Science.gov

Sample records for operational diagnostics methods

  1. Development of wide area environment accelerator operation and diagnostics method

    NASA Astrophysics Data System (ADS)

    Uchiyama, Akito; Furukawa, Kazuro

    2015-08-01

    Remote operation and diagnostic systems for particle accelerators have been developed for beam operation and maintenance in various situations. Even though fully remote experiments are not necessary, the remote diagnosis and maintenance of the accelerator is required. Considering remote-operation operator interfaces (OPIs), the use of standard protocols such as the hypertext transfer protocol (HTTP) is advantageous, because system-dependent protocols are unnecessary between the remote client and the on-site server. Here, we have developed a client system based on WebSocket, which is a new protocol provided by the Internet Engineering Task Force for Web-based systems, as a next-generation Web-based OPI using the Experimental Physics and Industrial Control System Channel Access protocol. As a result of this implementation, WebSocket-based client systems have become available for remote operation. Also, as regards practical application, the remote operation of an accelerator via a wide area network (WAN) faces a number of challenges, e.g., the accelerator has both experimental device and radiation generator characteristics. Any error in remote control system operation could result in an immediate breakdown. Therefore, we propose the implementation of an operator intervention system for remote accelerator diagnostics and support that can obviate any differences between the local control room and remote locations. Here, remote-operation Web-based OPIs, which resolve security issues, are developed.

  2. DIAGNOSTIC METHODS IN AYURVEDA

    PubMed Central

    Thakar, V. J.

    1982-01-01

    This is an analytical study of the Diagnostic methods Prescribes in Ayurveda. As in the case of disease and treatments the concept of diagnosis also is unique in Ayurveda. It goes to the Nidana of Doshicimbalance by studying the physical, physiological, psychic and behavoural aspects of the patient. The paper gives an insight into the various diagnostic methods enunciated in Sastras which turns out to be a fore-runner of any of modern diagnostic methods. PMID:22556480

  3. The value of immunoscintigraphy for the operative retreatment of colorectal cancer. Limitations of a new diagnostic method

    SciTech Connect

    Hoelting, T.S.; Schlag, P.; Steinbaecher, M.K.; Kretzschmar, U.; Georgi, P.; Herfarth, C. )

    1989-08-15

    In 42 patients with suspected recurrent colorectal cancer, results of conventional diagnostic methods were compared with those of immunoscintigraphy. In 69% of all cases, the intraoperative findings of a second-look operation served for validation, whereas in 31% close follow-up was used. Recurrent tumors were successfully localized in 83% of patients by conventional methods, whereas immunoscintigraphy was expressive in 57% of cases. Immunoscintigraphy was disappointing especially because of its low sensitivity (23%) and low predictive value (positive, 33%; negative, 37%) with regard to successful diagnosis of extrahepatic tumors compared with the results of conventional methods (77% sensitivity; positive, 94%; negative, 79%). The rate of false-positive results was relatively high with immunoscintigraphy (n = 12), 83% of which were related to extrahepatic recurrent tumors. The value of immunoscintigraphy using an immunococktail of 131-I-labeled F(ab')2 fragments of monoclonal antibodies against CEA, with Ca 19-9 as an additional diagnostic tool for early detection of recurrent colorectal cancer, must therefore be viewed critically.

  4. First Wall and Operational Diagnostics

    SciTech Connect

    Lasnier, C; Allen, S; Boedo, J; Groth, M; Brooks, N; McLean, A; LaBombard, B; Sharpe, J; Skinner, C; Whyte, D; Rudakov, D; West, W; Wong, C

    2006-06-19

    In this chapter we review numerous diagnostics capable of measurements at or near the first wall, many of which contribute information useful for safe operation of a tokamak. There are sections discussing infrared cameras, visible and VUV cameras, pressure gauges and RGAs, Langmuir probes, thermocouples, and erosion and deposition measurements by insertable probes and quartz microbalance. Also discussed are dust measurements by electrostatic detectors, laser scattering, visible and IR cameras, and manual collection of samples after machine opening. In each case the diagnostic is discussed with a view toward application to a burning plasma machine such as ITER.

  5. Advanced diagnostic methods in avionics

    NASA Astrophysics Data System (ADS)

    Popyack, Leonard Joseph, Jr.

    Advanced diagnostic systems facilitate further enhancement of reliability and safety of modern aircraft. Unlike classical reliability analyses, addressing specific classes of systems or devices, this research is aimed at the development of methods for assessment of the individual reliability characteristics of particular system components subjected to their unique histories of operational conditions and exposure to adverse environmental factors. Individual reliability characteristics are crucial for the implementation of the most efficient maintenance practice of flight-critical system components, known as "condition-based maintenance." The dissertation presents hardware and software aspects of a computer-based system, Time-Stress Monitoring Device, developed to record, store, and analyze raw data characterizing operational and environmental conditions and performance of electro-mechanical flight control system components and aircraft electronics (avionics). Availability of this data facilitates formulation and solution of such diagnostic problems as estimation of the probability of failure and life expectancy of particular components, failure detection, identification, and prediction. Statistical aspects of system diagnostics are considered. Particular diagnostic procedures utilizing cluster analysis, Bayes' technique, and regression analysis are formulated. Laboratory and simulation experiment that verify the obtained results are provided.

  6. Myasthenia Gravis: Tests and Diagnostic Methods

    MedlinePlus

    ... Affiliations Foundation Focus Newsletter E-Update Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events Spring 2016 ...

  7. Dounreay Shuffler diagnostic software operations manual

    SciTech Connect

    Eccleston, G.W.; Stuewe, B.; Klosterbuer, S.; Van Lyssel, T.

    1985-07-01

    This operations manual describes the test software for the Dounreay Shuffler. The Shuffler is an assay system, controlled by a Commodore PET computer, that measures the plutonium content in leached hulls at the fuel reprocessing plant in Dounreay, Scotland. The Shuffler contains a /sup 252/Cf neutron source that is moved between storage and irradiation locations to obtain measurement data. A stepping motor control (SMC) module operates the Shuffler and accepts commands from the PET to move the source. This manual briefly describes the Shuffler and provides details on running and using the diagnostic software program. The communications protocol for message transmittal between the PET and SMC is defined and a detailed example of message sending is presented in an appendix.

  8. A Three-Dimensional Receiver Operator Characteristic Surface Diagnostic Metric

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2011-01-01

    Receiver Operator Characteristic (ROC) curves are commonly applied as metrics for quantifying the performance of binary fault detection systems. An ROC curve provides a visual representation of a detection system s True Positive Rate versus False Positive Rate sensitivity as the detection threshold is varied. The area under the curve provides a measure of fault detection performance independent of the applied detection threshold. While the standard ROC curve is well suited for quantifying binary fault detection performance, it is not suitable for quantifying the classification performance of multi-fault classification problems. Furthermore, it does not provide a measure of diagnostic latency. To address these shortcomings, a novel three-dimensional receiver operator characteristic (3D ROC) surface metric has been developed. This is done by generating and applying two separate curves: the standard ROC curve reflecting fault detection performance, and a second curve reflecting fault classification performance. A third dimension, diagnostic latency, is added giving rise to 3D ROC surfaces. Applying numerical integration techniques, the volumes under and between the surfaces are calculated to produce metrics of the diagnostic system s detection and classification performance. This paper will describe the 3D ROC surface metric in detail, and present an example of its application for quantifying the performance of aircraft engine gas path diagnostic methods. Metric limitations and potential enhancements are also discussed

  9. Application of diagnostics to determine motor-operated valve operational readiness

    SciTech Connect

    Eissenberg, D.M.

    1986-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor curent signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment.

  10. Tomographic methods in flow diagnostics

    NASA Technical Reports Server (NTRS)

    Decker, Arthur J.

    1993-01-01

    This report presents a viewpoint of tomography that should be well adapted to currently available optical measurement technology as well as the needs of computational and experimental fluid dynamists. The goals in mind are to record data with the fastest optical array sensors; process the data with the fastest parallel processing technology available for small computers; and generate results for both experimental and theoretical data. An in-depth example treats interferometric data as it might be recorded in an aeronautics test facility, but the results are applicable whenever fluid properties are to be measured or applied from projections of those properties. The paper discusses both computed and neural net calibration tomography. The report also contains an overview of key definitions and computational methods, key references, computational problems such as ill-posedness, artifacts, missing data, and some possible and current research topics.

  11. Cryptosporidiosis: multiattribute evaluation of six diagnostic methods.

    PubMed

    MacPherson, D W; McQueen, R

    1993-02-01

    Six diagnostic methods (Giemsa staining, Ziehl-Neelsen staining, auramine-rhodamine staining, Sheather's sugar flotation, an indirect immunofluorescence procedure, and a modified concentration-sugar flotation method) for the detection of Cryptosporidium spp. in stool specimens were compared on the following attributes: diagnostic yield, cost to perform each test, ease of handling, and ability to process large numbers of specimens for screening purposes by batching. A rank ordering from least desirable to most desirable was then established for each method by using the study attributes. The process of decision analysis with respect to the laboratory diagnosis of cryptosporidiosis is discussed through the application of multiattribute utility theory to the rank ordering of the study criteria. Within a specific health care setting, a diagnostic facility will be able to calculate its own utility scores for our study attributes. Multiattribute evaluation and analysis are potentially powerful tools in the allocation of resources in the laboratory.

  12. Trends in Laboratory Diagnostic Methods in Periodontology.

    PubMed

    Bolerázska, Beáta; Mareková, Mária; Markovská, Neda

    2016-01-01

    This work presents a summary of current knowledge on the laboratory diagnosis of periodontitis. It focuses on the theoretical foundations and is supplemented with new knowledge. It subsequently describes specifically the laboratory diagnosis methods of periodontitis: the protein expression of inflammation, oral microbiology and molecular diagnostics. Periodontitis is a serious disease worldwide and its confirmed association with systemic diseases means its severity is increasing. Its laboratory diagnosis has the potential to rise to the level of clinical and diagnostic imaging. The transfer of diagnostic methods from laboratory to clinical use is increasingly used in the prevention and monitoring of the exacerbation and treatment of periodontal disease, as well as of its impact on systemic disease. PMID:27131349

  13. [Culture based diagnostic methods for tuberculosis].

    PubMed

    Baylan, Orhan

    2005-01-01

    Culture methods providing isolates for identification and drug susceptibility testing, still represent the gold standard for the definitive diagnosis of tuberculosis, although the delay in obtaining results still remains a problem. Traditional solid media are recommended for use along with liquid media in primary isolation of mycobacteria. At present, a number of elaborate culture systems are available commercially. They range from simple bottles and tubes such as MGIT (BD Diagnostic Systems, USA), Septi-Chek AFB (BD, USA) and MB Redox (Biotest Diagnostics, USA) to semiautomated system (BACTEC 460TB, BD, USA) and fully automated systems (BACTEC 9000 MB [BD, USA], BACTEC MGIT 960 [BD, USA], ESP Culture System II [Trek Diagnostics, USA], MB/BacT ALERT 3D System [BioMérieux, NC], TK Culture System [Salubris Inc, Turkey]). Culture methods available today are sufficient to permit laboratories to develop an algoritm that is optimal for patients and administrative needs. In this review article, the culture systems used for the diagnosis of tuberculosis, their mechanisms, advantages and disadvantages have been discussed under the light of recent literature.

  14. JET diagnostic enhancements in preparation for DT operations

    NASA Astrophysics Data System (ADS)

    Figueiredo, J.; Murari, A.; Perez Von Thun, C.; Marocco, D.; Tardocchi, M.; Belli, F.; García Muñoz, M.; Silva, A.; Soare, S.; Craciunescu, T.; Santala, M.; Blanchard, P.; Balboa, I.; Hawkes, N.

    2016-11-01

    In order to complete the exploitation of the JET ITER-like Wall and to take full benefit from deuterium-tritium experiments on JET, a set of diagnostic system refurbishments or upgrades is in progress. These diagnostic enhancements focus mainly on neutron, gamma, fast ions, instabilities, and operations support. These efforts intend to provide better spatial, temporal, and energy resolution while increasing measurement coverage. Also previously non-existing capabilities, such as Doppler reflectometry is now available for scientific exploitation. Guaranteeing diagnostic reliability and consistency during the expected DT conditions is also a critical objective of the work and systems being implemented. An overview of status and scope of the ongoing projects is presented.

  15. Non-invasive diagnostic methods in dentistry

    NASA Astrophysics Data System (ADS)

    Todea, Carmen

    2016-03-01

    The paper, will present the most important non-invasive methods for diagnostic, in different fields of dentistry. Moreover, the laser-based methods will be emphasis. In orthodontics, 3D laser scanners are increasingly being used to establish database for normative population and cross-sectional growth changes but also to asses clinical outcomes in orthognatic surgical and non-surgical treatments. In prevention the main methods for diagnostic of demineralization and caries detection in early stages are represented by laser fluorescence - Quantitative Light Florescence (QLF); DiagnoDent-system-655nm; FOTI-Fiberoptic transillumination; DIFOTI-Digital Imaging Fiberoptic transillumination; and Optical Coherence Tomography (OCT). In odontology, Laser Doppler Flowmetry (LDF) is a noninvasive real time method used for determining the tooth vitality by monitoring the pulp microcirculation in traumatized teeth, fractured teeth, and teeth undergoing different conservative treatments. In periodontology, recently study shows the ability of LDF to evaluate the health of gingival tissue in periodontal tissue diseases but also after different periodontal treatments.

  16. Method of azimuthally stable Mueller-matrix diagnostics of blood plasma polycrystalline films in cancer diagnostics

    NASA Astrophysics Data System (ADS)

    Ushenko, Yu. A.; Prysyazhnyuk, V. P.; Gavrylyak, M. S.; Gorsky, M. P.; Bachinskiy, V. T.; Vanchuliak, O. Ya.

    2015-02-01

    A new information optical technique of diagnostics of the structure of polycrystalline films of blood plasma is proposed. The model of Mueller-matrix description of mechanisms of optical anisotropy of such objects as optical activity, birefringence, as well as linear and circular dichroism is suggested. The ensemble of informationally topical azimuthally stable Mueller-matrix invariants is determined. Within the statistical analysis of such parameters distributions the objective criteria of differentiation of films of blood plasma taken from healthy and patients with liver cirrhosis were determined. From the point of view of probative medicine the operational characteristics (sensitivity, specificity and accuracy) of the information-optical method of Mueller-matrix mapping of polycrystalline films of blood plasma were found and its efficiency in diagnostics of liver cirrhosis was demonstrated. Prospects of application of the method in experimental medicine to differentiate postmortem changes of the myocardial tissue was examined.

  17. [Chlamydia pneumoniae infections--diagnostic methods].

    PubMed

    Stepień, Ewa; Pieniazek, Piotr; Branicka, Agnieszka; Bozek, Maria

    2002-01-01

    Gram-negative bacteria Chlamydia pneumonia was found in 1989 to cause acute and chronic respiratory tract infections. This agent has been as well associated with other disease: atherogenesis and coronary heart disease. This study is aimed both at making an introduction to the issues related to C. pneumoniae diagnosis and presenting contemporary laboratory methods. Given the limitations of traditional diagnostics methods, serodiagnosis (EIA) and nucleic acids amplification (PCR, hybridisation) provide the most convincing evidence of C. pneumoniae infections. Culture and direct fluorescence antibody (DFA) may be useful in confirming these results. A variety of methods applied can provide an opportunity to detect bacteria in different clinical samples--incl. sputum, nasopharyngeal and throat swabs, bronchoalveolar lavage (BAL) and tissues from biopsy and autopsy. PMID:12184026

  18. Performance of different categories of operators in simulated diagnostic colonoscopy.

    PubMed

    Fasoli, Renato; Pertile, Riccardo; Seligman, Sonia; de Pretis, Giovanni

    2015-01-01

    The possible involvement, although limited to the diagnostic phase of the procedure, of nonmedical staff (particularly endoscopy nurses) in lower digestive endoscopy has recently been suggested. Computer-based simulators have demonstrated objective evaluation of technical skills in digestive endoscopy. The aim of this study was to evaluate basic colonoscopy skills of endoscopy nurses (naive operators), as compared with junior physician staff and senior endoscopists, through a virtual reality colonoscopy simulator. In this single-center, prospective, nonrandomized study, 3 groups of digestive endoscopy operators (endoscopy nurses, junior doctors [<150 previous colonoscopies], expert doctors [>500 previous colonoscopies and >200/year]) completed six diagnostic cases generated by an endoscopic simulator (AccuTouch, Immersion Medical, Gaithersburg, MD). The performance parameters, collected by the simulator, were compared between groups. Five parameters have been considered for statistical analysis: time spent to reach the cecum; pain of any degree; severe/extreme pain; amount of insufflated air; percentage of visualized mucosa. Statistical analysis to compare the three groups has been performed by means of Wilcoxon test for two independent samples and by means of Kruskal-Wallis test for three independent samples (p < .05). Sixteen operators have been studied (six endoscopy nurses, five junior doctors, and five senior doctors); 96 colonoscopic procedures have been evaluated. Statistically significant differences between experts and naive operators were observed regarding time to reach the cecum and induction of severe/extreme pain, with both Kruskal-Wallis and Wilcoxon test (p < .05); all other comparisons did not reach statistical significance. Although, as expected, expert doctors exceeded both junior doctors and naive operators in some relevant quality parameters of simulated diagnostic colonoscopies, the results obtained by less expert performers--and particularly

  19. METHOD OF CENTRIFUGE OPERATION

    DOEpatents

    Cohen, K.

    1960-05-10

    A method of isotope separation is described in which two streams are flowed axially of, and countercurrently through, a cylindrical centrifuge bowl. Under the influence of a centrifugal field, the light fraction is concentrated in a stream flowing through the central portion of the bowl, whereas the heavy fraction is concentrated in a stream at the periphery thereof.

  20. [Categorical and dimensional diagnostic approach to acute psychosis in view of operational diagnostic criteria].

    PubMed

    Sakamoto, Kaoru

    2011-01-01

    "Acute psychosis" is the tentative diagnosis made for the patients presenting acute onset of delusion, hallucination, confusion and emotional instability. "Acute psychosis" was focused in view of operational diagnostic criteria, ie, DSM-IV-TR and ICD-10. The diagnostic categories in the DSM-IV-TR corresponding to "acute psychosis" were brief psychotic disorder, schizophreniform disorder, schizo-affective disorder and mood disorder with psychotic features. Although brief psychotic disorder is representative of "acute psychosis" in the DSM-TR, it lacks in clinical usefulness, because its diagnostic criteria, based on no historical background, lack clinical validity in terms of symptom definition and duration (1 month>). On the other hand, in the ICD-10, a diagnostic category of acute transient psychotic disorder was based on the traditional "acute psychosis" concept that has been bred in the European Psychiatry. Among the acute transient psychotic disorders, acute polymorphic psychotic disorder is the diagnostic category made according to traditional concept of "bouffées délirantes" and cycloid psychosis. It is a clinically useful diagnostic category, because it could predict favorable episode outcome, if a person with fairly good premorbid social adaptation presents acute onset of polymorphic psychotic symptoms. One of the most prominent points of the revision of DSM-IV-TR to DSM-5 is the adoption of dimensional approach evaluation (diagnosis) in a disorder-crossing fashion. In addition to insomnia, depressive mood and anxiety, symptomatic domain such as acute onset, bipolarity, polymorphism of psychotic symptoms, and furthermore such domain as premorbid social adaptation, life event and episode outcome should be evaluated in the course of treatment, contributing to the clinical practice of the patients with acute psychosis. PMID:22352007

  1. Monitoring and diagnostics systems for nuclear power plant operating regimes

    SciTech Connect

    Abagyan, A.A.; Dmitriev, V.M.; Klebanov, L.A.; Kroshilin, A.E.; Larin, E.P.; Morozov, S.K.

    1988-05-01

    The development of new monitoring and diagnostics systems for Soviet reactors is discussed. An experimental test station is described where industrial operation of new experimental systems can be conducted for purposes of bringing their performance to the level of standard Soviet systems for monitoring reactor operation regimes and equipment resources. The requirements and parameters of the systems are described on a unit-by-unit basis, including the sensor reading monitoring unit, the vibroacoustic monitoring unit, the noise monitoring unit, the accident regime identification unit, and the nonstationary regime monitoring unit. Computer hardware and software requirements are discussed. The results of calculational and experimental research on two complex nonstationary regimes of reactor operation are given. The accident regimes identification unit for the VVER-1000 is analyzed in detail.

  2. Ultrasensitive microanalytical diagnostic methods for rickettsial pathogens

    SciTech Connect

    Hatch, A. V.

    2012-03-01

    A strategic CRADA was established between Sandia National Laboratories (SNL) and the University of Texas Medical Branch (UTMB) at Galveston to address pressing needs for US protection against biological weapons of mass destruction (WMD) and emerging infectious diseases. The combination of unique expertise and facilities at UTMB and SNL enabled interdisciplinary research efforts in the development of rapid and accurate diagnostic methods for early detection of trace priority pathogen levels. Outstanding postdoctoral students were also trained at both institutions to help enable the next generation of scientists to tackle the challenging interdisciplinary problems in the area of biodefense and emerging infectious diseases. Novel approaches to diagnostics were developed and the both the speed of assays as well as the detection sensitivity were improved by over an order of magnitude compared to traditional methods. This is a significant step toward more timely and specific detection of dangerous infections. We developed in situ polymerized porous polymer monoliths that can be used as (1) size exclusion elements for capture and processing of rickettsial infected cells from a sample, (2) photopatternable framework for grafting high densities of functionalized antibodies/fluorescent particles using novel monolith chemistry. Grafting affinity reagents specific to rickettsial particles enables rapid, ultra-sensitive assays by overcoming transport limitations of traditional planar assay approaches. We have selectively trapped particles and bacteria at the cell trap and have also detected picomolar mouse IL-6 captured with only 20 minutes total incubation times using the densely patterned monolith framework. As predicted, the monolith exhibits >10x improvements in both capture speed and capture density compared to traditional planar approaches. The most significant advancements as part of this CRADA is the optimization of techniques allowing the detection of <10 rickettsial

  3. Operation of target diagnostics in a petawatt laser environment (invited)

    SciTech Connect

    Stoeckl, C.; Glebov, V. Yu.; Jaanimagi, P. A.; Knauer, J. P.; Meyerhofer, D. D.; Sangster, T. C.; Storm, M.; Sublett, S.; Theobald, W.; Key, M. H.; MacKinnon, A. J.; Patel, P.; Neely, D.; Norreys, P. A.

    2006-10-15

    The operation of target diagnostics in a high-energy petawatt laser environment is made challenging by the large number of energetic electrons, hard x rays, and energetic particles produced in laser-target interactions. The charged particles and x rays from the target create secondary radiation and a large electromagnetic pulse (EMP) when they hit structures inside the target chamber. The primary particles create secondary particles and radiation that can create excessive background in sensitive detectors. The large EMP can impair or damage electronic equipment and detectors, especially inside the target chamber. Shielding and EMP mitigation strategies developed during experiments at the Rutherford Appleton Vulcan petawatt laser facility will be presented for a variety of detection systems, such as single-photon-counting x-ray charge-coupled device cameras, multiple diamond x-ray detectors, and scintillator-photomultiplier detectors. These strategies will be applied to the development of diagnostic systems for the OMEGA EP, high-energy petawatt laser facility, currently under construction at the Laboratory for Laser Energetics.

  4. Electron-Beam Diagnostic Methods for Hypersonic Flow Diagnostics

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The purpose of this work was the evaluation of the use of electron-bean fluorescence for flow measurements during hypersonic flight. Both analytical and numerical models were developed in this investigation to evaluate quantitatively flow field imaging concepts based upon the electron beam fluorescence technique for use in flight research and wind tunnel applications. Specific models were developed for: (1) fluorescence excitation/emission for nitrogen, (2) rotational fluorescence spectrum for nitrogen, (3) single and multiple scattering of electrons in a variable density medium, (4) spatial and spectral distribution of fluorescence, (5) measurement of rotational temperature and density, (6) optical filter design for fluorescence imaging, and (7) temperature accuracy and signal acquisition time requirements. Application of these models to a typical hypersonic wind tunnel flow is presented. In particular, the capability of simulating the fluorescence resulting from electron impact ionization in a variable density nitrogen or air flow provides the capability to evaluate the design of imaging instruments for flow field mapping. The result of this analysis is a recommendation that quantitative measurements of hypersonic flow fields using electron-bean fluorescence is a tractable method with electron beam energies of 100 keV. With lower electron energies, electron scattering increases with significant beam divergence which makes quantitative imaging difficult. The potential application of the analytical and numerical models developed in this work is in the design of a flow field imaging instrument for use in hypersonic wind tunnels or onboard a flight research vehicle.

  5. Towards Verification of Operational Procedures Using Auto-Generated Diagnostic Trees

    NASA Technical Reports Server (NTRS)

    Kurtoglu, Tolga; Lutz, Robyn; Patterson-Hine, Ann

    2009-01-01

    The design, development, and operation of complex space, lunar and planetary exploration systems require the development of general procedures that describe a detailed set of instructions capturing how mission tasks are performed. For both crewed and uncrewed NASA systems, mission safety and the accomplishment of the scientific mission objectives are highly dependent on the correctness of procedures. In this paper, we describe how to use the auto-generated diagnostic trees from existing diagnostic models to improve the verification of standard operating procedures. Specifically, we introduce a systematic method, namely the Diagnostic Tree for Verification (DTV), developed with the goal of leveraging the information contained within auto-generated diagnostic trees in order to check the correctness of procedures, to streamline the procedures in terms of reducing the number of steps or use of resources in them, and to propose alternative procedural steps adaptive to changing operational conditions. The application of the DTV method to a spacecraft electrical power system shows the feasibility of the approach and its range of capabilities

  6. Diagnostic Assessment of Driver Problems: Volume 2. Assessment Techniques for Operational Users: Final Report.

    ERIC Educational Resources Information Center

    McBride, Robin S.; Stroad, Kenneth W., Jr.

    Volume 2 studies the operational feasibility of the diagnostic assessment of driver problems. Target groups for driver countermeasures are identified from research on diagnostic predictors and performance criteria. A diagnostic assessment model is presented which incorporates assessment techniques that were useful in an operational setting. The…

  7. Status of the diagnostics development for the first operation phase of the stellarator Wendelstein 7-X

    SciTech Connect

    König, R. Biedermann, C.; Burhenn, R.; Endler, M.; Grulke, O.; Hathiramani, D.; Hirsch, M.; Jakubowski, M.; Kornejew, P.; Krychowiak, M.; Langenberg, A.; Laux, M.; Lorenz, A.; Otte, M.; Pasch, E.; Pedersen, T. S.; Schneider, W.; Thomsen, H.; Windisch, T.; Zhang, D.; and others

    2014-11-15

    An overview of the diagnostics which are essential for the first operational phase of Wendelstein 7-X and the set of diagnostics expected to be ready for operation at this time are presented. The ongoing investigations of how to cope with high levels of stray Electron Cyclotron Resonance Heating (ECRH) radiation in the ultraviolet (UV)/visible/infrared (IR) optical diagnostics are described.

  8. Extensions of the operational method

    SciTech Connect

    Silver, G.L.

    1986-08-25

    The operational method of data analysis is used to develop new formulas for first and second derivatives on equidistant, curvilinear data consisting of three or more measurements. Echo functions are used to suggest the paths followed by moving data points, and a method of interpolating into rectangles by non-Euclidean geometry is proposed. 5 refs., 5 tabs.

  9. Method and apparatus for holographic wavefront diagnostics

    DOEpatents

    Toeppen, John S.

    1995-01-01

    A wavefront diagnostic apparatus has an optic and a measuring system. The optic forms a holographic image in response to a beam of light striking a hologram formed on a surface of the optic. The measuring system detects the position of the array of holographic images and compares the positions of the array of holographic images to a reference holographic image.

  10. Method and apparatus for holographic wavefront diagnostics

    DOEpatents

    Toeppen, J.S.

    1995-04-25

    A wavefront diagnostic apparatus has an optic and a measuring system. The optic forms a holographic image in response to a beam of light striking a hologram formed on a surface of the optic. The measuring system detects the position of the array of holographic images and compares the positions of the array of holographic images to a reference holographic image. 3 figs.

  11. Application of modern diagnostic methods to environmental improvement. Annual progress report, October 1994--September 1995

    SciTech Connect

    Shepard, W.S.

    1995-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), an interdisciplinary research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to aid in solving DOE`s nuclear waste problem. The program is a comprehensive effort which includes five focus areas: advanced diagnostic systems; development/application; torch operation and test facilities; process development; on-site field measurement and analysis; technology transfer/commercialization. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and process control. Also, the measured parameters, will be employed to improve, optimize and control the operation of the plasma torch and the overall plasma treatment process. Moreover, on-site field measurements at various DOE facilities are carried out to aid in the rapid demonstration and implementation of modern fieldable diagnostic methods. Such efforts also provide a basis for technology transfer.

  12. [Diagnostic methods of nasal respiratory function].

    PubMed

    Mlynski, G; Beule, A

    2008-01-01

    Objective assessment of nasal obstruction may help with preoperative planning for rhinosurgery and indicate different aspects of endonasal pathology. To improve quality control, preoperative and postoperative objective assessment is desirable. This review presents objective functional diagnostic tools and explains their appropriate uses, the information obtained, and their limitations. An algorithm is presented for analysing nasal obstruction by means of objective functional assessment. Examples illustrate how to use this information for preoperative planning in rhinosurgery. PMID:18210011

  13. A Refined QSO Selection Method Using Diagnostics

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Won; Protopapas, Pavlos; Trichas, Markos; Rowan-Robinson, Michael; Khardon, Roni; Alcock, Charles; Byun, Yong-Ik

    2012-04-01

    We present 663 QSO candidates in the Large Magellanic Cloud (LMC) that were selected using multiple diagnostics. We started with a set of 2,566 QSO candidates selected using the methodology presented in our previous work based on time variability of the MACHO LMC light curves. We then obtained additional information for the candidates by cross-matching them with the Spitzer SAGE, the 2MASS, the Chandra, the XMM, and an LMC UBVI catalogues. Using that information, we specified diagnostic features based on mid-IR colours, photometric redshifts using SED template fitting, and X-ray luminosities, in order to discriminate more high-confidence QSO candidates in the absence of spectral information. We then trained a one-class Support Vector Machine model using those diagnostics features. We applied the trained model to the original candidates, and finally selected 663 high-confidence QSO candidates. We cross-matched those 663 QSO candidates with 152 newly-confirmed QSOs and 275 non-QSOs in the LMC fields, and found that the false positive rate was less than 1%.

  14. Aircraft Engine Gas Path Diagnostic Methods: Public Benchmarking Results

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Borguet, Sebastien; Leonard, Olivier; Zhang, Xiaodong (Frank)

    2013-01-01

    Recent technology reviews have identified the need for objective assessments of aircraft engine health management (EHM) technologies. To help address this issue, a gas path diagnostic benchmark problem has been created and made publicly available. This software tool, referred to as the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES), has been constructed based on feedback provided by the aircraft EHM community. It provides a standard benchmark problem enabling users to develop, evaluate and compare diagnostic methods. This paper will present an overview of ProDiMES along with a description of four gas path diagnostic methods developed and applied to the problem. These methods, which include analytical and empirical diagnostic techniques, will be described and associated blind-test-case metric results will be presented and compared. Lessons learned along with recommendations for improving the public benchmarking processes will also be presented and discussed.

  15. Pertussis: the disease and new diagnostic methods.

    PubMed Central

    Friedman, R L

    1988-01-01

    Bordetella pertussis, the causative agent of whooping cough, produces an acute and chronic respiratory infection in infants and young children. B. pertussis is still a major health problem of young children throughout the world even though effective immunization against whooping cough is available. While predominantly a childhood disease, it has been reported also to be a cause of persistent cough in adults. This review discusses the numerous bacterial virulence factors that may play roles in the pathogenesis of pertussis and in immunity to infection. The present problems with pertussis diagnosis, recent advances, and future prospects for new and improved rapid diagnostics tests also are explored. PMID:2906814

  16. METHOD OF OPERATING A CALUTRON

    DOEpatents

    Davidson, P.H.

    1960-01-12

    A method of operating an electromagnetic isotope separator of the calutron class is reported whereby uranium tetrachloride is produced at a controlled rate within the source rather than betng introduced therein as was formerly practiced. This is accomplished by placing a uranium-bearing material, such as uranium metal, uranium trichloride, or uranium carbide in the charge receptacle of the calutron, heating this material to about to produce uranium tetrachloride vapor at a rate controlled by the chlorine gas flow into the source. The vapor is subsequently ionized by an electric arc and mass separated by conventional calutron methods.

  17. Method and system for diagnostics of apparatus

    NASA Technical Reports Server (NTRS)

    Gorinevsky, Dimitry (Inventor)

    2012-01-01

    Proposed is a method, implemented in software, for estimating fault state of an apparatus outfitted with sensors. At each execution period the method processes sensor data from the apparatus to obtain a set of parity parameters, which are further used for estimating fault state. The estimation method formulates a convex optimization problem for each fault hypothesis and employs a convex solver to compute fault parameter estimates and fault likelihoods for each fault hypothesis. The highest likelihoods and corresponding parameter estimates are transmitted to a display device or an automated decision and control system. The obtained accurate estimate of fault state can be used to improve safety, performance, or maintenance processes for the apparatus.

  18. Propulsion Diagnostic Method Evaluation Strategy (ProDiMES) User's Guide

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2010-01-01

    This report is a User's Guide for the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES). ProDiMES is a standard benchmarking problem and a set of evaluation metrics to enable the comparison of candidate aircraft engine gas path diagnostic methods. This Matlab (The Mathworks, Inc.) based software tool enables users to independently develop and evaluate diagnostic methods. Additionally, a set of blind test case data is also distributed as part of the software. This will enable the side-by-side comparison of diagnostic approaches developed by multiple users. The Users Guide describes the various components of ProDiMES, and provides instructions for the installation and operation of the tool.

  19. Diagnostic Value of Halitosis Examination Methods.

    PubMed

    Aydin, Murat; Bollen, Curd M L; Özen, Murat Eren

    2016-03-01

    There are many methods and varied protocols for examining halitosis. Chemical and enzymatic tests determine the presence of bacterial species and their metabolic products or enzymes in the mouth, while halitometers precisely quantify gases but not halitosis itself. Examinations by the human nose (ie, self assessment, feedback from others, or organoleptic test by an examiner) directly target halitosis, however organoleptic examination alone is insufficient for a definitive diagnosis when the individual has no complaints about halitosis. The underlying reasons why patients seek consultation concerning halitosis are usually based on their own assessment and the opinion of others, even if those assessments are not correlated with oral odorous gas measurements. This article seeks to summarize findings and review methods of examining halitosis to determine their usefulness. PMID:26977897

  20. METHOD OF OPERATING NUCLEAR REACTORS

    DOEpatents

    Untermyer, S.

    1958-10-14

    A method is presented for obtaining enhanced utilization of natural uranium in heavy water moderated nuclear reactors by charging the reactor with an equal number of fuel elements formed of natural uranium and of fuel elements formed of uranium depleted in U/sup 235/ to the extent that the combination will just support a chain reaction. The reactor is operated until the rate of burnup of plutonium equals its rate of production, the fuel elements are processed to recover plutonium, the depleted uranium is discarded, and the remaining uranium is formed into fuel elements. These fuel elements are charged into a reactor along with an equal number of fuel elements formed of uranium depleted in U/sup 235/ to the extent that the combination will just support a chain reaction, and reuse of the uranium is continued as aforesaid until it wlll no longer support a chain reaction when combined with an equal quantity of natural uranium.

  1. Signal processing methods for MFE plasma diagnostics

    SciTech Connect

    Candy, J.V.; Casper, T.; Kane, R.

    1985-02-01

    The application of various signal processing methods to extract energy storage information from plasma diamagnetism sensors occurring during physics experiments on the Tandom Mirror Experiment-Upgrade (TMX-U) is discussed. We show how these processing techniques can be used to decrease the uncertainty in the corresponding sensor measurements. The algorithms suggested are implemented using SIG, an interactive signal processing package developed at LLNL.

  2. Potentials and limitations of molecular diagnostic methods in food safety

    PubMed Central

    Mariani, Paola O.

    2008-01-01

    Molecular methods allow the detection of pathogen nucleic acids (DNA and RNA) and, therefore, the detection of contamination in food is carried out with high selectivity and rapidity. In the last 2 decades molecular methods have accompanied traditional diagnostic methods in routine pathogen detection, and might replace them in the upcoming future. In this review the implementation in diagnostics of four of the most used molecular techniques (PCR, NASBA, microarray, LDR) are described and compared, highlighting advantages and limitations of each of them. Drawbacks of molecular methods with regard to traditional ones and the difficulties encountered in pathogen detection from food or clinical specimen are also discussed. Moreover, criteria for the choice of the target sequence for a secure detection and classification of pathogens and possible developments in molecular diagnostics are also proposed. PMID:19067016

  3. New diagnostic methods for esophageal carcinoma.

    PubMed

    Bohorfoush, A G

    2000-01-01

    The increasingly severe problem of esophageal carcinoma on world public health merits the application of new endoscopic methods to assist in early detection and screening. Older methods, such as tissue staining, combined with magnification endoscopy, have shown promising results, while newer techniques capitalize on measurements that discriminate benign from malignant cells based on a wide array of different attributes, ranging from the molecular to the macroscopic level. Instrumentation based on laser-induced fluorescence spectroscopy, ratio fluorescence imaging, elastic scattering spectroscopy, Raman spectroscopy, and optical coherence tomography is presently being tested and compared with standard endoscopic techniques. Using pathologic interpretation of pinch biopsies as the "gold standard," these techniques have shown the ability to identify dysplastic or malignant regions of tissue that would not be visible to the unassisted endoscopist and offer increased sensitivity for detection compared to rigorous random biopsy protocols. The rapid speed of the instruments allows the provision of information to the endoscopist almost instantaneously, potentially allowing therapeutic decisions to be conducted within the confines of the same endoscopic procedure, thereby achieving gains in efficiency and reductions in overall cost. Large, multicenter trials will be necessary to determine the sensitivity and specificity of individual and combined techniques, as well as their ability to favorably influence the early detection, management, and overall outcome of this disease.

  4. Computer methods for ITER-like materials LIBS diagnostics

    NASA Astrophysics Data System (ADS)

    Łepek, Michał; Gąsior, Paweł

    2014-11-01

    Recent development of Laser-Induced Breakdown Spectroscopy (LIBS) caused that this method is considered as the most promising for future diagnostic applications for characterization of the deposited materials in the International Thermonuclear Experimental Reactor (ITER), which is currently under construction. In this article the basics of LIBS are shortly discussed and the software for spectra analyzing is presented. The main software function is to analyze measured spectra with respect to the certain element lines presence. Some program operation results are presented. Correct results for graphite and aluminum are obtained although identification of tungsten lines is a problem. The reason for this is low tungsten lines intensity, and thus low signal to noise ratio of the measured signal. In the second part artificial neural networks (ANNs) as the next step for LIBS spectra analyzing are proposed. The idea is focused on multilayer perceptron network (MLP) with backpropagation learning method. The potential of ANNs for data processing was proved through application in several LIBS-related domains, e.g. differentiating ancient Greek ceramics (discussed). The idea is to apply an ANN for determination of W, Al, C presence on ITER-like plasma-facing materials.

  5. Differential temperature integrating diagnostic method and apparatus

    DOEpatents

    Doss, James D.; McCabe, Charles W.

    1976-01-01

    A method and device for detecting the presence of breast cancer in women by integrating the temperature difference between the temperature of a normal breast and that of a breast having a malignant tumor. The breast-receiving cups of a brassiere are each provided with thermally conductive material next to the skin, with a thermistor attached to the thermally conductive material in each cup. The thermistors are connected to adjacent arms of a Wheatstone bridge. Unbalance currents in the bridge are integrated with respect to time by means of an electrochemical integrator. In the absence of a tumor, both breasts maintain substantially the same temperature, and the bridge remains balanced. If the tumor is present in one breast, a higher temperature in that breast unbalances the bridge and the electrochemical cells integrate the temperature difference with respect to time.

  6. Aircraft operability methods applied to space launch vehicles

    NASA Astrophysics Data System (ADS)

    Young, Douglas

    1997-01-01

    The commercial space launch market requirement for low vehicle operations costs necessitates the application of methods and technologies developed and proven for complex aircraft systems. The ``building in'' of reliability and maintainability, which is applied extensively in the aircraft industry, has yet to be applied to the maximum extent possible on launch vehicles. Use of vehicle system and structural health monitoring, automated ground systems and diagnostic design methods derived from aircraft applications support the goal of achieving low cost launch vehicle operations. Transforming these operability techniques to space applications where diagnostic effectiveness has significantly different metrics is critical to the success of future launch systems. These concepts will be discussed with reference to broad launch vehicle applicability. Lessons learned and techniques used in the adaptation of these methods will be outlined drawing from recent aircraft programs and implementation on phase 1 of the X-33/RLV technology development program.

  7. Aircraft operability methods applied to space launch vehicles

    SciTech Connect

    Young, D.

    1997-01-01

    The commercial space launch market requirement for low vehicle operations costs necessitates the application of methods and technologies developed and proven for complex aircraft systems. The {open_quotes}building in{close_quotes} of reliability and maintainability, which is applied extensively in the aircraft industry, has yet to be applied to the maximum extent possible on launch vehicles. Use of vehicle system and structural health monitoring, automated ground systems and diagnostic design methods derived from aircraft applications support the goal of achieving low cost launch vehicle operations. Transforming these operability techniques to space applications where diagnostic effectiveness has significantly different metrics is critical to the success of future launch systems. These concepts will be discussed with reference to broad launch vehicle applicability. Lessons learned and techniques used in the adaptation of these methods will be outlined drawing from recent aircraft programs and implementation on phase 1 of the X-33/RLV technology development program. {copyright} {ital 1997 American Institute of Physics.}

  8. Fault Diagnostics for Electrically Operated Pitch Systems in Offshore Wind Turbines

    NASA Astrophysics Data System (ADS)

    Teja Kandukuri, Surya; Khang Huynh, Van; Karimi, Hamid Reza; Robbersmyr, Kjell Gunnar

    2016-09-01

    This paper investigates the electrically operated pitch systems of offshore wind turbines for online condition monitoring and health assessment. The current signature based fault diagnostics is developed for electrically operated pitch systems using model-based approach. The electrical motor faults are firstly modelled based on modified winding function theory and then, current signature analysis is performed to detect the faults. Further, in order to verify the fault diagnostics capabilities in realistic conditions, the operating profiles are obtained from FAST simulation of offshore wind turbines in various wind conditions. In this way, the applicability of current signature analysis for fault diagnostics in offshore wind turbine pitch systems is demonstrated.

  9. [Cognitive functions, their development and modern diagnostic methods].

    PubMed

    Klasik, Adam; Janas-Kozik, Małgorzata; Krupka-Matuszczyk, Irena; Augustyniak, Ewa

    2006-01-01

    provided a theory. The psychometric approach concentrates on studying the differences in intelligence. The aim of this approach is to test intelligence by means of standardized tests (e.g. WISC-R, WAIS-R) used to show the individual differences among humans. Human cognitive functions determine individuals' adaptation capabilities and disturbances in this area indicate a number of psychopathological changes and are a symptom enabling to differentiate or diagnose one with a disorder. That is why the psychological assessment of cognitive functions is an important part of patients' diagnosis. Contemporary neuropsychological studies are to a great extent based computer tests. The use of computer methods has a number of measurement-related advantages. It allows for standardized testing environment, increasing therefore its reliability and standardizes the patient assessment process. Special attention should be paid to the neuropsychological tests included in the Vienna Test System (Cognitron, SIGNAL, RT, VIGIL, DAUF), which are used to assess the operational memory span, learning processes, reaction time, attention selective function, attention continuity as well as attention interference resistance. It also seems justified to present the CPT id test (Continuous Performance Test) as well as Free Recall. CPT is a diagnostic tool used to assess the attention selective function, attention continuity of attention, attention interference resistance as well as attention alertness. The Free Recall test is used in the memory processes diagnostics to assess patients' operational memory as well as the information organization degree in operational memory. The above mentioned neuropsychological tests are tools used in clinical assessment of cognitive function disorders.

  10. [Cognitive functions, their development and modern diagnostic methods].

    PubMed

    Klasik, Adam; Janas-Kozik, Małgorzata; Krupka-Matuszczyk, Irena; Augustyniak, Ewa

    2006-01-01

    provided a theory. The psychometric approach concentrates on studying the differences in intelligence. The aim of this approach is to test intelligence by means of standardized tests (e.g. WISC-R, WAIS-R) used to show the individual differences among humans. Human cognitive functions determine individuals' adaptation capabilities and disturbances in this area indicate a number of psychopathological changes and are a symptom enabling to differentiate or diagnose one with a disorder. That is why the psychological assessment of cognitive functions is an important part of patients' diagnosis. Contemporary neuropsychological studies are to a great extent based computer tests. The use of computer methods has a number of measurement-related advantages. It allows for standardized testing environment, increasing therefore its reliability and standardizes the patient assessment process. Special attention should be paid to the neuropsychological tests included in the Vienna Test System (Cognitron, SIGNAL, RT, VIGIL, DAUF), which are used to assess the operational memory span, learning processes, reaction time, attention selective function, attention continuity as well as attention interference resistance. It also seems justified to present the CPT id test (Continuous Performance Test) as well as Free Recall. CPT is a diagnostic tool used to assess the attention selective function, attention continuity of attention, attention interference resistance as well as attention alertness. The Free Recall test is used in the memory processes diagnostics to assess patients' operational memory as well as the information organization degree in operational memory. The above mentioned neuropsychological tests are tools used in clinical assessment of cognitive function disorders. PMID:17471820

  11. Motor current signature analysis method for diagnosing motor operated devices

    DOEpatents

    Haynes, Howard D.; Eissenberg, David M.

    1990-01-01

    A motor current noise signature analysis method and apparatus for remotely monitoring the operating characteristics of an electric motor-operated device such as a motor-operated valve. Frequency domain signal analysis techniques are applied to a conditioned motor current signal to distinctly identify various operating parameters of the motor driven device from the motor current signature. The signature may be recorded and compared with subsequent signatures to detect operating abnormalities and degradation of the device. This diagnostic method does not require special equipment to be installed on the motor-operated device, and the current sensing may be performed at remote control locations, e.g., where the motor-operated devices are used in accessible or hostile environments.

  12. Image processing methods and architectures in diagnostic pathology.

    PubMed

    Bueno, Gloria; Déniz, Oscar; Salido, Jesús; Rojo, Marcial García

    2009-01-01

    Grid technology has enabled the clustering and the efficient and secure access to and interaction among a wide variety of geographically distributed resources such as: supercomputers, storage systems, data sources, instruments and special devices and services. Their main applications include large-scale computational and data intensive problems in science and engineering. General grid structures and methodologies for both software and hardware in image analysis for virtual tissue-based diagnosis has been considered in this paper. This methods are focus on the user level middleware. The article describes the distributed programming system developed by the authors for virtual slide analysis in diagnostic pathology. The system supports different image analysis operations commonly done in anatomical pathology and it takes into account secured aspects and specialized infrastructures with high level services designed to meet application requirements. Grids are likely to have a deep impact on health related applications, and therefore they seem to be suitable for tissue-based diagnosis too. The implemented system is a joint application that mixes both Web and Grid Service Architecture around a distributed architecture for image processing. It has shown to be a successful solution to analyze a big and heterogeneous group of histological images under architecture of massively parallel processors using message passing and non-shared memory.

  13. Image processing methods and architectures in diagnostic pathology.

    PubMed

    Bueno, Gloria; Déniz, Oscar; Salido, Jesús; Rojo, Marcial García

    2009-01-01

    Grid technology has enabled the clustering and the efficient and secure access to and interaction among a wide variety of geographically distributed resources such as: supercomputers, storage systems, data sources, instruments and special devices and services. Their main applications include large-scale computational and data intensive problems in science and engineering. General grid structures and methodologies for both software and hardware in image analysis for virtual tissue-based diagnosis has been considered in this paper. This methods are focus on the user level middleware. The article describes the distributed programming system developed by the authors for virtual slide analysis in diagnostic pathology. The system supports different image analysis operations commonly done in anatomical pathology and it takes into account secured aspects and specialized infrastructures with high level services designed to meet application requirements. Grids are likely to have a deep impact on health related applications, and therefore they seem to be suitable for tissue-based diagnosis too. The implemented system is a joint application that mixes both Web and Grid Service Architecture around a distributed architecture for image processing. It has shown to be a successful solution to analyze a big and heterogeneous group of histological images under architecture of massively parallel processors using message passing and non-shared memory. PMID:20430740

  14. A method for knowledge acquisition in diagnostic expert system.

    PubMed

    Li, Weishi; Li, Aiping; Li, Shudong

    2015-01-01

    Knowledge acquisition plays very important role in the diagnostic expert system. It usually takes a long period to acquire disease knowledge using the traditional methods. To solve this problem, this paper describes relations between rough set theory and rule-based description of diseases, which corresponds to the process of knowledge acquisition of diagnostic expert system. Then the exclusive rules, inclusive rules and disease images of disease are built based on the PDES diagnosis model, and the definition of probability rule is put forward. At last, the paper presents the rule-based automated induction reasoning method, including exhaustive search, post-processing procedure, estimation for statistic test and the bootstrap and resampling methods. We also introduce automated induction of the rule-based description, which is used in our diseases diagnostic expert system. The experimental results not only show that rough set theory gives a very suitable framework to represent processes of uncertain knowledge extraction, but also that this method induces diagnostic rules correctly. This method can act as the assistant tool for development of diagnosis expert system, and has an extensive application in intelligent information systems.

  15. Method to directly radiolabel antibodies for diagnostic imaging and therapy

    SciTech Connect

    Thakur, M.L.

    1991-04-30

    This patent describes a method for directly labeling proteins with radionuclides for use in diagnostic imaging and therapy. It comprises: the steps of incubating a protein-containing solution with a solution of sodium ascorbate; adding a required quantity of reduced radionuclide to the incubated protein-containing solution and incubating.

  16. Method to directly radiolabel antibodies for diagnostic imaging and therapy

    DOEpatents

    Thakur, Mathew L.

    1991-01-01

    The invention is a novel method and kit for directly radiolabeling proteins such as antibodies or antibody fragments for diagnostic and therapeutic purposes. The method comprises incubating a protein-containing solution with a solution of sodium ascorbate; adding a required quantity of reduced radionuclide to the incubated protein. A kit is also provided wherein the protein and/or reducing agents may be in lyophilized form.

  17. Method to directly radiolabel antibodies for diagnostic imaging and therapy

    DOEpatents

    Thakur, Mathew L.

    1994-01-01

    The invention is a novel method and kit for directly radiolabeling proteins such as antibodies or antibody fragments for diagnostic and therapeutic purposes. The method comprises incubating a protein-containing solution with a solution of sodium ascorbate; adding a required quantity of reduced radionuclide to the incubated protein. A kit is also provided wherein the protein and/or reducing agents may be in lyophilized form.

  18. INITIAL OPERATION OF THE LEDA BEAM-INDUCED FLUORESCENCE DIAGNOSTIC

    SciTech Connect

    J. KAMPERSCHROER; ET AL

    2000-06-01

    A diagnostic based on beam-induced fluorescence has been developed and used to examine the expanded beam in the High-Energy Beam Transport (HEBT) section of the Low Energy Demonstration Accelerator (LEDA). The system consists of a camera, a gas injector, a spectrometer, and a control system. Gas is injected to provide a medium for the beam to excite, the camera captures the resulting image of the fluorescing gas, and the spectrometer measures the spectrum of the emitted light. EPICS was used to control the camera and acquire and store images. Data analysis is presently being performed offline. A Kodak DCS420m professional CCD camera is the primary component of the optical system. InterScience, Inc. modified the camera with the addition of a gain of 4000 image intensifier, thereby producing an intensified camera with a sensitivity of {approximately}0.5 milli-lux. Light is gathered with a 1 inch format, 16-160 mm, Computar zoom lens. This lens is attached to the camera via a Century Precision Optics relay lens. Images obtained using only hydrogen from the beam stop exhibited features not yet understood. Images with good signal-to-noise ratio were obtained with the injection of sufficient nitrogen to raise the HEBT pressure to 2-8x10{sup {minus}6} torr. Two strong nitrogen lines, believed to be of the first negative group of N{sub 2}{sup +}, were identified at 391 and 428 nm.

  19. Molecular Diagnostic Methods for Detection and Characterization of Human Noroviruses

    PubMed Central

    Chen, Haifeng; Hu, Yuan

    2016-01-01

    Human noroviruses are a group of viral agents that afflict people of all age groups. The viruses are now recognized as the most common causative agent of nonbacterial acute gastroenteritis and foodborne viral illness worldwide. However, they have been considered to play insignificant roles in the disease burden of acute gastroenteritis for the past decades until the recent advent of new and more sensitive molecular diagnostic methods. The availability and application of the molecular diagnostic methods have led to enhanced detection of noroviruses in clinical, food and environmental samples, significantly increasing the recognition of noroviruses as an etiologic agent of epidemic and sporadic acute gastroenteritis. This article aims to summarize recent efforts made for the development of molecular methods for the detection and characterization of human noroviruses. PMID:27335620

  20. Patenting genetic diagnostic methods: NGS, GWAS, SNPs and patents.

    PubMed

    Lawson, Charles

    2015-06-01

    This article reviews the problems posed by patent claims to genetic diagnostic methods associated with genome-wide association studies (GWAS) adopting methodologies using next-generation sequencing (NGS) and single nucleotide polymorphisms (SNP). These problems are essentially about experimental reproducibility and the credibility and veracity of reported developments. An analysis of the relevant law demonstrates that the current Australian and United States laws about suitable patentable subject matter differ, and that the current reproducibility (sufficiency, enablement and inutility) standards are unlikely to address these problems. The article concludes that following the United States approach excluding these genetic diagnostic method claims from patenting is one solution. Failing this, improving analysis and quality controls that are now being adopted in the basic research will reduce the nature of the problems, although this will remain problematic for patent examiners and the broader public.

  1. Benchmarking Gas Path Diagnostic Methods: A Public Approach

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.; Bird, Jeff; Davison, Craig; Volponi, Al; Iverson, R. Eugene

    2008-01-01

    Recent technology reviews have identified the need for objective assessments of engine health management (EHM) technology. The need is two-fold: technology developers require relevant data and problems to design and validate new algorithms and techniques while engine system integrators and operators need practical tools to direct development and then evaluate the effectiveness of proposed solutions. This paper presents a publicly available gas path diagnostic benchmark problem that has been developed by the Propulsion and Power Systems Panel of The Technical Cooperation Program (TTCP) to help address these needs. The problem is coded in MATLAB (The MathWorks, Inc.) and coupled with a non-linear turbofan engine simulation to produce "snap-shot" measurements, with relevant noise levels, as if collected from a fleet of engines over their lifetime of use. Each engine within the fleet will experience unique operating and deterioration profiles, and may encounter randomly occurring relevant gas path faults including sensor, actuator and component faults. The challenge to the EHM community is to develop gas path diagnostic algorithms to reliably perform fault detection and isolation. An example solution to the benchmark problem is provided along with associated evaluation metrics. A plan is presented to disseminate this benchmark problem to the engine health management technical community and invite technology solutions.

  2. Expert diagnostics system as a part of analysis software for power mission operations

    NASA Technical Reports Server (NTRS)

    Harris, Jennifer A.; Bahrami, Khosrow A.

    1993-01-01

    The operation of interplanetary spacecraft at JPL has become an increasingly complex activity. This complexity is due to advanced spacecraft designs and ambitious mission objectives which lead to operations requirements that are more demanding than those of any previous mission. For this reason, several productivity enhancement measures are underway at JPL within mission operations, particularly in the spacecraft analysis area. These measures aimed at spacecraft analysis include: the development of a multi-mission, multi-subsystem operations environment; the introduction of automated tools into this environment; and the development of an expert diagnostics system. This paper discusses an effort to integrate the above mentioned productivity enhancement measures. A prototype was developed that integrates an expert diagnostics system into a multi-mission, multi-subsystem operations environment using the Galileo Power / Pyro Subsystem as a testbed. This prototype will be discussed in addition to background information associated with it.

  3. Molecular and Nonmolecular Diagnostic Methods for Invasive Fungal Infections

    PubMed Central

    Arvanitis, Marios; Anagnostou, Theodora; Fuchs, Beth Burgwyn; Caliendo, Angela M.

    2014-01-01

    SUMMARY Invasive fungal infections constitute a serious threat to an ever-growing population of immunocompromised individuals and other individuals at risk. Traditional diagnostic methods, such as histopathology and culture, which are still considered the gold standards, have low sensitivity, which underscores the need for the development of new means of detecting fungal infectious agents. Indeed, novel serologic and molecular techniques have been developed and are currently under clinical evaluation. Tests like the galactomannan antigen test for aspergillosis and the β-glucan test for invasive Candida spp. and molds, as well as other antigen and antibody tests, for Cryptococcus spp., Pneumocystis spp., and dimorphic fungi, have already been established as important diagnostic approaches and are implemented in routine clinical practice. On the other hand, PCR and other molecular approaches, such as matrix-assisted laser desorption ionization (MALDI) and fluorescence in situ hybridization (FISH), have proved promising in clinical trials but still need to undergo standardization before their clinical use can become widespread. The purpose of this review is to highlight the different diagnostic approaches that are currently utilized or under development for invasive fungal infections and to identify their performance characteristics and the challenges associated with their use. PMID:24982319

  4. Application of modern diagnostic methods to environmental improvement. Annual progress report, January--October 1994

    SciTech Connect

    Shepard, W.S.

    1994-12-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL), a research department in the College of Engineering at Mississippi State University (MSU), is under contract with the US Department of Energy (DOE) to develop and apply advanced diagnostic instrumentation and analysis techniques to real world processes; measurements are made in hot, highly corrosive atmospheres in which conventional measurement devices are ineffective. Task 1 of this agreement is concerned with the development and application of various diagnostic methods to characterize the plasma properties, the melt properties and the downstream emissions from a plasma torch facility designed to vitrify mixed waste. Correlation of the measured properties with the operating parameters of the torch will be sought to improve, optimize and control the overall operation of the plasma treatment process. As part of this program, diagnostic methods will be developed and evaluated for characterization, monitoring and control purposes of treatment processes in general. Task 2 of this agreement is concerned with the development of a system to monitor and control the combustion stoichiometry in real time in order to minimize environmental impact and maximize process efficiency. Staged fuel injection is also being studied to minimize NO{sub x} formation.

  5. Prognostic Analysis System and Methods of Operation

    NASA Technical Reports Server (NTRS)

    MacKey, Ryan M. E. (Inventor); Sneddon, Robert (Inventor)

    2014-01-01

    A prognostic analysis system and methods of operating the system are provided. In particular, a prognostic analysis system for the analysis of physical system health applicable to mechanical, electrical, chemical and optical systems and methods of operating the system are described herein.

  6. PCR diagnostic methods for Ascosphaera infections in bees.

    PubMed

    James, R R; Skinner, J S

    2005-10-01

    Fungi in the genus Ascosphaera are the causative agents of chalkbrood, a major disease affecting bee larval viability. Identification of individual Ascosphaera species based on morphological features has been difficult due to a lack of distinguishing characteristics. Most identifications are based on the size and shape of the ascomata, spore balls and conidia. Unfortunately, much overlap occurs in the size of these structures, and some Ascosphaera species will not produce sexual structures in vitro. We report a quick and reliable diagnostic method for identifying Ascosphaera infections in Megachile bees (leafcutting bees) using PCR markers that employ genus-specific primers for Ascosphaera, and species-specific primers for species known to be associated with Megachile spp. Using these methods, species identifications can be performed directly on bees, including asymptomatic individuals. Furthermore, the PCR markers can detect co-infections of multiple Ascosphaera species in a single host. We also identified a marker for Ascosphaera apis, the predominant cause of chalkbrood in Apis mellifera, the honey bee. Our diagnostic methods eliminate the need for culturing samples, and could be used to process a large number of field collected bee larvae. PMID:16214164

  7. Method of operating a thermoelectric generator

    SciTech Connect

    Reynolds, Michael G; Cowgill, Joshua D

    2013-11-05

    A method for operating a thermoelectric generator supplying a variable-load component includes commanding the variable-load component to operate at a first output and determining a first load current and a first load voltage to the variable-load component while operating at the commanded first output. The method also includes commanding the variable-load component to operate at a second output and determining a second load current and a second load voltage to the variable-load component while operating at the commanded second output. The method includes calculating a maximum power output of the thermoelectric generator from the determined first load current and voltage and the determined second load current and voltage, and commanding the variable-load component to operate at a third output. The commanded third output is configured to draw the calculated maximum power output from the thermoelectric generator.

  8. Metabolomics-Based Methods for Early Disease Diagnostics: A Review

    PubMed Central

    Nagana Gowda, G. A.; Zhang, Shucha; Gu, Haiwei; Asiago, Vincent; Shanaiah, Narasimhamurthy; Raftery, Daniel

    2013-01-01

    The emerging field of “metabolomics,” in which a large number of small molecule metabolites from body fluids or tissues are detected quantitatively in a single step, promises immense potential for early diagnosis, therapy monitoring and for understanding the pathogenesis of many diseases. Metabolomics methods are mostly focused on the information rich analytical techniques of nuclear magnetic resonance (NMR) spectroscopy and mass spectrometry (MS). Analysis of the data from these high-resolution methods using advanced chemometric approaches provides a powerful platform for translational and clinical research, and diagnostic applications. In this review, the current trends and recent advances in NMR- and MS-based metabolomics are described with a focus on the development of advanced NMR and MS methods, improved multivariate statistical data analysis and recent applications in the area of cancer, diabetes, inborn errors of metabolism, and cardiovascular diseases. PMID:18785810

  9. Real time diagnostic for operation at a CW low voltage FEL

    SciTech Connect

    Balfour, C.; Shaw, A.; Mayhew, S.E.

    1995-12-31

    At Liverpool University, a system for single user control of an FEL has been designed to satisfy the low voltage FEL (ie 200kV) operational requirements. This system incorporates many aspects of computer automation for beam diagnostics, radiation detection and vacuum system management. In this paper the results of the development of safety critical control systems critical control systems are reported.

  10. Study on Fault Diagnostics of a Turboprop Engine Using Inverse Performance Model and Artificial Intelligent Methods

    NASA Astrophysics Data System (ADS)

    Kong, Changduk; Lim, Semyeong

    2011-12-01

    Recently, the health monitoring system of major gas path components of gas turbine uses mostly the model based method like the Gas Path Analysis (GPA). This method is to find quantity changes of component performance characteristic parameters such as isentropic efficiency and mass flow parameter by comparing between measured engine performance parameters such as temperatures, pressures, rotational speeds, fuel consumption, etc. and clean engine performance parameters without any engine faults which are calculated by the base engine performance model. Currently, the expert engine diagnostic systems using the artificial intelligent methods such as Neural Networks (NNs), Fuzzy Logic and Genetic Algorithms (GAs) have been studied to improve the model based method. Among them the NNs are mostly used to the engine fault diagnostic system due to its good learning performance, but it has a drawback due to low accuracy and long learning time to build learning data base if there are large amount of learning data. In addition, it has a very complex structure for finding effectively single type faults or multiple type faults of gas path components. This work builds inversely a base performance model of a turboprop engine to be used for a high altitude operation UAV using measured performance data, and proposes a fault diagnostic system using the base engine performance model and the artificial intelligent methods such as Fuzzy logic and Neural Network. The proposed diagnostic system isolates firstly the faulted components using Fuzzy Logic, then quantifies faults of the identified components using the NN leaned by fault learning data base, which are obtained from the developed base performance model. In leaning the NN, the Feed Forward Back Propagation (FFBP) method is used. Finally, it is verified through several test examples that the component faults implanted arbitrarily in the engine are well isolated and quantified by the proposed diagnostic system.

  11. Comparison of diagnostic laboratory methods for identification of Burkholderia pseudomallei.

    PubMed

    Inglis, Timothy J J; Merritt, Adam; Chidlow, Glenys; Aravena-Roman, Max; Harnett, Gerry

    2005-05-01

    Limited experience and a lack of validated diagnostic reagents make Burkholderia pseudomallei, the cause of melioidosis, difficult to recognize in the diagnostic microbiology laboratory. We compared three methods of confirming the identity of presumptive B. pseudomallei strains using a collection of Burkholderia species drawn from diverse geographic, clinical, and environmental sources. The 95 isolates studied included 71 B. pseudomallei and 3 B. thailandensis isolates. The API 20NE method identified only 37% of the B. pseudomallei isolates. The agglutinating antibody test identified 82% at first the attempt and 90% including results of a repeat test with previously negative isolates. Gas-liquid chromatography analysis of bacterial fatty acid methyl esters (GLC-FAME) identified 98% of the B. pseudomallei isolates. The agglutination test produced four false positive results, one B. cepacia, one B. multivorans, and two B. thailandensis. API produced three false positive results, one positive B. cepacia and two positive B. thailandensis. GLC-FAME analysis was positive for one B. cepacia isolate. On the basis of these results, the most robust B. pseudomallei discovery pathway combines the previously recommended isolate screening tests (Gram stain, oxidase test, gentamicin and polymyxin susceptibility) with monoclonal antibody agglutination on primary culture, followed by a repeat after 24 h incubation on agglutination-negative isolates and GLC-FAME analysis. Incorporation of PCR-based identification within this schema may improve percentages of recognition further but requires more detailed evaluation. PMID:15872242

  12. Methods in virus diagnostics: from ELISA to next generation sequencing.

    PubMed

    Boonham, Neil; Kreuze, Jan; Winter, Stephan; van der Vlugt, René; Bergervoet, Jan; Tomlinson, Jenny; Mumford, Rick

    2014-06-24

    Despite the seemingly continuous development of newer and ever more elaborate methods for detecting and identifying viruses, very few of these new methods get adopted for routine use in testing laboratories, often despite the many and varied claimed advantages they possess. To understand why the rate of uptake of new technologies is so low, requires a strong understanding of what makes a good routine diagnostic tool to begin. This can be done by looking at the two most successfully established plant virus detection methods: enzyme-linked immunosorbant assay (ELISA) and more recently introduced real-time polymerase chain reaction (PCR). By examining the characteristics of this pair of technologies, it becomes clear that they share many benefits, such as an industry standard format and high levels of repeatability and reproducibility. These combine to make methods that are accessible to testing labs, which are easy to establish and robust in their use, even with new and inexperienced users. Hence, to ensure the establishment of new techniques it is necessary to not only provide benefits not found with ELISA or real-time PCR, but also to provide a platform that is easy to establish and use. In plant virus diagnostics, recent developments can be clustered into three core areas: (1) techniques that can be performed in the field or resource poor locations (e.g., loop-mediated isothermal amplification LAMP); (2) multiplex methods that are able to detect many viruses in a single test (e.g., Luminex bead arrays); and (3) methods suited to virus discovery (e.g., next generation sequencing, NGS). Field based methods are not new, with Lateral Flow Devices (LFDs) for the detection being available for a number of years now. However, the widespread uptake of this technology remains poor. LAMP does offer significant advantages over LFDs, in terms of sensitivity and generic application, but still faces challenges in terms of establishment. It is likely that the main barrier to the

  13. New Methods and Transducer Designs for Ultrasonic Diagnostics and Therapy

    NASA Astrophysics Data System (ADS)

    Rybyanets, A. N.; Naumenko, A. A.; Sapozhnikov, O. A.; Khokhlova, V. A.

    Recent advances in the field of physical acoustics, imaging technologies, piezoelectric materials, and ultrasonic transducer design have led to emerging of novel methods and apparatus for ultrasonic diagnostics, therapy and body aesthetics. The paper presents the results on development and experimental study of different high intensity focused ultrasound (HIFU) transducers. Technological peculiarities of the HIFU transducer design as well as theoretical and numerical models of such transducers and the corresponding HIFU fields are discussed. Several HIFU transducers of different design have been fabricated using different advanced piezoelectric materials. Acoustic field measurements for those transducers have been performed using a calibrated fiber optic hydrophone and an ultrasonic measurement system (UMS). The results of ex vivo experiments with different tissues as well as in vivo experiments with blood vessels are presented that prove the efficacy, safety and selectivity of the developed HIFU transducers and methods.

  14. Plasma diagnostic method using intermodulation frequencies in a Langmuir probe

    SciTech Connect

    Kim, Dong-Hwan; Lee, Hyo-Chang; Kim, Yu-Sin; Chung, Chin-Wook

    2013-08-19

    A plasma diagnostic method using intermodulation frequencies is developed. When dual-frequency (ω{sub 1},ω{sub 2}) voltage signals are applied to a probe, the intermodulation frequencies (ω{sub 2}±ω{sub 1}, ω{sub 2}±2ω{sub 1}) between the signals are generated due to the nonlinearity of the sheath. From the analysis of the intermodulation frequencies, the plasma parameters, such as the electron temperature and the plasma density, can be obtained. The measured plasma parameters from this method are compared to the results from the measured electron energy distribution function, and they are in good agreement. Because the intermodulation currents originated from the plasma not from the stray component of the measurement system, an accurate measurement of the plasma parameters is achievable.

  15. A composite likelihood method for bivariate meta-analysis in diagnostic systematic reviews

    PubMed Central

    Liu, Yulun; Ning, Jing; Nie, Lei; Zhu, Hongjian; Chu, Haitao

    2014-01-01

    Diagnostic systematic review is a vital step in the evaluation of diagnostic technologies. In many applications, it involves pooling pairs of sensitivity and specificity of a dichotomized diagnostic test from multiple studies. We propose a composite likelihood method for bivariate meta-analysis in diagnostic systematic reviews. This method provides an alternative way to make inference on diagnostic measures such as sensitivity, specificity, likelihood ratios and diagnostic odds ratio. Its main advantages over the standard likelihood method are the avoidance of the non-convergence problem, which is non-trivial when the number of studies are relatively small, the computational simplicity and some robustness to model mis-specifications. Simulation studies show that the composite likelihood method maintains high relative efficiency compared to that of the standard likelihood method. We illustrate our method in a diagnostic review of the performance of contemporary diagnostic imaging technologies for detecting metastases in patients with melanoma. PMID:25512146

  16. Application of Diagnostic/Prognostic Methods to Critical Equipment for the Spent Nuclear Fuel Cleanup Program

    SciTech Connect

    Casazza, Lawrence O.; Jarrell, Donald B.; Koehler, Theresa M.; Meador, Richard J.; Wallace, Dale E.

    2002-02-28

    The management of the Spent Nuclear Fuel (SNF) project at the Hanford K-Basin in the 100 N Area has successfully restructured the preventive maintenance, spare parts inventory requirements, and the operator rounds data requirements. In this investigation, they continue to examine the different facets of the operations and maintenance (O&M) of the K-Basin cleanup project in search of additional reliability and cost savings. This report focuses on the initial findings of a team of PNNL engineers engaged to identify potential opportunities for reducing the cost of O&M through the application of advanced diagnostics (fault determination) and prognostics (residual life/reliability determination). The objective is to introduce predictive technologies to eliminate or reduce high impact equipment failures. The PNNL team in conjunction with the SNF engineers found the following major opportunities for cost reduction and/or enhancing reliability: (1) Provide data routing and automated analysis from existing detection systems to a display center that will engage the operations and engineering team. This display will be operator intuitive with system alarms and integrated diagnostic capability. (2) Change operating methods to reduce major transients induced in critical equipment. This would reduce stress levels on critical equipment. (3) Install a limited sensor set on failure prone critical equipment to allow degradation or stressor levels to be monitored and alarmed. This would provide operators and engineers with advance guidance and warning of failure events. Specific methods for implementation of the above improvement opportunities are provided in the recommendations. They include an Integrated Water Treatment System (IWTS) decision support system, introduction of variable frequency drives on certain pump motors, and the addition of limited diagnostic instrumentation on specified critical equipment.

  17. A significant diagnostic method in torture investigation: bone scintigraphy.

    PubMed

    Ozkalipci, Onder; Unuvar, Umit; Sahin, Umit; Irencin, Sukran; Fincanci, Sebnem Korur

    2013-03-10

    Torture appears to be a permanent feature in countries, which have experienced military coups or ruled by oppressive governments in the past, such as Turkey. The Human Rights Foundation of Turkey (HRFT) was established in 1990 to serve torture victims, mainly those who were the victims of the 1980 military regime. Since then the HRFT has been providing rehabilitation and documentation for torture survivors. Bone scintigraphy can be one of the diagnostic methods to reveal trauma, particularly after several years when it is challenging to find any physical or radiological evidence. The HRFT's Istanbul Branch referred 97 of their applicants for bone scintigraphy between 1992 and 2010. In this retrospective survey of 97 cases, 17 of them were female and 80 of them were male. Several aspects were evaluated, including working conditions, change of torture methods practiced in certain time periods, time since torture and duration of exposure to torture in comparison with findings of bone scintigraphies. The torture methods varied from beating to falanga, electric shock, suspension and several other types of torture within the period of practice, although beating was a common denominator among all. The findings were classified according to time since torture and duration of exposure to torture. More than half of the cases (59%) had a detectable bone lesion on bone scintigraphy, and the detectable bone lesion on scintigraphy increased significantly with the duration of exposure to torture, particularly among cases who had been subjected to torture for a longer period (8 days and more). Bone scintigraphy should be considered as a valuable non-invasive diagnostic method to assess and document long term torture practices and/or cases with no detectable marks upon physical examination.

  18. An Operator Method for Evaluating Laplace Transforms

    ERIC Educational Resources Information Center

    Lanoue, B. G.; Yurekli, O.

    2005-01-01

    This note discusses a simple operator technique based on the differentiation and shifting properties of the Laplace transform to find Laplace transforms for various elementary functions. The method is simpler than known integration techniques to evaluate Laplace transforms.

  19. An Analysis of Inhalation Injury Diagnostic Methods and Patient Outcomes.

    PubMed

    Ching, Jessica A; Ching, Yiu-Hei; Shivers, Steven C; Karlnoski, Rachel A; Payne, Wyatt G; Smith, David J

    2016-01-01

    The purpose of this study was to compare patient outcomes according to the method of diagnosing burn inhalation injury. After approval from the American Burn Association, the National Burn Repository Dataset Version 8.0 was queried for patients with a diagnosis of burn inhalation injury. Subgroups were analyzed by diagnostic method as defined by the National Burn Repository. All diagnostic methods listed for each patient were included, comparing mortality, hospital days, intensive care unit (ICU) days, and ventilator days (VDs). Z-tests, t-tests, and linear regression were used with a statistical significance of P value of less than .05. The database query yielded 9775 patients diagnosed with inhalation injury. The greatest increase in mortality was associated with diagnosis by bronchoscopy or carbon monoxide poisoning. A relative increase in hospital days was noted with diagnosis by bronchoscopy (9 days) or history (2 days). A relative increase in ICU days was associated with diagnosis according to bronchoscopy (8 days), clinical findings (2 days), or history (2 days). A relative increase in VDs was associated with diagnosis by bronchoscopy (6 days) or carbon monoxide poisoning (3 days). The combination of diagnosis by bronchoscopy and clinical findings increased the relative difference across all comparison measures. The combination of diagnosis by bronchoscopy and carbon monoxide poisoning exhibited decreased relative differences when compared with bronchoscopy alone. Diagnosis by laryngoscopy showed no mortality or association with poor outcomes. Bronchoscopic evidence of inhalation injury proved most useful, predicting increased mortality, hospital, ICU, and VDs. A combined diagnosis determined by clinical findings and bronchoscopy should be considered for clinical practice. PMID:26594867

  20. Initial operation of a newly developed multichord motional Stark effect diagnostic in KSTAR

    NASA Astrophysics Data System (ADS)

    Chung, J.; Ko, J.; Wi, H.; Messmer, M.; Schenkelaars, S.; Scheffer, M.; Jaspers, R. J. E.

    2016-11-01

    A photo-elastic modulator based 25-chord motional Stark effect (MSE) diagnostic has been successfully developed and commissioned in Korea Superconducting Tokamak Advanced Research. The diagnostic measures the radial magnetic pitch angle profile of the Stark splitting of a D-alpha line at 656.1 nm by the electric field associated with the neutral deuterium heating beam. A tangential view of the neutral beam provides a good spatial resolution of 1-3 cm for covering the major radius from 1.74 m to 2.28 m, and the time resolution is achieved at 10 ms. An in-vessel calibration before the vacuum closing as well as an in situ calibration during the tokamak operation was performed by means of specially designed polarized lighting sources. In this work, we present the final design of the installed MSE diagnostic and the first results of the commissioning.

  1. Operational diagnostics of thermal state and efficiency of steam turbines of TPP and NPP

    NASA Astrophysics Data System (ADS)

    Bozhko, V. V.; Kovalenko, A. N.; Lyapunov, V. M.; Khomenok, L. A.

    2016-05-01

    Various ways for solving complex problems of the strength and operating life of steam turbines of TPP and NPP are studied. Diagnostic characters and technical possibilities for their control during the steam turbine operation are determined. It is shown that the effect of various factors on the reliability, maneuverability, and service life of power installations of TPP and NPP is generally determined by the thermal state of steam-electric generating sets. Leading foreign and domestic manufacturers give major attention to the organization of the control of the thermal state of facilities and the development of systems for accounting ("counter") the service life depletion. Zones of high-temperature sites of shafts and disks with maximum parameters of operating environment are determined. A model for on-line computation of thermal stresses with the diagnostic evaluation of the service life depletion (fatigue accumulation) and forecasting of optimum heating conditions for thermostressed turbine units is briefly stated. An example of a program for diagnostics of the quality of the facility operation is given. The program provides the operative control of thermal stresses and the service life depletion in main units of the turbine under various operation conditions, operates in the real-time mode, calculates and represents currents values of thermal stresses in turbine units, and forms and transmits into the industrial control signals on the occurrence of restrictions with respect to thermal stresses and prohibition of an increase or decrease in the vapor temperature and the load in the case of approaching pressures to maximum permissible ones. In the case of stationary operation conditions, the program computed the current efficiency in high (HPC) and mean (MPC) pressure cylinders.

  2. Pedophilia: an evaluation of diagnostic and risk prediction methods.

    PubMed

    Wilson, Robin J; Abracen, Jeffrey; Looman, Jan; Picheca, Janice E; Ferguson, Meaghan

    2011-06-01

    One hundred thirty child sexual abusers were diagnosed using each of following four methods: (a) phallometric testing, (b) strict application of Diagnostic and Statistical Manual of Mental Disorders (4th ed., text revision [DSM-IV-TR]) criteria, (c) Rapid Risk Assessment of Sex Offender Recidivism (RRASOR) scores, and (d) "expert" diagnoses rendered by a seasoned clinician. Comparative utility and intermethod consistency of these methods are reported, along with recidivism data indicating predictive validity for risk management. Results suggest that inconsistency exists in diagnosing pedophilia, leading to diminished accuracy in risk assessment. Although the RRASOR and DSM-IV-TR methods were significantly correlated with expert ratings, RRASOR and DSM-IV-TR were unrelated to each other. Deviant arousal was not associated with any of the other methods. Only the expert ratings and RRASOR scores were predictive of sexual recidivism. Logistic regression analyses showed that expert diagnosis did not add to prediction of sexual offence recidivism over and above RRASOR alone. Findings are discussed within a context of encouragement of clinical consistency and evidence-based practice regarding treatment and risk management of those who sexually abuse children.

  3. [Imputation methods for missing data in educational diagnostic evaluation].

    PubMed

    Fernández-Alonso, Rubén; Suárez-Álvarez, Javier; Muñiz, José

    2012-02-01

    In the diagnostic evaluation of educational systems, self-reports are commonly used to collect data, both cognitive and orectic. For various reasons, in these self-reports, some of the students' data are frequently missing. The main goal of this research is to compare the performance of different imputation methods for missing data in the context of the evaluation of educational systems. On an empirical database of 5,000 subjects, 72 conditions were simulated: three levels of missing data, three types of loss mechanisms, and eight methods of imputation. The levels of missing data were 5%, 10%, and 20%. The loss mechanisms were set at: Missing completely at random, moderately conditioned, and strongly conditioned. The eight imputation methods used were: listwise deletion, replacement by the mean of the scale, by the item mean, the subject mean, the corrected subject mean, multiple regression, and Expectation-Maximization (EM) algorithm, with and without auxiliary variables. The results indicate that the recovery of the data is more accurate when using an appropriate combination of different methods of recovering lost data. When a case is incomplete, the mean of the subject works very well, whereas for completely lost data, multiple imputation with the EM algorithm is recommended. The use of this combination is especially recommended when data loss is greater and its loss mechanism is more conditioned. Lastly, the results are discussed, and some future lines of research are analyzed.

  4. Diagnostic Methods for Platelet Bacteria Screening: Current Status and Developments

    PubMed Central

    Störmer, Melanie; Vollmer, Tanja

    2014-01-01

    Summary Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes. PMID:24659944

  5. Radiative transfer model: matrix operator method.

    PubMed

    Liu, Q; Ruprecht, E

    1996-07-20

    A radiative transfer model, the matrix operator method, is discussed here. The matrix operator method is applied to a plane-parallel atmosphere within three spectral ranges: the visible, the infrared, and the microwave. For a homogeneous layer with spherical scattering, the radiative transfer equation can be solved analytically. The vertically inhomogeneous atmosphere can be subdivided into a set of homogeneous layers. The solution of the radiative transfer equation for the vertically inhomogeneous atmosphere is obtained recurrently from the analytical solutions for the subdivided layers. As an example for the application of the matrix operator method, the effects of the cirrus and the stratocumulus clouds on the net radiation at the surface and at the top of the atmosphere are investigated. The relationship between the polarization in the microwave range and the rain rates is also studied. Copies of the FORTRAN program and the documentation of the FORTRAN program on a diskette are available.

  6. Force Field Analysis: A Bridge Between Diagnostic Data and Operational Prescriptions.

    ERIC Educational Resources Information Center

    Wiener, William K.

    The technique of force field analysis represents a method for bridging the gap between diagnostic data and learning prescriptions and objectives. Through the use of this technique the teacher is able to delineate the strengths and weaknesses of the individual and to generate strategies for meeting specific objectives. A force field refers to a…

  7. Edge Thomson scattering diagnostic on COMPASS tokamak: Installation, calibration, operation, improvements

    SciTech Connect

    Bohm, P. Bilkova, P.; Melich, R.; Sestak, D.; Weinzettl, V.; Stockel, J.; Hron, M.; Panek, R.; Mikulin, O.; Scannell, R.; Naylor, G.; Frassinetti, L.; Fassina, A.; Walsh, M. J.

    2014-11-15

    The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles.

  8. Edge Thomson scattering diagnostic on COMPASS tokamak: installation, calibration, operation, improvements.

    PubMed

    Bohm, P; Aftanas, M; Bilkova, P; Stefanikova, E; Mikulin, O; Melich, R; Janky, F; Havlicek, J; Sestak, D; Weinzettl, V; Stockel, J; Hron, M; Panek, R; Scannell, R; Frassinetti, L; Fassina, A; Naylor, G; Walsh, M J

    2014-11-01

    The core Thomson scattering diagnostic (TS) on the COMPASS tokamak was put in operation and reported earlier. Implementation of edge TS, with spatial resolution along the laser beam up to ∼1/100 of the tokamak minor radius, is presented now. The procedure for spatial calibration and alignment of both core and edge systems is described. Several further upgrades of the TS system, like a triggering unit and piezo motor driven vacuum window shutter, are introduced as well. The edge TS system, together with the core TS, is now in routine operation and provides electron temperature and density profiles.

  9. Differentiating between analytical and diagnostic performance evaluation with a focus on the method comparison study and identification of bias.

    PubMed

    Flatland, Bente; Friedrichs, Kristen R; Klenner, Stefanie

    2014-12-01

    Prior to introduction of a new method to the diagnostic laboratory, analytical performance must be validated to ensure operation within the manufacturer's specifications and/or within predetermined quality requirements. In addition, the new method may require diagnostic performance assessment to ensure it differentiates between diseased and nondiseased individuals as intended. These 2 phases of assessment, while complementary, are not equivalent and require a different set of experiments, statistical analyses, and interpretation. Studies of analytical performance typically include a method comparison experiment, the purpose of which is to identify bias (inaccuracy) of the "test" (or "index") method (new method) relative to a "comparative method" (established method). Analysis of method comparison data is facilitated by commercial software programs that present the statistical significance of identified bias; however, the clinical relevance of any bias also should be considered. Studies of diagnostic performance should not be pursued until analytical performance is fully characterized and may not be required for well-established tests or for those for which results are nonspecific (ie, not referable to a specific disease or condition). Diagnostic performance assessment may include assessment of sensitivity, specificity, predictive values, odds ratios, and/or likelihood ratios. The purpose of this review is to clarify differences between the assessment of analytical and diagnostic performance, and to explore the method comparison study and bias assessment from a perspective not addressed in prior veterinary articles.

  10. METHOD OF OPERATING A NEUTRONIC REACTOR

    DOEpatents

    Turkevich, A.

    1963-01-22

    This patent relates to one step in a method of operating a neutronic reactor consisting of a slurry of fissionable material in heavy water. Deuterium gas is passed through the slurry to sweep gaseous fission products therefrom and the deuterium is then separated from the gaseous fission products. (AEC)

  11. Diagnostic Methods for Bile Acid Malabsorption in Clinical Practice

    PubMed Central

    Vijayvargiya, Priya; Camilleri, Michael; Shin, Andrea; Saenger, Amy

    2013-01-01

    Altered bile acid (BA) concentrations in the colon may cause diarrhea or constipation. BA malabsorption (BAM) accounts for >25% of patients with irritable bowel syndrome (IBS) with diarrhea and chronic diarrhea in Western countries. As BAM is increasingly recognized, proper diagnostic methods are desired in clinical practice to help direct the most effective treatment course for the chronic bowel dysfunction. This review appraises the methodology, advantages and disadvantages of 4 tools that directly measure BAM: 14C-glycocholate breath and stool test, 75Selenium HomotauroCholic Acid Test (SeHCAT), 7 α-hydroxy-4-cholesten-3-one (C4) and fecal BAs. 14C-glycocholate is a laborious test no longer widely utilized. 75SeHCAT is validated, but not available in the United States. Serum C4 is a simple, accurate method that is applicable to a majority of patients, but requires further clinical validation. Fecal measurements to quantify total and individual fecal BAs are technically cumbersome and not widely available. Regrettably, none of these tests are routinely available in the U.S., and a therapeutic trial with a BA binder is used as a surrogate for diagnosis of BAM. Recent data suggest there is an advantage to studying fecal excretion of the individual BAs and their role in BAM; this may constitute a significant advantage of the fecal BA method over the other tests. Fecal BA test could become a routine addition to fecal fat measurement in patients with unexplained diarrhea. In summary, availability determines the choice of test among C4, SeHCAT and fecal BA; more widespread availability of such tests would enhance clinical management of these patients. PMID:23644387

  12. Diagnostic Methods for Detection of Blood-Borne Candidiasis.

    PubMed

    Clancy, Cornelius J; Nguyen, M Hong

    2016-01-01

    β-D-glucan (Fungitell) and polymerase chain reaction-based (T2Candida) assays of blood samples are FDA-approved adjuncts to cultures for diagnosing candidemia and other types of invasive candidiasis, but their clinical roles are unclear. In this chapter, we describe laboratory protocols for performing Fungitell and T2Candida assays. We then discuss step-by-step methods for interpreting test results at the bedside using a Bayesian framework, and for incorporating assays into rational patient management strategies. Prior to interpreting results, clinicians must recognize that test performance varies based on the type of invasive candidiasis being diagnosed. In general, the type of invasive candidiasis that is most likely in a given patient can be identified, and the pretest likelihood of disease estimated. From there, positive and negative predictive values (PPV, NPV) for an assay can be calculated. At a population level, tests can be incorporated into screening strategies for antifungal treatment. NPV and PPV thresholds can be defined for discontinuing antifungal prophylaxis or initiating preemptive treatment, respectively. Using the thresholds, it is possible to assign windows of pretest likelihood for invasive candidiasis (and corresponding patient populations) in which tests are most likely to valuable. At the individual patient level, tests may be useful outside of the windows proposed for screening populations. The interpretive and clinical decision-making processes we discuss will be applicable to other diagnostic assays as they enter the clinic, and to existing assays as more data emerge from various populations.

  13. The analysis of diagnostics possibilities of the Dual- Drive electric power steering system using diagnostics scanner and computer method

    NASA Astrophysics Data System (ADS)

    Szczypiński-Sala, W.; Dobaj, K.

    2016-09-01

    The article presents the analysis of diagnostics possibilities of electric power steering system using computer diagnostics scanner. Several testing attempts were performed. There were analyzed the changes of torque moment exerted on steering wheel by the driver and the changes of the angle of rotation steering wheel accompanying them. The tests were conducted in variable conditions comprising wheel load and the friction coefficient of tyre road interaction. Obtained results enabled the analysis of the influence of changeable operations conditions, possible to acquire in diagnostics scanners of chosen parameters of electric power steering system. Moreover, simulation model of operation, electric drive power steering system with the use of the Matlab simulation software was created. The results of the measurements obtained in road conditions served to verify this model. Subsequently, model response to inputs change of the device was analyzed and its reaction to various constructional and exploitative parameters was checked. The entirety of conducted work constitutes a step to create a diagnostic monitor possible to use in self-diagnosis of electric power steering system.

  14. FTDD973: A multimedia knowledge-based system and methodology for operator training and diagnostics

    NASA Technical Reports Server (NTRS)

    Hekmatpour, Amir; Brown, Gary; Brault, Randy; Bowen, Greg

    1993-01-01

    FTDD973 (973 Fabricator Training, Documentation, and Diagnostics) is an interactive multimedia knowledge based system and methodology for computer-aided training and certification of operators, as well as tool and process diagnostics in IBM's CMOS SGP fabrication line (building 973). FTDD973 is an example of what can be achieved with modern multimedia workstations. Knowledge-based systems, hypertext, hypergraphics, high resolution images, audio, motion video, and animation are technologies that in synergy can be far more useful than each by itself. FTDD973's modular and object-oriented architecture is also an example of how improvements in software engineering are finally making it possible to combine many software modules into one application. FTDD973 is developed in ExperMedia/2; and OS/2 multimedia expert system shell for domain experts.

  15. Diagnostic developments for quasicontinuous operation of the Wendelstein 7-X stellarator

    SciTech Connect

    Koenig, R.; Cantarini, J.; Dreier, H.; Erckmann, V.; Hildebrandt, D.; Hirsch, M.; Kornejew, P.; Laux, M.; Laqua, H.; Pasch, E.; Thomsen, H.; Weller, A.; Werner, A.; Wolf, R.; Ye, M. Y.; Kocsis, G.; Recsei, S.; Zoletnik, S.; Szabo, V.

    2008-10-15

    The stellarator Wendelstein 7-X will allow for quasicontinuous operation with the duration only being limited to two 30 min discharges per day, at a continuous heating power of 10 MW electron cyclotron resonance heating (ECRH) at 140 GHz, by the capacity of the cooling water reservoir. This will result in high thermal loads on all plasma facing components of 50-100 kW/m{sup 2} from radiation alone and of up to about 500 kW/m{sup 2} on components additionally exposed to convective loads. In high density scenarios toroidally varying ECRH stray radiation levels of 50-200 kW/m{sup 2} need to be coped with, requiring careful material selection and different shielding and hardening techniques. Furthermore, a gradual buildup of coatings on plasma facing optical components, which without any measures being taken, would lead to high transmission losses already within a few days of long pulse operation (equivalent to about 1 year of operation in pulsed devices like JET or ASDEX-upgrade) and therefore needs to be prevented as much as possible. In addition in situ cleaning as well as absolute calibration techniques need to be developed for all plasma facing optical systems. Here we report about some of our efforts to find, for various types of diagnostics, ways to cope with these adverse effects. Moreover, we give a few examples for individual diagnostic specific issues with respect to quasicontinuous operation, such as the development of a special integrator for the magnetic diagnostics as well as special interferometer types which can cope with unavoidable vibrations and slow path length changes due to, e.g., thermal expansion of the plasma vessel.

  16. Validation of the beam tracing method for heating and diagnostics

    SciTech Connect

    Maj, O.; Pereverzev, G. V.; Poli, E.

    2009-11-26

    The beam tracing approximate description of the propagation and absorption of wave beams is studied and compared to the corresponding exact solution of the wave equation for two simplified models relevant to electron cyclotron resonance heating and reflectometry diagnostics.

  17. Chronic intraoral pain--assessment of diagnostic methods and prognosis.

    PubMed

    Pigg, Maria

    2011-01-01

    The overall goal of this thesis was to broaden our knowledge of chronic intraoral pain. The research questions were: What methods can be used to differentiate inflammatory, odontogenic tooth pain from pain that presents as toothache but is non-odontogenic in origin? What is the prognosis of chronic tooth pain of non-odontogenic origin, and which factors affect the prognosis? Atypical odontalgia (AO) is a relatively rare but severe and chronic pain condition affecting the dentoalveolar region. Recent research indicates that the origin is peripheral nerve damage: neuropathic pain. The condition presents as tooth pain and is challenging to dentists because it is difficult to distinguish from ordinary toothache due to inflammation or infection. AO is of interest to the pain community because it shares many characteristics with other chronic pain conditions, and pain perpetuation mechanisms are likely to be similar. An AO diagnosis is made after a comprehensive examination and assessment of patients' self-reported characteristics: the pain history. Traditional dental diagnostic methods do not appear to suffice, since many patients report repeated care-seeking and numerous treatment efforts with little or no pain relief. Developing methods that are useful in the clinical setting is a prerequisite for a correct diagnosis and adequate treatment decisions. Quantitative sensory testing (QST) is used to assess sensory function on skin when nerve damage or disease is suspected. A variety of stimuli has been used to examine the perception of, for example, touch, temperature (painful and non-painful), vibration, pinprick pain, and pressure pain. To detect sensory abnormalities and nerve damage in the oral cavity, the same methods may be possible to use. Study I examined properties of thermal thresholds in and around the mouth in 30 pain-free subjects: the influence of measurement location and stimulation area size on threshold levels, and time variability of thresholds

  18. Optical caries diagnostics: comparison of laser spectroscopic PNC method with method of laser integral fluorescence

    NASA Astrophysics Data System (ADS)

    Masychev, Victor I.

    2000-11-01

    In this research we present the results of approbation of two methods of optical caries diagnostics: PNC-spectral diagnostics and caries detection by laser integral fluorescence. The research was conducted in a dental clinic. PNC-method analyses parameters of probing laser radiation and PNC-spectrums of stimulated secondary radiations: backscattering and endogenous fluorescence of caries-involved bacterias. He-Ne-laser ((lambda) =632,8 nm, 1-2mW) was used as a source of probing (stimulated) radiation. For registration of signals, received from intact and pathological teeth PDA-detector was applied. PNC-spectrums were processed by special algorithms, and were displayed on PC monitor. The method of laser integral fluorescence was used for comparison. In this case integral power of fluorescence of human teeth was measured. As a source of probing (stimulated) radiation diode lasers ((lambda) =655 nm, 0.1 mW and 630nm, 1mW) and He-Ne laser were applied. For registration of signals Si-photodetector was used. Integral power was shown in a digital indicator. Advantages and disadvantages of these methods are described in this research. It is disclosed that the method of laser integral power of fluorescence has the following characteristics: simplicity of construction and schema-technical decisions. However the method of PNC-spectral diagnostics are characterized by considerably more sensitivity in diagnostics of initial caries and capability to differentiate pathologies of various stages (for example, calculus/initial caries). Estimation of spectral characteristics of PNC-signals allows eliminating a number of drawbacks, which are character for detection by method of laser integral fluorescence (for instance, detection of fluorescent fillings, plagues, calculus, discolorations generally, amalgam, gold fillings as if it were caries.

  19. Advanced Optical Diagnostic Methods for Describing Fuel Injection and Combustion Flowfield Phenomena

    NASA Technical Reports Server (NTRS)

    Locke, Randy J.; Hicks, Yolanda R.; Anderson, Robert C.

    2004-01-01

    Over the past decade advanced optical diagnostic techniques have evolved and matured to a point where they are now widely applied in the interrogation of high pressure combusting flows. At NASA Glenn Research Center (GRC), imaging techniques have been used successfully in on-going work to develop the next generation of commercial aircraft gas turbine combustors. This work has centered on providing a means by which researchers and designers can obtain direct visual observation and measurements of the fuel injection/mixing/combustion processes and combustor flowfield in two- and three-dimensional views at actual operational conditions. Obtaining a thorough understanding of the chemical and physical processes at the extreme operating conditions of the next generation of combustors is critical to reducing emissions and increasing fuel efficiency. To accomplish this and other tasks, the diagnostic team at GRC has designed and constructed optically accessible, high pressurer high temperature flame tubes and sectar rigs capable of optically probing the 20-60 atm flowfields of these aero-combustors. Among the techniques employed at GRC are planar laser-induced fluorescence (PLIF) for imaging molecular species as well as liquid and gaseous fuel; planar light scattering (PLS) for imaging fuel sprays and droplets; and spontaneous Raman scattering for species and temperature measurement. Using these techniques, optical measurements never before possible have been made in the actual environments of liquid fueled gas turbines. 2-D mapping of such parameters as species (e.g. OH-, NO and kerosene-based jet fuel) distribution, injector spray angle, and fuel/air distribution are just some of the measurements that are now routinely made. Optical imaging has also provided prompt feedback to researchers regarding the effects of changes in the fuel injector configuration on both combustor performance and flowfield character. Several injector design modifications and improvements have

  20. A Comparison Between Two Methods for Display of Programmed Diagnostic Tests.

    ERIC Educational Resources Information Center

    Graham, Peter

    Two methods for presentation of programed diagnostic tests were compared. One method used a five-screen, tape and slide format and the other used television in the form of videotape recording. The electronics course used for the study employed 10 diagnostic tests, five for each method. Evaluation was made on the basis of test scores and attitude…

  1. An Analysis of Categorical Definitions, Diagnostic Methods, Diagnostic Criteria and Personnel Utilization in the Classification of Handicapped Children.

    ERIC Educational Resources Information Center

    Newkirk, Diane; And Others

    The project report provides information relevant to the status, function, and effect of currently used definitions of handicapped children and the diagnostic methods used. An initial section serves as both an introduction to and summary of the process used during the project, and includes project conclusions. Section II contains analyses of…

  2. Thermoelectric generator apparatus and operation method

    SciTech Connect

    Lowther, F.E.

    1984-07-31

    A method of operating a thermoelectric generator includes: cyclically producing increasing then decreasing temperature differences in the thermoelectric material of the generator; and generating a cyclically increasing then decreasing electrical generator output signal, in response to such temperature differences, to transmit electrical power generated by the generator from the generator. Part of the thermoelectric material reaches temperatures substantially above the melting temperature of the material. The thermoelectric material of the generator forms a part of a closed electrical loop about a transformer core so that the inductor voltage for the loop serves as the output signal of the generator. A thermoelectric generator, which can be driven by the described method of operation, incorporates fins into a thermopile to conduct heat toward or away from the alternating spaces between adjacent layers of different types of thermoelectric material. The fins extend from between adjacent layers, so that they can also conduct electrical current between such layers, perpendicularly to the direction of stacking of the layers. The exhaust from an internal combustion engine can be employed to drive the thermoelectric generator, and, also, to act as a driver for a thermoelectric generator in accordance with the method of operation initially described.

  3. First operations with the new Collective Thomson Scattering diagnostic on the Frascati Tokamak Upgrade device

    NASA Astrophysics Data System (ADS)

    Bin, W.; Bruschi, A.; D'Arcangelo, O.; Castaldo, C.; De Angeli, M.; Figini, L.; Galperti, C.; Garavaglia, S.; Granucci, G.; Grosso, G.; Korsholm, S. B.; Lontano, M.; Mellera, V.; Minelli, D.; Moro, A.; Nardone, A.; Nielsen, S. K.; Rasmussen, J.; Simonetto, A.; Stejner, M.; Tartari, U.

    2015-10-01

    Anomalous emissions were found over the last few years in spectra of Collective Thomson Scattering (CTS) diagnostics in tokamak devices such as TEXTOR, ASDEX and FTU, in addition to real CTS signals. The signal frequency, down-shifted with respect to the probing one, suggested a possible origin in Parametric Decay Instability (PDI) processes correlated with the presence of magnetic islands and occurring for pumping wave power levels well below the threshold predicted by conventional models. A threshold below or close to the Electron Cyclotron Resonance Heating (ECRH) power levels could limit, under certain circumstances, the use of the ECRH in fusion devices. An accurate characterization of the conditions for the occurrence of this phenomenon and of its consequences is thus of primary importance. Exploiting the front-steering configuration available with the real-time launcher, the implementation of a new CTS setup now allows studying these anomalous emission phenomena in FTU under conditions of density and wave injection geometry that are more similar to those envisaged for CTS in ITER. The upgrades of the diagnostic are presented as well as a few preliminary spectra detected with the new system during the very first operations in 2014. The present work has been carried out under an EUROfusion Enabling Research project. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  4. Evaluating Operational Specifications of Point-of-Care Diagnostic Tests: A Standardized Scorecard

    PubMed Central

    Lehe, Jonathan D.; Sitoe, Nádia E.; Tobaiwa, Ocean; Loquiha, Osvaldo; Quevedo, Jorge I.; Peter, Trevor F.; Jani, Ilesh V.

    2012-01-01

    The expansion of HIV antiretroviral therapy into decentralized rural settings will increasingly require simple point-of-care (POC) diagnostic tests that can be used without laboratory infrastructure and technical skills. New POC test devices are becoming available but decisions around which technologies to deploy may be biased without systematic assessment of their suitability for decentralized healthcare settings. To address this, we developed a standardized, quantitative scorecard tool to objectively evaluate the operational characteristics of POC diagnostic devices. The tool scores devices on a scale of 1–5 across 30 weighted characteristics such as ease of use, quality control, electrical requirements, shelf life, portability, cost and service, and provides a cumulative score that ranks products against a set of ideal POC characteristics. The scorecard was tested on 19 devices for POC CD4 T-lymphocyte cell counting, clinical chemistry or hematology testing. Single and multi-parameter devices were assessed in each of test categories. The scores across all devices ranged from 2.78 to 4.40 out of 5. The tool effectively ranked devices within each category (p<0.01) except the CD4 and multi-parameter hematology products. The tool also enabled comparison of different characteristics between products. Agreement across the four scorers for each product was high (intra-class correlation >0.80; p<0.001). Use of this tool enables the systematic evaluation of diagnostic tests to facilitate product selection and investment in appropriate technology. It is particularly relevant for countries and testing programs considering the adoption of new POC diagnostic tests. PMID:23118871

  5. Comparison of Self-Instruction Methods for Teaching Diagnostic Testing.

    ERIC Educational Resources Information Center

    Puskas, Jane C.

    1991-01-01

    Self-teaching booklets and computer media were evaluated for teaching diagnostic testing with first (n=49), second (n=41) and third year (n=71) dental students as a foundation for further development of clinical decision-making skills. Results found the media more effective than no instruction and equally effective to the traditional lecture…

  6. Sherlock Holmes' methods of deductive reasoning applied to medical diagnostics.

    PubMed

    Miller, L

    1985-03-01

    Having patterned the character of Sherlock Holmes after one of his professors, Sir Arthur Conan Doyle, himself a physician, incorporated many of the didactic qualities of the 19th century medical diagnostician into the character of Holmes. In this paper I explore Holmes's techniques of deductive reasoning and their basis in 19th and 20th century medical diagnostics.

  7. Electrically heated particulate filter diagnostic systems and methods

    DOEpatents

    Gonze, Eugene V [Pinckney, MI

    2009-09-29

    A system that diagnoses regeneration of an electrically heated particulate filter is provided. The system generally includes a grid module that diagnoses a fault of the grid based on at least one of a current signal and a voltage signal. A diagnostic module at least one of sets a fault status and generates a warning signal based on the fault of the grid.

  8. Engine and method for operating an engine

    DOEpatents

    Lauper, Jr., John Christian; Willi, Martin Leo; Thirunavukarasu, Balamurugesh; Gong, Weidong

    2008-12-23

    A method of operating an engine is provided. The method may include supplying a combustible combination of reactants to a combustion chamber of the engine, which may include supplying a first hydrocarbon fuel, hydrogen fuel, and a second hydrocarbon fuel to the combustion chamber. Supplying the second hydrocarbon fuel to the combustion chamber may include at least one of supplying at least a portion of the second hydrocarbon fuel from an outlet port that discharges into an intake system of the engine and supplying at least a portion of the second hydrocarbon fuel from an outlet port that discharges into the combustion chamber. Additionally, the method may include combusting the combustible combination of reactants in the combustion chamber.

  9. In Depth Diagnostics for RF System Operation in the PEP-II B Factory

    SciTech Connect

    Van Winkle, Daniel; Fox, John; Teytelman, Dmitry; /SLAC

    2005-05-27

    The PEP-II RF systems incorporate numerous feedback loops in the low-level processing for impedance control and operating point regulation. The interaction of the multiple loops with the beam is complicated, and the systems incorporate online diagnostic tools to configure the feedback loops as well as to record fault files in the case of an RF abort. Rapid and consistent analysis of the RF-related beam aborts and other failures is critical to the reliable operation of the B-Factory, especially at the recently achieved high beam currents. Procedures and algorithms used to extract diagnostic information from time domain fault files are presented and illustrated via example interpretations of PEP-II fault file data. Example faults presented will highlight the subtle interpretation required to determine the root cause. Some such examples are: abort kicker firing asynchronously, klystron and cavity arcs, beam loss leading to longitudinal instability, tuner read back jumps and poorly configured low-level RF feedback loop.

  10. In-situ diagnostic tools for hydrogen transfer leak characterization in PEM fuel cell stacks part II: Operational applications

    NASA Astrophysics Data System (ADS)

    Niroumand, Amir M.; Homayouni, Hooman; DeVaal, Jake; Golnaraghi, Farid; Kjeang, Erik

    2016-08-01

    This paper describes a diagnostic tool for in-situ characterization of the rate and distribution of hydrogen transfer leaks in Polymer Electrolyte Membrane (PEM) fuel cell stacks. The method is based on reducing the air flow rate from a high to low value at a fixed current, while maintaining an anode overpressure. At high air flow rates, the reduction in air flow results in lower oxygen concentration in the cathode and therefore reduction in cell voltages. Once the air flow rate in each cell reaches a low value at which the cell oxygen-starves, the voltage of the corresponding cell drops to zero. However, oxygen starvation results from two processes: 1) the electrochemical oxygen reduction reaction which produces current; and 2) the chemical reaction between oxygen and the crossed over hydrogen. In this work, a diagnostic technique has been developed that accounts for the effect of the electrochemical reaction on cell voltage to identify the hydrogen leak rate and number of leaky cells in a fuel cell stack. This technique is suitable for leak characterization during fuel cell operation, as it only requires stack air flow and voltage measurements, which are readily available in an operational fuel cell system.

  11. First hydrogen operation of NIO1: Characterization of the source plasma by means of an optical emission spectroscopy diagnostic.

    PubMed

    Barbisan, M; Baltador, C; Zaniol, B; Cavenago, M; Fantz, U; Pasqualotto, R; Serianni, G; Vialetto, L; Wünderlich, D

    2016-02-01

    NIO1 (Negative Ion Optimization 1) is a compact and flexible radio frequency H(-) ion source, developed by Consorzio RFX and INFN-LNL. The aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances, an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study, respectively, the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular, the sudden increase of the light emitted from the plasma above a certain power threshold. PMID:26932047

  12. Impact of gene patents on diagnostic testing: a new patent landscaping method applied to spinocerebellar ataxia

    PubMed Central

    Berthels, Nele; Matthijs, Gert; Van Overwalle, Geertrui

    2011-01-01

    Recent reports in Europe and the United States raise concern about the potential negative impact of gene patents on the freedom to operate of diagnosticians and on the access of patients to genetic diagnostic services. Patents, historically seen as legal instruments to trigger innovation, could cause undesired side effects in the public health domain. Clear empirical evidence on the alleged hindering effect of gene patents is still scarce. We therefore developed a patent categorization method to determine which gene patents could indeed be problematic. The method is applied to patents relevant for genetic testing of spinocerebellar ataxia (SCA). The SCA test is probably the most widely used DNA test in (adult) neurology, as well as one of the most challenging due to the heterogeneity of the disease. Typically tested as a gene panel covering the five common SCA subtypes, we show that the patenting of SCA genes and testing methods and the associated licensing conditions could have far-reaching consequences on legitimate access to this gene panel. Moreover, with genetic testing being increasingly standardized, simply ignoring patents is unlikely to hold out indefinitely. This paper aims to differentiate among so-called ‘gene patents' by lifting out the truly problematic ones. In doing so, awareness is raised among all stakeholders in the genetic diagnostics field who are not necessarily familiar with the ins and outs of patenting and licensing. PMID:21811306

  13. Multiple frequency method for operating electrochemical sensors

    SciTech Connect

    Martin, Louis P.

    2012-05-15

    A multiple frequency method for the operation of a sensor to measure a parameter of interest using calibration information including the steps of exciting the sensor at a first frequency providing a first sensor response, exciting the sensor at a second frequency providing a second sensor response, using the second sensor response at the second frequency and the calibration information to produce a calculated concentration of the interfering parameters, using the first sensor response at the first frequency, the calculated concentration of the interfering parameters, and the calibration information to measure the parameter of interest.

  14. [THE METHODICAL APPROACHES TO DIAGNOSTIC OF NIGHT PAROXYSMAL HEMOGLOBINURIA].

    PubMed

    Plekhanova, O S; Naumova, E V; Lugovskaya, S A; Potchtar, M E; Bugrov, I Yu; Dolgov, V V

    2016-03-01

    The article presents diagnostic of night paroxysmal hemoglobinuria. The night paroxysmal hemoglobinuria is an orphan disease characterized by absence of GPI-anchor on blood cells as a result of mutation of PIG-A gene on the short arm of X-chromosome. The particular proteins bounded with GPI-anchor implement function of defense from activation of components of complement and development of membrane-attacking complex. The erythrocytes exposed to destruction in bloodstream are among the most impacted. Therefore, one of the main signs of night paroxysmal hemoglobinuria is complement-depending intravascular hemolysis which indicators for a long time played a key role in diagnostic of night paroxysmal hemoglobinuria. The actual technique of diagnostic of night paroxysmal hemoglobinuria is flow cytometry. The analysis of night paroxysmal hemoglobinuria clone is recommended to patients with hemolysis of unclear genesis, thrombosis of cerebral and abdominal veins, thrombocytopenia and macrocytosis and also patients with AA, myelodysplastic syndrome, myelofibrosis. The international protocol recommended by the International Society of Clinical Cytometry (2010) is implemented to diagnose night paroxysmal hemoglobinuria. The original technique of evaluation of reticulocytes was developed with purpose to detect night paroxysmal hemoglobinuria clone. The high correlation was substantiated between size of night paroxysmal hemoglobinuria clone measured among reticulocytes according to proposed mode and night paroxysmal hemoglobinuria clone measured among granulocytes and monocytes detected according international standardized approach. PMID:27506106

  15. [THE METHODICAL APPROACHES TO DIAGNOSTIC OF NIGHT PAROXYSMAL HEMOGLOBINURIA].

    PubMed

    Plekhanova, O S; Naumova, E V; Lugovskaya, S A; Potchtar, M E; Bugrov, I Yu; Dolgov, V V

    2016-03-01

    The article presents diagnostic of night paroxysmal hemoglobinuria. The night paroxysmal hemoglobinuria is an orphan disease characterized by absence of GPI-anchor on blood cells as a result of mutation of PIG-A gene on the short arm of X-chromosome. The particular proteins bounded with GPI-anchor implement function of defense from activation of components of complement and development of membrane-attacking complex. The erythrocytes exposed to destruction in bloodstream are among the most impacted. Therefore, one of the main signs of night paroxysmal hemoglobinuria is complement-depending intravascular hemolysis which indicators for a long time played a key role in diagnostic of night paroxysmal hemoglobinuria. The actual technique of diagnostic of night paroxysmal hemoglobinuria is flow cytometry. The analysis of night paroxysmal hemoglobinuria clone is recommended to patients with hemolysis of unclear genesis, thrombosis of cerebral and abdominal veins, thrombocytopenia and macrocytosis and also patients with AA, myelodysplastic syndrome, myelofibrosis. The international protocol recommended by the International Society of Clinical Cytometry (2010) is implemented to diagnose night paroxysmal hemoglobinuria. The original technique of evaluation of reticulocytes was developed with purpose to detect night paroxysmal hemoglobinuria clone. The high correlation was substantiated between size of night paroxysmal hemoglobinuria clone measured among reticulocytes according to proposed mode and night paroxysmal hemoglobinuria clone measured among granulocytes and monocytes detected according international standardized approach.

  16. An objective method and measuring equipment for noise control and acoustic diagnostics of motorcars. [acoustic diagnostics on automobile engines

    NASA Technical Reports Server (NTRS)

    Kacprowski, J.; Motylewski, J.; Miazga, J.

    1974-01-01

    An objective method and apparatus for noise control and acoustic diagnostics of motorcar engines are reported. The method and apparatus let us know whether the noisiness of the vehicle under test exceeds the admissible threshold levels given by appropriate standards and if so what is the main source of the excessive noise. The method consists in measuring both the overall noise level and the sound pressure levels in definite frequency bands while the engine speed is controlled as well and may be fixed at prescribed values. Whenever the individually adjusted threshold level has been exceeded in any frequency band, a self-sustaining control signal is sent.

  17. Method matters: Understanding diagnostic reliability in DSM-IV and DSM-5.

    PubMed

    Chmielewski, Michael; Clark, Lee Anna; Bagby, R Michael; Watson, David

    2015-08-01

    Diagnostic reliability is essential for the science and practice of psychology, in part because reliability is necessary for validity. Recently, the DSM-5 field trials documented lower diagnostic reliability than past field trials and the general research literature, resulting in substantial criticism of the DSM-5 diagnostic criteria. Rather than indicating specific problems with DSM-5, however, the field trials may have revealed long-standing diagnostic issues that have been hidden due to a reliance on audio/video recordings for estimating reliability. We estimated the reliability of DSM-IV diagnoses using both the standard audio-recording method and the test-retest method used in the DSM-5 field trials, in which different clinicians conduct separate interviews. Psychiatric patients (N = 339) were diagnosed using the SCID-I/P; 218 were diagnosed a second time by an independent interviewer. Diagnostic reliability using the audio-recording method (N = 49) was "good" to "excellent" (M κ = .80) and comparable to the DSM-IV field trials estimates. Reliability using the test-retest method (N = 218) was "poor" to "fair" (M κ = .47) and similar to DSM-5 field-trials' estimates. Despite low test-retest diagnostic reliability, self-reported symptoms were highly stable. Moreover, there was no association between change in self-report and change in diagnostic status. These results demonstrate the influence of method on estimates of diagnostic reliability.

  18. Jet Noise Diagnostics Supporting Statistical Noise Prediction Methods

    NASA Technical Reports Server (NTRS)

    Bridges, James E.

    2006-01-01

    The primary focus of my presentation is the development of the jet noise prediction code JeNo with most examples coming from the experimental work that drove the theoretical development and validation. JeNo is a statistical jet noise prediction code, based upon the Lilley acoustic analogy. Our approach uses time-average 2-D or 3-D mean and turbulent statistics of the flow as input. The output is source distributions and spectral directivity. NASA has been investing in development of statistical jet noise prediction tools because these seem to fit the middle ground that allows enough flexibility and fidelity for jet noise source diagnostics while having reasonable computational requirements. These tools rely on Reynolds-averaged Navier-Stokes (RANS) computational fluid dynamics (CFD) solutions as input for computing far-field spectral directivity using an acoustic analogy. There are many ways acoustic analogies can be created, each with a series of assumptions and models, many often taken unknowingly. And the resulting prediction can be easily reverse-engineered by altering the models contained within. However, only an approach which is mathematically sound, with assumptions validated and modeled quantities checked against direct measurement will give consistently correct answers. Many quantities are modeled in acoustic analogies precisely because they have been impossible to measure or calculate, making this requirement a difficult task. The NASA team has spent considerable effort identifying all the assumptions and models used to take the Navier-Stokes equations to the point of a statistical calculation via an acoustic analogy very similar to that proposed by Lilley. Assumptions have been identified and experiments have been developed to test these assumptions. In some cases this has resulted in assumptions being changed. Beginning with the CFD used as input to the acoustic analogy, models for turbulence closure used in RANS CFD codes have been explored and

  19. The Revised Research Diagnostic Criteria for Temporomandibular Disorders: Methods used to Establish and Validate Revised Axis I Diagnostic Algorithms

    PubMed Central

    Schiffman, Eric L.; Ohrbach, Richard; Truelove, Edmond L.; Feng, Tai; Anderson, Gary C.; Pan, Wei; Gonzalez, Yoly M.; John, Mike T.; Sommers, Earl; List, Thomas; Velly, Ana M.; Kang, Wenjun; Look, John O.

    2011-01-01

    AIMS To derive reliable and valid revised Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms for clinical TMD diagnoses. METHODS The multi-site RDC/TMD Validation Project’s dataset (614 TMD community and clinic cases, and 91 controls) was used to derive revised algorithms for Axis I TMD diagnoses. Validity of diagnostic algorithms was assessed relative to reference standards, the latter based on consensus diagnoses rendered by 2 TMD experts using criterion examination data, including temporomandibular joint imaging. Cut-offs for target validity were sensitivity ≥ 0.70 and specificity ≥ 0.95. Reliability of revised algorithms was assessed in 27 study participants. RESULTS Revised algorithm sensitivity and specificity exceeded the target levels for myofascial pain (0.82, 0.99, respectively) and myofascial pain with limited opening (0.93, 0.97). Combining diagnoses for any myofascial pain showed sensitivity of 0.91 and specificity of 1.00. For joint pain, target sensitivity and specificity were observed (0.92, 0.96) when arthralgia and osteoarthritis were combined as “any joint pain.” Disc displacement without reduction with limited opening demonstrated target sensitivity and specificity (0.80, 0.97). For the other Group II disc displacements and Group III osteoarthritis and osteoarthrosis, sensitivity was below target (0.35 to 0.53), and specificity ranged from 0.80 to meeting target. Kappa for revised algorithm diagnostic reliability was ≥ 0.63. CONCLUSION Revised RDC/TMD Axis I TMD diagnostic algorithms are recommended for myofascial pain and joint pain as reliable and valid. However, revised clinical criteria alone, without recourse to imaging, are inadequate for valid diagnosis of two of the three disc displacements and osteoarthritis/osteoarthrosis. PMID:20213032

  20. Surveillance system and method having an operating mode partitioned fault classification model

    NASA Technical Reports Server (NTRS)

    Bickford, Randall L. (Inventor)

    2005-01-01

    A system and method which partitions a parameter estimation model, a fault detection model, and a fault classification model for a process surveillance scheme into two or more coordinated submodels together providing improved diagnostic decision making for at least one determined operating mode of an asset.

  1. Method of operating a coal gasifier

    DOEpatents

    Blaskowski, Henry J.

    1979-01-01

    A method of operating an entrained flow coal gasifier which comprises the steps of firing coal at two levels in a combustion zone with near stoichiometric air, removing molten ash from the combustion zone, conveying combustion products upwardly from the combustion zone through a reduction zone, injecting additional coal into the combustion products in the reduction zone and gasifying at least a portion of the coal to form low BTU gas, conveying the gas to a point of use, including also reducing gasifier output by modifying the ratio of air to coal supplied to the upper level of the combustion zone so that the ratio becomes increasingly substoichiometric thereby extending the gasification of coal from the reduction zone into the upper level of the combustion zone, and maintaining the lower level of coal in the combustion zone at near stoichiometric conditions so as to provide sufficient heat to maintain effective slagging conditions.

  2. Advanced diagnostic methods in oral and maxillofacial pathology. Part II: immunohistochemical and immunofluorescent methods.

    PubMed

    Jordan, Richard C K; Daniels, Troy E; Greenspan, John S; Regezi, Joseph A

    2002-01-01

    The practice of pathology is currently undergoing significant change, in large part due to advances in the analysis of DNA, RNA, and proteins in tissues. These advances have permitted improved biologic insights into many developmental, inflammatory, metabolic, infectious, and neoplastic diseases. Moreover, molecular analysis has also led to improvements in the accuracy of disease diagnosis and classification. It is likely that, in the future, these methods will increasingly enter into the day-to-day diagnosis and management of patients. The pathologist will continue to play a fundamental role in diagnosis and will likely be in a pivotal position to guide the implementation and interpretation of these tests as they move from the research laboratory into diagnostic pathology. The purpose of this 2-part series is to provide an overview of the principles and applications of current molecular biologic and immunologic tests. In Part I, the biologic fundamentals of DNA, RNA, and proteins and methods that are currently available or likely to become available to the pathologist in the next several years for their isolation and analysis in tissue biopsies were discussed. In Part II, advances in immunohistochemistry and immunofluorescence methods and their application to modern diagnostic pathology are reviewed. PMID:11805778

  3. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    SciTech Connect

    Corey, J.P.; Liudahl, J.J.; Young, S.A.; Rodman, S.M. )

    1991-03-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician.

  4. Increasing role of arthropod bites in tularaemia transmission in Poland - case reports and diagnostic methods.

    PubMed

    Formińska, Kamila; Zasada, Aleksandra A; Rastawicki, Waldemar; Śmietańska, Karolina; Bander, Dorota; Wawrzynowicz-Syczewska, Marta; Yanushevych, Mariya; Niścigórska-Olsen, Jolanta; Wawszczak, Marek

    2015-01-01

    The study describes four cases of tularaemia - one developed after contact with rabbits and three developed after an arthropod bite. Due to non-specific clinical symptoms, accurate diagnosis of tularaemia may be difficult. The increasing contribution of the arthropod vectors in the transmission of the disease indicates that special effort should be made to apply sensitive and specific diagnostic methods for tularaemia, and to remind health-care workers about this route of Francisella tularensis infections. The advantages and disadvantages of various diagnostic methods - molecular, serological and microbiological culture - are discussed. The PCR as a rapid and proper diagnostic method for ulceroglandular tularaemia is presented.

  5. Non-Intrusive Optical Diagnostic Methods for Flowfield Characterization

    NASA Technical Reports Server (NTRS)

    Tabibi, Bagher M.; Terrell, Charles A.; Spraggins, Darrell; Lee, Ja. H.; Weinstein, Leonard M.

    1997-01-01

    Non-intrusive optical diagnostic techniques such as Electron Beam Fluorescence (EBF), Laser-Induced Fluorescence (LIF), and Focusing Schlieren (FS) have been setup for high-speed flow characterization and large flowfield visualization, respectively. Fluorescence emission from the First Negative band of N2(+) with the (0,0) vibration transition (at lambda =391.44 nm) was obtained using the EBF technique and a quenching rate of N2(+)* molecules by argon gas was reported. A very high sensitivity FS system was built and applied in the High-Speed Flow Generator (HFG) at NASA LaRC. A LIF system is available at the Advanced Propulsion Laboratory (APL) on campus and a plume exhaust velocity measurement, measuring the Doppler shift from lambda = 728.7 nm of argon gas, is under way.

  6. The Rapid-Heat LAMPellet Method: A Potential Diagnostic Method for Human Urogenital Schistosomiasis

    PubMed Central

    Carranza-Rodríguez, Cristina; Pérez-Arellano, José Luis; Vicente, Belén; López-Abán, Julio; Muro, Antonio

    2015-01-01

    Background Urogenital schistosomiasis due to Schistosoma haematobium is a serious underestimated public health problem affecting 112 million people - particularly in sub-Saharan Africa. Microscopic examination of urine samples to detect parasite eggs still remains as definitive diagnosis. This work was focussed on developing a novel loop-mediated isothermal amplification (LAMP) assay for detection of S. haematobium DNA in human urine samples as a high-throughput, simple, accurate and affordable diagnostic tool to use in diagnosis of urogenital schistosomiasis. Methodology/Principal Findings A LAMP assay targeting a species specific sequence of S. haematobium ribosomal intergenic spacer was designed. The effectiveness of our LAMP was assessed in a number of patients´ urine samples with microscopy confirmed S. haematobium infection. For potentially large-scale application in field conditions, different DNA extraction methods, including a commercial kit, a modified NaOH extraction method and a rapid heating method were tested using small volumes of urine fractions (whole urine, supernatants and pellets). The heating of pellets from clinical samples was the most efficient method to obtain good-quality DNA detectable by LAMP. The detection limit of our LAMP was 1 fg/µL of S. haematobium DNA in urine samples. When testing all patients´ urine samples included in our study, diagnostic parameters for sensitivity and specificity were calculated for LAMP assay, 100% sensitivity (95% CI: 81.32%-100%) and 86.67% specificity (95% CI: 75.40%-94.05%), and also for microscopy detection of eggs in urine samples, 69.23% sensitivity (95% CI: 48.21% -85.63%) and 100% specificity (95% CI: 93.08%-100%). Conclusions/Significance We have developed and evaluated, for the first time, a LAMP assay for detection of S. haematobium DNA in heated pellets from patients´ urine samples using no complicated requirement procedure for DNA extraction. The procedure has been named the Rapid

  7. Spectrophotometric Method for Differentiation of Human Skin Melanoma. II. Diagnostic Characteristics

    NASA Astrophysics Data System (ADS)

    Petruk, V. G.; Ivanov, A. P.; Kvaternyuk, S. M.; Barunb, V. V.

    2016-05-01

    Experimental data on the spectral dependences of the optical diffuse reflection coefficient for skin from different people with melanoma or nevus are presented in the form of the probability density of the diffuse reflection coefficient for the corresponding pigmented lesions. We propose a noninvasive technique for differentiating between malignant and benign tumors, based on measuring the diffuse reflection coefficient for a specific patient and comparing the value obtained with a pre-set threshold. If the experimental result is below the threshold, then it is concluded that the person has melanoma; otherwise, no melanoma is present. As an example, we consider the wavelength 870 nm. We determine the risk of malignant transformation of a nevus (its transition to melanoma) for different measured diffuse reflection coefficients. We have studied the errors in the method, its operating characteristics and probability characteristics as the threshold diffuse reflection coefficient is varied. We find that the diagnostic confidence, sensitivity, specificity, and effectiveness (accuracy) parameters are maximum (>0.82) for a threshold of 0.45-0.47. The operating characteristics for the proposed technique exceed the corresponding parameters for other familiar optical approaches to melanoma diagnosis. Its distinguishing feature is operation at only one wavelength, and consequently implementation of the experimental technique is simplified and made less expensive.

  8. Hydroxymethyl phosphine compounds for use as diagnostic and therapeutic pharmaceuticals and method of making same

    SciTech Connect

    Katti, K.V.; Karra, S.R.; Berning, D.E.; Smith, C.J.; Volkert, W.A.; Ketring, A.R.

    2000-04-25

    A compound and method of making a compound for use as a diagnostic or therapeutic pharmaceutical comprises at least one functionalized hydroxyalkyl phosphine donor group and one or more sulfur or nitrogen donor and a metal combined with the ligand.

  9. Hydroxymethyl phosphine compounds for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, Kattesh V.; Karra, Srinivasa Rao; Berning, Douglas E.; Smith, C. Jeffrey; Volkert, Wynn A.; Ketring, Alan R.

    2000-01-01

    A compound and method of making a compound for use as a diagnostic or therapeutic pharmaceutical comprises at least one functionalized hydroxyalkyl phosphine donor group and one or more sulfur or nitrogen donor and a metal combined with the ligand.

  10. Hydroxymethyl phosphine compounds for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, Kattesh V.; Karra, Srinivasa Rao; Berning, Douglas E.; Smith, C. Jeffrey; Volkert, Wynn A.; Ketring, Alan R.

    1999-01-01

    A compound and method of making a compound for use as a diagnostic or therapeutic pharmaceutical comprises at least one functionalized hydroxyalkyl phosphine donor group and one or more sulfur or nitrogen donor and a metal combined with the ligand.

  11. Method of operating a neutronic reactor

    DOEpatents

    Woods, Wallace K.

    1976-05-25

    1. A method of operating a reactor having an active portion of a given length between a charging end and a discharging end, a first end region of the reactor extending from the charging end for one-quarter to one-third of said given length, a second end region extending from the discharging end for one-quarter to one-third of said given length, and a middle region extending between said end regions, said method comprising the steps of inserting end to end in the active region through the charging end a first group of bodies filling the middle region and a second group of bodies filling the first end region, irradiating the first and second groups of bodies while in the middle and first end regions, removing the first group from the reactor through the second end region, shifting the second group through the middle region to the second end region, inserting new first and second groups of bodies through the charging face into the middle and first end regions of the reactor, respectively, and irradiating the original second group and the new first and second groups while in the second end, middle, and first end regions, respectively, removing the original second group and the new first group from the reactor through the second end region, shifting the new second group through the middle region to the second end region, and irradiating the new second group again, whereby the first groups of bodies are irradiated only once and the second groups are irradiated twice.

  12. Diagnostic accuracy and receiver-operating characteristics curve analysis in surgical research and decision making.

    PubMed

    Søreide, Kjetil; Kørner, Hartwig; Søreide, Jon Arne

    2011-01-01

    In surgical research, the ability to correctly classify one type of condition or specific outcome from another is of great importance for variables influencing clinical decision making. Receiver-operating characteristic (ROC) curve analysis is a useful tool in assessing the diagnostic accuracy of any variable with a continuous spectrum of results. In order to rule a disease state in or out with a given test, the test results are usually binary, with arbitrarily chosen cut-offs for defining disease versus health, or for grading of disease severity. In the postgenomic era, the translation from bench-to-bedside of biomarkers in various tissues and body fluids requires appropriate tools for analysis. In contrast to predetermining a cut-off value to define disease, the advantages of applying ROC analysis include the ability to test diagnostic accuracy across the entire range of variable scores and test outcomes. In addition, ROC analysis can easily examine visual and statistical comparisons across tests or scores. ROC is also favored because it is thought to be independent from the prevalence of the condition under investigation. ROC analysis is used in various surgical settings and across disciplines, including cancer research, biomarker assessment, imaging evaluation, and assessment of risk scores.With appropriate use, ROC curves may help identify the most appropriate cutoff value for clinical and surgical decision making and avoid confounding effects seen with subjective ratings. ROC curve results should always be put in perspective, because a good classifier does not guarantee the expected clinical outcome. In this review, we discuss the fundamental roles, suggested presentation, potential biases, and interpretation of ROC analysis in surgical research.

  13. Frequency-Domain Methods for Characterization of Pulsed Power Diagnostics

    SciTech Connect

    White, A D; Anderson, R A; Ferriera, T J; Goerz, D A

    2009-07-27

    This paper discusses methods of frequency-domain characterization of pulsed power sensors using vector network analyzer and spectrum analyzer techniques that offer significant simplification over time-domain methods, while mitigating or minimizing the effect of the difficulties present in time domain characterization. These methods are applicable to characterization of a wide variety of sensors.

  14. Wavelet and multiscale methods for operator equations

    NASA Astrophysics Data System (ADS)

    Dahmen, Wolfgang

    More than anything else, the increase of computing power seems to stimulate the greed for tackling ever larger problems involving large-scale numerical simulation. As a consequence, the need for understanding something like the intrinsic complexity of a problem occupies a more and more pivotal position. Moreover, computability often only becomes feasible if an algorithm can be found that is asymptotically optimal. This means that storage and the number of floating point operations needed to resolve the problem with desired accuracy remain proportional to the problem size when the resolution of the discretization is refined. A significant reduction of complexity is indeed often possible, when the underlying problem admits a continuous model in terms of differential or integral equations. The physical phenomena behind such a model usually exhibit characteristic features over a wide range of scales. Accordingly, the most successful numerical schemes exploit in one way or another the interaction of different scales of discretization. A very prominent representative is the multigrid methodology; see, for instance, Hackbusch (1985) and Bramble (1993). In a way it has caused a breakthrough in numerical analysis since, in an important range of cases, it does indeed provide asymptotically optimal schemes. For closely related multilevel techniques and a unified treatment of several variants, such as multiplicative or additive subspace correction methods, see Bramble, Pasciak and Xu (1990), Oswald (1994), Xu (1992), and Yserentant (1993). Although there remain many unresolved problems, multigrid or multilevel schemes in the classical framework of finite difference and finite element discretizations exhibit by now a comparatively clear profile. They are particularly powerful for elliptic and parabolic problems.

  15. Diagnostic methods and treatment modalities of dry eye conditions.

    PubMed

    Holly, F J

    1993-06-01

    One may view dry eye conditions as a group of diseases in which the ocular surface is adversely affected. Tear film instability invariably leads to some degree of cellular surface damage over the cornea and conjunctiva. In turn, ocular epitheliopathy may adversely affect tear film stability. The clinical presentation of the disease may not yield a clue as to its etiology. In recent years considerable progress was made both in the diagnosis and the treatment of the disease and promising studies are planned or are underway. The diagnostic techniques can be divided into four groups. The first is concerned with the clinical presentation. The second is concerned with the bulk properties of the aqueous tears including dynamic characteristics, composition, and colligative properties. The third is tear-film related and includes the film break-up time, evaporation rate, and lipid abnormality. The fourth is concerned with the ocular surface and includes vital staining, impression cytology, and surface microscopy. The most promising attempts are being made in the second group by attempting to elucidate the role of enzyme and enzyme activator activity and inhibitor contents as well as the tear protein profiles and correlating them with the specific disease states. The treatment modalities belong to three major groups aside from surgical intervention; the supplementation, preservation, and the stimulation of tears. The modern version of tear supplementation is expected to include the topical use of efficacious aqueous formulations that typically contain film stabilizing polymers, nutrients, and/or--in the future--biochemically active ingredients such as enzyme activators and inhibitors.

  16. Tokamak physics studies using x-ray diagnostic methods

    SciTech Connect

    Hill, K.W.; Bitter, M.; von Goeler, S.; Beiersdorfer, P.; Fredrickson, E.; Hsuan, H.; McGuire, K.; Sauthoff, N.R.; Sesnic, S.; Stevens, J.E.

    1987-03-01

    X-ray diagnostic measurements have been used in a number of experiments to improve our understanding of important tokamak physics issues. The impurity content in TFTR plasmas, its sources and control have been clarified through soft x-ray pulse-height analysis (PHA) measurements. The dependence of intrinsic impurity concentrations and Z/sub eff/ on electron density, plasma current, limiter material and conditioning, and neutral-beam power have shown that the limiter is an important source of metal impurities. Neoclassical-like impurity peaking following hydrogen pellet injection into Alcator C and a strong effect of impurities on sawtooth behavior were demonstrated by x-ray imaging (XIS) measurements. Rapid inward motion of impurities and continuation of m = 1 activity following an internal disruption were demonstrated with XIS measurements on PLT using injected aluminum to enhance the signals. Ion temperatures up to 12 keV and a toroidal plasma rotation velocity up to 6 x 10/sup 5/ m/s have been measured by an x-ray crystal spectrometer (XCS) with up to 13 MW of 85-keV neutral-beam injection in TFTR. Precise wavelengths and relative intensities of x-ray lines in several helium-like ions and neon-like ions of silver have been measured in TFTR and PLT by the XCS. The data help to identify the important excitation processes predicted in atomic physics. Wavelengths of n = 3 to 2 silver lines of interest for x-ray lasers were measured, and precise instrument calibration techniques were developed. Electron thermal conductivity and sawtooth dynamics have been studied through XIS measurements on TFTR of heat-pulse propagation and compound sawteeth. A non-Maxwellian electron distribution function has been measured, and evidence of the Parail-Pogutse instability identified by hard x-ray PHA measurements on PLT during lower-hybrid current-drive experiments.

  17. A Simplified Diagnostic Method for Elastomer Bond Durability

    NASA Technical Reports Server (NTRS)

    White, Paul

    2009-01-01

    A simplified method has been developed for determining bond durability under exposure to water or high humidity conditions. It uses a small number of test specimens with relatively short times of water exposure at elevated temperature. The method is also gravimetric; the only equipment being required is an oven, specimen jars, and a conventional laboratory balance.

  18. New drilling/operating methods boost efficiency

    SciTech Connect

    Not Available

    1994-03-01

    The industry has not had viable alternatives for solving several major operating problems in areas of downhole and surface drilling operations, and facility and equipment maintenance. However, recent introductions and proven application of innovative problem solving techniques have removed these dilemmas for many operators. Four such technology advances are shown here. These include: (1) novel, clear protectors and compound that allow visual pipe thread inspection, (2) foam-core insulation for preserving Arctic ice drill pads, (3) a mobile system for producing multiple stripper wells, (4) a tool to retrieve data from a stuck logging recorder, and (5) a complete surface/downhole slimhole drilling system.

  19. Analysis method for Thomson scattering diagnostics in GAMMA 10/PDX

    NASA Astrophysics Data System (ADS)

    Ohta, K.; Yoshikawa, M.; Yasuhara, R.; Chikatsu, M.; Shima, Y.; Kohagura, J.; Sakamoto, M.; Nakasima, Y.; Imai, T.; Ichimura, M.; Yamada, I.; Funaba, H.; Minami, T.

    2016-11-01

    We have developed an analysis method to improve the accuracies of electron temperature measurement by employing a fitting technique for the raw Thomson scattering (TS) signals. Least square fitting of the raw TS signals enabled reduction of the error in the electron temperature measurement. We applied the analysis method to a multi-pass (MP) TS system. Because the interval between the MPTS signals is very short, it is difficult to separately analyze each Thomson scattering signal intensity by using the raw signals. We used the fitting method to obtain the original TS scattering signals from the measured raw MPTS signals to obtain the electron temperatures in each pass.

  20. A diagnostic method that uses causal knowledge and linear programming in the application of Bayes' formula.

    PubMed

    Cooper, G F

    1986-04-01

    Bayes' formula has been applied extensively in computer-based medical diagnostic systems. One assumption that is often made in the application of the formula is that the findings in a case are conditionally independent. This assumption is often invalid and leads to inaccurate posterior probability assignments to the diagnostic hypotheses. This paper discusses a method for using causal knowledge to structure findings according to their probabilistic dependencies. An inference procedure is discussed which propagates probabilities within a network of causally related findings in order to calculate posterior probabilities of diagnostic hypotheses. A linear programming technique is described that bounds the values of the propagated probabilities subject to known probabilistic constraints.

  1. [Unconventional diagnostic and therapeutic methods in environmental medicine].

    PubMed

    Oepen, I

    1998-07-01

    In the sphere of environmental medicine--analogous to other fields like oncology and chronic diseases--not only proven and approved methods, but also unconvential methods are offered, without evidence of efficacy. The application of these methods has the possible consequence of wrong diagnosis and malpractice. Examples are discussed such as Kirlian photography, electroacupuncture according to Voll, bioresonance diagnosis/therapy, kinesiology, regulation therapy according to Rost, "clinical ecology" according to Runow with, among others, the provocation/neutralisation test, a vaccination therapy with E. coli and finally electrosmog as an environmental noxa. Concerning the admissibility of contested methods, statements of medical specialist societies, judgements, and the law of medical products are quoted. In conclusion, the question of the origin of the ideas and alleged results of unconvential medicine is followed up and conclusions are drawn. PMID:9738351

  2. Operator Influence on Blinded Diagnostic Accuracy of Point-of-Care Antigen Testing for Group A Streptococcal Pharyngitis.

    PubMed

    Penney, Carla; Porter, Robert; O'Brien, Mary; Daley, Peter

    2016-01-01

    Background. Acute pharyngitis caused by Group A Streptococcus (GAS) is a common presentation to pediatric emergency departments (ED). Diagnosis with conventional throat culture requires 18-24 hours, which prevents point-of-care treatment decisions. Rapid antigen detection tests (RADT) are faster, but previous reports demonstrate significant operator influence on performance. Objective. To measure operator influence on the diagnostic accuracy of a RADT when performed by pediatric ED nurses and clinical microbiology laboratory technologists, using conventional culture as the reference standard. Methods. Children presenting to a pediatric ED with suspected acute pharyngitis were recruited. Three pharyngeal swabs were collected at once. One swab was used to perform the RADT in the ED, and two were sent to the clinical microbiology laboratory for RADT and conventional culture testing. Results. The RADT when performed by technologists compared to nurses had a 5.1% increased sensitivity (81.4% versus 76.3%) (p = 0.791) (95% CI for difference between technologists and nurses = -11% to +21%) but similar specificity (97.7% versus 96.6%). Conclusion. The performance of the RADT was similar between technologists and ED nurses, although adequate power was not achieved. RADT may be employed in the ED without clinically significant loss of sensitivity. PMID:27579047

  3. Operator Influence on Blinded Diagnostic Accuracy of Point-of-Care Antigen Testing for Group A Streptococcal Pharyngitis

    PubMed Central

    O'Brien, Mary

    2016-01-01

    Background. Acute pharyngitis caused by Group A Streptococcus (GAS) is a common presentation to pediatric emergency departments (ED). Diagnosis with conventional throat culture requires 18–24 hours, which prevents point-of-care treatment decisions. Rapid antigen detection tests (RADT) are faster, but previous reports demonstrate significant operator influence on performance. Objective. To measure operator influence on the diagnostic accuracy of a RADT when performed by pediatric ED nurses and clinical microbiology laboratory technologists, using conventional culture as the reference standard. Methods. Children presenting to a pediatric ED with suspected acute pharyngitis were recruited. Three pharyngeal swabs were collected at once. One swab was used to perform the RADT in the ED, and two were sent to the clinical microbiology laboratory for RADT and conventional culture testing. Results. The RADT when performed by technologists compared to nurses had a 5.1% increased sensitivity (81.4% versus 76.3%) (p = 0.791) (95% CI for difference between technologists and nurses = −11% to +21%) but similar specificity (97.7% versus 96.6%). Conclusion. The performance of the RADT was similar between technologists and ED nurses, although adequate power was not achieved. RADT may be employed in the ED without clinically significant loss of sensitivity. PMID:27579047

  4. Restrictive Stochastic Item Selection Methods in Cognitive Diagnostic Computerized Adaptive Testing

    ERIC Educational Resources Information Center

    Wang, Chun; Chang, Hua-Hua; Huebner, Alan

    2011-01-01

    This paper proposes two new item selection methods for cognitive diagnostic computerized adaptive testing: the restrictive progressive method and the restrictive threshold method. They are built upon the posterior weighted Kullback-Leibler (KL) information index but include additional stochastic components either in the item selection index or in…

  5. Application of optical flow method for imaging diagnostic in JET

    NASA Astrophysics Data System (ADS)

    Craciunescu, T.; Murari, A.; Alonso, A.; Lang, P. T.; Kocsis, G.; Tiseanu, I.; Zoita, V.; JET EFDA Contributors

    2010-05-01

    An optical flow method is applied to the study of several fusion plasma relevant issues, including plasma wall interactions. A multi-resolution coarse-to-fine procedure is used in order to cope with large displacements of objects between consecutive frames, characteristic of plasma images captured by JET fast visible camera. Occlusion modeling is also implemented. The method is able to provide good results for JET fast visible camera images which can be affected by saturation, discontinuous movement, reshaping of image objects, low gray-level in-depth resolution. Significant experimental cases concerning pellet injection, plasma filaments and MARFEs are analysed. The method is able to provide the real velocity for objects moving close to structures.

  6. Optical methods for diagnostic of cell-tissue grafts

    NASA Astrophysics Data System (ADS)

    Timchenko, P. E.; Timchenko, E. V.; Volova, L. T.; Boltovskaya, V. V.; Zherdeva, L. A.; Belousov, N. V.; Pershutkina, S. V.

    2015-08-01

    In this work the results of cell-tissue grafts research with a complex of optical methods - confocal fluorescent microscopy and Raman spectroscopy are presented. It was established that coefficient M scatter is related to irregularity of demineralization process. It was microscopically shown that the quantity of integrated cells into these types of transplants amounts to 20% of its surface.

  7. Calreticulin Mutations in Myeloproliferative Neoplasms: Comparison of Three Diagnostic Methods

    PubMed Central

    Park, Ji-Hye; Sevin, Margaux; Ramla, Selim; Truffot, Aurélie; Verrier, Tiffany; Bouchot, Dominique; Courtois, Martine; Bas, Mathilde; Benali, Sonia; Bailly, François; Favre, Bernardine; Guy, Julien; Martin, Laurent; Maynadié, Marc; Carillo, Serge; Girodon, François

    2015-01-01

    Calreticulin (CALR) mutations have recently been reported in 70–84% of JAK2V617F-negative myeloproliferative neoplasms (MPN), and this detection has become necessary to improve the diagnosis of MPN. In a large single-centre cohort of 298 patients suffering from Essential Thrombocythemia (ET), the JAK2V617F, CALR and MPL mutations were noted in 179 (60%), 56 (18.5%) and 13 (4.5%) respectively. For the detection of the CALR mutations, three methods were compared in parallel: high-resolution melting-curve analysis (HRM), product-sizing analysis and Sanger sequencing. The sensitivity for the HRM, product-sizing analysis and Sanger sequencing was 96.4%, 98.2% and 89.3% respectively, whereas the specificity was 96.3%, 100% and 100%. In our cohort, the product-sizing analysis was the most sensitive method and was the easiest to interpret, while the HRM was sometimes difficult to interpret. In contrast, when large series of samples were tested, HRM provided results more quickly than did the other methods, which required more time. Finally, the sequencing method, which is the reference method, had the lowest sensitivity but can be used to describe the type of mutation precisely. Altogether, our results suggest that in routine laboratory practice, product-sizing analysis is globally similar to HRM for the detection of CALR mutations, and that both may be used as first-line screening tests. If the results are positive, Sanger sequencing can be used to confirm the mutation and to determine its type. Product-sizing analysis provides sensitive and specific results, moreover, with the quantitative measurement of CALR, which might be useful to monitor specific treatments. PMID:26501981

  8. Stably operating pulse combustor and method

    DOEpatents

    Zinn, B.T.; Reiner, D.

    1990-05-29

    A pulse combustor apparatus is described which is adapted to burn either a liquid fuel or a pulverized solid fuel within a preselected volume of the combustion chamber. The combustion process is substantially restricted to an optimum combustion zone in order to attain effective pulse combustion operation. 4 figs.

  9. Stably operating pulse combustor and method

    DOEpatents

    Zinn, Ben T.; Reiner, David

    1990-01-01

    A pulse combustor apparatus adapted to burn either a liquid fuel or a pulverized solid fuel within a preselected volume of the combustion chamber. The combustion process is substantially restricted to an optimum combustion zone in order to attain effective pulse combustion operation.

  10. Control Methods of Operational Properties of Lubricants

    NASA Astrophysics Data System (ADS)

    Lysyannikova, N.; Kovalski, B.; Bezborodov, Yu; Lysyannikov, A.; Kravtsova, Ye; Shram, V.; Kovaleva, M.

    2016-06-01

    Some results of thermal-oxidation and temperature stability testing of motor oils are presented. The catalytic influence of metals on oxidizing processes in lubricants with use of steel 45 was determined. The parameters for identification of oils by groups of operational properties and quantity indicators of the influence of metals on oxidizing processes of lubricants are offered.

  11. Fraley's syndrome: case report and update on current diagnostic methods

    SciTech Connect

    Zuckier, L.S.; Patel, Y.D.; Fine, E.J.; Koenigsberg, M.

    1988-01-01

    A 38-year-old woman presented with fever, right flank pain, and a clinical diagnosis of pyelonephritis. Work-up revealed the presence of a crossing arterial branch causing obstruction of the superior infundibulum of the right kidney, which is an uncommon cause of nephralgia and urinary infection initially described by Fraley in 1966. Intravenous urography, retrograde pyelography, and angiography remain the mainstay of diagnosis, much as in the initial descriptions of this entity. (/sup 131/I)Hippuran imaging, with analysis of the upper and lower pole regions of interest, provides a simple yet powerful method of evaluating functional and excretory changes in the superior infundibulum, and has proved more efficacious than previously reported whole-kidney renograms. Renal scintigraphy represents a relatively noninvasive method of serial functional examination in this disorder. Ultrasound imaging, by monitoring upper-pole dilatation, may provide complementary morphologic information important for long-term follow-up.

  12. Multiple light scattering methods for multiphase flow diagnostics

    NASA Astrophysics Data System (ADS)

    Estevadeordal, Jordi

    2015-11-01

    Multiphase flows of gases and liquids containing droplets, bubbles, or particulates present light scattering imaging challenges due to the interference from each phase, such as secondary reflections, extinctions, absorptions, and refractions. These factors often prevent the unambiguous detection of each phase and also produce undesired beam steering. The effects can be especially complex in presence of dense phases, multispecies flows, and high pressure environments. This investigation reports new methods for overcoming these effects for quantitative measurements of velocity, density, and temperature fields. The methods are based on light scattering techniques combining Mie and filtered Rayleigh scattering and light extinction analyses and measurements. The optical layout is designed to perform multiple property measurements with improved signal from each phase via laser spectral and polarization characterization, etalon decontamination, and use of multiple wavelengths and imaging detectors.

  13. Apparatus and method for monitoring breath acetone and diabetic diagnostics

    DOEpatents

    Duan, Yixiang; Cao, Wenqing

    2008-08-26

    An apparatus and method for monitoring diabetes through breath acetone detection and quantitation employs a microplasma source in combination with a spectrometer. The microplasma source provides sufficient energy to produce excited acetone fragments from the breath gas that emit light. The emitted light is sent to the spectrometer, which generates an emission spectrum that is used to detect and quantify acetone in the breath gas.

  14. Diagnostic of the surface micro-discharge using spectroscopic methods

    NASA Astrophysics Data System (ADS)

    Li, Yang-Fang; Morfill, Gregor

    2012-10-01

    A handheld and battery-driven CAP device is designed for clinical studies. The accomplished medical phase I study has shown high bactericidal efficacy in vitro, ex vivo as well as in vivo. Although tests have been done concerning the biological safety and toxic gas emissions accordingly to the electrical safety, the chemical production of this device is not well addressed. In particular, the ozone production remains to be a big issue for safety reasons and reactive Nitrogen and Oxygen species (RNOS) are regarded to the key players for the biological and medical effects of CAPs. Given the application time for the clinical trial would be in the range of 30 seconds, we will present the temporal evolution of several RNOS within running time of a few minutes. The measurement is done mainly by the optical emission and absorption spectroscopies. Depending on the characteristic parameters of the applied voltage signal for discharge, the production of the RNOS may evolve in different profiles. Especially for high power operation, the discharge takes around 30 seconds to reach a steady state. Although the discharge power is found to be the most important factor, the characteristic frequency and even the gas temperature in ambient air, which in our case is the working gas, may alter the yields of several species, for example ozone and atomic Oxygen. The result will help for developing CAP devices for different applications and to design the protocol for the clinical test concerning the efficacy and safety.

  15. Design predictions and diagnostic test methods for hydronic heating systems in ASHRAE standard 152P

    SciTech Connect

    Andrews, J.W.

    1996-04-01

    A new method of test for residential thermal distribution efficiency is currently being developed under the auspices of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). The initial version of this test method is expected to have two main approaches, or ``pathways,`` designated Design and Diagnostic. The Design Pathway will use builder`s information to predict thermal distribution efficiency in new construction. The Diagnostic Pathway will use simple tests to evaluate thermal distribution efficiency in a completed house. Both forced-air and hydronic systems are included in the test method. This report describes an approach to predicting and measuring thermal distribution efficiency for residential hydronic heating systems for use in the Design and Diagnostic Pathways of the test method. As written, it is designed for single-loop systems with any type of passive radiation/convection (baseboard or radiators). Multiloop capability may be added later.

  16. A new method with general diagnostic utility for the calculation of immunoglobulin G avidity.

    PubMed

    Korhonen, M H; Brunstein, J; Haario, H; Katnikov, A; Rescaldani, R; Hedman, K

    1999-09-01

    The reference method for immunoglobulin G (IgG) avidity determination includes reagent-consuming serum titration. Aiming at better IgG avidity diagnostics, we applied a logistic model for the reproduction of antibody titration curves. This method was tested with well-characterized serum panels for cytomegalovirus, Epstein-Barr virus, rubella virus, parvovirus B19, and Toxoplasma gondii. This approach for IgG avidity calculation is generally applicable and attains the diagnostic performance of the reference method while being less laborious and twice as cost-effective.

  17. Diagnostic imaging methods applied in long-term surveillance after EVAR. Will computed tomography angiography be replaced by other methods?

    PubMed Central

    Stefaniak, Karolina; Gabriel, Marcin; Oszkinis, Grzegorz

    2016-01-01

    Endovascular implantation of a stent graft in the abdominal aorta (endovascular aneurysm repair – EVAR) is a widely accepted alternative to open surgery in treatment of abdominal aortic aneurysms. Although EVAR is connected with a significant reduction in the risk of peri- and post-operative complications, it does not eliminate them totally. Long-term surveillance of post-EVAR patients is aimed at early detection of and fast reaction to a group of complications called endovascular leaks. Currently, the gold standard in leak diagnostics is computed tomography angiography (CTA). The other methods are ultrasonography, magnetic resonance (MR) angiography, intra-aneurysm sac pressure measurement, X-ray, and digital subtraction angiography (DSA). Despite many analyses based on long-term research, emphasising the high value and competitiveness of less invasive tests such as US or X-ray compared to CTA, it is still difficult for them to win the trust and acceptance of clinicians. The persisting view is that computed tomography is the test that finally resolves any inaccuracies. Consequently, a patient with a number of concurrent diseases is subject to absurdly high radiation exposure and effects of a radiocontrast agent within a short time. It is therefore logical to acknowledge that the EVAR-related risk is catching up with the open surgery risk, while the endovascular procedure is much more costly. Nevertheless, the status of CTA as the gold standard ultimately seems to be unthreatened. This paper presents a description of the diagnostic imaging tests that make it possible to detect any vascular leaks and to develop strategies for therapeutic processes. PMID:26966443

  18. Making Diagnostic Inferences about Cognitive Attributes Using the Rule-Space Model and Attribute Hierarchy Method

    ERIC Educational Resources Information Center

    Gierl, Mark J.

    2007-01-01

    The purpose of this paper is to describe the logic and identify key assumptions associated with making cognitive inferences using two attribute-based psychometric methods. The first method is Kikumi Tatsuoka's rule-space model. This model provides a strong point of reference for studying the nature of diagnostic inferences because it is important…

  19. Using the Attribute Hierarchy Method to Make Diagnostic Inferences about Examinees' Cognitive Skills in Critical Reading

    ERIC Educational Resources Information Center

    Wang, Changjiang; Gierl, Mark J.

    2011-01-01

    The purpose of this study is to apply the attribute hierarchy method (AHM) to a subset of SAT critical reading items and illustrate how the method can be used to promote cognitive diagnostic inferences. The AHM is a psychometric procedure for classifying examinees' test item responses into a set of attribute mastery patterns associated with…

  20. Thomson scattering as a method for laser plasma diagnostics

    SciTech Connect

    Alayi, Y.

    1983-12-01

    The Thomson scattering has been used to determine the density and temperature of an inhomogeneous nonstationary plasma. A common method to calibrate the Thomson scattering device consists in replacing the plasma by a gas and measuring the Rayleigh scattering cross section. The angular distribution of the scattered light in Argon is measured, the incident light is a ruby laser with ..delta..t = 30ns and lambda = 6943nm and vertically polarized. We have found that angular distribution is strongly favored in the forward direction (30/sup 0/, 45/sup 0/, 60/sup 0/) and defavored for backward direction (90/sup 0/, 120/sup 0/, 135/sup 0/, 150/sup 0/) in agreement with the results of George, et al, but in disagreement with the Rayleigh theory which assumes a uniform distribution. Our results may be related to the form of the scattered light spectrum which undergoes a dramatic change through the kinetic-hydrodynamic transition. The general form of the spectrum is determined by the parameter y = 1/Kl (where K = 4..pi.. sin (theta/2)/lambda, theta is the scattering angle and l is the free path path), which increases in the direction of the hydrodynamic regime (small angles). By analogy, the Thomson scattering presents the same aspects with ..cap alpha.. = 1/Klambda /SUB D/ (where lambda /SUB D/ is the Debye length). The deviation from the uniform distribution provides the possibility to determine the plasma turbulence spectrum from the scattered light.

  1. Agile Development Methods for Space Operations

    NASA Technical Reports Server (NTRS)

    Trimble, Jay; Webster, Chris

    2012-01-01

    Main stream industry software development practice has gone from a traditional waterfall process to agile iterative development that allows for fast response to customer inputs and produces higher quality software at lower cost. How can we, the space ops community, adopt state of the art software development practice, achieve greater productivity at lower cost, and maintain safe and effective space flight operations? At NASA Ames, we are developing Mission Control Technologies Software, in collaboration with Johnson Space Center (JSC) and, more recently, the Jet Propulsion Laboratory (JPL).

  2. Characterization and diagnostic methods for geomagnetic auroral infrasound waves

    NASA Astrophysics Data System (ADS)

    Oldham, Justin J.

    Infrasonic perturbations resulting from auroral activity have been observed since the 1950's. In the last decade advances in infrasonic microphone sensitivity, high latitude sensor coverage, time series analysis methods and computational efficiency have elucidated new types of auroral infrasound. Persistent periods of infrasonic activity associated with geomagnetic sub-storms have been termed geomagnetic auroral infrasound waves [GAIW]. We consider 63 GAIW events recorded by the Fairbanks, AK infrasonic array I53US ranging from 2003 to 2014 and encompassing a complete solar cycle. We make observations of the acoustic features of these events alongside magnetometer, riometer, and all-sky camera data in an effort to quantify the ionospheric conditions suitable for infrasound generation. We find that, on average, the generation mechanism for GAIW is confined to a region centered about ~60 0 longitude east of the anti-Sun-Earth line and at ~770 North latitude. We note furthermore that in all cases considered wherein imaging riometer data are available, that dynamic regions of heightened ionospheric conductivity periodically cross the overhead zenith. Consistent features in concurrent magnetometer conditions are also noted, with irregular oscillations in the horizontal component of the field ubiquitous in all cases. In an effort to produce ionosphere based infrasound free from the clutter and unknowns typical of geophysical observations, an experiment was undertaken at the High Frequency Active Auroral Research Program [HAARP] facility in 2012. Infrasonic signals appearing to originate from a source region overhead were observed briefly on 9 August 2012. The signals were observed during a period when an electrojet current was presumed to have passed overhead and while the facilities radio transmitter was periodically heating the lower ionosphere. Our results suggest dynamic auroral electrojet currents as primary sources of much of the observed infrasound, with

  3. Zenker’s diverticulum: aetiopathogenesis, symptoms and diagnosis. Comparison of operative methods

    PubMed Central

    Nehring, Piotr

    2013-01-01

    Zenker’s diverticulum is an alimentary tract pouch localized in the area of the upper esophageal sphincter. Treatment procedure complications and coexisting diseases constitute a serious diagnostic and therapeutic problem. Characteristic symptoms and signs facilitate differential diagnosis, simultaneously being real patient maladies. There are many treatment procedures leading to pouch septum reduction and decrease of upper esophageal sphincter pressure. After years of experience in operating and endoscopic treatments we found it necessary to compare these different methods. PMID:24868270

  4. Relevance of the choice of diagnostic methods to investigate laser damage resistance in optical material

    NASA Astrophysics Data System (ADS)

    Natoli, Jean-Yves; Wagner, Frank; Gallais, Laurent; Commandré, Mireille

    2012-01-01

    Laser induced damage in optical material in nanosecond regime is widely attributed to local precursors in range of nanometer to micrometer size. The damage precursors nature strongly depends on materials (coatings, non linear crystals, substrates,..), breakdown location (bulk, surface, interface) and irradiation parameters (wavelength, pulse duration...). The weakness of knowledge on parameters as sizes, densities and natures of precursors, let think that the choice of the diagnostic method which reveals laser damage has to be adapted to each situation of irradiation. Concerning the LIDT determination, destructive methods are usually involved: we can cite full size test using the "real" final configuration of irradiation, raster scan method using a focused laser beam allowing laboratory test and statistic approach allowing study with different beam sizes in order to probe the material homogeneity in terms of precursors. This multi-scale approaches give relevant information on material properties regarding high power laser irradiation. In order to investigate the laser damage initiation mechanisms, it appears necessary to involve non-destructive diagnostics. These diagnostics permit to highlight modifications linked to precursors before material breakdown. The main difficulty here is the local character of the diagnostic added to the low density of initiating center. A multi-scale approach is thus also well adapted to the non-destructive case. Interest of diagnostics as local fluorescence and photothermal deflexion both correlated with LIDT results will be discussed. To illustrate the purpose, examples on non linear crystals and coatings will be shown.

  5. Relevance of the choice of diagnostic methods to investigate laser damage resistance in optical material

    NASA Astrophysics Data System (ADS)

    Natoli, Jean-Yves; Wagner, Frank; Gallais, Laurent; Commandré, Mireille

    2011-11-01

    Laser induced damage in optical material in nanosecond regime is widely attributed to local precursors in range of nanometer to micrometer size. The damage precursors nature strongly depends on materials (coatings, non linear crystals, substrates,..), breakdown location (bulk, surface, interface) and irradiation parameters (wavelength, pulse duration...). The weakness of knowledge on parameters as sizes, densities and natures of precursors, let think that the choice of the diagnostic method which reveals laser damage has to be adapted to each situation of irradiation. Concerning the LIDT determination, destructive methods are usually involved: we can cite full size test using the "real" final configuration of irradiation, raster scan method using a focused laser beam allowing laboratory test and statistic approach allowing study with different beam sizes in order to probe the material homogeneity in terms of precursors. This multi-scale approaches give relevant information on material properties regarding high power laser irradiation. In order to investigate the laser damage initiation mechanisms, it appears necessary to involve non-destructive diagnostics. These diagnostics permit to highlight modifications linked to precursors before material breakdown. The main difficulty here is the local character of the diagnostic added to the low density of initiating center. A multi-scale approach is thus also well adapted to the non-destructive case. Interest of diagnostics as local fluorescence and photothermal deflexion both correlated with LIDT results will be discussed. To illustrate the purpose, examples on non linear crystals and coatings will be shown.

  6. Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

    PubMed Central

    Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin

    2016-01-01

    Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority.

  7. Diagnostic methods for assessing maxillary skeletal and dental transverse deficiencies: A systematic review

    PubMed Central

    Sawchuk, Dena; Currie, Kris; Vich, Manuel Lagravere; Palomo, Juan Martin

    2016-01-01

    Objective To evaluate the accuracy and reliability of the diagnostic tools available for assessing maxillary transverse deficiencies. Methods An electronic search of three databases was performed from their date of establishment to April 2015, with manual searching of reference lists of relevant articles. Articles were considered for inclusion if they reported the accuracy or reliability of a diagnostic method or evaluation technique for maxillary transverse dimensions in mixed or permanent dentitions. Risk of bias was assessed in the included articles, using the Quality Assessment of Diagnostic Accuracy Studies tool-2. Results Nine articles were selected. The studies were heterogeneous, with moderate to low methodological quality, and all had a high risk of bias. Four suggested that the use of arch width prediction indices with dental cast measurements is unreliable for use in diagnosis. Frontal cephalograms derived from cone-beam computed tomography (CBCT) images were reportedly more reliable for assessing intermaxillary transverse discrepancies than posteroanterior cephalograms. Two studies proposed new three-dimensional transverse analyses with CBCT images that were reportedly reliable, but have not been validated for clinical sensitivity or specificity. No studies reported sensitivity, specificity, positive or negative predictive values or likelihood ratios, or ROC curves of the methods for the diagnosis of transverse deficiencies. Conclusions Current evidence does not enable solid conclusions to be drawn, owing to a lack of reliable high quality diagnostic studies evaluating maxillary transverse deficiencies. CBCT images are reportedly more reliable for diagnosis, but further validation is required to confirm CBCT's accuracy and diagnostic superiority. PMID:27668196

  8. New method of acne disease fluorescent diagnostics in natural and fluorescent light and treatment control

    NASA Astrophysics Data System (ADS)

    Karimova, L. N.; Berezin, A. N.; Shevchik, S. A.; Kharnas, S. S.; Kusmin, S. G.; Loschenov, V. B.

    2005-08-01

    In the given research the new method of fluorescent diagnostics (FD) and photodynamic therapy (PDT) control of acne disease is submitted. Method is based on simultaneous diagnostics in natural and fluorescent light. PDT was based on using 5-ALA (5- aminolevulinic acid) preparation and 600-730 nanometers radiation. If the examined site of a skin possessed a high endogenous porphyrin fluorescence level, PDT was carried out without 5-ALA. For FD and treatment control a dot spectroscopy and the fluorescent imaging of the affected skin were used.

  9. Hydrogasification reactor and method of operating same

    DOEpatents

    Hobbs, Raymond; Karner, Donald; Sun, Xiaolei; Boyle, John; Noguchi, Fuyuki

    2013-09-10

    The present invention provides a system and method for evaluating effects of process parameters on hydrogasification processes. The system includes a hydrogasification reactor, a pressurized feed system, a hopper system, a hydrogen gas source, and a carrier gas source. Pressurized carbonaceous material, such as coal, is fed to the reactor using the carrier gas and reacted with hydrogen to produce natural gas.

  10. Optical Diagnostic Characterization of High-Power Hall Thruster Wear and Operation

    NASA Technical Reports Server (NTRS)

    Williams, George J., Jr.; Soulas, George C.; Kamhawi, Hani

    2012-01-01

    Optical emission spectroscopy is employed to correlate BN insulator erosion with high-power Hall thruster operation. Specifically, actinometry leveraging excited xenon states is used to normalize the emission spectra of ground state boron as a function of thruster operating condition. Trends in the strength of the boron signal are correlated with thruster power, discharge voltage, and discharge current. In addition, the technique is demonstrated on metallic coupons embedded in the walls of the HiVHAc EM thruster. The OES technique captured the overall trend in the erosion of the coupons which boosts credibility in the method since there are no data to which to calibrate the erosion rates of high-power Hall thrusters. The boron signals are shown to trend linearly with discharge voltage for a fixed discharge current as expected. However, the boron signals of the higher-power NASA 300M and NASA 457Mv2 trend with discharge current and show an unexpectedly weak to inverse dependence on discharge voltage. Electron temperatures measured optically in the near-field plume of the thruster agree well with Langmuir probe data. However, the optical technique used to determine Te showed unacceptable sensitivity to the emission intensities. Near-field, single-frequency imaging of the xenon neutrals is also presented as a function of operating condition for the NASA 457 Mv2.

  11. [Methodical features of the molding of diagnostic competences in medical parasitology workers].

    PubMed

    Dovgalev, A S; Astanina, S Iu; Avdiukhina, T I; Serdiuk, A P; Imamkuliev, K D

    2015-01-01

    The paper provides a rationale for a procedure to mold diagnostic competences in medical workers of the laboratories of therapeutic-and-prophylactic institutions and hygiene and epidemiology centers, Russian Federal Service for Supervision of Consumer Rights Protection and Human Welfare. The methodical features of molding diagnostic competences in the above contingents are the design and organization of an educational process by applying systems integration and competence-based approaches; increased active self-directed learning of audience; a procedure to organize its unsupervised extracurricular activities. Professional habits and skills in laboratory specialists should be molded on the basis of didactic principles and in compliance with the found methodical patterns. The eventual result (molded competences) and its compliance with the practical health care requirements is assessed using all control types (incoming, running, intermediate, and ultimate ones). This ensures the stability and predictability of molding diagnostic competences in parasitology specialists.

  12. Hydroxymethyl phosphine compounds for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, K.V.; Karra, S.R.; Berning, D.E.; Smith, C.J.; Volkert, W.A.; Ketring, A.R.

    1999-01-05

    A compound and method of making a compound for use as a diagnostic or therapeutic pharmaceutical comprises at least one functionalized hydroxyalkyl phosphine donor group and one or more sulfur or nitrogen donor and a metal combined with the ligand. 21 figs.

  13. Hydroxyalkyl phosphine gold complexes for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, K.V.; Berning, D.E.; Volkert, W.A.; Ketring, A.R.

    1998-12-01

    A complex and method for making a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids. 20 figs.

  14. Hydroxyalkyl phosphine gold complexes for use as diagnostic and therapeutic pharmaceuticals and method of making same

    DOEpatents

    Katti, Kattesh V.; Berning, Douglas E.; Volkert, Wynn A.; Ketring, Alan R.

    1998-01-01

    A complex and method for making same for use as a diagnostic or therapeutic pharmaceutical includes a ligand comprising at least one hydroxyalkyl phosphine donor group bound to a gold atom to form a gold-ligand complex that is stable in aqueous solutions containing oxygen, serum and other body fluids.

  15. Depression and Spinal Cord Injury: A Review of Diagnostic Methods for Depression, 1985 to 2000.

    ERIC Educational Resources Information Center

    Skinner, Amy L.; Armstrong, Kevin J.; Rich, John

    2003-01-01

    Studies of depression in individuals with spinal cord injuries (SCI) over a 15-year period were examined to determine if researchers used consistent diagnostic measures. The Beck Depression Inventory was the most frequently used instrument, but there was inconsistency among methods employed and disagreement regarding the inclusion of somatic…

  16. [Perforated duodenal ulcer in a Roux-en-Y gastric bypass operated patient can be a diagnostic challenge].

    PubMed

    Wied, Christian; Akralið, Guðny B; Lauritsen, Morten Laksáfoss; Naver, Lars Peter Skat

    2013-02-25

    Roux-en-Y gastric bypass (RYGBP) is an increasingly used procedure when treating morbid obesity. Due to the extensive gastrointestinal rearrangement, diagnostic evaluation of patients with gastric bypass and acute abdominal pain can be difficult. We present a case of a perforated duodenal ulcer in a RYGBP operated patient, where free abdominal fluid, but hardly any pneumoperitoneum was seen on a computed tomography. Free intraperitoneal fluid is an important finding and should give suspicion of the need for emergency surgery in RYGBP operated patients with abdominal pain.

  17. Inhalation exposure systems: design, methods and operation.

    PubMed

    Wong, Brian A

    2007-01-01

    The respiratory system, the major route for entry of oxygen into the body, provides entry for external compounds, including pharmaceutic and toxic materials. These compounds (that might be inhaled under environmental, occupational, medical, or other situations) can be administered under controlled conditions during laboratory inhalation studies. Inhalation study results may be controlled or adversely affected by variability in four key factors: animal environment; exposure atmosphere; inhaled dose; and individual animal biological response. Three of these four factors can be managed through engineering processes. Variability in the animal environment is reduced by engineering control of temperature, humidity, oxygen content, waste gas content, and noise in the exposure facility. Exposure atmospheres are monitored and adjusted to assure a consistent and known exposure for each animal dose group. The inhaled dose, affected by changes in respiration physiology, may be controlled by exposure-specific monitoring of respiration. Selection of techniques and methods for the three factors affected by engineering allows the toxicologic pathologist to study the reproducibility of the fourth factor, the biological response of the animal. PMID:17325967

  18. Estimation of diagnostic test accuracy without full verification: a review of latent class methods

    PubMed Central

    Collins, John; Huynh, Minh

    2014-01-01

    The performance of a diagnostic test is best evaluated against a reference test that is without error. For many diseases, this is not possible, and an imperfect reference test must be used. However, diagnostic accuracy estimates may be biased if inaccurately verified status is used as the truth. Statistical models have been developed to handle this situation by treating disease as a latent variable. In this paper, we conduct a systematized review of statistical methods using latent class models for estimating test accuracy and disease prevalence in the absence of complete verification. PMID:24910172

  19. Diagnostics of PF-1000 Facility Operation and Plasma Concentration on the Basis of Spectral Measurements

    SciTech Connect

    Skladnik-Sadowska, E.; Malinowski, K.; Sadowski, M. J.; Scholz, M.; Tsarenko, A. V.

    2006-01-15

    The paper concerns the monitoring of high-current pulse discharges and the determination of the plasma concentration within the dense magnetized plasma by means of optical spectroscopy methods. In experiments with the large PF-1000 facility operated at IPPLM in Warsaw, Poland, attention was paid to the determination of the operational mode and electron concentration under different experimental conditions. To measure the visible radiation (VR) the use was made of the MECHELLE registered 900-spectrometer equipped with the CCD readout. The VR emission, observed at 65 deg. to the z-axis, originated from a part of the electrode surfaces, the collapsing current-sheath layer and the dense plasma pinch-region (40-50 mm from the electrode ends). Considerable differences were found in the optical spectra recorded for so-called 'good shots' and for cases of some failures. Estimates of the electron concentration, which were performed with different spectroscopic techniques, showed that it ranged from 5.56x1018 cm-3 to 4.8x1019 cm-3, depending on experimental conditions. The correlation of the fusion-neutron yield and the plasma density was proved.

  20. System and method of operating toroidal magnetic confinement devices

    DOEpatents

    Chance, M.S.; Jardin, S.C.; Stix, T.H.; Grimm, R.C.; Manickam, J.; Okabayashi, M.

    1984-08-30

    This invention pertains to methods and arrangements for attaining high beta values in plasma confinement devices. More specifically, this invention pertains to methods for accessing the second stability region of operation in toroidal magnetic confinement devices.

  1. A real-time PCR diagnostic method for detection of Naegleria fowleri.

    PubMed

    Madarová, Lucia; Trnková, Katarína; Feiková, Sona; Klement, Cyril; Obernauerová, Margita

    2010-09-01

    Naegleria fowleri is a free-living amoeba that can cause primary amoebic meningoencephalitis (PAM). While, traditional methods for diagnosing PAM still rely on culture, more current laboratory diagnoses exist based on conventional PCR methods; however, only a few real-time PCR processes have been described as yet. Here, we describe a real-time PCR-based diagnostic method using hybridization fluorescent labelled probes, with a LightCycler instrument and accompanying software (Roche), targeting the Naegleria fowleriMp2Cl5 gene sequence. Using this method, no cross reactivity with other tested epidemiologically relevant prokaryotic and eukaryotic organisms was found. The reaction detection limit was 1 copy of the Mp2Cl5 DNA sequence. This assay could become useful in the rapid laboratory diagnostic assessment of the presence or absence of Naegleria fowleri.

  2. Method for assessing motor insulation on operating motors

    DOEpatents

    Kueck, John D.; Otaduy, Pedro J.

    1997-01-01

    A method for monitoring the condition of electrical-motor-driven devices. The method is achieved by monitoring electrical variables associated with the functioning of an operating motor, applying these electrical variables to a three phase equivalent circuit and determining non-symmetrical faults in the operating motor based upon symmetrical components analysis techniques.

  3. Method for assessing motor insulation on operating motors

    DOEpatents

    Kueck, J.D.; Otaduy, P.J.

    1997-03-18

    A method for monitoring the condition of electrical-motor-driven devices is disclosed. The method is achieved by monitoring electrical variables associated with the functioning of an operating motor, applying these electrical variables to a three phase equivalent circuit and determining non-symmetrical faults in the operating motor based upon symmetrical components analysis techniques. 15 figs.

  4. Comparison of laser spectroscopic PNC method with laser integral fluorescence in optical caries diagnostics

    NASA Astrophysics Data System (ADS)

    Masychev, Victor I.

    2001-05-01

    In this research we represent the results of approbation of two methods of optical caries diagnostics: PNC-spectral diagnostics and caries detection by laser integral fluorescence. The research was conducted in a dental clinic. PNC-method analyzes parameters of probing laser radiation and PNC-spectrums of stimulated secondary radiations: backscattering and endogenous fluorescence of caries- involved bacteria. Ia-Ne laser ((lambda) equals632.8 nm, 1-2 mW) was used as a source of probing (stimulated) radiation. For registration of signals, received from intact and pathological teeth PDA-detector was applied. PNC-spectrums were processed by special algorithms, and were displayed on PC monitor. The method of laser integral fluorescence was used for comparison. In this case integral power of fluorescence of human teeth was measured. As a source of probing (stimulated) radiation diode lasers ((lambda) equals655 nm, 0.1 mW and 630 nm, 1 mW) and Ia-Na laser were applied. For registration of signals Si-photodetector was used. Integral power was shown in a digital indicator. Advantages and disadvantages of these methods are described in this research. It is disclosed that the method of laser integral power of fluorescence has the following characteristics: simplicity of construction and schema-technical decisions. However the method of PNC-spectral diagnostics are characterized by considerably more sensitivity in diagnostics of initial caries and capability to differentiate pathologies of various stages (for example, calculus/initial caries). Estimation of spectral characteristics of PNC-signals allows eliminating a number of drawbacks, which are character for detection by method of laser integral fluorescence (for instance, detection of fluorescent fillings, plagues, calculus, discolorations generally, amalgam, gold fillings as if it were caries).

  5. Instrumentation for noninvasive express-diagnostics bacteriophages and viruses by optical method

    NASA Astrophysics Data System (ADS)

    Moguilnaia, Tatiana A.; Andreev, Gleb I.; Agibalov, Andrey A.; Botikov, Andrey G.; Kosenkov, Evgeniy; Saguitova, Elena

    2004-03-01

    The theoretical and the experimental researches of spectra of absent-minded radiation in medium containing viruses were carried out. The information on spectra luminescence 31 viruses was written down.The new method the express - analysis of viruses in organism of the man was developed. It shall be mentioned that the proposed method of express diagnostics allows detection of infection agent in the organism several hours after infection. It makes it suitable for high efficient testing in blood services for detection and rejection of potential donors infected with such viruses as hepatitis, herpes, Epstein-Barre, cytomegalovirus, and immunodeficiency. Methods of serum diagnostics used for that purpose can detect antibodies to virus only 1-3 months after the person has been infected. The device for the express analysis of 31 viruses of the man was created.

  6. Development and improvement of the operating diagnostics systems of NPO CKTI works for turbine of thermal and nuclear power plants

    NASA Astrophysics Data System (ADS)

    Kovalev, I. A.; Rakovskii, V. G.; Isakov, N. Yu.; Sandovskii, A. V.

    2016-03-01

    The work results on the development and improvement of the techniques, algorithms, and software-hardware of continuous operating diagnostics systems of rotating units and parts of turbine equipment state are presented. In particular, to ensure the full remote service of monitored turbine equipment using web technologies, the web version of the software of the automated systems of vibration-based diagnostics (ASVD VIDAS) was developed. The experience in the automated analysis of data obtained by ASVD VIDAS form the basis of the new algorithm of early detection of such dangerous defects as rotor deflection, crack in the rotor, and strong misalignment of supports. The program-technical complex of monitoring and measuring the deflection of medium pressure rotor (PTC) realizing this algorithm will alert the electric power plant staff during a deflection and indicate its value. This will give the opportunity to take timely measures to prevent the further extension of the defect. Repeatedly, recorded cases of full or partial destruction of shrouded shelves of rotor blades of the last stages of low-pressure cylinders of steam turbines defined the need to develop a version of the automated system of blade diagnostics (ASBD SKALA) for shrouded stages. The processing, analysis, presentation, and backup of data characterizing the mechanical state of blade device are carried out with a newly developed controller of the diagnostics system. As a result of the implementation of the works, the diagnosed parameters determining the operation security of rotating elements of equipment was expanded and the new tasks on monitoring the state of units and parts of turbines were solved. All algorithmic solutions and hardware-software implementations mentioned in the article were tested on the test benches and applied at some power plants.

  7. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    SciTech Connect

    Winniford, Michael D

    2013-02-08

    smaller diameter catheters have both been shown to reduce the volume of contrast administered. The use of smaller size catheters also permits more rapid hemostasis, thus allowing shorter ambulation time without the need for costly wound closure devices. These factors can result in enhanced patient satisfaction as well as more efficient management of post-procedure rooms. The intent of this study was to demonstrate that using the MEDRAD Avanta Fluid Management Injection System (MEDRAD, INC., Pittsburgh, PA) for coronary diagnostic procedures can produce a reduction in the volume of contrast administered without loss of operational quality or efficiency. In addition, this study will explore procedure time and efficiency in an effort to minimize the amount of ionizing radiation delivered to the patient as well as the diagnostic team members. Study Design This is a post-market study designed to collect data during diagnostic cardiac catheterization when utilizing 5FR or 6FR catheters in conjunction with the Avanta Fluid Management System or a manual manifold injection method control group. A minimum of 420 patients scheduled for diagnostic cardiac catheterization will be enrolled in the study cohort. Patients will be assigned into the following two groups. Group 1: Catheterization with 5FR or 6FR catheters, using the traditional manual manifold injection method for contrast media delivery which is defined as manual hand injection of contrast media through a 3 or 4 port manifold and left ventriculography performed via standard fixed rate power injection. Group 2: Catheterization with 5FR or 6FR catheters, using the MEDRAD Avanta system for contrast media delivery. Study endpoints include volume of contrast media administered during diagnostic cardiac catheterization, volume of contrast media wasted post-procedure, procedure time (defined as the time from first catheter insertion to last diagnostic catheter removal), fluoroscopy time and angiographic image quality. The study

  8. Diagnostic utility of the cell block method versus the conventional smear study in pleural fluid cytology

    PubMed Central

    Shivakumarswamy, Udasimath; Arakeri, Surekha U; Karigowdar, Mahesh H; Yelikar, BR

    2012-01-01

    Background: The cytological examinations of serous effusions have been well-accepted, and a positive diagnosis is often considered as a definitive diagnosis. It helps in staging, prognosis and management of the patients in malignancies and also gives information about various inflammatory and non-inflammatory lesions. Diagnostic problems arise in everyday practice to differentiate reactive atypical mesothelial cells and malignant cells by the routine conventional smear (CS) method. Aims: To compare the morphological features of the CS method with those of the cell block (CB) method and also to assess the utility and sensitivity of the CB method in the cytodiagnosis of pleural effusions. Materials and Methods: The study was conducted in the cytology section of the Department of Pathology. Sixty pleural fluid samples were subjected to diagnostic evaluation for over a period of 20 months. Along with the conventional smears, cell blocks were prepared by using 10% alcohol–formalin as a fixative agent. Statistical analysis with the ‘z test’ was performed to identify the cellularity, using the CS and CB methods. Mc. Naemer's χ2test was used to identify the additional yield for malignancy by the CB method. Results: Cellularity and additional yield for malignancy was 15% more by the CB method. Conclusions: The CB method provides high cellularity, better architectural patterns, morphological features and an additional yield of malignant cells, and thereby, increases the sensitivity of the cytodiagnosis when compared with the CS method. PMID:22438610

  9. Methods and recommendations for evaluating and reporting a new diagnostic test.

    PubMed

    Hess, A S; Shardell, M; Johnson, J K; Thom, K A; Strassle, P; Netzer, G; Harris, A D

    2012-09-01

    No standardized guidelines exist for the biostatistical methods appropriate for studies evaluating diagnostic tests. Publication recommendations such as the STARD statement provide guidance for the analysis of data, but biostatistical advice is minimal and application is inconsistent. This article aims to provide a self-contained, accessible resource on the biostatistical aspects of study design and reporting for investigators. For all dichotomous diagnostic tests, estimates of sensitivity and specificity should be reported with confidence intervals. Power calculations are strongly recommended to ensure that investigators achieve desired levels of precision. In the absence of a gold standard reference test, the composite reference standard method is recommended for improving estimates of the sensitivity and specificity of the test under evaluation.

  10. Methods and recommendations for evaluating and reporting a new diagnostic test

    PubMed Central

    Shardell, M.; Johnson, J. K.; Thom, K. A.; Strassle, P.; Netzer, G.; Harris, A. D.

    2013-01-01

    No standardized guidelines exist for the biostatistical methods appropriate for studies evaluating diagnostic tests. Publication recommendations such as the STARD statement provide guidance for the analysis of data, but biostatistical advice is minimal and application is inconsistent. This article aims to provide a self-contained, accessible resource on the biostatistical aspects of study design and reporting for investigators. For all dichotomous diagnostic tests, estimates of sensitivity and specificity should be reported with confidence intervals. Power calculations are strongly recommended to ensure that investigators achieve desired levels of precision. In the absence of a gold standard reference test, the composite reference standard method is recommended for improving estimates of the sensitivity and specificity of the test under evaluation. PMID:22476385

  11. Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellarator

    SciTech Connect

    Zhang, D.; Burhenn, R.; Koenig, R.; Giannone, L.; Grodzki, P. A.; Klein, B.; Grosser, K.; Baldzuhn, J.; Ewert, K.; Erckmann, V.; Hirsch, M.; Laqua, H. P.; Oosterbeek, J. W.

    2010-10-15

    A bolometric diagnostic system with features necessary for steady-state operation in the superconducting stellarator W7-X was designed. During a pulse length of 1800 s with an ECRH (electron cyclotron resonance heating) power of 10 MW, the components suffer not only from a large thermal load but also from stray radiation of the nonabsorbed isotropic microwaves. This paper gives an overview of the technical problems encountered during the design work and the solutions to individual problems to meet the special requirements in W7-X, e.g., component thermal protection, detector offset thermal drift suppression, as well as a microwave shielding technique.

  12. Adaptation of LASCA method for diagnostics of malignant tumours in laboratory animals

    SciTech Connect

    Ul'yanov, S S; Laskavyi, V N; Glova, Alina B; Polyanina, T I; Ul'yanova, O V; Fedorova, V A; Ul'yanov, A S

    2012-05-31

    The LASCA method is adapted for diagnostics of malignant neoplasms in laboratory animals. Tumours are studied in mice of Balb/c inbred line after inoculation of cells of syngeneic myeloma cell line Sp.2/0 Ag.8. The appropriateness of using the tLASCA method in tumour investigations is substantiated; its advantages in comparison with the sLASCA method are demonstrated. It is found that the most informative characteristic, indicating the presence of a tumour, is the fractal dimension of LASCA images.

  13. On line diagnostics and self-tuning method for the fluidized bed temperature controller

    NASA Astrophysics Data System (ADS)

    Porzuczek, Jan

    2016-03-01

    The paper presents the method of on-line diagnostics of the bed temperature controller for the fluidized bed boiler. Proposed solution is based on the methods of statistical process control. Detected decrease of the bed temperature control quality is used to activate the controller self-tuning procedure. The algorithm that provides optimal tuning of the bed temperature controller is also proposed. The results of experimental verification of the presented method is attached. Experimental studies were carried out using the 2 MW bubbling fluidized bed boiler.

  14. Adaptation of LASCA method for diagnostics of malignant tumours in laboratory animals

    NASA Astrophysics Data System (ADS)

    Ul'yanov, S. S.; Laskavyi, V. N.; Glova, Alina B.; Polyanina, T. I.; Ul'yanova, O. V.; Fedorova, V. A.; Ul'yanov, A. S.

    2012-05-01

    The LASCA method is adapted for diagnostics of malignant neoplasms in laboratory animals. Tumours are studied in mice of Balb/c inbred line after inoculation of cells of syngeneic myeloma cell line Sp.2/0 — Ag.8. The appropriateness of using the tLASCA method in tumour investigations is substantiated; its advantages in comparison with the sLASCA method are demonstrated. It is found that the most informative characteristic, indicating the presence of a tumour, is the fractal dimension of LASCA images.

  15. Method for remote diagnostics of the internal structure of layered media

    SciTech Connect

    Lychagov, V V; Kal'yanov, A L; Ryabukho, V P; Lyakin, D V

    2008-06-30

    The method of autocorrelation low coherence interferometry is proposed for diagnostics of inhomogeneities and the internal structure of layered technical and biological samples. In this method the low coherence optical field reflected from the layered sample is analysed by using a Michelson interferometer. Because the object is outside the interferometer, the distance between the interferometer and the object under study is not limited and thus the object can move during the measurements. Theoretical substantiation of the autocorrelation method for media with discrete and continuous optical structure modifications is presented. (special issue devoted to application of laser technologies in biophotonics and biomedical studies)

  16. 37 CFR 203.4 - Methods of operation.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Methods of operation. 203.4 Section 203.4 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE... operation. (a) In accordance with section 552(a)(2) of the Freedom of Information Act, the Copyright...

  17. 37 CFR 203.4 - Methods of operation.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2013-07-01 2013-07-01 false Methods of operation. 203.4 Section 203.4 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE... operation. (a) In accordance with section 552(a)(2) of the Freedom of Information Act, the Copyright...

  18. 37 CFR 203.4 - Methods of operation.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2014-07-01 2014-07-01 false Methods of operation. 203.4 Section 203.4 Patents, Trademarks, and Copyrights U.S. COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT... operation. (a) In accordance with section 552(a)(2) of the Freedom of Information Act, the Copyright...

  19. Remarks on the operational method of data treatment

    SciTech Connect

    Silver, G.L.

    1987-11-30

    The operational method for data interpolation is not suitable for problems in three dimensions because too many points are involved. Alternative interpretations of the operational technique are suggested, and new formulas for derivatives on curvilinear data are presented. 3 refs., 1 tab.

  20. Operator performance evaluation using multi criteria decision making methods

    NASA Astrophysics Data System (ADS)

    Rani, Ruzanita Mat; Ismail, Wan Rosmanira; Razali, Siti Fatihah

    2014-06-01

    Operator performance evaluation is a very important operation in labor-intensive manufacturing industry because the company's productivity depends on the performance of its operators. The aims of operator performance evaluation are to give feedback to operators on their performance, to increase company's productivity and to identify strengths and weaknesses of each operator. In this paper, six multi criteria decision making methods; Analytical Hierarchy Process (AHP), fuzzy AHP (FAHP), ELECTRE, PROMETHEE II, Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) and VlseKriterijumska Optimizacija I Kompromisno Resenje (VIKOR) are used to evaluate the operators' performance and to rank the operators. The performance evaluation is based on six main criteria; competency, experience and skill, teamwork and time punctuality, personal characteristics, capability and outcome. The study was conducted at one of the SME food manufacturing companies in Selangor. From the study, it is found that AHP and FAHP yielded the "outcome" criteria as the most important criteria. The results of operator performance evaluation showed that the same operator is ranked the first using all six methods.

  1. Dynamically balanced fuel nozzle and method of operation

    DOEpatents

    Richards, George A.; Janus, Michael C.; Robey, Edward H.

    2000-01-01

    An apparatus and method of operation designed to reduce undesirably high pressure oscillations in lean premix combustion systems burning hydrocarbon fuels are provided. Natural combustion and nozzle acoustics are employed to generate multiple fuel pockets which, when burned in the combustor, counteract the oscillations caused by variations in heat release in the combustor. A hybrid of active and passive control techniques, the apparatus and method eliminate combustion oscillations over a wide operating range, without the use of moving parts or electronics.

  2. Method and Apparatus Providing Deception and/or Altered Operation in an Information System Operating System

    DOEpatents

    Cohen, Fred; Rogers, Deanna T.; Neagoe, Vicentiu

    2008-10-14

    A method and/or system and/or apparatus providing deception and/or execution alteration in an information system. In specific embodiments, deceptions and/or protections are provided by intercepting and/or modifying operation of one or more system calls of an operating system.

  3. The role of ultrasound and nuclear medicine methods in the preoperative diagnostics of primary hyperparathyroidism.

    PubMed

    Nieciecki, Michał; Cacko, Marek; Królicki, Leszek

    2015-12-01

    Primary hyperparathyroidism (PH) represents one of the most common endocrine diseases. In most cases, the disorder is caused by parathyroid adenomas. Bilateral neck exploration has been a widely used treatment method for adenomas since the 20's of the twentieth century. In the last decade, however, it has been increasingly replaced by a minimally invasive surgical treatment. Smaller extent, shorter duration and lower complication rate of such a procedure are emphasized. Its efficacy depends on a precise location of parathyroid tissue during the preoperative imaging. Scintigraphy and ultrasound play a major role in the diagnostic algorithms. The efficacy of both methods has been repeatedly verified and compared. The still-current guidelines of the European Association of Nuclear Medicine (2009) emphasize the complementary role of scintigraphy and ultrasonography in the preoperative diagnostics in patients with primary hyperparathyroidism. At the same time, attempts are made to improve both these techniques by implementing new study protocols or innovative technologies. Publications have emerged in the recent years in the field of ultrasonography, whose authors pointed out the usefulness of elastography and contrast media. Nuclear medicine studies, on the other hand, focus mainly on the assessment of new radiotracers used in the positron emission tomography (PET). The aim of this article is to present, based on literature data, the possibilities of ultrasound and scintigraphy in the preoperative diagnostics in patients with primary hyperparathyroidism. Furthermore, the main directions in the development of imaging techniques in PH patients were evaluated.

  4. Development of a diagnostic method applicable to various serotypes of hantavirus infection in rodents.

    PubMed

    Sanada, Takahiro; Kariwa, Hiroaki; Saasa, Ngonda; Yoshikawa, Keisuke; Seto, Takahiro; Morozov, Vyacheslav G; Tkachenko, Evgeniy A; Ivanov, Leonid I; Yoshimatsu, Kumiko; Arikawa, Jiro; Yoshii, Kentaro; Takashima, Ikuo

    2012-09-01

    Antigenic diversity among different hantaviruses requires a variety of reagents for diagnosis of hantavirus infection. To develop a diagnostic method applicable to various hantavirus infections with a single set of reagents, we developed an enzyme-linked immunosorbent assay (ELISA) using recombinant nucleocapsid proteins of three hantaviruses, Amur, Hokkaido, and Sin Nombre viruses. This novel cocktail antigen-based ELISA enabled detection of antibodies against Hantaan, Seoul, Amur, Puumala, and Sin Nombre viruses in immunized laboratory animals. In wild rodent species, including Apodemus, Rattus, and Myodes, our ELISA detected antibodies against hantaviruses with high sensitivity and specificity. These data suggest that our novel diagnostic ELISA is a useful tool for screening hantavirus infections and could be effectively utilized for serological surveillance and quarantine purposes.

  5. Wavelet operational matrix method for solving the Riccati differential equation

    NASA Astrophysics Data System (ADS)

    Li, Yuanlu; Sun, Ning; Zheng, Bochao; Wang, Qi; Zhang, Yingchao

    2014-03-01

    A Haar wavelet operational matrix method (HWOMM) was derived to solve the Riccati differential equations. As a result, the computation of the nonlinear term was simplified by using the Block pulse function to expand the Haar wavelet one. The proposed method can be used to solve not only the classical Riccati differential equations but also the fractional ones. The capability and the simplicity of the proposed method was demonstrated by some examples and comparison with other methods.

  6. [Forensic medical diagnostics of intra-vitality of the strangulation mark by morphological methods].

    PubMed

    Bogomolov, D V; Zbrueva, Yu V; Putintsev, V A; Denisova, O P

    2016-01-01

    The objective of the present study WaS to overview the current domestic and foreign literature concerning the up-to-date methods employed for the expert evaluation of intra-vitality of the strangulation mark. The secondary objective was to propose the new approaches for addressing this problem. The methods of expert diagnostics with a view to determining the time of infliction of injuries as exemplified by mechanical asphyxia are discussed. It is concluded that immunohistochemical and morphometric studies provide the most promising tools for the evaluation of intra-vitality of the strangulation mark for the purpose of forensic medical expertise.

  7. [Forensic medical diagnostics of intra-vitality of the strangulation mark by morphological methods].

    PubMed

    Bogomolov, D V; Zbrueva, Yu V; Putintsev, V A; Denisova, O P

    2016-01-01

    The objective of the present study WaS to overview the current domestic and foreign literature concerning the up-to-date methods employed for the expert evaluation of intra-vitality of the strangulation mark. The secondary objective was to propose the new approaches for addressing this problem. The methods of expert diagnostics with a view to determining the time of infliction of injuries as exemplified by mechanical asphyxia are discussed. It is concluded that immunohistochemical and morphometric studies provide the most promising tools for the evaluation of intra-vitality of the strangulation mark for the purpose of forensic medical expertise. PMID:27358932

  8. Surgical extraction of lower third molars: diagnostic tests and operative technique in the prevention of inferior alveolar nerve injury. Case study

    PubMed Central

    MELEO, D.; PACIFICI, L.

    2009-01-01

    SUMMARY Increased knowledge and technical refinement have broadened the limits of outpatient oral surgery; however, these changes have at the same time led to a greater number of complications and poor outcomes and, accordingly, to legal action for professional responsibility. Oral surgery represents 10% of all actions, and almost all of these are attributable to exodontic surgery, of which around a third are related to inferior alveolar nerve injury following the extraction of lower third molars. The aim of this case study is to suggest operative technical strategies in accordance with a correct clinical-diagnostic pathway in order to prevent neurological complications involving the inferior alveolar nerve subsequent to lower third molar extraction. Cases should be carefully selected and surgical intervention undertaken solely when genuinely necessary. The patient should be informed of the risks, the methods and the possible results of the treatment. These are the bases for correct indication, along with a sufficient diagnostic path and a good level of communication between operator and patient. PMID:23285341

  9. Inversion methods for the measurements of MHD-like density fluctuations by Heavy Ion Beam Diagnostic

    NASA Astrophysics Data System (ADS)

    Malaquias, A.; Henriques, R. B.; Nedzelsky, I. S.

    2015-09-01

    We report here on the recent developments in the deconvolution of the path integral effects for the study of MHD pressure-like fluctuations measured by Heavy Ion Beam Diagnostic. In particular, we develop improved methods to account for and remove the path integral effect on the determination of the ionization generation factors, including the double ionization of the primary beam. We test the method using the HIBD simulation code which computes the real beam trajectories and attenuations due to electron impact ionization for any selected synthetic profiles of plasma current, plasma potential, electron temperature and density. Simulations have shown the numerical method to be highly effective in ISTTOK within an overall accuracy of a few percent (< 3%). The method here presented can effectively reduce the path integral effects and may serve as the basis to develop improved retrieving techniques for plasma devices working even in higher density ranges. The method is applied to retrieve the time evolution and spatial structure of m=1 and m=2 modes. The 2D MHD mode-like structure is reconstructed by means of a spatial projection of all 1D measurements obtained during one full rotation of the mode. A shorter version of this contribution is due to be published in PoS at: 1st EPS conference on Plasma Diagnostics

  10. Engine systems and methods of operating an engine

    DOEpatents

    Scotto, Mark Vincent

    2015-08-25

    One embodiment of the present invention is a unique method for operating an engine. Another embodiment is a unique engine system. Other embodiments include apparatuses, systems, devices, hardware, methods, and combinations for engines and engine systems. Further embodiments, forms, features, aspects, benefits, and advantages of the present application will become apparent from the description and figures provided herewith.

  11. The Propositional Logic Test as a Diagnostic Tool for Misconceptions about Logical Operations.

    ERIC Educational Resources Information Center

    Almstrum, Vicki L.

    1999-01-01

    Describes a simple 16-item instrument, the Propositional Logic Test (PLT), that is based on Piagetian theory and a study that explored the use of the PLT in diagnosing student misunderstandings. Analysis of individual student responses revealed a number of systematic errors in interpreting the logical operations in the PLT items. (Contains 23…

  12. Personality Assessment in the Diagnostic Manuals: On Mindfulness, Multiple Methods, and Test Score Discontinuities

    PubMed Central

    Bornstein, Robert F.

    2015-01-01

    Recent controversies have illuminated the strengths and limitations of different frameworks for conceptualizing personality pathology (e.g., trait perspectives, categorical models), and stimulated debate regarding how best to diagnose personality disorders (PDs) in DSM-5, and in other diagnostic systems (i.e., the International Classification of Diseases, the Psychodynamic Diagnostic Manual). In this article I argue that regardless of how PDs are conceptualized and which diagnostic system is employed, multi-method assessment must play a central role in PD diagnosis. By complementing self-reports with evidence from other domains (e.g., performance-based tests), a broader range of psychological processes are engaged in the patient, and the impact of self-perception and self-presentation biases may be better understood. By providing the assessor with evidence drawn from multiple modalities, some of which provide converging patterns and some of which yield divergent results, the assessor is compelled to engage this evidence more deeply. The mindful processing that ensues can help minimize the deleterious impact of naturally occurring information processing bias and distortion on the part of the clinician (e.g., heuristics, attribution errors), bringing greater clarity to the synthesis and integration of assessment data. PMID:25856565

  13. Synchronized operation by field programmable gate array based signal controller for the Thomson scattering diagnostic system in KSTAR

    SciTech Connect

    Lee, W. R.; Park, M. K.; Lee, J. H.; Kim, H. S.; Kim, K. H.

    2012-09-15

    The Thomson scattering diagnostic system is successfully installed in the Korea Superconducting Tokamak Advanced Research (KSTAR) facility. We got the electron temperature and electron density data for the first time in 2011, 4th campaign using a field programmable gate array (FPGA) based signal control board. It operates as a signal generator, a detector, a controller, and a time measuring device. This board produces two configurable trigger pulses to operate Nd:YAG laser system and receives a laser beam detection signal from a photodiode detector. It allows a trigger pulse to be delivered to a time delay module to make a scattered signal measurement, measuring an asynchronous time value between the KSTAR timing board and the laser system injection signal. All functions are controlled by the embedded processor running on operating system within a single FPGA. It provides Ethernet communication interface and is configured with standard middleware to integrate with KSTAR. This controller has operated for two experimental campaigns including commissioning and performed the reconfiguration of logic designs to accommodate varying experimental situation without hardware rebuilding.

  14. Support Operators Method for the Diffusion Equation in Multiple Materials

    SciTech Connect

    Winters, Andrew R.; Shashkov, Mikhail J.

    2012-08-14

    A second-order finite difference scheme for the solution of the diffusion equation on non-uniform meshes is implemented. The method allows the heat conductivity to be discontinuous. The algorithm is formulated on a one dimensional mesh and is derived using the support operators method. A key component of the derivation is that the discrete analog of the flux operator is constructed to be the negative adjoint of the discrete divergence, in an inner product that is a discrete analog of the continuum inner product. The resultant discrete operators in the fully discretized diffusion equation are symmetric and positive definite. The algorithm is generalized to operate on meshes with cells which have mixed material properties. A mechanism to recover intermediate temperature values in mixed cells using a limited linear reconstruction is introduced. The implementation of the algorithm is verified and the linear reconstruction mechanism is compared to previous results for obtaining new material temperatures.

  15. Vertical root fracture: Biological effects and accuracy of diagnostic imaging methods

    PubMed Central

    Baageel, Turki M.; Allah, Emad Habib; Bakalka, Ghaida T.; Jadu, Fatima; Yamany, Ibrahim; Jan, Ahmed M.; Bogari, Dania F.; Alhazzazi, Turki Y.

    2016-01-01

    This review assessed the most up-to-date literature on the accuracy of detecting vertical root fractures (VRFs] using the currently available diagnostic imaging methods. In addition, an overview of the biological and clinical aspects of VRFs will also be discussed. A systematic review of the literature was initiated in December of 2015 and then updated in May of 2016. The electronic databases searched included PubMed, Emabse, Ovid, and Google Scholar. An assessment of the methodological quality was performed using a modified version of the quality assessment of diagnostic accuracy studies tool. Twenty-two studies were included in this systematic review after applying specific inclusion and exclusion criteria. Of those, 12 favored using cone beam computed tomography (CBCT) for detecting VRF as compared to periapical radiographs, whereas 5 reported no differences between the two methods. The remaining 5 studies confirmed the advantages associated with using CBCT when diagnosing VRF and described the parameters and limitations associated with this method, but they were not comparative studies. In conclusion, overwhelming evidence suggests that the use of CBCT is a preferred method for detecting VRFs. Nevertheless, additional well controlled and high quality studies are needed to produce solid evidence and guidelines to support the routine use of CBCT in the diagnosis of VRFs as a standard of care. PMID:27652254

  16. Vertical root fracture: Biological effects and accuracy of diagnostic imaging methods

    PubMed Central

    Baageel, Turki M.; Allah, Emad Habib; Bakalka, Ghaida T.; Jadu, Fatima; Yamany, Ibrahim; Jan, Ahmed M.; Bogari, Dania F.; Alhazzazi, Turki Y.

    2016-01-01

    This review assessed the most up-to-date literature on the accuracy of detecting vertical root fractures (VRFs] using the currently available diagnostic imaging methods. In addition, an overview of the biological and clinical aspects of VRFs will also be discussed. A systematic review of the literature was initiated in December of 2015 and then updated in May of 2016. The electronic databases searched included PubMed, Emabse, Ovid, and Google Scholar. An assessment of the methodological quality was performed using a modified version of the quality assessment of diagnostic accuracy studies tool. Twenty-two studies were included in this systematic review after applying specific inclusion and exclusion criteria. Of those, 12 favored using cone beam computed tomography (CBCT) for detecting VRF as compared to periapical radiographs, whereas 5 reported no differences between the two methods. The remaining 5 studies confirmed the advantages associated with using CBCT when diagnosing VRF and described the parameters and limitations associated with this method, but they were not comparative studies. In conclusion, overwhelming evidence suggests that the use of CBCT is a preferred method for detecting VRFs. Nevertheless, additional well controlled and high quality studies are needed to produce solid evidence and guidelines to support the routine use of CBCT in the diagnosis of VRFs as a standard of care.

  17. Vertical root fracture: Biological effects and accuracy of diagnostic imaging methods.

    PubMed

    Baageel, Turki M; Allah, Emad Habib; Bakalka, Ghaida T; Jadu, Fatima; Yamany, Ibrahim; Jan, Ahmed M; Bogari, Dania F; Alhazzazi, Turki Y

    2016-08-01

    This review assessed the most up-to-date literature on the accuracy of detecting vertical root fractures (VRFs] using the currently available diagnostic imaging methods. In addition, an overview of the biological and clinical aspects of VRFs will also be discussed. A systematic review of the literature was initiated in December of 2015 and then updated in May of 2016. The electronic databases searched included PubMed, Emabse, Ovid, and Google Scholar. An assessment of the methodological quality was performed using a modified version of the quality assessment of diagnostic accuracy studies tool. Twenty-two studies were included in this systematic review after applying specific inclusion and exclusion criteria. Of those, 12 favored using cone beam computed tomography (CBCT) for detecting VRF as compared to periapical radiographs, whereas 5 reported no differences between the two methods. The remaining 5 studies confirmed the advantages associated with using CBCT when diagnosing VRF and described the parameters and limitations associated with this method, but they were not comparative studies. In conclusion, overwhelming evidence suggests that the use of CBCT is a preferred method for detecting VRFs. Nevertheless, additional well controlled and high quality studies are needed to produce solid evidence and guidelines to support the routine use of CBCT in the diagnosis of VRFs as a standard of care. PMID:27652254

  18. High-Accuracy Ultrasound Contrast Agent Detection Method for Diagnostic Ultrasound Imaging Systems.

    PubMed

    Ito, Koichi; Noro, Kazumasa; Yanagisawa, Yukari; Sakamoto, Maya; Mori, Shiro; Shiga, Kiyoto; Kodama, Tetsuya; Aoki, Takafumi

    2015-12-01

    An accurate method for detecting contrast agents using diagnostic ultrasound imaging systems is proposed. Contrast agents, such as microbubbles, passing through a blood vessel during ultrasound imaging are detected as blinking signals in the temporal axis, because their intensity value is constantly in motion. Ultrasound contrast agents are detected by evaluating the intensity variation of a pixel in the temporal axis. Conventional methods are based on simple subtraction of ultrasound images to detect ultrasound contrast agents. Even if the subject moves only slightly, a conventional detection method will introduce significant error. In contrast, the proposed technique employs spatiotemporal analysis of the pixel intensity variation over several frames. Experiments visualizing blood vessels in the mouse tail illustrated that the proposed method performs efficiently compared with conventional approaches. We also report that the new technique is useful for observing temporal changes in microvessel density in subiliac lymph nodes containing tumors. The results are compared with those of contrast-enhanced computed tomography.

  19. Molecular Diagnostics for Lassa Fever at Irrua Specialist Teaching Hospital, Nigeria: Lessons Learnt from Two Years of Laboratory Operation

    PubMed Central

    Hass, Meike; Gabriel, Martin; Ölschläger, Stephan; Becker-Ziaja, Beate; Folarin, Onikepe; Phelan, Eric; Ehiane, Philomena E.; Ifeh, Veritas E.; Uyigue, Eghosasere A.; Oladapo, Yemisi T.; Muoebonam, Ekene B.; Osunde, Osagie; Dongo, Andrew; Okokhere, Peter O.; Okogbenin, Sylvanus A.; Momoh, Mojeed; Alikah, Sylvester O.; Akhuemokhan, Odigie C.; Imomeh, Peter; Odike, Maxy A. C.; Gire, Stephen; Andersen, Kristian; Sabeti, Pardis C.; Happi, Christian T.; Akpede, George O.; Günther, Stephan

    2012-01-01

    Background Lassa fever is a viral hemorrhagic fever endemic in West Africa. However, none of the hospitals in the endemic areas of Nigeria has the capacity to perform Lassa virus diagnostics. Case identification and management solely relies on non-specific clinical criteria. The Irrua Specialist Teaching Hospital (ISTH) in the central senatorial district of Edo State struggled with this challenge for many years. Methodology/Principal Findings A laboratory for molecular diagnosis of Lassa fever, complying with basic standards of diagnostic PCR facilities, was established at ISTH in 2008. During 2009 through 2010, samples of 1,650 suspected cases were processed, of which 198 (12%) tested positive by Lassa virus RT-PCR. No remarkable demographic differences were observed between PCR-positive and negative patients. The case fatality rate for Lassa fever was 31%. Nearly two thirds of confirmed cases attended the emergency departments of ISTH. The time window for therapeutic intervention was extremely short, as 50% of the fatal cases died within 2 days of hospitalization—often before ribavirin treatment could be commenced. Fatal Lassa fever cases were older (p = 0.005), had lower body temperature (p<0.0001), and had higher creatinine (p<0.0001) and blood urea levels (p<0.0001) than survivors. Lassa fever incidence in the hospital followed a seasonal pattern with a peak between November and March. Lassa virus sequences obtained from the patients originating from Edo State formed—within lineage II—a separate clade that could be further subdivided into three clusters. Conclusions/Significance Lassa fever case management was improved at a tertiary health institution in Nigeria through establishment of a laboratory for routine diagnostics of Lassa virus. Data collected in two years of operation demonstrate that Lassa fever is a serious public health problem in Edo State and reveal new insights into the disease in hospitalized patients. PMID:23029594

  20. The Diagnostic Accuracy of Serologic and Molecular Methods for Detecting Visceral Leishmaniasis in HIV Infected Patients: Meta-Analysis

    PubMed Central

    Cota, Gláucia Fernandes; de Sousa, Marcos Roberto; Demarqui, Fábio Nogueira; Rabello, Ana

    2012-01-01

    Background Human visceral leishmaniasis (VL), a potentially fatal disease, has emerged as an important opportunistic condition in HIV infected patients. In immunocompromised patients, serological investigation is considered not an accurate diagnostic method for VL diagnosis and molecular techniques seem especially promising. Objective This work is a comprehensive systematic review and meta-analysis to evaluate the accuracy of serologic and molecular tests for VL diagnosis specifically in HIV-infected patients. Methods Two independent reviewers searched PubMed and LILACS databases. The quality of studies was assessed by QUADAS score. Sensitivity and specificity were pooled separately and compared with overall accuracy measures: diagnostic odds ratio (DOR) and symmetric summary receiver operating characteristic (sROC). Results Thirty three studies recruiting 1,489 patients were included. The following tests were evaluated: Immunofluorescence Antibody Test (IFAT), Enzyme linked immunosorbent assay (ELISA), immunoblotting (Blot), direct agglutination test (DAT) and polimerase chain reaction (PCR) in whole blood and bone marrow. Most studies were carried out in Europe. Serological tests varied widely in performance, but with overall limited sensitivity. IFAT had poor sensitivity ranging from 11% to 82%. DOR (95% confidence interval) was higher for DAT 36.01 (9.95–130.29) and Blot 27.51 (9.27–81.66) than for IFAT 7.43 (3.08–1791) and ELISA 3.06 (0.71–13.10). PCR in whole blood had the highest DOR: 400.35 (58.47–2741.42). The accuracy of PCR based on Q-point was 0.95; 95%CI 0.92–0.97, which means good overall performance. Conclusion Based mainly on evidence gained by infection with Leishmania infantum chagasi, serological tests should not be used to rule out a diagnosis of VL among the HIV-infected, but a positive test at even low titers has diagnostic value when combined with the clinical case definition. Considering the available evidence, tests based on DNA

  1. New diagnostic methods for laser plasma- and microwave-enhanced combustion.

    PubMed

    Miles, Richard B; Michael, James B; Limbach, Christopher M; McGuire, Sean D; Chng, Tat Loon; Edwards, Matthew R; DeLuca, Nicholas J; Shneider, Mikhail N; Dogariu, Arthur

    2015-08-13

    The study of pulsed laser- and microwave-induced plasma interactions with atmospheric and higher pressure combusting gases requires rapid diagnostic methods that are capable of determining the mechanisms by which these interactions are taking place. New rapid diagnostics are presented here extending the capabilities of Rayleigh and Thomson scattering and resonance-enhanced multi-photon ionization (REMPI) detection and introducing femtosecond laser-induced velocity and temperature profile imaging. Spectrally filtered Rayleigh scattering provides a method for the planar imaging of temperature fields for constant pressure interactions and line imaging of velocity, temperature and density profiles. Depolarization of Rayleigh scattering provides a measure of the dissociation fraction, and multi-wavelength line imaging enables the separation of Thomson scattering from Rayleigh scattering. Radar REMPI takes advantage of high-frequency microwave scattering from the region of laser-selected species ionization to extend REMPI to atmospheric pressures and implement it as a stand-off detection method for atomic and molecular species in combusting environments. Femtosecond laser electronic excitation tagging (FLEET) generates highly excited molecular species and dissociation through the focal zone of the laser. The prompt fluorescence from excited molecular species yields temperature profiles, and the delayed fluorescence from recombining atomic fragments yields velocity profiles. PMID:26170432

  2. New diagnostic methods for laser plasma- and microwave-enhanced combustion

    PubMed Central

    Miles, Richard B; Michael, James B; Limbach, Christopher M; McGuire, Sean D; Chng, Tat Loon; Edwards, Matthew R; DeLuca, Nicholas J; Shneider, Mikhail N; Dogariu, Arthur

    2015-01-01

    The study of pulsed laser- and microwave-induced plasma interactions with atmospheric and higher pressure combusting gases requires rapid diagnostic methods that are capable of determining the mechanisms by which these interactions are taking place. New rapid diagnostics are presented here extending the capabilities of Rayleigh and Thomson scattering and resonance-enhanced multi-photon ionization (REMPI) detection and introducing femtosecond laser-induced velocity and temperature profile imaging. Spectrally filtered Rayleigh scattering provides a method for the planar imaging of temperature fields for constant pressure interactions and line imaging of velocity, temperature and density profiles. Depolarization of Rayleigh scattering provides a measure of the dissociation fraction, and multi-wavelength line imaging enables the separation of Thomson scattering from Rayleigh scattering. Radar REMPI takes advantage of high-frequency microwave scattering from the region of laser-selected species ionization to extend REMPI to atmospheric pressures and implement it as a stand-off detection method for atomic and molecular species in combusting environments. Femtosecond laser electronic excitation tagging (FLEET) generates highly excited molecular species and dissociation through the focal zone of the laser. The prompt fluorescence from excited molecular species yields temperature profiles, and the delayed fluorescence from recombining atomic fragments yields velocity profiles. PMID:26170432

  3. White-Nose Syndrome Disease Severity and a Comparison of Diagnostic Methods.

    PubMed

    McGuire, Liam P; Turner, James M; Warnecke, Lisa; McGregor, Glenna; Bollinger, Trent K; Misra, Vikram; Foster, Jeffrey T; Frick, Winifred F; Kilpatrick, A Marm; Willis, Craig K R

    2016-03-01

    White-nose syndrome is caused by the fungus Pseudogymnoascus destructans and has killed millions of hibernating bats in North America but the pathophysiology of the disease remains poorly understood. Our objectives were to (1) assess non-destructive diagnostic methods for P. destructans infection compared to histopathology, the current gold-standard, and (2) to evaluate potential metrics of disease severity. We used data from three captive inoculation experiments involving 181 little brown bats (Myotis lucifugus) to compare histopathology, quantitative PCR (qPCR), and ultraviolet fluorescence as diagnostic methods of P. destructans infection. To assess disease severity, we considered two histology metrics (wing area with fungal hyphae, area of dermal necrosis), P. destructans fungal load (qPCR), ultraviolet fluorescence, and blood chemistry (hematocrit, sodium, glucose, pCO2, and bicarbonate). Quantitative PCR was most effective for early detection of P. destructans, while all three methods were comparable in severe infections. Correlations among hyphae and necrosis scores, qPCR, ultraviolet fluorescence, blood chemistry, and hibernation duration indicate a multi-stage pattern of disease. Disruptions of homeostasis occurred rapidly in late hibernation. Our results provide valuable information about the use of non-destructive techniques for monitoring, and provide novel insight into the pathophysiology of white-nose syndrome, with implications for developing and implementing potential mitigation strategies. PMID:26957435

  4. Systems and methods for analyzing building operations sensor data

    DOEpatents

    Mezic, Igor; Eisenhower, Bryan A.

    2015-05-26

    Systems and methods are disclosed for analyzing building sensor information and decomposing the information therein to a more manageable and more useful form. Certain embodiments integrate energy-based and spectral-based analysis methods with parameter sampling and uncertainty/sensitivity analysis to achieve a more comprehensive perspective of building behavior. The results of this analysis may be presented to a user via a plurality of visualizations and/or used to automatically adjust certain building operations. In certain embodiments, advanced spectral techniques, including Koopman-based operations, are employed to discern features from the collected building sensor data.

  5. Method for operating a combustor in a fuel cell system

    DOEpatents

    Clingerman, Bruce J.; Mowery, Kenneth D.

    2002-01-01

    In one aspect, the invention provides a method of operating a combustor to heat a fuel processor to a desired temperature in a fuel cell system, wherein the fuel processor generates hydrogen (H.sub.2) from a hydrocarbon for reaction within a fuel cell to generate electricity. More particularly, the invention provides a method and select system design features which cooperate to provide a start up mode of operation and a smooth transition from start-up of the combustor and fuel processor to a running mode.

  6. Centrifuge-operated specimen staining method and apparatus

    NASA Technical Reports Server (NTRS)

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  7. Daily Fill Factor Variation as a Diagnostic Probe of Multijunction Concentrator Systems During Outdoor Operation

    SciTech Connect

    McMahon, W. E.; Emery, K. E.; Friedman, D. J.; Ottoson, L.; Young, M. S.; Ward, J. S.; Kramer, C. M.; Duda, A.; Kurtz, S.

    2007-01-01

    The work presented here is for GaInP2/GaAs tandem cells, but the conclusions are equally valid for GaInP2/GaAs/Ge triple-junction cells. Optimizing a concentrator system which uses multijunction solar cells is challenging because: (a) the conditions are variable, so the solar cells rarely operate under optimal conditions and (b) the conditions are not controlled, so any design problems are difficult to characterize. Any change in the spectral content of direct-beam sunlight as it passes through the concentrator optics is of particular interest, as it can reduce the performance of multijunction cells and is difficult to characterize.

  8. Combined Use of Cytogenetic and Molecular Methods in Prenatal Diagnostics of Chromosomal Abnormalities

    PubMed Central

    Stomornjak-Vukadin, Meliha; Kurtovic-Basic, Ilvana; Mehinovic, Lejla; Konjhodzic, Rijad

    2015-01-01

    Aim: The aim of prenatal diagnostics is to provide information of the genetic abnormalities of the fetus early enough for the termination of pregnancy to be possible. Chromosomal abnormalities can be detected in an unborn child through the use of cytogenetic, molecular- cytogenetic and molecular methods. In between them, central spot is still occupied by cytogenetic methods. In cases where use of such methods is not informative enough, one or more molecular cytogenetic methods can be used for further clarification. Combined use of the mentioned methods improves the quality of the final findings in the diagnostics of chromosomal abnormalities, with classical cytogenetic methods still occupying the central spot. Material and methods: Conducted research represent retrospective-prospective study of a four year period, from 2008 through 2011. In the period stated, 1319 karyotyping from amniotic fluid were conducted, along with 146 FISH analysis. Results: Karyotyping had detected 20 numerical and 18 structural aberrations in that period. Most common observed numerical aberration were Down syndrome (75%), Klinefelter syndrome (10%), Edwards syndrome, double Y syndrome and triploidy (5% each). Within observed structural aberrations more common were balanced chromosomal aberrations then non balanced ones. Most common balanced structural aberrations were as follows: reciprocal translocations (60%), Robertson translocations (13.3%), chromosomal inversions, duplications and balanced de novo chromosomal rearrangements (6.6% each). Conclusion: With non- balanced aberrations observed in the samples of amniotic fluid, non- balanced translocations, deletions and derived chromosomes were equally represented. Number of detected aneuploidies with FISH, prior to obtaining results with karyotyping, were 6. PMID:26005269

  9. Alternative methods of optical diagnostics in the field of standardization and metrology

    NASA Astrophysics Data System (ADS)

    Constantinov, Boris I.; Pasechnic, Teodosie I.; Sircu, Sergiu

    2000-10-01

    An optical configuration based on the photothermoplastic recording (PTPR) is suggested for the operational optical diagnostics and standardization of the products in the real time scale. The presence of three or four PTPR cameras along the counter of the tested product makes it possible to investigate in the real-time scale not only the appearance of the internal defects, but also the influence of the condition of different units onto the condition of the whole system. Dry development of the images in the real-time scale and instant fixation of images on the photothermoplastic carriers (PTPC) followed by the computer analysis used to compare the product and the standard allow us to gain in time and areas.

  10. Diagnostic accuracy of pre-operative imaging findings in presumed clinical T1a renal cell carcinomas

    PubMed Central

    NAKASHIMA, KAZUFUMI; KITAGAWA, YASUHIDE; IZUMI, KOUJI; MIZOKAMI, ATSUSHI; GABATA, TOSHIFUMI; NAMIKI, MIKIO

    2016-01-01

    Despite the development of recent imaging modalities, certain pathological misdiagnoses remain for surgical specimens of presumed small renal cell carcinomas (RCCs). In the present study, a retrospective analysis of benign pathological lesions diagnosed as small RCC prior to surgery was performed. In total, the cases of 196 sporadic renal tumors that was surgically treated as clinical T1a RCCs were reviewed, and the accuracy of the pathological diagnoses was calculated. The pre-operative findings for benign pathological lesions was investigated, and the lesions were observed in 13 (6.63%) of the 196 tumors. Pre-operative computed tomography images were obtained in all cases, and magnetic resonance images were available in 10 cases. The diagnostic accuracy of imaging modalities was significantly lower in the tumors with a diameter of ≤20 mm. In all cases, the possible pathological diagnosis of RCC could not be excluded even by retrospective imaging analysis. Several benign pathological lesions were found in small renal masses presumed to be clinical T1a RCC. In conclusion, there may be limitations to the pre-operative imaging for certain types of small renal mass. PMID:27123087

  11. Detecting microcalcifications in mammograms by using SVM method for the diagnostics of breast cancer

    NASA Astrophysics Data System (ADS)

    Wan, Baikun; Wang, Ruiping; Qi, Hongzhi; Cao, Xuchen

    2005-01-01

    Support vector machine (SVM) is a new statistical learning method. Compared with the classical machine learning methods, SVM learning discipline is to minimize the structural risk instead of the empirical risk of the classical methods, and it gives better generative performance. Because SVM algorithm is a convex quadratic optimization problem, the local optimal solution is certainly the global optimal one. In this paper a SVM algorithm is applied to detect the micro-calcifications (MCCs) in mammograms for the diagnostics of breast cancer that has not been reported yet. It had been tested with 10 mammograms and the results show that the algorithm can achieve a higher true positive in comparison with artificial neural network (ANN) based on the empirical risk minimization, and is valuable for further study and application in the clinical engineering.

  12. Dusty plasma diagnostics methods for charge, electron temperature, and ion density

    SciTech Connect

    Liu Bin; Goree, J.; Fortov, V. E.; Lipaev, A. M.; Molotkov, V. I.; Petrov, O. F.; Morfill, G. E.; Thomas, H. M.; Ivlev, A. V.

    2010-05-15

    Diagnostic methods are developed to measure the microparticle charge Q and two plasma parameters, electron temperature T{sub e}, and ion density n{sub i}, in the main plasma region of a dusty plasma. Using video microscopy to track microparticles yields a resonance frequency, which along with a charging model allows an estimation of Q and T{sub e}. Only measurements of microparticle position and velocity are required, unlike other methods that use measurements of T{sub e} and plasma parameters as inputs. The resonance frequency measurement can also be used with an ion drag model to estimate n{sub i}. These methods are demonstrated using a single-layer dusty plasma suspension under microgravity conditions.

  13. Investigation of opportunities of the optical non-invasive diagnostics method for the blood sugar control

    NASA Astrophysics Data System (ADS)

    Lastovskaia, Elena A.; Gorbunova, Elena V.; Chertov, Aleksandr N.; Korotaev, Valery V.

    2015-03-01

    The relevance of noninvasive method for determining the blood sugar is caused by necessity of regular monitoring of glucose levels in diabetic patients blood. Traditional invasive method is painful, because it requires a finger pricking. Despite the active studies in the field of non-invasive medical diagnostics, to date the painless and inexpensive instrument for blood sugar control for personal use doesn't exist. It's possible to measure the concentration of glucose in the blood with help of spectrophotometry method. It consists of registering and analyzing the spectral characteristics of the radiation which missed, reflected or absorbed by the object. The authors proposed a measuring scheme for studying the spectral characteristics of the radiation, missed by earlobe. Ultra-violet, visible and near infrared spectral ranges are considered. The paper presents the description of construction and working principles of the proposed special retaining clip and results of experiment with real patient.

  14. Fluorescent-spectroscopic and imaging methods of investigations for diagnostics of head and neck tumors and control of PDT

    NASA Astrophysics Data System (ADS)

    Edinak, N. E.; Chental, Victor V.; Komov, D.; Vaculovskaya, E.; Tabolinovskaya, T. D.; Abdullin, N. A.; Pustynsky, I.; Chatikhin, V.; Loschenov, Victor B.; Meerovich, Gennady A.; Stratonnikov, A. A.; Linkov, Kirill G.; Agafonov, Vladimir I.; Zuravleva, V.; Lukjanets, E.

    1996-01-01

    Methodics of PDT control and fluorescent-spectroscopic diagnostic of head and neck tumors and mammary gland cancer (nodular) with the use of Kr, He-Ne and semiconductor lasers and photosensitizer (PS) -- Al phtalocyanin (Photosense) are discussed. The results show that applied diagnostic methods permit us not only to identify the topology and malignancy of a tumor but also to correct PDT process directly during irradiation.

  15. Evaluation of three rapid diagnostic methods for direct identification of microorganisms in positive blood cultures.

    PubMed

    Martinez, Raquel M; Bauerle, Elizabeth R; Fang, Ferric C; Butler-Wu, Susan M

    2014-07-01

    The identification of organisms from positive blood cultures generally takes several days. However, recently developed rapid diagnostic methods offer the potential for organism identification within only a few hours of blood culture positivity. In this study, we evaluated the performance of three commercial methods to rapidly identify organisms directly from positive blood cultures: QuickFISH (AdvanDx, Wolburn, MA), Verigene Gram-Positive Blood Culture (BC-GP; Nanosphere, Northbrook, IL), and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) with Sepsityper processing (Bruker Daltonics, Billerica, MA). A total of 159 blood cultures (VersaTREK Trek Diagnostic Systems, Cleveland, OH) positive for Gram-positive and Gram-negative bacteria as well as yeast were analyzed with QuickFISH and MALDI-TOF MS. In all, 102 blood cultures were analyzed using the BC-GP assay. For monomicrobial cultures, we observed 98.0% concordance with routine methods for both QuickFISH (143/146) and the BC-GP assay (93/95). MALDI-TOF MS demonstrated 80.1% (117/146) and 87.7% (128/146) concordance with routine methods to the genus and species levels, respectively. None of the methods tested were capable of consistently identifying polymicrobial cultures in their entirety or reliably differentiating Streptococcus pneumoniae from viridans streptococci. Nevertheless, the methods evaluated in this study are convenient and accurate for the most commonly encountered pathogens and have the potential to dramatically reduce turnaround time for the provision of results to the treating physician.

  16. Evaluation of Three Rapid Diagnostic Methods for Direct Identification of Microorganisms in Positive Blood Cultures

    PubMed Central

    Martinez, Raquel M.; Bauerle, Elizabeth R.; Fang, Ferric C.

    2014-01-01

    The identification of organisms from positive blood cultures generally takes several days. However, recently developed rapid diagnostic methods offer the potential for organism identification within only a few hours of blood culture positivity. In this study, we evaluated the performance of three commercial methods to rapidly identify organisms directly from positive blood cultures: QuickFISH (AdvanDx, Wolburn, MA), Verigene Gram-Positive Blood Culture (BC-GP; Nanosphere, Northbrook, IL), and matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) with Sepsityper processing (Bruker Daltonics, Billerica, MA). A total of 159 blood cultures (VersaTREK Trek Diagnostic Systems, Cleveland, OH) positive for Gram-positive and Gram-negative bacteria as well as yeast were analyzed with QuickFISH and MALDI-TOF MS. In all, 102 blood cultures were analyzed using the BC-GP assay. For monomicrobial cultures, we observed 98.0% concordance with routine methods for both QuickFISH (143/146) and the BC-GP assay (93/95). MALDI-TOF MS demonstrated 80.1% (117/146) and 87.7% (128/146) concordance with routine methods to the genus and species levels, respectively. None of the methods tested were capable of consistently identifying polymicrobial cultures in their entirety or reliably differentiating Streptococcus pneumoniae from viridans streptococci. Nevertheless, the methods evaluated in this study are convenient and accurate for the most commonly encountered pathogens and have the potential to dramatically reduce turnaround time for the provision of results to the treating physician. PMID:24808235

  17. Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method

    SciTech Connect

    Kim, Dong-Hwan; Hong, Suk-Ho; Park, Il-Seo; Lee, Hyo-Chang; Kang, Hyun-Ju; Chung, Chin-Wook

    2015-12-15

    Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method.

  18. Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method

    NASA Astrophysics Data System (ADS)

    Kim, Dong-Hwan; Hong, Suk-Ho; Park, Il-Seo; Lee, Hyo-Chang; Kang, Hyun-Ju; Chung, Chin-Wook

    2015-12-01

    Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method.

  19. Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method.

    PubMed

    Kim, Dong-Hwan; Hong, Suk-Ho; Park, Il-Seo; Lee, Hyo-Chang; Kang, Hyun-Ju; Chung, Chin-Wook

    2015-12-01

    Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method.

  20. Probe diagnostics in the far scrape-off layer plasma of Korea Superconducting Tokamak Advanced Research tokamak using a sideband harmonic method.

    PubMed

    Kim, Dong-Hwan; Hong, Suk-Ho; Park, Il-Seo; Lee, Hyo-Chang; Kang, Hyun-Ju; Chung, Chin-Wook

    2015-12-01

    Plasma characteristics in the far scrape-off layer region of tokamak play a crucial role in the stable plasma operation and its sustainability. Due to the huge facility, electrical diagnostic systems to measure plasma properties have extremely long cable length resulting in large stray current. To overcome this problem, a sideband harmonic method was applied to the Korea Superconducting Tokamak Advanced Research tokamak plasma. The sideband method allows the measurement of the electron temperature and the plasma density without the effect of the stray current. The measured plasma densities are compared with those from the interferometer, and the results show reliability of the method. PMID:26724028

  1. A quantitative diagnostic method for oral mucous precancerosis by Rose Bengal fluorescence spectroscopy.

    PubMed

    Zhang, Lei; Bi, Liangjia; Shi, Jinna; Zhang, Zhiguo; Cao, Wenwu; Lin, Jiang; Li, Chengzhang; Bi, Jiarui; Yu, Yang

    2013-01-01

    A novel in vivo fluorescence spectroscopic diagnostic method has been developed in an animal model to make a quantified precancer diagnosis. In the study, 40 golden hamsters were randomly divided into four groups (groups A, B, C, and D), with group A being the control group and the other three groups being inducted at different precancer stages. A 1% Rose Bengal (RB) solution was used for the fluorescence spectroscopic diagnosis. A parameter K defined as K = I(RB)/I(auto) was introduced to reflect the amount of RB in the tissue, where I(RB) and I(auto) represent the fluorescence peak intensity of the RB in the tissue and the autofluorescence intensity of tissue at 580 nm, respectively. The average K values of the four groups were calculated and statistically analyzed by analysis of variance (ANOVA), which revealed statistically significant differences within each group as well as between groups (p < 0.001). After analysis by Clementine 11.1 C&R Tree modeling (CART), the following diagnostic criteria were set: normal, K ≤ 8.91; simple hyperplasia, 8.91 < K ≤ 41.92; mild dysplasia, 41.92 < K ≤ 70.79; moderate and severe dysplasia, K >70.79. The sensitivity and specificity to detect precancerous lesions compared with scalpel biopsy were calculated. The results of this study showed that the spectrofluorometric method mediated by RB could accurately discriminate different precancer stages.

  2. BREAST: a novel method to improve the diagnostic efficacy of mammography

    NASA Astrophysics Data System (ADS)

    Brennan, P. C.; Tapia, K.; Ryan, J.; Lee, W.

    2013-03-01

    High quality breast imaging and accurate image assessment are critical to the early diagnoses, treatment and management of women with breast cancer. Breast Screen Reader Assessment Strategy (BREAST) provides a platform, accessible by researchers and clinicians world-wide, which will contain image data bases, algorithms to assess reader performance and on-line systems for image evaluation. The platform will contribute to the diagnostic efficacy of breast imaging in Australia and beyond on two fronts: reducing errors in mammography, and transforming our assessment of novel technologies and techniques. Mammography is the primary diagnostic tool for detecting breast cancer with over 800,000 women X-rayed each year in Australia, however, it fails to detect 30% of breast cancers with a number of missed cancers being visible on the image [1-6]. BREAST will monitor the mistakes, identify reasons for mammographic errors, and facilitate innovative solutions to reduce error rates. The BREAST platform has the potential to enable expert assessment of breast imaging innovations, anywhere in the world where experts or innovations are located. Currently, innovations are often being assessed by limited numbers of individuals who happen to be geographically located close to the innovation, resulting in equivocal studies with low statistical power. BREAST will transform this current paradigm by enabling large numbers of experts to assess any new method or technology using our embedded evaluation methods. We are confident that this world-first system will play an important part in the future efficacy of breast imaging.

  3. [Clinical usefulness of diagnostic methods for human papilloma virus dependent lesions].

    PubMed

    Suwalska, Anna; Owczarek, Witold; Fiedor, Piotr

    2014-02-01

    Persistent infection of Human Papilloma Virus (HPV) is confirmed necessary factor for development of cervical cancer and anogenital neoplasia. DNA HPV is detected in 96% of cervical cancer, 40% of vulvar and vaginal cancer, 90% of anal cancer and 26% of oral cavity cancer cases in general population. The most common high-risk HPV types observed in anogenital intraepithelial neoplasia or anogenital cancer are HPV 16, 18 and 45. Numerous diagnostic methods of detection of HPV infection and lesions causes by persistent HPV infection are widely used. Epidemiological data reveals correlation of incidence and mortality reduction due to cervical cancer and consequent prosecution and improvement of screening programmes based on morphological assessment of exfoliative smears. In last decade some limitations of conventional smear method were pointed out and a new diagnostic techniques were introduced: liquid-based cytology and HPV DNA testing. Combination of cytological examination and HPV DNA testing seems to be optimal solution to be introduced in large population because of combining high sensitivity of molecular test with high specificity of cytological smear. PMID:24720112

  4. 12 CFR 1101.3 - Organization and methods of operation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Section 1101.3 Banks and Banking FEDERAL FINANCIAL INSTITUTIONS EXAMINATION COUNCIL DESCRIPTION OF OFFICE, PROCEDURES, PUBLIC INFORMATION § 1101.3 Organization and methods of operation. (a) Statutory requirements... financial institutions supervisory agencies. (e) Council address. Council offices are located at 1776...

  5. Digital Breast Tomosynthesis: A New Diagnostic Method for Mass-Like Lesions in Dense Breasts.

    PubMed

    Bian, Tiantian; Lin, Qing; Cui, Chunxiao; Li, Lili; Qi, Chunhua; Fei, Jie; Su, Xiaohui

    2016-09-01

    To compare the rates and accuracy of digital breast tomosynthesis (DBT) and 2D digital mammography (DM) for detecting and diagnosing mass-like lesions in dense breasts. Mediolateral and craniocaudal images taken with DBT (affected breast) and DM (both breasts) of the dense breasts of 631 women were assessed independently using Breast Imaging Reporting and Data System (BI-RADS) scores. Images were compared for detection and diagnostic accuracy for masses; sensitivity and specificity of diagnosis; false-negative and recall rates; and clarity of display, particularly of margins and spicules. Histopathology was conducted via surgical biopsies of all patients. The detection and diagnostic accuracy rates of DBT images (84.3% and 82.3%, respectively) were significantly higher than that of DM (77.3% and 73.4%; p < 0.01, both). The sensitivity and specificity of DBT (68.1% and 95.2%) were higher than that of DM (58.8% and 86.7%), whereas the recall rate of DBT was lower (3.6% cf. 9.8%). The number of cases of benign circumscribed masses and malignant spiculated masses detected by DBT (172 and 182) was significantly higher than the number detected through DM (75 and 115; p < 0.01, both). Radiologists assigned higher BI-RADS scores for probability of malignancy to DBT images than DM, to lesions proved malignant (p = 0.025); for benign cases, the methods were comparable (p = 0.065). Compared with DM, DBT yielded significantly higher rates of detection and diagnostic accuracy for benign and malignant masses, with greater sensitivity and specificity and lower recall rates. In addition, DBT images facilitated analysis of margins, and the rate of accuracy for judgments of malignancy probability was higher, as proved on biopsy. PMID:27296324

  6. A simple method of observation impact analysis for operational storm surge forecasting systems

    NASA Astrophysics Data System (ADS)

    Sumihar, Julius; Verlaan, Martin

    2016-04-01

    In this work, a simple method is developed for analyzing the impact of assimilating observations in improving forecast accuracy of a model. The method simply makes use of observation time series and the corresponding model output that are generated without data assimilation. These two time series are usually available in an operational database. The method is therefore easy to implement. Moreover, it can be used before actually implementing any data assimilation to the forecasting system. In this respect, it can be used as a tool for designing a data assimilation system, namely for searching for an optimal observing network. The method can also be used as a diagnostic tool, for example, for evaluating an existing operational data assimilation system to check if all observations are contributing positively to the forecast accuracy. The method has been validated with some twin experiments using a simple one-dimensional advection model as well as with an operational storm surge forecasting system based on the Dutch Continental Shelf model version 5 (DCSMv5). It has been applied for evaluating the impact of observations in the operational data assimilation system with DCSMv5 and for designing a data assimilation system for the new model DCSMv6. References: Verlaan, M. and J. Sumihar (2016), Observation impact analysis methods for storm surge forecasting systems, Ocean Dynamics, ODYN-D-15-00061R1 (in press) Zijl, F., J. Sumihar, and M. Verlaan (2015), Application of data assimilation for improved operational water level forecasting of the northwest European shelf and North Sea, Ocean Dynamics, 65, Issue 12, pp 1699-1716.

  7. Crystallo-optic diagnostics method of the soft laser-induced effects in biological fluids

    NASA Astrophysics Data System (ADS)

    Skopinov, S. A.; Yakovleva, S. V.

    1991-05-01

    Presently, it is well known that individual cells"2 and higher organisms3'4 exhibit a marked response to soft laser irradiation in certain parts of the visible and near infrared spectral ranges. Broad clinical applications of laser therapy and slow progress in understanding of the physical, chemical and biological mechanisms of this phenomenon make the task to search new methods of objectivisation of laser-induces bioeffects very insistent. In this paper we give a short review of the methods of structural-optical diagnostics of the soft laser-induced effects in biofluids (blood and its fractions, saliva, juices, mucuses, exudations, etc.) and suggest their applications in experimental and clinical studies of the soft laser bioeffects.

  8. Processing module operating methods, processing modules, and communications systems

    DOEpatents

    McCown, Steven Harvey; Derr, Kurt W.; Moore, Troy

    2014-09-09

    A processing module operating method includes using a processing module physically connected to a wireless communications device, requesting that the wireless communications device retrieve encrypted code from a web site and receiving the encrypted code from the wireless communications device. The wireless communications device is unable to decrypt the encrypted code. The method further includes using the processing module, decrypting the encrypted code, executing the decrypted code, and preventing the wireless communications device from accessing the decrypted code. Another processing module operating method includes using a processing module physically connected to a host device, executing an application within the processing module, allowing the application to exchange user interaction data communicated using a user interface of the host device with the host device, and allowing the application to use the host device as a communications device for exchanging information with a remote device distinct from the host device.

  9. Improved Fermi operator expansion methods for fast electronic structure calculations

    NASA Astrophysics Data System (ADS)

    Liang, WanZhen; Saravanan, Chandra; Shao, Yihan; Baer, Roi; Bell, Alexis T.; Head-Gordon, Martin

    2003-08-01

    Linear scaling algorithms based on Fermi operator expansions (FOE) have been considered significantly slower than other alternative approaches in evaluating the density matrix in Kohn-Sham density functional theory, despite their attractive simplicity. In this work, two new improvements to the FOE method are introduced. First, novel fast summation methods are employed to evaluate a matrix polynomial or Chebyshev matrix polynomial with matrix multiplications totalling roughly twice the square root of the degree of the polynomial. Second, six different representations of the Fermi operators are compared to assess the smallest possible degree of polynomial expansion for a given target precision. The optimal choice appears to be the complementary error function. Together, these advances make the FOE method competitive with the best existing alternatives.

  10. Method of low temperature operation of an electrochemical cell array

    DOEpatents

    Singh, Prabhakar; Ruka, Roswell J.; Bratton, Raymond J.

    1994-01-01

    In the method of operating an electrochemical cell generator apparatus containing a generator chamber (20) containing an array of cells (12) having interior and exterior electrodes with solid electrolyte between the electrodes, where a hot gas (F) contacts the outside of the cells (12) and the generating chamber normally operates at over 850.degree. C., where N.sub.2 gas is fed to contact the interior electrode of the cells (12) in any case when the generating chamber (20) temperature drops for whatever reason to within the range of from 550.degree. C. to 800.degree. C., to eliminate cracking within the cells (12).

  11. Early dental caries detection by method of PNC-diagnostics: comparison with visual and x-ray methods

    NASA Astrophysics Data System (ADS)

    Masychev, Victor I.; Sokolovsky, Alexander A.; Kesler, Gaby; Alexandrov, Michail T.

    2000-03-01

    In this research results of approbation of the optical PNC- method in dental clinic are presented. The PNC-method was used for diagnostics stages of caries (initial, moderate and deep). The variant of the PNC-method adapted for dental diagnosis is based on simultaneous analyses the following parameters by special algorithms: backscattering and probing radiation, stimulated (endogenous) autofluorescence of caries induced batteries. Analyze of informational signals show good correlation with tooth morphological structure and concentration of anaerobic microflora in hearth of caries lesion. Investigation was performed in vivo on 101 tooth in conditions of typical dental clinic. Comparison of the PNC- method with visual and X-ray ones, which are widely used in clinical practice was made. Preliminary results showed high potential of usage the PNC-method in clinical practice and more high probability of initial caries detection (up to 100%) in comparison with X-ray method (approximately 75%). In cases when X-ray diagnosed absence of initial caries, more sensitive the PNC-method detected initial caries in stage 'white lesion.'

  12. Diagnostic methods to cutaneous leishmaniasis detection in domestic dogs and cats*

    PubMed Central

    Trevisan, Daliah Alves Coelho; Lonardoni, Maria Valdrinez Campana; Demarchi, Izabel Galhardo

    2015-01-01

    Cutaneous leishmaniasis is caused by different species of Leishmania. In domestic animals such as dogs and cats, the diagnostic consists of clinical, epidemiological and serological tests, which changes among countries all around the world. Because of this diversity in the methods selected, we propose this systematic literature review to identify the methods of laboratory diagnosis used to detect cutaneous leishmaniasis in domestic dogs and cats in the Americas. Articles published in the last 5 years were searched in PubMed, ISI Web of Science, LILACS and Scielo, and we selected 10 papers about cutaneous leishmaniasis in dogs and cats in the Americas. In Brazil, often the indirect immunofluorescence and enzyme immunoassay (ELISA) have been applied. Other countries like United States and Mexico have been using antigenic fractions for antibodies detections by Western blot. ELISA and Western blot showed a higher sensitivity and efficacy in the detection of leishmaniasis. Analysis of sensibility and specificity of the methods was rarely used. Although confirmatory to leishmaniasis, direct methods for parasites detection and polymerase chain reaction showed low positivity in disease detection. We suggested that more than one method should be used for the detection of feline and canine leishmaniasis. Serological methods such as Western blot and enzyme immunoassay have a high efficacy in the diagnosis of this disease. PMID:26734869

  13. Stability of operator splitting methods for systems with indefinite operators: reaction-diffusion systems

    NASA Astrophysics Data System (ADS)

    Ropp, David L.; Shadid, John N.

    2005-03-01

    In this paper numerical results are reviewed [D.L. Ropp, J.N. Shadid, C.C. Ober, Studies of the accuracy of time integration methods for reaction-diffusion equations, J. Comput. Phys. 194 (2) (2004) 544-574] that demonstrate that common second-order operator-splitting methods can exhibit instabilities when integrating the Brusselator equations out to moderate times of about seven periods of oscillation. These instabilities are manifested as high wave number spatial errors. In this paper, we further analyze this problem, and present a theorem for stability of operator-splitting methods applied to linear reaction-diffusion equations with indefinite reaction terms which controls both low and high wave number instabilities. A corollary shows that if L-stable methods are used for the diffusion term the high wave number instability will be controlled more easily. In the absence of L-stability, an additional time step condition that suppresses the high wave number modes appears to guarantee convergence at the asymptotic order for the operator-splitting method. Numerical results for a model problem confirm this theory, and results for the Brusselator problem agree as well.

  14. MANGO – Modal Analysis for Grid Operation: A Method for Damping Improvement through Operating Point Adjustment

    SciTech Connect

    Huang, Zhenyu; Zhou, Ning; Tuffner, Francis K.; Chen, Yousu; Trudnowski, Daniel J.; Diao, Ruisheng; Fuller, Jason C.; Mittelstadt, William A.; Hauer, John F.; Dagle, Jeffery E.

    2010-10-18

    Small signal stability problems are one of the major threats to grid stability and reliability in the U.S. power grid. An undamped mode can cause large-amplitude oscillations and may result in system breakups and large-scale blackouts. There have been several incidents of system-wide oscillations. Of those incidents, the most notable is the August 10, 1996 western system breakup, a result of undamped system-wide oscillations. Significant efforts have been devoted to monitoring system oscillatory behaviors from measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision, time-synchronized data needed for detecting oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measurements to identify system oscillation modes and their damping. Low damping indicates potential system stability issues. Modal analysis has been demonstrated with phasor measurements to have the capability of estimating system modes from both oscillation signals and ambient data. With more and more phasor measurements available and ModeMeter techniques maturing, there is yet a need for methods to bring modal analysis from monitoring to actions. The methods should be able to associate low damping with grid operating conditions, so operators or automated operation schemes can respond when low damping is observed. The work presented in this report aims to develop such a method and establish a Modal Analysis for Grid Operation (MANGO) procedure to aid grid operation decision making to increase inter-area modal damping. The procedure can provide operation suggestions (such as increasing generation or decreasing load) for mitigating inter-area oscillations.

  15. Holistic Evaluation of Lightweight Operating Systems using the PERCU Method

    SciTech Connect

    Kramer, William T.C.; He, Yun; Carter, Jonathan; Glenski, Joseph; Rippe, Lynn; Cardo, Nicholas

    2008-05-01

    The scale of Leadership Class Systems presents unique challenges to the features and performance of operating system services. This paper reports results of comprehensive evaluations of two Light Weight Operating Systems (LWOS), Cray's Catamount Virtual Node (CVN) and Linux Environment (CLE) operating systems, on the exact same large-scale hardware. The evaluation was carried out over a 5-month period on NERSC's 19,480 core Cray XT-4, Franklin, using a comprehensive evaluation method that spans Performance, Effectiveness, Reliability, Consistency and Usability criteria for all major subsystems and features. The paper presents the results of the comparison between CVN and CLE, evaluates their relative strengths, and reports observations regarding the world's largest Cray XT-4 as well.

  16. Bayesian analysis of two diagnostic methods for paediatric ringworm infections in a teaching hospital.

    PubMed

    Rath, S; Panda, M; Sahu, M C; Padhy, R N

    2015-09-01

    Quantitatively, conventional methods of diagnosis of tinea capitis or paediatric ringworm, microscopic and culture tests were evaluated with Bayes rule. This analysis would help in quantifying the pervasive errors in each diagnostic method, particularly the microscopic method, as a long-term treatment would be involved to eradicate the infection by the use of a particular antifungal chemotherapy. Secondly, the analysis of clinical data would help in obtaining digitally the fallible standard of the microscopic test method, as the culture test method is taken as gold standard. Test results of 51 paediatric patients were of 4 categories: 21 samples were true positive (both tests positive), and 13 were true negative; the rest samples comprised both 14 false positive (microscopic test positivity with culture test negativity) and 3 false negative (microscopic test negativity with culture test positivity) samples. The prevalence of tinea infection was 47.01% in the population of 51 children. The microscopic test of a sample was efficient by 87.5%, in arriving at a positive result on diagnosis, when its culture test was positive; and, this test was efficient by 76.4%, in arriving at a negative result, when its culture test was negative. But, the post-test probability value of a sample with both microscopic and culture tests would be correct in distinguishing a sample from a sick or a healthy child with a chance of 71.5%. However, since the sensitivity of the analysis is 87.5%, the microscopic test positivity would be easier to detect in the presence of infection. In conclusion, it could be stated that Trychophyton rubrum was the most prevalent species; sensitivity and specificity of treating the infection, by antifungal therapy before ascertaining by the culture method remain as 0.8751 and 0.7642, respectively. A correct/coveted diagnostic method of fungal infection would be could be achieved by modern molecular methods (matrix-assisted laser desorption ionisation

  17. Method and apparatus to predict the remaining service life of an operating system

    DOEpatents

    Greitzer, Frank L.; Kangas, Lars J.; Terrones, Kristine M.; Maynard, Melody A.; Pawlowski, Ronald A. , Ferryman; Thomas A.; Skorpik, James R.; Wilson, Bary W.

    2008-11-25

    A method and computer-based apparatus for monitoring the degradation of, predicting the remaining service life of, and/or planning maintenance for, an operating system are disclosed. Diagnostic information on degradation of the operating system is obtained through measurement of one or more performance characteristics by one or more sensors onboard and/or proximate the operating system. Though not required, it is preferred that the sensor data are validated to improve the accuracy and reliability of the service life predictions. The condition or degree of degradation of the operating system is presented to a user by way of one or more calculated, numeric degradation figures of merit that are trended against one or more independent variables using one or more mathematical techniques. Furthermore, more than one trendline and uncertainty interval may be generated for a given degradation figure of merit/independent variable data set. The trendline(s) and uncertainty interval(s) are subsequently compared to one or more degradation figure of merit thresholds to predict the remaining service life of the operating system. The present invention enables multiple mathematical approaches in determining which trendline(s) to use to provide the best estimate of the remaining service life.

  18. Problems with the differential receiver operating characteristic (DROC) method

    NASA Astrophysics Data System (ADS)

    Chakraborty, Dev P.

    2004-05-01

    Most papers in these proceedings present ideas that work. This is the story of an idea that did not work as intended. The differential receiver operating characteristic (DROC) method was proposed about 8 years ago. It was intended to measure the difference in performance between two imaging modalities. It was expected that the DROC method could outperform the ROC method in statistical power. This expectation has not been borne out and the author no longer recommends the DROC method. The purpose of this paper is to present a critical look at this method, why the author initially believed it should work, the assumptions involved and the fallacies. The author believes there is value to this frank account as it has yielded, at least for the author, new insights into ROC analysis. The author concludes with a few personal reflections on his experience with this project and advice on how to deal with negative results.

  19. Improving Cognitive Diagnostic Computerized Adaptive Testing by Balancing Attribute Coverage: The Modified Maximum Global Discrimination Index Method

    ERIC Educational Resources Information Center

    Cheng, Ying

    2010-01-01

    This article proposes a new item selection method, namely, the modified maximum global discrimination index (MMGDI) method, for cognitive diagnostic computerized adaptive testing (CD-CAT). The new method captures two aspects of the appeal of an item: (a) the amount of contribution it can make toward adequate coverage of every attribute and (b) the…

  20. Computer controlled fluorometer device and method of operating same

    DOEpatents

    Kolber, Zbigniew; Falkowski, Paul

    1990-01-01

    A computer controlled fluorometer device and method of operating same, said device being made to include a pump flash source and a probe flash source and one or more sample chambers in combination with a light condenser lens system and associated filters and reflectors and collimators, as well as signal conditioning and monitoring means and a programmable computer means and a software programmable source of background irradiance that is operable according to the method of the invention to rapidly, efficiently and accurately measure photosynthetic activity by precisely monitoring and recording changes in fluorescence yield produced by a controlled series of predetermined cycles of probe and pump flashes from the respective probe and pump sources that are controlled by the computer means.

  1. The methods of decrease operating pressure of fast neutrals source

    NASA Astrophysics Data System (ADS)

    Barchenko, V. T.; Komlev, A. E.; Babinov, N. A.; Vinogradov, M. L.

    2015-11-01

    The fast neutral particles sources are more and more widely used in technologies of surface processing and coatings deposition, especially in the case of dielectric surfaces processing. However for substantial expansion of the sources applications scope it is necessary to decrease the pressure in the vacuum chamber at which they can operate. This article describes the methods to reduce the operating pressure of the fast neutral particles source with combined ions acceleration and its neutralization regions. This combination provide a total absence of the high-energy ions in the particles beam. The main discussed methods are creation of pressure drop between internal and external volumes of the source and working gas preionization which is provided by combustion of auxiliary gas discharge.

  2. Computer controlled fluorometer device and method of operating same

    DOEpatents

    Kolber, Z.; Falkowski, P.

    1990-07-17

    A computer controlled fluorometer device and method of operating same, said device being made to include a pump flash source and a probe flash source and one or more sample chambers in combination with a light condenser lens system and associated filters and reflectors and collimators, as well as signal conditioning and monitoring means and a programmable computer means and a software programmable source of background irradiance that is operable according to the method of the invention to rapidly, efficiently and accurately measure photosynthetic activity by precisely monitoring and recording changes in fluorescence yield produced by a controlled series of predetermined cycles of probe and pump flashes from the respective probe and pump sources that are controlled by the computer means. 13 figs.

  3. [Successful surgical management of aortico-left ventricular tunnel using modern noninvasive diagnostic imaging methods].

    PubMed

    Hartyánszky, István; Katona, Márta; Kádár, Krisztina; Apor, Asztrid; Varga, Sándor; Simon, Judit; Tóth, Attila; Karácsony, Tünde; Bogáts, Gábor

    2015-07-12

    Aortico-left ventricular tunnel is a rare congenital cardiac defect, which bypasses the aortic valve via the paravalvar connection from the aorta to the left ventricle. The authors present the case of a 14-year-old boy with aortico-left ventricular tunnel in whom the aortic orifice arose from the right aortic sinus and was closed by a pericardial patch. The diagnosis was confirmed by combined two-dimensional and real time three-dimensional echocardiogram and magnetic resonance imaging. This is the first case, in which these complex diagnostic imaging methods have been used in the pre- and postoperative management of this defect. Optimally the new transthoratic three-dimensional echocardiography would be needed to define the anatomy and functional consequences of the aortico-left ventricular tunnel and in the postoperative follow-up.

  4. Embedded diagnostic, prognostic, and health management system and method for a humanoid robot

    NASA Technical Reports Server (NTRS)

    Barajas, Leandro G. (Inventor); Sanders, Adam M (Inventor); Reiland, Matthew J (Inventor); Strawser, Philip A (Inventor)

    2013-01-01

    A robotic system includes a humanoid robot with multiple compliant joints, each moveable using one or more of the actuators, and having sensors for measuring control and feedback data. A distributed controller controls the joints and other integrated system components over multiple high-speed communication networks. Diagnostic, prognostic, and health management (DPHM) modules are embedded within the robot at the various control levels. Each DPHM module measures, controls, and records DPHM data for the respective control level/connected device in a location that is accessible over the networks or via an external device. A method of controlling the robot includes embedding a plurality of the DPHM modules within multiple control levels of the distributed controller, using the DPHM modules to measure DPHM data within each of the control levels, and recording the DPHM data in a location that is accessible over at least one of the high-speed communication networks.

  5. Microvascular resistance in essential hypertension and flowmetry as a diagnostic method

    NASA Astrophysics Data System (ADS)

    Lukjanov, Valdimir F.

    2001-08-01

    New Doppler-Laser flowmetry diagnostic test of functional condition of microcirculation was worked out of find precapillar and postcapillar resistance. Flowmetry was used to measure vasomotion and blood flow after arterial compression, decompression and venous hyperemia were held. Patients of essential hypertension were examined with the help of Doppler-Laser Flowmetry, optical photometry (540 nm). Precapillar resistance included next basis parameters: vasomotion with high frequency (10-16 per/min) and low amplitude, latent time after decompression, large postocclusive reactive hyperemia, absent venous hyperemia. Postcapillar resistance included next basis parameters: vasomotion with low frequency (4-8 per/min) and high amplitude, paradoxical hyperemia in arterial compression, little or absent postocclusive reactive hyperemia, large venous hyperemia. This test-method was applied to select patogenetic treatment of essential hypertension.

  6. [On the method of express-diagnostics of thyroid gland dysfunctions].

    PubMed

    Abazova, Z Kh; Baĭsiev, A Kh; Kumykov, V K; Efendieva, M K

    2005-01-01

    The method of express-diagnostics of thyroid diseases on a degree of moisture of the skin integument which is one of clinical attributes of hypothyroidism (a skin is dry, shelled, with sites of keratinization) and hyperthyroidism at which the return picture is observed, i.e. the (increased humidity of a skin is offered. At the same time as a parameter describing a degree of moisture of skin is a relative humidity of the air environment which are taking place above the skin integument in conditions of thermodynamic equilibrium. The instrument is a hermetic glass in which the sensor of humidity is mounted. Studies on the definition of threshold levels of parameter for several groups of patients with clinically confirmed diagnoses of diseases of a thyroid are carried out. PMID:16106951

  7. The Scientific Method, Diagnostic Bayes, and How to Detect Epistemic Errors

    NASA Astrophysics Data System (ADS)

    Vrugt, J. A.

    2015-12-01

    In the past decades, Bayesian methods have found widespread application and use in environmental systems modeling. Bayes theorem states that the posterior probability, P(H|D) of a hypothesis, H is proportional to the product of the prior probability, P(H) of this hypothesis and the likelihood, L(H|hat{D}) of the same hypothesis given the new/incoming observations, \\hat {D}. In science and engineering, H often constitutes some numerical simulation model, D = F(x,.) which summarizes using algebraic, empirical, and differential equations, state variables and fluxes, all our theoretical and/or practical knowledge of the system of interest, and x are the d unknown parameters which are subject to inference using some data, \\hat {D} of the observed system response. The Bayesian approach is intimately related to the scientific method and uses an iterative cycle of hypothesis formulation (model), experimentation and data collection, and theory/hypothesis refinement to elucidate the rules that govern the natural world. Unfortunately, model refinement has proven to be very difficult in large part because of the poor diagnostic power of residual based likelihood functions tep{gupta2008}. This has inspired te{vrugt2013} to advocate the use of 'likelihood-free' inference using approximate Bayesian computation (ABC). This approach uses one or more summary statistics, S(\\hat {D}) of the original data, \\hat {D} designed ideally to be sensitive only to one particular process in the model. Any mismatch between the observed and simulated summary metrics is then easily linked to a specific model component. A recurrent issue with the application of ABC is self-sufficiency of the summary statistics. In theory, S(.) should contain as much information as the original data itself, yet complex systems rarely admit sufficient statistics. In this article, we propose to combine the ideas of ABC and regular Bayesian inference to guarantee that no information is lost in diagnostic model

  8. Methods of Controlling the Loop Heat Pipe Operating Temperature

    NASA Technical Reports Server (NTRS)

    Ku, Jentung

    2008-01-01

    The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the amount of heat exchanged between the CC and ambient. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. The most common method is to cold bias the CC and use electric heater power to maintain the CC set point temperature. The required electric heater power can be large when the condenser sink is very cold. Several methods have been developed to reduce the control heater power, including coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, by-pass valve with pressure regulator, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.

  9. Article separation apparatus and method for unit operations

    DOEpatents

    Pardini, Allan F.; Gervais, Kevin L.; Mathews, Royce A.; Hockey, Ronald L.

    2010-06-22

    An apparatus and method are disclosed for separating articles from a group of articles. The apparatus includes a container for containing one or more articles coupled to a suitable fluidizer for suspending articles within the container and transporting articles to an induction tube. A portal in the induction tube introduces articles singly into the induction tube. A vacuum pulls articles through the induction tube separating the articles from the group of articles in the container. The apparatus and method can be combined with one or more unit operations or modules, e.g., for inspecting articles, assessing quality of articles, or ascertaining material properties and/or parameters of articles, including layers thereof.

  10. A new method for tracking organ motion on diagnostic ultrasound images

    SciTech Connect

    Kubota, Yoshiki Matsumura, Akihiko; Fukahori, Mai; Minohara, Shin-ichi; Yasuda, Shigeo; Nagahashi, Hiroshi

    2014-09-15

    Purpose: Respiratory-gated irradiation is effective in reducing the margins of a target in the case of abdominal organs, such as the liver, that change their position as a result of respiratory motion. However, existing technologies are incapable of directly measuring organ motion in real-time during radiation beam delivery. Hence, the authors proposed a novel quantitative organ motion tracking method involving the use of diagnostic ultrasound images; it is noninvasive and does not entail radiation exposure. In the present study, the authors have prospectively evaluated this proposed method. Methods: The method involved real-time processing of clinical ultrasound imaging data rather than organ monitoring; it comprised a three-dimensional ultrasound device, a respiratory sensing system, and two PCs for data storage and analysis. The study was designed to evaluate the effectiveness of the proposed method by tracking the gallbladder in one subject and a liver vein in another subject. To track a moving target organ, the method involved the control of a region of interest (ROI) that delineated the target. A tracking algorithm was used to control the ROI, and a large number of feature points and an error correction algorithm were used to achieve long-term tracking of the target. Tracking accuracy was assessed in terms of how well the ROI matched the center of the target. Results: The effectiveness of using a large number of feature points and the error correction algorithm in the proposed method was verified by comparing it with two simple tracking methods. The ROI could capture the center of the target for about 5 min in a cross-sectional image with changing position. Indeed, using the proposed method, it was possible to accurately track a target with a center deviation of 1.54 ± 0.9 mm. The computing time for one frame image using our proposed method was 8 ms. It is expected that it would be possible to track any soft-tissue organ or tumor with large deformations and

  11. Differential operator multiplication method for fractional differential equations

    NASA Astrophysics Data System (ADS)

    Tang, Shaoqiang; Ying, Yuping; Lian, Yanping; Lin, Stephen; Yang, Yibo; Wagner, Gregory J.; Liu, Wing Kam

    2016-11-01

    Fractional derivatives play a very important role in modeling physical phenomena involving long-range correlation effects. However, they raise challenges of computational cost and memory storage requirements when solved using current well developed numerical methods. In this paper, the differential operator multiplication method is proposed to address the issues by considering a reaction-advection-diffusion equation with a fractional derivative in time. The linear fractional differential equation is transformed into an integer order differential equation by the proposed method, which can fundamentally fix the aforementioned issues for select fractional differential equations. In such a transform, special attention should be paid to the initial conditions for the resulting differential equation of higher integer order. Through numerical experiments, we verify the proposed method for both fractional ordinary differential equations and partial differential equations.

  12. Differential operator multiplication method for fractional differential equations

    NASA Astrophysics Data System (ADS)

    Tang, Shaoqiang; Ying, Yuping; Lian, Yanping; Lin, Stephen; Yang, Yibo; Wagner, Gregory J.; Liu, Wing Kam

    2016-08-01

    Fractional derivatives play a very important role in modeling physical phenomena involving long-range correlation effects. However, they raise challenges of computational cost and memory storage requirements when solved using current well developed numerical methods. In this paper, the differential operator multiplication method is proposed to address the issues by considering a reaction-advection-diffusion equation with a fractional derivative in time. The linear fractional differential equation is transformed into an integer order differential equation by the proposed method, which can fundamentally fix the aforementioned issues for select fractional differential equations. In such a transform, special attention should be paid to the initial conditions for the resulting differential equation of higher integer order. Through numerical experiments, we verify the proposed method for both fractional ordinary differential equations and partial differential equations.

  13. Hybrid digital signal processing and neural networks for automated diagnostics using NDE methods

    SciTech Connect

    Upadhyaya, B.R.; Yan, W.

    1993-11-01

    The primary purpose of the current research was to develop an integrated approach by combining information compression methods and artificial neural networks for the monitoring of plant components using nondestructive examination data. Specifically, data from eddy current inspection of heat exchanger tubing were utilized to evaluate this technology. The focus of the research was to develop and test various data compression methods (for eddy current data) and the performance of different neural network paradigms for defect classification and defect parameter estimation. Feedforward, fully-connected neural networks, that use the back-propagation algorithm for network training, were implemented for defect classification and defect parameter estimation using a modular network architecture. A large eddy current tube inspection database was acquired from the Metals and Ceramics Division of ORNL. These data were used to study the performance of artificial neural networks for defect type classification and for estimating defect parameters. A PC-based data preprocessing and display program was also developed as part of an expert system for data management and decision making. The results of the analysis showed that for effective (low-error) defect classification and estimation of parameters, it is necessary to identify proper feature vectors using different data representation methods. The integration of data compression and artificial neural networks for information processing was established as an effective technique for automation of diagnostics using nondestructive examination methods.

  14. Diagnostic Methods of Helicobacter pylori Infection for Epidemiological Studies: Critical Importance of Indirect Test Validation

    PubMed Central

    Miftahussurur, Muhammad; Yamaoka, Yoshio

    2016-01-01

    Among the methods developed to detect H. pylori infection, determining the gold standard remains debatable, especially for epidemiological studies. Due to the decreasing sensitivity of direct diagnostic tests (histopathology and/or immunohistochemistry [IHC], rapid urease test [RUT], and culture), several indirect tests, including antibody-based tests (serology and urine test), urea breath test (UBT), and stool antigen test (SAT) have been developed to diagnose H. pylori infection. Among the indirect tests, UBT and SAT became the best methods to determine active infection. While antibody-based tests, especially serology, are widely available and relatively sensitive, their specificity is low. Guidelines indicated that no single test can be considered as the gold standard for the diagnosis of H. pylori infection and that one should consider the method's advantages and disadvantages. Based on four epidemiological studies, culture and RUT present a sensitivity of 74.2–90.8% and 83.3–86.9% and a specificity of 97.7–98.8% and 95.1–97.2%, respectively, when using IHC as a gold standard. The sensitivity of serology is quite high, but that of the urine test was lower compared with that of the other methods. Thus, indirect test validation is important although some commercial kits propose universal cut-off values. PMID:26904678

  15. [Mass spectrometry analysis of blood plasma lipidome as method of disease diagnostics, evuation of effectiveness and optimization of drug therapy].

    PubMed

    Lokhov, P G; Maslov, D L; Balashova, E E; Trifonova, O P; Medvedeva, N V; Torkhovskaya, T I; Ipatova, O M; Archakov, A I; Malyshev, P P; Kukharchuk, V V; Shestakova, E A; Shestakova, M V; Dedov, I I

    2015-01-01

    A new method for the analysis of blood lipid based on direct mass spectrometry of lipophilic low molecular weight fraction of blood plasma has been considered. Such technique allows quantification of hundreds of various types of lipids and this changes existing concepts on diagnostics of lipid disorders and related diseases. The versatility and quickness of the method significantly simplify its wide use. This method is applicable for diagnostics of atherosclerosis, diabetes, cancer and other diseases. Detalization of plasma lipid composition at the molecular level by means of mass spectrometry allows to assess the effectiveness of therapy and to optimize the drug treatment of cardiovascular diseases by phospholipid preparations.

  16. Method and apparatus for operating an improved thermocline storage unit

    DOEpatents

    Copeland, Robert J.

    1985-01-01

    A method and apparatus for operating a thermocline storage unit in which an insulated barrier member is provided substantially at the interface region between the hot and cold liquids in the storage tank. The barrier member physically and thermally separates the hot and cold liquids substantially preventing any diffusing or mixing between them and substantially preventing any heat transfer therebetween. The barrier member follows the rise and fall of the interface region between the liquids as the tank is charged and discharged. Two methods of maintaining it in the interface region are disclosed. With the structure and operation of the present invention and in particular the significant reduction in diffusing or mixing between the hot and cold liquids as well as the significant reduction in the thermal heat transfer between them, the performance of the storage tank is improved. More specifically, the stability of the interface region or thermocline is enhanced and the thickness of the thermocline is reduced producing a corresponding increase in the steepness of the temperature gradient across the thermocline and a more efficiently operating thermocline storage unit.

  17. Method and apparatus for operating an improved thermocline storage unit

    DOEpatents

    Copeland, R.J.

    1982-09-30

    A method and apparatus for operating a thermocline storage unit in which an insulated barrier member is provided substantially at the interface region between the hot and cold liquids in the storage tank. The barrier member physically and thermally separates the hot and cold liquids substantially preventing any diffusing or mixing between them and substantially preventing any heat transfer there between. The barrier member follows the rise and fall of the interface region between the liquids as the tank is charged and discharged. Two methods of maintaining it in the interface region are disclosed. With the structure and operation of the present invention and in particular the significant reduction in diffusing or mixing between the hot and cold liquids as well as the significant reduction in the thermal heat transfer between them, the performance of the storage tank is improved. More specifically, the stability of the interface region or thermocline is enhanced and the thickness of the thermocline is reduced producing a corresponding increase in the steepness of the temperature gradient across the thermocline and a more efficiently operating thermocline storage unit.

  18. Diagnostic methods of a bladed disc mode shape evaluation used for shrouded blades in steam turbines

    NASA Astrophysics Data System (ADS)

    Strnad, Jaromir; Liska, Jindrich

    2015-11-01

    This paper deals with advanced methods for the evaluation of a bladed disc behavior in terms of the wheel vibration and blade service time consumption. These methods are developed as parts of the noncontact vibration monitoring system of the steam turbine shrouded blades. The proposed methods utilize the time-frequency processing (cross spectra) and the method using least squares to analyse the data from the optical and magnetoresistive sensors, which are mounted in the stator radially above the rotor blades. Fundamentally, the blade vibrations are detected during the blade passages under the sensors and the following signal processing, which covers also the proposed methods, leads to the estimation of the blade residual service life. The prototype system implementing above mentioned techniques was installed into the last stage of the new steam turbine (LP part). The methods for bladed disc mode shape evaluation were successfully verified on the signals, which were obtained during the commission operation of the turbine.

  19. Mathematical methods to assist with hospital operation and planning.

    PubMed

    Gallivan, Steve

    2005-12-01

    Within health Operational Research, the use of 'computer package' methods such as simulation and system dynamics is becoming so prevalent that it feels somewhat old hat to use analytical methods to develop explicit mathematical formulae or even to explore the mathematical structure of problems. This paper will discuss the use of such 'back of the envelope' analysis illustrating its usefulness. It will be shown that not only does this approach yield considerable insight, but also that it can give rise to powerful and practical solution methods. Examples of this will be discussed in relation to issues such as bed needs estimation, admissions and facilities planning. The author is Director of the Clinical Operational Research Unit (CORU) which was established in 1983, receiving core funding from the UK Department of Health. The concept of a full time university-based research unit dedicated to applying expertise in Operational Research (OR) to problems in health care provides a relatively rare research resource. Yet, the scope for such research, applied to an increasing range of health care activity, is enormous. Issues such as treatment evaluation, performance measures, clinical governance, evidence based medicine and health service delivery are all amenable to OR. Further, OR often provides an immensely cost effective alternative to traditional methods of clinical research based on randomised controlled trials or large scale epidemiological studies. The nature of OR, and one of its main strengths, is that it encompasses a wide range of analytical and scientific methods. Mathematical modeling, statistics, computer-based methods, trial design and analysis all contribute to health OR and, under both of its Directors since 1983, a conscious effort has been made within CORU to foster a diversity of research methodologies. Particular emphasis is put on developing new mathematical methods and computer software. This is somewhat at odds with what seems to be a growing trend

  20. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network

    PubMed Central

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-01

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method. PMID:26761006

  1. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network.

    PubMed

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-01

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method.

  2. Intelligent Condition Diagnosis Method Based on Adaptive Statistic Test Filter and Diagnostic Bayesian Network.

    PubMed

    Li, Ke; Zhang, Qiuju; Wang, Kun; Chen, Peng; Wang, Huaqing

    2016-01-01

    A new fault diagnosis method for rotating machinery based on adaptive statistic test filter (ASTF) and Diagnostic Bayesian Network (DBN) is presented in this paper. ASTF is proposed to obtain weak fault features under background noise, ASTF is based on statistic hypothesis testing in the frequency domain to evaluate similarity between reference signal (noise signal) and original signal, and remove the component of high similarity. The optimal level of significance α is obtained using particle swarm optimization (PSO). To evaluate the performance of the ASTF, evaluation factor Ipq is also defined. In addition, a simulation experiment is designed to verify the effectiveness and robustness of ASTF. A sensitive evaluation method using principal component analysis (PCA) is proposed to evaluate the sensitiveness of symptom parameters (SPs) for condition diagnosis. By this way, the good SPs that have high sensitiveness for condition diagnosis can be selected. A three-layer DBN is developed to identify condition of rotation machinery based on the Bayesian Belief Network (BBN) theory. Condition diagnosis experiment for rolling element bearings demonstrates the effectiveness of the proposed method. PMID:26761006

  3. Comparison of diagnostic methods in cutaneous Leishmaniasis (histopathology compared to skin smears).

    PubMed

    Gazozai, Sanaullah; Iqbal, Javeid; Bukhari, Ishrat; Bashir, Sajid

    2010-10-01

    Present study is carried out to compare laboratory diagnostic methods of Cutaneous leishmaniasis (CL) for the outdoor patients of Bolan Medical College Complex Hospital, Quetta, Balochistan. From November 2005 to December 2007, three hundred cases of CL patients were selected without restriction of age and sex. The lesions were divided into two groups. Early with duration less than 2 months and late duration between 2 to 4 months and were noted as nodules, plaques, ulcers and scarring (in case of relapses). Skin smears were taken on first visit of the patients, followed by skin biopsy for histopathological examination. Result showed that out of 300 cases 163 (54.33%) were positive smears for Leishmania donovani (LD) bodies and 137 (45.67%) were negative smears for LD bodies.. While histological examination of all 300 cases showed that only 83 (27.66%) cases were negative for (LD) bodies and no granuloma seen, except with evidence of acute and chronic inflammation. Further analysis of histological observations of positive cases (72.34%) revealed that 91(30.33%) cases had LD bodies,, 78 (26%) cases had only necrotic sloughs showing polymorph neutrophilic infiltration, and 48(16%) cases were having granulomas composed of, epithelioid cells Langhan's type of giant cells and lymphocytes. It is therefore concluded that histopathological examination as compared to skin smears method is more sensitive method for diagnosis of CL.

  4. Multicenter Evaluation of Clinical Diagnostic Methods for Detection and Isolation of Campylobacter spp. from Stool.

    PubMed

    Fitzgerald, Collette; Patrick, Mary; Gonzalez, Anthony; Akin, Joshua; Polage, Christopher R; Wymore, Kate; Gillim-Ross, Laura; Xavier, Karen; Sadlowski, Jennifer; Monahan, Jan; Hurd, Sharon; Dahlberg, Suzanne; Jerris, Robert; Watson, Renee; Santovenia, Monica; Mitchell, David; Harrison, Cassandra; Tobin-D'Angelo, Melissa; DeMartino, Mary; Pentella, Michael; Razeq, Jafar; Leonard, Celere; Jung, Carrianne; Achong-Bowe, Ria; Evans, Yaaqobah; Jain, Damini; Juni, Billie; Leano, Fe; Robinson, Trisha; Smith, Kirk; Gittelman, Rachel M; Garrigan, Charles; Nachamkin, Irving

    2016-05-01

    The use of culture-independent diagnostic tests (CIDTs), such as stool antigen tests, as standalone tests for the detection of Campylobacter in stool is increasing. We conducted a prospective, multicenter study to evaluate the performance of stool antigen CIDTs compared to culture and PCR for Campylobacter detection. Between July and October 2010, we tested 2,767 stool specimens from patients with gastrointestinal illness with the following methods: four types of Campylobacter selective media, four commercial stool antigen assays, and a commercial PCR assay. Illnesses from which specimens were positive by one or more culture media or at least one CIDT and PCR were designated "cases." A total of 95 specimens (3.4%) met the case definition. The stool antigen CIDTs ranged from 79.6% to 87.6% in sensitivity, 95.9 to 99.5% in specificity, and 41.3 to 84.3% in positive predictive value. Culture alone detected 80/89 (89.9% sensitivity) Campylobacter jejuni/Campylobacter coli-positive cases. Of the 209 noncases that were positive by at least one CIDT, only one (0.48%) was positive by all four stool antigen tests, and 73% were positive by just one stool antigen test. The questionable relevance of unconfirmed positive stool antigen CIDT results was supported by the finding that noncases were less likely than cases to have gastrointestinal symptoms. Thus, while the tests were convenient to use, the sensitivity, specificity, and positive predictive value of Campylobacter stool antigen tests were highly variable. Given the relatively low incidence of Campylobacter disease and the generally poor diagnostic test characteristics, this study calls into question the use of commercially available stool antigen CIDTs as standalone tests for direct detection of Campylobacter in stool.

  5. HEART Pathway Accelerated Diagnostic Protocol Implementation: Prospective Pre-Post Interrupted Time Series Design and Methods

    PubMed Central

    Wells, Brian J

    2016-01-01

    Background Most patients presenting to US Emergency Departments (ED) with chest pain are hospitalized for comprehensive testing. These evaluations cost the US health system >$10 billion annually, but have a diagnostic yield for acute coronary syndrome (ACS) of <10%. The history/ECG/age/risk factors/troponin (HEART) Pathway is an accelerated diagnostic protocol (ADP), designed to improve care for patients with acute chest pain by identifying patients for early ED discharge. Prior efficacy studies demonstrate that the HEART Pathway safely reduces cardiac testing, while maintaining an acceptably low adverse event rate. Objective The purpose of this study is to determine the effectiveness of HEART Pathway ADP implementation within a health system. Methods This controlled before-after study will accrue adult patients with acute chest pain, but without ST-segment elevation myocardial infarction on electrocardiogram for two years and is expected to include approximately 10,000 patients. Outcomes measures include hospitalization rate, objective cardiac testing rates (stress testing and angiography), length of stay, and rates of recurrent cardiac care for participants. Results In pilot data, the HEART Pathway decreased hospitalizations by 21%, decreased hospital length (median of 12 hour reduction), without increasing adverse events or recurrent care. At the writing of this paper, data has been collected on >5000 patient encounters. The HEART Pathway has been fully integrated into health system electronic medical records, providing real-time decision support to our providers. Conclusions We hypothesize that the HEART Pathway will safely reduce healthcare utilization. This study could provide a model for delivering high-value care to the 8-10 million US ED patients with acute chest pain each year. ClinicalTrial Clinicaltrials.gov NCT02056964; https://clinicaltrials.gov/ct2/show/NCT02056964 (Archived by WebCite at http://www.webcitation.org/6ccajsgyu) PMID:26800789

  6. Multicenter Evaluation of Clinical Diagnostic Methods for Detection and Isolation of Campylobacter spp. from Stool.

    PubMed

    Fitzgerald, Collette; Patrick, Mary; Gonzalez, Anthony; Akin, Joshua; Polage, Christopher R; Wymore, Kate; Gillim-Ross, Laura; Xavier, Karen; Sadlowski, Jennifer; Monahan, Jan; Hurd, Sharon; Dahlberg, Suzanne; Jerris, Robert; Watson, Renee; Santovenia, Monica; Mitchell, David; Harrison, Cassandra; Tobin-D'Angelo, Melissa; DeMartino, Mary; Pentella, Michael; Razeq, Jafar; Leonard, Celere; Jung, Carrianne; Achong-Bowe, Ria; Evans, Yaaqobah; Jain, Damini; Juni, Billie; Leano, Fe; Robinson, Trisha; Smith, Kirk; Gittelman, Rachel M; Garrigan, Charles; Nachamkin, Irving

    2016-05-01

    The use of culture-independent diagnostic tests (CIDTs), such as stool antigen tests, as standalone tests for the detection of Campylobacter in stool is increasing. We conducted a prospective, multicenter study to evaluate the performance of stool antigen CIDTs compared to culture and PCR for Campylobacter detection. Between July and October 2010, we tested 2,767 stool specimens from patients with gastrointestinal illness with the following methods: four types of Campylobacter selective media, four commercial stool antigen assays, and a commercial PCR assay. Illnesses from which specimens were positive by one or more culture media or at least one CIDT and PCR were designated "cases." A total of 95 specimens (3.4%) met the case definition. The stool antigen CIDTs ranged from 79.6% to 87.6% in sensitivity, 95.9 to 99.5% in specificity, and 41.3 to 84.3% in positive predictive value. Culture alone detected 80/89 (89.9% sensitivity) Campylobacter jejuni/Campylobacter coli-positive cases. Of the 209 noncases that were positive by at least one CIDT, only one (0.48%) was positive by all four stool antigen tests, and 73% were positive by just one stool antigen test. The questionable relevance of unconfirmed positive stool antigen CIDT results was supported by the finding that noncases were less likely than cases to have gastrointestinal symptoms. Thus, while the tests were convenient to use, the sensitivity, specificity, and positive predictive value of Campylobacter stool antigen tests were highly variable. Given the relatively low incidence of Campylobacter disease and the generally poor diagnostic test characteristics, this study calls into question the use of commercially available stool antigen CIDTs as standalone tests for direct detection of Campylobacter in stool. PMID:26962088

  7. Computer-aided diagnostic method for classification of Alzheimer's disease with atrophic image features on MR images

    NASA Astrophysics Data System (ADS)

    Arimura, Hidetaka; Yoshiura, Takashi; Kumazawa, Seiji; Tanaka, Kazuhiro; Koga, Hiroshi; Mihara, Futoshi; Honda, Hiroshi; Sakai, Shuji; Toyofuku, Fukai; Higashida, Yoshiharu

    2008-03-01

    Our goal for this study was to attempt to develop a computer-aided diagnostic (CAD) method for classification of Alzheimer's disease (AD) with atrophic image features derived from specific anatomical regions in three-dimensional (3-D) T1-weighted magnetic resonance (MR) images. Specific regions related to the cerebral atrophy of AD were white matter and gray matter regions, and CSF regions in this study. Cerebral cortical gray matter regions were determined by extracting a brain and white matter regions based on a level set based method, whose speed function depended on gradient vectors in an original image and pixel values in grown regions. The CSF regions in cerebral sulci and lateral ventricles were extracted by wrapping the brain tightly with a zero level set determined from a level set function. Volumes of the specific regions and the cortical thickness were determined as atrophic image features. Average cortical thickness was calculated in 32 subregions, which were obtained by dividing each brain region. Finally, AD patients were classified by using a support vector machine, which was trained by the image features of AD and non-AD cases. We applied our CAD method to MR images of whole brains obtained from 29 clinically diagnosed AD cases and 25 non-AD cases. As a result, the area under a receiver operating characteristic (ROC) curve obtained by our computerized method was 0.901 based on a leave-one-out test in identification of AD cases among 54 cases including 8 AD patients at early stages. The accuracy for discrimination between 29 AD patients and 25 non-AD subjects was 0.840, which was determined at the point where the sensitivity was the same as the specificity on the ROC curve. This result showed that our CAD method based on atrophic image features may be promising for detecting AD patients by using 3-D MR images.

  8. Methods for Determining Operation Lifetime of Space Reactors

    SciTech Connect

    Schriener, Timothy M.; El-Genk, Mohamed S.

    2007-01-30

    Space fission reactors can provide reliable, high power levels for periods of more than 10 years to support human outposts and for space travel to the farthest planets in the solar system. The operation lifetimes of these reactors depend on many factors chief among which are the hot-clean excess reactivity and the fuel burnup rate (or operation power) and the accumulation and decay of fission products. Other important parameters are the fuel average temperature and fissile inventory and the Doppler reactivity effect. Determining the operation lifetime for space reactors is a critical input to mission planning, requiring the use of sophisticated fuel burnup and criticality computational tools and benchmarking the results against actual data, if readily available. This paper performs parametric and comparative studies using widely used codes and a simplified approach for determining the operation lifetimes of two space reactors: the Sectored, Compact Reactor (SCoRe) that is liquid metal cooled, and the Submersion-Subcritical, Safe Space (S and 4) reactor that is cooled by a He-Xe binary gas mixture. The codes investigated against experimental data from a LWR are: (a) Monteburns 2.0, coupling MCNP5 1.30 to Origen2.2, (b) MCNPX 2.6b's internal burn package incorporating CINDER90, and (c) TRITON a code in the SCALE5 package using NEWT and Origen-S. From the results Monteburns and MCNPX performed the best, and are selected to compare their predictions of the lifetimes of the two space reactors with those of a simplified method. This method couples MCNP5 to a burnup analysis model in Simulink registered considering only the 10 most probable low Z and 10 most probable high Z elements of the fission yield peaks plus 149Sm. Results show that the predicted operational lifetimes using the simplified method are within -6.6 to 12.8% of those calculated using the widely used Monteburns 2.0 and MCNPX 2.6bc1 codes.

  9. Methods for Determining Operation Lifetime of Space Reactors

    NASA Astrophysics Data System (ADS)

    Schriener, Timothy M.; El-Genk, Mohamed S.

    2007-01-01

    Space fission reactors can provide reliable, high power levels for periods of more than 10 years to support human outposts and for space travel to the farthest planets in the solar system. The operation lifetimes of these reactors depend on many factors chief among which are the hot-clean excess reactivity and the fuel burnup rate (or operation power) and the accumulation and decay of fission products. Other important parameters are the fuel average temperature and fissile inventory and the Doppler reactivity effect. Determining the operation lifetime for space reactors is a critical input to mission planning, requiring the use of sophisticated fuel burnup and criticality computational tools and benchmarking the results against actual data, if readily available. This paper performs parametric and comparative studies using widely used codes and a simplified approach for determining the operation lifetimes of two space reactors: the Sectored, Compact Reactor (SCoRe) that is liquid metal cooled, and the Submersion-Subcritical, Safe Space (S∧4) reactor that is cooled by a He-Xe binary gas mixture. The codes investigated against experimental data from a LWR are: (a) Monteburns 2.0, coupling MCNP5 1.30 to Origen2.2, (b) MCNPX 2.6b's internal burn package incorporating CINDER90, and (c) TRITON a code in the SCALE5 package using NEWT and Origen-S. From the results Monteburns and MCNPX performed the best, and are selected to compare their predictions of the lifetimes of the two space reactors with those of a simplified method. This method couples MCNP5 to a burnup analysis model in Simulink® considering only the 10 most probable low Z and 10 most probable high Z elements of the fission yield peaks plus 149Sm. Results show that the predicted operational lifetimes using the simplified method are within -6.6 to 12.8% of those calculated using the widely used Monteburns 2.0 and MCNPX 2.6bc1 codes.

  10. A Novel Method for Determining the Phase of T-Wave Alternans: Diagnostic and Therapeutic Implications

    PubMed Central

    Sayadi, Omid; Merchant, Faisal M.; Puppala, Dheeraj; Mela, Theofanie; Singh, Jagmeet P.; Heist, E. Kevin; Owen, Chris; Armoundas, Antonis A.

    2013-01-01

    Background T-wave alternans (TWA) has been implicated in the pathogenesis of ventricular arrhythmias and sudden cardiac death (SCD). However, in order to effectively estimate and suppress TWA, the phase of TWA must be accurately determined. Methods and Results We developed a method that computes the beat-by-beat integral of the T-wave morphology, over time points within the T-wave with positive alternans. Then, we estimated the signed derivative of the T-wave integral sequence which allows the classification of each beat to a binary phase index. In animal studies, we found that this method was able to accurately identify the T-wave phase in artificially induced alternans (p<0.0001). The coherence of the phase increased consistently after acute ischemia induction in all body-surface and intracardiac leads (p<0.0001). Also, we developed a phase resetting detection algorithm that enhances the diagnostic utility of TWA. We further established an algorithm that employs the phase of TWA in order to deliver appropriate polarity pacing pulses (all interventions compared to baseline, p<0.0001 for alternans voltage; p<0.0001 for Kscore), to suppress TWA. Finally, we demonstrated that using the phase of TWA we can suppress spontaneous TWA during acute ischemia; 77.6% for alternans voltage (p<0.0001) and 92.5% for Kscore (p<0.0001). Conclusions We developed a method to quantify the temporal variability of the TWA phase. This method is expected to enhance the utility of TWA in predicting ventricular arrhythmias and SCD and raises the possibility of using upstream therapies to abort a ventricular tachyarrhythmia prior to its onset. PMID:23884196

  11. Simplified Symptom Pattern Method for verbal autopsy analysis: multisite validation study using clinical diagnostic gold standards

    PubMed Central

    2011-01-01

    Background Verbal autopsy can be a useful tool for generating cause of death data in data-sparse regions around the world. The Symptom Pattern (SP) Method is one promising approach to analyzing verbal autopsy data, but it has not been tested rigorously with gold standard diagnostic criteria. We propose a simplified version of SP and evaluate its performance using verbal autopsy data with accompanying true cause of death. Methods We investigated specific parameters in SP's Bayesian framework that allow for its optimal performance in both assigning individual cause of death and in determining cause-specific mortality fractions. We evaluated these outcomes of the method separately for adult, child, and neonatal verbal autopsies in 500 different population constructs of verbal autopsy data to analyze its ability in various settings. Results We determined that a modified, simpler version of Symptom Pattern (termed Simplified Symptom Pattern, or SSP) performs better than the previously-developed approach. Across 500 samples of verbal autopsy testing data, SSP achieves a median cause-specific mortality fraction accuracy of 0.710 for adults, 0.739 for children, and 0.751 for neonates. In individual cause of death assignment in the same testing environment, SSP achieves 45.8% chance-corrected concordance for adults, 51.5% for children, and 32.5% for neonates. Conclusions The Simplified Symptom Pattern Method for verbal autopsy can yield reliable and reasonably accurate results for both individual cause of death assignment and for determining cause-specific mortality fractions. The method demonstrates that verbal autopsies coupled with SSP can be a useful tool for analyzing mortality patterns and determining individual cause of death from verbal autopsy data. PMID:21816099

  12. Methods of performing downhole operations using orbital vibrator energy sources

    DOEpatents

    Cole, Jack H.; Weinberg, David M.; Wilson, Dennis R.

    2004-02-17

    Methods of performing down hole operations in a wellbore. A vibrational source is positioned within a tubular member such that an annulus is formed between the vibrational source and an interior surface of the tubular member. A fluid medium, such as high bulk modulus drilling mud, is disposed within the annulus. The vibrational source forms a fluid coupling with the tubular member through the fluid medium to transfer vibrational energy to the tubular member. The vibrational energy may be used, for example, to free a stuck tubular, consolidate a cement slurry and/or detect voids within a cement slurry prior to the curing thereof.

  13. Method of and apparatus for operating industrial furnace systems

    SciTech Connect

    Rohrbach, H.

    1980-04-15

    A method and apparatus for operating an industrial furnace system for treating materials are disclosed, characterized in that the heat which is applied to the material to be treated is partially derived from the combustion of a mixture of waste fuel and water such as sewage slurry. Waste heat generated at the outer surface of the furnace and waste heat generated from the cooling of the treated material is further applied to the slurry to partially dry the waste fuel prior to and during the combustion thereof.

  14. Method of operating a two-stage coal gasifier

    DOEpatents

    Tanca, Michael C.

    1982-01-01

    A method of operating an entrained flow coal gasifier (10) via a two-stage gasification process. A portion of the coal (18) to be gasified is combusted in a combustion zone (30) with near stoichiometric air to generate combustion products. The combustion products are conveyed from the combustion zone into a reduction zone (32) wherein additional coal is injected into the combustion products to react with the combustion products to form a combustible gas. The additional coal is injected into the reduction zone as a mixture (60) consisting of coal and steam, preferably with a coal-to-steam weight ratio of approximately ten to one.

  15. Rapid diagnostic methods for influenza virus in clinical specimens - A comparative study

    NASA Technical Reports Server (NTRS)

    Evans, A. S.; Olson, B.

    1982-01-01

    A comparison of five rapid viral diagnostic techniques for identifying influenza virus in nasopharyngeal aspirates has been made on patients with influenza-like illnesses. Initial results with immune electron microscopy were positive in only one of 11 specimens from which virus was isolated and further work abandoned. Four other rapid tests were carried out on 39 specimens from which influenza virus had been isolated in tissue culture in 28. Of these 28 specimens yielding virus, 24 (85.7 percent) were positive by an indirect fluorescent antibody test (IFAT) on nasopharyngeal cells, 18 (64.3 percent) by enzyme-linked immunosorbent assay (ELISA), 19 (67.8 percent) by enzyme-linked fluorescent assay (ELFA), and 26 (92.8 percent) by a rapid tissue culture amplification method (TCA) in a continuous Rhesus monkey kidney line (LLC-MK2) with identification of virus by fluorescent antibody. In terms of sensitivity, simplicity, and rapidity, a combination of the IFAT and TCA methods seems to be very useful.

  16. Accuracy of diagnostic methods and surveillance sensitivity for human enterovirus, South Korea, 1999-2011.

    PubMed

    Hyeon, Ji-Yeon; Hwang, Seoyeon; Kim, Hyejin; Song, Jaehyoung; Ahn, Jeongbae; Kang, Byunghak; Kim, Kisoon; Choi, Wooyoung; Chung, Jae Keun; Kim, Cheon-Hyun; Cho, Kyungsoon; Jee, Youngmee; Kim, Jonghyun; Kim, Kisang; Kim, Sun-Hee; Kim, Min-Ji; Cheon, Doo-Sung

    2013-08-01

    The epidemiology of enteroviral infection in South Korea during 1999-2011 chronicles nationwide outbreaks and changing detection and subtyping methods used over the 13-year period. Of 14,657 patients whose samples were tested, 4,762 (32.5%) samples were positive for human enterovirus (human EV); as diagnostic methods improved, the rate of positive results increased. A seasonal trend of outbreaks was documented. Genotypes enterovirus 71, echovirus 30, coxsackievirus B5, enterovirus 6, and coxsackievirus B2 were the most common genotypes identified. Accurate test results correlated clinical syndromes to enterovirus genotypes: aseptic meningitis to echovirus 30, enterovirus 6, and coxsackievirus B5; hand, foot and mouth disease to coxsackievirus A16; and hand, foot and mouth disease with neurologic complications to enterovirus 71. There are currently no treatments specific to human EV infections; surveillance of enterovirus infections such as this study provides may assist with evaluating the need to research and develop treatments for infections caused by virulent human EV genotypes.

  17. Perspective ground-based method for diagnostics of the lower ionosphere and the neutral atmosphere

    NASA Astrophysics Data System (ADS)

    Bakhmetieva, N. V.; Grigoriev, G. I.; Tolmacheva, A. V.

    We present a new perspective ground-based method for diagnostics of the ionosphere and atmosphere parameters. The method uses one of the numerous physical phenomena observed in the ionosphere illuminated by high-power radio waves. It is a generation of the artificial periodic irregularities (APIs) in the ionospheric plasma. The APIs were found while studying the effects of ionospheric high-power HF modification. It was established that the APIs are formed by a standing wave that occurs due to interference between the upwardly radiated radio wave and its reflection off the ionosphere. The API studies are based upon observation of the Bragg backscatter of the pulsed probe radio wave from the artificial periodic structure. Bragg backscatter occurs if the spatial period of the irregularities is equal to half a wavelength of the probe signal. The API techniques makes it possible to obtain the following information: the profiles of electron density from the lower D-region up to the maximum of the F-layer; the irregular structure of the ionosphere including split of the regular E-layer, the sporadic layers; the vertical velocities in the D- and E-regions of the ionosphere; the turbulent velocities, turbulent diffusion coefficients and the turbopause altitude; the neutral temperatures and densities at the E-region altitudes; the parameters of the internal gravity waves and their spectral characteristics; the relative concentration of negative oxygen ions in the D-region. Some new results obtained by the API technique are discussed .

  18. Diagnostic electrocardiography in epidemiological studies of Chagas' disease: multicenter evaluation of a standardized method.

    PubMed

    Lázzari, J O; Pereira, M; Antunes, C M; Guimarães, A; Moncayo, A; Chávez Domínguez, R; Hernández Pieretti, O; Macedo, V; Rassi, A; Maguire, J; Romero, A

    1998-11-01

    An electrocardiographic recording method with an associated reading guide, designed for epidemiological studies on Chagas' disease, was tested to assess its diagnostic reproducibility. Six cardiologists from five countries each read 100 electrocardiographic (ECG) tracings, including 30 from chronic chagasic patients, then reread them after an interval of 6 months. The readings were blind, with the tracings numbered randomly for the first reading and renumbered randomly for the second reading. The physicians, all experienced in interpreting ECGs from chagasic patients, followed printed instructions for reading the tracings. Reproducibility of the readings was evaluated using the kappa (kappa) index for concordance. The results showed a high degree of interobserver concordance with respect to the diagnosis of normal vs. abnormal tracings (kappa = 0.66; SE 0.02). While the interpretations of some categories of ECG abnormalities were highly reproducible, others, especially those having a low prevalence, showed lower levels of concordance. Intraobserver concordance was uniformly higher than interobserver concordance. The findings of this study justify the use by specialists of the recording of readings method proposed for epidemiological studies on Chagas' disease, but warrant caution in the interpretation of some categories of electrocardiographic alterations.

  19. Modified method to enhanced recovery of Toxocara cati larvae for the purposes of diagnostic and therapeutic.

    PubMed

    Zibaei, Mohammad; Uga, Shoji

    2016-10-01

    Human toxocariasis, extraintestinal-migration of Toxocara species, is a worldwide helminthic zoonosis in many places of the undeveloped countries. Toxocara cati is one of the common helminths in cats and it is a potentially preventable disease. Its diagnosis and treatment depend on the demonstration of specific excretory-secretory Toxocara antibodies from Toxocara larvae by immunological assays. This study provides a simple manual technique which can be performed in any laboratory for recovering a large number of Toxocara cati larvae from the thick-shelled eggs. The devices that are required contain a manual homogenizer and a filter membrane of 40 μm mesh; the rest of materials and solutions is standard laboratory ware. In the modified method the larval yields were 2.7 times higher (3000 larval/ml) and the time spent in performing the modified method was shorter (75 min). Further benefits over already techniques are the easy and repeatable, inexpensive and convenient materials, simplicity to perform and require less time for recovery of Toxocara cati larvae for subsequent cultivation and harvest of the larval excretory-secretory antigens for diagnostic or treatment purposes. PMID:27502936

  20. Gene dosage methods as diagnostic tools for the identification of chromosome abnormalities.

    PubMed

    Gouas, L; Goumy, C; Véronèse, L; Tchirkov, A; Vago, P

    2008-09-01

    Cytogenetics is the part of genetics that deals with chromosomes, particularly with numerical and structural chromosome abnormalities, and their implications in congenital or acquired genetic disorders. Standard karyotyping, successfully used for the last 50 years in investigating the chromosome etiology in patients with infertility, fetal abnormalities and congenital disorders, is constrained by the limits of microscopic resolution and is not suited for the detection of subtle chromosome abnormalities. The ability to detect submicroscopic chromosomal rearrangements that lead to copy-number changes has escalated progressively in recent years with the advent of molecular cytogenetic techniques. Here, we review various gene dosage methods such as FISH, PCR-based approaches (MLPA, QF-PCR, QMPSF and real time PCR), CGH and array-CGH, that can be used for the identification and delineation of copy-number changes for diagnostic purposes. Besides comparing their relative strength and weakness, we will discuss the impact that these detection methods have on our understanding of copy number variations in the human genome and their implications in genetic counseling. PMID:18513889

  1. [The use of multivariate mathematical methods in medical diagnostic systems--a model for the evaluation of cytological smears].

    PubMed

    Molnár, B; Szentirmay, Z; Bodó, M; Sugár, J; Fehér, J

    1992-10-18

    The methods of the multivariate mathematics have been applied in several studies to increase the diagnostic reliability of medical decision support system. In the recent years some new algorithms for decision support (fuzzy logic) and for pattern recognition (neural nets), both specified by nonlinearity, were developed. This paper provides results for the application of this methods in the area of quantitative cytology and the comparison with the traditional classifiers. 21 normal, 15 dysplastic, 23 malignant, Feulgen stained gastric imprint smears were analysed on a Leitz Miamed DNA equipment. The determination of mean DNA content, the 2c deviation index (2cDI), 5c Exceeding rate (RcER), G1,S,G2 phase fraction ratios, cell nucleus area, form factor was performed. The discriminant analysis classified correctly the 95.6% of malignant cases, 86.7% of dysplasias, and 80.7% normal cases. Our diagnostic system using fuzzy logic made the diagnostic borders fine tuneable, and reliable. The back propagation neural net could classify all three diagnostic groups above 95% correctly. The application of nonlinear computational methods made the diagnostic system more reliable. The application of these algorithms are encouraged.

  2. Underwater application of nasal decongestants: method for special operations.

    PubMed

    Mutzbauer, T S; Mueller, P H; Sigg, O; Tetzlaff, K; Neubauer, B

    2000-11-01

    A simple method of emergency underwater application of a nasal decongestant in divers to prevent diving-related accidents or even fatalities attributable to sequelae of middle-ear and sinus barotrauma of ascent was evaluated. Eleven military divers had to inject 1 mL of 0.02% methylene blue into a central venous catheter after having inserted the tip between their upper lip and the mask at 1 m depth in a pool. After injection, the head had to be reclined. Blue liquid flowing from a diver's nostril and a "bitter" taste sensation reported immediately after surfacing indicated successful application. All divers were observed to have had blue liquid flowing from the nostril of application, and one diver could not describe the taste. This method of underwater application of nasal decongestants may be useful for emergency prevention in divers, especially during covert operations. Underwater availability of the system in a special kit carried by divers would be required.

  3. Method for operating a combustor in a fuel cell system

    DOEpatents

    Chalfant, Robert W.; Clingerman, Bruce J.

    2002-01-01

    A method of operating a combustor to heat a fuel processor in a fuel cell system, in which the fuel processor generates a hydrogen-rich stream a portion of which is consumed in a fuel cell stack and a portion of which is discharged from the fuel cell stack and supplied to the combustor, and wherein first and second streams are supplied to the combustor, the first stream being a hydrocarbon fuel stream and the second stream consisting of said hydrogen-rich stream, the method comprising the steps of monitoring the temperature of the fuel processor; regulating the quantity of the first stream to the combustor according to the temperature of the fuel processor; and comparing said quantity of said first stream to a predetermined value or range of predetermined values.

  4. Absolute calibration method for laser megajoule neutron yield measurement by activation diagnostics

    NASA Astrophysics Data System (ADS)

    Landoas, Olivier; Yu Glebov, Vladimir; Rossé, Bertrand; Briat, Michelle; Disdier, Laurent; Sangster, Thomas C.; Duffy, Tim; Marmouget, Jean Gabriel; Varignon, Cyril; Ledoux, Xavier; Caillaud, Tony; Thfoin, Isabelle; Bourgade, Jean-Luc

    2011-07-01

    The laser megajoule (LMJ) and the National Ignition Facility (NIF) plan to demonstrate thermonuclear ignition using inertial confinement fusion (ICF). The neutron yield is one of the most important parameters to characterize ICF experiment performance. For decades, the activation diagnostic was chosen as a reference at ICF facilities and is now planned to be the first nuclear diagnostic on LMJ, measuring both 2.45 MeV and 14.1 MeV neutron yields. Challenges for the activation diagnostic development are absolute calibration, accuracy, range requirement, and harsh environment. At this time, copper and zirconium material are identified for 14.1 MeV neutron yield measurement and indium material for 2.45 MeV neutrons. A series of calibrations were performed at Commissariat à l'Energie Atomique (CEA) on a Van de Graff facility to determine activation diagnostics efficiencies and to compare them with results from calculations. The CEA copper activation diagnostic was tested on the OMEGA facility during DT implosion. Experiments showed that CEA and Laboratory for Laser Energetics (LLE) diagnostics agree to better than 1% on the neutron yield measurement, with an independent calibration for each system. Also, experimental sensitivities are in good agreement with simulations and allow us to scale activation diagnostics for the LMJ measurement range.

  5. An in vitro comparison of different diagnostic methods in detection of residual dentinal caries.

    PubMed

    Unlu, Nimet; Ermis, Rabia Banu; Sener, Sevgi; Kucukyilmaz, Ebru; Cetin, Ali Riza

    2010-01-01

    The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF) device, electronic caries monitor(ECM), and caries detector dye(CDD) by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 mum in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lightmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement) for CDD, 0.86 (excellent agreement) for ECM, and 0.50 (good agreement) for LF. The average interobserver accuracy values were 0.92 (excellent agreement), (0.36 marginal agreement) and 0.48 (good agreement), for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection.

  6. An In Vitro Comparison of Different Diagnostic Methods in Detection of Residual Dentinal Caries

    PubMed Central

    Unlu, Nimet; Ermis, Rabia Banu; Sener, Sevgi; Kucukyilmaz, Ebru; Cetin, Ali Riza

    2010-01-01

    The aim of this study was to investigate the efficiency of different diagnostic methods in detection of residual dentinal caries in excavated cavities. Fifty extracted molar with deep dentinal carious lesions were excavated using a slow-speed handpiece. All cavities were assessed by laser fluorescence(LF) device, electronic caries monitor(ECM), and caries detector dye(CDD) by three independent observers blindly. The measurements were repeated after two weeks. Specimens containing dentin slices 150 μm in thickness were prepared for histological analyses. The existence and absence of carious dentin was determined using a lightmicroscope. The average intraobserver accuracy was 1.00 (perfect agreement) for CDD, 0.86 (excellent agreement) for ECM, and 0.50 (good agreement) for LF. The average interobserver accuracy values were 0.92 (excellent agreement), (0.36 marginal agreement) and 0.48 (good agreement), for CDD, ECM, and LF, respectively. The average specificity was 0.60 for CDD, 73% for ECM, and 0.50 for LF. The average sensitivity was 0.55 for CDD, 0.85 for LF, and 0.47 for ECM. The average accuracy values were 0.53, 0.51, and 0.81 for CDD, ECM, and LF, respectively. LF had the greatest sensitivity and accuracy values of any of the methods tested. As a conclusion, LF device is appeared to most reliable method in detection of remain caries in cavity. However, because of its technical sensitivity it may susceptible to variations in measurements. To pay attention to the rule of usage and repeated measurements can minimize such variations in clinical practice. It was concluded that LF is an improvement on the currently available aids for residual caries detection. PMID:20613961

  7. The conversion of CESR to operate as the Test Accelerator, CesrTA. Part 3: Electron cloud diagnostics

    DOE PAGES

    Billing, M. G.; Conway, J. V.; Crittenden, J. A.; Greenwald, S.; Li, Y.; Meller, R. E.; Strohman, C. R.; Sikora, J. P.; Calvey, J. R.; Palmer, M. A.

    2016-04-28

    Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper is the third in a series of four describing the conversion of CESR to themore » test accelerator, CESRTA. The first two papers discuss the overall plan for the conversion of the storage ring to an instrument capable of studying advanced accelerator physics issues [1] and the details of the vacuum system upgrades [2]. This paper focuses on the necessary development of new instrumentation, situated in four dedicated experimental regions, capable of studying such phenomena as electron clouds (ECs) and methods to mitigate EC effects. The fourth paper in this series describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of EC behavior within wigglers. Lastly, while the initial studies of CESRTA focused on questions related to the International Linear Collider damping ring design, CESRTA is a very versatile storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.« less

  8. The conversion of CESR to operate as the Test Accelerator, CesrTA. Part 3: electron cloud diagnostics

    NASA Astrophysics Data System (ADS)

    Billing, M. G.; Conway, J. V.; Crittenden, J. A.; Greenwald, S.; Li, Y.; Meller, R. E.; Strohman, C. R.; Sikora, J. P.; Calvey, J. R.; Palmer, M. A.

    2016-04-01

    Cornell's electron/positron storage ring (CESR) was modified over a series of accelerator shutdowns beginning in May 2008, which substantially improves its capability for research and development for particle accelerators. CESR's energy span from 1.8 to 5.6 GeV with both electrons and positrons makes it ideal for the study of a wide spectrum of accelerator physics issues and instrumentation related to present light sources and future lepton damping rings. Additionally a number of these are also relevant for the beam physics of proton accelerators. This paper is the third in a series of four describing the conversion of CESR to the test accelerator, CESRTA. The first two papers discuss the overall plan for the conversion of the storage ring to an instrument capable of studying advanced accelerator physics issues [1] and the details of the vacuum system upgrades [2]. This paper focusses on the necessary development of new instrumentation, situated in four dedicated experimental regions, capable of studying such phenomena as electron clouds (ECs) and methods to mitigate EC effects. The fourth paper in this series describes the vacuum system modifications of the superconducting wigglers to accommodate the diagnostic instrumentation for the study of EC behavior within wigglers. While the initial studies of CESRTA focussed on questions related to the International Linear Collider damping ring design, CESRTA is a very versatile storage ring, capable of studying a wide range of accelerator physics and instrumentation questions.

  9. Advanced Imaging and Diagnostic Methods in the Assessment of Suspected Ischemic Heart Disease in Women.

    PubMed

    Joly, Joanna M; Bittner, Vera

    2016-09-01

    Although differences diminish with age, outcomes are overall worse for women compared to men who present with suspected acute coronary syndrome. The reasons for this discrepancy are multifactorial, including sex-related differences in atherosclerosis biology and fluid dynamics, as well as a premature conclusion by providers that chest pain must be noncardiac in the absence of obstructive coronary artery disease. In this review of existing literature, we explore the diverse differential diagnosis in this unique set of patients. Especially in women with persistent symptoms, absence of occlusive disease should prompt consideration for subangiographic plaque disruption, epicardial or microvascular endothelial dysfunction, transient neurohormonal imbalance predisposing to Takotsubo cardiomyopathy or spontaneous coronary artery dissection, underlying systemic inflammatory conditions, thromboembolic disease, myocarditis, and sequelae of congenital heart disease. As always, a thorough history and attentive physical exam will help guide further work-up, which in many cases may warrant noninvasive imaging, such as contrast-enhanced echocardiography, cardiac magnetic resonance imaging, or positron emission tomography, with their respective means of measuring myocardial perfusion and myocardial tissue pathology. Lastly, intracoronary imaging such as intravascular ultrasound and optical coherence tomography and invasive diagnostic methods such as coronary reactivity testing continue to add to our understanding that what appear to be atypical presentations of ischemic heart disease in women may in fact be typical presentations of pathologic cousin entities that remain incompletely defined. PMID:27443380

  10. Diffusion Weighted Imaging for Differentiating Benign from Malignant Orbital Tumors: Diagnostic Performance of the Apparent Diffusion Coefficient Based on Region of Interest Selection Method

    PubMed Central

    Xu, Xiao-Quan; Hu, Hao; Su, Guo-Yi; Liu, Hu; Shi, Hai-Bin

    2016-01-01

    Objective To evaluate the differences in the apparent diffusion coefficient (ADC) measurements based on three different region of interest (ROI) selection methods, and compare their diagnostic performance in differentiating benign from malignant orbital tumors. Materials and Methods Diffusion-weighted imaging data of sixty-four patients with orbital tumors (33 benign and 31 malignant) were retrospectively analyzed. Two readers independently measured the ADC values using three different ROIs selection methods including whole-tumor (WT), single-slice (SS), and reader-defined small sample (RDSS). The differences of ADC values (ADC-ROIWT, ADC-ROISS, and ADC-ROIRDSS) between benign and malignant group were compared using unpaired t test. Receiver operating characteristic curve was used to determine and compare their diagnostic ability. The ADC measurement time was compared using ANOVA analysis and the measurement reproducibility was assessed using Bland-Altman method and intra-class correlation coefficient (ICC). Results Malignant group showed significantly lower ADC-ROIWT, ADC-ROISS, and ADC-ROIRDSS than benign group (all p < 0.05). The areas under the curve showed no significant difference when using ADC-ROIWT, ADC-ROISS, and ADC-ROIRDSS as differentiating index, respectively (all p > 0.05). The ROISS and ROIRDSS required comparable measurement time (p > 0.05), while significantly shorter than ROIWT (p < 0.05). The ROISS showed the best reproducibility (mean difference ± limits of agreement between two readers were 0.022 [-0.080–0.123] × 10-3 mm2/s; ICC, 0.997) among three ROI methods. Conclusion Apparent diffusion coefficient values based on the three different ROI selection methods can help to differentiate benign from malignant orbital tumors. The results of measurement time, reproducibility and diagnostic ability suggest that the ROISS method are potentially useful for clinical practice. PMID:27587953

  11. Development of Monitoring and Diagnostic Methods for Robots Used In Remediation of Waste Sites - Final Report

    SciTech Connect

    Martin, M.

    2000-04-01

    This project is the first evaluation of model-based diagnostics to hydraulic robot systems. A greater understanding of fault detection for hydraulic robots has been gained, and a new theoretical fault detection model developed and evaluated.

  12. Development of a benchtop baking method for chemically leavened crackers. I. Identification of a diagnostic formula and procedure

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A benchtop baking method has been developed to predict the contribution of gluten functionality to overall flour performance for chemically leavened crackers. In order to identify a diagnostic cracker formula, the effects of leavening system (sodium bicarbonate, monocalcium phosphate, and ammonium b...

  13. Development of practical diagnostic methods for monitoring rice bacterial panicle blight disease and evaluation of rice germplasm for resistance

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A study was initiated to understand Burkholderia glumae, the major causal agent for bacterial panicle blight disease of rice; to develop practical diagnostic methods for monitoring the disease; and to evaluate rice germplasm for resistance. Burkholderia glumae was frequently isolated from infected p...

  14. Development of practical diagnostic methods for monitoring rice bacterial panicle blight disease and evaluation of rice germplasm for resistance

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A study was initiated to understand Burkholderia glumae (major causal agent for bacterial panicle blight disease of rice) to develop practical diagnostic methods for monitoring the disease; and to evaluate rice germplasm for resistance. B. glumae was frequently isolated from symptomatic panicles on...

  15. Dental flossing as a diagnostic method for proximal gingivitis: a validation study.

    PubMed

    Grellmann, Alessandra Pascotini; Kantorski, Karla Zanini; Ardenghi, Thiago Machado; Moreira, Carlos Heitor Cunha; Danesi, Cristiane Cademartori; Zanatta, Fabricio Batistin

    2016-05-20

    This study evaluated the clinical diagnosis of proximal gingivitis by comparing two methods: dental flossing and the gingival bleeding index (GBI). One hundred subjects (aged at least 18 years, with 15% of positive proximal sites for GBI, without proximal attachment loss) were randomized into five evaluation protocols. Each protocol consisted of two assessments with a 10-minute interval between them: first GBI/second floss, first floss/second GBI, first GBI/second GBI, first tooth floss/second floss, and first gum floss-second floss. The dental floss was slid against the tooth surface (TF) and the gingival tissue (GF). The evaluated proximal sites should present teeth with established point of contact and probing depth ≤ 3mm. One trained and calibrated examiner performed all the assessments. The mean percentages of agreement and disagreement were calculated for the sites with gingival bleeding in both evaluation methods (GBI and flossing). The primary outcome was the percentage of disagreement between the assessments in the different protocols. The data were analyzed by one-way ANOVA, McNemar, chi-square and Tukey's post hoc tests, with a 5% significance level. When gingivitis was absent in the first assessment (negative GBI), bleeding was detected in the second assessment by TF and GF in 41.7% (p < 0.001) and 50.7% (p < 0.001) of the sites, respectively. In the absence of gingivitis in the second assessment (negative GBI), TF and GF detected bleeding in the first assessment in 38.9% (p = 0.004) and 58.3% (p < 0.001) of the sites, respectively. TF and GF appears to be a better diagnostic indicator of proximal gingivitis than GBI. PMID:27223134

  16. Dental flossing as a diagnostic method for proximal gingivitis: a validation study.

    PubMed

    Grellmann, Alessandra Pascotini; Kantorski, Karla Zanini; Ardenghi, Thiago Machado; Moreira, Carlos Heitor Cunha; Danesi, Cristiane Cademartori; Zanatta, Fabricio Batistin

    2016-05-20

    This study evaluated the clinical diagnosis of proximal gingivitis by comparing two methods: dental flossing and the gingival bleeding index (GBI). One hundred subjects (aged at least 18 years, with 15% of positive proximal sites for GBI, without proximal attachment loss) were randomized into five evaluation protocols. Each protocol consisted of two assessments with a 10-minute interval between them: first GBI/second floss, first floss/second GBI, first GBI/second GBI, first tooth floss/second floss, and first gum floss-second floss. The dental floss was slid against the tooth surface (TF) and the gingival tissue (GF). The evaluated proximal sites should present teeth with established point of contact and probing depth ≤ 3mm. One trained and calibrated examiner performed all the assessments. The mean percentages of agreement and disagreement were calculated for the sites with gingival bleeding in both evaluation methods (GBI and flossing). The primary outcome was the percentage of disagreement between the assessments in the different protocols. The data were analyzed by one-way ANOVA, McNemar, chi-square and Tukey's post hoc tests, with a 5% significance level. When gingivitis was absent in the first assessment (negative GBI), bleeding was detected in the second assessment by TF and GF in 41.7% (p < 0.001) and 50.7% (p < 0.001) of the sites, respectively. In the absence of gingivitis in the second assessment (negative GBI), TF and GF detected bleeding in the first assessment in 38.9% (p = 0.004) and 58.3% (p < 0.001) of the sites, respectively. TF and GF appears to be a better diagnostic indicator of proximal gingivitis than GBI.

  17. Method for starting operation of a resistance melter

    DOEpatents

    Chapman, Christopher Charles

    1977-01-01

    A method for starting the operation of a resistance furnace, where heating occurs by passing a current through the charge between two furnace electrodes and the charge is a material which is essentially electrically nonconductive when in a solid physical state but which becomes more electrically conductive when in a molten physical state, by connecting electrical resistance heating wire between the furnace electrodes, placing the wire in contact with the charge material between the electrodes and passing a current through the wire to heat the wire to a temperature sufficient to melt the material between the furnace electrodes so that as the material melts, current begins to pass between the electrodes through the melted material, further heating and melting more material until all current between the electrodes passes through the charge material without the aid or presence of the resistance element.

  18. Induction heating apparatus and methods of operation thereof

    SciTech Connect

    Richardson, John G.

    2006-08-01

    Methods of operation of an induction melter include providing material within a cooled crucible proximate an inductor. A desired electromagnetic flux skin depth for heating the material within the crucible may be selected, and a frequency of an alternating current for energizing the inductor and for producing the desired skin depth may be selected. The alternating current frequency may be adjusted after energizing the inductor to maintain the desired electromagnetic flux skin depth. The desired skin depth may be substantially maintained as the temperature of the material varies. An induction heating apparatus includes a sensor configured to detect changes in at least one physical characteristic of a material to be heated in a crucible, and a controller configured for selectively varying a frequency of an alternating current for energizing an inductor at least partially in response to changes in the physical characteristic to be detected by the sensor.

  19. An Innovative Operative Method for Correction of Tracheal Stenosis.

    PubMed

    Shah, Dakshesh R; Mungutwar, Varsha

    2016-09-01

    This is a case of failed attempt of hanging, resulted into cervical injury & injury to the trachea. Patient was put on the ventilator for respiratory support for long period. Poor recovery of the patient resulted into prolong tracheostomy tube. Combine effect of all resulted into suprastomal tracheal stenosis. Due to complexity of the problem a novel method was customized to correct the tracheal stenosis. Strap muscle (Sternohyoid & Sternothyroid) was raised as a flap; free cartilage was sandwiched in between and sutured to the created tracheal defect. Bovine collagen was placed over a stent and placed in the tracheal lumen. Good result was achieved post operatively in the form of adequate lumen, rigid anterior wall during respiration, good mucosal lining without fibrosis and normal speech. PMID:27508127

  20. Method and system for operating an electric motor

    DOEpatents

    Gallegos-Lopez, Gabriel; Hiti, Silva; Perisic, Milun

    2013-01-22

    Methods and systems for operating an electric motor having a plurality of windings with an inverter having a plurality of switches coupled to a voltage source are provided. A first plurality of switching vectors is applied to the plurality of switches. The first plurality of switching vectors includes a first ratio of first magnitude switching vectors to second magnitude switching vectors. A direct current (DC) current associated with the voltage source is monitored during the applying of the first plurality of switching vectors to the plurality of switches. A second ratio of the first magnitude switching vectors to the second magnitude switching vectors is selected based on the monitoring of the DC current associated with the voltage source. A second plurality of switching vectors is applied to the plurality of switches. The second plurality of switching vectors includes the second ratio of the first magnitude switching vectors to the second magnitude switching vectors.

  1. Target detection in diagnostic ultrasound: Evaluation of a method based on the CLEAN algorithm.

    PubMed

    Masoom, Hassan; Adve, Raviraj S; Cobbold, Richard S C

    2013-02-01

    A technique is proposed for the detection of abnormalities (targets) in ultrasound images using little or no a priori information and requiring little operator intervention. The scheme is a combination of the CLEAN algorithm, originally proposed for radio astronomy, and constant false alarm rate (CFAR) processing, as developed for use in radar systems. The CLEAN algorithm identifies areas in the ultrasound image that stand out above a threshold in relation to the background; CFAR techniques allow for an adaptive, semi-automated, selection of the threshold. Neither appears to have been previously used for target detection in ultrasound images and never together in any context. As a first step towards assessing the potential of this method we used a widely used method of simulating B-mode images (Field II). We assumed the use of a 256 element linear array operating at 3.0MHz into a water-like medium containing a density of point scatterers sufficient to simulate a background of fully developed speckle. Spherical targets with diameters ranging from 0.25 to 6.0mm and contrasts ranging from 0 to 12dB relative to the background were used as test objects. Using a contrast-detail analysis, the probability of detection curves indicate these targets can be consistently detected within a speckle background. Our results indicate that the method has considerable promise for the semi-automated detection of abnormalities with diameters greater than a few millimeters, depending on the contrast.

  2. Evaluation of different diagnostic methods of American Cutaneous Leishmaniasis in the Brazilian Amazon.

    PubMed

    Espir, Thais Tibery; Guerreiro, Thayanne Sá; Naiff, Maricleide de Farias; Figueira, Luanda de Paula; Soares, Fabiane Veloso; da Silva, Susi Simas; Franco, Antonia Maria Ramos

    2016-08-01

    Epidemiological studies have been conducted to better understand the dynamics of American Cutaneous Leishmaniasis (ACL) in the Amazon region where distinct species of Leishmania circulate. In endemic areas, the optimal diagnosis must be made in the earlier clinical presentation to avoid the complications of chronic disease. The scarcity of financial support, laboratory infrastructure and trained persons are the major obstacles in this reality. This paper describes the result of performing different diagnostic methods for ACL in Amazonas State between the years 2010 and 2011. The tests used were the intradermal skin test (Montenegro's skin test), ELISA (Enzyme-Linked Immunosorbent Assay), direct examination, culture isolation and identification of Leishmania species. A total of 38 suspected human cases of ACL were diagnosed by different methods, of which 71.0% (n = 27) were positive by direct examination, 75.6% (n = 28) had positivity in the culture isolates and, of these, 54.0% (n = 19) had infection with Leishmania (Viannia) guyanensis. The positivity of the intradermal skin test with the leishmanin solution was observed in 77.0% of cases analyzed and the serology with detection of IgG and IgM showed the presence of antibodies in 100% of exams realized results, showing variation in the titles of antibodies. The success of Leishmaniasis treatment depends on an effective and early diagnosis. Parasitological diagnosis is highly specific, but sensitivity is subject to variation because the tissue distribution of parasites generally is not homogeneous and depends on the specie of parasite. Moreover, parasitological tests require invasive procedures and depend on restrictive conditions for the collection of biological sample, which limit their use in large-scale for epidemiological studies. ELISA has been the most widely used serological method for the diagnosis of Visceral Leishmaniasis (VL) as it is easy to perform and has a low cost. However, flaws in

  3. Stochastic operator-splitting method for reaction-diffusion systems

    NASA Astrophysics Data System (ADS)

    Choi, TaiJung; Maurya, Mano Ram; Tartakovsky, Daniel M.; Subramaniam, Shankar

    2012-11-01

    Many biochemical processes at the sub-cellular level involve a small number of molecules. The local numbers of these molecules vary in space and time, and exhibit random fluctuations that can only be captured with stochastic simulations. We present a novel stochastic operator-splitting algorithm to model such reaction-diffusion phenomena. The reaction and diffusion steps employ stochastic simulation algorithms and Brownian dynamics, respectively. Through theoretical analysis, we have developed an algorithm to identify if the system is reaction-controlled, diffusion-controlled or is in an intermediate regime. The time-step size is chosen accordingly at each step of the simulation. We have used three examples to demonstrate the accuracy and robustness of the proposed algorithm. The first example deals with diffusion of two chemical species undergoing an irreversible bimolecular reaction. It is used to validate our algorithm by comparing its results with the solution obtained from a corresponding deterministic partial differential equation at low and high number of molecules. In this example, we also compare the results from our method to those obtained using a Gillespie multi-particle (GMP) method. The second example, which models simplified RNA synthesis, is used to study the performance of our algorithm in reaction- and diffusion-controlled regimes and to investigate the effects of local inhomogeneity. The third example models reaction-diffusion of CheY molecules through the cytoplasm of Escherichia coli during chemotaxis. It is used to compare the algorithm's performance against the GMP method. Our analysis demonstrates that the proposed algorithm enables accurate simulation of the kinetics of complex and spatially heterogeneous systems. It is also computationally more efficient than commonly used alternatives, such as the GMP method.

  4. Is there any superiority among diagnostic methods in organizing pneumonia in terms of clinical features of the patients?

    PubMed Central

    Kavakli, Kuthan; Ocal, Nesrin; Dogan, Deniz; Cicek, Ali Fuat; Isik, Hakan; Gurkok, Sedat

    2016-01-01

    Background Organizing pneumonia (OP) can be idiopathic or secondary to some clinical situations. If an etiological cause is not present, this phenomenon is called cryptogenic OP. Secondary OP is associated with various diseases that are known to induce the OP. Objectives The aim of this study was to evaluate the clinical features of the cases with OP and compare the patients diagnosed by bronchoscopic transbronchial biopsy with patients diagnosed by surgical lung biopsy. Patients and methods Medical records of 41 patients diagnosed with OP between 2004 and 2014 were reviewed retrospectively. Results Totally, 41 patients with OP were identified. In all, 39.02% of the cases were diagnosed by bronchoscopic methods, and 60.97% of the cases were diagnosed by surgical procedures. Although the frequency of ground glass opacities, consolidations, and micronodules was higher in the group diagnosed by bronchoscopy, mass-like lesions were more common in the cases diagnosed by surgery. Bronchoscopy, performed in 30 patients totally, had a diagnostic efficacy of 53.33%. Diagnostic value of bronchoscopy was significantly higher in cryptogenic OPs. Although diffuse radiological pattern was more common in “successful bronchoscopy” group, frequency of focal pattern was higher in “failed bronchoscopy” group. Ground glass opacity in successful bronchoscopy group and mass-like lesions in failed bronchoscopy group reached significant differences. Conclusion There were significant differences between the diagnostic procedures in terms of radiological patterns. This is the first study about the relationship between the diagnostic methods and the characteristics of OP. PMID:27713632

  5. Development of laser noninvasive on-line diagnostics of oncological diseases based on the absorption method in the 4860-4880 cm-1 spectral range

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Shnyrev, S. L.; Kondrashov, A. A.

    2016-07-01

    A novel method for noninvasive on-line diagnostics of gastrointestinal oncological diseases using a diode laser in the 4860-4880 cm-1 frequency range is proposed. The method is based on measuring the concentration of 13C during expiration. The accuracy of the method allows performing early diagnostics of diseases.

  6. Development of laser noninvasive on-line diagnostics of oncological diseases based on the absorption method in the 4860–4880 cm‑1 spectral range

    NASA Astrophysics Data System (ADS)

    Kireev, S. V.; Shnyrev, S. L.; Kondrashov, A. A.

    2016-07-01

    A novel method for noninvasive on-line diagnostics of gastrointestinal oncological diseases using a diode laser in the 4860–4880 cm‑1 frequency range is proposed. The method is based on measuring the concentration of 13С during expiration. The accuracy of the method allows performing early diagnostics of diseases.

  7. An evaluation of the diagnostic efficacy of fine needle aspiration biopsy in patients operated for a thyroid nodular goiter

    PubMed Central

    Janczak, Dariusz; Pawlowski, Wiktor; Dorobisz, Tadeusz; Janczak, Dawid; Dorobisz, Karolina; Leśniak, Michal; Ziomek, Agnieszka; Chabowski, Mariusz

    2016-01-01

    Background Thyroid cancer (TC) comprises 1% of all carcinomas and is the most common malignancy of the endocrine system. The disease is more common in women, with its peak morbidity observed in 40–50-year-old patients. The main risk factors include radiation, iodine deficiency, hereditary background, and genetic mutations. Among all diagnosed thyroid nodules, 5%–30% will evolve into cancer. The gold-standard procedure in the preoperative evaluation of a nodular goiter, apart from ultrasonography, is fine needle aspiration (FNA) biopsy. The FNA biopsy is favored for its simplicity, safety, and high specificity and sensitivity rates. Aim The aim of our study was to evaluate the clinical efficacy of FNA based on the patients’ register. Materials and methods In the Department of Surgery at the 4th Military Teaching Hospital in Wroclaw, 2,133 patients underwent thyroid surgery for thyroid goiter between 1996 and 2015. One hundred and eight cases of TC were diagnosed and of these, 66 patients had a preoperative FNA. Results Fourteen FNA biopsies (21%) revealed cancer, all of which were confirmed in the postoperative histopathology, although six cases of FNA-diagnosed cancer revealed a different histological type postoperatively. Eighteen FNA biopsies (27%) were suspected of being malignant. A disturbingly high rate of “benign” FNA biopsies (32 cases; 48%) revealed TC after surgery. Conclusion It is of great importance that the quality and quantity of FNA biopsies that are performed have been improved, especially due to the wide adoption of the Bethesda cytological evaluation system. FNA biopsy remains an obligatory and valuable diagnostic tool in thyroid nodules, but it is still insufficient as a standard procedure. A preoperative biopsy should always be related to all the available clinical data in order to provide the best treatment option for each patient individually. PMID:27703381

  8. Breast Microcalcifications: Diagnostic Outcomes According to Image-Guided Biopsy Method

    PubMed Central

    Bae, Sohi; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Min Jung

    2015-01-01

    Objective To evaluate the diagnostic outcomes of ultrasonography-guided core needle biopsy (US-CNB), US-guided vacuum-assisted biopsy (US-VAB), and stereotactic-guided vacuum-assisted biopsy (S-VAB) for diagnosing suspicious breast microcalcification. Materials and Methods We retrospectively reviewed 336 cases of suspicious breast microcalcification in patients who subsequently underwent image-guided biopsy. US-CNB was performed for US-visible microcalcifications associated with a mass (n = 28), US-VAB for US-visible microcalcifications without an associated mass (n = 59), and S-VAB for mammogram-only visible lesions (n = 249). Mammographic findings, biopsy failure rate, false-negative rate, and underestimation rate were analyzed. Histological diagnoses and the Breast Imaging Reporting and Data System (BI-RADS) categories were reported. Results Biopsy failure rates for US-CNB, US-VAB, and S-VAB were 7.1% (2/28), 0% (0/59), and 2.8% (7/249), respectively. Three false-negative cases were detected for US-CNB and two for S-VAB. The rates of biopsy-diagnosed ductal carcinoma in situ that were upgraded to invasive cancer at surgery were 41.7% (5/12), 12.9% (4/31), and 8.6% (3/35) for US-CNB, US-VAB, and S-VAB, respectively. Sonographically visible lesions were more likely to be malignant (66.2% [51/77] vs. 23.2% [46/198]; p < 0.001) or of higher BI-RADS category (61.0% [47/77] vs. 22.2% [44/198]; p < 0.001) than sonographically invisible lesions. Conclusion Ultrasonography-guided vacuum-assisted biopsy is more accurate than US-CNB when suspicious microcalcifications are detected on US. Calcifications with malignant pathology are significantly more visible on US than benign lesions. PMID:26357494

  9. A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment

    SciTech Connect

    Gribble, R.

    1993-06-01

    A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described.

  10. Atomic Resonance Radiation Energetics Investigation as a Diagnostic Method for Non-Equilibrium Hypervelocity Flows

    NASA Technical Reports Server (NTRS)

    Meyer, Scott A.; Bershader, Daniel; Sharma, Surendra P.; Deiwert, George S.

    1996-01-01

    Absorption measurements with a tunable vacuum ultraviolet light source have been proposed as a concentration diagnostic for atomic oxygen, and the viability of this technique is assessed in light of recent measurements. The instrumentation, as well as initial calibration measurements, have been reported previously. We report here additional calibration measurements performed to study the resonance broadening line shape for atomic oxygen. The application of this diagnostic is evaluated by considering the range of suitable test conditions and requirements, and by identifying issues that remain to be addressed.

  11. A temporally and spatially resolved electron density diagnostic method for the edge plasma based on Stark broadening

    NASA Astrophysics Data System (ADS)

    Zafar, A.; Martin, E. H.; Shannon, S. C.; Isler, R. C.; Caughman, J. B. O.

    2016-11-01

    An electron density diagnostic (≥1010 cm-3) capable of high temporal (ms) and spatial (mm) resolution is currently under development at Oak Ridge National Laboratory. The diagnostic is based on measuring the Stark broadened, Doppler-free spectral line profile of the n = 6-2 hydrogen Balmer series transition. The profile is then fit to a fully quantum mechanical model including the appropriate electric and magnetic field operators. The quasi-static approach used to calculate the Doppler-free spectral line profile is outlined here and the results from the model are presented for H-δ spectra for electron densities of 1010-1013 cm-3. The profile shows complex behavior due to the interaction between the magnetic substates of the atom.

  12. Studies of the physical aspects of intumescence using advance diagnostics methods

    NASA Astrophysics Data System (ADS)

    Saeed, Hussain; Huang, Hua Wei; Zhang, Yang

    2014-04-01

    The use of intumescent paints as an active fire protection method has gained immense interest in recent years. A significant aspect of research has focused on studying the chemical aspects of the system to improve performance. The dynamics and physical aspects of intumescence in real time fire conditions are still unclear. The present research uses an experimental approach where diagnostics techniques such as thermal imaging camera was used to study intumescent characteristics that have been not been reported in great detail. T-panels are a substitute to the most commonly used part in construction, the I-beam. Studies were conducted using a cone calorimeter that provided a uniform heat flux through radiation on steel T-panel samples. The complex nature of char movement was recorded and a novel algorithm was used to track the growing char laye07r. The samples are designed to cater to different fire conditions. Therefore, the degree of intumescence was observed to be very different in the samples. The samples designed for low temperature cellulosic fires focus on high degree of intumesce. Whereas, mechanical strength is the focus for samples used in high temperature turbulent hydrocarbon fire conditions. The variation in the internal structure of the sample is presented. Furthermore, the phenomenon is phase shift is discussed. The phase shift is an essential part of the process of intumescence when the majority of intumescence occurs. It was observed to be different in all the samples. The movement of the samples is a property of great interest. This is because if any part of the substrate is exposed then the formulation does not meet strict commercialisation criterion. The movement was diagonal in nature as compared to flat panels where it is perpendicular. This is due tot the heating pattern of the plate that results in the web part of the panel to influence the growth of char on the flange part of the panel. A special case of char cracking is also highlighted and

  13. Studies of the physical aspects of intumescence using advance diagnostics methods

    SciTech Connect

    Saeed, Hussain Huang, Hua Wei Zhang, Yang

    2014-04-11

    The use of intumescent paints as an active fire protection method has gained immense interest in recent years. A significant aspect of research has focused on studying the chemical aspects of the system to improve performance. The dynamics and physical aspects of intumescence in real time fire conditions are still unclear. The present research uses an experimental approach where diagnostics techniques such as thermal imaging camera was used to study intumescent characteristics that have been not been reported in great detail. T-panels are a substitute to the most commonly used part in construction, the I-beam. Studies were conducted using a cone calorimeter that provided a uniform heat flux through radiation on steel T-panel samples. The complex nature of char movement was recorded and a novel algorithm was used to track the growing char laye07r. The samples are designed to cater to different fire conditions. Therefore, the degree of intumescence was observed to be very different in the samples. The samples designed for low temperature cellulosic fires focus on high degree of intumesce. Whereas, mechanical strength is the focus for samples used in high temperature turbulent hydrocarbon fire conditions. The variation in the internal structure of the sample is presented. Furthermore, the phenomenon is phase shift is discussed. The phase shift is an essential part of the process of intumescence when the majority of intumescence occurs. It was observed to be different in all the samples. The movement of the samples is a property of great interest. This is because if any part of the substrate is exposed then the formulation does not meet strict commercialisation criterion. The movement was diagonal in nature as compared to flat panels where it is perpendicular. This is due tot the heating pattern of the plate that results in the web part of the panel to influence the growth of char on the flange part of the panel. A special case of char cracking is also highlighted and

  14. Data Mining Methods Applied to Flight Operations Quality Assurance Data: A Comparison to Standard Statistical Methods

    NASA Technical Reports Server (NTRS)

    Stolzer, Alan J.; Halford, Carl

    2007-01-01

    In a previous study, multiple regression techniques were applied to Flight Operations Quality Assurance-derived data to develop parsimonious model(s) for fuel consumption on the Boeing 757 airplane. The present study examined several data mining algorithms, including neural networks, on the fuel consumption problem and compared them to the multiple regression results obtained earlier. Using regression methods, parsimonious models were obtained that explained approximately 85% of the variation in fuel flow. In general data mining methods were more effective in predicting fuel consumption. Classification and Regression Tree methods reported correlation coefficients of .91 to .92, and General Linear Models and Multilayer Perceptron neural networks reported correlation coefficients of about .99. These data mining models show great promise for use in further examining large FOQA databases for operational and safety improvements.

  15. Pressurized reactor system and a method of operating the same

    DOEpatents

    Isaksson, Juhani M.

    1996-01-01

    A method and apparatus are provided for operating a pressurized reactor system in order to precisely control the temperature within a pressure vessel in order to minimize condensation of corrosive materials from gases on the surfaces of the pressure vessel or contained circulating fluidized bed reactor, and to prevent the temperature of the components from reaching a detrimentally high level, while at the same time allowing quick heating of the pressure vessel interior volume during start-up. Superatmospheric pressure gas is introduced from the first conduit into the fluidized bed reactor and heat derived reactions such as combustion and gassification are maintained in the reactor. Gas is exhausted from the reactor and pressure vessel through a second conduit. Gas is circulated from one part of the inside volume to another to control the temperature of the inside volume, such as by passing the gas through an exterior conduit which has a heat exchanger, control valve, blower and compressor associated therewith, or by causing natural convection flow of circulating gas within one or more generally vertically extending gas passages entirely within the pressure vessel (and containing heat exchangers, flow rate control valves, or the like therein). Preferably, inert gas is provided as a circulating gas, and the inert gas may also be used in emergency shut-down situations. In emergency shut-down reaction gas being supplied to the reactor is cut off, while inert gas from the interior gas volume of the pressure vessel is introduced into the reactor.

  16. Pressurized reactor system and a method of operating the same

    DOEpatents

    Isaksson, J.M.

    1996-06-18

    A method and apparatus are provided for operating a pressurized reactor system in order to precisely control the temperature within a pressure vessel in order to minimize condensation of corrosive materials from gases on the surfaces of the pressure vessel or contained circulating fluidized bed reactor, and to prevent the temperature of the components from reaching a detrimentally high level, while at the same time allowing quick heating of the pressure vessel interior volume during start-up. Super-atmospheric pressure gas is introduced from the first conduit into the fluidized bed reactor and heat derived reactions such as combustion and gasification are maintained in the reactor. Gas is exhausted from the reactor and pressure vessel through a second conduit. Gas is circulated from one part of the inside volume to another to control the temperature of the inside volume, such as by passing the gas through an exterior conduit which has a heat exchanger, control valve, blower and compressor associated therewith, or by causing natural convection flow of circulating gas within one or more generally vertically extending gas passages entirely within the pressure vessel (and containing heat exchangers, flow rate control valves, or the like therein). Preferably, inert gas is provided as a circulating gas, and the inert gas may also be used in emergency shut-down situations. In emergency shut-down reaction gas being supplied to the reactor is cut off, while inert gas from the interior gas volume of the pressure vessel is introduced into the reactor. 2 figs.

  17. Diagnostic methods for mastitis in cows are not appropriate for use in humans: commentary.

    PubMed

    Kvist, Linda J

    2016-01-01

    Healthcare workers are now being targeted for marketing of diagnostic tools for mastitis that were developed for the dairy industry and which aim to provide information regarding choice of antibiotic treatment. Meanwhile, scientists are striving to understand how the human microbiome affects health and wellbeing and the importance of maintenance of bacterial balance in the human body. Breast milk supplies a multitude of bacteria to populate the baby's intestinal tract and kick-start the immune system. Researchers propose a paradigm shift in the understanding of bacterial content in breast milk and an alternative paradigm for the understanding of lactational mastitis: there is the beginning of evidence that many cases of lactational mastitis will resolve spontaneously. An international group of researchers is attempting to answer how dietary habits, birth mode, genetics and environmental factors may impact the bacterial content of breast milk. Until we have more comprehensive knowledge about the human milk microbiome, diagnostic aids for identification of women in need of antibiotic therapy for mastitis remain unreliable. Diagnostic aids could lead to the injudicious use of antibiotic therapy, which in turn may rob the infant of bacteria valuable for development of its immune system. The marketing of diagnostic aids for use in human medicine, that were originally developed for use in cows, is neither evidence-based nor good ethical practice. PMID:26877759

  18. Mutual Information Item Selection Method in Cognitive Diagnostic Computerized Adaptive Testing with Short Test Length

    ERIC Educational Resources Information Center

    Wang, Chun

    2013-01-01

    Cognitive diagnostic computerized adaptive testing (CD-CAT) purports to combine the strengths of both CAT and cognitive diagnosis. Cognitive diagnosis models aim at classifying examinees into the correct mastery profile group so as to pinpoint the strengths and weakness of each examinee whereas CAT algorithms choose items to determine those…

  19. Personality Assessment in the Diagnostic Manuals: On Mindfulness, Multiple Methods, and Test Score Discontinuities.

    PubMed

    Bornstein, Robert F

    2015-01-01

    Recent controversies have illuminated the strengths and limitations of different frameworks for conceptualizing personality pathology (e.g., trait perspectives, categorical models), and stimulated debate regarding how best to diagnose personality disorders (PDs) in the Diagnostic and Statistical Manual of Mental Disorders (5th ed.), and in other diagnostic systems (i.e., the International Classification of Diseases, the Psychodynamic Diagnostic Manual). In this article I argue that regardless of how PDs are conceptualized and which diagnostic system is employed, multimethod assessment must play a central role in PD diagnosis. By complementing self-reports with evidence from other domains (e.g., performance-based tests), a broader range of psychological processes are engaged in the patient, and the impact of self-perception and self-presentation biases can be better understood. By providing the assessor with evidence drawn from multiple modalities, some of which provide converging patterns and some of which yield divergent results, a multimethod assessment compels the assessor to engage this evidence more deeply. The mindful processing that ensues can help minimize the deleterious impact of naturally occurring information processing bias and distortion on the part of the clinician (e.g., heuristics, attribution errors), bringing greater clarity to the synthesis and integration of assessment data.

  20. Towards a rapid molecular diagnostic for melioidosis: Comparison of DNA extraction methods from clinical specimens.

    PubMed

    Richardson, Leisha J; Kaestli, Mirjam; Mayo, Mark; Bowers, Jolene R; Tuanyok, Apichai; Schupp, Jim; Engelthaler, David; Wagner, David M; Keim, Paul S; Currie, Bart J

    2012-01-01

    Optimising DNA extraction from clinical samples for Burkholderia pseudomallei Type III secretion system real-time PCR in suspected melioidosis patients confirmed that urine and sputum are useful diagnostic samples. Direct testing on blood remains problematic; testing DNA extracted from plasma was superior to DNA from whole blood or buffy coat.

  1. An Informal Reading Readiness Inventory: A Diagnostic Method of Predicting First Grade Reading Achievement.

    ERIC Educational Resources Information Center

    Anderson, Carolyn C.; Koenke, Karl

    A study was undertaken to create and validate a diagnostic, task-based Informal Reading Readiness Inventory (IRRI). IRRI subtests were created to reflect four areas found to be important in reading readiness: awareness of self and media, language experience, reasoning, and phonics. Prereading curriculum components formed the basis for test item…

  2. Multi-Reader Multi-Case Studies Using the Area under the Receiver Operator Characteristic Curve as a Measure of Diagnostic Accuracy: Systematic Review with a Focus on Quality of Data Reporting

    PubMed Central

    Dendumrongsup, Thaworn; Plumb, Andrew A.; Halligan, Steve; Fanshawe, Thomas R.; Altman, Douglas G.; Mallett, Susan

    2014-01-01

    Introduction We examined the design, analysis and reporting in multi-reader multi-case (MRMC) research studies using the area under the receiver-operating curve (ROC AUC) as a measure of diagnostic performance. Methods We performed a systematic literature review from 2005 to 2013 inclusive to identify a minimum 50 studies. Articles of diagnostic test accuracy in humans were identified via their citation of key methodological articles dealing with MRMC ROC AUC. Two researchers in consensus then extracted information from primary articles relating to study characteristics and design, methods for reporting study outcomes, model fitting, model assumptions, presentation of results, and interpretation of findings. Results were summarized and presented with a descriptive analysis. Results Sixty-four full papers were retrieved from 475 identified citations and ultimately 49 articles describing 51 studies were reviewed and extracted. Radiological imaging was the index test in all. Most studies focused on lesion detection vs. characterization and used less than 10 readers. Only 6 (12%) studies trained readers in advance to use the confidence scale used to build the ROC curve. Overall, description of confidence scores, the ROC curve and its analysis was often incomplete. For example, 21 (41%) studies presented no ROC curve and only 3 (6%) described the distribution of confidence scores. Of 30 studies presenting curves, only 4 (13%) presented the data points underlying the curve, thereby allowing assessment of extrapolation. The mean change in AUC was 0.05 (−0.05 to 0.28). Non-significant change in AUC was attributed to underpowering rather than the diagnostic test failing to improve diagnostic accuracy. Conclusions Data reporting in MRMC studies using ROC AUC as an outcome measure is frequently incomplete, hampering understanding of methods and the reliability of results and study conclusions. Authors using this analysis should be encouraged to provide a full description of

  3. The Diagnostic Method of Inner Parts of Welded Joints at Nuclear Power Plant

    SciTech Connect

    Bednarova, O.; Janovec, J.

    2010-06-22

    There is no possibility to check any inner part at real welded joint at nuclear power station (NPS) during operation because any destructive test cannot be used. In practice there is checked surface of weld. There are used four methodical instructions for the check of real welds: 1. The visual inspection, 2. The measurement of hardness, 3. The chemical composition checking and 4. The microstructure replica analysis. It is necessary to know how these information of weld surface are in accordance with characteristics of inner parts of weld. If there is not any difference between surface weld microstructure and internal weld microstructure of experimental weld it is supposed to that there is not any difference in other measured properties of welds. If is changed structural characteristics of microstructure, it is changed also hardness, chemical analysis etc. It was observed that the microstructure of real welds is almost the same with simulated weld and also the surface microstructure of experimental weld is in accordance with microstructure of inner parts of this weld. It can be supposed extension of lifetime of NPS if there is not any difference between replicas microstructure taken after six year operation of NPS and microstructure of inner parts of simulated weld is almost the same with surface microstructure.

  4. Memory alloy heat engine and method of operation

    DOEpatents

    Johnson, Alfred Davis

    1977-01-01

    A heat engine and method of operation employing an alloy having a shape memory effect. A memory alloy element such as one or more wire loops are cyclically moved through a heat source, along a path toward a heat sink, through the heat sink and then along another path in counter-flow heat exchange relationship with the wire in the first path. The portion of the wire along the first path is caused to elongate to its trained length under minimum tension as it is cooled. The portion of the wire along the second path is caused to contract under maximum tension as it is heated. The resultant tension differential between the wires in the two paths is applied as a force through a distance to produce mechanical work. In one embodiment a first set of endless memory alloy wires are reeved in non-slip engagement between a pair of pulleys which are mounted for conjoint rotation within respective hot and cold reservoirs. Another set of endless memory alloy wires are reeved in non-slip engagement about another pair of pulleys which are mounted in the respective hot and cold reservoirs. The pulleys in the cold reservoir are of a larger diameter than those in the hot reservoir and the opposite reaches of the wires between the two sets of pulleys extend in closely spaced-apart relationship in counter-flow heat regenerator zones. The pulleys are turned to move the two sets of wires in opposite directions. The wires are stretched as they are cooled upon movement through the heat regenerator toward the cold reservoirs, and the wires contract as they are heated upon movement through the regenerator zones toward the hot reservoir. This contraction of wires exerts a larger torque on the greater diameter pulleys for turning the pulleys and supplying mechanical power. Means is provided for applying a variable tension to the wires. Phase change means is provided for controlling the angular phase of the pulleys of each set for purposes of start up procedure as well as for optimizing engine

  5. Physics-Based Methods of Failure Analysis and Diagnostics in Human Space Flight

    NASA Technical Reports Server (NTRS)

    Smelyanskiy, Vadim N.; Luchinsky, Dmitry Georgievich; Hafiychuk, Vasyl Nmn; Osipov, Viatcheslav V.; Patterson-Hine, F. Ann

    2010-01-01

    The Integrated Health Management (IHM) for the future aerospace systems requires to interface models of multiple subsystems in an efficient and accurate information environment at the earlier stages of system design. The complexity of modern aeronautic and aircraft systems (including e.g. the power distribution, flight control, solid and liquid motors) dictates employment of hybrid models and high-level reasoners for analysing mixed continuous and discrete information flow involving multiple modes of operation in uncertain environments, unknown state variables, heterogeneous software and hardware components. To provide the information link between key design/performance parameters and high-level reasoners we rely on development of multi-physics performance models, distributed sensors networks, and fault diagnostic and prognostic (FD&P) technologies in close collaboration with system designers. The main challenges of our research are related to the in-flight assessment of the structural stability, engine performance, and trajectory control. The main goal is to develop an intelligent IHM that not only enhances components and system reliability, but also provides a post-flight feedback helping to optimize design of the next generation of aerospace systems. Our efforts are concentrated on several directions of the research. One of the key components of our strategy is an innovative approach to the diagnostics/prognostics based on the real time dynamical inference (DI) technologies extended to encompass hybrid systems with hidden state trajectories. The major investments are into the multiphysics performance modelling that provides an access of the FD&P technologies to the main performance parameters of e.g. solid and liquid rocket motors and composite materials of the nozzle and case. Some of the recent results of our research are discussed in this chapter. We begin by introducing the problem of dynamical inference of stochastic nonlinear models and reviewing earlier

  6. 12 CFR 1102.303 - Organization and methods of operation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ....S.C. 3310, 3333 and 3334. The ASC has adopted and published Rules of Operation guiding its administration, meetings and procedures. These Rules of Operation were published at 56 FR 28561 (June 21, 1991... Union Administration, Office of Thrift Supervision, and the Department of Housing and Urban...

  7. Tools for Evaluating Fault Detection and Diagnostic Methods for HVAC Secondary Systems

    NASA Astrophysics Data System (ADS)

    Pourarian, Shokouh

    Although modern buildings are using increasingly sophisticated energy management and control systems that have tremendous control and monitoring capabilities, building systems routinely fail to perform as designed. More advanced building control, operation, and automated fault detection and diagnosis (AFDD) technologies are needed to achieve the goal of net-zero energy commercial buildings. Much effort has been devoted to develop such technologies for primary heating ventilating and air conditioning (HVAC) systems, and some secondary systems. However, secondary systems, such as fan coil units and dual duct systems, although widely used in commercial, industrial, and multifamily residential buildings, have received very little attention. This research study aims at developing tools that could provide simulation capabilities to develop and evaluate advanced control, operation, and AFDD technologies for these less studied secondary systems. In this study, HVACSIM+ is selected as the simulation environment. Besides developing dynamic models for the above-mentioned secondary systems, two other issues related to the HVACSIM+ environment are also investigated. One issue is the nonlinear equation solver used in HVACSIM+ (Powell's Hybrid method in subroutine SNSQ). It has been found from several previous research projects (ASRHAE RP 825 and 1312) that SNSQ is especially unstable at the beginning of a simulation and sometimes unable to converge to a solution. Another issue is related to the zone model in the HVACSIM+ library of components. Dynamic simulation of secondary HVAC systems unavoidably requires an interacting zone model which is systematically and dynamically interacting with building surrounding. Therefore, the accuracy and reliability of the building zone model affects operational data generated by the developed dynamic tool to predict HVAC secondary systems function. The available model does not simulate the impact of direct solar radiation that enters a zone

  8. Tools for Evaluating Fault Detection and Diagnostic Methods for HVAC Secondary Systems

    NASA Astrophysics Data System (ADS)

    Pourarian, Shokouh

    Although modern buildings are using increasingly sophisticated energy management and control systems that have tremendous control and monitoring capabilities, building systems routinely fail to perform as designed. More advanced building control, operation, and automated fault detection and diagnosis (AFDD) technologies are needed to achieve the goal of net-zero energy commercial buildings. Much effort has been devoted to develop such technologies for primary heating ventilating and air conditioning (HVAC) systems, and some secondary systems. However, secondary systems, such as fan coil units and dual duct systems, although widely used in commercial, industrial, and multifamily residential buildings, have received very little attention. This research study aims at developing tools that could provide simulation capabilities to develop and evaluate advanced control, operation, and AFDD technologies for these less studied secondary systems. In this study, HVACSIM+ is selected as the simulation environment. Besides developing dynamic models for the above-mentioned secondary systems, two other issues related to the HVACSIM+ environment are also investigated. One issue is the nonlinear equation solver used in HVACSIM+ (Powell's Hybrid method in subroutine SNSQ). It has been found from several previous research projects (ASRHAE RP 825 and 1312) that SNSQ is especially unstable at the beginning of a simulation and sometimes unable to converge to a solution. Another issue is related to the zone model in the HVACSIM+ library of components. Dynamic simulation of secondary HVAC systems unavoidably requires an interacting zone model which is systematically and dynamically interacting with building surrounding. Therefore, the accuracy and reliability of the building zone model affects operational data generated by the developed dynamic tool to predict HVAC secondary systems function. The available model does not simulate the impact of direct solar radiation that enters a zone

  9. The development of malaria diagnostic techniques: a review of the approaches with focus on dielectrophoretic and magnetophoretic methods.

    PubMed

    Kasetsirikul, Surasak; Buranapong, Jirayut; Srituravanich, Werayut; Kaewthamasorn, Morakot; Pimpin, Alongkorn

    2016-01-01

    The large number of deaths caused by malaria each year has increased interest in the development of effective malaria diagnoses. At the early-stage of infection, patients show non-specific symptoms or are asymptomatic, which makes it difficult for clinical diagnosis, especially in non-endemic areas. Alternative diagnostic methods that are timely and effective are required to identify infections, particularly in field settings. This article reviews conventional malaria diagnostic methods together with recently developed techniques for both malaria detection and infected erythrocyte separation. Although many alternative techniques have recently been proposed and studied, dielectrophoretic and magnetophoretic approaches are among the promising new techniques due to their high specificity for malaria parasite-infected red blood cells. The two approaches are discussed in detail, including their principles, types, applications and limitations. In addition, other recently developed techniques, such as cell deformability and morphology, are also overviewed in this article. PMID:27405995

  10. Apparatus and method for grounding compressed fuel fueling operator

    DOEpatents

    Cohen, Joseph Perry; Farese, David John; Xu, Jianguo

    2002-06-11

    A safety system for grounding an operator at a fueling station prior to removing a fuel fill nozzle from a fuel tank upon completion of a fuel filling operation is provided which includes a fuel tank port in communication with the fuel tank for receiving and retaining the nozzle during the fuel filling operation and a grounding device adjacent to the fuel tank port which includes a grounding switch having a contact member that receives physical contact by the operator and where physical contact of the contact member activates the grounding switch. A releasable interlock is included that provides a lock position wherein the nozzle is locked into the port upon insertion of the nozzle into the port and a release position wherein the nozzle is releasable from the port upon completion of the fuel filling operation and after physical contact of the contact member is accomplished.

  11. Raman spectroscopy of saliva as a perspective method for periodontitis diagnostics Raman spectroscopy of saliva

    NASA Astrophysics Data System (ADS)

    Gonchukov, S.; Sukhinina, A.; Bakhmutov, D.; Minaeva, S.

    2012-01-01

    In view of its potential for biological tissues analyses at a molecular level, Raman spectroscopy in optical range has been the object of biomedical research for the last years. The main aim of this work is the development of Raman spectroscopy for organic content identifying and determination of biomarkers of saliva at a molecular level for periodontitis diagnostics. Four spectral regions were determined: 1155 and 1525 cm-1, 1033 and 1611 cm-1, which can be used as biomarkers of this widespread disease.

  12. A Refined QSO Selection Method Using Diagnostics Tests: 663 QSO Candidates in the Large Magellanic Cloud

    NASA Astrophysics Data System (ADS)

    Kim, Dae-Won; Protopapas, Pavlos; Trichas, Markos; Rowan-Robinson, Michael; Khardon, Roni; Alcock, Charles; Byun, Yong-Ik

    2012-03-01

    We present 663 QSO candidates in the Large Magellanic Cloud (LMC) selected using multiple diagnostics. We started with a set of 2566 QSO candidates selected using the methodology presented in our previous work based on time variability of the MACHO LMC light curves. We then obtained additional information for the candidates by crossmatching them with the Spitzer SAGE, the Two Micron All Sky Survey, the Chandra, the XMM, and an LMC UBVI catalog. Using this information, we specified six diagnostic features based on mid-IR colors, photometric redshifts using spectral energy distribution template fitting, and X-ray luminosities in order to further discriminate high-confidence QSO candidates in the absence of spectra information. We then trained a one-class Support Vector Machine model using the diagnostics features of the confirmed 58 MACHO QSOs. We applied the trained model to the original candidates and finally selected 663 high-confidence QSO candidates. Furthermore, we crossmatched these 663 QSO candidates with the newly confirmed 151 QSOs and 275 non-QSOs in the LMC fields. On the basis of the counterpart analysis, we found that the false positive rate is less than 1%.

  13. A REFINED QSO SELECTION METHOD USING DIAGNOSTICS TESTS: 663 QSO CANDIDATES IN THE LARGE MAGELLANIC CLOUD

    SciTech Connect

    Kim, Dae-Won; Protopapas, Pavlos; Trichas, Markos; Alcock, Charles; Rowan-Robinson, Michael; Khardon, Roni; Byun, Yong-Ik

    2012-03-10

    We present 663 QSO candidates in the Large Magellanic Cloud (LMC) selected using multiple diagnostics. We started with a set of 2566 QSO candidates selected using the methodology presented in our previous work based on time variability of the MACHO LMC light curves. We then obtained additional information for the candidates by crossmatching them with the Spitzer SAGE, the Two Micron All Sky Survey, the Chandra, the XMM, and an LMC UBVI catalog. Using this information, we specified six diagnostic features based on mid-IR colors, photometric redshifts using spectral energy distribution template fitting, and X-ray luminosities in order to further discriminate high-confidence QSO candidates in the absence of spectra information. We then trained a one-class Support Vector Machine model using the diagnostics features of the confirmed 58 MACHO QSOs. We applied the trained model to the original candidates and finally selected 663 high-confidence QSO candidates. Furthermore, we crossmatched these 663 QSO candidates with the newly confirmed 151 QSOs and 275 non-QSOs in the LMC fields. On the basis of the counterpart analysis, we found that the false positive rate is less than 1%.

  14. Survey of methods for improving operator acceptance of computerized aids

    SciTech Connect

    Frey, P. R.; Kisner, R. A.

    1982-04-01

    The success of current attempts to improve the operational performance and safety of nuclear power plants by installing computerized operational aids in the control rooms is dependent, in part, on the operator's attitude toward the aid. Utility experience with process computer systems indicates that problems may already exist with operator acceptance of computerized aids. The growth of the role that computers have in nuclear power plants makes user acceptance of computer technology an important issue for the nuclear industry. The purpose of this report is to draw from the literature factors related to user acceptance of computerized equipment that may also be applicable to the acceptance of computerized aids used in the nuclear power plant control room.

  15. Classification and uptake of reservoir operation optimization methods

    NASA Astrophysics Data System (ADS)

    Dobson, Barnaby; Pianosi, Francesca; Wagener, Thorsten

    2016-04-01

    Reservoir operation optimization algorithms aim to improve the quality of reservoir release and transfer decisions. They achieve this by creating and optimizing the reservoir operating policy; a function that returns decisions based on the current system state. A range of mathematical optimization algorithms and techniques has been applied to the reservoir operation problem of policy optimization. In this work, we propose a classification of reservoir optimization approaches by focusing on the formulation of the water management problem rather than the optimization algorithm type. We believe that decision makers and operators will find it easier to navigate a classification system based on the problem characteristics, something they can clearly define, rather than the optimization algorithm. Part of this study includes an investigation regarding the extent of algorithm uptake and the possible reasons that limit real world application.

  16. Quench monitoring and control system and method of operating same

    DOEpatents

    Ryan, David Thomas; Laskaris, Evangelos Trifon; Huang, Xianrui

    2006-05-30

    A rotating machine comprising a superconductive coil and a temperature sensor operable to provide a signal representative of superconductive coil temperature. The rotating machine may comprise a control system communicatively coupled to the temperature sensor. The control system may be operable to reduce electric current in the superconductive coil when a signal representative of a defined superconducting coil temperature is received from the temperature sensor.

  17. Investigating the Nature of and Methods for Managing Metroplex Operations

    NASA Technical Reports Server (NTRS)

    Atkins, Stephen; Capozzi, Brian; Hinkey, Jim; Idris, Husni; Kaiser, Kent

    2011-01-01

    A combination of traffic demand growth, Next Generation Air Transportation System (NextGen) technologies and operational concepts, and increased utilization of regional airports is expected to increase the occurrence and severity of coupling between operations at proximate airports. These metroplex phenomena constrain the efficiency and/or capacity of airport operations and, in NextGen, have the potential to reduce safety and prevent environmental benefits. Without understanding the nature of metroplexes and developing solutions that provide efficient coordination of operations between closely-spaced airports, the use of NextGen technologies and distribution of demand to regional airports may provide little increase in the overall metroplex capacity. However, the characteristics and control of metroplex operations have not received significant study. This project advanced the state of knowledge about metroplexes by completing three objectives: 1. developed a foundational understand of the nature of metroplexes; 2. provided a framework for discussing metroplexes; 3. suggested and studied an approach for optimally managing metroplexes that is consistent with other NextGen concepts

  18. Diagnostic Laparoscopy in the Pre-operative Assessment of Patients Undergoing Cytoreductive Surgery and HIPEC for Peritoneal Surface Malignancies.

    PubMed

    Seshadri, Ramakrishnan Ayloor; Hemanth Raj E

    2016-06-01

    The introduction of cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) has led to an improvement in the survival of select patients with peritoneal surface malignancies (PSM). However, it is important to carefully identify patients who will benefit from this procedure and to avoid an unnecessary laparotomy in those who will not. The currently available imaging modalities are unable to accurately predict the peritoneal cancer index (PCI) score or the completeness of cytoreduction. In this article, we review the current status of staging laparoscopy in the assessment of patients with PSM who are planned for CRS & HIPEC. We discuss the patient selection, techniques, complications and efficacy of staging laparoscopy. To summarise, staging laparoscopy is a safe and feasible method of pre-operative assessment of patients with PSM. It has a high sensitivity and positive predictive value in identifying patients who can undergo a complete cytoreduction, thereby preventing many patients from undergoing an unnecessary laparotomy. With the exception of pseudomyxoma peritonei, it should be considered as a part of the routine assessment of patients with PSM who are being considered for CRS & HIPEC. PMID:27065714

  19. New diagnostic method for monitoring plasma reactor walls: Multiple total internal reflection Fourier transform infrared surface probe

    NASA Astrophysics Data System (ADS)

    Godfrey, Anna R.; Ullal, Saurabh J.; Braly, Linda B.; Edelberg, Erik A.; Vahedi, Vahid; Aydil, Eray S.

    2001-08-01

    Films and adsorbates that deposit on reactor walls during plasma etching and deposition affect the discharge properties such as the charged particle and reactive radical concentrations. A systematic study of this plasma-wall interaction is made difficult by a lack of diagnostic methods that enable one to monitor the chemical nature of the reactor wall surface. A new diagnostic technique based on multiple total internal reflection Fourier transform infrared (MTIR-FTIR) spectroscopy was developed to monitor films and adsorbates on plasma etching and deposition reactor walls with monolayer sensitivity. Applications of this MTIR-FTIR probe are demonstrated. Specifically, we use this probe to (i) detect etch products and films that deposit on the reactor walls during Cl2 plasma etching of Si, (ii) determine the efficacy of a SF6 plasma to clean films deposited on reactor walls during Cl2/O2 etching of Si, and (iii) monitor wafer-to-wafer etching reproducibility.

  20. [Rapid methods for the diagnostic of food-borne infections determined by bacteria pertaining to genus Salmonella].

    PubMed

    Năşcuţiu, Alexandra-Maria

    2011-01-01

    For a long period of time, microbiological analysis of samples gathered from individuals, food and environment was based on culture techniques which were considered "gold standard". These conventional methods are yet time-consuming (with respect to germ identification and characterization), cumulative costs are huge, which made research focus on obtaining methods with a rapidity / cost ratio higher than that of classical methods. Rapid diagnostic became as well a priority in the case of food-borne diseases determined by Salmonella spp. These methods of rapid diagnostic are based on phenotypic or molecular techniques for identification and typing, as well as on tests using biosensors and DNA chips, which are under development, and which use the capacity of real-time monitoring of the presence of multiple pathogens in food. With the continuous development of new molecular technologies allowing the rapid detection of food pathogens, the future of conventional microbiological methods looks rather insecure, the more so as there is continuous interest in improving the performances of genotypic methods regarding easy handling, reliability and low costs. The work reviews the panoply of Salmonella identification and typing tests available in the present.

  1. Diagnostics for ITER

    SciTech Connect

    Donne, A. J. H.; Hellermann, M. G. von; Barnsley, R.

    2008-10-22

    After an introduction into the specific challenges in the field of diagnostics for ITER (specifically high level of nuclear radiation, long pulses, high fluxes of particles to plasma facing components, need for reliability and robustness), an overview will be given of the spectroscopic diagnostics foreseen for ITER. The paper will describe both active neutral-beam based diagnostics as well as passive spectroscopic diagnostics operating in the visible, ultra-violet and x-ray spectral regions.

  2. Diagnostic tolerance for missing sensor data

    NASA Technical Reports Server (NTRS)

    Scarl, Ethan A.

    1989-01-01

    For practical automated diagnostic systems to continue functioning after failure, they must not only be able to diagnose sensor failures but also be able to tolerate the absence of data from the faulty sensors. It is shown that conventional (associational) diagnostic methods will have combinatoric problems when trying to isolate faulty sensors, even if they adequately diagnose other components. Moreover, attempts to extend the operation of diagnostic capability past sensor failure will necessarily compound those difficulties. Model-based reasoning offers a structured alternative that has no special problems diagnosing faulty sensors and can operate gracefully when sensor data is missing.

  3. System and method of vehicle operating condition management

    SciTech Connect

    Sujan, Vivek A.; Vajapeyazula, Phani; Follen, Kenneth; Wu, An; Moffett, Barty L.

    2015-10-20

    A vehicle operating condition profile can be determined over a given route while also considering imposed constraints such as deviation from time targets, deviation from maximum governed speed limits, etc. Given current vehicle speed, engine state and transmission state, the present disclosure optimally manages the engine map and transmission to provide a recommended vehicle operating condition that optimizes fuel consumption in transitioning from one vehicle state to a target state. Exemplary embodiments provide for offline and online optimizations relative to fuel consumption. The benefit is increased freight efficiency in transporting cargo from source to destination by minimizing fuel consumption and maintaining drivability.

  4. System and method of operating toroidal magnetic confinement devices

    DOEpatents

    Chance, Morrell S.; Jardin, Stephen C.; Stix, Thomas H.; Grimm, deceased, Ray C.; Manickam, Janardhan; Okabayashi, Michio

    1987-01-01

    For toroidal magnetic confinement devices the second region of stability against ballooning modes can be accessed with controlled operation. Under certain modes of operation, the first and second stability regions may be joined together. Accessing the second region of stability is accomplished by forming a bean-shaped plasma and increasing the indentation until a critical value of indentation is reached. A pusher coil, located at the inner-major-radius side of the device, is engaged to form a bean-shaped poloidal cross-section in the plasma.

  5. [Real-time sonography of cholangiolithiasis. Dependence of the diagnostic accuracy on the competence of the operator].

    PubMed

    Schafroth, E; Saltzman, J; Probst, P

    1987-09-01

    The reliability of sonography for demonstrating bile duct stones depends on technical factors and on the experience of the operator. The pick up rate of an experienced operator has been compared with that of three other doctors who had performed sonography only briefly and intermittently. This was based on the results of surgery in 142 patients. The sensitivity of the experienced operator was 72.4% and almost twice that of the other doctors, who showed an accuracy of 37.5 and 44%. The competence of the operator depends not only on adequate training, but also on continuous practice.

  6. The Brief Introduction of Different Laser Diagnostics Methods Used in Aero-Engine Combustion Research

    NASA Astrophysics Data System (ADS)

    Xing, Fei; Song, Ge; Ruan, Can; Zhao, Jian; Yang, Yongjun

    2016-06-01

    Combustion test diagnose has always been one of the most important technologies for the development of aerospace engineering. Laser diagnostics techniques developed quickly in the past several years. They are used to measure the parameters of the combustion flow field such as velocity, temperature, components concentration with high space and time resolution and brought no disturbance. Planar Laser-Induced Fluorescence, Coherent Anti-Stokes Raman Scattering, Tunable Diode Laser Absorption Spectroscopy and Raman Scattering were introduced systemically in this paper. After analysis their own advantages and disadvantages, it is believed that Raman Scattering system is more suitable for research activities on aero-engine combustion systems.

  7. Genetic mutation underlying orthostatic intolerance and diagnostic and therapeutic methods relating thereto

    NASA Technical Reports Server (NTRS)

    Robertson, David (Inventor); Blakely, Randy D. (Inventor)

    2006-01-01

    Isolated polynucleotide molecules and peptides encoded by these molecules are used in the analysis of human norepinephrine (NE) transporter variants, as well as in diagnostic and therapeutic applications, relating to a human NE transporter polymorphism. By analyzing genomic DNA or amplified genomic DNA, or amplified cDNA derived from mRNA, it is possible to type a human NE transporter with regard to the human NE transporter polymorphism, for example, in the context of diagnosing and treating NE transport impairments, and disorders associated with NE transport impairments, such as orthostatic intolerance.

  8. ORF virus infection in children: clinical characteristics, transmission, diagnostic methods, and future therapeutics.

    PubMed

    Lederman, Edith R; Austin, Connie; Trevino, Ingrid; Reynolds, Mary G; Swanson, Holly; Cherry, Bryan; Ragsdale, Jennifer; Dunn, John; Meidl, Susan; Zhao, Hui; Li, Yu; Pue, Howard; Damon, Inger K

    2007-08-01

    Orf virus leads to self-limited, subacute cutaneous infections in children who have occupational or recreational contact with infected small ruminants. Breaches in the integument and contact with animals recently vaccinated for orf may be important risk factors in transmission. Common childhood behaviors are likely important factors in the provocation of significant contact (ie, bites) or in unusual lesion location (eg, facial lesions). Clinician recognition is important in distinguishing orf infection from life-threatening cutaneous zoonoses. Recently developed molecular techniques provide diagnostic precision and newer topical therapeutics may hasten healing.

  9. Application Research of Two Real-Time Fault Diagnostic Methods in the Nuclear Power Plants

    SciTech Connect

    Chun-Li Xie; Yong-Kuo Liu; Hong Xia

    2006-07-01

    In order to guarantee the safety of nuclear power plants (NPP), we built two real-time fault diagnosis systems adopting VISUAL BAS6.0 programming language, which apply neural network technology and data fusion technology respectively. The fault diagnosis systems interchange data with the simulator timely utilizing communication interface. We insert faults on simulator to test the two systems on line. The advantages and disadvantages are illuminated and contrasted through analyzing the faults diagnostic results off- line, which establish the foundation for the further research and application to the fault diagnosis system of the nuclear power plants. (authors)

  10. Effectiveness of Air Drying and Magnification Methods for Detecting Initial Caries on Occlusal Surfaces Using Three Different Diagnostic Aids.

    PubMed

    Goel, Deepti; Sandhu, Meera; Jhingan, Pulkit; Sachdev, Vinod

    2016-01-01

    Objective-The aim of this study was to assess the effect of magnification and air-drying on detection of carious lesion. Study Design-44 human extracted premolars were selected with sound occlusal surfaces without frank cavitation. The Diagnostic techniques used were Unaided visual examination, Magnifying Loupes (4.2×) and Stereomicroscope (10×, before and after air-drying) and then the teeth were sectioned bucco-lingually and both the surfaces were examined under Stereomicroscope (50×) to assess the presence or absence of carious lesion in the pit and fissures. The scores were compared to obtain Cohen's kappa coefficient (Reproducibility) and subjected to the Friedman Test and Paired t test. Sensitivity, specificity and positive predictive value used to assess accuracy. Results-On Statistical analysis, visual examination before and after air drying had highest specificity but lowest sensitivity compared to different diagnostic techniques. Magnifying loupes after air-drying had highest sensitivity and lowest specificity compared to other diagnostic techniques. Conclusion-Air drying combined with magnifying aids are cost-effective, reliable method for detection of early carious lesion. If used in pediatric clinical practice, any undesirable pain and discomfort to the patient due to invasive procedures and helps in employing preventive measures. PMID:27472570

  11. Cold weather hydrogen generation system and method of operation

    DOEpatents

    Dreier, Ken Wayne; Kowalski, Michael Thomas; Porter, Stephen Charles; Chow, Oscar Ken; Borland, Nicholas Paul; Goyette, Stephen Arthur

    2010-12-14

    A system for providing hydrogen gas is provided. The system includes a hydrogen generator that produces gas from water. One or more heat generation devices are arranged to provide heating of the enclosure during different modes of operation to prevent freezing of components. A plurality of temperature sensors are arranged and coupled to a controller to selectively activate a heat source if the temperature of the component is less than a predetermined temperature.

  12. Method and means for refinery gas plant operation

    SciTech Connect

    Harandi, M.N.

    1991-05-14

    This patent describes a process for operating an unsaturated gas plant of a catalytic hydrocarbon conversion process. It comprises: contacting acidic hydrocarbon feedstreams to a gas plant absorption zone comprising a least one liquid absorber bed and one vapor absorber bed upstream of the separator zone, the feedstreams comprising unstabilized liquid gasoline and liquid and vapor output streams from liquid vapor separator for inter-stage liquids and compressor effluents from the conversion process main fractionator, whereby the feedstreams are deacidified.

  13. Applications of Genetic Methods to NASA Design and Operations Problems

    NASA Technical Reports Server (NTRS)

    Laird, Philip D.

    1996-01-01

    We review four recent NASA-funded applications in which evolutionary/genetic methods are important. In the process we survey: the kinds of problems being solved today with these methods; techniques and tools used; problems encountered; and areas where research is needed. The presentation slides are annotated briefly at the top of each page.

  14. A real-time laser feedback control method for the three-wave laser source used in the polarimeter-interferometer diagnostic on Joint-TEXT tokamak

    NASA Astrophysics Data System (ADS)

    Xiong, C. Y.; Chen, J.; Li, Q.; Liu, Y.; Gao, L.

    2014-12-01

    A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (˜100-˜500 kHz/10 min) and decay of laser power (˜10%-˜20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.

  15. A real-time laser feedback control method for the three-wave laser source used in the polarimeter-interferometer diagnostic on Joint-TEXT tokamak.

    PubMed

    Xiong, C Y; Chen, J; Li, Q; Liu, Y; Gao, L

    2014-12-01

    A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (∼100-∼500 kHz/10 min) and decay of laser power (∼10%-∼20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.

  16. A real-time laser feedback control method for the three-wave laser source used in the polarimeter-interferometer diagnostic on Joint-TEXT tokamak

    SciTech Connect

    Xiong, C. Y.; Chen, J. Li, Q.; Liu, Y.; Gao, L.

    2014-12-15

    A three-wave laser polarimeter-interferometer, equipped with three independent far-infrared laser sources, has been developed on Joint-TEXT (J-TEXT) tokamak. The diagnostic system is capable of high-resolution temporal and phase measurement of the Faraday angle and line-integrated density. However, for long-term operation (>10 min), the free-running lasers can lead to large drifts of the intermediate frequencies (∼100–∼500 kHz/10 min) and decay of laser power (∼10%–∼20%/10 min), which act to degrade diagnostic performance. In addition, these effects lead to increased maintenance cost and limit measurement applicability to long pulse/steady state experiments. To solve this problem, a real-time feedback control method of the laser source is proposed. By accurately controlling the length of each laser cavity, both the intermediate frequencies and laser power can be simultaneously controlled: the intermediate frequencies are controlled according to the pre-set values, while the laser powers are maintained at an optimal level. Based on this approach, a real-time feedback control system has been developed and applied on J-TEXT polarimeter-interferometer. Long-term (theoretically no time limit) feedback of intermediate frequencies (maximum change less than ±12 kHz) and laser powers (maximum relative power change less than ±7%) has been successfully achieved.

  17. From Research to Operations: Integrating Components of an Advanced Diagnostic System with an Aspect-Oriented Framework

    NASA Technical Reports Server (NTRS)

    Fletcher, Daryl P.; Alena, Richard L.; Akkawi, Faisal; Duncavage, Daniel P.

    2004-01-01

    This paper presents some of the challenges associated with bringing software projects from the research world into an operationa1 environment. While the core functional components of research-oriented software applications can have great utility in an operational setting, these applications often lack aspects important in an operational environment such as logging and security. Furthermore, these stand-alone applications, sometimes developed in isolation from one another, can produce data products useful to other applications in a software ecosystem.

  18. [SIMULTANT OPERATIONS FOR BILIARY CALCULOUS DISEASE AS A METHOD OF PREVENTION OF POSTCHOLECYSTECTOMY SYNDROME].

    PubMed

    Nychytaylo, M Yu; Zagriychuk, M S; Gutsulyak, A I; Goman, A V; Kolesnyk, A V; Stokolos, A V; Prysyazhnyuk, V V

    2015-12-01

    Abstract Own experience of treatment of patients for biliary calculous disease, coexistent with other abdominal and retroperitoneal organs diseases, was analyzed. The rate of postcholecystectomy syndrome (PCHES) occurrence in such patients was determined, the impact of simultant operative interventions using laparoscopic and laparotomic accesses on the rate of the PCHES occurrence was established. The elaborated diagnostic-treatment algorithm with application of measures, directed on the PCHES prophylaxis, was elaborated. There was established, that performance of simultant operations in accordance to strict indications secures a trustworthy reduction of the PCHES occurrence rate.

  19. Flight Dynamics Operations: Methods and Lessons Learned from Space Shuttle Orbit Operations

    NASA Technical Reports Server (NTRS)

    Cutri-Kohart, Rebecca M.

    2011-01-01

    The Flight Dynamics Officer is responsible for trajectory maintenance of the Space Shuttle. This paper will cover high level operational considerations, methodology, procedures, and lessons learned involved in performing the functions of orbit and rendezvous Flight Dynamics Officer and leading the team of flight dynamics specialists during different phases of flight. The primary functions that will be address are: onboard state vector maintenance, ground ephemeris maintenance, calculation of ground and spacecraft acquisitions, collision avoidance, burn targeting for the primary mission, rendezvous, deorbit and contingencies, separation sequences, emergency deorbit preparation, mass properties coordination, payload deployment planning, coordination with the International Space Station, and coordination with worldwide trajectory customers. Each of these tasks require the Flight Dynamics Officer to have cognizance of the current trajectory state as well as the impact of future events on the trajectory plan in order to properly analyze and react to real-time changes. Additionally, considerations are made to prepare flexible alternative trajectory plans in the case timeline changes or a systems failure impact the primary plan. The evolution of the methodology, procedures, and techniques used by the Flight Dynamics Officer to perform these tasks will be discussed. Particular attention will be given to how specific Space Shuttle mission and training simulation experiences, particularly off-nominal or unexpected events such as shortened mission durations, tank failures, contingency deorbit, navigation errors, conjunctions, and unexpected payload deployments, have influenced the operational procedures and training for performing Space Shuttle flight dynamics operations over the history of the program. These lessons learned can then be extended to future vehicle trajectory operations.

  20. Automatic transmission control system and method of operation

    SciTech Connect

    Lemon, R.W.; Arzoian, J.

    1991-04-16

    This patent describes a control system for an automatic transmission of a vehicle with a fluid torque converter having a bypass clutch, and a change gear assembly providing a variety of ratio changes on selective actuation of a plurality of friction engaging elements of the change gear assembly. The control system provides the selective engagement of three friction elements and the bypass clutch through the selective energization and de-energization of two solenoid operated valves and the selective actuation and de-actuation of three shift control valves.

  1. A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator

    SciTech Connect

    Preynas, M.; Laqua, H. P.; Marsen, S.; Reintrog, A.; Corre, Y.; Moncada, V.; Travere, J.-M.

    2015-11-15

    The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

  2. A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator.

    PubMed

    Preynas, M; Laqua, H P; Marsen, S; Reintrog, A; Corre, Y; Moncada, V; Travere, J-M

    2015-11-01

    The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

  3. A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator

    NASA Astrophysics Data System (ADS)

    Preynas, M.; Laqua, H. P.; Marsen, S.; Reintrog, A.; Corre, Y.; Moncada, V.; Travere, J.-M.

    2015-11-01

    The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

  4. Medical diagnosis aboard submarines. Use of a computer-based Bayesian method of analysis in an abdominal pain diagnostic program.

    PubMed

    Osborne, S F

    1984-02-01

    The medical issues that arise in the isolated environment of a submarine can occasionally be grave. While crewmembers are carefully screened for health problems, they are still susceptible to serious acute illness. Currently, the submarine medical department representative, the hospital corpsman, utilizes a history and physical examination, clinical acumen, and limited laboratory testing in diagnosis. The application of a Bayesian method of analysis to an abdominal pain diagnostic system utilizing an onboard microcomputer is described herein. Early results from sea trials show an appropriate diagnosis in eight of 10 cases of abdominal pain, but the program should still be viewed as an extended "laboratory test" until proved effective at sea.

  5. A method for assessing the risks of pipeline operations

    SciTech Connect

    Gloven, M.P.

    1996-09-01

    This paper presents a method for assessing the risks of hazardous liquid and natural gas pipeline systems. The method assesses risk by measuring historical and projected performance data against selected benchmarks, which if exceeded, may indicate that the pipeline may have a greater potential for failure or adverse consequence at certain points. Once these areas are determined, plans are developed and implemented to minimize risk.

  6. Method and apparatus for monitoring plasma processing operations

    DOEpatents

    Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise

    2001-01-01

    The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.

  7. Method and apparatus for monitoring plasma processing operations

    DOEpatents

    Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise

    2002-07-16

    The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.

  8. Method and apparatus for monitoring plasma processing operations

    DOEpatents

    Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise

    2000-01-01

    The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.

  9. Method and apparatus for monitoring plasma processing operations

    DOEpatents

    Smith, Jr., Michael Lane; Stevenson, Joel O'Don; Ward, Pamela Peardon Denise

    2001-01-01

    The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discemible portion thereof (e.g., a plasma step of a multiple step plasma recipe). A final aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system.

  10. STEAM FORMING NEUTRONIC REACTOR AND METHOD OF OPERATING IT

    DOEpatents

    Untermyer, S.

    1960-05-10

    The heterogeneous reactor is liquid moderated and cooled by a steam forming coolant and is designed to produce steam from the coolant directly within the active portion of the reactor while avoiding the formation of bubbles in the liquid moderator. This reactor achieves inherent stability as a result of increased neutron leakage and increased neutron resonance absorption in the U/sup 238/ fuel with the formation of bubbles. The invention produces certain conditions under which the formation of vapor bubbles as a result of a neutron flux excursion from the injection of a reactivity increment into the reactor will operate to nullify the reactivity increment within a sufficiently short period of time to prevent unsafe reactor operating conditions from developing. This is obtained by disposing a plurality of fuel elements within a mass of steam forming coolant in the core with the ratio of the volume of steam forming coolant to the volume of fissionable isotopes being within the range yielding a multiplication factor greater than unity and a negative reactivity to core void coefficient at the boiling temperature of the coolant.

  11. Review of pathogenesis and diagnostic methods of immediate relevance for epidemiology and control of Salmonella Dublin in cattle.

    PubMed

    Nielsen, Liza Rosenbaum

    2013-02-22

    Salmonella enterica subsp. enterica serovar Dublin (S. Dublin) receives increasing attention in cattle production. It is host-adapted to cattle, and leads to unacceptable levels of morbidity, mortality and production losses in both newly and persistently infected herds. Cattle health promoting institutions in several countries are currently constructing active surveillance programmes or voluntary certification programmes, and encourage control and eradication of S. Dublin infected cattle herds. There is a need to understand the underlying pathogenesis of the infection at both animal and herd level to design successful programmes. Furthermore, knowledge about and access to diagnostic tests for use in practice including information about test accuracy and interpretation of available diagnostic test methods are requested. The aim is to synthesise the abundant literature on elements of pathogenesis and diagnosis of immediate relevance for epidemiology and control of S. Dublin at animal and herd level. Relatively few in vivo studies on S. Dublin pathogenesis in cattle included more than a few animals and often showed varying result. It makes it difficult to draw conclusions about mechanisms that affect dissemination in cattle and that might be targets for control methods directed towards improving resistance against the bacteria, e.g. new vaccines. It is recommended to perform larger studies to elucidate dose-response relationships and age- and genetic effects of immunity. Furthermore, it is recommended to attempt to develop faster and more sensitive methods for detection of S. Dublin for diagnosis of infectious animals.

  12. Method and apparatus for monitoring plasma processing operations

    DOEpatents

    Smith, Jr., Michael Lane; Ward, Pamela Denise Peardon; Stevenson, Joel O'Don

    2002-01-01

    The invention generally relates to various aspects of a plasma process, and more specifically the monitoring of such plasma processes. One aspect relates in at least some manner to calibrating or initializing a plasma monitoring assembly. This type of calibration may be used to address wavelength shifts, intensity shifts, or both associated with optical emissions data obtained on a plasma process. A calibration light may be directed at a window through which optical emissions data is being obtained to determine the effect, if any, that the inner surface of the window is having on the optical emissions data being obtained therethrough, the operation of the optical emissions data gathering device, or both. Another aspect relates in at least some manner to various types of evaluations which may be undertaken of a plasma process which was run, and more typically one which is currently being run, within the processing chamber. Plasma health evaluations and process identification through optical emissions analysis are included in this aspect. Yet another aspect associated with the present invention relates in at least some manner to the endpoint of a plasma process (e.g., plasma recipe, plasma clean, conditioning wafer operation) or discrete/discernible portion thereof (e.g., a plasma step of a multiple step plasma recipe). Another aspect associated with the present invention relates to how one or more of the above-noted aspects may be implemented into a semiconductor fabrication facility, such as the distribution of wafers to a wafer production system. A final aspect of the present invention relates to a network a plurality of plasma monitoring systems, including with remote capabilities (i.e., outside of the clean room).

  13. Methods for operating parallel computing systems employing sequenced communications

    DOEpatents

    Benner, R.E.; Gustafson, J.L.; Montry, G.R.

    1999-08-10

    A parallel computing system and method are disclosed having improved performance where a program is concurrently run on a plurality of nodes for reducing total processing time, each node having a processor, a memory, and a predetermined number of communication channels connected to the node and independently connected directly to other nodes. The present invention improves performance of the parallel computing system by providing a system which can provide efficient communication between the processors and between the system and input and output devices. A method is also disclosed which can locate defective nodes with the computing system. 15 figs.

  14. Methods for operating parallel computing systems employing sequenced communications

    DOEpatents

    Benner, Robert E.; Gustafson, John L.; Montry, Gary R.

    1999-01-01

    A parallel computing system and method having improved performance where a program is concurrently run on a plurality of nodes for reducing total processing time, each node having a processor, a memory, and a predetermined number of communication channels connected to the node and independently connected directly to other nodes. The present invention improves performance of performance of the parallel computing system by providing a system which can provide efficient communication between the processors and between the system and input and output devices. A method is also disclosed which can locate defective nodes with the computing system.

  15. Design and Operation of an Optically-Accessible Modular Reactor for Diagnostics of Thermal Thin Film Deposition Processes.

    PubMed

    Kimes, W A; Sperling, B A; Maslars, J E

    2015-01-01

    The design and operation of a simple, optically-accessible modular reactor for probing thermal thin film deposition processes, such as atomic layer deposition processes (ALD) and chemical vapor deposition (CVD), is described. This reactor has a nominal footprint of 225 cm(2) and a mass of approximately 6.6 kg, making it small enough to conveniently function as a modular component of an optical train. The design is simple, making fabrication straightforward and relatively inexpensive. Reactor operation is characterized using two infrared absorption measurements to determine exhaust times for tetrakis(dimethylamino)titanium and water, proto-typical ALD precursors, in a pressure and flow regime commonly used for ALD.

  16. Development of monitoring and diagnostic methods for robots used in remediation of waste sites. 1997 annual progress report

    SciTech Connect

    Tecza, J.

    1998-06-01

    'Safe and efficient clean up of hazardous and radioactive waste sites throughout the DOE complex will require extensive use of robots. This research effort focuses on developing Monitoring and Diagnostic (M and D) methods for robots that will provide early detection, isolation, and tracking of impending faults before they result in serious failure. The utility and effectiveness of applying M and D methods to hydraulic robots has never been proven. The present research program is utilizing seeded faults in a laboratory test rig that is representative of an existing hydraulically-powered remediation robot. This report summarizes activity conducted in the first 9 months of the project. The research team has analyzed the Rosie Mobile Worksystem as a representative hydraulic robot, developed a test rig for implanted fault testing, developed a test plan and agenda, and established methods for acquiring and analyzing the test data.'

  17. Sensitivity and diagnosticity of NASA-TLX and simplified SWAT to assess the mental workload associated with operating an agricultural sprayer.

    PubMed

    Dey, Asit; Mann, Danny D

    2010-07-01

    The objectives of the present study were: a) to investigate three continuous variants of the NASA-Task Load Index (TLX) (standard NASA (CNASA), average NASA (C1NASA) and principal component NASA (PCNASA)) and five different variants of the simplified subjective workload assessment technique (SSWAT) (continuous standard SSWAT (CSSWAT), continuous average SSWAT (C1SSWAT), continuous principal component SSWAT (PCSSWAT), discrete event-based SSWAT (D1SSWAT) and discrete standard SSWAT (DSSWAT)) in terms of their sensitivity and diagnosticity to assess the mental workload associated with agricultural spraying; b) to compare and select the best variants of NASA-TLX and SSWAT for future mental workload research in the agricultural domain. A total of 16 male university students (mean 30.4 +/- 12.5 years) participated in this study. All the participants were trained to drive an agricultural spraying simulator. Sensitivity was assessed by the ability of the scales to report the maximum change in workload ratings due to the change in illumination and difficulty levels. In addition, the factor loading method was used to quantify sensitivity. The diagnosticity was assessed by the ability of the scale to diagnose the change in task levels from single to dual. Among all the variants of NASA-TLX and SSWAT, PCNASA and discrete variants of SSWAT showed the highest sensitivity and diagnosticity. Moreover, among all the variants of NASA and SSWAT, the discrete variants of SSWAT showed the highest sensitivity and diagnosticity but also high between-subject variability. The continuous variants of both scales had relatively low sensitivity and diagnosticity and also low between-subject variability. Hence, when selecting a scale for future mental workload research in the agricultural domain, a researcher should decide what to compromise: 1) between-subject variability or 2) sensitivity and diagnosticity. STATEMENT OF RELEVANCE: The use of subjective workload scales is very popular in

  18. Analysis of Preconditioning and Relaxation Operators for the Discontinuous Galerkin Method Applied to Diffusion

    NASA Technical Reports Server (NTRS)

    Atkins, H. L.; Shu, Chi-Wang

    2001-01-01

    The explicit stability constraint of the discontinuous Galerkin method applied to the diffusion operator decreases dramatically as the order of the method is increased. Block Jacobi and block Gauss-Seidel preconditioner operators are examined for their effectiveness at accelerating convergence. A Fourier analysis for methods of order 2 through 6 reveals that both preconditioner operators bound the eigenvalues of the discrete spatial operator. Additionally, in one dimension, the eigenvalues are grouped into two or three regions that are invariant with order of the method. Local relaxation methods are constructed that rapidly damp high frequencies for arbitrarily large time step.

  19. Design and operation of the pellet charge exchange diagnostic for measurement of energetic confined alphas and tritons on TFTR

    SciTech Connect

    Medley, S.S.; Duong, H.H.; Fisher, R.K.

    1996-05-01

    Radially-resolved energy and density distributions of the energetic confined alpha particles in D-T experiments on TFTR are being measured by active neutral particle analysis using low-Z impurity pellet injection. When injected into a high temperature plasma, an impurity pellet (e.g. Lithium or Boron) rapidly ablates forming an elongated cloud which is aligned with the magnetic field and moves with the pellet. This ablation cloud provides a dense target with which the alpha particles produced in D-T fusion reactions can charge exchange. A small fraction of the alpha particles incident on the pellet ablation cloud will be converted to helium neutrals whose energy is essentially unchanged by the charge transfer process. By measuring the resultant helium neutrals escaping from the plasma using a mass and energy resolving charge exchange analyzer, this technique offers a direct measurement of the energy distribution of the incident high-energy alpha particles. Other energetic ion species can be detected as well, such as tritons generated in D-D plasmas and H or He{sup 3} RF-driven minority ion tails. The diagnostic technique and its application on TFTR are described in detail.

  20. Molecular method for the detection of Andes hantavirus infection: validation for clinical diagnostics.

    PubMed

    Vial, Cecilia; Martinez-Valdebenito, Constanza; Rios, Susana; Martinez, Jessica; Vial, Pablo A; Ferres, Marcela; Rivera, Juan C; Perez, Ruth; Valdivieso, Francisca

    2016-01-01

    Hantavirus cardiopulmonary syndrome is a severe disease caused by exposure to New World hantaviruses. Early diagnosis is difficult due to the lack of specific initial symptoms. Antihantavirus antibodies are usually negative until late in the febrile prodrome or the beginning of cardiopulmonary phase, while Andes hantavirus (ANDV) RNA genome can be detected before symptoms onset. We analyzed the effectiveness of quantitative reverse transcription polymerase chain reaction (RT-qPCR) as a diagnostic tool detecting ANDV-Sout genome in peripheral blood cells from 78 confirmed hantavirus patients and 166 negative controls. Our results indicate that RT-qPCR had a low detection limit (~10 copies), with a specificity of 100% and a sensitivity of 94.9%. This suggests the potential for establishing RT-qPCR as the assay of choice for early diagnosis, promoting early effective care of patients, and improving other important aspects of ANDV infection management, such as compliance of biosafety recommendations for health personnel in order to avoid nosocomial transmission.

  1. Advanced hybrid particulate collector and method of operation

    SciTech Connect

    Miller, Stanley J.

    2003-04-08

    A device and method for controlling particulate air pollutants of the present invention combines filtration and electrostatic collection devices. The invention includes a chamber housing a plurality of rows of filter elements. Between the rows of filter elements are rows of high voltage discharge electrodes. Between the rows of discharge electrodes and the rows of filter elements are grounded perforated plates for creating electrostatic precipitation zones.

  2. Photoacoustic sample vessel and method of elevated pressure operation

    DOEpatents

    Autrey, Tom; Yonker, Clement R.

    2004-05-04

    An improved photoacoustic vessel and method of photoacoustic analysis. The photoacoustic sample vessel comprises an acoustic detector, an acoustic couplant, and an acoustic coupler having a chamber for holding the acoustic couplant and a sample. The acoustic couplant is selected from the group consisting of liquid, solid, and combinations thereof. Passing electromagnetic energy through the sample generates an acoustic signal within the sample, whereby the acoustic signal propagates through the sample to and through the acoustic couplant to the acoustic detector.

  3. Feynman method for disentangling operators and a singular oscillator

    SciTech Connect

    Popov, V. S.; Trusov, M. A.

    2012-02-15

    The problem of the evolution of a singular quantum oscillator with a frequency exhibiting an arbitrary time dependence has been solved. The probabilities w{sub mn} of transitions in the oscillator spectrum and generating functions have been calculated, and the sum rules for w{sub mn} have been derived. The calculations are based on the Feynman disentangling method and the theory of representations of the SU(1, 1) group.

  4. Cellphone camera imaging of a periodically patterned chip as a potential method for point-of-care diagnostics.

    PubMed

    Gupta, Ritu; Reifenberger, Ronald G; Kulkarni, Giridhar U

    2014-03-26

    In this study, we demonstrate that a disposable chip periodically patterned with suitable ligands, an ordinary cellphone camera, and a simple pattern recognition software, can potentially be used for quantitative diagnostics. A key factor in this demonstration is the design of a calibration grid around the chip that, through a contrast transfer process, enables reliable analysis of the images collected under variable ambient lighting conditions. After exposure to a dispersion of amine terminated silica beads used as analyte mimicking pathogens, an epoxy-terminated glass substrate microcontact printed with octadecyltrichlorosilane (250 μm periodicity) developed a characteristic pattern of beads which could be easily imaged with a cellphone camera of 3.2 MP pixels. A simple pattern recognition algorithm using fast Fourier transform produced a quantitative estimate of the analyte concentration present in the test solution. In this method importantly, neither the chip fabrication process nor the fill-factor of the periodic pattern need be perfect to arrive at a conclusive diagnosis. The method suggests a viable platform that may potentially find use in fault-tolerant and robust point-of-care diagnostic applications.

  5. METHOD OF OPERATING A HEAVY WATER MODERATED REACTOR

    DOEpatents

    Vernon, H.C.

    1962-08-14

    A method of removing fission products from the heavy water used in a slurry type nuclear reactor is described. According to the process the slurry is steam distilled with carbon tetrachloride so that at least a part of the heavy water and carbon tetrachloride are vaporized; the heavy water and carbon tetrachloride are separated; the carbon tetrachloride is returned to the steam distillation column at different points in the column to aid in depositing the slurry particles at the bottom of the column; and the heavy water portion of the condensate is purified. (AEC)

  6. Advanced hybrid particulate collector and method of operation

    DOEpatents

    Miller, S.J.

    1999-08-17

    A device and method for controlling particulate air pollutants of the present invention combines filtration and electrostatic collection devices. The invention includes a chamber housing a plurality of rows of filter elements. Between each row of filter elements is a grounded plate. Between the grounded plates and the filter elements are electrode grids for creating electrostatic precipitation zones between each row of filter elements. In this way, when the filter elements are cleaned by pulsing air in a reverse direction, the dust removed from the bags will collect in the electrostatic precipitation zones rather than on adjacent filter elements. 12 figs.

  7. Advanced hybrid particulate collector and method of operation

    DOEpatents

    Miller, Stanley J.

    1999-01-01

    A device and method for controlling particulate air pollutants of the present invention combines filtration and electrostatic collection devices. The invention includes a chamber housing a plurality of rows of filter elements. Between each row of filter elements is a grounded plate. Between the grounded plates and the filter elements are electrode grids for creating electrostatic precipitation zones between each row of filter elements. In this way, when the filter elements are cleaned by pulsing air in a reverse direction, the dust removed from the bags will collect in the electrostatic precipitation zones rather than on adjacent filter elements.

  8. Method of controlling scale in oil recovery operations

    DOEpatents

    Krajicek, Richard W.

    1981-01-01

    Disclosed is a method of producing highly viscous minerals from a subterranean formation by injection of an acidic, thermal vapor stream without substantial scale buildup in downstream piping, pumps and well bore. The process comprises heating the formation by injection of heat, preferably in the form of a thermal vapor stream composed of combustion gases and steam and injecting an acidic compound simultaneously with the thermal vapor stream into the formation at a temperature above the dew point of the thermal vapor stream. The acidic, thermal vapor stream increases the solubility of metal ions in connate water and thus reduces scaling in the downstream equipment during the production of viscous hydrocarbons.

  9. Design and Operation of an Optically-Accessible Modular Reactor for Diagnostics of Thermal Thin Film Deposition Processes

    PubMed Central

    Kimes, W. A.; Sperling, B. A.; Maslars, J. E.

    2015-01-01

    The design and operation of a simple, optically-accessible modular reactor for probing thermal thin film deposition processes, such as atomic layer deposition processes (ALD) and chemical vapor deposition (CVD), is described. This reactor has a nominal footprint of 225 cm2 and a mass of approximately 6.6 kg, making it small enough to conveniently function as a modular component of an optical train. The design is simple, making fabrication straightforward and relatively inexpensive. Reactor operation is characterized using two infrared absorption measurements to determine exhaust times for tetrakis(dimethylamino)titanium and water, proto-typical ALD precursors, in a pressure and flow regime commonly used for ALD. PMID:26958438

  10. Artificial intelligence methods in deregulated power systems operations

    NASA Astrophysics Data System (ADS)

    Ilic, Jovan

    With the introduction of the power systems deregulation, many classical power transmission and distribution optimization tools became inadequate. Optimal Power Flow and Unit Commitment are common computer programs used in the regulated power industry. This work is addressing the Optimal Power Flow and Unit Commitment in the new deregulated environment. Optimal Power Flow is a high dimensional, non-linear, and non-convex optimization problem. As such, it is even now, after forty years since its introduction, a research topic without a widely accepted solution able to encompass all areas of interest. Unit Commitment is a high dimensional, combinatorial problem which should ideally include the Optimal Power Flow in its solution. The dimensionality of a typical Unit Commitment problem is so great that even the enumeration of all the combinations would take too much time for any practical purposes. This dissertation attacks the Optimal Power Flow problem using non-traditional tools from the Artificial Intelligence arena. Artificial Intelligence optimization methods are based on stochastic principles. Usually, stochastic optimization methods are successful where all other classical approaches fail. We will use Genetic Programming optimization for both Optimal Power Flow and Unit Commitment. Long processing times will also be addressed through supervised machine learning.

  11. Operation of the TFTR Pellet Charge Exchange Diagnostic in the Pulse Counting Mode during H+ RF-minority Heating

    SciTech Connect

    Medley, S.S., PPPL

    1998-05-01

    The Pellet Charge Exchange technique on TFTR has been used primarily to obtain active charge exchange measurements using a high energy (0.5 - 4.0 MeV) neutral particle analyzer (NPA) in conjunction with impurity pellet injection (Li and B) with the scintillator-photomultiplier detector system operated in the current mode. While passive measurements using pulse counting were also obtained using this instrumentation, operation in this mode was very restrictive with pulse counting rates limited to less than {approximately}10 kHz in the absence of any significant neutron and gamma induced background signal. An upgrade to a specialized pulse counting capability which was developed by the Ioffe Institute was implemented which consisted of CsI(Tl) scintillators having features designed to minimize signals induced by background neutron and gamma rays and 16-channel pulse height analysis electronics on each of the eight NPA energy channels. Passive measurements of RF-driven energetic hydrogen minority ions which served to verify operation of the pulse counting mode are reported. It is shown that in the passive mode the main donors for the neutralization of H+ ions in this energy range are C5+ ions. The measured effective H+ tail temperatures range from 0.15 MeV at an RF power of 2 MW to 0.35 MeV at 6 MW.

  12. Microbial food safety: Potential of DNA extraction methods for use in diagnostic metagenomics.

    PubMed

    Josefsen, Mathilde H; Andersen, Sandra C; Christensen, Julia; Hoorfar, Jeffrey

    2015-07-01

    The efficiency of ten widely applied DNA extraction protocols was evaluated for suitability for diagnostic metagenomics. The protocols were selected based on a thorough literature study. Chicken fecal samples inoculated with about 1×10(3) and 1×10(6) CFU/g Campylobacter jejuni were used as a model. The evaluation was performed based on total DNA yield measured by fluorometry, and quality and quantity of C. jejuni DNA measured by real-time PCR. There was up to a 25-fold variance between the lowest (NucliSens miniMAG, BIOMÉRIEUX) and highest (PowerLyzer PowerSoil DNA Isolation Kit, MO BIO Laboratories) yielding protocols. The PowerLyzer PowerSoil DNA Isolation Kit performed significantly better than all other protocols tested. Selected protocols were modified, i.e., extended heating and homogenization, resulting in increased yields of total DNA. For QIAamp Fast DNA Stool Mini Kit (Qiagen) a 7-fold increase in total DNA was observed following the protocol for human DNA analysis and including a 5 min heating step at 70°C. For the PowerLyzer PowerSoil and the PowerFecal DNA Isolation Kit (MO BIO Laboratories) the total DNA fold increase was 1.6 to 1.8 when including an extra 10 min of bead-vortexing. There was no correlation between the yield of total DNA and the amount of PCR-amplifiable DNA from C. jejuni. The protocols resulting in the highest yield of total DNA did not show correspondingly increased levels of C. jejuni DNA as determined by PCR. In conclusion, substantial variation in the efficiency of the protocols to extract DNA was observed. The highest DNA yield was obtained with the PowerLyzer PowerSoil DNA Isolation Kit, whereas the FastDNA SPIN Kit for Feces (MP Biomedicals) resulted in the highest amount of PCR-amplifiable C. jejuni DNA. PMID:25937085

  13. Rapid diagnostic method for the identification of Mycoplasma pneumoniae respiratory tract infection.

    PubMed

    Miyashita, Naoyuki; Kawai, Yasuhiro; Kato, Tadashi; Tanaka, Takaaki; Akaike, Hiroto; Teranishi, Hideto; Nakano, Takashi; Ouchi, Kazunobu; Okimoto, Niro

    2016-05-01

    Rapid diagnostic tests are useful tools in the early diagnosis of respiratory tract infections (RTIs) caused by a specific pathogens. We investigated the sensitivity and specificity of a rapid and simple antigen test for the detection of Mycoplasma pneumoniae, Ribotest Mycoplasma(®) in adolescent and adult patients with RTIs. In addition, we evaluated the accuracy of clinical and laboratory findings for the early presumptive diagnosis of M. pneumoniae RTI. We compared 55 cases with laboratory-confirmed M. pneumoniae infection using serology, culture, and polymerase chain reaction (PCR) and 346 cases without laboratory-confirmed M. pneumoniae infection. Pneumonia cases were excluded in this study. Among patients with M. pneumoniae infection, the incidences of cough, sore throat, and sputum production were high, with rates of 98%, 61%, and 67%, respectively, but the specificity was low. The prevalence of nasal symptoms was significantly lower in patients with M. pneumoniae infection (9%) than in non-M. pneumoniae infection (70%; p < 0.0001). When PCR was used as the control test, the sensitivity, specificity, and overall agreement rates with Ribotest(®) were 71%, 89%, and 87%, respectively. Clinical symptoms and laboratory data were of limited value in making the diagnosis of M. pneumoniae RTI in adolescent and adult patients. Our results suggested that Ribotest(®) may be helpful in distinguishing M. pneumoniae RTI patients from those without the disease. Physicians should consider the use of Ribotest(®) when patients have a persistent cough without nasal symptoms. PMID:26993174

  14. Microbial food safety: Potential of DNA extraction methods for use in diagnostic metagenomics.

    PubMed

    Josefsen, Mathilde H; Andersen, Sandra C; Christensen, Julia; Hoorfar, Jeffrey

    2015-07-01

    The efficiency of ten widely applied DNA extraction protocols was evaluated for suitability for diagnostic metagenomics. The protocols were selected based on a thorough literature study. Chicken fecal samples inoculated with about 1×10(3) and 1×10(6) CFU/g Campylobacter jejuni were used as a model. The evaluation was performed based on total DNA yield measured by fluorometry, and quality and quantity of C. jejuni DNA measured by real-time PCR. There was up to a 25-fold variance between the lowest (NucliSens miniMAG, BIOMÉRIEUX) and highest (PowerLyzer PowerSoil DNA Isolation Kit, MO BIO Laboratories) yielding protocols. The PowerLyzer PowerSoil DNA Isolation Kit performed significantly better than all other protocols tested. Selected protocols were modified, i.e., extended heating and homogenization, resulting in increased yields of total DNA. For QIAamp Fast DNA Stool Mini Kit (Qiagen) a 7-fold increase in total DNA was observed following the protocol for human DNA analysis and including a 5 min heating step at 70°C. For the PowerLyzer PowerSoil and the PowerFecal DNA Isolation Kit (MO BIO Laboratories) the total DNA fold increase was 1.6 to 1.8 when including an extra 10 min of bead-vortexing. There was no correlation between the yield of total DNA and the amount of PCR-amplifiable DNA from C. jejuni. The protocols resulting in the highest yield of total DNA did not show correspondingly increased levels of C. jejuni DNA as determined by PCR. In conclusion, substantial variation in the efficiency of the protocols to extract DNA was observed. The highest DNA yield was obtained with the PowerLyzer PowerSoil DNA Isolation Kit, whereas the FastDNA SPIN Kit for Feces (MP Biomedicals) resulted in the highest amount of PCR-amplifiable C. jejuni DNA.

  15. Diagnostic Criteria for Problematic Internet Use among U.S. University Students: A Mixed-Methods Evaluation.

    PubMed

    Li, Wen; O'Brien, Jennifer E; Snyder, Susan M; Howard, Matthew O

    2016-01-01

    Empirical studies have identified increasing rates of problematic Internet use worldwide and a host of related negative consequences. However, researchers disagree as to whether problematic Internet use is a subtype of behavioral addiction. Thus, there are not yet widely accepted and validated diagnostic criteria for problematic Internet use. To address this gap, we used mixed-methods to examine the extent to which signs and symptoms of problematic Internet use mirror DSM-5 diagnostic criteria for substance use disorder, gambling disorder, and Internet gaming disorder. A total of 27 university students, who self-identified as intensive Internet users and who reported Internet-use-associated health and/or psychosocial problems were recruited. Students completed two measures that assess problematic Internet use (Young's Diagnostic Questionnaire and the Compulsive Internet Use Scale) and participated in focus groups exploring their experiences with problematic Internet use. Results of standardized measures and focus group discussions indicated substantial overlap between students' experiences of problematic Internet use and the signs and symptoms reflected in the DSM-5 criteria for substance use disorder, gambling disorder, and Internet gaming disorder. These signs and symptoms included: a) use Internet longer than intended, b) preoccupation with the Internet, c) withdrawal symptoms when unable to access the Internet, d) unsuccessful attempts to stop or reduce Internet use, e) craving, f) loss of interest in hobbies or activities other than the Internet, g) excessive Internet use despite the knowledge of related problems, g) use of the Internet to escape or relieve a negative mood, and h) lying about Internet use. Tolerance, withdrawal symptoms, and recurrent Internet use in hazardous situations were uniquely manifested in the context of problematic Internet use. Implications for research and practice are discussed.

  16. Diagnostic Criteria for Problematic Internet Use among U.S. University Students: A Mixed-Methods Evaluation

    PubMed Central

    Li, Wen; O’Brien, Jennifer E.; Snyder, Susan M.; Howard, Matthew O.

    2016-01-01

    Empirical studies have identified increasing rates of problematic Internet use worldwide and a host of related negative consequences. However, researchers disagree as to whether problematic Internet use is a subtype of behavioral addiction. Thus, there are not yet widely accepted and validated diagnostic criteria for problematic Internet use. To address this gap, we used mixed-methods to examine the extent to which signs and symptoms of problematic Internet use mirror DSM-5 diagnostic criteria for substance use disorder, gambling disorder, and Internet gaming disorder. A total of 27 university students, who self-identified as intensive Internet users and who reported Internet-use-associated health and/or psychosocial problems were recruited. Students completed two measures that assess problematic Internet use (Young’s Diagnostic Questionnaire and the Compulsive Internet Use Scale) and participated in focus groups exploring their experiences with problematic Internet use. Results of standardized measures and focus group discussions indicated substantial overlap between students’ experiences of problematic Internet use and the signs and symptoms reflected in the DSM-5 criteria for substance use disorder, gambling disorder, and Internet gaming disorder. These signs and symptoms included: a) use Internet longer than intended, b) preoccupation with the Internet, c) withdrawal symptoms when unable to access the Internet, d) unsuccessful attempts to stop or reduce Internet use, e) craving, f) loss of interest in hobbies or activities other than the Internet, g) excessive Internet use despite the knowledge of related problems, g) use of the Internet to escape or relieve a negative mood, and h) lying about Internet use. Tolerance, withdrawal symptoms, and recurrent Internet use in hazardous situations were uniquely manifested in the context of problematic Internet use. Implications for research and practice are discussed. PMID:26751569

  17. Methods Developed by the Tools for Engine Diagnostics Task to Monitor and Predict Rotor Damage in Real Time

    NASA Technical Reports Server (NTRS)

    Baaklini, George Y.; Smith, Kevin; Raulerson, David; Gyekenyesi, Andrew L.; Sawicki, Jerzy T.; Brasche, Lisa

    2003-01-01

    Tools for Engine Diagnostics is a major task in the Propulsion System Health Management area of the Single Aircraft Accident Prevention project under NASA s Aviation Safety Program. The major goal of the Aviation Safety Program is to reduce fatal aircraft accidents by 80 percent within 10 years and by 90 percent within 25 years. The goal of the Propulsion System Health Management area is to eliminate propulsion system malfunctions as a primary or contributing factor to the cause of aircraft accidents. The purpose of Tools for Engine Diagnostics, a 2-yr-old task, is to establish and improve tools for engine diagnostics and prognostics that measure the deformation and damage of rotating engine components at the ground level and that perform intermittent or continuous monitoring on the engine wing. In this work, nondestructive-evaluation- (NDE-) based technology is combined with model-dependent disk spin experimental simulation systems, like finite element modeling (FEM) and modal norms, to monitor and predict rotor damage in real time. Fracture mechanics time-dependent fatigue crack growth and damage-mechanics-based life estimation are being developed, and their potential use investigated. In addition, wireless eddy current and advanced acoustics are being developed for on-wing and just-in-time NDE engine inspection to provide deeper access and higher sensitivity to extend on-wing capabilities and improve inspection readiness. In the long run, these methods could establish a base for prognostic sensing while an engine is running, without any overt actions, like inspections. This damage-detection strategy includes experimentally acquired vibration-, eddy-current- and capacitance-based displacement measurements and analytically computed FEM-, modal norms-, and conventional rotordynamics-based models of well-defined damages and critical mass imbalances in rotating disks and rotors.

  18. Diagnostic accuracy of existing methods for identifying diabetic foot ulcers from inpatient and outpatient datasets

    PubMed Central

    2010-01-01

    Background As the number of persons with diabetes is projected to double in the next 25 years in the US, an accurate method of identifying diabetic foot ulcers in population-based data sources are ever more important for disease surveillance and public health purposes. The objectives of this study are to evaluate the accuracy of existing methods and to propose a new method. Methods Four existing methods were used to identify all patients diagnosed with a foot ulcer in a Department of Veterans Affairs (VA) hospital from the inpatient and outpatient datasets for 2003. Their electronic medical records were reviewed to verify whether the medical records positively indicate presence of a diabetic foot ulcer in diagnoses, medical assessments, or consults. For each method, five measures of accuracy and agreement were evaluated using data from medical records as the gold standard. Results Our medical record reviews show that all methods had sensitivity > 92% but their specificity varied substantially between 74% and 91%. A method used in Harrington et al. (2004) was the most accurate with 94% sensitivity and 91% specificity and produced an annual prevalence of 3.3% among VA users with diabetes nationwide. A new and simpler method consisting of two codes (707.1× and 707.9) shows an equally good accuracy with 93% sensitivity and 91% specificity and 3.1% prevalence. Conclusions Our results indicate that the Harrington and New methods are highly comparable and accurate. We recommend the Harrington method for its accuracy and the New method for its simplicity and comparable accuracy. PMID:21106076

  19. Evaluation of ride quality prediction methods for operational military helicopters

    NASA Technical Reports Server (NTRS)

    Leatherwood, J. D.; Clevenson, S. A.; Hollenbaugh, D. D.

    1984-01-01

    The results of a simulator study conducted to compare and validate various ride quality prediction methods for use in assessing passenger/crew ride comfort within helicopters are presented. Included are results quantifying 35 helicopter pilots' discomfort responses to helicopter interior noise and vibration typical of routine flights, assessment of various ride quality metrics including the NASA ride comfort model, and examination of possible criteria approaches. Results of the study indicated that crew discomfort results from a complex interaction between vibration and interior noise. Overall measures such as weighted or unweighted root-mean-square acceleration level and A-weighted noise level were not good predictors of discomfort. Accurate prediction required a metric incorporating the interactive effects of both noise and vibration. The best metric for predicting crew comfort to the combined noise and vibration environment was the NASA discomfort index.

  20. Method and apparatus for operating on companded PCM voice data

    NASA Technical Reports Server (NTRS)

    Byrne, F. (Inventor)

    1986-01-01

    The method and apparatus constructed in accordance with this invention permits a plurality of parties to speak to each other on a conference line with a minimum of interference. The apparatus digitizes audio signals. Each of the parties has an audio transmitter and receiver provided for transmitting and receiving audio signals. The audio signals are converted to a PCM companded eight-bit parallel signal followed by a conversion to a serial signal for transmitting to a remote location and then reconverting each of the companded signals to a first-eight-bit parallel signal. The eight-bit parallel signal is fed to one input of a pre-programmed ROM. This eight-bit signal provides one-half of a sixteen-bit address of a lookup ROM. The other half of the sixteen-bit ROM address is supplied by another suscriber over an identical circuit.

  1. Evaluation of three different methods of distance learning for postgraduate diagnostic imaging education: A pilot study.

    PubMed

    Poirier, Jean-Nicolas; Cooley, Jeffrey R; Wessely, Michelle; Guebert, Gary M; Petrocco-Napuli, Kristina

    2014-10-01

    Objective : The purpose of this study was to evaluate the perceived effectiveness and learning potential of 3 Web-based educational methods in a postgraduate radiology setting. Methods : Three chiropractic radiology faculty from diverse geographic locations led mini-courses using asynchronous discussion boards, synchronous Web conferencing, and asynchronous voice-over case presentations formatted for Web viewing. At the conclusion of each course, participants filled out a 14-question survey (using a 5-point Likert scale) designed to evaluate the effectiveness of each method in achieving specified course objectives and goals and their satisfaction when considering the learning potential of each method. The mean, standard deviation, and percentage agreements were tabulated. Results : Twenty, 15, and 10 participants completed the discussion board, Web conferencing, and case presentation surveys, respectively. All educational methods demonstrated a high level of agreement regarding the course objective (total mean rating >4.1). The case presentations had the highest overall rating for achieving the course goals; however, all but one method still had total mean ratings >4.0 and overall agreement levels of 70%-100%. The strongest potential for interactive learning was found with Web conferencing and discussion boards, while case presentations rated very low in this regard. Conclusions : The perceived effectiveness in achieving the course objective and goals was high for each method. Residency-based distance education may be a beneficial adjunct to current methods of training, allowing for international collaboration. When considering all aspects tested, there does not appear to be a clear advantage to any one method. Utilizing various methods may be most appropriate.

  2. Evaluation of three different methods of distance learning for postgraduate diagnostic imaging education: A pilot study

    PubMed Central

    Poirier, Jean-Nicolas; Cooley, Jeffrey R.; Wessely, Michelle; Guebert, Gary M.; Petrocco-Napuli, Kristina

    2014-01-01

    Objective The purpose of this study was to evaluate the perceived effectiveness and learning potential of 3 Web-based educational methods in a postgraduate radiology setting. Methods Three chiropractic radiology faculty from diverse geographic locations led mini-courses using asynchronous discussion boards, synchronous Web conferencing, and asynchronous voice-over case presentations formatted for Web viewing. At the conclusion of each course, participants filled out a 14-question survey (using a 5-point Likert scale) designed to evaluate the effectiveness of each method in achieving specified course objectives and goals and their satisfaction when considering the learning potential of each method. The mean, standard deviation, and percentage agreements were tabulated. Results Twenty, 15, and 10 participants completed the discussion board, Web conferencing, and case presentation surveys, respectively. All educational methods demonstrated a high level of agreement regarding the course objective (total mean rating >4.1). The case presentations had the highest overall rating for achieving the course goals; however, all but one method still had total mean ratings >4.0 and overall agreement levels of 70%–100%. The strongest potential for interactive learning was found with Web conferencing and discussion boards, while case presentations rated very low in this regard. Conclusions The perceived effectiveness in achieving the course objective and goals was high for each method. Residency-based distance education may be a beneficial adjunct to current methods of training, allowing for international collaboration. When considering all aspects tested, there does not appear to be a clear advantage to any one method. Utilizing various methods may be most appropriate. PMID:24779546

  3. Control system for, and a method of, heating an operator station of a work machine

    DOEpatents

    Baker, Thomas M.; Hoff, Brian D.; Akasam, Sivaprasad

    2005-04-05

    There are situations in which an operator remains in an operator station of a work machine when an engine of the work machine is inactive. The present invention includes a control system for, and a method of, heating the operator station when the engine is inactive. A heating system of the work machine includes an electrically-powered coolant pump, a power source, and at least one piece of warmed machinery. An operator heat controller is moveable between a first and a second position, and is operable to connect the electrically-powered coolant pump to the power source when the engine is inactive and the operator heat controller is in the first position. Thus, by deactivating the engine and then moving the operator heat controller to the first position, the operator may supply electrical energy to the electrically-powered coolant pump, which is operably coupled to heat the operator station.

  4. Method and machine for high strength undiffused brushless operation

    DOEpatents

    Hsu, John S.

    2003-06-03

    A brushless electric machine (30) having a stator (31) and a rotor (32) and a main air gap (34), the rotor (32) having pairs of rotor pole portions (22b, 22c, 32f, 32l) disposed at least partly around the axis of rotation (32p) and facing the main air gap (24b, 24c, 34), at least one stationary winding (20b, 20c, 33b) separated from the rotor (22b, 22c, 32) by a secondary air gap (23b, 23c, 35) so as to induce a rotor-side flux in the rotor (22b, 22c, 32) which controls a resultant flux in the main air gap (24b, 24c, 34). PM material (27b, 27c) is disposed in spaces between the rotor pole portions (22b, 22c, 32f, 32l) to inhibit the rotor-side flux from leaking from said pole portions (22b, 22c, 32f, 32l) prior to reaching the main air gap (24b, 24c, 34). By selecting the direction of current in the stationary winding (20b, 20c, 33b) both flux enhancement and flux weakening are provided for the main air gap (24b, 24c, 34). The stationary windings (31a, 33b) which are used for both primary and secondary excitation allow for easier adaptation to cooling systems as described. A method of non-diffused flux enhancement and flux weakening is also disclosed.

  5. WASTE PACKAGE OPERATIONS FY99 CLOSURE METHODS REPORT

    SciTech Connect

    M. C. Knapp

    1999-09-23

    The waste package (WP) closure weld development task is part of a larger engineering development program to develop waste package designs. The purpose of the larger waste package engineering development program is to develop nuclear waste package fabrication and closure methods that the Nuclear Regulatory Commission will find acceptable and will license for disposal of spent nuclear fuel (SNF), non-fuel components, and vitrified high-level waste within a Monitored Geologic Repository (MGR). Within the WP closure development program are several major development tasks, which, in turn, are divided into subtasks. The major tasks include: WP fabrication development, WP closure weld development, nondestructive examination (NDE) development, and remote in-service inspection development. The purpose of this report is to present the objectives, technical information, and work scope relating to the WP closure weld development.and NDE tasks and subtasks and to report results of the closure weld and NDE development programs for fiscal year 1999 (FY-99). The objective of the FY-99 WP closure weld development task was to develop requirements for closure weld surface and volumetric NDE performance demonstrations, investigate alternative NDE inspection techniques, and develop specifications for welding, NDE, and handling system integration. In addition, objectives included fabricating several flat plate mock-ups that could be used for NDE development, stress relief peening, corrosion testing, and residual stress testing.

  6. A comparative study of the diagnostic methods for Group A streptococcal sore throat in two reference hospitals in Yaounde, Cameroon

    PubMed Central

    Gonsu, Hortense Kamga; Bomki, Cynthia Mbimenyuy; Djomou, François; Toukam, Michel; Ndze, Valantine Ngum; Lyonga, Emilia Enjema; Mbakop, Calixte Didier; Koulla-Shiro, Sinata

    2015-01-01

    Introduction Sore throat is a common complaint in general practice which is more frequent in children. The most frequent pathogenic bacteria associated with this infection is Streptococcus pyogenes. Rapid Antigen Diagnostic Test (RADT) facilitates the rapid identification and consequently prompt treatment of patients, prevents complications, and also reduces the risk of spread of Group A Streptococcus (GAS). The main objective of this study was to assess the diagnostic value of a rapid streptococcal antigen detection test in patients with sore throat. Methods A cross-sectional descriptive study was carried out from January to April 2011 on patients aged 3 to 72 years consulting for pharyngitis or sore throat at the paediatric and Ear, Nose and Throat units of the University Teaching Hospital Yaounde and the Central Hospital Yaounde. Two throat swabs were collected per patient. One was used for the rapid test and the other for standard bacteriological analysis. Results The prevalence of GAS in the study population was 22.5%. Out of the 71 samples collected, the RADT detected group A streptococcal antigens in 12 of 16 positive cultures giving a sensitivity of 75%. The specificity of the rapid test was 96%, with positive predictive value of 85.7%, and negative predictive value of 93% respectively. Conclusion Rapid test may have an additional value in the management of patients with high risk of having GAS infection. However, tests with a higher sensitivity are needed for accurate and reliable results for early diagnosis of patients with sore throat caused by GAS. PMID:27386017

  7. Operation of Vehicles in AGV System and Method for Analyzing the Operation

    NASA Astrophysics Data System (ADS)

    Hoshino, Takahiro; Tsuboi, Kazuhiro; Yamanaka, Kazuo; Hamamatsu, Yoshio

    It is important to discuss the behavior of traffic at merging sections for the design and realization of an automated guided vehicle system (AGVS). In this study, we deal with a merging section of the AGVS by considering a time limit for the merging of vehicles. Near the merging section, traffic flowing in one direction must form a queue to avoid collisions between vehicles. We propose an improvement in the control strategy proposed in the previous research. However, it is difficult to analyze the mathematical model of the merging section. Analysis can be performed only for the case in which the time limit is one unit. We also propose a method for analyzing the model for an arbitrary time limit using a linear recurrence relation. We quantitatively discuss the influence of the time limit on the average queue length and the detour rate.

  8. Diagnostic value of CYFRA 21-1 and CEA for predicting lymph node metastasis in operable lung cancer.

    PubMed

    Chen, Feng; Yan, Cui-E; Li, Jia; Han, Xiao-Hong; Wang, Hai; Qi, Jun

    2015-01-01

    Tumour markers are used extensively for the management of lung cancer, including diagnosis, evaluating effectiveness of treatments, monitoring recurrence after therapy and for predicting prognosis. However, there exists a knowledge gap regarding potential quantitative correlations between tumour marker levels and the extents of lymph node involvement in primary lung cancer. The current study is comprised of 139 lung cancer patients scheduled to undergo surgical operation. Of the 139 patients, 107 were subsequently diagnosed with lung cancer without lymph node involvement and 32 were diagnosed with malignant disease with lymph node involvement by histological examination. Preoperative tumour marker levels were quantified in each patient. The median tumour marker levels were statistically higher in lung cancer patients with malignant lymph nodes than in those who suffered either benign lung disease or carcinoma in situ (Kruskal-Wallistest; P = 0.001). Tumour marker levels were significantly correlated with clinical stage (ANOVA; P = 0.009). When examined as a dichotomous variable (CYFRA 21-1 ≤ 5.0 and CEA ≤ 5.0 group and CYFRA 21-1 > 5.0 or CEA > 5.0 group), elevated tumour marker levels correlated strongly with the presence of positive lymph nodes (χ(2) test; P = 0.000). This correlation suggests that the tumour marker levels are clinical predictors for the malignant involvement of lymph nodes in operable lung cancer patients. PMID:26309663

  9. Converting Radiology Operations in a Six-Hospital Healthcare System from Film-Based to Digital: Another Leadership Role for the Diagnostic Medical Physicist

    NASA Astrophysics Data System (ADS)

    Arreola, Manuel M.; Rill, Lynn N.

    2004-09-01

    As medical facilities across the United States continue to convert their radiology operations from film-based to digital environments, partially accomplished and failed endeavors are frequent because of the lack of competent and knowledgeable leadership. The diagnostic medical physicist is, without a doubt, in a privileged position to take such a leadership role, not only because of her/his understanding of the basics principles of new imaging modalities, but also because of her/his inherent participation in workflow design and educational/training activities. A well-structured approach by the physicist will certainly lead the project to a successful completion, opening, in turn, new opportunities for the medical physicist to become an active participant in the decision-making process for an institution.

  10. CONCEPTUAL MODELS AND METHODS TO GUIDE DIAGNOSTIC RESEARCH INTO CAUSES OF IMPAIRMENT TO AQUATIC ECOSYSTEMS

    EPA Science Inventory

    Methods and conceptual models to guide the development of tools for diagnosing the causes of biological impairment within aquatic ecosystems of the United States are described in this report. The conceptual models developed here address nutrients, suspended and bedded sediments (...

  11. Identification of Hog Cholera Viral Antigen by Immunofluorescence. Application as a Diagnostic and Assay Method.

    PubMed

    Mengeling, W L; Pirtle, E C; Torrey, J P

    1963-10-01

    In the absence of detectable cytologic changes in hog cholera virus-infected tissue culture cells, hog cholera viral antigen was readily detected by immunofluorescence. The ability to detect hog cholera viral antigen by this method allowed for determination of infectivity titers and also for titration of homologous antibody. Immunofluorescence made possible the identification, in tissue culture, of hog cholera virus from blood, serum, and spleen extracts of experimentally infected swine. Further applications of this method and its limitations are being investigated.

  12. PERFORMING DIAGNOSTICS ON THE SPALLATION NEUTRON SOURCE VISION BEAM LINE TO ELIMINATE HIGH VIBRATION LEVELS AND PROVIDE A SUSTAINABLE OPERATION

    SciTech Connect

    Van Hoy, Blake W

    2014-01-01

    The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL) provides variable energy neutrons for a variety of experiments. The neutrons proceed down beam lines to the experiment hall, which houses a variety of experiments and test articles. Each beam line has one or more neutron choppers which filter the neutron beam based on the neutron energy by using a rotating neutron absorbing material passing through the neutron beam. Excessive vibration of the Vision beam line, believed to be caused by the T0 chopper, prevented the Vision beam line from operating at full capacity. This problem had been addressed several times by rebalancing/reworking the T0 beam chopper but the problem stubbornly persisted. To determine the cause of the high vibration, dynamic testing was performed. Twenty-seven accelerometer and motor current channels of data were collected during drive up, drive down, coast down, and steady-state conditions; resonance testing and motor current signature analysis were also performed. The data was analyzed for traditional mechanical/machinery issues such as misalignment and imbalance using time series analysis, frequency domain analysis, and operating deflection shape analysis. The analysis showed that the chopper base plate was experiencing an amplified response to the excitation provided by the T0 beam chopper. The amplified response was diagnosed to be caused by higher than expected base plate flexibility, possibly due to improper grouting or loose floor anchors. Based on this diagnosis, a decision was made to dismantle the beam line chopper and remount the base plate. Neutron activation of the beam line components make modifications to the beam line especially expensive and time consuming due to the radiation handling requirements, so this decision had significant financial and schedule implications. It was found that the base plate was indeed loose because of improper grouting during its initial installation. The base plate was

  13. Reduce operating costs through proper fuel specifications, purchasing, and contracting methods

    SciTech Connect

    Weigand, P.

    1995-09-01

    Methods for reducing plant operating costs through proper fuel specifications, purchasing, and contracting are outlined. The following topics are discussed: specifications for fuel oils and propane, purchasing and contracting methods, distribution capability, price flexibility, formula buying and price protection plans.

  14. Diagnostic Methods for Detection of Cotinine Level in Tobacco Users: A Review.

    PubMed

    Raja, Mitali; Garg, Aarti; Yadav, Pramod; Jha, Kunal; Handa, Sahil

    2016-03-01

    The greatest disease-producing product known to man is tobacco. It is a cause of many oral diseases and adverse oral conditions. In India, tobacco is available in smokeless and smoking form. Tobacco contains nicotine which metabolises to form a toxic alkaloid i.e. cotinine. It stimulates autonomic ganglia and central nervous system. Cotinine is the best indicator of tobacco smoke exposure. Various methods are used to measure cotinine level in blood, saliva and urine such as high performance liquid chromatography, colorimetric assay, gas chromatography, NicAlert saliva test, etc. Thus such wide range of methods for cotinine detection in tobacco users requires a detailed discussion regarding their utility. This review will help readers to compare various methods for cotinine detection and enable them to make scientifically informative decision. PMID:27135020

  15. Pattern classification approach to rocket engine diagnostics

    SciTech Connect

    Tulpule, S.

    1989-01-01

    This paper presents a systems level approach to integrate state-of-the-art rocket engine technology with advanced computational techniques to develop an integrated diagnostic system (IDS) for future rocket propulsion systems. The key feature of this IDS is the use of advanced diagnostic algorithms for failure detection as opposed to the current practice of redline-based failure detection methods. The paper presents a top-down analysis of rocket engine diagnostic requirements, rocket engine operation, applicable diagnostic algorithms, and algorithm design techniques, which serve as a basis for the IDS. The concepts of hierarchical, model-based information processing are described, together with the use uf signal processing, pattern recognition, and artificial intelligence techniques which are an integral part of this diagnostic system. 27 refs.

  16. Comparison of the diagnostic accuracy, sensitivity and specificity of four odontological methods for age evaluation in Italian children at the age threshold of 14 years using ROC curves.

    PubMed

    Pinchi, Vilma; Pradella, Francesco; Vitale, Giulia; Rugo, Dario; Nieri, Michele; Norelli, Gian-Aristide

    2016-01-01

    The age threshold of 14 years is relevant in Italy as the minimum age for criminal responsibility. It is of utmost importance to evaluate the diagnostic accuracy of every odontological method for age evaluation considering the sensitivity, or the ability to estimate the true positive cases, and the specificity, or the ability to estimate the true negative cases. The research aims to compare the specificity and sensitivity of four commonly adopted methods of dental age estimation - Demirjian, Haavikko, Willems and Cameriere - in a sample of Italian children aged between 11 and 16 years, with an age threshold of 14 years, using receiver operating characteristic curves and the area under the curve (AUC). In addition, new decision criteria are developed to increase the accuracy of the methods. Among the four odontological methods for age estimation adopted in the research, the Cameriere method showed the highest AUC in both female and male cohorts. The Cameriere method shows a high degree of accuracy at the age threshold of 14 years. To adopt the Cameriere method to estimate the 14-year age threshold more accurately, however, it is suggested - according to the Youden index - that the decision criterion be set at the lower value of 12.928 for females and 13.258 years for males, obtaining a sensitivity of 85% and specificity of 88% in females, and a sensitivity of 77% and specificity of 92% in males. If a specificity level >90% is needed, the cut-off point should be set at 12.959 years (82% sensitivity) for females.

  17. Diagnostic and interventional radiology in the post-operative period and follow-up of patients after rectal resection with coloanal anastomosis.

    PubMed

    Severini, A; Civelli, E M; Uslenghi, E; Cozzi, G; Salvetti, M; Milella, M; Gallino, G; Bonfanti, G; Belli, F; Leo, E

    2000-01-01

    Surgical treatment of carcinoma of the distal third of the rectum with anal sphincter preservation is increasingly used in accredited cancer centers. This study aimed to evaluate the diagnostic usefulness of radiological investigations in the management of patients who had undergone resection with coloanal anastomosis for carcinoma of the rectum, in the immediate post-operative period, during closure of the protective colostomy and in the follow-up of symptomatic recanalized patients. A total of 175 patients who had undergone total rectal resection with end-to-side anastomosis for carcinoma of the distal third of the rectal ampulla, most of whom had received postoperative radiotherapy, were evaluated radiologically. In the postoperative period radiological investigation was ordered only for symptomatic patients to detect pathology of the anastomosis and the pouch sutures and was used direct film abdominal radiography and contrast-enhanced radiography of the rectal stump with a water-soluble radio-opaque agent. Before closure of the colostomy, 2 months after rectal excision or approximately 4 months after if postoperative radiotherapy was given, the anastomosis and pouch of all patients, even asymptomatic ones, were studied with water-soluble contrast enema to check for normal canalization. In the follow-up after recanalization radiological examinations were done to complete the study of the large intestine if the endoscopist was not able to examine it up to the cecum. Of the 175 patients examined radiologically during the postoperative period and/or subsequent follow-up, 95 showed no pathological findings. Seventy-nine patients had fistulas of the coloanal anastomosis or the pouch, 23 of which supplied a presacral collection. In the absence of severe sepsis, the only therapeutic measures were systemic antibiotics and washing of the surgical catheters to maintain efficient operation. In 2 patients in whom transanal drainage was performed radiologically the fistula

  18. Diagnostic methods for and clinical pictures of polyomavirus primary infections in children, Finland.

    PubMed

    Chen, Tingting; Tanner, Laura; Simell, Ville; Hedman, Lea; Mäkinen, Marjaana; Sadeghi, Mohammadreza; Veijola, Riitta; Hyöty, Heikki; Ilonen, Jorma; Knip, Mikael; Toppari, Jorma; Simell, Olli; Söderlund-Venermo, Maria; Hedman, Klaus

    2014-04-01

    We used comprehensive serodiagnostic methods (IgM, IgG, and IgG avidity) and PCR to study Merkel cell polyomavirus and trichodysplasia spinulosa-associated polyomavirus infections in children observed from infancy to adolescence. Comparing seroconversion intervals with previous and subsequent intervals, we found that primary infections with these 2 viruses were asymptomatic in childhood.

  19. New analysis methods to push the boundaries of diagnostic techniques in the environmental sciences

    NASA Astrophysics Data System (ADS)

    Lungaroni, M.; Murari, A.; Peluso, E.; Gelfusa, M.; Malizia, A.; Vega, J.; Talebzadeh, S.; Gaudio, P.

    2016-04-01

    In the last years, new and more sophisticated measurements have been at the basis of the major progress in various disciplines related to the environment, such as remote sensing and thermonuclear fusion. To maximize the effectiveness of the measurements, new data analysis techniques are required. First data processing tasks, such as filtering and fitting, are of primary importance, since they can have a strong influence on the rest of the analysis. Even if Support Vector Regression is a method devised and refined at the end of the 90s, a systematic comparison with more traditional non parametric regression methods has never been reported. In this paper, a series of systematic tests is described, which indicates how SVR is a very competitive method of non-parametric regression that can usefully complement and often outperform more consolidated approaches. The performance of Support Vector Regression as a method of filtering is investigated first, comparing it with the most popular alternative techniques. Then Support Vector Regression is applied to the problem of non-parametric regression to analyse Lidar surveys for the environments measurement of particulate matter due to wildfires. The proposed approach has given very positive results and provides new perspectives to the interpretation of the data.

  20. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    ERIC Educational Resources Information Center

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  1. 49 CFR 192.945 - What methods must an operator use to measure program effectiveness?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Transmission Pipeline Integrity Management § 192.945 What methods must an operator use to measure program effectiveness? (a) General. An operator must include in its integrity management program methods to measure, on... § 192.7), section 9.4, and the specific measures for each identified threat specified in ASME/ANSI...

  2. Diagnostic Accuracy of the Small Membrane Filtration Method for Diagnosis of Pulmonary Tuberculosis in a High-HIV-Prevalence Setting.

    PubMed

    Boum, Yap; Kim, Soyeon; Orikiriza, Patrick; Acuña-Villaorduña, Carlos; Vinhas, Solange; Bonnet, Maryline; Nyehangane, Dan; Mwanga-Amumpaire, Juliet; Fennelly, Kevin P; Jones-López, Edward C

    2016-06-01

    Sputum acid-fast bacilli (AFB) smear microscopy has suboptimal sensitivity but remains the most commonly used laboratory test to diagnose pulmonary tuberculosis (TB). We prospectively evaluated the small membrane filtration (SMF) method that concentrates AFB in a smaller area to facilitate detection to improve the diagnostic performance of microscopy. We enrolled adults with suspicion of pulmonary TB from health facilities in southwestern Uganda. Clinical history, physical examination, and 3 sputum samples were obtained for direct fluorescent AFB smear, SMF, Xpert MTB/RIF, and MGIT culture media. Sensitivity and specificity were estimated for SMF, AFB smear, and Xpert MTB/RIF, using MGIT as the reference standard. The analysis was stratified according to HIV status. From September 2012 to April 2014, 737 participants were included in the HIV-infected stratum (146 [20.5%] were culture positive) and 313 were in the HIV-uninfected stratum (85 [28%] were culture positive). In HIV-infected patients, the sensitivity of a single SMF was 67.4% (95% confidence interval [CI], 59.9% to 74.1%); for AFB, 68.0% (95% CI, 60.6% to 74.6%); and for Xpert MTB/RIF, 91.0% (95% CI, 85.0% to 94.8%). In HIV-uninfected patients, the corresponding sensitivities were 72.5% (95% CI, 62.1% to 80.9%), 80.3% (95% CI, 70.8% to 87.2%), and 93.5% (95% CI, 85.7% to 97.2%). The specificity for all 3 tests in both HIV groups was ≥96%. In this setting, the SMF method did not improve the diagnostic accuracy of sputum AFB. The Xpert MTB/RIF assay performed well in both HIV-infected and -uninfected groups.

  3. Diagnostic Accuracy of the Small Membrane Filtration Method for Diagnosis of Pulmonary Tuberculosis in a High-HIV-Prevalence Setting.

    PubMed

    Boum, Yap; Kim, Soyeon; Orikiriza, Patrick; Acuña-Villaorduña, Carlos; Vinhas, Solange; Bonnet, Maryline; Nyehangane, Dan; Mwanga-Amumpaire, Juliet; Fennelly, Kevin P; Jones-López, Edward C

    2016-06-01

    Sputum acid-fast bacilli (AFB) smear microscopy has suboptimal sensitivity but remains the most commonly used laboratory test to diagnose pulmonary tuberculosis (TB). We prospectively evaluated the small membrane filtration (SMF) method that concentrates AFB in a smaller area to facilitate detection to improve the diagnostic performance of microscopy. We enrolled adults with suspicion of pulmonary TB from health facilities in southwestern Uganda. Clinical history, physical examination, and 3 sputum samples were obtained for direct fluorescent AFB smear, SMF, Xpert MTB/RIF, and MGIT culture media. Sensitivity and specificity were estimated for SMF, AFB smear, and Xpert MTB/RIF, using MGIT as the reference standard. The analysis was stratified according to HIV status. From September 2012 to April 2014, 737 participants were included in the HIV-infected stratum (146 [20.5%] were culture positive) and 313 were in the HIV-uninfected stratum (85 [28%] were culture positive). In HIV-infected patients, the sensitivity of a single SMF was 67.4% (95% confidence interval [CI], 59.9% to 74.1%); for AFB, 68.0% (95% CI, 60.6% to 74.6%); and for Xpert MTB/RIF, 91.0% (95% CI, 85.0% to 94.8%). In HIV-uninfected patients, the corresponding sensitivities were 72.5% (95% CI, 62.1% to 80.9%), 80.3% (95% CI, 70.8% to 87.2%), and 93.5% (95% CI, 85.7% to 97.2%). The specificity for all 3 tests in both HIV groups was ≥96%. In this setting, the SMF method did not improve the diagnostic accuracy of sputum AFB. The Xpert MTB/RIF assay performed well in both HIV-infected and -uninfected groups. PMID:27030493

  4. Diagnostics of Susabi-nori (Porphyra Yezoensis) by Laser-Induced Fluorescence Method

    NASA Astrophysics Data System (ADS)

    Okamoto, Tamotsu; Nakamura, Yuki; Takahashi, Kunio; Kaneko, Shohei; Shimada, Yuji

    Susabi-nori (Porphyra yezoensis) was diagnosed by means of laser-induced fluorescence (LIF) method. Fluorescence peaks located at approximately 580, 660, 685 and 720 nm were observed in the LIF spectra of Susabi-nori. In the spectrum of the sample infected with the red rot disease, the intensity of 580 nm peak was relatively high as compared with that of the control sample. On the other hand, the intensities of 580 nm and 660 nm peaks drastically decreased by the influence of the chytrid disease. Furthermore, the intensity of the 580 nm peak increased by dipping into fresh water. These results indicate that LIF spectra of Susabi-nori are affected by the diseases and the stress of fresh water and that the diseases and the stress of Susabi-nori can be diagnosed by the LIF method.

  5. [Current diagnostic methods and therapeutic principles in various forms of puerperal endometritis].

    PubMed

    Strizhakov, A N; Lebedev, V A; Baev, O R; Aslanov, A G

    1991-05-01

    A total of 55 puerperants+ with endometritis followed by spontaneous labours (26 females) and cesarean operation (29 females) were studied. A comprehensive study involved echography, hysteroscopy, bacteriological analysis of the uterine content, and histological examination of mucosal curettage of the corpus uteri. Three types of the clinical course of endometritis were identified: 1) in the presence of placental tissue residues; 2) with necrosis of delayed decidual tissue and lochia- or hematometra; and 3) a "pure" type of endometritis without abnormal tissues in the uterus. Uterine curettage was performed in the first type of endometritis, vacuum aspiration of its content was carried out in Type 2. The patients from Group 3 who had the most severe inflammatory process of the uterus underwent its cavity washing with large volumes of cold antiseptic solutions, took detoxifying, ++rheo-vasoactive and protein agents, received immunomodulating and uterotonic therapy. The algorithm developed for management of puerperants+ with postpartum endometritis substantially enhanced the efficiency of therapy and prevented severe septic events in time. PMID:1897670

  6. Method for improved selectivity in photo-activation and detection of molecular diagnostic agents

    DOEpatents

    Wachter, E.A.; Fisher, W.G.; Dees, H.C.

    1998-11-10

    A method for the imaging of a particular volume of plant or animal tissue, wherein the plant or animal tissue contains at least one photo-active molecular agent. The method includes the steps of treating the particular volume of the plant or animal tissue with light sufficient to promote a simultaneous two-photon excitation of the photo-active molecular agent contained in the particular volume of the plant or animal tissue, photo-activating at least one of the at least one photo-active molecular agent in the particular volume of the plant or animal tissue, thereby producing at least one photo-activated molecular agent, wherein the at least one photo-activated molecular agent emits energy, detecting the energy emitted by the at least one photo-activated molecular agent, and producing a detected energy signal which is characteristic of the particular volume of plant or animal tissue. The present invention is also a method for the imaging of a particular volume of material, wherein the material contains at least one photo-active molecular agent. 13 figs.

  7. Method for improved selectivity in photo-activation and detection of molecular diagnostic agents

    DOEpatents

    Wachter, Eric A.; Fisher, Walter G.; Dees, H. Craig

    1998-01-01

    A method for the imaging of a particular volume of plant or animal tissue, wherein the plant or animal tissue contains at least one photo-active molecular agent. The method includes the steps of treating the particular volume of the plant or animal tissue with light sufficient to promote a simultaneous two-photon excitation of the photo-active molecular agent contained in the particular volume of the plant or animal tissue, photo-activating at least one of the at least one photo-active molecular agent in the particular volume of the plant or animal tissue, thereby producing at least one photo-activated molecular agent, wherein the at least one photo-activated molecular agent emits energy, detecting the energy emitted by the at least one photo-activated molecular agent, and producing a detected energy signal which is characteristic of the particular volume of plant or animal tissue. The present invention is also a method for the imaging of a particular volume of material, wherein the material contains at least one photo-active molecular agent.

  8. Methods for improved selectivity in photo-activation and detection of molecular diagnostic agents

    DOEpatents

    Wachter, Eric A.; Fisher, Walter G.; Dees, H. Craig

    2008-03-18

    A method for the imaging of a particular volume of plant or animal tissue, wherein the plant or animal tissue contains at least one photo-active molecular agent. The method comprises the steps of treating the particular volume of the plant or animal tissue with light sufficient to promote a simultaneous two-photon excitation of the photo-active molecular agent contained in the particular volume of the plant or animal tissue, photo-activating at least one of the at least one photo-active molecular agent in the particular volume of the plant or animal tissue, thereby producing at least one photo-activated molecular agent, wherein the at least one photo-activated molecular agent emits energy, detecting the energy emitted by the at least one photo-activated molecular agent, and producing a detected energy signal which is characteristic of the particular volume of plant or animal tissue. The present invention also provides a method for the imaging of a particular volume of material, wherein the material contains at least one photo-active molecular agent.

  9. [Diagnostic evaluation of tubeless methods in the study of external secretions of the pancreas].

    PubMed

    Tsimmerman, Ia S; Zueva, E D

    1997-09-01

    Difficulties of examining the external secretion of the pancreas by direct secretin-pancreozymin test prompted us to try 4 probe-free methods for functional assessment of the pancreas in 33 patients with chronic acalculous cholecystitis, 50 patients with reactive pancreatitis concomitant with duodenal ulcer, chronic duodenal obstruction, etc., and in 22 patients with primary chronic pancreatitis during a relapse. The Benda-Zheltvai method with assessment of the debit of uric excretion of alpha-amylase during three 30-min intervals before and after standard food loading and calculation of the pancreozymin induction coefficient, assessment of the ratio of alpha-amylase and creatinine clearance from their content in the urine, the proserine provocation urotest, and Lasus test for hyperaminoaciduria resultant from exocrine insufficiency of the pancreas were used. The Benda-Zheltvai method proved to be a sensitive and specific test for the diagnosis of exocrine insufficiency of the pancreas; moreover, it can be used for assessing the treatment efficacy. The proserine test helps assess the type and severity of disorders of pancreatic external secretion. The ratio of alpha-amylase to creatinine clearance demonstrates just the most expressed disorders of pancreatic exocrine secretion during the relapse of primary chronic pancreatitis. Lasus test for hyperaminoaciduria detects pancreatic dyscrinia and provides valuable information about the function of the pancreas.

  10. Dolichoectasia Diagnostic Methods in a Multi-Ethnic, Stroke-Free Cohort: Results from the Northern Manhattan Study

    PubMed Central

    Gutierrez, Jose; Bagci, Ahmet; Gardener, Hannah; Rundek, Tatjana; Ekind, Mitchell S. V.; Alperin, Noam; Sacco, Ralph L.; Wright, Clinton B.

    2015-01-01

    BACKGROUND AND PURPOSE Dolichoectasia (DE) is a vasculopathy that consists of abnormal elongation and dilatation of arteries. The objective of this study is to evaluate the frequency of DE in an unselected population and assess different diagnostic methods. METHODS The Northern Manhattan Study is a multiethnic population based cohort of stroke-free participants. The definition proposed for DE was total cranial volume (TCV)-adjusted arterial diameter ≥2 SD. Other methods studied included visual assessment, unadjusted arterial diameters cutoff, Smoker's criteria and basilar artery (BA) volume. RESULTS A total of 718 subjects were included in the analysis (mean age 71.6 ± 8.0 years, 40% men, 61% Hispanic). Using the TCV-adjusted DE definition, 19% of the sample had at least one dolichoectatic artery. In 7% of the subjects, two or more arteries were affected. The BA was the most common dolichoectatic artery. Reproducibility for arterial diameter measurements was good to excellent (.70–.95), while for visual assessment ranged from fair to good (.49–.79). CONCLUSIONS A TCV-adjusted intracranial arterial diameter ≥2 SD is proposed as a useful DE definition. The variability in the prevalence of DE depending on the methods used underscores the need to agree on a reliable, universal definition of DE. PMID:23317292

  11. Diagnostics for the National Compact Stellarator Experiment

    SciTech Connect

    B.C. Stratton; D. Johnson; R. Feder; E. Fredrickson; H. Neilson; H. Takahashi; M. Zarnstorf; M. Cole; P. Goranson; E. Lazarus; B. Nelson

    2003-09-16

    The status of planning of the National Compact Stellarator Experiment (NCSX) diagnostics is presented, with the emphasis on resolution of diagnostics access issues and on diagnostics required for the early phases of operation.

  12. Development of a Model Based Technique for Gear Diagnostics using the Wigner-Ville method

    NASA Technical Reports Server (NTRS)

    Choy, F.; Xu, A.; Polyshchuk, V.

    1997-01-01

    Imperfections in gear tooth geometry often result from errors in the manufacturing process or excessive material wear during operation. Such faults in the gear tooth geometry can result in large vibrations in the transmission system, and, in some cases, may lead to early failure of the gear transmission system. This report presents the study of the effects of imperfection in gear tooth geometry on the dynamic characteristics of a gear transmission system. The faults in the gear tooth geometry are modeled numerically as the deviation of the tooth profile from its original involute geometry. The changes in gear mesh stiffness due to various profile and pattern variations are evaluated numerically. The resulting changes in the mesh stiffness are incorporated into a computer code to simulate the dynamics of the gear transmission system. A parametric study is performed to examine the sensitivity of gear tooth geometry imperfections on the vibration of a gear transmission system. The parameters variations in this study consist of the magnitude of the imperfection, the pattern of the profile variation, and the total number of teeth affected. Numerical results from the dynamic simulations are examined in both the time and the frequency domains. A joint time-frequency analysis procedure using the Wigner-Ville Distribution is also introduced to identify the location of the damaged tooth from the vibration signature. Numerical simulations of the system dynamics with gear faults were compared to experimental results. An optimal tracker was introduced to quantify the level of damage in the gear mesh system. Conclusions are drawn from the results of this numerical study.

  13. [Commemorative lecture of receiving Imamura Memorial Prize. I. Studies on bacteriological diagnostic methods for mycobacteria].

    PubMed

    Abe, C

    1994-08-01

    Two systems, radiometric BACTEC and biphasic MB-Check, based on liquid media proved to be significantly better than the egg-based solid media for the isolation of mycobacteria from clinical specimens. The difference in the rates of isolation of mycobacteria between two groups of media was more remarkable with smear-negative specimens. The time to the detection of the Mycobacterium tuberculosis complex with MB- Check was shorter than that with the 3% Ogawa egg method but longer than that with BACTEC. The polymerase chain reaction (PCR) using oligonucleotides based on the repetitive sequence (IS986) of M. tuberculosis as a primer and the Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test (MTD), which combines an M. tuberculosis rRNA amplification method with the hybridization protection assay format, were evaluated for detection of M. tuberculosis in clinical samples. Although the sensitivities of the PCR and MTD appeared to be similar to that of culture with the MB-Check system, the two methods based on nucleic acid amplification should be very useful for rapid detection of M. tuberculosis infections without the long time required for culture of M. tuberculosis. Epidemiological studies with techniques which allow differentiation of strains within M. tuberculosis groups are important for limiting the dissemination of the disease. We analyzed six groups of small outbreaks of M. tuberculosis infections by restriction fragment length polymorphism (RFLP) analysis. Five showed identical fingerprints within each group, but one which as also suspected to have a common source of infection showed different banding patterns, emphasizing that RFLP analysis using IS986 as a probe is useful in epidemiological studies of tuberculosis.(ABSTRACT TRUNCATED AT 250 WORDS)

  14. [Commemorative lecture of receiving Imamura Memorial Prize. I. Studies on bacteriological diagnostic methods for mycobacteria].

    PubMed

    Abe, C

    1994-08-01

    Two systems, radiometric BACTEC and biphasic MB-Check, based on liquid media proved to be significantly better than the egg-based solid media for the isolation of mycobacteria from clinical specimens. The difference in the rates of isolation of mycobacteria between two groups of media was more remarkable with smear-negative specimens. The time to the detection of the Mycobacterium tuberculosis complex with MB- Check was shorter than that with the 3% Ogawa egg method but longer than that with BACTEC. The polymerase chain reaction (PCR) using oligonucleotides based on the repetitive sequence (IS986) of M. tuberculosis as a primer and the Gen-Probe Amplified Mycobacterium Tuberculosis Direct Test (MTD), which combines an M. tuberculosis rRNA amplification method with the hybridization protection assay format, were evaluated for detection of M. tuberculosis in clinical samples. Although the sensitivities of the PCR and MTD appeared to be similar to that of culture with the MB-Check system, the two methods based on nucleic acid amplification should be very useful for rapid detection of M. tuberculosis infections without the long time required for culture of M. tuberculosis. Epidemiological studies with techniques which allow differentiation of strains within M. tuberculosis groups are important for limiting the dissemination of the disease. We analyzed six groups of small outbreaks of M. tuberculosis infections by restriction fragment length polymorphism (RFLP) analysis. Five showed identical fingerprints within each group, but one which as also suspected to have a common source of infection showed different banding patterns, emphasizing that RFLP analysis using IS986 as a probe is useful in epidemiological studies of tuberculosis.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7933779

  15. Guide waves-based multi-damage identification using a local probability-based diagnostic imaging method

    NASA Astrophysics Data System (ADS)

    Gao, Dongyue; Wu, Zhanjun; Yang, Lei; Zheng, Yuebin

    2016-04-01

    Multi-damage identification is an important and challenging task in the research of guide waves-based structural health monitoring. In this paper, a multi-damage identification method is presented using a guide waves-based local probability-based diagnostic imaging (PDI) method. The method includes a path damage judgment stage, a multi-damage judgment stage and a multi-damage imaging stage. First, damage imaging was performed by partition. The damage imaging regions are divided into beside damage signal paths. The difference in guide waves propagation characteristics between cross and beside damage paths is proposed by theoretical analysis of the guide wave signal feature. The time-of-flight difference of paths is used as a factor to distinguish between cross and beside damage paths. Then, a global PDI method (damage identification using all paths in the sensor network) is performed using the beside damage path network. If the global PDI damage zone crosses the beside damage path, it means that the discrete multi-damage model (such as a group of holes or cracks) has been misjudged as a continuum single-damage model (such as a single hole or crack) by the global PDI method. Subsequently, damage imaging regions are separated by beside damage path and local PDI (damage identification using paths in the damage imaging regions) is performed in each damage imaging region. Finally, multi-damage identification results are obtained by superimposing the local damage imaging results and the marked cross damage paths. The method is employed to inspect the multi-damage in an aluminum plate with a surface-mounted piezoelectric ceramic sensors network. The results show that the guide waves-based multi-damage identification method is capable of visualizing the presence, quantity and location of structural damage.

  16. Conventional parasitology and DNA-based diagnostic methods for onchocerciasis elimination programmes.

    PubMed

    Lloyd, Melanie M; Gilbert, Rebecca; Taha, Nathalie Tebao; Weil, Gary J; Meite, Aboulaye; Kouakou, Ilunga M M; Fischer, Peter U

    2015-06-01

    Commonly used methods for diagnosing Onchocerca volvulus infections (microscopic detection of microfilariae in skin snips and nodule palpation) are insensitive. Improved methods are needed for monitoring and evaluation of onchocerciasis elimination programmes and for clinical diagnosis of individual patients. A sensitive probe-based qPCR assay was developed for detecting O. volvulus DNA, and this was tested with samples collected from an endemic area in eastern Côte d'Ivoire. The new test was evaluated with dried skin snip pairs from 369 subjects and compared to routine skin snip microscopy and nodule palpation results from the same individuals. Onchocerciasis prevalence for these samples by qPCR, skin snip microscopy, and nodule palpation were 56.9%, 26.0%, and 37.9%, respectively. Furthermore, the combination of all three tests produced an infection prevalence of 72.9%, which was significantly higher than 53.1% detected by microscopy plus nodule palpation without qPCR. However, the qPCR assay was negative for 54 of 229 individuals with palpable nodules. qPCR could be a useful tool for detecting residual O. volvulus infections in human populations as prevalence decreases in areas following community-directed treatment with ivermectin. PMID:25818324

  17. Liver fibrosis in human immunodeficiency virus/hepatitis C virus coinfection: Diagnostic methods and clinical impact

    PubMed Central

    Sagnelli, Caterina; Martini, Salvatore; Pisaturo, Mariantonietta; Pasquale, Giuseppe; Macera, Margherita; Zampino, Rosa; Coppola, Nicola; Sagnelli, Evangelista

    2015-01-01

    Several non-invasive surrogate methods have recently challenged the main role of liver biopsy in assessing liver fibrosis in hepatitis C virus (HCV)-monoinfected and human immunodeficiency virus (HIV)/HCV-coinfected patients, applied to avoid the well-known side effects of liver puncture. Serological tests involve the determination of biochemical markers of synthesis or degradation of fibrosis, tests not readily available in clinical practice, or combinations of routine tests used in chronic hepatitis and HIV/HCV coinfection. Several radiologic techniques have also been proposed, some of which commonly used in clinical practice. The studies performed to compare the prognostic value of non-invasive surrogate methods with that of the degree of liver fibrosis assessed on liver tissue have not as yet provided conclusive results. Each surrogate technique has shown some limitations, including the risk of over- or under-estimating the extent of liver fibrosis. The current knowledge on liver fibrosis in HIV/HCV-coinfected patients will be summarized in this review article, which is addressed in particular to physicians involved in this setting in their clinical practice. PMID:26523204

  18. The Visualization of Biofilms in Chronic Diabetic Foot Wounds Using Routine Diagnostic Microscopy Methods

    PubMed Central

    Bowling, Frank L.; Boulton, Andrew J. M.; Bowler, Philip G.; Metcalf, Daniel G.; McBain, Andrew J.

    2014-01-01

    Diabetic foot wounds are commonly colonised by taxonomically diverse microbial communities and may additionally be infected with specific pathogens. Since biofilms are demonstrably less susceptible to antimicrobial agents than are planktonic bacteria, and may be present in chronic wounds, there is increasing interest in their aetiological role. In the current investigation, the presence of structured microbial assemblages in chronic diabetic foot wounds is demonstrated using several visualization methods. Debridement samples, collected from the foot wounds of diabetic patients, were histologically sectioned and examined using bright-field, fluorescence, and environmental scanning electron microscopy and assessed by quantitative differential viable counting. All samples (n = 26) harboured bioburdens in excess of 5 log10 CFU/g. Microcolonies were identified in 4/4 samples by all three microscopy methods, although bright-field and fluorescence microscopy were more effective at highlighting putative biofilm morphology than ESEM. Results in this pilot study indicate that bacterial microcolonies and putative biofilm matrix can be visualized in chronic wounds using florescence microscopy and ESEM, but also using the simple Gram stain. PMID:24839608

  19. [Molecular diagnostic methods of respiratory infections. Has the scheme diagnosis changed?].

    PubMed

    Vila Estapé, Jordi; Zboromyrska, Yuliya; Vergara Gómez, Andrea; Alejo Cancho, Izaskun; Rubio García, Elisa; Álvarez-Martínez, Miriam José; la Bellacasa Brugada, Jorge Puig de; Marcos Maeso, M Ángeles

    2016-07-01

    Lower respiratory tract infections remain one of the most common causes of mortality worldwide, which is why early diagnosis is crucial. Traditionally the microbiological diagnosis of these infections has been based on conventional methods including culture on artificial media for isolation of bacteria and fungi and cell cultures for virus and antibody or antigen detection using antigen-antibody reactions. The main drawback of the above mentioned methods is the time needed for an etiological diagnosis of the infection. The techniques based on molecular biology have drawn much attention in recent decades as tools for rapid diagnosis of infections. Some techniques are very expensive, especially those that can detect various microorganisms in the same reaction, therefore the question that arises is whether the cost of such testing is justified by the information obtained and by the clinical impact that its implementation will determine. In this article we make a review of the various techniques of molecular biology applied to the diagnosis of pneumonia and focus primarily on analysing the impact they may have on the management of patients with acute respiratory tract infections.

  20. [Comparison of the diagnostic methods for studying parvovirus and rotavirus infections of dogs].

    PubMed

    Kölbl, S; Vogel, I; Modli, M; Gerstl, F

    1990-07-01

    79 feces samples of dogs between 7 weeks till 13.5 years of age, showing clinical signs of a hemorrhagic gastroenteritis, were tested by a commercial ELISA (DiaSystems Canine Parvo, Tech-America) for Canine Parvovirus (CPV) and by two Latex-Agglutination tests for Rotavirus (30 probes were tested by Rota Screen, 49 samples by Slidex Rota-Kit 2, both tests from BioMerieux). All samples were also examined by electron microscopy. The results of the simultaneous investigations showed 28 times positive and 28 times negative for CPV (70.9%). In 93.7% the investigations for Rotavirus-infection showed identical results by the Latex-Agglutination and electron microscopy: 73 samples were negative, one case showed a positive reaction. In 4 feces samples Rotavirus could only be detected by the Latex-test. In one sample a double-infection (CPV/Rotavirus) could be observed by all methods, in two cases the double-infection was only found by using the Latex-Agglutination. No other viruses could be found by the electron microscope than those described above. The results and the performance of the methods are discussed and compared with the data of other authors. PMID:2167658

  1. Evaluation of Diagnostic Methods in the Differentiation of Heart Murmurs in Children

    PubMed Central

    Begic, Zijo; Dinarevic, Senka Mesihovic; Pesto, Senad; Begic, Edin; Dobraca, Amra; Masic, Izet

    2016-01-01

    Introduction: The most common clinical sign in pediatric cardiology is a heart murmur (organic and inorganic). Organic are sign of heart disease, while inorganic (basically divided into accidental and functional) murmurs occur on anatomically healthy heart. Aim: To determine the justification of the application of the methods of cardiac treatment. Patients and methods: Study included 116 children aged from 1 to 15 years, who were referred due to cardiac treatment to Pediatric Clinic, of Sarajevo University Clinical Center. Results: The first group consisted of children with innocent heart murmur, 97 (53 males). The second group consisted of patients with organic murmur, 19 (13 males). The average age of the first group was 7.69 (1.01–15.01) years old, and of the second group 3.15 (1.01- 8.06) years old, and there is a significant difference between these two groups (p <0.001). Medical history questions about potentially harmful habits of mother in pregnancy, found significant differences in the frequency of the existence of habits between the first and second groups of subjects (14.44% vs. 85.1%, p = 0.013). The values of the pulse of patients showed statistically significant difference (p = 0.012). The most common place of the murmurs’ appearance is the second left intercostal space. In the first group, the most common were vibratory (32.3%) and ejection (31.9%) and in the second the most common were holosystolic (73.7%) murmur. Analyzing the R/S ratio of V1, a significant difference among the two groups was found (mean 0.78 vs. the values for 1.45, p = 0.003). There is a significance in terms of developed hypertrophy of the heart cavities (BVH) between the two groups. The most common accidental murmur was classic vibratory Still’s murmurs (55.43%) and the most common congenital heart defects was ASD (36.8%). Conclusions: A heart murmur itself, should not be the purpose of auscultation. One of the tasks of pediatricians, pediatric cardiologists in particular

  2. [Validity of diagnostic methods for kidney function tests in the cat].

    PubMed

    Meyer-Lindenberg, A; Westhoff, A; Wohlsein, P; Nolte, I

    1996-08-01

    The diagnosis of kidney disease is difficult in the stage of compensation and impossible based solely on the routinely performed laboratory tests on blood and urine. For this reason, more sensitive methods are required. In the present study, three special techniques are compared with regard to their validity in the early diagnosis of kidney disease in the cat: 1. the molecular-weight related separation of urine proteins with the sodium-dodecyl-sulfate-polyacrylamide-gradient gel electrophoresis (SDS-page) in the PhastSystem, 2. measurement of the glomerular filtration rate (GFR) with the renalyzer PRX90 using an iodine containing contrast medium and 3. kidney scintigraphy. The results of this comparison demonstrate that these procedures are important adjuncts to common laboratory investigations in the testing of renal function. The SDS-page allows an early qualitative assessment on alterations of specific functional compartments of the kidney. However, it is not possible with this method alone to evaluate the degree of renal disturbance and it does not give information concerning the severity of renal functional impairment. Measurement of the GFR is also a valuable procedure which gives a quantitative result on the global renal function within a few hours. It is of special importance when subclinically disturbed kidney function is present. In the cat however it is until now not possible to give a correct prognosis in high grade nephropathies. Only scintigraphy allows unilateral assessment of renal function, which is most important in cats with morphologically altered kidneys, such as kidney cysts, hydronephrosis or tumours. PMID:9012026

  3. Applying Automated MR-Based Diagnostic Methods to the Memory Clinic: A Prospective Study.

    PubMed

    Klöppel, Stefan; Peter, Jessica; Ludl, Anna; Pilatus, Anne; Maier, Sabrina; Mader, Irina; Heimbach, Bernhard; Frings, Lars; Egger, Karl; Dukart, Juergen; Schroeter, Matthias L; Perneczky, Robert; Häussermann, Peter; Vach, Werner; Urbach, Horst; Teipel, Stefan; Hüll, Michael; Abdulkadir, Ahmed

    2015-01-01

    Several studies have demonstrated that fully automated pattern recognition methods applied to structural magnetic resonance imaging (MRI) aid in the diagnosis of dementia, but these conclusions are based on highly preselected samples that significantly differ from that seen in a dementia clinic. At a single dementia clinic, we evaluated the ability of a linear support vector machine trained with completely unrelated data to differentiate between Alzheimer's disease (AD), frontotemporal dementia (FTD), Lewy body dementia, and healthy aging based on 3D-T1 weighted MRI data sets. Furthermore, we predicted progression to AD in subjects with mild cognitive impairment (MCI) at baseline and automatically quantified white matter hyperintensities from FLAIR-images. Separating additionally recruited healthy elderly from those with dementia was accurate with an area under the curve (AUC) of 0.97 (according to Fig. 4). Multi-class separation of patients with either AD or FTD from other included groups was good on the training set (AUC >  0.9) but substantially less accurate (AUC = 0.76 for AD, AUC = 0.78 for FTD) on 134 cases from the local clinic. Longitudinal data from 28 cases with MCI at baseline and appropriate follow-up data were available. The computer tool discriminated progressive from stable MCI with AUC = 0.73, compared to AUC = 0.80 for the training set. A relatively low accuracy by clinicians (AUC = 0.81) illustrates the difficulties of predicting conversion in this heterogeneous cohort. This first application of a MRI-based pattern recognition method to a routine sample demonstrates feasibility, but also illustrates that automated multi-class differential diagnoses have to be the focus of future methodological developments and application studies.

  4. Diagnostic Applications and Methods to Isolate Circulating Tumor Cells (CTCs) from Blood

    NASA Astrophysics Data System (ADS)

    Tang, Cha-Mei

    2013-03-01

    Each year a million new cancer cases are diagnosed in the United States. Ninety percent of the deaths will be the result of metastasis, not from the primary tumor. Tissue biopsy is a universally accepted tool for cancer diagnosis and determination of treatment. The procedure varies, but is invasive, costly, and can be fatal, and for these reasons is seldom repeated after initial diagnosis. Monitoring of treatment response and for possible relapse is usually done by CT or MRI scan, both of which are expensive and require the tumor to change size perceptibly. Further, cancer can mutate or develop resistance to therapeutics and require modification of the treatment regimen. The initial tissue biopsy often cannot reflect the disease as it progresses, requiring new biopsy samples to determine a change of treatment. All carcinomas, about 80% of all cancer, shed tumor cells into the circulation, most often at the later stages when treatment is more critical. These circulating tumor cells (CTCs) are the cause of metastasis, and can be isolated from patient blood to serve as ``liquid biopsy''. These CTCs contain a valuable trove of information that help both patient and clinician understand disease status. In addition to counting the number of CTCs (known to be a prognostic indicator of survival), CTCs can provide biomarker information such as protein expressions and gene mutations, amplifications, and translocations. This information can be used to determine treatment. During treatment, the number of intact and apoptotic CTCs can be measured on a repeated basis to measure the patient's response to treatment and disease progression. Following treatment, liquid biopsy can be repeated at regular intervals to watch for relapse. Methods to isolate CTCs can be grouped into three categories: i) immunocapture based on surface markers of CTCs, ii) size exclusion based on CTC size, typically larger than blood cells, and iii) negative selection utilizing red blood cell lysis, white

  5. Applying Automated MR-Based Diagnostic Methods to the Memory Clinic: A Prospective Study.

    PubMed

    Klöppel, Stefan; Peter, Jessica; Ludl, Anna; Pilatus, Anne; Maier, Sabrina; Mader, Irina; Heimbach, Bernhard; Frings, Lars; Egger, Karl; Dukart, Juergen; Schroeter, Matthias L; Perneczky, Robert; Häussermann, Peter; Vach, Werner; Urbach, Horst; Teipel, Stefan; Hüll, Michael; Abdulkadir, Ahmed

    2015-01-01

    Several studies have demonstrated that fully automated pattern recognition methods applied to structural magnetic resonance imaging (MRI) aid in the diagnosis of dementia, but these conclusions are based on highly preselected samples that significantly differ from that seen in a dementia clinic. At a single dementia clinic, we evaluated the ability of a linear support vector machine trained with completely unrelated data to differentiate between Alzheimer's disease (AD), frontotemporal dementia (FTD), Lewy body dementia, and healthy aging based on 3D-T1 weighted MRI data sets. Furthermore, we predicted progression to AD in subjects with mild cognitive impairment (MCI) at baseline and automatically quantified white matter hyperintensities from FLAIR-images. Separating additionally recruited healthy elderly from those with dementia was accurate with an area under the curve (AUC) of 0.97 (according to Fig. 4). Multi-class separation of patients with either AD or FTD from other included groups was good on the training set (AUC >  0.9) but substantially less accurate (AUC = 0.76 for AD, AUC = 0.78 for FTD) on 134 cases from the local clinic. Longitudinal data from 28 cases with MCI at baseline and appropriate follow-up data were available. The computer tool discriminated progressive from stable MCI with AUC = 0.73, compared to AUC = 0.80 for the training set. A relatively low accuracy by clinicians (AUC = 0.81) illustrates the difficulties of predicting conversion in this heterogeneous cohort. This first application of a MRI-based pattern recognition method to a routine sample demonstrates feasibility, but also illustrates that automated multi-class differential diagnoses have to be the focus of future methodological developments and application studies. PMID:26401773

  6. The usefulness of the leuprolide stimulation test as a diagnostic method of idiopathic central precocious puberty in girls.

    PubMed

    Carretto, F; Salinas-Vert, I; Granada-Yvern, M L; Murillo-Vallés, M; Gómez-Gómez, C; Puig-Domingo, M; Bel, J

    2014-12-01

    Central precocious puberty (CPP) diagnosis is based on clinical evaluation, but hormonal evaluation is crucial. The aim of the study was to evaluate the usefulness of the leuprolide stimulation test for diagnosis of idiopathic CPP. Sixty-one girls, aged 5-8 years, were evaluated retrospectively for premature breast development. According to clinical evolution, 28 had progressive puberty and 33 nonprogressive puberty. All underwent a leuprolide stimulation test. Cutoff points, sensitivity, and specificity for gonadotropins and estradiol were determined by receiver operating characteristic (ROC) curves. Cutoff points for CPP were: baseline LH: > 0.1 mUI/l, FSH: > 2.3 mUI/l, LH/FSH ratio: > 0.23, estradiol: > 12 pg/ml; and stimulated LH: > 5.5 mUI/l, LH/FSH ratio: > 0.24, estradiol: > 79.67 pg/ml. The best diagnostic efficiency for progressive puberty were stimulated LH/FSH ratio (sensitivity: 100%, specificity 94%) followed by stimulated LH (sensitivity: 93%, specificity: 100%). Stimulated LH/FSH ratio and LH resulted in the most useful parameters for the diagnosis of CPP. Stimulated estradiol did not add more information.

  7. Devices and methods of operation thereof for providing stable flow for centrifugal compressors

    NASA Technical Reports Server (NTRS)

    Skoch, Gary J. (Inventor); Stevens, Mark A. (Inventor); Jett, Thomas A. (Inventor)

    2008-01-01

    Centrifugal compressor flow stabilizing devices and methods of operation thereof are disclosed that act upon the flow field discharging from the impeller of a centrifugal compressor and modify the flow field ahead of the diffuser vanes such that flow conditions contributing to rotating stall and surge are reduced or even eliminated. In some embodiments, shaped rods and methods of operation thereof are disclosed, whereas in other embodiments reverse-tangent air injection devices and methods are disclosed.

  8. Comparative analysis of the methods of drug and protein delivery for the treatment of cancer, genetic diseases and diagnostics.

    PubMed

    Todorova, Roumiana

    2011-11-01

    The methods of protein and drug delivery for the treatment of cancer, genetic diseases and diagnostics were summarized. The potential of protein transduction is discussed and the recent developments in the field are reviewed. An overview is provided of the non-viral delivery methods such as liposomes, polymer-based delivery, cell-penetrating peptides, bacterial secretion, cells, virosomes, physical methods including electroporation, microinjection, osmotic lysis, nanoparticles, sonoporation to locally inject therapeutic molecules. The characteristic properties of non-viral vectors and their use for the delivery of therapeutic molecules for the diagnosis and treatment of disorders and to target tumors are also discussed. The potential of the transduced peptides and proteins was used as new therapeutic compounds against infectious diseases, to complement deficiencies in specific genes, to specifically kill tumour cells, for gene therapy. The protein delivery vectors can enhance the transfection at low concentrations and help to develop future gene delivery systems with reduced toxicity. Vitamin B12, folic acid, biotin, and riboflavin are essential in the treatment of cancer. Ultrasound has a potential in the delivery of therapeutic agents. The new developing technologies of drug delivery and targeting offer the possibility to improve the therapeutic possibilities of the existing drugs and to develop novel therapeutics.

  9. Measurement and Analysis of Olfactory Responses with the Aim of Establishing an Objective Diagnostic Method for Central Olfactory Disorders

    NASA Astrophysics Data System (ADS)

    Uno, Tominori; Wang, Li-Qun; Miwakeichi, Fumikazu; Tonoike, Mitsuo; Kaneda, Teruo

    In order to establish a new diagnostic method for central olfactory disorders and to identify objective indicators, we measured and analyzed brain activities in the parahippocampal gyrus and uncus, region of responsibility for central olfactory disorders. The relationship between olfactory stimulation and brain response at region of responsibility can be examined in terms of fitted responses (FR). FR in these regions may be individual indicators of changes in brain olfactory responses. In the present study, in order to non-invasively and objectively measure olfactory responses, an odor oddball task was conducted on four healthy volunteers using functional magnetic resonance imaging (fMRI) and a odorant stimulator with blast-method. The results showed favorable FR and activation in the parahippocampal gyrus or uncus in all subjects. In some subjects, both the parahippocampal gyrus and uncus were activated. Furthermore, activation was also confirmed in the cingulate gyrus, middle frontal gyrus, precentral gyrus, postcentral gyrus, superior temporal gyrus and insula. The hippocampus and uncus are known to be involved in the olfactory disorders associated with early-stage Alzheimer's disease and other olfactory disorders. In the future, it will be necessary to further develop the present measurement and analysis method to clarify the relationship between central olfactory disorders and brain activities and establish objective indicators that are useful for diagnosis.

  10. Diagnostic analysis of turbulent boundary layer data by a trivariate Lagrangian partitioning method

    SciTech Connect

    Welsh, P.T.

    1994-12-31

    The rapid scientific and technological advances in meteorological theory and modeling predominantly have occurred on the large (or synoptic) scale flow characterized by the extratropical cyclone. Turbulent boundary layer flows, in contrast, have been slower in developing both theoretically and in accuracy for several reasons. There are many existing problems in boundary layer models, among them are limits to computational power available, the inability to handle countergradient fluxes, poor growth matching to real boundary layers, and inaccuracy in calculating the diffusion of scalar concentrations. Such transport errors exist within the boundary layer as well as into the free atmosphere above. This research uses a new method, which can provide insight into these problems, and ultimately improve boundary layer models. There are several potential applications of the insights provided by this approach, among them are estimation of cloud contamination of satellite remotely sensed surface parameters, improved flux and vertical transport calculations, and better understanding of the diurnal boundary layer growth process and its hysteresis cycle.

  11. Poisoning of wild birds from exposure to anticholinesterase compounds and lead: diagnostic methods and selected cases

    USGS Publications Warehouse

    Franson, J.C.; Smith, M.R.

    1999-01-01

    Organophosphorus and carbamate compounds have largely replaced chlorinated hydrocarbons for pesticidal use in the United States, and many cases of poisoning resulting from exposure to these anticholinesterase agents have occurred in free-living birds. Although lead shot has been prohibited for waterfowl hunting throughout the United States since 1991, lead poisoning from the ingestion of spent lead shot is still occasionally seen in wild birds, and lead poisoning from the ingestion of fishing sinkers is an emerging issue of concern. A thorough history, a complete necropsy evaluation, and appropriate laboratory analysis of tissues are required to diagnose toxicoses in wild birds, including those caused by anticholinesterase compounds and lead. The interpretation of brain cholinesterase (ChE) activity results depends on the methods of analysis and comparison with expected normal enzyme activities in brain tissue from the same species. Although lead residues in tissues vary among species, many lead poisoned birds have tissue residues that are much higher than the lower threshold commonly accepted for a diagnosis of lead poisoning. We review histories, necropsy findings, and analytical methodologies and results for selected anticholinesterase and lead poisoning cases diagnosed in wild raptors, waterfowl, and loons.

  12. Clinical diagnostic of pleural effusions using a high-speed viscosity measurement method

    NASA Astrophysics Data System (ADS)

    Hurth, Cedric; Klein, Katherine; van Nimwegen, Lena; Korn, Ronald; Vijayaraghavan, Krishnaswami; Zenhausern, Frederic

    2011-08-01

    We present a novel bio-analytical method to discriminate between transudative and exudative pleural effusions based on a high-speed video analysis of a solid glass sphere impacting a liquid. Since the result depends on the solution viscosity, it can ultimately replace the battery of biochemical assays currently used. We present results obtained on a series of 7 pleural effusions obtained from consenting patients by analyzing both the splash observed after the glass impactor hits the liquid surface, and in a configuration reminiscent of the drop ball viscometer with added sensitivity and throughput provided by the high-speed camera. The results demonstrate distinction between the pleural effusions and good correlation with the fluid chemistry analysis to accurately differentiate exudates and transudates for clinical purpose. The exudative effusions display a viscosity around 1.39 ± 0.08 cP whereas the transudative effusion was measured at 0.89 ± 0.09 cP, in good agreement with previous reports.

  13. Non-invasive diagnostic methods for investigating the quality of Žilina airport's runway

    NASA Astrophysics Data System (ADS)

    Slabej, Martin; Grinč, Michal; Kováč, Matúš; Decký, Martin; Šedivý, Štefan

    2015-09-01

    The Žilina airport was after almost 50 years of use measured by non-invasive methods including GPR and Profilograph GE in order to investigate the quality of the runway pavement at the chosen spots. Since it was just a pilot action, a sample of survey was carried out. The testing spots were placed where the geologic drill core J02 have been drilled out. The measurements performed by Profilograph GE were used to verify the quality of the pavement surface in term longitudinal unevenness by means of index IRI and C. The GPR survey was performed in 3D geometry, hence in the x- and y-direction. A horn type antenna with central frequency of 2 GHz was used on the test field in order to verify the thicknesses of pavement construction layers. Here, the result of a 3D survey is presented. The investigation confirms two sub-horizontal construction layers of the runway pavement. In some areas the GPR interpretation was not possible due to the signal attenuation. This significant signal attenuation is found mainly in the areas where the linear cracks are situated.

  14. Comparison of three diagnostic methods for the detection of Toxoplasma gondii in free range chickens.

    PubMed

    Hamidinejat, H; Nabavi, L; Mayahi, M; Ghourbanpoor, M; Pourmehdi Borojeni, M; Norollahi Fard, S; Shokrollahi, M

    2014-09-01

    Detection of Toxoplasma gondii in free range chickens is an indicator of the prevalence and distribution pattern of T. gondii in the environment. For this purpose, serologic assays especially modified agglutination test (MAT) is the main approach in the literature. The main goal of this study was to compare the polymerase chain reaction (PCR) based on amplification of first internal transcribed spacer (ITS-1) of ribosomal DNA gene, ELISA, and MAT to demonstrate T. gondii infection in free range chicken. A total of 106 adult free - range chickens were killed. Blood, whole heart and brain samples were taken. Sera were examined for the presence of T. gondii antibodies by ELISA and MAT as well. Selected tissues were used for PCR and bioassay in mice. The results revealed that 48.11%, 51.89%, 46.23% and 27.36% of chickens were positive in ELISA, MAT, PCR and bioassay in mice respectively. Good correlation between the results of PCR, ELISA and MAT were detected, but not with bioassay in mice. Compared with PCR, the sensitivity and specificity of ELISA were 92.16% and 96.36% respectively and also for MAT, the sensitivity was 81.81% and the specificity was 92.15%. The specific diagnosis of T. gondii infection in chickens is central to a better understanding of the epidemiology and dynamics of transmission among the various host population and is particularly important for planning effective optimal prevention and control programs. Our data in the present study demonstrated that PCR, ELISA and the MAT are helpful and precise methods to detect T. gondii in naturally infected free-range chickens.

  15. Detection of human papilloma virus in women referred for colposcopy. A comparison between different diagnostic methods.

    PubMed

    Bodén, E; Evander, M; Wadell, G; Bjersing, L; von Schoultz, B; Rylander, E

    1990-01-01

    Various methods presently available for the diagnosis of genital Human Papilloma Virus (HPV) were compared regarding their sensitivity in women referred for specific diagnosis and treatment because of atypical Pap smears or clinically suspected neoplasia. Colposcopic examination was performed in all cases. In addition to taking a second Pap smear, cell suspensions were made from 105 women and analysed by the Filter In Situ Hybridization (FISH) technique and tested for HPV 6 + 11 and HPV 16 + 18 + 31. The FISH technique was also used for the possible detection of HPV-DNA in a reference material comprising 119 apparently healthy women with normal Pap smears. Colposcopically directed cervical biopsies in altogether 196 specimens were obtained from 155 women for histopathological examination and also for the detection of HPV-DNA by the Southern blot hybridization technique. These specimens were tested for the presence of HPV 6, 11, 16, 18, 31 and 33. Three per cent of the women with and 34% without cytological signs of HPV in Pap smears had cervical intraepithelial neoplasia (CIN) III according to histopatology. CIN III was present in 35% of biopsies with and 59% of biopsies without histological signs of HPV in the biopsies. Altogether 46% of the women were HPV-DNA positive. Of the women analysed by Southern blot, 39% were HPV-DNA positive. Of the samples analysed by FISH, 27% with atypical cells were HPV-DNA positive, compared with 11% of the samples from reference women with normal cytology.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2166988

  16. Capacity-loss diagnostic and life-time prediction in lithium-ion batteries: Part 1. Development of a capacity-loss diagnostic method based on open-circuit voltage analysis

    NASA Astrophysics Data System (ADS)

    Wang, Tiansi; Pei, Lei; Wang, Tingting; Lu, Rengui; Zhu, Chunbo

    2016-01-01

    Effective capacity-loss diagnosis and life-time prediction are the foundations of battery second-use technology and will play an important role in the development of the new energy industry. Of the two, the capacity-loss diagnostic, as a precondition of the life-time prediction, needs to be studied first. Performing a capacity-loss diagnosis for an aging cell consists of finding the decisive degradation mechanisms for the cell's capacity degradation. Because a cell's capacity just equals the span of the open-circuit voltage (OCV), when suspect degradation mechanisms affect a cell's capacity, they will leave corresponding and particular clues in the OCV curve. Taking a cell's OCV as the diagnostic indicator, a multi-mechanistic and non-destructive diagnostic method is developed in this paper. To establish an unambiguous relationship between OCV changes and the combinations of the decisive mechanisms, all the possible OCV changes under various aging situations are systematically analyzed based on a novel simultaneous coordinate system, in which the effects of each suspect capacity-loss mechanism on the OCV curve can be clearly represented. As a summary of the analysis results, a straightforward diagnostic flowchart is presented. By following the flowchart, an aging cell can be diagnosed within three steps by observation of the OCV changes.

  17. Development of a quantitative diagnostic method of estrogen receptor expression levels by immunohistochemistry using organic fluorescent material-assembled nanoparticles.

    PubMed

    Gonda, Kohsuke; Miyashita, Minoru; Watanabe, Mika; Takahashi, Yayoi; Goda, Hideki; Okada, Hisatake; Nakano, Yasushi; Tada, Hiroshi; Amari, Masakazu; Ohuchi, Noriaki

    2012-09-28

    The detection of estrogen receptors (ERs) by immunohistochemistry (IHC) using 3,3'-diaminobenzidine (DAB) is slightly weak as a prognostic marker, but it is essential to the application of endocrine therapy, such as antiestrogen tamoxifen-based therapy. IHC using DAB is a poor quantitative method because horseradish peroxidase (HRP) activity depends on reaction time, temperature and substrate concentration. However, IHC using fluorescent material provides an effective method to quantitatively use IHC because the signal intensity is proportional to the intensity of the photon excitation energy. However, the high level of autofluorescence has impeded the development of quantitative IHC using fluorescence. We developed organic fluorescent material (tetramethylrhodamine)-assembled nanoparticles for IHC. Tissue autofluorescence is comparable to the fluorescence intensity of quantum dots, which are the most representative fluorescent nanoparticles. The fluorescent intensity of our novel nanoparticles was 10.2-fold greater than quantum dots, and they did not bind non-specifically to breast cancer tissues due to the polyethylene glycol chain that coated their surfaces. Therefore, the fluorescent intensity of our nanoparticles significantly exceeded autofluorescence, which produced a significantly higher signal-to-noise ratio on IHC-imaged cancer tissues than previous methods. Moreover, immunostaining data from our nanoparticle fluorescent IHC and IHC with DAB were compared in the same region of adjacent tissues sections to quantitatively examine the two methods. The results demonstrated that our nanoparticle staining analyzed a wide range of ER expression levels with higher accuracy and quantitative sensitivity than DAB staining. This enhancement in the diagnostic accuracy and sensitivity for ERs using our immunostaining method will improve the prediction of responses to therapies that target ERs and progesterone receptors that are induced by a downstream ER signal. PMID

  18. Projection operator method for biperiodic diffraction gratings with anisotropic/bianisotropic generalizations.

    PubMed

    Johnson, Kenneth C

    2014-08-01

    The "projection operator" method is a variation of the normal-vector method for simulating optical diffraction from biperiodic gratings. A projection operator defined by the normal vector is interpolated over the grating volume rather than interpolating the vector itself. This approach circumvents difficulties associated with sign reversals and discontinuities encountered with the normal-vector method, and it facilitates implementation for general grating geometries. The method is readily extensible to anisotropic and bianisotropic materials. Several numerical examples of the new method are presented, including comparisons to previously published test cases.

  19. An Innovative Method for Dynamic Characterization of Fan FilterUnit Operation.

    SciTech Connect

    Xu, Tengfang

    2006-12-21

    Fan filter units (FFU) are widely used to deliver re-circulated air while providing filtration control of particle concentration in controlled environments such as cleanrooms, minienvironments, and operating rooms in hospitals. The objective of this paper is to document an innovative method for characterizing operation and control of an individual fan filter unit within its operable conditions. Built upon the draft laboratory method previously published [1] , this paper presents an updated method including a testing procedure to characterize dynamic operation of fan filter units, i.e., steady-state operation conditions determined by varied control schemes, airflow rates, and pressure differential across the units. The parameters for dynamic characterization include total electric power demand, total pressure efficiency, airflow rate, pressure differential across fan filter units, and airflow uniformity.

  20. Configurable memory system and method for providing atomic counting operations in a memory device

    DOEpatents

    Bellofatto, Ralph E.; Gara, Alan G.; Giampapa, Mark E.; Ohmacht, Martin

    2010-09-14

    A memory system and method for providing atomic memory-based counter operations to operating systems and applications that make most efficient use of counter-backing memory and virtual and physical address space, while simplifying operating system memory management, and enabling the counter-backing memory to be used for purposes other than counter-backing storage when desired. The encoding and address decoding enabled by the invention provides all this functionality through a combination of software and hardware.

  1. Method for operating a spark-ignition, direct-injection internal combustion engine

    DOEpatents

    Narayanaswamy, Kushal; Koch, Calvin K.; Najt, Paul M.; Szekely, Jr., Gerald A.; Toner, Joel G.

    2015-06-02

    A spark-ignition, direct-injection internal combustion engine is coupled to an exhaust aftertreatment system including a three-way catalytic converter upstream of an NH3-SCR catalyst. A method for operating the engine includes operating the engine in a fuel cutoff mode and coincidentally executing a second fuel injection control scheme upon detecting an engine load that permits operation in the fuel cutoff mode.

  2. Development of rapid, sensitive and non-radioactive tissue-blot diagnostic method for the detection of citrus greening.

    PubMed

    Nageswara-Rao, Madhugiri; Miyata, Shin-Ichi; Ghosh, Dilip; Irey, Mike; Garnsey, Stephen M; Gowda, Siddarame

    2013-01-01

    Citrus huanglongbing (HLB or citrus greening) is one of the most devastating diseases of citrus worldwide. The disease is caused by Gram-negative, phloem-limited α-proteobacterium, 'Candidatus Liberibacter asiaticus', vectored by the psyllid, Diaphorina citri Kuwayama. Citrus plants infected by the HLB bacterium may not show visible symptoms sometimes for years following infection and non-uniform distribution within the tree makes the detection of the pathogen very difficult. Efficient management of HLB disease requires rapid and sensitive detection early in the infection followed by eradication of the source of pathogen and the vector. The polymerase chain reaction (PCR) based method is most commonly employed for screening the infected/suspected HLB plants and psyllids. This is time consuming, cumbersome and not practical for screening large number of samples in the field. To overcome this, we developed a simple, sensitive, non-radioactive, tissue-blot diagnostic method for early detection and screening of HLB disease. Digoxigenin labeled molecular probes specific to 'Ca. L. asiaticus' nucleotide sequences have been developed and used for the detection of the pathogen of the HLB disease. The copy number of the target genes was also assessed using real-time PCR experiments and the optimized real-time PCR protocol allowed positive 'Ca. L. asiaticus' detection in citrus samples infected with 'Ca. L. asiaticus' bacterium.

  3. Tokamak physics experiment: Diagnostic windows study

    SciTech Connect

    Merrigan, M.; Wurden, G.A.

    1995-11-01

    We detail the study of diagnostic windows and window thermal stress remediation in the long-pulse, high-power Tokamak Physics Experiment (TPX) operation. The operating environment of the TPX diagnostic windows is reviewed, thermal loads on the windows estimated, and cooling requirements for the windows considered. Applicable window-cooling technology from other fields is reviewed and its application to the TPX windows considered. Methods for TPX window thermal conditioning are recommended, with some discussion of potential implementation problems provided. Recommendations for further research and development work to ensure performance of windows in the TPX system are presented.

  4. Geostationary satellite positioning by DLR/GSOC operations and management methods

    NASA Technical Reports Server (NTRS)

    Brittinger, Peter

    1994-01-01

    Starting with a short description of the GSOC (German Space Operations Center) and its role within the wider framework of the research institute DLR, this paper provides a review of the geostationary telecommunications satellites positioned by the GSOC. The paper then proceeds to describe the evolution of the operations and management structures and methods which have been effectively used to accomplish these missions.

  5. International recommendation for a comprehensive neuropathologic workup of epilepsy surgery brain tissue: A consensus Task Force report from the ILAE Commission on Diagnostic Methods.

    PubMed

    Blümcke, Ingmar; Aronica, Eleonora; Miyata, Hajime; Sarnat, Harvey B; Thom, Maria; Roessler, Karl; Rydenhag, Bertil; Jehi, Lara; Krsek, Pavel; Wiebe, Samuel; Spreafico, Roberto

    2016-03-01

    Epilepsy surgery is an effective treatment in many patients with drug-resistant focal epilepsies. An early decision for surgical therapy is facilitated by a magnetic resonance imaging (MRI)-visible brain lesion congruent with the electrophysiologically abnormal brain region. Recent advances in the pathologic diagnosis and classification of epileptogenic brain lesions are helpful for clinical correlation, outcome stratification, and patient management. However, application of international consensus classification systems to common epileptic pathologies (e.g., focal cortical dysplasia [FCD] and hippocampal sclerosis [HS]) necessitates standardized protocols for neuropathologic workup of epilepsy surgery specimens. To this end, the Task Force of Neuropathology from the International League Against Epilepsy (ILAE) Commission on Diagnostic Methods developed a consensus standard operational procedure for tissue inspection, distribution, and processing. The aims are to provide a systematic framework for histopathologic workup, meeting minimal standards and maximizing current and future opportunities for morphofunctional correlations and molecular studies for both clinical care and research. Whenever feasible, anatomically intact surgical specimens are desirable to enable systematic analysis in selective hippocampectomies, temporal lobe resections, and lesional or nonlesional neocortical samples. Correct orientation of sample and the sample's relation to neurophysiologically aberrant sites requires good communication between pathology and neurosurgical teams. Systematic tissue sampling of 5-mm slabs along a defined anatomic axis and application of a limited immunohistochemical panel will ensure a reliable differential diagnosis of main pathologies encountered in epilepsy surgery. PMID:26839983

  6. The Rule of Histology in the Diagnosis of Periprosthetic Infection: Specific Granulocyte Counting Methods and New Immunohistologic Staining Techniques may Increase the Diagnostic Value

    PubMed Central

    Boettner, Friedrich; Koehler, Gabriele; Wegner, Alexander; Schmidt-Braekling, Tom; Gosheger, Georg; Goetze, Christian

    2016-01-01

    Objective: The current study investigates the diagnostic accuracy of the criteria described for frozen sections and whether modern leukocyte specific staining techniques including leukocyte peroxidase and Naphtol-AS-D-chloroacetate-esterase will improve the accuracy of the intra-operative histology. Method: 77 patients undergoing revision total hip and knee arthroplasty were included in this retrospective study. Patients were grouped into septic and aseptic based on intraoperative cultures. Tissue samples were analyzed utilizing the Mirra, Feldman, Lonner, Banit and Athanasou criteria. Results: An experienced pathologist had a high specificity (96%), but rather low sensitivity (57%) diagnosing infection. By using the Banit-, Mirra-, or Athanasou-criteria the sensitivity is increased to 0.90. The Feldman- and Lonner-criteria have a lower sensitivity (0.48 and 0.38), however, an increased specificity of 0.96 and 0.98, respectively. The Banit cut off has the highest accuracy (86%). MPOX and NACE staining increased the sensitivity and accuracy up to 100% and 92% respectively. Conclusion: Banit’s cut off is the most accurate histologic criteria to diagnose infection. Modern leukocyte specific staining techniques slightly improve the accuracy. The synovial fluid white blood cell count appears to be the most accurate intraoperative test. PMID:27708741

  7. International recommendation for a comprehensive neuropathologic workup of epilepsy surgery brain tissue: A consensus Task Force report from the ILAE Commission on Diagnostic Methods.

    PubMed

    Blümcke, Ingmar; Aronica, Eleonora; Miyata, Hajime; Sarnat, Harvey B; Thom, Maria; Roessler, Karl; Rydenhag, Bertil; Jehi, Lara; Krsek, Pavel; Wiebe, Samuel; Spreafico, Roberto

    2016-03-01

    Epilepsy surgery is an effective treatment in many patients with drug-resistant focal epilepsies. An early decision for surgical therapy is facilitated by a magnetic resonance imaging (MRI)-visible brain lesion congruent with the electrophysiologically abnormal brain region. Recent advances in the pathologic diagnosis and classification of epileptogenic brain lesions are helpful for clinical correlation, outcome stratification, and patient management. However, application of international consensus classification systems to common epileptic pathologies (e.g., focal cortical dysplasia [FCD] and hippocampal sclerosis [HS]) necessitates standardized protocols for neuropathologic workup of epilepsy surgery specimens. To this end, the Task Force of Neuropathology from the International League Against Epilepsy (ILAE) Commission on Diagnostic Methods developed a consensus standard operational procedure for tissue inspection, distribution, and processing. The aims are to provide a systematic framework for histopathologic workup, meeting minimal standards and maximizing current and future opportunities for morphofunctional correlations and molecular studies for both clinical care and research. Whenever feasible, anatomically intact surgical specimens are desirable to enable systematic analysis in selective hippocampectomies, temporal lobe resections, and lesional or nonlesional neocortical samples. Correct orientation of sample and the sample's relation to neurophysiologically aberrant sites requires good communication between pathology and neurosurgical teams. Systematic tissue sampling of 5-mm slabs along a defined anatomic axis and application of a limited immunohistochemical panel will ensure a reliable differential diagnosis of main pathologies encountered in epilepsy surgery.

  8. Cost-effective methods for designing and operating fiberglass sucker rod strings

    SciTech Connect

    Jacobs, G.H.

    1986-01-01

    This paper describes procedures used by Amoco Production Company in a West Texas district to maximize the life of more than 200 fiberglass rod strings in service at depths between 5000 and 8000 ft. The paper describes rod string design methods, operating practices, and failure analyses for two major manufacturers' rods. Emphasis has been placed on showing procedures used in designing fiberglass rod strings for cost effective installation and for operating so as to minimize the number of rod string failures and, consequently, rod string operating costs. Actual cases histories are used to illustrate the reduction in failure frequency which results from proper rod string design, operating practices, and failure analysis.

  9. Trade study: Liquid hydrogen transportation - Kennedy Space Center. [cost and operational effectivenss of shipping methods.

    NASA Technical Reports Server (NTRS)

    Gray, D. J.

    1978-01-01

    Cryogenic transportation methods for providing liquid hydrogen requirements are examined in support of shuttle transportation system launch operations at Kennedy Space Center, Florida, during the time frames 1982-1991 in terms of cost and operational effectiveness. Transportation methods considered included sixteen different options employing mobile semi-trailer tankers, railcars, barges and combinations of each method. The study concludes that the most effective method of delivering liquid hydrogen from the vendor production facility in New Orleans to Kennedy Space Center includes maximum utilization of existing mobile tankers and railcars supplemented by maximum capacity mobile tankers procured incrementally in accordance with shuttle launch rates actually achieved.

  10. Examination of the operator and compensator tank role in urban wastewater treatment using activated sludge method.

    PubMed

    Mokhtari Azar, Akbar; Ghadirpour Jelogir, Ali; Nabi Bidhendi, Gholam Reza; Zaredar, Narges

    2011-04-01

    No doubt, operator is one of the main fundaments in wastewater treatment plants. By identifying the inadequacies, the operator could be considered as an important key in treatment plant. Several methods are used for wastewater treatment that requires spending a lot of cost. However, all investments of treatment facilities are usable when the expected efficiency of the treatment plant was obtained. Using experienced operator, this goal is more easily accessible. In this research, the wastewater of an urban community contaminated with moderated, diluted and highly concentrated pollution has been treated using surface and deep aeration treatment method. Sampling of these pilots was performed during winter 2008 to summer 2009. The results indicate that all analyzed parameters were eliminated using activated sludge and surface aeration methods. However, in activated sludge and deep aeration methods in combination with suitable function of operator, more pollutants could be eliminated. Hence, existence of operator in wastewater treatment plants is the basic principle to achieve considered efficiency. Wastewater treatment system is not intelligent itself and that is the operator who can organize even an inefficient system by its continuous presence. The converse of this fact is also real. Despite the various units and appropriate design of wastewater treatment plant, without an operator, the studied process cannot be expected highly efficient. In places frequently affected by the shock of organic and hydraulic loads, the compensator tank is important to offset the wastewater treatment process. Finally, in regard to microbial parameters, existence of disinfection unit is very useful. PMID:20571882

  11. Development of a laser cleaning method for the first mirror surface of the charge exchange recombination spectroscopy diagnostics on ITER

    NASA Astrophysics Data System (ADS)

    Kuznetsov, A. P.; Buzinskij, O. I.; Gubsky, K. L.; Nikitina, E. A.; Savchenkov, A. V.; Tarasov, B. A.; Tugarinov, S. N.

    2015-12-01

    A set of optical diagnostics is expected for measuring the plasma characteristics in ITER. Optical elements located inside discharge chambers are exposed to an intense radiation load, sputtering due to collisions with energetic atoms formed in the charge transfer processes, and contamination due to recondensation of materials sputtered from different parts of the construction of the chamber. Removing the films of the sputtered materials from the mirrors with the aid of pulsed laser radiation is an efficient cleaning method enabling recovery of the optical properties of the mirrors. In this work, we studied the efficiency of removal of metal oxide films by pulsed radiation of a fiber laser. Optimization of the laser cleaning conditions was carried out on samples representing metal substrates polished with optical quality with deposition of films on them imitating the chemical composition and conditions expected in ITER. It is shown that, by a proper selection of modes of radiation exposure to the surface with a deposited film, it is feasible to restore the original high reflection characteristics of optical elements.

  12. Review of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography using several endoscopic methods in patients with surgically altered gastrointestinal anatomy

    PubMed Central

    Shimatani, Masaaki; Takaoka, Makoto; Tokuhara, Mitsuo; Miyoshi, Hideaki; Ikeura, Tsukasa; Okazaki, Kazuichi

    2015-01-01

    The endoscopic approach for biliary diseases in patients with surgically altered gastrointestinal anatomy (SAGA) had been generally deemed impractical. However, it was radically made feasible by the introduction of double balloon endoscopy (DBE) that was originally developed for diagnosis and treatments for small-bowel diseases. Followed by the subsequent development of single-balloon endoscopy (SBE) and spiral endoscopy (SE), interventions using several endoscopes for biliary disease in patients with SAGA widely gained an acceptance as a new modality. Many studies have been made on this new technique. Yet, some problems are to be solved. For instance, the mutual unavailability among devices due to different working lengths and channels, and unestablished standardization of procedural techniques can be raised. Additionally, in an attempt to standardize endoscopic procedures, it is important to evaluate biliary cannulating methods by case with existence of papilla or not. A full comprehension of the features of respective scope types is also required. However there are not many papers written as a review. In our manuscript, we would like to evaluate and make a review of the present status of diagnostic and therapeutic endoscopic retrograde cholangiopancreatography applying DBE, SBE and SE for biliary diseases in patients with SAGA for establishment of these modalities as a new technology and further improvement of the scopes and devices. PMID:26078830

  13. Development of a laser cleaning method for the first mirror surface of the charge exchange recombination spectroscopy diagnostics on ITER

    SciTech Connect

    Kuznetsov, A. P.; Buzinskij, O. I.; Gubsky, K. L.; Nikitina, E. A.; Savchenkov, A. V.; Tarasov, B. A.; Tugarinov, S. N.

    2015-12-15

    A set of optical diagnostics is expected for measuring the plasma characteristics in ITER. Optical elements located inside discharge chambers are exposed to an intense radiation load, sputtering due to collisions with energetic atoms formed in the charge transfer processes, and contamination due to recondensation of materials sputtered from different parts of the construction of the chamber. Removing the films of the sputtered materials from the mirrors with the aid of pulsed laser radiation is an efficient cleaning method enabling recovery of the optical properties of the mirrors. In this work, we studied the efficiency of removal of metal oxide films by pulsed radiation of a fiber laser. Optimization of the laser cleaning conditions was carried out on samples representing metal substrates polished with optical quality with deposition of films on them imitating the chemical composition and conditions expected in ITER. It is shown that, by a proper selection of modes of radiation exposure to the surface with a deposited film, it is feasible to restore the original high reflection characteristics of optical elements.

  14. Validation and operational application of a rapid method for rabies antigen detection.

    PubMed

    Saturday, Greg A; King, Robin; Fuhrmann, Leslie

    2009-01-01

    The Veterinary Laboratory Europe (VLE) deployed a direct, rapid immunohistochemical test (DRIT), developed by the Centers for Disease Control and Prevention (CDC), to the US military veterinary units in Iraq and Afghanistan. The test detects rabies virus antigen in fresh and frozen brainstem samples from various animal species. The goal was to conduct surveillance in 2 countries without current rabies diagnostic capabilities and little historical data on rabies prevalence. During the deployment the DRIT was evaluated, and Veterinary Corps officers and technicians were trained to operate the test. Civilian veterinarians from both Iraq and Afghanistan were organized for a lecture forum on rabies, a sample collection lab, and familiarization with the DRIT. Samples collected in Iraq and Afghanistan were tested in the field with the DRIT, and compared to the traditional laboratory standard utilizing direct fluorescent antibody testing at VLE and the CDC with 100% agreement.

  15. Development of a quantitative diagnostic method of estrogen receptor expression levels by immunohistochemistry using organic fluorescent material-assembled nanoparticles

    SciTech Connect

    Gonda, Kohsuke; Miyashita, Minoru; Watanabe, Mika; Takahashi, Yayoi; Goda, Hideki; Okada, Hisatake; Nakano, Yasushi; Tada, Hiroshi; Amari, Masakazu; Ohuchi, Noriaki

    2012-09-28

    quantitatively examine the two methods. The results demonstrated that our nanoparticle staining analyzed a wide range of ER expression levels with higher accuracy and quantitative sensitivity than DAB staining. This enhancement in the diagnostic accuracy and sensitivity for ERs using our immunostaining method will improve the prediction of responses to therapies that target ERs and progesterone receptors that are induced by a downstream ER signal.

  16. Numerical simulations used for a validity check on the laser induced photo-detachment diagnostic method in electronegative plasmas

    SciTech Connect

    Oudini, N.; Taccogna, F.; Aanesland, A.

    2014-06-15

    Laser photo-detachment is used as a method to measure or determine the negative ion density and temperature in electronegative plasmas. In essence, the method consists of producing an electropositive channel (negative ion free region) via pulsed laser photo-detachment within an electronegative plasma bulk. Electrostatic probes placed in this channel measure the change in the electron density. A second pulse might be used to track the negative ion recovery. From this, the negative ion density and temperature can be determined. We study the formation and relaxation of the electropositive channel via a two-dimensional Particle-In-Cell/Mote Carlo collision model. The simulation is mainly carried out in a Hydrogen plasma with an electronegativity of α = 1, with a parametric study for α up to 20. The temporal and spatial evolution of the plasma potential and the electron densities shows the formation of a double layer (DL) confining the photo-detached electrons within the electropositive channel. This DL evolves into two fronts that move in the opposite directions inside and outside of the laser spot region. As a consequence, within the laser spot region, the background and photo-detached electron energy distribution function relaxes/thermalizes via collisionless effects such as Fermi acceleration and Landau damping. Moreover, the simulations show that collisional effects and the DL electric field strength might play a non-negligible role in the negative ion recovery within the laser spot region, leading to a two-temperature negative ion distribution. The latter result might have important effects in the determination of the negative ion density and temperature from laser photo detachment diagnostic.

  17. [Viral respiratory infections in children: new diagnostic methods for early detection. Initial results of a pilot project in Switzerland].

    PubMed

    Schopfer, K; Germann, D; Eggenberger, K; Bächler, A; Wunderli, W

    1986-04-19

    The new methods of rapid viral diagnosis make it possible to specify a number of the most prevalent agents of respiratory tract infections within 24 hours. The techniques are based on the immunological detection of antigens of respiratory syncytial (RSV), adeno, parainfluenza type 1, 2 and 3, as well as of influenza A and B viruses in nasopharyngeal secretions. During a one-year period we have used these methods to evaluate diagnostically 1541 outpatients presenting with upper and lower respiratory tract infections. The patients included babies, infants and children under 16. In about 50% of all sick babies below the age of three months a definite viral infection could be established, and in approximately 30% of infants and children aged up to 4 years. RSV was most frequently observed, accounting for 53.6% of all infections (80% of all babies below the age of 3 months, in whom specified agents could be identified, had RSV infection). The next most frequent pathogens were parainfluenza type 3 (18,8%), influenza A (11,3%) and, finally, adenoviruses (10.2%). The epidemiological and clinical characteristics of these infections are summarized. In addition, the results of these antigen detecting assays have been compared with those of concomitantly conducted virus isolation techniques in cell cultures. This comparative analysis most impressively revealed the time saved by attempting an etiological diagnosis using the antigen detecting system: in only 6% was a specific diagnosis established on the basis of virus isolation, whereas the delay was equal or more than 8 days in 36% of all patients enroled.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3012772

  18. Topics on Test Methods for Space Systems and Operations Safety: Applicability of Experimental Data

    NASA Technical Reports Server (NTRS)

    Hirsch, David B.

    2009-01-01

    This viewgraph presentation reviews topics on test methods for space systems and operations safety through experimentation and analysis. The contents include: 1) Perception of reality through experimentation and analysis; 2) Measurements, methods, and correlations with real life; and 3) Correlating laboratory aerospace materials flammability data with data in spacecraft environments.

  19. Comparison of the Monte Carlo adjoint-weighted and differential operator perturbation methods

    SciTech Connect

    Kiedrowski, Brian C; Brown, Forrest B

    2010-01-01

    Two perturbation theory methodologies are implemented for k-eigenvalue calculations in the continuous-energy Monte Carlo code, MCNP6. A comparison of the accuracy of these techniques, the differential operator and adjoint-weighted methods, is performed numerically and analytically. Typically, the adjoint-weighted method shows better performance over a larger range; however, there are exceptions.

  20. 42 CFR 84.146 - Method of measuring the power and torque required to operate blowers.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...—Apparatus for measuring power required to operate blower. (42 CFR part 84, subpart J, § 84.146) EC01FE91.050 ... 42 Public Health 1 2011-10-01 2011-10-01 false Method of measuring the power and torque required... RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.146 Method of measuring the power and...