patients receive all tests or are randomly assigned to receive one or other of the tests should be more routinely undertaken and are preferred for evidence to guide test selection. National Institute for Health Research (United Kingdom).
Dynamic properties of small-scale solar wind plasma fluctuations.
Riazantseva, M O; Budaev, V P; Zelenyi, L M; Zastenker, G N; Pavlos, G P; Safrankova, J; Nemecek, Z; Prech, L; Nemec, F
2015-05-13
The paper presents the latest results of the studies of small-scale fluctuations in a turbulent flow of solar wind (SW) using measurements with extremely high temporal resolution (up to 0.03 s) of the bright monitor of SW (BMSW) plasma spectrometer operating on astrophysical SPECTR-R spacecraft at distances up to 350,000 km from the Earth. The spectra of SW ion flux fluctuations in the range of scales between 0.03 and 100 s are systematically analysed. The difference of slopes in low- and high-frequency parts of spectra and the frequency of the break point between these two characteristic slopes was analysed for different conditions in the SW. The statistical properties of the SW ion flux fluctuations were thoroughly analysed on scales less than 10 s. A high level of intermittency is demonstrated. The extended self-similarity of SW ion flux turbulent flow is constantly observed. The approximation of non-Gaussian probability distribution function of ion flux fluctuations by the Tsallis statistics shows the non-extensive character of SW fluctuations. Statistical characteristics of ion flux fluctuations are compared with the predictions of a log-Poisson model. The log-Poisson parametrization of the structure function scaling has shown that well-defined filament-like plasma structures are, as a rule, observed in the turbulent SW flows. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Do state characteristics matter? State level factors related to tobacco cessation quitlines
Keller, Paula A; Koss, Kalsea J; Baker, Timothy B; Bailey, Linda A; Fiore, Michael C
2007-01-01
Background Quitline services are an effective population‐wide tobacco cessation strategy adopted widely in the United States as part of state comprehensive tobacco control efforts. Despite widespread evidence supporting quitlines' effectiveness, many states lack sufficient financial resources to adequately fund and promote this service. Efforts to augment state tobacco control efforts might be fostered by greater knowledge of state level factors associated with the funding and implementation of those efforts. Methods We analysed data from the 2004 North American Quitline Consortium survey and from publicly available sources to identify state level factors related to quitline implementation and funding. Factors included in the analyses were state demographic characteristics, tobacco use variables, state tobacco control spending, and economic and political climate variables. Univariate and multivariate regression analyses were conducted. Results The best fitting multivariate model that significantly predicted the presence or absence of a state quitline included only cigarette excise tax rate (p = 0.020). In terms of funding levels, states with high rates of cigarette consumption (p = 0.047) and with higher per capita expenditures for tobacco control programmes (p = 0 .0.004) were most likely to spend more on per capita operations budget for quitlines. Conclusion State level factors appear to play a part in whether states had established quitlines by mid‐2004 and the amount of per capita quitline funding. PMID:18048637
VALVES FOR THE HIGH PRESSURE-HIGH TEMPERATURE (HP-HT) FLUORINATION SYSTEM. (Engineering Materials)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1963-10-31
This package contains two drawings of valves which eliminate errors in the gravimetric oxide dilution procedure of U/sup 235/ measurement. Isotopic contaminatioNonen in the high pressure fluorination reactor was corrected by changing the manner in which the Cu tubing joins the valve and by modification of the bellows. The compact inlet system was modified to improve the precision of the spectrometer analyses. Changes were raade in the basic leak and the air operator, which is a diaphragm-type valve, so that the setting of the flow level is controlled by the closure spring adjustment screw. This capillary-type leak has increased controlmore » range and sraooth control characteristics. It is simple to construct, is remotely operated and is free from corrosion failure. (F.S.)« less
NASA-ONERA Collaboration on Human Factors in Aviation Accidents and Incidents
NASA Technical Reports Server (NTRS)
Srivastava, Ashok N.; Fabiani, Patrick
2012-01-01
This is the first annual report jointly prepared by NASA and ONERA on the work performed under the agreement to collaborate on a study of the human factors entailed in aviation accidents and incidents, particularly focused on the consequences of decreases in human performance associated with fatigue. The objective of this agreement is to generate reliable, automated procedures that improve understanding of the levels and characteristics of flight-crew fatigue factors whose confluence will likely result in unacceptable crew performance. This study entails the analyses of numerical and textual data collected during operational flights. NASA and ONERA are collaborating on the development and assessment of automated capabilities for extracting operationally significant information from very large, diverse (textual and numerical) databases; much larger than can be handled practically by human experts.
NASA Astrophysics Data System (ADS)
Kishore, P.; Kathiravan, C.
The level of radio emission from the Sun and other celestial sources that we receive on the Earth is very low when compared to those generated here (e.g. by TV and radio broadcasting stations, engines of automobiles and industrial equipment). Therefore, it requires technically advanced systems to detect those weak emissions in order to study their characteristics, generation mechanisms, etc. - one of the interests of human race to enhance its knowledge about space and its entities. Although inevitable and became part of life, the civilian radio broadcast, communication networks are capable of affecting such observations directly. Studies show that eliminating such interferences at an early stage improves not only the analyses but also the reliability of the results. Towards this an attempt is made to alter the characteristics of an antenna since it is the foremost component of any radio receiver system. The tests are made with a Log-periodic dipole antenna (LPDA) and the changes in the reception characteristics over a few set of undesired frequency bands are discussed here.
Changes in smoking habits of smokers under bombing by rockets.
Keinan-Boker, L; Enav, T; Rozentraub, T; Shohat, T
2011-03-01
Stress is known to impact smoking. This survey assessed changes in smoking behaviour of smokers in Southern Israel during a military operation (December 2008-January 2009) that exposed several civilian communities to intensive rocket bombing and acute stress. Households with an active land telephone line in Jewish Gaza vicinity communities were sampled. Inclusion criteria were age (18+ years) and being a daily or an occasional smoker. A telephone interview was carried out, focusing on socio-demographic characteristics and change in smoking behaviour during the military operation. Personal, demographic and circumstantial correlates of smoking behaviour were assessed using univariate and multivariate analyses. A total of 425 smokers took part in the survey. Most (85%) reported being daily smokers, and smoked, on average, 10-20 cigarettes/day before the operation. During the operation, 38% of the smokers changed their smoking habits and most (88%) reported higher than usual smoking rates. Correlates significantly associated with higher smoking during the operation were sex (female), education (lower) and not working due to the operation. Exposure to acute stress has an impact on smoking rates, especially in certain subgroups of smokers. Relevant smoking cessation interventions should address the special needs of smokers exposed to stressful circumstances.
Value of MR histogram analyses for prediction of microvascular invasion of hepatocellular carcinoma.
Huang, Ya-Qin; Liang, He-Yue; Yang, Zhao-Xia; Ding, Ying; Zeng, Meng-Su; Rao, Sheng-Xiang
2016-06-01
The objective is to explore the value of preoperative magnetic resonance (MR) histogram analyses in predicting microvascular invasion (MVI) of hepatocellular carcinoma (HCC).Fifty-one patients with histologically confirmed HCC who underwent diffusion-weighted and contrast-enhanced MR imaging were included. Histogram analyses were performed and mean, variance, skewness, kurtosis, 1th, 10th, 50th, 90th, and 99th percentiles were derived. Quantitative histogram parameters were compared between HCCs with and without MVI. Receiver operating characteristics (ROC) analyses were generated to compare the diagnostic performance of tumor size, histogram analyses of apparent diffusion coefficient (ADC) maps, and MR enhancement.The mean, 1th, 10th, and 50th percentiles of ADC maps, and the mean, variance. 1th, 10th, 50th, 90th, and 99th percentiles of the portal venous phase (PVP) images were significantly different between the groups with and without MVI (P <0.05), with area under the ROC curves (AUCs) of 0.66 to 0.74 for ADC and 0.76 to 0.88 for PVP. The largest AUC of PVP (1th percentile) showed significantly higher accuracy compared with that of arterial phase (AP) or tumor size (P <0.001).MR histogram analyses-in particular for 1th percentile for PVP images-held promise for prediction of MVI of HCC.
NASA Technical Reports Server (NTRS)
Margasahayam, Ravi N.; Meyer, Karl A.; Nerolich, Shaun M.; Burton, Roy C.; Gosselin, Armand M.
2004-01-01
The Crawler Transporter (CT), designed and built for the Apollo Program in the 1960's and surpassing its initial operational life, has become an integral part of the Space Shuttle Program (SSP). The CT transports the Space Shuttle Vehicle (SSV) stack, atop the Mobile Launch Platform (MLP), from the Vehicle Assembly Building (VAB) to the launch pad. This support structure provides hydraulic jacking, leveling and load equalization for the 12 million pound stack on its 3.5-5.0 mile rollout to the launch pad. Major elements of the SSV, consisting of the orbiter, solid rocket boosters (SRB) and external tank (ET) have required fatigue analyses as part of the mission life certification. Compared to rollout vibration, the SSV sees relatively high vibration loads during launch, ascent, descent and landing phases of the mission. Although preliminary measured SRB vibration levels during rollout were of low amplitude and frequency, the duration of the rollout phase is typically high, from 5-6 hours. As part of an expanded mission life assessment, additional certification effort was initiated to define fatigue load spectra for rollout. This study addresses the CT vibration analyses in support of the rollout fatigue study. Structural models developed for modal and vibration analyses were used to identify unique CT, CT/MLP and CT/MLP/SRB vibration characteristics for comparison to instrumented rollout tests. Whereas the main structural and vibration characteristics of the SSV are well defined, minimum analytical and vibration test data on the Crawler Transporter were available. Unique vibration characteristics of the CT are attributable to the drive mechanism, hydraulic jacking system, structural framing and the CT-to-MLP support pad restraints. Initial tests performed on the CT/MLP/SRB configuration showed reasonable correlation with predicted mode shapes and frequencies.
Chouvenc, P; Vessot, S; Andrieu, J; Vacus, P
2005-01-01
The principal aim of this study is to extend to a pilot freeze-dryer equipped with a non-instantaneous isolation valve the previously presented pressure rise analysis (PRA) model for monitoring the product temperature and the resistance to mass transfer of the dried layer during primary drying. This method, derived from the original MTM method previously published, consists of interrupting rapidly (a few seconds) the water vapour flow from the sublimation chamber to the condenser and analysing the resulting dynamics of the total chamber pressure increase. The valve effect on the pressure rise profile observed during the isolation valve closing period was corrected by introducing in the initial PRA model a valve characteristic function factor which turned out to be independent of the operating conditions. This new extended PRA model was validated by implementing successively the two types of valves and by analysing the pressure rise kinetics data with the corresponding PRA models in the same operating conditions. The coherence and consistency shown on the identified parameter values (sublimation front temperature, dried layer mass transfer resistance) allowed validation of this extended PRA model with a non-instantaneous isolation valve. These results confirm that the PRA method, with or without an instantaneous isolation valve, is appropriate for on-line monitoring of product characteristics during freeze-drying. The advantages of PRA are that the method is rapid, non-invasive, and global. Consequently, PRA might become a powerful and promising tool not only for the control of pilot freeze-dryers but also for industrial freeze-dryers equipped with external condensers.
A novel structural risk index for primary spontaneous pneumothorax: Ankara Numune Risk Index.
Akkas, Yucel; Peri, Neslihan Gulay; Kocer, Bulent; Kaplan, Tevfik; Alhan, Aslihan
2017-07-01
In this study, we aimed to reveal a novel risk index as a structural risk marker for primary spontanoeus pneumothorax using body mass index and chest height, structural risk factors for pneumothorax development. Records of 86 cases admitted between February 2014 and January 2015 with or without primary spontaneous pneumothorax were analysed retrospectively. The patients were allocated to two groups as Group I and Group II. The patients were evaluated with regard to age, gender, pneumothorax side, duration of hospital stay, treatment type, recurrence, chest height and transverse diameter on posteroanterior chest graphy and body mass index. Body mass index ratio per cm of chest height was calculated by dividing body mass index with chest height. We named this risk index ratio which is defined first as 'Ankara Numune Risk Index'. Diagnostic value of Ankara Numune Risk Index value for prediction of primary spontaneous pneumothorax development was analysed with Receiver Operating Characteristics curver. Of 86 patients, 69 (80.2%) were male and 17 (19.8%) were female. Each group was composed of 43 (50%) patients. When Receiver Operating Characteristics curve analysis was done for optimal limit value 0.74 of Ankara Numune Risk Index determined for prediction of pneumothorax development risk, area under the curve was 0.925 (95% Cl, 0.872-0.977, p < 0.001). Ankara Numune Risk Index is one of the structural risk factors for prediction of primary spontaneous pneumothorax development however it is insufficient for determining recurrence. Copyright © 2015. Published by Elsevier Taiwan.
Nishikawa, Hiroki; Nishijima, Norihiro; Enomoto, Hirayuki; Sakamoto, Azusa; Nasu, Akihiro; Komekado, Hideyuki; Nishimura, Takashi; Kita, Ryuichi; Kimura, Toru; Iijima, Hiroko; Nishiguchi, Shuhei; Osaki, Yukio
2017-01-01
To investigate variables before sorafenib therapy on the clinical outcomes in hepatocellular carcinoma (HCC) patients receiving sorafenib and to further assess and compare the predictive performance of continuous parameters using time-dependent receiver operating characteristics (ROC) analysis. A total of 225 HCC patients were analyzed. We retrospectively examined factors related to overall survival (OS) and progression free survival (PFS) using univariate and multivariate analyses. Subsequently, we performed time-dependent ROC analysis of continuous parameters which were significant in the multivariate analysis in terms of OS and PFS. Total sum of area under the ROC in all time points (defined as TAAT score) in each case was calculated. Our cohort included 175 male and 50 female patients (median age, 72 years) and included 158 Child-Pugh A and 67 Child-Pugh B patients. The median OS time was 0.68 years, while the median PFS time was 0.24 years. On multivariate analysis, gender, body mass index (BMI), Child-Pugh classification, extrahepatic metastases, tumor burden, aspartate aminotransferase (AST) and alpha-fetoprotein (AFP) were identified as significant predictors of OS and ECOG-performance status, Child-Pugh classification and extrahepatic metastases were identified as significant predictors of PFS. Among three continuous variables (i.e., BMI, AST and AFP), AFP had the highest TAAT score for the entire cohort. In subgroup analyses, AFP had the highest TAAT score except for Child-Pugh B and female among three continuous variables. In continuous variables, AFP could have higher predictive accuracy for survival in HCC patients undergoing sorafenib therapy.
Ultrasound predictors of placental invasion: the Placenta Accreta Index.
Rac, Martha W F; Dashe, Jodi S; Wells, C Edward; Moschos, Elysia; McIntire, Donald D; Twickler, Diane M
2015-03-01
We sought to apply a standardized evaluation of ultrasound parameters for the prediction of placental invasion in a high-risk population. This was a retrospective review of gravidas with ≥1 prior cesarean delivery who received an ultrasound diagnosis of placenta previa or low-lying placenta in the third trimester at our institution from 1997 through 2011. Sonographic images were reviewed by an investigator blinded to pregnancy outcome and sonography reports. Parameters assessed included loss of retroplacental clear zone, irregularity and width of uterine-bladder interface, smallest myometrial thickness, presence of lacunar spaces, and bridging vessels. Diagnosis of placental invasion was based on histologic confirmation. Statistical analyses were performed using linear logistic regression and multiparametric analyses to generate a predictive equation evaluated using a receiver operating characteristic curve. Of 184 gravidas who met inclusion criteria, 54 (29%) had invasion confirmed on hysterectomy specimen. All sonographic parameters were associated with placental invasion (P < .001). Constructing a receiver operating characteristic curve, the combination of smallest sagittal myometrial thickness, lacunae, and bridging vessels, in addition to number of cesarean deliveries and placental location, yielded an area under the curve of 0.87 (95% confidence interval, 0.80-0.95). Using logistic regression, a predictive equation was generated, termed the "Placenta Accreta Index." Each parameter was weighted to create a 9-point scale in which a score of 0-9 provided a probability of invasion that ranged from 2-96%, respectively. Assignment of the Placenta Accreta Index may be helpful in predicting individual patient risk for morbidly adherent placenta. Copyright © 2015 Elsevier Inc. All rights reserved.
Liu, Jianguo; Jiang, Xiumin; Zhou, Lingsheng; Wang, Hui; Han, Xiangxin
2009-08-15
Incineration has been proven to be an alternative for disposal of sludge with its unique characteristics to minimize the volume and recover energy. In this paper, a new fluidized bed (FB) incineration system for treating oil sludge is presented. Co-firing of oil sludge with coal-water slurry (CWS) was investigated in the new incineration system to study combustion characteristics, gaseous pollutant emissions and ash management. The study results show the co-firing of oil sludge with CWS in FB has good operating characteristic. CWS as an auxiliary fuel can flexibly control the dense bed temperatures by adjusting its feeding rate. All emissions met the local environmental requirements. The CO emission was less than 1 ppm or essentially zero; the emissions of SO(2) and NO(x) were 120-220 and 120-160 mg/Nm(3), respectively. The heavy metal analyses of the bottom ash and the fly ash by ICP/AES show that the combustion ashes could be recycled as soil for farming.
A Circular Microstrip Antenna Sensor for Direction Sensitive Strain Evaluation.
Lopato, Przemyslaw; Herbko, Michal
2018-01-20
In this paper, a circular microstrip antenna for stress evaluation is studied. This kind of microstrip sensor can be utilized in structural health monitoring systems. Reflection coefficient S 11 is measured to determine deformation/strain value. The proposed sensor is adhesively connected to the studied sample. Applied strain causes a change in patch geometry and influences current distribution both in patch and ground plane. Changing the current flow in patch influences the value of resonant frequency. In this paper, two different resonant frequencies were analysed because in each case, different current distributions in patch were obtained. The sensor was designed for operating frequency of 2.5 GHz (at fundamental mode), which results in a diameter less than 55 mm. Obtained sensitivity was up to 1 MHz/100 MPa, resolution depends on utilized vector network analyser. Moreover, the directional characteristics for both resonant frequencies were defined, studied using numerical model and verified by measurements. Thus far, microstrip antennas have been used in deformation measurement only if the direction of external force was well known. Obtained directional characteristics of the sensor allow the determination of direction and value of stress by one sensor. This method of measurement can be an alternative to the rosette strain gauge.
Noise measurement flight test: Data-analyses Aerospatiale SA-365N Dauphin 2 helicopter
NASA Astrophysics Data System (ADS)
Newman, J. S.; Rickely, E. J.; Daboin, S. A.; Beattie, K. R.
1984-04-01
This report documents the results of a Federal Aviation Administration (FAA) noise measurement flight test program with the Dauphin twin-jet helicopter. The report contains documentary sections describing the acoustical characteristics of the subject helicopter and provides analyses and discussions addressing topics ranging from acoustical propagation to environmental impact of helicopter noise. This report is the second in a series of seven documenting the FAA helicopter noise measurement program conducted at Dulles International Airport during the summer of 1983. The Dauphin test program involved the acquisition of detailed acoustical, position and meteorological data. This test program was designed to address a series of objectives including: (1) acquisition of acoustical data for use in assessing heliport environment impact, (2) documentation of directivity characteristics for static operation of helicopters, (3) establishment of ground-to-ground and air-to-ground acoustical propagation relationships for helicopters, (4) determination of noise event duration influences on energy dose acoustical metrics, (5) examination of the differences between noise measured by a surface mounted microphone and a microphone mounted at a height of four feet (1.2 meters), and (6) documentation of noise levels acquired using international helicopter noise certification test procedures.
NASA Astrophysics Data System (ADS)
Oh, Himchan; Pi, Jae-Eun; Hwang, Chi-Sun; Kwon, Oh-Sang
2017-12-01
Self-aligned gate structures are preferred for faster operation and scaling down of thin film transistors by reducing the overlapped region between source/drain and gate electrodes. Doping on source/drain regions is essential to fabricate such a self-aligned gate thin film transistor. For oxide semiconductors such as In-Ga-Zn-O, SiNx capping readily increases their carrier concentration. We report that the SiNx deposition temperature and thickness significantly affect the device properties, including threshold voltage, field effect mobility, and contact resistance. The reason for these variations in device characteristics mainly comes from the extension of the doped region to the gated area after the SiNx capping step. Analyses on capacitance-voltage and transfer length characteristics support this idea.
A pulsed load model and its impact on a synchronous-rectifier system
NASA Astrophysics Data System (ADS)
Hou, Pengfei; Xu, Ye; Li, Jianke; Wang, Jinquan; Zhang, Haitao; Yan, Jun; Wang, Chunming; Chen, Jingjing
2017-02-01
The pulsed load has become a developing trend of power loading. Unlike traditional loads, pulsed loads with current abrupt and repeated charges will result in unstable Microgrid operations because of their small capacity and inertia. In this paper, an Average Magnitude Sum Function (AMSF) is proposed to calculate the frequency of the grid, and based on AMSF, the Relative Deviation Rate (RDR) that characterises the impact of pulsed load on the AC side of the grid is defined and its calculation process is described in detail. In addition, the system dynamic characteristics under a pulsed load are analysed using an Insulated Gate Bipolar Transistor (IGBT) to control the on/off state of the resistive load for simulating a pulsed load. Finally, the transient characteristics of a synchronous-rectifier system with a pulsed load are studied and validated experimentally.
Enzymatic AND logic gates operated under conditions characteristic of biomedical applications.
Melnikov, Dmitriy; Strack, Guinevere; Zhou, Jian; Windmiller, Joshua Ray; Halámek, Jan; Bocharova, Vera; Chuang, Min-Chieh; Santhosh, Padmanabhan; Privman, Vladimir; Wang, Joseph; Katz, Evgeny
2010-09-23
Experimental and theoretical analyses of the lactate dehydrogenase and glutathione reductase based enzymatic AND logic gates in which the enzymes and their substrates serve as logic inputs are performed. These two systems are examples of the novel, previously unexplored class of biochemical logic gates that illustrate potential biomedical applications of biochemical logic. They are characterized by input concentrations at logic 0 and 1 states corresponding to normal and pathophysiological conditions. Our analysis shows that the logic gates under investigation have similar noise characteristics. Both significantly amplify random noise present in inputs; however, we establish that for realistic widths of the input noise distributions, it is still possible to differentiate between the logic 0 and 1 states of the output. This indicates that reliable detection of pathophysiological conditions is indeed possible with such enzyme logic systems.
Martínez-Camblor, Pablo; Pardo-Fernández, Juan C
2017-01-01
Diagnostic procedures are based on establishing certain conditions and then checking if those conditions are satisfied by a given individual. When the diagnostic procedure is based on a continuous marker, this is equivalent to fix a region or classification subset and then check if the observed value of the marker belongs to that region. Receiver operating characteristic curve is a valuable and popular tool to study and compare the diagnostic ability of a given marker. Besides, the area under the receiver operating characteristic curve is frequently used as an index of the global discrimination ability. This paper revises and widens the scope of the receiver operating characteristic curve definition by setting the classification subsets in which the final decision is based in the spotlight of the analysis. We revise the definition of the receiver operating characteristic curve in terms of particular classes of classification subsets and then focus on a receiver operating characteristic curve generalization for situations in which both low and high values of the marker are associated with more probability of having the studied characteristic. Parametric and non-parametric estimators of the receiver operating characteristic curve generalization are investigated. Monte Carlo studies and real data examples illustrate their practical performance.
Mazmudar, Aditya; Vitello, Dominic; Chapman, Mackenzie; Tomlinson, James S; Bentrem, David J
2017-02-01
Patient selection remains paramount when developing and adopting quality-based assessment and reimbursement models, and enhanced recovery protocols. Gender is a patient characteristic known before surgery which can inform risk stratification. Our aim was to evaluate the effect of gender on intraoperative blood transfusions, operative time, length of hospital stay, estimated blood loss (EBL) as well as postoperative surgical site infections (SSIs), and mortality. Patients undergoing elective pancreatectomy from 2005 to 2013 were identified in the American College of Surgeons National Surgical Quality Improvement Program (ACS-NSQIP) and Northwestern institutional databases. Multivariable analyses were conducted to identify the association between gender and these outcomes. Analyses demonstrated that male gender was independently associated with blood transfusion (OR 1.23), operative time >6 hr (OR 1.76), length of stay greater than 11 days (OR 1.17), and all-type SSIs (OR 1.17), especially superficial SSIs (OR 1.15) and organ space SSIs (OR 1.18). Analysis of the institutional cohort found that male gender was independently associated with increased odds of EBL > 1 L for Whipple procedures (OR 2.85). Male gender is a significant predictor of increased operative time, length of stay, transfusions, EBL > 1L, as well as postoperative organ space surgical site infections in these patients. J. Surg. Oncol. 2017;115:131-136. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
White, M.A.; Schmidt, J.C.; Topping, D.J.
2005-01-01
Wavelet analysis is a powerful tool with which to analyse the hydrologic effects of dam construction and operation on river systems. Using continuous records of instantaneous discharge from the Lees Ferry gauging station and records of daily mean discharge from upstream tributaries, we conducted wavelet analyses of the hydrologic structure of the Colorado River in Grand Canyon. The wavelet power spectrum (WPS) of daily mean discharge provided a highly compressed and integrative picture of the post-dam elimination of pronounced annual and sub-annual flow features. The WPS of the continuous record showed the influence of diurnal and weekly power generation cycles, shifts in discharge management, and the 1996 experimental flood in the post-dam period. Normalization of the WPS by local wavelet spectra revealed the fine structure of modulation in discharge scale and amplitude and provides an extremely efficient tool with which to assess the relationships among hydrologic cycles and ecological and geomorphic systems. We extended our analysis to sections of the Snake River and showed how wavelet analysis can be used as a data mining technique. The wavelet approach is an especially promising tool with which to assess dam operation in less well-studied regions and to evaluate management attempts to reconstruct desired flow characteristics. Copyright ?? 2005 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Zhao, Yingru; Chen, Jincan
A theoretical modeling approach is presented, which describes the behavior of a typical fuel cell-heat engine hybrid system in steady-state operating condition based on an existing solid oxide fuel cell model, to provide useful fundamental design characteristics as well as potential critical problems. The different sources of irreversible losses, such as the electrochemical reaction, electric resistances, finite-rate heat transfer between the fuel cell and the heat engine, and heat-leak from the fuel cell to the environment are specified and investigated. Energy and entropy analyses are used to indicate the multi-irreversible losses and to assess the work potentials of the hybrid system. Expressions for the power output and efficiency of the hybrid system are derived and the performance characteristics of the system are presented and discussed in detail. The effects of the design parameters and operating conditions on the system performance are studied numerically. It is found that there exist certain optimum criteria for some important parameters. The results obtained here may provide a theoretical basis for both the optimal design and operation of real fuel cell-heat engine hybrid systems. This new approach can be easily extended to other fuel cell hybrid systems to develop irreversible models suitable for the investigation and optimization of similar energy conversion settings and electrochemistry systems.
Characterisation of an urban bus network for environmental purposes.
André, Michel; Villanova, André
2004-12-01
Since pollutant emissions are closely related to the operating conditions of vehicles, their evaluation usually involves studying these operating conditions (through bus instrumentation and monitoring under actual operation), the design of representative driving or engine test cycles and the measurement of pollutant emissions. A preliminary characterisation of the routes on a bus network should make it possible to identify typical routes, the driving conditions and pollutant emissions of which are then studied. Two approaches are envisaged and applied to the Paris area, for which a wealth of information is available, which should be transferable to other bus networks. Both approaches are based on factorial analysis and automatic clustering, to allow optimum description and the identification of a pertinent typology of the bus routes in several classes. The first attempt at characterisation is based on statistics relating to bus operations: route characteristics (length, dedicated bus lanes, number of stops, location of stops: schools, tourist sites, hospitals, railways or underground stations), travel time, commercial speed, annual statistics (number of passengers, number of vehicles per hour, total kilometres), the irregularity of travel (variation of travel times, injuries, congestion.), as well as information on the problems encountered (congestion, distribution of the passenger load, junctions, bends). A second approach is based on the analysis of the "urban context" in which buses are driven. Population, employment, housing, road network, traffic and places that generate or disturb traffic (schools, railway stations, shopping areas, etc.) are calculated for the Ile de France region, by cells of 100 x 100 m, and collected in a geographical information system (GIS). Statistical analyses enable a typology of these urban cells to be established, the main parameters being density, type of housing, road types and traffic levels. The bus routes are then analysed according to their itineraries across these typical areas (distances travelled in each type of area) using a similar approach. A comparison of the typologies obtained from operational data and from urban data highlights the advantages and disadvantages of the two approaches. The first result from these typologies is the selection of routes which are representative of the different classes, in order to instrument buses and record driving patterns. This method should also make it possible to link driving conditions and urban characteristics, and then to allocate pollutant emission factors to given geographical situations, in particular, in the context of emission inventories or impact studies.
Physiology limits commercially viable photoautotrophic production of microalgal biofuels.
Kenny, Philip; Flynn, Kevin J
2017-01-01
Algal biofuels have been offered as an alternative to fossil fuels, based on claims that microalgae can provide a highly productive source of compounds as feedstocks for sustainable transport fuels. Life cycle analyses identify algal productivity as a critical factor affecting commercial and environmental viability. Here, we use mechanistic modelling of the biological processes driving microalgal growth to explore optimal production scenarios in an industrial setting, enabling us to quantify limits to algal biofuels potential. We demonstrate how physiological and operational trade-offs combine to restrict the potential for solar-powered algal-biodiesel production in open ponds to a ceiling of ca. 8000 L ha -1 year -1 . For industrial-scale operations, practical considerations limit production to ca. 6000 L ha -1 year -1 . According to published economic models and life cycle analyses, such production rates cannot support long-term viable commercialisation of solar-powered cultivation of natural microalgae strains exclusively as feedstock for biofuels. The commercial viability of microalgal biofuels depends critically upon limitations in microalgal physiology (primarily in rates of C-fixation); we discuss the scope for addressing this bottleneck concluding that even deployment of genetically modified microalgae with radically enhanced characteristics would leave a very significant logistical if not financial burden.
Migration of the Duraloc cup after 5 years
Stihsen, Christoph; Pabinger, Christof; Radl, Roman; Rehak, Peter
2007-01-01
The Duraloc cup is a frequently used metal-backed, porous-coated, hemispherical, press-fit acetabular component. Published data on loosening rates are contradictory. In this study we investigated migration patterns with computer-assisted Einzel-Bild-Roentgen-Analyse (EBRA) of 67 Duraloc 100 cups. Cup migration and clinical scores were analysed over a 5-year follow-up period. Median total migration of the Duraloc 100 cup was 1.21 mm at 5 years. Seventy-five percent of implants were radiologically stable at 2 years and 90% at 4 years. One cup loosened aseptically at 60 months, requiring revision. Cup diameters ≥54 mm migrated significantly more than cups <54 mm in diameter (p = 0.029 at 4 years). There was a significant correlation between high polyethylene wear and further migrating cups within the first post-operative year (p = 0.035 at 12 months). Our analysis revealed significantly higher wear in males (p = 0.029 at 4 years). Radiological loosening at two years could be calculated using receiver-operating characteristic curve analysis, and 1.2 mm as an adequate threshold value (sensitivity = 100%, specificity = 89%). PMID:17609953
Evaluation of Advanced Solid Lubricant Coatings for Foil Air Bearings Operating at 25 and 500 C
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher; Fellenstein, James A.; Benoy, Patricia A.
1998-01-01
The tribological properties of one chrome oxide and one chrome carbide based solid lubricant coating were evaluated in a partial-arc foil bearing at 25 and 500 C. Start/stop bearing operation up to 20,000 cycles were run under 10 kPa (1.5 psi) static deadweight load. Bearing friction (torque) was measured during the test. Specimen wear and SEM/EDS surface analyses were conducted after testing to understand and elucidate the tribological characteristics observed. The chrome oxide coating which contains both (Ag) and (BaF2/CaF2) for low and high temperature lubrication, exhibited low friction in sliding against Al2O3 coated foils at 25 and 500 C. The chrome carbide coating, which lacked a low temperature lubricant but contained BaF2/CaF2 as a high temperature lubricant, exhibited high friction at 25 C and low friction at 500 C against both bare and Al2O3 coated superalloy foil surfaces. Post test surface analyses suggest that improved tribological performance is exhibited when a lubricant film from the coating transfers to the foil surface.
Ranucci, Marco; Castelvecchio, Serenella; Menicanti, Lorenzo; Frigiola, Alessandro; Pelissero, Gabriele
2010-03-01
The European system for cardiac operative risk evaluation (EuroSCORE) is currently used in many institutions and is considered a reference tool in many countries. We hypothesised that too many variables were included in the EuroSCORE using limited patient series. We tested different models using a limited number of variables. A total of 11150 adult patients undergoing cardiac operations at our institution (2001-2007) were retrospectively analysed. The 17 risk factors composing the EuroSCORE were separately analysed and ranked for accuracy of prediction of hospital mortality. Seventeen models were created by progressively including one factor at a time. The models were compared for accuracy with a receiver operating characteristics (ROC) analysis and area under the curve (AUC) evaluation. Calibration was tested with Hosmer-Lemeshow statistics. Clinical performance was assessed by comparing the predicted with the observed mortality rates. The best accuracy (AUC 0.76) was obtained using a model including only age, left ventricular ejection fraction, serum creatinine, emergency operation and non-isolated coronary operation. The EuroSCORE AUC (0.75) was not significantly different. Calibration and clinical performance were better in the five-factor model than in the EuroSCORE. Only in high-risk patients were 12 factors needed to achieve a good performance. Including many factors in multivariable logistic models increases the risk for overfitting, multicollinearity and human error. A five-factor model offers the same level of accuracy but demonstrated better calibration and clinical performance. Models with a limited number of factors may work better than complex models when applied to a limited number of patients. Copyright (c) 2009 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.
CMG-biotools, a free workbench for basic comparative microbial genomics.
Vesth, Tammi; Lagesen, Karin; Acar, Öncel; Ussery, David
2013-01-01
Today, there are more than a hundred times as many sequenced prokaryotic genomes than were present in the year 2000. The economical sequencing of genomic DNA has facilitated a whole new approach to microbial genomics. The real power of genomics is manifested through comparative genomics that can reveal strain specific characteristics, diversity within species and many other aspects. However, comparative genomics is a field not easily entered into by scientists with few computational skills. The CMG-biotools package is designed for microbiologists with limited knowledge of computational analysis and can be used to perform a number of analyses and comparisons of genomic data. The CMG-biotools system presents a stand-alone interface for comparative microbial genomics. The package is a customized operating system, based on Xubuntu 10.10, available through the open source Ubuntu project. The system can be installed on a virtual computer, allowing the user to run the system alongside any other operating system. Source codes for all programs are provided under GNU license, which makes it possible to transfer the programs to other systems if so desired. We here demonstrate the package by comparing and analyzing the diversity within the class Negativicutes, represented by 31 genomes including 10 genera. The analyses include 16S rRNA phylogeny, basic DNA and codon statistics, proteome comparisons using BLAST and graphical analyses of DNA structures. This paper shows the strength and diverse use of the CMG-biotools system. The system can be installed on a vide range of host operating systems and utilizes as much of the host computer as desired. It allows the user to compare multiple genomes, from various sources using standardized data formats and intuitive visualizations of results. The examples presented here clearly shows that users with limited computational experience can perform complicated analysis without much training.
Computer aided analysis, simulation and optimisation of thermal sterilisation processes.
Narayanan, C M; Banerjee, Arindam
2013-04-01
Although thermal sterilisation is a widely employed industrial process, little work is reported in the available literature including patents on the mathematical analysis and simulation of these processes. In the present work, software packages have been developed for computer aided optimum design of thermal sterilisation processes. Systems involving steam sparging, jacketed heating/cooling, helical coils submerged in agitated vessels and systems that employ external heat exchangers (double pipe, shell and tube and plate exchangers) have been considered. Both batch and continuous operations have been analysed and simulated. The dependence of del factor on system / operating parameters such as mass or volume of substrate to be sterilised per batch, speed of agitation, helix diameter, substrate to steam ratio, rate of substrate circulation through heat exchanger and that through holding tube have been analysed separately for each mode of sterilisation. Axial dispersion in the holding tube has also been adequately accounted for through an appropriately defined axial dispersion coefficient. The effect of exchanger characteristics/specifications on the system performance has also been analysed. The multiparameter computer aided design (CAD) software packages prepared are thus highly versatile in nature and they permit to make the most optimum choice of operating variables for the processes selected. The computed results have been compared with extensive data collected from a number of industries (distilleries, food processing and pharmaceutical industries) and pilot plants and satisfactory agreement has been observed between the two, thereby ascertaining the accuracy of the CAD softwares developed. No simplifying assumptions have been made during the analysis and the design of associated heating / cooling equipment has been performed utilising the most updated design correlations and computer softwares.
Carbon Deposition Model for Oxygen-Hydrocarbon Combustion, Volume 2
NASA Technical Reports Server (NTRS)
Hernandez, R.; Ito, J. I.; Niiya, K. Y.
1987-01-01
Presented are details of the design, fabrication, and testing of subscale hardware used in the evaluation of carbon deposition characteristics of liquid oxygen and three hydrocarbon fuels for both main chamber and preburner/gas generator operating conditions. In main chamber conditions, the deposition of carbon on the combustion chamber wall was investigated at mixture ratios of 2.0 to 4.0 and at chamber pressures of 1000 to 1500 psia. No carbon deposition on chamber walls was detected at these main chamber mixture ratios. In preburner/gas generator operating conditions, the deposition of carbon on the turbine simulator tubes was evaluated at mixture ratios of 0.20 to 0.60 and at chamber pressures of 720 to 1650 psia. The results of the tests showed carbon deposition rate to be a strong function of mixture ratio and a weak function of chamber pressure. Further analyses evaluated the operational concequences of carbon deposition on preburner/gas generator performance. This is Volume 2 of the report, which contains data plots of all the test programs.
Using game technologies to improve the safety of construction plant operations.
Guo, Hongling; Li, Heng; Chan, Greg; Skitmore, Martin
2012-09-01
Many accidents occur world-wide in the use of construction plant and equipment, and safety training is considered by many to be one of the best approaches to their prevention. However, current safety training methods/tools are unable to provide trainees with the hands-on practice needed. Game technology-based safety training platforms have the potential to overcome this problem in a virtual environment. One such platform is described in this paper - its characteristics are analysed and its possible contribution to safety training identified. This is developed and tested by means of a case study involving three major pieces of construction plant, which successfully demonstrates that the platform can improve the process and performance of the safety training involved in their operation. This research not only presents a new and useful solution to the safety training of construction operations, but illustrates the potential use of advanced technologies in solving construction industry problems in general. Copyright © 2011 Elsevier Ltd. All rights reserved.
Suicide rates in European OECD nations converged during the period 1990-2010.
Bremberg, Sven G
2017-05-01
The aim of this study was to investigate, with multiple regression analyses, the effect of selected characteristics on the rate of decrease of suicide rates in 21 OECD (Organisation for Economic Co-operation and Development) nations over the period 1990-2010, with initial levels of suicide rates taken into account. The rate of decrease seems mainly (83%) to be determined by the initial suicide rates in 1990. In nations with relatively high initial rates, the rates decreased faster. The suicide rates also converged. The study indicates that beta convergence alone explained most of the cross-national variations.
En route noise of two turboprop aircraft
NASA Technical Reports Server (NTRS)
Dobrzynski, Werner
1990-01-01
In order to weigh en route noise emissions originating from future propfan powered aircraft, a data base of emission levels from conventional turboprop aircraft is needed. For this reason flyover noise measurements on two twin-engine turboprop aircraft were conducted at flight heights between 17,000 and 21,000 ft. Acoustic data are presented together with propeller operational parameters and environmental meteorological data. Narrowband spectral analyses demonstrate the characteristic features of the measured propeller noise signatures: Noise spectra are dominated by the propeller rotational noise fundamental frequency and pronounced noise beats occur as a consequence of different rotational speeds of the propellers.
Laser beam machining of polycrystalline diamond for cutting tool manufacturing
NASA Astrophysics Data System (ADS)
Wyszyński, Dominik; Ostrowski, Robert; Zwolak, Marek; Bryk, Witold
2017-10-01
The paper concerns application of DPSS Nd: YAG 532nm pulse laser source for machining of polycrystalline WC based diamond inserts (PCD). The goal of the research was to determine optimal laser cutting parameters for cutting tool shaping. Basic criteria to reach the goal was cutting edge quality (minimalization of finishing operations), material removal rate (time and cost efficiency), choice of laser beam characteristics (polarization, power, focused beam diameter). The research was planned and realised and analysed according to design of experiment rules (DOE). The analysis of the cutting edge was prepared with use of Alicona Infinite Focus measurement system.
Spectral linewidth of spin-current nano-oscillators driven by nonlocal spin injection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demidov, V. E., E-mail: demidov@uni-muenster.de; Divinskiy, B.; Urazhdin, S.
2015-11-16
We study experimentally the auto-oscillation characteristics of magnetic nano-oscillators driven by pure spin currents generated by nonlocal spin injection. By combining micro-focus Brillouin light scattering spectroscopy with electronic microwave spectroscopy, we are able to simultaneously perform both the spatial and the high-resolution spectral analyses of auto-oscillations induced by spin current. We find that the devices exhibit a highly coherent dynamics with the spectral linewidth of a few megahertz at room temperature. This narrow linewidth can be achieved over a wide range of operational frequencies, demonstrating a significant potential of nonlocal oscillators for applications.
A Simple and Robust Method for Partially Matched Samples Using the P-Values Pooling Approach
Kuan, Pei Fen; Huang, Bo
2013-01-01
This paper focuses on statistical analyses in scenarios where some samples from the matched pairs design are missing, resulting in partially matched samples. Motivated by the idea of meta-analysis, we recast the partially matched samples as coming from two experimental designs, and propose a simple yet robust approach based on the weighted Z-test to integrate the p-values computed from these two designs. We show that the proposed approach achieves better operating characteristics in simulations and a case study, compared to existing methods for partially matched samples. PMID:23417968
Mechanical behaviour of cerclage material consisting of silicon rubber.
Hinrichsen, G; Eberhardt, A; Springer, H
1979-09-01
Silicon rubber specimens of circular or rectangular cross-section (cross-section area between ca. 2 and 7 mm2) are used as cerclage bands. A series of commercial cerclage elements was investigated for mechanical characteristics, such as stress-strain behaviour and modulus of elasticity, using a tensile-testing machine. Large differences in these properties exist among the various specimens. Moreover, time-dependent effects, such as stress-relaxation, retardation, and creep, were analysed by the present investigations. One has to take into consideration that the initial length and stress of the cerclage band vary significantly with time after the operation.
Efficacy of a telerehabilitation intervention programme using biofeedback among computer operators.
Golebowicz, Merav; Levanon, Yafa; Palti, Ram; Ratzon, Navah Z
2015-01-01
Computer operators spend long periods of time sitting in a static posture at computer workstations and therefore have an increased exposure to work-related musculoskeletal disorders (WRMSD). The present study is aimed at investigating the feasibility and effectiveness of a tele-biofeedback ergonomic intervention programme among computer operators suffering from WRMSD. Twelve subjects with WRMSD were assigned an ergonomic intervention accompanied by remote tele-biofeedback training, which was practised at their workstations. Evaluations of pain symptoms and locations, body posture and psychosocial characteristics were carried out before and after the intervention in the workplace. The hypothesis was partially verified as it showed improved body position at the workstation and decreased pain in some body parts. Tele-biofeedback, as part of an intervention, appears to be feasible and efficient for computer operators who suffer from WRMSD. This study encourages further research on tele-health within the scope of occupational therapy practice. Practitioner summary: Research concerning tele-health using biofeedback is scarce. The present study analyses the feasibility and partial effectiveness of a tele-biofeedback ergonomic intervention programme for computer operators suffering from WRMSD. The uniqueness and singularity of this study is the usage of remote communication between participants and practitioners through the Internet.
Safety illusion and error trap in a collectively-operated machine accident.
de Almeida, Ildeberto Muniz; Nobre, Hildeberto; do Amaral Dias, Maria Dionísia; Vilela, Rodolfo Andrade Gouveia
2012-01-01
Workplace accidents involving machines are relevant for their magnitude and their impacts on worker health. Despite consolidated critical statements, explanation centered on errors of operators remains predominant with industry professionals, hampering preventive measures and the improvement of production-system reliability. Several initiatives were adopted by enforcement agencies in partnership with universities to stimulate production and diffusion of analysis methodologies with a systemic approach. Starting from one accident case that occurred with a worker who operated a brake-clutch type mechanical press, the article explores cognitive aspects and the existence of traps in the operation of this machine. It deals with a large-sized press that, despite being endowed with a light curtain in areas of access to the pressing zone, did not meet legal requirements. The safety devices gave rise to an illusion of safety, permitting activation of the machine when a worker was still found within the operational zone. Preventive interventions must stimulate the tailoring of systems to the characteristics of workers, minimizing the creation of traps and encouraging safety policies and practices that replace judgments of behaviors that participate in accidents by analyses of reasons that lead workers to act in that manner.
[Rectovaginal endometriosis--analysis of 160 cases].
Wilczyński, Miłosz; Wiecka-Płusa, Monika; Antosiak, Beata; Maciołek-Blewniewska, Grazyna; Majchrzak-Baczmańska, Dominika; Malinowski, Andrzej
2015-12-01
The aim of the study was a retrospective analysis of the medical records of patients who underwent surgery due to deep infiltrating rectovaginal endometriosis (mainly with the use of the 'shaving' technique). We analysed 160 cases of patients who underwent surgery due to the deep infiltrating rectovaginal endometriosis in our ward between 2003-2014. Depending on lesion localization, disease severity and clinical characteristics, three possible ways of operation were proposed: laparoscopic, vaginal or a combined vagino-laparoscopic approach. A total of 120 patients underwent laparoscopic removal of the endometrial lesions, whereas 17 were operated vaginally and 23 with the use of the combined approach. Nodule resection was successfully performed in all cases. The combined vagino-laparoscopic operations were characterized by the longest operating time. The rate of perioperative complications was low in the group of patients who underwent laparoscopic or combined operations. The necessity of bowel wall suturing occurred in 15 cases. This procedure was performed in order to strengthen the bowel wall (in cases when no perforation occurred) or due to bowel resection during surgery. Unexpected bowel perforation occurred in only 5 cases. Conclusions: Vaginal, laparoscopic and the combined vagino-laparoscopic surgeries can be safely performed in cases of deep rectovaginal endometriosis.
Truck characteristics for use in highway design and operation. Volume II, Appendices
DOT National Transportation Integrated Search
1990-08-01
Highway geometric design and traffic operations are based in part on consideration of vehicle characteristics. However, many of the current highway design and operational criteria are based on passenger car characteristics, even though truck characte...
49 CFR 236.717 - Characteristics, operating.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Characteristics, operating. 236.717 Section 236.717 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 236.717 Characteristics, operating. The measure of electrical values at which electrical or electronic...
49 CFR 236.717 - Characteristics, operating.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Characteristics, operating. 236.717 Section 236.717 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... § 236.717 Characteristics, operating. The measure of electrical values at which electrical or electronic...
Monitoring Effective Doses Received By Air Crews With A Space Weather Application
NASA Astrophysics Data System (ADS)
Lantos, P.
To fulfil new requirements of the European Community concerning monitoring of effective doses received by air crews, the French Aviation Authority has developed an operational system called Sievert. The SIEVERT system is analysed as an exam- ple of Space Weather application. One of its characteristics is to calculate the dose received on-board each flight on the basis of the specific and detailled flight given by companies. Operational models will be used. As input to the models, the system needs monitoring of galactic cosmic rays and of solar flare particles. The French neu- tron monitors located in Kerguelen Islands (South Indian Ocean) and Terre Adélie (Antarctica) will be used for this purpose. Particular attention will be devoted to evo- lution of the system in conjunction with new measurements available in the frame of a permanent validation process.
NASA Technical Reports Server (NTRS)
Burge, G. W.; Blackmon, J. B.
1973-01-01
Areas of cryogenic fuel systems were identified where critical experimental information was needed either to define a design criteria or to establish the feasibility of a design concept or a critical aspect of a particular design. Such data requirements fell into three broad categories: (1) basic surface tension screen characteristics; (2) screen acquisition device fabrication problems; and (3) screen surface tension device operational failure modes. To explore these problems and to establish design criteria where possible, extensive laboratory or bench test scale experiments were conducted. In general, these proved to be quite successful and, in many instances, the test results were directly used in the system design analyses and development. In some cases, particularly those relating to operational-type problems, areas requiring future research were identified, especially screen heat transfer and vibrational effects.
NASA - easyJet Collaboration on the Human Factors Monitoring Program (HFMP) Study
NASA Technical Reports Server (NTRS)
Srivistava, Ashok N.; Barton, Phil
2012-01-01
This is the first annual report jointly prepared by NASA and easyJet on the work performed under the agreement to collaborate on a study of the many factors entailed in flight - and cabin-crew fatigue and documenting the decreases in performance associated with fatigue. The objective of this Agreement is to generate reliable, automated procedures that improve understanding of the levels and characteristics of flight - and cabin-crew fatigue factors, both latent and proximate, whose confluence will likely result in unacceptable flight crew performance. This study entails the analyses of numerical and textual data collected during operational flights. NASA and easyJet are both interested in assessing and testing NASA s automated capabilities for extracting operationally significant information from very large, diverse (textual and numerical) databases, much larger than can be handled practically by human experts.
NASA Technical Reports Server (NTRS)
Srivistava, Ashok N.; Barton, Phil
2012-01-01
This is the second interim report jointly prepared by NASA and easyJet on the work performed under the agreement to collaborate on a study of the factors entailed in flight and cabin-crew fatigue, and decreases in performance associated with fatigue. The objective of this Agreement is to generate reliable procedures that aid in understanding the levels and characteristics of flight and cabin-crew fatigue factors, both latent and proximate, whose confluence will likely result in unacceptable crew performance. This study entails the analyses of numerical and textual data collected during operational flights. NASA and easyJet are both interested in assessing and testing NASA s automated capabilities for extracting operationally significant information from very large, diverse (textual and numerical) databases; much larger than can be handled practically by human experts.
Grassineau, N V; Nisbet, E G; Bickle, M J; Fowler, C M; Lowry, D; Mattey, D P; Abell, P; Martin, A
2001-01-01
Sulphur and carbon isotopic analyses on small samples of kerogens and sulphide minerals from biogenic and non-biogenic sediments of the 2.7 x 10(9) years(Ga)-old Belingwe Greenstone Belt (Zimbabwe) imply that a complex biological sulphur cycle was in operation. Sulphur isotopic compositions display a wider range of biological fractionation than hitherto reported from the Archaean. Carbon isotopic values in kerogen record fractionations characteristic of rubisco activity methanogenesis and methylotrophy and possibly anoxygenic photosynthesis. Carbon and sulphur isotopic fractionations have been interpreted in terms of metabolic processes in 2.7 Ga prokaryote mat communities, and indicate the operation of a diverse array of metabolic processes. The results are consistent with models of early molecular evolution derived from ribosomal RNA. PMID:11209879
The performance of material management in health care organizations.
Dacosta-Claro, Ivan
2002-01-01
This paper studies the hospital supply chain. The analysis of the operational and financial data of hospital administrative structures has permitted the discovery of the characteristics of work carried out by the employees and the different strategies used by the managers. Firstly, hospital supply chains must be classified into two groups influenced by medical factors (short-term and long-term hospitals). Secondly, two different management approaches can be observed when the supply chain operations are analysed. The first approach assigns a larger budget priority to inventory control, packages reception and internal distribution. Thus, the purchasing services have relatively fewer resources. In the second approach, contract negotiation and product ordering processes are enforced by the deployment of, relatively, more personnel. In both cases, the central store service performs merchandise reception and distribution according to the strategies determined by the purchasing service.
Evans, Kris; Rotello, Caren M.; Li, Xingshan; Rayner, Keith
2009-01-01
Cultural differences have been observed in scene perception and memory: Chinese participants purportedly attend to the background information more than did American participants. We investigated the influence of culture by recording eye movements during scene perception and while participants made recognition memory judgements. Real-world pictures with a focal object on a background were shown to both American and Chinese participants while their eye movements were recorded. Later, memory for the focal object in each scene was tested, and the relationship between the focal object (studied, new) and the background context (studied, new) was manipulated. Receiver-operating characteristic (ROC) curves show that both sensitivity and response bias were changed when objects were tested in new contexts. However, neither the decrease in accuracy nor the response bias shift differed with culture. The eye movement patterns were also similar across cultural groups. Both groups made longer and more fixations on the focal objects than on the contexts. The similarity of eye movement patterns and recognition memory behaviour suggests that both Americans and Chinese use the same strategies in scene perception and memory. PMID:18785074
Human movement analysis with image processing in real time
NASA Astrophysics Data System (ADS)
Fauvet, Eric; Paindavoine, Michel; Cannard, F.
1991-04-01
In the field of the human sciences, a lot of applications needs to know the kinematic characteristics of the human movements Psycology is associating the characteristics with the control mechanism, sport and biomechariics are associating them with the performance of the sportman or of the patient. So the trainers or the doctors can correct the gesture of the subject to obtain a better performance if he knows the motion properties. Roherton's studies show the children motion evolution2 . Several investigations methods are able to measure the human movement But now most of the studies are based on image processing. Often the systems are working at the T.V. standard (50 frame per secund ). they permit only to study very slow gesture. A human operator analyses the digitizing sequence of the film manually giving a very expensive, especially long and unprecise operation. On these different grounds many human movement analysis systems were implemented. They consist of: - markers which are fixed to the anatomical interesting points on the subject in motion, - Image compression which is the art to coding picture data. Generally the compression Is limited to the centroid coordinates calculation tor each marker. These systems differ from one other in image acquisition and markers detection.
Pati, Sumati; Maity, A; Banerji, P; Majumder, S B
2014-04-07
In the present work we have grown highly textured, ultra-thin, nano-crystalline zinc oxide thin films using a metal organic chemical vapor deposition technique and addressed their selectivity towards hydrogen, carbon dioxide and methane gas sensing. Structural and microstructural characteristics of the synthesized films were investigated utilizing X-ray diffraction and electron microscopy techniques respectively. Using a dynamic flow gas sensing measurement set up, the sensing characteristics of these films were investigated as a function of gas concentration (10-1660 ppm) and operating temperature (250-380 °C). ZnO thin film sensing elements were found to be sensitive to all of these gases. Thus at a sensor operating temperature of ~300 °C, the response% of the ZnO thin films were ~68, 59, and 52% for hydrogen, carbon monoxide and methane gases respectively. The data matrices extracted from first Fourier transform analyses (FFT) of the conductance transients were used as input parameters in a linear unsupervised principal component analysis (PCA) pattern recognition technique. We have demonstrated that FFT combined with PCA is an excellent tool for the differentiation of these reducing gases.
Naito, Masahito; Yamamoto, Tomoya; Shimamoto, Chikao; Miwa, Yoshihiro
2017-01-01
Previous Japanese trials of the docetaxel, cisplatin, and 5-fluorouracil regimen for oesophageal cancer have demonstrated that a large proportion of patients also develop grade IV neutropenia. Our aim was to examine the risk factors for neutropenia in patients treated with this regimen. We retrospectively analysed the risk factors for developing grade IV neutropenia in 66 patients with oesophageal cancer using a multivariate analysis. After administering the docetaxel, cisplatin, and 5-fluorouracil regimen, 49 patients (74.2%) developed grade IV neutropenia. Grade IV neutropenia was significantly associated with platelet count (p < 0.01), alanine transaminase level (p = 0.05), and proton-pump inhibitor administration (p < 0.05). Receiver operating characteristic curve analysis confirmed a platelet count of 290 × 103/μL as the optimal diagnostic cut-off value for grade IV neutropenia. The receiver operating characteristic area for grade IV neutropenia was increased by including patients that were administered a proton-pump inhibitor and alanine transaminase level (updated model; sensitivity and specificity, 75.5 and 88.2%, respectively). Our findings suggest that a platelet count is the most significant predictor of grade IV neutropenia. © 2017 S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brunett, A. J.; Fei, T.; Strons, P. S.
The Transient Reactor Test Facility (TREAT), located at Idaho National Laboratory (INL), is a test facility designed to evaluate the performance of reactor fuels and materials under transient accident conditions. The facility, an air-cooled, graphite-moderated reactor designed to utilize fuel containing high-enriched uranium (HEU), has been in non-operational standby status since 1994. Currently, in support of the missions of the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Material Management and Minimization (M3) Reactor Conversion Program, a new core design is being developed for TREAT that will utilize low-enriched uranium (LEU). The primary objective of this conversion effort ismore » to design an LEU core that is capable of meeting the performance characteristics of the existing HEU core. Minimal, if any, changes are anticipated for the supporting systems (e.g. reactor trip system, filtration/cooling system, etc.); therefore, the LEU core must also be able to function with the existing supporting systems, and must also satisfy acceptable safety limits. In support of the LEU conversion effort, a range of ancillary safety analyses are required to evaluate the LEU core operation relative to that of the existing facility. These analyses cover neutronics, shielding, and thermal hydraulic topics that have been identified as having the potential to have reduced safety margins due to conversion to LEU fuel, or are required to support the required safety analyses documentation. The majority of these ancillary tasks have been identified in [1] and [2]. The purpose of this report is to document the ancillary safety analyses that have been performed at Argonne National Laboratory during the early stages of the LEU design effort, and to describe ongoing and anticipated analyses. For all analyses presented in this report, methodologies are utilized that are consistent with, or improved from, those used in analyses for the HEU Final Safety Analysis Report (FSAR) [3]. Depending on the availability of historical data derived from HEU TREAT operation, results calculated for the LEU core are compared to measurements obtained from HEU TREAT operation. While all analyses in this report are largely considered complete and have been reviewed for technical content, it is important to note that all topics will be revisited once the LEU design approaches its final stages of maturity. For most safety significant issues, it is expected that the analyses presented here will be bounding, but additional calculations will be performed as necessary to support safety analyses and safety documentation. It should also be noted that these analyses were completed as the LEU design evolved, and therefore utilized different LEU reference designs. Preliminary shielding, neutronic, and thermal hydraulic analyses have been completed and have generally demonstrated that the various LEU core designs will satisfy existing safety limits and standards also satisfied by the existing HEU core. These analyses include the assessment of the dose rate in the hodoscope room, near a loaded fuel transfer cask, above the fuel storage area, and near the HEPA filters. The potential change in the concentration of tramp uranium and change in neutron flux reaching instrumentation has also been assessed. Safety-significant thermal hydraulic items addressed in this report include thermally-induced mechanical distortion of the grid plate, and heating in the radial reflector.« less
Jackknife variance of the partial area under the empirical receiver operating characteristic curve.
Bandos, Andriy I; Guo, Ben; Gur, David
2017-04-01
Receiver operating characteristic analysis provides an important methodology for assessing traditional (e.g., imaging technologies and clinical practices) and new (e.g., genomic studies, biomarker development) diagnostic problems. The area under the clinically/practically relevant part of the receiver operating characteristic curve (partial area or partial area under the receiver operating characteristic curve) is an important performance index summarizing diagnostic accuracy at multiple operating points (decision thresholds) that are relevant to actual clinical practice. A robust estimate of the partial area under the receiver operating characteristic curve is provided by the area under the corresponding part of the empirical receiver operating characteristic curve. We derive a closed-form expression for the jackknife variance of the partial area under the empirical receiver operating characteristic curve. Using the derived analytical expression, we investigate the differences between the jackknife variance and a conventional variance estimator. The relative properties in finite samples are demonstrated in a simulation study. The developed formula enables an easy way to estimate the variance of the empirical partial area under the receiver operating characteristic curve, thereby substantially reducing the computation burden, and provides important insight into the structure of the variability. We demonstrate that when compared with the conventional approach, the jackknife variance has substantially smaller bias, and leads to a more appropriate type I error rate of the Wald-type test. The use of the jackknife variance is illustrated in the analysis of a data set from a diagnostic imaging study.
Park, Jung-Keun
2016-12-01
Job hazard analyses were conducted to assess exposure to musculoskeletal disorder (MSD) risk factors in seven workers of three dry-cleaning establishments. In accordance with the Washington State Ergonomics Rule, the analyses were performed in two separate steps: (1) observation and checklist approaches were made to identify a "caution zone job" in the seven workers' pressing operations across the three shops; and (2) detailed posture and motion analyses were undertaken to determine a "MSD hazard" in one worker's operation using a video technique. One "caution zone job" was identified and it was the pressing operation job in which five physical risk factors were found in the pressing operations. The detailed analyses confirmed that one "MSD hazard", i.e., awkward posture in shoulders, was prevalent in the pressing operations of the three dry-cleaning facilities. It would be desirable to reduce MSD risk factors including awkward shoulder posture in the dry-cleaning industry.
Ramírez-Vélez, R; Correa-Bautista, J E; Martínez-Torres, J; Méneses-Echavez, J F; González-Ruiz, K; González-Jiménez, E; Schmidt-RioValle, J; Lobelo, F
2016-01-01
Background/Objectives: Indices predictive of central obesity include waist circumference (WC) and waist-to-height ratio (WHtR). These data are lacking for Colombian adults. This study aims at establishing smoothed centile charts and LMS tables for WC and WHtR; appropriate cutoffs were selected using receiver-operating characteristic analysis based on data from the representative sample. Subjects/Methods: We used data from the cross-sectional, national representative nutrition survey (ENSIN, 2010). A total of 83 220 participants (aged 20–64) were enroled. Weight, height, body mass index (BMI), WC and WHtR were measured and percentiles calculated using the LMS method (L (curve Box-Cox), M (curve median), and S (curve coefficient of variation)). Receiver operating characteristics curve analyses were used to evaluate the optimal cutoff point of WC and WHtR for overweight and obesity based on WHO definitions. Results: Reference values for WC and WHtR are presented. Mean WC and WHtR increased with age for both genders. We found a strong positive correlation between WC and BMI (r=0.847, P< 0.01) and WHtR and BMI (r=0.878, P<0.01). In obese men, the cutoff point value is 96.6 cm for the WC. In women, the cutoff point value is 91.0 cm for the WC. Receiver operating characteristic curve for WHtR was also obtained and the cutoff point value of 0.579 in men, and in women the cutoff point value was 0.587. A high sensitivity and specificity were obtained. Conclusions: This study presents first reference values of WC and WHtR for Colombians aged 20–64. Through LMS tables for adults, we hope to provide quantitative tools to study obesity and its complications. PMID:27026425
Diaphragm and Lung Ultrasound to Predict Weaning Outcome: Systematic Review and Meta-Analysis.
Llamas-Álvarez, Ana M; Tenza-Lozano, Eva M; Latour-Pérez, Jaime
2017-12-01
Deciding the optimal timing for extubation in patients who are mechanically ventilated can be challenging, and traditional weaning predictor tools are not very accurate. The aim of this systematic review and meta-analysis was to assess the accuracy of lung and diaphragm ultrasound for predicting weaning outcomes in critically ill adults. MEDLINE, the Cochrane Library, Web of Science, Scopus, LILACS, Teseo, Tesis Doctorales en Red, and OpenGrey were searched, and the bibliographies of relevant studies were reviewed. Two researchers independently selected studies that met the inclusion criteria and assessed study quality in accordance with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. The summary receiver-operating characteristic curve and pooled diagnostic OR (DOR) were estimated by using a bivariate random effects analysis. Sources of heterogeneity were explored by using predefined subgroup analyses and bivariate meta-regression. Nineteen studies involving 1,071 people were included in the study. For diaphragm thickening fraction, the area under the summary receiver-operating characteristic curve was 0.87, and DOR was 21 (95% CI, 11-40). Regarding diaphragmatic excursion, pooled sensitivity was 75% (95% CI, 65-85); pooled specificity, 75% (95% CI, 60-85); and DOR, 10 (95% CI, 4-24). For lung ultrasound, the area under the summary receiver-operating characteristic curve was 0.77, and DOR was 38 (95% CI, 7-198). Based on bivariate meta-regression analysis, a significantly higher specificity for diaphragm thickening fraction and higher sensitivity for diaphragmatic excursion was detected in studies with applicability concerns. Lung and diaphragm ultrasound can help predict weaning outcome, but its accuracy may vary depending on the patient subpopulation. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Raeder, K.; Anderson, J. L.; Lauritzen, P. H.; Hoar, T. J.; Collins, N.
2010-12-01
DART (www.image.ucar.edu/DAReS/DART) is a general purpose, freely available, ensemble Kalman filter, data assimilation system, which is being used to generate state-of-the-art, partially coupled, ocean-atmosphere re-analyses in support of the decadal predictions planned for the next IPCC report. The resulting gridded product is directly comparable to the state variables output by POP and CAM (oceanic and atmospheric components of NCAR's Community Earth System Model climate model) because those are the assimilating models. Other models could also benefit from comparison against these reanalyses, since the ocean analyses are at the leading edge of ocean state estimation, and the atmospheric analyses are competitive with operational centers'. Such comparisons can reveal model biases and predictability characteristics, and do so in a quantitative way, since the ensemble nature of the analyses provides an objective estimate of the analysis error. The analyses will also be used as initial conditions for the decadal forecasts because they are the most realistic available. The generation of such analyses has revealed errors in model formulation for several versions of the finite volume core CAM, which has led to model improvements in each case. New models can be incorporated into DART in a matter of weeks, allowing them to be compared directly against available observations. The observations currently used in the assimilations include, for the ocean; temperature and salinity from the World Ocean Database (floats, drifters, moorings, autonomous pinipeds, and others), and for the atmosphere; temperature and winds from radiosondes, satellite drift winds, ACARS and aircraft. Observations of ocean currents and atmospheric moisture and pressure are also available. Global Positioning System profiles of atmospheric temperature and moisture are available for recent years. All that is required to add new observations to the suite is the forward operator, which generates an estimate of the observation from the model state. In summary, DART provides a flexible, convenient, rigorous environment for evaluating models in the context of real observations.
A general framework for the use of logistic regression models in meta-analysis.
Simmonds, Mark C; Higgins, Julian Pt
2016-12-01
Where individual participant data are available for every randomised trial in a meta-analysis of dichotomous event outcomes, "one-stage" random-effects logistic regression models have been proposed as a way to analyse these data. Such models can also be used even when individual participant data are not available and we have only summary contingency table data. One benefit of this one-stage regression model over conventional meta-analysis methods is that it maximises the correct binomial likelihood for the data and so does not require the common assumption that effect estimates are normally distributed. A second benefit of using this model is that it may be applied, with only minor modification, in a range of meta-analytic scenarios, including meta-regression, network meta-analyses and meta-analyses of diagnostic test accuracy. This single model can potentially replace the variety of often complex methods used in these areas. This paper considers, with a range of meta-analysis examples, how random-effects logistic regression models may be used in a number of different types of meta-analyses. This one-stage approach is compared with widely used meta-analysis methods including Bayesian network meta-analysis and the bivariate and hierarchical summary receiver operating characteristic (ROC) models for meta-analyses of diagnostic test accuracy. © The Author(s) 2014.
Power System Oscillatory Behaviors: Sources, Characteristics, & Analyses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Follum, James D.; Tuffner, Francis K.; Dosiek, Luke A.
This document is intended to provide a broad overview of the sources, characteristics, and analyses of natural and forced oscillatory behaviors in power systems. These aspects are necessarily linked. Oscillations appear in measurements with distinguishing characteristics derived from the oscillation’s source. These characteristics determine which analysis methods can be appropriately applied, and the results from these analyses can only be interpreted correctly with an understanding of the oscillation’s origin. To describe oscillations both at their source within a physical power system and within measurements, a perspective from the boundary between power system and signal processing theory has been adopted.
The Child Adolescent Bullying Scale (CABS): Psychometric evaluation of a new measure.
Strout, Tania D; Vessey, Judith A; DiFazio, Rachel L; Ludlow, Larry H
2018-06-01
While youth bullying is a significant public health problem, healthcare providers have been limited in their ability to identify bullied youths due to the lack of a reliable, and valid instrument appropriate for use in clinical settings. We conducted a multisite study to evaluate the psychometric properties of a new 22-item instrument for assessing youths' experiences of being bullied, the Child Adolescent Bullying Scale (CABS). The 20 items summed to produce the measure's score were evaluated here. Diagnostic performance was assessed through evaluation of sensitivity, specificity, predictive values, and area under receiver operating characteristic (AUROC) curve. A sample of 352 youths from diverse racial, ethnic, and geographic backgrounds (188 female, 159 male, 5 transgender, sample mean age 13.5 years) were recruited from two clinical sites. Participants completed the CABS and existing youth bullying measures. Analyses grounded in classical test theory, including assessments of reliability and validity, item analyses, and principal components analysis, were conducted. The diagnostic performance and test characteristics of the CABS were also evaluated. The CABS is comprised of one component, accounting for 67% of observed variance. Analyses established evidence of internal consistency reliability (Cronbach's α = 0.97), construct and convergent validity. Sensitivity was 84%, specificity was 65%, and the AUROC curve was 0.74 (95% CI: 0.69-0.80). Findings suggest that the CABS holds promise as a reliable, valid tool for healthcare provider use in screening for bullying exposure in the clinical setting. © 2018 Wiley Periodicals, Inc.
Fixation of operating point and measurement of turn on characteristics of IGBT F4-75R06W1E3
NASA Astrophysics Data System (ADS)
Haseena, A.; Subhash Joshi T., G.; George, Saly
2018-05-01
For the proficient operation of the Power electronic circuit, signal level performance of power electronic devices are very important. For getting good signal level characteristics, fixing operating point is very critical. Device deviates from the typical characteristics given in the datasheet due to the presence of stray components in the circuit lay out. Fixation of operating point of typical silicon IGBT and its turn on characteristics is discussed in this paper.
Statistical analyses and characteristics of volcanic tremor on Stromboli Volcano (Italy)
NASA Astrophysics Data System (ADS)
Falsaperla, S.; Langer, H.; Spampinato, S.
A study of volcanic tremor on Stromboli is carried out on the basis of data recorded daily between 1993 and 1995 by a permanent seismic station (STR) located 1.8km away from the active craters. We also consider the signal of a second station (TF1), which operated for a shorter time span. Changes in the spectral tremor characteristics can be related to modifications in volcanic activity, particularly to lava effusions and explosive sequences. Statistical analyses were carried out on a set of spectra calculated daily from seismic signals where explosion quakes were present or excluded. Principal component analysis and cluster analysis were applied to identify different classes of spectra. Three clusters of spectra are associated with two different states of volcanic activity. One cluster corresponds to a state of low to moderate activity, whereas the two other clusters are present during phases with a high magma column as inferred from the occurrence of lava fountains or effusions. We therefore conclude that variations in volcanic activity at Stromboli are usually linked to changes in the spectral characteristics of volcanic tremor. Site effects are evident when comparing the spectra calculated from signals synchronously recorded at STR and TF1. However, some major spectral peaks at both stations may reflect source properties. Statistical considerations and polarization analysis are in favor of a prevailing presence of P-waves in the tremor signal along with a position of the source northwest of the craters and at shallow depth.
2016-09-01
Characteristics of Silver Carp (Hypophthalmichthys molitrix) Using Video Analyses and Principles of Projectile Physics by Glenn R. Parsons, Ehlana Stell...2002) estimated maximum swim speeds of videotaped, captive, and free-ranging dolphins, Delphinidae, by timed sequential analyses of video frames... videos to estimate the swim speeds and leap characteristics of carp as they exit the waters’ surface. We used both direct estimates of swim speeds as
Predicting obstetric anal sphincter injuries in a modern obstetric population.
Meister, Melanie R L; Cahill, Alison G; Conner, Shayna N; Woolfolk, Candice L; Lowder, Jerry L
2016-09-01
Perineal lacerations are common at the time of vaginal delivery and may predispose patients to long-term pelvic floor disorders, such as urinary incontinence and pelvic organ prolapse. Obstetric anal sphincter injuries, which are the most severe form of perineal lacerations, result in disruption of the anal sphincter and, in some cases, the rectal mucosa during vaginal delivery. Long-term morbidity, including pain, pelvic floor disorders, fecal incontinence, and predisposition to recurrent injury at subsequent delivery may result. Despite several studies that have reported risk factors for obstetric anal sphincter injuries, no accurate risk prediction models have been developed. The purpose of this study was to identify risk factors and develop prediction models for perineal lacerations and obstetric anal sphincter injuries. This was a nested case control study within a retrospective cohort of consecutive term vaginal deliveries at 1 tertiary care facility from 2004-2008. Cases were patients with any perineal laceration that had been sustained during vaginal delivery; control subjects had no lacerations of any severity. Secondary analyses investigated obstetric anal sphincter injury (3rd- to 4(th)-degree laceration) vs no obstetric anal sphincter injury (0 to 2(nd)-degree laceration). Baseline characteristics were compared between groups with the use of the chi-square and Student t test. Adjusted odds ratios and 95% confidence intervals were calculated with the use of multivariable logistic regression. Prediction models were created and model performance was estimated with receiver-operator characteristic curve analysis. Receiver-operator characteristic curves were validated internally with the use of the bootstrap method to correct for bias within the model. Of the 5569 term vaginal deliveries that were recorded during the study period, complete laceration data were available in 5524 deliveries. There were 3382 perineal lacerations and 249 (4.5%) obstetric anal sphincter injuries. After adjusted analysis, significant predictors for laceration included nulliparity, non-black race, longer second stage, nonsmoking status, higher infant birthweight, and operative delivery. Private health insurance, labor induction, pushing duration, and regional anesthesia were not statistically significant in adjusted analyses. Significant risk factors for obstetric anal sphincter injury were similar to predictors for any laceration; nulliparity and operative vaginal delivery had the highest predictive value. Area under the curve for the predictive ability of the models was 0.70 for overall perineal laceration, and 0.83 for obstetric anal sphincter injury. When limited to primiparous patients, 1996 term vaginal deliveries were recorded. One hundred ninety-two women sustained an obstetric anal sphincter injury; 1796 women did not. After adjusted analysis, significant predictors for laceration included non-black race, age, obesity, and nonsmoking status. In secondary analyses, significant predictors for obstetric anal sphincter injury included non-black race, nonsmoking status, longer duration of pushing, operative vaginal delivery, and infant birthweight. Area under the curve for the predictive ability of the models was 0.60 for any laceration and 0.77 for obstetric anal sphincter injury. Significant risk factors for sustaining any laceration and obstetric anal sphincter injury during vaginal deliveries were identified. These results will help identify clinically at-risk patients and assist providers in counseling patients about modifications to decrease these risks. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Bailey, R. E.; Smith, R. E.
1982-01-01
An investigation of pilot-induced oscillation suppression (PIOS) filters was performed using the USAF/Flight Dynamics Laboratory variable stability NT-33 aircraft, modified and operated by Calspan. This program examined the effects of PIOS filtering on the longitudinal flying qualities of fighter aircraft during the visual approach and landing task. Forty evaluations were flown to test the effects of different PIOS filters. Although detailed analyses were not undertaken, the results indicate that PIOS filtering can improve the flying qualities of an otherwise unacceptable aircraft configuration (Level 3 flying qualities). However, the ability of the filters to suppress pilot-induced oscillations appears to be dependent upon the aircraft configuration characteristics. Further, the data show that the filters can adversely affect landing flying qualities if improperly designed. The data provide an excellent foundation from which detail analyses can be performed.
Rotolo, Federico; Paoletti, Xavier; Burzykowski, Tomasz; Buyse, Marc; Michiels, Stefan
2017-01-01
Surrogate endpoints are often used in clinical trials instead of well-established hard endpoints for practical convenience. The meta-analytic approach relies on two measures of surrogacy: one at the individual level and one at the trial level. In the survival data setting, a two-step model based on copulas is commonly used. We present a new approach which employs a bivariate survival model with an individual random effect shared between the two endpoints and correlated treatment-by-trial interactions. We fit this model using auxiliary mixed Poisson models. We study via simulations the operating characteristics of this mixed Poisson approach as compared to the two-step copula approach. We illustrate the application of the methods on two individual patient data meta-analyses in gastric cancer, in the advanced setting (4069 patients from 20 randomized trials) and in the adjuvant setting (3288 patients from 14 randomized trials).
A transient model of the RL10A-3-3A rocket engine
NASA Technical Reports Server (NTRS)
Binder, Michael P.
1995-01-01
RL10A-3-3A rocket engines have served as the main propulsion system for Centaur upper stage vehicles since the early 1980's. This hydrogen/oxygen expander cycle engine continues to play a major role in the American launch industry. The Space Propulsion Technology Division at the NASA Lewis Research Center has created a computer model of the RL10 engine, based on detailed component analyses and available test data. This RL10 engine model can predict the performance of the engine over a wide range of operating conditions. The model may also be used to predict the effects of any proposed design changes and anticipated failure scenarios. In this paper, the results of the component analyses are discussed. Simulation results from the new system model are compared with engine test and flight data, including the start and shut-down transient characteristics.
Khanfar, Mohammad A; Banat, Fahmy; Alabed, Shada; Alqtaishat, Saja
2017-02-01
High expression of Nek2 has been detected in several types of cancer and it represents a novel target for human cancer. In the current study, structure-based pharmacophore modeling combined with multiple linear regression (MLR)-based QSAR analyses was applied to disclose the structural requirements for NEK2 inhibition. Generated pharmacophoric models were initially validated with receiver operating characteristic (ROC) curve, and optimum models were subsequently implemented in QSAR modeling with other physiochemical descriptors. QSAR-selected models were implied as 3D search filters to mine the National Cancer Institute (NCI) database for novel NEK2 inhibitors, whereas the associated QSAR model prioritized the bioactivities of captured hits for in vitro evaluation. Experimental validation identified several potent NEK2 inhibitors of novel structural scaffolds. The most potent captured hit exhibited an [Formula: see text] value of 237 nM.
The impact of applied behavior analysis on diverse areas of research.
Kazdin, A E
1975-01-01
The impact of applied behavior analysis on various disciplines and areas of research was assessed through two major analyses. First, the relationship of applied behavior analysis to the general area of "behavior modification" was evaluated by examining the citation characteristics of journal articles in JABA and three other behavior-modification journals. Second, the penetration of applied behavior analysis into diverse areas and disciplines, including behavior modification, psychiatry, clinical psychology, education, special education, retardation, speech and hearing, counselling, and law enforcement and correction was assessed. Twenty-five journals representing diverse research areas were evaluated from 1968 to 1974 to assess the extent to which operant techniques were applied for therapeutic, rehabilitative, and educative purposes and the degree to which methodological desiderata of applied behavior analysis were met. The analyses revealed diverse publication outlets for applied behavior analysis in various disciplines. PMID:1184488
Smooth time-dependent receiver operating characteristic curve estimators.
Martínez-Camblor, Pablo; Pardo-Fernández, Juan Carlos
2018-03-01
The receiver operating characteristic curve is a popular graphical method often used to study the diagnostic capacity of continuous (bio)markers. When the considered outcome is a time-dependent variable, two main extensions have been proposed: the cumulative/dynamic receiver operating characteristic curve and the incident/dynamic receiver operating characteristic curve. In both cases, the main problem for developing appropriate estimators is the estimation of the joint distribution of the variables time-to-event and marker. As usual, different approximations lead to different estimators. In this article, the authors explore the use of a bivariate kernel density estimator which accounts for censored observations in the sample and produces smooth estimators of the time-dependent receiver operating characteristic curves. The performance of the resulting cumulative/dynamic and incident/dynamic receiver operating characteristic curves is studied by means of Monte Carlo simulations. Additionally, the influence of the choice of the required smoothing parameters is explored. Finally, two real-applications are considered. An R package is also provided as a complement to this article.
Concurrent airline fleet allocation and aircraft design with profit modeling for multiple airlines
NASA Astrophysics Data System (ADS)
Govindaraju, Parithi
A "System of Systems" (SoS) approach is particularly beneficial in analyzing complex large scale systems comprised of numerous independent systems -- each capable of independent operations in their own right -- that when brought in conjunction offer capabilities and performance beyond the constituents of the individual systems. The variable resource allocation problem is a type of SoS problem, which includes the allocation of "yet-to-be-designed" systems in addition to existing resources and systems. The methodology presented here expands upon earlier work that demonstrated a decomposition approach that sought to simultaneously design a new aircraft and allocate this new aircraft along with existing aircraft in an effort to meet passenger demand at minimum fleet level operating cost for a single airline. The result of this describes important characteristics of the new aircraft. The ticket price model developed and implemented here enables analysis of the system using profit maximization studies instead of cost minimization. A multiobjective problem formulation has been implemented to determine characteristics of a new aircraft that maximizes the profit of multiple airlines to recognize the fact that aircraft manufacturers sell their aircraft to multiple customers and seldom design aircraft customized to a single airline's operations. The route network characteristics of two simple airlines serve as the example problem for the initial studies. The resulting problem formulation is a mixed-integer nonlinear programming problem, which is typically difficult to solve. A sequential decomposition strategy is applied as a solution methodology by segregating the allocation (integer programming) and aircraft design (non-linear programming) subspaces. After solving a simple problem considering two airlines, the decomposition approach is then applied to two larger airline route networks representing actual airline operations in the year 2005. The decomposition strategy serves as a promising technique for future detailed analyses. Results from the profit maximization studies favor a smaller aircraft in terms of passenger capacity due to its higher yield generation capability on shorter routes while results from the cost minimization studies favor a larger aircraft due to its lower direct operating cost per seat mile.
Fardell, Joanna E; Jones, Georden; Smith, Allan Ben; Lebel, Sophie; Thewes, Belinda; Costa, Daniel; Tiller, Kerry; Simard, Sébastien; Feldstain, Andrea; Beattie, Sara; McCallum, Megan; Butow, Phyllis
2018-02-01
Fear of cancer recurrence (FCR) is a common concern among cancer survivors. Identifying survivors with clinically significant FCR requires validated screening measures and clinical cut-offs. We evaluated the Fear of Cancer Recurrence Inventory-Short Form (FCRI-SF) clinical cut-off in 2 samples. Level of FCR in study 1 participants (from an Australian randomized controlled trial: ConquerFear) was compared with FCRI-SF scores. Based on a biopsychosocial interview, clinicians rated participants as having nonclinical, subclinical, or clinical FCR. Study 2 participants (from a Canadian FCRI-English validation study) were classified as having clinical or nonclinical FCR by using the semistructured clinical interview for FCR (SIFCR). Receiver operating characteristic analyses evaluated the screening ability of the FCRI-SF against clinician ratings (study 1) and the SIFCR (study 2). In study 1, 167 cancer survivors (mean age: 53 years, SD = 10.1) participated. Clinicians rated 43% as having clinical FCR. In study 2, 40 cancer survivors (mean age: 68 years, SD = 7.0) participated; 25% met criteria for clinical FCR according to the SIFCR. For both studies 1 and 2, receiver operating characteristic analyses suggested a cut-off ≥22 on the FCRI-SF identified cancer survivors with clinical levels of FCR with adequate sensitivity and specificity. Establishing clinical cut-offs on FCR screening measures is crucial to tailoring individual care and conducting rigorous research. Our results suggest using a higher cut-off on the FCRI-SF than previously reported to identify clinically significant FCR. Continued evaluation and validation of the FCRI-SF cut-off is required across diverse cancer populations. Copyright © 2017 John Wiley & Sons, Ltd.
Burke, Danielle L; Ensor, Joie; Snell, Kym I E; van der Windt, Danielle; Riley, Richard D
2018-06-01
Percentage study weights in meta-analysis reveal the contribution of each study toward the overall summary results and are especially important when some studies are considered outliers or at high risk of bias. In meta-analyses of test accuracy reviews, such as a bivariate meta-analysis of sensitivity and specificity, the percentage study weights are not currently derived. Rather, the focus is on representing the precision of study estimates on receiver operating characteristic plots by scaling the points relative to the study sample size or to their standard error. In this article, we recommend that researchers should also provide the percentage study weights directly, and we propose a method to derive them based on a decomposition of Fisher information matrix. This method also generalises to a bivariate meta-regression so that percentage study weights can also be derived for estimates of study-level modifiers of test accuracy. Application is made to two meta-analyses examining test accuracy: one of ear temperature for diagnosis of fever in children and the other of positron emission tomography for diagnosis of Alzheimer's disease. These highlight that the percentage study weights provide important information that is otherwise hidden if the presentation only focuses on precision based on sample size or standard errors. Software code is provided for Stata, and we suggest that our proposed percentage weights should be routinely added on forest and receiver operating characteristic plots for sensitivity and specificity, to provide transparency of the contribution of each study toward the results. This has implications for the PRISMA-diagnostic test accuracy guidelines that are currently being produced. Copyright © 2017 John Wiley & Sons, Ltd.
Peters, Lilian L; Thornton, Charlene; de Jonge, Ank; Khashan, Ali; Tracy, Mark; Downe, Soo; Feijen-de Jong, Esther I; Dahlen, Hannah G
2018-03-25
Spontaneous vaginal birth rates are decreasing worldwide, while cesarean delivery, instrumental births, and medical birth interventions are increasing. Emerging evidence suggests that birth interventions may have an effect on children's health. Therefore, the aim of our study was to examine the association between operative and medical birth interventions on the child's health during the first 28 days and up to 5 years of age. In New South Wales (Australia), population-linked data sets were analyzed, including data on maternal characteristics, child characteristics, mode of birth, interventions during labor and birth, and adverse health outcomes of the children (ie, jaundice, feeding problems, hypothermia, asthma, respiratory infections, gastrointestinal disorders, other infections, metabolic disorder, and eczema) registered with the International Statistical Classification of Diseases and Related Health Problems, Tenth Revision, Australian Modification codes. Logistic regression analyses were performed for each adverse health outcome. Our analyses included 491 590 women and their children; of those 38% experienced a spontaneous vaginal birth. Infants who experienced an instrumental birth after induction or augmentation had the highest risk of jaundice, adjusted odds ratio (aOR) 2.75 (95% confidence interval [CI] 2.61-2.91) compared with spontaneous vaginal birth. Children born by cesarean delivery were particularly at statistically significantly increased risk for infections, eczema, and metabolic disorder, compared with spontaneous vaginal birth. Children born by emergency cesarean delivery showed the highest association for metabolic disorder, aOR 2.63 (95% CI 2.26-3.07). Children born by spontaneous vaginal birth had fewer short- and longer-term health problems, compared with those born after birth interventions. © 2018 the Authors. Birth published by Wiley Periodicals, Inc.
Valdes, Pablo A; Bekelis, Kimon; Harris, Brent T; Wilson, Brian C; Leblond, Frederic; Kim, Anthony; Simmons, Nathan E; Erkmen, Kadir; Paulsen, Keith D; Roberts, David W
2014-03-01
The use of 5-aminolevulinic acid (ALA)-induced protoporphyrin IX (PpIX) fluorescence has shown promise as a surgical adjunct for maximizing the extent of surgical resection in gliomas. To date, the clinical utility of 5-ALA in meningiomas is not fully understood, with most descriptive studies using qualitative approaches to 5-ALA-PpIX. To assess the diagnostic performance of 5-ALA-PpIX fluorescence during surgical resection of meningioma. ALA was administered to 15 patients with meningioma undergoing PpIX fluorescence-guided surgery at our institution. At various points during the procedure, the surgeon performed qualitative, visual assessments of fluorescence by using the surgical microscope, followed by a quantitative fluorescence measurement by using an intraoperative probe. Specimens were collected at each point for subsequent neuropathological analysis. Clustered data analysis of variance was used to ascertain a difference between groups, and receiver operating characteristic analyses were performed to assess diagnostic capabilities. Red-pink fluorescence was observed in 80% (12/15) of patients, with visible fluorescence generally demonstrating a strong, homogenous character. Quantitative fluorescence measured diagnostically significant PpIX concentrations (cPpIx) in both visibly and nonvisibly fluorescent tissues, with significantly higher cPpIx in both visibly fluorescent (P < .001) and tumor tissue (P = .002). Receiver operating characteristic analyses also showed diagnostic accuracies up to 90% for differentiating tumor from normal dura. ALA-induced PpIX fluorescence guidance is a potential and promising adjunct in accurately detecting neoplastic tissue during meningioma resective surgery. These results suggest a broader reach for PpIX as a biomarker for meningiomas than was previously noted in the literature.
Study on efficiency of different topologies of magnetic coupled resonant wireless charging system
NASA Astrophysics Data System (ADS)
Cui, S.; Liu, Z. Z.; Hou, Y. J.; Zeng, H.; Yue, Z. K.; Liang, L. H.
2017-11-01
This paper analyses the relationship between the output power, the transmission efficiency and the frequency, load and coupling coefficient of the four kinds of magnetic coupled resonant wireless charging system topologies. Based on mutual inductance principle, four kinds of circuit models are established, and the expressions of output power and transmission efficiency of different structures are calculated. The difference between the two power characteristics and efficiency characteristics is compared by simulating the SS (series-series) and SP (series-parallel) type wireless charging systems. With the same parameters of circuit components, the SS structure is usually suitable for small load resistance. The SP structure can be applied to large load resistors, when the transmission efficiency of the system is required to keep high. If the operating frequency deviates from the system resonance frequency, the SS type system has higher transmission efficiency than the SP type system.
Chen, J J; Lien, W P; Chang, F Z; Lee, Y S; Hung, C R; Chu, S S; Wu, T L
1980-02-01
Clinical features of 19 cases with congenital aneurysm of the right sinus of Valsalva rupturing into the right ventricular outflow region (Type 1) were analysed in relation to their pathoanatomic lesions and hemodynamic alterations. Sixteen cases were operated with one surgical death. All were catheterized together with ascending aortographic study. Rupture of the aneurysm in many cases was silent or symptomless and progressive heart failure was not quite common. Symptomatology of the patients did not seem to be related entirely to status of the pathoanatomical lesions or hemodynamic alterations. Time of the rupture, and inherent right ventricular characteristics, tolerating volume overload rather well, might be, in part, responsible for its better prognosis in some cases. However, all patients with ruptured aneurysm of the sinus of Valsalva should be treated surgically. Bacterial endocarditis is a serious complication leading to death.
A Four-Feet Walking-Type Rotary Piezoelectric Actuator with Minute Step Motion.
Liu, Yingxiang; Wang, Yun; Liu, Junkao; Xu, Dongmei; Li, Kai; Shan, Xiaobiao; Deng, Jie
2018-05-08
A four-feet walking-type rotary piezoelectric actuator with minute step motion was proposed. The proposed actuator used the rectangular motions of four driving feet to push the rotor step-by-step; this operating principle was different with the previous non-resonant actuators using direct-driving, inertial-driving, and inchworm-type mechanisms. The mechanism of the proposed actuator was discussed in detail. Transient analyses were accomplished by ANSYS software to simulate the motion trajectory of the driving foot and to find the response characteristics. A prototype was manufactured to verify the mechanism and to test the mechanical characteristics. A minimum resolution of 0.095 μrad and a maximum torque of 49 N·mm were achieved by the prototype, and the output speed was varied by changing the driving voltage and working frequency. This work provides a new mechanism for the design of a rotary piezoelectric actuator with minute step motion.
Charged particle concepts for fog dispersion
NASA Technical Reports Server (NTRS)
Frost, W.; Collins, F. G.; Koepf, D.
1981-01-01
Charged particle techniques hold promise for dispersing warm fog in the terminal area of commercial airports. This report focuses on features of the charged particle technique which require further study. The basic physical principles of the technique and the major verification experiments carried out in the past are described. The fundamentals of the nozzle operation are given. The nozzle characteristics and the theory of particle charging in the nozzle are discussed, including information from extensive literature on electrostatic precipitation relative to environmental pollution control and a description of some preliminary reported analyses on the jet characteristics and interaction with neighboring jets. The equation governing the transfer of water substances and of electrical charge is given together with a brief description of several semi-empirical, mathematical expressions necessary for the governing equations. The necessary ingredients of a field experiment to verify the system once a prototype is built are described.
NASA Astrophysics Data System (ADS)
Yongzhi, WANG; hui, WANG; Lixia, LIAO; Dongsen, LI
2017-02-01
In order to analyse the geological characteristics of salt rock and stability of salt caverns, rough three-dimensional (3D) models of salt rock stratum and the 3D models of salt caverns on study areas are built by 3D GIS spatial modeling technique. During implementing, multi-source data, such as basic geographic data, DEM, geological plane map, geological section map, engineering geological data, and sonar data are used. In this study, the 3D spatial analyzing and calculation methods, such as 3D GIS intersection detection method in three-dimensional space, Boolean operations between three-dimensional space entities, three-dimensional space grid discretization, are used to build 3D models on wall rock of salt caverns. Our methods can provide effective calculation models for numerical simulation and analysis of the creep characteristics of wall rock in salt caverns.
A Four-Feet Walking-Type Rotary Piezoelectric Actuator with Minute Step Motion
Wang, Yun; Liu, Junkao; Xu, Dongmei; Li, Kai; Shan, Xiaobiao; Deng, Jie
2018-01-01
A four-feet walking-type rotary piezoelectric actuator with minute step motion was proposed. The proposed actuator used the rectangular motions of four driving feet to push the rotor step-by-step; this operating principle was different with the previous non-resonant actuators using direct-driving, inertial-driving, and inchworm-type mechanisms. The mechanism of the proposed actuator was discussed in detail. Transient analyses were accomplished by ANSYS software to simulate the motion trajectory of the driving foot and to find the response characteristics. A prototype was manufactured to verify the mechanism and to test the mechanical characteristics. A minimum resolution of 0.095 μrad and a maximum torque of 49 N·mm were achieved by the prototype, and the output speed was varied by changing the driving voltage and working frequency. This work provides a new mechanism for the design of a rotary piezoelectric actuator with minute step motion. PMID:29738495
Feguš, Urban; Žigon, Uroš; Petermann, Marcus; Knez, Željko
2015-01-01
Aim of this experimental work was to investigate the possibility of producing fruit powders without employing drying aid and to investigate the effect of drying temperatures on the final powder characteristics. Raw fruit materials (banana puree, strawberry puree and blueberry concentrate) were processed using three different drying techniques each operating at a different temperature conditions: vacuum-drying (-27-17 °C), Spray-drying (130-160 °C) and PGSS-drying (112-152 °C). Moisture content, total colour difference, antioxidant activity and sensory characteristics of the processed fruit powders were analysed. The results obtained from the experimental work indicate that investigated fruit powders without or with minimal addition of maltodextrin can be produced. Additionally, it was observed that an increase in process temperature results in a higher loss of colour, antioxidant activity and intensity of the flavour profile.
Fusion characteristics of volcanic ash relevant to aviation hazards
NASA Astrophysics Data System (ADS)
Song, Wenjia; Hess, Kai-Uwe; Damby, David E.; Wadsworth, Fabian B.; Lavallée, Yan; Cimarelli, Corrado; Dingwell, Donald B.
2014-04-01
The fusion dynamics of volcanic ash strongly impacts deposition in hot parts of jet engines. In this study, we investigate the sintering behavior of volcanic ash using natural ash of intermediate composition, erupted in 2012 at Santiaguito Volcano, Guatemala. A material science procedure was followed in which we monitored the geometrical evolution of cylindrical-shaped volcanic ash compact upon heating from 50 to 1400°C in a heating microscope. Combined morphological, mineralogical, and rheological analyses helped define the evolution of volcanic ash during fusion and sintering and constrain their sticking potential as well as their ability to flow at characteristic temperatures. For the ash investigated, 1240°C marks the onset of adhesion and flowability. The much higher fusibility of ash compared to that of typical test sands demonstrates for the need of a more extensive fusion characterization of volcanic ash in order to mitigate the risk posed on jet engine operation.
NASA Astrophysics Data System (ADS)
Li, Huanhuan; Chen, Diyi; Zhang, Hao; Wang, Feifei; Ba, Duoduo
2016-12-01
In order to study the nonlinear dynamic behaviors of a hydro-turbine governing system in the process of sudden load increase transient, we establish a novel nonlinear dynamic model of the hydro-turbine governing system which considers the elastic water-hammer model of the penstock and the second-order model of the generator. The six nonlinear dynamic transfer coefficients of the hydro-turbine are innovatively proposed by utilizing internal characteristics and analyzing the change laws of the characteristic parameters of the hydro-turbine governing system. Moreover, from the point of view of engineering, the nonlinear dynamic behaviors of the above system are exhaustively investigated based on bifurcation diagrams and time waveforms. More importantly, all of the above analyses supply theoretical basis for allowing a hydropower station to maintain a stable operation in the process of sudden load increase transient.
Using Cryptography to Improve Conjunction Analysis
NASA Astrophysics Data System (ADS)
Hemenway, B.; Welser, B.; Baiocchi, D.
2012-09-01
Coordination of operations between satellite operators is becoming increasingly important to prevent collisions. Unfortunately, this coordination is often handicapped by a lack of trust. Coordination and cooperation between satellite operators can take many forms, however, one specific area where cooperation between operators would yield significant benefits is in the computation of conjunction analyses. Passively collected orbital are of generally of too low fidelity to be of use in conjunction analyses. Each operator, however, maintains high fidelity data about their own satellites. These high fidelity data are significantly more valuable in calculating conjunction analyses than the lower-fidelity data. If operators were to share their high fidelity data overall space situational awareness could be improved. At present, many operators do not share data and as a consequence space situational awareness suffers. Restrictive data sharing policies are primarily motivated by privacy concerns on the part of the satellite operators, as each operator is reluctant or unwilling to share data that might compromise its political or commercial interests. In order to perform the necessary conjunction analyses while still maintaining the privacy of their own data, a few operators have entered data sharing agreements. These operators provide their private data to a trusted outside party, who then performs the conjunction analyses and reports the results to the operators. These types of agreements are not an ideal solution as they require a degree of trust between the parties, and the cost of employing the trusted party can be large. In this work, we present and analyze cryptographic tools that would allow satellite operators to securely calculate conjunction analyses without the help of a trusted outside party, while provably maintaining the privacy of their own orbital information. For example, recent advances in cryptographic protocols, specifically in the area of secure Multiparty Computation (MPC) have the potential to allow satellite operators to perform the necessary conjunction analyses without the need to reveal their orbital information to anyone. This talk will describe how MPC works, and how we propose to use it to facilitate secure information sharing between satellite operators.
Psychopathy and criminal violence: the moderating effect of ethnicity.
Walsh, Zach
2013-10-01
This study aimed to determine the cross-ethnic stability of the predictive relationship of psychopathy for violence. Participants were 424 adult male jail inmates. Psychopathy was assessed using the Psychopathy Checklist-Revised and criminal violence was assessed using a comprehensive database of arrests for violent crimes. Ethnic categories included the groups that make up the vast majority of U.S. inmates: European American (EA, n = 166), African American (AA, n = 174), and Latino American (LA, n = 84). Ethnically aggregated Cox regression survival analyses identified predictive effects for psychopathy. Disaggregated analyses identified ethnic differences: Psychopathy was more strongly predictive of violence among EA (R² = .13, 95% CI [.04, .22], p < .01) relative to AA inmates (R² = .05, 95% CI [.00, .11], p < .01) and was not related to violence among LA participants (R² = .02, 95% CI [.00, .08], p = .22). Receiver operating characteristic curve analyses yielded an equivalent pattern of results. These findings add to a growing literature suggesting cross-ethnic variability in the predictive power of psychopathy for violence. PsycINFO Database Record (c) 2013 APA, all rights reserved
Research on gas within transformer oil based on photo-spectroscopy technology
NASA Astrophysics Data System (ADS)
Song, Gui-cai; Na, Yan-xiang; Zhang, Qi; Shi, Wen-zong
2011-08-01
Insulating oil is widely used in transformer and other large high-voltage electrical equipment.Its main functions are insulation, cooling and arc extinction. When the transformer runs, it may emit heat or discharge, which generate gas, micro water and trace metals in transformer oil. This will not only reduce the insulation capacity of insulating oil,and will greatly reduce the ability of its extinction, causing the transformers or other oil-filled electrical equipment appearing Internal latent malfunction, which would affect the operation of equipment. In this Paper, we simulate the transformer discharge effect to discharge in transformer oil. Then we use spectral theory and photo-spectroscopy technology to measure and analyse the oil sample, combining with IR absorption peaks of main fault characteristic gases, and qualitatively analyse CO, CO2, CH4, C2H6, C2H4, C2H2, H2 in gas mixture. The results show that the Fourier transform infrared spectroscopy can be very effective for analysing gases in transformer oil, which can quickly detect possible problems in the equipment.
Validation of a digital audio recording method for the objective assessment of cough in the horse.
Duz, M; Whittaker, A G; Love, S; Parkin, T D H; Hughes, K J
2010-10-01
To validate the use of digital audio recording and analysis for quantification of coughing in horses. Part A: Nine simultaneous digital audio and video recordings were collected individually from seven stabled horses over a 1 h period using a digital audio recorder attached to the halter. Audio files were analysed using audio analysis software. Video and audio recordings were analysed for cough count and timing by two blinded operators on two occasions using a randomised study design for determination of intra-operator and inter-operator agreement. Part B: Seventy-eight hours of audio recordings obtained from nine horses were analysed once by two blinded operators to assess inter-operator repeatability on a larger sample. Part A: There was complete agreement between audio and video analyses and inter- and intra-operator analyses. Part B: There was >97% agreement between operators on number and timing of 727 coughs recorded over 78 h. The results of this study suggest that the cough monitor methodology used has excellent sensitivity and specificity for the objective assessment of cough in horses and intra- and inter-operator variability of recorded coughs is minimal. Crown Copyright 2010. Published by Elsevier India Pvt Ltd. All rights reserved.
Verification of Meteorological and Oceanographic Ensemble Forecasts in the U.S. Navy
NASA Astrophysics Data System (ADS)
Klotz, S.; Hansen, J.; Pauley, P.; Sestak, M.; Wittmann, P.; Skupniewicz, C.; Nelson, G.
2013-12-01
The Navy Ensemble Forecast Verification System (NEFVS) has been promoted recently to operational status at the U.S. Navy's Fleet Numerical Meteorology and Oceanography Center (FNMOC). NEFVS processes FNMOC and National Centers for Environmental Prediction (NCEP) meteorological and ocean wave ensemble forecasts, gridded forecast analyses, and innovation (observational) data output by FNMOC's data assimilation system. The NEFVS framework consists of statistical analysis routines, a variety of pre- and post-processing scripts to manage data and plot verification metrics, and a master script to control application workflow. NEFVS computes metrics that include forecast bias, mean-squared error, conditional error, conditional rank probability score, and Brier score. The system also generates reliability and Receiver Operating Characteristic diagrams. In this presentation we describe the operational framework of NEFVS and show examples of verification products computed from ensemble forecasts, meteorological observations, and forecast analyses. The construction and deployment of NEFVS addresses important operational and scientific requirements within Navy Meteorology and Oceanography. These include computational capabilities for assessing the reliability and accuracy of meteorological and ocean wave forecasts in an operational environment, for quantifying effects of changes and potential improvements to the Navy's forecast models, and for comparing the skill of forecasts from different forecast systems. NEFVS also supports the Navy's collaboration with the U.S. Air Force, NCEP, and Environment Canada in the North American Ensemble Forecast System (NAEFS) project and with the Air Force and the National Oceanic and Atmospheric Administration (NOAA) in the National Unified Operational Prediction Capability (NUOPC) program. This program is tasked with eliminating unnecessary duplication within the three agencies, accelerating the transition of new technology, such as multi-model ensemble forecasting, to U.S. Department of Defense use, and creating a superior U.S. global meteorological and oceanographic prediction capability. Forecast verification is an important component of NAEFS and NUOPC. Distribution Statement A: Approved for Public Release; distribution is unlimited
Verification of Meteorological and Oceanographic Ensemble Forecasts in the U.S. Navy
NASA Astrophysics Data System (ADS)
Klotz, S. P.; Hansen, J.; Pauley, P.; Sestak, M.; Wittmann, P.; Skupniewicz, C.; Nelson, G.
2012-12-01
The Navy Ensemble Forecast Verification System (NEFVS) has been promoted recently to operational status at the U.S. Navy's Fleet Numerical Meteorology and Oceanography Center (FNMOC). NEFVS processes FNMOC and National Centers for Environmental Prediction (NCEP) meteorological and ocean wave ensemble forecasts, gridded forecast analyses, and innovation (observational) data output by FNMOC's data assimilation system. The NEFVS framework consists of statistical analysis routines, a variety of pre- and post-processing scripts to manage data and plot verification metrics, and a master script to control application workflow. NEFVS computes metrics that include forecast bias, mean-squared error, conditional error, conditional rank probability score, and Brier score. The system also generates reliability and Receiver Operating Characteristic diagrams. In this presentation we describe the operational framework of NEFVS and show examples of verification products computed from ensemble forecasts, meteorological observations, and forecast analyses. The construction and deployment of NEFVS addresses important operational and scientific requirements within Navy Meteorology and Oceanography (METOC). These include computational capabilities for assessing the reliability and accuracy of meteorological and ocean wave forecasts in an operational environment, for quantifying effects of changes and potential improvements to the Navy's forecast models, and for comparing the skill of forecasts from different forecast systems. NEFVS also supports the Navy's collaboration with the U.S. Air Force, NCEP, and Environment Canada in the North American Ensemble Forecast System (NAEFS) project and with the Air Force and the National Oceanic and Atmospheric Administration (NOAA) in the National Unified Operational Prediction Capability (NUOPC) program. This program is tasked with eliminating unnecessary duplication within the three agencies, accelerating the transition of new technology, such as multi-model ensemble forecasting, to U.S. Department of Defense use, and creating a superior U.S. global meteorological and oceanographic prediction capability. Forecast verification is an important component of NAEFS and NUOPC.
Forensic DNA phenotyping: Developing a model privacy impact assessment.
Scudder, Nathan; McNevin, Dennis; Kelty, Sally F; Walsh, Simon J; Robertson, James
2018-05-01
Forensic scientists around the world are adopting new technology platforms capable of efficiently analysing a larger proportion of the human genome. Undertaking this analysis could provide significant operational benefits, particularly in giving investigators more information about the donor of genetic material, a particularly useful investigative lead. Such information could include predicting externally visible characteristics such as eye and hair colour, as well as biogeographical ancestry. This article looks at the adoption of this new technology from a privacy perspective, using this to inform and critique the application of a Privacy Impact Assessment to this emerging technology. Noting the benefits and limitations, the article develops a number of themes that would influence a model Privacy Impact Assessment as a contextual framework for forensic laboratories and law enforcement agencies considering implementing forensic DNA phenotyping for operational use. Copyright © 2018 Elsevier B.V. All rights reserved.
New membranes based on ionic liquids for PEM fuel cells at elevated temperatures
NASA Astrophysics Data System (ADS)
Ye, H.; Huang, J.; Xu, J. J.; Kodiweera, N. K. A. C.; Jayakody, J. R. P.; Greenbaum, S. G.
Proton exchange membrane (PEM) fuel cells operating at elevated temperature, above 120 °C, will yield significant benefits but face big challenges for the development of suitable PEMs. The objectives of this research are to demonstrate the feasibility of the concept and realize [acid/ionic liquid/polymer] composite gel-type membranes as such PEMs. Novel membranes consisting of anhydrous proton solvent H 3PO 4, the protic ionic liquid PMIH 2PO 4, and polybenzimidazole (PBI) as a matrix have been prepared and characterized for PEM fuel cells intended for operation at elevated temperature (120-150 °C). Physical and electrochemical analyses have demonstrated promising characteristics of these H 3PO 4/PMIH 2PO 4/PBI membranes at elevated temperature. The proton transport mechanism in these new membranes has been investigated by Fourier transform infrared and nuclear magnetic resonance spectroscopic methods.
NASA Astrophysics Data System (ADS)
Terachi, Yusuke; Terao, Yutaka; Ohsaki, Hiroyuki; Sakurai, Yuki; Matsumura, Tomotake; Sugai, Hajime; Utsunomiya, Shin; Kataza, Hirokazu; Yamamoto, Ryo
2017-07-01
We have carried out numerical analysis of mechanical properties of a superconducting magnetic bearing (SMB). A contactless bearing operating at below 10 K with low rotational energy loss is an attractive feature to be used as a rotational mechanism of a polarization modulator for a cosmic microwave background experiment. In such application, a rotor diameter of about 400 mm forces us to employ a segmented magnet. As a result, there is inevitable spatial gap between the segments. In order to understand the path towards the design optimizations, 2D and 3D FEM analyses were carried out to examine fundamental characteristics of the SMBs for a polarization modulator. Two axial flux type SMBs were dealt with in the analysis: (a) the SMB with axially magnetized permanent magnets (PMs), and (b) the SMB with radially magnetized PMs and steel components for magnetic flux paths. Magnetic flux lines and density distributions, electromagnetic force characteristics, spring constants, etc. were compared among some variations of the SMBs. From the numerical analysis results, it is discussed what type, configuration and design of SMBs are more suitable for a polarization modulator.
Application of process tomography in gas-solid fluidised beds in different scales and structures
NASA Astrophysics Data System (ADS)
Wang, H. G.; Che, H. Q.; Ye, J. M.; Tu, Q. Y.; Wu, Z. P.; Yang, W. Q.; Ocone, R.
2018-04-01
Gas-solid fluidised beds are commonly used in particle-related processes, e.g. for coal combustion and gasification in the power industry, and the coating and granulation process in the pharmaceutical industry. Because the operation efficiency depends on the gas-solid flow characteristics, it is necessary to investigate the flow behaviour. This paper is about the application of process tomography, including electrical capacitance tomography (ECT) and microwave tomography (MWT), in multi-scale gas-solid fluidisation processes in the pharmaceutical and power industries. This is the first time that both ECT and MWT have been applied for this purpose in multi-scale and complex structure. To evaluate the sensor design and image reconstruction and to investigate the effects of sensor structure and dimension on the image quality, a normalised sensitivity coefficient is introduced. In the meantime, computational fluid dynamic (CFD) analysis based on a computational particle fluid dynamic (CPFD) model and a two-phase fluid model (TFM) is used. Part of the CPFD-TFM simulation results are compared and validated by experimental results from ECT and/or MWT. By both simulation and experiment, the complex flow hydrodynamic behaviour in different scales is analysed. Time-series capacitance data are analysed both in time and frequency domains to reveal the flow characteristics.
Loi, Felice; Marlowe, Karl
2017-01-01
Seclusion is a last resort intervention for management of aggressive behavior in psychiatric settings. There is no current objective and practical decision-making instrument for seclusion use on psychiatric wards. Our aim was to test the predictive and discriminatory characteristics of the East London Modified-Broset (ELMB), to delineate its decision-making profile for seclusion of adult psychiatric patients, and second to benchmark it against the psychometric properties of the Broset Violence Checklist (BVC). ELMB, an 8-item modified version of the 6-item BVC, was retrospectively employed to evaluate the seclusion decision-making process on two Psychiatric Intensive Care Units (patients n = 201; incidents n = 2,187). Data analyses were carried out using multivariate regression and Receiver Operating Characteristic (ROC) curves. Predictors of seclusion were: physical violence toward staff/patients OR = 24.2; non-compliance with PRN (pro re nata) medications OR = 9.8; and damage to hospital property OR = 2.9. ROC analyses indicated that ELMB was significantly more accurate that BVC, with higher sensitivity, specificity, and positive likelihood ratio. Results were similar across gender. The ELMB is a sensitive and specific instrument that can be used to guide the decision-making process when implementing seclusion.
Loi, Felice; Marlowe, Karl
2017-01-01
Seclusion is a last resort intervention for management of aggressive behavior in psychiatric settings. There is no current objective and practical decision-making instrument for seclusion use on psychiatric wards. Our aim was to test the predictive and discriminatory characteristics of the East London Modified-Broset (ELMB), to delineate its decision-making profile for seclusion of adult psychiatric patients, and second to benchmark it against the psychometric properties of the Broset Violence Checklist (BVC). ELMB, an 8-item modified version of the 6-item BVC, was retrospectively employed to evaluate the seclusion decision-making process on two Psychiatric Intensive Care Units (patients n = 201; incidents n = 2,187). Data analyses were carried out using multivariate regression and Receiver Operating Characteristic (ROC) curves. Predictors of seclusion were: physical violence toward staff/patients OR = 24.2; non-compliance with PRN (pro re nata) medications OR = 9.8; and damage to hospital property OR = 2.9. ROC analyses indicated that ELMB was significantly more accurate that BVC, with higher sensitivity, specificity, and positive likelihood ratio. Results were similar across gender. The ELMB is a sensitive and specific instrument that can be used to guide the decision-making process when implementing seclusion. PMID:29046647
Fernández del Río, R.; O'Hara, M.E.; Holt, A.; Pemberton, P.; Shah, T.; Whitehouse, T.; Mayhew, C.A.
2015-01-01
Background The burden of liver disease in the UK has risen dramatically and there is a need for improved diagnostics. Aims To determine which breath volatiles are associated with the cirrhotic liver and hence diagnostically useful. Methods A two-stage biomarker discovery procedure was used. Alveolar breath samples of 31 patients with cirrhosis and 30 healthy controls were mass spectrometrically analysed and compared (stage 1). 12 of these patients had their breath analysed after liver transplant (stage 2). Five patients were followed longitudinally as in-patients in the post-transplant period. Results Seven volatiles were elevated in the breath of patients versus controls. Of these, five showed statistically significant decrease post-transplant: limonene, methanol, 2-pentanone, 2-butanone and carbon disulfide. On an individual basis limonene has the best diagnostic capability (the area under a receiver operating characteristic curve (AUROC) is 0.91), but this is improved by combining methanol, 2-pentanone and limonene (AUROC curve 0.95). Following transplant, limonene shows wash-out characteristics. Conclusions Limonene, methanol and 2-pentanone are breath markers for a cirrhotic liver. This study raises the potential to investigate these volatiles as markers for early-stage liver disease. By monitoring the wash-out of limonene following transplant, graft liver function can be non-invasively assessed. PMID:26501124
A Circular Microstrip Antenna Sensor for Direction Sensitive Strain Evaluation †
Herbko, Michal
2018-01-01
In this paper, a circular microstrip antenna for stress evaluation is studied. This kind of microstrip sensor can be utilized in structural health monitoring systems. Reflection coefficient S11 is measured to determine deformation/strain value. The proposed sensor is adhesively connected to the studied sample. Applied strain causes a change in patch geometry and influences current distribution both in patch and ground plane. Changing the current flow in patch influences the value of resonant frequency. In this paper, two different resonant frequencies were analysed because in each case, different current distributions in patch were obtained. The sensor was designed for operating frequency of 2.5 GHz (at fundamental mode), which results in a diameter less than 55 mm. Obtained sensitivity was up to 1 MHz/100 MPa, resolution depends on utilized vector network analyser. Moreover, the directional characteristics for both resonant frequencies were defined, studied using numerical model and verified by measurements. Thus far, microstrip antennas have been used in deformation measurement only if the direction of external force was well known. Obtained directional characteristics of the sensor allow the determination of direction and value of stress by one sensor. This method of measurement can be an alternative to the rosette strain gauge. PMID:29361697
Impact of signal scattering and parametric uncertainties on receiver operating characteristics
NASA Astrophysics Data System (ADS)
Wilson, D. Keith; Breton, Daniel J.; Hart, Carl R.; Pettit, Chris L.
2017-05-01
The receiver operating characteristic (ROC curve), which is a plot of the probability of detection as a function of the probability of false alarm, plays a key role in the classical analysis of detector performance. However, meaningful characterization of the ROC curve is challenging when practically important complications such as variations in source emissions, environmental impacts on the signal propagation, uncertainties in the sensor response, and multiple sources of interference are considered. In this paper, a relatively simple but realistic model for scattered signals is employed to explore how parametric uncertainties impact the ROC curve. In particular, we show that parametric uncertainties in the mean signal and noise power substantially raise the tails of the distributions; since receiver operation with a very low probability of false alarm and a high probability of detection is normally desired, these tails lead to severely degraded performance. Because full a priori knowledge of such parametric uncertainties is rarely available in practice, analyses must typically be based on a finite sample of environmental states, which only partially characterize the range of parameter variations. We show how this effect can lead to misleading assessments of system performance. For the cases considered, approximately 64 or more statistically independent samples of the uncertain parameters are needed to accurately predict the probabilities of detection and false alarm. A connection is also described between selection of suitable distributions for the uncertain parameters, and Bayesian adaptive methods for inferring the parameters.
Ferro, Matteo; Lucarelli, Giuseppe; Bruzzese, Dario; Perdonà, Sisto; Mazzarella, Claudia; Perruolo, Giuseppe; Marino, Ada; Cosimato, Vincenzo; Giorgio, Emilia; Tagliamonte, Virginia; Bottero, Danilo; De Cobelli, Ottavio; Terracciano, Daniela
2015-02-01
Several efforts have been made to find biomarkers that could help clinicians to preoperatively determine prostate cancer (PCa) pathological characteristics and choose the best therapeutic approach, avoiding over-treatment. On this effort, prostate cancer antigen 3 (PCA3), prostate health index (phi) and sarcosine have been presented as promising tools. We evaluated the ability of these biomarkers to predict the pathologic PCa characteristics within a prospectively collected contemporary cohort of patients who underwent radical prostatectomy (RP) for clinically localized PCa at a single high-volume Institution. The prognostic performance of PCA3, phi and sarcosine were evaluated in 78 patients undergoing RP for biopsy-proven PCa. Receiver operating characteristic (ROC) curve analyses tested the accuracy (area under the curve (AUC)) in predicting PCa pathological characteristics. Decision curve analyses (DCA) were used to assess the clinical benefit of the three biomarkers. We found that PCA3, phi and sarcosine levels were significantly higher in patients with tumor volume (TV)≥0.5 ml, pathologic Gleason sum (GS)≥7 and pT3 disease (all p-values≤0.01). ROC curve analysis showed that phi is an accurate predictor of high-stage (AUC 0.85 [0.77-0.93]), high-grade (AUC 0.83 [0.73-0.93]) and high-volume disease (AUC 0.94 [0.88-0.99]). Sarcosine showed a comparable AUC (0.85 [0.76-0.94]) only for T3 stage prediction, whereas PCA3 score showed lower AUCs, ranging from 0.74 (for GS) to 0.86 (for TV). PCA3, phi and sarcosine are predictors of PCa characteristics at final pathology. Successful clinical translation of these findings would reduce the frequency of surveillance biopsies and may enhance acceptance of active surveillance (AS). Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Operation of staged membrane oxidation reactor systems
Repasky, John Michael
2012-10-16
A method of operating a multi-stage ion transport membrane oxidation system. The method comprises providing a multi-stage ion transport membrane oxidation system with at least a first membrane oxidation stage and a second membrane oxidation stage, operating the ion transport membrane oxidation system at operating conditions including a characteristic temperature of the first membrane oxidation stage and a characteristic temperature of the second membrane oxidation stage; and controlling the production capacity and/or the product quality by changing the characteristic temperature of the first membrane oxidation stage and/or changing the characteristic temperature of the second membrane oxidation stage.
Study on safety operation for large hydroelectric generator unit
NASA Astrophysics Data System (ADS)
Yan, Z. G.; Cui, T.; Zhou, L. J.; Zhi, F. L.; Wang, Z. W.
2012-11-01
Hydroelectric generator unit is a complex mechanical system which is composed of hydraulic turbine and electric generator. Rotary system is supported by the bearing bracket and the reinforced concrete structures, and vibration problem can't be avoided in the process of operating. Many large-scale hydroelectric units have been damaged because of the vibration problem in recent years. As the increase of the hydraulic turbine unit capacity and water head, the safe operation of hydraulic turbine has become a focus research in many countries. The operating characteristics of the hydraulic turbine have obvious differences at different working conditions. Based on the combination of field measurement and theoretical calculation, this paper shows a deep research on the safe operation of a large-scale Francis turbine unit. Firstly, the measurements of vibration, swing, pressure fluctuation and noise were carried out at 4 different heads. And also the relationships between vibrations and pressure fluctuations at different heads and working conditions were analysed deeply. Then the scientific prediction of safe operation for the unit at high head were done based on the CFD numerical calculation. Finally, this paper shows the division of the operating zone for the hydroelectric unit. According to the experimental results (vibrations, swings, pressure fluctuations and noise) as well as the theoretical results, the operating zone of the unit has been divided into three sections: prohibited operating zone, transition operating zone and safe operating zone. After this research was applied in the hydropower station, the security and economic efficiency of unit increased greatly, and enormous economic benefits and social benefits have been obtained.
Is Operative Treatment of Achilles Tendon Ruptures Superior to Nonoperative Treatment?
Erickson, Brandon J.; Mascarenhas, Randy; Saltzman, Bryan M.; Walton, David; Lee, Simon; Cole, Brian J.; Bach, Bernard R.
2015-01-01
Background: Multiple meta-analyses have been published in efforts to determine whether operative or nonoperative treatment of Achilles tendon ruptures affords superior outcomes. Purpose: To perform a systematic review of overlapping meta-analyses comparing operative and nonoperative treatment of Achilles tendon ruptures to determine which meta-analyses provide the highest level of evidence for treatment recommendations. Study Design: Systematic review; Level of evidence, 3. Methods: A systematic review of the literature was performed to identify meta-analyses that fit the study inclusion criteria. Data were extracted from these meta-analyses regarding patient outcomes and reruptures. Meta-analysis quality was assessed using the Oxman-Guyatt and QUOROM (Quality of Reporting of Meta-analyses) systems. The Jadad algorithm was applied to determine the meta-analyses with the highest level of evidence. Results: Nine meta-analyses met the eligibility criteria, with all but 1 study including level 1 evidence. A total of 5842 patients were included. Seven studies found a higher rate of rerupture in the nonoperative group but a higher rate of complications in the operative group. One study found no differences in rerupture or complication rates, and 1 study found surgery decreased rerupture rates only when compared with nonoperative treatment without a functional brace. Three studies also identified an earlier return to work in the operative group. Almost all (8 of 9) of the meta-analyses had Oxman-Guyatt scores >3, indicating no major flaws. Conclusion: Operative treatment of Achilles tendon ruptures decreases rerupture rates but increases the risk for minor complications when compared with nonoperative treatment. Additionally, surgical treatment may allow earlier return to work. PMID:26665055
Analysis of spacecraft battery charger systems
NASA Astrophysics Data System (ADS)
Kim, Seong J.; Cho, Bo H.
In spacecraft battery charger systems, switching regulators are widely used for bus voltage regulation, charge current regulation, and peak power tracking. Small-signal dynamic characteristics of the battery charging subsystem of direct energy transfer (DET) and peak power tracking (PPT) systems are analyzed to facilitate design of the control loop for optimum performance and stability. Control loop designs of the charger in various modes of operation are discussed. Analyses are verified through simulations. It is shown that when the charger operates in the bus voltage regulation mode, the control-to-voltage transfer function has a negative DC gain and two LHP zeros in both the DET and PPT systems. The control-to-inductor current transfer function also has a negative DC gain and a RHP zero. Thus, in the current-mode control, the current loop can no longer be used to stabilize the system. When the system operates in the charge current regulation mode, the charger operates with a fixed duty cycle which is determined by the regulated bus voltage and the battery voltage. Without an input filter, the converter becomes a first-order system. When the peak power tracker is inactive, the operating point of the solar array output moves to the voltage source region. Thus, the solar array behaves as a stiff voltage source to a constant power load.
NASA Astrophysics Data System (ADS)
Styrnoll, T.; Bienholz, S.; Lapke, M.; Awakowicz, P.
2014-04-01
This paper discusses plasma probe diagnostics, namely the multipole resonance probe (MRP) and Langmuir probe (LP), operated in depositing plasmas. The aim of this work is to show that the combination of both probes provides stable and robust measurements and clear determination of plasma parameters for metallic and ceramic coating processes. The probes use different approaches to determine plasma parameters, e.g. electron density ne and electron temperature Te. The LP is a well-established plasma diagnostic, and its applicability in technological plasmas is well documented. The LP is a dc probe that performs a voltage sweep and analyses the measured current, which makes it insensitive against conductive metallic coating. However, once the LP is dielectrically coated with a ceramic film, its functionality is constricted. In contrast, the MRP was recently presented as a monitoring tool, which is insensitive to coating with dielectric ceramics. It is a new plasma diagnostic based on the concept of active plasma resonance spectroscopy, which uses the universal characteristic of all plasmas to resonate on or near the electron plasma frequency. The MRP emits a frequency sweep and the absorption of the signal, the |S11| parameter, is analysed. Since the MRP concept is based on electromagnetic waves, which are able to transmit dielectrics, it is insensitive to dielectric coatings. But once the MRP is metallized with a thin conductive film, no undisturbed RF-signal can be emitted into the plasma, which leads to falsified plasma parameter. In order to compare both systems, during metallic or dielectric coating, the probes are operated in a magnetron CCP, which is equipped with a titanium target. We present measurements in metallic and dielectric coating processes with both probes and elaborate advantages and problems of each probe operated in each coating environment.
Orbit transfer rocket engine technology program
NASA Technical Reports Server (NTRS)
Gustafson, N. B.; Harmon, T. J.
1993-01-01
An advanced near term (1990's) space-based Orbit Transfer Vehicle Engine (OTVE) system was designed, and the technologies applicable to its construction, maintenance, and operations were developed under Tasks A through F of the Orbit Transfer Rocket Engine Technology Program. Task A was a reporting task. In Task B, promising OTV turbomachinery technologies were explored: two stage partial admission turbines, high velocity ratio diffusing crossovers, soft wear ring seals, advanced bearing concepts, and a rotordynamic analysis. In Task C, a ribbed combustor design was developed. Possible rib and channel geometries were chosen analytically. Rib candidates were hot air tested and laser velocimeter boundary layer analyses were conducted. A channel geometry was also chosen on the basis of laser velocimeter data. To verify the predicted heat enhancement effects, a ribbed calorimeter spool was hot fire tested. Under Task D, the optimum expander cycle engine thrust, performance and envelope were established for a set of OTV missions. Optimal nozzle contours and quick disconnects for modularity were developed. Failure Modes and Effects Analyses, maintenance and reliability studies and component study results were incorporated into the engine system. Parametric trades on engine thrust, mixture ratio, and area ratio were also generated. A control system and the health monitoring and maintenance operations necessary for a space-based engine were outlined in Task E. In addition, combustor wall thickness measuring devices and a fiberoptic shaft monitor were developed. These monitoring devices were incorporated into preflight engine readiness checkout procedures. In Task F, the Integrated Component Evaluator (I.C.E.) was used to demonstrate performance and operational characteristics of an advanced expander cycle engine system and its component technologies. Sub-system checkouts and a system blowdown were performed. Short transitions were then made into main combustor ignition and main stage operation.
Acoustic measurements for the combustion diagnosis of diesel engines fuelled with biodiesels
NASA Astrophysics Data System (ADS)
Zhen, Dong; Wang, Tie; Gu, Fengshou; Tesfa, Belachew; Ball, Andrew
2013-05-01
In this paper, an experimental investigation was carried out on the combustion process of a compression ignition (CI) engine running with biodiesel blends under steady state operating conditions. The effects of biodiesel on the combustion process and engine dynamics were analysed for non-intrusive combustion diagnosis based on a four-cylinder, four-stroke, direct injection and turbocharged diesel engine. The signals of vibration, acoustic and in-cylinder pressure were measured simultaneously to find their inter-connection for diagnostic feature extraction. It was found that the sound energy level increases with the increase of engine load and speed, and the sound characteristics are closely correlated with the variation of in-cylinder pressure and combustion process. The continuous wavelet transform (CWT) was employed to analyse the non-stationary nature of engine noise in a higher frequency range. Before the wavelet analysis, time synchronous average (TSA) was used to enhance the signal-to-noise ratio (SNR) of the acoustic signal by suppressing the components which are asynchronous. Based on the root mean square (RMS) values of CWT coefficients, the effects of biodiesel fractions and operating conditions (speed and load) on combustion process and engine dynamics were investigated. The result leads to the potential of airborne acoustic measurements and analysis for engine condition monitoring and fuel quality evaluation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
VanderNoot, Victoria A.; Haroldsen, Brent L.; Renzi, Ronald F.
2010-03-01
In a multiyear research agreement with Tenix Investments Pty. Ltd., Sandia has been developing field deployable technologies for detection of biotoxins in water supply systems. The unattended water sensor or UWS employs microfluidic chip based gel electrophoresis for monitoring biological analytes in a small integrated sensor platform. This instrument collects, prepares, and analyzes water samples in an automated manner. Sample analysis is done using the {mu}ChemLab{trademark} analysis module. This report uses analysis results of two datasets collected using the UWS to estimate performance of the device. The first dataset is made up of samples containing ricin at varying concentrations andmore » is used for assessing instrument response and detection probability. The second dataset is comprised of analyses of water samples collected at a water utility which are used to assess the false positive probability. The analyses of the two sets are used to estimate the Receiver Operating Characteristic or ROC curves for the device at one set of operational and detection algorithm parameters. For these parameters and based on a statistical estimate, the ricin probability of detection is about 0.9 at a concentration of 5 nM for a false positive probability of 1 x 10{sup -6}.« less
First Annual Report: NASA-ONERA Collaboration on Human Factors in Aviation Accidents and Incidents
NASA Technical Reports Server (NTRS)
Srivastava, Ashok; Fabiani, Patrick
2012-01-01
This is the first annual report jointly prepared by NASA and ONERA on the work performed under the agreement to collaborate on a study of the human factors entailed in aviation accidents and incidents particularly focused on consequences of decreases in human performance associated with fatigue. The objective of this Agreement is to generate reliable, automated procedures that improve understanding of the levels and characteristics of flight-crew fatigue factors whose confluence will likely result in unacceptable crew performance. This study entails the analyses of numerical and textual data collected during operational flights. NASA and ONERA are collaborating on the development and assessment of automated capabilities for extracting operationally significant information from very large, diverse (textual and numerical) databases much larger than can be handled practically by human experts. This report presents the approach that is currently expected to be used in processing and analyzing the data for identifying decrements in aircraft performance and examining their relationships to decrements in crewmember performance due to fatigue. The decisions on the approach were based on samples of both the numerical and textual data that will be collected during the four studies planned under the Human Factors Monitoring Program (HFMP). Results of preliminary analyses of these sample data are presented in this report.
Rollinson, Andrew N; Williams, Orla
2016-05-01
Samples of torrefied wood pellet produced by low-temperature microwave pyrolysis were tested through a series of experiments relevant to present and near future waste to energy conversion technologies. Operational performance was assessed using a modern small-scale downdraft gasifier. Owing to the pellet's shape and surface hardness, excellent flow characteristics were observed. The torrefied pellet had a high energy density, and although a beneficial property, this highlighted the present inflexibility of downdraft gasifiers in respect of feedstock tolerance due to the inability to contain very high temperatures inside the reactor during operation. Analyses indicated that the torrefaction process had not significantly altered inherent kinetic properties to a great extent; however, both activation energy and pre-exponential factor were slightly higher than virgin biomass from which the pellet was derived. Thermogravimetric analysis-derived reaction kinetics (CO2 gasification), bomb calorimetry, proximate and ultimate analyses, and the Bond Work Index grindability test provided a more comprehensive characterization of the torrefied pellet's suitability as a fuel for gasification and also other combustion applications. It exhibited significant improvements in grindability energy demand and particle size control compared to other non-treated and thermally treated biomass pellets, along with a high calorific value, and excellent resistance to water.
Rollinson, Andrew N.; Williams, Orla
2016-01-01
Samples of torrefied wood pellet produced by low-temperature microwave pyrolysis were tested through a series of experiments relevant to present and near future waste to energy conversion technologies. Operational performance was assessed using a modern small-scale downdraft gasifier. Owing to the pellet's shape and surface hardness, excellent flow characteristics were observed. The torrefied pellet had a high energy density, and although a beneficial property, this highlighted the present inflexibility of downdraft gasifiers in respect of feedstock tolerance due to the inability to contain very high temperatures inside the reactor during operation. Analyses indicated that the torrefaction process had not significantly altered inherent kinetic properties to a great extent; however, both activation energy and pre-exponential factor were slightly higher than virgin biomass from which the pellet was derived. Thermogravimetric analysis-derived reaction kinetics (CO2 gasification), bomb calorimetry, proximate and ultimate analyses, and the Bond Work Index grindability test provided a more comprehensive characterization of the torrefied pellet's suitability as a fuel for gasification and also other combustion applications. It exhibited significant improvements in grindability energy demand and particle size control compared to other non-treated and thermally treated biomass pellets, along with a high calorific value, and excellent resistance to water. PMID:27293776
Using Meta-analyses for Comparative Effectiveness Research
Ruppar, Todd M.; Phillips, Lorraine J.; Chase, Jo-Ana D.
2012-01-01
Comparative effectiveness research seeks to identify the most effective interventions for particular patient populations. Meta-analysis is an especially valuable form of comparative effectiveness research because it emphasizes the magnitude of intervention effects rather than relying on tests of statistical significance among primary studies. Overall effects can be calculated for diverse clinical and patient-centered variables to determine the outcome patterns. Moderator analyses compare intervention characteristics among primary studies by determining if effect sizes vary among studies with different intervention characteristics. Intervention effectiveness can be linked to patient characteristics to provide evidence for patient-centered care. Moderator analyses often answer questions never posed by primary studies because neither multiple intervention characteristics nor populations are compared in single primary studies. Thus meta-analyses provide unique contributions to knowledge. Although meta-analysis is a powerful comparative effectiveness strategy, methodological challenges and limitations in primary research must be acknowledged to interpret findings. PMID:22789450
Operational Characteristics of an Accelerator Driven Fissile Solution System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kimpland, Robert Herbert
Operational characteristics represent the set of responses that a nuclear system exhibits during normal operation. Operators rely on this behavior to assess the status of the system and to predict the consequences of off-normal events. These characteristics largely refer to the relationship between power and system operating conditions. The static and dynamic behavior of a chain-reacting system, operating at sufficient power, is primarily governed by reactivity effects. The science of reactor physics has identified and evaluated a number of such effects, including Doppler broadening and shifts in the thermal neutron spectrum. Often these reactivity effects are quantified in the formmore » of feedback coefficients that serve as coupling coefficients relating the neutron population and the physical mechanisms that drive reactivity effects, such as fissile material temperature and density changes. The operational characteristics of such nuclear systems usually manifest themselves when perturbations between system power (neutron population) and system operating conditions arise. Successful operation of such systems requires the establishment of steady equilibrium conditions. However, prior to obtaining the desired equilibrium (steady-state) conditions, an approach from zero-power (startup) must occur. This operational regime may possess certain limiting system conditions that must be maintained to achieve effective startup. Once steady-state is achieved, a key characteristic of this operational regime is the level of stability that the system possesses. Finally, a third operational regime, shutdown, may also possess limiting conditions of operation that must be maintained. This report documents the operational characteristics of a “generic” Accelerator Driven Fissile Solution (ADFS) system during the various operational regimes of startup, steady-state operation, and shutdown. Typical time-dependent behavior for each operational regime will be illustrated, and key system parameters, such as response times, will be quantified. A generalized linear systems analysis of steady-state operations will be performed to evaluate the level of stability of ADFS systems. This information should provide a basic understanding of typical ADFS system operational behavior, and facilitate the development of monitoring procedures and operator aids.« less
Multidisciplinary team simulation for the operating theatre: a review of the literature.
Tan, Shaw Boon; Pena, Guilherme; Altree, Meryl; Maddern, Guy J
2014-01-01
Analyses of adverse events inside the operating theatre has demonstrated that many errors are caused by failure in non-technical skills and teamwork. While simulation has been used successfully for teaching and improving technical skills, more recently, multidisciplinary simulation has been used for training team skills. We hypothesized that this type of training is feasible and improves team skills in the operating theatre. A systematic search of the literature for studies describing true multidisciplinary operating theatre team simulation was conducted in November and December 2012. We looked at the characteristics and outcomes of the team simulation programmes. 1636 articles were initially retrieved. Utilizing a stepwise evaluation process, 26 articles were included in the review. The studies reveal that multidisciplinary operating theatre simulation has been used to provide training in technical and non-technical skills, to help implement new techniques and technologies, and to identify latent weaknesses within a health system. Most of the studies included are descriptions of training programmes with a low level of evidence. No randomized control trial was identified. Participants' reactions to the training programme were positive in all studies; however, none of them could objectively demonstrate that skills acquired from simulation are transferred to the operating theatre or show a demonstrable benefit in patient outcomes. Multidisciplinary operating room team simulation is feasible and widely accepted by participants. More studies are required to assess the impact of this type of training on operative performance and patient safety. © 2013 Royal Australasian College of Surgeons.
De Pasquale, Gabriella; Bonassin Tempesta, Francesca; Lopes, Bruno Santos; Babic, Daniela; Oxenius, Angela; Seeliger, Theresa; Gruner, Christiane; Tanner, Felix C; Biaggi, Patric; Attenhofer Jost, Christine; Greutmann, Matthias
2017-05-01
To determine the prevalence of baffle leaks in adults after atrial switch operations for transposition of the great arteries, as these may predispose to paradoxical embolic events, particularly in patients with transvenous pacemaker or defibrillator leads. We routinely perform contrast echocardiography with agitated saline in all patients after atrial switch operations. For this study, we analysed patients who had saline contrast echocardiography between 2010 and 2012. The presence of baffle leaks and the severity of right-to-left shunting were assessed. We compared baseline characteristics and oxygen saturation at rest and during exercise between patients with and without baffle leaks. A total of 65 patients (56 Senning and 9 Mustard repair) without previously known baffle leaks were included (mean age 32 ± 8 years, 77% males). Right-to-left shunting was identified in 42 patients (65%) and occurred without provocation manoeuvres in 88%. There were no differences in baseline characteristics, echocardiographic findings, or exercise capacity between patients with and without baffle leaks, except for lower oxygen saturation at peak exercise in those with baffle leaks (29% had oxygen saturations below 90% at peak exercise compared to none without baffle leaks, P = 0.011). Four patients with baffle leaks had previous implantation of transvenous pacemaker leads; one of them had suffered a stroke. Two other patients with baffle leaks had a history of potential embolic stroke. Because of the high prevalence of baffle leaks in adults after atrial switch operations, we propose routine screening with agitated saline contrast, particularly prior to implantation of transvenous pacemaker or defibrillator leads. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.
Cypel, Yasmin S; Hamlett-Berry, Kim; Barth, Shannon K; Christofferson, Dana E; Davey, Victoria J; Eber, Stephanie; Schneiderman, Aaron I; Bossarte, Robert M
2016-09-01
We examined the sociodemographic, military, and health characteristics of current cigarette smokers, former smokers, and nonsmokers among Operation Enduring Freedom (OEF) / Operation Iraqi Freedom (OIF) veterans and estimated smoking prevalence to better understand cigarette use in this population. We analyzed data from the US Department of Veterans Affairs (VA) 2009-2011 National Health Study for a New Generation of US Veterans. On the basis of a stratified random sample of 60 000 OEF/OIF veterans, we sought responses to a 72-item questionnaire via mail, telephone, or Internet. Cigarette smoking status was based on self-reported cigarette use in the past year. We used multinomial logistic regression to evaluate associations between smoking status and sociodemographic, military, and health characteristics. Among 19 911 veterans who provided information on cigarette smoking, 5581 were current smokers (weighted percentage: 32.5%, 95% confidence interval [CI]: 31.7-33.2). Current smokers were more likely than nonsmokers or former smokers to be younger, to have less education or income, to be separated/divorced or never married/single, and to have served on active duty or in the army. Comparing current smokers and nonsmokers, some significant associations from adjusted analyses included the following: having a Mental Component Summary score (a measure of overall mental health) above the mean of the US population relative to below the mean (adjusted odds ratio [aOR] = 0.81, 95% CI: 0.73-0.90); having physician-diagnosed depression (aOR = 1.52, 95% CI: 1.33-1.74), respiratory conditions (aOR = 1.16, 95% CI: 1.04-1.30), or repeated seizures/blackouts/convulsions (aOR = 1.80, 95% CI: 1.22-2.67); heavy alcohol use vs never use (aOR = 5.49, 95% CI: 4.57-6.59); a poor vs excellent perception of overall health (aOR = 3.79, 95% CI: 2.60-5.52); and being deployed vs nondeployed (aOR = 0.87, 95% CI: 0.78-0.96). Using health care services from the VA protected against current smoking. Mental and physical health, substance use, and military service characteristics shape cigarette-smoking patterns in OEF/OIF veterans.
NASA Astrophysics Data System (ADS)
Chaczykowski, Maciej
2016-06-01
After having described the models for the organic Rankine cycle (ORC) equipment in the first part of this paper, this second part provides an example that demonstrates the performance of different ORC systems in the energy recovery application in a gas compressor station. The application shows certain specific characteristics, i.e. relatively large scale of the system, high exhaust gas temperature, low ambient temperature operation, and incorporation of an air-cooled condenser, as an effect of the localization in a compressor station plant. Screening of 17 organic fluids, mostly alkanes, was carried out and resulted in a selection of best performing fluids for each cycle configuration, among which benzene, acetone and heptane showed highest energy recovery potential in supercritical cycles, while benzene, toluene and cyclohexane in subcritical cycles. Calculation results indicate that a maximum of 10.4 MW of shaft power can be obtained from the exhaust gases of a 25 MW compressor driver by the use of benzene as a working fluid in the supercritical cycle with heat recuperation. In relation to the particular transmission system analysed in the study, it appears that the regenerative subcritical cycle with toluene as a working fluid presents the best thermodynamic characteristics, however, require some attention insofar as operational conditions are concerned.
Bara, Tiago S; Farias, Antonio C; Felden, Erico PG; Cordeiro, Mara L
2018-01-01
Background Autism spectrum disorder (ASD) is a neurodevelopmental disorder characterized by social, behavioral, and communication impairments with an estimated prevalence of 1 in 68 school-aged children. There is a need for objective and easily applicable instruments for early identification of autistic children to enable initiation of early interventions during a very sensitive period of brain development and, consequently, optimize prognosis. Here, we tested the utility of the Child Behavior Checklist (CBCL) and the Caregiver-Teacher’s Report Form (C-TRF) scales for assessing ASD in Brazil, where ASD screening research is emergent. Subjects and methods A total of 70 children (2–5 years old, both sexes) were enrolled, including an ASD group (n=39) and a non-ASD control group (n=31). The preschool versions of the CBCL and C-TRF were applied. The CBCL and C-TRF results were compared between the ASD and non-ASD control groups with Mann–Whitney U tests and receiver operating characteristic analyses. Results The CBCL and C-TRF were found to have moderate accuracy for the dimensions withdrawn and autism spectrum problems, and to correlate with each other. Conclusion The CBCL and C-TRF may aid in early ASD detection. PMID:29343961
Asano, Junichi; Hirakawa, Akihiro
2017-01-01
The Cox proportional hazards cure model is a survival model incorporating a cure rate with the assumption that the population contains both uncured and cured individuals. It contains a logistic regression for the cure rate, and a Cox regression to estimate the hazard for uncured patients. A single predictive model for both the cure and hazard can be developed by using a cure model that simultaneously predicts the cure rate and hazards for uncured patients; however, model selection is a challenge because of the lack of a measure for quantifying the predictive accuracy of a cure model. Recently, we developed an area under the receiver operating characteristic curve (AUC) for determining the cure rate in a cure model (Asano et al., 2014), but the hazards measure for uncured patients was not resolved. In this article, we propose novel C-statistics that are weighted by the patients' cure status (i.e., cured, uncured, or censored cases) for the cure model. The operating characteristics of the proposed C-statistics and their confidence interval were examined by simulation analyses. We also illustrate methods for predictive model selection and for further interpretation of variables using the proposed AUCs and C-statistics via application to breast cancer data.
Oyabu, Chikako; Ushigome, Emi; Matsumoto, Shinobu; Tanaka, Toru; Hasegawa, Goji; Nakamura, Naoto; Ohnishi, Masayoshi; Tsunoda, Sei; Ushigome, Hidetaka; Yokota, Isao; Tanaka, Muhei; Asano, Mai; Yamazaki, Masahiro; Fukui, Michiaki
2017-11-01
Maximum home systolic blood pressure has been shown to predict target organ damage. We aimed to clarify the association between maximum home systolic blood pressure and urine albumin to creatinine ratio, an indicator of early-phase diabetic nephropathy in patients with type 2 diabetes. In 1040 patients, we assessed the relationship of mean or maximum home systolic blood pressure and urine albumin to creatinine ratio, and compared the area under the receiver operating characteristic curve of mean or maximum home systolic blood pressure for diabetic nephropathy (urine albumin to creatinine ratio ⩾30 mg/g Cr). Multivariate linear regression analyses indicated that mean morning systolic blood pressure ( β = 0.010, p < 0.001) and maximum morning systolic blood pressure ( β = 0.008, p < 0.001) were significantly associated with urine albumin to creatinine ratio. Area under the receiver operating characteristic curve (95% confidence interval) for diabetic nephropathy in mean and maximum morning systolic blood pressure was 0.667 (0.634-0.700; p < 0.001) and 0.671 (0.638-0.703; p < 0.001), respectively. Maximum home systolic blood pressure, as well as mean home systolic blood pressure, was significantly associated with diabetic nephropathy in patients with type 2 diabetes.
Value of MR histogram analyses for prediction of microvascular invasion of hepatocellular carcinoma
Huang, Ya-Qin; Liang, He-Yue; Yang, Zhao-Xia; Ding, Ying; Zeng, Meng-Su; Rao, Sheng-Xiang
2016-01-01
Abstract The objective is to explore the value of preoperative magnetic resonance (MR) histogram analyses in predicting microvascular invasion (MVI) of hepatocellular carcinoma (HCC). Fifty-one patients with histologically confirmed HCC who underwent diffusion-weighted and contrast-enhanced MR imaging were included. Histogram analyses were performed and mean, variance, skewness, kurtosis, 1th, 10th, 50th, 90th, and 99th percentiles were derived. Quantitative histogram parameters were compared between HCCs with and without MVI. Receiver operating characteristics (ROC) analyses were generated to compare the diagnostic performance of tumor size, histogram analyses of apparent diffusion coefficient (ADC) maps, and MR enhancement. The mean, 1th, 10th, and 50th percentiles of ADC maps, and the mean, variance. 1th, 10th, 50th, 90th, and 99th percentiles of the portal venous phase (PVP) images were significantly different between the groups with and without MVI (P <0.05), with area under the ROC curves (AUCs) of 0.66 to 0.74 for ADC and 0.76 to 0.88 for PVP. The largest AUC of PVP (1th percentile) showed significantly higher accuracy compared with that of arterial phase (AP) or tumor size (P <0.001). MR histogram analyses—in particular for 1th percentile for PVP images—held promise for prediction of MVI of HCC. PMID:27368028
Carbon deposition model for oxygen-hydrocarbon combustion, volume 1
NASA Technical Reports Server (NTRS)
Hernandez, R.; Ito, J. I.; Niiya, K. Y.
1987-01-01
Presented are details of the design, fabrication, and testing of subscale hardware used in the evaluation of carbon deposition characteristics of liquid oxygen and three hydrocarbon fuels for both main chamber and preburner/gas generator operating conditions. In main chamber conditions, the deposition of carbon on the combustion chamber wall was investigated at mixture ratios of 2.0 to 4.0 and at pressures of 1000 to 1500 psia. No carbon deposition on the chamber walls was detected at these main chamber mixture ratios. In preburner/gas generator operating conditions, the deposition of carbon on the turbine simulator tubes was evaluated at mixture ratios of 0.20 to 0.60 and at chamber pressures of 720 to 1650 psia. The results of the tests showed carbon deposition rate to be a strong function of mixture ratio and a weak function of chamber pressure. Further analyses evaluated the operational consequences of carbon deposition on preburner/gas generator performance. The report is in two volumes, of which this is Volume 1 covering the main body of the report plus Appendixes A through D.
An experimental investigation of alternative propellants for the helicon double layer thruster
NASA Astrophysics Data System (ADS)
Charles, C.; Boswell, R. W.; Laine, R.; MacLellan, P.
2008-09-01
Ion energy distribution functions are measured using a retarding field energy analyser located 7.5 cm downstream of a helicon double layer plasma source, respectively, operating with four molecular gases: nitrogen (N2), methane (CH4), ammonia (NH3) and nitrous oxide (N2O). For radiofrequency powers of a few hundred watts, and a magnetic field diverging from about 0.013 T (130 G) in the source to about 0.001 T (10 G) in the exhaust, an ion beam is detected for each propellant over a very similar operating pressure range (~0.023 Pa (0.17 mTorr) to ~0.267 Pa (2 mTorr)), as a result of spontaneous electric double layer formation near the exit of the plasma source. The characteristics of the ion beam versus operating pressure closely follow those previously obtained in argon, xenon and hydrogen. The ion beam exhaust velocity in space is found to be in the 17-19 km s-1 range in N2, 21-27 km s-1 range in CH4 and NH3 and 14-16 km s-1 range in N2O.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wegemar, B.
Operating experiences from the Forsmark 3 and Oskarshamn 3 BWRs have been evaluated during the first two cycles of their operation. The objective of this work was to determine the influence on water chemistry quality and radiation field buildup from the special design characteristics of these plants. Important differences from older ASEA-ATOM BWRs include the concept of forward pumped high pressure heater drains, magnetic filtration of high pressure drains and use of more erosion-resistant materials in turbine components. Data obtained from water radiochemistry measurements, shutdown dose rates and gamma scanning surveys, fuel deposit analyses and occuptional exposure statistics have beenmore » used in order to enable a comparsion to older ASEA-ATOM BWRs. At the end of the second cycles, satisfactory feedwater quality was reported in both plants. Radiation levels around components in the primary systems are higher in Forsmark 3 and Oskarshamn 3 as compared to other plants. This is in agreement with reactor water activities, fuel deposits and gamma scanning surveys, indicating somewhat higher amounts of cobalt-60 and cobalt-58. However, in both plants occupational exposures were low during the first two years of operation.« less
Feasibility study for the implementation of NASTRAN on the ILLIAC 4 parallel processor
NASA Technical Reports Server (NTRS)
Field, E. I.
1975-01-01
The ILLIAC IV, a fourth generation multiprocessor using parallel processing hardware concepts, is operational at Moffett Field, California. Its capability to excel at matrix manipulation, makes the ILLIAC well suited for performing structural analyses using the finite element displacement method. The feasibility of modifying the NASTRAN (NASA structural analysis) computer program to make effective use of the ILLIAC IV was investigated. The characteristics are summarized of the ILLIAC and the ARPANET, a telecommunications network which spans the continent making the ILLIAC accessible to nearly all major industrial centers in the United States. Two distinct approaches are studied: retaining NASTRAN as it now operates on many of the host computers of the ARPANET to process the input and output while using the ILLIAC only for the major computational tasks, and installing NASTRAN to operate entirely in the ILLIAC environment. Though both alternatives offer similar and significant increases in computational speed over modern third generation processors, the full installation of NASTRAN on the ILLIAC is recommended. Specifications are presented for performing that task with manpower estimates and schedules to correspond.
14 CFR 23.253 - High speed characteristics.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false High speed characteristics. 23.253 Section... Requirements § 23.253 High speed characteristics. If a maximum operating speed VMO/MMO is established under § 23.1505(c), the following speed increase and recovery characteristics must be met: (a) Operating...
14 CFR 23.253 - High speed characteristics.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false High speed characteristics. 23.253 Section... Requirements § 23.253 High speed characteristics. If a maximum operating speed VMO/MMO is established under § 23.1505(c), the following speed increase and recovery characteristics must be met: (a) Operating...
Magyar, Caroline I; Pandolfi, Vincent; Dill, Charles A
2012-02-01
This study investigated the psychometric properties of the Social Communication Questionnaire (SCQ) in a sample of children with Down syndrome (DS), many of whom had a co-occurring autism spectrum disorder (ASD). The SCQ is a widely used ASD screening measure; however, its measurement properties have not been comprehensively evaluated specifically in children with DS, a group that seems to be at higher risk for an ASD. Exploratory and confirmatory factor analyses, scale reliability, convergent and discriminant correlations, significance tests between groups of children with DS and DS + ASD, and diagnostic accuracy analyses were conducted. Factor analyses identified 2 reliable factors that we labeled Social-Communication and Stereotyped Behavior and Unusual Interests. Pearson correlations with Autism Diagnostic Interview-Revised subscales indicated support for the SCQ's convergent validity and some support for the discriminant validity of the factor-based scales. Significance tests and receiver operating characteristic analyses indicated that children with DS + ASD obtained significantly higher SCQ factor-based and total scores than children with DS alone, and that the SCQ Total Score evidenced good sensitivity and adequate specificity. Results indicated initial psychometric support for the SCQ as an ASD screening measure in children with DS. The SCQ should be considered as part of a multimethod evaluation when screening children with DS.
Measurement and Modeling of Job Stress of Electric Overhead Traveling Crane Operators
Krishna, Obilisetty B.; Maiti, Jhareswar; Ray, Pradip K.; Samanta, Biswajit; Mandal, Saptarshi; Sarkar, Sobhan
2015-01-01
Background In this study, the measurement of job stress of electric overhead traveling crane operators and quantification of the effects of operator and workplace characteristics on job stress were assessed. Methods Job stress was measured on five subscales: employee empowerment, role overload, role ambiguity, rule violation, and job hazard. The characteristics of the operators that were studied were age, experience, body weight, and body height. The workplace characteristics considered were hours of exposure, cabin type, cabin feature, and crane height. The proposed methodology included administration of a questionnaire survey to 76 electric overhead traveling crane operators followed by analysis using analysis of variance and a classification and regression tree. Results The key findings were: (1) the five subscales can be used to measure job stress; (2) employee empowerment was the most significant factor followed by the role overload; (3) workplace characteristics contributed more towards job stress than operator's characteristics; and (4) of the workplace characteristics, crane height was the major contributor. Conclusion The issues related to crane height and cabin feature can be fixed by providing engineering or foolproof solutions than relying on interventions related to the demographic factors. PMID:26929839
[PROGNOSTIC MODELS IN MODERN MANAGEMENT OF VULVAR CANCER].
Tsvetkov, Ch; Gorchev, G; Tomov, S; Nikolova, M; Genchev, G
2016-01-01
The aim of the research was to evaluate and analyse prognosis and prognostic factors in patients with squamous cell vulvar carcinoma after primary surgery with individual approach applied during the course of treatment. In the period between January 2000 and July 2010, 113 patients with squamous cell carcinoma of the vulva were diagnosed and operated on at Gynecologic Oncology Clinic of Medical University, Pleven. All the patients were monitored at the same clinic. Individual approach was applied to each patient and whenever it was possible, more conservative operative techniques were applied. The probable clinicopathological characteristics influencing the overall survival and recurrence free survival were analyzed. Univariate statistical analysis and Cox regression analysis were made in order to evaluate the characteristics, which were statistically significant for overall survival and survival without recurrence. A multivariate logistic regression analysis (Forward Wald procedure) was applied to evaluate the combined influence of the significant factors. While performing the multivariate analysis, the synergic effect of the independent prognostic factors of both kinds of survivals was also evaluated. Approaching individually each patient, we applied the following operative techniques: 1. Deep total radical vulvectomy with separate incisions for lymph dissection (LD) or without dissection--68 (60.18 %) patients. 2. En-bloc vulvectomy with bilateral LD without vulva reconstruction--10 (8.85%) 3. Modified radical vulvactomy (hemivulvectomy, patial vulvactomy)--25 (22.02%). 4. wide-local excision--3 (2.65%). 5. Simple (total /partial) vulvectomy--5 (4.43%) patients. 6. En-bloc resection with reconstruction--2 (1.77%) After a thorough analysis of the overall survival and recurrence free survival, we made the conclusion that the relapse occurrence and clinical stage of FIGO were independent prognostic factors for overall survival and the independent prognostic factors for recurrence free survival were: metastatic inguinal nodes (unilateral or bilateral), tumor size (above or below 3 cm) and lymphovascular space invasion. On the basis of these results we created two prognostic models: 1. A prognostic model of overall survival 2. A prognostic model for survival without recurrence. Following the surgical staging of the disease, were able to gather and analyse important clinicopathological indexes, which gave us the opportunity to form prognostic groups for overall survival and recurrence-free survival.
Estimates of streamflow characteristics for selected small streams, Baker River basin, Washington
Williams, John R.
1987-01-01
Regression equations were used to estimate streamflow characteristics at eight ungaged sites on small streams in the Baker River basin in the North Cascade Mountains, Washington, that could be suitable for run-of-the-river hydropower development. The regression equations were obtained by relating known streamflow characteristics at 25 gaging stations in nearby basins to several physical and climatic variables that could be easily measured in gaged or ungaged basins. The known streamflow characteristics were mean annual flows, 1-, 3-, and 7-day low flows and high flows, mean monthly flows, and flow duration. Drainage area and mean annual precipitation were not the most significant variables in all the regression equations. Variance in the low flows and the summer mean monthly flows was reduced by including an index of glacierized area within the basin as a third variable. Standard errors of estimate of the regression equations ranged from 25 to 88%, and the largest errors were associated with the low flow characteristics. Discharge measurements made at the eight sites near midmonth each month during 1981 were used to estimate monthly mean flows at the sites for that period. These measurements also were correlated with concurrent daily mean flows from eight operating gaging stations. The correlations provided estimates of mean monthly flows that compared reasonably well with those estimated by the regression analyses. (Author 's abstract)
Flight Studies of Problems Pertinent to High-Speed Operation of Jet Transports
NASA Technical Reports Server (NTRS)
Butchart, Stanley P.; Fischel, Jack; Tremant, Robert A.; Robinson, Glenn H.
1959-01-01
A flight investigation was made to assess the potential operational problems of jet transports in the transonic cruise range. In this study a large multiengine jet airplane having geometric characteristics fairly representative of the jet transport was used; however, in order to ensure general applicability of the results, the aerodynamic characteristics of the test airplane were varied to simulate a variety of jet- transport airplanes. Some of the specific areas investigated include: (1) an overall evaluation of longitudinal stability and control characteristics at transonic speeds, with an assessment of pitch-up characteristics, (2) the effect of buffeting on airplane operational speeds and maneuvering, (3) the desirable lateral-directional damping characteristics, (4) the desirable lateral-control characteristics, (5) an assessment of over-speed and speed-spread requirements, including the upset maneuver, and (6) an assessment of techniques and airplane characteristics for rapid descent and slow-down. The results presented include pilots' evaluation of the various problem areas and specific recommendations for possible improvement of jet-transport operations in the cruising speed range.
Study of operator's information in the course of complicated and combined activity
NASA Astrophysics Data System (ADS)
Krylova, N. V.; Bokovikov, A. K.
1982-08-01
Speech characteristics of operators performing control and observation operations, Information reception, transmission and processing, and decision making when exposed to the real stress of parachute jumps were investigated. Form and content speech characteristics whose variations reflect the level of operators adaptation to stressful activities are reported.
NASA Technical Reports Server (NTRS)
Meston, R. D.; Schall, M. R., Jr.; Brockman, C. L.; Bender, W. H.
1972-01-01
All analyses and tradeoffs conducted to establish the MSS operations and crew activities are discussed. The missions and subsystem integrated analyses that were completed to assure compatibility of program elements and consistency with program objectives are presented.
14 CFR 33.51 - Operation test.
Code of Federal Regulations, 2012 CFR
2012-01-01
... STANDARDS: AIRCRAFT ENGINES Block Tests; Reciprocating Aircraft Engines § 33.51 Operation test. The... characteristics, starting, idling, acceleration, overspeeding, functioning of propeller and ignition, and any other operational characteristic of the engine. If the engine incorporates a multispeed supercharger...
14 CFR 33.51 - Operation test.
Code of Federal Regulations, 2011 CFR
2011-01-01
... STANDARDS: AIRCRAFT ENGINES Block Tests; Reciprocating Aircraft Engines § 33.51 Operation test. The... characteristics, starting, idling, acceleration, overspeeding, functioning of propeller and ignition, and any other operational characteristic of the engine. If the engine incorporates a multispeed supercharger...
Onboard Navigation Systems Characteristics
NASA Technical Reports Server (NTRS)
1979-01-01
The space shuttle onboard navigation systems characteristics are described. A standard source of equations and numerical data for use in error analyses and mission simulations related to space shuttle development is reported. The sensor characteristics described are used for shuttle onboard navigation performance assessment. The use of complete models in the studies depend on the analyses to be performed, the capabilities of the computer programs, and the availability of computer resources.
Challenges and solutions to pre- and post-randomization subgroup analyses.
Desai, Manisha; Pieper, Karen S; Mahaffey, Ken
2014-01-01
Subgroup analyses are commonly performed in the clinical trial setting with the purpose of illustrating that the treatment effect was consistent across different patient characteristics or identifying characteristics that should be targeted for treatment. There are statistical issues involved in performing subgroup analyses, however. These have been given considerable attention in the literature for analyses where subgroups are defined by a pre-randomization feature. Although subgroup analyses are often performed with subgroups defined by a post-randomization feature--including analyses that estimate the treatment effect among compliers--discussion of these analyses has been neglected in the clinical literature. Such analyses pose a high risk of presenting biased descriptions of treatment effects. We summarize the challenges of doing all types of subgroup analyses described in the literature. In particular, we emphasize issues with post-randomization subgroup analyses. Finally, we provide guidelines on how to proceed across the spectrum of subgroup analyses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caniato, Marco, E-mail: marcocaniato@gmail.com; Vaccari, Mentore, E-mail: mentore.vaccari@unibs.it; Visvanathan, Chettiyappan, E-mail: visu@ait.ac.th
Highlights: • Assessment of infectious waste management in Bangkok, in particular incineration. • Integration of social network and stakeholder analysis assessment methods. • Assessment of stakeholder characteristics, role, interaction and communication. • Interviewees self-evaluate their own characteristics and the system. • Non-technical aspects are important for system acceptability, and sustainability. - Abstract: Assessing the strengths and weaknesses of a solid waste management scheme requires an accurate analysis and integration of several determining features. In addition to the technical aspects, any such system shows a complex interaction of actors with varying stakes, decision-making power and influence, as well as a favourablemore » or disabling environment. When capitalizing on the knowledge and experience from a specific case, it is also crucial that experts do not “forget” or underestimate the importance of such social determinants and that they are familiar with the methods and tools to assess them. Social network analysis (SNA) and stakeholder analysis (SA) methods can be successfully applied to better understand actors’ role and actions, analyse driving forces and existing coordination among stakeholders, as well as identify bottlenecks in communication which affect daily operations or strategic planning for the future way forward. SNA and SA, appropriately adjusted for a certain system, can provide a useful integration to methods by assessing other aspects to ensure a comprehensive picture of the situation. This paper describes how to integrate SNA and SA in order to survey a solid waste management system. This paper presents the results of an analysis of On-Nuch infectious waste incinerator in Bangkok, Thailand. Stakeholders were interviewed and asked to prioritize characteristics and relationships which they consider particularly important for system development and success of the scheme. In such a way, a large quantity of information about organization, communication between stakeholders and their perception about operation, environmental and health impact, and potential alternatives for the system was collected in a systematic way. The survey results suggest that stakeholders are generally satisfied with the system operation, though communication should be improved. Moreover, stakeholders should be strategically more involved in system development planning, according to their characteristics, to prevent negative reactions.« less
ERIC Educational Resources Information Center
Samejima, Fumiko
A method is proposed that increases the accuracies of estimation of the operating characteristics of discrete item responses, especially when the true operating characteristic is represented by a steep curve, and also at the lower and upper ends of the ability distribution where the estimation tends to be inaccurate because of the smaller number…
Manivannan, Bhavani; Gowda, Deepak; Bulagonda, Pradeep; Rao, Abhishek; Raman, Sai Suguna; Natarajan, Shanmuga Vadivoo
2018-04-01
We evaluated the Surveillance of Surgical Site Infection (SSI), Auditing, and Feedback (SAF) effect on the rate of compliance with an SSI care bundle and measured its effectiveness in reducing the SSI rate. A prospective cohort study from January 2014 to December 2016 was classified into three phases: pre-SAF, early-SAF, and late-SAF. Pre-operative baseline characteristics of 24,677 patients who underwent orthopedic, cardiovascular thoracic surgery (CTVS) or urologic operations were recorded. Univariable analyses of the SSI rates in the pre-SAF and post-SAF phases were performed. Percentage compliance and non-compliance with each care component were calculated. Correlation between reduction in the SSI rate and increase in compliance with the pre-operative, peri-operative, and post-operative care-bundle components was performed using the Spearman test. There was a significant decrease in the SSI rate in orthopedic procedures that involved surgical implantation and in mitral valve/aortic valve (MVR/AVR) cardiac operations, with a relative risk (RR) ratio of 0.19 (95% confidence interval [CI] 0.12-0.31) and 0.08 (95% CI 0.03-0.22), respectively. The SSI rate was inversely correlated with the rate of compliance with pre-operative (r = -0.738; p = 0.037), peri-operative (r = - 0.802; p = 0.017), and post-operative (r = -0.762; p = 0.028) care bundles. Implementation of the Surveillance of SSI, Auditing, and Feedback bundle had a profound beneficial effect on the SSI rate, thereby reducing healthcare costs and improving patient quality of life.
Telling, Mark T F; Campbell, Stuart I; Engberg, Dennis; Martín Y Marero, David; Andersen, Ken H
2016-03-21
Correction for 'Spectroscopic characteristics of the OSIRIS near-backscattering crystal analyser spectrometer on the ISIS pulsed neutron source' by Mark T. F. Telling et al., Phys. Chem. Chem. Phys., 2005, 7, 1255-1261.
CMG-Biotools, a Free Workbench for Basic Comparative Microbial Genomics
Vesth, Tammi; Lagesen, Karin; Acar, Öncel; Ussery, David
2013-01-01
Background Today, there are more than a hundred times as many sequenced prokaryotic genomes than were present in the year 2000. The economical sequencing of genomic DNA has facilitated a whole new approach to microbial genomics. The real power of genomics is manifested through comparative genomics that can reveal strain specific characteristics, diversity within species and many other aspects. However, comparative genomics is a field not easily entered into by scientists with few computational skills. The CMG-biotools package is designed for microbiologists with limited knowledge of computational analysis and can be used to perform a number of analyses and comparisons of genomic data. Results The CMG-biotools system presents a stand-alone interface for comparative microbial genomics. The package is a customized operating system, based on Xubuntu 10.10, available through the open source Ubuntu project. The system can be installed on a virtual computer, allowing the user to run the system alongside any other operating system. Source codes for all programs are provided under GNU license, which makes it possible to transfer the programs to other systems if so desired. We here demonstrate the package by comparing and analyzing the diversity within the class Negativicutes, represented by 31 genomes including 10 genera. The analyses include 16S rRNA phylogeny, basic DNA and codon statistics, proteome comparisons using BLAST and graphical analyses of DNA structures. Conclusion This paper shows the strength and diverse use of the CMG-biotools system. The system can be installed on a vide range of host operating systems and utilizes as much of the host computer as desired. It allows the user to compare multiple genomes, from various sources using standardized data formats and intuitive visualizations of results. The examples presented here clearly shows that users with limited computational experience can perform complicated analysis without much training. PMID:23577086
NASA Astrophysics Data System (ADS)
Yao, Qiming; Liu, Shuo; Liu, Yang
2018-05-01
An experimental design was used to study the vehicle operation characteristics of different ramp entrance conditions in underground road. With driving simulator, the experimental scenarios include left or right ramp with first, second and third service level, respectively, to collect vehicle speed, acceleration, lateral displacement and location information at the ramp entrance section. By using paired t-test and ANOVA, the influence factors of vehicle operating characteristics are studied. The result shows that effects of ramp layout and mainline traffic environment on vehicle operation characteristics are significant. The regression model of vehicle traveling distance on acceleration lane is established. Suggestions are made for ramp entrance design of underground road.
Mitra, Sanjana; Rachlis, Beth; Scheim, Ayden; Bardwell, Geoff; Rourke, Sean B; Kerr, Thomas
2017-07-14
Supervised injection services (SIS) have been shown to reduce the public- and individual-level harms associated with injection drug use. While SIS feasibility research has been conducted in large urban centres, little is known about the acceptability of these services among people who inject drugs (PWID) in mid-sized cities. We assessed the prevalence and correlates of willingness to use SIS as well as design and operational preferences among PWID in London, Canada. Between March and April 2016, peer research associates administered a cross-sectional survey to PWID in London. Socio-demographic characteristics, drug-use patterns, and behaviours associated with willingness to use SIS were estimated using bivariable and multivariable logistic regression models. Chi-square tests were used to compare characteristics with expected frequency of SIS use among those willing to use SIS. Design and operational preferences are also described. Of 197 PWID included in this analysis (median age, 39; interquartile range (IQR), 33-50; 38% female), 170 (86%) reported willingness to use SIS. In multivariable analyses, being female (adjusted odds ratio (AOR) 0.29; 95% confidence interval (CI) 0.11-0.75) was negatively associated with willingness to use, while public injecting in the last 6 months (AOR 2.76; 95% CI 1.00-7.62) was positively associated with willingness to use. Participants living in unstable housing, those injecting in public, and those injecting opioids and crystal methamphetamine daily reported higher expected frequency of SIS use (p < 0.05). A majority preferred private cubicles for injecting spaces and daytime operational hours, while just under half preferred PWID involved in service operations. High levels of willingness to use SIS were found among PWID in this setting, suggesting that these services may play a role in addressing the harms associated with injection drug use. To maximize the uptake of SIS, programme planners and policy makers should consider the effects of gender and views of PWID regarding SIS design and operational preferences.
The impact of improving teamwork on patient outcomes in surgery: A systematic review.
Sun, Rosa; Marshall, Dominic C; Sykes, Mark C; Maruthappu, Mahiben; Shalhoub, Joseph
2018-05-01
The aviation industry pioneered formalised crew training in order to improve safety and reduce consequences of non-technical error. This formalised training has been successfully adapted and used to in the field of surgery to improve post-operative patient outcomes. The need to implement teamwork training as an integral part of a surgical programme is increasingly being recognised. We aim to systematically review the impact of surgical teamwork training on post-operative outcomes. Two independent researchers systematically searched MEDLINE and Embase in accordance with PRISMA guidelines. Studies were screened and subjected to inclusion/exclusion criteria. Study characteristics and outcomes were reported and analysed. Our initial search identified 2720 articles. Following duplicate removal, title and abstract screening, 107 full text articles were analysed. Eight articles met our inclusion criteria. Overall, three articles supported a positive effect of good teamwork on post-operative patient outcomes. We identified key areas in study methodology that can be improved upon, including small cohort size, lack of unified training programme, and short training duration, should future studies be designed and implemented in this field. At present, there is insufficient evidence to support the hypothesis that teamwork training interventions improve patient outcomes. We believe that non-significant and conflicting results can be attributed to flaws in methodology and non-uniform training methods. With increasing amounts of evidence in this field, we predict a positive association between teamwork training and patient outcomes will come to light. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Interactive Webmap-Based Science Planning for BepiColombo
NASA Astrophysics Data System (ADS)
McAuliffe, J.; Martinez, S.; Ortiz de Landaluce, I.; de la Fuente, S.
2015-10-01
For BepiColombo, ESA's Mission to Mercury, we will build a web-based, map-based interface to the Science Planning System. This interface will allow the mission's science teams to visually define targets for observations and interactively specify what operations will make up the given observation. This will be a radical departure from previous ESA mission planning methods. Such an interface will rely heavily on GIS technologies. This interface will provide footprint coverage of all existing archived data for Mercury, including a set of built-in basemaps. This will allow the science teams to analyse their planned observations and operational constraints with relevant contextual information from their own instrument, other BepiColombo instruments or from previous missions. The interface will allow users to import and export data in commonly used GIS formats, such that it can be visualised together with the latest planning information (e.g. import custom basemaps) or analysed in other GIS software. The interface will work with an object-oriented concept of an observation that will be a key characteristic of the overall BepiColombo scienceplanning concept. Observation templates or classes will be tracked right through the planning-executionprocessing- archiving cycle to the final archived science products. By using an interface that synthesises all relevant available information, the science teams will have a better understanding of the operational environment; it will enhance their ability to plan efficiently minimising or removing manual planning. Interactive 3D visualisation of the planned, scheduled and executed observations, simulation of the viewing conditions and interactive modification of the observation parameters are also being considered.
Assessing a new hip index as a risk predictor for diabetes mellitus.
He, Sen; Zheng, Yi; Chen, Xiaoping
2017-09-30
Recently, a new anthropometric parameter (a new hip index [HI]) was developed, and the HI shows a U-shaped relationship to mortality in the USA population. It is well known that there is an inverse relationship between hip circumference (HC) and the risk of diabetes mellitus. Accordingly, the study sought to investigate whether HI could predict future diabetes mellitus, as compared with HC and the waist-to-hip ratio (WHR), in a general Chinese population. In 2007, we carried out a health examination of 687 participants (mean age 48.1 ± 6.2 years, male 58.1%). Development of diabetes mellitus by the 2007 examination was studied in relation to data from a baseline health examination carried out in 1992. During the follow up, 74 participants were diagnosed with diabetes mellitus. Across the quintiles of baseline HI, the incidence rates of diabetes mellitus were 12.4, 12.4, 9.9, 7.8 and 11.3% in quintile (Q)1, Q2, Q3, Q4 and Q5, respectively (P = 0.698). With the lowest quintile (Q1) as reference, univariate and multivariate Cox regression analyses showed that HI was not associated with diabetes mellitus. In contrast, HC and WHR could predict future diabetes mellitus. Furthermore, WHR had the best discriminatory power for diabetes mellitus (area under the receiver operating characteristic curve 0.691, 95% confidence interval 0.621-0.761), followed by HC (area under the receiver operating characteristic curve 0.623, 95% confidence interval 0.558-0.689) and HI (area under the receiver operating characteristic curve 0.464, 95% confidence interval 0.396-0.531). Compared with HC and WHR, HI was not an independent risk factor for diabetes mellitus in the Chinese population. More studies are required to delineate the limits of the utility of HI. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
Liu, Jing-Hua; Zou, Yu; Chang, Wei; Wu, Jun; Zou, Yu; Xie, Yu-Chen; Lu, Yong-Ping; Wei, Jia
2017-01-01
We assessed liver fibrosis using real-time shear-wave elastography (SWE) combined with liver biopsy (LB) for patients with hepatitis B e antigen (HBeAg)-negative chronic hepatitis B (CHB) and alanine transaminase < 2 times the upper limit of normal and hepatitis B virus DNA < 2000 IU/ml. A total of 107 patients met the inclusion criteria. Real- ime SWE and ultrasoundassisted liver biopsies were consecutively performed. Fibrosis was staged according to the METAVIR scoring system. Analyses of receiver operating characteristic curve were performed to calculate the optimal area under the receiver operating characteristic curve for F0-F1 versus F2-F4, F0-F2 versus F3-F4, and F0-F3 versus F4 for real-time SWE. The most concurrent liver fibrosis degrees were between F1 and F2 for these HBeAg-negative CHB patients. Liver stiffness increased in parallel with the degree of liver fibrosis using SWE measurements. The area under the receiver operating characteristic curves was 0.881 (95% confidence interval [CI]: 0.704-1.000) for SWE (p = 0.004); 0.912 (95% CI: 0.836-0.987) for SWE (p = 0.000); 0.981 (95% CI: 0.956-1.000) for SWE (p = 0.000); 0.974 (95% CI: 0.936-1.000) for SWE (p = 0.000) when comparing F0 versus F1-F4, F0-F1 versus F2-F4, F0-F2 versus F3-F4, and F0-F3 versus F4, respectively. SWE has the advantage of providing an image of liver stiffness in real-time. As an alternative to LB, the development of all these noninvasive methods for dynamic evaluation of liver fibrosis will decrease the need for LB, making clinical care safer and more convenient for patients with liver diseases.
NASA Technical Reports Server (NTRS)
Minnis, Patrick; Young, David F.; Heck, Patrick W.; Liou, Kuo-Nan; Takano, Yoshihide
1992-01-01
The First ISCCP (International Satellite Cloud Climatology Project) Regional Experiment (FIRE) Phase II Intensive Field Observations (IFO) were taken over southeastern Kansas between November 13 and December 7,1991, to determine cirrus cloud properties. The observations include in situ microphysical data; surface, aircraft, and satellite remote sensing; and measurements of divergence over meso- and smaller-scale areas using wind profilers. Satellite remote sensing of cloud characteristics is an essential aspect for understanding and predicting the role of clouds in climate variations. The objectives of the satellite cloud analysis during FIRE are to validate cloud property retrievals, develop advanced methods for extracting cloud information from satellite-measured radiances, and provide multiscale cloud data for cloud process studies and for verification of cloud generation models. This paper presents the initial results of cloud property analyses during FIRE-II using Geostationary Operational Environmental Satellite (GOES) data and NOAA Advanced Very High Resolution Radiometer (AVHRR) radiances.
Prediction of hydrocarbon surface seepage potential using infiltrometer data
NASA Astrophysics Data System (ADS)
Connors, J. J.; Jackson, J. L.; Engle, R. A.; Connors, J. L.
2017-12-01
Environmental regulations addressing above-ground storage tank (AST) spill control activities typically require owners/operators to demonstrate that local soil permeability values are low enough to adequately contain released liquids while emergency-response procedures are conducted. Frequently, geotechnical borings and soil samples/analyses, and/or monitoring well slug-test analyses, are used to provide hydraulic conductivity data for the required calculations. While these techniques are useful in assessing hydrological characteristics of the subsurface, they do not always assess the uppermost surface soil layer, where the bulk of the containment can occur. This layer may have been subject to long-term permeability-reduction by activities such as compaction by vehicular and foot traffic, micro-coatings by hydrophobic pollutants, etc. This presentation explores the usefulness of dual-ring infiltrometers, both in field and bench-scale tests, to rapidly acquire actual hydraulic conductivity values of surficial soil layers, which can be much lower than subsurface values determined using more traditional downhole geotechnical and hydrogeological approaches.
Dynamics of face and annular seals with two-phase flow
NASA Technical Reports Server (NTRS)
Hughes, William F.; Basu, Prithwish; Beatty, Paul A.; Beeler, Richard M.; Lau, Stephen
1988-01-01
A detailed study was made of face and annular seals under conditions where boiling, i.e., phase change of the leaking fluid, occurs within the seal. Many seals operate in this mode because of flashing due to pressure drop and/or heat input from frictional heating. Some of the distinctive behavior characteristics of two phase seals are discussed, particularly their axial stability. The main conclusions are that seals with two phase flow may be unstable if improperly balanced. Detailed theoretical analyses of low (laminar) and high (turbulent) leakage seals are presented along with computer codes, parametric studies, and in particular a simplified PC based code that allows for rapid performance prediction: calculations of stiffness coefficients, temperature and pressure distributions, and leakage rates for parallel and coned face seals. A simplified combined computer code for the performance prediction over the laminar and turbulent ranges of a two phase flow is described and documented. The analyses, results, and computer codes are summarized.
Campbell, Clare E; Maisto, Stephen A
2018-03-22
Research is needed to establish the psychometric properties of brief screens in university primary care settings. This study aimed to assess the construct validity of one such screen, the Alcohol Use Disorders Identification Test-Consumption (AUDIT-C), for detecting at-risk drinking among students who have utilized on-campus primary care. 389 students recently seen in university primary care completed a confidential online survey in December 2014. Bivariate correlations between the AUDIT-C and measures of alcohol consumption and negative drinking consequences provided concurrent evidence for construct validity. Receiver Operating Characteristic curve analyses determined optimal cut-off scores for at-risk drinking. The AUDIT-C significantly correlated with measures of alcohol consumption and negative drinking consequences (p < .001). Analyses support optimal AUDIT-C cut-off scores of 5 for females and 7 for males. The AUDIT-C is a valid screen for at-risk drinking among students who utilize university primary care.
The SPAIC-11 and SPAICP-11: Two brief child- and parent-rated measures of social anxiety.
Bunnell, Brian E; Beidel, Deborah C; Liu, Liwen; Joseph, Dana L; Higa-McMillan, Charmaine
2015-12-01
The Social Phobia and Anxiety Inventory for Children-11 (SPAIC-11) and Social Phobia and Anxiety Inventory for Children's Parents-11 (SPAICP-11) were developed as brief versions of the Social Phobia and Anxiety Inventory--Child and Parent Versions via item response theory (IRT) using child and parent reports of social anxiety. A sample of 496 children was analyzed using IRT analyses, revealing 11 items that exhibit measurement equivalence across parent and child reports. Descriptive and psychometric data are provided for the child, parent, and combined total scores. Discriminant validity was demonstrated using logistic regression and receiver operating characteristic curve analyses. The SPAIC-11 and SPAICP-11 are psychometrically sound measures that are able to measure social anxiety invariantly across children and their parents. These brief measures which include combined parent and child perception of the child's social anxiety may provide notable benefits to clinical research. Copyright © 2015 Elsevier Ltd. All rights reserved.
Space Shuttle Crawler Transporter Truck Shoe Qualification Tests and Analyses for Return-to-Flight
NASA Technical Reports Server (NTRS)
Margasahayam, Ravi N.; Meyer, Karl A.; Burton, Roy C.; Gosselin, Armand M.
2005-01-01
A vital element to Launch Complex 39 (LC39) and NASA's Kennedy Space Center (KSC) mobile launch transfer operation is a 3 million kilogram behemoth known as the Crawler Transporter (CT). Built in the 1960's, two CT's have accumulated over 1700+ miles each and have been used for the Apollo and the Space Shuttle programs. Recent observation of fatigue cracks on the CT shoes led to a comprehensive engineering, structural and metallurgical evaluation to assess the root cause that necessitated procurement of over 1000 new shoes. This paper documents the completed dynamic and compression tests on the old and new shoes respectively, so as to certify them for Space Shuttle's return-to-flight (RTF). Measured strain data from the rollout tests was used to develop stress/loading spectra and static equivalent load for qualification testing of the new shoes. Additionally, finite element analysis (FEA) was used to conduct sensitivity analyses of various contact parameters and structural characteristics for acceptance of new shoes.
Currency crisis indication by using ensembles of support vector machine classifiers
NASA Astrophysics Data System (ADS)
Ramli, Nor Azuana; Ismail, Mohd Tahir; Wooi, Hooy Chee
2014-07-01
There are many methods that had been experimented in the analysis of currency crisis. However, not all methods could provide accurate indications. This paper introduces an ensemble of classifiers by using Support Vector Machine that's never been applied in analyses involving currency crisis before with the aim of increasing the indication accuracy. The proposed ensemble classifiers' performances are measured using percentage of accuracy, root mean squared error (RMSE), area under the Receiver Operating Characteristics (ROC) curve and Type II error. The performances of an ensemble of Support Vector Machine classifiers are compared with the single Support Vector Machine classifier and both of classifiers are tested on the data set from 27 countries with 12 macroeconomic indicators for each country. From our analyses, the results show that the ensemble of Support Vector Machine classifiers outperforms single Support Vector Machine classifier on the problem involving indicating a currency crisis in terms of a range of standard measures for comparing the performance of classifiers.
14 CFR 133.41 - Flight characteristics requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Flight characteristics requirements. 133.41... EXTERNAL-LOAD OPERATIONS Airworthiness Requirements § 133.41 Flight characteristics requirements. (a) The applicant must demonstrate to the Administrator, by performing the operational flight checks prescribed in...
14 CFR 133.41 - Flight characteristics requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Flight characteristics requirements. 133.41... EXTERNAL-LOAD OPERATIONS Airworthiness Requirements § 133.41 Flight characteristics requirements. (a) The applicant must demonstrate to the Administrator, by performing the operational flight checks prescribed in...
14 CFR 133.41 - Flight characteristics requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Flight characteristics requirements. 133.41... EXTERNAL-LOAD OPERATIONS Airworthiness Requirements § 133.41 Flight characteristics requirements. (a) The applicant must demonstrate to the Administrator, by performing the operational flight checks prescribed in...
49 CFR 234.205 - Operating characteristics of warning system apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... apparatus. 234.205 Section 234.205 Transportation Other Regulations Relating to Transportation (Continued... characteristics of warning system apparatus. Operating characteristics of electromagnetic, electronic, or electrical apparatus of each highway-rail crossing warning system shall be maintained in accordance with the...
49 CFR 234.205 - Operating characteristics of warning system apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... apparatus. 234.205 Section 234.205 Transportation Other Regulations Relating to Transportation (Continued... characteristics of warning system apparatus. Operating characteristics of electromagnetic, electronic, or electrical apparatus of each highway-rail crossing warning system shall be maintained in accordance with the...
Recognition errors suggest fast familiarity and slow recollection in rhesus monkeys
Basile, Benjamin M.; Hampton, Robert R.
2013-01-01
One influential model of recognition posits two underlying memory processes: recollection, which is detailed but relatively slow, and familiarity, which is quick but lacks detail. Most of the evidence for this dual-process model in nonhumans has come from analyses of receiver operating characteristic (ROC) curves in rats, but whether ROC analyses can demonstrate dual processes has been repeatedly challenged. Here, we present independent converging evidence for the dual-process model from analyses of recognition errors made by rhesus monkeys. Recognition choices were made in three different ways depending on processing duration. Short-latency errors were disproportionately false alarms to familiar lures, suggesting control by familiarity. Medium-latency responses were less likely to be false alarms and were more accurate, suggesting onset of a recollective process that could correctly reject familiar lures. Long-latency responses were guesses. A response deadline increased false alarms, suggesting that limiting processing time weakened the contribution of recollection and strengthened the contribution of familiarity. Together, these findings suggest fast familiarity and slow recollection in monkeys, that monkeys use a “recollect to reject” strategy to countermand false familiarity, and that primate recognition performance is well-characterized by a dual-process model consisting of recollection and familiarity. PMID:23864646
The Martian surface as imaged, sampled, and analyzed by the Viking landers
NASA Technical Reports Server (NTRS)
Arvidson, Raymond E.; Gooding, James L.; Moore, Henry J.
1989-01-01
Data collected by two Viking landers are analyzed. Attention is given to the characteristics of the surface inferred from Lander imaging and meteorology data, physical and magnetic properties experiments, and both inorganic and organic analyses of Martian samples. Viking Lander 1 touched down on Chryse Planitia on July 20, 1976 and continued to operate for 2252 sols, until November 20, 1982. Lander 2 touched down about 6500 km away from Lander 1, on Utopia Planitia on September 3, 1976. The chemical compositions of sediments at the two landing sites are similar, suggesting an aeolian origin. The compositions suggest an iron-rich rock an are matched by various clays and salts.
A potassium Rankine multimegawatt nuclear electric propulsion concept
NASA Technical Reports Server (NTRS)
Baumeister, E.; Rovang, R.; Mills, J.; Sercel, J.; Frisbee, R.
1990-01-01
Multimegawatt nuclear electric propulsion (NEP) has been identified as a potentially attractive option for future space exploratory missions. A liquid-metal-cooled reactor, potassium Rankine power system that is being developed is suited to fulfill this application. The key features of the nuclear power system are described, and system characteristics are provided for various potential NEP power ranges and operational lifetimes. The results of recent mission studies are presented to illustrate some of the potential benefits to future space exploration to be gained from high-power NEP. Specifically, mission analyses have been performed to assess the mass and trip time performance of advanced NEP for both cargo and piloted missions to Mars.
NASA Astrophysics Data System (ADS)
Chen, Guangyan; Xia, Huaijian; Chen, Meiling; Wang, Dong; Jia, Sujin
2017-10-01
Energy saving and emission reduction policies affects the development of high power industry, thereby affecting electricity demand, so the study of the electricity industry boom helps to master the national economy. This paper analyses the influence of energy saving and emission reduction on power generation structure and pollutant emission in power industry. Through the construction of electricity market composite boom index to indicate electricity boom, using boom index to study volatility characteristics and trend of electricity market. Here we provide a method for the enterprise and the government, that it can infer the overall operation of the national economy situation from power data.
Radiological effluents released and public doses from nuclear power plants in Korea.
Son, Jung Kwon; Kim, Hee Geun; Kong, Tae Young; Ko, Jong Hyun; Lee, Goung Jin
2013-08-01
As of the end of 2010, there were 20 commercially operating nuclear reactors in Korea. Releases of radioactive effluents from nuclear power plants (NPPs) have increased continuously; the total radioactivity of effluent amount released in 2010 was 547.12 TBq. From 2001 to 2010, the annual average radioactivity of gaseous and liquid effluents per reactor was 11.61 TBq for pressurised water reactors and 118.12 TBq for pressurised heavy water reactors. Most of the radioactivity from gaseous and liquid effluents came from tritium. Based on the results of release trends and analyses, the characteristics of effluents have been investigated to improve the management of radioactive effluents from NPPs.
Vertical PM10 Characteristics and their Relation with Tropospheric Meteorology over Hong Kong
NASA Astrophysics Data System (ADS)
Hei Tong, Cheuk
2016-04-01
Small particulates or PM10, those with aerodynamic diameters less than 10 mm, can cause long term impairment to human health as they can penetrate deep and deposit on the wall of the respiratory system. Hong Kong receives significant concentration of cross-boundary particulates but at the same time produce domestic pollutants which altogether contribute to the total pollution problem. Recent research interest is paying more attention on the vertical characteristic of PM in the lower atmosphere as possible correlations exist along different altitude. Besides, there exists potential relationship between PM concentration aloft and the high-level weather condition. Yet, most studies focus only up to around 200 meters above sea level due to the proposed significance and the lack of technology. Undoubtedly, this is not enough in investigating the relation between vertical atmospheric profile and PM vertical characteristics. New technology development has allowed measuring PM concentration along the vertical atmospheric profile up to tropopause. This measurement relies on the Atmospheric Light Detection and Ranging (LiDAR) which operates using the radar principle to detect Rayleigh and Mie scattering from atmospheric gas and aerosols. The research involves (1) study of the seasonal vertical PM10 characteristics in five studying site of Hong Kong covering urban, suburban and rural area; (2) the relationship of the PM10 characteristics with meteorological parameters; (3) the vertical PM10 characteristics under the approach of tropical cyclones. A portable Micro Pulse Lidar (MPL) is adopted to collect PM data aloft while surface PM data is collected from ground stations. High-level meteorology data is received from Hong Kong Observatory. Statistical analyses are operated to investigate the correlation between weather conditions and PM concentration along the vertical profile. The research study is divided in phrases. The ultimate goal of the study is to develop models simulating high-level PM concentration under different meteorological conditions and predict the impacts under global and urban climate change. Keywords: PM10; High level meteorology; Seasonal variations; Tropical cyclone; Hong Kong; LiDAR
Li, Kun; Wang, Jianxing; Liu, Jibao; Wei, Yuansong; Chen, Meixue
2016-05-01
Municipal sewage from an oxidation ditch was treated for reuse by nanofiltration (NF) in this study. The NF performance was optimized, and its fouling characteristics after different operational durations (i.e., 48 and 169hr) were analyzed to investigate the applicability of nanofiltration for water reuse. The optimum performance was achieved when transmembrane pressure=12bar, pH=4 and flow rate=8L/min using a GE membrane. The permeate water quality could satisfy the requirements of water reclamation for different uses and local standards for water reuse in Beijing. Flux decline in the fouling experiments could be divided into a rapid flux decline and a quasi-steady state. The boundary flux theory was used to predict the evolution of permeate flux. The expected operational duration based on the 169-hr experiment was 392.6hr which is 175% longer than that of the 48-hr one. High molecular weight (MW) protein-like substances were suggested to be the dominant foulants after an extended period based on the MW distribution and the fluorescence characteristics. The analyses of infrared spectra and extracellular polymeric substances revealed that the roles of both humic- and polysaccharide-like substances were diminished, while that of protein-like substances were strengthened in the contribution of membrane fouling with time prolonged. Inorganic salts were found to have marginally influence on membrane fouling. Additionally, alkali washing was more efficient at removing organic foulants in the long term, and a combination of water flushing and alkali washing was appropriate for NF fouling control in municipal sewage treatment. Copyright © 2015. Published by Elsevier B.V.
Orbital operation study. Volume 2: Interfacing activities analysis. Part 1: Introduction and summary
NASA Technical Reports Server (NTRS)
Anderson, N. R.
1972-01-01
The summary of the interfacing activity analyses for the orbital operations study is presented. The significant analyses are grouped into categories as follows: (1) structural and mechanical activity, (2) data management, and (3) support operations. Specific subjects concerning payload deployment, communications, rendezvous, and stationkeeping are discussed.
Characteristics of advanced hydrogen maser frequency standards
NASA Technical Reports Server (NTRS)
Peters, H. E.
1973-01-01
Measurements with several operational atomic hydrogen maser standards have been made which illustrate the fundamental characteristics of the maser as well as the analysability of the corrections which are made to relate the oscillation frequency to the free, unperturbed, hydrogen standard transition frequency. Sources of the most important perturbations, and the magnitude of the associated errors, are discussed. A variable volume storage bulb hydrogen maser is also illustrated which can provide on the order of 2 parts in 10 to the 14th power or better accuracy in evaluating the wall shift. Since the other basic error sources combined contribute no more than approximately 1 part in 10 to the 14th power uncertainty, the variable volume storage bulb hydrogen maser will have net intrinsic accuracy capability of the order of 2 parts in 10 to the 14th power or better. This is an order of magnitude less error than anticipated with cesium standards and is comparable to the basic limit expected for a free atom hydrogen beam resonance standard.
The effect of balance holes to centrifugal pump performance
NASA Astrophysics Data System (ADS)
Babayigit, O.; Ozgoren, M.; Aksoy, M. H.; Kocaaslan, O.
2017-07-01
The aim of this study is to analyze of a centrifugal pump with and without balance holes by using ANSYS-Fluent software. The pump used in the study is a commercial centrifugal pump consisting of two stages that is a model of Sempa Pump Company. Firstly, models of impeller, diffuser, suction and discharge sections of the centrifugal pump were separately drawn using Ansys and Solidworks software. Later, grid structures were generated on the flow volume of the pump. Turbulent flow volume was numerically solved by realizable k-є turbulence model. The flow analyses were focused on the centrifugal pump performance and the flow characteristics under different operational conditions with/without balance holes. Distributions of flow characteristics such as velocity and pressure distributions in the flow volume were also determined, numerically. The results of Computational Fluid Dynamics (CFD) with/without balance holes for the pump head and hydraulic efficiency on the design flow rate of 80 m3/h were found to be 81.5/91.3 m and 51.9/65.3%, respectively.
Xia, Xue; Sun, Yanmei; Liang, Peng; Huang, Xia
2012-09-01
The long-term effect of set potential on oxygen reducing biocathodes was investigated in terms of electrochemical and biological characteristics. Three biocathodes were poised at 200, 60 and -100 mV vs. saturated calomel electrode (SCE) for 110 days, including the first 17 days for startup. Electrochemical analyses showed that 60 mV was the optimum potential during long-term operation. The performance of all the biocathodes kept increasing after startup, suggesting a period longer than startup time needed to make potential regulation more effective. The inherent characteristics without oxygen transfer limitation were studied. Different from short-term regulation, the amounts of biomass were similar while the specific electrochemical activity was significantly influenced by potential. Moreover, potential showed a strong selection for cathode bacteria. Clones 98% similar with an uncultured Bacteroidetes bacterium clone CG84 accounted for 75% to 80% of the sequences on the biocathodes that showed higher electrochemical activity (60 and -100 mV). Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Luo, Junhui; Mi, Decai; Ye, Qiongyao; Deng, Shengqiang; Zeng, Fuquan; Zeng, Yongjun
2018-01-01
Carbonaceous rock has the characteristics of easy disintegration, softening, swelling and environmental sensitivity, which belongs to soft surrounding rock, and the deformation during excavation and long-term stability of the surrounding rock of carbonaceous rock tunnel are common problems in the construction of carbonaceous rock tunnel. According to the above, the Monitor and measure the displacement, temperature and osmotic pressure of the surrounding carbonaceous rock of the tunnel of Guangxi Hebai highway. Then it based on the obtaining data to study the creep mechanism of surrounding rock using Singh-Mitchell model and predict the deformation of surrounding rock before the tunnel is operation. The results show that the Singh-Mitchell creep model can effectively analyse and predict the deformation development law of surrounding rock of tunnel without considering temperature and osmotic pressure, it can provide reference for the construction of carbonaceous rock tunnel and the measures to prevent and reinforce it..
Vibration and flutter characteristics of the SR7L large-scale propfan
NASA Technical Reports Server (NTRS)
August, Richard; Kaza, Krishna Rao V.
1988-01-01
An investigation of the vibration characteristics and aeroelastic stability of the SR7L Large-Scale Advanced Propfan was performed using a finite element blade model and an improved aeroelasticity code. Analyses were conducted for different blade pitch angles, blade support conditions, number of blades, rotational speeds, and freestream Mach numbers. A finite element model of the blade was used to determine the blade's vibration behavior and sensitivity to support stiffness. The calculated frequencies and mode shape obtained with this model agreed well with the published experimental data. A computer code recently developed at NASA Lewis Research Center and based on three-dimensional, unsteady, lifting surface aerodynamic theory was used for the aeroelastic analysis to examine the blade's stability at a cruise condition of Mach 0.8 at 1700 rpm. The results showed that the blade is stable for that operating point. However, a flutter condition was predicted if the cruise Mach number was increased to 0.9.
Wan, Thomas T.H.; Ma, Allen; Y.J.Lin, Blossom
2001-01-01
Abstract Purpose This study examines the integration effects on efficiency and financial viability of the top 100 integrated healthcare networks (IHNs) in the United States. Theory A contingency- strategic theory is used to identify the relationship of IHNs' performance to their structural and operational characteristics and integration strategies. Methods The lists of the top 100 IHNs ranked in two years, 1998 and 1999, by the SMG Marketing Group were merged to create a database for the study. Multiple indicators were used to examine the relationship between IHNs' characteristics and their performance in efficiency and financial viability. A path analytical model was developed and validated by the Mplus statistical program. Factors influencing the top 100 IHNs' images, represented by attaining ranking among the top 100 in two consecutive years, were analysed. Results and conclusion No positive associations were found between integration and network performance in efficiency or profits. Longitudinal data are needed to investigate the effect of integration on healthcare networks' financial performance. PMID:16896405
Lots, Froukje A E; Behrens, Paul; Vijver, Martina G; Horton, Alice A; Bosker, Thijs
2017-10-15
Here we present the large-scale distribution of microplastic contamination in beach sediment across Europe. Sediment samples were collected from 23 locations across 13 countries by citizen scientists, and analysed using a standard operating procedure. We found significant variability in the concentrations of microplastics, ranging from 72±24 to 1512±187 microplastics per kg of dry sediment, with high variability within sampling locations. Three hotspots of microplastic accumulation (>700 microplastics per kg of dry sediment) were found. There was limited variability in the physico-chemical characteristics of the plastics across sampling locations. The majority of the microplastics were fibrous, <1mm in size, and blue/black in colour. In addition, using Raman spectrometry we identified particles as polyester, polyethylene, and polypropylene. Our research is the first large spatial-scale analysis of microplastics on European beaches giving insights into the nature and extent of the microplastic challenge. Copyright © 2017 Elsevier Ltd. All rights reserved.
Physically-based in silico light sheet microscopy for visualizing fluorescent brain models
2015-01-01
Background We present a physically-based computational model of the light sheet fluorescence microscope (LSFM). Based on Monte Carlo ray tracing and geometric optics, our method simulates the operational aspects and image formation process of the LSFM. This simulated, in silico LSFM creates synthetic images of digital fluorescent specimens that can resemble those generated by a real LSFM, as opposed to established visualization methods producing visually-plausible images. We also propose an accurate fluorescence rendering model which takes into account the intrinsic characteristics of fluorescent dyes to simulate the light interaction with fluorescent biological specimen. Results We demonstrate first results of our visualization pipeline to a simplified brain tissue model reconstructed from the somatosensory cortex of a young rat. The modeling aspects of the LSFM units are qualitatively analysed, and the results of the fluorescence model were quantitatively validated against the fluorescence brightness equation and characteristic emission spectra of different fluorescent dyes. AMS subject classification Modelling and simulation PMID:26329404
Development of a plasma sprayed ceramic gas path seal for high pressure turbine applications
NASA Technical Reports Server (NTRS)
Shiembob, L. T.
1977-01-01
The plasma sprayed graded layered yittria stabilized zirconia (ZrO2)/metal(CoCrAlY) seal system for gas turbine blade tip applications up to 1589 K (2400 F) seal temperatures was studied. Abradability, erosion, and thermal fatigue characteristics of the graded layered system were evaluated by rig tests. Satisfactory abradability and erosion resistance was demonstrated. Encouraging thermal fatigue tolerance was shown. Initial properties for the plasma sprayed materials in the graded, layered seal system was obtained, and thermal stress analyses were performed. Sprayed residual stresses were determined. Thermal stability of the sprayed layer materials was evaluated at estimated maximum operating temperatures in each layer. Anisotropic behavior in the layer thickness direction was demonstrated by all layers. Residual stresses and thermal stability effects were not included in the analyses. Analytical results correlated reasonably well with results of the thermal fatigue tests. Analytical application of the seal system to a typical gas turbine engine application predicted performance similar to rig specimen thermal fatigue performance. A model for predicting crack propagation in the sprayed ZrO2/CoCrAlY seal system was proposed, and recommendations for improving thermal fatigue resistance were made. Seal system layer thicknesses were analytically optimized to minimize thermal stresses in the abradability specimen during thermal fatigue testing. Rig tests on the optimized seal configuration demonstrated some improvement in thermal fatigue characteristics.
49 CFR 236.8 - Operating characteristics of electromagnetic, electronic, or electrical apparatus.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 4 2014-10-01 2014-10-01 false Operating characteristics of electromagnetic, electronic, or electrical apparatus. 236.8 Section 236.8 Transportation Other Regulations Relating to... characteristics of electromagnetic, electronic, or electrical apparatus. Signal apparatus, the functioning of...
49 CFR 236.8 - Operating characteristics of electromagnetic, electronic, or electrical apparatus.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 4 2012-10-01 2012-10-01 false Operating characteristics of electromagnetic, electronic, or electrical apparatus. 236.8 Section 236.8 Transportation Other Regulations Relating to... characteristics of electromagnetic, electronic, or electrical apparatus. Signal apparatus, the functioning of...
49 CFR 236.8 - Operating characteristics of electromagnetic, electronic, or electrical apparatus.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 4 2013-10-01 2013-10-01 false Operating characteristics of electromagnetic, electronic, or electrical apparatus. 236.8 Section 236.8 Transportation Other Regulations Relating to... characteristics of electromagnetic, electronic, or electrical apparatus. Signal apparatus, the functioning of...
49 CFR 236.8 - Operating characteristics of electromagnetic, electronic, or electrical apparatus.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 4 2011-10-01 2011-10-01 false Operating characteristics of electromagnetic, electronic, or electrical apparatus. 236.8 Section 236.8 Transportation Other Regulations Relating to... characteristics of electromagnetic, electronic, or electrical apparatus. Signal apparatus, the functioning of...
49 CFR 236.8 - Operating characteristics of electromagnetic, electronic, or electrical apparatus.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 4 2010-10-01 2010-10-01 false Operating characteristics of electromagnetic, electronic, or electrical apparatus. 236.8 Section 236.8 Transportation Other Regulations Relating to... characteristics of electromagnetic, electronic, or electrical apparatus. Signal apparatus, the functioning of...
Schulze, Matthias B.; Weikert, Cornelia; Pischon, Tobias; Bergmann, Manuela M.; Al-Hasani, Hadi; Schleicher, Erwin; Fritsche, Andreas; Häring, Hans-Ulrich; Boeing, Heiner; Joost, Hans-Georg
2009-01-01
OBJECTIVE We investigated whether metabolic biomarkers and single nucleotide polymorphisms (SNPs) improve diabetes prediction beyond age, anthropometry, and lifestyle risk factors. RESEARCH DESIGN AND METHODS A case-cohort study within a prospective study was designed. We randomly selected a subcohort (n = 2,500) from 26,444 participants, of whom 1,962 were diabetes free at baseline. Of the 801 incident type 2 diabetes cases identified in the cohort during 7 years of follow-up, 579 remained for analyses after exclusions. Prediction models were compared by receiver operatoring characteristic (ROC) curve and integrated discrimination improvement. RESULTS Case-control discrimination by the lifestyle characteristics (ROC-AUC: 0.8465) improved with plasma glucose (ROC-AUC: 0.8672, P < 0.001) and A1C (ROC-AUC: 0.8859, P < 0.001). ROC-AUC further improved with HDL cholesterol, triglycerides, γ-glutamyltransferase, and alanine aminotransferase (0.9000, P = 0.002). Twenty SNPs did not improve discrimination beyond these characteristics (P = 0.69). CONCLUSIONS Metabolic markers, but not genotyping for 20 diabetogenic SNPs, improve discrimination of incident type 2 diabetes beyond lifestyle risk factors. PMID:19720844
Oser, Carrie B.; Roman, Paul M.
2014-01-01
Objective Prominent on the nation's research agenda on substance-use disorders treatment is the dissemination of effective pharmacotherapies. Thus, the purpose of this article is to use a “diffusion of innovations” theoretical framework to examine the organizational-level predictors of the adoption of a pharmacotherapy, naltrexone (Revia), in private substance use-disorders treatment centers (N = 165). Method Data for these analyses were derived from the National Treatment Center Study, which contains four waves of data collected between 1994 and 2003. An event history model examined the impact of culture, leadership characteristics, internal structure, and external characteristics on the likelihood of adopting naltrexone between 1994 and 2003. Results The results suggest that organizations embracing a 12-step model and those employing more experienced administrators were significantly less likely to adopt naltrexone. Moreover, treatment centers that used prescription drugs, possessed an employee handbook, were accredited, and operated on a for-profit basis were significantly more likely to adopt naltrexone over time. Conclusions Structural characteristics do affect the innovation adoption behaviors of private substance-use disorders treatment centers. Organizational-level “research to practice” implications to further the adoption of innovative evidence-based treatments are discussed. PMID:17960303
2013-12-01
Tropical cyclone research is an intense ongoing science that has acquired even greater importance in this era of global climate change . Increased study of...RECONNAISSANCE WITH THE GLOBAL HAWK: OPERATIONAL THRESHOLDS AND CHARACTERISTICS OF CONVECTIVE SYSTEMS OVER THE TROPICAL WESTERN NORTH PACIFIC by...TROPICAL CYCLONE RECONNAISSANCE WITH THE GLOBAL HAWK: OPERATIONAL THRESHOLDS AND CHARACTERISTICS OF CONVECTIVE SYSTEMS OVER THE TROPICAL WESTERN
Huston, Jared M; Kao, Lillian S; Chang, Phillip K; Sanders, James M; Buckman, Sara; Adams, Charles A; Cocanour, Christine S; Parli, Sarah E; Grabowski, Julia; Diaz, Jose; Tessier, Jeffrey M; Duane, Therese M
2017-07-01
Acute appendicitis is the most common abdominal surgical emergency in the United States, with a lifetime risk of 7%-8%. The treatment paradigm for complicated appendicitis has evolved over the past decade, and many cases now are managed by broad-spectrum antibiotics. We determined the role of non-operative and operative management in adult patients with uncomplicated appendicitis. Several meta-analyses have attempted to clarify the debate. Arguably the most influential is the Appendicitis Acuta (APPAC) Trial. According to the non-inferiority analysis and a pre-specified non-inferiority margin of -24%, the APPAC did not demonstrate non-inferiority of antibiotics vs. appendectomy. Significantly, however, the operations were nearly always open, whereas the majority of appendectomies in the United States are done laparoscopically; and laparoscopic and open appendectomies are not equivalent operations. Treatment with antibiotics is efficacious more than 70% of the time. However, a switch to an antimicrobial-only approach may result in a greater probability of antimicrobial-associated collateral damage, both to the host patient and to antibiotic susceptibility patterns. A surgery-only approach would result in a reduction in antibiotic exposure, a consideration in these days of focus on antimicrobial stewardship. Future studies should focus on isolating the characteristics of appendicitis most susceptible to antibiotics, using laparoscopic operations as controls and identifying long-term side effects such as antibiotic resistance or Clostridium difficile colitis.
Clinical value of the neutrophil/lymphocyte ratio in diagnosing adult strangulated inguinal hernia.
Zhou, Huanhao; Ruan, Xiaojiao; Shao, Xia; Huang, Xiaming; Fang, Guan; Zheng, Xiaofeng
2016-12-01
Diagnosis of incarcerated inguinal hernia (IIH) is not difficult, but currently, there are no diagnostic criteria that can be used to differentiate it from strangulated inguinal hernia (SIH). This research aimed to evaluate the clinical value of the neutrophil/lymphocyte ratio (NLR) in diagnosing SIH. We retrospectively analyzed 263 patients with IIH who had undergone emergency operation. The patients were divided into two groups according to IIH severity: group A, patients with pure IIH validated during operation as having no bowel ischemia; group B, patients with SIH validated during operation as having obvious bowel ischemia, including bowel necrosis. We statistically evaluated the relation between several clinical features and SIH. The accuracy of different indices was then evaluated and compared using receiver operating characteristic (ROC) curve analyses, and the corresponding cutoff values were calculated. Univariate analysis showed eight clinical features that were significantly different between the two groups. They were then subjected to multivariate analysis, which showed that the NLR, type of hernia, and incarcerated organ were significantly related to SIH. ROC curve analysis showed that the NLR had the largest area under the ROC curve. Among the different clinical features, the NLR appears to be the best index in diagnosing SIH. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Summers, W.A.
1998-08-01
The H2Fuel Bus is the world`s first hybrid hydrogen electric transit bus. It was developed through a public/private partnership involving several leading technology and industrial organizations in the Southeast, with primary funding and program management provided by the Department of Energy. The primary goals of the project are to gain valuable information on the technical readiness and economic viability of hydrogen buses and to enhance the public awareness and acceptance of emerging hydrogen technologies. The bus has been operated by the transit agency in Augusta, Georgia since April, 1997. It employs a hybrid IC engine/battery/electric drive system, with onboard hydrogenmore » fuel storage based on the use of metal hydrides. Initial operating results have demonstrated an overall energy efficiency (miles per Btu) of twice that of a similar diesel-fueled bus and an operating range twice that of an all-battery powered electric bus. Tailpipe emissions are negligible, with NOx less than 0.2 ppm. Permitting, liability and insurance issues were addressed on the basis of extensive risk assessment and safety analyses, with the inherent safety characteristic of metal hydride storage playing a major role in minimizing these concerns. Future plans for the bus include continued transit operation and use as a national testbed, with potential modifications to demonstrate other hydrogen technologies, including fuel cells.« less
Multichannel, Active Low-Pass Filters
NASA Technical Reports Server (NTRS)
Lev, James J.
1989-01-01
Multichannel integrated circuits cascaded to obtain matched characteristics. Gain and phase characteristics of channels of multichannel, multistage, active, low-pass filter matched by making filter of cascaded multichannel integrated-circuit operational amplifiers. Concept takes advantage of inherent equality of electrical characteristics of nominally-identical circuit elements made on same integrated-circuit chip. Characteristics of channels vary identically with changes in temperature. If additional matched channels needed, chips containing more than two operational amplifiers apiece (e.g., commercial quad operational amplifliers) used. Concept applicable to variety of equipment requiring matched gain and phase in multiple channels - radar, test instruments, communication circuits, and equipment for electronic countermeasures.
Does training of fellows affect peri-operative outcomes of robot-assisted partial nephrectomy?
Khene, Zine-Eddine; Peyronnet, Benoit; Bosquet, Elise; Pradère, Benjamin; Robert, Corentin; Fardoun, Tarek; Kammerer-Jacquet, Solène-Florence; Verhoest, Grégory; Rioux-Leclercq, Nathalie; Mathieu, Romain; Bensalah, Karim
2017-10-01
To evaluate the impact of fellows' involvement on the peri-operative outcomes of robot-assisted partial nephrectomy (RAPN). We analysed 216 patients who underwent RAPN for a small renal tumour. We stratified our cohort into two groups according to the involvement of a fellow surgeon during the procedure: expert surgeon operating alone (expert group) and fellow operating under the supervision of the expert surgeon (fellow group). Peri-operative data were compared between the two groups. Linear and logistic regression analyses were performed to assess the impact of fellows' involvement on peri-operative and postoperative outcomes. Trifecta and margins ischaemia complications (MIC) score achievement rates were used to assess the quality of surgery in both the expert and fellow groups. Trifecta was defined as a combination of warm ischaemia time <25 min, negative surgical margins and no peri-operative complications. MIC score was defined as negative surgical margins, ischaemia time <20 min, and absence of complications grade ≥3. Fellows were involved in a total of 89 procedures (41%). Patients' characteristics were similar in the two groups. Operating time and warm ischaemia time (WIT) were longer in the fellow group (180 vs 120 min, P < 0.001, and 18 vs 14 min, P = 0.002, respectively). Length of hospital stay (LOS) was longer in the fellow group (5 vs 4.3 days; P = 0.05) and patients in this group had higher estimated blood loss (EBL; 400 vs 300 mL; P = 0.01), but this had no impact on transfusion rate (14% vs 11%; P = 0.43). Positive surgical margin rates were similar in the fellow and expert groups (2.2% vs 3.1%; P = 0.70). Major complications were more frequent in the fellow group (12.3% vs 6.3%), but the difference was not significant (P = 0.10). In multivariable analysis, fellow involvement was predictive of longer WIT (β = 0.22; P = 0.003) and operating time (β = 0.49; P < 0.001), but was not associated with EBL (β = 0.12, P = 0.09) or LOS (β = 0.12, P = 0.11). Finally, fellow involvement was associated with a lower rate of trifecta and MIC score accomplishment (odds ratio [OR] 0.53, P = 0.05 and OR 0.46, P = 0.01, respectively). Training fellows to perform RAPN is associated with longer operating time and WIT but does not appear to compromise other peri-operative outcomes. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
Small Aircraft Transportation System Simulation Analysis of the HVO and ERO Concepts
NASA Technical Reports Server (NTRS)
Millsaps, Gary D.; Yackovetsky, Robert E. (Technical Monitor)
2003-01-01
It is acknowledged that the aviation and aerospace industries are primary forces influencing the industrial development and economic well being of the United States and many countries around the world. For decades the US national air transportation system has been the model of success - safely and efficiently moving people, cargo, goods and services and generating countless benefits throughout the global community; however, the finite nature of the system and many of its components is becoming apparent. Without measurable increases in the capacity of the national air transportation system, delays and service delivery failures will eventually become intolerable. Although the recent economic slowdown has lowered immediate travel demands, that trend is reversing and cargo movement remains high. Research data indicates a conservative 2.5-3.0% annual increase in aircraft operations nationwide through 2017. Such growth will place additional strains upon a system already experiencing capacity constraints. The stakeholders of the system will continue to endure ever-increasing delays and abide lesser levels of service to many lower population density areas of the country unless more efficient uses of existing and new transportation resources are implemented. NASA s Small Aircraft Transportation System program (SATS) is one of several technologies under development that are aimed at using such resources more effectively. As part of this development effort, this report is the first in a series outlining the findings and recommendations resulting from a comprehensive program of multi-level analyses and system engineering efforts undertaken by NASA Langley Research Center s Systems Analysis Branch (SAB). These efforts are guided by a commitment to provide systems-level analysis support for the SATS program. Subsequent efforts will build upon this early work to produce additional analyses and benefits studies needed to provide the technical and economic basis for national investment and policy decisions related to further development and potential deployment of a small aircraft transportation system. This report primarily serves two purposes. First, it presents results attained from an initial evaluation and analysis of the Higher Volume Operations (HVO) and EnRoute Operations (ERO) concepts - both designated operational capabilities within the SATS Program s Concept of Operations (CONOPS) document. It further outlines areas of the concepts that would benefit from follow-on analyses and system engineering efforts. It is intended that these processes will aid continued maturation of the concepts and promote additional studies of their effects and influences in combination with other designated CONOPS currently under development. In essence, it establishes a baseline of data upon which subsequent analyses and studies can be built and identifies performance characteristics the concept must exhibit in order to provide, at minimum, levels of safety and usage equal to or better than the current system.
NASA Technical Reports Server (NTRS)
Selcuk, M. K.; Fujita, T.
1984-01-01
A simple graphical method was developed to undertake technical design trade-off studies for individual parabolic dish models comprising a two-axis tracking parabolic dish with a cavity receiver and power conversion assembly at the focal point. The results of these technical studies are then used in performing the techno-economic analyses required for determining appropriate subsystem sizing. Selected graphs that characterize the performance of subsystems within the module were arranged in the form of a nomogram that would enable an investigator to carry out several design trade-off studies. Key performance parameters encompassed in the nomogram include receiver losses, intercept factor, engine rating, and engine efficiency. Design and operation parameters such as concentrator size, receiver type (open or windowed aperture), receiver aperture size, operating temperature of the receiver and engine, engine partial load characteristics, concentrator slope error, and the type of reflector surface, are also included in the graphical solution. Cost considerations are not included.
Matias-Guiu, Pau; Rodríguez-Bencomo, Juan José; Orriols, Ignacio; Pérez-Correa, José Ricardo; López, Francisco
2016-12-15
The organoleptic quality of wine distillates depends on raw materials and the distillation process. Previous work has shown that rectification columns in batch distillation with fixed reflux rate are useful to obtain distillates or distillate fractions with enhanced organoleptic characteristics. This study explores variable reflux rate operating strategies to increase the levels of terpenic compounds in specific distillate fractions to emphasize its floral aroma. Based on chemical and sensory analyses, two distillate heart sub-fractions obtained with the best operating strategy found, were compared with a distillate obtained in a traditional alembic. Results have shown that a drastic reduction of the reflux rate at an early stage of the heart cut produced a distillate heart sub-fraction with a higher concentration of terpenic compounds and lower levels of negative aroma compounds. Therefore, this sub-fraction presented a much more noticeable floral aroma than the distillate obtained with a traditional alembic. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Shollenberger, C. A.; Smyth, D. N.
1978-01-01
A nonlinear, nonplanar three dimensional jet flap analysis, applicable to the ground effect problem, is presented. Lifting surface methodology is developed for a wing with arbitrary planform operating in an inviscid and incompressible fluid. The classical, infintely thin jet flap model is employed to simulate power induced effects. An iterative solution procedure is applied within the analysis to successively approximate the jet shape until a converged solution is obtained which closely satisfies jet and wing boundary conditions. Solution characteristics of the method are discussed and example results are presented for unpowered, basic powered and complex powered configurations. Comparisons between predictions of the present method and experimental measurements indicate that the improvement of the jet with the ground plane is important in the analyses of powered lift systems operating in ground proximity. Further development of the method is suggested in the areas of improved solution convergence, more realistic modeling of jet impingement and calculation efficiency enhancements.
LPG sensing characteristics of electrospray deposited SnO2 nanoparticles
NASA Astrophysics Data System (ADS)
Gürbüz, Mevlüt; Günkaya, Göktuğ; Doğan, Aydın
2014-11-01
In this study, SnO2 films were fabricated on conductive substrate such as aluminum and platinum coated alumina using electro-spray deposition (ESD) method for gas sensor applications. Solution flow rate, coating time, substrate-nozzle distance and solid/alcohol ratio were studied to optimize SnO2 film structure. The morphology of the deposited films was characterized by stereo and scanning electron microscopy (SEM). The gas sensing properties of tin oxide films were investigated using liquid petroleum gas (LPG) for various lower explosive limit (LEL). The results obtained from microscopic analyses show that optimum SnO2 films were evaluated at flow rate of 0.05 ml/min, at distance of 6 cm, for 10 min deposition time, for 20 gSnO2/Lethanol ratio and at 7 kV DC electric field. By the results obtained from the gas sensing behavior, the sensitivity of the films was increased with operating temperature. The films showed better sensitivity for 20 LEL LPG concentration at 450 °C operating temperature.
Bouza, Marcos; Orejas, Jaime; López-Vidal, Silvia; Pisonero, Jorge; Bordel, Nerea; Pereiro, Rosario; Sanz-Medel, Alfredo
2016-05-23
Atmospheric pressure glow discharges have been widely used in the last decade as ion sources in ambient mass spectrometry analyses. Here, an in-house flowing atmospheric pressure afterglow (FAPA) has been developed as an alternative ion source for differential mobility analysis (DMA). The discharge source parameters (inter-electrode distance, current and helium flow rate) determining the atmospheric plasma characteristics have been optimized in terms of DMA spectral simplicity with the highest achievable sensitivity while keeping an adequate plasma stability and so the FAPA working conditions finally selected were: 35 mA, 1 L min(-1) of He and an inter-electrode distance of 8 mm. Room temperature in the DMA proved to be adequate for the coupling and chemical analysis with the FAPA source. Positive and negative ions for different volatile organic compounds were tested and analysed by FAPA-DMA using a Faraday cup as a detector and proper operation in both modes was possible (without changes in FAPA operational parameters). The FAPA ionization source showed simpler ion mobility spectra with narrower peaks and a better, or similar, sensitivity than conventional UV-photoionization for DMA analysis in positive mode. Particularly, the negative mode proved to be a promising field of further research for the FAPA ion source coupled to ion mobility, clearly competitive with other more conventional plasmas such as corona discharge.
Perineal body length and perineal lacerations during delivery in primigravid patients
Lane, T. Lance; Chung, Christopher P.; Yandell, Paul M.; Kuehl, Thomas J.
2017-01-01
This study assessed the relation between perineal body length and the risk of perineal laceration extending into the anal sphincter during vaginal delivery in primigravid patients at an institution with a low utilization of episiotomy. This was a prospective study of primigravid patients in active labor. Primigravid women with singleton pregnancies who were in the first stage of labor at 37 weeks gestation or greater were recruited, and the admitting physician measured the length of the perineal body. The degree of perineal laceration and other delivery characteristics were recorded. Data were analyzed using univariate analyses, receiver-operator curve analyses, and multiple logistic regression for factors associated with increased severity of vaginal lacerations. The perineal body length, duration of second stage of labor, type of delivery, and patient age were associated (P < 0.1) with third- and fourth-degree (severe) perineal lacerations in primigravid women using receiver-operator curve analysis. Using logistic regression, only the duration of second stage of labor and length of the perineal body were significant (P < 0.04) predictors of third- and fourth-degree lacerations, with odds ratios of 32 (1.3 to 807 as 95% CI) and 24 (1.3 to 456), respectively. Both a perineal body length of ≤3.5 cm and a duration of second stage of labor >99 minutes were associated with an increased risk of third- and fourth-degree lacerations in primigravid patients. PMID:28405063
Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marginean, Ioan; Tang, Keqi; Smith, Richard D.
2014-01-01
Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, themore » ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.« less
Rajamohan, Sakthivel; Kasimani, Ramesh
2018-04-01
This paper aims to analyse the characteristics and properties of the fractions obtained from slow pyrolysis of non-edible seed cake of Calophyllum inophyllum (CI). The gas, bio-oil and biochar obtained from the pyrolysis carried out at 500 °C in a fixed bed batch type reactor at a heating rate of 30 °C/min were characterized by various analytical techniques. Owing to the high volatile content of CI biomass (72.61%), it was selected as the raw material in this present investigation. GC-MS and FT-IR analysis of bio-oil showed the presence of higher amount of oxygenated compounds, phenol derivatives, esters, acid and furans. The physicochemical properties of the bio-oil were tested as per ASTM norms which imply that bio-oil is a highly viscous liquid with lower heating value as compared to that of diesel fuel. The chemical composition of evolved gas was analysed by using GC testing which revealed the presence of combustible components. The FT-IR characterization of biochar showed the presence of aliphatic and aromatic hydrocarbons whereas the elevated amount of carbon in biochar indicates its potential to be used as solid fuel. The performance and emission characteristics of CI engine were assessed with different CI bio-oil blends and compared with baseline diesel fuel. The results showed that addition of bio-oil leads to decreased brake thermal efficiency and increased brake specific energy consumption. Meanwhile, increase in blend ratio reduces harmful pollutants such as oxides of nitrogen and smoke in the exhaust. From the engine testing, it is suggested to employ 20% of CI bio-oil blends in CI engine to obtain better operation.
Screening for cognitive dysfunction in Huntington's disease with the clock drawing test.
Terwindt, Paul W; Hubers, Anna A M; Giltay, Erik J; van der Mast, Rose C; van Duijn, Erik
2016-09-01
The aim of the study is to investigate the performance of the clock drawing test as a screening tool for cognitive impairment in Huntington's disease (HD) mutation carriers. The performance of the clock drawing test was assessed in 65 mutation carriers using the Shulman and the Freund scoring systems. The mini-mental state examination, the Symbol Digit Modalities Test, the Verbal Fluency Test, and the Stroop tests were used as comparisons for the evaluation of cognitive functioning. Correlations of the clock drawing test with various cognitive tests (convergent validity), neuropsychiatric characteristics (divergent validity) and clinical characteristics were analysed using the Spearman's rank correlation coefficient. Receiver-operator characteristic analyses were performed for the clock drawing test against both the mini-mental state examination and against a composite variable for executive cognitive functioning to assess optimal cut-off scores. Inter-rater reliability was high for both the Shulman and Freund scoring systems (ICC = 0.95 and ICC = 0.90 respectively). The clock drawing tests showed moderate to high correlations with the composite variable for executive cognitive functioning (mean ρ = 0.75) and weaker correlations with the mini-mental state examination (mean ρ = 0.62). Mean sensitivity of the clock drawing tests was 0.82 and mean specificity was 0.79, whereas the mean positive predictive value was 0.66 and the mean negative predictive value was 0.87. The clock drawing test is a suitable screening instrument for cognitive dysfunction in HD, because it was shown to be accurate, particularly so with respect to executive cognitive functioning, and is easy and quick to use. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Satre, Derek D; Altschuler, Andrea; Parthasarathy, Sujaya; Silverberg, Michael J; Volberding, Paul; Campbell, Cynthia I
2016-12-15
This study examined implementation of the Affordable Care Act (ACA) in relation to HIV-positive patient enrollment in an integrated health care system; as well as changes in new enrollee characteristics, benefit structure, and health care utilization after key ACA provisions went into effect in 2014. This mixed-methods study was set in Kaiser Permanente Northern California (KPNC). Qualitative interviews with 29 KPNC leaders explored planning for ACA implementation. Quantitative analyses compared newly enrolled HIV-positive patients in KPNC between January and December 2012 ("pre-ACA," N = 661) with newly enrolled HIV-positive patients between January and December 2014 ("post-ACA," N = 880) on demographics; medical, psychiatric, and substance use disorder diagnoses; HIV clinical indicators; and type of health care utilization. Interviews found that ACA preparation focused on enrollment growth, staffing, competition among health plans, concern about cost sharing, and HIV pre-exposure prophylaxis (PrEP) services. Quantitative analyses found that post-ACA HIV-positive patient enrollment grew. New enrollees in 2014 were more likely than 2012 enrollees to be enrolled in high-deductible plans (P < 0.01) or through Medicaid (P < 0.01), and marginally more likely to have better HIV viral control (P < 0.10). They also were more likely to be diagnosed with asthma (P < 0.01) or substance use disorders (P < 0.05) and to have used primary care health services in the 6 months postenrollment (P < 0.05) than the pre-ACA cohort. As anticipated by KPNC interviewees, ACA implementation was followed by HIV-positive patient enrollment growth and changing benefit structures and patient characteristics. Although HIV viral control improved, comorbid diagnosis findings reinforced the importance of coordinated health care.
Limotai, Chusak; McLachlan, Richard S; Hayman-Abello, Susan; Hayman-Abello, Brent; Brown, Suzan; Bihari, Frank; Mirsattari, Seyed M
2018-06-19
This study was aimed to longitudinally assess memory function and whole-brain memory circuit reorganization in patients with temporal lobe epilepsy (TLE) by comparing activation potentials before versus after anterior temporal lobe (ATL) resection. Nineteen patients with medically-intractable TLE (10 left TLE, 9 right TLE) and 15 healthy controls were enrolled. Group analyses were conducted pre- and post-ATL of a novelty complex scene-encoding paradigm comparing areas of blood oxygen-level-dependent (BOLD) signal activations on functional magnetic resonance imaging (fMRI). None of the pre-operative patient characteristics we studied predicted the extent of pre- to post-operative memory loss. On fMRI, extra-temporal activations were detected pre-operatively in both LTLE and RTLE, particularly in the frontal lobe. Greater activations also were noted in the contralateral hippocampus and parahippocampus in both groups. Performing within-subject comparisons, post-op relative to pre-op, pronounced ipsilateral activations were identified in the left parahippocampal gyrus in LTLE, versus the right middle temporal gyrus in RTLE patients. Memory function was impaired pre-operatively but declined after ATL resection in both RTLE and LTLE patients. Post-operative fMRI results indicate possible functional adaptations to ATL loss, primarily occurring within the left parahippocampal gyrus versus right middle temporal gyrus in LTLE versus RTLE patients, respectively. Copyright © 2018 Elsevier Ltd. All rights reserved.
Operation and biasing for single device equivalent to CMOS
Welch, James D.
2001-01-01
Disclosed are semiconductor devices including at least one junction which is rectifying whether the semiconductor is caused to be N or P-type, by the presence of field induced carriers. In particular, inverting and non-inverting gate voltage channel induced semiconductor single devices with operating characteristics similar to conventional multiple device CMOS systems, which can be operated as modulators, are disclosed as are a non-latching SCR and an approach to blocking parasitic currents. Operation of the gate voltage channel induced semiconductor single devices with operating characteristics similar to multiple device CMOS systems under typical bias schemes is described, and simple demonstrative five mask fabrication procedures for the inverting and non-inverting gate voltage channel induced semiconductor single devices with operating characteristics similar to multiple device CMOS systems are also presented.
McGrath, Trevor A; McInnes, Matthew D F; Korevaar, Daniël A; Bossuyt, Patrick M M
2016-10-01
Purpose To determine whether authors of systematic reviews of diagnostic accuracy studies published in imaging journals used recommended methods for meta-analysis, and to evaluate the effect of traditional methods on summary estimates of sensitivity and specificity. Materials and Methods Medline was searched for published systematic reviews that included meta-analysis of test accuracy data limited to imaging journals published from January 2005 to May 2015. Two reviewers independently extracted study data and classified methods for meta-analysis as traditional (univariate fixed- or random-effects pooling or summary receiver operating characteristic curve) or recommended (bivariate model or hierarchic summary receiver operating characteristic curve). Use of methods was analyzed for variation with time, geographical location, subspecialty, and journal. Results from reviews in which study authors used traditional univariate pooling methods were recalculated with a bivariate model. Results Three hundred reviews met the inclusion criteria, and in 118 (39%) of those, authors used recommended meta-analysis methods. No change in the method used was observed with time (r = 0.54, P = .09); however, there was geographic (χ(2) = 15.7, P = .001), subspecialty (χ(2) = 46.7, P < .001), and journal (χ(2) = 27.6, P < .001) heterogeneity. Fifty-one univariate random-effects meta-analyses were reanalyzed with the bivariate model; the average change in the summary estimate was -1.4% (P < .001) for sensitivity and -2.5% (P < .001) for specificity. The average change in width of the confidence interval was 7.7% (P < .001) for sensitivity and 9.9% (P ≤ .001) for specificity. Conclusion Recommended methods for meta-analysis of diagnostic accuracy in imaging journals are used in a minority of reviews; this has not changed significantly with time. Traditional (univariate) methods allow overestimation of diagnostic accuracy and provide narrower confidence intervals than do recommended (bivariate) methods. (©) RSNA, 2016 Online supplemental material is available for this article.
Validation of self-reported figural drawing scales against anthropometric measurements in adults.
Dratva, Julia; Bertelsen, Randi; Janson, Christer; Johannessen, Ane; Benediktsdóttir, Bryndis; Bråbäck, Lennart; Dharmage, Shyamali C; Forsberg, Bertil; Gislason, Thorarinn; Jarvis, Debbie; Jogi, Rain; Lindberg, Eva; Norback, Dan; Omenaas, Ernst; Skorge, Trude D; Sigsgaard, Torben; Toren, Kjell; Waatevik, Marie; Wieslander, Gundula; Schlünssen, Vivi; Svanes, Cecilie; Real, Francisco Gomez
2016-08-01
The aim of the present study was to validate figural drawing scales depicting extremely lean to extremely obese subjects to obtain proxies for BMI and waist circumference in postal surveys. Reported figural scales and anthropometric data from a large population-based postal survey were validated with measured anthropometric data from the same individuals by means of receiver-operating characteristic curves and a BMI prediction model. Adult participants in a Scandinavian cohort study first recruited in 1990 and followed up twice since. Individuals aged 38-66 years with complete data for BMI (n 1580) and waist circumference (n 1017). Median BMI and waist circumference increased exponentially with increasing figural scales. Receiver-operating characteristic curve analyses showed a high predictive ability to identify individuals with BMI > 25·0 kg/m2 in both sexes. The optimal figural scales for identifying overweight or obese individuals with a correct detection rate were 4 and 5 in women, and 5 and 6 in men, respectively. The prediction model explained 74 % of the variance among women and 62 % among men. Predicted BMI differed only marginally from objectively measured BMI. Figural drawing scales explained a large part of the anthropometric variance in this population and showed a high predictive ability for identifying overweight/obese subjects. These figural scales can be used with confidence as proxies of BMI and waist circumference in settings where objective measures are not feasible.
Kanegaye, John T; Jones, Jefferson M; Burns, Jane C; Jain, Sonia; Sun, Xiaoying; Jimenez-Fernandez, Susan; Berry, Erika; Pancheri, Joan M; Jaggi, Preeti; Ramilo, Octavio; Tremoulet, Adriana H
2016-01-01
Important therapeutic decisions are made based on the presence or absence of fever in patients with Kawasaki disease (KD), yet no standard method or threshold exists for temperature measurement during the diagnosis and treatment of these patients. We sought to compare surface and internal (rectal or oral) routes of temperature measurement for the detection of fever as a marker of treatment resistance. From a randomized, placebo-controlled trial of infliximab as an adjunct to primary intravenous immunoglobulin treatment for acute KD, we collected concurrent (within 5 minutes) axillary and internal temperature measurements and performed receiver-operating characteristic and Bland-Altman analyses. We also determined the ability of surface temperatures to detect treatment resistance defined by internal temperature measurements. Among 452 oral-axillary and 439 rectal-axillary pairs from 159 patients, mean axillary temperatures were 0.25 and 0.43 °C lower than oral and rectal temperatures and had high receiver-operating characteristic areas under curves. However, axillary temperatures ≥ 38.0 °C had limited sensitivity to detect fever defined by internal temperatures. Axillary thresholds of 37.5 and 37.2 °C provided maximal sensitivity and specificity to detect oral and rectal temperatures ≥ 38.0 °C, respectively. Axillary temperatures are an insensitive metric for fevers defining treatment resistance. Clinical trials should adopt temperature measurement by the oral or rectal routes for adjudication of treatment resistance in KD.
Marković, Snežana; Kerč, Janez; Horvat, Matej
2017-03-01
We are presenting a new approach of identifying sources of variability within a manufacturing process by NIR measurements of samples of intermediate material after each consecutive unit operation (interprocess NIR sampling technique). In addition, we summarize the development of a multivariate statistical process control (MSPC) model for the production of enteric-coated pellet product of the proton-pump inhibitor class. By developing provisional NIR calibration models, the identification of critical process points yields comparable results to the established MSPC modeling procedure. Both approaches are shown to lead to the same conclusion, identifying parameters of extrusion/spheronization and characteristics of lactose that have the greatest influence on the end-product's enteric coating performance. The proposed approach enables quicker and easier identification of variability sources during manufacturing process, especially in cases when historical process data is not straightforwardly available. In the presented case the changes of lactose characteristics are influencing the performance of the extrusion/spheronization process step. The pellet cores produced by using one (considered as less suitable) lactose source were on average larger and more fragile, leading to consequent breakage of the cores during subsequent fluid bed operations. These results were confirmed by additional experimental analyses illuminating the underlying mechanism of fracture of oblong pellets during the pellet coating process leading to compromised film coating.
Quilty, Lena C; Avila Murati, Daniela; Bagby, R Michael
2014-03-01
Many gamblers would prefer to reduce gambling on their own rather than to adopt an abstinence approach within the context of a gambling treatment program. Yet responsible gambling guidelines lack quantifiable markers to guide gamblers in wagering safely. To address these issues, the current investigation implemented receiver operating characteristic (ROC) analysis to identify behavioral indicators of harmful and problem gambling. Gambling involvement was assessed in 503 participants (275 psychiatric outpatients and 228 community gamblers) with the Canadian Problem Gambling Index. Overall gambling frequency, duration, and expenditure were able to distinguish harmful and problematic gambling at a moderate level. Indicators of harmful gambling were generated for engagement in specific gambling activities: frequency of tickets and casino; duration of bingo, casino, and investments; and expenditures on bingo, casino, sports betting, games of skill, and investments. Indicators of problem gambling were similarly produced for frequency of tickets and casino, and expenditures on bingo, casino, games of skill, and investments. Logistic regression analyses revealed that overall gambling frequency uniquely predicted the presence of harmful and problem gambling. Furthermore, frequency indicators for tickets and casino uniquely predicted the presence of both harmful and problem gambling. Together, these findings contribute to the development of an empirically based method enabling the minimization of harmful or problem gambling through self-control rather than abstinence.
Kairisto, V; Poola, A
1995-01-01
GraphROC for Windows is a program for clinical test evaluation. It was designed for the handling of large datasets obtained from clinical laboratory databases. In the user interface, graphical and numerical presentations are combined. For simplicity, numerical data is not shown unless requested. Relevant numbers can be "picked up" from the graph by simple mouse operations. Reference distributions can be displayed by using automatically optimized bin widths. Any percentile of the distribution with corresponding confidence limits can be chosen for display. In sensitivity-specificity analysis, both illness- and health-related distributions are shown in the same graph. The following data for any cutoff limit can be shown in a separate click window: clinical sensitivity and specificity with corresponding confidence limits, positive and negative likelihood ratios, positive and negative predictive values and efficiency. Predictive values and clinical efficiency of the cutoff limit can be updated for any prior probability of disease. Receiver Operating Characteristics (ROC) curves can be generated and combined into the same graph for comparison of several different tests. The area under the curve with corresponding confidence interval is calculated for each ROC curve. Numerical results of analyses and graphs can be printed or exported to other Microsoft Windows programs. GraphROC for Windows also employs a new method, developed by us, for the indirect estimation of health-related limits and change limits from mixed distributions of clinical laboratory data.
NASA Astrophysics Data System (ADS)
Hidema, R.
2014-08-01
In order to study the effects of extensional viscosities on turbulent drag reduction, experimental studies using two-dimensional turbulence have been made. Anisotropic structures and variations of energy transfer induced by polymers are considered. Polyethyleneoxide and hydroxypropyl cellulose having different flexibility, which is due to different characteristics of extensional viscosity, are added to 2D turbulence. Variations of the turbulence were visualized by interference patterns of 2D flow, and were analysed by an image processing. The effects of polymers on turbulence in the streamwise and normal directions were also analysed by 2D Fourier transform. In addition, characteristic scales in 2D turbulence were analysed by wavelet transform.
ERIC Educational Resources Information Center
Sanchez, Daniel J.; Reber, Paul J.
2012-01-01
The memory system that supports implicit perceptual-motor sequence learning relies on brain regions that operate separately from the explicit, medial temporal lobe memory system. The implicit learning system therefore likely has distinct operating characteristics and information processing constraints. To attempt to identify the limits of the…
Space shuttle orbit maneuvering engine
NASA Technical Reports Server (NTRS)
Pauckert, R. P.
1975-01-01
Data on the performance, stability, and thermal characteristics of an OME operating with an alternate injector configuration and with alternate propellants was obtained. The design, manufacturing, and operating characteristics of an electroformed, regeneratively cooled thrust chamber were also derived. Subscale and full scale tests provide data relating to off-design and transient operation.
Yank, Veronica; Rennie, Drummond; Bero, Lisa A
2007-12-08
To determine whether financial ties to one drug company are associated with favourable results or conclusions in meta-analyses on antihypertensive drugs. Retrospective cohort study. Meta-analyses published up to December 2004 that were not duplicates and evaluated the effects of antihypertensive drugs compared with any comparator on clinical end points in adults. Financial ties were categorised as one drug company compared with all others. The main outcomes were the results and conclusions of meta-analyses, with both outcomes separately categorised as being favourable or not favourable towards the study drug. We also collected data on characteristics of meta-analyses that the literature suggested might be associated with favourable results or conclusions. 124 meta-analyses were included in the study, 49 (40%) of which had financial ties to one drug company. On univariate logistic regression analyses, meta-analyses of better methodological quality were more likely to have favourable results (odds ratio 1.16, 95% confidence interval 1.07 to 1.27). Although financial ties to one drug company were not associated with favourable results, such ties constituted the only characteristic significantly associated with favourable conclusions (4.09, 1.30 to 12.83). When controlling for other characteristics of meta-analyses in multiple logistic regression analyses, meta-analyses that had financial ties to one drug company remained more likely to report favourable conclusions (5.11, 1.54 to 16.92). Meta-analyses on antihypertensive drugs and with financial ties to one drug company are not associated with favourable results but are associated with favourable conclusions.
Computer programing for geosciences: Teach your students how to make tools
NASA Astrophysics Data System (ADS)
Grapenthin, Ronni
2011-12-01
When I announced my intention to pursue a Ph.D. in geophysics, some people gave me confused looks, because I was working on a master's degree in computer science at the time. My friends, like many incoming geoscience graduate students, have trouble linking these two fields. From my perspective, it is pretty straightforward: Much of geoscience evolves around novel analyses of large data sets that require custom tools—computer programs—to minimize the drudgery of manual data handling; other disciplines share this characteristic. While most faculty adapted to the need for tool development quite naturally, as they grew up around computer terminal interfaces, incoming graduate students lack intuitive understanding of programing concepts such as generalization and automation. I believe the major cause is the intuitive graphical user interfaces of modern operating systems and applications, which isolate the user from all technical details. Generally, current curricula do not recognize this gap between user and machine. For students to operate effectively, they require specialized courses teaching them the skills they need to make tools that operate on particular data sets and solve their specific problems. Courses in computer science departments are aimed at a different audience and are of limited help.
NASA Technical Reports Server (NTRS)
Unal, Resit; Morris, W. Douglas; White, Nancy H.; Lepsch, Roger A.; Brown, Richard W.
2000-01-01
This paper describes the development of parametric models for estimating operational reliability and maintainability (R&M) characteristics for reusable vehicle concepts, based on vehicle size and technology support level. A R&M analysis tool (RMAT) and response surface methods are utilized to build parametric approximation models for rapidly estimating operational R&M characteristics such as mission completion reliability. These models that approximate RMAT, can then be utilized for fast analysis of operational requirements, for lifecycle cost estimating and for multidisciplinary sign optimization.
Characteristics of a 30-cm thruster operated with small hole accelerator grid ion optics
NASA Technical Reports Server (NTRS)
Vahrenkamp, R. P.
1976-01-01
Small hole accelerator grid ion optical systems have been tested as a possible means of improving 30-cm ion thruster performance. The effects of small hole grids on the critical aspects of thruster operation including discharge chamber performance, doubly-charged ion concentration, effluent beam characteristics, and plasma properties have been evaluated. In general, small hole accelerator grids are beneficial in improving thruster performance while maintaining low double ion ratios. However, extremely small accelerator aperture diameters tend to degrade beam divergence characteristics. A quantitative discussion of these advantages and disadvantages of small hole accelerator grids, as well as resulting variations in thruster operation characteristics, is presented.
NASA Technical Reports Server (NTRS)
1989-01-01
Requirements are presented for shuttle system definition; performance and design characteristics; shuttle vehicle end item performance and design characteristics; ground operations complex performance and design characteristics; operability and system design and construction standards; and quality control.
User handbook for block IV silicon solar cell modules
NASA Technical Reports Server (NTRS)
Smokler, M. I.
1982-01-01
The essential electrical and mechanical characteristics of block 4 photovoltaic solar cell modules are described. Such module characteristics as power output, nominal operating voltage, current-voltage characteristics, nominal operating cell temperature, and dimensions are tabulated. The limits of the environmental and other stress tests to which the modules are subjected are briefly described.
Study of Civil Markets for Heavy-Lift Airships
NASA Technical Reports Server (NTRS)
Mettam, P. J.; Hansen, D.; Chabot, C.; Byrne, R.
1978-01-01
The civil markets for heavy lift airships (HLAs) were defined by first identifying areas of most likely application. The operational suitability of HLAs for the applications identified were then assessed. The operating economics of HLAs were established and the market size for HLA services estimated by comparing HLA operating and economic characteristics with those of competing modes. The sensitivities of the market size to HLA characteristics were evaluated and the number and sizes of the vehicles required to service the more promising markets were defined. Important characteristics for future HLAs are discussed that were derived from the study of each application, including operational requirements, features enhancing profitability, military compatibility, improved design requirements, approach to entry into service, and institutional implications for design and operation.
Logistic Regression in the Identification of Hazards in Construction
NASA Astrophysics Data System (ADS)
Drozd, Wojciech
2017-10-01
The construction site and its elements create circumstances that are conducive to the formation of risks to safety during the execution of works. Analysis indicates the critical importance of these factors in the set of characteristics that describe the causes of accidents in the construction industry. This article attempts to analyse the characteristics related to the construction site, in order to indicate their importance in defining the circumstances of accidents at work. The study includes sites inspected in 2014 - 2016 by the employees of the District Labour Inspectorate in Krakow (Poland). The analysed set of detailed (disaggregated) data includes both quantitative and qualitative characteristics. The substantive task focused on classification modelling in the identification of hazards in construction and identifying those of the analysed characteristics that are important in an accident. In terms of methodology, resource data analysis using statistical classifiers, in the form of logistic regression, was the method used.
The cost structure of routine infant immunization services: a systematic analysis of six countries
Geng, Fangli; Suharlim, Christian; Brenzel, Logan; Resch, Stephen C; Menzies, Nicolas A
2017-01-01
Abstract Little information exists on the cost structure of routine infant immunization services in low- and middle-income settings. Using a unique dataset of routine infant immunization costs from six countries, we estimated how costs were distributed across budget categories and programmatic activities, and investigated how the cost structure of immunization sites varied by country and site characteristics. The EPIC study collected data on routine infant immunization costs from 319 sites in Benin, Ghana, Honduras, Moldova, Uganda, Zambia, using a standardized approach. For each country, we estimated the economic costs of infant immunization by administrative level, budget category, and programmatic activity from a programme perspective. We used regression models to describe how costs within each category were related to site operating characteristics and efficiency level. Site-level costs (incl. vaccines) represented 77–93% of national routine infant immunization costs. Labour and vaccine costs comprised 14–69% and 13–69% of site-level cost, respectively. The majority of site-level resources were devoted to service provision (facility-based or outreach), comprising 48–78% of site-level costs across the six countries. Based on the regression analyses, sites with the highest service volume had a greater proportion of costs devoted to vaccines, with vaccine costs per dose relatively unaffected by service volume but non-vaccine costs substantially lower with higher service volume. Across all countries, more efficient sites (compared with sites with similar characteristics) had a lower cost share devoted to labour. The cost structure of immunization services varied substantially between countries and across sites within each country, and was related to site characteristics. The substantial variation observed in this sample suggests differences in operating model for otherwise similar sites, and further understanding of these differences could reveal approaches to improve efficiency and performance of immunization sites. PMID:28575193
Vijayaraghavan, K; Raja, Franklin D
2014-10-15
Many studies worldwide have investigated the potential benefits achievable by transforming brown roofs of buildings to green roofs. However, little literature examined the runoff quality/sorption ability of green roofs. As the green roof substrate is the main component to alter the quality of runoff, this investigation raises the possibility of using a mixture of low-cost inorganic materials to develop a green roof substrate. The tested materials include exfoliated vermiculite, expanded perlite, crushed brick and sand along with organic component (coco-peat). Detailed physical and chemical analyses revealed that each of these materials possesses different characteristics and hence a mix of these materials was desirable to develop an optimal green roof substrate. Using factorial design, 18 different substrate mixes were prepared and detailed examination indicated that mix-12 exhibited desirable characteristics of green roof substrate with low bulk density (431 kg/m(3)), high water holding capacity (39.4%), air filled porosity (19.5%), and hydraulic conductivity (4570 mm/h). The substrate mix also provided maximum support to Portulaca grandiflora (380% total biomass increment) over one month of growth. To explore the leaching characteristics and sorption capacity of developed green roof substrate, a down-flow packed column arrangement was employed. High conductivity and total dissolved solids along with light metal ions (Na, K, Ca and Mg) were observed in the leachates during initial stages of column operation; however the concentration of ions ceased during the final stages of operation (600 min). Experiments with metal-spiked deionized water revealed that green roof substrate possess high sorption capacity towards various heavy metal ions (Al, Fe, Cr, Cu, Ni, Pb, Zn and Cd). Thus the developed growth substrate possesses desirable characteristics for green roofs along with high sorption capacity. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cong, X C; Yang, G S; Qu, J H; Dai, M X
2016-11-01
A study to investigate the dynamical characteristics of particle matter emissions in a working open yard is conducted in Caofeidian Port of Hebei Province, China. The average diurnal concentrations of the total suspended particulate (TSP) matter and respirable particulate matter (PM 10 and PM 5 ) are monitored during the field measurement campaign. Sampling is performed at a regular interval at 8 monitoring stations in the yard with normal industrial activities. The average TSP, PM 10 and PM 5 concentrations range from 285 to 568, 198 to 423 and 189 to 330 μg.m-3 in the yard, respectively. The linear regression correlation coefficient of TSP/PM 10 and TSP/PM 5 is 0.95±0.01 and 0.88±0.02, respectively.By using the Spearman correlation method, the wind speed and relative humidity are both weakly correlated with the PM 10 and PM 5 concentrations according to the measurements. In addition, industrial operation activities, such as vehicular traffic in the yard and the loading time of stackers, are significantly positively correlated with the PM concentration. Using the multivariate regression method, the main parameters influencing the TSP concentration variations are integratedly analysed. The traffic volume is found to be a significant predictor of TSP concentration variation, with the smallest P value (P<0.05).To understand the dynamical characteristics of particle emissions in the yard, the emissions from the truck transports, that is, from unpaved haul roads and from the loading process, are established. Then, the dynamical emission factor (EF D ) based on the industrial activities in the yard is proposed. The dynamical emissions average 5.25x10 5 kg.year -1 and EF D is evaluated to be 0.29 kg.(ton.day) -1 during the measurement period. These outcomes have meaningful implications not only for understanding the dynamical characteristics of particle emissions in the working stockyard but also for implementing effective control measures at appropriate sites in the harbour area.
The cost structure of routine infant immunization services: a systematic analysis of six countries.
Geng, Fangli; Suharlim, Christian; Brenzel, Logan; Resch, Stephen C; Menzies, Nicolas A
2017-10-01
Little information exists on the cost structure of routine infant immunization services in low- and middle-income settings. Using a unique dataset of routine infant immunization costs from six countries, we estimated how costs were distributed across budget categories and programmatic activities, and investigated how the cost structure of immunization sites varied by country and site characteristics. The EPIC study collected data on routine infant immunization costs from 319 sites in Benin, Ghana, Honduras, Moldova, Uganda, Zambia, using a standardized approach. For each country, we estimated the economic costs of infant immunization by administrative level, budget category, and programmatic activity from a programme perspective. We used regression models to describe how costs within each category were related to site operating characteristics and efficiency level. Site-level costs (incl. vaccines) represented 77-93% of national routine infant immunization costs. Labour and vaccine costs comprised 14-69% and 13-69% of site-level cost, respectively. The majority of site-level resources were devoted to service provision (facility-based or outreach), comprising 48-78% of site-level costs across the six countries. Based on the regression analyses, sites with the highest service volume had a greater proportion of costs devoted to vaccines, with vaccine costs per dose relatively unaffected by service volume but non-vaccine costs substantially lower with higher service volume. Across all countries, more efficient sites (compared with sites with similar characteristics) had a lower cost share devoted to labour. The cost structure of immunization services varied substantially between countries and across sites within each country, and was related to site characteristics. The substantial variation observed in this sample suggests differences in operating model for otherwise similar sites, and further understanding of these differences could reveal approaches to improve efficiency and performance of immunization sites. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
Takahashi, H; Ishii, K; Hosokawa, C; Hyodo, T; Kashiwagi, N; Matsuki, M; Ashikaga, R; Murakami, T
2014-05-01
Alzheimer disease is the most common neurodegenerative disorder with dementia, and a practical and economic biomarker for diagnosis of Alzheimer disease is needed. Three-dimensional arterial spin-labeling, with its high signal-to-noise ratio, enables measurement of cerebral blood flow precisely without any extrinsic tracers. We evaluated the performance of 3D arterial spin-labeling compared with SPECT, and demonstrated the 3D arterial spin-labeled imaging characteristics in the diagnosis of Alzheimer disease. This study included 68 patients with clinically suspected Alzheimer disease who underwent both 3D arterial spin-labeling and SPECT imaging. Two readers independently assessed both images. Kendall W coefficients of concordance (K) were computed, and receiver operating characteristic analyses were performed for each reader. The differences between the images in regional perfusion distribution were evaluated by means of statistical parametric mapping, and the incidence of hypoperfusion of the cerebral watershed area, referred to as "borderzone sign" in the 3D arterial spin-labeled images, was determined. Readers showed K = 0.82/0.73 for SPECT/3D arterial spin-labeled imaging, and the respective areas under the receiver operating characteristic curve were 0.82/0.69 for reader 1 and 0.80/0.69 for reader 2. Statistical parametric mapping showed that the perisylvian and medial parieto-occipital perfusion in the arterial spin-labeled images was significantly higher than that in the SPECT images. Borderzone sign was observed on 3D arterial spin-labeling in 70% of patients misdiagnosed with Alzheimer disease. The diagnostic performance of 3D arterial spin-labeling and SPECT for Alzheimer disease was almost equivalent. Three-dimensional arterial spin-labeled imaging was more influenced by hemodynamic factors than was SPECT imaging. © 2014 by American Journal of Neuroradiology.
Novel white matter tract integrity metrics sensitive to Alzheimer disease progression.
Fieremans, E; Benitez, A; Jensen, J H; Falangola, M F; Tabesh, A; Deardorff, R L; Spampinato, M V S; Babb, J S; Novikov, D S; Ferris, S H; Helpern, J A
2013-01-01
Along with cortical abnormalities, white matter microstructural changes such as axonal loss and myelin breakdown are implicated in the pathogenesis of Alzheimer disease. Recently, a white matter model was introduced that relates non-Gaussian diffusional kurtosis imaging metrics to characteristics of white matter tract integrity, including the axonal water fraction, the intra-axonal diffusivity, and the extra-axonal axial and radial diffusivities. This study reports these white matter tract integrity metrics in subjects with amnestic mild cognitive impairment (n = 12), Alzheimer disease (n = 14), and age-matched healthy controls (n = 15) in an effort to investigate their sensitivity, diagnostic accuracy, and associations with white matter changes through the course of Alzheimer disease. With tract-based spatial statistics and region-of-interest analyses, increased diffusivity in the extra-axonal space (extra-axonal axial and radial diffusivities) in several white matter tracts sensitively and accurately discriminated healthy controls from those with amnestic mild cognitive impairment (area under the receiver operating characteristic curve = 0.82-0.95), while widespread decreased axonal water fraction discriminated amnestic mild cognitive impairment from Alzheimer disease (area under the receiver operating characteristic curve = 0.84). Additionally, these white matter tract integrity metrics in the body of the corpus callosum were strongly correlated with processing speed in amnestic mild cognitive impairment (r = |0.80-0.82|, P < .001). These findings have implications for the course and spatial progression of white matter degeneration in Alzheimer disease, suggest the mechanisms by which these changes occur, and demonstrate the viability of these white matter tract integrity metrics as potential neuroimaging biomarkers of the earliest stages of Alzheimer disease and disease progression.
Maeda, Ichiro; Kubota, Manabu; Ohta, Jiro; Shinno, Kimika; Tajima, Shinya; Ariizumi, Yasushi; Doi, Masatomo; Oana, Yoshiyasu; Kanemaki, Yoshihide; Tsugawa, Koichiro; Ueno, Takahiko; Takagi, Masayuki
2017-12-01
The aim of this study was to develop a computer-aided diagnosis (CADx) system for identifying breast pathology. Two sets of 100 consecutive core needle biopsy (CNB) specimens were collected for test and validation studies. All 200 CNB specimens were stained with antibodies targeting oestrogen receptor (ER), synaptophysin and CK14/p63. All stained slides were scanned in a whole-slide imaging system and photographed. The photographs were analysed using software to identify the proportions of tumour cells that were positive and negative for each marker. In the test study, the cut-off values for synaptophysin (negative and positive) and CK14/p63 (negative and positive) were decided using receiver operating characteristic (ROC) analysis. For ER analysis, samples were divided into groups with <10% positive or >10% positive cells and decided using receiver operating characteristic (ROC) analysis. Finally, these two groups categorised as ER-low, ER-intermediate (non-low and non-high) and ER-high groups. In the validation study, the second set of immunohistochemical slides were analysed using these cut-off values. The cut-off values for synaptophysin, <10% ER positive, >10% ER positive and CK14/p63 were 0.14%, 2.17%, 77.93% and 18.66%, respectively. The positive predictive value for malignancy (PPV) was 100% for synaptophysin-positive/ER-high/(CK14/p63)-any or synaptophysin-positive/ER-low/(CK14/p63)-any. The PPV was 25% for synaptophysin-positive/ER-intermediate/(CK14/p63)-positive. For synaptophysin-negative/(CK14/p63)-negative, the PPVs for ER-low, ER-intermediate and ER-high were 100%, 80.0% and 95.8%, respectively. The PPV was 4.5% for synaptophysin-negative/ER-intermediate/(CK14/p63)-positive. The CADx system was able to analyse sufficient data for all types of epithelial proliferative lesions of the breast including invasive breast cancer. This system may be useful for pathological diagnosis of breast CNB in routine investigations. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Enlarging the operation range of a centrifugal compressor by cutting vanes based on CFD
NASA Astrophysics Data System (ADS)
Mo, J. T.; Gu, C. H.; Pan, X. H.; Y Zheng, S.
2013-12-01
Many centrifugal compressors are liable to insufficient operation range. The purpose of this paper is to enlarge the operation range of a centrifugal compressor used in turbocharger by cutting vanes. Some numerical works have been done based on CFD. The comparison of the calculated and measured results shows good agreement. The overall performance characteristics of the centrifugal compressor with different cutted vanes are observed and analyzed. The performance characteristic curves show that cutting vanes can increase the operation range by more than 50% with the loss of the highest efficiency limited in 1%. The flow fields are also shown in this paper and related explanations about the change of the performance characteristics curves are given. Shock wave is also detected in the simulation, and some related characteristics are summed up.
Fatigue analyses of the prototype Francis runners based on site measurements and simulations
NASA Astrophysics Data System (ADS)
Huang, X.; Chamberland-Lauzon, J.; Oram, C.; Klopfer, A.; Ruchonnet, N.
2014-03-01
With the increasing development of solar power and wind power which give an unstable output to the electrical grid, hydropower is required to give a rapid and flexible compensation, and the hydraulic turbines have to operate at off-design conditions frequently. Prototype Francis runners suffer from strong vibrations induced by high pressure pulsations at part load, low part load, speed-no-load and during start-stops and load rejections. Fatigue and damage may be caused by the alternating stress on the runner blades. Therefore, it becomes increasingly important to carry out fatigue analysis and life time assessment of the prototype Francis runners, especially at off-design conditions. This paper presents the fatigue analyses of the prototype Francis runners based on the strain gauge site measurements and numerical simulations. In the case of low part load, speed-no-load and transient events, since the Francis runners are subjected to complex hydraulic loading, which shows a stochastic characteristic, the rainflow counting method is used to obtain the number of cycles for various dynamic amplitude ranges. From middle load to full load, pressure pulsations caused by Rotor-stator- Interaction become the dominant hydraulic excitation of the runners. Forced response analysis is performed to calculate the maximum dynamic stress. The agreement between numerical and experimental stresses is evaluated using linear regression method. Taking into account the effect of the static stress on the S-N curve, the Miner's rule, a linear cumulative fatigue damage theory, is employed to calculate the damage factors of the prototype Francis runners at various operating conditions. The relative damage factors of the runners at different operating points are compared and discussed in detail.
Ji, Xin; Bu, Zhao-De; Li, Zi-Yu; Wu, Ai-Wen; Zhang, Lian-Hai; Zhang, Ji; Wu, Xiao-Jiang; Zong, Xiang-Long; Li, Shuang-Xi; Shan, Fei; Jia, Zi-Yu; Ji, Jia-Fu
2017-08-22
The relationship between the number of harvested lymph nodes (HLNs) and prognosis of gastric cancer patients without an involvement of lymph nodes has not been well-evaluated. The objective of this study is to further explore this issue. We collected data from 399 gastric cancer patients between November 2006 and October 2011. All of them were without metastatic lymph nodes. Survival analyses showed that statistically significant differences existed in the survival outcomes between the two groups allocated by the total number of HLNs ranging from 16 to 22. Therefore, we adopted 22 as the cut-off value of the total number of HLNs for grouping (group A: HLNs <22; group B: HLNs≥22). The intraoperative and postoperative characteristics, including operative blood loss (P=0.096), operation time (P=0.430), postoperative hospital stay (P=0.142), complications (P=0.552), rate of reoperation (P=0.966) and postoperative mortality (P=1.000), were comparable between the two groups. T-stage-stratified Kaplan-Meier analyses revealed that the 5-year survival rate of patients at the T4 stage was better in group B than in group A (76.9% vs. 58.5%; P=0.004). An analysis of multiple factors elucidated that the total number of HLNs, T stage, operation time and age were independently correlated factors of prognosis. Regarding gastric cancer patients without the involvement of lymph nodes, an HLN number ≥22 would be helpful in prolonging their overall survival, especially for those at T4 stage. The total number of HLNs was an independent prognostic factor for this population of patients.
Li, Pu; Qin, Chao; Cao, Qiang; Li, Jie; Lv, Qiang; Meng, Xiaoxin; Ju, Xiaobing; Tang, Lijun; Shao, Pengfei
2016-10-01
To evaluate the feasibility and efficiency of laparoscopic partial nephrectomy (LPN) with segmental renal artery clamping, and to analyse the factors affecting postoperative renal function. We conducted a retrospective analysis of 466 consecutive patients undergoing LPN using main renal artery clamping (group A, n = 152) or segmental artery clamping (group B, n = 314) between September 2007 and July 2015 in our department. Blood loss, operating time, warm ischaemia time (WIT) and renal function were compared between groups. Univariable and multivariable linear regression analyses were applied to assess the correlations of selected variables with postoperative glomerular filtration rate (GFR) reduction. Volumetric data and estimated GFR of a subset of 60 patients in group B were compared with GFR to evaluate the correlation between these functional variables and preserved renal function after LPN. The novel technique slightly increased operating time, WIT and intra-operative blood loss (P < 0.001), while it provided better postoperative renal function (P < 0.001) compared with the conventional technique. The blocking method and tumour characteristics were independent factors affecting GFR reduction, while WIT was not an independent factor. Correlation analysis showed that estimated GFR presented better correlation with GFR compared with kidney volume (R(2) = 0.794 cf. R(2) = 0.199) in predicting renal function after LPN. LPN with segmental artery clamping minimizes warm ischaemia injury and provides better early postoperative renal function compared with clamping the main renal artery. Kidney volume has a significantly inferior role compared with eGFR in predicting preserved renal function. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.
Derosier, C; Leclercq, S; Rabardel, P; Langa, P
2008-12-01
Accidents on the level (AOL) rank second amongst the most numerous and serious occupational accidents with days lost in France and are a major health and safety problem in every sector of activity. The case study described in this paper was conducted at a metallurgical company with 300 employees. The aims of this work were dual: 1) to extend the general knowledge required for preventing these accidents; 2) to propose prevention measures to this company. Existing data on company occupational accidents were gathered and analysed to identify a work situation that appeared likely to cause AOL. This work situation was analysed in detail. Several risk factors were identified within this work situation, by way of interviews with 12 operators. These risk factors concerned various dimensions of the work situation, particularly its physical dimension (e.g. templates structure) and organisational dimension (e.g. parts availability). Interviews were conducted, focusing on risk factors perceived by operators and involving allo-confrontations based on accounts of four AOL occurring in this situation. Allo-confrontations were interviews confronting operators with a risk occupational situation that was accidental for one of their colleagues, the latter being absent from the interview. Results highlighted the fact that the work practices implemented are key factors in understanding these accidents. This study underlines the role of work practices in AOL causality and prevention. It also provides explanations associated with various work situation dimensions involving adoption of more or less safe work practices. AOL are serious and frequent in occupational situations. Injury claims analysis and interviews in an industrial company emphasise the specific characteristics of an occupational situation and of prevention actions forming the basis of an intervention. The need for a better understanding of factors affecting work practice is highlighted in relation to research.
NASA Technical Reports Server (NTRS)
Chu, W. P.; Chiou, E. W.; Larsen, J. C.; Thomason, L. W.; Rind, D.; Buglia, J. J.; Oltmans, S.; Mccormick, M. P.; Mcmaster, L. M.
1993-01-01
The operational inversion algorithm used for the retrieval of the water-vapor vertical profiles from the Stratospheric Aerosol and Gas Experiment II (SAGE II) occultation data is presented. Unlike the algorithm used for the retrieval of aerosol, O3, and NO2, the water-vapor retrieval algorithm accounts for the nonlinear relationship between the concentration versus the broad-band absorption characteristics of water vapor. Problems related to the accuracy of the computational scheme, the accuracy of the removal of other interfering species, and the expected uncertainty of the retrieved profile are examined. Results are presented on the error analysis of the SAGE II water vapor retrieval, indicating that the SAGE II instrument produced good quality water vapor data.
Block 2 SRM conceptual design studies. Volume 1, Book 1: Conceptual design package
NASA Technical Reports Server (NTRS)
Smith, Brad; Williams, Neal; Miller, John; Ralston, Joe; Richardson, Jennifer; Moore, Walt; Doll, Dan; Maughan, Jeff; Hayes, Fred
1986-01-01
The conceptual design studies of a Block 2 Solid Rocket Motor (SRM) require the elimination of asbestos-filled insulation and was open to alternate designs, such as case changes, different propellants, modified burn rate - to improve reliability and performance. Limitations were placed on SRM changes such that the outside geometry should not impact the physical interfaces with other Space Shuttle elements and should have minimum changes to the aerodynamic and dynamic characteristics of the Space Shuttle vehicle. Previous Space Shuttle SRM experience was assessed and new design concepts combined to define a valid approach to assured flight success and economic operation of the STS. Trade studies, preliminary designs, analyses, plans, and cost estimates are documented.
Research on Risk Management and Power Supplying Enterprise Control
NASA Astrophysics Data System (ADS)
Shen, Jianfei; Wang, Yige
2017-09-01
This paper derived from the background that electric power enterprises strengthen their risk management under requirements of the government. For the power industry, we explained the risk management theory, analysed current macro environment as well as basic situation, then classified and interpreted the main risks. In a case study on a power bureau, we established a risk management system based on deep understanding about the characteristics of its organization system and risk management function. Then, we focused on risks in operation as well as incorrupt government construction to give a more effective framework of the risk management system. Finally, we came up with the problems and specific countermeasures in risk management, which provided a reference for other electric power enterprises.
2000-hour cyclic endurance test of a laboratory model multipropellant resistojet
NASA Technical Reports Server (NTRS)
Morren, W. Earl; Sovey, James S.
1987-01-01
The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.
The Martian surface as imaged, sampled, and analyzed by the Viking landers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arvidson, R.E.; Gooding, J.L.; Moore, H.J.
1989-02-01
Data collected by two Viking landers are analyzed. Attention is given to the characteristics of the surface inferred from Lander imaging and meteorology data, physical and magnetic properties experiments, and both inorganic and organic analyses of Martian samples. Viking Lander 1 touched down on Chryse Planitia on July 20, 1976 and continued to operate for 2252 sols, until November 20, 1982. Lander 2 touched down about 6500 km away from Lander 1, on Utopia Planitia on September 3, 1976. The chemical compositions of sediments at the two landing sites are similar, suggesting an aeolian origin. The compositions suggest an iron-richmore » rock an are matched by various clays and salts. 89 refs.« less
A 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet
NASA Technical Reports Server (NTRS)
Morren, W. Earl; Sovey, James S.
1987-01-01
The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.
Poza Rica: 29 years of secondary recovery (in Spanish)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortega, H.G.
1981-03-01
One of the main objectives of the Mexican Goverment is the suitable exploitation of its hydrocarbon reservoirs. Therefore, the application of secondary recovery methods in those reservoirs sensitive to this method was increased. Petroleos Mexicanos has 27 systems of waterflooding in operation; 30% more than in 1976. The main objective is the continuous analysis of the optimum conditions, in order to optimize the efficiency of the waterflooding process, such as in the Tamabra formation in the Poza Rica field. A history is presented of the waterflooding process utilized in the Poza Rica field to increase the oil production from themore » Tamabra formation. Geology and reservoir characteristics, antecedents, producing well requirements, project development, future programs, and economic analyses are presented.« less
Comparison of chain sampling plans with single and double sampling plans
NASA Technical Reports Server (NTRS)
Stephens, K. S.; Dodge, H. F.
1976-01-01
The efficiency of chain sampling is examined through matching of operating characteristics (OC) curves of chain sampling plans (ChSP) with single and double sampling plans. In particular, the operating characteristics of some ChSP-0, 3 and 1, 3 as well as ChSP-0, 4 and 1, 4 are presented, where the number pairs represent the first and the second cumulative acceptance numbers. The fact that the ChSP procedure uses cumulative results from two or more samples and that the parameters can be varied to produce a wide variety of operating characteristics raises the question whether it may be possible for such plans to provide a given protection with less inspection than with single or double sampling plans. The operating ratio values reported illustrate the possibilities of matching single and double sampling plans with ChSP. It is shown that chain sampling plans provide improved efficiency over single and double sampling plans having substantially the same operating characteristics.
ERIC Educational Resources Information Center
Kwak, Misung; Oh, Insoo
2017-01-01
This study analysed the psychological and social characteristics of bullies involved in traditional and cyberbullying. The responses of 11,117 Korean elementary, middle, and high school students were analysed. Results indicate that the rate of traditional bullying was higher than the rate of cyberbullying. The four groups (traditional bullies,…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coleman, Charles J.; Edwards, Thomas B.
2005-04-30
The wet chemistry digestion method development for providing process control elemental analyses of the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Melter Feed Preparation Vessel (MFPV) samples is divided into two phases: Phase I consists of: (1) optimizing digestion methods as a precursor to elemental analyses by ICP-AES techniques; (2) selecting methods with the desired analytical reliability and speed to support the nine-hour or less turnaround time requirement of the WTP; and (3) providing baseline comparison to the laser ablation (LA) sample introduction technique for ICP-AES elemental analyses that is being developed at the Savannah River National Laboratory (SRNL).more » Phase II consists of: (1) Time-and-Motion study of the selected methods from Phase I with actual Hanford waste or waste simulants in shielded cell facilities to ensure that the methods can be performed remotely and maintain the desired characteristics; and (2) digestion of glass samples prepared from actual Hanford Waste tank sludge for providing comparative results to the LA Phase II study. Based on the Phase I testing discussed in this report, a tandem digestion approach consisting of sodium peroxide fusion digestions carried out in nickel crucibles and warm mixed-acid digestions carried out in plastic bottles has been selected for Time-and-Motion study in Phase II. SRNL experience with performing this analytical approach in laboratory hoods indicates that well-trained cell operator teams will be able to perform the tandem digestions in five hours or less. The selected approach will produce two sets of solutions for analysis by ICP-AES techniques. Four hours would then be allocated for performing the ICP-AES analyses and reporting results to meet the nine-hour or less turnaround time requirement. The tandem digestion approach will need to be performed in two separate shielded analytical cells by two separate cell operator teams in order to achieve the nine-hour or less turnaround time. Because of the simplicity of the warm mixed-acid method, a well-trained cell operator team may in time be able to perform both sets of digestions. However, having separate shielded cells for each of the methods is prudent to avoid overcrowding problems that would impede a minimal turnaround time.« less
NASA Astrophysics Data System (ADS)
Skocki, Krzysztof
2016-08-01
This paper summarizes the preliminary analyses of using existing remote sensing data, medium and high-resolution satellite and airborne data to define safe emergency landing and maneuvering areas to be used by small aircrafts operating from small airports and airfields in Poland. The pilots need to know such places in the interest of safe flight operations. In common practice, flying instructors typically show the student pilot fields around the airfield supposed to be suitable for emergency or precautionary landing (or ditching) in the initial phase of the training. Although it looks to cover the most basic needs, the problem still exists in relation to guest pilots. To fill this gap, the unified safety map document covering the safe emergency areas around the airfields is proposed in this research. Use of satellite high resolution data, as well as aerial photos, infrastructure information, with use of GIS tools (like buffer zones, distance, equal-time circles or position lines) enable to check the terrain around selected airfields and define possible areas suitable for emergency operations. In the second phase of work, selected areas will be described in terms of easy navigation, possible infrastructure around them, rescue possibilities, radio signal coverage, and others. The selected areas should be also checked for typical cover and surface hardness and stability (eg. with use of moisture estimation on the base of middle-resolution satellite data). Its planned to prepare one combined and separate sheets of the final map for various aircraft characteristics (`classes' of small Cessna-related, big Cessna-related, fast low-wing Diamond-like, two-engine Piper-like). The presented concept should highly increase the safety operations for small aviation in secondary airports and airfields, where the information available is limited. There is also a possibility to make a similar maps for `cruise', which means the areas with dense traffic between the airports/airfields.
Development of a fibre size-specific job-exposure matrix for airborne asbestos fibres.
Dement, J M; Kuempel, E D; Zumwalde, R D; Smith, R J; Stayner, L T; Loomis, D
2008-09-01
To develop a method for estimating fibre size-specific exposures to airborne asbestos dust for use in epidemiological investigations of exposure-response relations. Archived membrane filter samples collected at a Charleston, South Carolina asbestos textile plant during 1964-8 were analysed by transmission electron microscopy (TEM) to determine the bivariate diameter/length distribution of airborne fibres by plant operation. The protocol used for these analyses was based on the direct transfer method published by the International Standards Organization (ISO), modified to enhance fibre size determinations, especially for long fibres. Procedures to adjust standard phase contrast microscopy (PCM) fibre concentration measures using the TEM data in a job-exposure matrix (JEM) were developed in order to estimate fibre size-specific exposures. A total of 84 airborne dust samples were used to measure diameter and length for over 18,000 fibres or fibre bundles. Consistent with previous studies, a small proportion of airborne fibres were longer than >5 microm in length, but the proportion varied considerably by plant operation (range 6.9% to 20.8%). The bivariate diameter/length distribution of airborne fibres was expressed as the proportion of fibres in 20 size-specific cells and this distribution demonstrated a relatively high degree of variability by plant operation. PCM adjustment factors also varied substantially across plant operations. These data provide new information concerning the airborne fibre characteristics for a previously studied textile facility. The TEM data demonstrate that the vast majority of airborne fibres inhaled by the workers were shorter than 5 mum in length, and thus not included in the PCM-based fibre counts. The TEM data were used to develop a new fibre size-specific JEM for use in an updated cohort mortality study to investigate the role of fibre dimension in the development of asbestos-related lung diseases.
Finite element analyses of a linear-accelerator electron gun
NASA Astrophysics Data System (ADS)
Iqbal, M.; Wasy, A.; Islam, G. U.; Zhou, Z.
2014-02-01
Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.
Finite element analyses of a linear-accelerator electron gun.
Iqbal, M; Wasy, A; Islam, G U; Zhou, Z
2014-02-01
Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gun is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.
Aronow, Herbert D; Kennedy, Kevin F; Wayangankar, Siddharth A; Katzen, Barry T; Schneider, Peter A; Abou-Chebl, Alex; Rosenfield, Kenneth A
2016-09-01
Carotid artery revascularization was previously found to incrementally reduce stroke risk among patients with carotid stenosis treated with medical therapy. However, the frequency with which optimal medical therapies are used at discharge after carotid endarterectomy (CEA) and carotid artery stenting (CAS) is not known, and the influence of patient, operator, and hospital characteristics on the likelihood of prescription is poorly understood. In a retrospective cohort study of 23 112 patients undergoing CAS or CEA between January 2007 and June 2012 at US hospitals participating in the CARE registry (Carotid Artery Revascularization and Endarterectomy), we examined antiplatelet therapy and statin utilization at discharge. Hierarchical multivariable logistic regression was used in adjusted analyses. Antiplatelet agents and statins were prescribed at discharge in 99% and 78%, respectively, after CAS and 93% and 75%, respectively, after CEA. After adjustment, antiplatelet therapy was more often prescribed after CAS than CEA (odds ratio 2.4 [95% confidence interval 1.68-3.45]), but statin prescription was equally likely (odds ratio 1.11 [95% confidence interval 0.84-1.49]). Operator specialty (medical>radiology/surgery) and hospital community setting (suburban>urban>rural) independently predicted antiplatelet and statin agent use at discharge, whereas hospital geographic location (Northeast>Midwest/South>West) predicted use of statins but not antiplatelet therapy at discharge. US antiplatelet agent and statin discharge prescription rates were suboptimal after both CAS and CEA and varied by revascularization modality, operating physician specialty, and hospital characteristics. Improved and more uniform utilization after these procedures will be critical to the success of comprehensive stroke risk reduction efforts. © 2016 American Heart Association, Inc.
Code of Federal Regulations, 2010 CFR
2010-01-01
... the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... CONDITION OF FOOD CONTAINERS Miscellaneous § 42.142 Curve for obtaining Operating Characteristic (OC) curve...
Vitalis, V; Carfantan, C; Montcriol, A; Peyrefitte, S; Luft, A; Pouget, T; Sailliol, A; Ausset, S; Meaudre, E; Bordes, J
2018-05-01
Haemorrage is the leading cause of death after combat related injuries and bleeding management is the cornerstone of management of these casualties. French armed forces are deployed in Barkhane operation in the Sahel-Saharan Strip who represents an immense area. Since this constraint implies evacuation times beyond doctrinal timelines, an institutional decision has been made to deploy blood products on the battlefield and transfuse casualties before role 2 admission if indicated. The purpose of this study was to evaluate the transfusion practices on battlefield during the first year following the implementation of this policy. Prospective collection of data about combat related casualties categorized alpha evacuated to a role 2. Battlefield transfusion was defined as any transfusion of blood product (red blood cells, plasma, whole blood) performed by role 1 or Medevac team before admission at a role 2. Patients' characteristics, battlefield transfusions' characteristics and complications were analysed. During the one year study, a total of 29 alpha casualties were included during the period study. Twenty-eight could be analysed, 7/28 (25%) being transfused on battlefield, representing a total of 22 transfusion episodes. The most frequently blood product transfused was French lyophilized plasma (FLYP). Most of transfusion episodes occurred during medevac. Compared to non-battlefield transfused casualties, battlefield transfused casualties suffered more wounded anatomical regions (median number of 3 versus 2, p = 0.04), had a higher injury severity score (median ISS of 45 versus 25, p = 0,01) and were more often transfused at role 2, received more plasma units and whole blood units. There was no difference in evacuation time to role 2 between patients transfused on battlefield and non-transfused patients. There was no complication related to battlefield transfusions. Blood products transfusion onset on battlefield ranged from 75 min to 192 min after injury. Battlefield transfusion for combat-related casualties is a logistical challenge. Our study showed that such a program is feasible even in an extended area as Sahel-Saharan Strip operation theatre and reduces time to first blood product transfusion for alpha casualties. FLYP is the first line blood product on the battlefield. Copyright © 2017 Elsevier Ltd. All rights reserved.
Space nuclear power applied to electric propulsion
NASA Technical Reports Server (NTRS)
Vicente, F. A.; Karras, T.; Darooka, D.; Isenberg, L.
1989-01-01
Space reactor power systems with characteristics ideal for advanced spacecraft systems applications are discussed. These characteristics are: high power-to-weight ratio (15 to 33 W/kg); high volume density (high ballistic coefficient); no preferential orientation in orbit; long operational life; high reliability; and total launch and operational safety. These characteristics allow the use of electric propulsion to raise spacecraft from low earth parking orbits to operational orbits, greatly increasing the useful orbit payload for a given launch vehicle by eliminating the need for a separation injection stage. A proposed demonstration mission is described.
1980-06-16
AO-AOB 075 TENNESSEE UNIV KNOXVILLE DIEPT OF PSYCHOLOGY F/G 12/1 AoI FSTIMATION OF THE OPERATING CHARACTERISTICS WHEM THE TEST INFOR--ETCIUI ’JUN... testing . Applied Psychological Measurement, 1, 1977, pages 2 33 -24 7 (a). [121 Samejima, F. Applications of graded response models: The promise of the... PSYCHOLOGY F/S 12/1 FSTIMATION OF THE OPERATING CHARACTERISTICS WHEP- THE TEST INFOR- ETC(U) JUN GO F SAMEJIMA N00014-77-C-0360 UNCLASSIFIED RR-80-2 NL
Effects of Injection Scheme on Rotating Detonation Engine Operation
NASA Astrophysics Data System (ADS)
Chacon, Fabian; Duvall, James; Gamba, Mirko
2017-11-01
In this work, we experimentally investigate the operation and performance characteristics of a rotating detonation engine (RDE) operated with different fuel injection schemes and operating conditions. In particular, we investigate the detonation and operation characteristics produced with an axial flow injector configuration and semi-impinging injector configurations. These are compared to the characteristics produced with a canonical radial injection system (AFRL injector). Each type produces a different flowfield and mixture distribution, leading to a different detonation initiation, injector dynamic response, and combustor pressure rise. By using a combination of diagnostics, we quantify the pressure loses and gains in the system, the ability to maintain detonation over a range of operating points, and the coupling between the detonation and the air/fuel feed lines. We particularly focus on how this coupling affects both the stability and the performance of the detonation wave. This work is supported by the DOE/UTSR program under project DE-FE0025315.
NASA Technical Reports Server (NTRS)
Herman, Daniel A.; Soulas, George C.; Patterson, Michael J.
2009-01-01
The NASA s Evolutionary Xenon Thruster (NEXT) program is developing the next-generation ion propulsion system with significant enhancements beyond the state-of-the-art. The NEXT ion propulsion system provides improved mission capabilities for future NASA science missions to enhance and enable Discovery, New Frontiers, and Flagship-type NASA missions. As part of a comprehensive thruster service life assessment utilizing both testing and analyses, a Long-Duration Test (LDT) was initiated to validate and qualify the NEXT propellant throughput capability to a qualification-level of 450 kg, 1.5 times the mission-derived throughput requirement of 300 kg. This wear test is being conducted with a modified, flight-representative NEXT engineering model ion thruster, designated EM3. As of June 25, 2008, the thruster has accumulated 16,550 h of operation: the first 13,042 h at the thruster full-input-power of 6.9 kW with 3.52 A beam current and 1800 V beam power supply voltage. Operation since 13,042 h, i.e., the most recent 3,508 h, has been at an input power of 4.7 kW with 3.52 A beam current and 1180 V beam power supply voltage. The thruster has processed 337 kg of xenon (Xe) surpassing the NSTAR propellant throughput demonstrated during the extended life testing of the Deep Space 1 flight spare. The NEXT LDT has demonstrated a total impulse of 13.3 106 N s; the highest total impulse ever demonstrated by an ion thruster. Thruster plume diagnostics and erosion measurements are obtained periodically over the entire NEXT throttle table with input power ranging 0.5 to 6.9 kW. Observed thruster component erosion rates are consistent with predictions and the thruster service life assessment. There have not been any observed anomalous erosion and all erosion estimates indicate a thruster throughput capability that exceeds 750 kg of Xe, an equivalent of 36,500 h of continuous operation at the full-power operating condition. This paper presents the erosion measurements and plume diagnostic results for the NEXT LDT to date with emphasis on the change in thruster operating condition and resulting impact on wear characteristics. Ion optics grid-gap data, both cold and operating, are presented. Performance and wear predictions for the LDT throttle profile are presented.
Phylogenomics of Rhodobacteraceae reveals evolutionary adaptation to marine and non-marine habitats
Simon, Meinhard; Scheuner, Carmen; Meier-Kolthoff, Jan P; Brinkhoff, Thorsten; Wagner-Döbler, Irene; Ulbrich, Marcus; Klenk, Hans-Peter; Schomburg, Dietmar; Petersen, Jörn; Göker, Markus
2017-01-01
Marine Rhodobacteraceae (Alphaproteobacteria) are key players of biogeochemical cycling, comprise up to 30% of bacterial communities in pelagic environments and are often mutualists of eukaryotes. As ‘Roseobacter clade', these ‘roseobacters' are assumed to be monophyletic, but non-marine Rhodobacteraceae have not yet been included in phylogenomic analyses. Therefore, we analysed 106 genome sequences, particularly emphasizing gene sampling and its effect on phylogenetic stability, and investigated relationships between marine versus non-marine habitat, evolutionary origin and genomic adaptations. Our analyses, providing no unequivocal evidence for the monophyly of roseobacters, indicate several shifts between marine and non-marine habitats that occurred independently and were accompanied by characteristic changes in genomic content of orthologs, enzymes and metabolic pathways. Non-marine Rhodobacteraceae gained high-affinity transporters to cope with much lower sulphate concentrations and lost genes related to the reduced sodium chloride and organohalogen concentrations in their habitats. Marine Rhodobacteraceae gained genes required for fucoidan desulphonation and synthesis of the plant hormone indole 3-acetic acid and the compatible solutes ectoin and carnitin. However, neither plasmid composition, even though typical for the family, nor the degree of oligotrophy shows a systematic difference between marine and non-marine Rhodobacteraceae. We suggest the operational term ‘Roseobacter group' for the marine Rhodobacteraceae strains. PMID:28106881
Phylogenomics of Rhodobacteraceae reveals evolutionary adaptation to marine and non-marine habitats.
Simon, Meinhard; Scheuner, Carmen; Meier-Kolthoff, Jan P; Brinkhoff, Thorsten; Wagner-Döbler, Irene; Ulbrich, Marcus; Klenk, Hans-Peter; Schomburg, Dietmar; Petersen, Jörn; Göker, Markus
2017-06-01
Marine Rhodobacteraceae (Alphaproteobacteria) are key players of biogeochemical cycling, comprise up to 30% of bacterial communities in pelagic environments and are often mutualists of eukaryotes. As 'Roseobacter clade', these 'roseobacters' are assumed to be monophyletic, but non-marine Rhodobacteraceae have not yet been included in phylogenomic analyses. Therefore, we analysed 106 genome sequences, particularly emphasizing gene sampling and its effect on phylogenetic stability, and investigated relationships between marine versus non-marine habitat, evolutionary origin and genomic adaptations. Our analyses, providing no unequivocal evidence for the monophyly of roseobacters, indicate several shifts between marine and non-marine habitats that occurred independently and were accompanied by characteristic changes in genomic content of orthologs, enzymes and metabolic pathways. Non-marine Rhodobacteraceae gained high-affinity transporters to cope with much lower sulphate concentrations and lost genes related to the reduced sodium chloride and organohalogen concentrations in their habitats. Marine Rhodobacteraceae gained genes required for fucoidan desulphonation and synthesis of the plant hormone indole 3-acetic acid and the compatible solutes ectoin and carnitin. However, neither plasmid composition, even though typical for the family, nor the degree of oligotrophy shows a systematic difference between marine and non-marine Rhodobacteraceae. We suggest the operational term 'Roseobacter group' for the marine Rhodobacteraceae strains.
Cheng, Weixiao; Chen, Hong; Yan, ShuHai; Su, Jianqiang
2014-09-01
Short-chain fatty acids (SCFAs) can be produced by primary and waste activated sludge anaerobic fermentation. The yield and product spectrum distribution of SCFAs can be significantly affected by different initial pH values. However, most studies have focused on the physical and chemical aspects of SCFA production by waste activated sludge fermentation at different pH values. Information on the bacterial community structures during acidogenic fermentation is limited. In this study, comparisons of the bacterial communities during the co-substrate fermentation of food wastes and sewage sludge at different pH values were performed using the barcoded Illumina paired-end sequencing method. The results showed that different pH environments harbored a characteristic bacterial community, including sequences related to Lactobacillus, Prevotella, Mitsuokella, Treponema, Clostridium, and Ureibacillus. The most abundant bacterial operational taxonomic units in the different pH environments were those related to carbohydrate-degrading bacteria, which are associated with constituents of co-substrate fermentation. Further analyses showed that during organic matter fermentation, a core microbiota composed of Firmicutes, Proteobacteria, and Bacteroidetes existed. Comparison analyses revealed that the bacterial community during fermentation was significantly affected by the pH, and that the diverse product distribution was related to the shift in bacterial communities.
Dugré, Jules R; Guay, Jean-Pierre; Dumais, Alexandre
2018-05-01
Clinicians are often left with the difficult task of assessing and managing the risk of violent behaviors in individuals having command hallucinations, which may result in substantial rates of false positive or false negative. Moreover, findings on the association between command hallucinations and suicidal behaviors are limited. In an attempt to better understand compliance to this hallucinatory phenomenon, our objective was to identify the risk factors of compliance with self-harm command hallucinations. Secondary analyses from the MacArthur Study were performed on 82 participants with psychosis reporting such commands. Univariate logistic regression was used to examine the classification value of each characteristic associated with compliance with such commands. Seriousness and frequency of childhood physical abuse, a current comorbid substance use disorder, emotional distress, general symptomatology, history of compliance, and belief about compliance in the future were found to be significant risk factors of compliance with self-harm commands in the week preceding psychiatric inpatient. Multivariate analyses revealed that severity of childhood physical abuse, belief about compliance in the future, and a current comorbid substance use disorder were independent risk factors. The final model showed excellent classification accuracy as suggest by the receiver operating characteristic curve (AUC=0.84, 95% CI: 0.75-0.92, p<0.001). Our results suggest considerable clinical implications in regard to the assessment of risk of compliance to self-harm command hallucinations in individuals with psychosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Tu, Zhanhai; Xiao, Zebin; Zheng, Yingyan; Huang, Hongjie; Yang, Libin; Cao, Dairong
2018-01-01
Background Little is known about the value of computed tomography (CT) and magnetic resonance imaging (MRI) combined with diffusion-weighted imaging (DWI) in distinguishing malignant from benign skull-involved lesions. Purpose To evaluate the discriminative value of DWI combined with conventional CT and MRI for differentiating between benign and malignant skull-involved lesions. Material and Methods CT and MRI findings of 58 patients with pathologically proven skull-involved lesions (43 benign and 15 malignant) were retrospectively reviewed. Conventional CT and MRI characteristics and apparent diffusion coefficient (ADC) value of the two groups were evaluated and compared. Multivariate logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the differential performance of each parameter separately and together. Results The presence of cortical defects or break-through and ill-defined margins were associated with malignant skull-involved lesions (both P < 0.05). Malignant skull-involved lesions demonstrated a significantly lower ADC ( P = 0.016) than benign lesions. ROC curve analyses indicated that a combination of CT, MRI, and DWI with an ADC ≤ 0.703 × 10 -3 mm 2 /s showed optimal sensitivity, while DWI along showed optimal specificity of 88.4% in differentiating between benign and malignant skull-involved lesions. Conclusion The combination of CT, MRI, and DWI can help to differentiate malignant from benign skull-involved lesions. CT + MRI + DWI offers optimal sensitivity, while DWI offers optimal specificity.
Design and Operation of the Transformed National Healthy Start Evaluation.
Banks, Jamelle E; Dwyer, Maura; Hirai, Ashley; Ghandour, Reem M; Atrash, Hani K
2017-12-01
Purpose Improving pregnancy outcomes for women and children is one of the nation's top priorities. The Healthy Start (HS) program was created to address factors that contribute to high infant mortality rates (IMRs) and persistent disparities in IMRs. The program began in 1991 and was transformed in 2014 to apply lessons from emerging research, past evaluation findings, and expert recommendations. To understand the implementation and impact of the transformed program, there is a need for a robust and comprehensive evaluation. Description The national HS evaluation will include an implementation evaluation, which will describe program components that affect outcomes; a utilization evaluation, which will examine the characteristics of women and infants who did and did not utilize the program; and an outcome evaluation, which will assess the program's effectiveness with regard to producing expected outcomes among the target population. Data sources include the National HS Program Survey, a HS participant survey, and individual-level program data linked to vital records and the Pregnancy Risk Assessment Monitoring System (PRAMS) survey. Assessment Descriptive analyses will be used to examine differences in risk profiles between participants and non-participants, as well as to calculate penetration rates for high-risk women in respective service areas. Multivariable analyses will be used to determine the impact of the program on key outcomes and will explore variation by dose, type of services received, and grantee characteristics. Conclusion Evaluation findings are expected to inform program decisions and direction, including identification of effective program components that can be spread and scaled.
Grant, Stephen R
2006-01-01
SYNOPSIS Objective This study extends recent research on assessing the risk of intimate partner violence by determining the concurrent and predictive validity of a revised version of the Domestic Violence Screening Instrument (DVSI-R) and whether evidence of such validity is sustained independent of perpetrator demographic characteristics and forms of intimate violence. The analyses highlight violent incidents involving multiple victims as an indicator of “severe” violence. Previous research did not address these issues. Methods Data were analyzed on 14,970 assessments conducted in the State of Connecticut from September 1, 2004 through May 2, 2005. Hierarchical regression and receiver operating characteristic analyses were used to address the objectives of this research. Results The empirical findings support the concurrent and predictive validity of the DVSI-R and show that it is robust in its applicability. The findings further show that incidents involving multiple victims are highly associated with DVSI-R risk scores and recidivistic violence. Conclusion Validating and demonstrating the robustness of a risk assessment instrument is only a first step in preventing violence involving intimate partners or others in family or family-like relationships. The challenge is to train professionals responsible for addressing the problem of such violence to link valid risk assessments to well-crafted strategies of supervision and treatment so that the victimized or other potential victims are protected and perpetrators are held accountable for their actions. PMID:16827441
A Technique for the Assessment of Flight Operability Characteristics of Human Rated Spacecraft
NASA Technical Reports Server (NTRS)
Crocker, Alan
2010-01-01
In support of new human rated spacecraft development programs, the Mission Operations Directorate at NASA Johnson Space Center has implemented a formal method for the assessment of spacecraft operability. This "Spacecraft Flight Operability Assessment Scale" defines six key themes of flight operability, with guiding principles and goals stated for each factor. A standardized rating technique provides feedback that is useful to the operations, design and program management communities. Applicability of this concept across the program structure and life cycle is addressed. Examples of operationally desirable and undesirable spacecraft design characteristics are provided, as is a sample of the assessment scale product.
7 CFR 43.105 - Operating characteristics (OC) curves.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 43.105 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE COMMODITY STANDARDS AND STANDARD CONTAINER REGULATIONS STANDARDS FOR SAMPLING PLANS Sampling Plans § 43.105 Operating characteristics (OC...
The impact of airport characteristics on airport surface accidents and incidents.
Wilke, Sabine; Majumdar, Arnab; Ochieng, Washington Y
2015-06-01
Airport surface safety and in particular runway and taxiway safety is acknowledged globally as one of aviation's greatest challenges. To improve this key area of aviation safety, it is necessary to identify and understand the causal and contributing factors on safety occurrences. While the contribution of human factors, operations, and procedures has been researched extensively, the impact of the airport and its associated characteristics itself has received little or no attention. This paper introduces a novel methodology for risk and hazard assessment of airport surface operations, and models the relationships between airport characteristics, and (a) the rate of occurrences, (b) the severity of occurrences, and (c) the causal factors underlying occurrences. The results show for the first time how the characteristics of airports, and in particular its infrastructure and operations, influence the safety of surface operations. Copyright © 2015 Elsevier Ltd. and National Safety Council. Published by Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-10-01
... covered entity, to permit data analyses that relate to the health care operations of the respective..., trainees, or practitioners in areas of health care learn under supervision to practice or improve their... conducting cost-management and planning-related analyses related to managing and operating the entity...
Transportation-Driven Mars Surface Operations Supporting an Evolvable Mars Campaign
NASA Technical Reports Server (NTRS)
Toups, Larry; Brown, Kendall; Hoffman, Stephen J.
2015-01-01
This paper describes the results of a study evaluating options for supporting a series of human missions to a single Mars surface destination. In this scenario the infrastructure emplaced during previous visits to this site is leveraged in following missions. The goal of this single site approach to Mars surface infrastructure is to enable "Steady State" operations by at least 4 crew for up to 500 sols at this site. These characteristics, along with the transportation system used to deliver crew and equipment to and from Mars, are collectively known as the Evolvable Mars Campaign (EMC). Information in this paper is presented in the sequence in which it was accomplished. First, a logical buildup sequence of surface infrastructure was developed to achieve the desired "Steady State" operations on the Mars surface. This was based on a concept of operations that met objectives of the EMC. Second, infrastructure capabilities were identified to carry out this concept of operations. Third, systems (in the form of conceptual elements) were identified to provide these capabilities. This included top-level mass, power and volume estimates for these elements. Fourth, the results were then used in analyses to evaluate three options (18t, 27t, and 40t landed mass) of Mars Lander delivery capability to the surface. Finally, Mars arrival mass estimates were generated based upon the entry, descent, and landing requirements for inclusion in separate assessments of in-space transportation capabilities for the EMC.
SNAP 10A ESTIMATED ELECTRICAL CHARACTERISTICS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cooper, J.C.
1961-06-01
The electrical power characteristics of a SNAP 10A converter are estimated for given fractions of power degradation. Graphs are included showing the power characteristics for instantaneous transients from stabilized operation at the maximum efficiency point, and after system temperature stabilization at the operating point. Open-circuit emf's of the converter are estimated for instantaneous and temperature-stabilized cases. (D.L.C.)
Liang, He-Yue; Huang, Ya-Qin; Yang, Zhao-Xia; Ying-Ding; Zeng, Meng-Su; Rao, Sheng-Xiang
2016-07-01
To determine if magnetic resonance imaging (MRI) histogram analyses can help predict response to chemotherapy in patients with colorectal hepatic metastases by using response evaluation criteria in solid tumours (RECIST1.1) as the reference standard. Standard MRI including diffusion-weighted imaging (b=0, 500 s/mm(2)) was performed before chemotherapy in 53 patients with colorectal hepatic metastases. Histograms were performed for apparent diffusion coefficient (ADC) maps, arterial, and portal venous phase images; thereafter, mean, percentiles (1st, 10th, 50th, 90th, 99th), skewness, kurtosis, and variance were generated. Quantitative histogram parameters were compared between responders (partial and complete response, n=15) and non-responders (progressive and stable disease, n=38). Receiver operator characteristics (ROC) analyses were further analyzed for the significant parameters. The mean, 1st percentile, 10th percentile, 50th percentile, 90th percentile, 99th percentile of the ADC maps were significantly lower in responding group than that in non-responding group (p=0.000-0.002) with area under the ROC curve (AUCs) of 0.76-0.82. The histogram parameters of arterial and portal venous phase showed no significant difference (p>0.05) between the two groups. Histogram-derived parameters for ADC maps seem to be a promising tool for predicting response to chemotherapy in patients with colorectal hepatic metastases. • ADC histogram analyses can potentially predict chemotherapy response in colorectal liver metastases. • Lower histogram-derived parameters (mean, percentiles) for ADC tend to have good response. • MR enhancement histogram analyses are not reliable to predict response.
Characteristic operator functions for quantum input-plant-output models and coherent control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gough, John E.
We introduce the characteristic operator as the generalization of the usual concept of a transfer function of linear input-plant-output systems to arbitrary quantum nonlinear Markovian input-output models. This is intended as a tool in the characterization of quantum feedback control systems that fits in with the general theory of networks. The definition exploits the linearity of noise differentials in both the plant Heisenberg equations of motion and the differential form of the input-output relations. Mathematically, the characteristic operator is a matrix of dimension equal to the number of outputs times the number of inputs (which must coincide), but with entriesmore » that are operators of the plant system. In this sense, the characteristic operator retains details of the effective plant dynamical structure and is an essentially quantum object. We illustrate the relevance to model reduction and simplification definition by showing that the convergence of the characteristic operator in adiabatic elimination limit models requires the same conditions and assumptions appearing in the work on limit quantum stochastic differential theorems of Bouten and Silberfarb [Commun. Math. Phys. 283, 491-505 (2008)]. This approach also shows in a natural way that the limit coefficients of the quantum stochastic differential equations in adiabatic elimination problems arise algebraically as Schur complements and amounts to a model reduction where the fast degrees of freedom are decoupled from the slow ones and eliminated.« less
Hay, Greg; Cercarelli, L Rina
2004-04-01
To examine the accuracy of coin-operated breath analysers installed in licensed premises in the Perth metropolitan area. Two hundred licensed premises were contacted, which resulted in the location of 36 wall-mounted, coin-operated breath analysers. One instrument was removed prior to testing. These premises were then visited and the accuracy of the instruments was tested in situ using National Association of Testing Authorities Australia (NATA) certified 0.080% and 0.100% ethanol in nitrogen gas. The instruments were installed in the licensed premises as follows: 15 in the lounge bar, 10 in the main entrance, six in the public bar, two in the passageway to the toilets, and one in the male toilets. One licensed premise provided a handheld breath instrument. All instruments were accompanied by warning and operating instructions, but only five had any educational material. Only seven of the licensed premises had staff who had received any training in the operation of the wall-mounted instruments. Half of the licensees were unaware of the servicing requirements of the instruments. The testing found that only nine (25%) of the instruments provided acceptable results. The low level of accuracy of coin-operated breath analysers in the Perth metropolitan area is alarming and users should be informed of the potential inaccuracies. This paper, however, does not rule out that some wall-mounted breath analysing instruments may provide accurate results when properly maintained.
InGaAs/InP heteroepitaxial Schottky barrier diodes for terahertz applications
NASA Technical Reports Server (NTRS)
Bhapkar, Udayan V.; Li, Yongjun; Mattauch, Robert J.
1992-01-01
This paper explores the feasibility of planar, sub-harmonically pumped, anti-parallel InGaAs/InP heteroepitaxial Schottky diodes for terahertz applications. We present calculations of the (I-V) characteristics of such diodes using a numerical model that considers tunneling. We also present noise and conversion loss predictions of diode mixers operated at 500 GHz, and obtained from a multi-port mixer analysis, using the I-V characteristics predicted by our model. Our calculations indicate that InGaAs/InP heteroepitaxial Schottky barrier diodes are expected to have an I-V characteristic with an ideality factor comparable to that of GaAs Schottky diodes. However, the reverse saturation current of InGaAs/InP diodes is expected to be much greater than that of GaAs diodes. These predictions are confirmed by experiment. The mixer analyses predict that sub-harmonically pumped anti-parallel InGaAs/InP diode mixers are expected to offer a 2 dB greater conversion loss and a somewhat higher single sideband noise temperature than their GaAs counterparts. More importantly, the InGaAs/InP devices are predicted to require only one-tenth of the local oscillator power required by similar GaAs diodes.
Mills, Britain A.; Caetano, Raul; Bernstein, Ira H.
2011-01-01
This study compares the demographic predictors of items assessing attitudes towards drinking across Hispanic national groups. Data were from the 2006 Hispanic Americans Baseline Alcohol Survey (HABLAS), which used a multistage cluster sample design to interview 5,224 individuals randomly selected from the household population in Miami, New York, Philadelphia, Houston, and Los Angeles. Predictive invariance of demographic predictors of alcohol attitudes over four Hispanic national groups (Puerto Rican, Cuban, Mexican, and South/Central Americans) was examined using multiple-group seemingly unrelated probit regression. The analyses examined whether the influence of various demographic predictors varied across the Hispanic national groups in their regression coefficients, item intercepts, and error correlations. The hypothesis of predictive invariance was supported. Hispanic groups did not differ in how demographic predictors related to individual attitudinal items (regression slopes were invariant). In addition, the groups did not differ in attitudinal endorsement rates once demographic covariates were taken into account (item intercepts were invariant). Although Hispanic groups have different attitudes about alcohol, the influence of multiple demographic characteristics on alcohol attitudes operates similarly across Hispanic groups. Future models of drinking behavior in adult Hispanics need not posit moderating effects of group on the relation between these background characteristics and attitudes. PMID:25379120
Guo, Wan-liang; Zhan, Yang; Fang, Fang; Deng, Yan-bing; Zhao, Jun-gang
2018-01-01
Objective The aim of this study was to evaluate factors affecting the operating time for complete cyst excision and Roux-en-Y hepaticojejunostomy in paediatric cases of congenital choledochal malformation (CCM). Design A 3-year retrospective study was undertaken between January 2013 and December 2015 in four centres in China. Setting This involved a retrospective chart review of paediatric patients with CCM in four large hospitals in Southeast China. Participants Sixty-five paediatric patients with CCM were included in this study. We derived all available information on patient demographics, clinical characteristics, preoperative complications and surgical methods from the charts of all these patients. Interventions Univariate and multivariate logistic regression analyses were used to evaluate factors significantly affecting the operating time for complete cyst excision and Roux-en-Y hepaticojejunostomy in paediatric cases of CCM. Results Twenty-three of the 65 case surgeries were performed using laparoscopic technique, and 42 surgeries were performed by conventional open surgery. The median operating time was 215 min (range 120–430 min). The morphological subtype of CCM and the presence of cholecystitis or cholangitis were the only factors found to affect the operating time (p<0.05). Logistic regression analysis confirmed cholangitis as an independent risk factor. Conclusions The morphological subtype of CMM and the presence of cholecystitis or cholangitis are factors affecting the operating time for complete cyst excision and Roux-en-Y hepaticojejunostomy in paediatric cases of CCM, whereas cholangitis is an independent risk factor. PMID:29804066
Global atmospheric circulation statistics, 1000-1 mb
NASA Technical Reports Server (NTRS)
Randel, William J.
1992-01-01
The atlas presents atmospheric general circulation statistics derived from twelve years (1979-90) of daily National Meteorological Center (NMC) operational geopotential height analyses; it is an update of a prior atlas using data over 1979-1986. These global analyses are available on pressure levels covering 1000-1 mb (approximately 0-50 km). The geopotential grids are a combined product of the Climate Analysis Center (which produces analyses over 70-1 mb) and operational NMC analyses (over 1000-100 mb). Balance horizontal winds and hydrostatic temperatures are derived from the geopotential fields.
Finite element analyses of a linear-accelerator electron gun
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iqbal, M., E-mail: muniqbal.chep@pu.edu.pk, E-mail: muniqbal@ihep.ac.cn; Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049; Wasy, A.
Thermo-structural analyses of the Beijing Electron-Positron Collider (BEPCII) linear-accelerator, electron gun, were performed for the gun operating with the cathode at 1000 °C. The gun was modeled in computer aided three-dimensional interactive application for finite element analyses through ANSYS workbench. This was followed by simulations using the SLAC electron beam trajectory program EGUN for beam optics analyses. The simulations were compared with experimental results of the assembly to verify its beam parameters under the same boundary conditions. Simulation and test results were found to be in good agreement and hence confirmed the design parameters under the defined operating temperature. The gunmore » is operating continuously since commissioning without any thermal induced failures for the BEPCII linear accelerator.« less
Operational Suitability Guide. Volume 2. Templates
1990-05-01
Intended mission, and the required technical and operational characteristics. The mission must be adequately defined and key hardware and software ...operational availability. With the use of fault-tolerant computer hardware and software , the system R&M will significantly improve end-to-end...should Include both hardware and software elements, as appropriate. Unique characteristics or unique support concepts should be Identified if they result
Unstable behaviour of RPT when testing turbine characteristics in the laboratory
NASA Astrophysics Data System (ADS)
Nielsen, T. K.; Fjørtoft Svarstad, M.
2014-03-01
A reversible pump turbine is a machine that can operate in three modes of operation i.e. in pumping mode. in turbine mode and in phase compensating mode (idle speed). Reversible pump turbines have an increasing importance for regulation purposes for obtaining power balance in electric power systems. Especially in grids dominated by thermal energy. reversible pump turbines improve the overall power regulating ability. Increased use of renewables (wind-. wave- and tidal power plants) will utterly demand better regulation ability of the traditional water power systems. enhancing the use of reversible pump turbines. A reversible pump turbine is known for having incredible steep speed - flow characteristics. As the speed increases the flow decreases more than that of a Francis turbines with the same specific speed. The steep characteristics might cause severe stability problems in turbine mode of operation. Stability in idle speed is a necessity for phasing in the generator to the electric grid. In the design process of a power plant. system dynamic simulations must be performed in order to check the system stability. The turbine characteristics will have to be modelled with certain accuracy even before one knows the exact turbine design and have measured characteristics. A representation of the RPT characteristics for system dynamic simulation purposes is suggested and compared with measured characteristics. The model shows good agreement with RPT characteristics measured in The Waterpower Laboratory. Because of the S-shaped characteristics. there is a stability issue involved when measuring these characteristics. Without special measures. it is impossible to achieve stable conditions in certain operational points. The paper discusses the mechanism when using a throttle to achieve system stability. even if the turbine characteristics imply instability.
Experimental analysis of the flow pattern of a pump turbine model in pump mode
NASA Astrophysics Data System (ADS)
Guggenberger, Mark; Senn, Florian; Jaberg, Helmut; Gehrer, Arno; Sallaberger, Manfred; Widmer, Christian
2016-11-01
Reversible pump turbines are the only means to store primary energy in an highly efficient way. Within a short time their operation can be switched between the different operational regimes thus enhancing the stabilization of the electric grid. These qualities in combination with the operation even at off-design conditions offer a high flexibility to the energy market. However, pump turbines pass through operational regimes where their behaviour becomes unstable. One of these effects occurs when the flowrate is decreased continuously down to a minimum. This point is the physical limitation of the pump operation and is very difficult to predict properly by numerical design without a model test. The purpose of the present study is to identify the fluid mechanical phenomena leading to the occurrence of instabilities of pump turbines in pump mode. A reduced scale model of a ANDRITZ pump turbine was installed on a 4-quadrant test rig for the experimental investigation of unstable conditions in pump mode. The performed measurements are based on the IEC60193-standard. Characteristic measurements at a single guide vane opening were carried out to get a detailed insight into the instabilities in pump mode. The interaction between runner and guide vane was analysed by Particle Image Velocimetry. Furthermore, high-speed visualizations of the suction side part load flow and the suction recirculation were performed. Like never before the flow pattern in the draft tube cone became visible with the help of a high-speed camera by intentionally caused cavitation effects which allow a qualitative view on the flow pattern in the draft tube cone. Suction recirculation is observed in form of single vortices separating from each runner blade and stretching into the draft tube against the main flow direction. To find an explanation for the flow phenomena responsible for the appearance of the unstable head curve also characteristic velocity distributions on the pressure side were combined with high-speed visualizations on the suction side of the pump turbine model. The results enhance the comprehension of the physical background leading to the instability and improve the numerical predictability of the instability in pump mode.
NASA Astrophysics Data System (ADS)
Amanowicz, Łukasz; Wojtkowiak, Janusz
2017-11-01
In this paper the experimentally obtained flow characteristics of multi-pipe earth-to-air heat exchangers (EAHEs) were used to validate the EAHE flow performance numerical model prepared by means of CFD software Ansys Fluent. The cut-cell meshing and the k-ɛ realizable turbulence model with default coefficients values and enhanced wall treatment was used. The total pressure losses and airflow in each pipe of multi-pipe exchangers was investigated both experimentally and numerically. The results show that airflow in each pipe of multi-pipe EAHE structures is not equal. The validated numerical model can be used for a proper designing of multi-pipe EAHEs from the flow characteristics point of view. The influence of EAHEs geometrical parameters on the total pressure losses and airflow division between the exchanger pipes can be also analysed. Usage of CFD for designing the EAHEs can be helpful for HVAC engineers (Heating Ventilation and Air Conditioning) for optimizing the geometrical structure of multi-pipe EAHEs in order to save the energy and decrease operational costs of low-energy buildings.
Hu, Kai; Dars, Abdul Ghani; Liu, Qiudou; Xie, Bijun; Sun, Zhida
2018-08-01
Maturity has important effects on the phytochemical and biochemical characteristics of fruits. It affects the quality, nutritional value, harvest time and commercial operations. In this study, Keitt, Sensation and Xiangya mango cultivars in four distinct stages from southwest China were evaluated for their phytochemical profiling and antioxidant activities in real time. Furthermore, the biochemical characteristics indices polyphenol oxidase (PPO), peroxidase (POD), superoxide dismutase (SOD) and pectin methylesterase (PME) activities were determined. Antioxidant compounds such as vitamin C, total phenolic, total flavonoid and total carotenoid content were also analysed. A total of 34 phenolic compounds were identified and quantitatively monitored by UPLC-ESI-QTOF-MS. Consecutive degradation of phenolic acids and its derivatives were observed upon maturity. We found that in addition to carotenoids, phenolic acids could also be used as a measurement index of maturity in mango. Mango juices and its phenolic extracts may be used as potential prebiotics for modulating probiotic proliferation. Copyright © 2018. Published by Elsevier Ltd.
Surfactant effects on alpha factors in full-scale wastewater aeration systems.
Rosso, D; Larson, L E; Stenstrom, M K
2006-01-01
Aeration is an essential process in the majority of wastewater treatment processes, and accounts for the largest fraction of plant energy costs. Aeration systems can achieve wastewater oxygenation by shearing the surface (surface aerators) or releasing bubbles at the bottom of the tank (coarse- or fine-bubble aerators). Surfactants accumulate on gas-liquid interfaces and reduce mass transfer rates. This reduction in general is larger for fine-bubble aerators. This study was conducted to evaluate mass transfer effects on the characterization and specification of aeration systems in clean and process water conditions. Tests at different interfacial turbulence regimes were analysed, showing higher gas transfer depression for lower turbulence regimes. Higher turbulence regimes can offset contamination effects, at the expense of operating efficiency. This phenomenon is characteristic of surface aerators and coarse bubble diffusers and is here discussed. The results explain the variability of alpha factors measured at small scale, due to uncontrolled energy density. Results are also reported in dimensionless empirical correlations that describe mass transfer as a function of physiochemical and geometrical characteristics of the aeration process.
Climatic extremes improve predictions of spatial patterns of tree species
Zimmermann, N.E.; Yoccoz, N.G.; Edwards, T.C.; Meier, E.S.; Thuiller, W.; Guisan, Antoine; Schmatz, D.R.; Pearman, P.B.
2009-01-01
Understanding niche evolution, dynamics, and the response of species to climate change requires knowledge of the determinants of the environmental niche and species range limits. Mean values of climatic variables are often used in such analyses. In contrast, the increasing frequency of climate extremes suggests the importance of understanding their additional influence on range limits. Here, we assess how measures representing climate extremes (i.e., interannual variability in climate parameters) explain and predict spatial patterns of 11 tree species in Switzerland. We find clear, although comparably small, improvement (+20% in adjusted D2, +8% and +3% in cross-validated True Skill Statistic and area under the receiver operating characteristics curve values) in models that use measures of extremes in addition to means. The primary effect of including information on climate extremes is a correction of local overprediction and underprediction. Our results demonstrate that measures of climate extremes are important for understanding the climatic limits of tree species and assessing species niche characteristics. The inclusion of climate variability likely will improve models of species range limits under future conditions, where changes in mean climate and increased variability are expected.
Li, Xiang; Huang, Yong; Yuan, Yi; Bi, Zhen; Liu, Xin
2017-08-01
The differences in the physiological characteristics between AOB and ANAMMOX bacteria lead to suboptimal performance when used in a single reactor. In this study, aerobic and anaerobic zones with different survival environments were constructed in a single reactor to realize partitioned culture of AOB and ANAMMOX bacteria. An external air-lift reflux system was formed which used the exhaust from the aeration zone as power to return the effluent to the aeration zone. The reflux system effectively alleviated the large pH fluctuations and promoted NO 2 - -N to rapidly use by ANAMMOX bacteria, effectively inhibiting the activity of NOB. After 95d of running, the nitrogen removal rate increased from the initial 0.21kg/(m 3 ·d) to 3.1kg/(m 3 ·d). FISH analyses further demonstrated that AOB and ANAMMOX bacteria acquired efficient enrichment in the corresponding zone. Thus, this type of integrative reactor may create the environments needed for the partial nitritation-ANAMMOX processing. Copyright © 2017 Elsevier Ltd. All rights reserved.
Investigation of dynamic characteristics of a turbine-propeller engine
NASA Technical Reports Server (NTRS)
Oppenheimer, Frank L; Jacques, James R
1951-01-01
Time constants that characterize engine speed response of a turbine-propeller engine over the cruising speed range for various values of constant fuel flow and constant blade angle were obtained both from steady-state characteristics and from transient operation. Magnitude of speed response to changes in fuel flow and blade angle was investigated and is presented in the form of gain factors. Results indicate that at any given value of speed in the engine cruising speed range, time constants obtained both from steady-state characteristics and from transient operation agree satisfactorily for any given constant fuel flow, whereas time constants obtained from transient operation exceed time constants obtained from steady-state characteristics by approximately 14 percent for any given blade angle.
NASA Astrophysics Data System (ADS)
Attada, Raju; Parekh, Anant; Chowdary, J. S.; Gnanaseelan, C.
2018-04-01
This work is the first attempt to produce a multi-year downscaled regional reanalysis of the Indian summer monsoon (ISM) using the National Centers for Environmental Prediction (NCEP) operational analyses and Atmospheric Infrared Sounder (AIRS) version 5 temperature and moisture retrievals in a regional model. Reanalysis of nine monsoon seasons (2003-2011) are produced in two parallel setups. The first set of experiments simply downscale the original NCEP operational analyses, whilst the second one assimilates the AIRS temperature and moisture profiles. The results show better representation of the key monsoon features such as low level jet, tropical easterly jet, subtropical westerly jet, monsoon trough and the spatial pattern of precipitation when AIRS profiles are assimilated (compared to those without AIRS data assimilation). The distribution of temperature, moisture and meridional gradients of dynamical and thermodynamical fields over the monsoon region are better represented in the reanalysis that assimilates AIRS profiles. The change induced by AIRS data on the moist and thermodynamic conditions results in more realistic rendering of the vertical shear associated with the monsoon, which in turn leads to a proper moisture transport and the moist convective feedback. This feedback benefits the representation of the regional monsoon characteristics, the monsoon dynamics and the moist convective processes on the seasonal time scale. This study emphasizes the use of AIRS soundings for downscaling of ISM representation in a regional reanalysis.
Kapadia, F; Siconolfi, D E; Barton, S; Olivieri, B; Lombardo, L; Halkitis, P N
2013-06-01
Associations between social support network characteristics and sexual risk among racially/ethnically diverse young men who have sex with men (YMSM) were examined using egocentric network data from a prospective cohort study of YMSM (n = 501) recruited in New York City. Bivariate and multivariable logistic regression analyses examined associations between social support network characteristics and sexual risk taking behaviors in Black, Hispanic/Latino, and White YMSM. Bivariate analyses indicated key differences in network size, composition, communication frequency and average relationship duration by race/ethnicity. In multivariable analyses, controlling for individual level sociodemographic, psychosocial and relationship factors, having a sexual partner in one's social support network was associated with unprotected sexual behavior for both Hispanic/Latino (AOR = 3.90) and White YMSM (AOR = 4.93). Further examination of key network characteristics across racial/ethnic groups are warranted in order to better understand the extant mechanisms for provision of HIV prevention programming to racially/ethnically diverse YMSM at risk for HIV.
Low power DC arcjet operation with hydrogen/nitrogen/ammonia mixtures
NASA Technical Reports Server (NTRS)
Hardy, Terry L.; Curran, Francis M.
1987-01-01
The effect of gas composition and ambient pressure on arcjet operation was determined. Arcjet operation in different facilities was also compared to determine the validity of tests in small facilities. Volt-ampere characteristics were determined for an arcjet using hydrogen/nitrogen mixtures (simulating both ammonia and hydrazine), hydrogen/nitrogen/ammonia mixtures, and pure ammonia as propellants at various flow rates. The arcjet had a typical performance of 450 sec specific impulse at 1 kW with hydrogen/nitrogen mixures. It was determined that the amount of ammonia present in the gas stream had a significant effect on the arcjet volt-ampere characteristics. Also, hydrogen/nitrogen mixtures simulating ammonia gave arc characteristics approximately the same as those of pure ammonia. Finally, no differences in arc volt-ampere characteristics were seen between low and high ambient pressure operation in the same facility. A 3 to 5 V difference was seen when different facilities were compared, but this difference was probably due to differences in the voltage drops across the current connections, and not due to arcjet operational differences in the two facilities.
Low power dc arcjet operation with hydrogen/nitrogen/ammonia mixtures
NASA Technical Reports Server (NTRS)
Hardy, Terry L.; Curran, Francis M.
1986-01-01
The effect of gas composition and ambient pressure on arcjet operation was determined. Arcjet operation in different facilities was also compared to determine the validity of tests in small facilities. Volt-ampere characteristics were determined for an arcjet using hydrogen/nitrogen mixtures (simulating both ammonia and hydrazine), hydrogen/nitrogen/ammonia mixtures, and pure ammonia as propellants at various flow rates. The arcjet had a typical performance of 450 sec specific impulse at 1 kW with hydrogen/nitrogen mixtures. It was determined that the amount of ammonia present in the gas stream had a significant effect on the arcjet volt-ampere characteristics. Also, hydrogen/nitrogen mixtures simulating ammonia gave arc characteristics approximately the same as those of pure ammonia. Finally, no differences in arc volt-ampere characteristics were seen between low and high ambient pressure operation in the same facility. A 3 to 5 V difference was seen when different facilities were compared, but this difference was probably due to differences in the voltage drops across the current connections, and not due to arcjet operational differences in the two facilities.
Switch Panel wear loading - a parametric study regarding governing train operational factors
NASA Astrophysics Data System (ADS)
Hiensch, E. J. M.; Burgelman, N.
2017-09-01
The acting forces and resulting material degradation at the running surfaces of wheels and rail are determined by vehicle, track, interface and operational characteristics. To effectively manage the experienced wear, plastic deformation and crack development at wheels and rail, the interaction between vehicle and track demands a system approach both in maintenance and in design. This requires insight into the impact of train operational parameters on rail- and wheel degradation, in particular at switches and crossings due to the complex dynamic behaviour of a railway vehicle at a turnout. A parametric study was carried out by means of vehicle-track simulations within the VAMPIRE® multibody simulation software, performing a sensitivity analysis regarding operational factors and their impact on expected switch panel wear loading. Additionally, theoretical concepts were cross-checked with operational practices by means of a case study in response to a dramatic change in lateral rail wear development at specific switches in Dutch track. Data from train operation, track maintenance and track inspection were analysed, providing further insight into the operational dependencies. From the simulations performed in this study, it was found that switch rail lateral wear loading at the diverging route of a 1:9 type turnout is significantly influenced by the level of wheel-rail friction and to a lesser extent by the direction of travel (facing or trailing). The influence of other investigated parameters, being vehicle speed, traction, gauge widening and track layout is found to be small. Findings from the case study further confirm the simulation outcome. This research clearly demonstrates the contribution flange lubrication can have in preventing abnormal lateral wear at locations where the wheel-rail interface is heavily loaded.
Analysis of self-oscillating dc-to-dc converters
NASA Technical Reports Server (NTRS)
Burger, P.
1974-01-01
The basic operational characteristics of dc-to-dc converters are analyzed along with the basic physical characteristics of power converters. A simple class of dc-to-dc power converters are chosen which could satisfy any set of operating requirements, and three different controlling methods in this class are described in detail. Necessary conditions for the stability of these converters are measured through analog computer simulation whose curves are related to other operational characteristics, such as ripple and regulation. Further research is suggested for the solution of absolute stability and efficient physical design of this class of power converters.
Do Work Characteristics Predict Health Deterioration Among Employees with Chronic Diseases?
de Wind, Astrid; Boot, Cécile R L; Sewdas, Ranu; Scharn, Micky; van den Heuvel, Swenne G; van der Beek, Allard J
2018-06-01
Purpose In our ageing workforce, the increasing numbers of employees with chronic diseases are encouraged to prolong their working lives. It is important to prevent health deterioration in this vulnerable group. This study aims to investigate whether work characteristics predict health deterioration over a 3-year period among employees with (1) chronic diseases, and, more specifically, (2) musculoskeletal and psychological disorders. Methods The study population consisted of 5600 employees aged 45-64 years with a chronic disease, who participated in the Dutch Study on Transitions in Employment, Ability and Motivation (STREAM). Information on work characteristics was derived from the baseline questionnaire. Health deterioration was defined as a decrease in general health (SF-12) between baseline and follow-up (1-3 years). Crude and adjusted logistic regression analyses were performed to investigate prediction of health deterioration by work characteristics. Subgroup analyses were performed for employees with musculoskeletal and psychological disorders. Results At follow-up, 19.2% of the employees reported health deterioration (N = 1075). Higher social support of colleagues or supervisor predicted health deterioration in the crude analyses in the total group, and the groups with either musculoskeletal or psychological disorders (ORs 1.11-1.42). This effect was not found anymore in the adjusted analyses. The other work characteristics did not predict health deterioration in any group. Conclusions This study did not support our hypothesis that work characteristics predict health deterioration among employees with chronic diseases. As our study population succeeded continuing employment to 45 years and beyond, it was probably a relatively healthy selection of employees.
FINANCIAL ANALYSIS OF CURRENT OPERATIONS OF COLLEGES AND UNIVERSITIES.
ERIC Educational Resources Information Center
SWANSON, JOHN E.; AND OTHERS
TECHNIQUES FOR DEVELOPING FINANCIAL AND RELATED COST-EFFECTIVENESS DATA FOR PUBLIC AND PRIVATELY SUPPORTED AMERICAN COLLEGES AND UNIVERSITIES WERE STUDIED TO FORMULATE PRINCIPLES, PROCEDURES, AND STANDARDS FOR THE ACCUMULATION AND ANALYSES OF CURRENT OPERATING COSTS. AFTER SEPARATE ANALYSES OF INSTITUTIONAL PROCEDURES AND REPORTS, ANALYTIC UNITS…
Health economics and outcomes methods in risk-based decision-making for blood safety.
Custer, Brian; Janssen, Mart P
2015-08-01
Analytical methods appropriate for health economic assessments of transfusion safety interventions have not previously been described in ways that facilitate their use. Within the context of risk-based decision-making (RBDM), health economics can be important for optimizing decisions among competing interventions. The objective of this review is to address key considerations and limitations of current methods as they apply to blood safety. Because a voluntary blood supply is an example of a public good, analyses should be conducted from the societal perspective when possible. Two primary study designs are recommended for most blood safety intervention assessments: budget impact analysis (BIA), which measures the cost to implement an intervention both to the blood operator but also in a broader context, and cost-utility analysis (CUA), which measures the ratio between costs and health gain achieved, in terms of reduced morbidity and mortality, by use of an intervention. These analyses often have important limitations because data that reflect specific aspects, for example, blood recipient population characteristics or complication rates, are not available. Sensitivity analyses play an important role. The impact of various uncertain factors can be studied conjointly in probabilistic sensitivity analyses. The use of BIA and CUA together provides a comprehensive assessment of the costs and benefits from implementing (or not) specific interventions. RBDM is multifaceted and impacts a broad spectrum of stakeholders. Gathering and analyzing health economic evidence as part of the RBDM process enhances the quality, completeness, and transparency of decision-making. © 2015 AABB.
Low degree of satisfactory individual pain relief in post-operative pain trials.
Geisler, A; Dahl, J B; Karlsen, A P H; Persson, E; Mathiesen, O
2017-01-01
The majority of clinical trials regarding post-operative pain treatment focuses on the average analgesic efficacy, rather than on efficacy in individual patients. It has been argued, that in acute pain trials, the underlying distributions are often skewed, which makes the average unfit as the only way to measure efficacy. Consequently, dichotomised, individual responder analyses using a predefined 'favourable' response, e.g. Visual Analogue Scale (VAS) pain scores ≤ 30, have recently been suggested as a more clinical relevant outcome. We re-analysed data from 16 randomised controlled trials of post-operative pain treatment and from meta-analyses of a systematic review regarding hip arthroplasty. The predefined success criterion was that at least 80% of patients in active treatment groups should obtain VAS < 30 at 6 and 24 h post-operatively. In the analysis of data from the randomised controlled trials, we found that at 6 h post-operatively, 50% (95% CI: 31-69) of patients allocated to active treatment reached the success criterion for pain at rest and 14% (95% CI: 5-34) for pain during mobilisation. At 24 h post-operatively, 60% (95% CI: 38-78) of patients allocated to active treatment reached the success criterion for pain at rest, and 15% (95% CI: 5-36) for pain during mobilisation. Similar results were found for trials from the meta-analyses. Our results indicate that for conventional, explanatory trials of post-operative pain, individual patient's achievement of a favourable response to analgesic treatment is rather low. Future pragmatic clinical trials should focus on both average pain levels and individual responder analyses in order to promote effective pain treatment at the individually patient level. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Monothermal caloric screening test performance: a relative operating characteristic curve analysis.
Murnane, Owen D; Akin, Faith W; Lynn, Susan G; Cyr, David G
2009-06-01
The objective of the present study was to evaluate the performance of the monothermal caloric screening test in a large sample of patients. A retrospective analysis of the medical records of 1002 consecutive patients who had undergone vestibular assessment at the Mayo Clinic during the years 1989 and 1990 was conducted. Patients with incomplete alternate binaural bithermal (ABB) caloric testing, congenital or periodic alternating nystagmus, or bilateral vestibular loss were excluded from the study. Clinical decision theory analyses (relative operating characteristic curves) were used to determine the accuracy with which the monothermal warm (MWST) and monothermal cool (MCST) caloric screening tests predicted the results of the ABB caloric test. Cumulative distributions were constructed as a function of the cutoff points for monothermal interear difference (IED) to select the cutoff point associated with any combination of true-positive and false-positive rates. Both MWST and MCST performed well above chance level. The test performance for the MWST was significantly better than that of the MCST for three of the four ABB gold standards. A 10% IED cutoff point for the MWST yielded a false-negative rate of either 1% (UW >or=25%) or 3% (UW >or=20%). The use of a 10% IED (UW >or=25%) for the MWST would have resulted in a 40% reduction (N = 294) in the number of ABB caloric tests performed on patients without a unilateral weakness. The results of this study indicated that the MWST decreases test time without sacrificing the sensitivity of the ABB caloric test.
Schlattmann, Peter; Verba, Maryna; Dewey, Marc; Walther, Mario
2015-01-01
Bivariate linear and generalized linear random effects are frequently used to perform a diagnostic meta-analysis. The objective of this article was to apply a finite mixture model of bivariate normal distributions that can be used for the construction of componentwise summary receiver operating characteristic (sROC) curves. Bivariate linear random effects and a bivariate finite mixture model are used. The latter model is developed as an extension of a univariate finite mixture model. Two examples, computed tomography (CT) angiography for ruling out coronary artery disease and procalcitonin as a diagnostic marker for sepsis, are used to estimate mean sensitivity and mean specificity and to construct sROC curves. The suggested approach of a bivariate finite mixture model identifies two latent classes of diagnostic accuracy for the CT angiography example. Both classes show high sensitivity but mainly two different levels of specificity. For the procalcitonin example, this approach identifies three latent classes of diagnostic accuracy. Here, sensitivities and specificities are quite different as such that sensitivity increases with decreasing specificity. Additionally, the model is used to construct componentwise sROC curves and to classify individual studies. The proposed method offers an alternative approach to model between-study heterogeneity in a diagnostic meta-analysis. Furthermore, it is possible to construct sROC curves even if a positive correlation between sensitivity and specificity is present. Copyright © 2015 Elsevier Inc. All rights reserved.
Chanani, Ankit; Adhikari, Haridas Das
2017-01-01
Differential diagnosis of periapical cysts and granulomas is required as their treatment modalities are different. The aim of this study was to evaluate the efficacy of cone beam computed tomography (CBCT) in the differential diagnosis of periapical cysts from granulomas. A single-centered observational study was carried out in the Department of Conservative Dentistry and Endodontics, Dr. R. Ahmed Dental College and Hospital, using CBCT and dental operating microscope. Forty-five lesions were analyzed using CBCT scans. One evaluator analyzed each CBCT scan for the presence of the following six characteristic radiological features: cyst like-location, shape, periphery, internal structure, effect on the surrounding structures, and cortical plate perforation. Another independent evaluator analyzed the CBCT scans. This process was repeated after 6 months, and inter- and intrarater reliability of CBCT diagnoses was evaluated. Periapical surgeries were performed and tissue samples were obtained for histopathological analysis. To evaluate the efficacy, CBCT diagnoses were compared with histopathological diagnoses, and six receiver operating characteristic (ROC) curve analyses were conducted. ROC curve, Cronbach's alpha (α) test, and Cohen Kappa (κ) test were used for statistical analysis. Both inter- and intrarater reliability were excellent (α = 0.94, κ = 0.75 and 0.77, respectively). ROC curve with regard to ≥4 positive findings revealed the highest area under curve (0.66). CBCT is moderately accurate in the differential diagnosis of periapical cysts and granulomas.
Wiglusz, Mariusz S; Landowski, Jerzy; Cubała, Wiesław J
2018-05-24
Anxiety disorders are frequent comorbid disorders in patients with epilepsy (PWEs). The availability of validated screening instruments to detect anxiety disorders in PWEs is limited. The aim of the present study was to validate the Polish version of the Hospital Anxiety and Depression Scale (HADS) in adult PWEs for the detection of anxiety disorders. A total of 96 outpatients with epilepsy completed the self-reported symptom scale, the HADS, and were diagnosed using the structured clinical interview for Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision (DSM-IV-TR) axis I disorders (SCID-I). The sensitivity, specificity, positive and negative predictive values (PPV and NPV, respectively), and receiver operating characteristic (ROC) curves were assessed to determine the optimal threshold scores for the HADS anxiety subscale (HADS-A). Receiver operating characteristic analyses showed areas under the curve at 80.8%. For diagnoses of anxiety disorder, the HADS-A demonstrated the best psychometric properties for a cutoff score ≥10 with sensitivity of 81.3%, specificity of 70.0%, PPV of 31.5%, and NPV of 94.9%. The HADS-A proved to be a valid and reliable psychometric instrument in terms of screening for anxiety disorders in our sample of PWEs. In the epilepsy setting, the HADS-A maintains adequate sensitivity, acceptable specificity, and high NPV but low PPV for diagnosing anxiety disorders with an optimum cutoff score ≥10. Copyright © 2018 Elsevier Inc. All rights reserved.
Diagnostic performance of BMI percentiles to identify adolescents with metabolic syndrome.
Laurson, Kelly R; Welk, Gregory J; Eisenmann, Joey C
2014-02-01
To compare the diagnostic performance of the Centers for Disease Control and Prevention (CDC) and FITNESSGRAM (FGram) BMI standards for quantifying metabolic risk in youth. Adolescents in the NHANES (n = 3385) were measured for anthropometric variables and metabolic risk factors. BMI percentiles were calculated, and youth were categorized by weight status (using CDC and FGram thresholds). Participants were also categorized by presence or absence of metabolic syndrome. The CDC and FGram standards were compared by prevalence of metabolic abnormalities, various diagnostic criteria, and odds of metabolic syndrome. Receiver operating characteristic curves were also created to identify optimal BMI percentiles to detect metabolic syndrome. The prevalence of metabolic syndrome in obese youth was 19% to 35%, compared with <2% in the normal-weight groups. The odds of metabolic syndrome for obese boys and girls were 46 to 67 and 19 to 22 times greater, respectively, than for normal-weight youth. The receiver operating characteristic analyses identified optimal thresholds similar to the CDC standards for boys and the FGram standards for girls. Overall, BMI thresholds were more strongly associated with metabolic syndrome in boys than in girls. Both the CDC and FGram standards are predictive of metabolic syndrome. The diagnostic utility of the CDC thresholds outperformed the FGram values for boys, whereas FGram standards were slightly better thresholds for girls. The use of a common set of thresholds for school and clinical applications would provide advantages for public health and clinical research and practice.
Na, Min Kyun; Won, Yu Deok; Kim, Choong Hyun; Kim, Jae Min; Cheong, Jin Hwan; Ryu, Je Il; Han, Myung-Hoon
2017-01-01
Hydrocephalus is a frequent complication following subarachnoid hemorrhage. Few studies investigated the association between laboratory parameters and shunt-dependent hydrocephalus. This study aimed to investigate the variations of laboratory parameters after subarachnoid hemorrhage. We also attempted to identify predictive laboratory parameters for shunt-dependent hydrocephalus. Multiple imputation was performed to fill the missing laboratory data using Bayesian methods in SPSS. We used univariate and multivariate Cox regression analyses to calculate hazard ratios for shunt-dependent hydrocephalus based on clinical and laboratory factors. The area under the receiver operating characteristic curve was used to determine the laboratory risk values predicting shunt-dependent hydrocephalus. We included 181 participants with a mean age of 54.4 years. Higher sodium (hazard ratio, 1.53; 95% confidence interval, 1.13-2.07; p = 0.005), lower potassium, and higher glucose levels were associated with higher shunt-dependent hydrocephalus. The receiver operating characteristic curve analysis showed that the areas under the curve of sodium, potassium, and glucose were 0.649 (cutoff value, 142.75 mEq/L), 0.609 (cutoff value, 3.04 mmol/L), and 0.664 (cutoff value, 140.51 mg/dL), respectively. Despite the exploratory nature of this study, we found that higher sodium, lower potassium, and higher glucose levels were predictive values for shunt-dependent hydrocephalus from postoperative day (POD) 1 to POD 12-16 after subarachnoid hemorrhage. Strict correction of electrolyte imbalance seems necessary to reduce shunt-dependent hydrocephalus. Further large studies are warranted to confirm our findings.
Zuo, Lugen; Li, Yi; Wang, Honggang; Zhu, Weiming; Zhang, Wei; Gong, Jianfeng; Li, Ning; Li, Jieshou
2015-08-01
Postoperative intra-abdominal septic complications are difficult to manage in Crohn's disease, which makes prevention especially important. The purpose of this study was to examine the risk factors for intra-abdominal septic complications after primary anastomosis for Crohn's disease and to seek a practical predictive index for intra-abdominal septic complications. This was a retrospective study. The study was conducted in a tertiary referral hospital. Based on a computerized database of 344 patients with Crohn's disease who underwent primary anastomosis between 2004 and 2013, the patients were placed into an intra-abdominal septic complications group and a group without intra-abdominal septic complications. Univariate and multivariate analyses were performed to identify risk factors, and the predictive accuracy of possible predictors was assessed using receiver operating characteristic curves. Overall, 39 patients (11.34%) developed intra-abdominal septic complications. Preoperative C-reactive protein level >10 mg/L was found to be an independent risk factor (p < 0.01) for intra-abdominal septic complications. For prediction of intra-abdominal septic complications, receiver operating characteristic curve analysis showed that a C-reactive protein cutoff of 14.50 mg/L provided negative and positive predictive values of 96.84% and 34.07%. In addition, the change in C-reactive protein levels over the 2 weeks before surgery was greater in the intra-abdominal septic complications group than the group with no intra-abdominal septic complications (p < 0.01), and the directions of change were opposite, upward in the former and downward in the latter. Apart from being a risk factor for intra-abdominal septic complications (p < 0.01), receiver operating characteristic curve analysis showed that the change in C-reactive protein levels before surgery had a negative predictive value for intra-abdominal septic complications of 98.66% and a positive predictive value of 76.09%. This was a retrospective study. Changes in C-reactive protein before surgical treatment of Crohn's disease could serve as a practical predictive index for postoperative intra-abdominal septic complications.
Rizzo, Giuseppe; Aiello, Elisa; Bosi, Costanza; D'Antonio, Francesco; Arduini, Domenico
2017-08-01
The aim of this study was to ascertain whether combined ultrasound assessment of fetal head circumference (HC) and maternal subpubic angle (SPA) prior to the onset of labor may predict the likelihood of an unplanned operative delivery (UOD) in nulliparous women at term. Prospective cohort study of singleton pregnancies in cephalic presentation. Pregnancies experiencing UOD secondary to fetal distress were excluded. HC was assessed transabdominally and SPA values were obtained from a reconstructed coronal plane on three-dimensional (3D) ultrasound performed translabially at 36-38 weeks of gestation. Maternal characteristics, HC expressed as multiple of median, and SPA were compared according to the mode of delivery. Logistic regression and receiver operating characteristics curve analyses were used to analyze the data. 597 pregnancies were included in the study. Spontaneous vaginal delivery occurred in 70.2% of the cases and UOD was required in 29.8%. There was no difference in pregnancy characteristics and birthweight between women who had a spontaneous vaginal birth compared with UOD. The HC multiple of median was larger (1.00 ± 0.02 vs. 1.03 ± 0.02, p ≤ 0.0001), whereas SPA was narrower in the UOD group (124.02 ± 13.64 vs. 102.61 ± 16.13, p ≤ 0.0001). At logistic regression, SPA (OR 0.91, 95% CI 0.89-0.93), HC multiple of median (OR 1.13, 95% CI 1.09-1.17) and maternal height (OR 0.95, 95% CI 0.92-0.99) were independently associated with UOD. When combined, the diagnostic accuracy of a predictive model integrating HC, SPA and maternal height was highly predictive of UOD with an area under the curve of 0.904 (95% CI 0.88-0.93). Ultrasound assessment of fetal HC and maternal SPA after 36 weeks of gestation can identify a subset of women at higher risk of UOD during labor, for whom early planned delivery might be beneficial. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Den, Robert B., E-mail: Robert.Den@jeffersonhospital.org; Feng, Felix Y.; Showalter, Timothy N.
2014-08-01
Purpose: To test the hypothesis that a genomic classifier (GC) would predict biochemical failure (BF) and distant metastasis (DM) in men receiving radiation therapy (RT) after radical prostatectomy (RP). Methods and Materials: Among patients who underwent post-RP RT, 139 were identified for pT3 or positive margin, who did not receive neoadjuvant hormones and had paraffin-embedded specimens. Ribonucleic acid was extracted from the highest Gleason grade focus and applied to a high-density-oligonucleotide microarray. Receiver operating characteristic, calibration, cumulative incidence, and Cox regression analyses were performed to assess GC performance for predicting BF and DM after post-RP RT in comparison with clinical nomograms.more » Results: The area under the receiver operating characteristic curve of the Stephenson model was 0.70 for both BF and DM, with addition of GC significantly improving area under the receiver operating characteristic curve to 0.78 and 0.80, respectively. Stratified by GC risk groups, 8-year cumulative incidence was 21%, 48%, and 81% for BF (P<.0001) and for DM was 0, 12%, and 17% (P=.032) for low, intermediate, and high GC, respectively. In multivariable analysis, patients with high GC had a hazard ratio of 8.1 and 14.3 for BF and DM. In patients with intermediate or high GC, those irradiated with undetectable prostate-specific antigen (PSA ≤0.2 ng/mL) had median BF survival of >8 years, compared with <4 years for patients with detectable PSA (>0.2 ng/mL) before initiation of RT. At 8 years, the DM cumulative incidence for patients with high GC and RT with undetectable PSA was 3%, compared with 23% with detectable PSA (P=.03). No outcome differences were observed for low GC between the treatment groups. Conclusion: The GC predicted BF and metastasis after post-RP irradiation. Patients with lower GC risk may benefit from delayed RT, as opposed to those with higher GC; however, this needs prospective validation. Genomic-based models may be useful for improved decision-making for treatment of high-risk prostate cancer.« less
Sahin, Hilal; Sarioglu, Fatma Ceren; Bagci, Mustafa; Karadeniz, Tugba; Uluer, Hatice; Sanci, Muzaffer
2018-05-01
The aim of this retrospective single-center study was to evaluate the relationship between maximum tumor size, tumor volume, tumor volume ratio (TVR) based on preoperative magnetic resonance (MR) volumetry, and negative histological prognostic parameters (deep myometrial invasion [MI], lymphovascular space invasion, tumor histological grade, and subtype) in International Federation of Gynecology and Obstetrics stage I endometrial cancer. Preoperative pelvic MR imaging studies of 68 women with surgical-pathologic diagnosis of International Federation of Gynecology and Obstetrics stage I endometrial cancer were reviewed for assessment of MR volumetry and qualitative assessment of MI. Volume of the tumor and uterus was measured with manual tracing of each section on sagittal T2-weighted images. Tumor volume ratio was calculated according to the following formula: TVR = (total tumor volume/total uterine volume) × 100. Receiver operating characteristics curve was performed to investigate a threshold for TVR associated with MI. The Mann-Whitney U test, Kruskal-Wallis test, and linear regression analysis were applied to evaluate possible differences between tumor size, tumor volume, TVR, and negative prognostic parameters. Receiver operating characteristics curve analysis of TVR for prediction of deep MI was statistically significant (P = 0.013). An optimal TVR threshold of 7.3% predicted deep myometrial invasion with 85.7% sensitivity, 46.8% specificity, 41.9% positive predictive value, and 88.0% negative predictive value. Receiver operating characteristics curve analyses of TVR, tumor size, and tumor volume for prediction of tumor histological grade or lymphovascular space invasion were not significant. The concordance between radiologic and pathologic assessment for MI was almost excellent (κ value, 0.799; P < 0.001). Addition of TVR to standard radiologic assessment of deep MI increased the sensitivity from 90.5% to 95.2%. Tumor volume ratio, based on preoperative MR volumetry, seems to predict deep MI independently in stage I endometrial cancer with insufficient sensitivity and specificity. Its value in clinical practice for risk stratification models in endometrial cancer has to be studied in larger cohort of patients.
Applying U.S. EOP Analytical Justification Experience for VVER Plants in the Ukraine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Linn, Paul A.; Julian, Harold V.; Chapman, James R.
2002-07-01
The foundation for new Emergency Operating Instructions (EOIs) being developed at several plants in the Ukraine is the Westinghouse Owners Group (WOG) Emergency Response Guidelines (ERGs) developed in the U.S. The ERGs were chosen as a base for the new EOIs for several reasons. First the overall structure and format was adaptable to VVER Pressurized Water Reactor (PWR) designs. Second, the ERGs have served as a base for many plant EOIs in both the U.S. and internationally. Third, key information supporting the ERGs was available. This paper describes the method used at one of the Ukrainian plants to provide anmore » analytical justification for their EOIs. The method being employed by a second plant is very similar, differing only slightly in how it is implemented. The WOG ERG development program, which started shortly after the accident at Three Mile Island Unit 2, used many sources of technical information on plant and system transient response, which were available in support of the plant design and licensing efforts. In addition, operating experience from many operating PWR plants in the U.S. and around the world was used. For example, design basis accident (DBA) analyses, documented in a plant's Safety Analysis Report (SAR) and other design documents, had been performed by Nuclear Steam Supply System (NSSS) vendors, utilities, or the Architect/Engineer. All relevant sources were considered in the development of the ERGs. Limited Probabilistic Risk Assessment (PRA) analyses were available during that time period. When a technical basis for a recovery strategy and associated operator actions was not available, an analysis was defined and performed. In general, these analyses were performed on a generic basis, and addressed the different categories of design (e.g., number of reactor coolant loops and/or low/high pressure safety injection system design). U.S. Nuclear Power plants that were in the WOG program were responsible for implementing the generic ERGs. This required the utilities to review the generic analyses to ensure that they were applicable and to justify any deviations from the ERG methodology. Modern PRA analyses are similar to the analyses supporting the ERGs since they address multiple failures and assume better estimate or expected assumptions for equipment availability and operator performance. The process being employed by Ukrainian plants is similar to the WOG. That is, available analyses and operating experience are being reviewed and pertinent information extracted to assist in the analytical justification of the EOIs. This includes the use of recently updated PRA and DBA analyses, other 'original' design information and operating experience. A systematic review of the EOIs is being conducted to identify items requiring analytical justification. For each analysis identified, the specific purpose of the analysis is being documented. The analysis needs are then compared to the available analyses and operating experience. From this review, new analyses needed to justify the EOIs are developed, and a basis for using existing analyses is established. The work is being conducted in two phases. The first phase performs all of the reviews and assessments necessary to determine the new analyses required to justify the EOIs. In the second phase, these new analyses will be conducted and documented, and the EOI Analytical Justification (AJ) report will be written. (authors)« less
Some Operating Experience and Problems Encountered During Operation of a Free-jet Facility
NASA Technical Reports Server (NTRS)
Mcaulay, John E; Prince, William R
1957-01-01
During a free-jet investigation of a 28-inch ram-jet engine at a Mach number of 2.35, flow pulsation at the engine inlet were discovered which proved to have an effect on the engine performance and operational characteristics, particularly the engine rich blowout limits. This report discusses the finding of the flow pulsations, their elimination, and effect. Other facility characteristics, such as the establishment of flow simulation and the degree of subcritical operation of the diffuser, are also explained.
NASA Astrophysics Data System (ADS)
Lee, Sang-Kwon
This thesis is concerned with the development of a useful engineering technique to detect and analyse faults in rotating machinery. The methods developed are based on the advanced signal processing such as the adaptive signal processing and higher-order time frequency methods. The two-stage Adaptive Line Enhancer (ALE), using adaptive signal processing, has been developed for increasing the Signal to Noise Ratio of impulsive signals. The enhanced signal can then be analysed using time frequency methods to identify fault characteristics. However, if after pre-processing by the two stage ALE, the SNR of the signals is low, the residual noise often hinders clear identification of the fault characteristics in the time-frequency domain. In such cases, higher order time-frequency methods have been proposed and studied. As examples of rotating machinery, the internal combustion engine and an industrial gear box are considered in this thesis. The noise signal from an internal combustion engine and vibration signal measured on a gear box are studied in detail. Typically an impulsive signal manifests itself when the fault occurs in the machinery and is embedded in background noise, such as the fundamental frequency and its harmonic orders of the rotation speed and broadband noise. The two-stage ALE is developed for reducing this background noise. Conditions for the choice of adaptive filter parameters are studied and suitable adaptive algorithms given. The enhanced impulsive signal is analysed in the time- frequency domain using the Wigner higher order moment spectra (WHOMS) and the multi-time WHOMS (which is a dual form of the WHOMS). The WHOMS suffers from unwanted cross-terms, which increase dramatically as the order increases. Novel expressions for the cross-terms in WHOMS have been presented. The number of cross-terms can be reduced by taking the principal slice of the WHOMS. The residual cross-terms are smoothed by using a general class of kernel functions and the γ-method kernel function which is a novel development in this thesis. The WVD and the sliced WHOMS for synthesised signals and measured data from rotating machinery are analysed. The estimated ROC (Receive Operating Characteristic) curves for these methods are computed. These results lead to the conclusion that the detection performance when using the sliced WHOMS, for impulsive signals in embedded in broadband noise, is better than that of the Wigner-Ville distribution. Real data from a faulty car engine and faulty industrial gears are analysed. The car engine radiates an impulsive noise signal due to the loosening of a spark plug. The faulty industrial gear produces an impulsive vibration signal due to a spall on the tooth face in gear. The two- stage ALE and WHOMS are successfully applied to detection and analysis of these impulsive signals.
14 CFR 33.65 - Surge and stall characteristics.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 33.65 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.65 Surge and stall characteristics. When the engine is operated in accordance with operating instructions required by...
14 CFR 33.65 - Surge and stall characteristics.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Section 33.65 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.65 Surge and stall characteristics. When the engine is operated in accordance with operating instructions required by...
Day-night variation in operationally retrieved TOVS temperature biases
NASA Technical Reports Server (NTRS)
Kidder, Stanley Q.; Achtemeier, Gary L.
1986-01-01
Several authors have reported that operationally retrieved TOVS (TIROS Operational Vertical Sounder) temperatures are biased with respect to rawinsonde temperatures or temperature analyses. This note reports a case study from which it is concluded that, at least for the time period Mar. 26 through Apr. 8, 1979, there was a significant day-night variation in TOVS mean layer virtual temperature biases with respect to objective analyses of rawinsonde data over the U.S.
1981-02-01
7. Reseaarch Product 81-26 - DESIGN GUIDELINES AND CRITERIA FOR USER/ I;. I’OPERATOR TRANSACTIONS WITH BATTLEFIELD AUTOMIATED SYSTEMS I’ /HVtAN...FACTORS XWLYSES :’F K~R/ OPERATOR TRANSACTIONS WTHT TACFIRE - THE TACTICAL FIRE DiRECTION SY2T3EM A HUMAN FACTORS TECHNICAL AREA L~h~h K L-J 1’ U~~i~ ll...Battlefield Auto- Inter : Oct 1979-Feb 1981 mated Systems Volume III-A: Human Factors 4t C/ Analyses of User/Operator Transactions with 6. PERFORMING
Subjective scaling of mental workload in a multi-task environment
NASA Technical Reports Server (NTRS)
Daryanian, B.
1982-01-01
Those factors in a multi-task environment that contribute to the operators' "sense" of mental workload were identified. The subjective judgment as conscious experience of mental effort was decided to be the appropriate method of measurement. Thurstone's law of comparative judgment was employed in order to construct interval scales of subjective mental workload from paired comparisons data. An experimental paradigm (Simulated Multi-Task Decision-Making Environment) was employed to represent the ideal experimentally controlled environment in which human operators were asked to "attend" to different cases of Tulga's decision making tasks. Through various statistical analyses it was found that, in general, a lower number of tasks-to-be-processed per unit time (a condition associated with longer interarrival times), results in a lower mental workload, a higher consistency of judgments within a subject, a higher degree of agreement among the subjects, and larger distances between the cases on the Thurstone scale of subjective mental workload. The effects of various control variables and their interactions, and the different characteristics of the subjects on the variation of subjective mental workload are demonstrated.
An Object-Independent ENZ Metamaterial-Based Wideband Electromagnetic Cloak
Islam, Sikder Sunbeam; Faruque, Mohammad Rashed Iqbal; Islam, Mohammad Tariqul
2016-01-01
A new, metamaterial-based electromagnetic cloaking operation is proposed in this study. The metamaterial exhibits a sharp transmittance in the C-band of the microwave spectrum with negative effective property of permittivity at that frequency. Two metal arms were placed on an FR-4 substrate to construct a double-split-square shape structure. The size of the resonator was maintained to achieve the effective medium property of the metamaterial. Full wave numerical simulation was performed to extract the reflection and transmission coefficients for the unit cell. Later on, a single layer square-shaped cloak was designed using the proposed metamaterial unit cell. The cloak hides a metal cylinder electromagnetically, where the material exhibits epsilon-near-zero (ENZ) property. Cloaking operation was demonstrated adopting the scattering-reduction technique. The measured result was provided to validate the characteristics of the metamaterial and the cloak. Some object size- and shape-based analyses were performed with the cloak, and a common cloaking region was revealed over more than 900 MHz in the C-band for the different objects. PMID:27634456
NASA Technical Reports Server (NTRS)
Rochelle, W. C.; Liu, D. K.; Nunnery, W. J., Jr.; Brandli, A. E.
1975-01-01
This paper describes the application of the SINDA (systems improved numerical differencing analyzer) computer program to simulate the operation of the NASA/JSC MIUS integration and subsystems test (MIST) laboratory. The MIST laboratory is designed to test the integration capability of the following subsystems of a modular integrated utility system (MIUS): (1) electric power generation, (2) space heating and cooling, (3) solid waste disposal, (4) potable water supply, and (5) waste water treatment. The SINDA/MIST computer model is designed to simulate the response of these subsystems to externally impressed loads. The computer model determines the amount of recovered waste heat from the prime mover exhaust, water jacket and oil/aftercooler and from the incinerator. This recovered waste heat is used in the model to heat potable water, for space heating, absorption air conditioning, waste water sterilization, and to provide for thermal storage. The details of the thermal and fluid simulation of MIST including the system configuration, modes of operation modeled, SINDA model characteristics and the results of several analyses are described.
Klotzbücher, Sascha; Lässig, Peter; Jiangmei, Qin; Weigelin-Schwiedrzik, Susanne
2011-01-01
In 2002, the Chinese leadership announced a change in national welfare policy: Voluntary medical schemes at county level, called the “New Rural Co-operative Medical System” should cover all counties by 2010. This article addresses the main characteristics of this system, analyses the introduction of local schemes based on our own field studies in one Kazak county of the Xinjiang Uyghur Autonomous Region since 2006, and argues that the fast progressing of the local scheme and the flexibility shown by local administrators in considering structural and procedural adjustments are not the result of central directives but of local initiatives. Recentralization from the township governments to functional departments in the provincial and the central state administration is only one aspect of current rural governance. Complementary forms of locally embedded responsiveness to the needs of health care recipients are crucial in restructuring the administration and discharge of health care. These new modes of governance are different from the hierarchical control and institutionalized representation of interests of the local population. PMID:22058584
An Object-Independent ENZ Metamaterial-Based Wideband Electromagnetic Cloak.
Islam, Sikder Sunbeam; Faruque, Mohammad Rashed Iqbal; Islam, Mohammad Tariqul
2016-09-16
A new, metamaterial-based electromagnetic cloaking operation is proposed in this study. The metamaterial exhibits a sharp transmittance in the C-band of the microwave spectrum with negative effective property of permittivity at that frequency. Two metal arms were placed on an FR-4 substrate to construct a double-split-square shape structure. The size of the resonator was maintained to achieve the effective medium property of the metamaterial. Full wave numerical simulation was performed to extract the reflection and transmission coefficients for the unit cell. Later on, a single layer square-shaped cloak was designed using the proposed metamaterial unit cell. The cloak hides a metal cylinder electromagnetically, where the material exhibits epsilon-near-zero (ENZ) property. Cloaking operation was demonstrated adopting the scattering-reduction technique. The measured result was provided to validate the characteristics of the metamaterial and the cloak. Some object size- and shape-based analyses were performed with the cloak, and a common cloaking region was revealed over more than 900 MHz in the C-band for the different objects.
NASA Astrophysics Data System (ADS)
Truhanov, V. N.; Sultanov, M. M.
2017-11-01
In the present article researches of statistical material on the refusals and malfunctions influencing operability of heat power installations have been conducted. In this article the mathematical model of change of output characteristics of the turbine depending on number of the refusals revealed in use has been presented. The mathematical model is based on methods of mathematical statistics, probability theory and methods of matrix calculation. The novelty of this model is that it allows to predict the change of the output characteristic in time, and the operating influences have been presented in an explicit form. As desirable dynamics of change of the output characteristic (function, reliability) the law of distribution of Veybull which is universal is adopted since at various values of parameters it turns into other types of distributions (for example, exponential, normal, etc.) It should be noted that the choice of the desirable law of management allows to determine the necessary management parameters with use of the saved-up change of the output characteristic in general. The output characteristic can be changed both on the speed of change of management parameters, and on acceleration of change of management parameters. In this article the technique of an assessment of the pseudo-return matrix has been stated in detail by the method of the smallest squares and the standard Microsoft Excel functions. Also the technique of finding of the operating effects when finding restrictions both for the output characteristic, and on management parameters has been considered. In the article the order and the sequence of finding of management parameters has been stated. A concrete example of finding of the operating effects in the course of long-term operation of turbines has been shown.
Optimizations on supply and distribution of dissolved oxygen in constructed wetlands: A review.
Liu, Huaqing; Hu, Zhen; Zhang, Jian; Ngo, Huu Hao; Guo, Wenshan; Liang, Shuang; Fan, Jinlin; Lu, Shaoyong; Wu, Haiming
2016-08-01
Dissolved oxygen (DO) is one of the most important factors that can influence pollutants removal in constructed wetlands (CWs). However, problems of insufficient oxygen supply and inappropriate oxygen distribution commonly exist in traditional CWs. Detailed analyses of DO supply and distribution characteristics in different types of CWs were introduced. It can be concluded that atmospheric reaeration (AR) served as the promising point on oxygen intensification. The paper summarized possible optimizations of DO in CWs to improve its decontamination performance. Process (tidal flow, drop aeration, artificial aeration, hybrid systems) and parameter (plant, substrate and operating) optimizations are particularly discussed in detail. Since economic and technical defects are still being cited in current studies, future prospects of oxygen research in CWs terminate this review. Copyright © 2016. Published by Elsevier Ltd.
Alternative Geothermal Power Production Scenarios
Sullivan, John
2014-03-14
The information given in this file pertains to Argonne LCAs of the plant cycle stage for a set of ten new geothermal scenario pairs, each comprised of a reference and improved case. These analyses were conducted to compare environmental performances among the scenarios and cases. The types of plants evaluated are hydrothermal binary and flash and Enhanced Geothermal Systems (EGS) binary and flash plants. Each scenario pair was developed by the LCOE group using GETEM as a way to identify plant operational and resource combinations that could reduce geothermal power plant LCOE values. Based on the specified plant and well field characteristics (plant type, capacity, capacity factor and lifetime, and well numbers and depths) for each case of each pair, Argonne generated a corresponding set of material to power ratios (MPRs) and greenhouse gas and fossil energy ratios.
Color and Grey Scale in Sonar Displays
NASA Technical Reports Server (NTRS)
Kraiss, K. F.; Kuettelwesch, K. H.
1984-01-01
In spite of numerous publications 1 it is still rather unclear, whether color is of any help in sonar displays. The work presented here deals with a particular type of sonar data, i.e., LOFAR-grams (low frequency analysing and recording) where acoustic sensor data are continuously written as a time-frequency plot. The question to be answered quantitatively is, whether color coding does improve target detection when compared with a grey scale code. The data show significant differences in receiver-operating characteristics performance for the selected codes. In addition it turned out, that the background noise level affects the performance dramatically for some color codes, while others remain stable or even improve. Generally valid rules are presented on how to generate useful color scales for this particular application.
An Overview of the HST Advanced Camera for Surveys' On-orbit Performance
NASA Astrophysics Data System (ADS)
Hartig, G. F.; Ford, H. C.; Illingworth, G. D.; Clampin, M.; Bohlin, R. C.; Cox, C.; Krist, J.; Sparks, W. B.; De Marchi, G.; Martel, A. R.; McCann, W. J.; Meurer, G. R.; Sirianni, M.; Tsvetanov, Z.; Bartko, F.; Lindler, D. J.
2002-05-01
The Advanced Camera for Surveys (ACS) was installed in the HST on 7 March 2002 during the fourth servicing mission to the observatory, and is now beginning science operations. The ACS provides HST observers with a considerably more sensitive, higher-resolution camera with wider field and polarimetric, coronagraphic, low-resolution spectrographic and solar-blind FUV capabilities. We review selected results of the early verification and calibration program, comparing the achieved performance with the advertised specifications. Emphasis is placed on the optical characteristics of the camera, including image quality, throughput, geometric distortion and stray-light performance. More detailed analyses of various aspects of the ACS performance are presented in other papers at this meeting. This work was supported by a NASA contract and a NASA grant.
Blackmon, Jaime E; Liptak, Cori; Recklitis, Christopher J
2017-03-01
Three previously developed short forms of the Beck Depression Inventory-Youth (BDI-Y) were validated against the standard 20-item BDI-Y; 168 adolescent survivors completed the standard and short-form versions of the BDI-Y. The short forms were evaluated for internal consistency and compared with the standard BDI-Y using correlation coefficients and receiver operating characteristic curve analyses. The three short forms had good internal consistency (α > 0.85), high correlations with the total BDI-Y scale (r > 0.85), and good discrimination compared with the standard BDI-Y cutoff score (area under the ROC curve >0.95). Consistent with prior findings, strong psychometric properties of an eight-item short form support its use as a screening measure for adolescent cancer survivors.
Using Ontology Fingerprints to disambiguate gene name entities in the biomedical literature
Chen, Guocai; Zhao, Jieyi; Cohen, Trevor; Tao, Cui; Sun, Jingchun; Xu, Hua; Bernstam, Elmer V.; Lawson, Andrew; Zeng, Jia; Johnson, Amber M.; Holla, Vijaykumar; Bailey, Ann M.; Lara-Guerra, Humberto; Litzenburger, Beate; Meric-Bernstam, Funda; Jim Zheng, W.
2015-01-01
Ambiguous gene names in the biomedical literature are a barrier to accurate information extraction. To overcome this hurdle, we generated Ontology Fingerprints for selected genes that are relevant for personalized cancer therapy. These Ontology Fingerprints were used to evaluate the association between genes and biomedical literature to disambiguate gene names. We obtained 93.6% precision for the test gene set and 80.4% for the area under a receiver-operating characteristics curve for gene and article association. The core algorithm was implemented using a graphics processing unit-based MapReduce framework to handle big data and to improve performance. We conclude that Ontology Fingerprints can help disambiguate gene names mentioned in text and analyse the association between genes and articles. Database URL: http://www.ontologyfingerprint.org PMID:25858285
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neubauer, J.; Wood, E.
2013-01-01
Hybrid electric vehicles, plug-in hybrid electric vehicles, and battery electric vehicles offer the potential to reduce both oil imports and greenhouse gases, as well as to offer a financial benefit to the driver. However, assessing these potential benefits is complicated by several factors, including the driving habits of the operator. We focus on driver aggression, i.e., the level of acceleration and velocity characteristic of travel, to (1) assess its variation within large, real-world drive datasets, (2) quantify its effect on both vehicle efficiency and economics for multiple vehicle types, (3) compare these results to those of standard drive cycles commonlymore » used in the industry, and (4) create a representative drive cycle for future analyses where standard drive cycles are lacking.« less
Xiao, Xia; Hu, Haoliang; Xu, Yan; Lei, Min; Xiong, Qianzhu
2016-08-16
Optical voltage transformers (OVTs) have been applied in power systems. When performing accuracy performance tests of OVTs large differences exist between the electromagnetic environment and the temperature variation in the laboratory and on-site. Therefore, OVTs may display different error characteristics under different conditions. In this paper, OVT prototypes with typical structures were selected to be tested for the error characteristics with the same testing equipment and testing method. The basic accuracy, the additional error caused by temperature and the adjacent phase in the laboratory, the accuracy in the field off-line, and the real-time monitoring error during on-line operation were tested. The error characteristics under the three conditions-laboratory, in the field off-line and during on-site operation-were compared and analyzed. The results showed that the effect of the transportation process, electromagnetic environment and the adjacent phase on the accuracy of OVTs could be ignored for level 0.2, but the error characteristics of OVTs are dependent on the environmental temperature and are sensitive to the temperature gradient. The temperature characteristics during on-line operation were significantly superior to those observed in the laboratory.
Motmans, Joz; Ponnet, Koen; De Cuypere, Griet
2015-07-01
By performing secondary data analyses of existing medical, social, and state data, this study examined the sociodemographic profile of trans persons in Belgium and gains knowledge on those who are functionally invisible in traditional epidemiological studies or clinical samples. Based on medical interventions, post-operative transsexual persons were selected from a social survey data set, to compare their sociodemographic profile with available data on legal sex changes from the Belgian National Register and with published data on clinical samples of post-operative transsexual persons. Furthermore, based on self-chosen gender identity categories in the social survey data, transsexual participants were compared with the transgender participants (those people feeling neither female nor male, or both female and male, or otherwise). The sociodemographic data on the post-operative transsexual persons from the three datasets appeared to be very similar. Based on identity categories, the data on transsexual and transgender persons from the social survey showed differences in marital status and employment. Transsexual persons were significantly more often divorced than transgender persons. Both groups differed significantly in employment status. Information about transgender people (or the "in-between" group) is too often lacking from studies but can be obtained when identity instead of medical criteria are used in research.
A simple capacitive method to evaluate ethanol fuel samples
NASA Astrophysics Data System (ADS)
Vello, Tatiana P.; de Oliveira, Rafael F.; Silva, Gustavo O.; de Camargo, Davi H. S.; Bufon, Carlos C. B.
2017-02-01
Ethanol is a biofuel used worldwide. However, the presence of excessive water either during the distillation process or by fraudulent adulteration is a major concern in the use of ethanol fuel. High water levels may cause engine malfunction, in addition to being considered illegal. Here, we describe the development of a simple, fast and accurate platform based on nanostructured sensors to evaluate ethanol samples. The device fabrication is facile, based on standard microfabrication and thin-film deposition methods. The sensor operation relies on capacitance measurements employing a parallel plate capacitor containing a conformational aluminum oxide (Al2O3) thin layer (15 nm). The sensor operates over the full range water concentration, i.e., from approximately 0% to 100% vol. of water in ethanol, with water traces being detectable down to 0.5% vol. These characteristics make the proposed device unique with respect to other platforms. Finally, the good agreement between the sensor response and analyses performed by gas chromatography of ethanol biofuel endorses the accuracy of the proposed method. Due to the full operation range, the reported sensor has the technological potential for use as a point-of-care analytical tool at gas stations or in the chemical, pharmaceutical, and beverage industries, to mention a few.
Numerical investigation and experimental development on VM-PT cryocooler operating below 4 K
NASA Astrophysics Data System (ADS)
Zhang, Tong; Pan, Changzhao; Zhou, Yuan; Wang, Junjie
2016-12-01
Vuilleumier coupling pulse tube (VM-PT) cryocooler is a novel kind of cryocooler capable of attaining liquid helium temperature which had been experimentally verified. Depending on different coupling modes and phase shifters, VM-PT cryocooler can be designed in several configurations. This paper presents a numerical investigation on three typical types of VM-PT cryocoolers, which are gas-coupling mode with room temperature phase shifter (GCRP), gas-coupling mode with cold phase shifter (GCCP) and thermal-coupling mode with cold phase shifter (TCCP). Firstly, three configurations are optimized on operating parameters to attain lower no-load temperature. Then, based on the simulation results, distributions of acoustic power, enthalpy flow, pressure wave, and volume flow rate are presented and discussed to better understand the energy flow characteristics and coupling mechanism. Meanwhile, analyses of phase relationship and exergy loss are also performed. Furthermore, a GCCP experimental system with optimal comprehensive performance among three configurations was built and tested. Experimental results showed good consistency with the simulations. Finally, a no-load temperature of 3.39 K and cooling power of 9.75 mW at 4.2 K were obtained with a pressure ratio of 1.7, operating frequency of 1.22 Hz and mean pressure of 1.5 MPa.
[The perception of risk among police officers from different areas of the State of Rio de Janeiro].
Constantino, Patrícia; Ribeiro, Adalgisa Peixoto; Correia, Bruna Soares Chaves
2013-03-01
This article seeks to identify the perception of risk among police officers in the State of Rio de Janeiro based on their areas of operation: Capital, Interior and Baixada Fluminense (BF), by analyzing comparative victimization. It is a transversal study using the triangulation method. The quantitative research investigated 533 police officers in the Capital, 159 in the Interior and 222 in the BF; the qualitative approach included interviews with 17 police chiefs and 15 focus groups in the three areas. The results indicate that risk perceptions of officers, and the strategies used to minimize them are characteristics that unite them. Despite its universal nature, risk has differentiated gradations in relation to function and territory of operation. In the Capital there is greater exposure to the risk of confrontation with criminals, less respect for the police from the population, though there is greater operational support from the corporation. Contrary to perception, victimization is related to the territory: 67.8% of police officers were victimized in the Capital last year; 13.7% in the Interior; and 9.7% in the BF. The expectation is that the analyses will provide input for management of technical support and health assistance for police officers, considering the specificities of work in the different areas.
Domínguez-Vega, Gerardo; Pera, Manuel; Ramón, José M; Puig, Sonia; Membrilla, Estela; Sancho, Joan; Grande, Luis
2013-01-01
To analyse the outcomes of laparoscopic versus open repair for perforated peptic ulcers (PPU). All patients undergoing PPU repair between January 2002 and March 2012 were included in the study. Demographic characteristics, operation time, complications, and length of hospital stay were evaluated. Two hundred and twelve patients (median age, 49 years) were included, 60 in the laparoscopic group and 52 in the open group. Patients operated laparoscopically were significantly younger and had a higher consumption of tobacco, alcohol and cannabis. Median acute symptoms time was shorter in the laparoscopic group (6h) compared to the open group (12h; P=.025) Symptoms time was shorter in the laparoscopic group. Median operating time was significantly longer in the laparoscopic group (104.5min vs. 76min, P=.025). The percentage of conversion to open repair was 25%. There was no difference in morbidity between 2 groups, but there were 3 deaths in the open group. Median hospital stay was significantly shorter in patients treated laparoscopically when compared with the open group (6 days vs. 8 days; P=.041). Laparoscopic and open repair are equally safe in the management of PPU. A shorter hospital stay can be achieved in the laparoscopic group. Copyright © 2012 AEC. Published by Elsevier Espana. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakhamkin, M.; Swensen, E.C.; Abitante, P.A.
1990-10-01
A study was performed to evaluate the performance and cost characteristics of two alternative CAES-plant concepts which utilize the low-pressure expander's exhaust-gas heat for the generation of steam in a heat recovery steam generator (HRSG). Both concepts result in increased net-power generation relative to a conventional CAES plant with a recuperator. The HRSG-generated steam produces additional power in either a separate steam-turbine bottoming cycle (CAESCC) or by direct injection into and expansion through the CAES-turboexpander train (CAESSI). The HRSG, which is a proven component of combined-cycle and cogeneration plants, replaces the recuperator of a conventional CAES plant, which has demonstratedmore » the potential for engineering and operating related problems and higher costs than were originally estimated. To enhance the credibility of the results, the analyses performed were based on the performance, operational and cost data of the 110-MW CAES plant currently under construction for the Alabama Electric Cooperative (AEC). The results indicate that CAESCC- and CAESSI-plant concepts are attractive alternatives to the conventional CAES plant with recuperator, providing greater power generation, up to 44-MW relative to the AEC CAES plant, with competitive operating and capital costs. 5 refs., 43 figs., 26 tabs.« less
Recurrent glioblastoma: Current patterns of care in an Australian population.
Parakh, Sagun; Thursfield, Vicky; Cher, Lawrence; Dally, Michael; Drummond, Katharine; Murphy, Michael; Rosenthal, Mark A; Gan, Hui K
2016-02-01
This retrospective population-based survey examined current patterns of care for patients with recurrent glioblastoma (rGBM) who had previously undergone surgery and post-operative therapy at original diagnosis. The patients were identified from the Victorian Cancer Registry (VCR) from 2006 to 2008. Patient demographics, tumour characteristics and oncological management were extracted using a standardised survey by the treating clinicians/VCR staff and results analysed by the VCR. Kaplan-Meier estimates of overall survival (OS) at diagnosis and progression were calculated. A total of 95 patients (48%) received treatment for first recurrence; craniotomy and post-operative treatment (38), craniotomy only (34) and non-surgical treatment (23). Patients receiving treatment at first progression had a higher median OS than those who did not (7 versus 3 months, p<0.0001). All patients progressed after treatment for first progression with 43 patients (45%) receiving treatment at second progression. To our knowledge this is the first population-based pattern of care survey of treatment for rGBM in an era where post-operative "Stupp" chemo-radiation is standard. First and second line therapy for rGBM is common and associated with significant benefit. Treatment generally includes re-resection and/or systemic therapy. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOT National Transportation Integrated Search
1996-01-01
The purpose of this study was to evaluate and compare the safety and operational characteristics of the single point urban interchange (SPUI) and the diamond interchange (DI) and develop guidelines that identify traffic and/or geometric conditions th...