30 CFR 90.205 - Approved sampling devices; operation; air flowrate.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...
[Microbial air monitoring in operating theatre: active and passive samplings].
Pasquarella, C; Masia, M D; Nnanga, Nga; Sansebastiano, G E; Savino, A; Signorelli, C; Veronesi, L
2004-01-01
Microbial air contamination was evaluated in 11 operating theatres using active and passive samplings. SAS (Surface Air System) air sampling was used to evaluate cfu/m3 and settle plates were used to measure the index of microbial air contamination (IMA). Samplings were performed at the same time on three different days, at three different times (before, during and after the surgical activity). Two points were monitored (patient area and perimeter of the operating theatre). Moreover, the cfu/m3 were evaluated at the air inlet of the conditioner system. 74.7% of samplings performed at the air inlet and 66.7% of the samplings performed at the patient area before the beginning of the surgical activity (at rest) exceeded the 35 cfu/m3 used as threshold value. 100% of IMA values exceeded the threshold value of 5. Using both active and passive sampling, the microbial contamination was shown to increase significantly during activity. The cfu values were higher at the patient area than at the perimeter of the operating theatre. Mean values of the cfu/m3 during activity at the patient area ranged from a minimum of 61+/-41 cfu/m3 to a maximum of 242+/-136 cfu/m3; IMA values ranged from a minimum of 19+/-10 to a maximum of 129+/-60. 15.2% of samplings performed at the patient area using SAS and 75.8% of samplings performed using settle plates exceeded the threshold values of 180 cfu/m3 and 25 respectively, with a significant difference of the percentages. The highest values were found in the operating theatre with inadequate structural and managerial conditions. These findings confirm that the microbiological quality of air may be considered a mirror of the hygienic conditions of the operating theatre. Settle plates proved to be more sensitive in detecting the increase of microbial air contamination related to conditions that could compromise the quality of the air in operating theatres.
Mercury Vacuum Cleaner, Operational Test and Evaluation
1981-03-01
Indirect readings were obtained by air sampling with hopcalite tubes and subsequent analysis by the USAF OEHL Analytical Services Division. - r...during the operational and storage modes of the MRS-3 vacuum. During the operational mode, indirect ( hopcalite ) air sampling was periodically taken at...from the top and bottom sides of the HEPA and charcoal filter. During the storage mode, indirect ( hopcalite and dosimeter coil) air sampling was
Maskrey, Joshua R; Insley, Allison L; Hynds, Erin S; Panko, Julie M
2016-07-01
A 3-month air monitoring study was conducted in Washington County, Pennsylvania, at the request of local community members regarding the potential risks resulting from air emissions of pollutants related to hydraulic fracturing operations. Continuous air monitoring for total volatile organic compounds was performed at two sampling sites, including a school and a residence, located within 900 m of a hydraulic fracturing well pad that had been drilled prior to the study. Intermittent 24-hour air samples for 62 individual volatile organic compounds were also collected. The ambient air at both sites was monitored during four distinct periods of unconventional natural gas extraction activity: an inactive period prior to fracturing operations, during fracturing operations, during flaring operations, and during another inactive period after operations. The results of the continuous monitoring during fracturing and flaring sampling periods for total volatile organic compounds were similar to the results obtained during inactive periods. Total volatile organic compound 24-hour average concentrations ranged between 0.16 and 80 ppb during all sampling periods. Several individual volatile compounds were detected in the 24-hour samples, but they were consistent with background atmospheric levels measured previously at nearby sampling sites and in other areas in Washington County. Furthermore, a basic yet conservative screening level evaluation demonstrated that the detected volatile organic compounds were well below health-protective levels. The primary finding of this study was that the operation of a hydraulic fracturing well pad in Washington County did not substantially affect local air concentrations of total and individual volatile organic compounds.
Napoli, Christian; Marcotrigiano, Vincenzo; Montagna, Maria Teresa
2012-08-02
Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.
An automated atmospheric sampling system operating on 747 airliners
NASA Technical Reports Server (NTRS)
Perkins, P. J.; Gustafsson, U. R. C.
1976-01-01
An air sampling system that automatically measures the temporal and spatial distribution of particulate and gaseous constituents of the atmosphere is collecting data on commercial air routes covering the world. Measurements are made in the upper troposphere and lower stratosphere (6 to 12 km) of constituents related to aircraft engine emissions and other pollutants. Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This unique system includes specialized instrumentation, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituent and related flight data are tape recorded in flight for later computer processing on the ground.
Legionnaires' Disease Bacteria in power plant cooling systems: downtime report. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.
1985-04-01
Legionnaires' Disease Bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Groups A, B, and C Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 126 air samples collected. These were predominantly Group A Legionella (L. pneumophila, serogroups 1 to 6). All 12 positive samples had been collected in the vicinity of water boxes, condensers, detention ponds, and cooling towers during downtime operations where aerosolization of Legionella populations would be expected. None of the air samples yielded infectious Legionella when injected into guinea pigs. Detection of Legionella in air samples taken during downtime was significantly more likely than detection during normal operating conditions (p <0.01). 13 refs., 4 figs., 10 tabs.« less
2012-01-01
Background Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. Methods The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). Results The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. Conclusion It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information. PMID:22853006
An automated atmospheric sampling system operating on 747 airliners
NASA Technical Reports Server (NTRS)
Perkins, P.; Gustafsson, U. R. C.
1975-01-01
An air sampling system that automatically measures the temporal and spatial distribution of selected particulate and gaseous constituents of the atmosphere has been installed on a number of commercial airliners and is collecting data on commercial air routes covering the world. Measurements of constituents related to aircraft engine emissions and other pollutants are made in the upper troposphere and lower stratosphere (6 to 12 km) in support of the Global Air Sampling Program (GASP). Aircraft operated by different airlines sample air at latitudes from the Arctic to Australia. This system includes specialized instrumentation for measuring carbon monoxide, ozone, water vapor, and particulates, a special air inlet probe for sampling outside air, a computerized automatic control, and a data acquisition system. Air constituents and related flight data are tape recorded in flight for later computer processing on the ground.
Air-conditioning vs. presence of pathogenic fungi in hospital operating theatre environment.
Gniadek, Agnieszka; Macura, Anna B
2011-01-01
Infections related to modern surgical procedures present a difficult problem for contemporary medicine. Infections acquired during surgery represent a risk factor related to therapeutical interventions. Eradication of microorganisms from hospital operating theatre environment may contribute to reduction of infections as the laminar flow air-conditioning considerably reduces the number of microorganisms in the hospital environment. The objective of the study was to evaluate the occurrence of fungi in air-conditioned operating theatre rooms. The study was carried out in one of the hospitals in Krak6w during December 2009. Indoor air samples and imprints from the walls were collected from five operating theatre rooms. A total of fifty indoor air samples were collected with a MAS-100 device, and twenty five imprints from the walls were collected using a Count Tact method. Fungal growth was observed in 48 air samples; the average numbers of fungi were within the range of 5-100 c.f.u. in one cubic metre of the air. Fungi were detected only in four samples of the wall imprints; the number of fungi was 0.01 c.f.u. per one square centimetre of the surface. The mould genus Aspergillus was most frequently isolated, and the species A. fumigatus and A. versicolor were the dominating ones. To ensure microbiological cleanness of hospital operating theatre, the air-conditioning system should be properly maintained. Domination of the Aspergillus fungi in indoor air as well as increase in the number of moulds in the samples taken in evenings (p < 0.05) may suggest that the room decontamination procedures were neglected.
Legionnaires' disease bacteria in power plant cooling systems: downtime report. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tyndall, R.L.; Solomon, J.A.; Christensen, S.W.
1985-11-01
Legionnaires' disease bacteria (Legionella) are a normal part of the aquatic community that, when aerosolized, can be pathogenic to man. The downtime study was designed to determine the degree to which Legionella populations are aerosolized during cleaning and maintenance operations in a closed-cycle steam-electric power plant. Both high-volume and impinger air samples were collected prior to and during downtime operations. Emphasis was placed on sampling inside or adjacent to water boxes, condensers, and cooling towers. Control air samples were taken upwind from the plant site. Water and sludge samples were also collected at various locations. In the laboratory, the concentrationsmore » of Legionella were determined using the direct fluorescent antibody method. All positive air samples, and other selected air samples, were injected into guinea pigs to detect infectious Legionella. Legionella could be detected in only 12 of the 127 air samples collected. These were predominantly L. pneumophila, serogroups 1-6. In contrast to the air samples, most of the water and sludge samples were positive for Legionella, again predominantly L. pneumophila, serogroups 1-6. The highest Legionella concentrations were found in sludge samples associated with condenser tube cleaning. Among the water samples, the highest Legionella concentrations were found in cooling towers, immediately after the tower basins were cleaned and refilled, and in condenser tubes. Two of the three cooling tower water samples collected prior to downtime operations were infectious for guinea pigs. 16 refs., 4 figs., 11 tabs.« less
Napoli, C; Tafuri, S; Montenegro, L; Cassano, M; Notarnicola, A; Lattarulo, S; Montagna, M T; Moretti, B
2012-02-01
To evaluate the level of microbial contamination of air in operating theatres using active [i.e. surface air system (SAS)] and passive [i.e. index of microbial air contamination (IMA) and nitrocellulose membranes positioned near the wound] sampling systems. Sampling was performed between January 2010 and January 2011 in the operating theatre of the orthopaedics department in a university hospital in Southern Italy. During surgery, the mean bacterial loads recorded were 2232.9 colony-forming units (cfu)/m(2)/h with the IMA method, 123.2 cfu/m(3) with the SAS method and 2768.2 cfu/m(2)/h with the nitrocellulose membranes. Correlation was found between the results of the three methods. Staphylococcus aureus was detected in 12 of 60 operations (20%) with the membranes, five (8.3%) operations with the SAS method, and three operations (5%) with the IMA method. Use of nitrocellulose membranes placed near a wound is a valid method for measuring the microbial contamination of air. This method was more sensitive than the IMA method and was not subject to any calibration bias, unlike active air monitoring systems. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
The purpose of this SOP is to describe the procedures for pre-cleaning filters and polyurethane foam (PUF) plug prior to air sampling with these media. The sampling media are used for sampling indoor air, outdoor air, and personal air. This procedure was followed to ensure consi...
Mold contamination in a controlled hospital environment: a 3-year surveillance in southern Italy.
Caggiano, Giuseppina; Napoli, Christian; Coretti, Caterina; Lovero, Grazia; Scarafile, Giancarlo; De Giglio, Osvalda; Montagna, Maria Teresa
2014-11-15
Environmental monitoring of airborne filamentous fungi is necessary to reduce fungal concentrations in operating theaters and in controlled environments, and to prevent infections. The present study reports results of a surveillance of filamentous fungi carried out on samples from air and surfaces in operating theaters and controlled environments in an Italian university hospital. Sampling was performed between January 2010 and December 2012 in 32 operating theaters and five departments with high-risk patients. Indoor air specimens were sampled using a microbiological air sampler; Rodac contact plates were used for surface sampling. Fungal isolates were identified at the level of genera and species. Sixty-one samples (61/465; 13.1%) were positive for molds, with 18 from controlled environments (18/81; 22.2%) and 43 (43/384; 11.2%) from operating theaters. The highest air fungal load (AFL, colony-forming units per cubic meter [CFU/m(3)]) was recorded in the ophthalmology operating theater, while the pediatric onco-hematology ward had the highest AFL among the wards (47 CFU/m(3)). The most common fungi identified from culture of air specimens were Aspergillus spp. (91.8%), Penicillium spp., (6%) and Paecilomyces spp. (1.5%). During the study period, a statistically significant increase in CFU over time was recorded in air-controlled environments (p = 0.043), while the increase in AFL in operating theaters was not statistically significant (p = 0.145). Molds were found in 29.1% of samples obtained from surfaces. Aspergillus fumigatus was the most commonly isolated (68.5%). Our findings will form the basis for action aimed at improving the air and surface quality of these special wards. The lack of any genetic analysis prevented any correlation of fungal environmental contamination with onset of fungal infection, an analysis that will be undertaken in a prospective study in patients admitted to the same hospital.
A BATTERY-OPERATED AIR SAMPLER FOR REMOTE AREAS
An air sampling system developed to evaluate air quality in biosphere reserves or in other remote areas is described. The equipment consists of a Dupont P-4000 pump and a specially designed battery pack containing Gates batteries. This air sampling system was tested in Southern U...
This SOP describes the procedures to set up, calibrate, initiate and terminate air sampling for persistent organic pollutants. This method is used to sample air, indoors and outdoors, at homes and at day care centers over a 48-hr period.
Davis, Meghan F; Pisanic, Nora; Rhodes, Sarah M; Brown, Alexis; Keller, Haley; Nadimpalli, Maya; Christ, Andrea; Ludwig, Shanna; Ordak, Carly; Spicer, Kristoffer; Love, David C; Larsen, Jesper; Wright, Asher; Blacklin, Sarah; Flowers, Billy; Stewart, Jill; Sexton, Kenneth G; Rule, Ana M; Heaney, Christopher D
2018-05-01
Occupational exposure to swine has been associated with increased Staphylococcus aureus carriage, including antimicrobial-resistant strains, and increased risk of infections. To characterize animal and environmental routes of worker exposure, we optimized methods to identify S. aureus on operations that raise swine in confinement with antibiotics (industrial hog operation: IHO) versus on pasture without antibiotics (antibiotic-free hog operation: AFHO). We associated findings from tested swine and environmental samples with those from personal inhalable air samplers on worker surrogates at one IHO and three AFHOs in North Carolina using a new One Health approach. We determined swine S. aureus carriage status by collecting swab samples from multiple anatomical sites, and we determined environmental positivity for airborne bioaerosols with inhalable and impinger samplers and a single-stage impactor (ambient air) cross-sectionally. All samples were analyzed for S. aureus, and isolates were tested for antimicrobial susceptibility, absence of scn (livestock marker), and spa type. Seventeen of twenty (85%) swine sampled at the one IHO carried S. aureus at >1 anatomical sites compared to none of 30 (0%) swine sampled at the three AFHOs. All S. aureus isolates recovered from IHO swine and air samples were scn negative and spa type t337; almost all isolates (62/63) were multidrug resistant. S. aureus was recovered from eight of 14 (67%) ambient air and two (100%) worker surrogate personal air samples at the one IHO, whereas no S. aureus isolates were recovered from 19 ambient and six personal air samples at the three AFHOs. Personal worker surrogate inhalable sample findings were consistent with both swine and ambient air data, indicating the potential for workplace exposure. IHO swine and the one IHO environment could be a source of potential pathogen exposure to workers, as supported by the detection of multidrug-resistant S. aureus (MDRSA) with livestock-associated spa type t337 among swine, worker surrogate personal air samplers and environmental air samples at the one IHO but none of the three AFHOs sampled in this study. Concurrent sampling of swine, personal swine worker surrogate air, and ambient airborne dust demonstrated that IHO workers may be exposed through both direct (animal contact) and indirect (airborne) routes of transmission. Investigation of the effectiveness of contact and respiratory protections is warranted to prevent IHO worker exposure to multidrug-resistant livestock-associated S. aureus and other pathogens. Copyright © 2017 Elsevier Inc. All rights reserved.
Near-infrared spectroscopy (NIRS) as a tool to monitor exhaust air from poultry operations.
Druckenmüller, Katharina; Günther, Klaus; Elbers, Gereon
2018-07-15
Intensive poultry operation systems emit a considerable volume of inorganic and organic matter in the surrounding environment. Monitoring cleaning properties of exhaust air cleaning systems and to detect small but significant changes in emission characteristics during a fattening cycle is important for both emission and fattening process control. In the present study, we evaluated the potential of near-infrared spectroscopy (NIRS) combined with chemometric techniques as a monitoring tool of exhaust air from poultry operation systems. To generate a high-quality data set for evaluation, the exhaust air of two poultry houses was sampled by applying state-of-the-art filter sampling protocols. The two stables were identical except for one crucial difference, the presence or absence of an exhaust air cleaning system. In total, twenty-one exhaust air samples were collected at the two sites to monitor spectral differences caused by the cleaning device, and to follow changes in exhaust air characteristics during a fattening period. The total dust load was analyzed by gravimetric determination and included as a response variable in multivariate data analysis. The filter samples were directly measured with NIR spectroscopy. Principal component analysis (PCA), linear discriminant analysis (LDA), and factor analysis (FA) were effective in classifying the NIR exhaust air spectra according to fattening day and origin. The results indicate that the dust load and the composition of exhaust air (inorganic or organic matter) substantially influence the NIR spectral patterns. In conclusion, NIR spectroscopy as a tool is a promising and very rapid way to detect differences between exhaust air samples based on still not clearly defined circumstances triggered during a fattening period and the availability of an exhaust air cleaning system. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
30 CFR 71.701 - Sampling; general requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Sampling; general requirements. 71.701 Section... MINES Airborne Contaminants § 71.701 Sampling; general requirements. (a) Air samples will be taken by... operator shall conduct any additional air sampling tests and analyses as the Secretary may from time to...
30 CFR 71.701 - Sampling; general requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Sampling; general requirements. 71.701 Section... MINES Airborne Contaminants § 71.701 Sampling; general requirements. (a) Air samples will be taken by... operator shall conduct any additional air sampling tests and analyses as the Secretary may from time to...
Genet, Chalachew; Kibru, Gebre; Tsegaye, Wondewosen
2011-03-01
Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital. A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher. The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively. Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.
Apollo Saturn 511 effluent measurements from the Apollo 16 launch operations: An experiment
NASA Technical Reports Server (NTRS)
Gregory, G. L.; Hulten, W. C.; Wornom, D. E.
1974-01-01
An experiment was performed in conjunction with the Apollo 16 launch to define operational and instrumentational problems associated with launch-vehicle exhaust effluent monitoring. Ground and airborne sampling were performed for CO, CO2, hydrocarbons, and particulates. Sampling systems included filter pads and photometers for particulates and whole-air grab samples for gases. Launch debris was identified in the particulate samples at ground level(taken immediately after launch) and in the airborne measurements (taken 40 to 50 minutes after launch approximately 40 km downwind of the pad). Operational problems were identified and included the need for higher instrumentation mobility and the need for real-time sampling instrumentation as opposed to collection-type samples such as the whole-air grab sample.
Air Pollution Potential from Electroplating Operations.
ERIC Educational Resources Information Center
Diamond, Philip
Measurements were made of emission rates from electroplating operations considered to have maximum air pollution potential. Sampling was performed at McClellan and additional data from a previous survey at Hill Air Force Base was used. Values obtained were extremely low. Based on existing Federal standards, no collectors are specifically required…
Five-year microbiological monitoring of wards and operating theatres in southern Italy.
La Fauci, V; Genovese, C; Facciolà, A; Palamara, M A R; Squeri, R
2017-06-01
Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination.
The objective of the procedure is to collect a representative sample concentration of total airborne fungal spores (viable and non-viable) that may be present in indoor air and in the outdoor air supplied to the space tested.
Genovese, C.; Facciolà, A.; Palamara, M.A.R.; Squeri, R.
2017-01-01
Summary Introduction. Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. Methods. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. Results. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Conclusions. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination. PMID:28900357
RadNet Sampling and Analyses Schedules
RadNet air monitors operate continuously and samples of air, precipitation and drinking water and analyzed on a routine schedule. RadNet can send deployable monitors to any U.S. location in the case of a radiological emergency.
The method for extracting and preparing indoor and outdoor air samples for analysis of polar persistent organic pollutants is summarized in this SOP. It covers the preparation of samples that are to be analyzed by gas chromatography/mass spectrometry.
This protocol describes how quality control samples should be handled in the field, and was designed as a quick reference source for the field staff. The protocol describes quality control samples for air-VOCs, air-particles, water samples, house dust, soil, urine, blood, hair, a...
Hurley, J.P.; McCollor, D.P.; Selle, S.J.
1994-07-26
A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during soot blowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon. 8 figs.
Hurley, John P.; McCollor, Don P.; Selle, Stanley J.
1994-01-01
A long duration ash probe includes a pressure shell connected to a port in a combustor with a sample coupon mounted on a retractable carriage so as to retract the sample coupon within the pressure shell during sootblowing operation of the combustor. A valve mounted at the forward end of the pressure shell is selectively closeable to seal the sample coupon within the shell, and a heating element in the shell is operable to maintain the desired temperature of the sample coupon while retracted within the shell. The carriage is operably mounted on a pair of rails within the shell for longitudinal movement within the shell. A hollow carrier tube connects the hollow cylindrical sample coupon to the carriage, and extends through the carriage and out the rearward end thereof. Air lines are connected to the rearward end of the carrier tube and are operable to permit coolant to pass through the air lines and thence through the carrier tube to the sample coupon so as to cool the sample coupon.
Innovations in Site Characterization Case Study: Hanscom Air Force Base, Operable Unit 1
This document is a condensation of the information provided in the much more detailed Hanscom AFB Report entitled A Dynamic Site Investigation: Adaptive Sampling and Analysis Program for Operable Unit 1 at Hanscom Air Force Base, Bedford, Massachusetts.
The purpose of this SOP is to describe the procedures for extracting and preparing an air sample consisting of a polyurethane foam (PUF) plug and Teflon-coated glass fiber filter (Pallflex T60A20) for analysis of pesticides. This procedure covers sample preparation for samples t...
40 CFR 1065.925 - PEMS preparation for field testing.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... 1065.925 Section 1065.925 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... purge any gaseous sampling PEMS instruments with ambient air until sampling begins to prevent system contamination from excessive cold-start emissions. (e) Conduct calibrations and verifications. (f) Operate any...
US EPA BASE Study Standard Operating Procedure for Sampling of Particulates
The objective of the procedure described is to collect a sample of particles of respirable and inhalable size (approx. 0.1 to 10 microns in diameter) from indoor air and from the outdoor air supplied to the indoor space tested.
Sampling and Analyzing Air Pollution: An Apparatus Suitable for Use in Schools.
ERIC Educational Resources Information Center
Rockwell, Dean M.; Hansen, Tony
1994-01-01
Describes two variations of an air sampler and analyzer that are inexpensive to construct, easy to operate, and designed to be used in an educational program. Variations use vacuum cleaners and aquarium pumps, and white facial tissues serve as filters. Samples of air pollution obtained by this method may be used from early grade school to advanced…
Volkova, V N; Mukhina, L P; Chistova, Zh A; Fedorova, S G
Polyoxin B being an effective inhibitor of synthesis of chitin of the cell wall of many phytopathogenic fungi, is recommended as a fungicide for control of phytopathogenic organisms that cause damage to crop. For the determination of the exposure of employees working with pesticides there was developed the method of the measurement of concentrations of polyoxin B in air of working area, atmospheric air of populated areas and washouts from the operators ’ integuments, based on high performance liquid chromatography with ultraviolet detector (detection wavelength of270 nm), including sampling air environment in the sorption tube ORBO-44, filled with sorbent XAD-2, extraction of the sorbent with polyoxin by a mixture of carbinol-water (in a ratio of 95:5,on volume), washout from the surface of the skin with ethyl alcohol by way of washing, concentrating, quantitative chromatographic analysis. Lower limits of the quantification ofpolyoxin B in the air ofworking area - 0.2 mg/m at the aspiration of 2 dm of air, atmospheric air - 0.016 mg/m at the aspiration of 25 dm of air, in washouts from the operators’ integuments - 0.4 pg/wash, the linear range of the defined concentrations accounted for of 0.2 - 2.4 pg/cm, the total error of measurement of the concentrations of polyoxin B in air is 17%; in washouts from the operators’ integuments - 16%. The developed method was approbated for the determination of polyoxin in samples of air of working zone, atmospheric air within the sanitary gap, washouts from the operators ’ integuments and air drift samples taken under processing of roses in the hothouse and in the monitoring of the phytosanitary condition of the plants every other day after treatment.
The method is for extracting an indoor and outdoor air sample consisting of a quartz fiber filter and an XAD-2 cartridge for analysis of neutral persistent organic pollutants. It covers the extraction and concentration of samples that are to be analyzed by gas chromatography/mass...
Air Sampling Data for BP Spill/Deepwater Horizon
The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following the explosion and sinking of the Deepwater Horizon oil rig, a sea-floor oil gusher flowed for 87 days, until it was capped on 15 July 2010.In response to the BP oil spill, EPA sampled air, water, sediment, and waste generated by the cleanup operations.
The purpose of this SOP is to describe the procedure for sampling personal air for metals and pesticides during a predetermined time period. The SOP includes the set up of the samplers for collection of either a metals sample or a pesticides sample, the calibration and initial c...
Does the air condition system in busses spread allergic fungi into driver space?
Sowiak, Małgorzata; Kozajda, Anna; Jeżak, Karolina; Szadkowska-Stańczyk, Irena
2018-02-01
The aim of this study was to establish whether the air-conditioning system in buses constitutes an additional source of indoor air contamination with fungi, and whether or not the fungi concentration depends on the period from the last disinfection of the system, combined with replacement of the cabin dust particle filter. The air samples to fungi analysis using impact method were taken in 30 buses (20 with an air-conditioning system, ACS; 10 with a ventilation system, VS) in two series: 1 and 22 weeks after cabin filter replacement and disinfection of the air-conditioning system. During one test in each bus were taken two samples: before the air-conditioning or ventilation system switched on and 6 min after operating of these systems. The atmospheric air was the external background (EB). After 1 week of use of the system, the fungi concentrations before starting of the ACS and VS system were 527.8 and 1053.0 cfu/m 3 , respectively, and after 22 weeks the concentrations were 351.9 and 1069.6 cfu/m 3 , respectively. While in the sample after 6 min of ACS and VS system operating, the fungi concentration after 1 week of use was 127.6 and 233.7 cfu/m 3 , respectively, and after 22 weeks it was 113.3 and 324.9 cfu/m 3 , respectively. Results do not provide strong evidence that air-conditioning system is an additional source of indoor air contamination with fungi. A longer operation of the system promoted increase of fungi concentration in air-conditioned buses only.
Erichsen Andersson, Annette; Petzold, Max; Bergh, Ingrid; Karlsson, Jón; Eriksson, Bengt I; Nilsson, Kerstin
2014-06-01
The importance of laminar airflow systems in operating rooms as protection from surgical site infections has been questioned. The aim of our study was to explore the differences in air contamination rates between displacement ventilation and laminar airflow systems during planned and acute orthopedic implant surgery. A second aim was to compare the influence of the number of people present, the reasons for traffic flow, and the door-opening rates between the 2 systems. Active air sampling and observations were made during 63 orthopedic implant operations. The laminar airflow system resulted in a reduction of 89% in colony forming units in comparison with the displacement system (P < .001). The air samples taken in the preparation rooms showed high levels of bacterial growth (≈ 40 CFU/m(3)). Our study shows that laminar airflow-ventilated operating rooms offer high-quality air during surgery, with very low levels of colony forming units close to the surgical wound. The continuous maintenance of laminar air flow and other technical systems are crucial, because minor failures in complex systems like those in operating rooms can result in a detrimental effect on air quality and jeopardize the safety of patients. The technical ventilation solutions are important, but they do not guarantee clean air, because many other factors, such as the organization of the work and staff behavior, influence air cleanliness. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
1981-01-01
Nation's first solar-cell-powered air monitoring station was installed at Liberty State Park, New Jersey. Jointly sponsored by state agencies and the Department of Energy, system includes display which describes its operation to park visitors. Unit samples air every sixth day for a period of 24 hours. Air is forced through a glass filter, then is removed each week for examination by the New Jersey Bureau of Air Pollution. During the day, solar cells provide total power for the sampling equipment. Excess energy is stored in a bank of lead-acid batteries for use when needed.
The objective of this procedure is to collect a representative sample of air containing volatile organic compound (VOC) contaminants present in an indoor environment using an evacuated canister, and to subsequently analyze the concentration of VOCs, as selected by EPA.
Tang, Chin-Sheng; Wan, Gwo-Hwa
2013-01-01
To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.
Carson, Christine F; Inglis, Timothy JJ
2018-01-01
This study investigated aerosolized viable bacteria in a university research laboratory during operation of an acoustic-assisted flow cytometer for antimicrobial susceptibility testing by sampling room air before, during and after flow cytometer use. The aim was to assess the risk associated with use of an acoustic-assisted flow cytometer analyzing unfixed bacterial suspensions. Air sampling in a nearby clinical laboratory was conducted during the same period to provide context for the existing background of microorganisms that would be detected in the air. The three species of bacteria undergoing analysis by flow cytometer in the research laboratory were Klebsiella pneumoniae, Burkholderia thailandensis and Streptococcus pneumoniae. None of these was detected from multiple 1000 L air samples acquired in the research laboratory environment. The main cultured bacteria in both locations were skin commensal and environmental bacteria, presumed to have been disturbed or dispersed in laboratory air by personnel movements during routine laboratory activities. The concentrations of bacteria detected in research laboratory air samples were reduced after interventional cleaning measures were introduced and were lower than those in the diagnostic clinical microbiology laboratory. We conclude that our flow cytometric analyses of unfixed suspensions of K. pneumoniae, B. thailandensis and S. pneumoniae do not pose a risk to cytometer operators or other personnel in the laboratory but caution against extrapolation of our results to other bacteria and/or different flow cytometric experimental procedures. PMID:29608197
System for autonomous monitoring of bioagents
Langlois, Richard G.; Milanovich, Fred P.; Colston, Jr, Billy W.; Brown, Steve B.; Masquelier, Don A.; Mariella, Jr., Raymond P.; Venkateswaran, Kodomudi
2015-06-09
An autonomous monitoring system for monitoring for bioagents. A collector gathers the air, water, soil, or substance being monitored. A sample preparation means for preparing a sample is operatively connected to the collector. A detector for detecting the bioagents in the sample is operatively connected to the sample preparation means. One embodiment of the present invention includes confirmation means for confirming the bioagents in the sample.
Can Particulate Air Sampling Predict Microbial Load in Operating Theatres for Arthroplasty?
Cristina, Maria Luisa; Spagnolo, Anna Maria; Sartini, Marina; Panatto, Donatella; Gasparini, Roberto; Orlando, Paolo; Ottria, Gianluca; Perdelli, Fernanda
2012-01-01
Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m3; the mean particle count was 4,194,569 no./m3 for particles of diameter ≥0.5 µm and 13,519 no./m3 for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres. PMID:23285189
Can particulate air sampling predict microbial load in operating theatres for arthroplasty?
Cristina, Maria Luisa; Spagnolo, Anna Maria; Sartini, Marina; Panatto, Donatella; Gasparini, Roberto; Orlando, Paolo; Ottria, Gianluca; Perdelli, Fernanda
2012-01-01
Several studies have proposed that the microbiological quality of the air in operating theatres be indirectly evaluated by means of particle counting, a technique derived from industrial clean-room technology standards, using airborne particle concentration as an index of microbial contamination. However, the relationship between particle counting and microbiological sampling has rarely been evaluated and demonstrated in operating theatres. The aim of the present study was to determine whether particle counting could predict microbiological contamination of the air in an operating theatre during 95 surgical arthroplasty procedures. This investigation was carried out over a period of three months in 2010 in an orthopedic operating theatre devoted exclusively to prosthetic surgery. During each procedure, the bacterial contamination of the air was determined by means of active sampling; at the same time, airborne particulate contamination was assessed throughout the entire procedure. On considering the total number of surgical operations, the mean value of the total bacterial load in the center of the operating theatre proved to be 35 CFU/m(3); the mean particle count was 4,194,569 no./m(3) for particles of diameter ≥0.5 µm and 13,519 no./m(3) for particles of diameter ≥5 µm. No significant differences emerged between the median values of the airborne microbial load recorded during the two types of procedure monitored. Particulates with a diameter of ≥0.5 µm were detected in statistically higher concentrations (p<0.001) during knee-replacement procedures. By contrast, particulates with a diameter of ≥5 µm displayed a statistically higher concentration during hip-replacement procedures (p<0.05). The results did not reveal any statistically significant correlation between microbial loads and particle counts for either of the particle diameters considered (≥0.5 µm and ≥5 µm). Consequently, microbiological monitoring remains the most suitable method of evaluating the quality of air in operating theatres.
Method, system and apparatus for monitoring and adjusting the quality of indoor air
Hartenstein, Steven D.; Tremblay, Paul L.; Fryer, Michael O.; Hohorst, Frederick A.
2004-03-23
A system, method and apparatus is provided for monitoring and adjusting the quality of indoor air. A sensor array senses an air sample from the indoor air and analyzes the air sample to obtain signatures representative of contaminants in the air sample. When the level or type of contaminant poses a threat or hazard to the occupants, the present invention takes corrective actions which may include introducing additional fresh air. The corrective actions taken are intended to promote overall health of personnel, prevent personnel from being overexposed to hazardous contaminants and minimize the cost of operating the HVAC system. The identification of the contaminants is performed by comparing the signatures provided by the sensor array with a database of known signatures. Upon identification, the system takes corrective actions based on the level of contaminant present. The present invention is capable of learning the identity of previously unknown contaminants, which increases its ability to identify contaminants in the future. Indoor air quality is assured by monitoring the contaminants not only in the indoor air, but also in the outdoor air and the air which is to be recirculated. The present invention is easily adaptable to new and existing HVAC systems. In sum, the present invention is able to monitor and adjust the quality of indoor air in real time by sensing the level and type of contaminants present in indoor air, outdoor and recirculated air, providing an intelligent decision about the quality of the air, and minimizing the cost of operating an HVAC system.
The purpose of this SOP is to describe methods for extracting and preparing an air sample consisting of a quartz fiber filter (Pallflex) and an XAD-2 cartridge for analysis of pesticides and polyaromatic hydrocarbons (PAHs). It covers the preparation of samples that are to be an...
McKernan, Lauralynn Taylor; Burge, Harriet; Wallingford, Kenneth M; Hein, Misty J; Herrick, Robert
2007-04-01
Given the potential health effects of fungi and the amount of time aircrew and passengers spend inside aircraft, it is important to study fungal populations in the aircraft environment. Research objectives included documenting the genera/species of airborne culturable fungal concentrations and total spore concentrations on a twin-aisle wide body commercial passenger aircraft. Twelve flights between 4.5 and 6.5 h in duration on Boeing 767 (B-767) aircraft were evaluated. Two air cooling packs and 50% recirculation rate (i.e. 50:50 mix of outside air and filtered inside air) were utilized during flight operations. Passenger occupancy rates varied from 67 to 100%. N-6 impactors and total spore traps were used to collect sequential, triplicate air samples in the front and rear of coach class during six sampling intervals throughout each flight: boarding, mid-climb, early cruise, mid-cruise, late cruise and deplaning. Comparison air samples were also collected inside and outside the airport terminals at the origin and destination cities resulting in a total of 522 culturable and 517 total spore samples. A total of 45 surface wipe samples were collected using swabs onboard the aircraft and inside the airport terminals. A variety of taxa were observed in the culturable and total spore samples. A frequency analysis of the fungal data indicated that Cladosporium, Aspergillus and Penicillium were predominant genera in the culturable samples whereas Cladosporium, Basidiospores and Penicillium/Aspergillus were predominant in the total spore samples. Fungal populations observed inside the aircraft were comprised of similar genera, detected significantly less frequently and with lower mean concentrations than those observed in typical office buildings. Although sources internal to the aircraft could not be ruled out, our data demonstrate the importance of passenger activity as the source of the fungi observed on aircraft. Isolated fungal peak events occurred occasionally when concentrations of a particular genus or species rose sharply inside the cabin for a limited period. Overall, our research demonstrates that on the sampled flights the B-767 filtration system operated efficiently to remove fungal spores when two air cooling packs and 50% recirculation rate were utilized during flight operations.
The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...
Study on Aerosol Penetration Through Clothing and Individual Protective Equipment
2009-05-01
8.4X10-3 mg.m-3 (2.57X105 particles per cubic meter of air) over a 30 minute period. This scenario represents a very high end threat with a large... Isokinetic air sampling was applied and the effect of aerosol losses in sampling lines and other parts of the test rig were incorporated in analysis...eliminate any “memory” effect. The aerosol sampling (airflow direction control, start of sampling) was operated manually. Isokinetic sampling conditions
Tang, Chin-Sheng; Wan, Gwo-Hwa
2013-01-01
To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers. PMID:23573296
2006-08-15
Programs Section 3. Sampling Equipment Sampling Equipment Solid-State Army Miniature (SSAM) trap ABC style trap Encephalitis Vector Survey Trap CDC...Baseline Survey - these are conducted to determine the types of vectors and pests occurring in the area of operations, their respective breeding sites...or source habitat, and seasonal activity patterns. Operational Survey - data collected in an operational survey are used specifically to aid pest
Solubility testing of actinides on breathing-zone and area air samples
NASA Astrophysics Data System (ADS)
Metzger, Robert Lawrence
The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine plant operations. The solubility profiles developed from this work showed excellent agreement with the results of the worker urine bioassay program at the plant and identified a significant error in existing internal dose assessments at this facility.
Stauning, M T; Bediako-Bowan, A; Andersen, L P; Opintan, J A; Labi, A-K; Kurtzhals, J A L; Bjerrum, S
2018-07-01
Current literature examining the relationship between door-opening rate, number of people present, and microbial air contamination in the operating room is limited. Studies are especially needed from low- and middle-income countries, where the risk of surgical site infections is high. To assess microbial air contamination in operating rooms at a Ghanaian teaching hospital and the association with door-openings and number of people present. Moreover, we aimed to document reasons for door-opening. We conducted active air-sampling using an MAS 100 ® portable impactor during 124 clean or clean-contaminated elective surgical procedures. The number of people present, door-opening rate and the reasons for each door-opening were recorded by direct observation using pretested structured observation forms. During surgery, the mean number of colony-forming units (cfu) was 328 cfu/m 3 air, and 429 (84%) of 510 samples exceeded a recommended level of 180 cfu/m 3 . Of 6717 door-openings recorded, 77% were considered unnecessary. Levels of cfu/m 3 were strongly correlated with the number of people present (P = 0.001) and with the number of door-openings/h (P = 0.02). In empty operating rooms, the mean cfu count was 39 cfu/m 3 after 1 h of uninterrupted ventilation and 52 (51%) of 102 samples exceeded a recommended level of 35 cfu/m 3 . The study revealed high values of intraoperative airborne cfu exceeding recommended levels. Minimizing the number of door-openings and people present during surgery could be an effective strategy to reduce microbial air contamination in low- and middle-income settings. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Evaluation of ELISA screening test for detecting aflatoxin in biogenic dust samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durant, J.T.
Aflatoxin is a carcinogenic chemical that is sometimes produced when agricultural commodities are infested by the fungi Aspergillus flavus and A. Parasiticus. Aflatoxin has been found to be present in air samples taken around persons handling materials likely to be contaminated. The purpose of this investigation was to demonstrate the feasibility of using an Enzyme Linked Immunosorbent Assay (ELISA) test kit that was developed to screen for aflatoxin in bulk agricultural commodities, to an air sample. Samples were taken from two environments likely to be contaminated with aflatoxin, a dairy farm feed mixing operation and a peanut bagging operation. Themore » dust collected from these environments was considered to be biogenic, in that it originated primarily from biological materials.« less
Evaluation of Air Coupled Ultrasound for Composite Aerospace Structure
NASA Astrophysics Data System (ADS)
Tat, H.; Georgeson, G.; Bossi, R.
2009-03-01
Non-contact air coupled ultrasound suffers from the high acoustic impedance mismatch characteristics of air to solid interfaces. Advances in transducer technology, particularly MEMS, have improved the acoustic impedance match at the transmission stage and the signal to noise at the reception stage. Comparisons of through transmission (TTU) scanning of laminate and honeycomb test samples using conventional piezoelectric air coupled transducers, new MEMS air coupled transducers, and standard water coupled inspections have been performed to assess the capability. An additional issue for air coupled UT inspection is the need for a lean implementation for both manufacturing and in-service operations. Concepts and applications utilizing magnetic coupling of transducers have been developed that allows air coupled inspection operations in compact low cost configurations.
The document is a recommended operating procedure, prepare or use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The procedure applies to the collection of gaseous grab samples from fossil fuel combustion sources for subsequent a...
RECOMMENDED OPERATING PROCEDURE NO. 51: GLASS SOURCE ASSESSMENT SAMPLING SYSTEM (GLASS SASS)
The report is a recommended operating procedure (ROP), prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). he method described is applicable to the stack sampling of flue gas from a rotary kiln and to associated equip...
Drop transfer between superhydrophobic wells using air logic control.
Vuong, Thach; Cheong, Brandon Huey-Ping; Huynh, So Hung; Muradoglu, Murat; Liew, Oi Wah; Ng, Tuck Wah
2015-02-21
Superhydrophobic surfaces aid biochemical analysis by limiting sample loss. A system based on wells here tolerated tilting up to 20° and allowed air logic transfer with evidence of mixing. Conditions for intact transfer on 15 to 60 μL drops using compressed air pressure operation were also mapped.
40 CFR 86.521-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... apparatus. The methanol is vaporized and swept into the sample bag with a known volume of zero grade air....521-90 Section 86.521-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... and basic operating adjustment using the appropriate FID fuel and zero-grade air. (2) Optimize on the...
40 CFR 86.1221-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... apparatus. The methanol is vaporized and swept into the sample bag with a known volume of zero grade air....1221-90 Section 86.1221-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... appropriate FID fuel and zero-grade air. (2) Optimize on the most common operating range. Introduce into the...
40 CFR 86.521-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... apparatus. The methanol is vaporized and swept into the sample bag with a known volume of zero grade air....521-90 Section 86.521-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... and basic operating adjustment using the appropriate FID fuel and zero-grade air. (2) Optimize on the...
40 CFR 86.121-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sample bag with a known volume of zero grade air measured by a gas flow meter meeting the performance....121-90 Section 86.121-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... operating adjustment using the appropriate FID fuel and zero-grade air. (2) Optimize on the most common...
40 CFR 86.121-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sample bag with a known volume of zero grade air measured by a gas flow meter meeting the performance....121-90 Section 86.121-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... operating adjustment using the appropriate FID fuel and zero-grade air. (2) Optimize on the most common...
40 CFR 86.1221-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... apparatus. The methanol is vaporized and swept into the sample bag with a known volume of zero grade air....1221-90 Section 86.1221-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... appropriate FID fuel and zero-grade air. (2) Optimize on the most common operating range. Introduce into the...
Combined analysis of job and task benzene air exposures among workers at four US refinery operations
Shin, Jennifer (Mi); Unice, Ken M; Gaffney, Shannon H; Kreider, Marisa L; Gelatt, Richard H; Panko, Julie M
2016-01-01
Workplace air samples analyzed for benzene at four US refineries from 1976 to 2007 were pooled into a single dataset to characterize similarities and differences between job titles, tasks and refineries, and to provide a robust dataset for exposure reconstruction. Approximately 12,000 non-task (>180 min) personal samples associated with 50 job titles and 4000 task (<180 min) samples characterizing 24 tasks were evaluated. Personal air sample data from four individual refineries were pooled based on a number of factors including (1) the consistent sampling approach used by refinery industrial hygienists over time, (2) the use of similar exposure controls, (3) the comparability of benzene content of process streams and end products, (4) the ability to assign uniform job titles and task codes across all four refineries, and (5) our analysis of variance (ANOVA) of the distribution of benzene air concentrations for select jobs/tasks across all four refineries. The jobs and tasks most frequently sampled included those with highest potential contact with refinery product streams containing benzene, which reflected the targeted sampling approach utilized by the facility industrial hygienists. Task and non-task data were analyzed to identify and account for significant differences within job-area, task-job, and task-area categories. This analysis demonstrated that in general, areas with benzene containing process streams were associated with greater benzene air concentrations compared to areas with process streams containing little to no benzene. For several job titles and tasks analyzed, there was a statistically significant decrease in benzene air concentration after 1990. This study provides a job and task-focused analysis of occupational exposure to benzene during refinery operations, and it should be useful for reconstructing refinery workers’ exposures to benzene over the past 30 years. PMID:26862134
Burns, Amanda; Shin, Jennifer Mi; Unice, Ken M; Gaffney, Shannon H; Kreider, Marisa L; Gelatt, Richard H; Panko, Julie M
2017-03-01
Workplace air samples analyzed for benzene at four US refineries from 1976 to 2007 were pooled into a single dataset to characterize similarities and differences between job titles, tasks and refineries, and to provide a robust dataset for exposure reconstruction. Approximately 12,000 non-task (>180 min) personal samples associated with 50 job titles and 4000 task (<180 min) samples characterizing 24 tasks were evaluated. Personal air sample data from four individual refineries were pooled based on a number of factors including (1) the consistent sampling approach used by refinery industrial hygienists over time, (2) the use of similar exposure controls, (3) the comparability of benzene content of process streams and end products, (4) the ability to assign uniform job titles and task codes across all four refineries, and (5) our analysis of variance (ANOVA) of the distribution of benzene air concentrations for select jobs/tasks across all four refineries. The jobs and tasks most frequently sampled included those with highest potential contact with refinery product streams containing benzene, which reflected the targeted sampling approach utilized by the facility industrial hygienists. Task and non-task data were analyzed to identify and account for significant differences within job-area, task-job, and task-area categories. This analysis demonstrated that in general, areas with benzene containing process streams were associated with greater benzene air concentrations compared to areas with process streams containing little to no benzene. For several job titles and tasks analyzed, there was a statistically significant decrease in benzene air concentration after 1990. This study provides a job and task-focused analysis of occupational exposure to benzene during refinery operations, and it should be useful for reconstructing refinery workers' exposures to benzene over the past 30 years.
Macey, Gregg P; Breech, Ruth; Chernaik, Mark; Cox, Caroline; Larson, Denny; Thomas, Deb; Carpenter, David O
2014-10-30
Horizontal drilling, hydraulic fracturing, and other drilling and well stimulation technologies are now used widely in the United States and increasingly in other countries. They enable increases in oil and gas production, but there has been inadequate attention to human health impacts. Air quality near oil and gas operations is an underexplored human health concern for five reasons: (1) prior focus on threats to water quality; (2) an evolving understanding of contributions of certain oil and gas production processes to air quality; (3) limited state air quality monitoring networks; (4) significant variability in air emissions and concentrations; and (5) air quality research that misses impacts important to residents. Preliminary research suggests that volatile compounds, including hazardous air pollutants, are of potential concern. This study differs from prior research in its use of a community-based process to identify sampling locations. Through this approach, we determine concentrations of volatile compounds in air near operations that reflect community concerns and point to the need for more fine-grained and frequent monitoring at points along the production life cycle. Grab and passive air samples were collected by trained volunteers at locations identified through systematic observation of industrial operations and air impacts over the course of resident daily routines. A total of 75 volatile organics were measured using EPA Method TO-15 or TO-3 by gas chromatography/mass spectrometry. Formaldehyde levels were determined using UMEx 100 Passive Samplers. Levels of eight volatile chemicals exceeded federal guidelines under several operational circumstances. Benzene, formaldehyde, and hydrogen sulfide were the most common compounds to exceed acute and other health-based risk levels. Air concentrations of potentially dangerous compounds and chemical mixtures are frequently present near oil and gas production sites. Community-based research can provide an important supplement to state air quality monitoring programs.
Tissue-based standoff biosensors for detecting chemical warfare agents
Greenbaum, Elias; Sanders, Charlene A.
2003-11-18
A tissue-based, deployable, standoff air quality sensor for detecting the presence of at least one chemical or biological warfare agent, includes: a cell containing entrapped photosynthetic tissue, the cell adapted for analyzing photosynthetic activity of the entrapped photosynthetic tissue; means for introducing an air sample into the cell and contacting the air sample with the entrapped photosynthetic tissue; a fluorometer in operable relationship with the cell for measuring photosynthetic activity of the entrapped photosynthetic tissue; and transmitting means for transmitting analytical data generated by the fluorometer relating to the presence of at least one chemical or biological warfare agent in the air sample, the sensor adapted for deployment into a selected area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniels, W.J.; Gunter, B.
1987-07-01
In response to a request from employees to evaluate exposures to waste anesthetic gases and vapors at the Presbyterian Day Surgery Unit, located in Albuquerque, New Mexico, personal and area air-sampling and leak-detection testing was carried out for nitrous oxide (N/sub 2/O) and halogenated anesthetic agents in the six operating rooms at the facility. Nitrous oxide concentrations ranged from not detectable to 95 parts per million (ppm) with a mean of 20ppm. Five of the samples exceeded the NIOSH limit of 25ppm for N/sub 2/O during anesthetic administration. Ethrane levels in 14 personal and area air samples ranged from lessmore » than the limit of detection to 3.63ppm with a mean of 0.31ppm. Isoflurane and halothane were below the limits of detection. The ventilation system in use changed the air in excess of 20 times per hour. However, during a portion of surgical procedures the system was not operating, resulting in a higher than normal exposure level in three of the operating rooms.« less
Results from the Space Shuttle STS-95 Electronic Nose Experiment
NASA Technical Reports Server (NTRS)
Ryan, M. A.; Buehler, M. G.; Homer, M. L.; Mannatt, K. S.; Lau, B.; Jackson, S.; Zhou, H.
2000-01-01
A miniature electronic nose in which the sensing media are insulating polymers loaded with carbon black as a conductive medium has been designed and built at the Jet Propulsion Laboratory. The ENose has a volume of 1700 cc, weighs 1.4 kg including the operating computer, and uses 1.5 W average power (3 W peak power). This ENose was used in a demonstration experiment aboard STS-95 (October, 1998), in which the ENose was operated continuously for six days and recorded the sensors' response to the air in the middeck. The ENose was designed to detect ten common contaminants in space shuttle crew quarters air. The experiment was controlled by collecting air samples daily and analyzing them using standard analytical techniques after the flight. Changes in humidity were detected and quantified, neither the ENose nor the air samples detected any of the contaminants on the target list. The device is microgravity insensitive.
PM2.5 Monitors in New England | Air Quality Planning Unit ...
2017-04-10
The New England states are currently operating a network of 58 ambient PM2.5 air quality monitors that meet EPA's Federal Reference Method (FRM) for PM2.5, which is necessary in order for the resultant data to be used for attainment/non-attainment purposes. These monitors collect particles in the ambient air smaller than 2.5 microns in size on a filter, which is weighed prior and post sampling to produce a 24-hour sample concentration.
NASA Astrophysics Data System (ADS)
Peterson, Karl
Since the discovery in the late 1930s that air entrainment can improve the durability of concrete, it has been important for people to know the quantity, spacial distribution, and size distribution of the air-voids in their concrete mixes in order to ensure a durable final product. The task of air-void system characterization has fallen on the microscopist, who, according to a standard test method laid forth by the American Society of Testing and Materials, must meticulously count or measure about a thousand air-voids per sample as exposed on a cut and polished cross-section of concrete. The equipment used to perform this task has traditionally included a stereomicroscope, a mechanical stage, and a tally counter. Over the past 30 years, with the availability of computers and digital imaging, automated methods have been introduced to perform the same task, but using the same basic equipment. The method described here replaces the microscope and mechanical stage with an ordinary flatbed desktop scanner, and replaces the microscopist and tally counter with a personal computer; two pieces of equipment much more readily available than a microscope with a mechanical stage, and certainly easier to find than a person willing to sit for extended periods of time counting air-voids. Most laboratories that perform air-void system characterization typically have cabinets full of prepared samples with corresponding results from manual operators. Proponents of automated methods often take advantage of this fact by analyzing the same samples and comparing the results. A similar iterative approach is described here where scanned images collected from a significant number of samples are analyzed, the results compared to those of the manual operator, and the settings optimized to best approximate the results of the manual operator. The results of this calibration procedure are compared to an alternative calibration procedure based on the more rigorous digital image accuracy assessment methods employed primarily by the remote sensing/satellite imaging community.
The impact of air pollution from the coal-fired Columbia Generating Station upon vegetation was investigated. Air monitoring of 03 and 02 documented levels that occurred before and with operation of the generating station. Field sampling of alfalfa, lichens, and white pines was u...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fritz, Brad G.; Patton, Gregory W.
2006-01-01
While other research has reported on the concentrations of 129I in the environment surrounding active nuclear fuel reprocessing facilities, there is a shortage of information regarding how the concentrations change once facilities close. At the Hanford Site, the Plutonium-Uranium Extraction (PUREX) chemical separation plant was operational between 1983 and 1990, during which time 129I concentrations in air and milk were measured. After the cessation of operations in 1990, plant emissions decreased 2.5 orders of magnitude over an 8 year period, and monitoring of environmental levels continued. An evaluation of air and milk 129I concentration data spanning the PUREX operation andmore » post closure period was conducted to compare the changes in environmental levels of 129I measured. Measured concentrations over the monitoring period were below levels that could result in a potential human dose greater than 10 uSv. There was a significant and measurable difference in the measured air concentrations of 129I at different distances from the source, indicating a distinct Hanford fingerprint. Correlations between stack emissions of 129I and concentrations in air and milk indicate that atmospheric emissions were responsible for the 129I concentrations measured in environmental samples. The measured concentrations during PUREX operation were similar to observations made around a fuel reprocessing plant in Germany.« less
Vincent, R; Poirot, P; Subra, I; Rieger, B; Cicolella, A
1994-01-01
The exposure of workers to methylene chloride and phenol in an aeronautical workshop was measured during stripping of paint from a Boeing B 747. Methylene chloride exposure was measured during two work days by personal air sampling, while area sampling was used for phenol. During paint stripping operations, methylene chloride air concentrations ranged from 299.2 mg/m3 (83.1 ppm) to 1888.9 mg/m3 (524.7 ppm). The exposures to methylene chloride calculated for an 8-h work day ranged from 86 mg/m3 (23.9 ppm) to 1239.5 mg/m3 (344.3 ppm). In another aeronautical workshop, exposure to organic solvents, especially ethylene glycol monoethylether acetate (EGEEA), was controlled during the painting of an Airbus A 320. The external exposure to solvents and EGEEA was measured by means of individual air sampling. The estimation of internal exposure to EGEEA was made by measuring its urinary metabolite, ethoxyacetic acid (EAA). Both measurements were made during the course of 3 days. The biological samples were taken pre- and post-shift. During painting operations, methyl ethyl ketone, ethyl acetate, n-butyl alcohol, methyl isobutyl ketone, toluene, n-butyl acetate, ethylbenzene, xylenes and EGEEA were detected in working atmospheres. For these solvents, air concentrations ranged from 0.1 ppm to 69.1 ppm. EGEEA concentrations ranged from 29.2 mg/m3 (5.4 ppm) to 150.1 mg/m3 (27.8 ppm). For biological samples, the average concentrations of EAA were 108.4 mg/g creatinine in pre-shift and 139.4 mg/g creatinine in post-shift samples. Despite the fact that workers wore protective respiratory equipment during paint spraying operations, EEA urinary concentrations are high and suggest that percutaneous uptake is the main route of exposure for EGEEA.(ABSTRACT TRUNCATED AT 250 WORDS)
Thomas, Stephanie; Palmer, Rish; Phillipo, Edward; Chipungu, Geoffrey
2016-05-31
All surgical procedures have the potential for infection and some of the main sources are contamination from airborne particles, theatre personnel and the theatre environment. There is strong evidence that the use of ultra-clean air flow systems in orthopedic operating theatres reduces the incidence of deep sepsis after surgery. In the developing world however, this is often an unrealistic solution. The aim of this study was to establish baseline levels of contamination in a working orthopedic theatre, at the Queen Elizabeth Central Hospital, Blantyre, Malawi. To feedback results to the theatre team, promote infection prevention discussion and work with the team to implement workable and realistic goals to improve the intra-operative environment. Samples were collected from theatre equipment available at the time of surgery, from theatre water and theatre air using passive air sampling techniques. Samples were immediately transferred to the Central Microbiology Laboratory for culture on basic culture media. Bacterial contamination of theatre equipment, intra-operative theatre air and water was detected. Results were discussed with the theatre and infection prevention team who were receptive to feedback with regards to infection prevention strategies and keen to develop simple measures which could be put in place to change practice. In this setting, we suggest that implementing workable and realistic goals such as, establishing baseline rates of bacterial contamination and introduction of strict protocols for asepsis and theatre etiquette, may reduce bacterial contamination rates and subsequent intra-operative infection in the absence of expensive engineering solutions.
What is EPA Doing about Pet Coke in Chicago?
In response to complaints of windblown dust believed to originate from petroleum coke (petcoke) storage pile sites, operated by KCBX Terminals and Beemsterboer Slag; EPA ordered sample analysis and air quality monitoring under the Clean Air Act.
NASA Technical Reports Server (NTRS)
Galen, T. J. (Inventor)
1986-01-01
A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.
Hammond, Duane R.; Shulman, Stanley A.; Echt, Alan S.
2016-01-01
Asphalt pavement milling machines use a rotating cutter drum to remove the deteriorated road surface for recycling. The removal of the road surface has the potential to release respirable crystalline silica, to which workers can be exposed. This paper describes an evaluation of respirable crystalline silica exposures to the operator and ground worker from two different half-lane and larger asphalt pavement milling machines that had ventilation dust controls and water-sprays designed and installed by the manufacturers. Manufacturer A completed milling for eleven days at four highway construction sites in Wisconsin, while Manufacturer B completed milling for ten days at seven highway construction sites in Indiana. To evaluate the dust controls, full-shift personal breathing zone air samples were collected from an operator and ground worker during the course of normal employee work activities of asphalt pavement milling at eleven different sites. Forty-two personal breathing zone air samples were collected over 21 days (sampling on an operator and ground worker each day). All samples were below 50 µg/m3 for respirable crystalline silica, the National Institute for Occupational Safety and Health recommended exposure limit. The geometric mean personal breathing zone air sample was 6.2 µg/m3 for the operator and 6.1 µg/m3 for the ground worker for the Manufacturer A milling machine. The geometric mean personal breathing zone air sample was 4.2 µg/m3 for the operator and 9.0 µg/m3 for the ground worker for the Manufacturer B milling machine. In addition, upper 95% confidence limits for the mean exposure for each occupation were well below 50 µg/m3 for both studies. The silica content in the bulk asphalt material being milled ranged from 7% to 23% silica for roads milled by Manufacturer A and from 5% to 12% silica for roads milled by Manufacturer B. The results indicate that engineering controls consisting of ventilation controls in combination with water-sprays are capable of controlling occupational exposures to respirable crystalline silica generated by asphalt pavement milling machines on highway construction sites. PMID:26913983
Hammond, Duane R; Shulman, Stanley A; Echt, Alan S
2016-07-01
Asphalt pavement milling machines use a rotating cutter drum to remove the deteriorated road surface for recycling. The removal of the road surface has the potential to release respirable crystalline silica, to which workers can be exposed. This article describes an evaluation of respirable crystalline silica exposures to the operator and ground worker from two different half-lane and larger asphalt pavement milling machines that had ventilation dust controls and water-sprays designed and installed by the manufacturers. Manufacturer A completed milling for 11 days at 4 highway construction sites in Wisconsin, and Manufacturer B completed milling for 10 days at 7 highway construction sites in Indiana. To evaluate the dust controls, full-shift personal breathing zone air samples were collected from an operator and ground worker during the course of normal employee work activities of asphalt pavement milling at 11 different sites. Forty-two personal breathing zone air samples were collected over 21 days (sampling on an operator and ground worker each day). All samples were below 50 µg/m(3) for respirable crystalline silica, the National Institute for Occupational Safety and Health recommended exposure limit. The geometric mean personal breathing zone air sample was 6.2 µg/m(3) for the operator and 6.1 µg/m(3) for the ground worker for the Manufacturer A milling machine. The geometric mean personal breathing zone air sample was 4.2 µg/m(3) for the operator and 9.0 µg/m(3) for the ground worker for the Manufacturer B milling machine. In addition, upper 95% confidence limits for the mean exposure for each occupation were well below 50 µg/m(3) for both studies. The silica content in the bulk asphalt material being milled ranged from 7-23% silica for roads milled by Manufacturer A and from 5-12% silica for roads milled by Manufacturer B. The results indicate that engineering controls consisting of ventilation controls in combination with water-sprays are capable of controlling occupational exposures to respirable crystalline silica generated by asphalt pavement milling machines on highway construction sites.
Najotra, Dipender Kaur; Malhotra, Aneeta Singh; Slathia, Poonam; Raina, Shivani; Dhar, Ashok
2017-01-01
Introduction: Microbiological contamination of air and environment in the operation theaters (OTs) are major risk factor for surgical site and other hospital-associated infections. Objectives: The aim was to identify bacterial colonization of surfaces and equipment and to determine the microbial contamination of air in the OTs of a tertiary care hospital. Materials and Methods: Five years (January 2010–December 2014) retrospective analysis of the data obtained from routine microbiological surveillance of the five OTs of the hospital was done. Surface samples were taken with wet swabs from different sites and equipment. Bacterial species were isolated and identified by conventional methods. Air quality surveillance of OTs was done by settle plate method. Results: A total of 4387 samples were collected from surfaces and articles of various OTs. Out of these only 195 (4.4%), samples showed bacterial growth and yielded 210 isolates. The predominant species isolated was Bacillus with 184 (87.6%) isolates followed by coagulase-negative Staphylococcus 17 (8.1%), Staphylococcus aureus 6 (2.9%), and Enteroccoccus spp. 3 (1.4%). Analysis of the OT air samples showed least colony forming unit (cfu) rate of air (27 cfu/m3) in ophthalmology OT and highest rate of 133 cfu/m3 in general surgery OT. Conclusion: The study shows that OTs of our hospital showed a very low bacterial contamination rate on surface swabbing and a cfu count per m3 of air well within permissible limits. PMID:28904915
NASA aviation safety reporting system
NASA Technical Reports Server (NTRS)
1978-01-01
The study deals with 165 inadvertent operations on or into inappropriate portions of the aircraft areas at controlled airports. Pilot-initiated and controller-initiated incursions are described and discussed. It was found that a majority of the pilot-initiated occurrences involved operation without a clearance; controller-initiated occurrences usually involved failure to maintain assured separation. The factors associated with these occurrences are analyzed. It appears that a major problem in these occurrences is inadequate coordination among the various system participants. Reasons for this, and some possible solutions to various aspects of the problem, are discussed. A sample of reports from pilots and controllers is presented. These relate to undesired occurrences in air transport, general aviation, and air traffic control operations; to ATC coordination problems; and to a recurrent problem in ASRS reports, parachuting operations. A sample of alert bulletins and responses to them is presented.
Polyport atmospheric gas sampler
Guggenheim, S. Frederic
1995-01-01
An atmospheric gas sampler with a multi-port valve which allows for multi, sequential sampling of air through a plurality of gas sampling tubes mounted in corresponding gas inlet ports. The gas sampler comprises a flow-through housing which defines a sampling chamber and includes a gas outlet port to accommodate a flow of gases through the housing. An apertured sample support plate defining the inlet ports extends across and encloses the sampling chamber and supports gas sampling tubes which depend into the sampling chamber and are secured across each of the inlet ports of the sample support plate in a flow-through relation to the flow of gases through the housing during sampling operations. A normally closed stopper means mounted on the sample support plate and operatively associated with each of the inlet ports blocks the flow of gases through the respective gas sampling tubes. A camming mechanism mounted on the sample support plate is adapted to rotate under and selectively lift open the stopper spring to accommodate a predetermined flow of gas through the respective gas sampling tubes when air is drawn from the housing through the outlet port.
Ozone measurement system for NASA global air sampling program
NASA Technical Reports Server (NTRS)
Tiefermann, M. W.
1979-01-01
The ozone measurement system used in the NASA Global Air Sampling Program is described. The system uses a commercially available ozone concentration monitor that was modified and repackaged so as to operate unattended in an aircraft environment. The modifications required for aircraft use are described along with the calibration techniques, the measurement of ozone loss in the sample lines, and the operating procedures that were developed for use in the program. Based on calibrations with JPL's 5-meter ultraviolet photometer, all previously published GASP ozone data are biased high by 9 percent. A system error analysis showed that the total system measurement random error is from 3 to 8 percent of reading (depending on the pump diaphragm material) or 3 ppbv, whichever are greater.
Recovery of Waste Heat from Propellant Forced-Air Dry House
1978-12-01
function of bulk air side film heat transfer coefficient and diffusivity 66 15. Dry house waste heat recovery system instrumentation 67 16. Sample data...inlet condition by, maintaining the exhaust temperature above the NG dew point. The set point is adjustable to accommodate various propel- lant and...system. In dry cycle operation, an overall energy recovery effectiveness of about 40% was measured for winter operation when the exhaust temperature
Moorman, William J; Reutman, Susan S; Shaw, Peter B; Blade, Leo Michael; Marlow, David; Vesper, Hubert; Clark, John C; Schrader, Steven M
2012-01-01
The aim of this study was to evaluate biomarkers of acrylamide exposure, including hemoglobin adducts and urinary metabolites in acrylamide production workers. Biomarkers are integrated measures of the internal dose, and it is total acrylamide dose from all routes and sources that may present health risks. Workers from three companies were studied. Workers potentially exposed to acrylamide monomer wore personal breathing-zone air samplers. Air samples and surface-wipe samples were collected and analyzed for acrylamide. General-area air samples were collected in chemical processing units and control rooms. Hemoglobin adducts were isolated from ethylenediamine teraacetic acid (EDTA)-whole blood, and adducts of acrylamide and glycidamide, at the N-terminal valines of hemoglobin, were cleaved from the protein chain by use of a modified Edman reaction. Full work-shift, personal breathing zone, and general-area air samples were collected and analyzed for particulate and acrylamide monomer vapor. The highest general-area concentration of acrylamide vapor was 350 μg/cm(3) in monomer production. Personal breathing zone and general-area concentrations of acrylamide vapor were found to be highest in monomer production operations, and lower levels were in the polymer production operations. Adduct levels varied widely among workers, with the highest in workers in the monomer and polymer production areas. The acrylamide adduct range was 15-1884 pmol/g; glycidamide adducts ranged from 17.8 to 1376 p/mol/g. The highest acrylamide and glycidamide adduct levels were found among monomer production process operators. The primary urinary metabolite N-acetyl-S-(2-carbamoylethyl) cysteine (NACEC) ranged from the limit of detection to 15.4 μg/ml. Correlation of workplace exposure and sentinel health effects is needed to determine and control safe levels of exposure for regulatory standards.
Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)
NASA Technical Reports Server (NTRS)
Neustadter, H. E.; Sidik, S. M.; King, R. B.; Fordyce, J. S.; Burr, J. C.
1974-01-01
The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.
Brand, Willi A; Rothe, Michael; Sperlich, Peter; Strube, Martin; Wendeberg, Magnus
2016-07-15
The isotopic composition of greenhouse gases helps to constrain global budgets and to study sink and source processes. We present a new system for high-precision stable isotope measurements of carbon, hydrogen and oxygen in atmospheric methane and carbon dioxide. The design is intended for analyzing flask air samples from existing sampling programs without the need for extra sample air for methane analysis. CO2 and CH4 isotopes are measured simultaneously using two isotope ratio mass spectrometers, one for the analysis of δ(13) C and δ(18) O values and the second one for δ(2) H values. The inlet carousel delivers air from 16 sample positions (glass flasks 1-5 L and high-pressure cylinders). Three 10-port valves take aliquots from the sample stream. CH4 from 100-mL air aliquots is preconcentrated in 0.8-mL sample loops using a new cryo-trap system. A precisely calibrated working reference air is used in parallel with the sample according to the Principle of Identical Treatment. It takes about 36 hours for a fully calibrated analysis of a complete carousel including extractions of four working reference and one quality control reference air. Long-term precision values, as obtained from the quality control reference gas since 2012, account for 0.04 ‰ (δ(13) C values of CO2 ), 0.07 ‰ (δ(18) O values of CO2 ), 0.11 ‰ (δ(13) C values of CH4 ) and 1.0 ‰ (δ(2) H values of CH4 ). Within a single day, the system exhibits a typical methane δ(13) C standard deviation (1σ) of 0.06 ‰ for 10 repeated measurements. The system has been in routine operation at the MPI-BGC since 2012. Consistency of the data and compatibility with results from other laboratories at a high precision level are of utmost importance. A high sample throughput and reliability of operation are important achievements of the presented system to cope with the large number of air samples to be analyzed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
MONITORING ENVIRONMENTAL RADIATION IN THE UNITED STATES(RADNET)
Operate a national network of sampling stations that regularly submit environmental samples of air, precipitation and drinking water; analyze all samples for radiation at the laboratory; and report data to the public and the radiation protection community. During national radiat...
The purpose of this SOP is to describe the in-field use of the modified Air Sentinel. Samples collected with this Hi-Vol instrument were analyzed for atmospheric concentrations of target metals. This procedure was followed to ensure consistent data retrieval of air and dust ana...
Asbestos fiber release from the brake pads of overhead industrial cranes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spencer, J.W.; Plisko, M.J.; Balzer, J.L.
The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibersmore » were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranges from <0.005 to 0.011 fibers/cc (PCM), and <0.0026 to <0.0094f/cc (TEM). There were no asbestos fibers detected by the TEM method from air samples collected during the operation of the cranes.« less
Asbestos fiber release from the brake pads of overhead industrial cranes.
Spencer, J W; Plisko, M J; Balzer, J L
1999-06-01
The purpose of this evaluation was to determine the actual contribution of airborne asbestos fibers to the work environment from the operation of overhead cranes and hoists that use asbestos composition brake pads. The evaluation was conducted in a working manufacturing facility. Other potential sources of asbestos were accounted for by visual inspection and background air monitoring. An overhead crane assembly comprised of a trolley and two hoists was employed for this study. The crane was operated for two consecutive eight-hour shifts representative of a heavy-duty cycle. Forty-four personal and area air samples were collected during the assessment. Asbestos fibers were analyzed for by phase contrast (NIOSH 7400), and transmission electron (NIOSH 7402) microscopy methods. Eight-hour time-weighted average (TWA) asbestos fiber concentrations ranged from < 0.005 to 0.011 fibers/cc (PCM), and < 0.0026 to < 0.0094 f/cc (TEM). There were no asbestos fibers detected by the TEM method from air samples collected during the operation of the cranes.
Factors influencing microbial colonies in the air of operating rooms.
Fu Shaw, Ling; Chen, Ian Horng; Chen, Chii Shya; Wu, Hui Hsin; Lai, Li Shing; Chen, Yin Yin; Wang, Fu Der
2018-01-02
The operating room (OR) of the hospital is a special unit that requires a relatively clean environment. The microbial concentration of an indoor OR extrinsically influences surgical site infection rates. The aim of this study was to use active sampling methods to assess microbial colony counts in working ORs and to determine the factors affecting air contamination in a tertiary referral medical center. This study was conducted in 28 operating rooms located in a 3000-bed medical center in northern Taiwan. The microbiologic air counts were measured using an impactor air sampler from May to August 2015. Information about the procedure-related operative characteristics and surgical environment (environmental- and personnel-related factors) characteristics was collected. A total of 250 air samples were collected during surgical procedures. The overall mean number of bacterial colonies in the ORs was 78 ± 47 cfu/m 3 . The mean number of colonies was the highest for transplant surgery (123 ± 60 cfu/m 3 ), followed by pediatric surgery (115 ± 30.3 cfu/m 3 ). A total of 25 samples (10%) contained pathogens; Coagulase-negative staphylococcus (n = 12, 4.8%) was the most common pathogen. After controlling for potentially confounding factors by a multiple regression analysis, the surgical stage had the significantly highest correlation with bacterial counts (r = 0.346, p < 0.001). Otherwise, independent factors influencing bacterial counts were the type of surgery (29.85 cfu/m 3 , 95% CI 1.28-58.42, p = 0.041), site of procedure (20.19 cfu/m 3 , 95% CI 8.24-32.14, p = 0.001), number of indoor staff (4.93 cfu/m 3 , 95% CI 1.47-8.38, p = 0.005), surgical staging (36.5 cfu/m 3 , 95% CI 24.76-48.25, p < 0.001), and indoor air temperature (9.4 cfu/m 3 , 95% CI 1.61-17.18, p = 0.018). Under the well-controlled ventilation system, the mean microbial colony counts obtained by active sampling in different working ORs were low. The number of personnel and their activities critically influence the microbe concentration in the air of the OR. We suggest that ORs doing complex surgeries with more surgical personnel present should increase the frequency of air exchanges. A well-controlled ventilation system and infection control procedures related to environmental and surgical procedures are of paramount importance for reducing microbial colonies in the air.
NASA Technical Reports Server (NTRS)
Davis, R. E.; Champine, R. A.; Ehernberger, L. J.
1979-01-01
The results of 46 clear air turbulence (CAT) probing missions conducted with an extensively instrumented B-57B aircraft are summarized. Turbulence samples were obtained under diverse conditions including mountain waves, jet streams, upper level fronts and troughs, and low altitude mechanical and thermal turbulence. CAT was encouraged on 20 flights comprising 77 data runs. In all, approximately 4335 km were flown in light turbulence, 1415 km in moderate turbulence, and 255 km in severe turbulence during the program. The flight planning, operations, and turbulence forecasting aspects conducted with the B-57B aircraft are presented.
Determination of methyl bromide in air samples by headspace gas chromatography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodrow, J.E.; McChesney, M.M.; Seiber, J.N.
1988-03-01
Methyl bromide is extensively used in agriculture (4 x 10/sup 6/ kg for 1985 in California alone as a fumigant to control nematodes, weeds, and fungi in soil and insect pests in harvested grains and nuts. Given its low boiling point (3.8/sup 0/C) and high vapor pressure (approx. 1400 Torr at 20/sup 0/C), methyl bromide will readily diffuse if not rigorously contained. Methods for determining methyl bromide and other halocarbons in air vary widely. A common practice is to trap the material from air on an adsorbent, such as polymeric resins, followed by thermal desorption either directly into the analyticalmore » instrumentation or after intermediary cryofocusing. While in some cases analytical detection limits were reasonable (parts per million range), many of the published methods were labor intensive and required special handling techniques that precluded high sample throughput. They describe here a method for the sampling and analysis of airborne methyl bromide that was designed to handle large numbers of samples through automating some critical steps of the analysis. The result was a method that allowed around-the-clock operation with a minimum of operator attention. Furthermore, the method was not specific to methyl bromide and could be used to determine other halocarbons in air.« less
Airborne concentrations of volatile organic compounds in neonatal incubators.
Prazad, P; Cortes, D R; Puppala, B L; Donovan, R; Kumar, S; Gulati, A
2008-08-01
To identify and quantify airborne volatile organic compounds (VOCs) inside neonatal incubators during various modes of operation within the neonatal intensive care unit (NICU) environment. Air samples were taken from 10 unoccupied incubators in four operational settings along with ambient air samples using air sampling canisters. The samples were analyzed following EPA TO-15 using a Tekmar AutoCan interfaced to Agilent 6890 Gas Chromatograph with a 5973 Mass Spectrometer calibrated for 60 EPA TO-15 method target compounds. Non-target compounds were tentatively identified using mass spectral interpretation and with a mass spectral library created by National Institute for Standards and Technology. Two non-target compounds, 2-heptanone and n-butyl acetate, were found at elevated concentrations inside the incubators compared with ambient room air samples. Increase in temperature and addition of humidity produced further increased concentrations of these compounds. Their identities were verified by mass spectra and relative retention times using authentic standards. They were quantified using vinyl acetate and 2-hexanone as surrogate standards. The emission pattern of these two compounds and background measurements indicate that they originate inside the incubator. There is evidence that exposure to some VOCs may adversely impact the fetal and developing infants' health. Currently, as there is no definitive information available on the effects of acute or chronic low-level exposure to these compounds in neonates, future studies evaluating the health effects of neonatal exposure to these VOCs are needed.
Fritz, Brad G; Patton, Gregory W
2006-01-01
While other research has reported on the concentrations of (129)I in the environment surrounding active nuclear fuel reprocessing facilities, there is a shortage of information regarding how the concentrations change once facilities close. At the Hanford Site, the Plutonium-Uranium Extraction (PUREX) chemical separation plant was operating between 1983 and 1990, during which time (129)I concentrations in air and milk were measured. After the cessation of chemical processing, plant emissions decreased 2.5 orders of magnitude over an 8-year period. An evaluation of (129)I and (127)I concentration data in air and milk spanning the PUREX operation and post-closure period was conducted to compare the changes in environmental levels. Measured concentrations over the monitoring period were below the levels that could result in a potential annual human dose greater than 1 mSv. There was a measurable difference in the measured air concentrations of (129)I at different distances from the source, indicating a distinct Hanford fingerprint. Correlations between stack emissions of (129)I and concentrations in air and milk indicate that atmospheric emissions were the major source of (129)I measured in environmental samples. The measured concentrations during PUREX operations were similar to observations made around a fuel reprocessing plant in Germany. After the PUREX Plant stopped operating, (129)I concentration measurements made upwind of Hanford were similar to the results from Seville, Spain.
NASA Technical Reports Server (NTRS)
Martini, W. R.
1981-01-01
A series of computer programs are presented with full documentation which simulate the transient behavior of a modern 4 cylinder Siemens arrangement Stirling engine with burner and air preheater. Cold start, cranking, idling, acceleration through 3 gear changes and steady speed operation are simulated. Sample results and complete operating instructions are given. A full source code listing of all programs are included.
Convair F-106B Delta Dart with Air Sampling Equipment
1974-04-21
The National Aeronautics and Space Administration (NASA) Lewis Research Center’s Convair F-106B Delta Dart equipped with air sampling equipment in the mid-1970s. NASA Lewis created and managed the Global Air Sampling Program (GASP) in 1972 in partnership with several airline companies. NASA researchers used the airliners’ Boeing 747 aircraft to gather air samples to determine the amount of pollution present in the stratosphere. Private companies developed the air sampling equipment for the GASP program, and Lewis created a particle collector. The collector was flight tested on NASA Lewis’ F-106B in the summer of 1973. The sampling equipment was automatically operated once the proper altitude was achieved. The sampling instruments collected dust particles in the air so their chemical composition could be analyzed. The equipment analyzed one second’s worth of data at a time. The researchers also monitored carbon monoxide, monozide, ozone, and water vapor. The 747 flights began in December 1974 and soon included four airlines flying routes all over the globe. The F-106B augmented the airline data with sampling of its own, seen here. It gathered samples throughout this period from locations such as New Mexico, Texas, Michigan, and Ohio. In July 1977 the F-106B flew eight GASP flights in nine days over Alaska to supplement the earlier data gathered by the airlines.
Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
TEMPLETON, A.M.
2000-03-06
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less
Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
TEMPLETON, A.M.
2000-01-31
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less
Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
TEMPLETON, A.M.
2000-04-10
This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissionsmore » Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.« less
Hariri, Azian; Mohamad Noor, Noraishah; Paiman, Nuur Azreen; Ahmad Zaidi, Ahmad Mujahid; Zainal Bakri, Siti Farhana
2017-09-22
Welding operations are rarely conducted in an air-conditioned room. However, a company would set its welding operations in an air-conditioned room to maintain the humidity level needed to reduce hydrogen cracks in the specimen being welded. This study intended to assess the exposure to metal elements in the welders' breathing zone and toenail samples. Heavy metal concentration was analysed using inductively coupled plasma mass spectrometry. The lung function test was also conducted and analysed using statistical approaches. Chromium and manganese concentrations in the breathing zone exceeded the permissible exposure limit stipulated by Malaysian regulations. A similar trend was obtained in the concentration of heavy metals in the breathing zone air sampling and in the welders' toenails. Although there was no statistically significant decrease in the lung function of welders, it is suggested that exposure control through engineering and administrative approaches should be considered for workplace safety and health improvement.
Shah, Sachin D.; Quigley, Sean M.
2005-01-01
Air Force Plant 4 (AFP4) and adjacent Naval Air Station-Joint Reserve Base (NAS-JRB) at Fort Worth, Tex., constitute a government-owned, contractor-operated (GOCO) facility that has been in operation since 1942. Contaminants from the facility, primarily volatile organic compounds (VOCs) and metals, have entered the groundwater-flow system through leakage from waste-disposal sites (landfills and pits) and from manufacturing processes (U.S. Air Force, Aeronautical Systems Center, 1995). The U.S. Geological Survey (USGS), in cooperation with the U.S. Air Force (USAF), Aeronautical Systems Center, Environmental Management Directorate (ASC/ENVR), developed a comprehensive database (or geodatabase) of temporal and spatial environmental information associated with the geology, hydrology, and water quality at AFP4 and NAS-JRB. The database of this report provides information about the AFP4 and NAS-JRB study area including sample location names, identification numbers, locations, historical dates, and various measured hydrologic data. This database does not include every sample location at the site, but is limited to an aggregation of selected digital and hardcopy data of the USAF, USGS, and various consultants who have previously or are currently working at the site.
Evaluation of the Air Quality Monitor's Performance on the International Space Station
NASA Technical Reports Server (NTRS)
Limero, Thomas; Reese, Eric; Ballard, Ken; Durham, Tamara
2010-01-01
The Air Quality Monitor (AQM) was flown to the International Space Station (ISS) as an experiment to evaluate its potential to replace the aging Volatile Organic Analyzer (VOA), which ceased operations in August 2009. The AQM (Figure 1) is a small gas chromatography/differential mobility spectrometer (GC/DMS) manufactured by Sionex. Data was presented at last year s ISIMS conference that detailed the preparation of the AQM for flight, including instrument calibration. Furthermore, initial AQM data was compared to VOA results from simultaneous runs of the two instruments. Although comparison with VOA data provided a measure of confidence in the AQM performance, it is the comparison with results from simultaneously acquired air samples (grab sample containers-GSCs) that will define the success (or failure) of the AQM performance. This paper will update the progress in the AQM investigation by comparing AQM data to results from the analyses of GSC samples, returned from ISS. Additionally, a couple of example will illustrate the AQM s ability to detect disruptions in the spacecraft s air quality. Discussion will also focus upon a few unexpected issues that have arisen and how these will be a addressed in the final operational unit now being built.
Optimizing integrated airport surface and terminal airspace operations under uncertainty
NASA Astrophysics Data System (ADS)
Bosson, Christabelle S.
In airports and surrounding terminal airspaces, the integration of surface, arrival and departure scheduling and routing have the potential to improve the operations efficiency. Moreover, because both the airport surface and the terminal airspace are often altered by random perturbations, the consideration of uncertainty in flight schedules is crucial to improve the design of robust flight schedules. Previous research mainly focused on independently solving arrival scheduling problems, departure scheduling problems and surface management scheduling problems and most of the developed models are deterministic. This dissertation presents an alternate method to model the integrated operations by using a machine job-shop scheduling formulation. A multistage stochastic programming approach is chosen to formulate the problem in the presence of uncertainty and candidate solutions are obtained by solving sample average approximation problems with finite sample size. The developed mixed-integer-linear-programming algorithm-based scheduler is capable of computing optimal aircraft schedules and routings that reflect the integration of air and ground operations. The assembled methodology is applied to a Los Angeles case study. To show the benefits of integrated operations over First-Come-First-Served, a preliminary proof-of-concept is conducted for a set of fourteen aircraft evolving under deterministic conditions in a model of the Los Angeles International Airport surface and surrounding terminal areas. Using historical data, a representative 30-minute traffic schedule and aircraft mix scenario is constructed. The results of the Los Angeles application show that the integration of air and ground operations and the use of a time-based separation strategy enable both significant surface and air time savings. The solution computed by the optimization provides a more efficient routing and scheduling than the First-Come-First-Served solution. Additionally, a data driven analysis is performed for the Los Angeles environment and probabilistic distributions of pertinent uncertainty sources are obtained. A sensitivity analysis is then carried out to assess the methodology performance and find optimal sampling parameters. Finally, simulations of increasing traffic density in the presence of uncertainty are conducted first for integrated arrivals and departures, then for integrated surface and air operations. To compare the optimization results and show the benefits of integrated operations, two aircraft separation methods are implemented that offer different routing options. The simulations of integrated air operations and the simulations of integrated air and surface operations demonstrate that significant traveling time savings, both total and individual surface and air times, can be obtained when more direct routes are allowed to be traveled even in the presence of uncertainty. The resulting routings induce however extra take off delay for departing flights. As a consequence, some flights cannot meet their initial assigned runway slot which engenders runway position shifting when comparing resulting runway sequences computed under both deterministic and stochastic conditions. The optimization is able to compute an optimal runway schedule that represents an optimal balance between total schedule delays and total travel times.
Brounshtein, A. M. [Main Geophysical Observatory, St. Petersburg, Russia; Shaskov, A. A. [Main Geophysical Observatory, St. Petersburg, Russia; Paramonova, N. N. [Main Geophysical Observatory, St. Petersburg, Russia; Privalov, V. I. [Main Geophysical Observatory, St. Petersburg, Russia; Starodubtsev, Y. A. [Main Geophysical Observatory, St. Petersburg, Russia
1997-01-01
Air samples were collected from five sites in the Main Geophysical Observatory air sampling network to monitor the atmospheric CO2 from 1983 - 1993. Airwas collected generally four times per month in pairs of 1.5-L stainless steel electropolished flasks with one greaseless stainless steel stopcock. Sampling was performed by opening the stopcock of the flasks, which have been evacuated at the central laboratory at the Main Geophysical Observatory (MGO). The air was not dried during sample collection. Attempts were made to obtain samples when the wind speed was >5 m/s and the wind direction corresponded to the predetermined "clean air" sector. The period of record at Bering Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Bering Island rose from approximately 346 parts per million by volume (ppmv) in 1986 to 362.6 ppmv in 1993. Measurements from this station are considered indicative of maritime air masses. The period of record at Kotelny Island is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Kotelny Island rose from 356.08 parts per million by volume (ppmv) in 1988 to 358.8 ppmv in 1993. Because Kotelny Island is the northernmost Russian sampling site, measurements from this site serve as a useful comparison to other northern sites (e.g., Alert, Northwest Territories). In late 1989, air sampling began at the Russian site of Kyzylcha, located in the Republic of Uzbekistan. Unfortunately, the desert site at Kyzylcha has been out of operation since mid-1991 due to financial difficulties in Russia. The annual mean value of 359.02 parts per million by volume (ppmv) for 1990, the lone full year of operation, is higher than measurements from other monitoring programs at this latitude [e.g., Niwot Ridge (354.7 ppmv in 1990) and Tae-ahn Peninsula]. Station "C," an open ocean site, in the North Atlantic, east of Greenland, was established in 1968 and was operated in cooperation with NOAA's National Weather Service through 1973. The Main Geophysical Observatory collected flask samples at the site from January 1983 through October 1990. The yearly mean atmospheric CO concentration at Station "C" rose from 348.15 parts per million by volume (ppmv) in 1985 to 354.33 ppmv in 1989. The period of record at Teriberka Station is too short to identify any long-term trends in atmospheric CO2 concentrations; however, the yearly mean atmospheric CO2 concentration at Teriberka Station rose from 354.8 parts per million by volume (ppmv) in 1989 to 358.7 ppmv in 1993.
The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...
Atmospheric Sampling on Ascension Island Using Multirotor UAVs.
Greatwood, Colin; Richardson, Thomas S; Freer, Jim; Thomas, Rick M; MacKenzie, A Rob; Brownlow, Rebecca; Lowry, David; Fisher, Rebecca E; Nisbet, Euan G
2017-05-23
As part of an NERC-funded project investigating the southern methane anomaly, a team drawn from the Universities of Bristol, Birmingham and Royal Holloway flew small unmanned multirotors from Ascension Island for the purposes of atmospheric sampling. The objective of these flights was to collect air samples from below, within and above a persistent atmospheric feature, the Trade Wind Inversion, in order to characterise methane concentrations and their isotopic composition. These parameters allow the methane in the different air masses to be tied to different source locations, which can be further analysed using back trajectory atmospheric computer modelling. This paper describes the campaigns as a whole including the design of the bespoke eight rotor aircraft and the operational requirements that were needed in order to collect targeted multiple air samples up to 2.5 km above the ground level in under 20 min of flight time. Key features of the system described include real-time feedback of temperature and humidity, as well as system health data. This enabled detailed targeting of the air sampling design to be realised and planned during the flight mission on the downward leg, a capability that is invaluable in the presence of uncertainty in the pre-flight meteorological data. Environmental considerations are also outlined together with the flight plans that were created in order to rapidly fly vertical transects of the atmosphere whilst encountering changing wind conditions. Two sampling campaigns were carried out in September 2014 and July 2015 with over one hundred high altitude sampling missions. Lessons learned are given throughout, including those associated with operating in the testing environment encountered on Ascension Island.
40 CFR 61.33 - Stack sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Stack sampling. 61.33 Section 61.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Unless a waiver of emission testing is obtained under § 61.13, each owner or operator...
40 CFR 61.33 - Stack sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Stack sampling. 61.33 Section 61.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... sampling. (a) Unless a waiver of emission testing is obtained under § 61.13, each owner or operator...
Air Monitoring Data for BP Spill/Deepwater Horizon
The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following the explosion and sinking of the Deepwater Horizon oil rig, a sea-floor oil gusher flowed for 87 days, until it was capped on 15 July 2010.In response to the BP oil spill, EPA sampled air, water, sediment, and waste generated by the cleanup operations.
von Vogelsang, A-C; Förander, P; Arvidsson, M; Löwenhielm, P
2018-03-24
Surgical site infections (SSIs) after neurosurgery are potentially life-threatening and entail great costs. SSIs may occur from airborne bacteria in the operating room, and ultraclean air is desired during infection-prone cleaning procedures. Door openings and the number of persons present in the operating room affect the air quality. Mobile laminar airflow (MLAF) units, with horizontal laminar airflow, have previously been shown to reduce airborne bacterial contamination. To assess the effect of MLAF units on airborne bacterial contamination during neurosurgical procedures. In a quasi-experimental design, bacteria-carrying particles (colony-forming units: cfu) during neurosurgical procedures were measured with active air-sampling in operating rooms with conventional turbulent ventilation, and with additional MLAF units. The MLAF units were shifted between operating rooms monthly. Colony-forming unit count and bacterial species detection were conducted after incubation. Data was collected for a period of 18 months. A total of 233 samples were collected during 45 neurosurgical procedures. The use of MLAF units significantly reduced the numbers of cfu in the surgical site area (P < 0.001) and above the instrument table (P < 0.001). Logistic regression showed that the only significant predictor affecting cfu count was the use of MLAF units (odds ratio: 41.6; 95% confidence interval: 11.3-152.8; P < 0.001). The most frequently detected bacteria were coagulase-negative staphylococci. MLAF successfully reduces cfu during neurosurgery to ultraclean air levels. MLAF units are valuable when the main operating room ventilation system is unable to produce ultraclean air in infection-prone clean neurosurgery. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Rodgers, John C.; Wasiolek, Piotr T.; Schery, Stephen D.; Alcantara, Raul E.
1999-01-01
The need for a continuous air monitor capable of quick and accurate measurements of airborne radioactivity in close proximity to the work environment during waste management, site restoration, and D&D operations led to the Los Alamos National Laboratory development of an environmental continuous air monitor (ECAM). Monitoring the hostile work environment of waste recovery, for example, presents unique challenges for detector design for detectors previously used for the clean room conditions of the typical plutonium laboratory. The environmental and atmospheric conditions (dust, high wind, etc.) influence aerosol particle penetration into the ECAM sampling head as well as the build-up of deposits on the ECAM filter.
40 CFR 86.121-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... used operating range with propane in air calibration gases (either methanol or methane in air as... response factor to methane. When the FID analyzer is to be used for the analysis of gasoline, diesel, methanol, ethanol, liquefied petroleum gas, and natural gas-fueled vehicle hydrocarbon samples, the methane...
40 CFR 86.121-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... used operating range with propane in air calibration gases (either methanol or methane in air as... response factor to methane. When the FID analyzer is to be used for the analysis of gasoline, diesel, methanol, ethanol, liquefied petroleum gas, and natural gas-fueled vehicle hydrocarbon samples, the methane...
40 CFR 86.121-90 - Hydrocarbon analyzer calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... used operating range with propane in air calibration gases (either methanol or methane in air as... response factor to methane. When the FID analyzer is to be used for the analysis of gasoline, diesel, methanol, ethanol, liquefied petroleum gas, and natural gas-fueled vehicle hydrocarbon samples, the methane...
Agodi, A; Auxilia, F; Barchitta, M; Cristina, M L; D'Alessandro, D; Mura, I; Nobile, M; Pasquarella, C
2015-07-01
Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique. To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery. Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded. In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤ 2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P < 0.001). In addition, correlation was found between active and passive sampling (P < 0.001). These findings challenge the belief that unidirectional systems always provide acceptable airborne bacterial counts. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Journal Article: the National Dioxin Air Monitoring Network ...
In June, 1998, the U.S. EPA established the National Dioxin Air Monitoring Network (NDAMN). The primary goal of NDAMN is determine the temporal and geographical variability of atmospheric CDDs, CDFs, and coplanar PCBs at rural and nonimpacted locations throughout the United States. Currently operating at 32 sampling stations, NDAMN has three primary purposes: (1) to determine the atmospheric levels and occurrences of dioxin-like compounds in rural and agricultural areas where livestock, poultry and animal feed crops are grown; (2) to provide measurements of atmospheric levels of dioxin-like compounds in different geographic regions of the U.S.; and (3) to provide information regarding the long-range transport of dioxin-like compounds in air over the U.S. At Dioxin 2000, we reported on the preliminary results of monitoring at 9 rural locations from June 1998 through June 1999. By the end of 1999, NDAMN had expanded to 21 sampling stations. Then, at Dioxin 2001, we reported the results of the first 18 months of operation of NDAMN at 15 rural and 6 National Park stations in the United States. The following is intended to be an update to this national monitoring effort. We are reporting the air monitoring results of 17 rural and 8 National Park NDAMN stations operational over 4 sampling moments during calendar year 2000. Two stations located in suburban Washington DC and San Francisco, CA are more urban in character and serve as an indicator of CDD/F and cop
Andersson, Annette Erichsen; Bergh, Ingrid; Karlsson, Jón; Eriksson, Bengt I; Nilsson, Kerstin
2012-10-01
Understanding the protective potential of operating room (OR) ventilation under different conditions is crucial to optimizing the surgical environment. This study investigated the air quality, expressed as colony-forming units (CFU)/m(3), during orthopedic trauma surgery in a displacement-ventilated OR; explored how traffic flow and the number of persons present in the OR affects the air contamination rate in the vicinity of surgical wounds; and identified reasons for door openings in the OR. Data collection, consisting of active air sampling and observations, was performed during 30 orthopedic procedures. In 52 of the 91 air samples collected (57%), the CFU/m(3) values exceeded the recommended level of <10 CFU/m(3). In addition, the data showed a strongly positive correlation between the total CFU/m(3) per operation and total traffic flow per operation (r = 0.74; P = .001; n = 24), after controlling for duration of surgery. A weaker, yet still positive correlation between CFU/m(3) and the number of persons present in the OR (r = 0.22; P = .04; n = 82) was also found. Traffic flow, number of persons present, and duration of surgery explained 68% of the variance in total CFU/m(3) (P = .001). Traffic flow has a strong negative impact on the OR environment. The results of this study support interventions aimed at preventing surgical site infections by reducing traffic flow in the OR. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Trace anesthetic vapors in hospital operating-room environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi-Lao, A.T.
1981-05-01
This study investigated concentrations of halothane anesthetic vapors in the operating rooms of two hospitals in the Ottawa, Ontario, Canada, area. Air samples, taken by active charcoal tubes and dosimeter badges, were analyzed by a gas chromatographic technique. Readings of 71 samples taken from hospital A and 65 samples from hospital B ranged from 1.0 to 29.4 parts per billion (ppb) for the active period and 0.1 to 3.8 ppb for the inactive period. All samples showed trace concentrations of halothane, but were well below the recommended maximal level.
The purpose of this SOP is to describe the acid digestion of soil, house dust, air filter, and surface or dermal wipe samples for analysis using inductively coupled plasma atomic emissions spectrometry (ICP-AES) and/or graphite furnace atomic absorption spectrometry (GFAAS) or fl...
Apparatus and process for collection of gas and vapor samples
Jackson, Dennis G [Augusta, GA; Peterson, Kurt D [Aiken, SC; Riha, Brian D [Augusta, GA
2008-04-01
A gas sampling apparatus and process is provided in which a standard crimping tool is modified by an attached collar. The collar permits operation of the crimping tool while also facilitating the introduction of a supply of gas to be introduced into a storage vial. The introduced gas supply is used to purge ambient air from a collection chamber and an interior of the sample vial. Upon completion of the purging operation, the vial is sealed using the crimping tool.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trott, Donna M.; LePage, Jane; Hebert, Vincent
A regional air assessment was performed to characterize volatile natural isothiocyanate (NITC) compounds in air during soil incorporation of mustard cover crops in Washington State. Field air sampling and analytical methods were developed specific to three NITCs known to be present in air at appreciable concentrations during/after field incorporation. The maximum observed concentrations in air for the allyl, benzyl, and phenethyl isothiocyanates were respectively 188, 6.1, and 0.7 lg m-3 during mustard incorporation. Based on limited inhalation toxicity information, airborne NITC concentrations did not appear to pose an acute human inhalation exposure concern to field operators and bystanders.
Sagi, H C; DiPasquale, Thomas; Sanders, Roy; Herscovici, Dolfi
2002-01-01
To determine if the exhaust from surgical compressed-air power tools contains bacteria and if the exhaust leads to contamination of sterile surfaces. Bacteriologic study of orthopaedic power tools. Level I trauma center operative theater. None. Part I. Exhaust from two sterile compact air drills was sampled directly at the exhaust port. Part II. Exhaust from the drills was directed at sterile agar plates from varying distances. The agar plates represented sterile surfaces within the operative field. Part III. Control cultures. A battery-powered drill was operated over open agar plates in similar fashion as the compressed-air drills. Agar plates left open in the operative theater served as controls to rule out atmospheric contamination. Random cultures were taken from agar plates, gloves, drills, and hoses. Incidence of positive cultures. In Part I, all filters from both compressed-air drill exhausts were culture negative ( = 0.008). In Part II, the incidence of positive cultures for air drills number one and number two was 73% and 82%, respectively. The most commonly encountered organisms were, coagulase-negative Staphylococcus, and Micrococcus species. All control cultures from agar plates, battery-powered drill, gloves, and hoses were negative ( < 0.01). Exhaust from compressed-air power tools in orthopaedic surgery may contribute to the dissemination of bacteria onto the surgical field. We do not recommend the use of compressed-air power tools that do not have a contained exhaust.
Advisory Algorithm for Scheduling Open Sectors, Operating Positions, and Workstations
NASA Technical Reports Server (NTRS)
Bloem, Michael; Drew, Michael; Lai, Chok Fung; Bilimoria, Karl D.
2012-01-01
Air traffic controller supervisors configure available sector, operating position, and work-station resources to safely and efficiently control air traffic in a region of airspace. In this paper, an algorithm for assisting supervisors with this task is described and demonstrated on two sample problem instances. The algorithm produces configuration schedule advisories that minimize a cost. The cost is a weighted sum of two competing costs: one penalizing mismatches between configurations and predicted air traffic demand and another penalizing the effort associated with changing configurations. The problem considered by the algorithm is a shortest path problem that is solved with a dynamic programming value iteration algorithm. The cost function contains numerous parameters. Default values for most of these are suggested based on descriptions of air traffic control procedures and subject-matter expert feedback. The parameter determining the relative importance of the two competing costs is tuned by comparing historical configurations with corresponding algorithm advisories. Two sample problem instances for which appropriate configuration advisories are obvious were designed to illustrate characteristics of the algorithm. Results demonstrate how the algorithm suggests advisories that appropriately utilize changes in airspace configurations and changes in the number of operating positions allocated to each open sector. The results also demonstrate how the advisories suggest appropriate times for configuration changes.
The purpose of this SOP is to describe the methods used to collect indoor and outdoor air samples for the determination of selected volatile organic compounds (VOC's) using a pump to draw air through a Carbotrap Sampler. Volatile organic compounds (VOCs) present in the air are p...
Use Of The Operational Air Quality Monitor (AQM) For In-Flight Water Testing Project
NASA Technical Reports Server (NTRS)
Macatangay, Ariel
2014-01-01
A primary requirement for manned spaceflight is Environmental Health which ensures air and water contaminants, acoustic profiles, microbial flora, and radiation exposures within the cabin are maintained to levels needed for crew health and for vehicle system functionality. The reliance on ground analyses of returned samples is a limitation in the current environmental monitoring strategy that will prevent future Exploration missions beyond low-Earth orbit. This proposal attempts to address this shortcoming by advancing in-flight analyses of water and air. Ground analysis of in-flight, air and water samples typically employ vapor-phase analysis by gas chromatography-mass spectrometry (GC-MS) to identify and quantify organic compounds present in the samples. We envision the use of newly-developed direct ionization approaches as the most viable avenue leading towards an integrated analytical platform for the monitoring of water, air, and, potentially bio-samples in the cabin environment. Development of an in-flight instrument capable of analyzing air and water samples would be the logical next step to meeting the environmental monitoring needs of Exploration missions. Currently, the Air Quality Monitor (AQM) on-board ISS provides this specific information for a number of target compounds in the air. However, there is a significant subset of common target compounds between air and water. Naturally, the following question arises, "Can the AQM be used for both air and water quality monitoring?" Previous directorate-level IR&D funding led to the development of a water sample introduction method for mass spectrometry using electrothermal vaporization (ETV). This project will focus on the integration of the ETV with a ground-based AQM. The capabilities of this integrated platform will be evaluated using a subset of toxicologically important compounds.
Hazrati, Sadegh; Harrad, Stuart
2007-03-01
PUF disk passive air samplers are increasingly employed for monitoring of POPs in ambient air. In order to utilize them as quantitative sampling devices, a calibration experiment was conducted. Time integrated indoor air concentrations of PCBs and PBDEs were obtained from a low volume air sampler operated over a 50 d period alongside the PUF disk samplers in the same office microenvironment. Passive sampling rates for the fully-sheltered sampler design employed in our research were determined for the 51 PCB and 7 PBDE congeners detected in all calibration samples. These values varied from 0.57 to 1.55 m3 d(-1) for individual PCBs and from 1.1 to 1.9 m3 d(-1) for PBDEs. These values are appreciably lower than those reported elsewhere for different PUF disk sampler designs (e.g. partially sheltered) employed under different conditions (e.g. in outdoor air), and derived using different calibration experiment configurations. This suggests that sampling rates derived for a specific sampler configuration deployed under specific environmental conditions, should not be extrapolated to different sampler configurations. Furthermore, our observation of variable congener-specific sampling rates (consistent with other studies), implies that more research is required in order to understand fully the factors that influence sampling rates. Analysis of wipe samples taken from the inside of the sampler housing, revealed evidence that the housing surface scavenges particle bound PBDEs.
Atmospheric Sampling on Ascension Island Using Multirotor UAVs
Greatwood, Colin; Richardson, Thomas S.; Freer, Jim; Thomas, Rick M.; MacKenzie, A. Rob; Brownlow, Rebecca; Lowry, David; Fisher, Rebecca E.; Nisbet, Euan G.
2017-01-01
As part of an NERC-funded project investigating the southern methane anomaly, a team drawn from the Universities of Bristol, Birmingham and Royal Holloway flew small unmanned multirotors from Ascension Island for the purposes of atmospheric sampling. The objective of these flights was to collect air samples from below, within and above a persistent atmospheric feature, the Trade Wind Inversion, in order to characterise methane concentrations and their isotopic composition. These parameters allow the methane in the different air masses to be tied to different source locations, which can be further analysed using back trajectory atmospheric computer modelling. This paper describes the campaigns as a whole including the design of the bespoke eight rotor aircraft and the operational requirements that were needed in order to collect targeted multiple air samples up to 2.5 km above the ground level in under 20 min of flight time. Key features of the system described include real-time feedback of temperature and humidity, as well as system health data. This enabled detailed targeting of the air sampling design to be realised and planned during the flight mission on the downward leg, a capability that is invaluable in the presence of uncertainty in the pre-flight meteorological data. Environmental considerations are also outlined together with the flight plans that were created in order to rapidly fly vertical transects of the atmosphere whilst encountering changing wind conditions. Two sampling campaigns were carried out in September 2014 and July 2015 with over one hundred high altitude sampling missions. Lessons learned are given throughout, including those associated with operating in the testing environment encountered on Ascension Island. PMID:28545231
SNIFFER: An aerial platform for the plume phase of a nuclear emergency
NASA Astrophysics Data System (ADS)
Castelluccio, D. M.; Cisbani, E.; Frullani, S.
2012-04-01
When a nuclear or radiological accident results in a release of a radioactive plume, AGS (Aerial Gamma Spectrometry) systems used in many countries, equipped with passive detectors, can help in giving quantitative assessment on the radiological situation (land surface contamination level) only when the air contamination due to the passage of the travelling plume has become negligible. To overcome this limitation, the Italian Institute of Health has developed and implemented a multi purpose air sampling system based on a fixed wing aircraft, for time-effective, large areas radiological surveillance (to face radiological emergency and to support homeland security). A fixed wing aircraft (Sky Arrow 650) with the front part of the fuselage properly adapted to house the detection equipment has been equipped with a compact air sampling line where the isokinetic sampling is dynamically maintained. Aerosol is collected on a Teflon® filter positioned along the line and hosted on a rotating 4-filters disk. A complex of detectors allows radionuclide identification in the collected aerosol samples. A correlated analysis of these two detectors data allows a quantitative measurement of air as well as ground surface concentration of gamma emitting radioisotopes. Environmental sensors and a GPS receiver support the characterization of the sampling conditions and the temporal and geolocation of the acquired data. Acquisition and control system based on compact electronics and real time software that operate the sampling line actuators, guarantee the dynamical isokinetic condition, and acquire the detectors and sensor data. The system is also equipped with other sampling lines to provide information on the concentration of other chemical pollutants. Operative flights have been carried out in the last years, and performances and results are presented.
40 CFR 86.523-78 - Oxides of nitrogen analyzer calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... analyzer to optimize performance. (2) Zero the oxides of nitrogen analyzer with zero grade air or zero... samples. Proceed as follows: (1) Adjust analyzer to optimize performance. (2) Zero the oxides of nitrogen analyzer with zero grade air or zero grade nitrogen. (3) Calibrate on each normally used operating range...
Air sampling unit for breath analyzers
NASA Astrophysics Data System (ADS)
Szabra, Dariusz; Prokopiuk, Artur; Mikołajczyk, Janusz; Ligor, Tomasz; Buszewski, Bogusław; Bielecki, Zbigniew
2017-11-01
The paper presents a portable breath sampling unit (BSU) for human breath analyzers. The developed unit can be used to probe air from the upper airway and alveolar for clinical and science studies. The BSU is able to operate as a patient interface device for most types of breath analyzers. Its main task is to separate and to collect the selected phases of the exhaled air. To monitor the so-called I, II, or III phase and to identify the airflow from the upper and lower parts of the human respiratory system, the unit performs measurements of the exhaled CO2 (ECO2) in the concentration range of 0%-20% (0-150 mm Hg). It can work in both on-line and off-line modes according to American Thoracic Society/European Respiratory Society standards. A Tedlar bag with a volume of 5 dm3 is mounted as a BSU sample container. This volume allows us to collect ca. 1-25 selected breath phases. At the user panel, each step of the unit operation is visualized by LED indicators. This helps us to regulate the natural breathing cycle of the patient. There is also an operator's panel to ensure monitoring and configuration setup of the unit parameters. The operation of the breath sampling unit was preliminarily verified using the gas chromatography/mass spectrometry (GC/MS) laboratory setup. At this setup, volatile organic compounds were extracted by solid phase microextraction. The tests were performed by the comparison of GC/MS signals from both exhaled nitric oxide and isoprene analyses for three breath phases. The functionality of the unit was proven because there was an observed increase in the signal level in the case of the III phase (approximately 40%). The described work made it possible to construct a prototype of a very efficient breath sampling unit dedicated to breath sample analyzers.
What is the optimal management of an intra-operative air leak in a colorectal anastomosis?
Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R
2018-02-01
An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.
NASA Technical Reports Server (NTRS)
Anderson, O. L.; Chiappetta, L. M.; Edwards, D. E.; Mcvey, J. B.
1982-01-01
A user's manual describing the operation of three computer codes (ADD code, PTRAK code, and VAPDIF code) is presented. The general features of the computer codes, the input/output formats, run streams, and sample input cases are described.
Raggi, Alessandra; Sanna, Tiziana; Mazzetti, Magda; Orsi, Alessandra; Zanni, Angela; Farruggia, Patrizia
2017-01-01
The microbiological contamination of operating theatres and the lack of adherence to best practices by surgical staff represent some of the factors affecting Surgical Site Infections (SSIs). The aim of the present study was to assess the microbiological quality of operating settings and the staff compliance to the SSI evidence-based control measures. Ten operating rooms were examined for microbiological contamination of air and surfaces, after cleaning procedures, in “at rest” conditions. Furthermore, 10 surgical operations were monitored to assess staff compliance to the recommended practices. None of the air samples exceeded microbiological reference standards and only six of the 200 surface samples (3.0%) were slightly above recommended levels. Potentially pathogenic bacteria and moulds were never detected. Staff compliance to best practices varied depending on the type of behaviour investigated and the role of the operator. The major not compliant behaviours were: pre-operative skin antisepsis, crowding of the operating room and hand hygiene of the anaesthetist. The good environmental microbiological quality observed is indicative of the efficacy of the cleaning-sanitization procedures adopted. The major critical point was staff compliance to recommended practices. Awareness campaigns are therefore necessary, aimed at improving the organisation of work so as to facilitate compliance to operative protocols. PMID:29283367
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2013 CFR
2013-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2011 CFR
2011-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2014 CFR
2014-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
40 CFR 61.107 - Emission determination.
Code of Federal Regulations, 2012 CFR
2012-07-01
... shall be made. For relatively constant flow rates only periodic measurements are necessary. (2... operation. Periodic sampling (grab samples) may be used only with EPA's prior approval. Such approval may be... potential to release radionuclides into the air, periodic confirmatory measurements should be made to verify...
De Filippis, Patrizia; Spinaci, Anna; Coia, Maura; Maggi, Oriana; Panà, Augusto
2003-01-01
The microbiological quality of the air indoor is influenced from various factors and one of the most important is represented from the maintenance of the conditioning systems. In this study it has been estimated the effectiveness of an intervention of cleaning and maintenance on the systems of conditioning of an university building executing sampling before and after such intervention. The two results were confronted and it is observed as the maintenance of the air conditioners has influenced on the quality of the air indoor.
RECOMMENDED OPERATING PROCEDURE NO. 45: ANALYSIS OF NITROUS OXIDE FROM COMBUSTION SOURCES
The recommended operating procedure (ROP) has been prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). he procedure applies to the measurement of nitrous oxide (N2O) in dry gas samples extracted from gas streams where...
The report is a recommended operating procedure (ROP) prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). he described method is applicable to the continuous measurement of total hydrocarbons (THCs), also known as tot...
The report gives results of a project, in support of the intergared Air Cancer Project (IACP), to provide data on the specific effects of appliance type and operating variables on woodstove emissions. samples of particulate material and volatile organic compounds (VOCs) were coll...
NASA Technical Reports Server (NTRS)
Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Minton, John M.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.
2014-01-01
Real-time environmental monitoring on ISS is necessary to provide data in a timely fashion and to help ensure astronaut health. Current real-time water TOC monitoring provides high-quality trending information, but compound-specific data is needed. The combination of ETV with the AQM showed that compounds of interest could be liberated from water and analyzed in the same manner as air sampling. Calibration of the AQM using water samples allowed for the quantitative analysis of ISS archival samples. Some calibration issues remain, but the excellent accuracy of DMSD indicates that ETV holds promise for as a sample introduction method for water analysis in spaceflight.
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
40 CFR 61.93 - Emission monitoring and test procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... or frequent flow rate measurements shall be made. For relatively constant flow rates only periodic... applicable to batch processes when the unit is in operation. Periodic sampling (grab samples) may be used... have a potential to release radionuclides into the air, periodic confirmatory measurements shall be...
The objective of this procedure is to collect representative samples of volatile organic compound (VOC) contaminants present in indoor and outdoor environments using multisorbent samplers, and to subsequently analyze the concentration of VOCs, as selected by EPA.
Screening portal, system and method of using same
Linker, Kevin L.; Hunter, John A.; Brusseau, Charles A.
2013-04-30
A portal, system and method for screening an object for a target substance is provided. The portal includes an inflatable bladder expandable to form a test space for receiving the object and a plurality of nozzles positioned about the inflatable bladder. The nozzles are in fluid communication with a fluid source for directing air over the object whereby samples are removed from the object for examination. A collector is operatively connected to the inflatable bladder for collecting the samples removed from the object. A detector is operatively connected to the collector for examining the removed samples for the presence of the target substance. At least one preconcentrator may be operatively connected to the collector for concentrating the samples collected thereby.
U.S. EPA response to the Fukushima Daiichi Nuclear Power Plant accident.
Tupin, Edward A; Boyd, Michael A; Mosser, Jennifer E; Wieder, Jessica S
2012-05-01
During the spring of 2011, the U.S. Environmental Protection Agency (EPA) used its national radiation monitoring and sampling system, RadNet, to detect, identify, and inform the public about radioactive material in the United States resulting from Japan's Fukushima Daiichi Nuclear Power Plant release. The RadNet system monitors ambient air, drinking water, precipitation, and pasteurized milk for radionuclides. To supplement its existing stationary (fixed) continuous air monitoring system, EPA deployed additional air monitors to Saipan, Guam, and locations in the western United States. The Agency also accelerated the regular quarterly sampling of milk and drinking water and collected an additional round of samples. For two months, staff located at EPA's Headquarters Emergency Operations Center, west coast regional offices, and National Air and Radiation Environmental Lab worked seven days a week to handle the increased radiochemical sample analysis from air filters, precipitation, drinking water, and milk; provide interagency scientific input; and answer press and public inquiries. EPA's data was consistent with what was expected from the Fukushima Daiichi Nuclear Power Plant release. The levels of radioactivity were so low that the readings from the near-real-time RadNet air monitors stayed within normal background ranges. Detailed sample analyses were needed to identify the radionuclides associated with the release. Starting at the end of April and continuing through May 2011, levels of radioactive material decreased as expected.
2009-01-01
the rotating impactors were measured via spectroscopy and microscopy. The rotary impactors were colocated with an isokinetic air sampler for a total...diameter, and the 90% diameter (DV10 and DV90; ASTM 2004). For each replication, an isokinetic air sampler and rotary sampler operated simultaneously in the...working area of the dispersion tunnel. The isokinetic sampler (StaplexH Model TFIA High Volume Air Sampler, The Staplex Company, Brooklyn, NY) was
This abstract is included for completeness of documentation, but this SOP was not used in the study.
The purpose of this SOP is to describe the procedures for analyzing both Stage II and Stage III soil and vacuum-cleaner collected house dust samples, and Stage III air samples u...
Yang, Lili; Liu, Guorui; Zheng, Minghui; Jin, Rong; Zhu, Qingqing; Zhao, Yuyang; Zhang, Xian; Xu, Yang
2017-02-15
Metallurgical plants are important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and polychlorinated naphthalenes (PCNs). It is significant to evaluate the air levels and human risks of PCDD/Fs, PCBs and PCNs in metallurgical plants considering their adverse effects on human health and thousands of metallurgical plants being in operation in China. The estimated inhalation intakes of PCDD/Fs, PCBs, and PCNs together in eight iron ore sintering plants, three secondary copper plants, four secondary aluminum plants, and one secondary lead plant were 4.9-213.4, 21.4-4026.4, 28.7-630, and 11.7fgTEQkg -1 day -1 , respectively, and the corresponding cancer risks were estimated to be 8.7×10 -7 to 3.8×10 -5 , 5.1×10 -6 to 1.1×10 -4 , 3.8×10 -6 to 7.1×10 -4 , and 2.1×10 -6 , respectively. The estimated cancer risk were higher than 100 per million people for three secondary aluminum and copper smelters among the sixteen metallurgical plants, indicating high cancer risks. Stack gas samples from metallurgical plants were also collected and analyzed for comparing their emission profiles with that of air samples. The comparison of PCDD/F, PCB and PCN profiles between air samples and stack gas samples by similarity calculation and principal component analysis suggested the influence of stack gas emissions from metallurgical plants on surrounding air. These results are helpful for understanding the exposure risk to PCDD/Fs, PCBs and PCNs in numerous metallurgical plants being operation in China. Copyright © 2016 Elsevier B.V. All rights reserved.
Hammond, Duane; Garcia, Alberto; Feng, H Amy
2011-07-01
A utility-scale wind turbine blade manufacturing plant requested assistance from the National Institute for Occupational Safety and Health (NIOSH) in controlling worker exposures to styrene at a plant that produced 37 and 42 m long fiber-reinforced wind turbine blades. The plant requested NIOSH assistance because previous air sampling conducted by the company indicated concerns about peak styrene concentrations when workers entered the confined space inside of the wind turbine blade. NIOSH researchers conducted two site visits and collected personal breathing zone and area air samples while workers performed the wind turbine blade manufacturing tasks of vacuum-assisted resin transfer molding (VARTM), gelcoating, glue wiping, and installing the safety platform. All samples were collected during the course of normal employee work activities and analyzed for styrene using NIOSH Method 1501. All sampling was task based since full-shift sampling from a prior Occupational Safety and Health Administration (OSHA) compliance inspection did not show any exposures to styrene above the OSHA permissible exposure limit. During the initial NIOSH site visit, 67 personal breathing zone and 18 area air samples were collected while workers performed tasks of VARTM, gelcoating, glue wipe, and installation of a safety platform. After the initial site visit, the company made changes to the glue wipe task that eliminated the need for workers to enter the confined space inside of the wind turbine blade. During the follow-up site visit, 12 personal breathing zone and 8 area air samples were collected from workers performing the modified glue wipe task. During the initial site visit, the geometric means of the personal breathing zone styrene air samples were 1.8 p.p.m. (n = 21) for workers performing the VARTM task, 68 p.p.m. (n = 5) for workers installing a safety platform, and 340 p.p.m. (n = 14) for workers performing the glue wipe task, where n is the number of workers sampled for a given mean result. Gelcoating workers included job categories of millers, gelcoat machine operators, and gelcoaters. Geometric mean personal breathing zone styrene air samples were 150 p.p.m. (n = 6) for millers, 87 p.p.m. (n = 2) for the gelcoat machine operators, and 66 p.p.m. (n = 19) for gelcoaters. The geometric mean of the personal breathing zone styrene air samples from the glue wipe task measured during the follow-up site visit was 31 p.p.m. (n = 12). The closed molding VARTM process was very effective at controlling worker exposures to styrene. Personal breathing zone styrene air samples were reduced by an order of magnitude after changes were made to the glue wipe task. The company used chemical substitution to eliminate styrene exposure during the installation of the safety platform. Recommendations were provided to reduce styrene concentrations during gelcoating.
Retrieved Products from Simulated Hyperspectral Observations of a Hurricane
NASA Technical Reports Server (NTRS)
Susskind, Joel; Kouvaris, Louis C.; Iredell, Lena; Blaisdell, John; Pagano, Thomas; Mathews, William
2015-01-01
This research uses GCM derived products, with 1 km spatial resolution and sampled every 10 minutes, over a moving area following the track of a simulated severe Atlantic storm. Model products were aggregated over sounder footprints corresponding to 13 km in LEO, 2 km in LEO, and 5 km in GEO sampled every 72 minutes. We simulated radiances for instruments with AIRS-like spectral coverage, spectral resolution, and channel noise, using these aggregated products as the truth, and analyzed them using a slightly modified version of the operational AIRS Version-6 retrieval algorithm. Accuracy of retrievals obtained using simulated AIRS radiances with a 13 km footprint was similar to that obtained using real AIRS data. Spatial coverage and accuracy of retrievals are shown for all three sounding scenarios. The research demonstrates the potential significance of flying Advanced AIRS-like instruments on future LEO and GEO missions.
Health hazard evaluation report HETA 90-048-2253, Haute Nails, Norman, Oklahoma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Almaguer, D.; Blade, L.M.
In response to a request from the owner/operator of the Haute Nails Salon, Norman, Oklahoma, an evaluation was undertaken of possible chemical exposures from the use of nail sculpturing products. Haute Nails was an artificial nail sculpturing and tanning salon employing two full time nail sculpturers and four part time receptionists. The company was located on the first floor of a two story brick building. Long term general area air sampling was conducted for volatile organic chemicals, formaldehyde, and methacrylates; personal breathing zone air sampling was conducted for methacrylates. Ethyl-methacrylate concentrations in long term samples ranged from 10.3 to 14.1more » mg/cu m. Breathing zone concentrations of ethyl-methacrylate were 128 mg/cu m for a 7 minute sample and 78.9 mg/cu m for a 14 minute sample during nail sculpturing. Carbon-dioxide measurements exceeded the recommended level of 1000 parts per million. The authors conclude that there were no overexposures to ethyl-methylacrylate during the evaluation. The heating and air conditioning system did not provide for the mechanical exchange of outside air and no exhaust fans were located in the area served by the system. The authors recommend that an outside air supply duct be added to the present system.« less
Weathered Oil and Tar Sampling Data for BP Spill/Deepwater Horizon
The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following the explosion and sinking of the Deepwater Horizon oil rig, a sea-floor oil gusher flowed for 87 days, until it was capped on 15 July 2010.In response to the BP oil spill, EPA sampled air, water, sediment, and waste generated by the cleanup operations.
Water Sampling Data for BP Spill/Deepwater Horizon
The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following the explosion and sinking of the Deepwater Horizon oil rig, a sea-floor oil gusher flowed for 87 days, until it was capped on 15 July 2010.In response to the BP oil spill, EPA sampled air, water, sediment, and waste generated by the cleanup operations.
Waste Sampling Data for BP Spill/Deepwater Horizon
The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following the explosion and sinking of the Deepwater Horizon oil rig, a sea-floor oil gusher flowed for 87 days, until it was capped on 15 July 2010.In response to the BP oil spill, EPA sampled air, water, sediment, and waste generated by the cleanup operations.
Surface Water Sampling Data for BP Spill/Deepwater Horizon
The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following the explosion and sinking of the Deepwater Horizon oil rig, a sea-floor oil gusher flowed for 87 days, until it was capped on 15 July 2010.In response to the BP oil spill, EPA sampled air, water, sediment, and waste generated by the cleanup operations.
Sediment Sampling Data for BP Spill/Deepwater Horizon
The Deepwater Horizon oil spill (also referred to as the BP oil spill) began on 20 April 2010 in the Gulf of Mexico on the BP-operated Macondo Prospect. Following the explosion and sinking of the Deepwater Horizon oil rig, a sea-floor oil gusher flowed for 87 days, until it was capped on 15 July 2010.In response to the BP oil spill, EPA sampled air, water, sediment, and waste generated by the cleanup operations.
30 CFR 70.207 - Bimonthly sampling; mechanized mining units.
Code of Federal Regulations, 2011 CFR
2011-07-01
... air will be used to determine the average concentration for that mechanized mining unit. (e) Unless... sampling device as follows: (1) Conventional section using cutting machine. On the cutting machine operator or on the cutting machine within 36 inches inby the normal working position; (2) Conventional section...
Korves, T M; Piceno, Y M; Tom, L M; Desantis, T Z; Jones, B W; Andersen, G L; Hwang, G M
2013-02-01
Air travel can rapidly transport infectious diseases globally. To facilitate the design of biosensors for infectious organisms in commercial aircraft, we characterized bacterial diversity in aircraft air. Samples from 61 aircraft high-efficiency particulate air (HEPA) filters were analyzed with a custom microarray of 16S rRNA gene sequences (PhyloChip), representing bacterial lineages. A total of 606 subfamilies from 41 phyla were detected. The most abundant bacterial subfamilies included bacteria associated with humans, especially skin, gastrointestinal and respiratory tracts, and with water and soil habitats. Operational taxonomic units that contain important human pathogens as well as their close, more benign relatives were detected. When compared to 43 samples of urban outdoor air, aircraft samples differed in composition, with higher relative abundance of Firmicutes and Gammaproteobacteria lineages in aircraft samples, and higher relative abundance of Actinobacteria and Betaproteobacteria lineages in outdoor air samples. In addition, aircraft and outdoor air samples differed in the incidence of taxa containing human pathogens. Overall, these results demonstrate that HEPA filter samples can be used to deeply characterize bacterial diversity in aircraft air and suggest that the presence of close relatives of certain pathogens must be taken into account in probe design for aircraft biosensors. A biosensor that could be deployed in commercial aircraft would be required to function at an extremely low false alarm rate, making an understanding of microbial background important. This study reveals a diverse bacterial background present on aircraft, including bacteria closely related to pathogens of public health concern. Furthermore, this aircraft background is different from outdoor air, suggesting different probes may be needed to detect airborne contaminants to achieve minimal false alarm rates. This study also indicates that aircraft HEPA filters could be used with other molecular techniques to further characterize background bacteria and in investigations in the wake of a disease outbreak. © 2012 John Wiley & Sons A/S.
Airborne Multidrug-Resistant Bacteria Isolated from a Concentrated Swine Feeding Operation
Chapin, Amy; Rule, Ana; Gibson, Kristen; Buckley, Timothy; Schwab, Kellogg
2005-01-01
The use of nontherapeutic levels of antibiotics in swine production can select for antibiotic resistance in commensal and pathogenic bacteria in swine. As a result, retail pork products, as well as surface and groundwaters contaminated with swine waste, have been shown to be sources of human exposure to antibiotic-resistant bacteria. However, it is unclear whether the air within swine operations also serves as a source of exposure to antibiotic-resistant bacterial pathogens. To investigate this issue, we sampled the air within a concentrated swine feeding operation with an all-glass impinger. Samples were analyzed using a method for the isolation of Enterococcus. A total of 137 presumptive Enterococcus isolates were identified to species level using standard biochemical tests and analyzed for resistance to erythromycin, clindamycin, virginiamycin, tetracycline, and vancomycin using the agar dilution method. Thirty-four percent of the isolates were confirmed as Enterococcus, 32% were identified as coagulase-negative staphylococci, and 33% were identified as viridans group streptococci. Regardless of bacterial species, 98% of the isolates expressed high-level resistance to at least two antibiotics commonly used in swine production. None of the isolates were resistant to vancomycin, an antibiotic that has never been approved for use in livestock in the United States. In conclusion, high-level multidrug-resistant Enterococcus, coagulase-negative staphylococci, and viridans group streptococci were detected in the air of a concentrated swine feeding operation. These findings suggest that the inhalation of air from these facilities may serve as an exposure pathway for the transfer of multidrug-resistant bacterial pathogens from swine to humans. PMID:15687049
Atmospheric Carbon Dioxide Record from In Situ Measurements at Baring Head (1970 - 1993)
Manning, M. R. [National Institute of Water and Atmospheric Research, Ltd., Lower Hutt, New Zealand; Gomez, A. J. [National Institute of Water and Atmospheric Research, Ltd., Lower Hutt, New Zealand; Pohl, K. P. [National Institute of Water and Atmospheric Research, Ltd. Lower Hutt, New Zealand
1994-01-01
Determinations of atmospheric CO2 mixing ratios are made using a Siemens Ultramat-3 nondispersive infrared (NDIR) gas analyzer. The NDIR CO2 analyzer is connected via a gas manifold consisting of stainless steel tubing and computer-controlled solenoid switches to 12 gas cylinders and 2 sample air lines. The NDIR analyzer compares ambient air CO2 mixing ratios relative to known CO2 mixing ratios in tanks of compressed reference gases. The analyzer operates in a differential mode, with a "zero" reference gas of CO2 mixing ratio 20 to 30 parts per million (ppm) below ambient air CO2 levels flowing continuously through one cell of the analyzer at ~10 mL/min. When atmospheric CO2 is measured, a diaphragm pump pulls air through a sampling line at ~5 L/min. A small fraction of this (180 mL/min) is dried cryogenically to a temperature of approximately ¬70° Celsius and passed through the sample cell of the CO2 analyzer. Both the "zero" and sample gas are exhausted into the observatory building.
Air quality during demolition and recovery activities in post-Katrina New Orleans.
Ravikrishna, Raghunathan; Lee, Han-Woong; Mbuligwe, Stephen; Valsaraj, K T; Pardue, John H
2010-07-01
Air samples were collected during demolition and cleanup operations in the Lakeview district of New Orleans, Louisiana, USA, in late 2005 during the period immediately after Hurricane Katrina. Three different high-volume air samples were collected around waste collection areas that were created to temporarily hold the debris from the cleanup of residential properties in the area. Particulate concentrations were elevated and included crystalline fibers associated with asbestos. Metal concentrations on particulate matter resembled those measured in sediments deposited by floodwaters with the exception of Ba, which was elevated at all three locations. The highest organic contaminant concentration measured on particulates was the pesticide Ziram (Zinc, bis[diethylcarbamodithioato-S,S']-, [T-4]-) at 2,200 microg/g of particulate matter during sampling period 2. Ziram is used in latex paint, adhesives, caulking, and wallboard as a preservative. Fungal isolates developed from particulate air samples included species associated with disease including Aspergillus and Penicillium species. These data represent the most comprehensive assessment of demolition activities during the period immediately after Hurricane Katrina. Copyright (c) 2010 SETAC.
Evaluation of portable air samplers for monitoring airborne culturable bacteria
NASA Technical Reports Server (NTRS)
Mehta, S. K.; Bell-Robinson, D. M.; Groves, T. O.; Stetzenbach, L. D.; Pierson, D. L.
2000-01-01
Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.
The report gives results of a project, in support of the intergrated Air Canver Project (IACP) to provide data on the specific effects of appliance type and operating variales on woodstove emissions. Samples of particulate material and volatile organic compounds (VOCs) were colle...
White, D.H.; Hardy, J.W.
1994-01-01
Our objective was to determine the levels of selected airborne contaminants in ambient air at the Mississippi Sandhill Crane National Wildlife Refuge, Mississippi, that might be affecting the health of endangered cranes living there. Two high-volume air samplers were operated at separate locations on the Refuge during May?September 1991. The sampling media were micro-quartz filters in combination with polyurethane foam plugs. Composite bimonthly samples from each station were analyzed for polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs), coplanar polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs). Overall, residue concentrations were low. The toxic PCDD isomer 2,3,7,8-tetra-CDD was not detected, nor was penta-CDD. There was no difference (P>0.05) in residue concentrations between stations or over time and meteorological parameters were not correlated with residue concentrations. Because contaminant levels and patterns may differ seasonally, we recommend that air samples collected during winter months also be analyzed for these same chemical groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perry, R.B.; Fiarman, S.; Jung, E.A.
1990-10-01
This paper is the final report on DOE-OSS Task ANLE88002 Fast Air Chamber Calorimetry.'' The task objective was to design, construct, and test an isothermal air chamber calorimeter for plutonium assay of bulk samples that would meet the following requirements for sample power measurement: average sample measurement time less than 20 minutes. Measurement of samples with power output up to 10 W. Precision of better than 1% RSD for sample power greater than 1 W. Precision better than 0.010 watt SD, for sample power less than 1 W. This report gives a description of the calorimeter hardware and software andmore » discusses the test results. The instrument operating procedure, included as an appendix, gives examples of typical input/output and explains the menu driven software. Sample measurement time of less than 20 minutes was attained by pre-equilibration of the samples in low cost precision preheaters and by prediction of equilibrium measurements. Tests at the TA55 Plutonium Facility at Los Alamos National Laboratory, on typical samples, indicates that the instrument meets all the measurement requirements.« less
Wise, Marcus B.; Thompson, Cyril V.
1998-01-01
An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds.
Determination and comparison of microbial loads in atmospheres of two hospitals in Izmir, Turkey.
Aydin Çakir, Nergüze; Uçar, Füsun Bahriye; Haliki Uztan, Alev; Corbaci, Cengiz; Akpinar, Onur
2013-01-01
Nosocomial infections, also known as hospital-acquired infections, has become one of the most important health problems in health care units worldwide. The presented study aims to determine the average amount of microorganism loads and to show that the atmospheres of the two hospitals can be a potential source regarding nosocomial infections. The effect of surface and floor disinfection processes in the two hospitals and the antibiotic susceptibility of the bacterial isolates were also evaluated. Microorganisms were isolated from air samples collected from different areas (patient wards, corridors, operating theatres and postoperative units) of the two hospitals in Izmir. Sampling was conducted between December 2006 - March 2007. During the 3-month sampling period, the average number of live microorganisms in the air samples collected from second-class environments in the hospital 1 and the hospital 2 was found to be 224.44 and 536.66 cfu/m(3) , respectively. The average number of microorganisms in hospital 2 collected before the disinfection process was higher than those after the disinfection process. However, because of the closure of the air-conditioning system and the hepa filters after the disinfection process, this was reversed in hospital 1. In total, 54 and 42 isolates were obtained from hospital 1 and hospital 2, respectively. 49 isolates from hospital 1 and 35 isolates from hospital 2 were identified as Staphylacoccus sp. The remaining isolates were identified as Aerococcus sp. and Enterococcus sp. Pseudomonas sp. was not determined in the air samples of the two hospitals. It was detected that the microbial loads in the atmospheres of the two hospitals studied varied greatly depending on the number of people in the environment. As the results indicate, the total number of microorganisms in the atmospheres of operating theatres in both hospitals does not pose a threat according to the Air Microbe Index.
US Fish and Wildlife Service biomonitoring operations manual, Appendices A--K
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gianotto, D.F.; Rope, R.C.; Mondecar, M.
1993-04-01
Volume 2 contains Appendices and Summary Sheets for the following areas: A-Legislative Background and Key to Relevant Legislation, B- Biomonitoring Operations Workbook, C-Air Monitoring, D-Introduction to the Flora and Fauna for Biomonitoring, E-Decontamination Guidance Reference Field Methods, F-Documentation Guidance, Sample Handling, and Quality Assurance/Quality Control Standard Operating Procedures, G-Field Instrument Measurements Reference Field Methods, H-Ground Water Sampling Reference Field Methods, I-Sediment Sampling Reference Field Methods, J-Soil Sampling Reference Field Methods, K-Surface Water Reference Field Methods. Appendix B explains how to set up strategy to enter information on the ``disk workbook``. Appendix B is enhanced by DE97006389, an on-line workbook formore » users to be able to make revisions to their own biomonitoring data.« less
Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1991
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-04-01
This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1991. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grote, R.A.
1991-05-01
The report is a recommended operating procedure (ROP), prepared for use in research activities conducted by EPA's Air and Energy Engineering Research Laboratory (AEERL). The method described is applicable to the stack sampling of flue gas from a rotary kiln and to associated equipment of AEERL's Combustion Research Branch. It has been the standard method of sampling kiln flue gas due to the transient nature of the puff development and its capability to sample the maximum volume over the shortest time period. ROPs describe non-routine or experimental research operations where some judgment in application may be warranted. ROPs may notmore » be applicable to activities conducted by other research groups, and should not be used in place of standard operating procedures. Use of ROPs must be accompanied by an understanding of the purpose and scope. Questions should be directed to the author.« less
Kuehl, Richard; Banderet, Florian; Egli, Adrian; Keller, Peter M; Frei, Reno; Döbele, Thomas; Eckstein, Friedrich; Widmer, Andreas F
2018-05-28
OBJECTIVEWorldwide, Mycobacterium chimaera infections have been linked to contaminated aerosols from heater-cooler units (HCUs) during open-heart surgery. These infections have mainly been associated with the 3T HCU (LivaNova, formerly Sorin). The reasons for this and the risk of transmission from other HCUs have not been systematically assessed.DESIGNProspective observational study.SETTINGUniversity Hospital Basel, Switzerland.METHODSContinuous microbiological surveillance of 3 types of HCUs in use (3T from LivaNova/Sorin and HCU30 and HCU40 from Maquet) was initiated in June 2014, coupled with an epidemiologic workup. Monthly water and air samples were taken. Construction design was analyzed, and exhausted airflow was measured.RESULTS Mycobacterium chimaera grew in 8 of 12 water samples (66%) and 22 of 24 air samples (91%) of initial 3T HCUs in use, and in 2 of 83 water samples (2%) and 0 of 41 (0%) air samples of new replacement 3T HCUs. Moreover, 7 of 12 water samples (58%) and 0 of 4 (0%) air samples from the HCU30 were positive, and 0 of 64 (0%) water samples and 0 of 50 (0%) air samples from the HCU40 were positive. We identified 4 relevant differences in HCU design compared to the 3T: air flow direction, location of cooling ventilators, continuous cooling of the water tank at 4°C, and an electronic alarm in the HCU40 reminding the user of the next disinfection cycle.CONCLUSIONSAll infected patients were associated with a 3T HCU. The individual HCU design may explain the different risk of disseminating M. chimaera into the air of the operating room. These observations can help the construction of improved devices to ensure patient safety during cardiac surgery.Infect Control Hosp Epidemiol 2018;1-7.
Rosenquist, Hanne; Sommer, Helle M; Nielsen, Niels L; Christensen, Bjarke B
2006-04-25
To evaluate the effect of specific slaughter operations on the contamination of broiler carcasses with naturally occurring thermotolerant Campylobacter, experiments were carried out in two Danish commercial slaughter plants (Plant I and Plant II). Six broiler flocks determined Campylobacter positive prior to slaughter were investigated at four sampling locations within each slaughter plant. Quantification of thermotolerant Campylobacter in 30 neck skin samples per flock per sampling location showed that the evisceration operation in Plant I led to a significant increase in the Campylobacter concentration of 0.5 log(10) cfu/g in average, whereas no significant changes were observed during this operation in Plant II. Air chilling (Plant I) and water chilling (Plant II), both including a carcass wash prior to the chilling operation, caused similar, but significant reductions of 0.83 and 0.97 log(10) cfu/g, respectively. In packed frozen chickens (Plant II) an additional reduction of 1.38 log(10) cfu/g in average was obtained due to the freezing operation. In packed chilled chickens (Plant I), however, the number of thermotolerant Campylobacter per gram remained at the same level as after air chilling. Enumeration of thermotolerant Campylobacter in 30 intestinal samples per flock showed that in two of the six flocks examined the within flock colonization was very low (<3% and 27% positive samples). The remaining four flocks were colonized at percentages of 100 (three flocks) and 97 (one flock) and had intestinal mean counts ranging from 6.65 to 8.20 log(10) cfu/g. A correlation between Campylobacter concentrations in intestinal content and on chicken carcasses after the defeathering operation was documented. This finding indicates that a reduction in the Campylobacter concentration on chicken carcasses may also be obtained by interventions aimed at reducing the concentration of Campylobacter in the intestines of the living birds.
Microtrap assembly for greenhouse gas and air pollution monitoring
Mitra, Somenath; Saridara, Chutarat
2015-08-25
A microtrap assembly includes a carbon nanotube sorbent. The microtrap assembly may be employed as a preconcentrator operable to deliver a sample to an analytical device to measure the concentrations of greenhouse gases. A system includes a microtrap having a carbon nanotube sorbent for measuring the concentrations of greenhouse gases in a sample.
The U.S. EPA has established a National Dioxin Air Monitoring Network (NDAMN) to determine the temporal and geographical variability of atmospheric CDDs, CDFs and coplanar PCBs at rural and nonimpacted locations throughout the United States. Currently operating at 32 sampling st...
2016-05-24
common feature of the depressive and anxiety disorders: a test of the revised integrative hierarchical model in a national sample. J Abnorm Psychol...proliferation of this unique form of warfare, concerns have been raised regarding the psychological impact such operations have on RPA operators directly...and clinical interviews utilizing the Clinician Administered Psychological Survey to determine the nature of the respondents’ stressful military
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-04-01
This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1992. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiationmore » levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. Small amounts of Co-60 and Cs-134 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public.« less
The effect of an ion generator on indoor air quality in a residential room.
Waring, M S; Siegel, J A
2011-08-01
Ion generators charge particles with a corona prior to their removal on collector plates or indoor surfaces and also emit ozone, which can react with terpenes to yield secondary organic aerosol, carbonyls, carboxylic acids, and free radicals. This study characterized the indoor air quality implications of operating an ion generator in a 27 m(3) residential room, with four different test room configurations. Two room configurations had carpet overlaying the original flooring of stained/sealed concrete, and for one configuration with and without carpet, a plug-in air freshener was used as a terpene source. Measurements included airborne sampling of particulate matter (0.015-20 μm), terpenes and C(1) -C(4) and C(6) -C(10) aldehydes, ozone concentrations, and air exchange rates. When the heating, ventilating, and air-conditioning system was not operating (room air exchange rate = ∼0.5/h), the use of the ion generator in the presence of the air freshener led to a net increase in ultrafine particles (<0.1 μm). Also, increased concentrations of ozone were observed regardless of air freshener presence, as well as increases in formaldehyde and nonanal, albeit within measurement uncertainty in some cases. Thus, it may be prudent to limit ion generator use indoors until evidence of safety can be ascertained. Portable ion generators are intended to clean the air of particles, but they may emit ozone as a byproduct of their operation, which has the potential to degrade indoor air quality. This study showed that under certain conditions in a residential room, the use of a portable ion generator can increase concentrations of ozone and, to a lesser degree, potentially aldehydes. Also, if operated in the presence of a plug-in air freshener that emits terpenes, its use can increase concentrations of secondary organic aerosol in the ultrafine size range. © 2010 John Wiley & Sons A/S.
Air Sample Conditioner Helps the Waste Treatment Plant Meet Emissions Standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glissmeyer, John A.; Flaherty, Julia E.; Pekour, Mikhail S.
2014-12-02
The air in three of the Hanford Site Waste Treatment and Immobilization Plant (WTP) melter off-gas discharge stacks will be hot and humid after passing through the train of emission abatement equipment. The off-gas temperature and humidity levels will be incompatible with the airborne emissions monitoring equipment required for this type of stack. To facilitate sampling from these facilities, an air sample conditioner system will be installed to introduce cool, dry air into the sample stream to reduce the temperature and dew point. This will avoid thermal damage to the instrumentation and problematic condensation. The complete sample transport system mustmore » also deliver at least 50% of the particles in the sample airstream to the sample collection and on-line analysis equipment. The primary components of the sample conditioning system were tested in a laboratory setting. The sample conditioner itself is based on a commercially-available porous tube filter design. It consists of a porous sintered metal tube inside a coaxial metal jacket. The hot gas sample stream passes axially through the porous tube, and the dry, cool air is injected into the jacket and through the porous wall of the inner tube, creating an effective sample diluter. The dilution and sample air mix along the entire length of the porous tube, thereby simultaneously reducing the dew point and temperature of the mixed sample stream. Furthermore, because the dilution air enters through the porous tube wall, the sample stream does not come in contact with the porous wall and particle deposition is reduced in this part of the sampling system. Tests were performed with an environmental chamber to supply air with the temperature and humidity needed to simulate the off-gas conditions. Air from the chamber was passed through the conditioning system to test its ability to reduce the temperature and dew point of the sample stream. To measure particle deposition, oil droplets in the range of 9 to 11 micrometer aerodynamic diameter were injected into the environmental chamber and drawn through the conditioning system, which included a filter to capture droplets that passed through the conditioner. The droplets were tagged with a fluorescent dye which allowed quantification of droplet deposition on each component of the system. The tests demonstrated the required reductions in temperature and moisture, with no condensation forming when heat tracing was added on the upstream end of the sample conditioner. Additionally, tests indicated that the system, operating at several flow rates and in both vertical and horizontal orientations, delivers nearly all of the sampled particles for analysis. Typical aerosol penetration values were between 98 and 99%. PNNL, Bechtel National Inc., and the instrument vendor are working to implement the sample conditioner into the air monitoring systems used for the melter off-gas exhaust streams. Similar technology may be useful for processes in other facilities with air exhaust streams with elevated temperature and/or humidity.« less
Journal Article: the National Dioxin Air Monitoring Network ...
The U.S. EPA has established a National Dioxin Air Monitoring Network (NDAMN) to determine the temporal and geographical variability of atmospheric CDDs, CDFs and coplanar PCBs at rural and nonimpacted locations throughout the United States. Currently operating at 32 sampling stations, NDAMN has three primary purposes: (1) to determine the atmospheric levels and occurrences of dioxin-like compounds in rural and agricultural areas where livestock, poultry and animal feed crops are grown; (2) to provide measurements of atmospheric levels of dioxin-like compounds in different geographic regions of the U.S.; and (3) to provide information regarding the long-range transport of dioxin-like compounds in air over the U.S. Designed in 1997, NDAMN has been implemented in phases, with the first phase consisting of 9 monitoring stations. Previously EPA has reported on the preliminary results of monitoring at 9 rural locations from June1998 through June 19991. The one-year measurement at the 9 stations indicated an annual mean TEQDF–WHO98 air concentration of 12 fg m-3. Since this reporting, NDAMN has been extended to include additional stations. The following is intended to be an update to this national monitoring effort. We are reporting the air monitoring results of 22 NDAMN stations operational over 9 sampling moments from June 1998 to December 1999. Fifteen stations are in rural areas, and 6 are located in National Parks. One station is located in suburban Wa
Personal exposure to JP-8 jet fuel vapors and exhaust at air force bases.
Pleil, J D; Smith, L B; Zelnick, S D
2000-03-01
JP-8 jet fuel (similar to commercial/international jet A-1 fuel) is the standard military fuel for all types of vehicles, including the U.S. Air Force aircraft inventory. As such, JP-8 presents the most common chemical exposure in the Air Force, particularly for flight and ground crew personnel during preflight operations and for maintenance personnel performing routine tasks. Personal exposure at an Air Force base occurs through occupational exposure for personnel involved with fuel and aircraft handling and/or through incidental exposure, primarily through inhalation of ambient fuel vapors. Because JP-8 is less volatile than its predecessor fuel (JP-4), contact with liquid fuel on skin and clothing may result in prolonged exposure. The slowly evaporating JP-8 fuel tends to linger on exposed personnel during their interaction with their previously unexposed colleagues. To begin to assess the relative exposures, we made ambient air measurements and used recently developed methods for collecting exhaled breath in special containers. We then analyzed for certain volatile marker compounds for JP-8, as well as for some aromatic hydrocarbons (especially benzene) that are related to long-term health risks. Ambient samples were collected by using compact, battery-operated, personal whole-air samplers that have recently been developed as commercial products; breath samples were collected using our single-breath canister method that uses 1-L canisters fitted with valves and small disposable breathing tubes. We collected breath samples from various groups of Air Force personnel and found a demonstrable JP-8 exposure for all subjects, ranging from slight elevations as compared to a control cohort to > 100 [mutilpe] the control values. This work suggests that further studies should be performed on specific issues to obtain pertinent exposure data. The data can be applied to assessments of health outcomes and to recommendations for changes in the use of personal protective equipment that optimize risk reduction without undue impact on a mission.
Micro Unmanned Surface Vehicle for Shallow Littoral Data Sampling
NASA Astrophysics Data System (ADS)
Murphy, R. R.; Wilde, G.
2016-02-01
This paper describes the creation of an autonomous air boat that can be carried by one person, called a micro unmanned surface vehicle (USV), for sensor sampling in shallow littoral areas such as inlets and creeks. A USV offers advantages over other types of unmanned marine vehicles. Unlike an autonomous underwater vehicle, the Challenge 1.0 air boat can operate in shallow water of less than 15 cm depth and maintain network connectivity for control and data sampling. A USV does not require a tether, like a remotely operated marine vehicle (ROV), which would limit the distance and mobility. However, a USV operating in shallow littoral areas poses several challenges. Navigation is a challenge since rivers and bays may have semi-submerged obstacles and there may be no depth maps; the approach taken in the Challenge 1.0 project is to let the operator specify a safe area of the water by visual inspection and then the USV autonomously creates a path to optimally sample the collision free area. Navigation is also a challenge because of platform dynamics-the USV we describe is a non-holonomic vehicle; this paper explores spiral paths rather than boustrophedon paths. Another challenge is the quality of sensing. Water-based sensing is noisy and thus a reading at a single point may not reflect the overall value. In practice, areas are sampled rather than a single point, but the noise in the point values within the sampled area produce a survey with widely varying numbers and are difficult for humans to interpret. This paper implements an inverse distance weighting interpolation algorithm to produce a visual "heatmap" that reliably portrays the smoothed data.
Kasina, Piotr; Tammelin, Ann; Blomfeldt, Anne-Marie; Ljungqvist, Bengt; Reinmüller, Berit; Ottosson, Carin
2016-01-01
Lowering air-borne bacteria counts in the operating room is essential in prevention of surgical site infections in orthopaedic joint replacement surgery. This is mainly achieved by decreasing bacteria counts through dilution, with appropriate ventilation and by limiting the bacteria carrying skin particles, predominantly shed by the personnel. The aim of this study was to investigate if a single use polypropylene clothing system or a reusable polyester clothing system could offer similar air quality in the operating room as a mobile laminar airflow device-assisted reusable cotton/polyester clothing system. Prospective observational study design, comparing the performance of three Clean Air Suits by measuring Colony Forming Units (CFU)/m(3) of air during elective hip and knee arthroplasties, performed at a large university-affiliated hospital. The amount of CFU/m(3) of air was measured during 37 operations of which 13 were performed with staff dressed in scrub suits made of a reusable mixed material (69 % cotton, 30 % polyester, 1 % carbon fibre) accompanied by two mobile laminar airflow units. During 24 procedures no mobile laminar airflow units were used, 13 with staff using a reusable olefin fabric clothing (woven polypropylene) and 11 with staff dressed in single-use suits (non-woven spunbonded polypropylene). Air from the operating field was sampled through a filter, by a Sartorius MD8, and bacterial colonies were counted after incubation. There were 6-8 measurements from each procedure, in total 244 measurements. Statistical analysis was performed by Mann-Whitney U-test. The single-use polypropylene suit reduced the amount of CFU/m(3) to a significantly lower level than both other clothing systems. Single-use polypropylene clothing systems can replace mobile laminar airflow unit-assisted reusable mixed material-clothing systems. Measurements in standardized laboratory settings can only serve as guidelines as environments in real operation settings present a much more difficult challenge.
Upper atmosphere pollution measurements (GASP)
NASA Technical Reports Server (NTRS)
Rudey, R. A.; Holdeman, J. D.
1975-01-01
The environmental effects are discussed of engine effluents of future large fleets of aircraft operating in the stratosphere. Topics discussed include: atmospheric properties, aircraft engine effluents, upper atmospheric measurements, global air sampling, and data reduction and analysis
SRS environmental air surveillance program 1954-2015: General trends
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abbott, K.; Jannik, T.
The radiological monitoring program at SRS was established under the DuPont Company in June 1951 and was used as a measurement of the effectiveness of plant controls and as an authoritative record of environmental conditions surrounding the plant. It also served as a method of demonstrating compliance with applicable federal regulations and guidance. This document serves as a general summary of changes made specifically to the environmental air monitoring program since its inception, and a discussion of the general trends seen in the air monitoring program at SRS from 1954 to 2015. Initially, the environmental air surveillance program focused notmore » only on releases from SRS but also on fallout from various weapons testing performed through the end of 1978. Flypaper was used to measure the amount of fallout in the atmosphere during this period, and was present at each of the 10 monitoring stations. By 1959, all site stacks were included in the air monitoring program to determine their contribution to the airborne radioactivity onsite, and the number of air surveillance samplers rose to 18. This trend of an increased number of sampling locations continued to a peak of 35 sampling locations before shifting to a downward trend in the mid-1990s. In 1962, 4 outer-range samplers were placed in Savannah and Macon, GA, and in Greenville and Columbia, SC. Until 1976, air samplers were simply placed around the perimeter of the various operation locations (after 1959, this included stacks to determine their contribution to the airborne radioactivity), with the intent of creating as representative a distribution as possible of the air surrounding operations.« less
Monitoring space shuttle air quality using the Jet Propulsion Laboratory electronic nose
NASA Technical Reports Server (NTRS)
Ryan, Margaret Amy; Zhou, Hanying; Buehler, Martin G.; Manatt, Kenneth S.; Mowrey, Victoria S.; Jackson, Shannon P.; Kisor, Adam K.; Shevade, Abhijit V.; Homer, Margie L.
2004-01-01
A miniature electronic nose (ENose) has been designed and built at the Jet Propulsion Laboratory (JPL), Pasadena, CA, and was designed to detect, identify, and quantify ten common contaminants and relative humidity changes. The sensing array includes 32 sensing films made from polymer carbon-black composites. Event identification and quantification were done using the Levenberg-Marquart nonlinear least squares method. After successful ground training, this ENose was used in a demonstration experiment aboard STS-95 (October-November, 1998), in which the ENose was operated continuously for six days and recorded the sensors' response to the air in the mid-deck. Air samples were collected daily and analyzed independently after the flight. Changes in shuttle-cabin humidity were detected and quantified by the JPL ENose; neither the ENose nor the air samples detected any of the contaminants on the target list. The device is microgravity insensitive.
Wise, M.B.; Thompson, C.V.
1998-07-14
An in-line gas monitor capable of accurate gas composition analysis in a continuous real time manner even under strong applied vacuum conditions operates by mixing an air sample with helium forming a sample gas in two complementary sample loops embedded in a manifold which includes two pairs of 3-way solenoid valves. The sample gas is then analyzed in an ion trap mass spectrometer on a continuous basis. Two valve drivers actuate the two pairs of 3-way valves in a reciprocating fashion, so that there is always flow through the in-line gas monitor via one or the other of the sample loops. The duty cycle for the two pairs of 3-way valves is varied by tuning the two valve drivers to a duty cycle typically between 0.2 to 0.7 seconds. 3 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harlos, D.P.; Edgerton, E.S.
1994-12-31
The US EPA has, under the auspices of the CASTNet program (Clean Air Status and Trends Network), initiated the CASTNet Air Toxics Monitoring Program (CATMP). Volatile Organic Compounds (VOC) and carbonyls and metals are sampled for 24-hour periods on a 12-day schedule using TO-14 samplers (SUMMA canisters) and dinitrophenylhydrazine-coated (dmph) sorbent cartridges and high volume particle samplers. Sampling was begun at most sites in July of 1993. The sites are operated by state and local air pollution control programs and all analysis is performed by Environmental Science and Engineering (ESE) in Gainesville, Florida. The network currently supports 15 VOC sites,more » of which 7 also sample carbonyls. Three sites sample metals only in Pinellas County, Florida. The limits of detection of 0.05 ppb for VOCs allow routine tracking of a wide range of pollutants including several greenhouse gases, transportation pollutants and photochemically-derived compounds. The sites range from major urban areas (Chicago, St. Louis) to a rural village (Waterbury, Vermont). Results of the first three quarters of VOC and carbonyl data collection are summarized in this presentation.« less
An automated system for global atmospheric sampling using B-747 airliners
NASA Technical Reports Server (NTRS)
Lew, K. Q.; Gustafsson, U. R. C.; Johnson, R. E.
1981-01-01
The global air sampling program utilizes commercial aircrafts in scheduled service to measure atmospheric constituents. A fully automated system designed for the 747 aircraft is described. Airline operational constraints and data and control subsystems are treated. The overall program management, system monitoring, and data retrieval from four aircraft in global service is described.
The purpose of this SOP is to describe the in-field use of the particulate sampling system (pumping, control unit, and size selective inlet impactors) for collecting samples of particulate matter from the air during a predetermined time period during the Arizona NHEXAS project an...
Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section.
Patts, Justin R; Barone, Teresa L
2017-05-01
Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over "off-the-shelf" sampling cassettes.
Comparison of coarse coal dust sampling techniques in a laboratory-simulated longwall section
Patts, Justin R.; Barone, Teresa L.
2017-01-01
Airborne coal dust generated during mining can deposit and accumulate on mine surfaces, presenting a dust explosion hazard. When assessing dust hazard mitigation strategies for airborne dust reduction, sampling is done in high-velocity ventilation air, which is used to purge the mining face and gallery tunnel. In this environment, the sampler inlet velocity should be matched to the air stream velocity (isokinetic sampling) to prevent oversampling of coarse dust at low sampler-to-air velocity ratios. Low velocity ratios are often encountered when using low flow rate, personal sampling pumps commonly used in underground mines. In this study, with a goal of employing mine-ready equipment, a personal sampler was adapted for area sampling of coarse coal dust in high-velocity ventilation air. This was done by adapting an isokinetic nozzle to the inlet of an Institute of Occupational Medicine (Edinburgh, Scotland) sampling cassette (IOM). Collected dust masses were compared for the modified IOM isokinetic sampler (IOM-MOD), the IOM without the isokinetic nozzle, and a conventional dust sampling cassette without the cyclone on the inlet. All samplers were operated at a flow rate typical of personal sampling pumps: 2 L/min. To ensure differences between collected masses that could be attributed to sampler design and were not influenced by artifacts from dust concentration gradients, relatively uniform and repeatable dust concentrations were demonstrated in the sampling zone of the National Institute for Occupational Safety and Health experimental mine gallery. Consistent with isokinetic theory, greater differences between isokinetic and non-isokinetic sampled masses were found for larger dust volume-size distributions and higher ventilation air velocities. Since isokinetic sampling is conventionally used to determine total dust concentration, and isokinetic sampling made a difference in collected masses, the results suggest when sampling for coarse coal dust the IOM-MOD may improve airborne coarse dust assessments over “off-the-shelf” sampling cassettes. PMID:27792474
Water vapor measurement system in global atmospheric sampling program, appendix
NASA Technical Reports Server (NTRS)
Englund, D. R.; Dudzinski, T. J.
1982-01-01
The water vapor measurement system used in the NASA Global Atmospheric Sampling Program (GASP) is described. The system used a modified version of a commercially available dew/frostpoint hygrometer with a thermoelectrically cooled mirror sensor. The modifications extended the range of the hygrometer to enable air sample measurements with frostpoint temperatures down to -80 C at altitudes of 6 to 13 km. Other modifications were made to permit automatic, unattended operation in an aircraft environment. This report described the hygrometer, its integration with the GASP system, its calibration, and operational aspects including measurement errors. The estimated uncertainty of the dew/frostpoint measurements was + or - 1.7 Celsius.
Predicting Air Quality at First Ingress into Vehicles Visiting the International Space Station.
Romoser, Amelia A; Scully, Robert R; Limero, Thomas F; De Vera, Vanessa; Cheng, Patti F; Hand, Jennifer J; James, John T; Ryder, Valerie E
2017-02-01
NASA regularly performs ground-based offgas tests (OGTs), which allow prediction of accumulated volatile pollutant concentrations at first entry on orbit, on whole modules and vehicles scheduled to connect to the International Space Station (ISS). These data guide crew safety operations and allow for estimation of ISS air revitalization systems impact from additional pollutant load. Since volatiles released from vehicle, module, and payload materials can affect crew health and performance, prediction of first ingress air quality is important. To assess whether toxicological risk is typically over or underpredicted, OGT and first ingress samples from 10 vehicles and modules were compared. Samples were analyzed by gas chromatography and gas chromatography-mass spectrometry. The rate of pollutant accumulation was extrapolated over time. Ratios of analytical values and Spacecraft Maximum Allowable Concentrations were used to predict total toxicity values (T-values) at first entry. Results were also compared by compound. Frequently overpredicted was 2-butanone (9/10), whereas propanal (6/10) and ethanol (8/10) were typically underpredicted, but T-values were not substantially affected. Ingress sample collection delay (estimated by octafluoropropane introduced from ISS atmosphere) and T-value prediction accuracy correlated well (R2 = 0.9008), highlighting the importance of immediate air sample collection and accounting for ISS air dilution. Importantly, T-value predictions were conservative 70% of the time. Results also suggest that T-values can be normalized to octafluoropropane levels to adjust for ISS air dilution at first ingress. Finally, OGT and ingress sampling has allowed small leaks in vehicle fluid systems to be recognized and addressed.Romoser AA, Scully RR, Limero TF, De Vera V, Cheng PF, Hand JJ, James JT, Ryder VE. Predicting air quality at first ingress into vehicles visiting the International Space Station. Aerosp Med Hum Perform. 2017; 88(2):104-113.
NASA Technical Reports Server (NTRS)
Wallace, William T.; Limero, Thomas F.; Gazda, Daniel B.; Macatangay, Ariel V.; Dwivedi, Prabha; Fernandez, Facundo M.
2014-01-01
In the history of manned spaceflight, environmental monitoring has relied heavily on archival sampling. For short missions, this type of sample collection was sufficient; returned samples provided a snapshot of the presence of chemical and biological contaminants in the spacecraft air and water. However, with the construction of the International Space Station (ISS) and the subsequent extension of mission durations, soon to be up to one year, the need for enhanced, real-time environmental monitoring became more pressing. The past several years have seen the implementation of several real-time monitors aboard the ISS, complemented with reduced archival sampling. The station air is currently monitored for volatile organic compounds (VOCs) using gas chromatography-differential mobility spectrometry (Air Quality Monitor [AQM]). The water on ISS is analyzed to measure total organic carbon and biocide concentrations using the Total Organic Carbon Analyzer (TOCA) and the Colorimetric Water Quality Monitoring Kit (CWQMK), respectively. The current air and water monitors provide important data, but the number and size of the different instruments makes them impractical for future exploration missions. It is apparent that there is still a need for improvements in environmental monitoring capabilities. One such improvement could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for target compounds present in air samples, and many of the compounds are also targets for water quality monitoring, this instrument provides a logical starting point to evaluate the feasibility of this approach. In this presentation, we will discuss our recent studies aimed at determining an appropriate method for introducing VOCs from water samples into the gas phase and our current work, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target analytes at the relevant concentrations at which they are routinely detected in archival water samples from the ISS.
Journal Article: EPA's National Dioxin Air Monitoring Network ...
The U.S. Environmental Protection Agency (U.S. EPA) established the National Dioxin Air Monitoring Network (NDAMN) in June of 1998, and operated it until November of 2004. The objective of NDAMN was to determine background air concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (dl-PCBs). NDAMN started with 10 sampling sites, adding more over time until the final count of 34 sites was reached by the beginning of 2003. Samples were taken quarterly, and the final sample count was 685. All samples were measured for 17 PCDD/PCDF congeners, 8 PCDD/PCDF homologue groups, and 7 dl-PCBs (note: 5 additional dl-PCBs were added for samples starting in the summer of 2002; 317 samples had measurements of 12 dl-PCBs). The overall average total toxic equivalent (TEQ) concentration in the United States was 11.2 fg TEQ m−3 with dl-PCBs contributing 0.8 fg TEQ m−3 (7%) to this total. The archetype dioxin and furan background air congener profile was seen in the survey averages and in most individual samples. This archetype profile is characterized by low and similar concentrations for tetra – through hexa PCDD/PCDF congeners, with elevations in four congeners – a hepta dioxin and furan congener, and both octa congeners. Sites were generally categorized as urban (4 sites), rural (23 sites), or remote (7 sites). The average TEQ concentrations over all sites and samples within these cat
Airborne contaminants during controlled residential fires.
Fent, Kenneth W; Evans, Douglas E; Babik, Kelsey; Striley, Cynthia; Bertke, Stephen; Kerber, Steve; Smith, Denise; Horn, Gavin P
2018-05-01
In this study, we characterize the area and personal air concentrations of combustion byproducts produced during controlled residential fires with furnishings common in 21 st century single family structures. Area air measurements were collected from the structure during active fire and overhaul (post suppression) and on the fireground where personnel were operating without any respiratory protection. Personal air measurements were collected from firefighters assigned to fire attack, victim search, overhaul, outside ventilation, and command/pump operator positions. Two different fire attack tactics were conducted for the fires (6 interior and 6 transitional) and exposures were compared between the tactics. For each of the 12 fires, firefighters were paired up to conduct each job assignment, except for overhaul that was conducted by 4 firefighters. Sampled compounds included polycyclic aromatic hydrocarbons (PAHs), volatile organic compounds (VOCs, e.g., benzene), hydrogen cyanide (HCN), and particulate (area air sampling only). Median personal air concentrations for the attack and search firefighters were generally well above applicable short-term occupational exposure limits, with the exception of HCN measured from search firefighters. Area air concentrations of all measured compounds decreased after suppression. Personal air concentrations of total PAHs and benzene measured from some overhaul firefighters exceeded exposure limits. Median personal air concentrations of HCN (16,300 ppb) exceeded the exposure limit for outside vent firefighters, with maximum levels (72,900 ppb) higher than the immediately dangerous to life and health (IDLH) level. Median air concentrations on the fireground (including particle count) were above background levels and highest when collected downwind of the structure and when ground-level smoke was the heaviest. No statistically significant differences in personal air concentrations were found between the 2 attack tactics. The results underscore the importance of wearing self-contained breathing apparatus when conducting overhaul or outside ventilation activities. Firefighters should also try to establish command upwind of the structure fire, and if this cannot be done, respiratory protection should be considered.
Atomic force microscopy imaging of macromolecular complexes.
Santos, Sergio; Billingsley, Daniel; Thomson, Neil
2013-01-01
This chapter reviews amplitude modulation (AM) AFM in air and its applications to high-resolution imaging and interpretation of macromolecular complexes. We discuss single DNA molecular imaging and DNA-protein interactions, such as those with topoisomerases and RNA polymerase. We show how relative humidity can have a major influence on resolution and contrast and how it can also affect conformational switching of supercoiled DNA. Four regimes of AFM tip-sample interaction in air are defined and described, and relate to water perturbation and/or intermittent mechanical contact of the tip with either the molecular sample or the surface. Precise control and understanding of the AFM operational parameters is shown to allow the user to switch between these different regimes: an interpretation of the origins of topographical contrast is given for each regime. Perpetual water contact is shown to lead to a high-resolution mode of operation, which we term SASS (small amplitude small set-point) imaging, and which maximizes resolution while greatly decreasing tip and sample wear and any noise due to perturbation of the surface water. Thus, this chapter provides sufficient information to reliably control the AFM in the AM AFM mode of operation in order to image both heterogeneous samples and single macromolecules including complexes, with high resolution and with reproducibility. A brief introduction to AFM, its versatility and applications to biology is also given while providing references to key work and general reviews in the field.
Efficiencies of Tritium (3H) bubbling systems.
Duda, Jean-Marie; Le Goff, Pierre; Leblois, Yoan; Ponsard, Samuel
2018-09-01
Bubbling systems are among the devices most used by nuclear operators to measure atmospheric tritium activity in their facilities or the neighbouring environment. However, information about trapping efficiency and bubbling system oxidation is not accessible and/or, at best, only minimally supported by demonstrations in actual operating conditions. In order to evaluate easily these parameters and thereby meet actual normative and regulatory requirements, a statistical study was carried out over 2000 monitoring records from the CEA Valduc site. From this data collection obtained over recent years of monitoring the CEA Valduc facilities and environment, a direct relation was highlighted between the 3H-samplers trapping efficiency of tritium as tritiated water and the sampling time and conditions of use: temperature and atmospheric moisture. It was thus demonstrated that this efficiency originated from two sources. The first one is intrinsic to the bubbling system operating parameters and the sampling time. That part applies equally to all four bubblers. The second part, however, is specific to the first bubbler. In essence, it depends on the sampling time and the sampled air characteristics. It was also highlighted that the water volume variation in the first bubbler, between the beginning and the end of the sampling process, is directly related to the average water concentration of the sampled air. In this way, it was possible to model the variations in trapping efficiency of the 3H-samplers relative to the sampling time and the water volume variation in the first bubbler. This model makes it possible to obtain the quantities required to comply with the current standards governing the monitoring of radionuclides in the environment and to associate an uncertainty concerning the measurements as well as the sampling parameters. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Limero, Thomas; Jones, Jared; Wallace, William; Mudgett, Paul
2015-01-01
The air quality monitor (AQM) began operations on the International Space Station (ISS) in March 2013 and was validated for operational use in January 2014. The AQM is a gas chromatograph-differential mobility spectrometer that currently monitors 22 target compounds in the ISS atmosphere. Data are collected twice per week, although data collection can be more frequent in contingency situations. In its second year, the AQM has provided data to decision-makers on several ISS contaminant related issues in both air and water. AQM has been used in strictly air incidents, such as a potential ammonia leak, and to investigate air contaminants affecting the water processing (excess ethanol). In the latter case data from water monitors and AQM were compared to understand the issue with the water processor. Additionally, the AQM has been moved to different ISS modules to determine whether air is sufficiently mixed between modules so that a central LAB module location is representative of the entire ISS atmosphere. Historic data on the ISS atmosphere in different modules from archival samples (ground lab analysis) suggest that the atmosphere is usually homogenous. This presentation will briefly describe the technical aspects of the AQM operations and summarize the validation results. The main focus of the presentation will be to discuss the results from the AQM survey of the ISS modules and to show how the AQM data has contributed to an understanding of environmental issues that have arisen on ISS. Presentation of a potential ammonia leak (indicated by an alarm) in 2015 will illustrate the use and value of the AQM in such situations.
Bender, David A.; Rowe, Barbara L.
2015-01-01
Ellsworth Air Force Base is an Air Combat Command located approximately 10 miles northeast of Rapid City, South Dakota. Ellsworth Air Force Base occupies about 6,000 acres within Meade and Pennington Counties, and includes runways, airfield operations, industrial areas, housing, and recreational facilities. Fuels Area C within Ellsworth Air Force Base is a fuels storage area that is used to support the mission of the base. In fall of 2013, the U.S. Geological Survey began a study in cooperation with the U.S. Air Force, Ellsworth Air Force Base, to estimate groundwater-flow direction, select locations for permanent monitoring wells, and install and sample monitoring wells for petroleum hydrocarbon compounds within Fuels Area C. Nine monitoring wells were installed for the study within Fuels Area C during November 4–7, 2014. Soil core samples were collected during installation of eight of the monitoring wells and analyzed for benzene, toluene, ethylbenzene, total xylenes, naphthalene,m- and p-xylene, o-xylene, and gasoline- and diesel-range organic compounds. Groundwater samples were collected from seven of the nine wells (two of the monitoring wells did not contain enough water to sample or were dry) during November 19–21, 2014, and analyzed for select physical properties, benzene, toluene, ethylbenzene, total xylenes, naphthalene, m- and p-xylene, o-xylene, and gasoline- and diesel-range organic compounds. This report describes the nine monitoring well locations and presents the soil- and groundwater-quality data collected in 2014 for this study.
Prolonged Outbreak of Mycobacterium chimaera Infection After Open-Chest Heart Surgery.
Sax, Hugo; Bloemberg, Guido; Hasse, Barbara; Sommerstein, Rami; Kohler, Philipp; Achermann, Yvonne; Rössle, Matthias; Falk, Volkmar; Kuster, Stefan P; Böttger, Erik C; Weber, Rainer
2015-07-01
Invasive Mycobacterium chimaera infections were diagnosed in 2012 in 2 heart surgery patients on extracorporeal circulation. We launched an outbreak investigation to identify the source and extent of the potential outbreak and to implement preventive measures. We collected water samples from operating theaters, intensive care units, and wards, including air samples from operating theaters. Mycobacterium chimaera strains were characterized by randomly amplified polymorphic DNA polymerase chain reaction (RAPD-PCR). Case detection was performed based on archived histopathology samples and M. chimaera isolates since 2006, and the patient population at risk was prospectively surveyed. We identified 6 male patients aged between 49 and 64 years with prosthetic valve endocarditis or vascular graft infection due to M. chimaera, which became clinically manifest with a latency of between 1.5 and 3.6 years after surgery. Mycobacterium chimaera was isolated from cardiac tissue specimens, blood cultures, or other biopsy specimens. We were able also to culture M. chimaera from water circuits of heater-cooler units connected to the cardiopulmonary bypass, and air samples collected when the units were in use. RAPD-PCR demonstrated identical patterns among M. chimaera strains from heater-cooler unit water circuits and air samples, and strains in 2 patient clusters. The epidemiological and microbiological features of this prolonged outbreak provided evidence for the airborne transmission of M. chimaera from contaminated heater-cooler unit water tanks to patients during open-heart surgery. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
1984-10-01
are shared with the production facility. I Capital Costs: $260,000 (1976) plus $45,000 for the building. Operating and Maintenance Costs: O&M costs are...agricultural product processing plant. Operation: Three shifts, 5.5 days/week, 52 weeks/year. Capital Costs: Total capital cost S1,400,000 (1981...which makes their operating and maintenance costs, waste tonnages, ; and steam production readily available. Sample Data (All Numbers Rounded) 1st
Rakhmanin, Yu A; Levanchuk, A V
The paper presents the results of a study of the qualitative composition and quantity of pollutants in atmospheric air in the course of operational wear of the road surface, braking system and tire treads of automobiles. On the basis of field research in samples ofatmospheric air ofthe city of St. Petersburg there were identified compounds of heavy metals andpolycyclic aromatic hydrocarbons (PAHs). There was established the dependence of the level of air pollution on traffic flows in locations of the city. Pollutants were shown to enter the air environment mainly in the form offine dust particles. There was justified the need for the control ofproducts of wear the road traffic complex in the hygienic assessment of the quality of ambient air ofmegalopises.
Aerosol Sampling Experiment on the International Space Station
NASA Technical Reports Server (NTRS)
Meyer, Marit E.
2017-01-01
The International Space Station (ISS) is a unique indoor environment which serves as both home and workplace to the astronaut crew. There is currently no particulate monitoring, although particulate matter requirements exist. An experiment to collect particles in the ISS cabin was conducted recently. Two different aerosol samplers were used for redundancy and to collect particles in two size ranges spanning from 10 nm to hundreds of micrometers. The Active Sampler is a battery operated thermophoretic sampler with an internal pump which draws in air and collects particles directly on a transmission electron microscope grid. This commercial-off-the-shelf device was modified for operation in low gravity. The Passive Sampler has five sampling surfaces which were exposed to air for different durations in order to collect at least one sample with an optimal quantity of particles for microscopy. These samples were returned to Earth for analysis with a variety of techniques to obtain long-term average concentrations and identify particle emission sources. Results are compared with the inventory of ISS aerosols which was created based on sparse data and the literature. The goal of the experiment is to obtain data on indoor aerosols on ISS for future particulate monitor design and development.
Air and water quality monitor assessment of life support subsystems
NASA Technical Reports Server (NTRS)
Whitley, Ken; Carrasquillo, Robyn L.; Holder, D.; Humphries, R.
1988-01-01
Preprotype air revitalization and water reclamation subsystems (Mole Sieve, Sabatier, Static Feed Electrolyzer, Trace Contaminant Control, and Thermoelectric Integrated Membrane Evaporative Subsystem) were operated and tested independently and in an integrated arrangement. During each test, water and/or gas samples were taken from each subsystem so that overall subsystem performance could be determined. The overall test design and objectives for both subsystem and integrated subsystem tests were limited, and no effort was made to meet water or gas specifications. The results of chemical analyses for each of the participating subsystems are presented along with other selected samples which were analyzed for physical properties and microbiologicals.
Emission measurements for a lean premixed propane/air system at pressures up to 30 atmospheres
NASA Technical Reports Server (NTRS)
Roffe, G.; Venkataramani, K. S.
1978-01-01
The emissions of a lean premixed system of propane/air were measured in a flametube apparatus. Tests were conducted at inlet temperatures of 600K and 800K and pressures of 10 atm and 30 atm over a range of equivalence ratios. The data obtained were combined with previous data taken in the same apparatus to correlate nitrogen oxide emissions with operating conditions. Sampling probe design was found to have a pronounced effect on measured CO levels but did not influence measurements. The most effective probe tested was one which combined thermal and pressure quenching of the gas sample.
Evaluation of Sampling Methods for Bacillus Spore ...
Journal Article Following a wide area release of biological materials, mapping the extent of contamination is essential for orderly response and decontamination operations. HVAC filters process large volumes of air and therefore collect highly representative particulate samples in buildings. HVAC filter extraction may have great utility in rapidly estimating the extent of building contamination following a large-scale incident. However, until now, no studies have been conducted comparing the two most appropriate sampling approaches for HVAC filter materials: direct extraction and vacuum-based sampling.
Dunn, Kevin H.; Tsai, Candace Su-Jung; Woskie, Susan R.; Bennett, James S.; Garcia, Alberto; Ellenbecker, Michael J.
2015-01-01
The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 feet/minute) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust air flows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity. PMID:25175285
Index mismatch aberration correction over long working distances using spatial light modulation.
Gjonaj, Bergin; Johnson, Patrick; Bonn, Mischa; Domke, Katrin F
2012-11-20
For many microscopy applications, millimeters-long free working distances (LWD) are required. However, the high resolution and contrast of LWD objectives operated in air are lost when introducing glass and/or liquid with the sample. We propose to use spatial light modulation to correct for such beam aberrations caused by refractive index mismatches. Focusing a monochromatic laser beam with a 10 mm working distance air objective (50×, 0.5 NA) through air, glass, and water, we manage to restore a sharp, intense focus (FWHM<2λ) by adaptive beam phase shaping. Our approach offers a practical and cost-effective route to high resolution and contrast microscopy using LWD air objectives, extending their usage beyond applications in air.
Parvizi, Javad; Barnes, Sue; Shohat, Noam; Edmiston, Charles E
2017-11-01
In the modern operating room (OR), traditional surgical mask, frequent air exchanges, and architectural barriers are viewed as effective in reducing airborne microbial populations. Intraoperative sampling of airborne particulates is rarely performed in the OR because of technical difficulties associated with sampling methodologies and a common belief that airborne contamination is infrequently associated with surgical site infections (SSIs). Recent studies suggest that viable airborne particulates are readily disseminated throughout the OR, placing patients at risk for postoperative SSI. In 2017, virtually all surgical disciplines are engaged in the implantation of selective biomedical devices, and these implants have been documented to be at high risk for intraoperative contamination. Approximately 1.2 million arthroplasties are performed annually in the United States, and that number is expected to increase to 3.8 million by the year 2030. The incidence of periprosthetic joint infection is perceived to be low (<2.5%); however, the personal and fiscal morbidity is significant. Although the pharmaceutic and computer industries enforce stringent air quality standards on their manufacturing processes, there is currently no U.S. standard for acceptable air quality within the OR environment. This review documents the contribution of air contamination to the etiology of periprosthetic joint infection, and evidence for selective innovative strategies to reduce the risk of intraoperative microbial aerosols. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
14 CFR 298.52 - Air taxi operations by commuter air carriers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Air taxi operations by commuter air... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Commuter Air Carrier Authorizations § 298.52 Air taxi operations by commuter air carriers. (a) A commuter...
14 CFR 298.52 - Air taxi operations by commuter air carriers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Air taxi operations by commuter air... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Commuter Air Carrier Authorizations § 298.52 Air taxi operations by commuter air carriers. (a) A commuter...
14 CFR 298.52 - Air taxi operations by commuter air carriers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Air taxi operations by commuter air... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Commuter Air Carrier Authorizations § 298.52 Air taxi operations by commuter air carriers. (a) A commuter...
14 CFR 298.52 - Air taxi operations by commuter air carriers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Air taxi operations by commuter air... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Commuter Air Carrier Authorizations § 298.52 Air taxi operations by commuter air carriers. (a) A commuter...
14 CFR 298.52 - Air taxi operations by commuter air carriers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Air taxi operations by commuter air... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Commuter Air Carrier Authorizations § 298.52 Air taxi operations by commuter air carriers. (a) A commuter...
Improved Atmospheric Sampling of Hexavalent Chromium
Torkmahalleh, Mehdi Amouei; Yu, Chang-Ho; Lin, Lin; Fan, Zhihua (Tina); Swift, Julie L.; Bonanno, Linda; Rasmussen, Don H.; Holsen, Thomas M.; Hopke, Philip K.
2015-01-01
Hexavalent chromium (Cr(VI)) and trivalent chromium (Cr(III)) are the primary chromium oxidation states found in ambient atmospheric particulate matter. While Cr(III) is relatively nontoxic, Cr(VI) is toxic and exposure to Cr(VI) may lead to cancer, nasal damage, asthma, bronchitis, and pneumonitis. Accurate measurement of the ambient Cr(VI) concentrations is an environmental challenge since Cr(VI) can be reduced to Cr(III) and vice versa during sampling. In the present study, a new Cr(VI) sampler (Clarkson sampler) was designed, constructed, and field tested to improve the sampling of Cr(VI) in ambient air. The new Clarkson Cr(VI) sampler was based on the concept that deliquescence during sampling leads to aqueous phase reactions. Thus, the relative humidity of the sampled air was reduced below the deliquescence relative humidity (DRH) of the ambient particles. The new sampler was operated to collect Total Suspended Particles (TSP), and compared side-by-side with the current National Air Toxics Trends Stations (NATTS) Cr(VI) sampler that is utilized in the United States Environmental Protection Agency (USEPA) air toxics monitoring program. Side-by-side field testing of the samplers occurred in Elizabeth, NJ during the winter and summer of 2012. The average recovery values of Cr(VI) spikes after 24 hour sampling intervals during summer and winter sampling were 57 and 72%, respectively, for the Clarkson sampler, while the corresponding average values for NATTS samplers were 46% for both summer and winter sampling, respectively. Preventing the ambient aerosol collected on the filters from deliquescing is a key to improving the sampling of Cr(VI). PMID:24344574
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steele, W.J.; Williamson, A.D.; McCain, J.D.
1988-04-01
The report describes a transportable sampling apparatus designed to sample incineration sources at municipal and hazardous-waste disposal facilities, and to provide non-contaminated samples of condensable materials. The sample gas, at a flow rate of 10 cubic feet per minute (c f/m), passes through a modified Source Assessment Sampling System (SASS) cyclone and is then diluted with clean air at 100 cf/m by a novel, perforated cone assembly. Rapid uniform dilution takes place through the vigorous mixing of the sample and clean air streams in the dilution chamber. The resultant gas, cooled to about atmospheric conditions, is passed through a mixingmore » section that provides a residence time of about 3 seconds. The resulting aerosol particles are collected on a Teflon-coated glass-fiber filter. These solids, along with those collected in the cyclone, are subsequently provided for chemical and biological assay analysis.« less
Whole Air Sampling During NASA's March-April 1999 Pacific Exploratory Expedition (PEM-Tropics B)
NASA Technical Reports Server (NTRS)
Blake, Donald R.
2001-01-01
University of California, Irvine (UCI) collected more than 4500 samples whole air samples collected over the remote Pacific Ocean during NASA's Global Tropospheric Experiment (GTE) Pacific Exploratory Mission-Tropics B (PEM-Tropics B) in March and early April 1999. Approximately 140 samples during a typical 8-hour DC-8 flight, and 120 canisters for each 8-hour flight aboard the P-3B. These samples were obtained roughly every 3-7 min during horizontal flight legs and 1-3 min during vertical legs. The filled canisters were analyzed in the laboratory at UCI within ten days of collection. The mixing ratios of 58 trace gases comprising hydrocarbons, halocarbons, alkyl nitrates and DMS were reported (and archived) for each sample. Two identical analytical systems sharing the same standards were operated simultaneously around the clock to improve canister turn-around time and to keep our measurement precision optimal. This report presents a summary of the results for sample collected.
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
40 CFR 141.802 - Coliform sampling plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 141.802 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Aircraft Drinking Water Rule § 141.802 Coliform... aircraft water system owned or operated by the air carrier that identifies the following: (1) Coliform...
Juillet, Y; Dubois, C; Bintein, F; Dissard, J; Bossée, A
2014-08-01
A new rapid, sensitive and reliable method was developed for the determination of phosgene in air samples using thermal desorption (TD) followed by gas chromatography-mass spectrometry (GC-MS). The method is based on a fast (10 min) active sampling of only 1 L of air onto a Tenax® GR tube doped with 0.5 mL of derivatizing mixture containing dimercaptotoluene and triethylamine in hexane solution. Validation of the TD-GC-MS method showed a low limit of detection (40 ppbv), acceptable repeatability, intermediate fidelity (relative standard deviation within 12 %) and excellent accuracy (>95%). Linearity was demonstrated for two concentration ranges (0.04 to 2.5 ppmv and 2.5 to 10 ppmv) owing to variation of derivatization recovery between low and high concentration levels. Due to its simple on-site implementation and its close similarity with recommended operating procedure (ROP) for chemical warfare agents vapour sampling, the method is particularly useful in the process of verification of the Chemical Weapons Convention.
Bias of Tedlar bags in the measurement of agricultural odorants.
Trabue, Steven L; Anhalt, Jennifer C; Zahn, James A
2006-01-01
Odor regulations typically specify the use of dynamic dilution olfactometery (DDO) as a method to quantify odor emissions, and Tedlar bags are the preferred holding container for grab samples. This study was conducted to determine if Tedlar bags affect the integrity of sampled air from animal operations. Air samples were collected simultaneously in both Tedlar bags and Tenax thermal desorption tubes. Sample sources originated from either a hydrocarbon-free air tank, dynamic headspace chamber (DHC), or swine-production facility, and were analyzed by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). Several background contaminants were identified from Tedlar bags, which included the odorous compounds N,N-dimethyl acetamide (DMAC), acetic acid, and phenol. Samples from the DHC demonstrated that recovery of malodor compounds was dependent on residence time in the Tedlar bag with longer residence time leading to lower recovery. After 24 h of storage, recovery of C3-C6 volatile fatty acids (VFA) averaged 64%, 4-methylphenol and 4-ethylphenol averaged 10%, and indole and 3-methylindole were below the detection limits of GC-MS-O. The odor activity value (OAV) of grab samples collected in Tedlar bags were 33 to 65% lower following 24 h of storage. These results indicate that significant odorant bias occurs when using Tedlar bags for the sampling of odors from animal production facilities.
NASA Astrophysics Data System (ADS)
Baker, A. K.; Brenninkmeijer, C. A.; Oram, D. E.; O'Sullivan, D. A.; Slemr, F.; Schuck, T. J.
2009-12-01
The CARIBIC project (Civil Aircraft for the Regular Investigation of the atmosphere Based on an Instrument Container) involves the monthly deployment of an instrument container equipped to make atmospheric measurements from aboard a commercial airliner, and has operated since 2005 from aboard a Lufthansa Airbus 340-600 . Measurements from the container include in-situ trace gas and aerosol analyses and the collection of aerosol and whole air samples for post-flight laboratory analysis. Measurements made from the sampling flasks include greenhouse gas (GHG), halocarbon and nonmethane hydrocarbon (NMHC) analysis. CARIBIC flights originate in Frankfurt, Germany with routes to India, East Asia, South America, North America and Africa, and typical aircraft cruising altitudes of 10-12km allow for the monitoring of the upper troposphere/lower stratosphere (UT/LS) along these routes. Data collected during the aircraft’s departure from and return to Frankfurt provide a 4 year time series of near-monthly measurements of the composition of the UT/LS above Europe. Here we present a discussion of the composition of short-lived trace gases in the whole air samples collected above Europe during CARIBIC flights. Over 150 air samples were collected between May 2005 and July 2009, or about 4 samples per month. Of the whole air samples collected, about 45% showed influence by stratospheric air (i.e. very low values of GHG, NMHC and halocarbons, elevated O3, high potential vorticity). The remaining samples were representative of the upper troposphere; back trajectories for these samples indicate that a little over half were collected in air masses that had been in the boundary layer within the previous 8 days. The predominant source regions for these samples were the Gulf of Mexico and continental North America. Owing to their wide range of chemical lifetimes and the varying composition of emissions, short-lived trace gases transported to the UT/LS can be useful indicators of source region, photochemical processing and transport timescales of an air mass. Seasonal and longer-term trends in trace gases and trace gas composition are discussed, as well as composition of air masses having different origins. Additionally, we apply relationships between the different species, particularly the NMHC, to gain a qualitative understanding of photochemical processes occurring during transport from the boundary layer to the upper troposphere over Europe.
Tritium environmental transport studies at TFTR
NASA Astrophysics Data System (ADS)
Ritter, P. D.; Dolan, T. J.; Longhurst, G. R.
1993-06-01
Environmental tritium concentrations will be measured near the Tokamak Fusion Test Reactor (TFTR) to help validate dynamic models of tritium transport in the environment. For model validation the database must contain sequential measurements of tritium concentrations in key environmental compartments. Since complete containment of tritium is an operational goal, the supplementary monitoring program should be able to glean useful data from an unscheduled acute release. Portable air samplers will be used to take samples automatically every 4 hours for a week after an acute release, thus obtaining the time resolution needed for code validation. Samples of soil, vegetation, and foodstuffs will be gathered daily at the same locations as the active air monitors. The database may help validate the plant/soil/air part of tritium transport models and enhance environmental tritium transport understanding for the International Thermonuclear Experimental Reactor (ITER).
Characterization of 41Ar production in air at a PET cyclotron facility
NASA Astrophysics Data System (ADS)
Cicoria, Gianfranco; Cesarini, Francesco; Infantino, Angelo; Vichi, Sara; Zagni, Federico; Marengo, Mario
2017-06-01
In the production of Positron Emission Tomography (PET) nuclides at a medical cyclotron facility 41Ar (T1/2 = 109.34 m) is produced by the activation of air due to the neutron flux, according to the 40Ar(n, γ)41Ar reaction. In this work, we describe a relatively inexpensive and readily reproducible methodology of air sampling that can be used for quantification of 41Ar during the routine production of PET nuclides. We report the results of an extensive measurement campaign in the cyclotron bunker and in the ducts of the ventilation system, before and after final filtering of the extracted air. Air Samples were analyzed using a gamma-ray spectrometry system equipped with HPGe detector, with proper correction of the efficiency calibration to account for the samples density. The results of measurement were then used to evaluate the Total Effective Dose (TED) to the population living in the surrounding areas, due to routine emissions in the operation of the cyclotron. The average 41Ar saturation yield per one liter of air emitted in the environment resulted to be (0.044 ± 0.007) Bq/(μA ṡ dm3). The maximum value of TED for the critical group of the population, even considering an overestimated workload, was less than 0.19 μSv/year, well below the level of radiological relevance.
Human factors in air traffic control: problems at the interfaces.
Shouksmith, George
2003-10-01
The triangular ISIS model for describing the operation of human factors in complex sociotechnical organisations or systems is applied in this research to a large international air traffic control system. A large sample of senior Air Traffic Controllers were randomly assigned to small focus discussion groups, whose task was to identify problems occurring at the interfaces of the three major human factor components: individual, system impacts, and social. From these discussions, a number of significant interface problems, which could adversely affect the functioning of the Air Traffic Control System, emerged. The majority of these occurred at the Individual-System Impact and Individual-Social interfaces and involved a perceived need for further interface centered training.
NASA Astrophysics Data System (ADS)
Gullett, Brian; Touati, Abderrahmane; Oudejans, Lukas
Emissions of aromatic air toxics from aircraft ground equipment (AGE) were measured with a resonance enhanced multiphoton ionization-time of flight mass spectrometry (REMPI-TOFMS) system consisting of a pulsed solid state laser for photoionization and a TOFMS for mass discrimination. This instrument was capable of characterizing turbine emissions and the effect of varying load operations on pollutant production. REMPI-TOFMS is capable of high selectivity and low detection limits (part per trillion to part per billion) in real time (1 s resolution). Hazardous air pollutants and criteria pollutants were measured during startups and idle and full load operations. Measurements of compounds such as benzene, toluene, ethylbenzene, xylenes, styrene, and polycyclic aromatic hydrocarbons compared well with standard methods. Startup emissions from the AGE data showed persistent concentrations of pollutants, unlike those from a diesel generator, where a sharp spike in emissions rapidly declined to steady state levels. The time-resolved responses of air toxics concentrations varied significantly by source, complicating efforts to minimize these emissions with common operating prescriptions. The time-resolved measurements showed that pollutant concentrations decline (up to 5×) in a species-specific manner over the course of multiple hours of operation, complicating determination of accurate and precise emission factors via standard extractive sampling. Correlations of air toxic concentrations with more commonly measured pollutants such as CO or PM were poor due to the relatively greater changes in the measured toxics' concentrations.
Cheng, Lei; Wu, Cheng Hao; Jarry, Angelique; Chen, Wei; Ye, Yifan; Zhu, Junfa; Kostecki, Robert; Persson, Kristin; Guo, Jinghua; Salmeron, Miquel; Chen, Guoying; Doeff, Marca
2015-08-19
The interfacial resistances of symmetrical lithium cells containing Al-substituted Li7La3Zr2O12 (LLZO) solid electrolytes are sensitive to their microstructures and histories of exposure to air. Air exposure of LLZO samples with large grain sizes (∼150 μm) results in dramatically increased interfacial impedances in cells containing them, compared to those with pristine large-grained samples. In contrast, a much smaller difference is seen between cells with small-grained (∼20 μm) pristine and air-exposed LLZO samples. A combination of soft X-ray absorption (sXAS) and Raman spectroscopy, with probing depths ranging from nanometer to micrometer scales, revealed that the small-grained LLZO pellets are more air-stable than large-grained ones, forming far less surface Li2CO3 under both short- and long-term exposure conditions. Surface sensitive X-ray photoelectron spectroscopy (XPS) indicates that the better chemical stability of the small-grained LLZO is related to differences in the distribution of Al and Li at sample surfaces. Density functional theory calculations show that LLZO can react via two different pathways to form Li2CO3. The first, more rapid, pathway involves a reaction with moisture in air to form LiOH, which subsequently absorbs CO2 to form Li2CO3. The second, slower, pathway involves direct reaction with CO2 and is favored when surface lithium contents are lower, as with the small-grained samples. These observations have important implications for the operation of solid-state lithium batteries containing LLZO because the results suggest that the interfacial impedances of these devices is critically dependent upon specific characteristics of the solid electrolyte and how it is prepared.
Hydrocarbon emissions in the Bakken oil field in North Dakota
NASA Astrophysics Data System (ADS)
Mielke-Maday, I.; Petron, G.; Miller, B.; Frost, G. J.; Peischl, J.; Kort, E. A.; Smith, M. L.; Karion, A.; Dlugokencky, E. J.; Montzka, S. A.; Sweeney, C.; Ryerson, T. B.; Tans, P. P.; Schnell, R. C.
2014-12-01
Within the past five years, the production of oil and natural gas in the United States from tight formations has increased rapidly due to advances in technology, such as horizontal drilling and hydraulic fracturing. With the expansion of oil and natural gas extraction operations comes the need to better quantify their emissions and potential impacts on climate forcing and air quality. The Bakken formation within the Williston Basin in North Dakota has emerged as a large contributor to the recent growth in oil production and accounts for over 10% of domestic production. Close to 30% of associated gas co-produced with the oil is flared. Very little independent information is currently available to assess the oil and gas industry emissions and their impacts on regional air quality. In May 2014, an airborne field campaign was conducted by the National Oceanic and Atmospheric Administration's (NOAA) Earth System Research Laboratory and the University of Michigan to investigate hydrocarbon emissions from operations in the oil field. Here, we present results from the analysis for methane, several non-methane hydrocarbons and combustion tracers in 72 discrete air samples collected by the aircraft on nine different flights. Samples were obtained in the boundary layer upwind and downwind of the operations and in the free troposphere. We will show results of a multiple species analysis and compare them with field campaign data from other U.S. oil and gas fields, measurements from NOAA's Global Monitoring Division long-term observing network, and available bottom-up information on emissions from oil and gas operations.
Sorption of atmospheric gases by bulk lithium metal
Hart, C. A.; Skinner, C. H.; Capece, A. M.; ...
2016-01-01
Lithium conditioning of plasma facing components has enhanced the performance of several fusion devices. Elemental lithium will react with air during maintenance activities and with residual gases (H 2O, CO, CO 2) in the vacuum vessel during operations. We have used a mass balance (microgram sensitivity) to measure the mass gain of lithium samples during exposure of a ~1 cm 2 surface to ambient and dry synthetic air. For ambient air, we found an initial mass gain of several mg/h declining to less than 1 mg/h after an hour and decreasing by an order of magnitude after 24 h. Amore » 9 mg sample achieved a final mass gain corresponding to complete conversion to Li 2CO 3 after 5 days. Exposure to dry air resulted in a 30 times lower initial rate of mass gain. The results have implications for the chemical state of lithium plasma facing surfaces and for safe handling of lithium coated components.« less
Atomic resolution images of graphite in air
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grigg, D.A.; Shedd, G.M.; Griffis, D.
One sample used for proof of operation for atomic resolution in STM is highly oriented pyrolytic graphite (HOPG). This sample has been imaged with many different STM`s obtaining similar results. Atomic resolution images of HOPG have now been obtained using an STM designed and built at the Precision Engineering Center. This paper discusses the theoretical predictions and experimental results obtained in imaging of HOPG.
40 CFR 63.364 - Monitoring requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES Ethylene Oxide Emissions.... (2) Each owner or operator of an ethylene oxide sterilization facility subject to these emissions...: (1) Sample the scrubber liquor and analyze and record once per week the ethylene glycol concentration...
Krajewski, Wojciech; Kucharska, Malgorzata; Wesolowski, Wiktor; Stetkiewicz, Jan; Wronska-Nofer, Teresa
2007-03-01
The aim of this study was to assess the level of occupational exposure to nitrous oxide (N(2)O) in operating rooms (ORs), as related to different ventilation and scavenging systems used to remove waste anaesthetic gases from the work environment. The monitoring of N(2)O in the air covered 35 ORs in 10 hospitals equipped with different systems for ventilation and anaesthetic scavenging. The examined systems included: natural ventilation with supplementary fresh air provided by a pressure ventilation system (up to 6 air changes/h); pressure and exhaust ventilation systems equipped with ventilation units supplying fresh air to and discharging contaminated air outside the working area (more than 10 air changes/h); complete air-conditioning system with laminar air flow (more than 15 air changes/h). The measurements were carried out during surgical procedures (general anaesthesia induced intravenously and maintained with inhaled N(2)O and sevofluran delivered through cuffed endotracheal tubes) with connected or disconnected air scavenging. Air was collected from the breathing zone of operating personnel continuously through the whole time of anaesthesia to Tedlar((R)) bags, and N(2)O concentrations in air samples were analyzed by adsorption gas chromatography/mass spectrometry. N(2)O levels in excess of the occupational exposure limit (OEL) value of 180mg/m(3) were registered in all ORs equipped with ventilation systems alone. The OEL value was exceeded several times in rooms with natural ventilation plus supplementary pressure ventilations and twice or less in those with pressure/exhaust ventilation systems or air conditioning. N(2)O levels below or within the OEL value were observed in rooms where the system of air conditioning or pressure/exhaust ventilation was combined with scavenging systems. Systems combining natural/pressure ventilation with scavenging were inadequate to maintain N(2)O concentration below the OEL value. Air conditioning and an efficient pressure/exhaust ventilation (above 12 air exchanges/h) together with efficient active scavenging systems are sufficient to sustain N(2)O exposure in ORs at levels below or within the OEL value of 180mg/m(3).
Kim, Sung-Han; Chang, So Young; Sung, Minki; Park, Ji Hoon; Bin Kim, Hong; Lee, Heeyoung; Choi, Jae-Phil; Choi, Won Suk; Min, Ji-Young
2016-08-01
The largest outbreak of Middle East respiratory syndrome coronavirus (MERS-CoV) outside the Middle East occurred in South Korea in 2015 and resulted in 186 laboratory-confirmed infections, including 36 (19%) deaths. Some hospitals were considered epicenters of infection and voluntarily shut down most of their operations after nearly half of all transmissions occurred in hospital settings. However, the ways that MERS-CoV is transmitted in healthcare settings are not well defined. We explored the possible contribution of contaminated hospital air and surfaces to MERS transmission by collecting air and swabbing environmental surfaces in 2 hospitals treating MERS-CoV patients. The samples were tested by viral culture with reverse transcription polymerase chain reaction (RT-PCR) and immunofluorescence assay (IFA) using MERS-CoV Spike antibody, and electron microscopy (EM). The presence of MERS-CoV was confirmed by RT-PCR of viral cultures of 4 of 7 air samples from 2 patients' rooms, 1 patient's restroom, and 1 common corridor. In addition, MERS-CoV was detected in 15 of 68 surface swabs by viral cultures. IFA on the cultures of the air and swab samples revealed the presence of MERS-CoV. EM images also revealed intact particles of MERS-CoV in viral cultures of the air and swab samples. These data provide experimental evidence for extensive viable MERS-CoV contamination of the air and surrounding materials in MERS outbreak units. Thus, our findings call for epidemiologic investigation of the possible scenarios for contact and airborne transmission, and raise concern regarding the adequacy of current infection control procedures. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Personal exposure to JP-8 jet fuel vapors and exhaust at air force bases.
Pleil, J D; Smith, L B; Zelnick, S D
2000-01-01
JP-8 jet fuel (similar to commercial/international jet A-1 fuel) is the standard military fuel for all types of vehicles, including the U.S. Air Force aircraft inventory. As such, JP-8 presents the most common chemical exposure in the Air Force, particularly for flight and ground crew personnel during preflight operations and for maintenance personnel performing routine tasks. Personal exposure at an Air Force base occurs through occupational exposure for personnel involved with fuel and aircraft handling and/or through incidental exposure, primarily through inhalation of ambient fuel vapors. Because JP-8 is less volatile than its predecessor fuel (JP-4), contact with liquid fuel on skin and clothing may result in prolonged exposure. The slowly evaporating JP-8 fuel tends to linger on exposed personnel during their interaction with their previously unexposed colleagues. To begin to assess the relative exposures, we made ambient air measurements and used recently developed methods for collecting exhaled breath in special containers. We then analyzed for certain volatile marker compounds for JP-8, as well as for some aromatic hydrocarbons (especially benzene) that are related to long-term health risks. Ambient samples were collected by using compact, battery-operated, personal whole-air samplers that have recently been developed as commercial products; breath samples were collected using our single-breath canister method that uses 1-L canisters fitted with valves and small disposable breathing tubes. We collected breath samples from various groups of Air Force personnel and found a demonstrable JP-8 exposure for all subjects, ranging from slight elevations as compared to a control cohort to > 100 [mutilpe] the control values. This work suggests that further studies should be performed on specific issues to obtain pertinent exposure data. The data can be applied to assessments of health outcomes and to recommendations for changes in the use of personal protective equipment that optimize risk reduction without undue impact on a mission. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 PMID:10706522
The first survey of airborne trace elements at airport using moss bag technique.
Vuković, Gordana; Urošević, Mira Aničić; Škrivanj, Sandra; Vergel, Konstantin; Tomašević, Milica; Popović, Aleksandar
2017-06-01
Air traffic represents an important way of social mobility in the world, and many ongoing discussions are related to the impacts that air transportation has on local air quality. In this study, moss Sphagnum girgensohnii was used for the first time in the assessment of trace element content at the international airport. The moss bags were exposed during the summer of 2013 at four sampling sites at the airport 'Nikola Tesla' (Belgrade, Serbia): runway (two), auxiliary runway and parking lot. According to the relative accumulation factor (RAF) and the limit of quantification of the moss bag technique (LOQ T ), the most abundant elements in the samples were Zn, Na, Cr, V, Cu and Fe. A comparison between the element concentrations at the airport and the corresponding values in different land use classes (urban central, suburban, industrial and green zones) across the city of Belgrade did not point out that the air traffic and associated activities significantly contribute to the trace element air pollution. This study emphasised an easy operational and robust (bio)monitoring, using moss bags as a suitable method for assessment of air quality within various microenvironments with restriction in positioning referent instrumental devices.
Witschger, O; Grinshpun, S A; Fauvel, S; Basso, G
2004-06-01
While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the dust source, faces the source. Thus, the first objective of this study was to design and test a new, low cost experimental protocol for measuring the sampling efficiency of personal inhalable aerosol samplers in the vicinity of the aerosol source when the samplers operate in very slowly moving air. In this system, an aerosol generator, which is located in the centre of a room-sized non-ventilated chamber, continuously rotates and omnidirectionally disperses test particles of a specific size. The test and reference samplers are equally distributed around the source at the same distance from the centre and operate in parallel (in most of our experiments, the total number of simultaneously operating samplers was 15). Radial aerosol transport is driven by turbulent diffusion and some natural convection. For each specific particle size and the sampler, the aerosol mass concentration is measured by weighing the collection filter. The second objective was to utilize the new protocol to evaluate three widely used aerosol samplers: the IOM Personal Inhalable Sampler, the Button Personal Inhalable Aerosol Sampler and the 25 mm Millipore filter holder (closed-face C25 cassette). The sampling efficiencies of each instrument were measured with six particle fractions, ranging from 6.9 to 76.9 micro m in their mass median aerodynamic diameter. The Button Sampler efficiency data demonstrated a good agreement with the standard inhalable convention and especially with the low air movement inhalabilty curve. The 25 mm filter holder was found to considerably under-sample the particles larger than 10 micro m; its efficiency did not exceed 7% for particles of 40-100 micro m. The IOM Sampler facing the source was found to over-sample compared with the data obtained previously with a slowly rotating, freely suspended sampler in a low air movement environment. It was also found that the particle wall deposition in the IOM metallic cartridge was rather significant and particle size-dependent. For each sampler (IOM, Button and C25) the precision was characterized through the relative standard deviation (RSD) of the aerosol concentration obtained with identical samplers in a specific experiment. The average RSD was 14% for the IOM Sampler, 11% for the Button Sampler and 35% for the 25 mm filter cassette. A separate set of experiments, performed with the Simplified Torso showed that in very slowly moving air a personal sampler can be adequately evaluated even when it is not attached to a body but freely suspended (confirming the data reported previously).
Compendium of Operations Research and Economic Analysis Studies.
1987-09-01
robots , conveyor belts, etc. are modeled as well. Simulation results indicate that the IMC design for receiving and packing is feasible from a system...Logistics Services Center (DLSC) operation. Benef its were evaluated through analysis of a sample of data from recipients as to the use being made of...Modernization of the DPSC Manufacturing Facility (August 1969) This study explored the feasibility of a proposal to air condition and modernize the
A black carbon air quality network
NASA Astrophysics Data System (ADS)
Kirchstetter, T.; Caubel, J.; Cados, T.; Preble, C.; Rosen, A.
2016-12-01
We developed a portable, power efficient black carbon sensor for deployment in an air quality network in West Oakland, California. West Oakland is a San Francisco Bay Area residential/industrial community adjacent to regional port and rail yard facilities, and is surrounded by major freeways. As such, the community is affected by diesel particulate matter emissions from heavy-duty diesel trucks, locomotives, and ships associated with freight movement. In partnership with Environmental Defense Fund, the Bay Area Air Quality Management District, and the West Oakland Environmental Indicators Project, we are collaborating with community members to build and operate a 100-sensor black carbon measurement network for a period of several months. The sensor employs the filter-based light transmission method to measure black carbon. Each sensor node in the network transmits data hourly via SMS text messages. Cost, power consumption, and performance are considered in choosing components (e.g., pump) and operating conditions (e.g., sample flow rate). In field evaluation trials over several weeks at three monitoring locations, the sensor nodes provided black carbon concentrations comparable to commercial instruments and ran autonomously for a week before sample filters and rechargeable batteries needed to be replaced. Buildup to the 100-sensor network is taking place during Fall 2016 and will overlap with other ongoing air monitoring projects and monitoring platforms in West Oakland. Sensors will be placed along commercial corridors, adjacent to freeways, upwind of and within the Port, and throughout the residential community. Spatial and temporal black carbon concentration patterns will help characterize pollution sources and demonstrate the value of sensing networks for characterizing intra-urban air pollution concentrations and exposure to air pollution.
Dai, Chunyang; Zhang, Yan; Ma, Xiaoling; Yin, Meiling; Zheng, Haiyang; Gu, Xuejun; Xie, Shaoqing; Jia, Hengmin; Zhang, Liang; Zhang, Weijun
2015-01-01
Airborne bacterial contamination poses a risk for surgical site infection, and routine surveillance of airborne bacteria is important. Traditional methods for detecting airborne bacteria are time consuming and strenuous. Measurement of biologic particle concentrations using a fluorescent particle counter is a novel method for evaluating air quality. The current study was to determine whether the number of biologic particles detected by the fluorescent particle counter can be used to indicate airborne bacterial counts in operating rooms. The study was performed in an operating theater at a university hospital in Hefei, China. The number of airborne biologic particles every minute was quantified using a fluorescent particle counter. Microbiologic air sampling was performed every 30 minutes using an Andersen air sampler (Pusong Electronic Instruments, Changzhou, China). Correlations between the 2 different methods were analyzed by Pearson correlation coefficients. A significant correlation was observed between biologic particle and bacterial counts (Pearson correlation coefficient = 0.76), and the counting results from 2 methods both increased substantially between operations, corresponding with human movements in the operating room. Fluorescent particle counters show potential as important tools for monitoring bacterial contamination in operating theatres. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Self-contained cryogenic gas sampling apparatus and method
McManus, G.J.; Motes, B.G.; Bird, S.K.; Kotter, D.K.
1996-03-26
Apparatus for obtaining a whole gas sample, is composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method is described for obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant. 3 figs.
Self-contained cryogenic gas sampling apparatus and method
McManus, Gary J.; Motes, Billy G.; Bird, Susan K.; Kotter, Dale K.
1996-01-01
Apparatus for obtaining a whole gas sample, composed of: a sample vessel having an inlet for receiving a gas sample; a controllable valve mounted for controllably opening and closing the inlet; a valve control coupled to the valve for opening and closing the valve at selected times; a portable power source connected for supplying operating power to the valve control; and a cryogenic coolant in thermal communication with the vessel for cooling the interior of the vessel to cryogenic temperatures. A method of obtaining an air sample using the apparatus described above, by: placing the apparatus at a location at which the sample is to be obtained; operating the valve control to open the valve at a selected time and close the valve at a selected subsequent time; and between the selected times maintaining the vessel at a cryogenic temperature by heat exchange with the coolant.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.
The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less
Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; ...
2015-03-02
The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogatemore » measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.« less
Ramos, Tiffanie; Dedesko, Sandra; Siegel, Jeffrey A.; Gilbert, Jack A.; Stephens, Brent
2015-01-01
The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO2 concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ∼8×106 data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections. PMID:25729898
Wen, Dongqi; Zhai, Wenjuan; Xiang, Sheng; Hu, Zhice; Wei, Tongchuan; Noll, Kenneth E
2017-11-01
Determination of the effect of vehicle emissions on air quality near roadways is important because vehicles are a major source of air pollution. A near-roadway monitoring program was undertaken in Chicago between August 4 and October 30, 2014, to measure ultrafine particles, carbon dioxide, carbon monoxide, traffic volume and speed, and wind direction and speed. The objective of this study was to develop a method to relate short-term changes in traffic mode of operation to air quality near roadways using data averaged over 5-min intervals to provide a better understanding of the processes controlling air pollution concentrations near roadways. Three different types of data analysis are provided to demonstrate the type of results that can be obtained from a near-roadway sampling program based on 5-min measurements: (1) development of vehicle emission factors (EFs) for ultrafine particles as a function of vehicle mode of operation, (2) comparison of measured and modeled CO 2 concentrations, and (3) application of dispersion models to determine concentrations near roadways. EFs for ultrafine particles are developed that are a function of traffic volume and mode of operation (free flow and congestion) for light-duty vehicles (LDVs) under real-world conditions. Two air quality models-CALINE4 (California Line Source Dispersion Model, version 4) and AERMOD (American Meteorological Society/U.S. Environmental Protection Agency Regulatory Model)-are used to predict the ultrafine particulate concentrations near roadways for comparison with measured concentrations. When using CALINE4 to predict air quality levels in the mixing cell, changes in surface roughness and stability class have no effect on the predicted concentrations. However, when using AERMOD to predict air quality in the mixing cell, changes in surface roughness have a significant impact on the predicted concentrations. The paper provides emission factors (EFs) that are a function of traffic volume and mode of operation (free flow and congestion) for LDVs under real-world conditions. The good agreement between monitoring and modeling results indicates that high-resolution, simultaneous measurements of air quality and meteorological and traffic conditions can be used to determine real-world, fleet-wide vehicle EFs as a function of vehicle mode of operation under actual driving conditions.
Spatial analysis of volatile organic compounds in South Philadelphia using passive samplers
Select volatile organic compounds (VOCs) were measured in the vicinity of a petroleum refinery and related operations in South Philadelphia, Pennsylvania, USA, using passive air sampling and laboratory analysis methods. Two-week, time-integrated samplers were deployed at 17 sites...
40 CFR 141.804 - Aircraft water system operations and maintenance plan.
Code of Federal Regulations, 2013 CFR
2013-07-01
... must include the following requirements for procedures for disinfection and flushing of aircraft water system. (i) The air carrier must conduct disinfection and flushing of the aircraft water system in... water procedures; (ii) Sample collection procedures; (iii) Disinfection and flushing procedures; (iv...
Helicopter Operations and Personnel Safety (Helirescue Manual). Fourth Edition.
ERIC Educational Resources Information Center
Dalle-Molle, John
The illustrated manual includes information on various aspects of helicopter rescue missions, including mission management roles for key personnel, safety rules around helicopters, requests for helicopter support, sample military air support forms, selection of landing zones, helicopter evacuations, rescuer delivery, passenger unloading, crash…
Volatile Organic Analyzer (VOA) in 2006: Repair, Revalidation, and Restart of Elektron Event
NASA Technical Reports Server (NTRS)
Limero, Thomas
2007-01-01
The Volatile Organic Analyzer (VOA) was launched to the International Space Station (ISS) in August 2001 and was the first instrument to provide near real-time measurement of volatile organic compounds in a spacecraft atmosphere. The VOA performed an analysis of the ISS air approximately twice a month for most of its operation through May 2003. This intermittent operation, caused by a software interface issue with the ISS communication bus, slowed the validation of the VOA. However, operational validation was completed in 2003 when analysis of air samples collected in grab sample containers (GSCs) compared favorably with simultaneous VOA runs (1). The VOA has two channels that provide redundant function, albeit at slightly reduced performance, when only one channel is operating (2). Most target compounds can be detected on both channels. In January 2003, the VOA identified a malfunction in the channel 2 preconcentrator and it shut down that channel. The anomaly profile suggested that a fuse might have failed, but the root cause could not be determined. In May 2003, channel 1 was shut down when the detector s elevated temperature could not longer be maintained. Since both VOA channels were now deactivated, VOA operations ended until an in-flight repair could be planned and executed. This paper describes the process to repair the VOA and to revalidate it for operations, and then an account is given of the VOA s contribution following a contingency event on ISS.
AIRBORNE MICROORGANISMS IN BROILER PROCESSING PLANTS.
KOTULA, A W; KINNER, J A
1964-05-01
Concentrations of total aerobic bacteria, molds, yeasts, coliforms, enterococci, and psychrophiles were determined in the air of two poultry processing plants with Andersen samplers and a mobile power supply. Total aerobic bacterial counts were highest in the dressing room, with diminishing numbers in the shackling, eviscerating, and holding rooms, when sampling was carried out during plant operation. The average counts per ft(3) of air in these four rooms were 2,200; 560; 230; and 62, respectively. (Each value is the average of 36 observations.) The number of organisms increased in the shackling and dressing rooms once processing was begun. Average total aerobic bacterial counts increased from 70 to 870 to 3,000 in the shackling room and from 310 to 4,900 to 7,000 in the dressing room when sampling was carried out at 5:00 am (before plant operations), 9:00 am, and 2:00 pm, respectively. (Each value is the mean of 12 observations.) Airborne molds might originate from a source other than the poultry being processed.
Airborne Microorganisms in Broiler Processing Plants
Kotula, Anthony W.; Kinner, Jack A.
1964-01-01
Concentrations of total aerobic bacteria, molds, yeasts, coliforms, enterococci, and psychrophiles were determined in the air of two poultry processing plants with Andersen samplers and a mobile power supply. Total aerobic bacterial counts were highest in the dressing room, with diminishing numbers in the shackling, eviscerating, and holding rooms, when sampling was carried out during plant operation. The average counts per ft3 of air in these four rooms were 2,200; 560; 230; and 62, respectively. (Each value is the average of 36 observations.) The number of organisms increased in the shackling and dressing rooms once processing was begun. Average total aerobic bacterial counts increased from 70 to 870 to 3,000 in the shackling room and from 310 to 4,900 to 7,000 in the dressing room when sampling was carried out at 5:00 am (before plant operations), 9:00 am, and 2:00 pm, respectively. (Each value is the mean of 12 observations.) Airborne molds might originate from a source other than the poultry being processed. Images FIG. 3 PMID:14170951
14 CFR 294.3 - General requirements for Canadian charter air taxi operators.
Code of Federal Regulations, 2011 CFR
2011-01-01
... air taxi operators. 294.3 Section 294.3 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS CANADIAN CHARTER AIR TAXI OPERATORS General § 294.3 General requirements for Canadian charter air taxi operators. A Canadian charter air taxi operator shall...
14 CFR 294.3 - General requirements for Canadian charter air taxi operators.
Code of Federal Regulations, 2010 CFR
2010-01-01
... air taxi operators. 294.3 Section 294.3 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS CANADIAN CHARTER AIR TAXI OPERATORS General § 294.3 General requirements for Canadian charter air taxi operators. A Canadian charter air taxi operator shall...
The advantages and disadvantages of centralized control of air power at operational level
NASA Astrophysics Data System (ADS)
Arisoy, Uǧur
2014-05-01
People do not want to see and hear a war. In today's world, if war is inevitable, the use of air power is seen as the preferable means of conducting operations instead of financially burdensome land battles which are more likely to cause heavy loss of life. The use of Air Power has gained importance in NATO operations in the Post-Cold War era. For example, air power has undertaken a decisive role from the beginning to the end of the operation in Libya. From this point of view, the most important issue to consider is how to direct air power more effectively at operational level. NATO's Core JFAC (Joint Force Air Command) was established in 2012 to control joint air power at operational level from a single center. US had experienced JFAC aproach in the Operation Desert Storm in 1991. UK, France, Germany, Italy and Spain are also directing their air power from their JFAC structures. Joint air power can be directed from a single center at operational level by means of JFAC. JFAC aproach provides complex planning progress of Air Power to be controled faster in a single center. An Air Power with a large number of aircrafts, long range missiles of cutting-edge technology may have difficulties in achieving results unless directed effectively. In this article, directing air power more effectively at operational level has been studied in the framework of directing air power from a single center carried out by SWOT analysis technique. "Directing Air Power at operational level from a single center similar to JFAC-like structure" is compared with "Directing Air Power at operational level from two centers similar to AC (Air Command) + CAOC (Combined Air Operations Center) structure" As a result of this study, it is assessed that directing air power at operational level from a single center would bring effectiveness to the air campaign. The study examines directing air power at operational level. Developments at political, strategic and tactical levels have been ignored.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Swarin, S.J.; Loo, J.F.; Chladek, E.
1992-01-01
Analytical methods for determining individual aldehyde, ketone, and alcohol emissions from gasoline-, methanol-, and variable-fueled vehicles are described. These methods were used in the Auto/Oil Air Quality Improvement Research Program to provide emission data for comparison of individual reformulated fuels, individual vehicles, and for air modeling studies. The emission samples are collected in impingers which contain either 2,4-dinitrophenylhydrazine solution for the aldehydes and ketones or deionized water for the alcohols. Subsequent analyses by liquid chromatography for the aldehydes and ketones and gas chromatography for the alcohols utilized auto injectors and computerized data systems which permit high sample throughput with minimalmore » operator intervention. The quality control procedures developed and interlaboratory comparisons conducted as part of the program are also described. (Copyright (c) 1992 Society of Automotive Engineers, Inc.)« less
History of the Armed Services Vocational Aptitude Battery (ASVAB) 1974-1980
1980-03-01
the high school equivalent form to ASVAB-3 being used operationally by the Air Force and Marine Corps). A counterbalanced design , in ... , 11. ,,...National Lcartudinal Survev of Youth made use of three Independent probability samples. Two of these samples were designed to cover the non ...literacy, but non -language tests were also introduced for service qualifica- tion. After service entry, the primary test instruments for assignment
Mendez, Gregory O.; Foreman, William T.; Morita, Andrew; Majewski, Michael S.
2008-01-01
In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to monitor water, air, and sediment at the Sweetwater and Loveland Reservoirs in San Diego County, California. The study includes regular sampling of water and air at Sweetwater Reservoir for chemical constituents, including volatile organic compounds (VOC), polynuclear aromatic hydrocarbons (PAH), pesticides, and major and trace elements. The purpose of this study is to monitor changes in contaminant composition and concentration during the construction and operation of State Route 125. To accomplish this, the study was divided into two phases. Phase One sampling (water years 1998–2004) determined baseline conditions for the detection frequency and the concentrations of target compounds in air and water. Phase Two sampling (starting water year 2005) continues at selected monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment may have on water quality in the reservoir. Water samples were collected for VOCs and pesticides at Loveland Reservoir during Phase One and will be collected during Phase Two for comparison purposes. Air samples collected to monitor changes in VOCs, PAHs, and pesticides were analyzed by adapting methods used to analyze water samples. Bed-sediment samples have been and will be collected three times during the study; at the beginning of Phase One, at the start of Phase Two, and near the end of the study. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as trace metals, anthropogenic indicator compounds, and pharmaceuticals. This report describes the study design, and the sampling and analytical methods, and presents data from water and air samples collected during the fourth and fifth years of Phase One of the study (October 2001 to September 2003). Data collected during the first three years has been previously published. Three types of quality-control samples were used in this study: blanks, spikes, and replicates. Blanks and spikes are used to estimate result bias, and replicates are used to estimate result variability. Additionally, surrogate compounds were added at the laboratory to samples of VOCs, PAHs, pesticides, anthropogenic indicator compounds, and pharmaceuticals to monitor sample-specific performance of the analytical method.
Unanticipated potential cancer risk near metal recycling facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raun, Loren, E-mail: raun@rice.edu; Pepple, Karl, E-mail: pepple.karl@epa.gov; Hoyt, Daniel, E-mail: hoyt.daniel@epa.gov
2013-07-15
Metal recycling is an important growing industry. Prior to this study, area sources consisting of metal recycling facilities fell in a category of limited regulatory scrutiny because of assumed low levels of annual emissions. Initiating with community complaints of nuisance from smoke, dust and odor, the Houston Department of Health and Human Services (HDHHS) began a monitoring program outside metal recycler facilities and found metal particulates in outdoor ambient air at levels which could pose a carcinogenic human health risk. In a study of five similar metal recycler facilities which used a torch cutting process, air downwind and outside themore » facility was sampled for eight hours between 6 and 10 times each over 18 months using a mobile laboratory. Ten background locations were also sampled. Iron, manganese, copper, chromium, nickel, lead, cobalt, cadmium and mercury were detected downwind of the metal recyclers at frequencies ranging from 100% of the time for iron to 2% of the time for mercury. Of these metals, chromium, nickel, lead, cobalt, cadmium and mercury were not detected in any sample in the background. Two pairs of samples were analyzed for total chromium and hexavalent chromium to establish a ratio of the fraction of hexavalent chromium in total chromium. This fraction was used to estimate hexavalent chromium at all locations. The carcinogenic risk posed to a residential receptor from metal particulate matter concentrations in the ambient air attributed to the metal recyclers was estimated from each of the five facilities in an effort to rank the importance of this source and inform the need for further investigation. The total risk from these area sources ranged from an increased cancer risk of 1 in 1,000,000 to 6 in 10,000 using the 95th upper confidence limit of the mean of the carcinogenic metal particulate matter concentration, assuming the point of the exposure is the sample location for a residential receptor after accounting for wind direction and the number of shifts that could operate a year. Further study is warranted to better understand the metal air pollution levels in the community and if necessary, to evaluate the feasibility of emission controls and identify operational improvements and best management practices for this industry. This research adds two new aspects to the literature: identification of types and magnitude of metal particulate matter air pollutants associated with a previously unrecognized area source, metal recyclers and their potential risk to health. -- Highlights: • Air monitoring study in response to community complaints found metal contamination. • Metal recyclers found to potentially pose cancer from metal particulates • Chromium, nickel, cobalt and cadmium samples were detected in five metal recyclers. • These metals were not detected in background air samples. • Estimated increased cancer risk ranges from 1 in 1,000,000 to 8 in 10,000.« less
NASA Astrophysics Data System (ADS)
Studabaker, W. B.; Jayanty, J.; Raymer, J. H.; Krupa, S.
2013-12-01
As mining and refinery operations in the Alberta Oil Sands Region (AOSR) have expanded, there has been increasing concern for the impacts of air pollution generated by those operations on both human and ecosystem health. The inaccessibility of much of the AOSR makes it difficult to establish conventional air quality monitoring stations to the extent needed to model long-range impacts of emissions from the AOSR operations. Epiphytic lichens are important markers of ecosystem health, are well-established bioaccumulators of trace metals, and are potentially useful biomonitors of air pollution. However, their ability to take up organic pollutants has not been extensively explored, and only recently have they been used for biomonitoring of pollution by PAHs. Here we describe the determination of polynuclear aromatic hydrocarbons (PAHs) in lichens, collected from sites throughout the AOSR, for modeling emissions associated with mining and oil extraction operations. We also describe preliminary results of the determination of PAHs in PM 2.5 filters from dichotomous samplers stationed in the AOSR, in the context of the biological sample data. Lichens (Hypogymnia physodes) were collected on two separate occasions. During the summer of 2009, single samples were taken from 200 sites in the AOSR; a subset of 20 of these was selected for determination of PAHs. During the summer of 2011, triplicate samples (from separate trees within a site) were collected from 20 sites representing similar locations to the 2008 sites. Lichens were milled in a cryogenic impactor, then were extracted with cyclohexane. Extracts were purified on silica gel using automated solid phase extraction and analyzed by gas chromatography with mass selective detection. Method detection limits for individual PAHs were 2-4 ng/g. Total PAHs in the samples from both collection events ranged from 50 ng/g to 350 ng/g, and declined with increasing distance from the mining and refinery operations. The relative contribution of low ring number PAHs to total PAHs increased with increasing distance. Total PAHs correlated strongly (R2 > 0.80, p < 0.05) with crustal elements, suggesting similar transport mechanisms. Analytical data for PAHs on PM 2.5 filters, including relationships between concentrations, PAH profiles, and distance from the mines, will be presented. The lichen data are consistent with PAH transport close to the mines being more influenced by particulate matter transport mechanisms, whereas PAHs in samples collected from remote areas reflect more of the vapor phase transport mechanisms.
Dunn, Kevin H; Tsai, Candace Su-Jung; Woskie, Susan R; Bennett, James S; Garcia, Alberto; Ellenbecker, Michael J
2014-01-01
The most commonly reported control used to minimize workplace exposures to nanomaterials is the chemical fume hood. Studies have shown, however, that significant releases of nanoparticles can occur when materials are handled inside fume hoods. This study evaluated the performance of a new commercially available nano fume hood using three different test protocols. Tracer gas, tracer nanoparticle, and nanopowder handling protocols were used to evaluate the hood. A static test procedure using tracer gas (sulfur hexafluoride) and nanoparticles as well as an active test using an operator handling nanoalumina were conducted. A commercially available particle generator was used to produce sodium chloride tracer nanoparticles. Containment effectiveness was evaluated by sampling both in the breathing zone (BZ) of a mannequin and operator as well as across the hood opening. These containment tests were conducted across a range of hood face velocities (60, 80, and 100 ft/min) and with the room ventilation system turned off and on. For the tracer gas and tracer nanoparticle tests, leakage was much more prominent on the left side of the hood (closest to the room supply air diffuser) although some leakage was noted on the right side and in the BZ sample locations. During the tracer gas and tracer nanoparticle tests, leakage was primarily noted when the room air conditioner was on for both the low and medium hood exhaust airflows. When the room air conditioner was turned off, the static tracer gas tests showed good containment across most test conditions. The tracer gas and nanoparticle test results were well correlated showing hood leakage under the same conditions and at the same sample locations. The impact of a room air conditioner was demonstrated with containment being adversely impacted during the use of room air ventilation. The tracer nanoparticle approach is a simple method requiring minimal setup and instrumentation. However, the method requires the reduction in background concentrations to allow for increased sensitivity.
Contribution of Vegetation to the Microbial Composition of Nearby Outdoor Air
Adams, Rachel I.
2016-01-01
ABSTRACT Given that epiphytic microbes are often found in large population sizes on plants, we tested the hypothesis that plants are quantitatively important local sources of airborne microorganisms. The abundance of microbial communities, determined by quantifying bacterial 16S RNA genes and the fungal internal transcribed spacer (ITS) region, in air collected directly above vegetation was 2- to 10-fold higher than that in air collected simultaneously in an adjacent nonvegetated area 50 m upwind. Nonmetric multidimensional scaling revealed that the composition of airborne bacteria in upwind air samples grouped separately from that of downwind air samples, while communities on plants and downwind air could not be distinguished. In contrast, fungal taxa in air samples were more similar to each other than to the fungal epiphytes. A source-tracking algorithm revealed that up to 50% of airborne bacteria in downwind air samples were presumably of local plant origin. The difference in the proportional abundances of a given operational taxonomic unit (OTU) between downwind and upwind air when regressed against the proportional representation of this OTU on the plant yielded a positive slope for both bacteria and fungi, indicating that those taxa that were most abundant on plants proportionally contributed more to downwind air. Epiphytic fungi were less of a determinant of the microbiological distinctiveness of downwind air and upwind air than epiphytic bacteria. Emigration of epiphytic bacteria and, to a lesser extent, fungi, from plants can thus influence the microbial composition of nearby air, a finding that has important implications for surrounding ecosystems, including the built environment into which outdoor air can penetrate. IMPORTANCE This paper addresses the poorly understood role of bacterial and fungal epiphytes, the inhabitants of the aboveground plant parts, in the composition of airborne microbes in outdoor air. It is widely held that epiphytes contribute to atmospheric microbial assemblages, but much of what we know is limited to qualitative assessments. Elucidating the sources of microbes in outdoor air can inform basic biological processes seen in airborne communities (e.g., dispersal and biogeographical patterns). Furthermore, given the considerable contribution of outdoor air to microbial communities found within indoor environments, the understanding of plants as sources of airborne microbes in outdoor air might contribute to our understanding of indoor air quality. With an experimental design developed to minimize the likelihood of other-than-local plant sources contributing to the composition of airborne microbes, we provide direct evidence that plants are quantitatively important local sources of airborne microorganisms, with implications for the surrounding ecosystems. PMID:27107117
Contribution of Vegetation to the Microbial Composition of Nearby Outdoor Air.
Lymperopoulou, Despoina S; Adams, Rachel I; Lindow, Steven E
2016-07-01
Given that epiphytic microbes are often found in large population sizes on plants, we tested the hypothesis that plants are quantitatively important local sources of airborne microorganisms. The abundance of microbial communities, determined by quantifying bacterial 16S RNA genes and the fungal internal transcribed spacer (ITS) region, in air collected directly above vegetation was 2- to 10-fold higher than that in air collected simultaneously in an adjacent nonvegetated area 50 m upwind. Nonmetric multidimensional scaling revealed that the composition of airborne bacteria in upwind air samples grouped separately from that of downwind air samples, while communities on plants and downwind air could not be distinguished. In contrast, fungal taxa in air samples were more similar to each other than to the fungal epiphytes. A source-tracking algorithm revealed that up to 50% of airborne bacteria in downwind air samples were presumably of local plant origin. The difference in the proportional abundances of a given operational taxonomic unit (OTU) between downwind and upwind air when regressed against the proportional representation of this OTU on the plant yielded a positive slope for both bacteria and fungi, indicating that those taxa that were most abundant on plants proportionally contributed more to downwind air. Epiphytic fungi were less of a determinant of the microbiological distinctiveness of downwind air and upwind air than epiphytic bacteria. Emigration of epiphytic bacteria and, to a lesser extent, fungi, from plants can thus influence the microbial composition of nearby air, a finding that has important implications for surrounding ecosystems, including the built environment into which outdoor air can penetrate. This paper addresses the poorly understood role of bacterial and fungal epiphytes, the inhabitants of the aboveground plant parts, in the composition of airborne microbes in outdoor air. It is widely held that epiphytes contribute to atmospheric microbial assemblages, but much of what we know is limited to qualitative assessments. Elucidating the sources of microbes in outdoor air can inform basic biological processes seen in airborne communities (e.g., dispersal and biogeographical patterns). Furthermore, given the considerable contribution of outdoor air to microbial communities found within indoor environments, the understanding of plants as sources of airborne microbes in outdoor air might contribute to our understanding of indoor air quality. With an experimental design developed to minimize the likelihood of other-than-local plant sources contributing to the composition of airborne microbes, we provide direct evidence that plants are quantitatively important local sources of airborne microorganisms, with implications for the surrounding ecosystems. Copyright © 2016 Lymperopoulou et al.
ANITA Air Monitoring on the International Space Station: Results Compared to Other Measurements
NASA Technical Reports Server (NTRS)
Honne, A.; Schumann-Olsen, H.; Kaspersen, K.; Limero, T.; Macatangay, A.; Mosebach, H.; Kampf, D.; Mudgett, P. D.; James, J. T.; Tan, G.;
2009-01-01
ANITA (Analysing Interferometer for Ambient Air) is a flight experiment precursor for a permanent continuous air quality monitoring system on the ISS (International Space Station). For the safety of the crew, ANITA can detect and quantify quasi-online and simultaneously 33 gas compounds in the air with ppm or sub-ppm detection limits. The autonomous measurement system is based on FTIR (Fourier Transform Infra-Red spectroscopy). The system represents a versatile air quality monitor, allowing for the first time the detection and monitoring of trace gas dynamics in a spacecraft atmosphere. ANITA operated on the ISS from September 2007 to August 2008. This paper summarizes the results of ANITA s air analyses with emphasis on comparisons to other measurements. The main basis of comparison is NASA s set of grab samples taken onboard the ISS and analysed on ground applying various GC-based (Gas Chromatography) systems.
Ahearn, D G; Crow, S A; Simmons, R B; Price, D L; Noble, J A; Mishra, S K; Pierson, D L
1996-05-01
Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.
NASA Technical Reports Server (NTRS)
Ahearn, D. G.; Crow, S. A.; Simmons, R. B.; Price, D. L.; Noble, J. A.; Mishra, S. K.; Pierson, D. L.
1996-01-01
Complaints characteristic of those for sick building syndrome prompted mycological investigations of a modern multi-story office building on the Gulf coast in the Southeastern United States (Houston-Galveston area). The air handling units and fiberglass duct liner of the heating, ventilating and air conditioning system of the building, without a history of catastrophic or chronic water damage, demonstrated extensive colonization with Penicillium spp and Cladosporium herbarum. Although dense fungal growth was observed on surfaces within the heating-cooling system, most air samples yielded fewer than 200 CFU m-3. Several volatile compounds found in the building air were released also from colonized fiberglass. Removal of colonized insulation from the floor receiving the majority of complaints of mouldy air and continuous operation of the units supplying this floor resulted in a reduction in the number of complaints.
Asbestos Analysis: What School Officials Should Know.
ERIC Educational Resources Information Center
Harris, Bonnie Lee
1984-01-01
Transmission electron microscopy and scanning electron microscopy are used to detect asbestos by analyzing filters from air tests. The modes of operation and types of samples examined by each are explained. Circumstances that a school board should consider when deciding whether to use these methods are discussed. (MLF)
NASA Astrophysics Data System (ADS)
Blake, D. R.; Yang, M.; Meinardi, S.; Krauter, C.; Rowland, F. S.
2009-05-01
The San Joaquin Valley Air Pollution Control District of California issued a report identifying dairies as a main source of Volatile Organic Compounds (VOCs). A dairy study funded by the California Air Resources Board commenced shortly after the report was issued. Our University of California Irvine group teamed with California State University Fresno to determine the major sources of VOCs from various dairy operations and from a variety of dairy types. This study identified ethanol and methanol as two gases produced in major quantities throughout the dairies in the San Joaquin valley as by-products of yeast fermentation of silage. Three different types of sampling protocols were employed in order to determine the degree of enhancement of the target oxygenates in the valley air shed. Their sources, emission profiles, and emission rates were determined from whole air samples collected at various locations at the six dairies studied. An assessment of the impact of dairy emissions in the valley was achieved by using data obtained on low altitude NASA DC-8 flights through the valley, and from ground level samples collected though out the valley in a grid like design. Our data suggest that a significant amount of O3 production in the valley may come from methanol, ethanol, and acetaldehyde (a photochemical by-product ethanol oxidation). Our findings indicate that improvement to valley air quality may be obtained by focusing on instituting new silage containment practices and regulations.
The microbiological quality of air improves when using air conditioning systems in cars.
Vonberg, Ralf-Peter; Gastmeier, Petra; Kenneweg, Björn; Holdack-Janssen, Hinrich; Sohr, Dorit; Chaberny, Iris F
2010-06-01
Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle--and by this its impact on the risk of an allergic reaction--is yet unknown. Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system. Operation modes using fresh air from outside the car as well as circulating air from inside the car were examined. The total number of microorganisms and the number of mold spores were measured by impaction in a high flow air sampler. Particles of 0.5 to 5.0 microm diameter were counted by a laser particle counter device. Overall 32 occasions of sampling were performed. The concentration of microorganisms outside the cars was always higher than it was inside the cars. Few minutes after starting the air conditioning system the total number of microorganisms was reduced by 81.7%, the number of mold spores was reduced by 83.3%, and the number of particles was reduced by 87.8%. There were no significant differences neither between the types of cars nor between the types of operation mode of the air conditioning system (fresh air vs. circulating air). All parameters that were looked for in this study improved during utilization of the car's air conditioning system. We believe that the risk of an allergic reaction will be reduced during use also. Nevertheless, we recommend regular maintenance of the system and replacement of older filters after defined changing intervals.
The microbiological quality of air improves when using air conditioning systems in cars
2010-01-01
Background Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle - and by this its impact on the risk of an allergic reaction - is yet unknown. Methods Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system. Operation modes using fresh air from outside the car as well as circulating air from inside the car were examined. The total number of microorganisms and the number of mold spores were measured by impaction in a high flow air sampler. Particles of 0.5 to 5.0 μm diameter were counted by a laser particle counter device. Results Overall 32 occasions of sampling were performed. The concentration of microorganisms outside the cars was always higher than it was inside the cars. Few minutes after starting the air conditioning system the total number of microorganisms was reduced by 81.7%, the number of mold spores was reduced by 83.3%, and the number of particles was reduced by 87.8%. There were no significant differences neither between the types of cars nor between the types of operation mode of the air conditioning system (fresh air vs. circulating air). All parameters that were looked for in this study improved during utilization of the car's air conditioning system. Conclusions We believe that the risk of an allergic reaction will be reduced during use also. Nevertheless, we recommend regular maintenance of the system and replacement of older filters after defined changing intervals. PMID:20515449
Design of a small personal air monitor and its application in aircraft.
van Netten, Chris
2009-01-15
A small air sampling system using standard air filter sampling technology has been used to monitor the air in aircraft. The device is a small ABS constructed cylinder 5 cm in diameter and 9 cm tall and can be operated by non technical individuals at an instant notice. It is completely self contained with a 4 AAA cell power supply, DC motor, a centrifugal fan, and accommodates standard 37 mm filters and backup pads. The monitor is totally enclosed and pre assembled in the laboratory. A 45 degrees twist of the cap switches on the motor and simultaneously opens up the intake ports and exhaust ports allowing air to pass through the filter. A reverse 45 degrees twist of the cap switches off the motor and closes all intake and exhaust ports, completely enclosing the filter. The whole monitor is returned to the laboratory by standard mail for analysis and reassembly for future use. The sampler has been tested for electromagnetic interference and has been approved for use in aircraft during all phases of flight. A set of samples taken by a BAe-146-300 crew member during two flights in the same aircraft and analyzed by GC-MS, indicated exposure to tricresyl phosphate (TCP) levels ranging from 31 to 83 nanograms/m(3) (detection limit <4.5 nanograms/m(3)). The latter elevated level was associated with the use of the auxiliary power unit (APU) in the aircraft. It was concluded that the air sampler was capable of monitoring air concentrations of TCP isomers in aircraft above 4.5 nanogram/m(3).
NASA Astrophysics Data System (ADS)
Ghosh, B.
2017-12-01
Volatile organic compounds (VOCs) are emitted into the atmosphere from a variety of sources including oil and gas (O&G) operations, vehicle exhausts, industrial processes, and biogenic sources. Understanding of emission sources and their air quality impact is crucial for effective environmental policymaking and its implementation. Three consecutive wintertime campaigns to study ambient air were conducted in Northeastern Oklahoma during February-March of 2015, 2016, and 2017. The goals of these campaigns were to study ambient VOCs in the region, estimate their air quality impact, and understand how the impact changes over a span of three years. This presentation highlights results from the 2017 campaign. In-situ measurements of methane, ethane, and CO were conducted by an Aerodyne Dual QCL Analyzer while ozone and NOx were measured using Teledyne monitors. In addition, 392 whole air samples were collected and non-methane hydrocarbons (NMHCs) in the samples were analyzed using GC-MS (Agilent). High levels of methane (> 8 ppm) were observed during the study. Correlation with ethane indicated that methane primarily originated from O&G operations with little biogenic contributions. Among NMHCs, C2-C5 alkanes were the most dominant with mean mixing ratios ranging from 0.9 to 6.8 ppb. Chemical tracers (propane, ethyne, CO) and isomeric ratios (iC5/nC5, Figure 1) identified oil and gas activity as the primary source of NMHCs. Photochemical age was calculated to estimate emission source composition. Ozone showed strong diurnal variation characteristic of photochemical production with a maximum mixing ratio of 58 ppb. The results from the 2017 study will be compared with results from studies in 20151 and 20162 and their significance on local air quality will be discussed. References Ghosh, B.; Volatile Organic Compound Emissions from Oil and Gas Production Sources: A Pilot Study in Northeastern Oklahoma; Poster presentation at AGU Fall Meeting; 2015; A11M-0249; (Link) Ghosh, B.; Hydrocarbon Emission from Oil and Gas Production Activity in Northeastern Oklahoma - Wintertime Measurements in 2015 and 2016; Oral Presentation at AGU Fall Meeting; 2016; A14A-08; (Link)
Bacteriological evaluation of a down-draught necropsy table ventilation system.
al-Wali, W; Kibbler, C C; McLaughlin, J E
1993-08-01
To evaluate the microbiological efficacy of a down-draught necropsy table ventilation system (which surrounds the cadaver with a "curtain" of air under continuous extraction) during post mortem procedures. Air sampling was carried out both in the presence and absence of staff and cadaver and during a full post mortem procedure, with functioning and non-functioning table air extraction. The penetration of the air "curtain" was also examined during the use of an oscillating bone saw by means of a tracer organism, Bacillus subtilis var niger, painted on to the skull. There was little difference between bacterial counts obtained in the presence of staff only, staff plus cadaver, or during a post mortem examination. With all counts obtained, however, there was a two to three-fold reduction when the ventilation was in operation compared with when the extract duct was occluded. Using the tracer organism, a two to three log reduction in counts was shown when the "curtain" was in operation during the use of the oscillating bone saw. These results suggest that the system provides potential protection for post mortem room staff against airborne infections.
14 CFR 25.1527 - Ambient air temperature and operating altitude.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Ambient air temperature and operating... Information Operating Limitations § 25.1527 Ambient air temperature and operating altitude. The extremes of the ambient air temperature and operating altitude for which operation is allowed, as limited by...
14 CFR 25.1527 - Ambient air temperature and operating altitude.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Ambient air temperature and operating... Information Operating Limitations § 25.1527 Ambient air temperature and operating altitude. The extremes of the ambient air temperature and operating altitude for which operation is allowed, as limited by...
14 CFR 25.1527 - Ambient air temperature and operating altitude.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Ambient air temperature and operating... Information Operating Limitations § 25.1527 Ambient air temperature and operating altitude. The extremes of the ambient air temperature and operating altitude for which operation is allowed, as limited by...
14 CFR 25.1527 - Ambient air temperature and operating altitude.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Ambient air temperature and operating... Information Operating Limitations § 25.1527 Ambient air temperature and operating altitude. The extremes of the ambient air temperature and operating altitude for which operation is allowed, as limited by...
Air Force Special Operations Command > Home > POTFF
Air Force Special Operations Command Air Force Special Operations Command Join the Air Force Home Sheets AFSOC Senior Leaders AFSOC Heritage Units 1st Special Operations Wing 24th Special Operations Wing 27th Special Operations Wing 352nd Special Operations Wing 353rd Special Operations Group 492nd Special
Angosto, J M; Fernández-López, J A; Godínez, C
2015-01-01
This work aims at the comparison of the electrical and chemical performance of microbial fuel cells (MFCs) fed with several types of brewery and manure industrial wastewaters. Experiments were conducted in a single-cell MFC with the cathode exposed to air operated in batch and fed-batch modes. In fed-batch mode, after 4 days of operation, a standard MFC was refilled with crude wastewater to regenerate the biofilm and recreate initial feeding conditions. Brewery wastewater (CV1) mixed with pig-farm liquid manure (PU sample) gave the highest voltage (199.8 mV) and power density (340 mW/m3) outputs than non-mixed brewery waste water. Also, coulombic efficiency is much larger in the mixture (11%) than in the others (2-3%). However, in terms of chemical oxygen demand removal, the performance showed to be poorer (53%) for the mixed sample than in the pure brewery sample (93%). Fed-batch operation showed to be a good alternate for quasi-continuous operation, with equivalent electrical and chemical yields as compared with normal batchwise operation.
Microbial Groundwater Sampling Protocol for Fecal-Rich Environments
Harter, Thomas; Watanabe, Naoko; Li, Xunde; Atwill, Edward R; Samuels, William
2014-01-01
Inherently, confined animal farming operations (CAFOs) and other intense fecal-rich environments are potential sources of groundwater contamination by enteric pathogens. The ubiquity of microbial matter poses unique technical challenges in addition to economic constraints when sampling wells in such environments. In this paper, we evaluate a groundwater sampling protocol that relies on extended purging with a portable submersible stainless steel pump and Teflon® tubing as an alternative to equipment sterilization. The protocol allows for collecting a large number of samples quickly, relatively inexpensively, and under field conditions with limited access to capacity for sterilizing equipment. The protocol is tested on CAFO monitoring wells and considers three cross-contamination sources: equipment, wellbore, and ambient air. For the assessment, we use Enterococcus, a ubiquitous fecal indicator bacterium (FIB), in laboratory and field tests with spiked and blank samples, and in an extensive, multi-year field sampling campaign on 17 wells within 2 CAFOs. The assessment shows that extended purging can successfully control for equipment cross-contamination, but also controls for significant contamination of the well-head, within the well casing and within the immediate aquifer vicinity of the well-screen. Importantly, our tests further indicate that Enterococcus is frequently entrained in water samples when exposed to ambient air at a CAFO during sample collection. Wellbore and air contamination pose separate challenges in the design of groundwater monitoring strategies on CAFOs that are not addressed by equipment sterilization, but require adequate QA/QC procedures and can be addressed by the proposed sampling strategy. PMID:24903186
Low and medium heating value coal gas catalytic combustor characterization
NASA Technical Reports Server (NTRS)
Schwab, J. A.
1982-01-01
Catalytic combustion with both low and medium heating value coal gases obtained from an operating gasifier was demonstrated. A practical operating range for efficient operation was determined, and also to identify potential problem areas were identified for consideration during stationary gas turbine engine design. The test rig consists of fuel injectors, a fuel-air premixing section, a catalytic reactor with thermocouple instrumentation and a single point, water cooled sample probe. The test rig included inlet and outlet transition pieces and was designed for installation into an existing test loop.
US EPA's National Dioxin Air Monitoring Network: Analytical ...
The U.S. EPA has established a National Dioxin Air Monitoring Network (NDAMN) to determine the temporal and geographical variability of atmospheric chlorinated dibenzo-p-dioxins (CDDs), furans (CDFs), and coplanar polychlorinated biphenyls (PCBs) at rural and non-impacted locations throughout the United States. Currently operating at 32 sampling stations, NDAMN has three primary purposes: (1) to determine the atmospheric levels and occurrences of dioxin-like compounds in rural and agricultural areas where livestock, poultry, and animal feed crops are grown; (2) to provide measurements of atmospheric levels in different geographic regions of the U.S.; and (3) to provide information regarding the long-range transport of dioxin-like compounds in air over the U.S. Designed in 1997, NDAMN has been implemented in phases, with the first phase consisting of 9 monitoring stations and is achieving congener-specific detection lmits of 0.1 fg/m3 for 2,3,7,8-TCDD and 10 fg/m3 for OCDD. With respect to coplanar PCBs, the detection limits are generally higher due to the presence of background levels in the air during the preparation and processing of the samples. Achieving these extremely low levels of detection present a host of analytical issues. Among these issues are the methods used to establish ultra-trace detection limits, measures to ensure against and monitor for breakthrough of native analytes when sampling large volumes of air, and procedures for handling and e
DOE Office of Scientific and Technical Information (OSTI.GOV)
MULKEY, C.H.
1999-07-06
This document describes the results of the data quality objective (DQO) process undertaken to define data needs for state and federal requirements associated with toxic, hazardous, and/or radiological air emissions under the jurisdiction of the River Protection Project (RPP). Hereafter, this document is referred to as the Air DQO. The primary drivers for characterization under this DQO are the regulatory requirements pursuant to Washington State regulations, that may require sampling and analysis. The federal regulations concerning air emissions are incorporated into the Washington State regulations. Data needs exist for nonradioactive and radioactive waste constituents and characteristics as identified through themore » DQO process described in this document. The purpose is to identify current data needs for complying with regulatory drivers for the measurement of air emissions from RPP facilities in support of air permitting. These drivers include best management practices; similar analyses may have more than one regulatory driver. This document should not be used for determining overall compliance with regulations because the regulations are in constant change, and this document may not reflect the latest regulatory requirements. Regulatory requirements are also expected to change as various permits are issued. Data needs require samples for both radionuclides and nonradionuclide analytes of air emissions from tanks and stored waste containers. The collection of data is to support environmental permitting and compliance, not for health and safety issues. This document does not address health or safety regulations or requirements (those of the Occupational Safety and Health Administration or the National Institute of Occupational Safety and Health) or continuous emission monitoring systems. This DQO is applicable to all equipment, facilities, and operations under the jurisdiction of RPP that emit or have the potential to emit regulated air pollutants.« less
Air quality measurements-From rubber bands to tapping the rainbow.
Hidy, George M; Mueller, Peter K; Altshuler, Samuel L; Chow, Judith C; Watson, John G
2017-06-01
It is axiomatic that good measurements are integral to good public policy for environmental protection. The generalized term for "measurements" includes sampling and quantitation, data integrity, documentation, network design, sponsorship, operations, archiving, and accessing for applications. Each of these components has evolved and advanced over the last 200 years as knowledge of atmospheric chemistry and physics has matured. Air quality was first detected by what people could see and smell in contaminated air. Gaseous pollutants were found to react with certain materials or chemicals, changing the color of dissolved reagents such that their light absorption at selected wavelengths could be related to both the pollutant chemistry and its concentration. Airborne particles have challenged the development of a variety of sensory devices and laboratory assays for characterization of their enormous range of physical and chemical properties. Advanced electronics made possible the sampling, concentration, and detection of gases and particles, both in situ and in laboratory analysis of collected samples. Accurate and precise measurements by these methods have made possible advanced air quality management practices that led to decreasing concentrations over time. New technologies are leading to smaller and cheaper measurement systems that can further expand and enhance current air pollution monitoring networks. Ambient air quality measurement systems have a large influence on air quality management by determining compliance, tracking trends, elucidating pollutant transport and transformation, and relating concentrations to adverse effects. These systems consist of more than just instrumentation, and involve extensive support efforts for siting, maintenance, calibration, auditing, data validation, data management and access, and data interpretation. These requirements have largely been attained for criteria pollutants regulated by National Ambient Air Quality Standards, but they are rarely attained for nonroutine measurements and research studies.
Small-size mass spectrometer for determining gases and volatile compounds in air during breathing
NASA Astrophysics Data System (ADS)
Kogan, V. T.; Kozlenok, A. V.; Chichagov, Yu. V.; Antonov, A. S.; Lebedev, D. S.; Bogdanov, A. A.; Moroshkin, V. S.; Berezina, A. V.; Viktorova-Leclerc, O. S.; Vlasov, S. A.; Tubol'tsev, Yu. V.
2015-10-01
We describe an automated mass spectrometer for diagnostics of deceases from the composition of exhaled air. It includes a capillary system, which performs a rapid direct feeding of the sample to the instrument without changing substantially its composition and serves for studying the dynamics of variation of the ratio between various components of exhaled air. The membrane system for introducing the sample is intended for determining low concentrations of volatile organic compounds which are biomarkers of pathologies. It is characterized by selective transmittance and ensures the detection limits of target compounds at the parts per million-parts per billion (ppm-ppb) level. A static mass analyzer operating on permanent magnets possesses advantages important for mobile devices as compared to its dynamic analogs: it is more reliable in operation, has a larger dynamic range, and can be used for determining the concentration of components in the mixture one-by-one or simultaneously. The curvilinear output boundary of the magnetic lens of the mass analyzer makes it possible to reduce its weight and size by 2.5 times without deteriorating the mass resolution. We report on the results of testing of the instrument and consider the possibility of its application for early detection of deceases of respiratory and blood circulation system, gastrointestinal tract, and endocrine system.
Mendez, Gregory O.; Foreman, William T.; Sidhu, Jagdeep S.; Majewski, Michael S.
2007-01-01
In 1998, the U.S. Geological Survey, in cooperation with the Sweetwater Authority, began a study to assess the overall health of the Sweetwater watershed with respect to chemical contamination. The study included regular sampling of air and water at Sweetwater Reservoir for chemical contaminants, including volatile organic compounds, polycyclic aromatic hydrocarbons, pesticides, and major and trace elements. Background water samples were collected at Loveland Reservoir for volatile organic compounds and pesticides. The purpose of this study was to monitor changes in contaminant composition and concentration in the air and water resulting from the construction and operation of State Route 125 near Sweetwater Reservoir. To accomplish this, the study was divided into two phases. Phase One sampling was designed to establish baseline conditions for target compounds in terms of detection frequency and concentration in air and water. Phase Two sampling is planned to continue at the established monitoring sites during and after construction of State Route 125 to assess the chemical impact this roadway alignment project may have on the water quality in the reservoir. In addition to the ongoing data collection, several special studies were initiated to assess the occurrence of specific chemicals of concern, such as low-use pesticides, trace metals, and wastewater compounds. This report describes the study design, and the sampling and analytical methods, and presents the results for the second and third years of the study (October 1999 to September 2001). Data collected during the first year of sampling (October 1998 to September 1999) were published in 2002.
Quantifying the size-resolved dynamics of indoor bioaerosol transport and control.
Kunkel, S A; Azimi, P; Zhao, H; Stark, B C; Stephens, B
2017-09-01
Understanding the bioaerosol dynamics of droplets and droplet nuclei emitted during respiratory activities is important for understanding how infectious diseases are transmitted and potentially controlled. To this end, we conducted experiments to quantify the size-resolved dynamics of indoor bioaerosol transport and control in an unoccupied apartment unit operating under four different HVAC particle filtration conditions. Two model organisms (Escherichia coli K12 and bacteriophage T4) were aerosolized under alternating low and high flow rates to roughly represent constant breathing and periodic coughing. Size-resolved aerosol sampling and settle plate swabbing were conducted in multiple locations. Samples were analyzed by DNA extraction and quantitative polymerase chain reaction (qPCR). DNA from both organisms was detected during all test conditions in all air samples up to 7 m away from the source, but decreased in magnitude with the distance from the source. A greater fraction of T4 DNA was recovered from the aerosol size fractions smaller than 1 μm than E. coli K12 at all air sampling locations. Higher efficiency HVAC filtration also reduced the amount of DNA recovered in air samples and on settle plates located 3-7 m from the source. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Decreasing Free Radicals Level on High Risk Person After Vitamin C and E Supplement Treatment
NASA Astrophysics Data System (ADS)
Sitorus, M. S.; Anggraini, D. R.; Hidayat
2017-03-01
Has become a global issue that the increase in global warming mainly caused by high air pollution levels which are donated by motor vehicle emissions. As a rapidly developing country, Indonesia becomes vulnerable to health problems related to air pollution. Excessive free radicals that is produced by air pollution can initiate stress oxidative. Already known that, stress oxidative trigger many health problems. Vitamin C and E is a non enzymatic antioxidant that can neutralize free radicals. This study aims to investigate the decreasing free radicals level by administering vitamin C and E. This research using pre and post experimental design study. There are 24 operators gasoline station Pertamina as samples, with an average age of 26 years. The samples were divided into 4 groups. Group 1 (control), group 2, were given vitamin C doses of 500mg / day, group 3 was given vitamin E doses of 250 IU / day and the group 4 was given a combination of vitamins C and E. The treatment was given for 30 days. Free radicals level is obtained from malonaldehyde (MDA) level by spectrophotometer. Before treatment the average of MDA level is 5.540 µm. After the treatment, MDA is significantly decreased become 3.992 µm (T-test, sig<0.05). This result can be used as a sign of side affect of air pollutant in the operator SPBU. As reminding to protect the employee with safety aid and supplement.
NASA Astrophysics Data System (ADS)
Pikelnaya, O.; Polidori, A.; Low, J.
2017-12-01
Hexavalent chromium [Cr(VI)] and other toxic metals are often emitted during metal forging, cutting, grinding and plating operations. In the South Coast Air Basin (SCAB) many of such operations are conducted by relatively small facilities intertwined within residential communities in the cities of Paramount, Compton, Long Beach and Anaheim. In response to the city of Paramount community members' complaints of "metallic" odors, the South Coast Air Quality Management District (SCAQMD) initiated a local air sampling study for toxic metals, which found elevated Cr(VI) and nickel levels in the community downwind of selected metal processing facilities. SCAQMD worked with these facilities to reduce the emissions from their metal grinding operations, which resulted in substantial reduced nickel levels, but did not reduce Cr(VI) levels. In order to fully understand the source(s) of these emissions, SCAQMD has been deploying portable samplers for Cr(VI) monitoring throughout the city of Paramount since October 2016. During this presentation we will discuss the results of more than a year of Cr(VI) analyses of samplers collected throughout the City of Paramount, as well as data from a continuous metal monitor deployed at one of the sites. We will also discuss options and challenges for expanding of Cr(VI) monitoring to other communities in the SCAB that are adjacent to metal forging and grinding operations; and explore emerging new technologies to address such monitoring challenges.
Offenthaler, I; Jakobi, G; Kaiser, A; Kirchner, M; Kräuchi, N; Niedermoser, B; Schramm, K-W; Sedivy, I; Staudinger, M; Thanner, G; Weiss, P; Moche, W
2009-12-01
High- and low-volume active air samplers as well as bulk deposition samplers were developed to sample atmospheric SOCs under the adverse conditions of a mountain environment. Active sampling employed separate filters for different European source regions. Filters were switched depending on daily trajectory forecasts, whose accuracy was evaluated post hoc. The sampling continued on three alpine summits over five periods of four months. The prevailing trajectories varied stronger between sampling periods than between stations. The sampling equipment (active and bulk deposition) proved dependable for operation in a mountain environment, with idle times being mainly due to non-routine manipulations and connectivity.
Gas analysis system for the Eight Foot High Temperature Tunnel
NASA Technical Reports Server (NTRS)
Leighty, Bradley D.; Davis, Patricia P.; Upchurch, Billy T.; Puster, Richard L.
1992-01-01
This paper describes the development of a gas collection and analysis system that is to be installed in the Eight-Foot High Temperature Tunnel (8' HTT) at NASA's Langley Research Center. This system will be used to analyze the test gas medium that results after burning a methane-air mixture to achieve the proper tunnel test parameters. The system consists of a sampling rake, a gas sample storage array, and a gas chromatographic system. Gas samples will be analyzed after each run to assure that proper combustion takes place in the tunnel resulting in a correctly balanced composition of the test gas medium. The proper ratio of gas species is critically necessary in order for the proper operation and testing of scramjet engines in the tunnel. After a variety of methane-air burn conditions have been analyzed, additional oxygen will be introduced into the combusted gas and the enriched test gas medium analyzed. The pre/post enrichment sets of data will be compared to verify that the gas species of the test gas medium is correctly balanced for testing of air-breathing engines.
Wu, Chien-Hou; Lin, Ming-Nan; Feng, Chien-Tai; Yang, Kuang-Ling; Lo, Yu-Shiu; Lo, Jiunn-Guang
2003-05-09
A method for the qualitative and quantitative analysis of volatile organic compounds (VOCs) in the air of class-100 clean rooms at semiconductor fabrication facilities was developed. Air samples from two semiconductor factories were collected each hour on multisorbent tubes (including Carbopack B, Carbopack C, and Carbosieve SIII) with a 24-h automatic active sampling system and analyzed using adsorption/thermal desorption coupled with gas chromatography-mass spectrometry. Experimental parameters, including thermal desorption temperature, desorption time, and cryofocusing temperature, were optimized. The average recoveries and the method detection limits for the target compounds were in the range 94-101% and 0.31-0.89 ppb, respectively, under the conditions of a 1 L sampling volume and 80% relative humidity. VOCs such as acetone, isopropyl alcohol, 2-heptanone, and toluene, which are commonly used in the semiconductor and electronics industries, were detected and accurately quantified with the established method. Temporal variations of the analyte concentrations observed were attributed to the improper use of organic solvents during operation.
14 CFR 298.38 - Financial security arrangements for operating Public Charters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER... security arrangements for operating Public Charters. When an air taxi operator or commuter air carrier performs a Public Charter under part 380 of this chapter, either: (a) The air taxi operator or commuter air...
14 CFR 298.38 - Financial security arrangements for operating Public Charters.
Code of Federal Regulations, 2011 CFR
2011-01-01
... OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER... security arrangements for operating Public Charters. When an air taxi operator or commuter air carrier performs a Public Charter under part 380 of this chapter, either: (a) The air taxi operator or commuter air...
Cundell, A M; Bean, R; Massimore, L; Maier, C
1998-01-01
To determine the relationship between the sampling time of the environmental monitoring, i.e., viable counts, in aseptic filling areas and the microbial count and frequency of alerts for air, surface and personnel microbial monitoring, statistical analyses were conducted on 1) the frequency of alerts versus the time of day for routine environmental sampling conducted in calendar year 1994, and 2) environmental monitoring data collected at 30-minute intervals during routine aseptic filling operations over two separate days in four different clean rooms with multiple shifts and equipment set-ups at a parenteral manufacturing facility. Statistical analyses showed, except for one floor location that had significantly higher number of counts but no alert or action level samplings in the first two hours of operation, there was no relationship between the number of counts and the time of sampling. Further studies over a 30-day period at the floor location showed no relationship between time of sampling and microbial counts. The conclusion reached in the study was that there is no worst case time for environmental monitoring at that facility and that sampling any time during the aseptic filling operation will give a satisfactory measure of the microbial cleanliness in the clean room during the set-up and aseptic filling operation.
14 CFR 298.37 - Prohibition of services not covered by insurance.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS... insurance. An air taxi operator or commuter air carrier shall not operate in air transportation or provide...
14 CFR 298.37 - Prohibition of services not covered by insurance.
Code of Federal Regulations, 2011 CFR
2011-01-01
... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS... insurance. An air taxi operator or commuter air carrier shall not operate in air transportation or provide...
Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos
2008-01-01
Background Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Methods Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. Results The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH ≥7.8 and total plate count ≥400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of ≥0.2 mg/L inhibited colonization of Legionella spp. Conclusion WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members. PMID:19025638
Goutziana, Georgia; Mouchtouri, Varvara A; Karanika, Maria; Kavagias, Antonios; Stathakis, Nikolaos E; Gourgoulianis, Kostantinos; Kremastinou, Jenny; Hadjichristodoulou, Christos
2008-11-24
Legionnaires' disease continues to be a public health concern in passenger ships. This study was scheduled in order to investigate Legionella spp. colonization of water distribution systems (WDS), recreational pools, and air-conditioning systems on board ferries and cruise ships in an attempt to identify risk factors for Legionella spp. colonization associated with ship water systems and water characteristics. Water systems of 21 ferries and 10 cruise ships including WDS, air conditioning systems and pools were investigated for the presence of Legionella spp. The 133 samples collected from the 10 cruise ships WDS, air conditioning systems and pools were negative for Legionella spp. Of the 21 ferries WDS examined, 14 (66.7%) were legionellae-positive. A total of 276 samples were collected from WDS and air conditioning systems. Legionella spp. was isolated from 37.8% of the hot water samples and 17.5% of the cold water samples. Of the total 96 positive isolates, 87 (90.6%) were L. pneumophila. Legionella spp. colonization was positively associated with ship age. The temperature of the hot water samples was negatively associated with colonization of L. pneumophila serogroup (sg) 1 and that of L. pneumophila sg 2 to 14. Increases in pH >/=7.8 and total plate count > or =400 CFU/L, correlated positively with the counts of L. pneumophila sg 2 to 14 and Legionella spp. respectively. Free chlorine of > or =0.2 mg/L inhibited colonization of Legionella spp. WDS of ferries can be heavily colonized by Legionella spp. and may present a risk of Legionnaires' disease for passengers and crew members. Guidelines and advising of Legionnaires' disease prevention regarding ferries are needed, in particular for operators and crew members.
A study of ethylene glycol exposure and kidney function of aircraft de-icing workers.
Gérin, M; Patrice, S; Bégin, D; Goldberg, M S; Vyskocil, A; Adib, G; Drolet, D; Viau, C
1997-01-01
Ethylene glycol levels were measured in 154 breathing zone air samples and in 117 urine samples of 33 aviation workers exposed to de-icing fluid (basket operators, de-icing truck drivers, leads and coordinators) studied during 42 worker-days over a winter period of 2 months at a Montreal airport. Ethylene glycol as vapour did not exceed 22 mg/m3 (mean duration of samples 50 min). Mist was quantified at higher levels in 3 samples concerning 1 coordinator and 2 basket operators (76-190 mg/m3, 45-118 min). In 16 cases workers' post-shift or next-morning urine contained quantities of ethylene glycol exceeding 5 mmol/mol creatinine (up to 129 mmol/mol creatinine), with most of these instances occurring in basket operators and coordinators, some of whom did not wear paper masks and/or were accidentally sprayed with de-icing fluid. Diethylene glycol was also found in a few air and urinary samples at levels around one tenth those of ethylene glycol. Urinary concentrations of albumin, beta-N-acetyl-glucosaminidase, beta-2-microglobulin and retinol-binding protein were measured and compared over various periods, according to subgroups based on exposure level and according to the frequency of extreme values. These analyses did not demonstrate acute or chronic kidney damage that could be attributed to working in the presence of ethylene glycol. In conclusion, this study does not suggest important health effects of exposure to de-icing fluid in this group of workers. Potential for overexposure exists, however, in certain work situations, and recommendations on preventive measures are given. In addition, these results suggest that other routes of absorption than inhalation, such as the percutaneous route, may be important and that urinary ethylene glycol may be a useful indicator of exposure to ethylene glycol.
In 1993, the University of Michigan Air Quality Laboratory (UMAQL) designed a new wet-only precipitation collection system that was utilized in the Lake Michigan Loading Study. The collection system was designed to collect discrete mercury and trace element samples on an event b...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2008
DOT National Transportation Integrated Search
2008-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2008
DOT National Transportation Integrated Search
2008-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2014
DOT National Transportation Integrated Search
2014-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2011
DOT National Transportation Integrated Search
2011-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : first quarter : [2010
DOT National Transportation Integrated Search
2010-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2013
DOT National Transportation Integrated Search
2013-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : fourth quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : second quarter : [2009
DOT National Transportation Integrated Search
2009-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Data Bank 1B - Ticket Dollar Value Origin and Destination - Public Version : third quarter : [2012
DOT National Transportation Integrated Search
2012-01-01
This CD presents the same data as Data Bank 1B and also includes dual codes for the operating and ticketed carrier and incorporates data as reported each quarter by participating air carriers from the continuous 10% sample of airline tickets. It incl...
Code of Federal Regulations, 2011 CFR
2011-01-01
... REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS General § 298.2 Definitions. As used in this part: Air taxi operator means an air carrier as established by § 298.3(a). Air transportation..., 39 U.S.C. 5402, authorizes the carriage of mail by air taxi operators and commuter air carriers in...
NASA Astrophysics Data System (ADS)
Chalbot, Marie-Cecile; Vei, Ino-Christina; Lianou, Maria; Kotronarou, Anastasia; Karakatsani, Anna; Katsouyanni, Klea; Hoek, Gerard; Kavouras, Ilias G.
2012-12-01
Fine particulate matter samples were collected in an urban ambient fixed site and, outside and inside residencies in Athens greater area, Greece. n-Alkanes, iso/anteiso-alkanes and polycyclic aromatic hydrocarbons (PAHs) were identified by gas chromatography and mass spectrometry. The values of concentration diagnostic ratios indicated a mixture of vehicular emissions, fuel evaporation, oil residues and environmental tobacco smoke (ETS) in outdoor and indoor samples. Particulate iso/anteiso-alkanes, specific tracers of ETS, were detected in both non-smoking and smoking households. The indoor-to-outdoor ratios of particulate iso/anteiso-alkanes and unresolved complex mixture (a tracer of outdoor air pollution) in non-smoking households were comparable to the measured air exchange rate. This suggested that penetration of outdoor air was solely responsible for the detection of tobacco smoke particulate tracers in indoor non-smoking environments. Overall, residential outdoor concentrations accounted for a large fraction (from 25 up to 79%) of indoor aliphatic and polyaromatic hydrocarbons. Open windows/doors and the operation of an air condition unit yielded also in higher indoor concentrations than those measured outdoors.
Marinozzi, Franco; Bini, Fabiano; Marinozzi, Andrea; Zuppante, Francesca; De Paolis, Annalisa; Pecci, Raffaella; Bedini, Rossella
2013-01-01
Micro-CT analysis is a powerful technique for a non-invasive evaluation of the morphometric parameters of trabecular bone samples. This elaboration requires a previous binarization of the images. A problem which arises from the binarization process is the partial volume artifact. Voxels at the external surface of the sample can contain both bone and air so thresholding operates an incorrect estimation of volume occupied by the two materials. The aim of this study is the extraction of bone volumetric information directly from the image histograms, by fitting them with a suitable set of functions. Nineteen trabecular bone samples were extracted from femoral heads of eight patients subject to a hip arthroplasty surgery. Trabecular bone samples were acquired using micro-CT Scanner. Hystograms of the acquired images were computed and fitted by Gaussian-like functions accounting for: a) gray levels produced by the bone x-ray absorption, b) the portions of the image occupied by air and c) voxels that contain a mixture of bone and air. This latter contribution can be considered such as an estimation of the partial volume effect. The comparison of the proposed technique to the bone volumes measured by a reference instrument such as by a helium pycnometer show the method as a good way for an accurate bone volume calculation of trabecular bone samples.
Operation TEAPOT. Report of the Test Manager Joint Test Organization
1981-11-01
Analysis of air, water, and milk samples were made at the laboratory at Mercury. z. 6.4 MONITORING PROCEDURES A mobile surface monitoring group consisting o...additional weather observations proved very use- ful in weather analysis and forecasting as well as for monitoring winds aloft prior to shot time. The...data were also valuable in post analysis for accurate plotting of fallout and determining cloud trajectories. The loca- tion and type of operations of
Recent Weather Technologies Delivered to America's Space Program by the Applied Meteorology Unit
NASA Technical Reports Server (NTRS)
Bauman, WIlliam, H., III; Crawford, Winifred
2009-01-01
The Applied Meteorology Unit (AMU) is a unique joint venture of NASA, the Air Force and the National Weather Service (NWS) and has been supporting the Space Program for nearly two decades. The AMU acts as a bridge between the meteorological research community and operational forecasters by developing, evaluating and transitioning new technology and techniques to improve weather support to spaceport operations at the Eastern Range (ER) and Kennedy Space Center. Its primary customers are the 45th Weather Squadron at Cape Canaveral Air Force Station (CCAFS), the Spaceflight Meteorology Group at Johnson Space Center and the National Weather Service Office in Melbourne, FL. Its products are used to support NASA's Shuttle and ELV programs as well as Department of Defense and commercial launches from the ER. Shuttle support includes landing sites beyond the ER. The AMU is co-located with the Air Force operational forecasters at CCAFS to facilitate continuous two-way interaction between the AMU and its operational customers. It is operated under a NASA, Air Force, and NWS Memorandum of Understanding (MOU) by a competitively-selected contractor. The contract, which is funded and managed by NASA, provides five full time professionals with degrees in meteorology or related fields, some of whom also have operational experience. NASA provides a Ph.D.- level NASA civil service scientist as Chief of the AMU. The AMU is tasked by its customers through a unique, nationally recognized process. The tasks are limited to development, evaluation and operational transition of technology to improve weather support to spaceport operations and providing expert advice to the customers. The MOU expressly forbids using the AMU resources to conduct operations or do basic research. The presentation will provide a brief overview of the AMU and how it is tasked by its customers to provide high priority products and services. The balance of the presentation will cover a sampling of products delivered over the last 18 years that are currently in operational use. Each example will describe the problem to be solved, the solution provided, and the operational benefits of implementing that solution.
The recent changes and topics in CONTRAIL project
NASA Astrophysics Data System (ADS)
Machida, Toshinobu; Umezawa, Taku; Sawa, Yousuke; Niwa, Yosuke; Matsueda, Hidekazu
2016-04-01
CONTRAIL (Comprehensive Observation Network for TRace gases by AIrLiner) project has been conducted since 2005 with Continuous CO2 Measuring Equipment (CME) and Automatic air Sampling Equipment (ASE) onboard commercial airliners for observations of atmospheric greenhouse gases. Japan Airlines (JAL) offers eight Boeing 777-200ER airplanes modified for CONTRAIL; CME and ASE can be installed on all and five of them, respectively. ASE measurements have provided the long records of greenhouse gases in the upper troposphere along the flight route between Japan and Australia. In addition, we started a new sampling program between Japan and Europe in 2012 to obtain data at higher latitudes and the UT/LS region. When the 777-200ER airplane was not operated for the observation route, we used Manual air Sampling Equipment (MSE) for taking air onboard as substitute for ASE. Since flight routes with 777-200ER have been restricted only to Asian countries and Hawaii in the last few years, additional two Boeing 777-300ERs were modified to install CME and expand area coverage of CO2 observations to Europe, Australia and the east coast of US in 2015-2016. We also present our recent data analysis for intensive CME observations over Delhi, India, which indicates a significant impact of Indian wintertime agriculture on the regional carbon budget.
NASA Astrophysics Data System (ADS)
Lattin, Frank G.; Paul, Donald G.
1996-11-01
A sorbent-based gas chromatographic method provides continuous quantitative measurement of phosgene, hydrogen cyanide, and cyanogen chloride in ambient air. These compounds are subject to workplace exposure limits as well as regulation under terms of the Chemical Arms Treaty and Title III of the 1990 Clean Air Act amendments. The method was developed for on-sit use in a mobile laboratory during remediation operations. Incorporated into the method are automated multi-level calibrations at time weighted average concentrations, or lower. Gaseous standards are prepared in fused silica lined air sampling canisters, then transferred to the analytical system through dynamic spiking. Precision and accuracy studies performed to validate the method are described. Also described are system deactivation and passivation techniques critical to optimum method performance.
An indoor air quality study of an alligator (Alligator mississippiensis) holding facility.
Wilson, S C; Holder, H W; Martin, J M; Brasel, T L; Andriychuk, L A; Wu, C; Straus, D C; Aguilar, R
2006-06-01
An environmental microbiologic investigation was conducted in an alligator (Alligator mississippiensis) holding facility in a zoo in the southeastern U.S. The facility had housed five alligators between March 1999 and February 2005. In the exhibit, one alligator died and all experienced poor health. It was hypothesized that environmental microbial contamination was associated with these issues. Samples were collected for fungal identification and quantification, microcystin analysis, and airborne mycotoxins. Analyses of air and water were conducted and an examination of the heating, ventilation, and air-conditioning system (HVAC) for design, maintenance, and operating issues was made. Two control sites, a facility for false gharials (Tomistoma schlegelii) and an off-site alligator breeding facility, were also tested. Morbidity and mortality records were examined for all sites. Results showed that, compared to the control sites, the test alligator facility and its HVAC system were extensively contaminated with a range of fungi. Nearly all sampled surfaces featured fungal growth. There were also significantly higher counts of Penicillium/Aspergillus-like and Chrysosporium-like spores in the air (P < 0.004). The design, maintenance, and operation of the HVAC system were all inadequate, resulting in poorly conditioned and mold-contaminated air being introduced to the facility. Morbidity records revealed solitary pulmonary disorders over time in three alligators, with one dying as a result. The other two alligators suffered from general malaise and a range of nonspecific symptoms. The control facilities had no morbidity or mortality issues. In conclusion, although no causal links could be demonstrated because of the nature of the morbidity data, environmental mold contamination appeared to be associated with the history of morbidity and mortality in the alligator exhibit.
Monitoring of the Atmosphere on the International Space Station with the Air Quality Monitor
NASA Technical Reports Server (NTRS)
Wallace William T.; Limero, Thomas F.; Loh, Leslie J.; Mudgett, Paul D.; Gazda, Daniel B.
2017-01-01
During the early years of human spaceflight, short duration missions allowed for monitoring of the spacecraft environment to be performed via archival sampling, in which samples were returned to Earth for analysis. With the construction of the International Space Station (ISS) and the accompanying extended mission durations, the need for enhanced, real-time monitors became apparent. The Volatile Organic Analyzer (VOA) operated on ISS for 7 years, where it assessed trace volatile organic compounds in the cabin air. The large and fixed-position VOA was eventually replaced with the smaller Air Quality Monitor (AQM). Since March 2013, the atmosphere of the U.S. Operating Segment (USOS) has been monitored in near real-time by a pair of AQMs. These devices consist of a gas chromatograph (GC) coupled with a differential mobility spectrometer (DMS) and currently target detection list of 22 compounds. These targets are of importance to both crew health and the Environmental Control and Life Support Systems (ECLSS) on ISS. Data is collected autonomously every 73 hours, though the units can be controlled remotely from mission control to collect data more frequently during contingency or troubleshooting operations. Due to a nominal three-year lifetime on-orbit, the initial units were replaced in February 2016. This paper will focus on the preparation and use of the AQMs over the past several years. A description of the technical aspects of the AQM will be followed by lessons learned from the deployment and operation of the first set of AQMs. These lessons were used to improve the already-excellent performance of the instruments prior to deployment of the replacement units. Data trending over the past several years of operation on ISS will also be discussed, including data obtained during a survey of the USOS modules. Finally, a description of AQM use for contingency and investigative studies will be presented.
Rosenberger, Wolfgang; Beckmann, Bibiana; Wrbitzky, Renate
2016-04-15
This paper presents the strategy and results of in-flight measurements of airborne aldehydes during normal operation and reported "smell events" on commercial aircraft. The aldehyde-measurement is a part of a large-scale study on cabin-air quality. The aims of this study were to describe cabin-air quality in general and to detect chemical abnormalities during the so-called "smell-events". Adsorption and derivatization of airborne aldehydes on 2,4-dinitrophenylhydrazine coated silica gel (DNPH-cartridge) was applied using tailor-made sampling kits. Samples were collected with battery supplied personal air sampling pumps during different flight phases. Furthermore, the influence of ozone was investigated by simultaneous sampling with and without ozone absorption unit (ozone converter) assembled to the DNPH-cartridges and found to be negligible. The method was validated for 14 aldehydes and found to be precise (RSD, 5.5-10.6%) and accurate (recovery, 98-103 %), with LOD levels being 0.3-0.6 μg/m(3). According to occupational exposure limits (OEL) or indoor air guidelines no unusual or noticeable aldehyde pollution was observed. In total, 353 aldehyde samples were taken from two types of aircraft. Formaldehyde (overall average 5.7 μg/m(3), overall median 4.9 μg/m(3), range 0.4-44 μg/m(3)), acetaldehyde (overall average 6.5 μg/m(3), overall median 4.6, range 0.3-90 μg/m(3)) and mostly very low concentrations of other aldehydes were measured on 108 flights. Simultaneous adsorption and derivatization of airborne aldehydes on DNPH-cartridges to the Schiff bases and their HPLC analysis with UV absorbance detection is a useful method to measure aldehydes in cabin-air of commercial aircraft. Copyright © 2015 Elsevier B.V. All rights reserved.
Sensor-triggered sampling to determine instantaneous airborne vapor exposure concentrations.
Smith, Philip A; Simmons, Michael K; Toone, Phillip
2018-06-01
It is difficult to measure transient airborne exposure peaks by means of integrated sampling for organic chemical vapors, even with very short-duration sampling. Selection of an appropriate time to measure an exposure peak through integrated sampling is problematic, and short-duration time-weighted average (TWA) values obtained with integrated sampling are not likely to accurately determine actual peak concentrations attained when concentrations fluctuate rapidly. Laboratory analysis for integrated exposure samples is preferred from a certainty standpoint over results derived in the field from a sensor, as a sensor user typically must overcome specificity issues and a number of potential interfering factors to obtain similarly reliable data. However, sensors are currently needed to measure intra-exposure period concentration variations (i.e., exposure peaks). In this article, the digitized signal from a photoionization detector (PID) sensor triggered collection of whole-air samples when toluene or trichloroethylene vapors attained pre-determined levels in a laboratory atmosphere generation system. Analysis by gas chromatography-mass spectrometry of whole-air samples (with both 37 and 80% relative humidity) collected using the triggering mechanism with rapidly increasing vapor concentrations showed good agreement with the triggering set point values. Whole-air samples (80% relative humidity) in canisters demonstrated acceptable 17-day storage recoveries, and acceptable precision and bias were obtained. The ability to determine exceedance of a ceiling or peak exposure standard by laboratory analysis of an instantaneously collected sample, and to simultaneously provide a calibration point to verify the correct operation of a sensor was demonstrated. This latter detail may increase the confidence in reliability of sensor data obtained across an entire exposure period.
14 CFR 136.35 - Prohibition of commercial air tour operations over the Rocky Mountain National Park.
Code of Federal Regulations, 2013 CFR
2013-01-01
... operations over the Rocky Mountain National Park. 136.35 Section 136.35 Aeronautics and Space FEDERAL... COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS COMMERCIAL AIR TOURS AND NATIONAL PARKS AIR TOUR MANAGEMENT National Parks Air Tour Management § 136.35 Prohibition of commercial air tour operations over the Rocky...
14 CFR 136.35 - Prohibition of commercial air tour operations over the Rocky Mountain National Park.
Code of Federal Regulations, 2012 CFR
2012-01-01
... operations over the Rocky Mountain National Park. 136.35 Section 136.35 Aeronautics and Space FEDERAL... COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS COMMERCIAL AIR TOURS AND NATIONAL PARKS AIR TOUR MANAGEMENT National Parks Air Tour Management § 136.35 Prohibition of commercial air tour operations over the Rocky...
14 CFR 136.35 - Prohibition of commercial air tour operations over the Rocky Mountain National Park.
Code of Federal Regulations, 2014 CFR
2014-01-01
... operations over the Rocky Mountain National Park. 136.35 Section 136.35 Aeronautics and Space FEDERAL... COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS COMMERCIAL AIR TOURS AND NATIONAL PARKS AIR TOUR MANAGEMENT National Parks Air Tour Management § 136.35 Prohibition of commercial air tour operations over the Rocky...
14 CFR 136.35 - Prohibition of commercial air tour operations over the Rocky Mountain National Park.
Code of Federal Regulations, 2010 CFR
2010-01-01
... operations over the Rocky Mountain National Park. 136.35 Section 136.35 Aeronautics and Space FEDERAL... COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS COMMERCIAL AIR TOURS AND NATIONAL PARKS AIR TOUR MANAGEMENT National Parks Air Tour Management § 136.35 Prohibition of commercial air tour operations over the Rocky...
14 CFR 136.35 - Prohibition of commercial air tour operations over the Rocky Mountain National Park.
Code of Federal Regulations, 2011 CFR
2011-01-01
... operations over the Rocky Mountain National Park. 136.35 Section 136.35 Aeronautics and Space FEDERAL... COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS COMMERCIAL AIR TOURS AND NATIONAL PARKS AIR TOUR MANAGEMENT National Parks Air Tour Management § 136.35 Prohibition of commercial air tour operations over the Rocky...
Ram-air sample collection device for a chemical warfare agent sensor
Megerle, Clifford A.; Adkins, Douglas R.; Frye-Mason, Gregory C.
2002-01-01
In a surface acoustic wave sensor mounted within a body, the sensor having a surface acoustic wave array detector and a micro-fabricated sample preconcentrator exposed on a surface of the body, an apparatus for collecting air for the sensor, comprising a housing operatively arranged to mount atop the body, the housing including a multi-stage channel having an inlet and an outlet, the channel having a first stage having a first height and width proximate the inlet, a second stage having a second lower height and width proximate the micro-fabricated sample preconcentrator, a third stage having a still lower third height and width proximate the surface acoustic wave array detector, and a fourth stage having a fourth height and width proximate the outlet, where the fourth height and width are substantially the same as the first height and width.
[An AIDS-related cognitive map in a sample of drug abusers in Buenos Aires City].
Kornblit, A L; Bilyk, A
1990-01-01
This paper is an approach to AIDS as a topic among a drug abusers sample of the city of Buenos Aires. Research was carried out on the basis of a qualitative methodology. In an attempt at surveying opinions and attitudes of such a sample as regards AIDS (i.e. subjects' cognitive map), 21 drug abusers from three different rehabilitation programs operating in the B.A. area were interviewed. On the basis of the research performed, the authors elaborate communication strategies among drug abusers that would be helpful for authorities engaged in AIDS prevention to adopt. To boost a strategy likely to break up the AIDS-drug association existing in the mind of many an abuser would be highly advisable so that a separation be settled between both representations, thus giving drug abusers a higher motivation for self-care practice.
Shower disc sampling and the angular resolution of gamma-ray shower detectors
NASA Technical Reports Server (NTRS)
Lambert, A.; Lloyd-Evans, J.
1985-01-01
As part of the design study for the new UHE gamma ray detector being constsructed at Haverah Park, a series of experiments using scintillators operated side-by-side in 10 to the 15th power eV air showers are undertaken. Investigation of the rms sampling fluctuations in the shower disc arrival time yields an upper limit to the intrinsic sampling uncertainty, sigma sub rms = (1.1 + or - 0.1)ns, implying an angular resolution capability 1 deg for an inter-detector spacing of approximately 25 m.
A new study of shower age distribution in near vertical showers by EAS air shower array
NASA Technical Reports Server (NTRS)
Chaudhuri, N.; Basak, D. K.; Goswami, G. C.; Ghosh, B.
1984-01-01
The air shower array has been developed since it started operation in 1931. The array covering an area of 900 sq m now incorporates 21 particle density sampling detectors around two muon magnetic spectrographs. The air showers are detected in the size range 10 to the 4th power to 10 to the 6th power particles. A total of 11000 showers has so far been detected. Average values of shower age have been obtained in various shower size ranges to study the dependence of shower age on shower size. The core distance dependence of shower age parameter has also been analyzed for presentation.
Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1987
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1988-04-01
This report describes the environmental radiological monitoring programs conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1987. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstreams from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 3 refs., 2 figs., 34 tabs.« less
Browns Ferry Nuclear Plant annual radiological environmental operating report, 1990
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1991-04-01
This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1990. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 4 refs., 2 figs., 2 tabs.« less
Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1989
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-04-01
This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant (BFN) in 1989. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiationmore » levels. Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts if plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in river sediment would result in no measurable increase over background in the dose to the general public. 4 refs., 2 figs., 2 tabs.« less
Annual radiological environmental operating report, Browns Ferry Nuclear Plant, 1988
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-04-01
This report describes the environmental radiological monitoring program conducted by TVA in the vicinity of Browns Ferry Nuclear Plant in 1988. The program includes the collection of samples from the environment and the determination of the concentrations of radioactive materials in the samples. Samples are taken from stations in the general area of the plant and from areas not influenced by plant operations. Station locations are selected after careful consideration of the weather patterns and projected radiation doses to the various areas around the plant. Material sampled includes air, water, milk, foods, vegetation, soil, fish, sediment, and direct radiation levels.more » Results from stations near the plant are compared with concentrations from control stations and with preoperational measurements to determine potential impacts of plant operations. The vast majority of the exposures calculated from environmental samples were contributed by naturally occurring radioactive materials or from materials commonly found in the environment as a result of atmospheric nuclear weapons fallout. Small amounts of Co-60 were found in sediment samples downstream from the plant. This activity in stream sediment would result in no measurable increase over background in the dose to the general public. 3 refs., 2 figs., 2 tabs.« less
Fatigue and associated performance decrements in air transport operations
NASA Technical Reports Server (NTRS)
Lyman, E. G.; Orlady, H. W.
1981-01-01
A study of safety reports was conducted to examine the hypothesis that fatigue and associated performance decrements occur in air transport operations, and that these are associated with some combination of factors: circadian desynchronosis, duty time; pre-duty activity; sleep; work scheduling; workload; and environmental deprivation. The findings are based on a selected sample of reported incidents in which the reporter associated fatigue with the occurrence. In comparing the fatigue reports with a control set, significant performance decrements were found to exist related to time-of-day, awareness and attention to duty, less significantly, final phases of flights. The majority of the fatigue incidents involved such unsafe events as altitude deviations, takeoffs and landing without clearance, and the like. Considerations of duty and sleep are the major factors in the reported fatigue conditions.
A novel atmospheric tritium sampling system
NASA Astrophysics Data System (ADS)
Qin, Lailai; Xia, Zhenghai; Gu, Shaozhong; Zhang, Dongxun; Bao, Guangliang; Han, Xingbo; Ma, Yuhua; Deng, Ke; Liu, Jiayu; Zhang, Qin; Ma, Zhaowei; Yang, Guo; Liu, Wei; Liu, Guimin
2018-06-01
The health hazard of tritium is related to its chemical form. Sampling different chemical forms of tritium simultaneously becomes significant. Here a novel atmospheric tritium sampling system (TS-212) was developed to collect the tritiated water (HTO), tritiated hydrogen (HT) and tritiated methane (CH3T) simultaneously. It consisted of an air inlet system, three parallel connected sampling channels, a hydrogen supply module, a methane supply module and a remote control system. It worked at air flow rate of 1 L/min to 5 L/min, with temperature of catalyst furnace at 200 °C for HT sampling and 400 °C for CH3T sampling. Conversion rates of both HT and CH3T to HTO were larger than 99%. The collecting efficiency of the two-stage trap sets for HTO was larger than 96% in 12 h working-time without being blocked. Therefore, the collected efficiencies of TS-212 are larger than 95% for tritium with different chemical forms in environment. Besides, the remote control system made sampling more intelligent, reducing the operator's work intensity. Based on the performance parameters described above, the TS-212 can be used to sample atmospheric tritium in different chemical forms.
Carretta, Thomas R; King, Raymond E
2008-01-01
Over the past decade, the U.S. military has conducted several studies to evaluate determinants of enlisted air traffic controller (ATC) performance. Research has focused on validation of the Armed Services Vocational Aptitude Battery (ASVAB) and has shown it to be a good predictor of training performance. Despite this, enlisted ATC training and post-training attrition is higher than desirable, prompting interest in alternate selection methods to augment current procedures. The current study examined the utility of the FAA Air Traffic Selection and Training (AT-SAT) battery for incrementing the predictiveness of the ASVAB versus several enlisted ATC training criteria. Subjects were 448 USAF enlisted ATC students who were administered the ASVAB and FAA AT-SAT subtests and subsequently graduated or were eliminated from apprentice-level training. Training criteria were a dichotomous graduation/elimination training score, average ATC fundamentals course score, and FAA certified tower operator test score. Results confirmed the predictive validity of the ASVAB and showed that one of the AT-SAT subtests resembling a low-fidelity ATC work sample significantly improved prediction of training performance beyond the ASVAB alone. Results suggested training attrition could be reduced by raising the current ASVAB minimum qualifying score. However, this approach may make it difficult to identify sufficient numbers of trainees and lead to adverse impact. Although the AT-SAT ATC work sample subtest showed incremental validity to the ASVAB, its length (95 min) may be problematic in operational testing. Recommendations are made for additional studies to address issues affecting operational implementation.
NASA Astrophysics Data System (ADS)
Markovic, Milos Z.; Prokop, Sebastian; Staebler, Ralf M.; Liggio, John; Harner, Tom
2015-07-01
The particle infiltration efficiencies (PIE) of three passive and one active air samplers were evaluated under field conditions. A wide-range particle spectrometer operating in the 250-4140 nm range was used to acquire highly temporally resolved particle-number and size distributions for the different samplers compared to ambient air. Overall, three of the four evaluated samplers were able to acquire a representative sample of ambient particles with PIEs of 91.5 ± 13.7% for the GAPS Network sampler, 103 ± 15.5% for the Lancaster University sampler, and 89.6 ± 13.4% for a conventional PS-1 high-volume active air sampler (Hi-Vol). Significantly (p = 0.05) lower PIE of 54 ± 8.0% was acquired for the passive sampler used under the MONET program. These findings inform the comparability and use of passive and active samplers for measuring particle-associated priority chemicals in air.
Air contamination for predicting wound contamination in clean surgery: A large multicenter study.
Birgand, Gabriel; Toupet, Gaëlle; Rukly, Stephane; Antoniotti, Gilles; Deschamps, Marie-Noelle; Lepelletier, Didier; Pornet, Carole; Stern, Jean Baptiste; Vandamme, Yves-Marie; van der Mee-Marquet, Nathalie; Timsit, Jean-François; Lucet, Jean-Christophe
2015-05-01
The best method to quantify air contamination in the operating room (OR) is debated, and studies in the field are controversial. We assessed the correlation between 2 types of air sampling and wound contaminations before closing and the factors affecting air contamination. This multicenter observational study included 13 ORs of cardiac and orthopedic surgery in 10 health care facilities. For each surgical procedure, 3 microbiologic air counts, 3 particles counts of 0.3, 0.5, and 5 μm particles, and 1 bacteriologic sample of the wound before skin closure were performed. We collected data on surgical procedures and environmental characteristics. Of 180 particle counts during 60 procedures, the median log10 of 0.3, 0.5, and 5 μm particles was 7 (interquartile range [IQR], 6.2-7.9), 6.1 (IQR, 5.4-7), and 4.6 (IQR, 0-5.2), respectively. Of 180 air samples, 50 (28%) were sterile, 90 (50%) had 1-10 colony forming units (CFU)/m(3) and 40 (22%) >10 CFU/m(3). In orthopedic and cardiac surgery, wound cultures at closure were sterile for 24 and 9 patients, 10 and 11 had 1-10 CFU/100 cm(2), and 0 and 6 had >10 CFU/100 cm(2), respectively (P < .01). Particle sizes and a turbulent ventilation system were associated with an increased number of air microbial counts (P < .001), but they were not associated with wound contamination (P = .22). This study suggests that particle counting is a good surrogate of airborne microbiologic contamination in the OR. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
A comprehensive review of arsenic levels in the semiconductor manufacturing industry.
Park, Donguk; Yang, Haengsun; Jeong, Jeeyeon; Ha, Kwonchul; Choi, Sangjun; Kim, Chinyon; Yoon, Chungsik; Park, Dooyong; Paek, Domyung
2010-11-01
This paper presents a summary of arsenic level statistics from air and wipe samples taken from studies conducted in fabrication operations. The main objectives of this study were not only to describe arsenic measurement data but also, through a literature review, to categorize fabrication workers in accordance with observed arsenic levels. All airborne arsenic measurements reported were included in the summary statistics for analysis of the measurement data. The arithmetic mean was estimated assuming a lognormal distribution from the geometric mean and the geometric standard deviation or the range. In addition, weighted arithmetic means (WAMs) were calculated based on the number of measurements reported for each mean. Analysis of variance (ANOVA) was employed to compare arsenic levels classified according to several categories such as the year, sampling type, location sampled, operation type, and cleaning technique. Nine papers were found reporting airborne arsenic measurement data from maintenance workers or maintenance areas in semiconductor chip-making plants. A total of 40 statistical summaries from seven articles were identified that represented a total of 423 airborne arsenic measurements. Arsenic exposure levels taken during normal operating activities in implantation operations (WAM = 1.6 μg m⁻³, no. of samples = 77, no. of statistical summaries = 2) were found to be lower than exposure levels of engineers who were involved in maintenance works (7.7 μg m⁻³, no. of samples = 181, no. of statistical summaries = 19). The highest level (WAM = 218.6 μg m⁻³) was associated with various maintenance works performed inside an ion implantation chamber. ANOVA revealed no significant differences in the WAM arsenic levels among the categorizations based on operation and sampling characteristics. Arsenic levels (56.4 μg m⁻³) recorded during maintenance works performed in dry conditions were found to be much higher than those from maintenance works in wet conditions (0.6 μg m⁻³). Arsenic levels from wipe samples in process areas after maintenance activities ranged from non-detectable to 146 μg cm⁻², indicating the potential for dispersion into the air and hence inhalation. We conclude that workers who are regularly or occasionally involved in maintenance work have higher potential for occupational exposure than other employees who are in charge of routine production work. In addition, fabrication workers can be classified into two groups based on the reviewed arsenic exposure levels: operators with potential for low levels of exposure and maintenance engineers with high levels of exposure. These classifications could be used as a basis for a qualitative ordinal ranking of exposure in an epidemiological study.
[Determination a variety of acidic gas in air of workplace by Ion Chromatography].
Li, Shiyong
2014-10-01
To establish a method for determination of a variety of acid gas in the workplace air by Ion Chromatography. (hydrofluoric acid, hydrogen chloride or hydrochloric acid, sulfur anhydride or sulfuric acid, phosphoric acid, oxalic acid). The sample in workplace air was collected by the porous glass plate absorption tube containing 5 ml leacheate. (Sulfuric acid fog, phosphoric acid aerosol microporous membrane after collection, eluted with 5 ml of eluent.) To separated by AS14+AG14 chromatography column, by carbonate (2.0+1.0) mmol/L (Na(2)CO(3)-NaHCO(3)) as eluent, flow rate of 1 ml/min, then analyzed by electrical conductivity detector. The retain time was used for qualitative and the peak area was used for quantitation. The each ion of a variety of acid gas in the air of workplace were excellent in carbonate eluent separation. The linear range of working curve of 0∼20 mg/L. The correlation coefficient r>0.999; lower detection limit of 3.6∼115 µg/L; quantitative limit of 0.012∼0.53 mg/L; acquisition of 15L air were measured, the minimum detection concentration is 0.004 0∼0.13 mg/m(3). The recovery rate is 99.7%∼101.1%. In the sample without mutual interference ions. Samples stored at room temperature for 7 days. The same analysis method, the detection of various acidic gases in the air of workplace, simple operation, good separation effect, high sensitivity, high detection efficiency, easy popularization and application.
NASA Astrophysics Data System (ADS)
Bundke, Ulrich; Berg, Marcel; Franke, Harald; Zahn, Andreas; Boenisch, Harald; Perim de Faria, Julia; Berkes, Florian; Petzold, Andreas
2017-04-01
The European Research Infrastructure IAGOS (In-service Aircraft for a Global Observing System; www.iagos.org) responds to the increasing requests for long-term, routine in-situ observational data by using commercial passenger aircraft as measurement platforms. The infrastructure is built from two complementary approaches: The "CORE" component comprises the implementation and operation of autonomous instruments installed on up to 20 long-range aircraft of international airlines for continuous measurements of important reactive gases and greenhouse gases, as well as aerosol particles, dust and cloud particles. The fully automated instruments are designed for operation aboard the aircraft in unattended mode for several months and the data are transmitted automatically. The complementary "CARIBIC" component consists of the monthly deployment of a cargo container equipped with instrumentation for a larger suite of components. The CARIBIC container has equipment for measuring ozone, carbon monoxide, nitrogen oxides, water vapor and airborne particles. Furthermore the container is equipped with a system for collecting air samples. These air samples are analyzed in the laboratory. For each sample measurements for more than 40 trace gases including CFC's prohibited by the Montreal protocol, and all greenhouse gases are performed. The Interface described in this work is designed to host one of IAGOS CORE (Package2) instruments. Available are: P2a, P2b, measuring { NO_y} and {NO_x} em P2c, measuring the aerosol size-distribution (0.25
Priya, S; Srinivasan, P; Gopalakrishnan, R K
2012-01-01
The thoria dissolver, used for separation of (233)U from reactor-irradiated thorium metal and thorium oxide rods, is no longer operational. It was decided to carry out assessment of the radiological status of the dissolver cell for planning of the future decommissioning/dismantling operations. The dissolver interiors are expected to be contaminated with the dissolution remains of irradiated thorium oxide rods in addition to some of the partially dissolved thoria pellets. Hence, (220)Rn, a daughter product of (228)Th is of major radiological concern. Airborne activity of thoron daughters (212)Pb (Th-B) and (212)Bi (Th-C) was estimated by air sampling followed by high-resolution gamma spectrometry of filter papers. By measuring the full-energy peaks counts in the energy windows of (212)Pb, (212)Bi and (208)Tl, concentrations of thoron progeny in the sampled air were estimated by applying the respective intrinsic peak efficiency factors and suitable correction factors for the equilibration effects of (212)Pb and (212)Bi in the filter paper during the delay between sampling and counting. Then the thoron working level (TWL) was evaluated using the International Commission on Radiological Protection (ICRP) methodology. Finally, the potential effective dose to the workers, due to inhalation of thoron and its progeny during dismantling operations was assessed by using dose conversion factors recommended by ICRP. Analysis of filter papers showed a maximum airborne thoron progeny concentration of 30 TWLs inside the dissolver.
NASA Astrophysics Data System (ADS)
Pagano, T. S.
2016-12-01
Hyperspectral infrared sounding of the atmosphere has become a vital element in the observational system for weather forecast prediction at National Weather Prediction (NWP) centers worldwide. The NASA Atmospheric Infrared Sounder (AIRS) instrument was the pathfinder for the hyperspectral infrared observations and was designed to provide accurate atmospheric temperature and water vapor profile information in support of weather prediction. AIRS was launched in 2002 and continues to operate well. The Cross-track Infrared Sounder (CrIS) on the Suomi NPP satellite was launched in 2011 to continue the AIRS measurement record. CrIS also continues to operate well and additional sensors are planned for launch promising to continue the hyperspectral infrared measurements in support of NWP into the late 2030's. The high cost of IR sounders makes it costly to launch them into multiple orbits to improve temporal sampling, or into GEO, although EUMETSAT is planning a GEO IR Sounder to launch in the early 2020's. JPL NASA is offering an alternate hyperspectral IR sounder architecture for the future involving CubeSats. The latest technology in large format focal plane assemblies, wide field optics and active cryocoolers enables a reduction in size, mass and cost of the legacy sounders and offer new configurations. Lessons learned from AIRS and CrIS indicate that temperature and water vapor sounding in the lower troposphere can be achieved with only the MWIR portion of the spectrum. The CubeSat Infrared Atmospheric Sounder (CIRAS) employs only an MWIR spectrometer to achieve lower tropospheric temperature and water vapor profiles, but with comparable spatial, spectral and radiometric sensitivity in this band as AIRS and CrIS. CIRAS operates from 4.08-5.13 µm with 625 channels and spectral resolution of 1.2-2.0 cm-1. CIRAS employs an immersion grating spectrometer making the optics incredibly compact, and HOT-BIRD detectors enabling good uniformity and operability over the large 512 x 640 element focal plane. The CIRAS is packaged in a 6U CubeSat and uses less than 14 W. This presentation will discuss the requirements, expected performance and state of development of the CIRAS and concepts for future space architectures. Technology advancements and retrieved product accuracy will also be included.
1984-11-01
FLOW CHART Complet List of Location/Shtes Evaluation of Past Operations at LUste SNMe * ~Potential Hazard to Healh WelareS Reglaor Agencon consolidat...siting studies were also a part of this tions, soil, groundwater sampling and large complex project. analysis, and remedial concept engi- neering. Project
Primary VOC emissions from Commercial Aircraft Jet Engines
NASA Astrophysics Data System (ADS)
Kilic, Dogushan; Huang, Rujin; Slowik, Jay; Brem, Benjamin; Durdina, Lukas; Rindlisbacher, Theo; Baltensperger, Urs; Prevot, Andre
2014-05-01
Air traffic is growing continuously [1]. The increasing number of airplanes leads to an increase of aviation emissions giving rise to environmental concerns globally by high altitude emissions and, locally on air quality at the ground level [2]. The overall impact of aviation emissions on the environment is likely to increase when the growing air transportation trend [2] is considered. The Aviation Particle Regulatory Instrumentation Demonstration Experiment (APRIDE)-5 campaign took place at Zurich Airport in 2013. In this campaign, aircraft exhaust is sampled during engine acceptance tests after engine overhaul at the facilities of SR Technics. Direct sampling from the engine core is made possible due to the unique fixed installation of a retractable sampling probe and the use of a standardized sampling system designed for the new particulate matter regulation in development for aircraft engines. Many of the gas-phase aircraft emissions, e.g. CO2, NOX, CO, SO2, hydrocarbons, and volatile organic compounds (VOC) were detected by the instruments in use. This study, part of the APRIDE-5 campaign, focuses on the primary VOC emissions in order to produce emission factors of VOC species for varying engine operating conditions which are the surrogates for the flight cycles. Previously, aircraft plumes were sampled in order to quantify VOCs by a proton transfer reaction quadrupole mass spectrometer (PTR-MS) [3]. This earlier study provided a preliminary knowledge on the emission of species such as methanol, acetaldehyde, acetone, benzene and toluene by varying engine thrust levels. The new setup was (i) designed to sample from the diluted engine exhaust and the new tool and (ii) used a high resolution time of flight PTR-MS with higher accuracy for many new species, therefore providing a more detailed and accurate inventory. We will present the emission factors for species that were quantified previously, as well as for many additional VOCs detected during the campaign. References 1."Annual Review 2013", International Air Transport Association (IATA) 2014, Page 8, available on: http://www.iata.org/about/Documents/iata-annual-review-2013-en.pdf. 2."Summary for Policymakers: IPCC Special Report Aviation and the Global Atmosphere", 1999, pp. 5-10. 3."Hydrocarbon emissions from in-use commercial aircraft during airport operations", Herndon S.C., Rogers T., Dunlea E.J., Jayne J.T., Miake-Lye R., Knighton B., Environ Sci. Technol. 2006 Jul 15;40(14):4406-13.
NASA Technical Reports Server (NTRS)
Peters, P. N.; Hester, H. B.; Bertsch, W.; Mayfield, H.; Zatko, D.
1983-01-01
An investigation involving sampling the rapidly changing environment of the Shuttle cargo bay is considered. Four time-integrated samples and one rapid acquisition sample were collected to determine the types and quantities of contaminants present during ascent and descent of the Shuttle. The sampling times for the various bottles were controlled by valves operated by the Data Acquisition and Control System (DACS) of the IECM. Many of the observed species were found to be common solvents used in cleaning surfaces. When the actual volume sampled is taken into account, the relative mass of organics sampled during descent is about 20 percent less than during ascent.
14 CFR 298.23 - Notifications to the Department of change in operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Registration for Exemption by Air Taxi Operators § 298.23 Notifications to the Department of change in operations. (a) If any of the information contained on its registration changes, an air taxi...
14 CFR 298.23 - Notifications to the Department of change in operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Registration for Exemption by Air Taxi Operators § 298.23 Notifications to the Department of change in operations. (a) If any of the information contained on its registration changes, an air taxi...
Shepherd, Daniel; Dirks, Kim; Welch, David; McBride, David; Landon, Jason
2016-08-06
Air pollution originating from road traffic is a known risk factor of respiratory and cardiovascular disease (both in terms of chronic and acute effects). While adverse effects on cardiovascular health have also been linked with noise (after controlling for air pollution), noise exposure has been commonly linked to sleep impairment and negative emotional reactions. Health is multi-faceted, both conceptually and operationally; Health-Related Quality of Life (HRQOL) is one of many measures capable of probing health. In this study, we examine pre-collected data from postal surveys probing HRQOL obtained from a variety of urban, suburban, and rural contexts across the North Island of New Zealand. Analyses focus on the covariance between air pollution annoyance and noise annoyances, and their independent and combined effects on HRQOL. Results indicate that the highest ratings of air pollution annoyance and noise annoyances were for residents living close to the motorway, while the lowest were for rural residents. Most of the city samples indicated no significant difference between air pollution- and noise-annoyance ratings, and of all of the correlations between air pollution- and noise-annoyance, the highest were found in the city samples. These findings suggest that annoyance is driven by exposure to environmental factors and not personality characteristics. Analysis of HRQOL indicated that air pollution annoyance predicts greater variability in the physical HRQOL domain while noise annoyance predicts greater variability in the psychological, social and environmental domains. The lack of an interaction effect between air pollution annoyance and noise annoyance suggests that air pollution and noise impact on health independently. These results echo those obtained from objective measures of health and suggest that mitigation of traffic effects should address both air and noise pollution.
Shepherd, Daniel; Dirks, Kim; Welch, David; McBride, David; Landon, Jason
2016-01-01
Air pollution originating from road traffic is a known risk factor of respiratory and cardiovascular disease (both in terms of chronic and acute effects). While adverse effects on cardiovascular health have also been linked with noise (after controlling for air pollution), noise exposure has been commonly linked to sleep impairment and negative emotional reactions. Health is multi-faceted, both conceptually and operationally; Health-Related Quality of Life (HRQOL) is one of many measures capable of probing health. In this study, we examine pre-collected data from postal surveys probing HRQOL obtained from a variety of urban, suburban, and rural contexts across the North Island of New Zealand. Analyses focus on the covariance between air pollution annoyance and noise annoyances, and their independent and combined effects on HRQOL. Results indicate that the highest ratings of air pollution annoyance and noise annoyances were for residents living close to the motorway, while the lowest were for rural residents. Most of the city samples indicated no significant difference between air pollution- and noise-annoyance ratings, and of all of the correlations between air pollution- and noise-annoyance, the highest were found in the city samples. These findings suggest that annoyance is driven by exposure to environmental factors and not personality characteristics. Analysis of HRQOL indicated that air pollution annoyance predicts greater variability in the physical HRQOL domain while noise annoyance predicts greater variability in the psychological, social and environmental domains. The lack of an interaction effect between air pollution annoyance and noise annoyance suggests that air pollution and noise impact on health independently. These results echo those obtained from objective measures of health and suggest that mitigation of traffic effects should address both air and noise pollution. PMID:27509512
14 CFR 330.29 - What information must air taxi operators submit on Form 330 (Final) and Form 330-C?
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false What information must air taxi operators... COMPENSATION OF AIR CARRIERS Application Procedures § 330.29 What information must air taxi operators submit on Form 330 (Final) and Form 330-C? As an air taxi operator, you must complete Form 330 (Final) in...
14 CFR 330.29 - What information must air taxi operators submit on Form 330 (Final) and Form 330-C?
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false What information must air taxi operators... COMPENSATION OF AIR CARRIERS Application Procedures § 330.29 What information must air taxi operators submit on Form 330 (Final) and Form 330-C? As an air taxi operator, you must complete Form 330 (Final) in...
Effect of ventilation rate on air cleanliness and energy consumption in operation rooms at rest.
Lee, Shih-Tseng; Liang, Ching-Chieh; Chien, Tsung-Yi; Wu, Feng-Jen; Fan, Kuang-Chung; Wan, Gwo-Hwa
2018-02-27
The interrelationships between ventilation rate, indoor air quality, and energy consumption in operation rooms at rest are yet to be understood. We investigate the effect of ventilation rate on indoor air quality indices and energy consumption in ORs at rest. The study investigates the air temperature, relative humidity, concentrations of carbon dioxide, particulate matter (PM), and airborne bacteria at different ventilation rates in operation rooms at rest of a medical center. The energy consumption and cost analysis of the heating, ventilating, and air conditioning (HVAC) system in the operation rooms at rest were also evaluated for all ventilation rates. No air-conditioned operation rooms had very highest PM and airborne bacterial concentrations in the operation areas. The bacterial concentration in the operation areas with 6-30 air changes per hour (ACH) was below the suggested level set by the United Kingdom (UK) for an empty operation room. A 70% of reduction in annual energy cost by reducing the ventilation rate from 30 to 6 ACH was found in the operation rooms at rest. Maintenance of operation rooms at ventilation rate of 6 ACH could save considerable amounts of energy and achieve the goal of air cleanliness.
A Discussion on Personnel Exposure to Posttest Byproducts from a 50-cal. Light Gas Gun
NASA Technical Reports Server (NTRS)
Henderson, Don; Rodriquez, Karen
2007-01-01
In January of 2002, employees working in the Hypervelocity Test Facility (HTF) at White Sands Test Facility (WSTF) began to notice common physical complaints. These included loss of smell, loss of taste, skin irritation, a burning sensation of the mucus membranes, and redness and chapping of the lips. These conditions extended to home during the weekends and throughout holiday breaks as well. Concerns about air contaminants were raised with regard to the operation of the .50-cal. two-stage light gas gun (2SLGG). Employees suspected that these conditions might be caused by air contaminants from small leaks at the gun pump tube joint at the breech, and exhaust gas entrainment into the WAC systems. The WSTF Industrial Hygienist (IH) was notified and samples were collected using the MIRAN infrared spectrometer (real time) air sampler on 08 January 2002 at the SO-cal. gun. The results from this screening test suggested the need for more detailed investigations with analytical sampling and analysis.
NASA Technical Reports Server (NTRS)
James, John T.; Limero, Tom; Beck, Steve; Martin, Millie; Covington, Phillip; Boyd, John; Peters, Randy
2003-01-01
Space-faring crews must have safe breathing air throughout their missions to ensure adequate performance and good health. Toxicological assessment of air quality depends on the standards that define acceptable air quality, measurements of pollutant levels during the flight, and reports from the crew on their in-flight perceptions of air quality. Air samples returned from ISS on flights 8A, UF2, 9A, and 11A were analyzed for trace pollutants. On average, the air during this period of operations was safe for human respiration. However, about 3 hours into the regeneration of 2 Metox canisters in the U.S. airlock on 20 February 2002 the crew reported an intolerable odor that caused them to stop the regeneration, take refuge in the Russian segment, and scrub air in the U.S. segment for 30 hours. Analytical data from grab samples taken during the incident showed that the pollutants released were characteristic of nominal air pollutants, but were present in much higher concentrations. The odors reported by the crew were due to relatively high concentrations of n-butanol, and possibly other pollutants in the mixture. Later data taken during regeneration of Metox canisters that had not been subject to long-term flows showed minimal effects on air quality. Long-term trending data suggest that a disruption in atmospheric mixing between the Service Module and the U.S. Laboratory has occurred and that formaldehyde concentrations are gradually increasing in the U.S. Laboratory. Trending data also show that the releases of octafluoropropane (OFP) have subsided.
Compaction and Permeability Reduction of Castlegate Sandstone under Pore Pressure Cycling
NASA Astrophysics Data System (ADS)
Bauer, S. J.
2014-12-01
We investigate time-dependent compaction and permeability changes by cycling pore pressure with application to compressed air energy storage (CAES) in a reservoir. Preliminary experiments capture the impacts of hydrostatic stress, pore water pressure, pore pressure cycling, chemical, and time-dependent considerations near a borehole in a CAES reservoir analog. CAES involves creating an air bubble in a reservoir. The high pressure bubble serves as a mechanical battery to store potential energy. When there is excess grid energy, bubble pressure is increased by air compression, and when there is energy needed on the grid, stored air pressure is released through turbines to generate electricity. The analog conditions considered are depth ~1 km, overburden stress ~20 MPa and a pore pressure ~10MPa. Pore pressure is cycled daily or more frequently between ~10 MPa and 6 MPa, consistent with operations of a CAES facility at this depth and may continue for operational lifetime (25 years). The rock can vary from initially fully-to-partially saturated. Pore pressure cycling changes the effective stress.Jacketed, room temperature tap water-saturated samples of Castlegate Sandstone are hydrostatically confined (20 MPa) and subjected to a pore pressure resulting in an effective pressure of ~10 MPa. Pore pressure is cycled between 6 to 10 MPa. Sample displacement measurements yielded determinations of volumetric strain and from water flow measurements permeability was determined. Experiments ran for two to four weeks, with 2 to 3 pore pressure cycles per day. The Castlegate is a fluvial high porosity (>20%) primarily quartz sandstone, loosely calcite cemented, containing a small amount of clay.Pore pressure cycling induces compaction (~.1%) and permeability decreases (~20%). The results imply that time-dependent compactive processes are operative. The load path, of increasing and decreasing pore pressure, may facilitate local loosening and grain readjustments that results in the compaction and permeability decreases observed. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Dept. of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.SAND2014-16586A
On evaluating compliance with air pollution levels not to be exceeded more than once per year
NASA Technical Reports Server (NTRS)
Neustadter, H. E.; Sidik, S. M.
1974-01-01
The adequacy is considered of currently practiced monitoring and data reduction techniques for assessing compliance with 24-hour Air Quality Standards (AQS) not to be exceeded more than once per year. The present situation for suspended particulates is discussed. The following conclusions are reached: (1) For typical less than daily sampling (i.e., 60 to 120 24-hour samples per year) the deviation from independence of the data set should not be substantial. (2) The interchange of exponentiation and expectation operations in the EPA data reduction model, underestimates the second highest level by about 4 to 8 percent for typical sigma values. (3) Estimates of the second highest pollution level have associated with them a large statistical variability arising from the finite size of the sample. The 0.95 confidence interval ranges from + or - 40 percent for 120 samples per year to + or - 84 percent for 30 samples per year. (4) The design value suggested by EPA for abatement and/or control planning purposes typically gives a margin of safety of 60 to 120 percent.
14 CFR 294.30 - Scope of service and equipment authorized.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS CANADIAN CHARTER AIR TAXI OPERATORS General Rules for... air service, and the exemption provided by this part to Canadian charter air taxi operators that... charter air taxi operator shall not use large aircraft for charter air service until it has been granted a...
Bacteriological evaluation of a down-draught necropsy table ventilation system.
al-Wali, W; Kibbler, C C; McLaughlin, J E
1993-01-01
AIMS--To evaluate the microbiological efficacy of a down-draught necropsy table ventilation system (which surrounds the cadaver with a "curtain" of air under continuous extraction) during post mortem procedures. METHODS--Air sampling was carried out both in the presence and absence of staff and cadaver and during a full post mortem procedure, with functioning and non-functioning table air extraction. The penetration of the air "curtain" was also examined during the use of an oscillating bone saw by means of a tracer organism, Bacillus subtilis var niger, painted on to the skull. RESULTS--There was little difference between bacterial counts obtained in the presence of staff only, staff plus cadaver, or during a post mortem examination. With all counts obtained, however, there was a two to three-fold reduction when the ventilation was in operation compared with when the extract duct was occluded. Using the tracer organism, a two to three log reduction in counts was shown when the "curtain" was in operation during the use of the oscillating bone saw. CONCLUSIONS--These results suggest that the system provides potential protection for post mortem room staff against airborne infections. PMID:8408701
NASA Astrophysics Data System (ADS)
Murphy, P. C.; Lerner, B. M.; Williams, E. J.
2003-12-01
Air measurements of CO2 were made with a LI-COR LI-7000 CO2/H2O analyzer on the NOAA ship Ronald H. Brown during the New England Air Quality Study (NEAQS 2002) field campaign. This instrument is an improved version of the older model LI-6262 CO2/H2O analyzer, which uses a non-dispersive IR radiation absorption technique. During NEAQS, we operated the LI-7000 without temperature regulation, using a simple 2-point calibration scheme. An intercomparison between our measurements of atmospheric CO2 mixing ratios and those measured by a more sophisticated method, using temperature-regulation and a multipoint calibration with a LI-6252 CO2 analyzer (operated by AOML) shows generally good results ([CO2]AL = [CO2]AOML x 1.015 (0.010) - 5.7 (3.8) ppmv; R2 = 0.9889) in highly variable air masses. During subsequent laboratory studies, we evaluated the instrument for the manufacturer's claims of improvement in signal noise, sample gas temperature equilibration and zero drift with temperature. Further work examined the instrument's susceptibility to rapid temperature changes, which has been previously demonstrated to introduce error of several ppmv ° C-1 in the LI-6252. A change in the LI-7000 optical bench temperature of 12 ° C in 1 hour caused a sampling error of ˜3 ppmv CO2. Therefore, our lab investigations indicate that the LI-7000 would benefit from a temperature-controlled enclosure, as is used by the AOML group.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anastas, M.Y.; Caplan, P.E.; Froehlich, P.A.
An on-site visit was made to the Ortho Pharmaceutical Corporation (OPC), Raritan, New Jersey to evaluate methods of controlling exposure to hazardous materials during the manufacturing of medications. OPC produced oral-contraceptive tablets containing norethindrone (NOR), mestranol, and ethynylestradiol (EE). Ventilation was an important engineering control at this site. Other engineering controls included the isolation of work procedures and automation of work practices for weighing ingredients, granulation of substances, tableting, and packaging. Area samples were taken for air monitoring of steroid concentration levels in each manufacturing area. Access to the work areas was only through the locker rooms. Samples taken inmore » the locker rooms revealed no detectable contaminant levels. Workers performing high risk activities wore air supplied vinyl suits and disposable rubber gloves. The vinyl suits had overshoes attached. For moderate risk activities the workers wore a disposable suit, rubber gloves and shoe covers. Appropriate respirators were provided. Workers in low risk activities wore disposable rubber gloves and appropriate respirators. Sampling indicated that processing workers experienced breathing-zone levels outside their vinyl suits of 16.40 and 0.36 micrograms/cubic meter of NOR and EE, respectively.« less
Reduction of hexavalent chromium collected on PVC filters.
Shin, Y C; Paik, N W
2000-01-01
Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidation-reduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 approximately 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 approximately 89.9) at 1 hour and 81.0% (78.3 approximately 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 approximately 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.
The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.
Strawsine, Ellen; Lutmer, Brian
2017-11-16
This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.
Duda, Izabela; Grzybowska, Konstancja; Jędrzejowska-Szypułka, Halina; Lewin-Kowalik, Joanna
2012-12-05
The sitting position during neurosurgical operations predisposes to air penetration through veins and the movement of the air through the pulmonary circulation. Contact of an air bubble with the endothelium can lead to acute lung injury. The presence of specific pulmonary proteins in the plasma such as surfactant protein D (SP-D) and Clara cell protein (CC16) is a biomarker of damaging processes at the air-blood barrier. The aim of our study was to examine the hypothesis that the level of investigated pulmonary biomarkers in plasma is higher in patients operated on in the sitting position. The study included patients undergoing planned neurosurgical operations, who were divided into two groups: the sitting group (40 patients, operated on in the sitting position) and the supine group (24 patients, operated in the supine position). After the operation blood samples were drawn, centrifuged, frozen and stored until analyses were conducted. The determination of the SP-D and CC16 levels was performed using an ELISA test. Air embolism (VAE) was defined as a sudden drop in etCO2 of more than 2 mmHg and the presence of air bubbles in the aspirated blood from the central cannula. In all patients, the number of hospitalization days in the postoperative period was calculated. There were no differences in the average levels of SP-D between the groups (the mean in the sitting group was 95.56 ng/mL and the mean in the supine group was 101.21 ng/mL). The average levels of CC16 were similar in both groups as well (6.56 ng/mL in the sitting group and 6.79 ng/mL in the supine group). There was a statistically significant positive correlation between SP-D and CC16 values in both groups. VAE was diagnosed clinically in 12.5% of cases in the sitting group without a significant increase in SP-D and CC16 levels. On average, patients in both groups were discharged from the hospital within 9 days of surgery. The sitting position and intraoperative VAE during neurosurgical procedures do not affect the concentration of plasma biomarkers of pulmonary parenchymal injury such as SP-D and CC16.
14 CFR 205.5 - Minimum coverage.
Code of Federal Regulations, 2011 CFR
2011-01-01
... commuter air carriers but excluding U.S. air taxi operators and Canadian charter air taxi operators, shall...,000 times 75 percent of the number of passenger seats installed in the aircraft. (c) U.S. air taxi... each occurrence for loss of or damage to property. (2) U.S. air taxi operators carrying passengers in...
14 CFR 205.5 - Minimum coverage.
Code of Federal Regulations, 2010 CFR
2010-01-01
... commuter air carriers but excluding U.S. air taxi operators and Canadian charter air taxi operators, shall...,000 times 75 percent of the number of passenger seats installed in the aircraft. (c) U.S. air taxi... each occurrence for loss of or damage to property. (2) U.S. air taxi operators carrying passengers in...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bibby, R; Guthrie, E
2009-01-30
The instrument has four collection vials that must be filled with ethylene glycol before operation. Each of the four vials should be labeled 1 through 4 and the empty weights recorded. Fill each vial with 80 mL of ethylene glycol and record the weight again. In order for the instrument to operate properly, the collection vials should always have less than 160 mL of total liquid in them. After completing a sample run, remove the collection vials, use a transfer pipette to remove any liquid that might still be on the air paddler, wipe off any condensation from the exteriormore » of the collection vial and record weight. From the instrument, record the ending volume and the time of operation. The solution mixed in the scintillation vial will be 2 ml of a 95% to 50% ethylene glycol to water mixture. To determine the efficiency of counting at all of these concentrations, a series of vials should be set up that consist of 18 ml of Ultima Gold LLT cocktail mixed with standard, regular deionized water and ethylene glycol. The efficiency curve should be counted in the 'Low Level' count mode with the Luminescence Correction ON and the Color Quench Correction ON. Once the tSIE values are determined, chart the cpm against the tSIE numbers and find the best fit for the data. The resulting equation is to be used to converting tSIE values from the collection vials to efficiency. To determine the background cpm value of the ethylene glycol, count a 2 ml sample of ethylene glycol with 18 ml of Ultima Gold for 100 minutes. To determine the total activity of the sample, take two 2 ml aliquots of sample from the first vial and place in separate scintillation vials. Record the weight of each aliquot. Determine the percentage of total sample each aliquot represents by dividing the aliquot weight by the total solution weight from the vial. Also, determine the percentage of ethylene glycol in the sample by dividing the initial solution weight by the final solution weight and multiplying by 100. Add 18 ml of Ultima Gold to each vial and proceed to count for 100 minutes in a 'Low Level' count mode. Before performing a calculation on the dpm value of each aliquot, a subtraction should be made for the background count rate of the ethylene glycol. Based on the background cpm, multiply the background cpm value by the percentage of ethylene glycol in the collection vial. Once the background value is subtracted, calculate the dpm value of the sample based on the tSIE conversion to efficiency. This will produce a dpm value. To convert this to a total activity of the sample, divide the aliquot dpm value by the decimal percentage of total sample the aliquot represents. This gives the total activity of the sample solution. Take the average of both aliquots as a final result. To convert the total activity from the solution in vial one to activity in air, an empirical formula is used to convert activity/gram from vial one to total activity introduced into the system. After calculation the final result for the vial, divide the total by the mass of the sample in vial one. This gives dpm/g (labeled C{sub m}). To convert this to total dpm measured, C = (128.59 * Cm + 10.837)/V Where: C = Tritium concentration in air (dpm/m{sup 3}) C{sub m} = measured tritium concentration from vial 1 (dpm/g) V = Volume of air sampled through instrument (m{sup 3}). C is the final value of tritium concentration in air.« less
Subtask 3.9 - Direct Coal Liquefaction Process Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aulich, Ted; Sharma, Ramesh
The Energy and Environmental Research Center (EERC), in partnership with the U.S. Department of Energy (DOE) and Accelergy Corporation, an advanced fuels developer with technologies exclusively licensed from ExxonMobil, undertook Subtask 3.9 to design, build, and preliminarily operate a bench-scale direct coal liquefaction (DCL) system capable of converting 45 pounds/hour of pulverized, dried coal to a liquid suitable for upgrading to fuels and/or chemicals. Fabrication and installation of the DCL system and an accompanying distillation system for off-line fractionation of raw coal liquids into 1) a naphtha middle distillate stream for upgrading and 2) a recycle stream was completed inmore » May 2012. Shakedown of the system was initiated in July 2012. In addition to completing fabrication of the DCL system, the project also produced a 500-milliliter sample of jet fuel derived in part from direct liquefaction of Illinois No. 6 coal, and submitted the sample to the Air Force Research Laboratory (AFRL) at Wright Patterson Air Force Base, Dayton, Ohio, for evaluation. The sample was confirmed by AFRL to be in compliance with all U.S. Air Force-prescribed alternative aviation fuel initial screening criteria.« less
Temperature dependence of corrosion of ferritic stainless steel in dual atmosphere at 600-800 °C
NASA Astrophysics Data System (ADS)
Alnegren, Patrik; Sattari, Mohammad; Svensson, Jan-Erik; Froitzheim, Jan
2018-07-01
The ferritic stainless steel AISI 441 (EN 1.4509) is exposed for 1000 h to air - 3% H2O on one side and to Ar - 5% H2 - 3% H2O on the other at temperatures 600, 700, and 800 °C. Conditions are chosen to mimic the environment of metallic interconnects in an operating solid oxide fuel cell (SOFC). At 600 °C, ∼25 μm thick Fe2O3/(Fe,Cr)3O4 forms on large parts of the air side of the samples. Reference samples exposed to air - 3% H2O on both sides form thin protective layers of (Cr,Mn)3O4/Cr2O3 at the same temperature. At higher temperatures, 700 and 800 °C, all samples form protective layers of (Cr,Mn)3O4/Cr2O3 regardless of exposure to single or dual atmosphere. It is concluded that corrosion resistance in a dual atmosphere has an inverse dependence on temperature. Different hypotheses for the underlying cause for the dual atmosphere effect are discussed and compared to the experimental data.
14 CFR 25.1527 - Ambient air temperature and operating altitude.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Ambient air temperature and operating... TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES Operating Limitations and Information Operating Limitations § 25.1527 Ambient air temperature and operating altitude. The extremes of...
Ojajärvi, J
1996-01-01
To determine whether a specially designed antisuction device can prevent the bacterial contamination of the drive air lines of the dental turbine that is caused by suction when the turbine is stopped. A dental unit with and without the antisuction device and three different types of sterilized handpieces were used in the tests. Each turbine was operated in air, then submerged into a bacterial suspension of E. coli and enterococci for 3 seconds, removed, and stopped. This procedure was repeated 10 times. Possible bacterial contamination of the drive air lines was examined by submersing the head of a sterilized handpiece with the turbine running into a nutrient broth for 30 seconds. The broth was incubated at 35 degrees C up to 2 days. After use of the conventional dental unit, bacterial growth of drive air lines was found in 10 of 150 broth samples. After the installation of the antisuction device no bacterial growth was found in any of the 138 samples. The difference in the contamination frequencies is statistically significant (p = 0.011, Fisher's two-sided exact test). The drive air lines of the turbine in the dental unit may become contaminated despite the sterilization of handpieces. The antisuction device installed into the dental unit was found to prevent the contamination. With the exception of possibly immunocompromised patients, the transmission of microbes by exhaust air may be too small to cause infections. However, transmission of oral material between patients should be prevented in dental practice.
Stratospheric measurements of ozone-depleting substances and greenhouse gases using AirCores
NASA Astrophysics Data System (ADS)
Laube, Johannes; Leedham Elvidge, Emma; Kaiser, Jan; Sturges, Bill; Heikkinen, Pauli; Laurila, Tuomas; Hatakka, Juha; Kivi, Rigel; Chen, Huilin; Fraser, Paul; van der Veen, Carina; Röckmann, Thomas
2017-04-01
Retrieving air samples from the stratosphere has previously required aircraft or large balloons, both of which are expensive to operate. The novel "AirCore" technique (Karion et al., 2010) enables stratospheric sampling using weather balloons, which is much more cost effective. AirCores are long (up to 200 m) stainless steel tubes which are placed as a payload on a small balloon, can ascend to over 30 km and fill upon descent, collecting a vertical profile of the atmosphere. Retrieved volumes are much smaller though, which presents a challenge for trace gas analysis. To date, only the more abundant trace gases such as carnon dioxide (CO2) and methane (CH4) have been quantified in AirCores. Halogenated trace gases are also important greenhouse gases and many also deplete stratospheric ozone. Their concentrations are however much lower i.e. typically in the part per trillion (ppt) molar range. We here present the first stratospheric measurements of halocarbons in AirCores obtained using UEA's highly sensitive (detection limits of 0.01-0.1 ppt in 10 ml of air) gas chromatography mass spectrometry system. The analysed air originates from a Stratospheric Air Sub-sampler (Mrozek et al., 2016) which collects AirCore segments after the non-destructive CO2 and CH4 analysis. Successfully measured species include CFC-11, CFC-12, CFC-113, CFC-115, H-1211, H-1301, HCFC-22, HCFC-141b, HCFC-142b, HCFC-133a, and sulphur hexafluoride (SF6). We compare the observed mixing ratios and precisions with data obtained from samples collected during various high-altitude aircraft campaigns between 2009 and 2016 as well as with southern hemisphere tropospheric long-term trends. As part of the ERC-funded EXC3ITE (EXploring stratospheric Composition, Chemistry and Circulation with Innovative Techniques) project more than 40 AirCore flights are planned in the next 3 years with an expanded range of up to 30 gases in order to explore seasonal and interannual variability in the stratosphere. References Karion et al., J. Atmos. Ocean. Technol., 27(11), 1839-1853, 2010 Mrozek et al., Atmos. Meas. Tech., 9, 5607-5620, 2016
14 CFR 291.20 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REGULATIONS CARGO OPERATIONS IN INTERSTATE AIR TRANSPORTATION General Rules for All-Cargo Air Transportation... transportation performed by air carriers certificated under sections 41102 or 41103 of the Statute. Section 41103... operations in interstate air transportation, whether provided on all-cargo or combination aircraft, operated...
Grové, T; Van Dyk, T; Franken, A; Du Plessis, J
2014-01-01
Silicosis and coal worker's pneumoconiosis are serious occupational respiratory diseases associated with the coal mining industry and the inhalation of respirable dusts containing crystalline silica. The purpose of this study (funded by the Mine Health and Safety Council of South Africa) was to evaluate the individual contributions of underground coal mining tasks to the respirable dust and respirable silica dust concentrations in an underground section by sampling the respirable dust concentrations at the intake and return of each task. The identified tasks were continuous miner (CM) cutting, construction, transfer of coal, tipping, and roof bolting. The respirable dust-generating hierarchy of the tasks from highest to lowest was: transfer of coal > CM right cutting > CM left cutting > CM face cutting > construction > roof bolting > tipping; and for respirable silica dust: CM left cutting > construction > transfer of coal > CM right cutting. Personal exposure levels were determined by sampling the exposures of workers performing tasks in the section. Respirable dust concentrations and low concentrations of respirable silica dust were found at the intake air side of the section, indicating that air entering the section is already contaminated. The hierarchy for personal respirable dust exposures was as follows, from highest to lowest: CM operator > cable handler > miner > roof bolt operator > shuttle car operator, and for respirable silica dust: shuttle car operator > CM operator > cable handler > roof bolt operator > miner. Dust control methods to lower exposures should include revision of the position of workers with regard to the task performed, positioning of the tasks with regard to the CM cutting, and proper use of the line curtains to direct ventilation appropriately. The correct use of respiratory protection should also be encouraged.
Incident-response monitoring technologies for aircraft cabin air quality
NASA Astrophysics Data System (ADS)
Magoha, Paul W.
Poor air quality in commercial aircraft cabins can be caused by volatile organophosphorus (OP) compounds emitted from the jet engine bleed air system during smoke/fume incidents. Tri-cresyl phosphate (TCP), a common anti-wear additive in turbine engine oils, is an important component in today's global aircraft operations. However, exposure to TCP increases risks of certain adverse health effects. This research analyzed used aircraft cabin air filters for jet engine oil contaminants and designed a jet engine bleed air simulator (BAS) to replicate smoke/fume incidents caused by pyrolysis of jet engine oil. Field emission scanning electron microscopy (FESEM) with X-ray energy dispersive spectroscopy (EDS) and neutron activation analysis (NAA) were used for elemental analysis of filters, and gas chromatography interfaced with mass spectrometry (GC/MS) was used to analyze used filters to determine TCP isomers. The filter analysis study involved 110 used and 90 incident filters. Clean air filter samples exposed to different bleed air conditions simulating cabin air contamination incidents were also analyzed by FESEM/EDS, NAA, and GC/MS. Experiments were conducted on a BAS at various bleed air conditions typical of an operating jet engine so that the effects of temperature and pressure variations on jet engine oil aerosol formation could be determined. The GC/MS analysis of both used and incident filters characterized tri- m-cresyl phosphate (TmCP) and tri-p-cresyl phosphate (TpCP) by a base peak of an m/z = 368, with corresponding retention times of 21.9 and 23.4 minutes. The hydrocarbons in jet oil were characterized in the filters by a base peak pattern of an m/z = 85, 113. Using retention times and hydrocarbon thermal conductivity peak (TCP) pattern obtained from jet engine oil standards, five out of 110 used filters tested had oil markers. Meanwhile 22 out of 77 incident filters tested positive for oil fingerprints. Probit analysis of jet engine oil aerosols obtained from BAS tests by optical particle counter (OPC) revealed lognormal distributions with the mean (range) of geometric mass mean diameter (GMMD) = 0.41 (0.39, 0.45) microm and geometric standard deviation (GSD), sigma g = 1.92 (1.87, 1.98). FESEM/EDS and NAA techniques found a wide range of elements on filters, and further investigations of used filters are recommended using these techniques. The protocols for air and filter sampling and GC/MS analysis used in this study will increase the options available for detecting jet engine oil on cabin air filters. Such criteria could support policy development for compliance with cabin air quality standards during incidents.
NASA Technical Reports Server (NTRS)
1972-01-01
A terminal area simulation is described which permits analysis and synthesis of current and advanced air traffic management system configurations including ground and airborne instrumentation and new and modified aircraft characteristics. Ground elements in the simulation include navigation aids, surveillance radars, communication links, air-route structuring, ATC procedures, airport geometries and runway handling constraints. Airborne elements include traffic samples with individual aircraft performance and operating characteristics and aircraft navigation equipment. The simulation also contains algorithms for conflict detection, conflict resolution, sequencing and pilot-controller data links. The simulation model is used to determine the sensitivities of terminal area traffic flow, safety and congestion to aircraft performance characteristics, avionics systems, and other ATC elements.
Pan, Maohua; Bonny, Tania S.; Loeb, Julia; Jiang, Xiao; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z. Hugh; Wu, Chang-Yu
2017-01-01
ABSTRACT The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the viable virus aerosol sampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses. PMID:29034325
Pan, Maohua; Bonny, Tania S; Loeb, Julia; Jiang, Xiao; Lednicky, John A; Eiguren-Fernandez, Arantzazu; Hering, Susanne; Fan, Z Hugh; Wu, Chang-Yu
2017-01-01
The dynamics and significance of aerosol transmission of respiratory viruses are still controversial, for the major reasons that virus aerosols are inefficiently collected by commonly used air samplers and that the collected viruses are inactivated by the collection method. Without knowledge of virus viability, infection risk analyses lack accuracy. This pilot study was performed to (i) determine whether infectious (viable) respiratory viruses in aerosols could be collected from air in a real world environment by the vi able v irus a erosol s ampler (VIVAS), (ii) compare and contrast the efficacy of the standard bioaerosol sampler, the BioSampler, with that of the VIVAS for the collection of airborne viruses in a real world environment, and (iii) gain insights for the use of the VIVAS for respiratory virus sampling. The VIVAS operates via a water vapor condensation process to enlarge aerosolized virus particles to facilitate their capture. A variety of viable human respiratory viruses, including influenza A H1N1 and H3N2 viruses and influenza B viruses, were collected by the VIVAS located at least 2 m from seated patients, during a late-onset 2016 influenza virus outbreak. Whereas the BioSampler when operated following our optimized parameters also collected virus aerosols, it was nevertheless overall less successful based on a lower frequency of virus isolation in most cases. This side-by-side comparison highlights some limitations of past studies based on impingement-based sampling, which may have generated false-negative results due to either poor collection efficiency and/or virus inactivation due to the collection process. IMPORTANCE The significance of virus aerosols in the natural transmission of respiratory diseases has been a contentious issue, primarily because it is difficult to collect or sample virus aerosols using currently available air sampling devices. We tested a new air sampler based on water vapor condensation for efficient sampling of viable airborne respiratory viruses in a student health care center as a model of a real world environment. The new sampler outperformed the industry standard device (the SKC BioSampler) in the collection of natural virus aerosols and in maintaining virus viability. These results using the VIVAS indicate that respiratory virus aerosols are more prevalent and potentially pose a greater inhalation biohazard than previously thought. The VIVAS thus appears to be a useful apparatus for microbiology air quality tests related to the detection of viable airborne viruses.
Feasibility of an Air Liaison Officer Career Field: Improving the Theater Air-Ground System
2008-01-01
for Plans and Operations ALO air liaison officer AMLO air mobility liaison officer ANG Air National Guard ASOC air support operations center ASOG air...liaison officers ( AMLOs ) to liaison elements at Army corps, division, and other jointly validated headquarters to provide air mobility liaison. 1
Prevalences of Intimate Partner Violence in a Representative U.S. Air Force Sample
ERIC Educational Resources Information Center
Foran, Heather M.; Smith Slep, Amy M.; Heyman, Richard E.
2011-01-01
Objective: Intimate partner violence (IPV) is a serious health concern, but little is known about prevalence of IPV in the armed forces, as military members cope with the pressures of long-standing operations. Furthermore, previous prevalence studies have been plagued by definitional issues; most studies have focused on acts of aggression without…
Operational Toxicology Research
2006-08-01
Activity Relationships CQSARs) assessments of Air Force chemicals. Assay samples Completed collected for biochemical and molecular endpoints and...techniques for perchlorate in water, groundwater, soil and biological matrices such as blood, urine , milk. thyroid and other tissues required for...in vivo laboratory animal experiments with a l710D70ll Toxicological Response in Urine Using variety of known target organ toxicants, collect urine
USDA-ARS?s Scientific Manuscript database
Simultaneous chemical and sensory analysis based on gas chromatography-mass spectrometry-olfactometry (GC-MS-O) of air samples from livestock operations is a very useful approach for quantification of target odorous gases and also for ranking of odorous compounds. This information can help link spec...
The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography electron capture detector (GC/ECD) of pesticides in a variety of matrices, including air, house dust, soil, handwipes, and surface wipes. Other SOP's detail the extract...
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography/mass spectrometry (GC/MS) of pesticides in a variety of matrices, including air, house dust, soil, and handwipes. This analysis involves automated gas GC/MS analysis us...
Sahmel, J; Devlin, K; Burns, A; Ferracini, T; Ground, M; Paustenbach, D
2013-01-01
Benzene, a known carcinogen, can be generated as a by-product during the use of petroleum-based raw materials in chemical manufacturing. The aim of this study was to analyze a large data set of benzene air concentration measurements collected over nearly 40 years during routine employee exposure monitoring at a petrochemical manufacturing facility. The facility used ethane, propane, and natural gas as raw materials in the production of common commercial materials such as polyethylene, polypropylene, waxes, adhesives, alcohols, and aldehydes. In total, 3607 benzene air samples were collected at the facility from 1962 to 1999. Of these, in total 2359 long-term (>1 h) personal exposure samples for benzene were collected during routine operations at the facility between 1974 and 1999. These samples were analyzed by division, department, and job title to establish employee benzene exposures in different areas of the facility over time. Sampling data were also analyzed by key events over time, including changes in the occupational exposure limits (OELs) for benzene and key equipment process changes at the facility. Although mean benzene concentrations varied according to operation, in nearly all cases measured benzene quantities were below the OEL in place at the time for benzene (10 ppm for 1974-1986 and 1 ppm for 1987-1999). Decreases in mean benzene air concentrations were also found when data were evaluated according to 7- to 10-yr periods following key equipment process changes. Further, an evaluation of mortality rates for a retrospective employee cohort (n = 3938) demonstrated that the average personal benzene exposures at this facility (0.89 ppm for the period 1974-1986 and 0.125 ppm for the period 1987-1999) did not result in increased standardized mortality ratio (SMRs) for diseases or malignancies of the lymphatic system. The robust nature of this data set provides comprehensive exposure information that may be useful for assessing human benzene exposures at similar facilities. The data also provide a basis for comparable measured exposure levels and the potential for adverse health effects. These data may also prove beneficial for comparing relative exposure potential for production versus nonproduction operations and the relationship between area and personal breathing zone samples.
Code of Federal Regulations, 2011 CFR
2011-01-01
... air carriers, including commuter air carriers and air taxi operators as defined in § 298.2 of this chapter, and foreign direct air carriers, including Canadian charter air taxi operators as defined in...
Code of Federal Regulations, 2010 CFR
2010-01-01
... air carriers, including commuter air carriers and air taxi operators as defined in § 298.2 of this chapter, and foreign direct air carriers, including Canadian charter air taxi operators as defined in...
Mitigating the Shortage of Special Operations Aviation By an Unconventional Approach
2017-12-01
Second World War, and the majority of air power theorists suggested that when technology finally caught up with the inherent ability of aviation, air...assessment of an American expert [Richard D. Newton, Joint Special Operations University] in air special operations at the Air Force’s annual Air Power ...scope and time in order to “seize, destroy, disrupt, capture, exploit, recover, or damage high value or high pay-off targets.”48 When these operations
[Splash basins are contaminated even during operations in a laminar air flow environment].
Christensen, Mikkel; Sundstrup, Mikkel; Larsen, Helle Raagaard; Olesen, Bente; Ryge, Camilla
2014-03-03
Few studies have investigated the potential contamination of splash basins and they have shown very divergent results: contamination ranging from 2.13% to 74% has been reported. This study set out to examine if splash basins used in a laminar air flow (LAF) environment during elective knee and hip arthroplasty constitute an unnecessary risk. Of the 49 cases sampled two cultures were positive (4%; 95% confidence interval = 0.49-13.9). We conclude that splash basins do get contaminated even in an LAF environment. Further studies with larger populations are needed to validate our findings.
Major Joint/Combined Operations
2008-01-01
Quarterly 3 (Winter 1993–1994), 74. 20 Andrew G. B. Vallance , The Air Weapon: Doctrines of Air Power Strategy and Operational Art (New York: St... Vallance , 94; and Donald L. McSwain, Air Campaign Planning for Contingency Operations (Maxwell Air Force Base, AL: Air War College, May 1989), 37. 23...require positive identification of friendly forces and positive control of aircraft. 36 Richard R. Muller, “Close Air Support: The German, British
The U.S. Commercial Air Tour Industry: A Review of Aviation Safety Concerns
Ballard, Sarah-Blythe
2016-01-01
The U.S. Title 14 Code of Federal Regulations defines commercial air tours as “flight[s] conducted for compensation or hire in an airplane or helicopter where a purpose of the flight is sightseeing.” The incidence of air tour crashes in the United States is disproportionately high relative to similar commercial aviation operations, and air tours operating under Part 91 governance crash significantly more than those governed by Part 135. This paper reviews the government and industry response to four specific areas of air tour safety concern: surveillance of flight operations, pilot factors, regulatory standardization, and maintenance quality assurance. It concludes that the government and industry have successfully addressed many of these tenet issues, most notably by: advancing the operations surveillance infrastructure through implementation of en route, ground-based, and technological surveillance methods; developing Aeronautical Decision Making and cue-based training programs for air tour pilots; consolidating federal air tour regulations under Part 136; and developing public-private partnerships for raising maintenance operating standards and improving quality assurance programs. However, opportunities remain to improve air tour safety by: increasing the number and efficiency of flight surveillance programs; addressing pilot fatigue with more restrictive flight hour limitations for air tour pilots; ensuring widespread uptake of maintenance quality assurance programs, especially among high-risk operators not currently affiliated with private air tour safety programs; and eliminating the 25-mile exception allowing Part 91 operators to conduct commercial air tours without the safety oversight required of Part 135 operators. PMID:24597160
The U.S. commercial air tour industry: a review of aviation safety concerns.
Ballard, Sarah-Blythe
2014-02-01
The U.S. Title 14 Code of Federal Regulations defines commercial air tours as "flight[s] conducted for compensation or hire in an airplane or helicopter where a purpose of the flight is sightseeing." The incidence of air tour crashes in the United States is disproportionately high relative to similar commercial aviation operations, and air tours operating under Part 91 governance crash significantly more than those governed by Part 135. This paper reviews the government and industry response to four specific areas of air tour safety concern: surveillance of flight operations, pilot factors, regulatory standardization, and maintenance quality assurance. It concludes that the government and industry have successfully addressed many of these tenet issues, most notably by: advancing the operations surveillance infrastructure through implementation of en route, ground-based, and technological surveillance methods; developing Aeronautical Decision Making and cue-based training programs for air tour pilots; consolidating federal air tour regulations under Part 136; and developing public-private partnerships for raising maintenance operating standards and improving quality assurance programs. However, opportunities remain to improve air tour safety by: increasing the number and efficiency of flight surveillance programs; addressing pilot fatigue with more restrictive flight hour limitations for air tour pilots; ensuring widespread uptake of maintenance quality assurance programs, especially among high-risk operators not currently affiliated with private air tour safety programs; and eliminating the 25-mile exception allowing Part 91 operators to conduct commercial air tours without the safety oversight required of Part 135 operators.
Yu, Quan; Zhang, Qian; Lu, Xinqiong; Qian, Xiang; Ni, Kai; Wang, Xiaohao
2017-12-05
The performance of a miniature mass spectrometer in atmospheric analysis is closely related to the design of its sampling system. In this study, a simplified vacuum electrospray ionization (VESI) source was developed based on a combination of several techniques, including the discontinuous atmospheric pressure interface, direct capillary sampling, and pneumatic-assisted electrospray. Pulsed air was used as a vital factor to facilitate the operation of electrospray ionization in the vacuum chamber. This VESI device can be used as an efficient atmospheric sampling interface when coupled with a miniature rectilinear ion trap (RIT) mass spectrometer. The developed VESI-RIT instrument enables regular ESI analysis of liquid, and its qualitative and quantitative capabilities have been characterized by using various solution samples. A limit of detection of 8 ppb could be attained for arginine in a methanol solution. In addition, extractive electrospray ionization of organic compounds can be implemented by using the same VESI device, as long as the gas analytes are injected with the pulsed auxiliary air. This methodology can extend the use of the proposed VESI technique to rapid and online analysis of gaseous and volatile samples.
Garrison, R A; Robertson, L D; Koehn, R D; Wynn, S R
1993-12-01
Commercial air duct sanitation services are advertised to the public as being effective in reducing indoor aeroallergen levels despite the absence of published supporting data. Eight residential heat-ventilation-air conditioning (HVAC) systems in six homes and seven HVAC systems in five homes in winter and summer, respectively, were sampled to determine fungal colony forming units (CFUs) prior to and after an HVAC sanitation procedure was performed by a local company. Two houses in which no sanitation procedure was performed served as controls in each study phase. Two sample sets were obtained at each HVAC system prior to cleaning in order to determine baseline CFU levels. The test HVAC systems were then cleaned, and the HVAC systems allowed to operate as desired by the residents. Posttreatment sampling was performed 48 hours and then weekly after cleaning for 8 weeks. The HVAC systems were analyzed by exposing sterile 2% malt extract media plates at a 90-degree angle to the air flow at the air supply and air return vents. The baseline CFUs were similar in the control and study houses. Eight weeks after sanitation, the study houses demonstrated an overall CFU reduction of 92% during winter and 84% during summer. No reduction in CFU values was observed over the 8-week study period for the houses selected as controls. Further, HVAC sanitation appeared to reduce the number of fungal colonies entering and leaving the HVAC system, suggesting that the HVAC contained a significant percentage of the total fungal load in these homes. These data suggest that HVAC sanitation may be an effective tool in reducing airborne fungal populations in residential environments.
14 CFR 291.31 - Exemptions from the Statute.
Code of Federal Regulations, 2010 CFR
2010-01-01
... PROCEEDINGS) ECONOMIC REGULATIONS CARGO OPERATIONS IN INTERSTATE AIR TRANSPORTATION Exemptions for Cargo Operations in Interstate Air Transportation § 291.31 Exemptions from the Statute. (a) Each section 41102 or 41103 air carrier providing cargo operations in interstate air transportation is, with respect to such...
The carbon footprint of Australian ambulance operations.
Brown, Lawrence H; Canyon, Deon V; Buettner, Petra G; Crawford, J Mac; Judd, Jenni
2012-12-01
To determine the greenhouse gas emissions associated with the energy consumption of Australian ambulance operations, and to identify the predominant energy sources that contribute to those emissions. A two-phase study of operational and financial data from a convenience sample of Australian ambulance operations to inventory their energy consumption and greenhouse gas emissions for 1 year. State- and territory-based ambulance systems serving 58% of Australia's population and performing 59% of Australia's ambulance responses provided data for the study. Emissions for the participating systems totalled 67 390 metric tons of carbon dioxide equivalents. For ground ambulance operations, emissions averaged 22 kg of carbon dioxide equivalents per ambulance response, 30 kg of carbon dioxide equivalents per patient transport and 3 kg of carbon dioxide equivalents per capita. Vehicle fuels accounted for 58% of the emissions from ground ambulance operations, with the remainder primarily attributable to electricity consumption. Emissions from air ambulance transport were nearly 200 times those for ground ambulance transport. On a national level, emissions from Australian ambulance operations are estimated to be between 110 000 and 120 000 tons of carbon dioxide equivalents each year. Vehicle fuels are the primary source of emissions for ground ambulance operations. Emissions from air ambulance transport are substantially higher than those for ground ambulance transport. © 2012 The Authors. EMA © 2012 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.
Strange bedfellows: The curious case of STAR and Moata
NASA Astrophysics Data System (ADS)
Smith, A. M.; Levchenko, V. A.; Malone, G.
2013-01-01
The 2 MV tandem accelerator named ‘STAR’ was installed at ANSTO in 2003 and commissioned in 2004. It is used for ion beam analysis (IBA) and for radiocarbon measurements by accelerator mass spectrometry (AMS). Convenient space for the accelerator was found in the same building occupied by the decommissioned Argonaut-class nuclear reactor ‘Moata’; the name derives from the aboriginal word for ‘fire stick’ or ‘gentle fire’, appropriate for a 100 kW research reactor. This reactor operated between 1961 and 1995. In 2007 ANSTO’s Engineering Division assembled a team to dismantle and remove the reactor structure, along with its 12.1 tonnes of graphite reflector. The removal and remediation was completed in November 2010 and has won the team a number of prestigious awards. The entire operation was conducted inside a negatively-pressurised double-walled vinyl tent. An air curtain was positioned around the reactor core. The exhaust air from the tent passed through 2-stage HEPA filters before venting through an external stack. Neither ANSTO staff nor contractors received any significant radiation dose during the operation. Given the sensitivity of STAR for detection of 14C/12C (∼10-16) and the numerous routes for production of 14C in the reactor such as 13C(n, γ)14C, 14N(n, p)14C and 17O(n, α)14C there was the potential to directly contaminate the STAR environment with 14C. Furthermore, there was concern that reactor-14C could find its way from this building into the building where the radiocarbon sample preparation laboratories are located. This necessitated restrictions on staff movement between the buildings. We report on 14C control measurements made during and after the operation. These involved direct measurements on the reactor graphite and concrete bioshield, blank targets that were exposed in the building, swipe samples taken inside the tent and around the building and aerosol samples that were collected inside the building throughout the operation.
The Effects of Very Light Jet Air Taxi Operations on Commercial Air Traffic
NASA Technical Reports Server (NTRS)
Smith, Jeremy C.; Dollyhigh, Samuel M.
2006-01-01
This study investigates the potential effects of Very Light Jet (VLJ) air taxi operations adding to delays experienced by commercial passenger air transportation in the year 2025. The affordable cost relative to existing business jets and ability to use many of the existing small, minimally equipped, but conveniently located airports is projected to stimulate a large demand for the aircraft. The resulting increase in air traffic operations will mainly be at smaller airports, but this study indicates that VLJs have the potential to increase further the pressure of demand at some medium and large airports, some of which are already operating at or near capacity at peak times. The additional delays to commercial passenger air transportation due to VLJ air taxi operations are obtained from simulation results using the Airspace Concepts Evaluation System (ACES) simulator. The direct increase in operating cost due to additional delays is estimated. VLJs will also cause an increase in traffic density, and this study shows increased potential for conflicts due to VLJ operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
T. R. Saffle; R. G. Mitchell; R. B. Evans
The results of the various monitoring programs for 1998 indicated that radioactivity from the DOE's Idaho National Engineering and Environmental Laboratory (INEEL) operations could generally not be distinguished from worldwide fallout and natural radioactivity in the region surrounding the INEEL. Although some radioactive materials were discharged during INEEL operations, concentrations in the offsite environment and doses to the surrounding population were far less than state of Idaho and federal health protection guidelines. Gross alpha and gross beta measurements, used as a screening technique for air filters, were investigated by making statistical comparisons between onsite or boundary location concentrations and themore » distant community group concentrations. Gross alpha activities were generally higher at distant locations than at boundary and onsite locations. Air samples were also analyzed for specific radionuclides. Some human-made radionuclides were detected at offsite locations, but most were near the minimum detectable concentration and their presence was attributable to natural sources, worldwide fallout, and statistical variations in the analytical results rather than to INEEL operations. Low concentrations of 137Cs were found in muscle tissue and liver of some game animals and sheep. These levels were mostly consistent with background concentrations measured in animals sampled onsite and offsite in recent years. Ionizing radiation measured simultaneously at the INEEL boundary and distant locations using environmental dosimeters were similar and showed only background levels. The maximum potential population dose from submersion, ingestion, inhalation, and deposition to the approximately 121,500 people residing within an 80-km (50-mi) radius from the geographical center of the INEEL was estimated to be 0.08 person-rem (8 x 10-4 person-Sv) using the MDIFF air dispersion model. This population dose is less than 0.0002 percent of the estimated 43,7 00 person-rem (437 person-Sv) population dose from background radioactivity.« less
NASA Astrophysics Data System (ADS)
Yu, Lisan; Jin, Xiangze; Schulz, Eric W.; Josey, Simon A.
2017-08-01
This study analyzed shipboard air-sea measurements acquired by the icebreaker Aurora Australis during its off-winter operation in December 2010 to May 2012. Mean conditions over 7 months (October-April) were compiled from a total of 22 ship tracks. The icebreaker traversed the water between Hobart, Tasmania, and the Antarctic continent, providing valuable in situ insight into two dynamically important, yet poorly sampled, regimes: the sub-Antarctic Southern Ocean and the Antarctic marginal ice zone (MIZ) in the Indian Ocean sector. The transition from the open water to the ice-covered surface creates sharp changes in albedo, surface roughness, and air temperature, leading to consequential effects on air-sea variables and fluxes. Major effort was made to estimate the air-sea fluxes in the MIZ using the bulk flux algorithms that are tuned specifically for the sea-ice effects, while computing the fluxes over the sub-Antarctic section using the COARE3.0 algorithm. The study evidenced strong sea-ice modulations on winds, with the southerly airflow showing deceleration (convergence) in the MIZ and acceleration (divergence) when moving away from the MIZ. Marked seasonal variations in heat exchanges between the atmosphere and the ice margin were noted. The monotonic increase in turbulent latent and sensible heat fluxes after summer turned the MIZ quickly into a heat loss regime, while at the same time the sub-Antarctic surface water continued to receive heat from the atmosphere. The drastic increase in turbulent heat loss in the MIZ contrasted sharply to the nonsignificant and seasonally invariant turbulent heat loss over the sub-Antarctic open water.
NASA Astrophysics Data System (ADS)
Breton, D. J.; Koffman, B. G.; Kreutz, K. J.; Hamilton, G. S.
2010-12-01
Paleoclimate data are often extracted from ice cores by careful geochemical analysis of meltwater samples. The analysis of the microparticles found in ice cores can also yield unique clues about atmospheric dust loading and transport, dust provenance and past environmental conditions. Determination of microparticle concentration, size distribution and chemical makeup as a function of depth is especially difficult because the particle size measurement either consumes or contaminates the meltwater, preventing further geochemical analysis. Here we describe a microcontroller-based ice core melting system which allows the collection of separate microparticle and chemistry samples from the same depth intervals in the ice core, while logging and accurately depth-tagging real-time electrical conductivity and particle size distribution data. This system was designed specifically to support microparticle analysis of the WAIS Divide WDC06A deep ice core, but many of the subsystems are applicable to more general ice core melting operations. Major system components include: a rotary encoder to measure ice core melt displacement with 0.1 millimeter accuracy, a meltwater tracking system to assign core depths to conductivity, particle and sample vial data, an optical debubbler level control system to protect the Abakus laser particle counter from damage due to air bubbles, a Rabbit 3700 microcontroller which communicates with a host PC, collects encoder and optical sensor data and autonomously operates Gilson peristaltic pumps and fraction collectors to provide automatic sample handling, melt monitor control software operating on a standard PC allowing the user to control and view the status of the system, data logging software operating on the same PC to collect data from the melting, electrical conductivity and microparticle measurement systems. Because microparticle samples can easily be contaminated, we use optical air bubble sensors and high resolution ice core density profiles to guide the melting process. The combination of these data allow us to analyze melt head performance, minimize outer-to-inner fraction contamination and avoid melt head flooding. The WAIS Melt Monitor system allows the collection of real-time, sub-annual microparticle and electrical conductivity data while producing and storing enough sample for traditional Coulter-Counter particle measurements as well long term acid leaching of bioactive metals (e.g., Fe, Co, Cd, Cu, Zn) prior to chemical analysis.
Bellio, Alberto; Traversa, Amaranta; Adriano, Daniela; Bianchi, Daniela Manila; Colzani, Alberto; Gili, Stefano; Dondo, Alessandro; Gallina, Silvia; Grattarola, Carla; Maurella, Cristiana; Zoppi, Simona; Zuccon, Fabio; Decastelli, Lucia
2014-08-28
Campylobacteriosis was the most commonly reported zoonosis for confirmed human cases in European Union during 2011. Poultry meat was very often implicated in Campylobacter infections in humans. In Italy commerce of raw poultry meat is common in open-air markets: these areas can be considered at high risk of bacterial contamination due to the high presence birds like pigeons. The aim of this study was to collect data about the contamination by thermotolerant Campylobacter of raw poultry meat commercialised in open-air markets, of work-surfaces in contact with poultry meat and of pigeon stools sampled in the market areas in Turin, Northern Italy. Between September 2011 and December 2012, 86 raw poultry meat samples, 86 environmental swabs and 108 animal samples were collected in 38 open-air markets. Analysis were carried out according to ISO10272-1:2006 standard. C.coli was detected in 2.3% (2/86) of raw poultry meat samples, whereas no swab (0/86) resulted positive. Of pigeon stool 28% (30/107) was positive for C.jejuni (83.3% C.jejuni subsp . jejuni and 16.7% C.jejuni subsp . doylei ). C.jejuni subsp. jejuni was isolated from 1 dead pigeon . Our results showed lower rates of contamination than those reported at retail in Europe. Although samples were collected in areas at high risk of contamination, raw poultry meat and work surfaces reported a low level of presence of thermotolerant Campylobacter . The high percentage of C.jejuni isolated from pigeon stools showed the importance of a continuous application of preventive measures by the food business operators and the surveillance activity by the Competent Authority.
Performance of the University of Denver Low Turbulence, Airborne Aerosol Inlet in ACE-Asia
NASA Astrophysics Data System (ADS)
Lafleur, B.; Wilson, J. C.; Seebaugh, W. R.; Gesler, D.; Hilbert, H.; Mullen, J.; Reeves, J. M.
2002-12-01
The University of Denver Low Turbulence Inlet (DULTI) was flown on the NCAR C-130 in ACE-Asia. This inlet delivered large sample flows at velocities of a few meters per second at the exit of the inlet. This flow was slowed from the true air speed of the aircraft (100 to 150 m/s) to a few meters per second in a short diffuser with porous walls. The flow in the diffusing section was laminar. The automatic control system kept the inlet operating at near isokinetic intake velocities and in laminar flow for nearly all the flight time. The DULTI permits super micron particles to be sampled and delivered with high efficiency to the interior of the aircraft where they can be measured or collected. Because most of the air entering the inlet is removed through the porous medium, the sample flow experiences inertial enhancements. Because these enhancements occur in laminar flow, they are calculable using FLUENT. Enhancement factors are defined as the ratio of the number of particles of a given size per unit mass of air in the sample to the number of particles of that size per unit mass of air in the ambient. Experimenters divide measured mixing ratios of the aerosol by the enhancement factor to get the ambient mixing ratio of the particles. The diffuser used in ACE-Asia differed from that used in PELTI (2000), TexAQS2000 (2000) and ITCT (2002). In this poster, the flow parameters measured in the inlet in flight are compared with those calculated from FLUENT. And enhancement factors are presented for flight conditions. The enhancement factors are found to depend upon the Stokes number of particles in the entrance to the inlet and the ratio of the mass flow rate of air removed by suction to the mass flow rate delivered as sample.
Air Quality Inside Police Drug Safes and Drug Storage Areas.
Doran, Gregory S; Deans, Ralph; De Filippis, Carlo; Kostakis, Chris; Howitt, Julia A
2018-06-01
Storage of drug-based evidence inside sealed safes may allow chemical vapors to accumulate, creating concerns of drug exposure by inhalation, or the possibility of cross-contamination of drug evidence. Air samples were taken from inside eight drug safes and one small storage room at nine city and country police stations, as well as a large centralized drug evidence storage vault, in New South Wales (NSW), Australia. Sorbent tubes containing charcoal were used to determine whether any drug residues could be detected in the air, and to identify the types of chemicals present. Carbon traps were extracted and analyzed by LC-MS-MS for a suite of 22 licit and illicit drug residues and 2 metabolites. Carbon traps and SPME fibers were also analyzed by GC-MS for general volatile organic compound (VOC) residues. No detectable drug residues, either as airborne dust or vapor, were found in the safes, the storage room or the large central repository vault. No drugs were detected in any of the 34 urine samples collected at 8 of the 10 sampling locations, while only one of the five hair samples was positive for cocaine (9 pg/mg) provided by police exhibit officers at 3 of the 10 sampling locations. VOC analysis identified a variety of solvents associated with drug manufacture, plasticisers, personal care products and volatiles associated with plants such as cannabis. The results indicate that strong chemical odours emanating from drug safes are unlikely to be drug residues due to low volatility of drugs, and are more likely VOCs associated with their manufacture or from plant growing operations. Consideration should be given to the quality of air flow in rooms in which safes are housed and the use of air filtering inside safes to reduce the likelihood of VOC accumulation, and therefore the risk of human exposure.
Workplace Respiratory Protection Factors during Asbestos Removal Operations.
Chazelet, Sandrine; Wild, Pascal; Silvente, Eric; Eypert-Blaison, Céline
2018-05-28
Numerous changes have been made to the French labour regulations in recent years relating to the prevention of risks of exposure to asbestos fibres for operators removing asbestos-containing materials. These changes refer to the method used to count fibres, the collective and personal protective devices to be used on these worksites, and the occupational exposure limit value, which was reduced to 10 f.L-1 on 2 July 2015. In this context, this study assessed the level of respiratory protection afforded by supplied-air respirators and powered air-purifying respirators by monitoring exposure for several operators on nine worksites. The levels of dustiness measured in personal samples taken outside masks showed significant evidence of potential exposure during removal of asbestos-containing plaster or sprayed asbestos, and when using abrasive blasting to treat asbestos-containing materials. For these tasks outside concentration regularly exceeds 25000 f.L-1. Measurements inside masks were generally low, under 10 f.L-1, except in some situations involving the removal of asbestos-containing plaster. This partial penetration of fibres inside masks could be due to the high loading linked to this material. The distributions of Workplace Protection Factors obtained for the two types of respiratory protective devices studied were broad, and the fifth percentile values equal to 236 and 104, respectively, for supplied-air respirators and powered air-purifying respirators. This work highlights once again the need to prioritize collective protection when seeking to prevent asbestos-related risks.
Exposure science in U.S. military operations: a review.
Martin, Nicholas J; Richards, Erin E; Kirkpatrick, Jeffrey S
2011-07-01
Since 1991, the U.S. Department of Defense has conducted deployment occupational and environmental health surveillance activities in the geographic combatant commands for major conflicts, military exercises, and humanitarian and peace-building missions. The DoD has made significant improvements in documenting and assessing deployment environmental hazards and threats since 1991, illustrated by accomplishments in Bosnia, Kosovo, and Operations Noble Eagle (following the September 11, 2001 terrorist attacks); Enduring Freedom-Afghanistan; and Iraqi Freedom (2003-2010). Sampling is now recommended as part of the DoD Exposure Assessment Method, a dynamic process that is performed during all phases of military operations: I--Predeployment, II--Mobilization, III--Conflict, and IV-Postdeployment. From 2001 to 2009, deployed personnel collected over 24,500 air, water, soil, and bulk samples during operations. These efforts have lead to the creation of an environmental health surveillance database that has been used to investigate public health issues. However, gaps exist, especially in the assessment of individual exposures during deployment.
14 CFR 119.21 - Commercial operators engaged in intrastate common carriage and direct air carriers.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Commercial operators engaged in intrastate common carriage and direct air carriers. 119.21 Section 119.21 Aeronautics and Space FEDERAL AVIATION...: CERTIFICATION AND OPERATIONS CERTIFICATION: AIR CARRIERS AND COMMERCIAL OPERATORS Applicability of Operating...
14 CFR 119.21 - Commercial operators engaged in intrastate common carriage and direct air carriers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Commercial operators engaged in intrastate common carriage and direct air carriers. 119.21 Section 119.21 Aeronautics and Space FEDERAL AVIATION...: CERTIFICATION AND OPERATIONS CERTIFICATION: AIR CARRIERS AND COMMERCIAL OPERATORS Applicability of Operating...
14 CFR 119.21 - Commercial operators engaged in intrastate common carriage and direct air carriers.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Commercial operators engaged in intrastate common carriage and direct air carriers. 119.21 Section 119.21 Aeronautics and Space FEDERAL AVIATION...: CERTIFICATION AND OPERATIONS CERTIFICATION: AIR CARRIERS AND COMMERCIAL OPERATORS Applicability of Operating...
14 CFR 119.21 - Commercial operators engaged in intrastate common carriage and direct air carriers.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Commercial operators engaged in intrastate common carriage and direct air carriers. 119.21 Section 119.21 Aeronautics and Space FEDERAL AVIATION...: CERTIFICATION AND OPERATIONS CERTIFICATION: AIR CARRIERS AND COMMERCIAL OPERATORS Applicability of Operating...
14 CFR 119.21 - Commercial operators engaged in intrastate common carriage and direct air carriers.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Commercial operators engaged in intrastate common carriage and direct air carriers. 119.21 Section 119.21 Aeronautics and Space FEDERAL AVIATION...: CERTIFICATION AND OPERATIONS CERTIFICATION: AIR CARRIERS AND COMMERCIAL OPERATORS Applicability of Operating...
49 CFR 1542.203 - Security of the air operations area (AOA).
Code of Federal Regulations, 2013 CFR
2013-10-01
...) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY AIRPORT SECURITY Operations § 1542.203 Security of the air operations area (AOA). (a) Each airport operator required to have a... 49 Transportation 9 2013-10-01 2013-10-01 false Security of the air operations area (AOA). 1542...
49 CFR 1542.203 - Security of the air operations area (AOA).
Code of Federal Regulations, 2010 CFR
2010-10-01
...) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY AIRPORT SECURITY Operations § 1542.203 Security of the air operations area (AOA). (a) Each airport operator required to have a... 49 Transportation 9 2010-10-01 2010-10-01 false Security of the air operations area (AOA). 1542...
49 CFR 1542.203 - Security of the air operations area (AOA).
Code of Federal Regulations, 2011 CFR
2011-10-01
...) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY AIRPORT SECURITY Operations § 1542.203 Security of the air operations area (AOA). (a) Each airport operator required to have a... 49 Transportation 9 2011-10-01 2011-10-01 false Security of the air operations area (AOA). 1542...
49 CFR 1542.203 - Security of the air operations area (AOA).
Code of Federal Regulations, 2012 CFR
2012-10-01
...) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY AIRPORT SECURITY Operations § 1542.203 Security of the air operations area (AOA). (a) Each airport operator required to have a... 49 Transportation 9 2012-10-01 2012-10-01 false Security of the air operations area (AOA). 1542...
49 CFR 1542.203 - Security of the air operations area (AOA).
Code of Federal Regulations, 2014 CFR
2014-10-01
...) TRANSPORTATION SECURITY ADMINISTRATION, DEPARTMENT OF HOMELAND SECURITY CIVIL AVIATION SECURITY AIRPORT SECURITY Operations § 1542.203 Security of the air operations area (AOA). (a) Each airport operator required to have a... 49 Transportation 9 2014-10-01 2014-10-01 false Security of the air operations area (AOA). 1542...
NASA Technical Reports Server (NTRS)
Waco, D. E.
1979-01-01
The results of 46 clear air turbulence (CAT) probing missions conducted with an extensively instrumented B-57B aircraft are summarized from a meteorological viewpoint in a two-volume technical memorandum. The missions were part of the NASA Langley Research Center's MAT (Measurement of Atmospheric Turbulence) program, which was conducted between March 1974, and September 1975, at altitudes ranging up to 15 km. Turbulence samples were obtained under diverse conditions including mountain waves, jet streams, upper level fronts and troughs, and low altitude mechanical and thermal turbulence. CAT was encountered on 20 flights comprising 77 data runs. In all, approximately 4335 km were flown in light turbulence, 1415 km in moderate turbulence, and 255 km in severe turbulence during the program.
14 CFR 375.50 - Transit flights; scheduled international air service operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... WITHIN THE UNITED STATES Transit Flights § 375.50 Transit flights; scheduled international air service operations. (a) Requirement of notice. Scheduled international air services proposed to be operated pursuant to the International Air Services Transit Agreement in transit across the United States may not be...
14 CFR 375.50 - Transit flights; scheduled international air service operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... WITHIN THE UNITED STATES Transit Flights § 375.50 Transit flights; scheduled international air service operations. (a) Requirement of notice. Scheduled international air services proposed to be operated pursuant to the International Air Services Transit Agreement in transit across the United States may not be...
14 CFR 375.50 - Transit flights; scheduled international air service operations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... WITHIN THE UNITED STATES Transit Flights § 375.50 Transit flights; scheduled international air service operations. (a) Requirement of notice. Scheduled international air services proposed to be operated pursuant to the International Air Services Transit Agreement in transit across the United States may not be...
14 CFR 375.50 - Transit flights; scheduled international air service operations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... WITHIN THE UNITED STATES Transit Flights § 375.50 Transit flights; scheduled international air service operations. (a) Requirement of notice. Scheduled international air services proposed to be operated pursuant to the International Air Services Transit Agreement in transit across the United States may not be...
14 CFR 375.50 - Transit flights; scheduled international air service operations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... WITHIN THE UNITED STATES Transit Flights § 375.50 Transit flights; scheduled international air service operations. (a) Requirement of notice. Scheduled international air services proposed to be operated pursuant to the International Air Services Transit Agreement in transit across the United States may not be...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-01
...) of the Aircraft Certification Service (AIR) Process for the Sequencing of Certification and... on the Aircraft Certification Service (AIR) standard operating procedure (SOP) describing the process... comments on the SOP : AIR-100-001; Standard Operating Procedure--Aircraft Certification Service Project...
14 CFR 294.31 - Use of business name.
Code of Federal Regulations, 2011 CFR
2011-01-01
... REGULATIONS CANADIAN CHARTER AIR TAXI OPERATORS General Rules for Registrants § 294.31 Use of business name. (a) A Canadian charter air taxi operator, in holding out charter air service to the public and... this part. The Department may require a Canadian charter air taxi operator to change such names where...
Alsved, M; Civilis, A; Ekolind, P; Tammelin, A; Andersson, A Erichsen; Jakobsson, J; Svensson, T; Ramstorp, M; Sadrizadeh, S; Larsson, P-A; Bohgard, M; Šantl-Temkiv, T; Löndahl, J
2018-02-01
To evaluate three types of ventilation systems for operating rooms with respect to air cleanliness [in colony-forming units (cfu/m 3 )], energy consumption and comfort of working environment (noise and draught) as reported by surgical team members. Two commonly used ventilation systems, vertical laminar airflow (LAF) and turbulent mixed airflow (TMA), were compared with a newly developed ventilation technique, temperature-controlled airflow (T c AF). The cfu concentrations were measured at three locations in an operating room during 45 orthopaedic procedures: close to the wound (<40cm), at the instrument table and peripherally in the room. The operating team evaluated the comfort of the working environment by answering a questionnaire. LAF and T c AF, but not TMA, resulted in less than 10cfu/m 3 at all measurement locations in the room during surgery. Median values of cfu/m 3 close to the wound (250 samples) were 0 for LAF, 1 for T c AF and 10 for TMA. Peripherally in the room, the cfu concentrations were lowest for T c AF. The cfu concentrations did not scale proportionally with airflow rates. Compared with LAF, the power consumption of T c AF was 28% lower and there was significantly less disturbance from noise and draught. T c AF and LAF remove bacteria more efficiently from the air than TMA, especially close to the wound and at the instrument table. Like LAF, the new T c AF ventilation system maintained very low levels of cfu in the air, but T c AF used substantially less energy and provided a more comfortable working environment than LAF. This enables energy savings with preserved air quality. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Mass Airflow Cabinet for Control of Airborne Infection of Laboratory Rodents
McGarrity, Gerard J.; Coriell, Lewis L.
1973-01-01
A mass airflow cabinet for handling and housing of laboratory rodents has been developed and tested. The unit consists of a high-efficiency particulate air filter and uniform distribution of air at a vertical velocity of 19 cm per s. Animals are maintained without bedding in mesh-bottomed cages that rest on rollers for rotation inside the cabinet. There is an air barrier of 90 cm per s separating the cabinet air from room air. Sampling for airborne bacteria yielded an average of 0.03 colony-forming units (CFU) per ft3 of air inside the cabinet, whereas 28.8 CFU per ft3 was simultaneously detected outside the cabinet during housekeeping, a reduction of almost three logs. The efficiency of the air barrier was tested by aerosolization of T3 phage. When phage was aerosolized 5 cm outside the cabinet, no phage could be detected 5 cm inside when the fans were operating; with the fans off an average of 1.6 × 104 plaque-forming units (PFU) per ft3 was detected in six tests. Aerosolization of phage inside the cabinet yielded an average of 9 × 10 PFU per ft3 outside; an average of 4.1 × 106 PFU per ft3 were detected with the fans not in operation, a reduction of more than four logs. In-use studies on effectiveness showed that the cabinet significantly reduced the incidence of mice originally titer-free to Reo-3 virus. Hemagglutination inhibition antibodies to Reo-3 were detected in 9/22 (42%) mice housed in a conventionally ventilated animal laboratory while no seroconversion was detected in any of 22 mice housed in the mass air flow cabinet in the same laboratory. Images PMID:4355261
Mass airflow cabinet for control of airborne infection of laboratory rodents.
McGarrity, G J; Coriell, L L
1973-08-01
A mass airflow cabinet for handling and housing of laboratory rodents has been developed and tested. The unit consists of a high-efficiency particulate air filter and uniform distribution of air at a vertical velocity of 19 cm per s. Animals are maintained without bedding in mesh-bottomed cages that rest on rollers for rotation inside the cabinet. There is an air barrier of 90 cm per s separating the cabinet air from room air. Sampling for airborne bacteria yielded an average of 0.03 colony-forming units (CFU) per ft(3) of air inside the cabinet, whereas 28.8 CFU per ft(3) was simultaneously detected outside the cabinet during housekeeping, a reduction of almost three logs. The efficiency of the air barrier was tested by aerosolization of T3 phage. When phage was aerosolized 5 cm outside the cabinet, no phage could be detected 5 cm inside when the fans were operating; with the fans off an average of 1.6 x 10(4) plaque-forming units (PFU) per ft(3) was detected in six tests. Aerosolization of phage inside the cabinet yielded an average of 9 x 10 PFU per ft(3) outside; an average of 4.1 x 10(6) PFU per ft(3) were detected with the fans not in operation, a reduction of more than four logs. In-use studies on effectiveness showed that the cabinet significantly reduced the incidence of mice originally titer-free to Reo-3 virus. Hemagglutination inhibition antibodies to Reo-3 were detected in 9/22 (42%) mice housed in a conventionally ventilated animal laboratory while no seroconversion was detected in any of 22 mice housed in the mass air flow cabinet in the same laboratory.
Operational manual for two-dimensional transonic code TSFOIL
NASA Technical Reports Server (NTRS)
Stahara, S. S.
1978-01-01
This code solves the two-dimensional, transonic, small-disturbance equations for flow past lifting airfoils in both free air and various wind-tunnel environments by using a variant of the finite-difference method. A description of the theoretical and numerical basis of the code is provided, together with complete operating instructions and sample cases for the general user. In addition, a programmer's manual is also presented to assist the user interested in modifying the code. Included in the programmer's manual are a dictionary of subroutine variables in common and a detailed description of each subroutine.
NASA Technical Reports Server (NTRS)
Tieleman, H. W.; Derrington, D. B., Jr.
1977-01-01
Turbulent flow, resembling an on-shore flow from the ocean crossing the beach at an oblique angle, is investigated. Measurements of this flow have been taken at high sample rates and include measurements at various heights, high enough to describe the portion of the mean wind and temperature profiles and fluxes that are of interest for the solution of practical engineering problems. These problems could include air pollution (fumigation and plume trapping), operation of low flying aircraft, crop-spraying and crop-dusting operations.
Hydrogen as an Auxiliary Fuel in Compression-Ignition Engines
NASA Technical Reports Server (NTRS)
Gerrish, Harold C; Foster, H
1936-01-01
An investigation was made to determine whether a sufficient amount of hydrogen could be efficiently burned in a compression-ignition engine to compensate for the increase of lift of an airship due to the consumption of the fuel oil. The performance of a single-cylinder four-stroke-cycle compression-ignition engine operating on fuel oil alone was compared with its performance when various quantities of hydrogen were inducted with the inlet air. Engine-performance data, indicator cards, and exhaust-gas samples were obtained for each change in engine-operating conditions.
A flow boiling microchannel thermosyphon for fuel cell thermal management
NASA Astrophysics Data System (ADS)
Garrity, Patrick Thomas
To provide a high power density thermal management system for proton exchange membrane (PEM) fuel cell applications, a passively driven thermal management system was assembled to operate in a closed loop two-phase thermosyphon. The system has two major components; a microchannel evaporator plate and a condenser. The microchannel evaporator plate was fabricated with 56 square channels that have a 1 mm x 1 mm cross section and are 115 mm long. Experiments were conducted with a liquid cooled condenser with heat flux as the control variable. Measurements of mass flow rate, temperature field, and pressure drop have been made for the thermosyphon loop. A model is developed to predict the system characteristics such as the temperature and pressure fields, flow rate, flow regime, heat transfer coefficient, and maximum heat flux. When the system is subjected to a heat load that exceeds the maximum heat flux, an unstable flow regime is observed that causes flow reversal and eventual dryout near the evaporator plate wall. This undesirable phenomenon is modeled based on a quasi-steady state assumption, and the model is capable of predicting the heat flux at the onset of instability for quasi-steady two-phase flow. Another focus of this work is the performance of the condenser portion of the loop, which will be air cooled in practice. The aim is to reduce air side thermal resistance and increase the condenser performance, which is accomplished with extended surfaces. A testing facility is assembled to observe the air side heat transfer performance of three aluminum foam samples and three modified carbon foam samples, used as extended surfaces. The aluminum foam samples have a bulk density of 216 kilograms per cubic meter with pore sizes of 0.5, 1, and 2 mm. The modified carbon foam samples have bulk densities of 284, 317, and 400 kilograms per cubic meter and machined flow passages of 3.2 mm. in diameter. Each sample is observed under forced convection with air velocity as the control variable. Thermocouples and pressure taps are distributed axially along the test section and measurements of pressure and temperature are recorded for air velocities ranging from 1-6 meters per second. Using the Darcy-Forcheimer equation, the porosity is determined for each sample. The volumetric heat transfer coefficient is extracted by means of solving the coupled energy equations of both the solid and fluid respectively. Nusselt number is correlated with Reynolds number. The optimal foam configuration is explored based on a Coefficient of Performance, (COP), Compactness Factor (CF) and Power Density (PD). The COP is the ratio of total heat removed to electrical heat consumption of the blower, CF is the total heat removed per unit volume, and PD is the total heat removed per unit mass. These performance parameters are computed for a hypothetical heat exchanger using each foam sample at various fluid velocities. They are also compared against those for the hypothetical heat exchanger fitted with conventional louvered fins. Given a proper weighting function based on the importance of CF, COP, and PD in the condenser design, an optimal configuration for an air cooled condenser can be obtained for various operating conditions.
NASA Astrophysics Data System (ADS)
Staymates, Matthew E.; Maccrehan, William A.; Staymates, Jessica L.; Kunz, Roderick R.; Mendum, Thomas; Ong, Ta-Hsuan; Geurtsen, Geoffrey; Gillen, Greg J.; Craven, Brent A.
2016-12-01
Unlike current chemical trace detection technology, dogs actively sniff to acquire an odor sample. Flow visualization experiments with an anatomically-similar 3D printed dog’s nose revealed the external aerodynamics during canine sniffing, where ventral-laterally expired air jets entrain odorant-laden air toward the nose, thereby extending the “aerodynamic reach” for inspiration of otherwise inaccessible odors. Chemical sampling and detection experiments quantified two modes of operation with the artificial nose-active sniffing and continuous inspiration-and demonstrated an increase in odorant detection by a factor of up to 18 for active sniffing. A 16-fold improvement in detection was demonstrated with a commercially-available explosives detector by applying this bio-inspired design principle and making the device “sniff” like a dog. These lessons learned from the dog may benefit the next-generation of vapor samplers for explosives, narcotics, pathogens, or even cancer, and could inform future bio-inspired designs for optimized sampling of odor plumes.
Staymates, Matthew E.; MacCrehan, William A.; Staymates, Jessica L.; Kunz, Roderick R.; Mendum, Thomas; Ong, Ta-Hsuan; Geurtsen, Geoffrey; Gillen, Greg J.; Craven, Brent A.
2016-01-01
Unlike current chemical trace detection technology, dogs actively sniff to acquire an odor sample. Flow visualization experiments with an anatomically-similar 3D printed dog’s nose revealed the external aerodynamics during canine sniffing, where ventral-laterally expired air jets entrain odorant-laden air toward the nose, thereby extending the “aerodynamic reach” for inspiration of otherwise inaccessible odors. Chemical sampling and detection experiments quantified two modes of operation with the artificial nose-active sniffing and continuous inspiration-and demonstrated an increase in odorant detection by a factor of up to 18 for active sniffing. A 16-fold improvement in detection was demonstrated with a commercially-available explosives detector by applying this bio-inspired design principle and making the device “sniff” like a dog. These lessons learned from the dog may benefit the next-generation of vapor samplers for explosives, narcotics, pathogens, or even cancer, and could inform future bio-inspired designs for optimized sampling of odor plumes. PMID:27906156
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCoy, R.P.
1992-08-01
A wastewater characterization survey was conducted at Edwards Air Force Base from 17-28 February 1992 by personnel from the Water Quality Function of Armstrong Laboratory. Extensive sampling of the treatment plant influent wastewater and sludge beds was performed as well as sampling at nine other sites in the base cantonment area. Some sampling of an Imhoff tank on North Base, five evaporation ponds and the lakebed was also conducted. Low levels of organic contamination were found in the influent and industrial sites downstream of Site 7. Site 7 is a manhole located in an identified Installation Restoration Program (IRP) site.more » Corrective actions were recommended to prevent organic soil contaminants from intruding into this site prior to the operation of a planned tertiary treatment plant. Organic and inorganic contaminants discharged at other industrial sites were found to be in low concentrations and indicated that good shop practices were followed in minimizing contamination of the wastewater with industrial chemicals.« less
Water quality monitoring of Sweetwater and Loveland reservoirs--Phase one results 1998-1999
Majewski, Michael S.; Sidhu, Jagdeep S.; Mendez, Gregory O.
2002-01-01
In 1998, the U.S. Geological Survey began a study to assess the overall health of the watershed feeding the Sweetwater Reservoir in southern San Diego County, California. The study focussed on monitoring for organic chemical contamination and the effects of construction and operation of State Route 125 on water quality. Three environmental compartments (air, water, and bed sediments) are being sampled regularly for chemical contaminants, including volatile organic compounds, polynuclear aromatic hydrocarbons, polychlorinated biphenyls, pesticides, and major and trace elements. The study is divided into two phases. Phase I sampling is designed to establish baseline conditions for target compounds in terms of detection frequency and concentration in air, water, and bed sediments. Phase II sampling will continue at the established monitoring sites during and after construction of State Route 125 to assess chemical impact on water quality in the reservoir resulting from land-use changes and development in the watershed. This report describes the study design, the sampling and analytical methods, and presents the data results for the first year of the study, September 1998 to September 1999.
Zhang, Weihua; Bean, Marc; Benotto, Mike; Cheung, Jeff; Ungar, Kurt; Ahier, Brian
2011-12-01
A high volume aerosol sampler ("Grey Owl") has been designed and developed at the Radiation Protection Bureau, Health Canada. Its design guidance is based on the need for a low operational cost and reliable sampler to provide daily aerosol monitoring samples that can be used as reference samples for radiological studies. It has been developed to provide a constant air flow rate at low pressure drops (∼3 kPa for a day sampling) with variations of less than ±1% of the full scale flow rate. Its energy consumption is only about 1.5 kW for a filter sampling over 22,000 standard cubic meter of air. It has been demonstrated in this Fukushima nuclear accident related aerosol radioactivity monitoring study at Sidney station, B.C. that the sampler is robust and reliable. The results provided by the new monitoring system have been used to support decision-making in Canada during an emergency response. Copyright © 2011 Elsevier Ltd. All rights reserved.
Bohlin, P; Audy, O; Škrdlíková, L; Kukučka, P; Přibylová, P; Prokeš, R; Vojta, Š; Klánová, J
2014-03-01
The most commonly used passive air sampler (PAS) (i.e. polyurethane foam (PUF) disk) is cheap, versatile, and capable of accumulating compounds present both in gas and particle phases. Its performance for particle associated compounds is however disputable. In this study, twelve sets of triplicate PUF-PAS were deployed outdoors for exposure periods of 1-12 weeks together with continuously operated active samplers, to characterize sampling efficiency and derive sampling rates (RS) for compounds belonging to 7 SVOC classes (including particle associated compounds). PUF-PAS efficiently and consistently sampled polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), polycyclic aromatic hydrocarbons (PAHs), and eight novel brominated flame retardant (nBFR) compounds. Low accuracy and lack of sensitivity was observed for most polychlorinated dibenzo-p-dioxins/furans PCDD/Fs and polybrominated diphenyl ethers (PBDEs) (under the conditions of this study), with the exception of some congeners which may be used as qualitative markers for their respective classes. Application of compound specific RS was found crucial for all compounds except PCBs. Sampling efficiency of the particle associated compounds was often low.
14 CFR 298.35 - Limitations on carriage of mail.
Code of Federal Regulations, 2011 CFR
2011-01-01
... PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Limitations and Conditions on Exemptions and Operations § 298.35 Limitations on carriage of mail. An air taxi operator or...
14 CFR 298.35 - Limitations on carriage of mail.
Code of Federal Regulations, 2010 CFR
2010-01-01
... PROCEEDINGS) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Limitations and Conditions on Exemptions and Operations § 298.35 Limitations on carriage of mail. An air taxi operator or...
NASA Technical Reports Server (NTRS)
Rogers, Ralph V.
1992-01-01
This research project addresses the need to provide an efficient and safe mechanism to investigate the effects and requirements of the tiltrotor aircraft's commercial operations on air transportation infrastructures, particularly air traffic control. The mechanism of choice is computer simulation. Unfortunately, the fundamental paradigms of the current air traffic control simulation models do not directly support the broad range of operational options and environments necessary to study tiltrotor operations. Modification of current air traffic simulation models to meet these requirements does not appear viable given the range and complexity of issues needing resolution. As a result, the investigation of systemic, infrastructure issues surrounding the effects of tiltrotor commercial operations requires new approaches to simulation modeling. These models should be based on perspectives and ideas closer to those associated with tiltrotor air traffic operations.
Freitas, Ângela M; Portuguez, Mirna Wetters; Russomano, Thaís; Freitas, Marcos de; Silvello, Silvio Luis da Silva; Costa, Jaderson Costa da
2017-10-01
To evaluate symptoms of stress and excessive daytime sleepiness (EDS) in air traffic control (ATC) officers in Brazil. Fifty-two ATC officers participated, based at three air traffic control units, identified as A, B and C. Stress symptoms were assessed using the Lipp Inventory of Stress Symptoms for Adults, and EDS by the Epworth Sleepiness Scale. The sample mean age was 37 years, 76.9% of whom were male. Excessive daytime sleepiness was identified in 25% of the ATC officers, with 84.6% of these based at air traffic control unit A, which has greater air traffic flow, operating a 24-hour alternating work shift schedule. A total of 16% of the ATC officers had stress symptoms, and of these, 62% showed a predominance of physical symptoms. The high percentage of ATC officers with EDS identified in group A may be related to chronodisruption due to night work and alternating shifts.
14 CFR 294.32 - Security arrangements for operating Public Charters.
Code of Federal Regulations, 2010 CFR
2010-01-01
... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS CANADIAN CHARTER AIR TAXI OPERATORS General Rules for Registrants § 294.32 Security arrangements for operating Public Charters. When a Canadian charter air taxi... taxi operator shall meet the bonding or escrow requirements applicable to foreign air carriers as set...
14 CFR 294.32 - Security arrangements for operating Public Charters.
Code of Federal Regulations, 2011 CFR
2011-01-01
... (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS CANADIAN CHARTER AIR TAXI OPERATORS General Rules for Registrants § 294.32 Security arrangements for operating Public Charters. When a Canadian charter air taxi... taxi operator shall meet the bonding or escrow requirements applicable to foreign air carriers as set...
14 CFR 298.11 - Exemption authority.
Code of Federal Regulations, 2011 CFR
2011-01-01
... REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Exemptions § 298.11 Exemption authority. Air taxi operators and commuter air carriers are hereby relieved from the following provisions of... imposed herein, and to the extent necessary to permit them to conduct air taxi or commuter air carrier...
14 CFR 298.11 - Exemption authority.
Code of Federal Regulations, 2010 CFR
2010-01-01
... REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Exemptions § 298.11 Exemption authority. Air taxi operators and commuter air carriers are hereby relieved from the following provisions of... imposed herein, and to the extent necessary to permit them to conduct air taxi or commuter air carrier...
14 CFR 380.11 - Payment to direct air carrier(s).
Code of Federal Regulations, 2010 CFR
2010-01-01
... carrier(s). Except for air taxi operators and commuter air carriers (which are governed by 14 CFR 298.38) and Canadian charter air taxi operators (which are governed by 14 CFR 294.32), the direct air carrier...
14 CFR 380.11 - Payment to direct air carrier(s).
Code of Federal Regulations, 2011 CFR
2011-01-01
... carrier(s). Except for air taxi operators and commuter air carriers (which are governed by 14 CFR 298.38) and Canadian charter air taxi operators (which are governed by 14 CFR 294.32), the direct air carrier...
Bischoff, W E; Kindermann, A; Sander, U; Sander, J
1995-10-01
In eleven centrally ventilated operating theatres the concentration of particles and airborne germs in wound vicinity was measured on three workdays. Five theatres were equipped with air supply ceilings with supporting flow outlets (supporting flow ceilings), five with laminar air flow ceilings and one with an air supply ceiling, a body exhaust system and a partition wall between the anesthetic and operating areas. Under routine conditions the air supply of the laminar air flow ceiling with its lower turbulence shielded the operating field from the largely staff-related air contamination in the rest of the theatre better than in the case of the supporting flow ceilings. Particles and airborne germs were removed from the endangered wound area faster. A spatial separation between the anesthetic and the operating areas as well as a body exhaust system lead to a considerable reduction of the contamination. Two theatres were conspicuous by reason of their considerably raised values due to defective control engineering and the wrongly positioning of the operating table. From the point of view of ventilation technique the laminar air flow ceilings with lower turbulence are superior to air supply ceilings with supporting flow outlets in the working day of an operating theatre. In order to minimize the influence of the staff, which up till now has been neglected in testing specifications, constructional possibilities such as the size of ceiling, the partitioning off of operating and anaesthetic areas and the positioning of the operating table in relation to the incoming air should be coordinated rationally. Taking measurements regularly during operations can provide the impulse for considerable improvements in both operational and planning phases.
Use of Electronic Hand-held Devices for Collection of Savannah River Site Environmental Data - 13329
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marberry, Hugh; Moore, Winston
2013-07-01
Savannah River Nuclear Solutions has begun using Xplore Tablet PC's to collect data in the field for soil samples, groundwater samples, air samples and round sheets at the Savannah River Site (SRS). EPA guidelines for groundwater sampling are incorporated into the application to ensure the sample technician follows the proper protocol. The sample technician is guided through the process for sampling and round sheet data collection by a series of menus and input boxes. Field measurements and well stabilization information are entered into the tablet for uploading into Environmental Restoration Data Management System (ERDMS). The process helps to eliminate inputmore » errors and provides data integrity. A soil sample technician has the ability to collect information about location of sample, field parameter, describe the soil sample, print bottle labels, and print chain of custody for the sample that they have collected. An air sample technician has the ability to provide flow, pressure, hours of operation, print bottle labels and chain of custody for samples they collect. Round sheets are collected using the information provided in the various procedures. The data are collected and uploaded into ERDMS. The equipment used is weather proof and hardened for the field use. Global Positioning System (GPS) capabilities are integrated into the applications to provide the location where samples were collected and to help sample technicians locate wells that are not visited often. (authors)« less
14 CFR 253.8 - Qualifications to notice requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... without penalty. (b) An air taxi operator (including a commuter air carrier) not operating under subpart I..., such an air taxi operator may not claim the benefit as against the passenger of, and the passenger...
14 CFR 253.8 - Qualifications to notice requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
... without penalty. (b) An air taxi operator (including a commuter air carrier) not operating under subpart I..., such an air taxi operator may not claim the benefit as against the passenger of, and the passenger...
The purpose of this SOP is to describe the general procedures to be followed for cleaning glassware used in preparing and analyzing soil, house dust, air filter, surface wipe, or dermal wash samples for inorganic metals. This procedure was followed to ensure consistent data retr...
The purpose of this SOP is to describe procedures for preparing calibration curve solutions used for gas chromatography/mass spectrometry (GC/MS) analysis of chlorpyrifos, diazinon, malathion, DDT, DDE, DDD, a-chlordane, and g-chlordane in dust, soil, air, and handwipe sample ext...
Potential impact of air quality restrictions on logging residue burning
Owen P. Cramer; James N. Westwood
1970-01-01
The number of potential burning days and the potential burn acreage under smoke control restrictions were estimated for hypothetical forest areas on both sides of a pollution prone area, the Willamette Valley in western Oregon. On the basis of a sample of 2 dry years, the greatest impact on burning operations applied to low elevation forests west of the Valley. The...
Defense.gov - Dignity, Honor, Respect - For the Fallen
combat operation passes through Dover Air Force Base, Del. The responsibility, and honor, of preparing Operations Center. Stories Dignified Transfer Pays Tribute to Fallen DOVER AIR FORCE BASE, Del., March 12 vehicle to the Air Force Mortuary Affairs Operations Center at Dover Air Force Base, Del. Story Center
21 CFR 878.5070 - Air-handling apparatus for a surgical operating room.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Air-handling apparatus for a surgical operating room. 878.5070 Section 878.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....5070 Air-handling apparatus for a surgical operating room. (a) Identification. Air-handling apparatus...
21 CFR 878.5070 - Air-handling apparatus for a surgical operating room.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Air-handling apparatus for a surgical operating room. 878.5070 Section 878.5070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND....5070 Air-handling apparatus for a surgical operating room. (a) Identification. Air-handling apparatus...
14 CFR 298.33 - Security requirements.
Code of Federal Regulations, 2011 CFR
2011-01-01
...) ECONOMIC REGULATIONS EXEMPTIONS FOR AIR TAXI AND COMMUTER AIR CARRIER OPERATIONS Limitations and Conditions..., an air taxi operator or a commuter air carrier is required to adhere to all security requirements...
Comparison of two confocal micro-XRF spectrometers with different design aspects
Smolek, S; Nakazawa, T; Tabe, A; Nakano, K; Tsuji, K; Streli, C; Wobrauschek, P
2014-01-01
Two different confocal micro X-ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500 nm in thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard reference material glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface. © 2013 The Authors. X-Ray Spectrometry published by John Wiley & Sons, Ltd. PMID:26430286
Comparison of two confocal micro-XRF spectrometers with different design aspects.
Smolek, S; Nakazawa, T; Tabe, A; Nakano, K; Tsuji, K; Streli, C; Wobrauschek, P
2014-03-01
Two different confocal micro X-ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500 nm in thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard reference material glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface. © 2013 The Authors. X-Ray Spectrometry published by John Wiley & Sons, Ltd.
Code of Federal Regulations, 2011 CFR
2011-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
Code of Federal Regulations, 2010 CFR
2010-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
Code of Federal Regulations, 2012 CFR
2012-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
Code of Federal Regulations, 2013 CFR
2013-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
Code of Federal Regulations, 2014 CFR
2014-07-01
... covered electric furnaces and other smelting operations with wet air pollution control devices subcategory... Smelting Operations With Wet Air Pollution Control Devices Subcategory § 424.20 Applicability; description of the covered electric furnaces and other smelting operations with wet air pollution control devices...
2008-06-13
Mobility Division AMLO Air Mobility Liaison Officer AMR Air Movement Request AO Area of Operations AOC Air and Space Operations Center BAE...those forces and by doctrine can only advise the AOC Director. Adding to this confused chain of command, the Air Mobility Liaison Officers ( AMLO ...there is not a commander of airlift forces and the AMLO typically answers to Air Mobility Command’s (AMC) 18th Air Force Commander when deployed to
Swarthout, Robert F; Russo, Rachel S; Zhou, Yong; Miller, Brandon M; Mitchell, Brittney; Horsman, Emily; Lipsky, Eric; McCabe, David C; Baum, Ellen; Sive, Barkley C
2015-03-03
The Marcellus Shale is the largest natural gas deposit in the U.S. and rapid development of this resource has raised concerns about regional air pollution. A field campaign was conducted in the southwestern Pennsylvania region of the Marcellus Shale to investigate the impact of unconventional natural gas (UNG) production operations on regional air quality. Whole air samples were collected throughout an 8050 km(2) grid surrounding Pittsburgh and analyzed for methane, carbon dioxide, and C1-C10 volatile organic compounds (VOCs). Elevated mixing ratios of methane and C2-C8 alkanes were observed in areas with the highest density of UNG wells. Source apportionment was used to identify characteristic emission ratios for UNG sources, and results indicated that UNG emissions were responsible for the majority of mixing ratios of C2-C8 alkanes, but accounted for a small proportion of alkene and aromatic compounds. The VOC emissions from UNG operations accounted for 17 ± 19% of the regional kinetic hydroxyl radical reactivity of nonbiogenic VOCs suggesting that natural gas emissions may affect compliance with federal ozone standards. A first approximation of methane emissions from the study area of 10.0 ± 5.2 kg s(-1) provides a baseline for determining the efficacy of regulatory emission control efforts.
Octafluoropropane Concentration Dynamics on Board the International Space Station
NASA Technical Reports Server (NTRS)
Perry, J. L.
2003-01-01
Since activating the International Space Station s (IS9 Service Module in November 2000, archival air quality samples have shown highly variable concentrations of octafluoropropane in the cabin. This variability has been directly linked to leakage from air conditioning systems on board the Service Module, Zvezda. While octafluoro- propane is not highly toxic, it presents a significant chal- lenge to the trace contaminant control systems. A discussion of octafluoropropane concentration dynamics is presented and the ability of on board trace contami- nant control systems to effectively remove octafluoropro- pane from the cabin atmosphere is assessed. Consideration is given to operational and logistics issues that may arise from octafluoropropane and other halo- carbon challenges to the contamination control systems as well as the potential for effecting cabin air quality.
Operational experience of continuous air monitoring of smoke for ²³⁹Pu during a wildfire.
Whicker, Jeffrey J; Baltz, David; Eisele, William F; Hart, Orval F; McNaughton, Michael W; Green, Andrew A
2012-08-01
Smoke from a wildfire in northern New Mexico that moved along the border of the Los Alamos National Laboratory (LANL) was monitored for ²³⁹Pu in the event that the fire might cross into LANL property containing locations with low, but greater than background, levels of ²³⁹Pu and other alpha-emitting radionuclides. Three Environmental Continuous Air Monitors (ECAMs) in operation at LANL at the time of the fire provided near real-time measurements of the ²³⁹Pu in the smoke. Sampling data from routine measurements of PM-10 and PM-2.5 concentrations in the city of Los Alamos showed that smoke in the air rose during the fire to several hundred μg m⁻³, which produced limited visibility (several hundred meters) and resulted in poor air quality alerts for about a week-long period. Previous studies have shown that airborne dust can significantly impair continuous air monitors, so the purpose of this study was to assess the performance of the ECAMs under smoky conditions, which is important for many emergency response scenarios. Additionally, ECAMs are not required to be tested in smoke by ANSI standards, so there is little to no published data on performance of any ECAM while sampling smoke. Results show that the deployed ECAMs had reduced flow as the filter clogged with fine particles, but the goodness-of-fit parameter of the peak shape fitting algorithms and the minimum detectable concentration and dose were not impacted until the flow was reduced by more than about 20%, and even then they were within tolerable limits. Overall, ECAM performance was not impacted during the fire even under heavy smoke conditions and fluctuating radon levels, though changing the filters to limit any reductions in flow to less than 20% would maintain optimal ECAM performance.