Operator adaptation to changes in system reliability under adaptable automation.
Chavaillaz, Alain; Sauer, Juergen
2017-09-01
This experiment examined how operators coped with a change in system reliability between training and testing. Forty participants were trained for 3 h on a complex process control simulation modelling six levels of automation (LOA). In training, participants either experienced a high- (100%) or low-reliability system (50%). The impact of training experience on operator behaviour was examined during a 2.5 h testing session, in which participants either experienced a high- (100%) or low-reliability system (60%). The results showed that most operators did not often switch between LOA. Most chose an LOA that relieved them of most tasks but maintained their decision authority. Training experience did not have a strong impact on the outcome measures (e.g. performance, complacency). Low system reliability led to decreased performance and self-confidence. Furthermore, complacency was observed under high system reliability. Overall, the findings suggest benefits of adaptable automation because it accommodates different operator preferences for LOA. Practitioner Summary: The present research shows that operators can adapt to changes in system reliability between training and testing sessions. Furthermore, it provides evidence that each operator has his/her preferred automation level. Since this preference varies strongly between operators, adaptable automation seems to be suitable to accommodate these large differences.
Angeltveit, Andreas; Paulsen, Gøran; Solberg, Paul A; Raastad, Truls
2016-02-01
Operators in Special Operation Forces (SOF) have a particularly demanding profession where physical and psychological capacities can be challenged to the extremes. The diversity of physical capacities needed depend on the mission. Consequently, tests used to monitor SOF operators' physical fitness should cover a broad range of physical capacities. Whereas tests for strength and aerobic endurance are established, there is no test for specific anaerobic work capacity described in the literature. The purpose of this study was therefore to evaluate the reliability, validity, and to identify performance determinants of a new test developed for testing specific anaerobic work capacity in SOF operators. Nineteen active young students were included in the concurrent validity part of the study. The students performed the evacuation (EVAC) test 3 times and the results were compared for reliability and with performance in the Wingate cycle test, 300-m sprint, and a maximal accumulated oxygen deficit (MAOD) test. In part II of the study, 21 Norwegian Navy Special Operations Command operators conducted the EVAC test, anthropometric measurements, a dual x-ray absorptiometry scan, leg press, isokinetic knee extensions, maximal oxygen uptake test, and countermovement jump (CMJ) test. The EVAC test showed good reliability after 1 familiarization trial (intraclass correlation = 0.89; coefficient of variance = 3.7%). The EVAC test correlated well with the Wingate test (r = -0.68), 300-m sprint time (r = 0.51), and 300-m mean power (W) (r = -0.67). No significant correlation was found with the MAOD test. In part II of the study, height, body mass, lean body mass, isokinetic knee extension torque, maximal oxygen uptake, and maximal power in a CMJ was significantly correlated with performance in the EVAC test. The EVAC test is a reliable and valid test for anaerobic work capacity for SOF operators, and muscle mass, leg strength, and leg power seem to be the most important determinants of performance.
NASA Technical Reports Server (NTRS)
Rosenfeld, John, H; Minnerly, Kenneth, G; Dyson, Christopher, M.
2012-01-01
High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 yr) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described.
Post-Test Analysis of a 10-Year Sodium Heat Pipe Life Test
NASA Technical Reports Server (NTRS)
Rosenfeld, John H.; Locci, Ivan E.; Sanzi, James L.; Hull, David R.; Geng, Steven M.
2011-01-01
High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 years) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described. Lessons learned and future life test plans are also discussed.
NASA Astrophysics Data System (ADS)
Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey
2018-05-01
The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.
Effects of extended lay-off periods on performance and operator trust under adaptable automation.
Chavaillaz, Alain; Wastell, David; Sauer, Jürgen
2016-03-01
Little is known about the long-term effects of system reliability when operators do not use a system during an extended lay-off period. To examine threats to skill maintenance, 28 participants operated twice a simulation of a complex process control system for 2.5 h, with an 8-month retention interval between sessions. Operators were provided with an adaptable support system, which operated at one of the following reliability levels: 60%, 80% or 100%. Results showed that performance, workload, and trust remained stable at the second testing session, but operators lost self-confidence in their system management abilities. Finally, the effects of system reliability observed at the first testing session were largely found again at the second session. The findings overall suggest that adaptable automation may be a promising means to support operators in maintaining their performance at the second testing session. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Chaoen; Chang, Lung-Hai; Chang, Mei-Hsia; Chen, Ling-Jhen; Chung, Fu-Tsai; Lin, Ming-Chyuan; Liu, Zong-Kai; Lo, Chih-Hung; Tsai, Chi-Lin; Yeh, Meng-Shu; Yu, Tsung-Chi
2017-11-01
Excitation of multipacting, enhanced by gas condensation on cold surfaces of the high power input coupler in a SRF module poses the highest challenge for reliable SRF operation under high average RF power. This could prevent the light source SRF module from being operated with a desired high beam current. Off-line long-term reliability tests have been conducted for the newly constructed 500-MHz SRF KEKB type modules at an accelerating RF voltage of 1.6-MV to enable prediction of their operational reliability in the 3-GeV Taiwan Photon Source (TPS), since prediction from mere production performance by conventional horizontal test is presently unreliable. As expected, operational difficulties resulting from multipacting, enhanced by gas condensation, have been identified in the course of long-term reliability test. Our present hypothesis is that gas condensation can be slowed down by preserving the vacuum pressure at the power coupler close to that reached just after its cool down to liquid helium temperatures. This is achievable by reduction of the power coupler out-gassing rate through comprehensive warm aging. Its feasibility and effectiveness has been experimentally verified in a second long term reliability test. Our success opens the possibility to operate the SRF module free of multipacting trouble and opens a new direction to improve the operational performance of next generation SRF modules in light sources with high beam currents.
[Evaluation of the reliability of freight elevator operators].
Gosk, A; Borodulin-Nadzieja, L; Janocha, A; Salomon, E
1991-01-01
The study involved 58 workers employed at winding machines. Their reliability was estimated from the results of psychomotoric test precision, condition of the vegetative nervous system, and from the results of psychological tests. The tests were carried out at the laboratory and at the workplaces, with all distractive factors and functional connection of the work process present. We have found that the reliability of the workers may be affected by a variety of factors. Among the winding machine operators, work monotony can lead to "monotony syndrome". Among the signalists , the appreciation of great responsibility can lead to unpredictable and non-adequate reactions. From both groups, persons displaying a lower-than-average precision were isolated. All those persons demonstrated a reckless attitude and the opinion of their superiors about them was poor. Those persons constitute potential risk for the reliable operation of the discussed team.
Reliability and Maintainability Analysis: A Conceptual Design Model
1972-03-01
Elements For a System I. Research ane Development A. Preliminary design and engineering B. Fabrication of test equipment C. Test operations D...reliability racquiro:wents, little, if any, modu larzation and auto- matic test features would be incorporated in the subsystem design, limited reliability...niaintaina~ility testing and monitoring would be conducted turing dev!qopmcnt, and little Quality Control effort, in the rell ability/’uaintainalility
76 FR 23801 - North American Electric Reliability Corporation; Order Approving Reliability Standard
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-28
... primary control functionality. Nonetheless, until data from drills, exercises and tests can support a... control center becomes inoperable and to conduct reviews and tests, at least annually, to ensure viability... Preparedness and Operations (EOP) Reliability Standard EOP- 008-1 (Loss of Control Center Functionality). The...
Data mining-based coefficient of influence factors optimization of test paper reliability
NASA Astrophysics Data System (ADS)
Xu, Peiyao; Jiang, Huiping; Wei, Jieyao
2018-05-01
Test is a significant part of the teaching process. It demonstrates the final outcome of school teaching through teachers' teaching level and students' scores. The analysis of test paper is a complex operation that has the characteristics of non-linear relation in the length of the paper, time duration and the degree of difficulty. It is therefore difficult to optimize the coefficient of influence factors under different conditions in order to get text papers with clearly higher reliability with general methods [1]. With data mining techniques like Support Vector Regression (SVR) and Genetic Algorithm (GA), we can model the test paper analysis and optimize the coefficient of impact factors for higher reliability. It's easy to find that the combination of SVR and GA can get an effective advance in reliability from the test results. The optimal coefficient of influence factors optimization has a practicability in actual application, and the whole optimizing operation can offer model basis for test paper analysis.
NASA Technical Reports Server (NTRS)
Feldstein, J. F.
1977-01-01
Failure data from 16 commercial spacecraft were analyzed to evaluate failure trends, reliability growth, and effectiveness of tests. It was shown that the test programs were highly effective in ensuring a high level of in-orbit reliability. There was only a single catastrophic problem in 44 years of in-orbit operation on 12 spacecraft. The results also indicate that in-orbit failure rates are highly correlated with unit and systems test failure rates. The data suggest that test effectiveness estimates can be used to guide the content of a test program to ensure that in-orbit reliability goals are achieved.
System reliability analysis through corona testing
NASA Technical Reports Server (NTRS)
Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.
1975-01-01
A corona vacuum test facility for nondestructive testing of power system components was built in the Reliability and Quality Engineering Test Laboratories at the NASA Lewis Research Center. The facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. The facility is being used to test various high-voltage power system components.
System reliability analysis through corona testing
NASA Technical Reports Server (NTRS)
Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.
1975-01-01
In the Reliability and Quality Engineering Test Laboratory at the NASA Lewis Research Center a nondestructive, corona-vacuum test facility for testing power system components was developed using commercially available hardware. The test facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. This facility is being used to test various high voltage power system components.
An Overview of Long Duration Sodium Heat Pipe Tests
NASA Astrophysics Data System (ADS)
Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon
2004-02-01
High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore, Inc. has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 316L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650C to 700C for over 115,000 hours without signs of failure. A second 316L stainless steel heat pipe with a specially-designed Inconel 601 rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600C to 650C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41,000 hours at nearly 700C. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.
An Overview of Long Duration Sodium Heat Pipe Tests
NASA Technical Reports Server (NTRS)
Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon
2004-01-01
High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore International, Inc., has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 3l6L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650 to 700 C for over 115,000 hours without signs of failure. A second 3l6L stainless steel heat pipe with a specially-designed Inconel 60 I rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600 to 650 C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41 ,000 hours at nearly 700 0c. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700 C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability, Detailed design specifications, operating hi story, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...
Systems Issues In Terrestrial Fiber Optic Link Reliability
NASA Astrophysics Data System (ADS)
Spencer, James L.; Lewin, Barry R.; Lee, T. Frank S.
1990-01-01
This paper reviews fiber optic system reliability issues from three different viewpoints - availability, operating environment, and evolving technologies. Present availability objectives for interoffice links and for the distribution loop must be re-examined for applications such as the Synchronous Optical Network (SONET), Fiber-to-the-Home (FTTH), and analog services. The hostile operating environments of emerging applications (such as FTTH) must be carefully considered in system design as well as reliability assessments. Finally, evolving technologies might require the development of new reliability testing strategies.
Component Reliability Testing of Long-Life Sorption Cryocoolers
NASA Technical Reports Server (NTRS)
Bard, S.; Wu, J.; Karlmann, P.; Mirate, C.; Wade, L.
1994-01-01
This paper summarizes ongoing experiments characterizing the ability of critical sorption cryocooler components to achieve highly reliable operation for long-life space missions. Test data obtained over the past several years at JPL are entirely consistent with achieving ten year life for sorption compressors, electrical heaters, container materials, valves, and various sorbent materials suitable for driving 8 to 180 K refrigeration stages. Test results for various compressor systems are reported. Planned future tests necessary to gain a detailed understanding of the sensitivity of cooler performance and component life to operating constraints, design configurations, and fabrication, assembly and handling techniques, are also discussed.
System reliability, performance and trust in adaptable automation.
Chavaillaz, Alain; Wastell, David; Sauer, Jürgen
2016-01-01
The present study examined the effects of reduced system reliability on operator performance and automation management in an adaptable automation environment. 39 operators were randomly assigned to one of three experimental groups: low (60%), medium (80%), and high (100%) reliability of automation support. The support system provided five incremental levels of automation which operators could freely select according to their needs. After 3 h of training on a simulated process control task (AutoCAMS) in which the automation worked infallibly, operator performance and automation management were measured during a 2.5-h testing session. Trust and workload were also assessed through questionnaires. Results showed that although reduced system reliability resulted in lower levels of trust towards automation, there were no corresponding differences in the operators' reliance on automation. While operators showed overall a noteworthy ability to cope with automation failure, there were, however, decrements in diagnostic speed and prospective memory with lower reliability. Copyright © 2015. Published by Elsevier Ltd.
Assuring long-term reliability of concentrator PV systems
NASA Astrophysics Data System (ADS)
McConnell, R.; Garboushian, V.; Brown, J.; Crawford, C.; Darban, K.; Dutra, D.; Geer, S.; Ghassemian, V.; Gordon, R.; Kinsey, G.; Stone, K.; Turner, G.
2009-08-01
Concentrator PV (CPV) systems have attracted significant interest because these systems incorporate the world's highest efficiency solar cells and they are targeting the lowest cost production of solar electricity for the world's utility markets. Because these systems are just entering solar markets, manufacturers and customers need to assure their reliability for many years of operation. There are three general approaches for assuring CPV reliability: 1) field testing and development over many years leading to improved product designs, 2) testing to internationally accepted qualification standards (especially for new products) and 3) extended reliability tests to identify critical weaknesses in a new component or design. Amonix has been a pioneer in all three of these approaches. Amonix has an internal library of field failure data spanning over 15 years that serves as the basis for its seven generations of CPV systems. An Amonix product served as the test CPV module for the development of the world's first qualification standard completed in March 2001. Amonix staff has served on international standards development committees, such as the International Electrotechnical Commission (IEC), in support of developing CPV standards needed in today's rapidly expanding solar markets. Recently Amonix employed extended reliability test procedures to assure reliability of multijunction solar cell operation in its seventh generation high concentration PV system. This paper will discuss how these three approaches have all contributed to assuring reliability of the Amonix systems.
Arcjet starting reliability - A multistart test on hydrogen/nitrogen mixtures
NASA Technical Reports Server (NTRS)
Haag, Thomas W.; Curran, Frank M.
1987-01-01
An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets on board a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hr. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.
Arcjet starting reliability: A multistart test on hydrogen/nitrogen mixtures
NASA Technical Reports Server (NTRS)
Haag, Thomas W.; Curran, Frank M.
1987-01-01
An arcjet starting reliability test was performed to investigate one feasibility issue in the use of arcjets onboard a satellite for north-south stationkeeping. A 1 kW arcjet was run on hydrogen/nitrogen gas mixtures simulating decomposed hydrazine. A pulse width modulated power supply with an integral high voltage starting pulser was used for arc ignition and steady-state operation. The test was performed in four phases in order to determine if starting characteristics changed as a result of long term thruster operation. More than 300 successful starts were accumulated over an operating time of 18 hrs. Overall results indicate that there is a link between starting characteristics and long term thruster operation; however, the large number of starts had no effect on steady-state performance.
Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue
NASA Astrophysics Data System (ADS)
Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang
2018-07-01
Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.
Reliability Issues and Solutions in Flexible Electronics Under Mechanical Fatigue
NASA Astrophysics Data System (ADS)
Yi, Seol-Min; Choi, In-Suk; Kim, Byoung-Joon; Joo, Young-Chang
2018-03-01
Flexible devices are of significant interest due to their potential expansion of the application of smart devices into various fields, such as energy harvesting, biological applications and consumer electronics. Due to the mechanically dynamic operations of flexible electronics, their mechanical reliability must be thoroughly investigated to understand their failure mechanisms and lifetimes. Reliability issue caused by bending fatigue, one of the typical operational limitations of flexible electronics, has been studied using various test methodologies; however, electromechanical evaluations which are essential to assess the reliability of electronic devices for flexible applications had not been investigated because the testing method was not established. By employing the in situ bending fatigue test, we has studied the failure mechanism for various conditions and parameters, such as bending strain, fatigue area, film thickness, and lateral dimensions. Moreover, various methods for improving the bending reliability have been developed based on the failure mechanism. Nanostructures such as holes, pores, wires and composites of nanoparticles and nanotubes have been suggested for better reliability. Flexible devices were also investigated to find the potential failures initiated by complex structures under bending fatigue strain. In this review, the recent advances in test methodology, mechanism studies, and practical applications are introduced. Additionally, perspectives including the future advance to stretchable electronics are discussed based on the current achievements in research.
Reliability of high-power QCW arrays
NASA Astrophysics Data System (ADS)
Feeler, Ryan; Junghans, Jeremy; Remley, Jennifer; Schnurbusch, Don; Stephens, Ed
2010-02-01
Northrop Grumman Cutting Edge Optronics has developed a family of arrays for high-power QCW operation. These arrays are built using CTE-matched heat sinks and hard solder in order to maximize the reliability of the devices. A summary of a recent life test is presented in order to quantify the reliability of QCW arrays and associated laser gain modules. A statistical analysis of the raw lifetime data is presented in order to quantify the data in such a way that is useful for laser system designers. The life tests demonstrate the high level of reliability of these arrays in a number of operating regimes. For single-bar arrays, a MTTF of 19.8 billion shots is predicted. For four-bar samples, a MTTF of 14.6 billion shots is predicted. In addition, data representing a large pump source is analyzed and shown to have an expected lifetime of 13.5 billion shots. This corresponds to an expected operational lifetime of greater than ten thousand hours at repetition rates less than 370 Hz.
Life and Reliability Characteristics of TurboBrayton Coolers
NASA Technical Reports Server (NTRS)
Breedlove, Jeff J.; Zagarola, Mark; Nellis, Greg; Dolan, Frank; Swift, Walt; Gibbon, Judith; Obenschain, Arthur F. (Technical Monitor)
2000-01-01
Wear and internal contaminants are two of the primary factors that influence reliable, long-life operation of turbo-Brayton cryocoolers. This paper describes tests that have been conducted and methods that have been developed for turbo-Brayton components and systems to assure reliable operation. The turbomachines used in these coolers employ self-acting gas bearings to support the miniature high-speed shafts, thus providing vibration-free operation. Because the bearings are self-acting, rubbing contact occurs during initial start-up and shutdown of the machines. Bearings and shafts are designed to endure multiple stop/start cycles without producing particles or surface features that would impair the proper operation of the machines. Test results are presented for a variety of turbomachines used in these systems. The tests document extended operating life and start/stop cycling behavior for machines over a range of time and temperature scales. Contaminants such as moisture and other residual gas impurities can be a source of degraded operation if they freeze out in sufficient quantities to block flow passages or if they mechanically affect the operation of the machines. A post-fabrication bakeout procedure has been successfully used to reduce residual internal contamination to acceptable levels in a closed cycle system. The process was developed during space qualification tests on the NICMOS cryocooler. Moisture levels were sampled over a six-month time interval confirming the effectiveness of the technique. A description of the bakeout procedure is presented.
Developing Reliable Life Support for Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.
Reliability Testing of NASA Piezocomposite Actuators
NASA Technical Reports Server (NTRS)
Wilkie, W.; High, J.; Bockman, J.
2002-01-01
NASA Langley Research Center has developed a low-cost piezocomposite actuator which has application for controlling vibrations in large inflatable smart space structures, space telescopes, and high performance aircraft. Tests show the NASA piezocomposite device is capable of producing large, directional, in-plane strains on the order of 2000 parts-per-million peak-to-peak, with no reduction in free-strain performance to 100 million electrical cycles. This paper describes methods, measurements, and preliminary results from our reliability evaluation of the device under externally applied mechanical loads and at various operational temperatures. Tests performed to date show no net reductions in actuation amplitude while the device was moderately loaded through 10 million electrical cycles. Tests were performed at both room temperature and at the maximum operational temperature of the epoxy resin system used in manufacture of the device. Initial indications are that actuator reliability is excellent, with no actuator failures or large net reduction in actuator performance.
NASA Astrophysics Data System (ADS)
Trachtenberg, I.
How a reliability model might be developed with new data from accelerated stress testing, failure mechanisms, process control monitoring, and test structure evaluations is illustrated. The effects of the acceleration of temperature on operating life is discussed. Test structures that will further accelerate the failure rate are discussed. Corrosion testing is addressed. The uncoated structure is encapsulated in a variety of mold compounds and subjected to pressure-cooker testing.
Time-Tagged Risk/Reliability Assessment Program for Development and Operation of Space System
NASA Astrophysics Data System (ADS)
Kubota, Yuki; Takegahara, Haruki; Aoyagi, Junichiro
We have investigated a new method of risk/reliability assessment for development and operation of space system. It is difficult to evaluate risk of spacecraft, because of long time operation, maintenance free and difficulty of test under the ground condition. Conventional methods are FMECA, FTA, ETA and miscellaneous. These are not enough to assess chronological anomaly and there is a problem to share information during R&D. A new method of risk and reliability assessment, T-TRAP (Time-tagged Risk/Reliability Assessment Program) is proposed as a management tool for the development and operation of space system. T-TRAP consisting of time-resolved Fault Tree and Criticality Analyses, upon occurrence of anomaly in the system, facilitates the responsible personnel to quickly identify the failure cause and decide corrective actions. This paper describes T-TRAP method and its availability.
openECA Platform and Analytics Alpha Test Results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, Russell
The objective of the Open and Extensible Control and Analytics (openECA) Platform for Phasor Data project is to develop an open source software platform that significantly accelerates the production, use, and ongoing development of real-time decision support tools, automated control systems, and off-line planning systems that (1) incorporate high-fidelity synchrophasor data and (2) enhance system reliability while enabling the North American Electric Reliability Corporation (NERC) operating functions of reliability coordinator, transmission operator, and/or balancing authority to be executed more effectively.
Kim, J K; Lim, H M
2015-02-01
The purpose of this study was to translate and culturally adapt the Carpal Tunnel Questionnaire to produce an equivalent Korean version. A total of 53 patients completed the Korean version of the Carpal Tunnel Questionnaire pre-operatively and 3 months after open carpal tunnel release. All 53 also completed the Korean version of the Disabilities of Arm, Shoulder, and Hand questionnaire pre-operatively and 3 months post-operatively. Reliability was measured by determining the test-retest reliability and internal consistency. Test-retest reliability was assessed using intraclass correlation coefficients and paired t-tests, and internal consistency using Cronbach's alpha coefficients. Pearson correlation analysis was carried out on the Korean version of the Carpal Tunnel Questionnaire scores and the Korean version of the Disabilities of Arm, Shoulder, and Hand scores to assess construct validity. Responsiveness was evaluated using effect sizes and standardized response means. The reliability of the Korean version of the Carpal Tunnel Questionnaire was good. The scores in the Korean version of the Disabilities of Arm, Shoulder, and Hand strongly correlated with the scores in the Korean version of the Carpal Tunnel Questionnaire. Standardized response mean and effect size were both large for the Korean version of the Carpal Tunnel Questionnaire. The study shows that the Korean version of the Carpal Tunnel Questionnaire is a reliable, valid and responsive instrument for measuring outcomes in carpal tunnel syndrome. © The Author(s) 2014.
Traveling-wave tube reliability estimates, life tests, and space flight experience
NASA Technical Reports Server (NTRS)
Lalli, V. R.; Speck, C. E.
1977-01-01
Infant mortality, useful life, and wearout phase of twt life are considered. The performance of existing developmental tubes, flight experience, and sequential hardware testing are evaluated. The reliability history of twt's in space applications is documented by considering: (1) the generic parts of the tube in light of the manner in which their design and operation affect the ultimate reliability of the device, (2) the flight experience of medium power tubes, and (3) the available life test data for existing space-qualified twt's in addition to those of high power devices.
R&D of high reliable refrigeration system for superconducting generators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hosoya, T.; Shindo, S.; Yaguchi, H.
1996-12-31
Super-GM carries out R&D of 70 MW class superconducting generators (model machines), refrigeration system and superconducting wires to apply superconducting technology to electric power apparatuses. The helium refrigeration system for keeping field windings of superconducting generator (SCG) in cryogenic environment must meet the requirement of high reliability for uninterrupted long term operation of the SCG. In FY 1992, a high reliable conventional refrigeration system for the model machines was integrated by combining components such as compressor unit, higher temperature cold box and lower temperature cold box which were manufactured utilizing various fundamental technologies developed in early stage of the projectmore » since 1988. Since FY 1993, its performance tests have been carried out. It has been confirmed that its performance was fulfilled the development target of liquefaction capacity of 100 L/h and impurity removal in the helium gas to < 0.1 ppm. Furthermore, its operation method and performance were clarified to all different modes as how to control liquefaction rate and how to supply liquid helium from a dewar to the model machine. In addition, the authors have made performance tests and system performance analysis of oil free screw type and turbo type compressors which greatly improve reliability of conventional refrigeration systems. The operation performance and operational control method of the compressors has been clarified through the tests and analysis.« less
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.
Update on MTTF figures for linear and rotary coolers of Thales Cryogenics
NASA Astrophysics Data System (ADS)
van de Groep, W.; van der Weijden, H.; van Leeuwen, R.; Benschop, T.; Cauquil, J. M.; Griot, R.
2012-06-01
Thales Cryogenics has an extensive background in delivering linear and rotary coolers for military, civil and space programs. During the last years several technical improvements have increased the lifetime of all Thales coolers resulting in significantly higher Mean Time To Failure (MTTF) figures. In this paper not only updated MTTF values for most of the products in our portfolio will be presented but also the methodology used to come to these reliability figures will be explained. The differences between rotary and linear coolers will be highlighted including the different failure modes influencing the lifetime under operational conditions. These updated reliability figures are based on extensive test results for both rotary and linear coolers as well as Weibull analysis, failure mode identifications, various types of lifetime testing and field results of operational coolers. The impact of the cooler selection for typical applications will be outlined. This updated reliability approach will enable an improved tradeoff for cooler selection in applications where MTTF and a correct reliability assessment is key. Improbing on cooler selection and an increased insight in cooler reliability will result in a higher uptime and operability of equipment, less risk on unexpected failures and lower costs of ownership.
Effective core potential calculations on small molecules containing transition metal atoms
NASA Astrophysics Data System (ADS)
Gropen, O.; Wahlgren, U.; Pettersson, L.
1982-04-01
A series of test calculations on diatomic oxides and hydrides of Sc, Ti, Cr, Ni and Zn have been carried out in order to test the reliability of some pseudopotential methods. Several different forms of some pseudopotential operators were used. Only the highest valence orbitals of each atomic symmetry were explicitly included in the calculations. The results indicate that there are problems associated with all the investigated operators particularly for the lighter transition elements. It is suggested that more reliable results may be obtained with pseudopotential methods using smaller cores.
Reliability Quantification of Advanced Stirling Convertor (ASC) Components
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Korovaichuk, Igor; Zampino, Edward
2010-01-01
The Advanced Stirling Convertor, is intended to provide power for an unmanned planetary spacecraft and has an operational life requirement of 17 years. Over this 17 year mission, the ASC must provide power with desired performance and efficiency and require no corrective maintenance. Reliability demonstration testing for the ASC was found to be very limited due to schedule and resource constraints. Reliability demonstration must involve the application of analysis, system and component level testing, and simulation models, taken collectively. Therefore, computer simulation with limited test data verification is a viable approach to assess the reliability of ASC components. This approach is based on physics-of-failure mechanisms and involves the relationship among the design variables based on physics, mechanics, material behavior models, interaction of different components and their respective disciplines such as structures, materials, fluid, thermal, mechanical, electrical, etc. In addition, these models are based on the available test data, which can be updated, and analysis refined as more data and information becomes available. The failure mechanisms and causes of failure are included in the analysis, especially in light of the new information, in order to develop guidelines to improve design reliability and better operating controls to reduce the probability of failure. Quantified reliability assessment based on fundamental physical behavior of components and their relationship with other components has demonstrated itself to be a superior technique to conventional reliability approaches based on utilizing failure rates derived from similar equipment or simply expert judgment.
Construction of a survey to assess workload and fatigue among AMT operators in Mexico.
Hernández Arellano, Juan Luis; Ibarra Mejía, Gabriel; Serratos Pérez, J Nieves; García Alcaraz, Jorge Luis; Brunette, María Julia
2012-01-01
Operators of machinery classified as Advanced Manufacturing Technology (AMT) are exposed to high levels of workload and fatigue. However, only few studies have been conducted on this topic in Hispanic-American countries workers. Several instruments be used to assess workload and fatigue; however, only few of them have been adapted to Spanish language. This paper reports on the development and validity testing of a survey instrument in Spanish, aiming to subjectively assess workload and fatigue among AMT operators in Mexico. After an exhaustive literature review in search of already available measurement instruments, they were adapted for content and later translated into Spanish; a pilot test was conducted to evaluate validity and reliability; afterwards appropriate modifications were made to the testing instruments. Final version of the instrument was applied to a group of 121 operators of CNC lathes. Reliability was analyzed using KMO and Cronbach alpha indices. For the assessment of workload, both NASA-TLX and ISTAS 21 methods were incorporated to the survey instrument. As for fatigue assessment tools, these were SOFI-S, FAS and OFER questionnaires. RESULTS show KMO value and Cronbach alpha above 0.6.Conclusions. The survey instrument as designed, allows the collection of reliable and valid data regarding workload and fatigue among AMT operators in Mexico.
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472
NASA Astrophysics Data System (ADS)
Launch vehicle propulsion system reliability considerations during the design and verification processes are discussed. The tools available for predicting and minimizing anomalies or failure modes are described and objectives for validating advanced launch system propulsion reliability are listed. Methods for ensuring vehicle/propulsion system interface reliability are examined and improvements in the propulsion system development process are suggested to improve reliability in launch operations. Also, possible approaches to streamline the specification and procurement process are given. It is suggested that government and industry should define reliability program requirements and manage production and operations activities in a manner that provides control over reliability drivers. Also, it is recommended that sufficient funds should be invested in design, development, test, and evaluation processes to ensure that reliability is not inappropriately subordinated to other management considerations.
Quasi-CW Laser Diode Bar Life Tests
NASA Technical Reports Server (NTRS)
Stephen, Mark A.; Krainak, Michael A.; Dallas, Joseph L.
1997-01-01
NASA's Goddard Space Flight Center is developing technology for satellite-based, high peak power, LIDAR transmitters requiring 3-5 years of reliable operation. Semi-conductor laser diodes provide high efficiency pumping of solid state lasers with the promise of long-lived, reliable operation. 100-watt quasi- CW laser diode bars have been baselined for the next generation laser altimeters. Multi-billion shot lifetimes are required. The authors have monitored the performance of several diodes for billions of shots and investigated operational modes for improving diode lifetime.
Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Oriti, Salvatore; Wilson, Scott
2011-01-01
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, OH, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hour period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hour period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.
Advanced Stirling Convertor (ASC-E2) Performance Testing at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Oriti, Salvatore; Wilson, Scott
2011-01-01
The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG Project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, four pairs of ASCs capable of operating to 850 C and designated with the model number ASC-E2, were delivered by Sunpower of Athens, Ohio, to GRC in 2010. The ASC-E2s underwent a series of tests that included workmanship vibration testing, performance mapping, and extended operation. Workmanship vibration testing was performed following fabrication of each convertor to verify proper hardware build. Performance mapping consisted of operating each convertor at various conditions representing the range expected during a mission. Included were conditions representing beginning-of-mission (BOM), end-of-mission (EOM), and fueling. This same series of tests was performed by Sunpower prior to ASC-E2 delivery. The data generated during the GRC test were compared to performance before delivery. Extended operation consisted of a 500-hr period of operation with conditions maintained at the BOM point. This was performed to demonstrate steady convertor performance following performance mapping. Following this initial 500-hr period, the ASC-E2s will continue extended operation, controller development and special durability testing, during which the goal is to accumulate tens of thousands of hours of operation. Data collected during extended operation will support reliability analysis. Performance data from these tests is summarized in this paper.
NASA Technical Reports Server (NTRS)
Robinson, E. A.
1973-01-01
Quality, reliability, and design standards for microwave hybrid microcircuits were established. The MSFC Standard 85M03926 for hybrid microcircuits was reviewed and modifications were generated for use with microwave hybrid microcircuits. The results for reliability tests of microwave thin film capacitors, transistors, and microwave circuits are presented. Twenty-two microwave receivers were tested for 13,500 unit hours. The result of 111,121 module burn-in and operating hours for an integrated solid state transceiver module is reported.
2005 8th Annual Systems Engineering Conference. Volume 4, Thursday
2005-10-27
requirements, allocation , and utilization statistics Operations Decisions Acquisition Decisions Resource Management — Integrated Requirements/ Allocation ...Quality Improvement Consultants, Inc. “Automated Software Testing Increases Test Quality and Coverage Resulting in Improved Software Reliability.”, Mr...Steven Ligon, SAIC The Return of Discipline, Ms. Jacqueline Townsend, Air Force Materiel Command Track 4 - Net Centric Operations: Testing Net-Centric
System-wide versus component-specific trust using multiple aids.
Keller, David; Rice, Stephen
2010-01-01
Previous research in operator trust toward automated aids has focused primarily on single aids. The current study focuses on how operator trust is affected by the presence of multiple aids. Two competing theories of multiple-trust are presented. A component-specific trust theory predicts that operators will differentially place their trust in automated aids that vary in reliability. A system-wide trust theory predicts that operators will treat multiple imperfect aids as one "system" and merge their trust across aids despite differences in the aids' reliability. A simulated flight task was used to test these theories, whereby operators performed a pursuit tracking task while concurrently monitoring multiple system gauges that were augmented with perfect or imperfect automated aids. The data revealed that a system-wide trust theory best predicted the data; operators merged their trust across both aids, behaving toward a perfectly reliable aid in the same manner as they did towards unreliable aids.
Emotional-volitional components of operator reliability. [sensorimotor function testing under stress
NASA Technical Reports Server (NTRS)
Mileryan, Y. A.
1975-01-01
Sensorimotor function testing in a tracking task under stressfull working conditions established a psychological characterization for a successful aviation pilot: Motivation significantly increased the reliability and effectiveness of their work. Their acitivities were aimed at suppressing weariness and the feeling of fear caused by the stress factors; they showed patience, endurance, persistence, and a capacity for lengthy volitional efforts.
Sonar Transducer Reliability Improvement Program (STRIP).
1981-04-01
CERAMICS. ... .......................... 31 10. STANDARDIZED TEST PROCEDURE ........ .................... ... 35 11. ACCELERATED LIFE TEST...components, and piece-parts that will meet specified requirements in the operational environment during the entire useful life of the transducer. Standards...C.I. Bohmaun F-3 Reliability & Life Prediction TRI R.I. Smith Specification ,F-4 TR-122 FM4 & Improvements NRL-USRD R.W. Timm 1-5 Metal Matrix
UNIX-based operating systems robustness evaluation
NASA Technical Reports Server (NTRS)
Chang, Yu-Ming
1996-01-01
Robust operating systems are required for reliable computing. Techniques for robustness evaluation of operating systems not only enhance the understanding of the reliability of computer systems, but also provide valuable feed- back to system designers. This thesis presents results from robustness evaluation experiments on five UNIX-based operating systems, which include Digital Equipment's OSF/l, Hewlett Packard's HP-UX, Sun Microsystems' Solaris and SunOS, and Silicon Graphics' IRIX. Three sets of experiments were performed. The methodology for evaluation tested (1) the exception handling mechanism, (2) system resource management, and (3) system capacity under high workload stress. An exception generator was used to evaluate the exception handling mechanism of the operating systems. Results included exit status of the exception generator and the system state. Resource management techniques used by individual operating systems were tested using programs designed to usurp system resources such as physical memory and process slots. Finally, the workload stress testing evaluated the effect of the workload on system performance by running a synthetic workload and recording the response time of local and remote user requests. Moderate to severe performance degradations were observed on the systems under stress.
Petrova, Tatjana; Kavookjian, Jan; Madson, Michael B; Dagley, John; Shannon, David; McDonough, Sharon K
2015-01-01
Motivational interviewing (MI) has demonstrated a significant impact as an intervention strategy for addiction management, change in lifestyle behaviors, and adherence to prescribed medication and other treatments. Key elements to studying MI include training in MI of professionals who will use it, assessment of skills acquisition in trainees, and the use of a validated skills assessment tool. The purpose of this research project was to develop a psychometrically valid and reliable tool that has been designed to assess MI skills competence in health care provider trainees. The goal was to develop an assessment tool that would evaluate the acquisition and use of specific MI skills and principles, as well as the quality of the patient-provider therapeutic alliance in brief health care encounters. To address this purpose, specific steps were followed, beginning with a literature review. This review contributed to the development of relevant conceptual and operational definitions, selecting a scaling technique and response format, and methods for analyzing validity and reliability. Internal consistency reliability was established on 88 video recorded interactions. The inter-rater and test-retest reliability were established using randomly selected 18 from the 88 interactions. The assessment tool Motivational Interviewing Skills for Health Care Encounters (MISHCE) and a manual for use of the tool were developed. Validity and reliability of MISHCE were examined. Face and content validity were supported with well-defined conceptual and operational definitions and feedback from an expert panel. Reliability was established through internal consistency, inter-rater reliability, and test-retest reliability. The overall internal consistency reliability (Cronbach's alpha) for all fifteen items was 0.75. MISHCE demonstrated good inter-rater reliability and good to excellent test-retest reliability. MISHCE assesses the health provider's level of knowledge and skills in brief disease management encounters. MISHCE also evaluates quality of the patient-provider therapeutic alliance, i.e., the "flow" of the interaction. Copyright © 2015 Elsevier Inc. All rights reserved.
Reliability analysis of instrument design of noninvasive bone marrow disease detector
NASA Astrophysics Data System (ADS)
Su, Yu; Li, Ting; Sun, Yunlong
2016-02-01
Bone marrow is an important hematopoietic organ, and bone marrow lesions (BMLs) may cause a variety of complications with high death rate and short survival time. Early detection and follow up care are particularly important. But the current diagnosis methods rely on bone marrow biopsy/puncture, with significant limitations such as invasion, complex operation, high risk, and discontinuous. It is highly in need of a non-invasive, safe, easily operated, and continuous monitoring technology. So we proposed to design a device aimed for detecting bone marrow lesions, which was based on near infrared spectrum technology. Then we fully tested its reliabilities, including the sensitivity, specificity, signal-to-noise ratio (SNR), stability, and etc. Here, we reported this sequence of reliability test experiments, the experimental results, and the following data analysis. This instrument was shown to be very sensitive, with distinguishable concentration less than 0.002 and with good linearity, stability and high SNR. Finally, these reliability-test data supported the promising clinical diagnosis and surgery guidance of our novel instrument in detection of BMLs.
Integrating Formal Methods and Testing 2002
NASA Technical Reports Server (NTRS)
Cukic, Bojan
2002-01-01
Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.
NASA Astrophysics Data System (ADS)
Treichel, Todd H.
Commercial space designers are required to manage space flight designs in accordance with parts selections made from qualified parts listings approved by Department of Defense and NASA agencies for reliability and safety. The research problem was a government and private aerospace industry problem involving how LEDs cannot replace existing fluorescent lighting in manned space flight vehicles until such technology meets DOD and NASA requirements for reliability and safety, and effects on astronaut cognition and health. The purpose of this quantitative experimental study was to determine to what extent commercial LEDs can suitably meet NASA requirements for manufacturer reliability, color reliability, robustness to environmental test requirements, and degradation effects from operational power, while providing comfortable ambient light free of eyestrain to astronauts in lieu of current fluorescent lighting. A fractional factorial experiment tested white and blue LEDs for NASA required space flight environmental stress testing and applied operating current. The second phase of the study used a randomized block design, to test human factor effects of LEDs and a qualified ISS fluorescent for retinal fatigue and eye strain. Eighteen human subjects were recruited from university student members of the American Institute of Aeronautics and Astronautics. Findings for Phase 1 testing showed that commercial LEDs met all DOD and NASA requirements for manufacturer reliability, color reliability, robustness to environmental requirements, and degradation effects from operational power. Findings showed statistical significance for LED color and operational power variables but degraded light output levels did not fall below the industry recognized <70%. Findings from Phase 2 human factors testing showed no statistically significant evidence that the NASA approved ISS fluorescent lights or blue or white LEDs caused fatigue, eye strain and/or headache, when study participants perform detailed tasks of reading and assembling mechanical parts for an extended period of two uninterrupted hours. However, human subjects self-reported that blue LEDs provided the most white light and the favored light source over the white LED and the ISS fluorescent as a sole artificial light source for space travel. According to NASA standards, findings from this study indicate that LEDs meet criteria for the NASA TRL 7 rating, as study findings showed that commercial LED manufacturers passed the rigorous testing standards of suitability for space flight environments and human factor effects. Recommendations for future research include further testing for space flight using the basis of this study for replication, but reduce study limitations by 1) testing human subjects exposure to LEDs in a simulated space capsule environment over several days, and 2) installing and testing LEDs in space modules being tested for human spaceflight.
Reliability considerations of a fuel cell backup power system for telecom applications
NASA Astrophysics Data System (ADS)
Serincan, Mustafa Fazil
2016-03-01
A commercial fuel cell backup power unit is tested in real life operating conditions at a base station of a Turkish telecom operator. The fuel cell system responds to 256 of 260 electric power outages successfully, providing the required power to the base station. Reliability of the fuel cell backup power unit is found to be 98.5% at the system level. On the other hand, a qualitative reliability analysis at the component level is carried out. Implications of the power management algorithm on reliability is discussed. Moreover, integration of the backup power unit to the base station ecosystem is reviewed in the context of reliability. Impact of inverter design on the stability of the output power is outlined. Significant current harmonics are encountered when a generic inverter is used. However, ripples are attenuated significantly when a custom design inverter is used. Further, fault conditions are considered for real world case studies such as running out of hydrogen, a malfunction in the system, or an unprecedented operating scheme. Some design guidelines are suggested for hybridization of the backup power unit for an uninterrupted operation.
Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2005)
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...
Tracer-Test Planning Using the Efficient Hydrologic Tracer-Test Design (Ehtd) Program (2003)
Hydrological tracer testing is the most reliable diagnostic technique available for establishing flow trajectories and hydrologic connections and for determining basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test ...
Advanced Stirling Convertor Testing at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Wilson, Scott D.; Poriti, Sal
2010-01-01
The NASA Glenn Research Center (GRC) has been testing high-efficiency free-piston Stirling convertors for potential use in radioisotope power systems (RPSs) since 1999. The current effort is in support of the Advanced Stirling Radioisotope Generator (ASRG), which is being developed by the U.S. Department of Energy (DOE), Lockheed Martin Space Systems Company (LMSSC), Sunpower, Inc., and the NASA GRC. This generator would use two high-efficiency Advanced Stirling Convertors (ASCs) to convert thermal energy from a radioisotope heat source into electricity. As reliability is paramount to a RPS capable of providing spacecraft power for potential multi-year missions, GRC provides direct technology support to the ASRG flight project in the areas of reliability, convertor and generator testing, high-temperature materials, structures, modeling and analysis, organics, structural dynamics, electromagnetic interference (EMI), and permanent magnets to reduce risk and enhance reliability of the convertor as this technology transitions toward flight status. Convertor and generator testing is carried out in short- and long-duration tests designed to characterize convertor performance when subjected to environments intended to simulate launch and space conditions. Long duration testing is intended to baseline performance and observe any performance degradation over the life of the test. Testing involves developing support hardware that enables 24/7 unattended operation and data collection. GRC currently has 14 Stirling convertors under unattended extended operation testing, including two operating in the ASRG Engineering Unit (ASRG-EU). Test data and high-temperature support hardware are discussed for ongoing and future ASC tests with emphasis on the ASC-E and ASC-E2.
NASA Astrophysics Data System (ADS)
Snaith, Henry J.; Hacke, Peter
2018-06-01
Photovoltaic modules are expected to operate in the field for more than 25 years, so reliability assessment is critical for the commercialization of new photovoltaic technologies. In early development stages, understanding and addressing the device degradation mechanisms are the priorities. However, any technology targeting large-scale deployment must eventually pass industry-standard qualification tests and undergo reliability testing to validate the module lifetime. In this Perspective, we review the methodologies used to assess the reliability of established photovoltaics technologies and to develop standardized qualification tests. We present the stress factors and stress levels for degradation mechanisms currently identified in pre-commercial perovskite devices, along with engineering concepts for mitigation of those degradation modes. Recommendations for complete and transparent reporting of stability tests are given, to facilitate future inter-laboratory comparisons and to further the understanding of field-relevant degradation mechanisms, which will benefit the development of accelerated stress tests.
NASA Technical Reports Server (NTRS)
Tamayo, Tak Chai
1987-01-01
Quality of software not only is vital to the successful operation of the space station, it is also an important factor in establishing testing requirements, time needed for software verification and integration as well as launching schedules for the space station. Defense of management decisions can be greatly strengthened by combining engineering judgments with statistical analysis. Unlike hardware, software has the characteristics of no wearout and costly redundancies, thus making traditional statistical analysis not suitable in evaluating reliability of software. A statistical model was developed to provide a representation of the number as well as types of failures occur during software testing and verification. From this model, quantitative measure of software reliability based on failure history during testing are derived. Criteria to terminate testing based on reliability objectives and methods to estimate the expected number of fixings required are also presented.
49 CFR 195.428 - Overpressure safety devices and overfill protection systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... months, but at least twice each calendar year, inspect and test each pressure limiting device, relief... reliability of operation for the service in which it is used. (b) In the case of relief valves on pressure breakout tanks containing highly volatile liquids, each operator shall test each valve at intervals not...
An approach to operating system testing
NASA Technical Reports Server (NTRS)
Sum, R. N., Jr.; Campbell, R. H.; Kubitz, W. J.
1984-01-01
To ensure the reliability and performance of a new system, it must be verified or validated in some manner. Currently, testing is the only resonable technique available for doing this. Part of this testing process is the high level system test. System testing is considered with respect to operating systems and in particular UNIX. This consideration results in the development and presentation of a good method for performing the system test. The method includes derivations from the system specifications and ideas for management of the system testing project. Results of applying the method to the IBM System/9000 XENIX operating system test and the development of a UNIX test suite are presented.
Operating Experience and Reliability Improvements on the 5 kW CW Klystron at Jefferson Lab
NASA Astrophysics Data System (ADS)
Nelson, R.; Holben, S.
1997-05-01
With substantial operating hours on the RF system, considerable information on reliability of the 5 kW CW klystrons has been obtained. High early failure rates led to examination of the operating conditions and failure modes. Internal ceramic contamination caused premature failure of gun potting material and ultimate tube demise through arcing or ceramic fracture. A planned course of repotting and reconditioning of approximately 300 klystrons, plus careful attention to operating conditions and periodic analysis of operational data, has substantially reduced the failure rate. It is anticipated that implementation of planned supplemental monitoring systems for the klystrons will allow most catastrophic failures to be avoided. By predicting end of life, tubes can be changed out before they fail, thus minimizing unplanned downtime. Initial tests have also been conducted on this same klystron operated at higher voltages with resultant higher output power. The outcome of these tests will provide information to be considered for future upgrades to the accelerator.
DOT National Transportation Integrated Search
2014-01-01
The objective of this project was to develop system designs for programs to monitor travel time reliability and to prepare a guidebook that practitioners and others can use to design, build, operate, and maintain such systems. Generally, such travel ...
Pilot testing of SHRP 2 reliability data and analytical products: Minnesota. [supporting datasets
DOT National Transportation Integrated Search
2014-01-01
The objective of this project was to develop system designs for programs to monitor travel time reliability and to prepare a guidebook that practitioners and others can use to design, build, operate, and maintain such systems. Generally, such travel ...
Photomultiplier tube reliability study for the HEAO program
NASA Technical Reports Server (NTRS)
Richardson, C.
1974-01-01
Results concerning the research on photomultiplier tubes required for the HEAO program are reported. The general specifications are discussed for providing a series of tests for helping the operational reliability of its application, and for permitting comparison of performance of similar types, from various manufacturers.
Design and Development of the Space Shuttle Tail Service Masts
NASA Technical Reports Server (NTRS)
Dandage, S. R.; Herman, N. A.; Godfrey, S. E.; Uda, R. T.
1977-01-01
The successful launch of a space shuttle vehicle depends on the proper operation of two tail service masts (TSMs). Reliable TSM operation is assured through a comprehensive design, development, and testing program. The results of the concept verification test (CVT) and the resulting impact on prototype TSM design are presented. The design criteria are outlined, and the proposed prototype TSM tests are described.
Role of failure-mechanism identification in accelerated testing
NASA Technical Reports Server (NTRS)
Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.
1993-01-01
Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.
Foster, J D; Miskovic, D; Allison, A S; Conti, J A; Ockrim, J; Cooper, E J; Hanna, G B; Francis, N K
2016-06-01
Laparoscopic rectal resection is technically challenging, with outcomes dependent upon technical performance. No robust objective assessment tool exists for laparoscopic rectal resection surgery. This study aimed to investigate the application of the objective clinical human reliability analysis (OCHRA) technique for assessing technical performance of laparoscopic rectal surgery and explore the validity and reliability of this technique. Laparoscopic rectal cancer resection operations were described in the format of a hierarchical task analysis. Potential technical errors were defined. The OCHRA technique was used to identify technical errors enacted in videos of twenty consecutive laparoscopic rectal cancer resection operations from a single site. The procedural task, spatial location, and circumstances of all identified errors were logged. Clinical validity was assessed through correlation with clinical outcomes; reliability was assessed by test-retest. A total of 335 execution errors identified, with a median 15 per operation. More errors were observed during pelvic tasks compared with abdominal tasks (p < 0.001). Within the pelvis, more errors were observed during dissection on the right side than the left (p = 0.03). Test-retest confirmed reliability (r = 0.97, p < 0.001). A significant correlation was observed between error frequency and mesorectal specimen quality (r s = 0.52, p = 0.02) and with blood loss (r s = 0.609, p = 0.004). OCHRA offers a valid and reliable method for evaluating technical performance of laparoscopic rectal surgery.
Reliability modelling and analysis of thermal MEMS
NASA Astrophysics Data System (ADS)
Muratet, Sylvaine; Lavu, Srikanth; Fourniols, Jean-Yves; Bell, George; Desmulliez, Marc P. Y.
2006-04-01
This paper presents a MEMS reliability study methodology based on the novel concept of 'virtual prototyping'. This methodology can be used for the development of reliable sensors or actuators and also to characterize their behaviour in specific use conditions and applications. The methodology is demonstrated on the U-shaped micro electro thermal actuator used as test vehicle. To demonstrate this approach, a 'virtual prototype' has been developed with the modeling tools MatLab and VHDL-AMS. A best practice FMEA (Failure Mode and Effect Analysis) is applied on the thermal MEMS to investigate and assess the failure mechanisms. Reliability study is performed by injecting the identified defaults into the 'virtual prototype'. The reliability characterization methodology predicts the evolution of the behavior of these MEMS as a function of the number of cycles of operation and specific operational conditions.
Statistical modeling of software reliability
NASA Technical Reports Server (NTRS)
Miller, Douglas R.
1992-01-01
This working paper discusses the statistical simulation part of a controlled software development experiment being conducted under the direction of the System Validation Methods Branch, Information Systems Division, NASA Langley Research Center. The experiment uses guidance and control software (GCS) aboard a fictitious planetary landing spacecraft: real-time control software operating on a transient mission. Software execution is simulated to study the statistical aspects of reliability and other failure characteristics of the software during development, testing, and random usage. Quantification of software reliability is a major goal. Various reliability concepts are discussed. Experiments are described for performing simulations and collecting appropriate simulated software performance and failure data. This data is then used to make statistical inferences about the quality of the software development and verification processes as well as inferences about the reliability of software versions and reliability growth under random testing and debugging.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Design Verification and Periodic Testing of Vital System Automation § 61.40-1 General. (a) All automatically or... tests and inspections to evaluate the operation and reliability of controls, alarms, safety features...
Cygnus Performance in Subcritical Experiments
DOE Office of Scientific and Technical Information (OSTI.GOV)
G. Corrow, M. Hansen, D. Henderson, S. Lutz, C. Mitton, et al.
2008-02-01
The Cygnus Dual Beam Radiographic Facility consists of two identical radiographic sources with the following specifications: 4-rad dose at 1 m, 1-mm spot size, 50-ns pulse length, 2.25-MeV endpoint energy. The facility is located in an underground tunnel complex at the Nevada Test Site. Here SubCritical Experiments (SCEs) are performed to study the dynamic properties of plutonium. The Cygnus sources were developed as a primary diagnostic for these tests. Since SCEs are single-shot, high-value events - reliability and reproducibility are key issues. Enhanced reliability involves minimization of failure modes through design, inspection, and testing. Many unique hardware and operational featuresmore » were incorporated into Cygnus to insure reliability. Enhanced reproducibility involves normalization of shot-to-shot output also through design, inspection, and testing. The first SCE to utilize Cygnus, Armando, was executed on May 25, 2004. A year later, April - May 2005, calibrations using a plutonium step wedge were performed. The results from this series were used for more precise interpretation of the Armando data. In the period February - May 2007 Cygnus was fielded on Thermos, which is a series of small-sample plutonium shots using a one-dimensional geometry. Pulsed power research generally dictates frequent change in hardware configuration. Conversely, SCE applications have typically required constant machine settings. Therefore, while operating during the past four years we have accumulated a large database for evaluation of machine performance under highly consistent operating conditions. Through analysis of this database Cygnus reliability and reproducibility on Armando, Step Wedge, and Thermos is presented.« less
Suggested Operating Procedures for Aquifer Pumping Tests
This document is intended as a primer, describing the process for the design and performance of an “aquifer test” (how to obtain reliable data from a pumping test) to obtain accurate estimates of aquifer parameters.
The Application of Voltage Transformer Simulator in Electrical Test Training
NASA Astrophysics Data System (ADS)
Li, Nan; Zhang, Jun; Chai, Ziqi; Wang, Jingpeng; Yang, Baowei
2018-02-01
The voltage transformer test is an important means to monitor its operating state. The accuracy and reliability of the test data is directly related to the test skill level of the operator. However, the risk of test instruments damage, equipment being tested damage and electric shock in operator is caused by improper operation when training the transformer test. In this paper, a simulation device of voltage transformer is set up, and a simulation model is built for the most common 500kV capacitor voltage transformer (CVT), the simulation model can realize several test items of CVT by combing with teaching guidance platform, simulation instrument, complete set of system software and auxiliary equipment in Changchun. Many successful applications show that the simulation device has good practical value and wide application prospect.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Design... tests and inspections to evaluate the operation and reliability of controls, alarms, safety features... designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Design... tests and inspections to evaluate the operation and reliability of controls, alarms, safety features... designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Design... tests and inspections to evaluate the operation and reliability of controls, alarms, safety features... designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PERIODIC TESTS AND INSPECTIONS Design... tests and inspections to evaluate the operation and reliability of controls, alarms, safety features... designated by the owner of the vessel shall conduct all tests and the Design Verification and Periodic Safety...
NASA Astrophysics Data System (ADS)
Filis, Avishai; Pundak, Nachman; Barak, Moshe; Porat, Ze'ev; Jaeger, Mordechai
2011-06-01
The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and decreased integrated system Life Cycle (ILS) cost. In order to meet this need RICOR has developed a new rotary Stirling cryocooler, model K508N, intended to double the K508's operating MTTF achieving 20,000 operating MTTF hours. The K508N employs RICOR's latest mechanical design technologies such as optimized bearings and greases, bearings preloading, advanced seals, laser welded cold finger and robust design structure with increased natural frequency compared to the K508 model. The cooler enhanced MTTF was demonstrated by a Validation and Verification (V&V) plan comprising analytical means and a comparative accelerated life test between the standard K508 and the K508N models. Particularly, point estimate and confidence interval for the MTTF improvement factor where calculated periodically during and after the test. The (V&V) effort revealed that the K508N meets its MTTF design goal. The paper will focus on the technical and engineering aspects of the new design. In addition it will discuss the market needs and expectations, investigate the reliability data of the present reference K508 model; and report the accelerate life test data and the statistical analysis methodology as well as its underlying assumptions and results.
NASA Technical Reports Server (NTRS)
DiBlasi, Angelo G.
1992-01-01
A preliminary development plan for an integrated propulsion module (IPM) is described. The IPM, similar to the Space Transportation Main engine (STME) engine, is applicable to the Advanced Launch System (ALS) baseline vehicle. The same STME development program ground rules and time schedule were assumed for the IPM. However, the unique advantages of testing an integrated engine element, in terms of reduced number of hardware and number of system and reliability tests, compared to single standalone engine and MPTA, are highlighted. The potential ability of the IPM to meet the ALS program goals for robustness, operability and reliability is emphasized.
Feasibility of Bluetooth Data as a Surrogate Measure of Vehicle Operations
DOT National Transportation Integrated Search
2012-10-01
This research was designed as proof-of-concept study to investigate how Bluetooth data loggers can be used to collect vehicle : operational data over traditional vehicle counting methods. The reliability test included mapping areas for five antenna o...
Reliability analysis and utilization of PEMs in space application
NASA Astrophysics Data System (ADS)
Jiang, Xiujie; Wang, Zhihua; Sun, Huixian; Chen, Xiaomin; Zhao, Tianlin; Yu, Guanghua; Zhou, Changyi
2009-11-01
More and more plastic encapsulated microcircuits (PEMs) are used in space missions to achieve high performance. Since PEMs are designed for use in terrestrial operating conditions, the successful usage of PEMs in space harsh environment is closely related to reliability issues, which should be considered firstly. However, there is no ready-made methodology for PEMs in space applications. This paper discusses the reliability for the usage of PEMs in space. This reliability analysis can be divided into five categories: radiation test, radiation hardness, screening test, reliability calculation and reliability assessment. One case study is also presented to illuminate the details of the process, in which a PEM part is used in a joint space program Double-Star Project between the European Space Agency (ESA) and China. The influence of environmental constrains including radiation, humidity, temperature and mechanics on the PEM part has been considered. Both Double-Star Project satellites are still running well in space now.
Extended Operation of Stirling Convertors at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Oriti, Salvatore, M.
2012-01-01
NASA Glenn Research Center (GRC) has been supporting development of free-piston Stirling conversion technology for spaceflight electrical power generation since 1999. GRC has also been supporting the development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance data for the Advanced Stirling Convertor (ASC). The Thermal Energy Conversion branch at GRC is conducting extended operation of several free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) on multiple units to build a life and reliability database. Currently, GRC is operating 18 convertors. This hardware set includes Technology Demonstration Convertors (TDCs) from Infinia Corporation, of which one pair (TDCs #13 and #14) has accumulated over 60,000 hr (6.8 years) of operation. Also under test are various Sunpower, Inc. convertors that were fabricated during the ASC development activity, including ASC-0, ASC-E (including those in the ASRG engineering unit), and ASC-E2. The ASC-E2s also completed, or are in progress of completing workmanship vibration testing, performance mapping, and extended operation. Two ASC-E2 units will also be used for durability testing, during which components will be stressed to levels above nominal mission usage. Extended operation data analyses from these tests are covered in this paper.
Firefighters' communication transceiver test plan
NASA Astrophysics Data System (ADS)
Wallace, R. J.
1984-05-01
The requirements for the operational testing of the firefighters communication transceiver were identified. The major concerns centered around the integrity and reliability of the firefighter/microphone interface. The major concern about the radio hardware was that it be intrinsically safe in hazardous atmospheres and that the system not interfere with the fit or facial seal of self-contained breathing apparatus (SCBA). The greatest concern for operational testing purposes as the reliability and clarity of the line of communication between the firefighter and those on the fireground with whom he must maintain contact. A desire to test any units developed in both training exercises and in real responses to hazardous material incidents was expressed. It is felt that a VOX-microphone built into the SCBA facemask gives the best performance. A voice-pickup product device which combines a bone conduction microphone and a speaker into a single ear mounted unit is examined.
Firefighters' communication transceiver test plan
NASA Technical Reports Server (NTRS)
Wallace, R. J.
1984-01-01
The requirements for the operational testing of the firefighters communication transceiver were identified. The major concerns centered around the integrity and reliability of the firefighter/microphone interface. The major concern about the radio hardware was that it be intrinsically safe in hazardous atmospheres and that the system not interfere with the fit or facial seal of self-contained breathing apparatus (SCBA). The greatest concern for operational testing purposes as the reliability and clarity of the line of communication between the firefighter and those on the fireground with whom he must maintain contact. A desire to test any units developed in both training exercises and in real responses to hazardous material incidents was expressed. It is felt that a VOX-microphone built into the SCBA facemask gives the best performance. A voice-pickup product device which combines a bone conduction microphone and a speaker into a single ear mounted unit is examined.
Electrical termination techniques
NASA Technical Reports Server (NTRS)
Oakey, W. E.; Schleicher, R. R.
1976-01-01
A technical review of high reliability electrical terminations for electronic equipment was made. Seven techniques were selected from this review for further investigation, experimental work, and preliminary testing. From the preliminary test results, four techniques were selected for final testing and evaluation. These four were: (1) induction soldering, (2) wire wrap, (3) percussive arc welding, and (4) resistance welding. Of these four, induction soldering was selected as the best technique in terms of minimizing operator errors, controlling temperature and time, minimizing joint contamination, and ultimately producing a reliable, uniform, and reusable electrical termination.
Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.
Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung
2018-01-01
Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.
Smart Sensor Demonstration Payload
NASA Technical Reports Server (NTRS)
Schmalzel, John; Bracey, Andrew; Rawls, Stephen; Morris, Jon; Turowski, Mark; Franzl, Richard; Figueroa, Fernando
2010-01-01
Sensors are a critical element to any monitoring, control, and evaluation processes such as those needed to support ground based testing for rocket engine test. Sensor applications involve tens to thousands of sensors; their reliable performance is critical to achieving overall system goals. Many figures of merit are used to describe and evaluate sensor characteristics; for example, sensitivity and linearity. In addition, sensor selection must satisfy many trade-offs among system engineering (SE) requirements to best integrate sensors into complex systems [1]. These SE trades include the familiar constraints of power, signal conditioning, cabling, reliability, and mass, and now include considerations such as spectrum allocation and interference for wireless sensors. Our group at NASA s John C. Stennis Space Center (SSC) works in the broad area of integrated systems health management (ISHM). Core ISHM technologies include smart and intelligent sensors, anomaly detection, root cause analysis, prognosis, and interfaces to operators and other system elements [2]. Sensor technologies are the base fabric that feed data and health information to higher layers. Cost-effective operation of the complement of test stands benefits from technologies and methodologies that contribute to reductions in labor costs, improvements in efficiency, reductions in turn-around times, improved reliability, and other measures. ISHM is an active area of development at SSC because it offers the potential to achieve many of those operational goals [3-5].
Bringing the CMS distributed computing system into scalable operations
NASA Astrophysics Data System (ADS)
Belforte, S.; Fanfani, A.; Fisk, I.; Flix, J.; Hernández, J. M.; Kress, T.; Letts, J.; Magini, N.; Miccio, V.; Sciabà, A.
2010-04-01
Establishing efficient and scalable operations of the CMS distributed computing system critically relies on the proper integration, commissioning and scale testing of the data and workload management tools, the various computing workflows and the underlying computing infrastructure, located at more than 50 computing centres worldwide and interconnected by the Worldwide LHC Computing Grid. Computing challenges periodically undertaken by CMS in the past years with increasing scale and complexity have revealed the need for a sustained effort on computing integration and commissioning activities. The Processing and Data Access (PADA) Task Force was established at the beginning of 2008 within the CMS Computing Program with the mandate of validating the infrastructure for organized processing and user analysis including the sites and the workload and data management tools, validating the distributed production system by performing functionality, reliability and scale tests, helping sites to commission, configure and optimize the networking and storage through scale testing data transfers and data processing, and improving the efficiency of accessing data across the CMS computing system from global transfers to local access. This contribution reports on the tools and procedures developed by CMS for computing commissioning and scale testing as well as the improvements accomplished towards efficient, reliable and scalable computing operations. The activities include the development and operation of load generators for job submission and data transfers with the aim of stressing the experiment and Grid data management and workload management systems, site commissioning procedures and tools to monitor and improve site availability and reliability, as well as activities targeted to the commissioning of the distributed production, user analysis and monitoring systems.
Kang, Qing; Chan, Raymond C K; Li, Xiaoping; Arcelus, Jon; Yue, Ling; Huang, Jiabin; Gu, Lian; Fan, Qing; Zhang, Haiyin; Xiao, Zeping; Chen, Jue
2017-11-01
The study aimed to investigate the reliability and validity of the Chinese version of the eating attitudes test (EAT-26) among female adolescents and young adults in Mainland China. This scale was administered to 396 female eating disorder patients and 406 noneating disorder healthy controls, in addition 35 healthy controls completed a retest after a 4-week intervals. Tests for reliability, convergent validity and receiver operating characteristic analysis were performed to detect the psychometric properties. The EAT-26 demonstrated good internal consistency (Cronbach's alpha = 0.822-0.922), test-retest reliability (interclass correlation coefficient = 0.817) and convergent validity(r = 0.450-0.750). The receiver operating characteristic analysis showed that the cut-off 14 for anorexia nervosa and 15 for bulimia nervosa represented good compromises with approximate sensitivity (0.66-0.68) and specificity (0.85-0.86). Our findings provided evidence that the Chinese version of the EAT-26 was a psychometrically reliable and valid self-rating instrument for identifying people suffering from an eating disorder in Mainland China. A clinical cut-off range between 14 and 15 could be used, but caution should be exercised because of the low sensitivity of the tool. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association. Copyright © 2017 John Wiley & Sons, Ltd and Eating Disorders Association.
NASA Astrophysics Data System (ADS)
Panteleev, A. A.; Bobinkin, V. V.; Larionov, S. Yu.; Ryabchikov, B. E.; Smirnov, V. B.; Shapovalov, D. A.
2017-10-01
When designing large-scale water-treatment plants based on reverse-osmosis systems, it is proposed to conduct experimental-industrial or pilot tests for validated simulation of the operation of the equipment. It is shown that such tests allow establishing efficient operating conditions and characteristics of the plant under design. It is proposed to conduct pilot tests of the reverse-osmosis systems on pilot membrane plants (PMPs) and test membrane plants (TMPs). The results of a comparative experimental study of pilot and test membrane plants are exemplified by simulating the operating parameters of the membrane elements of an industrial plant. It is concluded that the reliability of the data obtained on the TMP may not be sufficient to design industrial water-treatment plants, while the PMPs are capable of providing reliable data that can be used for full-scale simulation of the operation of industrial reverse-osmosis systems. The test membrane plants allow simulation of the operating conditions of individual industrial plant systems; therefore, potential areas of their application are shown. A method for numerical calculation and experimental determination of the true selectivity and the salt passage are proposed. An expression has been derived that describes the functional dependence between the observed and true salt passage. The results of the experiments conducted on a test membrane plant to determine the true value of the salt passage of a reverse-osmosis membrane are exemplified by magnesium sulfate solution at different initial operating parameters. It is shown that the initial content of a particular solution component has a significant effect on the change in the true salt passage of the membrane.
Robust hard-solder packaging of conduction cooled laser diode bars
NASA Astrophysics Data System (ADS)
Schleuning, David; Griffin, Mike; James, Phillip; McNulty, John; Mendoza, Dan; Morales, John; Nabors, David; Peters, Mike; Zhou, Hailong; Reed, Murray
2007-02-01
We present the reliability of high-power laser diodes utilizing hard solder (AuSn) on a conduction-cooled package (HCCP). We present results of 50 W hard-pulse operation at 8xx nm and demonstrate a reliability of MTTF > 27 khrs (90% CL), which is an order of magnitude improvement over traditional packaging. We also present results at 9xx nm with a reliability of MTTF >17 khrs (90% CL) at 75 W. We discuss finite element analysis (FEA) modeling and time dependent temperature measurements combined with experimental life-test data to quantify true hard-pulse operation. We also discuss FEA and measured stress profiles across laser bars comparing soft and hard solder packaging.
Testing and checkout experiences in the National Transonic Facility since becoming operational
NASA Technical Reports Server (NTRS)
Bruce, W. E., Jr.; Gloss, B. B.; Mckinney, L. W.
1988-01-01
The U.S. National Transonic Facility, constructed by NASA to meet the national needs for High Reynolds Number Testing, has been operational in a checkout and test mode since the operational readiness review (ORR) in late 1984. During this time, there have been problems centered around the effect of large temperature excursions on the mechanical movement of large components, the reliable performance of instrumentation systems, and an unexpected moisture problem with dry insulation. The more significant efforts since the ORR are reviewed and NTF status concerning hardware, instrumentation and process controls systems, operating constraints imposed by the cryogenic environment, and data quality and process controls is summarized.
Battery cycling and calendar aging: year one testing results.
DOT National Transportation Integrated Search
2016-07-01
This report is meant to provide an update on the ongoing battery testing performed by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV batte...
DOT National Transportation Integrated Search
1998-08-01
This report describes the DIRECT field test which was designed to evaluate the user benefits, institutional issues, and technical issues of en-route driver advisory and traveler information services. Focus was on testing and evaluating the voice-base...
Digital electronic engine control history
NASA Technical Reports Server (NTRS)
Putnam, T. W.
1984-01-01
Full authority digital electronic engine controls (DEECs) were studied, developed, and ground tested because of projected benefits in operability, improved performance, reduced maintenance, improved reliability, and lower life cycle costs. The issues of operability and improved performance, however, are assessed in a flight test program. The DEEC on a F100 engine in an F-15 aircraft was demonstrated and evaluated. The events leading to the flight test program are chronicled and important management and technical results are identified.
FY12 End of Year Report for NEPP DDR2 Reliability
NASA Technical Reports Server (NTRS)
Guertin, Steven M.
2013-01-01
This document reports the status of the NASA Electronic Parts and Packaging (NEPP) Double Data Rate 2 (DDR2) Reliability effort for FY2012. The task expanded the focus of evaluating reliability effects targeted for device examination. FY11 work highlighted the need to test many more parts and to examine more operating conditions, in order to provide useful recommendations for NASA users of these devices. This year's efforts focused on development of test capabilities, particularly focusing on those that can be used to determine overall lot quality and identify outlier devices, and test methods that can be employed on components for flight use. Flight acceptance of components potentially includes considerable time for up-screening (though this time may not currently be used for much reliability testing). Manufacturers are much more knowledgeable about the relevant reliability mechanisms for each of their devices. We are not in a position to know what the appropriate reliability tests are for any given device, so although reliability testing could be focused for a given device, we are forced to perform a large campaign of reliability tests to identify devices with degraded reliability. With the available up-screening time for NASA parts, it is possible to run many device performance studies. This includes verification of basic datasheet characteristics. Furthermore, it is possible to perform significant pattern sensitivity studies. By doing these studies we can establish higher reliability of flight components. In order to develop these approaches, it is necessary to develop test capability that can identify reliability outliers. To do this we must test many devices to ensure outliers are in the sample, and we must develop characterization capability to measure many different parameters. For FY12 we increased capability for reliability characterization and sample size. We increased sample size this year by moving from loose devices to dual inline memory modules (DIMMs) with an approximate reduction of 20 to 50 times in terms of per device under test (DUT) cost. By increasing sample size we have improved our ability to characterize devices that may be considered reliability outliers. This report provides an update on the effort to improve DDR2 testing capability. Although focused on DDR2, the methods being used can be extended to DDR and DDR3 with relative ease.
49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility
Code of Federal Regulations, 2010 CFR
2010-10-01
.... Because the operator will not become familiar with the detailed design of all new bus models that are tested, tests to determine the time and skill required to remove and reinstall an engine, a transmission... feasible to conduct statistical reliability tests. The detected bus failures, repair time, and the actions...
49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility
Code of Federal Regulations, 2011 CFR
2011-10-01
.... Because the operator will not become familiar with the detailed design of all new bus models that are tested, tests to determine the time and skill required to remove and reinstall an engine, a transmission... feasible to conduct statistical reliability tests. The detected bus failures, repair time, and the actions...
49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility
Code of Federal Regulations, 2013 CFR
2013-10-01
.... Because the operator will not become familiar with the detailed design of all new bus models that are tested, tests to determine the time and skill required to remove and reinstall an engine, a transmission... feasible to conduct statistical reliability tests. The detected bus failures, repair time, and the actions...
Design, Development, Testing, and Evaluation: Human Factors Engineering
NASA Technical Reports Server (NTRS)
Adelstein, Bernard; Hobbs, Alan; OHara, John; Null, Cynthia
2006-01-01
While human-system interaction occurs in all phases of system development and operation, this chapter on Human Factors in the DDT&E for Reliable Spacecraft Systems is restricted to the elements that involve "direct contact" with spacecraft systems. Such interactions will encompass all phases of human activity during the design, fabrication, testing, operation, and maintenance phases of the spacecraft lifespan. This section will therefore consider practices that would accommodate and promote effective, safe, reliable, and robust human interaction with spacecraft systems. By restricting this chapter to what the team terms "direct contact" with the spacecraft, "remote" factors not directly involved in the development and operation of the vehicle, such as management and organizational issues, have been purposely excluded. However, the design of vehicle elements that enable and promote ground control activities such as monitoring, feedback, correction and reversal (override) of on-board human and automation process are considered as per NPR8705.2A, Section 3.3.
Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Link, H.; Keller, J.; Guo, Y.
2013-04-01
Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE)more » through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.« less
Chapter 3: Photovoltaic Module Stability and Reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jordan, Dirk; Kurtz, Sarah
2017-01-01
Profits realized from investment in photovoltaic will benefit from decades of reliable operation. Service life prediction through accelerated tests is only possible if indoor tests duplicate power loss and failure modes observed in fielded systems. Therefore, detailing and quantifying power loss and failure modes is imperative. In the first section, we examine recent trends in degradation rates, the gradual power loss observed for different technologies, climates and other significant factors. In the second section, we provide a summary of the most commonly observed failure modes in fielded systems.
Use of Very Weak Radiation Sources to Determine Aircraft Runway Position
NASA Technical Reports Server (NTRS)
Drinkwater, Fred J., III; Kibort, Bernard R.
1965-01-01
Various methods of providing runway information in the cockpit during the take-off and landing roll have been proposed. The most reliable method has been to use runway distance markers when visible. Flight tests were used to evaluate the feasibility of using weak radio-active sources to trigger a runway distance counter in the cockpit. The results of these tests indicate that a weak radioactive source would provide a reliable signal by which this indicator could be operated.
Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowl...
21 CFR 606.100 - Standard operating procedures.
Code of Federal Regulations, 2013 CFR
2013-04-01
... components from a donor who later tests reactive for evidence of human immunodeficiency virus (HIV) infection... establishment is made aware of other reliable test results or information indicating evidence of HIV or HCV... consignees of the results of the HIV or HCV testing performed on the donors of such blood and blood...
21 CFR 606.100 - Standard operating procedures.
Code of Federal Regulations, 2014 CFR
2014-04-01
... components from a donor who later tests reactive for evidence of human immunodeficiency virus (HIV) infection... establishment is made aware of other reliable test results or information indicating evidence of HIV or HCV... consignees of the results of the HIV or HCV testing performed on the donors of such blood and blood...
21 CFR 606.100 - Standard operating procedures.
Code of Federal Regulations, 2011 CFR
2011-04-01
... components from a donor who later tests reactive for evidence of human immunodeficiency virus (HIV) infection... establishment is made aware of other reliable test results or information indicating evidence of HIV or HCV... consignees of the results of the HIV or HCV testing performed on the donors of such blood and blood...
21 CFR 606.100 - Standard operating procedures.
Code of Federal Regulations, 2012 CFR
2012-04-01
... components from a donor who later tests reactive for evidence of human immunodeficiency virus (HIV) infection... establishment is made aware of other reliable test results or information indicating evidence of HIV or HCV... consignees of the results of the HIV or HCV testing performed on the donors of such blood and blood...
A Manual Control Test for the Detection and Deterrence of Impaired Drivers
NASA Technical Reports Server (NTRS)
Stein, A. C.; Allen, R. W.; Jex, H. R.
1984-01-01
A brief manual control test and a decision strategy were developed, laboratory tested, and field validated which provide a means for detecting human operator impairment from alcohol or other drugs. The test requires the operator to stabilize progressively unstable controlled element dynamics. Control theory and experimental data verify that the human operator's control ability on this task is constrained by basic cybernetic characteristics, and that task performance is reliably affected by impairment effects on these characteristics. Assessment of human operator control ability is determined by a statistically based decision strategy. The operator is allowed several chances to exceed a preset pass criterion. Procedures are described for setting the pass criterion based on individual ability and a desired unimpaired failure rate. These procedures were field tested with apparatus installed in automobiles that were designed to discourage drunk drivers from operating their vehicles. This test program demonstrated that the control task and detection strategy could be applied in a practical setting to screen human operators for impairment in their basic cybernetic skills.
The Development of a Practical and Reliable Assessment Measure for Atopic Dermatitis (ADAM).
ERIC Educational Resources Information Center
Charman, Denise; Varigos, George; Horne, David J. de L.; Oberklaid, Frank
1999-01-01
A study was conducted in Australia to develop a reliable, valid, and practical measure of atopic dermatitis. The test development process and validity evaluation with two doctors and 51 patients are discussed. Results suggest that operational definitions of the scales need to be defined more clearly. The measure satisfies assumptions for a partial…
Development of an Extreme High Temperature n-type Ohmic Contact to Silicon Carbide
NASA Technical Reports Server (NTRS)
Evans, Laura J.; Okojie, Robert S.; Lukco, Dorothy
2011-01-01
We report on the initial demonstration of a tungsten-nickel (75:25 at. %) ohmic contact to silicon carbide (SiC) that performed for up to fifteen hours of heat treatment in argon at 1000 C. The transfer length method (TLM) test structure was used to evaluate the contacts. Samples showed consistent ohmic behavior with specific contact resistance values averaging 5 x 10-4 -cm2. The development of this contact metallization should allow silicon carbide devices to operate more reliably at the present maximum operating temperature of 600 C while potentially extending operations to 1000 C. Introduction Silicon Carbide (SiC) is widely recognized as one of the materials of choice for high temperature, harsh environment sensors and electronics due to its ability to survive and continue normal operation in such environments [1]. Sensors and electronics in SiC have been developed that are capable of operating at temperatures of 600 oC. However operating these devices at the upper reliability temperature threshold increases the potential for early degradation. Therefore, it is important to raise the reliability temperature ceiling higher, which would assure increased device reliability when operated at nominal temperature. There are also instances that require devices to operate and survive for prolonged periods of time above 600 oC [2, 3]. This is specifically needed in the area of hypersonic flight where robust sensors are needed to monitor vehicle performance at temperature greater than 1000 C, as well as for use in the thermomechanical characterization of high temperature materials (e.g. ceramic matrix composites). While SiC alone can withstand these temperatures, a major challenge is to develop reliable electrical contacts to the device itself in order to facilitate signal extraction
Method of Testing and Predicting Failures of Electronic Mechanical Systems
NASA Technical Reports Server (NTRS)
Iverson, David L.; Patterson-Hine, Frances A.
1996-01-01
A method employing a knowledge base of human expertise comprising a reliability model analysis implemented for diagnostic routines is disclosed. The reliability analysis comprises digraph models that determine target events created by hardware failures human actions, and other factors affecting the system operation. The reliability analysis contains a wealth of human expertise information that is used to build automatic diagnostic routines and which provides a knowledge base that can be used to solve other artificial intelligence problems.
NASA Technical Reports Server (NTRS)
Caplin, R. S.; Royer, E. R.
1978-01-01
Attempts are made to provide a total design of a Microbial Load Monitor (MLM) system flight engineering model. Activities include assembly and testing of Sample Receiving and Card Loading Devices (SRCLDs), operator related software, and testing of biological samples in the MLM. Progress was made in assembling SRCLDs with minimal leaks and which operate reliably in the Sample Loading System. Seven operator commands are used to control various aspects of the MLM such as calibrating and reading the incubating reading head, setting the clock and reading time, and status of Card. Testing of the instrument, both in hardware and biologically, was performed. Hardware testing concentrated on SRCLDs. Biological testing covered 66 clinical and seeded samples. Tentative thresholds were set and media performance listed.
Otis, Colombe; Gervais, Julie; Guillot, Martin; Gervais, Julie-Anne; Gauvin, Dominique; Péthel, Catherine; Authier, Simon; Dansereau, Marc-André; Sarret, Philippe; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Beaudry, Francis; Troncy, Eric
2016-06-23
Lack of validity in osteoarthritis pain models and assessment methods is suspected. Our goal was to 1) assess the repeatability and reproducibility of measurement and the influence of environment, and acclimatization, to different pain assessment outcomes in normal rats, and 2) test the concurrent validity of the most reliable methods in relation to the expression of different spinal neuropeptides in a chemical model of osteoarthritic pain. Repeatability and inter-rater reliability of reflexive nociceptive mechanical thresholds, spontaneous static weight-bearing, treadmill, rotarod, and operant place escape/avoidance paradigm (PEAP) were assessed by the intraclass correlation coefficient (ICC). The most reliable acclimatization protocol was determined by comparing coefficients of variation. In a pilot comparative study, the sensitivity and responsiveness to treatment of the most reliable methods were tested in the monosodium iodoacetate (MIA) model over 21 days. Two MIA (2 mg) groups (including one lidocaine treatment group) and one sham group (0.9 % saline) received an intra-articular (50 μL) injection. No effect of environment (observer, inverted circadian cycle, or exercise) was observed; all tested methods except mechanical sensitivity (ICC <0.3), offered good repeatability (ICC ≥0.7). The most reliable acclimatization protocol included five assessments over two weeks. MIA-related osteoarthritic change in pain was demonstrated with static weight-bearing, punctate tactile allodynia evaluation, treadmill exercise and operant PEAP, the latter being the most responsive to analgesic intra-articular lidocaine. Substance P and calcitonin gene-related peptide were higher in MIA groups compared to naive (adjusted P (adj-P) = 0.016) or sham-treated (adj-P = 0.029) rats. Repeated post-MIA lidocaine injection resulted in 34 times lower downregulation for spinal substance P compared to MIA alone (adj-P = 0.029), with a concomitant increase of 17 % in time spent on the PEAP dark side (indicative of increased comfort). This study of normal rats and rats with pain established the most reliable and sensitive pain assessment methods and an optimized acclimatization protocol. Operant PEAP testing was more responsive to lidocaine analgesia than other tests used, while neuropeptide spinal concentration is an objective quantification method attractive to support and validate different centralized pain functional assessment methods.
7 CFR 1730.21 - Inspections and tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
... reliability and security of the electric power grid, cause significant risk to the safety and health of the... AGRICULTURE ELECTRIC SYSTEM OPERATIONS AND MAINTENANCE Operations and Maintenance Requirements § 1730.21... parts of its electric system, annually exercise its ERP, and maintain records of such inspections and...
Inter- and intra-observer reliability of clinical movement-control tests for marines
2012-01-01
Background Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel. Methods This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed an in-vivo observation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model. Results Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain. Conclusions Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain. PMID:23273285
Leddy, Abigail L; Crowner, Beth E; Earhart, Gammon M
2011-01-01
Gait impairments, balance impairments, and falls are prevalent in individuals with Parkinson disease (PD). Although the Berg Balance Scale (BBS) can be considered the reference standard for the determination of fall risk, it has a noted ceiling effect. Development of ceiling-free measures that can assess balance and are good at discriminating "fallers" from "nonfallers" is needed. The purpose of this study was to compare the Functional Gait Assessment (FGA) and the Balance Evaluation Systems Test (BESTest) with the BBS among individuals with PD and evaluate the tests' reliability, validity, and discriminatory sensitivity and specificity for fallers versus nonfallers. This was an observational study of community-dwelling individuals with idiopathic PD. The BBS, FGA, and BESTest were administered to 80 individuals with PD. Interrater reliability (n=15) was assessed by 3 raters. Test-retest reliability was based on 2 tests of participants (n=24), 2 weeks apart. Intraclass correlation coefficients (2,1) were used to calculate reliability, and Spearman correlation coefficients were used to assess validity. Cutoff points, sensitivity, and specificity were based on receiver operating characteristic plots. Test-retest reliability was .80 for the BBS, .91 for the FGA, and .88 for the BESTest. Interrater reliability was greater than .93 for all 3 tests. The FGA and BESTest were correlated with the BBS (r=.78 and r=.87, respectively). Cutoff scores to identify fallers were 47/56 for the BBS, 15/30 for the FGA, and 69% for the BESTest. The overall accuracy (area under the curve) for the BBS, FGA, and BESTest was .79, .80, and .85, respectively. Fall reports were retrospective. Both the FGA and the BESTest have reliability and validity for assessing balance in individuals with PD. The BESTest is most sensitive for identifying fallers.
The 1988 Goddard Space Flight Center Battery Workshop
NASA Technical Reports Server (NTRS)
Yi, Thomas Y. (Editor)
1993-01-01
This document contains the proceedings of the 21st annual Battery Workshop held at Goddard Space Flight Center, Greenbelt, Maryland on November 1-3, 1988. The Workshop attendees included manufacturers, users, and government representatives interested in the latest developments in battery technology as they relate to high reliability operations and aerospace use. The subjects covered included battery testing methodologies and criteria, life testing of nickel-cadmium cells, testing and operation of nickel-hydrogen batteries in low earth orbit, and nickel-hydrogen technology issues and concerns.
Galileo attitude and articulation control subsystem closed loop testing
NASA Technical Reports Server (NTRS)
Lembeck, M. F.; Pignatano, N. D.
1983-01-01
In order to ensure the reliable operation of the Attitude and Articulation Control Subsystem (AACS) which will guide the Galileo spacecraft on its two and one-half year journey to Jupiter, the AACS is being rigorously tested. The primary objectives of the test program are the verification of the AACS's form, fit, and function, especially with regard to subsystem external interfaces and the functional operation of the flight software. Attention is presently given to the Galileo Closed Loop Test System, which simulates the dynamic and 'visual' flight environment for AACS components in the laboratory.
Hollow cathode heater development for the Space Station plasma contactor
NASA Technical Reports Server (NTRS)
Soulas, George C.
1993-01-01
A hollow cathode-based plasma contactor has been selected for use on the Space Station. During the operation of the plasma contactor, the hollow cathode heater will endure approximately 12000 thermal cycles. Since a hollow cathode heater failure would result in a plasma contactor failure, a hollow cathode heater development program was established to produce a reliable heater design. The development program includes the heater design, process documents for both heater fabrication and assembly, and heater testing. The heater design was a modification of a sheathed ion thruster cathode heater. Three heaters have been tested to date using direct current power supplies. Performance testing was conducted to determine input current and power requirements for achieving activation and ignition temperatures, single unit operational repeatability, and unit-to-unit operational repeatability. Comparisons of performance testing data at the ignition input current level for the three heaters show the unit-to-unit repeatability of input power and tube temperature near the cathode tip to be within 3.5 W and 44 degrees C, respectively. Cyclic testing was then conducted to evaluate reliability under thermal cycling. The first heater, although damaged during assembly, completed 5985 ignition cycles before failing. Two additional heaters were subsequently fabricated and have completed 3178 cycles to date in an on-going test.
The development and test of a long-life, high reliability solar array drive actuator
NASA Technical Reports Server (NTRS)
Kirkpatrick, D. L.
1973-01-01
To meet the life and reliability requirements of five to ten year space missions, a new solar array drive mechanism for 3-axis stabilized vehicles has been developed and is undergoing life testing. The drive employs a redundant lubrication system to increase its reliability. An overrunning clutch mechanism is used to permit block redundant application of two or more drives to a common array drive shaft. Two prototype actuator and clutch assemblies, in continuous vacuum life test under load at 10 to the minus 8th power torr for more than sixteen months, have each accumulated more than 34,000 output revolutions without anomaly, the equivalent of more than seven years of operation in a 1000 km orbit or nearly ninety-five years at synchronous altitude.
Catanuto, Giuseppe; Taher, Wafa; Rocco, Nicola; Catalano, Francesca; Allegra, Dario; Milotta, Filippo Luigi Maria; Stanco, Filippo; Gallo, Giovanni; Nava, Maurizio Bruno
2018-03-20
Breast shape is defined utilizing mainly qualitative assessment (full, flat, ptotic) or estimates, such as volume or distances between reference points, that cannot describe it reliably. We will quantitatively describe breast shape with two parameters derived from a statistical methodology denominated principal component analysis (PCA). We created a heterogeneous dataset of breast shapes acquired with a commercial infrared 3-dimensional scanner on which PCA was performed. We plotted on a Cartesian plane the two highest values of PCA for each breast (principal components 1 and 2). Testing of the methodology on a preoperative and postoperative surgical case and test-retest was performed by two operators. The first two principal components derived from PCA are able to characterize the shape of the breast included in the dataset. The test-retest demonstrated that different operators are able to obtain very similar values of PCA. The system is also able to identify major changes in the preoperative and postoperative stages of a two-stage reconstruction. Even minor changes were correctly detected by the system. This methodology can reliably describe the shape of a breast. An expert operator and a newly trained operator can reach similar results in a test/re-testing validation. Once developed and after further validation, this methodology could be employed as a good tool for outcome evaluation, auditing, and benchmarking.
The Essay Scoring and Scorer Reliability in TOEFL CBT.
ERIC Educational Resources Information Center
Lee, Yong-Won
An essay test is now an integral part of the computer based Test of English as a Foreign Language (TOEFL-CBT). This paper provides a brief overview of the current TOEFL-CBT essay test, describes the operational procedures for essay scoring, including the Online Scoring Network (OSN) of the Educational Testing Service (ETS), and discusses major…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patton, A.D.; Ayoub, A.K.; Singh, C.
1982-07-01
This report describes the structure and operation of prototype computer programs developed for a Monte Carlo simulation model, GENESIS, and for two analytical models, OPCON and OPPLAN. It includes input data requirements and sample test cases.
NASA Technical Reports Server (NTRS)
1993-01-01
The Marshall Space Flight Center is responsible for the development and management of advanced launch vehicle propulsion systems, including the Space Shuttle Main Engine (SSME), which is presently operational, and the Space Transportation Main Engine (STME) under development. The SSME's provide high performance within stringent constraints on size, weight, and reliability. Based on operational experience, continuous design improvement is in progress to enhance system durability and reliability. Specialized data analysis and interpretation is required in support of SSME and advanced propulsion system diagnostic evaluations. Comprehensive evaluation of the dynamic measurements obtained from test and flight operations is necessary to provide timely assessment of the vibrational characteristics indicating the operational status of turbomachinery and other critical engine components. Efficient performance of this effort is critical due to the significant impact of dynamic evaluation results on ground test and launch schedules, and requires direct familiarity with SSME and derivative systems, test data acquisition, and diagnostic software. Detailed analysis and evaluation of dynamic measurements obtained during SSME and advanced system ground test and flight operations was performed including analytical/statistical assessment of component dynamic behavior, and the development and implementation of analytical/statistical models to efficiently define nominal component dynamic characteristics, detect anomalous behavior, and assess machinery operational condition. In addition, the SSME and J-2 data will be applied to develop vibroacoustic environments for advanced propulsion system components, as required. This study will provide timely assessment of engine component operational status, identify probable causes of malfunction, and indicate feasible engineering solutions. This contract will be performed through accomplishment of negotiated task orders.
Air STAR Beyond Visual Range UAS Description and Preliminary Test Results
NASA Technical Reports Server (NTRS)
Cunningham, Kevin; Cox, David E.; Foster, John V.; Riddick, Stephen E.; Laughter, Sean A.
2016-01-01
The NASA Airborne Subscale Transport Aircraft Research Unmanned Aerial System project's capabilities were expanded by updating the system design and concept of operations. The new remotely piloted airplane system design was flight tested to assess integrity and operational readiness of the design to perform flight research. The purpose of the system design is to improve aviation safety by providing a capability to validate, in high-risk conditions, technologies to prevent airplane loss of control. Two principal design requirements were to provide a high degree of reliability and that the new design provide a significant increase in test volume (relative to operations using the previous design). The motivation for increased test volume is to improve test efficiency and allow new test capabilities that were not possible with the previous design and concept of operations. Three successful test flights were conducted from runway 4-22 at NASA Goddard Space Flight Center's Wallops Flight Facility.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... Reliability Operating Limits; System Restoration Reliability Standards AGENCY: Federal Energy Regulatory... data necessary to analyze and monitor Interconnection Reliability Operating Limits (IROL) within its... Interconnection Reliability Operating Limits, Order No. 748, 134 FERC ] 61,213 (2011). \\2\\ The term ``Wide-Area...
Photovoltaic module reliability improvement through application testing and failure analysis
NASA Technical Reports Server (NTRS)
Dumas, L. N.; Shumka, A.
1982-01-01
During the first four years of the U.S. Department of Energy (DOE) National Photovoltatic Program, the Jet Propulsion Laboratory Low-Cost Solar Array (LSA) Project purchased about 400 kW of photovoltaic modules for test and experiments. In order to identify, report, and analyze test and operational problems with the Block Procurement modules, a problem/failure reporting and analysis system was implemented by the LSA Project with the main purpose of providing manufacturers with feedback from test and field experience needed for the improvement of product performance and reliability. A description of the more significant types of failures is presented, taking into account interconnects, cracked cells, dielectric breakdown, delamination, and corrosion. Current design practices and reliability evaluations are also discussed. The conducted evaluation indicates that current module designs incorporate damage-resistant and fault-tolerant features which address field failure mechanisms observed to date.
Cognitive functioning after subthalamic nucleotomy for refractory Parkinson's disease
McCarter, R.; Walton, N.; Rowan, A.; Gill, S.; Palomo, M.
2000-01-01
OBJECTIVE—To evaluate whether subthalamic nucleotomy produces adverse cognitive effects in patients with Parkinson's disease. METHOD—Twelve patients with Parkinson's disease underwent stereotactic surgery to the subthalamic nucleus. Presurgical and postsurgical neuropsychological assessment of attention, memory, executive function, language, and verbal intellect were undertaken with a battery of tests designed to minimise potential contamination of cognitive effects by motor symptoms. RESULTS—There was no statistically significant difference in the cognitive tests results after operation for the group as a whole. Reliable change indexes were generated for the cognitive tests. Reliable change postoperatively was found on specific tests of verbal memory, attention, and planning. Left sided operations were associated with greater incidence of deterioration postsurgery. CONCLUSIONS—Preliminary data on the first reported cognitive changes after subthalamic nucleotomy suggested few adverse cognitive effects of the surgery although discrete neuropsychological changes were seen in some patients. These effects were consistent with current theories on the cognitive functions of the basal ganglia. PMID:10864605
Testing to Characterize the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward; Schreiber, Jeffrey
2010-01-01
The Advanced Stirling Radioisotope Generator (ASRG), a high efficiency generator, is being considered for space missions. Lockheed Martin designed and fabricated an engineering unit (EU), the ASRG EU, under contract to the Department of Energy. This unit is currently undergoing extended operation testing at the NASA Glenn Research Center to generate performance data and validate life and reliability predictions for the generator and the Stirling convertors. It has also undergone performance tests to characterize generator operation while varying control parameters and system inputs. This paper summarizes and explains test results in the context of designing operating strategies for the generator during a space mission and notes expected differences between the EU performance and future generators.
NASA Technical Reports Server (NTRS)
Ferlita, F.
1989-01-01
The Advanced Launch Systems (ALS) Advanced Development Oxidizer Turbopump Program has designed, fabricated and demonstrated a low cost, highly reliable oxidizer turbopump for the Space Transportation Engine that minimizes the recurring cost for the ALS engines. Pratt and Whitney's (P and W's) plan for integrating the analyses, testing, fabrication, and other program efforts is addressed. This plan offers a comprehensive description of the total effort required to design, fabricate, and test the ALS oxidizer turbopump. The proposed ALS oxidizer turbopump reduces turbopump costs over current designs by taking advantage of design simplicity and state-of-the-art materials and producibility features without compromising system reliability. This is accomplished by selecting turbopump operating conditions that are within known successful operating regions and by using proven manufacturing techniques.
The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions.
Mamiya, Yasuyuki; Nishio, Yoshiyuki; Watanabe, Hiroyuki; Yokoi, Kayoko; Uchiyama, Makoto; Baba, Toru; Iizuka, Osamu; Kanno, Shigenori; Kamimura, Naoto; Kazui, Hiroaki; Hashimoto, Mamoru; Ikeda, Manabu; Takeshita, Chieko; Shimomura, Tatsuo; Mori, Etsuro
2016-01-01
Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB), and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test. The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer's disease (AD) and 20 healthy controls (HCs). We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC) and the concurrent validity using the Neuropsychiatric Inventory (NPI) hallucinations score as a reference. A receiver operating characteristic (ROC) analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs. The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82), and moderately correlated with the NPI hallucinations score (rs = 0.42). Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%. Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB.
Development of modelling algorithm of technological systems by statistical tests
NASA Astrophysics Data System (ADS)
Shemshura, E. A.; Otrokov, A. V.; Chernyh, V. G.
2018-03-01
The paper tackles the problem of economic assessment of design efficiency regarding various technological systems at the stage of their operation. The modelling algorithm of a technological system was performed using statistical tests and with account of the reliability index allows estimating the level of machinery technical excellence and defining the efficiency of design reliability against its performance. Economic feasibility of its application shall be determined on the basis of service quality of a technological system with further forecasting of volumes and the range of spare parts supply.
Papinutto, N.; Schlaeger, R.; Panara, V.; Caverzasi, E.; Ahn, S.; Johnson, K.J.; Zhu, A.H.; Stern, W.A.; Laub, G.; Hauser, S.L.; Henry, R.G.
2018-01-01
PURPOSE In-vivo assessment of spinal cord gray matter (GM) and white matter (WM) could become pivotal to study various neurological diseases, but it is challenging because of insufficient GM/WM contrast provided by conventional MRI. Here we present and assess a procedure for measurement of spinal cord total cross-sectional area (TCA) and GM areas based on phase sensitive inversion recovery imaging (PSIR). MATERIALS AND METHODS We acquired 2D PSIR images at 3T at each disc level of the spinal axis on 10 healthy subjects and measured TCA, cord diameters, WM and GM area, and GM area/TCA ratio. We secondly investigated 32 healthy subjects at 4 selected levels (C2–C3, C3–C4, T8–T9, T9–T10, total acquisition time <8 minutes) and generated normative reference values of TCA and GM areas. We assessed test-retest, intra- and inter-operator reliability of the acquisition strategy and measurement steps. RESULTS The measurement procedure based on 2D PSIR imaging allowed TCA and GM area assessments along the entire spinal cord axis. The tests we performed revealed high test-retest/intra-operator reliability (mean coefficient of variation (COV) at C2–C3: TCA=0.41%, GM area=2.75%) and inter-operator reliability of the measurements (mean COV on the 4 levels: TCA=0.44%, GM area= 4.20%; mean intra-class correlation coefficient: TCA=0.998, GM area=0.906). CONCLUSION 2D PSIR allows reliable in-vivo assessment of spinal cord TCA, GM and WM areas in clinically feasible acquisition times. The area measurements presented here are in agreement with previous MRI and post-mortem studies. PMID:25483607
Sauer, Juergen; Chavaillaz, Alain
2017-01-01
This experiment aimed to examine how skill lay-off and system reliability would affect operator behaviour in a simulated work environment under wide-range and large-choice adaptable automation comprising six different levels. Twenty-four participants were tested twice during a 2-hr testing session, with the second session taking place 8 months after the first. In the middle of the second testing session, system reliability changed. The results showed that after the retention interval trust increased and self-confidence decreased. Complacency was unaffected by the lay-off period. Diagnostic speed slowed down after the retention interval but diagnostic accuracy was maintained. No difference between experimental conditions was found for automation management behaviour (i.e. level of automation chosen and frequency of switching between levels). There were few effects of system reliability. Overall, the findings showed that subjective measures were more sensitive to the impact of skill lay-off than objective behavioural measures. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Dugan, Joanne Bechta; Trivedi, Kishor S.; Mittal, Nitin; Boyd, Mark A.; Geist, Robert M.; Smotherman, Mark D.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed to be compatible with most computing platforms and operating systems, and some programs have been beta tested, within the aerospace community for over 8 years. Volume 1 provides an introduction to the HARP program. Comprehensive information on HARP mathematical models can be found in the references.
Life test of a xenon hollow cathode for a space plasma contractor
NASA Technical Reports Server (NTRS)
Sarver-Verhey, Timothy R.
1994-01-01
A plasma contacting device using a hollow cathode for plasma production has been baselined for use on the Space Station. This application will require reliable, continuous operation of the cathode at electron emission currents of between 0.75 and 10 A for two years (17,500 hours). In order to validate life-time capability, a hollow cathode, operated in a diode configuration, has been tested for more than 8600 hours of stable discharge operation as of March 30, 1994. This cathode is operated at a steady-state emission current of 12.0 and a fixed xenon flow rate of 4.5 sccm. Discharge voltage and cathode temperature have remained relatively stable at approximately 12.9 V and 1260 C during the test. The test has experienced 7 shutdowns to date. In all instances, the cathode was reignited at about 42 V and resumed stable operation. This test represents the longest demonstration of stable operation of high current (greater than 1A) xenon hollow cathodes reported to date.
A New Mobile Application for Standardizing Diabetic Foot Images.
Yap, Moi Hoon; Chatwin, Katie E; Ng, Choon-Ching; Abbott, Caroline A; Bowling, Frank L; Rajbhandari, Satyan; Boulton, Andrew J M; Reeves, Neil D
2018-01-01
We describe the development of a new mobile app called "FootSnap," to standardize photographs of diabetic feet and test its reliability on different occasions and between different operators. FootSnap was developed by a multidisciplinary team for use with the iPad. The plantar surface of 30 diabetic feet and 30 nondiabetic control feet were imaged using FootSnap on two separate occasions by two different operators. Reproducibility of foot images was determined using the Jaccard similarity index (JSI). High intra- and interoperator reliability was demonstrated with JSI values of 0.89-0.91 for diabetic feet and 0.93-0.94 for control feet. Similarly high reliability between groups indicates FootSnap is appropriate for longitudinal follow-ups in diabetic feet, with potential for monitoring pathology.
Flight Testing of the Capillary Pumped Loop 3 Experiment
NASA Technical Reports Server (NTRS)
Ottenstein, Laura; Butler, Dan; Ku, Jentung; Cheung, Kwok; Baldauff, Robert; Hoang, Triem
2002-01-01
The Capillary Pumped Loop 3 (CAPL 3) experiment was a multiple evaporator capillary pumped loop experiment that flew in the Space Shuttle payload bay in December 2001 (STS-108). The main objective of CAPL 3 was to demonstrate in micro-gravity a multiple evaporator capillary pumped loop system, capable of reliable start-up, reliable continuous operation, and heat load sharing, with hardware for a deployable radiator. Tests performed on orbit included start-ups, power cycles, low power tests (100 W total), high power tests (up to 1447 W total), heat load sharing, variable/fixed conductance transition tests, and saturation temperature change tests. The majority of the tests were completed successfully, although the experiment did exhibit an unexpected sensitivity to shuttle maneuvers. This paper describes the experiment, the tests performed during the mission, and the test results.
NASA Technical Reports Server (NTRS)
1974-01-01
System design and performance of the Skylab Airlock Module and Payload Shroud are presented for the communication and caution and warning systems. Crew station and storage, crew trainers, experiments, ground support equipment, and system support activities are also reviewed. Other areas documented include the reliability and safety programs, test philosophy, engineering project management, and mission operations support.
NASA Astrophysics Data System (ADS)
Petukhov, A. N.
2010-10-01
The problems related to the determination of the life of the structural materials applied for important parts in gas-turbine engines and power plants from the results of high-cycle fatigue tests are discussed. Methods for increasing the reliability of the high-cycle fatigue characteristics and the factors affecting the operational reliability are considered.
ERIC Educational Resources Information Center
Garcia Laborda, Jesus
2007-01-01
Interface design and ergonomics, while already studied in much of educational theory, have not until recently been considered in language testing (Fulcher, 2003). In this paper, we revise the design principles of PLEVALEX, a fully operational prototype Internet based language testing platform. Our focus here is to show PLEVALEX's interfaces and…
650-nm-band high-power and highly reliable laser diodes with a window-mirror structure
NASA Astrophysics Data System (ADS)
Shima, Akihiro; Hironaka, Misao; Ono, Ken-ichi; Takemi, Masayoshi; Sakamoto, Yoshifumi; Kunitsugu, Yasuhiro; Yamashita, Koji
1998-05-01
An active layer structure with 658 nm-emission at 25 degrees Celsius has been optimized in order to reduce the operating current of the laser diodes (LD) under high temperature condition. For improvement of the maximum output power and the reliability limited by mirror degradation, we have applied a zinc-diffused-type window-mirror structure which prevents the optical absorption at the mirror facet. As a result, the CW output power of 50 mW is obtained even at 80 degrees Celsius for a 650 micrometer-long window-mirror LD. In addition, the maximum light output power over 150 mW at 25 degrees Celsius has been realized without any optical mirror damage. In the aging tests, the LDs have been operating for over 2,500 - 5,000 hours under the CW condition of 30 - 50 mW at 60 degrees Celsius. The window-mirror structure also enables reliable 60 degree Celsius, 30 mW, CW operation of the LDs with 651 nm- emission at 25 degrees Celsius. Moreover, the maximum output power of around 100 mW even at 80 degrees Celsius and reliable 2,000-hour operation at 60 degrees Celsius, 70 mW have been realized for the first time by 659 nm LDs with a long cavity length of 900 micrometers.
Drive and protection circuit for converter module of cascaded H-bridge STATCOM
NASA Astrophysics Data System (ADS)
Wang, Xuan; Yuan, Hongliang; Wang, Xiaoxing; Wang, Shuai; Fu, Yongsheng
2018-04-01
Drive and protection circuit is an important part of power electronics, which is related to safe and stable operation issues in the power electronics. The drive and protection circuit is designed for the cascaded H-bridge STATCOM. This circuit can realize flexible dead-time setting, operation status self-detection, fault priority protection and detailed fault status uploading. It can help to improve the reliability of STATCOM's operation. Finally, the proposed circuit is tested and analyzed by power electronic simulation software PSPICE (Simulation Program with IC Emphasis) and a series of experiments. Further studies showed that the proposed circuit can realize drive and control of H-bridge circuit, meanwhile it also can realize fast processing faults and have advantage of high reliability.
Doorbar-Baptist, Stuart; Adams, Roger; Rebbeck, Trudy
2017-04-01
This study documents a protocol designed to evaluate pelvic floor motor control in men with prostate cancer. It also aims to evaluate the reliability of therapists in rating motor control of pelvic floor muscles (PFMs) using real time ultrasound imaging (RUSI) video clips. We further determine predictors of acquiring motor control. Ninety-one men diagnosed with prostate cancer attending a physiotherapy clinic for pelvic floor exercises were taught detailed pelvic floor motor control exercises by a physiotherapist using trans-abdominal RUSI for biofeedback. A new protocol to rate motor control skill acquisition was developed. Three independent physiotherapists assessed motor control skill attainment by viewing RUSI videos of the contractions. Inter-rater reliability was evaluated using intra-class correlation coefficients. Logistic regression analysis was conducted to identify predictors of successful skill attainment. Acquisition of the skill was compared between pre- and post-operative participants using an independent-group t-test. There was good reliability for rating the RUSI video clips (ICC 0.73 (95%CI 0.59-0.82)) for experienced therapists. Having low BMI and being seen pre-operatively predicted motor skill attainment, accounting for 46.3% of the variance. Significantly more patients trained pre-operatively acquired the skill of pelvic floor control compared with patients initially seen post-operatively (OR 11.87, 95%CI 1.4 to 99.5, p = 0.02). A new protocol to evaluate attainment of pelvic floor control in men with prostate cancer can be assessed reliably from RUSI images, and is most effectively delivered pre-operatively.
SNS Cryogenic Test Facility Kinney Vacuum Pump Commissioning and Operation at 2 K
NASA Astrophysics Data System (ADS)
DeGraff, B.; Howell, M.; Kim, S.; Neustadt, T.
2017-12-01
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) has built and commissioned an independent Cryogenic Test Facility (CTF) in support of testing in the Radio-frequency Test Facility (RFTF). Superconducting Radio-frequency Cavity (SRF) testing was initially conducted with the CTF cold box at 4.5 K. A Kinney vacuum pump skid consisting of a roots blower with a liquid ring backing pump was recently added to the CTF system to provide testing capabilities at 2 K. System design, pump refurbishment and installation of the Kinney pump will be presented. During the commissioning and initial testing period with the Kinney pump, several barriers to achieve reliable operation were experienced. Details of these lessons learned and improvements to skid operations will be presented. Pump capacity data will also be presented.
SNS Cryogenic Test Facility Kinney Vacuum Pump Commissioning and Operation at 2 K
DOE Office of Scientific and Technical Information (OSTI.GOV)
Degraff, Brian D.; Howell, Matthew P.; Kim, Sang-Ho
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) has built and commissioned an independent Cryogenic Test Facility (CTF) in support of testing in the Radio-frequency Test Facility (RFTF). Superconducting Radio-frequency Cavity (SRF) testing was initially conducted with the CTF cold box at 4.5 K. A Kinney vacuum pump skid consisting of a roots blower with a liquid ring backing pump was recently added to the CTF system to provide testing capabilities at 2 K. System design, pump refurbishment and installation of the Kinney pump will be presented. During the commissioning and initial testing period with the Kinneymore » pump, several barriers to achieve reliable operation were experienced. Details of these lessons learned and improvements to skid operations will be presented. Pump capacity data will also be presented.« less
Capacitance discharge system for ignition of Single Bridge Apollo Standard Initiators (SBASI)
NASA Technical Reports Server (NTRS)
Ward, R. D.
1974-01-01
The design support data developed during the single bridge Apollo standard initiator (SBASI) program are presented. A circuit was designed and bread-board tested to verify operational capabilities of the circuit. Test data, design criteria, weight, and reliability trade-off considerations, and final design recommendations are reported.
Anaphylaxis to Gelofusine confirmed by in vitro basophil activation test: a case series.
Apostolou, E; Deckert, K; Puy, R; Sandrini, A; de Leon, M P; Douglass, J A; Rolland, J M; O'hehir, R E
2006-03-01
The plasma expander Gelofusine (succinylated gelatin) is a recognised cause of peri-operative anaphylaxis. Current diagnosis of Gelofusine sensitivity is by skin testing, a procedure that itself carries a risk of allergic reaction. We evaluated the reliability of the in vitro basophil activation test as a diagnostic assay for Gelofusine sensitivity in subjects with a clinical history highly suggestive of Gelofusine allergy. Six patients with peri-operative anaphylaxis clinically attributed to Gelofusine were skin tested to confirm sensitivity. Control subjects included three healthy subjects and five subjects allergic to a neuromuscular blocking drug, all negative on Gelofusine skin testing. Whole blood basophil activation to Gelofusine was analysed by flow cytometry for CD63 surface expression. All of the Gelofusine sensitive patients and one of the control allergic subjects showed positive basophil activation to Gelofusine. In this series of subjects, the basophil activation test for Gelofusine allergy had a sensitivity of 100% and a specificity of 87.5%. Our findings suggest that basophil activation testing is a safe and reliable in vitro assay for prediction or confirmation of Gelofusine sensitivity in patients with high clinical suspicion of Gelofusine-induced anaphylaxis.
Environmental and reliability test of FBG based geophone as geophysical exploration instrument
NASA Astrophysics Data System (ADS)
Zhang, Xiaolei; Min, Li; Li, Ming; Jiang, Shaodong; Zhang, Faxiang; Sun, Zhihui; Ni, Jiasheng; Peng, Gangding; Wang, Chang
2017-10-01
A fiber Bragg grating (FBG) based geophone is designed for low-frequency signal detection has high acceleration response of about 60 dB re pm/g in a low frequency range of 5 Hz 60 Hz. To Guarantee normal operation in field test and practical application, an acceleration amplitude restriction is added in the mechanical design of the FBG geophone. Then a series of environmental and reliability test have been proceeded with online or offline monitoring of its working performance, including high and low temperature test, vibration test, shock test and free drop test. All the tests are planned according to National standard or Oil & Gas Industry Standard. And the experimental results indicate that our FBG geophone meet the criterion of oil and gas industry product and is capable of field application.
Effectiveness of spacecraft testing programs
NASA Technical Reports Server (NTRS)
Krausz, A.
1980-01-01
The need for testing under simulated mission operational conditions is discussed and the results of such tests are reviewed from the point of view of the user. A brief overview of the usal test sequences for high reliability long life spacecraft is presented and the effectiveness of the testing program is analyzed in terms of the defects which are discovered by such tests. The need for automation, innovative mechanical test procedures, and design for testability is discussed.
Henrickson Parker, Sarah; Flin, Rhona; McKinley, Aileen; Yule, Steven
2013-06-01
Surgeons must demonstrate leadership to optimize performance and maximize patient safety in the operating room, but no behavior rating tool is available to measure leadership. Ten focus groups with members of the operating room team discussed surgeons' intraoperative leadership. Surgeons' leadership behaviors were extracted and used to finalize the Surgeons' Leadership Inventory (SLI), which was checked by surgeons (n = 6) for accuracy and face validity. The SLI was used to code video recordings (n = 5) of operations to test reliability. Eight elements of surgeons' leadership were included in the SLI: (1) maintaining standards, (2) managing resources, (3) making decisions, (4) directing, (5) training, (6) supporting others, (7) communicating, and (8) coping with pressure. Interrater reliability to code videos of surgeons' behaviors while operating using this tool was acceptable (κ = .70). The SLI is empirically grounded in focus group data and both the leadership and surgical literature. The interrater reliability of the system was acceptable. The inventory could be used for rating surgeons' leadership in the operating room for research or as a basis for postoperative feedback on performance. Copyright © 2013 Elsevier Inc. All rights reserved.
Stirling machine operating experience
NASA Technical Reports Server (NTRS)
Ross, Brad; Dudenhoefer, James E.
1991-01-01
Numerous Stirling machines have been built and operated, but the operating experience of these machines is not well known. It is important to examine this operating experience in detail, because it largely substantiates the claim that Stirling machines are capable of reliable and lengthy lives. The amount of data that exists is impressive, considering that many of the machines that have been built are developmental machines intended to show proof of concept, and were not expected to operate for any lengthy period of time. Some Stirling machines (typically free-piston machines) achieve long life through non-contact bearings, while other Stirling machines (typically kinematic) have achieved long operating lives through regular seal and bearing replacements. In addition to engine and system testing, life testing of critical components is also considered.
Tabard-Fougère, Anne; Bonnefoy-Mazure, Alice; Hanquinet, Sylviane; Lascombes, Pierre; Armand, Stéphane; Dayer, Romain
2017-01-15
Test-retest study. This study aimed to evaluate the validity and reliability of rasterstereography in patients with adolescent idiopathic scoliosis (AIS) with a major curve Cobb angle (CA) between 10° and 40° for frontal, sagittal, and transverse parameters. Previous studies evaluating the validity and reliability of rasterstereography concluded that this technique had good accuracy compared with radiographs and a high intra- and interday reliability in healthy volunteers. To the best of our knowledge, the validity and reliability have not been assessed in AIS patients. Thirty-five adolescents with AIS (male = 13) aged 13.1 ± 2.0 years were included. To evaluate the validity of the scoliosis angle (SA) provided by rasterstereography, a comparison (t test, Pearson correlation) was performed with the CA obtained using 2D EOS® radiography (XR). Three rasterstereographic repeated measurements were independently performed by two operators on the same day (interrater reliability) and again by the first operator 1 week later (intrarater reliability). The variables of interest were the SA, lumbar lordosis, and thoracic kyphosis angle, trunk length, pelvic obliquity, and maximum, root mean square and amplitude of vertebral rotations. The data analyses used intraclass correlation coefficients (ICCs). The CA and SA were strongly correlated (R = 0.70) and were nonsignificantly different (P = 0.60). The intrarater reliability (same day: ICC [1, 1], n = 35; 1 week later: ICC [1, 3], n = 28) and interrater reliability (ICC [3, 3], n = 16) were globally excellent (ICC > 0.75) except for the assessment of pelvic obliquity. This study showed that the rasterstereographic system allows for the evaluation of AIS patients with a good validity compared with XR with an overall excellent intra- and interrater reliability. Based on these results, this automatic, fast, and noninvasive system can be used for monitoring the evolution of AIS in growing patients instead of repetitive radiographs, thereby reducing radiation exposure and decreasing costs. 4.
Cell emulation and preliminary results.
DOT National Transportation Integrated Search
2016-07-01
This report details preliminary results of the testing plan implemented by the Hawaii Natural Energy Institute to evaluate Electric Vehicle (EV) battery durability and reliability under electric utility grid operations. Commercial EV battery cells ar...
Free-piston Stirling component test power converter
NASA Technical Reports Server (NTRS)
Dochat, George; Dhar, Manmohan
1991-01-01
The National Aeronautics and Space Administration (NASA) has been evaluating free-piston Stirling power converters (FPSPCs) for use on a wide variety of space missions. They provide high reliability, long life, and efficient operation and can be coupled with all potential heat sources, various heat input and heat rejection systems, and various power management and distribution systems. FPSPCs can compete favorably with alternative power conversion systems over a range of hundreds of watts to megawatts. Mechanical Technology Incorporated (MTI) is developing FPSPC technology under contract to NASA Lewis Research Center and will demonstrate this technology in two full-scale power converters operating at space temperature conditions. The testing of the first of these, the component test power converter (CTPC), was initiated in Spring 1991 to evaluate mechanical operation at space operating temperatures. The CTPC design, hardware fabrication, and initial test results are reviewed.
Deformation of Cases in High Capacitance Value Wet Tantalum Capacitors under Environmental Stresses
NASA Technical Reports Server (NTRS)
Teverovsky, Alexander
2016-01-01
Internal gas pressure in hermetic wet tantalum capacitors is created by air, electrolyte vapor, and gas generated by electrochemical reactions at the electrodes. This pressure increases substantially with temperature and time of operation due to excessive leakage currents. Deformation of the case occurs when the internal pressure exceeds pressure of the environments and can raise significantly when a part operates in space. Contrary to the cylinder case wet tantalum capacitors that have external sealing by welding and internal sealing provided by the Teflon bushing and crimping of the case, no reliable internal sealing exists in the button case capacitors. Single seal design capacitors are used for high capacitance value wet tantalum capacitors manufactured per DLA L&M drawings #04003, 04005, and 10011, and require additional analysis to assure their reliable application in space systems. In this work, leakage currents and case deformation of button case capacitors were measured during different environmental test conditions. Recommendations for derating, screening and qualification testing are given. This work is a continuation of a series of NEPP reports related to quality and reliability of wet tantalum capacitors.
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Schreiber, Jeffre G.; Wilson, Scott D.; oriti, Salvatore M.; Cornell, Peggy; Schifer, Nicholas
2008-01-01
100 We class Stirling convertors began extended operation testing at NASA Glenn Research Center (GRC) in 2003 with a pair of Technology Demonstration Convertors (TDCs) operating in air. Currently, the number of convertors on extended operation test has grown to 12, including both TDCs and Advanced Stirling Convertors (ASCs) operating both in air and in thermal vacuum. Additional convertors and an electrically heated radioisotope generator will be put on test in the near future. This testing has provided data to support life and reliability estimates and the quality improvements and design changes that have been made to the convertor. The convertors operated 24/7 at the nominal amplitude and power levels. Performance data were recorded on an hourly basis. Techniques to monitor the convertors for change in internal operation included gas analysis, vibration measurements and acoustic emission measurements. This data provided a baseline for future comparison. This paper summarizes the results of over 145,000 hours of TDC testing and 40,000 hours of ASC testing and discusses trends in the data. Data shows the importance of improved materials, hermetic sealing, and quality processes in maintaining convertor performance over long life.
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Schreiber, Jeffrey G.; Wilson, Scott D.; Oriti, Salvatore M.; Cornell, Peggy; Schifer, Nicholas
2009-01-01
100 We class Stirling convertors began extended operation testing at NASA Glenn Research Center (GRC) in 2003 with a pair of Technology Demonstration Convertors (TDCs) operating in air. Currently, the number of convertors on extended operation test has grown to 12, including both TDCs and Advanced Stirling Convertors (ASCs) operating both in air and in thermal vacuum. Additional convertors and an electrically heated radioisotope generator will be put on test in the near future. This testing has provided data to support life and reliability estimates and the quality improvements and design changes that have been made to the convertor. The convertors operated 24/7 at the nominal amplitude and power levels. Performance data were recorded on an hourly basis. Techniques to monitor the convertors for change in internal operation included gas analysis, vibration measurements, and acoustic emission measurements. This data provided a baseline for future comparison. This paper summarizes the results of over 145,000 hr of TDC testing and 40,000 hr of ASC testing and discusses trends in the data. Data shows the importance of improved materials, hermetic sealing, and quality processes in maintaining convertor performance over long life.
ESOC's System for Interplanetary Orbit Determination: Implementation and Operational Experience
NASA Astrophysics Data System (ADS)
Budnik, F.; Morley, T. A.; MacKenzie, R. A.
A system for interplanetary orbit determination has been developed at ESOC over the past six years. Today, the system is in place and has been proven to be both reliable and robust by successfully supporting critical operations of ESA's interplanetary spacecraft Rosetta, Mars Express, and SMART-1. To reach this stage a long and challenging way had to be travelled. This paper gives a digest about the journey from the development and testing to the operational use of ESOC's new interplanetary orbit determination system. It presents the capabilities and reflects experiences gained from the performed tests and tracking campaigns.
Reliable high-power diode lasers: thermo-mechanical fatigue aspects
NASA Astrophysics Data System (ADS)
Klumel, Genady; Gridish, Yaakov; Szafranek, Igor; Karni, Yoram
2006-02-01
High power water-cooled diode lasers are finding increasing demand in biomedical, cosmetic and industrial applications, where repetitive cw (continuous wave) and pulsed cw operation modes are required. When operating in such modes, the lasers experience numerous complete thermal cycles between "cold" heat sink temperature and the "hot" temperature typical of thermally equilibrated cw operation. It is clearly demonstrated that the main failure mechanism directly linked to repetitive cw operation is thermo-mechanical fatigue of the solder joints adjacent to the laser bars, especially when "soft" solders are used. Analyses of the bonding interfaces were carried out using scanning electron microscopy. It was observed that intermetallic compounds, formed already during the bonding process, lead to the solders fatigue both on the p- and n-side of the laser bar. Fatigue failure of solder joints in repetitive cw operation reduces useful lifetime of the stacks to hundreds hours, in comparison with more than 10,000 hours lifetime typically demonstrated in commonly adopted non-stop cw reliability testing programs. It is shown, that proper selection of package materials and solders, careful design of fatigue sensitive parts and burn-in screening in the hard pulse operation mode allow considerable increase of lifetime and reliability, without compromising the device efficiency, optical power density and compactness.
Real time test bed development for power system operation, control and cyber security
NASA Astrophysics Data System (ADS)
Reddi, Ram Mohan
The operation and control of the power system in an efficient way is important in order to keep the system secure, reliable and economical. With advancements in smart grid, several new algorithms have been developed for improved operation and control. These algorithms need to be extensively tested and validated in real time before applying to the real electric power grid. This work focuses on the development of a real time test bed for testing and validating power system control algorithms, hardware devices and cyber security vulnerability. The test bed developed utilizes several hardware components including relays, phasor measurement units, phasor data concentrator, programmable logic controllers and several software tools. Current work also integrates historian for power system monitoring and data archiving. Finally, two different power system test cases are simulated to demonstrate the applications of developed test bed. The developed test bed can also be used for power system education.
Psychometric evaluation of a motor control test battery of the craniofacial region.
von Piekartz, H; Stotz, E; Both, A; Bahn, G; Armijo-Olivo, S; Ballenberger, N
2017-12-01
The primary objective of this study was to determine the structural and known-group validity as well as the inter-rater reliability of a test battery to evaluate the motor control of the craniofacial region. Seventy volunteers without TMD and 25 subjects with TMD (Axes I) per the DC/TMD were asked to execute a test battery consisting of eight tests. The tests were video-taped in the same sequence in a standardised manner. Two experienced physical therapists participated in this study as blinded assessors. We used exploratory factor analysis to identify the underlying component structure of the eight tests. Internal consistency (Cronbach's α), inter-rater reliability (intra-class correlation coefficient) and construct validity (ie, hypothesis testing-known-group validity) (receiver operating curves) were also explored for the test battery. The structural validity showed the presence of one factor underlying the construct of the test battery. The internal consistency was excellent (0.90) as well as the inter-rater reliability. All values of reliability were close to 0.9 or above indicating very high inter-rater reliability. The area under the curve (AUC) was 0.93 for rater 1 and 0.94 for rater two, respectively, indicating excellent discrimination between subjects with TMD and healthy controls. The results of the present study support the psychometric properties of test battery to measure motor control of the craniofacial region when evaluated through videotaping. This test battery could be used to differentiate between healthy subjects and subjects with musculoskeletal impairments in the cervical and oro-facial regions. In addition, this test battery could be used to assess the effectiveness of management strategies in the craniofacial region. © 2017 John Wiley & Sons Ltd.
Pyrotechnically Operated Valves for Testing and Flight
NASA Technical Reports Server (NTRS)
Conley, Edgar G.; St.Cyr, William (Technical Monitor)
2002-01-01
Pyrovalves still warrant careful description of their operating characteristics, which is consistent with the NASA mission - to assure that both testing and flight hardware perform with the utmost reliability. So, until the development and qualification of the next generation of remotely controlled valves, in all likelihood based on shape memory alloy technology, pyrovalves will remain ubiquitous in controlling flow systems aloft and will possibly see growing use in ground-based testing facilities. In order to assist NASA in accomplishing this task, we propose a three-phase, three-year testing program. Phase I would set up an experimental facility, a 'test rig' in close cooperation with the staff located at the White Sands Test Facility in Southern New Mexico.
PV industry growth and module reliability in Thailand
NASA Astrophysics Data System (ADS)
Chenvidhya, Dhirayut; Seapan, Manit; Sangpongsanont, Yaowanee; Chenvidhya, Tanokkorn; Limsakul, Chamnan; Songprakorp, Roongrojana
2015-09-01
The PV applications in Thailand are now installed more than 1.2 GWp cumulatively. It is due to the National Renewable Energy Program and its targets. In the latest Alternative Energy Development Plan (AEDP), the PV electricity production target has increased from 2 GWp to 3 GWp. With this rapid growth, customers and manufacturers seek for module standard testing. So far over one thousands of PV modules per annum have been tested since 2012. The normal tests include type approval test according to TIS standard, acceptance test and testing for local standard development. For type test, the most module failure was found during damp heat test. For annual evaluation test, the power degradation and delamination of power was found between 0 to 6 percent from its nameplate after deployment of 0 to 5 years in the field. For thin-film module, the degradation and delamination was found in range of 0 to 13 percent (about 5 percent on average) from its nameplate for the modules in operation with less than 5 years. However, for the PV modules at the reference site on campus operated for 12 years, the power degradation was ranging from 10 to 15 percent. Therefore, a long term performance assessment needs to be considered to ensure the system reliability.
The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions
Mamiya, Yasuyuki; Nishio, Yoshiyuki; Watanabe, Hiroyuki; Yokoi, Kayoko; Uchiyama, Makoto; Baba, Toru; Iizuka, Osamu; Kanno, Shigenori; Kamimura, Naoto; Kazui, Hiroaki; Hashimoto, Mamoru; Ikeda, Manabu; Takeshita, Chieko; Shimomura, Tatsuo; Mori, Etsuro
2016-01-01
Background Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB), and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test. Methods The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer’s disease (AD) and 20 healthy controls (HCs). We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC) and the concurrent validity using the Neuropsychiatric Inventory (NPI) hallucinations score as a reference. A receiver operating characteristic (ROC) analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs. Results The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82), and moderately correlated with the NPI hallucinations score (rs = 0.42). Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%. Conclusions Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB. PMID:27171377
NASA Astrophysics Data System (ADS)
Black, Stephen T.; Eshleman, Wally
1997-01-01
This paper describes the VentureStar™ SSTO RLV and X-33 operations concepts. Applications of advanced technologies, automated ground support systems, advanced aircraft and launch vehicle lessons learned have been integrated to develop a streamlined vehicle and mission processing concept necessary to meet the goals of a commercial SSTO RLV. These concepts will be validated by the X-33 flight test program where financial and technical risk mitigation are required. The X-33 flight test program totally demonstrates the vehicle performance, technology, and efficient ground operations at the lowest possible cost. The Skunk Work's test program approach and test site proximity to the production plant are keys. The X-33 integrated flight and ground test program incrementally expands the knowledge base of the overall system allowing minimum risk progression to the next flight test program milestone. Subsequent X-33 turnaround processing flows will be performed with an aircraft operations philosophy. The differences will be based on research and development, component reliability and flight test requirements.
Prognostics-based qualification of high-power white LEDs using Lévy process approach
NASA Astrophysics Data System (ADS)
Yung, Kam-Chuen; Sun, Bo; Jiang, Xiaopeng
2017-01-01
Due to their versatility in a variety of applications and the growing market demand, high-power white light-emitting diodes (LEDs) have attracted considerable attention. Reliability qualification testing is an essential part of the product development process to ensure the reliability of a new LED product before its release. However, the widely used IES-TM-21 method does not provide comprehensive reliability information. For more accurate and effective qualification, this paper presents a novel method based on prognostics techniques. Prognostics is an engineering technology predicting the future reliability or determining the remaining useful lifetime (RUL) of a product by assessing the extent of deviation or degradation from its expected normal operating conditions. A Lévy subordinator of a mixed Gamma and compound Poisson process is used to describe the actual degradation process of LEDs characterized by random sporadic small jumps of degradation degree, and the reliability function is derived for qualification with different distribution forms of jump sizes. The IES LM-80 test results reported by different LED vendors are used to develop and validate the qualification methodology. This study will be helpful for LED manufacturers to reduce the total test time and cost required to qualify the reliability of an LED product.
NASA Astrophysics Data System (ADS)
Park, Sangwook; Lee, Young-Ran; Hwang, Yoola; Javier Santiago Noguero Galilea
2009-12-01
This paper describes the Flight Dynamics Automation (FDA) system for COMS Flight Dynamics System (FDS) and its test result in terms of the performance of the automation jobs. FDA controls the flight dynamics functions such as orbit determination, orbit prediction, event prediction, and fuel accounting. The designed FDA is independent from the specific characteristics which are defined by spacecraft manufacturer or specific satellite missions. Therefore, FDA could easily links its autonomous job control functions to any satellite mission control system with some interface modification. By adding autonomous system along with flight dynamics system, it decreases the operator’s tedious and repeated jobs but increase the usability and reliability of the system. Therefore, FDA is used to improve the completeness of whole mission control system’s quality. The FDA is applied to the real flight dynamics system of a geostationary satellite, COMS and the experimental test is performed. The experimental result shows the stability and reliability of the mission control operations through the automatic job control.
Photovoltaic-Powered Vaccine Refrigerator: Freezer Systems Field Test Results
NASA Technical Reports Server (NTRS)
Ratajczak, A. F.
1985-01-01
A project to develop and field test photovoltaic-powered refrigerator/freezers suitable for vaccine storage was undertaken. Three refrigerator/freezers were qualified; one by Solar Power Corp. and two by Solvolt. Follow-on contracts were awarded for 19 field test systems and for 10 field test systems. A total of 29 systems were installed in 24 countries between October 1981 and October 1984. The project, systems descriptions, installation experiences, performance data for the 22 systems for which field test data was reported, an operational reliability summary, and recommendations relative to system designs and future use of such systems are explained. Performance data indicate that the systems are highly reliable and are capable of maintaining proper vaccine storage temperatures in a wide range of climatological and user environments.
Reliability improvement of wire bonds subjected to fatigue stresses.
NASA Technical Reports Server (NTRS)
Ravi, K. V.; Philofsky, E. M.
1972-01-01
The failure of wire bonds due to repeated flexure when semiconductor devices are operated in an on-off mode has been investigated. An accelerated fatigue testing apparatus was constructed and the major fatigue variables, aluminum alloy composition, and bonding mechanism, were tested. The data showed Al-1% Mg wires to exhibit superior fatigue characteristics compared to Al-1% Cu or Al-1% Si and ultrasonic bonding to be better than thermocompression bonding for fatigue resistance. Based on these results highly reliable devices were fabricated using Al-1% Mg wire with ultrasonic bonding which withstood 120,000 power cycles with no failures.
Reliability-Based Life Assessment of Stirling Convertor Heater Head
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Halford, Gary R.; Korovaichuk, Igor
2004-01-01
Onboard radioisotope power systems being developed and planned for NASA's deep-space missions require reliable design lifetimes of up to 14 yr. The structurally critical heater head of the high-efficiency Stirling power convertor has undergone extensive computational analysis of operating temperatures, stresses, and creep resistance of the thin-walled Inconel 718 bill of material. A preliminary assessment of the effect of uncertainties in the material behavior was also performed. Creep failure resistance of the thin-walled heater head could show variation due to small deviations in the manufactured thickness and in uncertainties in operating temperature and pressure. Durability prediction and reliability of the heater head are affected by these deviations from nominal design conditions. Therefore, it is important to include the effects of these uncertainties in predicting the probability of survival of the heater head under mission loads. Furthermore, it may be possible for the heater head to experience rare incidences of small temperature excursions of short duration. These rare incidences would affect the creep strain rate and, therefore, the life. This paper addresses the effects of such rare incidences on the reliability. In addition, the sensitivities of variables affecting the reliability are quantified, and guidelines developed to improve the reliability are outlined. Heater head reliability is being quantified with data from NASA Glenn Research Center's accelerated benchmark testing program.
Test Hardware Design for Flightlike Operation of Advanced Stirling Convertors (ASC-E3)
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.
2012-01-01
NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.
Test Hardware Design for Flight-Like Operation of Advanced Stirling Convertors
NASA Technical Reports Server (NTRS)
Oriti, Salvatore M.
2012-01-01
NASA Glenn Research Center (GRC) has been supporting development of the Advanced Stirling Radioisotope Generator (ASRG) since 2006. A key element of the ASRG project is providing life, reliability, and performance testing of the Advanced Stirling Convertor (ASC). For this purpose, the Thermal Energy Conversion branch at GRC has been conducting extended operation of a multitude of free-piston Stirling convertors. The goal of this effort is to generate long-term performance data (tens of thousands of hours) simultaneously on multiple units to build a life and reliability database. The test hardware for operation of these convertors was designed to permit in-air investigative testing, such as performance mapping over a range of environmental conditions. With this, there was no requirement to accurately emulate the flight hardware. For the upcoming ASC-E3 units, the decision has been made to assemble the convertors into a flight-like configuration. This means the convertors will be arranged in the dual-opposed configuration in a housing that represents the fit, form, and thermal function of the ASRG. The goal of this effort is to enable system level tests that could not be performed with the traditional test hardware at GRC. This offers the opportunity to perform these system-level tests much earlier in the ASRG flight development, as they would normally not be performed until fabrication of the qualification unit. This paper discusses the requirements, process, and results of this flight-like hardware design activity.
Data pieces-based parameter identification for lithium-ion battery
NASA Astrophysics Data System (ADS)
Gao, Wei; Zou, Yuan; Sun, Fengchun; Hu, Xiaosong; Yu, Yang; Feng, Sen
2016-10-01
Battery characteristics vary with temperature and aging, it is necessary to identify battery parameters periodically for electric vehicles to ensure reliable State-of-Charge (SoC) estimation, battery equalization and safe operation. Aiming for on-board applications, this paper proposes a data pieces-based parameter identification (DPPI) method to identify comprehensive battery parameters including capacity, OCV (open circuit voltage)-Ah relationship and impedance-Ah relationship simultaneously only based on battery operation data. First a vehicle field test was conducted and battery operation data was recorded, then the DPPI method is elaborated based on vehicle test data, parameters of all 97 cells of the battery package are identified and compared. To evaluate the adaptability of the proposed DPPI method, it is used to identify battery parameters of different aging levels and different temperatures based on battery aging experiment data. Then a concept of ;OCV-Ah aging database; is proposed, based on which battery capacity can be identified even though the battery was never fully charged or discharged. Finally, to further examine the effectiveness of the identified battery parameters, they are used to perform SoC estimation for the test vehicle with adaptive extended Kalman filter (AEKF). The result shows good accuracy and reliability.
75 FR 72664 - System Personnel Training Reliability Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-26
...Under section 215 of the Federal Power Act, the Commission approves two Personnel Performance, Training and Qualifications (PER) Reliability Standards, PER-004-2 (Reliability Coordination--Staffing) and PER-005-1 (System Personnel Training), submitted to the Commission for approval by the North American Electric Reliability Corporation, the Electric Reliability Organization certified by the Commission. The approved Reliability Standards require reliability coordinators, balancing authorities, and transmission operators to establish a training program for their system operators, verify each of their system operators' capability to perform tasks, and provide emergency operations training to every system operator. The Commission also approves NERC's proposal to retire two existing PER Reliability Standards that are replaced by the standards approved in this Final Rule.
Reliability evaluation methodology for NASA applications
NASA Technical Reports Server (NTRS)
Taneja, Vidya S.
1992-01-01
Liquid rocket engine technology has been characterized by the development of complex systems containing large number of subsystems, components, and parts. The trend to even larger and more complex system is continuing. The liquid rocket engineers have been focusing mainly on performance driven designs to increase payload delivery of a launch vehicle for a given mission. In otherwords, although the failure of a single inexpensive part or component may cause the failure of the system, reliability in general has not been considered as one of the system parameters like cost or performance. Up till now, quantification of reliability has not been a consideration during system design and development in the liquid rocket industry. Engineers and managers have long been aware of the fact that the reliability of the system increases during development, but no serious attempts have been made to quantify reliability. As a result, a method to quantify reliability during design and development is needed. This includes application of probabilistic models which utilize both engineering analysis and test data. Classical methods require the use of operating data for reliability demonstration. In contrast, the method described in this paper is based on similarity, analysis, and testing combined with Bayesian statistical analysis.
Fuel Cell Balance-of-Plant Reliability Testbed Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sproat, Vern; LaHurd, Debbie
Reliability of the fuel cell system balance-of-plant (BoP) components is a critical factor that needs to be addressed prior to fuel cells becoming fully commercialized. Failure or performance degradation of BoP components has been identified as a life-limiting factor in fuel cell systems.1 The goal of this project is to develop a series of test beds that will test system components such as pumps, valves, sensors, fittings, etc., under operating conditions anticipated in real Polymer Electrolyte Membrane (PEM) fuel cell systems. Results will be made generally available to begin removing reliability as a roadblock to the growth of the PEMmore » fuel cell industry. Stark State College students participating in the project, in conjunction with their coursework, have been exposed to technical knowledge and training in the handling and maintenance of hydrogen, fuel cells and system components as well as component failure modes and mechanisms. Three test beds were constructed. Testing was completed on gas flow pumps, tubing, and pressure and temperature sensors and valves.« less
Ye, Siqin; Rabbani, LeRoy E.; Kelly, Christopher R.; Kelly, Maureen R.; Lewis, Matthew; Paz, Yehuda; Peck, Clara L.; Rao, Shaline; Bokhari, Sabahat; Weiner, Shepard D.; Einstein, Andrew J.
2014-01-01
Background We sought to determine inter-rater reliability of the 2009 Appropriate Use Criteria (AUC) for radionuclide imaging (RNI) and whether physicians at various levels of training can effectively identify nuclear stress tests with inappropriate indications. Methods and Results Four hundred patients were randomly selected from a consecutive cohort of patients undergoing nuclear stress testing at an academic medical center. Raters with different levels of training (including cardiology attending physicians, cardiology fellows, internal medicine hospitalists, and internal medicine interns) classified individual nuclear stress tests using the 2009 AUC. Consensus classification by two cardiologists was considered the operational gold standard, and sensitivity and specificity of individual raters for identifying inappropriate tests was calculated. Inter-rater reliability of the AUC was assessed using Cohen’s kappa statistics for pairs of different raters. The mean age of patients was 61.5 years; 214 (54%) were female. The cardiologists rated 256 (64%) of 400 NSTs as appropriate, 68 (18%) as uncertain, 55 (14%) as inappropriate; 21 (5%) tests were unable to be classified. Inter-rater reliability for non-cardiologist raters was modest (unweighted Cohen’s kappa, 0.51, 95% confidence interval, 0.45 to 0.55). Sensitivity of individual raters for identifying inappropriate tests ranged from 47% to 82%, while specificity ranged from 85% to 97%. Conclusions Inter-rater reliability for the 2009 AUC for RNI is modest, and there is considerable variation in the ability of raters at different levels of training to identify inappropriate tests. PMID:25563660
Pakarinen, Harri
2012-12-01
The aim of this thesis was to confirm the utility of stability-based ankle fracture classification in choosing between non-operative and operative treatment of ankle fractures, to determine how many ankle fractures are amenable to non-operative treatment, to assess the roles of the exploration and anatomical repair of the AITFL in the outcome of patients with SER ankle fractures, to establish the sensitivities, specificities and interobserver reliabilities of the hook and intraoperative stress tests for diagnosing syndesmosis instability in SER ankle fractures, and to determine whether transfixation of unstable syndesmosis is necessary in SER ankle fractures. The utility of stability based fracture classification to choose between non-operative and operative treatment was assessed in a retrospective study (1) of 253 ankle fractures in skeletally mature patients, 160 of whom were included in the study to obtain an epidemiological profile in a population of 130,000. Outcome was assessed after a minimum follow-up of two years. The role of AITFL repairs was assessed in a retrospective study (2) of 288 patients with Lauge-Hansen SE4 ankle fractures; the AITFL was explored and repaired in one group (n=165), and a similar operative method was used but the AITFL was not explored in another group (n=123). Outcome was measured with a minimum follow-up of two years. Interobserver reliability of clinical syndesomosis tests (study 3) and the role of syndesmosis transfixation (study 4) were assessed in a prospective study of 140 patients with Lauge-Hansen SE4 ankle fractures. The stability of the distal tibiofibular joint was evaluated by the hook and ER stress tests. Clinical tests were carried out by the main surgeon and assistant, separately, after which a 7.5-Nm standardized ER stress test for both ankles was performed; if it was positive, the patient was randomized to either syndesmosis transfixation (13 patients) or no fixation (11 patients) treatment groups. The sensitivity and specificity of both clinical tests were calculated using the standard 7.5-Nm external rotation stress test as reference. Outcome was assessed after a minimum of one year of follow-up. Olerud-Molander (OM) scoring system, RAND 36-Item Health Survey, and VAS to measure pain and function were used as outcome measures in all studies. In study 1, 85 (53%) fractures were treated operatively using the stability based fracture classification. Non-operatively treated patients reported less pain and better OM (good or excellent 89% vs. 71%) and VAS functional scores compared to operatively treated patients although they experienced more displacement of the distal fibula (0 mm 30% vs. 69%; 0-2 mm 65% vs. 25%) after treatment. No non-operatively treated patients required operative fracture fixation during follow-up. In study 2, AITFL exploration and suture lead to equal functional outcome (OM mean, 77 vs. 73) to no exploration or fixation. In study 3, the hook test had a sensitivity of 0.25 and a specificity of 0.98. The external rotation stress test had a sensitivity of 0.58 and a specificity of 0.9. Both tests had excellent interobserver reliability; the agreement was 99% for the hook test and 98% for the stress test. There was no statistically significant difference in functional scores (OM mean, 79.6 vs. 83.6) or pain between syndesmosis transfixation and no fixation groups (Study 4). Our results suggest that a simple stability-based fracture classification is useful in choosing between non-operative and operative treatment of ankle fractures; approximately half of the ankle fractures can be treated non-operatively with success. Our observations also suggest that relevant syndesmosis injuries are rare in ankle fractures due to an SER mechanism of injury. According to our research, syndesmotic repair or fixation in SER ankle fracture has no influence on functional outcome or pain after minimum one year compared with no fixation.
Development flight tests of JetStar LFC leading-edge flight test experiment
NASA Technical Reports Server (NTRS)
Fisher, David F.; Fischer, Michael C.
1987-01-01
The overall objective of the flight tests on the JetStar aircraft was to demonstrate the effectiveness and reliability of laminar flow control under representative flight conditions. One specific objective was to obtain laminar flow on the JetStar leading-edge test articles for the design and off-design conditions. Another specific objective was to obtain operational experience on a Laminar Flow Control (LFC) leading-edge system in a simulated airline service. This included operational experience with cleaning requirements, the effect of clogging, possible foreign object damage, erosion, and the effects of ice particle and cloud encounters. Results are summarized.
Facilities and support systems for a 90-day test of a regenerative life support system
NASA Technical Reports Server (NTRS)
Malin, R. L.
1972-01-01
A 90-day test is reported of a regenerative life support system which was completed in a space station simulator. The long duration of the test and the fact that it was manned, imposed rigid reliability and safety requirements on the facility. Where adequate reliability could not be built into essential facility systems, either backup systems or components were provided. Awareness was intensified by: (1) placing signs on every piece of equipment that could affect the test, (2) painting switches on all breaker panels a bright contrasting color, (3) restricting access to the test control area, and (4) informing personnel in the facility (other than test personnel) of test activities. It is concluded that the basic facility is satisfactory for conducting long-duration manned tests, and it is recommended that all monitor and alarm functions be integrated into a single operation.
1984-06-01
SEQUENTIAL TESTING (Bldg. A, Room C) 1300-1330 ’ 1330-1415 1415-1445 1445-1515 BREAK 1515-1545 A TRUNCATED SEQUENTIAL PROBABILITY RATIO TEST J...suicide optical data operational testing reliability random numbers bootstrap methods missing data sequential testing fire support complex computer model carcinogenesis studies EUITION Of 1 NOV 68 I% OBSOLETE a ...contributed papers can be ascertained from the titles of the
Heroic Reliability Improvement in Manned Space Systems
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
System reliability can be significantly improved by a strong continued effort to identify and remove all the causes of actual failures. Newly designed systems often have unexpected high failure rates which can be reduced by successive design improvements until the final operational system has an acceptable failure rate. There are many causes of failures and many ways to remove them. New systems may have poor specifications, design errors, or mistaken operations concepts. Correcting unexpected problems as they occur can produce large early gains in reliability. Improved technology in materials, components, and design approaches can increase reliability. The reliability growth is achieved by repeatedly operating the system until it fails, identifying the failure cause, and fixing the problem. The failure rate reduction that can be obtained depends on the number and the failure rates of the correctable failures. Under the strong assumption that the failure causes can be removed, the decline in overall failure rate can be predicted. If a failure occurs at the rate of lambda per unit time, the expected time before the failure occurs and can be corrected is 1/lambda, the Mean Time Before Failure (MTBF). Finding and fixing a less frequent failure with the rate of lambda/2 per unit time requires twice as long, time of 1/(2 lambda). Cutting the failure rate in half requires doubling the test and redesign time and finding and eliminating the failure causes.Reducing the failure rate significantly requires a heroic reliability improvement effort.
The advantages of the high voltage solar array for electric propulsion
NASA Technical Reports Server (NTRS)
Sater, B. L.
1973-01-01
The high voltage solar array offers improvements in efficiency, weight, and reliability for the electric propulsion power system. Conventional power processes and problems associated with ion thruster operation using SERT 2 experience are discussed and the advantages of the HVSA concept for electric propulsion are presented. Tests conducted operating the SERT 2 thruster system in conjunction with HVSA are reported. Thruster operation was observed to be normal and in some respects improved.
Practical Issues in Implementing Software Reliability Measurement
NASA Technical Reports Server (NTRS)
Nikora, Allen P.; Schneidewind, Norman F.; Everett, William W.; Munson, John C.; Vouk, Mladen A.; Musa, John D.
1999-01-01
Many ways of estimating software systems' reliability, or reliability-related quantities, have been developed over the past several years. Of particular interest are methods that can be used to estimate a software system's fault content prior to test, or to discriminate between components that are fault-prone and those that are not. The results of these methods can be used to: 1) More accurately focus scarce fault identification resources on those portions of a software system most in need of it. 2) Estimate and forecast the risk of exposure to residual faults in a software system during operation, and develop risk and safety criteria to guide the release of a software system to fielded use. 3) Estimate the efficiency of test suites in detecting residual faults. 4) Estimate the stability of the software maintenance process.
NASA Technical Reports Server (NTRS)
Dugala, Gina M.
2009-01-01
The U.S. Department of Energy (DOE), Lockheed Martin Space Company (LMSC), Sun power Inc., and NASA Glenn Research Center (GRC) have been developing an Advanced Stirling Radioisotope Generator (ASRG) for use as a power system on space science missions. This generator will make use of free-piston Stirling convertors to achieve higher conversion efficiency than currently available alternatives. NASA GRC's support of ASRG development includes extended operation testing of Advanced Stirling Convertors (ASCs) developed by Sunpower Inc. In the past year, NASA GRC has been building a test facility to support extended operation of a pair of engineering level ASCs. Operation of the convertors in the test facility provides convertor performance data over an extended period of time. Mechanical support hardware, data acquisition software, and an instrumentation rack were developed to prepare the pair of convertors for continuous extended operation. Short-term tests were performed to gather baseline performance data before extended operation was initiated. These tests included workmanship vibration, insulation thermal loss characterization, low-temperature checkout, and fUll-power operation. Hardware and software features are implemented to ensure reliability of support systems. This paper discusses the mechanical support hardware, instrumentation rack, data acquisition software, short-term tests, and safety features designed to support continuous unattended operation of a pair of ASCs.
NASA Astrophysics Data System (ADS)
Douglas, Erica Ann
Compound semiconductor devices, particularly those based on GaN, have found significant use in military and civilian systems for both microwave and optoelectronic applications. Future uses in ultra-high power radar systems will require the use of GaN transistors operated at very high voltages, currents and temperatures. GaN-based high electron mobility transistors (HEMTs) have proven power handling capability that overshadows all other wide band gap semiconductor devices for high frequency and high-power applications. Little conclusive research has been reported in order to determine the dominating degradation mechanisms of the devices that result in failure under standard operating conditions in the field. Therefore, it is imperative that further reliability testing be carried out to determine the failure mechanisms present in GaN HEMTs in order to improve device performance, and thus further the ability for future technologies to be developed. In order to obtain a better understanding of the true reliability of AlGaN/GaN HEMTs and determine the MTTF under standard operating conditions, it is crucial to investigate the interaction effects between thermal and electrical degradation. This research spans device characterization, device reliability, and device simulation in order to obtain an all-encompassing picture of the device physics. Initially, finite element thermal simulations were performed to investigate the effect of device design on self-heating under high power operation. This was then followed by a study of reliability of HEMTs and other tests structures during high power dc operation. Test structures without Schottky contacts showed high stability as compared to HEMTs, indicating that degradation of the gate is the reason for permanent device degradation. High reverse bias of the gate has been shown to induce the inverse piezoelectric effect, resulting in a sharp increase in gate leakage current due to crack formation. The introduction of elevated temperatures during high reverse gate bias indicated that device failure is due to the breakdown of an unintentional gate oxide. RF stress of AlGaN/GaN HEMTs showed comparable critical voltage breakdown regime as that of similar devices stressed under dc conditions. Though RF device characteristics showed stability up to a drain bias of 20 V, Schottky diode characteristics degraded substantially at all voltages investigated. Results from both dc and RF stress conditions, under several bias regimes, confirm that the primary root for stress induced degradation was due to the Schottky contact. (Full text of this dissertation may be available via the University of Florida Libraries web site. Please check http://www.uflib.ufl.edu/etd.html)
2011-05-01
Medical Institute’s publications Web site: www.faa.gov/library/reports/medical/oamtechreports i Technical Report Documentation Page 1. Report No. 2...Study One provided evidence of the reliability of the subtests, established performance norms for subjects with normal color vision ( NCV ) on each...Two provided evidence of the reliability of second operational ATCOV subtests, established performance norms for NCV subjects on each subtest
Data Applicability of Heritage and New Hardware For Launch Vehicle Reliability Models
NASA Technical Reports Server (NTRS)
Al Hassan, Mohammad; Novack, Steven
2015-01-01
Bayesian reliability requires the development of a prior distribution to represent degree of belief about the value of a parameter (such as a component's failure rate) before system specific data become available from testing or operations. Generic failure data are often provided in reliability databases as point estimates (mean or median). A component's failure rate is considered a random variable where all possible values are represented by a probability distribution. The applicability of the generic data source is a significant source of uncertainty that affects the spread of the distribution. This presentation discusses heuristic guidelines for quantifying uncertainty due to generic data applicability when developing prior distributions mainly from reliability predictions.
Reliability and commercialization of oxidized VCSEL
NASA Astrophysics Data System (ADS)
Li, Alice; Pan, Jin-Shan; Lai, Horng-Ching; Lee, Bor-Lin; Wu, Jack; Lin, Yung-Sen; Huo, Tai-Chan; Wu, Calvin; Huang, Kai-Feng
2003-06-01
The reliability of oxidized VCSEL has similar result to implanted VCSEL. This paper presents our work on reliability data of oxidized VCSEL device and also the comparison with implanted VCSEL. The MTTF of oxidized VCSEL is 2.73 x 106 hrs at 55°C, 6 mA and failure rate ~ 1 FITs for the first 2 years operation. The reliability data of oxidized VCSEL includes activation energy, MTTF (mean-time-to failure), failure rate prediction, and 85°C / 85% humidity test will be presented below. Commercialization of oxidized VCSEL is demonstrated such as VCSEL structure, manufacturing facility, and packaging. A cost effective approach is key to its success in applications such as Datacomm.
Reliability issues for a bolometer detector for ITER at high operating temperatures.
Meister, H; Kannamüller, M; Koll, J; Pathak, A; Penzel, F; Trautmann, T; Detemple, P; Schmitt, S; Langer, H
2012-10-01
The first detector prototypes for the ITER bolometer diagnostic featuring a 12.5 μm thick Pt-absorber have been realized and characterized in laboratory tests. The results show linear dependencies of the calibration parameters and are in line with measurements of prototypes with thinner absorbers. However, thermal cycling tests up to 450 °C of the prototypes with thick absorbers demonstrated that their reliability at these elevated operating temperatures is not yet sufficient. Profilometer measurements showed a deflection of the membrane hinting to stresses due to the deposition processes of the absorber. Finite element analysis (FEA) managed to reproduce the deflection and identified the highest stresses in the membrane in the region around the corners of the absorber. FEA was further used to identify changes in the geometry of the absorber with a positive impact on the intrinsic stresses of the membrane. However, further improvements are still necessary.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Xiangqi; Zhang, Yingchen
This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has beenmore » tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could actively tackle the voltage problem brought about by high penetrations of PV and improve the reliability of distribution system operation.« less
Accelerated testing of module-level power electronics for long-term reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
Accelerated testing of module-level power electronics for long-term reliability
Flicker, Jack David; Tamizhmani, Govindasamy; Moorthy, Mathan Kumar; ...
2016-11-10
This work has applied a suite of long-term-reliability accelerated tests to a variety of module-level power electronics (MLPE) devices (such as microinverters and optimizers) from five different manufacturers. This dataset is one of the first (only the paper by Parker et al. entitled “Dominant factors affecting reliability of alternating current photovoltaic modules,” in Proc. 42nd IEEE Photovoltaic Spec. Conf., 2015, is reported for reliability testing in the literature), as well as the largest, experimental sets in public literature, both in the sample size (five manufacturers including both dc/dc and dc/ac units and 20 units for each test) and the numbermore » of experiments (six different experimental test conditions) for MLPE devices. The accelerated stress tests (thermal cycling test per IEC 61215 profile, damp heat test per IEC 61215 profile, and static temperature tests at 100 and 125 °C) were performed under powered and unpowered conditions. The first independent long-term experimental data regarding damp heat and grid transient testing, as well as the longest term (>9 month) testing of MLPE units reported in the literature for thermal cycling and high-temperature operating life, are included in these experiments. Additionally, this work is the first to show in situ power measurements, as well as periodic efficiency measurements over a series of experimental tests, demonstrating whether certain tests result in long-term degradation or immediate catastrophic failures. Lastly, the result of this testing highlights the performance of MLPE units under the application of several accelerated environmental stressors.« less
Solar Refrigerator/Freezers For Vaccines
NASA Technical Reports Server (NTRS)
Ratajczak, Anthony F.
1988-01-01
Report presents results of field tests of solar-cell-powered refrigerator/freezers for vaccines. Covers following topics: explanation of project; descriptions of refrigerator/freezer systems; account of installation experiences; performance data for 22 systems for which field-test data reported; summary of operational reliability; comments of users of some systems tested; and recommendations for design and future use. Photovoltaic systems store vaccines in remote regions where powerlines unavailable.
Cold Regions - Environmental Testing of Individual Soldier Clothing
2011-10-17
Individual Soldier Clothing 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHORS 5d. PROJECT NUMBER 5e. TASK...This Test Operations Procedure (TOP) provides testing guidelines for individual Soldier cold weather clothing and footwear in a cold regions...Soldier clothing , along with its safety, reliability, durability, and performance when exposed to a cold regions environment. 15. SUBJECT TERMS
PV systems photoelectric parameters determining for field conditions and real operation conditions
NASA Astrophysics Data System (ADS)
Shepovalova, Olga V.
2018-05-01
In this work, research experience and reference documentation have been generalized related to PV systems photoelectric parameters (PV array output parameters) determining. The basic method has been presented that makes it possible to determine photoelectric parameters with the state-of-the-art reliability and repeatability. This method provides an effective tool for PV systems comparison and evaluation of PV system parameters that the end-user will have in the course of its real operation for compliance with those stipulated in reference documentation. The method takes in consideration all parameters that may possibly affect photoelectric performance and that are supported by sufficiently valid procedures for their values testing. Test conditions, requirements for equipment subject to tests and test preparations have been established and the test procedure for fully equipped PV system in field tests and in real operation conditions has been described.
Performance test results of 80 K centrifugal compressor for helium refrigerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asakura, H.; Kato, D.; Saji, N.
1994-12-31
The authors have developed a completely oil-free compressor used for the highly reliable helium refrigeration system for a superconducting generator and carried out performance tests under actual condition. The compressor is designed to achieve a pressure ratio of 8 with only 4 stages by cooling the compressor inlet at 80 K with liquid nitrogen, thus acquiring high reliability of long-term maintenance-free operation together with the use of magnetic bearings for oil-free operation. The compressor at each stage is independently driven by a 25 kW built-in motor at the speed of 100,000 rpm, with the power supplied by a variable frequencymore » inverter. The performance test was carried out at each stage, by incorporating the compressor in the closed loop test equipment using helium gas. It was recognized from the test results that the specified pressure ratio of each stage was achieved at the speed below the rated one of 100,000 rpm. It was found that each stage of the compressor has a flat characteristics of adiabatic efficiency over the wide flow range. The mechanical rotation characteristics at low temperatures was also confirmed to be sufficiently stable.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, Phillip A.; O'Hagan, Ryan; Shumaker, Brent
The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of online monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carriedmore » out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I&C aging management goals of the Department of Energy and long-time operation of ATR.« less
Jácome, Cristina; Cruz, Joana; Oliveira, Ana; Marques, Alda
2016-11-01
The Berg Balance Scale (BBS), Balance Evaluation Systems Test (BESTest), Mini-BESTest, and Brief-BESTest are useful in the assessment of balance. Their psychometric properties, however, have not been tested in patients with chronic obstructive pulmonary disease (COPD). This study aimed to compare the validity, reliability, and ability to identify fall status of the BBS, BESTest, Mini-BESTest, and the Brief-BESTest in patients with COPD. A cross-sectional study was conducted. Forty-six patients (24 men, 22 women; mean age=75.9 years, SD=7.1) were included. Participants were asked to report their falls during the previous 12 months and to fill in the Activity-specific Balance Confidence (ABC) Scale. The BBS and the BESTest were administered. Mini-BESTest and Brief-BESTest scores were computed based on the participants' BESTest performance. Validity was assessed by correlating balance tests with each other and with the ABC Scale. Interrater reliability (2 raters), intrarater reliability (48-72 hours), and minimal detectable changes (MDCs) were established. Receiver operating characteristics assessed the ability of each balance test to differentiate between participants with and without a history of falls. Balance test scores were significantly correlated with each other (Spearman correlation rho=.73-.90) and with the ABC Scale (rho=.53-.75). Balance tests presented high interrater reliability (intraclass correlation coefficient [ICC]=.85-.97) and intrarater reliability (ICC=.52-.88) and acceptable MDCs (MDC=3.3-6.3 points). Although all balance tests were able to identify fall status (area under the curve=0.74-0.84), the BBS (sensitivity=73%, specificity=77%) and the Brief-BESTest (sensitivity=81%, specificity=73%) had the higher ability to identify fall status. Findings are generalizable mainly to older patients with moderate COPD. The 4 balance tests are valid, reliable, and valuable in identifying fall status in patients with COPD. The Brief-BESTest presented slightly higher interrater reliability and ability to differentiate participants' fall status. © 2016 American Physical Therapy Association.
Latvala, E; Saranto, K; Pekkala, E
2004-10-01
The main purpose of the project was to develop computerized instruments that could be used by nurses and patients to assess their cooperation and mutual contributions to care. This paper presents a part of the project: the reliability and validity testing phase of a process of instrument development. To test the validity and reliability of the instruments, data were collected with questionnaires from nurses (n = 146) and patients (n = 286). The validity evaluated as construct validity and the reliability evaluated as internal consistency of the instruments were quite good. Construct validity was tested by factor analysis, and internal consistency was tested by Cronbach's alpha coefficient, which varied from 0.69 to 0.79. The instruments, which consisted of a software application that can be operated in a www environment, were meant to be used as tools in the psychiatric nursing context for assessing the cooperation between the nurses and patients and the patient's participation in his/her care. Furthermore, the computer programme can be used as a tool for developing and assessing the patient orientation in nursing.
Frequency doubled high-power disk lasers in pulsed and continuous-wave operation
NASA Astrophysics Data System (ADS)
Weiler, Sascha; Hangst, Alexander; Stolzenburg, Christian; Zawischa, Ivo; Sutter, Dirk; Killi, Alexander; Kalfhues, Steffen; Kriegshaeuser, Uwe; Holzer, Marco; Havrilla, David
2012-03-01
The disk laser with multi-kW output power in infrared cw operation is widely used in today's manufacturing, primarily in the automotive industry. The disk technology combines high power (average and/or peak power), excellent beam quality, high efficiency and high reliability with low investment and operating costs. Additionally, the disk laser is ideally suited for frequency conversion due to its polarized output with negligible depolarization losses. Laser light in the green spectral range (~515 nm) can be created with a nonlinear crystal. Pulsed disk lasers with green output of well above 50 W (extracavity doubling) in the ps regime and several hundreds of Watts in the ns regime with intracavity doubling are already commercially available whereas intracavity doubled disk lasers in continuous wave operation with greater than 250 W output are in test phase. In both operating modes (pulsed and cw) the frequency doubled disk laser offers advantages in existing and new applications. Copper welding for example is said to show much higher process reliability with green laser light due to its higher absorption in comparison to the infrared. This improvement has the potential to be very beneficial for the automotive industry's move to electrical vehicles which requires reliable high-volume welding of copper as a major task for electro motors, batteries, etc.
Nuclear fuel performance: Trends, remedies and challenges
NASA Astrophysics Data System (ADS)
Rusch, C. A.
2008-12-01
It is unacceptable to have nuclear power plants unavailable or power restricted due to fuel reliability issues. 'Fuel reliability' has a much broader definition than just maintaining mechanical integrity and being leaker free - fuel must fully meet the specifications, impose no adverse impacts on plant operation and safety, and maintain quantifiable margins within design and operational envelopes. The fuel performance trends over the last decade are discussed and the significant contributors to reduced reliability experienced with commercial PWR and BWR designs are identified and discussed including grid-to-rod fretting and debris fretting in PWR designs and accelerated corrosion, debris fretting and pellet-cladding interaction in BWR designs. In many of these cases, the impacts have included not only fuel failures but also plant operating restrictions, forced shutdowns, and/or enhanced licensing authority oversight. Design and operational remedies are noted. The more demanding operating regimes and the constant quest to improve fuel performance require enhancements to current designs and/or new design features. Fuel users must continue to and enhance interaction with fuel suppliers in such areas as oversight of supplier design functions, lead test assembly irradiation programs and quality assurance oversight and surveillance. With the implementation of new designs and/or features, such fuel user initiatives can help to minimize the potential for performance problems.
Vijaya, Gopalan; Cartwright, Rufus; Bhide, Alka; Derpapas, Alexandros; Fernando, Ruwan; Khullar, Vik
2016-11-01
The validity and reliability of measurement of urinary NGF as a diagnostic biomarker in women with lower urinary tract dysfunction (LUTD) is uncertain. We aimed to evaluate both the diagnostic and discriminant validity, and the test-retest reliability of urinary NGF measurement in women with LUTD. Urinary NGF was measured in women with LUTD (n = 205) and asymptomatic subjects (n = 31). Urinary NGF was assayed using an ELISA method and normalized against urinary creatinine. NGF/creatinine ratios were compared between symptom subgroups using Mann-Whitney U test, and between different urodynamic diagnoses using the Kruskal-Wallis test. Receiver Operator Characteristic (ROC) analysis was employed to evaluate the diagnostic performance of urinary NGF. Test-retest reliability of NGF measurement was assessed using intra-class correlation (ICC). Urinary NGF was significantly but non-specifically increased in symptomatic patients when compared to controls (13.33 vs. 2.05 ng NGF/g Cr, P < 0.001). On multivariate logistic regression NGF was a good predictor of patients having OAB or not, however, the adjusted odds ratio only 1.006. ROC analysis demonstrated poor discriminant ability between different symptomatic groups and urodynamic groups. Using a cut off of 13.0 ng NGF/g creatinine the test provides a sensitivity of 81%, but a specificity of only 39% for overactive bladder. The assays demonstrated good test-retest reliability with ICC of 0.889. Although urinary NGF can be reliably assayed, and is increased in various LUTDs, it discriminates poorly between these disorders therefore has very limited potential as a biomarker. Neurourol. Urodynam. 35:944-948, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Design, fabrication, and operation of a test rig for high-speed tapered-roller bearings
NASA Technical Reports Server (NTRS)
Signer, H. R.
1974-01-01
A tapered-roller bearing test machine was designed, fabricated and successfully operated at speeds to 20,000 rpm. Infinitely variable radial loads to 26,690 N (6,000 lbs.) and thrust loads to 53,380 N (12,000 lbs.) can be applied to test bearings. The machine instrumentation proved to have the accuracy and reliability required for parametric bearing performance testing and has the capability of monitoring all programmed test parameters at continuous operation during life testing. This system automatically shuts down a test if any important test parameter deviates from the programmed conditions, or if a bearing failure occurs. A lubrication system was developed as an integral part of the machine, capable of lubricating test bearings by external jets and by means of passages feeding through the spindle and bearing rings into the critical internal bearing surfaces. In addition, provisions were made for controlled oil cooling of inner and outer rings to effect the type of bearing thermal management that is required when testing at high speeds.
Power processor for a 30cm ion thruster
NASA Technical Reports Server (NTRS)
Biess, J. J.; Inouye, L. Y.
1974-01-01
A thermal vacuum power processor for the NASA Lewis 30cm Mercury Ion Engine was designed, fabricated and tested to determine compliance with electrical specifications. The power processor breadboard used the silicon controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to an ion engine. The power processor includes a digital interface unit to process all input commands and internal telemetry signals so that operation is compatible with a central computer system. The breadboard was tested in a thermal vacuum environment. Integration tests were performed with the ion engine and demonstrate operational compatibility and reliable operation without any component failures. Electromagnetic interference data were also recorded on the design to provide information on the interaction with total spacecraft.
NASA Astrophysics Data System (ADS)
Pattalwar, Shrikant; Jones, Thomas; Strachan, John; Bate, Robert; Davies, Phil; McIntosh, Peter
2012-06-01
Through an international cryomodule collaboration, ASTeC at Daresbury Laboratory has taken the primary responsibility in leading the development of an optimised Superconducting RF (SRF) cryomodule, operating in CW mode for energy recovery facilities and other high duty cycle accelerators. For high beam current operation, Higher Order Mode (HOM) absorbers are critical components of the SRF Cryomodule, ensuring excessive heating of the accelerating structures and beam instabilities are effectively managed. This paper describes some of the cold tests conducted on the HOM absorbers and other critical components during the construction phase, to ensure that the quality and reliable cryomodule performance is maintained.
Experimental operation of a sodium heat pipe
NASA Astrophysics Data System (ADS)
Holtz, R. E.; McLennan, G. A.; Koehl, E. R.
1985-05-01
This report documents the operation of a 28 in. long sodium heat pipe in the Heat Pipe Test Facility (HPTF) installed at Argonne National Laboratory. Experimental data were collected to simulate conditions prototypic of both a fluidized bed coal combustor application and a space environment application. Both sets of experiment data show good agreement with the heat pipe analytical model. The heat transfer performance of the heat pipe proved reliable over a substantial period of operation and over much thermal cycling. Additional testing of longer heat pipes under controlled laboratory conditions will be necessary to determine performance limitations and to complete the design code validation.
Mechanization of and experience with a triplex fly-by-wire backup control system
NASA Technical Reports Server (NTRS)
Lock, W. P.; Petersen, W. R.; Whitman, G. B.
1976-01-01
A redundant three axis analog control system was designed and developed to back up a digital fly by wire control system for an F-8C airplane. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum displacement (force) side stick. The operational reliability of the F-8 digital fly by wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.
NASA Technical Reports Server (NTRS)
Phoenix, S. Leigh; Kezirian, Michael T.; Murthy, Pappu L. N.
2009-01-01
Composite Overwrapped Pressure Vessels (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Flight certification is dependent on the reliability analysis to quantify the risk of stress rupture failure in existing flight vessels. Full certification of this reliability model would require a statistically significant number of lifetime tests to be performed and is impractical given the cost and limited flight hardware for certification testing purposes. One approach to confirm the reliability model is to perform a stress rupture test on a flight COPV. Currently, testing of such a Kevlar49 (Dupont)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the database and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio model is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one "nine," that is, reducing the predicted probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several vessels would be necessary.
14 CFR 33.91 - Engine system and component tests.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., reliability, and durability. (c) Each unpressurized hydraulic fluid tank may not fail or leak when subjected... minimum operating values. [Doc. No. 3025, 29 FR 7453, June 10, 1964, as amended by Amdt. 33-6, 39 FR 35469...
Stormwater and Wastewater Infrastructure Monitoring Test Bed
The growing application of stormwater and wastewater management in urban and urbanizing environments is increasing the demand for monitoring technologies and systems that can provide reliable performance data, in real-time or near real-time, for operation and maintenance decision...
DOT National Transportation Integrated Search
1998-09-01
Emissions Management Using ITS Technology report summarizes and interprets the results of three Intelligent Transportation Systems (ITS) Field Operational Tests (FOTs) that evaluated the use of emerging technologies to help authorities measure emissi...
Design-for-reliability (DfR) of aerospace electronics: Attributes and challenges
NASA Astrophysics Data System (ADS)
Bensoussan, A.; Suhir, E.
The next generation of multi-beam satellite systems that would be able to provide effective interactive communication services will have to operate within a highly flexible architecture. One option to develop such flexibility is to employ microwaves and/or optoelectronic components and to make them reliable. The use of optoelectronic devices, equipments and systems will result indeed in significant improvement in the state-of-the-art only provided that the new designs will suggest a novel and effective architecture that will combine the merits of good functional performance, satisfactory mechanical (structural) reliability and high cost effectiveness. The obvious challenge is the ability to design and fabricate equipment based on EEE components that would be able to successfully withstand harsh space environments for the entire duration of the mission. It is imperative that the major players in the space industry, such as manufacturers, industrial users, and space agencies, understand the importance and the limits of the achievable quality and reliability of optoelectronic devices operated in harsh environments. It is equally imperative that the physics of possible failures is well understood and, if necessary, minimized, and that adequate Quality Standards are developed and employed. The space community has to identify and to develop the strategic approach for validating optoelectronic products. This should be done with consideration of numerous intrinsic and extrinsic requirements for the systems' performance. When considering a particular next generation optoelectronic space system, the space community needs to address the following major issues: proof of concept for this system, proof of reliability and proof of performance. This should be done with taking into account the specifics of the anticipated application. High operational reliability cannot be left to the prognostics and health monitoring/management (PHM) effort and stage, no matter how important and - ffective such an effort might be. Reliability should be pursued at all the stages of the equipment lifetime: design, product development, manufacturing, burn-in testing and, of course, subsequent PHM after the space apparatus is launched and operated.
Continuously Regenerable Freeze-Out CO2 Control Technology
NASA Technical Reports Server (NTRS)
Fricker, John; Dyer, Chris; Myers, Jeff; Patten, Rich; Paul, Heather
2007-01-01
Carbon dioxide (CO2) removal technology development for portable life support systems (PLSS) has traditionally concentrated in the areas of solid and liquid chemical sorbents and semi-permeable membranes. Most of these systems are too heavy in gravity environments, require prohibitive amounts of consumables for operation on long term planetary missions, or are inoperable on the surface of Mars due to the presence of a CO2 atmosphere. This paper describes the effort performed to mature an innovative CO2 removal technology that meets NASA s planetary mission needs while adhering to the important guiding principles of simplicity, reliability, and operability. A breadboard cryogenic carbon dioxide scrubber (Cryo Scrubber) for a closed loop cryogenic PLSS was developed, designed, and tested, and a conceptual design suitable for a PLSS was developed based on the results of the breadboard testing. The Cryo Scrubber freezes CO2 and other trace contaminants out of expired vent loop gas using cooling available from a liquid oxygen (LOX) based PLSS. The device is continuously regenerable, with solid CO2 being removed from the cold freeze-out surfaces, sublimated, and vented overboard. Duration is limited only by the supply of LOX stored in the PLSS. Simplicity, reliability, and operability are universally important criteria for critical hardware on long duration Lunar or Mars missions. The Cryo Scrubber has no moving parts, requires no additional consumables, and uses no electrical power, contributing to its simplicity and reliability. It is easy to use; no operator action is required to prepare, use, or shut down the Cryo Scrubber, and it does not require charging or regeneration. The versatility of the concept allows for operation on earth, the moon, and Mars, and in microgravity.
NASA Technical Reports Server (NTRS)
Hebert, Phillip W.
2008-01-01
NASA/SSC's Mission in Rocket Propulsion Testing Is to Acquire Test Performance Data for Verification, Validation and Qualification of Propulsion Systems Hardware: Accurate, Reliable, Comprehensive, and Timely. Data Acquisition in a Rocket Propulsion Test Environment Is Challenging: a) Severe Temporal Transient Dynamic Environments; b) Large Thermal Gradients; c) Vacuum to high pressure regimes. A-3 Test Stand Development is equally challenging with respect to accommodating vacuum environment, operation of a CSG system, and a large quantity of data system and control channels to determine proper engine performance as well as Test Stand operation. SSC is currently in the process of providing modernized DAS, Control Systems, Video, and network systems for the A-3 Test Stand to overcome these challenges.
Catalytic ignition of hydrogen and oxygen propellants
NASA Technical Reports Server (NTRS)
Zurawski, Robert L.; Green, James M.
1988-01-01
An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen propellants. Shell 405 granular catalyst and a monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant temperature, and back pressure were varied parametrically in testing to determine the operational limits of the catalytic igniter. The test results show that the gaseous hydrogen and oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. A cyclic life of nearly 2000, 2 sec pulses at nominal operating conditions was demonstrated with the catalytic igniter. The results of the experimental program and the established operational limits for a catalytic igniter using the Shell 405 catalysts are presented.
Catalytic ignition of hydrogen and oxygen propellants
NASA Technical Reports Server (NTRS)
Zurawski, Robert L.; Green, James M.
1988-01-01
An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen propellants. Shell 405 granular catalyst and a monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant temperature, and back pressure were varied parametrically in testing to determine the operational limits of the catalytic igniter. The test results show that the gaseous hydrogen and oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. A cyclic life of nearly 2000, 2 sec pulses at nominal operating conditions was demonstrated with the catalytic igniter. The results of the experimental program and the established operational limits for a catalytic igniter using the Shell 405 catalyst are presented.
The Application of Surface Potential Test on Hand-making Insulation for Generator Stator End-winding
NASA Astrophysics Data System (ADS)
Lu, Zhu-mao; Liu, Qing; Wang, Tian-zheng; Bai, Lu; Li, Yan-peng
2017-05-01
This paper presents the advantage of surface potential test on hand-making insulation for generator stator end-winding insulation detection, compared with DC or AC withstand voltage test, also details the test principle, connection method and test notes. And through the case, surface potential test on hand-making insulation proved effective for insulation quality detection after generator stator end-winding maintenance, and the experimental data is useful and reliable for the electrical equipment operation and maintenance in the power plant.
An integrated approach to system design, reliability, and diagnosis
NASA Technical Reports Server (NTRS)
Patterson-Hine, F. A.; Iverson, David L.
1990-01-01
The requirement for ultradependability of computer systems in future avionics and space applications necessitates a top-down, integrated systems ingeneering approach for design, implementation, testing, and operation. The functional analyses of hardware and software systems must be combined by models that are flexible enough to represent their interactions and behavior. The information contained in these models must be accessible throughout all phases of the system life cycle in order to maintain consistency and accuracy in design and operational decisions. One approach being taken by researchers at Ames Research Center is the creation of an object-oriented environment that integrates information about system components required in the reliability evaluation with behavioral information useful for diagnostic algorithms.
NASA Astrophysics Data System (ADS)
Wan, Fubin; Tan, Yuanyuan; Jiang, Zhenhua; Chen, Xun; Wu, Yinong; Zhao, Peng
2017-12-01
Lifetime and reliability are the two performance parameters of premium importance for modern space Stirling-type pulse tube refrigerators (SPTRs), which are required to operate in excess of 10 years. Demonstration of these parameters provides a significant challenge. This paper proposes a lifetime prediction and reliability estimation method that utilizes accelerated degradation testing (ADT) for SPTRs related to gaseous contamination failure. The method was experimentally validated via three groups of gaseous contamination ADT. First, the performance degradation model based on mechanism of contamination failure and material outgassing characteristics of SPTRs was established. Next, a preliminary test was performed to determine whether the mechanism of contamination failure of the SPTRs during ADT is consistent with normal life testing. Subsequently, the experimental program of ADT was designed for SPTRs. Then, three groups of gaseous contamination ADT were performed at elevated ambient temperatures of 40 °C, 50 °C, and 60 °C, respectively and the estimated lifetimes of the SPTRs under normal condition were obtained through acceleration model (Arrhenius model). The results show good fitting of the degradation model with the experimental data. Finally, we obtained the reliability estimation of SPTRs through using the Weibull distribution. The proposed novel methodology enables us to take less than one year time to estimate the reliability of the SPTRs designed for more than 10 years.
Revalidation of the NASA Ames 11-by 11-Foot Transonic Wind Tunnel with a Commercial Airplane Model
NASA Technical Reports Server (NTRS)
Kmak, Frank J.; Hudgins, M.; Hergert, D.; George, Michael W. (Technical Monitor)
2001-01-01
The 11-By 11-Foot Transonic leg of the Unitary Plan Wind Tunnel (UPWT) was modernized to improve tunnel performance, capability, productivity, and reliability. Wind tunnel tests to demonstrate the readiness of the tunnel for a return to production operations included an Integrated Systems Test (IST), calibration tests, and airplane validation tests. One of the two validation tests was a 0.037-scale Boeing 777 model that was previously tested in the 11-By 11-Foot tunnel in 1991. The objective of the validation tests was to compare pre-modernization and post-modernization results from the same airplane model in order to substantiate the operational readiness of the facility. Evaluation of within-test, test-to-test, and tunnel-to-tunnel data repeatability were made to study the effects of the tunnel modifications. Tunnel productivity was also evaluated to determine the readiness of the facility for production operations. The operation of the facility, including model installation, tunnel operations, and the performance of tunnel systems, was observed and facility deficiency findings generated. The data repeatability studies and tunnel-to-tunnel comparisons demonstrated outstanding data repeatability and a high overall level of data quality. Despite some operational and facility problems, the validation test was successful in demonstrating the readiness of the facility to perform production airplane wind tunnel%, tests.
Raytheon advanced pulse-tube cryocoolers
NASA Astrophysics Data System (ADS)
Conrad, Ted; Yates, Ryan; Kuo, Daniel; Schaefer, Brian; Arnoult, Matt
2016-05-01
Since the 1970s, Raytheon has developed, built, tested and integrated high performance cryocoolers. Our versatile designs for single and multi-stage cryocoolers provide reliable operation for temperatures from 10 to 200 Kelvin with power levels ranging from 50 W to nearly 600 W. These cryocoolers incorporate clearance seals, flexure suspensions, hermetic housings and dynamic balancing to provide long service life and reliable operation in all relevant environments. Recently, Raytheon has developed an advanced regenerator technology capable of operating efficiently at high frequencies and outperforming traditional screen regenerators. The Raytheon Advanced Miniature (RAM-100) cryocooler, a flight packaged, high frequency, single stage pulse tube cooler with an integrated surge volume and inertance tube, has been designed for use with this regenerator. Design details and experimentally measured performance of two iterations of the RAM cryocooler are presented in this paper.
Optimization of a PCRAM Chip for high-speed read and highly reliable reset operations
NASA Astrophysics Data System (ADS)
Li, Xiaoyun; Chen, Houpeng; Li, Xi; Wang, Qian; Fan, Xi; Hu, Jiajun; Lei, Yu; Zhang, Qi; Tian, Zhen; Song, Zhitang
2016-10-01
The widely used traditional Flash memory suffers from its performance limits such as its serious crosstalk problems, and increasing complexity of floating gate scaling. Phase change random access memory (PCRAM) becomes one of the most potential nonvolatile memories among the new memory techniques. In this paper, a 1M-bit PCRAM chip is designed based on the SMIC 40nm CMOS technology. Focusing on the read and write performance, two new circuits with high-speed read operation and highly reliable reset operation are proposed. The high-speed read circuit effectively reduces the reading time from 74ns to 40ns. The double-mode reset circuit improves the chip yield. This 1M-bit PCRAM chip has been simulated on cadence. After layout design is completed, the chip will be taped out for post-test.
NASA Astrophysics Data System (ADS)
Kammel, H.; Haase, H.
An experimental psycho-physiological method is presented for the evaluation of visual-cognitive performance preconditions and operational reliability of pilots and cosmonauts. As visual-cognitive stress are used tachistoscopically presented instrument symbols under conditions of individual speed of work and time pressure. The results of the compared extreme groups consisting of pilots with good and insufficient flight performance showed that the pilots with impairments to the quality of flight activity differ already before the test in their individual habitual characteristics and actual motivation, during the stress in their operational parameters, in the dimensions of their cardiorespiratory activation as well as in their efficiency and after the stress in their subjective experience of the stress. Conclusions are drawn for the evaluation of the aptitude of pilots and cosmonauts.
Reliability Considerations for the Operation of Large Accelerator User Facilities
Willeke, F. J.
2016-01-29
The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.
An integrated approach to system design, reliability, and diagnosis
NASA Technical Reports Server (NTRS)
Patterson-Hine, F. A.; Iverson, David L.
1990-01-01
The requirement for ultradependability of computer systems in future avionics and space applications necessitates a top-down, integrated systems engineering approach for design, implementation, testing, and operation. The functional analyses of hardware and software systems must be combined by models that are flexible enough to represent their interactions and behavior. The information contained in these models must be accessible throughout all phases of the system life cycle in order to maintain consistency and accuracy in design and operational decisions. One approach being taken by researchers at Ames Research Center is the creation of an object-oriented environment that integrates information about system components required in the reliability evaluation with behavioral information useful for diagnostic algorithms. Procedures have been developed at Ames that perform reliability evaluations during design and failure diagnoses during system operation. These procedures utilize information from a central source, structured as object-oriented fault trees. Fault trees were selected because they are a flexible model widely used in aerospace applications and because they give a concise, structured representation of system behavior. The utility of this integrated environment for aerospace applications in light of our experiences during its development and use is described. The techniques for reliability evaluation and failure diagnosis are discussed, and current extensions of the environment and areas requiring further development are summarized.
NASA Astrophysics Data System (ADS)
Stamenkovic, Dragan D.; Popovic, Vladimir M.
2015-02-01
Warranty is a powerful marketing tool, but it always involves additional costs to the manufacturer. In order to reduce these costs and make use of warranty's marketing potential, the manufacturer needs to master the techniques for warranty cost prediction according to the reliability characteristics of the product. In this paper a combination free replacement and pro rata warranty policy is analysed as warranty model for one type of light bulbs. Since operating conditions have a great impact on product reliability, they need to be considered in such analysis. A neural network model is used to predict light bulb reliability characteristics based on the data from the tests of light bulbs in various operating conditions. Compared with a linear regression model used in the literature for similar tasks, the neural network model proved to be a more accurate method for such prediction. Reliability parameters obtained in this way are later used in Monte Carlo simulation for the prediction of times to failure needed for warranty cost calculation. The results of the analysis make possible for the manufacturer to choose the optimal warranty policy based on expected product operating conditions. In such a way, the manufacturer can lower the costs and increase the profit.
An integrated approach to system design, reliability, and diagnosis
NASA Astrophysics Data System (ADS)
Patterson-Hine, F. A.; Iverson, David L.
1990-12-01
The requirement for ultradependability of computer systems in future avionics and space applications necessitates a top-down, integrated systems engineering approach for design, implementation, testing, and operation. The functional analyses of hardware and software systems must be combined by models that are flexible enough to represent their interactions and behavior. The information contained in these models must be accessible throughout all phases of the system life cycle in order to maintain consistency and accuracy in design and operational decisions. One approach being taken by researchers at Ames Research Center is the creation of an object-oriented environment that integrates information about system components required in the reliability evaluation with behavioral information useful for diagnostic algorithms. Procedures have been developed at Ames that perform reliability evaluations during design and failure diagnoses during system operation. These procedures utilize information from a central source, structured as object-oriented fault trees. Fault trees were selected because they are a flexible model widely used in aerospace applications and because they give a concise, structured representation of system behavior. The utility of this integrated environment for aerospace applications in light of our experiences during its development and use is described. The techniques for reliability evaluation and failure diagnosis are discussed, and current extensions of the environment and areas requiring further development are summarized.
An Initiative Toward Reliable Long-Duration Operation of Diode Lasers in Space
NASA Technical Reports Server (NTRS)
Tratt, David M.; Amzajerdian, Farzin; Stephen, Mark A.; Shapiro, Andrew A.
2006-01-01
This viewgraph presentation reviews the workings of the Laser Diode Arrays (LDA) working group. The group facilitates focused interaction between the LDA user and provider communities and it will author standards document for the specification and qualification of LDA's for operation in the space environment. It also reviews the NASA test and evaluation facilities that are available to the community.
Using Facility Condition Assessments to Identify Actions Related to Infrastructure
NASA Technical Reports Server (NTRS)
Rubert, Kennedy F.
2010-01-01
To support cost effective, quality research it is essential that laboratory and testing facilities are maintained in a continuous and reliable state of availability at all times. NASA Langley Research Center (LaRC) and its maintenance contractor, Jacobs Technology, Inc. Research Operations, Maintenance, and Engineering (ROME) group, are in the process of implementing a combined Facility Condition Assessment (FCA) and Reliability Centered Maintenance (RCM) program to improve asset management and overall reliability of testing equipment in facilities such as wind tunnels. Specific areas are being identified for improvement, the deferred maintenance cost is being estimated, and priority is being assigned against facilities where conditions have been allowed to deteriorate. This assessment serves to assist in determining where to commit available funds on the Center. RCM methodologies are being reviewed and enhanced to assure that appropriate preventive, predictive, and facilities/equipment acceptance techniques are incorporated to prolong lifecycle availability and assure reliability at minimum cost. The results from the program have been favorable, better enabling LaRC to manage assets prudently.
Reliability Testing Using the Vehicle Durability Simulator
2017-11-20
remote parameter control (RPC) software. The software is specifically designed for the data collection, analysis, and simulation processes outlined in...4516. 3. TOP 02-2-505 Inspection and Preliminary Operation of Vehicles, 4 February 1987. 4. Multi-Shaker Test and Control : Design , Test, and...currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 20-11-2017 2. REPORT
General test plan redundant sensor strapdown IMU evaluation program
NASA Technical Reports Server (NTRS)
Hartwell, T.; Irwin, H. A.; Miyatake, Y.; Wedekind, D. E.
1971-01-01
The general test plan for a redundant sensor strapdown inertial measuring unit evaluation program is presented. The inertial unit contains six gyros and three orthogonal accelerometers. The software incorporates failure detection and correction logic and a land vehicle navigation program. The principal objective of the test is a demonstration of the practicability, reliability, and performance of the inertial measuring unit with failure detection and correction in operational environments.
Technology verification phase. Dynamic isotope power system. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halsey, D.G.
1982-03-10
The Phase I requirements of the Kilowatt Isotope Power System (KIPS) program were to make a detailed Flight System Conceptual Design (FSCD) for an isotope fueled organic Rankine cycle power system and to build and test a Ground Demonstration System (GDS) which simulated as closely as possible the operational characteristics of the FSCD. The activities and results of Phase II, the Technology Verification Phase, of the program are reported. The objectives of this phase were to increase system efficiency to 18.1% by component development, to demonstrate system reliability by a 5000 h endurance test and to update the flight systemmore » design. During Phase II, system performance was improved from 15.1% to 16.6%, an endurance test of 2000 h was performed while the flight design analysis was limited to a study of the General Purpose Heat Source, a study of the regenerator manufacturing technique and analysis of the hardness of the system to a laser threat. It was concluded from these tests that the GDS is basically prototypic of a flight design; all components necessary for satisfactory operation were demonstrated successfully at the system level; over 11,000 total h of operation without any component failure attested to the inherent reliability of this type of system; and some further development is required, specifically in the area of performance. (LCL)« less
Manzi, Luigi; Villafañe, Jorge Hugo; Indino, Cristian; Tamini, Jacopo; Berjano, Pedro; Usuelli, Federico Giuseppe
2017-11-08
The purpose of this study was to investigate the test-retest reliability of the Phi angle in patients undergoing total ankle replacement (TAR) for end stage ankle osteoarthritis (OA) to assess the rotational alignment of the talar component. Retrospective observational cross-sectional study of prospectively collected data. Post-operative anteroposterior radiographs of the foot of 170 patients who underwent TAR for the ankle OA were evaluated. Three physicians measured Phi on the 170 randomly sorted and anonymized radiographs on two occasions, one week apart (test and retest conditions), inter and intra-observer agreement were evaluated. Test-retest reliability of Phi angle measurement was excellent for patients with Hintegra TAR (ICC=0.995; p<0.001) and Zimmer TAR (ICC=0.995; p<0.001) on radiographs of subjects with ankle OA. There were no significant differences in the reliability of the Phi angle measurement between patients with Hintegra vs. Zimmer implants (p>0.05). Measurement of Phi angle on weight-bearing dorsoplantar radiograph showed an excellent reliability among orthopaedic surgeons in determining the position of the talar component in the axial plane. Level II, cross sectional study. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Eppler, Dean B.
2013-01-01
The scientific success of any future human lunar exploration mission will be strongly dependent on design of both the systems and operations practices that underpin crew operations on the lunar surface. Inept surface mission preparation and design will either ensure poor science return, or will make achieving quality science operation unacceptably difficult for the crew and the mission operations and science teams. In particular, ensuring a robust system for managing real-time science information flow during surface operations, and ensuring the crews receive extensive field training in geological sciences, are as critical to mission success as reliable spacecraft and a competent operations team.
Effect of Random Thermal Spikes on Stirling Convertor Heater Head Reliability
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Korovaichuk, Igor; Halford, Gary R.
2004-01-01
Onboard radioisotope power systems being developed to support future NASA exploration missions require reliable design lifetimes of up to 14 yr and beyond. The structurally critical heater head of the high-efficiency developmental Stirling power convertor has undergone extensive computational analysis of operating temperatures (up to 650 C), stresses, and creep resistance of the thin-walled Inconel 718 bill of material. Additionally, assessment of the effect of uncertainties in the creep behavior of the thin-walled heater head, the variation in the manufactured thickness, variation in control temperature, and variation in pressure on the durability and reliability were performed. However, it is possible for the heater head to experience rare incidences of random temperature spikes (excursions) of short duration. These incidences could occur randomly with random magnitude and duration during the desired mission life. These rare incidences could affect the creep strain rate and therefore the life. The paper accounts for these uncertainties and includes the effect of such rare incidences, random in nature, on the reliability. The sensitivities of variables affecting the reliability are quantified and guidelines developed to improve the reliability are outlined. Furthermore, the quantified reliability is being verified with test data from the accelerated benchmark tests being conducted at the NASA Glenn Research Center.
Fundamentals of endoscopic surgery: creation and validation of the hands-on test.
Vassiliou, Melina C; Dunkin, Brian J; Fried, Gerald M; Mellinger, John D; Trus, Thadeus; Kaneva, Pepa; Lyons, Calvin; Korndorffer, James R; Ujiki, Michael; Velanovich, Vic; Kochman, Michael L; Tsuda, Shawn; Martinez, Jose; Scott, Daniel J; Korus, Gary; Park, Adrian; Marks, Jeffrey M
2014-03-01
The Fundamentals of Endoscopic Surgery™ (FES) program consists of online materials and didactic and skills-based tests. All components were designed to measure the skills and knowledge required to perform safe flexible endoscopy. The purpose of this multicenter study was to evaluate the reliability and validity of the hands-on component of the FES examination, and to establish the pass score. Expert endoscopists identified the critical skill set required for flexible endoscopy. They were then modeled in a virtual reality simulator (GI Mentor™ II, Simbionix™ Ltd., Airport City, Israel) to create five tasks and metrics. Scores were designed to measure both speed and precision. Validity evidence was assessed by correlating performance with self-reported endoscopic experience (surgeons and gastroenterologists [GIs]). Internal consistency of each test task was assessed using Cronbach's alpha. Test-retest reliability was determined by having the same participant perform the test a second time and comparing their scores. Passing scores were determined by a contrasting groups methodology and use of receiver operating characteristic curves. A total of 160 participants (17 % GIs) performed the simulator test. Scores on the five tasks showed good internal consistency reliability and all had significant correlations with endoscopic experience. Total FES scores correlated 0.73, with participants' level of endoscopic experience providing evidence of their validity, and their internal consistency reliability (Cronbach's alpha) was 0.82. Test-retest reliability was assessed in 11 participants, and the intraclass correlation was 0.85. The passing score was determined and is estimated to have a sensitivity (true positive rate) of 0.81 and a 1-specificity (false positive rate) of 0.21. The FES hands-on skills test examines the basic procedural components required to perform safe flexible endoscopy. It meets rigorous standards of reliability and validity required for high-stakes examinations, and, together with the knowledge component, may help contribute to the definition and determination of competence in endoscopy.
Arterial link travel time estimation using loop detector data : phase 1
DOT National Transportation Integrated Search
1997-11-01
The envisioned operational tests of Advanced Traveler Information Systems (ATIS) and Advanced Traffic Management Systems (ATMS) in the Minneapolis/St. Paul area call for the provision of timely and reliable travel times over an entire rod network. Un...
MSFC Skylab Orbital Workshop, volume 5
NASA Technical Reports Server (NTRS)
1974-01-01
The various programs involved in the development of the Skylab Orbital Workshop are discussed. The subjects considered include the following: (1) reliability program, (2) system safety program, (3) testing program, (4) engineering program management, (5) mission operations support, and (6) aerospace applications.
NASA Astrophysics Data System (ADS)
Berthet, Lionel; Marty, Renaud; Bourgin, François; Viatgé, Julie; Piotte, Olivier; Perrin, Charles
2017-04-01
An increasing number of operational flood forecasting centres assess the predictive uncertainty associated with their forecasts and communicate it to the end users. This information can match the end-users needs (i.e. prove to be useful for an efficient crisis management) only if it is reliable: reliability is therefore a key quality for operational flood forecasts. In 2015, the French flood forecasting national and regional services (Vigicrues network; www.vigicrues.gouv.fr) implemented a framework to compute quantitative discharge and water level forecasts and to assess the predictive uncertainty. Among the possible technical options to achieve this goal, a statistical analysis of past forecasting errors of deterministic models has been selected (QUOIQUE method, Bourgin, 2014). It is a data-based and non-parametric approach based on as few assumptions as possible about the forecasting error mathematical structure. In particular, a very simple assumption is made regarding the predictive uncertainty distributions for large events outside the range of the calibration data: the multiplicative error distribution is assumed to be constant, whatever the magnitude of the flood. Indeed, the predictive distributions may not be reliable in extrapolation. However, estimating the predictive uncertainty for these rare events is crucial when major floods are of concern. In order to improve the forecasts reliability for major floods, an attempt at combining the operational strength of the empirical statistical analysis and a simple error modelling is done. Since the heteroscedasticity of forecast errors can considerably weaken the predictive reliability for large floods, this error modelling is based on the log-sinh transformation which proved to reduce significantly the heteroscedasticity of the transformed error in a simulation context, even for flood peaks (Wang et al., 2012). Exploratory tests on some operational forecasts issued during the recent floods experienced in France (major spring floods in June 2016 on the Loire river tributaries and flash floods in fall 2016) will be shown and discussed. References Bourgin, F. (2014). How to assess the predictive uncertainty in hydrological modelling? An exploratory work on a large sample of watersheds, AgroParisTech Wang, Q. J., Shrestha, D. L., Robertson, D. E. and Pokhrel, P (2012). A log-sinh transformation for data normalization and variance stabilization. Water Resources Research, , W05514, doi:10.1029/2011WR010973
Reliability and validity of the new Tanaka B Intelligence Scale scores: a group intelligence test.
Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio
2014-01-01
The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2 ± 0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach's alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQ<70) was performed. In addition, stratum-specific likelihood ratios for detection of intellectual disability were calculated. The Cronbach's alpha for the new Tanaka B Intelligence Scale IQ (BIQ) was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85-0.96). In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9-48.9), and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03-0.4). Thus, intellectual disability could be ruled out or determined. The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult.
Reliability and Validity of the New Tanaka B Intelligence Scale Scores: A Group Intelligence Test
Uno, Yota; Mizukami, Hitomi; Ando, Masahiko; Yukihiro, Ryoji; Iwasaki, Yoko; Ozaki, Norio
2014-01-01
Objective The present study evaluated the reliability and concurrent validity of the new Tanaka B Intelligence Scale, which is an intelligence test that can be administered on groups within a short period of time. Methods The new Tanaka B Intelligence Scale and Wechsler Intelligence Scale for Children-Third Edition were administered to 81 subjects (mean age ± SD 15.2±0.7 years) residing in a juvenile detention home; reliability was assessed using Cronbach’s alpha coefficient, and concurrent validity was assessed using the one-way analysis of variance intraclass correlation coefficient. Moreover, receiver operating characteristic analysis for screening for individuals who have a deficit in intellectual function (an FIQ<70) was performed. In addition, stratum-specific likelihood ratios for detection of intellectual disability were calculated. Results The Cronbach’s alpha for the new Tanaka B Intelligence Scale IQ (BIQ) was 0.86, and the intraclass correlation coefficient with FIQ was 0.83. Receiver operating characteristic analysis demonstrated an area under the curve of 0.89 (95% CI: 0.85–0.96). In addition, the stratum-specific likelihood ratio for the BIQ≤65 stratum was 13.8 (95% CI: 3.9–48.9), and the stratum-specific likelihood ratio for the BIQ≥76 stratum was 0.1 (95% CI: 0.03–0.4). Thus, intellectual disability could be ruled out or determined. Conclusion The present results demonstrated that the new Tanaka B Intelligence Scale score had high reliability and concurrent validity with the Wechsler Intelligence Scale for Children-Third Edition score. Moreover, the post-test probability for the BIQ could be calculated when screening for individuals who have a deficit in intellectual function. The new Tanaka B Intelligence Test is convenient and can be administered within a variety of settings. This enables evaluation of intellectual development even in settings where performing intelligence tests have previously been difficult. PMID:24940880
Beemster, Timo T; van Velzen, Judith M; van Bennekom, Coen A M; Reneman, Michiel F; Frings-Dresen, Monique H W
2018-03-16
The purpose of this study was to assess test-retest reliability, agreement, and responsiveness of questionnaires on productivity loss (iPCQ-VR) and healthcare utilization (TiCP-VR) for sick-listed workers with chronic musculoskeletal pain who were referred to vocational rehabilitation. Methods Test-retest reliability and agreement was assessed with a 2-week interval. Responsiveness was assessed at discharge after a 15-week vocational rehabilitation (VR) program. Data was obtained from six Dutch VR centers. Test-retest reliability was determined with intraclass correlation coefficient (ICC) and Cohen's kappa. Agreement was determined by Standard Error of Measurement (SEM), smallest detectable changes (on group and individual level), and percentage observed, positive and negative agreement. Responsiveness was determined with area under the curve (AUC) obtained from receiver operation characteristic (ROC). Results A sample of 52 participants on test-retest reliability and agreement, and a sample of 223 on responsiveness were included in the analysis. Productivity loss (iPCQ-VR): ICCs ranged from 0.52 to 0.90, kappa ranged from 0.42 to 0.96, and AUC ranged from 0.55 to 0.86. Healthcare utilization (TiCP-VR): ICC was 0.81, and kappa values of the single healthcare utilization items ranged from 0.11 to 1.00. Conclusions The iPCQ-VR showed good measurement properties on working status, number of hours working per week and long-term sick leave, and low measurement properties on short-term sick leave and presenteeism. The TiCP-VR showed adequate reliability on all healthcare utilization items together and medication use, but showed low measurement properties on the single healthcare utilization items.
Huang, X N; Zhang, Y; Feng, W W; Wang, H S; Cao, B; Zhang, B; Yang, Y F; Wang, H M; Zheng, Y; Jin, X M; Jia, M X; Zou, X B; Zhao, C X; Robert, J; Jing, Jin
2017-06-02
Objective: To evaluate the reliability and validity of warning signs checklist developed by the National Health and Family Planning Commission of the People's Republic of China (NHFPC), so as to determine the screening effectiveness of warning signs on developmental problems of early childhood. Method: Stratified random sampling method was used to assess the reliability and validity of checklist of warning sign and 2 110 children 0 to 6 years of age(1 513 low-risk subjects and 597 high-risk subjects) were recruited from 11 provinces of China. The reliability evaluation for the warning signs included the test-retest reliability and interrater reliability. With the use of Age and Stage Questionnaire (ASQ) and Gesell Development Diagnosis Scale (GESELL) as the criterion scales, criterion validity was assessed by determining the correlation and consistency between the screening results of warning signs and the criterion scales. Result: In terms of the warning signs, the screening positive rates at different ages ranged from 10.8%(21/141) to 26.2%(51/137). The median (interquartile) testing time for each subject was 1(0.6) minute. Both the test-retest reliability and interrater reliability of warning signs reached 0.7 or above, indicating that the stability was good. In terms of validity assessment, there was remarkable consistency between ASQ and warning signs, with the Kappa value of 0.63. With the use of GESELL as criterion, it was determined that the sensitivity of warning signs in children with suspected developmental delay was 82.2%, and the specificity was 77.7%. The overall Youden index was 0.6. Conclusion: The reliability and validity of warning signs checklist for screening early childhood developmental problems have met the basic requirements of psychological screening scales, with the characteristics of short testing time and easy operation. Thus, this warning signs checklist can be used for screening psychological and behavioral problems of early childhood, especially in community settings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-01-01
Major accomplishments during the second quarter of 1984 were completion of the Diaphragm Separation Seal clear liquid testing, and initiation of Phase III Field Testing. Diaphragm operational testing was conducted on a clear water test loop. The test goals were to ensure; mechanical reliability of the Diaphragm Seal, safe operation with simulated component failure, and proper operation of the Diaphragm Buffer Volume Control System. This latter system is essential in controlling the phasing of the diaphragm with its driving plunger. These tests were completed successfully. All operational problems were solved. However, it must be emphasized that the Diaphragm Seal wouldmore » be damaged by allowing the pump to operate in a cavitating condition for an extended period of time. A change in the Field Test phase of the program was made regarding choice of field test site. There is no operating Syn-Fuel pilot plant capable of inexpensively producing the slurry stream required for the reciprocating pump testing. The Field Tests will now be conducted by first testing the prototype pump and separation seals in an ambient temperature sand water slurry. This will determine resistence to abrasive wear and determine any operation problems at pressure over a lengthy period of time. After successful conclusion of these tests the pump and seals will be operated with a high temperature oil, but without solids, to identify any problems associated with thermal gradients, thermal shock and differential growth. After successful completion of the high temperature clean oil tests the pump will be deemed ready for in-line installation at a designated Syn-Fuel pilot plant. The above approach avoids the expense and complications of a separate hot slurry test loop. It also reduces risk of operational problems while in-line at the pilot plant. 5 figs.« less
Field reliability of Ricor microcoolers
NASA Astrophysics Data System (ADS)
Pundak, N.; Porat, Z.; Barak, M.; Zur, Y.; Pasternak, G.
2009-05-01
Over the recent 25 years Ricor has fielded in excess of 50,000 Stirling cryocoolers, among which approximately 30,000 units are of micro integral rotary driven type. The statistical population of the fielded units is counted in thousands/ hundreds per application category. In contrast to MTTF values as gathered and presented based on standard reliability demonstration tests, where the failure of the weakest component dictates the end of product life, in the case of field reliability, where design and workmanship failures are counted and considered, the values are usually reported in number of failures per million hours of operation. These values are important and relevant to the prediction of service capabilities and plan.
Performance analysis and an assessment of operational issues of Ya-21U
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paramonov, D.V.; El-Genk, M.S.
1996-03-01
Extensive testing of the Soviet made TOPAZ-II space nuclear power system unit designated {open_quote}{open_quote}Ya-21U{close_quote}{close_quote} was conducted both in the USSR (1989{endash}1990) and in the US (August 1993 to March 1995). The unit underwent a total of 15 tests for a cumulative test/operation time of almost 8000 hours. These tests included steady-state operation at different power levels, fast startups and power optimizations. Leaks were detected in some of the Thermionic Fuel Elements (TFEs) after the first test in the US. These leaks that facilitated air incursion into the interelectrode gap caused operational changes in both electric power and conversion efficiency andmore » changed the optimum cesium pressure and load voltage. Additional changes in operational performance were detected following shock and vibration tests performed in August 1994. Test data was examined and analyzed to assess the performance of not only individual TFEs, and also the whole Ya-21U unit, and identify causes for measured operational performance changes; most probable causes were identified and discussed. The Ya-21U unit remained operational throughout extensive testing for 8000 hours at conditions far exceeding the design limits of the TOPAZ-II system. No single TFE was damaged during testing and measured operational performance changes were uniform among working section TFEs. In addition to providing a unique knowledge base for future development and operation of thermionic power systems, the test results testify to the reliability and ruggedness of the TOPAZ-II system design. {copyright} {ital 1996 American Institute of Physics.}« less
The state of the art of the development of SMES for bridging instantaneous voltage dips in Japan
NASA Astrophysics Data System (ADS)
Nagaya, Shigeo; Hirano, Naoki; Katagiri, Toshio; Tamada, Tsutomu; Shikimachi, Koji; Iwatani, Yu; Saito, Fusao; Ishii, Yusuke
2012-12-01
Development of apparatuses for protecting industrial facilities such as semiconductor plants or information industries from instantaneous voltage dips, which requires very large output power, has been expected. A Superconducting magnetic energy storage system (SMES), one of such apparatus, consists of superconducting magnets that must withstand high voltage during operation and require high reliability. We have already development of SMES using conventional superconducting coils and done the field test of the SMES for bridging instantaneous voltage dips. After field test, the commercial SMES for instantaneous voltage dips is working there. Since field test has started, we have confirmed nearly 40 operations, and all have succeeded. In 2011, three commercial SMES units for bridging instantaneous voltage dips are operating in Japan.
A flight test of laminar flow control leading-edge systems
NASA Technical Reports Server (NTRS)
Fischer, M. C.; Wright, A. S., Jr.; Wagner, R. D.
1983-01-01
NASA's program for development of a laminar flow technology base for application to commercial transports has made significant progress since its inception in 1976. Current efforts are focused on development of practical reliable systems for the leading-edge region where the most difficult problems in applying laminar flow exist. Practical solutions to these problems will remove many concerns about the ultimate practicality of laminar flow. To address these issues, two contractors performed studies, conducted development tests, and designed and fabricated fully functional leading-edge test articles for installation on the NASA JetStar aircraft. Systems evaluation and performance testing will be conducted to thoroughly evaluate all system capabilities and characteristics. A simulated airline service flight test program will be performed to obtain the operational sensitivity, maintenance, and reliability data needed to establish that practical solutions exist for the difficult leading-edge area of a future commercial transport employing laminar flow control.
Development of Reliable Life Support Systems
NASA Technical Reports Server (NTRS)
Carter, Layne
2017-01-01
The life support systems on the International Space Station (ISS) are the culmination of an extensive effort encompassing development, design, and test to provide the highest possible confidence in their operation on ISS. Many years of development testing are initially performed to identify the optimum technology and the optimum operational approach. The success of this development program depends on the accuracy of the system interfaces. The critical interfaces include the specific operational environment, the composition of the waste stream to be processed and the quality of the product. Once the development program is complete, a detailed system schematic is built based on the specific design requirements, followed by component procurement, assembly, and acceptance testing. A successful acceptance test again depends on accurately simulating the anticipated environment on ISS. The ISS Water Recovery System (WRS) provides an excellent example of where this process worked, as well as lessons learned that can be applied to the success of future missions. More importantly, ISS has provided a test bed to identify these design issues. Mechanical design issues have included an unreliable harmonic drive train in the Urine Processor's fluids pump, and seals in the Water Processor's Catalytic Reactor with insufficient life at the operational temperature. Systems issues have included elevated calcium in crew urine (due to microgravity effect) that resulted in precipitation at the desired water recovery rate, and the presence of an organosilicon compound (dimethylsilanediol) in the condensate that is not well removed by the water treatment process. Modifications to the WRS to address these issues are either complete (and now being evaluated on ISS) or are currently in work to insure the WRS has the required reliability before embarking on a mission to Mars.
Scientific Inquiry: A Model for Online Searching.
ERIC Educational Resources Information Center
Harter, Stephen P.
1984-01-01
Explores scientific inquiry as philosophical and behavioral model for online search specialist and information retrieval process. Nature of scientific research is described and online analogs to research concepts of variable, hypothesis formulation and testing, operational definition, validity, reliability, assumption, and cyclical nature of…
Bajaj, Jasmohan S; Heuman, Douglas M; Sterling, Richard K; Sanyal, Arun J; Siddiqui, Muhammad; Matherly, Scott; Luketic, Velimir; Stravitz, R Todd; Fuchs, Michael; Thacker, Leroy R; Gilles, HoChong; White, Melanie B; Unser, Ariel; Hovermale, James; Gavis, Edith; Noble, Nicole A; Wade, James B
2015-10-01
Detection of covert hepatic encephalopathy (CHE) is difficult, but point-of-care testing could increase rates of diagnosis. We aimed to validate the ability of the smartphone app EncephalApp, a streamlined version of Stroop App, to detect CHE. We evaluated face validity, test-retest reliability, and external validity. Patients with cirrhosis (n = 167; 38% with overt HE [OHE]; mean age, 55 years; mean Model for End-Stage Liver Disease score, 12) and controls (n = 114) were each given a paper and pencil cognitive battery (standard) along with EncephalApp. EncephalApp has Off and On states; results measured were OffTime, OnTime, OffTime+OnTime, and number of runs required to complete 5 off and on runs. Thirty-six patients with cirrhosis underwent driving simulation tests, and EncephalApp results were correlated with results. Test-retest reliability was analyzed in a subgroup of patients. The test was performed before and after transjugular intrahepatic portosystemic shunt placement, and before and after correction for hyponatremia, to determine external validity. All patients with cirrhosis performed worse on paper and pencil and EncephalApp tests than controls. Patients with cirrhosis and OHE performed worse than those without OHE. Age-dependent EncephalApp cutoffs (younger or older than 45 years) were set. An OffTime+OnTime value of >190 seconds identified all patients with CHE with an area under the receiver operator characteristic value of 0.91; the area under the receiver operator characteristic value was 0.88 for diagnosis of CHE in those without OHE. EncephalApp times correlated with crashes and illegal turns in driving simulation tests. Test-retest reliability was high (intraclass coefficient, 0.83) among 30 patients retested 1-3 months apart. OffTime+OnTime increased significantly (206 vs 255 seconds, P = .007) among 10 patients retested 33 ± 7 days after transjugular intrahepatic portosystemic shunt placement. OffTime+OnTime decreased significantly (242 vs 225 seconds, P = .03) in 7 patients tested before and after correction for hyponatremia (126 ± 3 to 132 ± 4 meq/L, P = .01) 10 ± 5 days apart. A smartphone app called EncephalApp has good face validity, test-retest reliability, and external validity for the diagnosis of CHE. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.
An investigation during the system test phase of the GOES spacecraft
NASA Technical Reports Server (NTRS)
Mallette, L. A.
1983-01-01
Spurious RF oscillations were noted during the system test phase of the Geostationary Operational Environmental Satellite (GOES). A space qualified data collection platform report (DCPR) transmitter was subsequently found to have a cracked load resistor in its output isolator. The failure mechanism was caused by heat from the output power of a 20 watt transmitter being reflected into the DCPR transmitter through a sneak path. The reflection from a high VSWR at the rotary joint was not part of the normal operation but was due to unusual circumstances. The reliability of the load resistor under normal operation (low VSWR) over the life of the satellite was determined to be high.
NASA Astrophysics Data System (ADS)
Shi, Yu-Fang; Ma, Yi-Yi; Song, Ping-Ping
2018-03-01
System Reliability Theory is a research hotspot of management science and system engineering in recent years, and construction reliability is useful for quantitative evaluation of project management level. According to reliability theory and target system of engineering project management, the defination of construction reliability appears. Based on fuzzy mathematics theory and language operator, value space of construction reliability is divided into seven fuzzy subsets and correspondingly, seven membership function and fuzzy evaluation intervals are got with the operation of language operator, which provides the basis of corresponding method and parameter for the evaluation of construction reliability. This method is proved to be scientific and reasonable for construction condition and an useful attempt for theory and method research of engineering project system reliability.
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Rothmann, Elizabeth; Mittal, Nitin; Koppen, Sandra Howell
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems, and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical preprocessor Graphics Oriented (GO) program. GO is a graphical user interface for the HARP engine that enables the drawing of reliability/availability models on a monitor. A mouse is used to select fault tree gates or Markov graphical symbols from a menu for drawing.
Pigini, Lucia; Bovi, Gabriele; Panzarino, Claudia; Gower, Valerio; Ferratini, Maurizio; Andreoni, Giuseppe; Sassi, Roberto; Rivolta, Massimo W; Ferrarin, Maurizio
2017-01-01
The increase in life expectancy is accompanied by a growing number of elderly subjects affected by chronic comorbidities, a health issue which also implies important socioeconomic consequences. Shifting from hospital or community dwelling care towards a home personalized healthcare paradigm would promote active aging with a better quality of life, along with a reduction in healthcare-related costs. The aim of the SMARTA project was to develop and test an innovative personal health system integrating standard sensors as well as innovative wearable and environmental sensors to allow home telemonitoring of vital parameters and detection of anomalies in daily activities, thus supporting active aging through remote healthcare. A first phase of the project consisted in the definition of the health and environmental parameters to be monitored (electrocardiography and actigraphy, blood pressure and oxygen saturation, weight, ear temperature, glycemia, home interaction monitoring - water tap, refrigerator, and dishwasher), the feedbacks for the clinicians, and the reminders for the patients. It was followed by a technical feasibility analysis leading to an iterative process of prototype development, sensor integration, and testing. Once the prototype had reached an advanced stage of development, a group of 32 volunteers - including 15 healthy adult subjects, 13 elderly people with cardiac diseases, and 4 clinical operators - was recruited to test the system in a real home setting, in order to evaluate both technical reliability and user perception of the system in terms of effectiveness, usability, acceptance, and attractiveness. The testing in a real home setting showed a good perception of the SMARTA system and its functionalities both by the patients and by the clinicians, who appreciated the user interface and the clinical governance system. The moderate system reliability of 65-70% evidenced some technical issues, mainly related to sensor integration, while the patient's user interface showed excellent reliability (100%). Both elderly people and clinical operators considered the SMARTA system a promising and attractive tool for improving patients' healthcare while reducing related costs and preserving quality of life. However, the moderate reliability of the system should prompt further technical developments in terms of sensor integration and usability of the clinical operator's user interface. © 2017 S. Karger AG, Basel.
[Experimental studies of micromotor headpieces].
Kanaev, V F; Repin, V A
1982-01-01
Experimental studies of handpieces for micromotors have been performed to make more precise their operating parameters. The special stand has been used for the measurements of the following data: head temperature, power losses in handpieces at no-load, and operating power required for machining by means of spherical burrs. The experimental results made it possible to specify more exactly the range of handpiece rotational speeds and to select optimum loads under reliability testing.
Director, Operational Test and Evaluation FY 2004 Annual Report
2004-01-01
HIGH) Space Based Radar (SBR) Sensor Fuzed Weapon (SFW) P3I (CBU-97/B) Small Diameter Bomb (SDB) Secure Mobile Anti-Jam Reliable Tactical Terminal...detection, identification, and sampling capability for both fixed-site and mobile operations. The system must automatically detect and identify up to ten...staffing within the Services. SYSTEM DESCRIPTION AND MISSION The Services envision JCAD as a hand-held device that automatically detects, identifies, and
Reusability aspects for space transportation rocket engines: programmatic status and outlook
NASA Astrophysics Data System (ADS)
Preclik, D.; Strunz, R.; Hagemann, G.; Langel, G.
2011-09-01
Rocket propulsion systems belong to the most critical subsystems of a space launch vehicle, being illustrated in this paper by comparing different types of transportation systems. The aspect of reusability is firstly discussed for the space shuttle main engine, the only rocket engine in the world that has demonstrated multiple reuses. Initial projections are contrasted against final reusability achievements summarizing three decades of operating the space shuttle main engine. The discussion is then extended to engines employed on expendable launch vehicles with an operational life requirement typically specifying structural integrities up to 20 cycles (start-ups) and an accumulated burning time of about 6,000 s (Vulcain engine family). Today, this life potential substantially exceeds the duty cycle of an expendable engine. It is actually exploited only during the development and qualification phase of an engine when system reliability is demonstrated on ground test facilities with a reduced number of hardware sets that are subjected to an extended number of test cycles and operation time. The paper will finally evaluate the logic and effort necessary to qualify a reusable engine for a required reliability and put this result in context of possible cost savings realized from reuse operations over a time span of 25 years.
One tool - one team: the marriage of test and operations in a low-budget spacecraft development
NASA Astrophysics Data System (ADS)
Finley, Charles J.
2006-05-01
The Air Force Research Laboratory's Space Vehicles Directorate (AFRL/VS) and the Department of Defense Space Test Program (STP) are two organizations that have partnered on more than 85 missions since 1968 to develop, launch, and operate Research and Development, Test and Evaluation space missions. As valuable as these missions have been to the follow-on generation of Operational systems, they are consistently under-funded and forced to execute on excessively ambitious development schedules. Due to these constraints, space mission development teams that serve the RDT&E community are faced with a number of unique technical and programmatic challenges. AFRL and STP have taken various approaches throughout the mission lifecycle to accelerate their development schedules, without sacrificing cost or system reliability. In the areas of test and operations, they currently employ one of two strategies. Historically, they have sought to avoid the added cost and complexity associated with coupled development schedules and segregated the spacecraft development and test effort from the ground operations system development and test effort. However, because these efforts have far more in common than they have differences, they have more recently attempted to pursue parallel I&T and Operations development and readiness efforts. This paper seeks to compare and contrast the "decoupled test and operations" approach, used by such missions as C/NOFS and Coriolis, with the "coupled test and operations" approach, adopted by the XSS-11 and TacSat-2 missions.
NASA Astrophysics Data System (ADS)
Hodges, Aaron; Wang, Jun; DeFranza, Mark; Liu, Xingsheng; Vivian, Bill; Johnson, Curt; Crump, Paul; Leisher, Paul; DeVito, Mark; Martinsen, Robert; Bell, Jacob
2007-04-01
A conductively cooled laser diode package design with hard AuSn solder and CTE matched sub mount is presented. We discuss how this platform eliminates the failure mechanisms associated with indium solder. We present the problem of catastrophic optical mirror damage (COMD) and show that nLight's nXLT TM facet passivation technology effectively eliminates facet defect initiated COMD as a failure mechanism for both single emitter and bar format laser diodes. By combining these technologies we have developed a product that has high reliability at high powers, even at increased operation temperatures. We present early results from on-going accelerated life testing of this configuration that suggests an 808nm, 30% fill factor device will have a MTTF of more than 21khrs at 60W CW, 25°C operating conditions and a MTTF of more than 6.4khrs when operated under hard pulsed (1 second on, 1 second off) conditions.
An automated environment for multiple spacecraft engineering subsystem mission operations
NASA Technical Reports Server (NTRS)
Bahrami, K. A.; Hioe, K.; Lai, J.; Imlay, E.; Schwuttke, U.; Hsu, E.; Mikes, S.
1990-01-01
Flight operations at the Jet Propulsion Laboratory (JPL) are now performed by teams of specialists, each team dedicated to a particular spacecraft. Certain members of each team are responsible for monitoring the performances of their respective spacecraft subsystems. Ground operations, which are very complex, are manual, labor-intensive, slow, and tedious, and therefore costly and inefficient. The challenge of the new decade is to operate a large number of spacecraft simultaneously while sharing limited human and computer resources, without compromising overall reliability. The Engineering Analysis Subsystem Environment (EASE) is an architecture that enables fewer controllers to monitor and control spacecraft engineering subsystems. A prototype of EASE has been installed in the JPL Space Flight Operations Facility for on-line testing. This article describes the underlying concept, development, testing, and benefits of the EASE prototype.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-26
... Operations, Inc., Including On-Site Leased Workers From Reliable Temp Services, Inc., Johnson & Hill Staffing... Golf Ball Operations, Inc., including on-site leased workers from Reliable Temp Services, Inc., and... Reliable Temp Services, Inc., Johnson & Hill Staffing and Apollo Security, Chicopee, Massachusetts, who...
Development of a non-explosive release actuator using shape memory alloy wire.
Yoo, Young Ik; Jeong, Ju Won; Lim, Jae Hyuk; Kim, Kyung-Won; Hwang, Do-Soon; Lee, Jung Ju
2013-01-01
We have developed a newly designed non-explosive release actuator that can replace currently used release devices. The release mechanism is based on a separation mechanism, which relies on segmented nuts and a shape memory alloy (SMA) wire trigger. A quite fast and simple trigger operation is made possible through the use of SMA wire. This actuator is designed to allow a high preload with low levels of shock for the solar arrays of medium-size satellites. After actuation, the proposed device can be easily and instantly reset. Neither replacement, nor refurbishment of any components is necessary. According to the results of a performance test, the release time, preload capacity, and maximum shock level are 50 ms, 15 kN, and 350 G, respectively. In order to increase the reliability of the actuator, more than ten sets of performance tests are conducted. In addition, the proposed release actuator is tested under thermal vacuum and extreme vibration environments. No degradation or damage was observed during the two environment tests, and the release actuator was able to operate successfully. Considering the test results as a whole, we conclude that the proposed non-explosive release actuator can be applied reliably to intermediate-size satellites to replace existing release systems.
Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erin V.
2007-01-01
A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for a 2-bearing shaft assembly in each body flap actuator established a reliability level of 99.6 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.
Probabilistic Analysis of Space Shuttle Body Flap Actuator Ball Bearings
NASA Technical Reports Server (NTRS)
Oswald, Fred B.; Jett, Timothy R.; Predmore, Roamer E.; Zaretsky, Erwin V.
2008-01-01
A probabilistic analysis, using the 2-parameter Weibull-Johnson method, was performed on experimental life test data from space shuttle actuator bearings. Experiments were performed on a test rig under simulated conditions to determine the life and failure mechanism of the grease lubricated bearings that support the input shaft of the space shuttle body flap actuators. The failure mechanism was wear that can cause loss of bearing preload. These tests established life and reliability data for both shuttle flight and ground operation. Test data were used to estimate the failure rate and reliability as a function of the number of shuttle missions flown. The Weibull analysis of the test data for the four actuators on one shuttle, each with a 2-bearing shaft assembly, established a reliability level of 96.9 percent for a life of 12 missions. A probabilistic system analysis for four shuttles, each of which has four actuators, predicts a single bearing failure in one actuator of one shuttle after 22 missions (a total of 88 missions for a 4-shuttle fleet). This prediction is comparable with actual shuttle flight history in which a single actuator bearing was found to have failed by wear at 20 missions.
NASA Technical Reports Server (NTRS)
Holden, D. G.
1975-01-01
Hard Over Monitoring Equipment (HOME) has been designed to complement and enhance the flight safety of a flight research helicopter. HOME is an independent, highly reliable, and fail-safe special purpose computer that monitors the flight control commands issued by the flight control computer of the helicopter. In particular, HOME detects the issuance of a hazardous hard-over command for any of the four flight control axes and transfers the control of the helicopter to the flight safety pilot. The design of HOME incorporates certain reliability and fail-safe enhancement design features, such as triple modular redundancy, majority logic voting, fail-safe dual circuits, independent status monitors, in-flight self-test, and a built-in preflight exerciser. The HOME design and operation is described with special emphasis on the reliability and fail-safe aspects of the design.
Temperature Control with Two Parallel Small Loop Heat Pipes for GLM Program
NASA Technical Reports Server (NTRS)
Khrustalev, Dmitry; Stouffer, Chuck; Ku, Jentung; Hamilton, Jon; Anderson, Mark
2014-01-01
The concept of temperature control of an electronic component using a single Loop Heat Pipe (LHP) is well established for Aerospace applications. Using two LHPs is often desirable for redundancy/reliability reasons or for increasing the overall heat source-sink thermal conductance. This effort elaborates on temperature controlling operation of a thermal system that includes two small ammonia LHPs thermally coupled together at the evaporator end as well as at the condenser end and operating "in parallel". A transient model of the LHP system was developed on the Thermal Desktop (TradeMark) platform to understand some fundamental details of such parallel operation of the two LHPs. Extensive thermal-vacuum testing was conducted with two thermally coupled LHPs operating simultaneously as well as with only one LHP operating at a time. This paper outlines the temperature control procedures for two LHPs operating simultaneously with widely varying sink temperatures. The test data obtained during the thermal-vacuum testing, with both LHPs running simultaneously in comparison with only one LHP operating at a time, are presented with detailed explanations.
Catalytic ignition of hydrogen/oxygen
NASA Technical Reports Server (NTRS)
Green, James M.; Zurawski, Robert L.
1988-01-01
An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen. Shell 405 granular catalyst and a unique monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant inlet temperature, and back pressure were varied parametrically in testing to determine the operational limits of a catalytic igniter. The test results showed that the gaseous hydrogen/oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. The results of the experimental program and the established operational limits for a catalytic igniter using both the granular and monolithic catalysts are presented. The capabilities of a facility constructed to conduct the igniter testing and the advantages of a catalytic igniter over other ignition systems for gaseous hydrogen and oxygen are also discussed.
NASA Technical Reports Server (NTRS)
Norcross, Jason; Jarvis, Sarah; Bekdash, Omar; Cupples, Scott; Abercromby, Andrew
2017-01-01
The primary objective of this study is to develop a protocol to reliably characterize human health and performance metrics for individuals working inside various EVA suits under realistic spaceflight conditions. Expected results and methodologies developed during this study will provide the baseline benchmarking data and protocols with which future EVA suits and suit configurations (e.g., varied pressure, mass, center of gravity [CG]) and different test subject populations (e.g., deconditioned crewmembers) may be reliably assessed and compared. Results may also be used, in conjunction with subsequent testing, to inform fitness-for-duty standards, as well as design requirements and operations concepts for future EVA suits and other exploration systems.
Power Hardware-in-the-Loop (PHIL) Testing Facility for Distributed Energy Storage (Poster)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neubauer.J.; Lundstrom, B.; Simpson, M.
2014-06-01
The growing deployment of distributed, variable generation and evolving end-user load profiles presents a unique set of challenges to grid operators responsible for providing reliable and high quality electrical service. Mass deployment of distributed energy storage systems (DESS) has the potential to solve many of the associated integration issues while offering reliability and energy security benefits other solutions cannot. However, tools to develop, optimize, and validate DESS control strategies and hardware are in short supply. To fill this gap, NREL has constructed a power hardware-in-the-loop (PHIL) test facility that connects DESS, grid simulator, and load bank hardware to a distributionmore » feeder simulation.« less
Preliminary test of the prototype modular cryostat for a 10 MW offshore superconducting wind turbine
NASA Astrophysics Data System (ADS)
Sun, Jiuce; Ramalingam, R.; Sanz, Santiago; Neumann, Holger
2017-02-01
The SUPerconducting Reliable lightweight And more POWERful offshore wind turbine (SUPRAPOWER), an EU FP7 funded research project, are under development for an innovative superconducting 10 MW class offshore wind turbine. Due to the requirements of handling, maintenance, reliability of long term and offshore operation, the cryostats are divided in two major parts: the modular cryostat able to accommodate a single coil and a thermal collector that links all the modules. The prototype modular cryostat was designed, manufactured and assembled in Karlsruhe Institute of Technology (KIT). The paper reports preliminary test results of proto-type modular cryostat with a two-stage Gifford-McMahon (GM) cryocooler.
Microgrids and distributed generation systems: Control, operation, coordination and planning
NASA Astrophysics Data System (ADS)
Che, Liang
Distributed Energy Resources (DERs) which include distributed generations (DGs), distributed energy storage systems, and adjustable loads are key components in microgrid operations. A microgrid is a small electric power system integrated with on-site DERs to serve all or some portion of the local load and connected to the utility grid through the point of common coupling (PCC). Microgrids can operate in both grid-connected mode and island mode. The structure and components of hierarchical control for a microgrid at Illinois Institute of Technology (IIT) are discussed and analyzed. Case studies would address the reliable and economic operation of IIT microgrid. The simulation results of IIT microgrid operation demonstrate that the hierarchical control and the coordination strategy of distributed energy resources (DERs) is an effective way of optimizing the economic operation and the reliability of microgrids. The benefits and challenges of DC microgrids are addressed with a DC model for the IIT microgrid. We presented the hierarchical control strategy including the primary, secondary, and tertiary controls for economic operation and the resilience of a DC microgrid. The simulation results verify that the proposed coordinated strategy is an effective way of ensuring the resilient response of DC microgrids to emergencies and optimizing their economic operation at steady state. The concept and prototype of a community microgrid that interconnecting multiple microgrids in a community are proposed. Two works are conducted. For the coordination, novel three-level hierarchical coordination strategy to coordinate the optimal power exchanges among neighboring microgrids is proposed. For the planning, a multi-microgrid interconnection planning framework using probabilistic minimal cut-set (MCS) based iterative methodology is proposed for enhancing the economic, resilience, and reliability signals in multi-microgrid operations. The implementation of high-reliability microgrids requires proper protection schemes that effectively function in both grid-connected and island modes. This chapter presents a communication-assisted four-level hierarchical protection strategy for high-reliability microgrids, and tests the proposed protection strategy based on a loop structured microgrid. The simulation results demonstrate the proposed strategy to be an effective and efficient option for microgrid protection. Additionally, microgrid topology ought to be optimally planned. To address the microgrid topology planning, a graph-partitioning and integer-programming integrated methodology is proposed. This work is not included in the dissertation. Interested readers can refer to our related publication.
Design of a Facility to Test the Advanced Stirling Radioisotope Generator Engineering Unit
NASA Technical Reports Server (NTRS)
Lewandowski, Edward J.; Schreiber, Jeffrey G.; Oriti, Salvatore M.; Meer, David W.; Brace, Michael H.; Dugala, Gina
2009-01-01
The Advanced Stirling Radioisotope Generator (ASRG) is being considered to power deep space missions. An engineering unit, the ASRG-EU, was designed and fabricated by Lockheed Martin under contract to the Department of Energy. This unit is currently on an extended operation test at NASA Glenn Research Center to generate performance data and validate the life and reliability predictions for the generator and the Stirling convertors. A special test facility was designed and built for testing the ASRG-EU. Details of the test facility design are discussed. The facility can operate the convertors under AC bus control or with the ASRG-EU controller. It can regulate input thermal power in either a fixed temperature or fixed power mode. An enclosure circulates cooled air around the ASRG-EU to remove heat rejected from the ASRG-EU by convection. A custom monitoring and data acquisition system supports the test. Various safety features, which allow 2417 unattended operation, are discussed.
RELIABILITY TESTING OF AN ON-HARVESTER COTTON WEIGHT MEASUREMENT SYSTEM
USDA-ARS?s Scientific Manuscript database
A system for weighing seed cotton onboard stripper harvesters was developed and installed on several producer owned and operated machines. The weight measurement system provides critical information to producers when in the process of calibrating yield monitors or conducting on-farm research. The ...
DOT National Transportation Integrated Search
1998-08-01
The DIRECT project compared four low-cost driver information systems. Of the four that were : compared, the RDS approach proved superior to the others in toggling reliability and voice quality. The DIRECT project planned to expand the implementation ...
Towards Autonomous Inspection of Space Systems Using Mobile Robotic Sensor Platforms
NASA Technical Reports Server (NTRS)
Wong, Edmond; Saad, Ashraf; Litt, Jonathan S.
2007-01-01
The space transportation systems required to support NASA's Exploration Initiative will demand a high degree of reliability to ensure mission success. This reliability can be realized through autonomous fault/damage detection and repair capabilities. It is crucial that such capabilities are incorporated into these systems since it will be impractical to rely upon Extra-Vehicular Activity (EVA), visual inspection or tele-operation due to the costly, labor-intensive and time-consuming nature of these methods. One approach to achieving this capability is through the use of an autonomous inspection system comprised of miniature mobile sensor platforms that will cooperatively perform high confidence inspection of space vehicles and habitats. This paper will discuss the efforts to develop a small scale demonstration test-bed to investigate the feasibility of using autonomous mobile sensor platforms to perform inspection operations. Progress will be discussed in technology areas including: the hardware implementation and demonstration of robotic sensor platforms, the implementation of a hardware test-bed facility, and the investigation of collaborative control algorithms.
Nettleton, D; Muñiz, J
2001-09-01
In this article, we revise and try to resolve some of the problems inherent in questionnaire screening of sleep apnea cases and apnea diagnosis based on attributes which are relevant and reliable. We present a way of learning information about the relevance of the data, comparing this with the definition of the information by the medical expert. We generate a predictive data model using a data aggregation operator which takes relevance and reliability information about the data into account to produce a diagnosis for each case. We also introduce a grade of membership for each question response which allows the patient to indicate a level of confidence or doubt in their own judgement. The method is tested with data collected from patients in a Sleep Clinic using questionnaires specially designed for the study. Other artificial intelligence predictive modeling algorithms are also tested on the same data and their predictive accuracy compared to that of the aggregation operator.
Advanced Stirling Convertor Heater Head Durability and Reliability Quantification
NASA Technical Reports Server (NTRS)
Krause, David L.; Shah, Ashwin R.; Korovaichuk, Igor; Kalluri, Sreeramesh
2008-01-01
The National Aeronautics and Space Administration (NASA) has identified the high efficiency Advanced Stirling Radioisotope Generator (ASRG) as a candidate power source for long duration Science missions, such as lunar applications, Mars rovers, and deep space missions, that require reliable design lifetimes of up to 17 years. Resistance to creep deformation of the MarM-247 heater head (HH), a structurally critical component of the ASRG Advanced Stirling Convertor (ASC), under high temperatures (up to 850 C) is a key design driver for durability. Inherent uncertainties in the creep behavior of the thin-walled HH and the variations in the wall thickness, control temperature, and working gas pressure need to be accounted for in the life and reliability prediction. Due to the availability of very limited test data, assuring life and reliability of the HH is a challenging task. The NASA Glenn Research Center (GRC) has adopted an integrated approach combining available uniaxial MarM-247 material behavior testing, HH benchmark testing and advanced analysis in order to demonstrate the integrity, life and reliability of the HH under expected mission conditions. The proposed paper describes analytical aspects of the deterministic and probabilistic approaches and results. The deterministic approach involves development of the creep constitutive model for the MarM-247 (akin to the Oak Ridge National Laboratory master curve model used previously for Inconel 718 (Special Metals Corporation)) and nonlinear finite element analysis to predict the mean life. The probabilistic approach includes evaluation of the effect of design variable uncertainties in material creep behavior, geometry and operating conditions on life and reliability for the expected life. The sensitivity of the uncertainties in the design variables on the HH reliability is also quantified, and guidelines to improve reliability are discussed.
Kim, Hee-Ju; Abraham, Ivo
2017-01-01
Evidence is needed on the clinicometric properties of single-item or short measures as alternatives to comprehensive measures. We examined whether two single-item fatigue measures (i.e., Likert scale, numeric rating scale) or a short fatigue measure were comparable to a comprehensive measure in reliability (i.e., internal consistency and test-retest reliability) and validity (i.e., convergent, concurrent, and predictive validity) in Korean young adults. For this quantitative study, we selected the Functional Assessment of Chronic Illness Therapy-Fatigue for the comprehensive measure and the Profile of Mood States-Brief, Fatigue subscale for the short measure; and constructed two single-item measures. A total of 368 students from four nursing colleges in South Korea participated. We used Cronbach's alpha and item-total correlation for internal consistency reliability and intraclass correlation coefficient for test-retest reliability. We assessed Pearson's correlation with a comprehensive measure for convergent validity, with perceived stress level and sleep quality for concurrent validity and the receiver operating characteristic curve for predictive validity. The short measure was comparable to the comprehensive measure in internal consistency reliability (Cronbach's alpha=0.81 vs. 0.88); test-retest reliability (intraclass correlation coefficient=0.66 vs. 0.61); convergent validity (r with comprehensive measure=0.79); concurrent validity (r with perceived stress=0.55, r with sleep quality=0.39) and predictive validity (area under curve=0.88). Single-item measures were not comparable to the comprehensive measure. A short fatigue measure exhibited similar levels of reliability and validity to the comprehensive measure in Korean young adults. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA 30,000 hour test demonstration of closed Brayton cycle reliability
NASA Technical Reports Server (NTRS)
Mccormick, J. E.; Dunn, J. H.
1977-01-01
Four Brayton rotating units (BRU) developed by an American company were tested in connection with studies concerning the feasibility to use closed Brayton power conversion systems for space applications. The rotating assembly operates at a speed of 36,000 rpm and consists of a radial outflow compressor, a four-pole Rice alternator/motor, and a radial inflow turbine. The cycle working fluid consists of a mixture of helium and xenon. After 20,000 hours of operation, there was no apparent wear on failure mode to prevent attainment of the 5-year BRU design life objective.
NASA Technical Reports Server (NTRS)
1971-01-01
The reliability of semiconductor devices as influenced by the reliability of wire bonds used in the assembly of the devices is investigated. The specific type of failure dealt with involves fracture of wire bonds as a result of repeated flexure of the wire at the heel of the bond when the devices are operated in an on-off mode. The mechanism of failure is one of induced fracture of the wire. To improve the reliability of a chosen transistor, one-mil diameter wires of aluminum with various alloy additions were studied using an accelerated fatigue testing machine. In addition, the electroprobe was used to study the metallurgy of the wires as to microstructure and kinetics of the growth of insoluble phases. Thermocompression and ultrasonic bonding techniques were also investigated.
Comparison between the Laser-Badal and Vernier Optometers.
1988-09-01
naval aviators (SNAs). We also measured dark vcrgence in the same sample of SNAs. THE FINDINGS There was no statistically significant difference found...relatively inexperienced operator. 7. The difference between mean scores on the vernier and laser-Badal optometers was statistically significant...thus indicating that test results were reliable within instru- menrts. TAbLE 1. Test and Retest Statistics . Measure Mean SD n t-value Dark vergence
EBR-II high-ramp transients under computer control
DOE Office of Scientific and Technical Information (OSTI.GOV)
Forrester, R.J.; Larson, H.A.; Christensen, L.J.
1983-01-01
During reactor run 122, EBR-II was subjected to 13 computer-controlled overpower transients at ramps of 4 MWt/s to qualify the facility and fuel for transient testing of LMFBR oxide fuels as part of the EBR-II operational-reliability-testing (ORT) program. A computer-controlled automatic control-rod drive system (ACRDS), designed by EBR-II personnel, permitted automatic control on demand power during the transients.
2016-07-27
is a common requirement for aircraft, rockets , and hypersonic vehicles. The Aerospace Fuels Quality Test and Model Development (AFQTMoDev) project...was initiated to mature fuel quality assurance practices for rocket grade kerosene, thereby ensuring operational readiness of conventional and...and reliability, is a common requirement for aircraft, rockets , and hypersonic vehicles. The Aerospace Fuels Quality Test and Model Development
Highly-reliable laser diodes and modules for spaceborne applications
NASA Astrophysics Data System (ADS)
Deichsel, E.
2017-11-01
Laser applications become more and more interesting in contemporary missions such as earth observations or optical communication in space. One of these applications is light detection and ranging (LIDAR), which comprises huge scientific potential in future missions. The Nd:YAG solid-state laser of such a LIDAR system is optically pumped using 808nm emitting pump sources based on semiconductor laser-diodes in quasi-continuous wave (qcw) operation. Therefore reliable and efficient laser diodes with increased output powers are an important requirement for a spaceborne LIDAR-system. In the past, many tests were performed regarding the performance and life-time of such laser-diodes. There were also studies for spaceborne applications, but a test with long operation times at high powers and statistical relevance is pending. Other applications, such as science packages (e.g. Raman-spectroscopy) on planetary rovers require also reliable high-power light sources. Typically fiber-coupled laser diode modules are used for such applications. Besides high reliability and life-time, designs compatible to the harsh environmental conditions must be taken in account. Mechanical loads, such as shock or strong vibration are expected due to take-off or landing procedures. Many temperature cycles with high change rates and differences must be taken in account due to sun-shadow effects in planetary orbits. Cosmic radiation has strong impact on optical components and must also be taken in account. Last, a hermetic sealing must be considered, since vacuum can have disadvantageous effects on optoelectronics components.
High duty cycle hard soldered kilowatt laser diode arrays
NASA Astrophysics Data System (ADS)
Klumel, Genady; Karni, Yoram; Oppenheim, Jacob; Berk, Yuri; Shamay, Moshe; Tessler, Renana; Cohen, Shalom
2010-02-01
High-brightness laser diode arrays operating at a duty cycle of 10% - 20% are in ever-increasing demand for the optical pumping of solid state lasers and directed energy applications. Under high duty-cycle operation at 10% - 20%, passive (conductive) cooling is of limited use, while micro-coolers using de-ionized cooling water can considerably degrade device reliability. When designing and developing actively-cooled collimated laser diode arrays for high duty cycle operation, three main problems should be carefully addressed: an effective local and total heat removal, a minimization of packaging-induced and operational stresses, and high-precision fast axis collimation. In this paper, we present a novel laser diode array incorporating a built-in tap water cooling system, all-hard-solder bonded assembly, facet-passivated high-power 940 nm laser bars and tight fast axis collimation. By employing an appropriate layout of water cooling channels, careful choice of packaging materials, proper design of critical parts, and active optics alignment, we have demonstrated actively-cooled collimated laser diode arrays with extended lifetime and reliability, without compromising their efficiency, optical power density, brightness or compactness. Among the key performance benchmarks achieved are: 150 W/bar optical peak power at 10% duty cycle, >50% wallplug efficiency and <1° collimated fast axis divergence. A lifetime of >0.5 Ghots with <2% degradation has been experimentally proven. The laser diode arrays have also been successfully tested under harsh environmental conditions, including thermal cycling between -20°C and 40°C and mechanical shocks at 500g acceleration. The results of both performance and reliability testing bear out the effectiveness and robustness of the manufacturing technology for high duty-cycle laser arrays.
Space reliability technology - A historical perspective
NASA Technical Reports Server (NTRS)
Cohen, H.
1984-01-01
The progressive improvements in reliability of launch vehicles is traced from the Vanguard rocket to the STS. The Vanguard, built with minimal redundancy and a high mass ratio, was used as an operational vehicle midway through its test program in an attempt to meet the perceived challenge represented by the Sputnik. The fourth Vanguard failed due to inadequate contamination prevention and lack of inspection ports. Automatic firing sequences were adopted for the Titan rockets, which were an order of magnitude larger than the Vanguard and therefore had room for interior inspections. Qualification testing and reporting were introduced for components, along with X ray inspection of fuel tank welds. Dual systems were added for flight critical components when the Titan became man-rated for the Gemini program. Designs incorporated full failure mode effects and criticality analyses for the Apollo program, which exposed the limits of applicability of numerical reliability models. Fault tree analyses and program milestone reviews were initiated. The worth of man-in-the-loop in space activities for reliability was demonstrated with the rescue of Skylab after solar panel and meteoroid shield failures. It is now the reliability of the payload, rather than the vehicle, that is questioned for Shuttle launches.
Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (Orion)
NASA Technical Reports Server (NTRS)
DeMott, Diana L.; Bigler, Mark A.
2017-01-01
NASA (National Aeronautics and Space Administration) Johnson Space Center (JSC) Safety and Mission Assurance (S&MA) uses two human reliability analysis (HRA) methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate or screening value is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a Probabilistic Risk Assessment (PRA) that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more challenging. To determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators, and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the assumptions and expectations expressed in the assessments will be needed when the procedures, flight rules, and operational requirements are developed and then finalized.
Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (Orion)
NASA Technical Reports Server (NTRS)
DeMott, Diana; Bigler, Mark
2016-01-01
NASA (National Aeronautics and Space Administration) Johnson Space Center (JSC) Safety and Mission Assurance (S&MA) uses two human reliability analysis (HRA) methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate or screening value is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a Probabilistic Risk Assessment (PRA) that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more challenging. In order to determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the assumptions and expectations expressed in the assessments will be needed when the procedures, flight rules and operational requirements are developed and then finalized.
Deuterium results at the negative ion source test facility ELISE
NASA Astrophysics Data System (ADS)
Kraus, W.; Wünderlich, D.; Fantz, U.; Heinemann, B.; Bonomo, F.; Riedl, R.
2018-05-01
The ITER neutral beam system will be equipped with large radio frequency (RF) driven negative ion sources, with a cross section of 0.9 m × 1.9 m, which have to deliver extracted D- ion beams of 57 A at 1 MeV for 1 h. On the extraction from a large ion source experiment test facility, a source of half of this size is being operational since 2013. The goal of this experiment is to demonstrate a high operational reliability and to achieve the extracted current densities and beam properties required for ITER. Technical improvements of the source design and the RF system were necessary to provide reliable operation in steady state with an RF power of up to 300 kW. While in short pulses the required D- current density has almost been reached, the performance in long pulses is determined in particular in Deuterium by inhomogeneous and unstable currents of co-extracted electrons. By application of refined caesium evaporation and distribution procedures, and reduction and symmetrization of the electron currents, considerable progress has been made and up to 190 A/m2 D-, corresponding to 66% of the value required for ITER, have been extracted for 45 min.
Packaging of structural health monitoring components
NASA Astrophysics Data System (ADS)
Kessler, Seth S.; Spearing, S. Mark; Shi, Yong; Dunn, Christopher T.
2004-07-01
Structural Health Monitoring (SHM) technologies have the potential to realize economic benefits in a broad range of commercial and defense markets. Previous research conducted by Metis Design and MIT has demonstrated the ability of Lamb waves methods to provide reliable information regarding the presence, location and type of damage in composite specimens. The present NSF funded program was aimed to study manufacturing, packaging and interface concepts for critical SHM components. The intention is to be able to cheaply manufacture robust actuating/sensing devices, and isolate them from harsh operating environments including natural, mechanical, or electrical extremes. Currently the issues related to SHM system durability have remained undressed. During the course of this research several sets of test devices were fabricated and packaged to protect the piezoelectric component assemblies for robust operation. These assemblies were then tested in hot and wet conditions, as well as in electrically noisy environments. Future work will aim to package the other supporting components such as the battery and wireless chip, as well as integrating all of these components together for operation. SHM technology will enable the reduction or complete elimination of scheduled inspections, and will allow condition-based maintenance for increased reliability and reduced overall life-cycle costs.
Reliability Modeling of Microelectromechanical Systems Using Neural Networks
NASA Technical Reports Server (NTRS)
Perera. J. Sebastian
2000-01-01
Microelectromechanical systems (MEMS) are a broad and rapidly expanding field that is currently receiving a great deal of attention because of the potential to significantly improve the ability to sense, analyze, and control a variety of processes, such as heating and ventilation systems, automobiles, medicine, aeronautical flight, military surveillance, weather forecasting, and space exploration. MEMS are very small and are a blend of electrical and mechanical components, with electrical and mechanical systems on one chip. This research establishes reliability estimation and prediction for MEMS devices at the conceptual design phase using neural networks. At the conceptual design phase, before devices are built and tested, traditional methods of quantifying reliability are inadequate because the device is not in existence and cannot be tested to establish the reliability distributions. A novel approach using neural networks is created to predict the overall reliability of a MEMS device based on its components and each component's attributes. The methodology begins with collecting attribute data (fabrication process, physical specifications, operating environment, property characteristics, packaging, etc.) and reliability data for many types of microengines. The data are partitioned into training data (the majority) and validation data (the remainder). A neural network is applied to the training data (both attribute and reliability); the attributes become the system inputs and reliability data (cycles to failure), the system output. After the neural network is trained with sufficient data. the validation data are used to verify the neural networks provided accurate reliability estimates. Now, the reliability of a new proposed MEMS device can be estimated by using the appropriate trained neural networks developed in this work.
NASA Technical Reports Server (NTRS)
Smith, T. B., III; Lala, J. H.
1984-01-01
The FTMP architecture is a high reliability computer concept modeled after a homogeneous multiprocessor architecture. Elements of the FTMP are operated in tight synchronism with one another and hardware fault-detection and fault-masking is provided which is transparent to the software. Operating system design and user software design is thus greatly simplified. Performance of the FTMP is also comparable to that of a simplex equivalent due to the efficiency of fault handling hardware. The FTMP project constructed an engineering module of the FTMP, programmed the machine and extensively tested the architecture through fault injection and other stress testing. This testing confirmed the soundness of the FTMP concepts.
NASA Technical Reports Server (NTRS)
Gernand, Jeffrey L.; Gillespie, Amanda M.; Monaghan, Mark W.; Cummings, Nicholas H.
2010-01-01
Success of the Constellation Program's lunar architecture requires successfully launching two vehicles, Ares I/Orion and Ares V/Altair, within a very limited time period. The reliability and maintainability of flight vehicles and ground systems must deliver a high probability of successfully launching the second vehicle in order to avoid wasting the on-orbit asset launched by the first vehicle. The Ground Operations Project determined which ground subsystems had the potential to affect the probability of the second launch and allocated quantitative availability requirements to these subsystems. The Ground Operations Project also developed a methodology to estimate subsystem reliability, availability, and maintainability to ensure that ground subsystems complied with allocated launch availability and maintainability requirements. The verification analysis developed quantitative estimates of subsystem availability based on design documentation, testing results, and other information. Where appropriate, actual performance history was used to calculate failure rates for legacy subsystems or comparative components that will support Constellation. The results of the verification analysis will be used to assess compliance with requirements and to highlight design or performance shortcomings for further decision making. This case study will discuss the subsystem requirements allocation process, describe the ground systems methodology for completing quantitative reliability, availability, and maintainability analysis, and present findings and observation based on analysis leading to the Ground Operations Project Preliminary Design Review milestone.
Advanced Grid-Friendly Controls Demonstration Project for Utility-Scale PV Power Plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gevorgian, Vahan; O'Neill, Barbara
A typical photovoltaic (PV) power plant consists of multiple power electronic inverters and can contribute to grid stability and reliability through sophisticated 'grid-friendly' controls. The availability and dissemination of actual test data showing the viability of advanced utility-scale PV controls among all industry stakeholders can leverage PV's value from being simply an energy resource to providing additional ancillary services that range from variability smoothing and frequency regulation to power quality. Strategically partnering with a selected utility and/or PV power plant operator is a key condition for a successful demonstration project. The U.S. Department of Energy's (DOE's) Solar Energy Technologies Officemore » selected the National Renewable Energy Laboratory (NREL) to be a principal investigator in a two-year project with goals to (1) identify a potential partner(s), (2) develop a detailed scope of work and test plan for a field project to demonstrate the gird-friendly capabilities of utility-scale PV power plants, (3) facilitate conducting actual demonstration tests, and (4) disseminate test results among industry stakeholders via a joint NREL/DOE publication and participation in relevant technical conferences. The project implementation took place in FY 2014 and FY 2015. In FY14, NREL established collaborations with AES and First Solar Electric, LLC, to conduct demonstration testing on their utility-scale PV power plants in Puerto Rico and Texas, respectively, and developed test plans for each partner. Both Puerto Rico Electric Power Authority and the Electric Reliability Council of Texas expressed interest in this project because of the importance of such advanced controls for the reliable operation of their power systems under high penetration levels of variable renewable generation. During FY15, testing was completed on both plants, and a large amount of test data was produced and analyzed that demonstrates the ability of PV power plants to provide various types of new grid-friendly controls.« less
Highly Reliable PON Optical Splitters for Optical Access Networks in Outside Environments
NASA Astrophysics Data System (ADS)
Watanabe, Hiroshi; Araki, Noriyuki; Fujimoto, Hisashi
Broadband optical access services are spreading throughout the world, and the number of fiber to the home (FTTH) subscribers is increasing rapidly. Telecom operators are constructing passive optical networks (PONs) to provide optical access services. Externally installed optical splitters for PONs are very important passive devices in optical access networks, and they must provide satisfactory performance as outdoor plant over long periods. Therefore, we calculate the failure rate of optical access networks and assign a failure rate to the optical splitters in optical access networks. The maximum cumulative failure rate of 1 × 8 optical splitters was calculated as 0.025 for an optical access fiber length of 2.1km and a 20-year operating lifetime. We examined planar lightwave circuit (PLC) type optical splitters for use as outside plant in terms of their optical characteristics and environmental reliability. We confirmed that PLC type optical splitters have sufficient optical performance for a PON splitter and sufficient reliability as outside plant in accordance with ITU-T standard values. We estimated the lifetimes of three kinds of PLC type optical splitters by using accelerated aging tests. The estimated failure rate of these splitters installed in optical access networks was below the target value for the cumulative failure rate, and we confirmed that they have sufficient reliability to maintain the quality of the network service. We developed 1 × 8 optical splitter modules with plug and socket type optical connectors and optical fiber cords for optical aerial closures designed for use as outside plant. These technologies make it easy to install optical splitters in an aerial optical closure. The optical splitter modules have sufficient optical performance levels for PONs because the insertion loss at the commercially used wavelengths of 1.31 and 1.55µm is less than the criterion established by ITU-T Recommendation G.671 for optical splitters. We performed a temperature cycling test, and a low temperature storage and damp heat test to confirm the long-term reliability of these modules. They exhibited sufficient reliability as regards heat and moisture because the maximum loss change was less than 0.3dB.
Mechanization of and experience with a triplex fly-by-wire backup control system
NASA Technical Reports Server (NTRS)
Lock, W. P.; Petersen, W. R.; Whitman, G. B.
1975-01-01
A redundant three-axis analog control system was designed and developed to back up a digital fly-by-wire control system for an F-8C airplane. Forty-two flights, involving 58 hours of flight time, were flown by six pilots. The mechanization and operational experience with the backup control system, the problems involved in synchronizing it with the primary system, and the reliability of the system are discussed. The backup control system was dissimilar to the primary system, and it provided satisfactory handling through the flight envelope evaluated. Limited flight tests of a variety of control tasks showed that control was also satisfactory when the backup control system was controlled by a minimum-displacement (force) side stick. The operational reliability of the F-8 digital fly-by-wire control system was satisfactory, with no unintentional downmodes to the backup control system in flight. The ground and flight reliability of the system's components is discussed.
NASA Technical Reports Server (NTRS)
Sproles, Darrell W.; Bavuso, Salvatore J.
1994-01-01
The Hybrid Automated Reliability Predictor (HARP) integrated Reliability (HiRel) tool system for reliability/availability prediction offers a toolbox of integrated reliability/availability programs that can be used to customize the user's application in a workstation or nonworkstation environment. HiRel consists of interactive graphical input/output programs and four reliability/availability modeling engines that provide analytical and simulative solutions to a wide host of highly reliable fault-tolerant system architectures and is also applicable to electronic systems in general. The tool system was designed at the outset to be compatible with most computing platforms and operating systems and some programs have been beta tested within the aerospace community for over 8 years. This document is a user's guide for the HiRel graphical postprocessor program HARPO (HARP Output). HARPO reads ASCII files generated by HARP. It provides an interactive plotting capability that can be used to display alternate model data for trade-off analyses. File data can also be imported to other commercial software programs.
Improvements on the stability and operation of a magnetron H - ion source
Sosa, A.; Bollinger, D. S.; Karns, P. R.; ...
2017-05-31
The magnetron H - ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated offline test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its temperature dependence. A new cesium oven was designed and tested in order to avoid glass pieces that were present with the previous oven, improve thermal insulation and fine tune its temperature. Amore » current-regulated arc modulator was developed to run the ion source at a constant arc current, providing very stable beam outputs during operations. In order to reduce beam noise, the addition of small amounts of N 2 gas was explored, as well as testing different cathode shapes with increasing plasma volume. This study summarizes the studies and modifications done in the source over the last three years with the aim of improving its stability, reliability and overall performance.« less
Improvements on the stability and operation of a magnetron H- ion source
NASA Astrophysics Data System (ADS)
Sosa, A.; Bollinger, D. S.; Karns, P. R.; Tan, C. Y.
2017-05-01
The magnetron H- ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated off-line test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its temperature dependence. A new cesium oven was designed and tested in order to avoid glass pieces that were present with the previous oven, improve thermal insulation and fine-tune its temperature. A current-regulated arc modulator was developed to run the ion source at a constant arc current, providing very stable beam outputs during operations. In order to reduce beam noise, the addition of small amounts of N2 gas was explored, as well as testing different cathode shapes with increasing plasma volume. This paper summarizes the studies and modifications done in the source over the past three years with the aim of improving its stability, reliability and overall performance.
Improvements on the stability and operation of a magnetron H - ion source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sosa, A.; Bollinger, D. S.; Karns, P. R.
The magnetron H - ion sources developed in the 1970s currently in operation at Fermilab provide beam to the rest of the accelerator complex. A series of modifications to these sources have been tested in a dedicated offline test stand with the aim of improving different operational issues. The solenoid type gas valve was tested as an alternative to the piezoelectric gas valve in order to avoid its temperature dependence. A new cesium oven was designed and tested in order to avoid glass pieces that were present with the previous oven, improve thermal insulation and fine tune its temperature. Amore » current-regulated arc modulator was developed to run the ion source at a constant arc current, providing very stable beam outputs during operations. In order to reduce beam noise, the addition of small amounts of N 2 gas was explored, as well as testing different cathode shapes with increasing plasma volume. This study summarizes the studies and modifications done in the source over the last three years with the aim of improving its stability, reliability and overall performance.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patton, A.D.; Ayoub, A.K.; Singh, C.
1982-07-01
Existing methods for generating capacity reliability evaluation do not explicitly recognize a number of operating considerations which may have important effects in system reliability performance. Thus, current methods may yield estimates of system reliability which differ appreciably from actual observed reliability. Further, current methods offer no means of accurately studying or evaluating alternatives which may differ in one or more operating considerations. Operating considerations which are considered to be important in generating capacity reliability evaluation include: unit duty cycles as influenced by load cycle shape, reliability performance of other units, unit commitment policy, and operating reserve policy; unit start-up failuresmore » distinct from unit running failures; unit start-up times; and unit outage postponability and the management of postponable outages. A detailed Monte Carlo simulation computer model called GENESIS and two analytical models called OPCON and OPPLAN have been developed which are capable of incorporating the effects of many operating considerations including those noted above. These computer models have been used to study a variety of actual and synthetic systems and are available from EPRI. The new models are shown to produce system reliability indices which differ appreciably from index values computed using traditional models which do not recognize operating considerations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hacke, Peter; Lokanath, Sumanth; Williams, Paul
Data indicate that the inverter is the element of the photovoltaic plant that has the highest number of service calls and the greatest operation and maintenance cost burden. This paper describes the projects and relevant background needed in developing design qualification standards that would serve to establish a minimum level of reliability, along with a review of photovoltaic inverter quality and safety standards, most of which are in their infancy. We compare stresses and levels for accelerated testing of inverters proposed in the standard drafts, and those proposed by manufacturers and purchasers of inverters. We also review bases for themore » methods, stress types, and stress levels for durability testing of key inverter components. Many of the test protocols appear to need more comprehensive inclusion of stress factors existing in the natural environment such as wind driven rain, dust, and grid disturbances. Further understanding of how temperature, humidity ingress, and voltage bias affect the inverters and their components is also required. We provide data indicating inconsistent quality of the inverters and the durability of components leading to greater cost for the photovoltaic plant operator. Accordingly, the recommendation for data collection within quality standards for obtaining cost of ownership metrics is made. Design validation testing using realistic operation, environmental, and connection conditions, including under end-use field conditions with feedback for continuous improvement is recommended for inclusion within a quality standard.« less
Hacke, Peter; Lokanath, Sumanth; Williams, Paul; ...
2017-10-10
Data indicate that the inverter is the element of the photovoltaic plant that has the highest number of service calls and the greatest operation and maintenance cost burden. This paper describes the projects and relevant background needed in developing design qualification standards that would serve to establish a minimum level of reliability, along with a review of photovoltaic inverter quality and safety standards, most of which are in their infancy. We compare stresses and levels for accelerated testing of inverters proposed in the standard drafts, and those proposed by manufacturers and purchasers of inverters. We also review bases for themore » methods, stress types, and stress levels for durability testing of key inverter components. Many of the test protocols appear to need more comprehensive inclusion of stress factors existing in the natural environment such as wind driven rain, dust, and grid disturbances. Further understanding of how temperature, humidity ingress, and voltage bias affect the inverters and their components is also required. We provide data indicating inconsistent quality of the inverters and the durability of components leading to greater cost for the photovoltaic plant operator. Accordingly, the recommendation for data collection within quality standards for obtaining cost of ownership metrics is made. Design validation testing using realistic operation, environmental, and connection conditions, including under end-use field conditions with feedback for continuous improvement is recommended for inclusion within a quality standard.« less
Stirling Convertor Extended Operation Testing and Data Analysis at GRC
NASA Technical Reports Server (NTRS)
Cornell, Peggy A.; Lewandowski, Edward J.; Oriti, Salvatore M.; Wilson, Scott D.
2009-01-01
This paper focuses on extended operation testing and data analysis of free-piston Stirling convertors at the NASA Glenn Research Center (GRC). Extended operation testing is essential to the development of radioisotope power systems and their potential use for long duration missions. To document the reliability of the convertors, regular monitoring and analysis of the extended operation data is particularly valuable; allowing us to better understand and quantity the long life characteristics of the convertors. Further, investigation and comparison of the extended operation data to baseline performance data provides us an opportunity for understanding system behavior should any off-nominal performance occur. GRC currently has 14 Stirling convertors under 24-hour unattended extended operation testing, including two operating the Advanced Stirling Radioisotope Generator Engineering Unit (ASRG-EU). 10 of the 14 Stirling convertors at GRC are the Advanced Stirling Convertors (ASC) developed by Sunpower, Incorporated. These are highly efficient (up to > 33.5% conversion efficiency), low mass convertors that have evolved through technologically progressive convertor builds. The remaining four convertors at GRC are Technology Demonstration Convertors (TDC) from Infinia Corporation. They have achieved> 27% conversion efficiency and have accumulated over 178,000 of the total 250,622 hours of extended operation currently at GRC. A synopsis of the Stirling convertor extended operation testing and data analysis at NASA GRC is presented in this paper, as well as how this testing has contributed to the Stirling convertor's progression toward flight.
Optimal Discrete Event Supervisory Control of Aircraft Gas Turbine Engines
NASA Technical Reports Server (NTRS)
Litt, Jonathan (Technical Monitor); Ray, Asok
2004-01-01
This report presents an application of the recently developed theory of optimal Discrete Event Supervisory (DES) control that is based on a signed real measure of regular languages. The DES control techniques are validated on an aircraft gas turbine engine simulation test bed. The test bed is implemented on a networked computer system in which two computers operate in the client-server mode. Several DES controllers have been tested for engine performance and reliability.
Optimal Wind Power Uncertainty Intervals for Electricity Market Operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Ying; Zhou, Zhi; Botterud, Audun
It is important to select an appropriate uncertainty level of the wind power forecast for power system scheduling and electricity market operation. Traditional methods hedge against a predefined level of wind power uncertainty, such as a specific confidence interval or uncertainty set, which leaves the questions of how to best select the appropriate uncertainty levels. To bridge this gap, this paper proposes a model to optimize the forecast uncertainty intervals of wind power for power system scheduling problems, with the aim of achieving the best trade-off between economics and reliability. Then we reformulate and linearize the models into a mixedmore » integer linear programming (MILP) without strong assumptions on the shape of the probability distribution. In order to invest the impacts on cost, reliability, and prices in a electricity market, we apply the proposed model on a twosettlement electricity market based on a six-bus test system and on a power system representing the U.S. state of Illinois. The results show that the proposed method can not only help to balance the economics and reliability of the power system scheduling, but also help to stabilize the energy prices in electricity market operation.« less
Non-Invasive Tension Measurement Devices for Parachute Cordage
NASA Technical Reports Server (NTRS)
Litteken, Douglas A.; Daum, Jared S.
2016-01-01
The need for lightweight and non-intrusive tension measurements has arisen alongside the development of high-fidelity computer models of textile and fluid dynamics. In order to validate these computer models, data must be gathered in the operational environment without altering the design, construction, or performance of the test article. Current measurement device designs rely on severing a cord and breaking the load path to introduce a load cell. These load cells are very reliable, but introduce an area of high stiffness in the load path, directly affecting the structural response, adding excessive weight, and possibly altering the dynamics of the parachute during a test. To capture the required data for analysis validation without affecting the response of the system, non-invasive measurement devices have been developed and tested by NASA. These tension measurement devices offer minimal impact to the mass, form, fit, and function of the test article, while providing reliable, axial tension measurements for parachute cordage.
Heavy Gas Conversion of the NASA Langley Transonic Dynamics Tunnel
NASA Technical Reports Server (NTRS)
Corliss, James M.; Cole, Stanley, R.
1998-01-01
The heavy gas test medium has recently been changed in the Transonic Dynamics Tunnel (TDT) at the NASA Langley Research Center. A NASA Construction of Facilities project has converted the TDT heavy gas from dichlorodifluoromethane (R12) to 1,1,1,2 tetrafluoroethane (R134a). The facility s heavy gas processing system was extensively modified to implement the conversion to R134a. Additional system modifications have improved operator interfaces, hardware reliability, and quality of the research data. The facility modifications included improvements to the heavy gas compressor and piping, the cryogenic heavy gas reclamation system, and the heavy gas control room. A series of wind tunnel characterization and calibration tests are underway. Results of the flow characterization tests show the TDT operating envelope in R134a to be very similar to the previous operating envelope in R12.
High-voltage terminal test of a test stand for a 1-MV electrostatic accelerator
NASA Astrophysics Data System (ADS)
Park, Sae-Hoon; Kim, Yu-Seok
2015-10-01
The Korea Multipurpose Accelerator Complex has been developing a 300-kV test stand for a 1-MV electrostatic accelerator ion source. The ion source and accelerating tube will be installed in a high-pressure vessel. The ion source in the high-pressure vessel is required to have a high reliability. The test stand has been proposed and developed to confirm the stable operating conditions of the ion source. The ion source will be tested at the test stand to verify the long-time operating conditions. The test stand comprises a 300-kV high-voltage terminal, a battery for the ion-source power, a 60-Hz inverter, 200-MHz radio-frequency power supply, a 5-kV extraction power supply, a 300-kV accelerating tube, and a vacuum system. The results of the 300-kV high-voltage terminal tests are presented in this paper.
NEXT Thruster Component Verification Testing
NASA Technical Reports Server (NTRS)
Pinero, Luis R.; Sovey, James S.
2007-01-01
Component testing is a critical part of thruster life validation activities under NASA s Evolutionary Xenon Thruster (NEXT) project testing. The high voltage propellant isolators were selected for design verification testing. Even though they are based on a heritage design, design changes were made because the isolators will be operated under different environmental conditions including temperature, voltage, and pressure. The life test of two NEXT isolators was therefore initiated and has accumulated more than 10,000 hr of operation. Measurements to date indicate only a negligibly small increase in leakage current. The cathode heaters were also selected for verification testing. The technology to fabricate these heaters, developed for the International Space Station plasma contactor hollow cathode assembly, was transferred to Aerojet for the fabrication of the NEXT prototype model ion thrusters. Testing the contractor-fabricated heaters is necessary to validate fabrication processes for high reliability heaters. This paper documents the status of the propellant isolator and cathode heater tests.
CTEPP STANDARD OPERATING PROCEDURE FOR TRANSLATING VIDEOTAPES OF CHILD ACTIVITIES (SOP-4.13)
The EPA will conduct a two-day video translation workshop to demonstrate to coders the procedures for translating the activity patterns of preschool children on videotape. The coders will be required to pass reliability tests to successfully complete the training requirements of ...
Validity of a novel computerized screening test system for mild cognitive impairment.
Park, Jin-Hyuck; Jung, Minye; Kim, Jongbae; Park, Hae Yean; Kim, Jung-Ran; Park, Ji-Hyuk
2018-06-20
ABSTRACTBackground:The mobile screening test system for screening mild cognitive impairment (mSTS-MCI) was developed for clinical use. However, the clinical usefulness of mSTS-MCI to detect elderly with MCI from those who are cognitively healthy has yet to be validated. Moreover, the comparability between this system and traditional screening tests for MCI has not been evaluated. The purpose of this study was to examine the validity and reliability of the mSTS-MCI and confirm the cut-off scores to detect MCI. The data were collected from 107 healthy elderly people and 74 elderly people with MCI. Concurrent validity was examined using the Korean version of Montreal Cognitive Assessment (MoCA-K) as a gold standard test, and test-retest reliability was investigated using 30 of the study participants at four-week intervals. The sensitivity, specificity, positive predictive value, and negative predictive value (NPV) were confirmed through Receiver Operating Characteristic (ROC) analysis, and the cut-off scores for elderly people with MCI were identified. Concurrent validity showed statistically significant correlations between the mSTS-MCI and MoCA-K and test-rests reliability indicated high correlation. As a result of screening predictability, the mSTS-MCI had a higher NPV than the MoCA-K. The mSTS-MCI was identified as a system with a high degree of validity and reliability. In addition, the mSTS-MCI showed high screening predictability, indicating it can be used in the clinical field as a screening test system for mild cognitive impairment.
Robotic Assembly of Truss Structures for Space Systems and Future Research Plans
NASA Technical Reports Server (NTRS)
Doggett, William
2002-01-01
Many initiatives under study by both the space science and earth science communities require large space systems, i.e. with apertures greater than 15 m or dimensions greater than 20 m. This paper reviews the effort in NASA Langley Research Center's Automated Structural Assembly Laboratory which laid the foundations for robotic construction of these systems. In the Automated Structural Assembly Laboratory reliable autonomous assembly and disassembly of an 8 meter planar structure composed of 102 truss elements covered by 12 panels was demonstrated. The paper reviews the hardware and software design philosophy which led to reliable operation during weeks of near continuous testing. Special attention is given to highlight the features enhancing assembly reliability.
Nakagami, Katsuyuki; Yamauchi, Toyoaki; Noguchi, Hiroyuki; Maeda, Tohru; Nakagami, Tomoko
2014-06-01
This study aimed to develop a reliable and valid measure of functional health literacy in a Japanese clinical setting. Test development consisted of three phases: generation of an item pool, consultation with experts to assess content validity, and comparison with external criteria (the Japanese Health Knowledge Test) to assess criterion validity. A trial version of the test was administered to 535 Japanese outpatients. Internal consistency reliability, calculated by Cronbach's alpha, was 0.81, and concurrent validity was moderate. Receiver Operating Characteristics and Item Response Theory were used to classify patients as having adequate, marginal, or inadequate functional health literacy. Both inadequate and marginal functional health literacy were associated with older age, lower income, lower educational attainment, and poor health knowledge. The time required to complete the test was 10-15 min. This test should enable health workers to better identify patients with inadequate health literacy. © 2013 Wiley Publishing Asia Pty Ltd.
Predicting space telerobotic operator training performance from human spatial ability assessment
NASA Astrophysics Data System (ADS)
Liu, Andrew M.; Oman, Charles M.; Galvan, Raquel; Natapoff, Alan
2013-11-01
Our goal was to determine whether existing tests of spatial ability can predict an astronaut's qualification test performance after robotic training. Because training astronauts to be qualified robotics operators is so long and expensive, NASA is interested in tools that can predict robotics performance before training begins. Currently, the Astronaut Office does not have a validated tool to predict robotics ability as part of its astronaut selection or training process. Commonly used tests of human spatial ability may provide such a tool to predict robotics ability. We tested the spatial ability of 50 active astronauts who had completed at least one robotics training course, then used logistic regression models to analyze the correlation between spatial ability test scores and the astronauts' performance in their evaluation test at the end of the training course. The fit of the logistic function to our data is statistically significant for several spatial tests. However, the prediction performance of the logistic model depends on the criterion threshold assumed. To clarify the critical selection issues, we show how the probability of correct classification vs. misclassification varies as a function of the mental rotation test criterion level. Since the costs of misclassification are low, the logistic models of spatial ability and robotic performance are reliable enough only to be used to customize regular and remedial training. We suggest several changes in tracking performance throughout robotics training that could improve the range and reliability of predictive models.
Marques, Alda; Almeida, Sara; Carvalho, Joana; Cruz, Joana; Oliveira, Ana; Jácome, Cristina
2016-12-01
To assess the reliability, validity, and ability to identify fall status of the Balance Evaluation Systems Test (BESTest), Mini-BESTest, and Brief-BESTest, compared with the Berg Balance Scale (BBS), in older people living in the community. Cross-sectional. Community centers. Older adults (N=122; mean age ± SD, 76±9y). Not applicable. Participants reported on falls history in the preceding year and completed the Activities-Specific Balance Confidence (ABC) Scale. The BBS, BESTest, and the Five Times Sit-To-Stand Test were administered. Interrater (2 physiotherapists) and test-retest relative (48-72h) and absolute reliabilities were explored with the intraclass correlation coefficient (ICC) equation (2,1) and the Bland and Altman method. Minimal detectable changes at the 95% confidence level (MDC 95 ) were established. Validity was assessed by correlating the balance tests with each other and with the ABC Scale (Spearman correlation coefficients-ρ). Receiver operating characteristics assessed the ability of each balance test to differentiate between people with and without a history of falls. All balance tests presented good to excellent interrater (ICC=.71-.93) and test-retest (ICC=.50-.82) relative reliability, with no evidence of bias. MDC 95 values were 4.6, 9, 3.8, and 4.1 points for the BBS, BESTest, Mini-BESTest, and Brief-BESTest, respectively. All tests were significantly correlated with each other (ρ=.83-.96) and with the ABC Scale (ρ=.46-.61). Acceptable ability to identify fall status (areas under the curve, .71-.78) was found for all tests. Cutoff points were 48.5, 82, 19.5, and 12.5 points for the BBS, BESTest, Mini-BESTest, and Brief-BESTest, respectively. All balance tests are reliable, valid, and able to identify fall status in older people living in the community. Therefore, the choice of which test to use will depend on the level of balance impairment, purpose, and time availability. Copyright © 2016. Published by Elsevier Inc.
Quantifying the Economic and Grid Reliability Impacts of Improved Wind Power Forecasting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Qin; Martinez-Anido, Carlo Brancucci; Wu, Hongyu
Wind power forecasting is an important tool in power system operations to address variability and uncertainty. Accurately doing so is important to reducing the occurrence and length of curtailment, enhancing market efficiency, and improving the operational reliability of the bulk power system. This research quantifies the value of wind power forecasting improvements in the IEEE 118-bus test system as modified to emulate the generation mixes of Midcontinent, California, and New England independent system operator balancing authority areas. To measure the economic value, a commercially available production cost modeling tool was used to simulate the multi-timescale unit commitment (UC) and economicmore » dispatch process for calculating the cost savings and curtailment reductions. To measure the reliability improvements, an in-house tool, FESTIV, was used to calculate the system's area control error and the North American Electric Reliability Corporation Control Performance Standard 2. The approach allowed scientific reproducibility of results and cross-validation of the tools. A total of 270 scenarios were evaluated to accommodate the variation of three factors: generation mix, wind penetration level, and wind fore-casting improvements. The modified IEEE 118-bus systems utilized 1 year of data at multiple timescales, including the day-ahead UC, 4-hour-ahead UC, and 5-min real-time dispatch. The value of improved wind power forecasting was found to be strongly tied to the conventional generation mix, existence of energy storage devices, and the penetration level of wind energy. The simulation results demonstrate that wind power forecasting brings clear benefits to power system operations.« less
Structural Testing of the Blade Reliability Collaborative Effect of Defect Wind Turbine Blades
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desmond, M.; Hughes, S.; Paquette, J.
Two 8.3-meter (m) wind turbine blades intentionally constructed with manufacturing flaws were tested to failure at the National Wind Technology Center (NWTC) at the National Renewable Energy Laboratory (NREL) south of Boulder, Colorado. Two blades were tested; one blade was manufactured with a fiberglass spar cap and the second blade was manufactured with a carbon fiber spar cap. Test loading primarily consisted of flap fatigue loading of the blades, with one quasi-static ultimate load case applied to the carbon fiber spar cap blade. Results of the test program were intended to provide the full-scale test data needed for validation ofmore » model and coupon test results of the effect of defects in wind turbine blade composite materials. Testing was part of the Blade Reliability Collaborative (BRC) led by Sandia National Laboratories (SNL). The BRC seeks to develop a deeper understanding of the causes of unexpected blade failures (Paquette 2012), and to develop methods to enable blades to survive to their expected operational lifetime. Recent work in the BRC includes examining and characterizing flaws and defects known to exist in wind turbine blades from manufacturing processes (Riddle et al. 2011). Recent results from reliability databases show that wind turbine rotor blades continue to be a leading contributor to turbine downtime (Paquette 2012).« less
Initial operation of a solar heating and cooling system in a full-scale solar building test facility
NASA Technical Reports Server (NTRS)
Knoll, R. H.; Miao, D.; Hamlet, I. L.; Jensen, R. N.
1976-01-01
The Solar Building Test Facility (SBTF) located at Hampton, Virginia became operational in early summer of 1976. This facility is a joint effort by NASA-Lewis and NASA-Langley to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test performance of complete solar heating and cooling system, (3) investigate component interactions and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is given here, along with the objectives, test approach, expected system performance and some preliminary results.
Spatial and Temporal Analysis of Bias HAST System Temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pfeifer, Kent B.; Furrer, III, Clint T; Sandoval, Paul Anthony
2017-03-01
High-reliability components for high-consequence systems require detailed testing of operation after having undergone highly accelerated stress testing (HAST) under unusual conditions of high-temperature and humidity. This paper describes the design and operation of a system called "Wormwood" that is a highly multiplexed temperature measurement system that is designed to operate under HAST conditions to allow measurement of the temperature as a function of time and position in a HAST chamber. HAST chambers have single-point temperature measurements that can be traceable to NIST standards. The objective of these "Wormwood" measurements is to verify the uniformity and stability of the remaining volumemore » of the HAST chamber with respect to the single traceable standard.« less
NASA Technical Reports Server (NTRS)
Kleinhammer, Roger K.; Graber, Robert R.; DeMott, D. L.
2016-01-01
Reliability practitioners advocate getting reliability involved early in a product development process. However, when assigned to estimate or assess the (potential) reliability of a product or system early in the design and development phase, they are faced with lack of reasonable models or methods for useful reliability estimation. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, analysts attempt to develop the "best" or composite analog data to support the assessments. Industries, consortia and vendors across many areas have spent decades collecting, analyzing and tabulating fielded item and component reliability performance in terms of observed failures and operational use. This data resource provides a huge compendium of information for potential use, but can also be compartmented by industry, difficult to find out about, access, or manipulate. One method used incorporates processes for reviewing these existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component. It can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. It also establishes a baseline prior that may updated based on test data or observed operational constraints and failures, i.e., using Bayesian techniques. This tutorial presents a descriptive compilation of historical data sources across numerous industries and disciplines, along with examples of contents and data characteristics. It then presents methods for combining failure information from different sources and mathematical use of this data in early reliability estimation and analyses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chu, Tsong-Lun; Varuttamaseni, Athi; Baek, Joo-Seok
The U.S. Nuclear Regulatory Commission (NRC) encourages the use of probabilistic risk assessment (PRA) technology in all regulatory matters, to the extent supported by the state-of-the-art in PRA methods and data. Although much has been accomplished in the area of risk-informed regulation, risk assessment for digital systems has not been fully developed. The NRC established a plan for research on digital systems to identify and develop methods, analytical tools, and regulatory guidance for (1) including models of digital systems in the PRAs of nuclear power plants (NPPs), and (2) incorporating digital systems in the NRC's risk-informed licensing and oversight activities.more » Under NRC's sponsorship, Brookhaven National Laboratory (BNL) explored approaches for addressing the failures of digital instrumentation and control (I and C) systems in the current NPP PRA framework. Specific areas investigated included PRA modeling digital hardware, development of a philosophical basis for defining software failure, and identification of desirable attributes of quantitative software reliability methods. Based on the earlier research, statistical testing is considered a promising method for quantifying software reliability. This paper describes a statistical software testing approach for quantifying software reliability and applies it to the loop-operating control system (LOCS) of an experimental loop of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL).« less
Butler, Emily E; Saville, Christopher W N; Ward, Robert; Ramsey, Richard
2017-01-01
The human face cues a range of important fitness information, which guides mate selection towards desirable others. Given humans' high investment in the central nervous system (CNS), cues to CNS function should be especially important in social selection. We tested if facial attractiveness preferences are sensitive to the reliability of human nervous system function. Several decades of research suggest an operational measure for CNS reliability is reaction time variability, which is measured by standard deviation of reaction times across trials. Across two experiments, we show that low reaction time variability is associated with facial attractiveness. Moreover, variability in performance made a unique contribution to attractiveness judgements above and beyond both physical health and sex-typicality judgements, which have previously been associated with perceptions of attractiveness. In a third experiment, we empirically estimated the distribution of attractiveness preferences expected by chance and show that the size and direction of our results in Experiments 1 and 2 are statistically unlikely without reference to reaction time variability. We conclude that an operating characteristic of the human nervous system, reliability of information processing, is signalled to others through facial appearance. Copyright © 2016 Elsevier B.V. All rights reserved.
The application of the statistical theory of extreme values to gust-load problems
NASA Technical Reports Server (NTRS)
Press, Harry
1950-01-01
An analysis is presented which indicates that the statistical theory of extreme values is applicable to the problems of predicting the frequency of encountering the larger gust loads and gust velocities for both specific test conditions as well as commercial transport operations. The extreme-value theory provides an analytic form for the distributions of maximum values of gust load and velocity. Methods of fitting the distribution are given along with a method of estimating the reliability of the predictions. The theory of extreme values is applied to available load data from commercial transport operations. The results indicate that the estimates of the frequency of encountering the larger loads are more consistent with the data and more reliable than those obtained in previous analyses. (author)
Upgrades to the ISS Water Recovery System
NASA Technical Reports Server (NTRS)
Kayatin, Matthew J.; Carter, Donald L.; Schunk, Richard G.; Pruitt, Jennifer M.
2016-01-01
The International Space Station Water Recovery System (WRS) is comprised of the Water Processor Assembly (WPA) and the Urine Processor Assembly (UPA). The WRS produces potable water from a combination of crew urine (first processed through the UPA), crew latent, and Sabatier product water. Though the WRS has performed well since operations began in November 2008, several modifications have been identified to improve the overall system performance. These modifications can reduce resupply and improve overall system reliability, which is beneficial for the ongoing ISS mission as well as for future NASA manned missions. The following paper details efforts to reduce the resupply mass of the WPA Multifiltration Bed, develop improved catalyst for the WPA Catalytic Reactor, evaluate optimum operation of UPA through parametric testing, and improve reliability of the UPA fluids pump and Distillation Assembly.
Widely tunable gas laser for remote sensing
NASA Technical Reports Server (NTRS)
Rothe, D. E.
1988-01-01
An advanced, highly efficient and reliable Rare-Gas Halide laser was developed. It employs the following: (1) novel prepulse techniques and impedance matching for efficient energy transfer; (2) magnetic switches for high reliability; (3) x-ray preionization for discharge uniformity and beam quality; and (4) an integrated gas flow loop for compactness. When operated as a XeCl laser, the unit produces 2 J per pulse with good beam uniformity. Optical pulse duration is 100 ns. Pulse repetition rate was tested up to 25 Hz. Efficiency is 3 percent.
Reliability of a new test battery for fitness assessment of the European Astronaut corps.
Petersen, Nora; Thieschäfer, Lutz; Ploutz-Snyder, Lori; Damann, Volker; Mester, Joachim
2015-01-01
To optimise health for space missions, European astronauts follow specific conditioning programs before, during and after their flights. To evaluate the effectiveness of these programs, the European Space Agency conducts an Astronaut Fitness Assessment (AFA), but the test-retest reliability of elements within it remains unexamined. The reliability study described here presents a scientific basis for implementing the AFA, but also highlights challenges faced by operational teams supporting humans in such unique environments, especially with respect to health and fitness monitoring of crew members travelling not only into space, but also across the world. The AFA tests assessed parameters known to be affected by prolonged exposure to microgravity: aerobic capacity (VO2max), muscular strength (one repetition max, 1 RM) and power (vertical jumps), core stability, flexibility and balance. Intraclass correlation coefficients (ICC3.1), standard error of measurement and coefficient of variation were used to assess relative and absolute test-retest reliability. Squat and bench 1 RM (ICC3.1 = 0.94-0.99), hip flexion (ICC3.1 = 0.99) and left and right handgrip strength (ICC3.1 = 0.95 and 0.97), showed the highest test-retest reliability, followed by VO2max (ICC3.1 = 0.91), core strength (ICC3.1 = 0.78-0.89), hip extension (ICC3.1 = 0.63), the countermeasure (ICC3.1 = 0.76) and squat (ICC3.1 = 0.63) jumps, and single right- and left-leg jump height (ICC3.1 = 0.51 and 0.14). For balance, relative reliability ranged from ICC3.1 = 0.78 for path length (two legs, head tilted back, eyes open) to ICC3.1 = 0.04 for average rotation velocity (one leg, eyes closed). In a small sample (n = 8) of young, healthy individuals, the AFA battery of tests demonstrated acceptable test-retest reliability for most parameters except some balance and single-leg jump tasks. These findings suggest that, for the application with astronauts, most AFA tests appear appropriate to be maintained in the test battery, but that some elements may be unreliable, and require either modification (duration, selection of task) or removal (single-leg jump, balance test on sphere) from the battery. The test battery is mobile and universally applicable for occupational and general fitness assessment by its comprehensive composition of tests covering many systems involved in whole body movement.
Energy Efficient Engine integrated core/low spool design and performance report
NASA Technical Reports Server (NTRS)
Stearns, E. Marshall
1985-01-01
The Energy Efficient Engine (E3) is a NASA program to create fuel saving technology for future transport aircraft engines. The E3 technology advancements were demonstrated to operate reliably and achieve goal performance in tests of the Integrated Core/Low Spool vehicle. The first build of this undeveloped technology research engine set a record for low fuel consumption. Its design and detailed test results are herein presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piekarski, D.; Brad, D.
This report is about a work effort where the overall objectives were to establish a methodology and approach for selected transmission and distribution (T&D) grid modernization; monitor the results; and report on the findings, recommendations, and lessons learned. The work reported addressed T&D problems and solutions, related reliability issues, equipment and operation upgrades, and respective field testing.
AN/ALQ-135 tail warning system follow-on operational test and evaluation
NASA Astrophysics Data System (ADS)
Jenkins, V. M.
1981-11-01
This is a study of the reliability and maintainability of the tail warning system (TWS) AN/ALQ-153. This TWS is a solid state pulsed Doppler radar designed to provide warning and initiate countermeasures against threats attacking from the tail of B-52G/H aircraft.
14 CFR 171.113 - Installation requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... facilities. (c) The facility must have a reliable source of suitable primary power, either from a power distribution system or locally generated. Also, adequate power capacity must be provided for operation of test... a facility will be required to have standby power for the SDF and monitor accessories to supplement...
14 CFR 171.113 - Installation requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... facilities. (c) The facility must have a reliable source of suitable primary power, either from a power distribution system or locally generated. Also, adequate power capacity must be provided for operation of test... a facility will be required to have standby power for the SDF and monitor accessories to supplement...
14 CFR 171.113 - Installation requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... facilities. (c) The facility must have a reliable source of suitable primary power, either from a power distribution system or locally generated. Also, adequate power capacity must be provided for operation of test... a facility will be required to have standby power for the SDF and monitor accessories to supplement...
29 CFR 1910.164 - Fire detection systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... fire detectors and fire detection systems are tested and adjusted as often as needed to maintain proper reliability and operating condition except that factory calibrated detectors need not be adjusted after...) The employer shall also assure that fire detectors that need to be cleaned of dirt, dust, or other...
29 CFR 1910.164 - Fire detection systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... fire detectors and fire detection systems are tested and adjusted as often as needed to maintain proper reliability and operating condition except that factory calibrated detectors need not be adjusted after...) The employer shall also assure that fire detectors that need to be cleaned of dirt, dust, or other...
29 CFR 1910.164 - Fire detection systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... fire detectors and fire detection systems are tested and adjusted as often as needed to maintain proper reliability and operating condition except that factory calibrated detectors need not be adjusted after...) The employer shall also assure that fire detectors that need to be cleaned of dirt, dust, or other...
29 CFR 1910.164 - Fire detection systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... fire detectors and fire detection systems are tested and adjusted as often as needed to maintain proper reliability and operating condition except that factory calibrated detectors need not be adjusted after...) The employer shall also assure that fire detectors that need to be cleaned of dirt, dust, or other...
29 CFR 1910.164 - Fire detection systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... fire detectors and fire detection systems are tested and adjusted as often as needed to maintain proper reliability and operating condition except that factory calibrated detectors need not be adjusted after...) The employer shall also assure that fire detectors that need to be cleaned of dirt, dust, or other...
Integrated Human-in-the-Loop Ground Testing - Value, History, and the Future
NASA Technical Reports Server (NTRS)
Henninger, Donald L.
2016-01-01
Systems for very long-duration human missions to Mars will be designed to operate reliably for many years and many of these systems will never be returned to Earth. The need for high reliability is driven by the requirement for safe functioning of remote, long-duration crewed systems and also by unsympathetic abort scenarios. Abort from a Mars mission could be as long as 450 days to return to Earth. The key to developing a human-in-the-loop architecture is a development process that allows for a logical sequence of validating successful development in a stepwise manner, with assessment of key performance parameters (KPPs) at each step; especially important are KPPs for technologies evaluated in a full systems context with human crews on Earth and on space platforms such as the ISS. This presentation will explore the implications of such an approach to technology development and validation including the roles of ground and space-based testing necessary to develop a highly reliable system for long duration human exploration missions. Historical development and systems testing from Mercury to the International Space Station (ISS) to ground testing will be reviewed. Current work as well as recommendations for future work will be described.
In vitro and in vivo testing of a totally implantable left ventricular assist system.
Jassawalla, J S; Daniel, M A; Chen, H; Lee, J; LaForge, D; Billich, J; Ramasamy, N; Miller, P J; Oyer, P E; Portner, P M
1988-01-01
The totally implantable Novacor LVAS is being tested under NIH auspices to demonstrate safety and efficacy before clinical trials. Twelve complete systems (submerged in saline at 37 degrees C) are being tested, with an NIH goal of demonstrating 80% reliability for 2 year operation with a 60% confidence level. The systems, which are continuously monitored, are diurnally cycled between two output levels by automatically varying preload and afterload. Currently, 14.3 years of failure-free operation have been accumulated, with a mean duration of 14 months. Using an exponential failure distribution model, the mean time to failure (MTTF) is greater than 8.8 years, corresponding to a demonstrated reliability (for a 2 year mission time) of 80% (80% confidence level). Recent ovine experiments with VAS subsystems include a 767 day volume compensator implant, a 279 day pump/drive unit implant and a 1,448 day BST implant. The last 12 chronic pump/drive unit experiments had a mean duration of 153 days (excluding early postoperative complications). This compares favorably with the NIH goals for complete systems (5 month mean duration). Complete system experiments are currently underway.
Andersen, Kenneth Geving; Kehlet, Henrik; Aasvang, Eske Kvanner
2015-05-01
Quantitative sensory testing (QST) is used to assess sensory dysfunction and nerve damage by examining psychophysical responses to controlled, graded stimuli such as mechanical and thermal detection and pain thresholds. In the breast cancer population, 4 studies have used QST to examine persistent pain after breast cancer treatment, suggesting neuropathic pain being a prominent pain mechanism. However, the agreement and reliability of QST has not been described in the postsurgical breast cancer population, hindering exact interpretation of QST studies in this population. The aim of the present study was to assess test-retest properties of QST after breast cancer surgery. A total of 32 patients recruited from a larger ongoing prospective trial were examined with QST 12 months after breast cancer surgery and reexamined a week later. A standardized QST protocol was used, including sensory mapping for mechanical, warmth and cold areas of sensory dysfunction, mechanical thresholds using monofilaments and pin-prick, thermal thresholds including warmth and cold detection thresholds and heat pain threshold, with bilateral examination. Agreement and reliability were assessed by Bland-Altman plots, descriptive statistics, coefficients of variance, and intraclass correlation. Bland-Altman plots showed high variation on the surgical side. Intraclass coefficients ranged from 0.356 to 0.847 (moderate to substantial reliability). Between-patient variation was generally higher (0.9 to 14.5 SD) than within-patient variation (0.23 to 3.55 SD). There were no significant differences between pain and pain-free patients. The individual test-retest variability was higher on the operated side compared with the nonoperated side. The QST protocol reliability allows for group-to-group comparison of sensory function, but less so for individual follow-up after breast cancer surgery.
Performance of Lung Ultrasound in Detecting Peri-Operative Atelectasis after General Anesthesia.
Yu, Xin; Zhai, Zhenping; Zhao, Yongfeng; Zhu, Zhiming; Tong, Jianbin; Yan, Jianqin; Ouyang, Wen
2016-12-01
The aim of this prospective observational study was to evaluate the performance of lung ultrasound (LUS) in detecting post-operative atelectasis in adult patients under general anesthesia. Forty-six patients without pulmonary comorbidities who were scheduled for elective neurosurgery were enrolled in the study. A total of 552 pairs of LUS clips and thoracic computed tomography (CT) images were ultimately analyzed to determine the presence of atelectasis in 12 prescribed lung regions. The accuracy of LUS in detecting peri-operative atelectasis was evaluated with thoracic CT as gold standard. Levels of agreement between the two observers for LUS and the two observers for thoracic CT were analyzed using the κ reliability test. The quantitative correlation between LUS scores of aeration and the volumetric data of atelectasis in thoracic CT were further evaluated. LUS had reliable performance in post-operative atelectasis, with a sensitivity of 87.7%, specificity of 92.1% and diagnostic accuracy of 90.8%. The levels of agreement between the two observers for LUS and for thoracic CT were both satisfactory, with κ coefficients of 0.87 (p < 0.0001) and 0.93 (p < 0.0001), respectively. In patients in the supine position, LUS scores were highly correlated with the atelectasis volume of CT (r = 0.58, p < 0.0001). Thus, LUS provides a fast, reliable and radiation-free method to identify peri-operative atelectasis in adults. Copyright © 2016. Published by Elsevier Inc.
The LSLE echocardiograph - Commercial hardware aboard Spacelab. [Life Sciences Laboratory Equipment
NASA Technical Reports Server (NTRS)
Schwarz, R.
1983-01-01
The Life Sciences Laboratory Equipment Echocardiograph, a commercial 77020AC Ultrasound Imaging System modified to meet NASA's spacecraft standards, is described. The assembly consists of four models: display and control, scanner, scan converter, and physioamplifiers. Four separate processors communicate over an IEE-488 bus, and the system has more than 6000 individual components on 35 printed circuit cards. Three levels of self test are provided: a short test during power up, a basic test initiated by a front panel switch, and interactive tests for specific routines. Default mode operation further enhances reliability. Modifications of the original system include the replacement of ac power supplies with dc to dc converters, a slide-out keyboard (to prevent accidental operation), Teflon insulated wire, and additional shielding for the ultrasound transducer cable.
NASA Astrophysics Data System (ADS)
Winebrenner, D. P.; Elam, W. T.; Carpenter, M.; Kintner, P., III
2014-12-01
More numerous observations within and beneath ice sheets are needed to address a broad variety of important questions concerning ice sheets and climate. However, emplacement of instruments continues to be constrained by logistical burdens, especially in cold ice a kilometer or more thick. Electrically powered thermal melt probes are inherently logistically light and efficient, especially for reaching greater depths in colder ice. They therefore offer a means of addressing current measurement problems, but have been limited historically by a lack of technology for reliable operation at the necessary voltages and powers. Here we report field tests in Greenland of two new melt probes. We operated one probe at 2.2 kilowatts (kW) and 1050 volts (V), achieving a depth of 400 m in the ice in ~ 120 hours, without electrical failure. That depth is the second greatest achieved thus far with a thermal melt probe, exceeded only by one deployment to 1005 m in Greenland in 1968, which ended in an electrical failure. Our test run took place in two intervals separated by a year, with the probe frozen at 65 m depth during the interim, after which we re-established communication, unfroze the probe, and proceeded to the greater depth. During the second field test we operated a higher-power probe, initially at 2.5 kW and 1500 V and progressing to 4.5 kW and 2000 V. Initial data indicate that this probe achieved a descent rate of 8 m/hr, which if correct would be the fastest rate yet achieved for such probes. Moreover, we observed maintenance of vertical probe travel using pendulum steering throughout both tests, as well as autonomous descent without operator-intervention after launch. The latter suggests potential for crews of 1-2 to operate several melt probes concurrently. However, the higher power probe did suffer electrical failure of a heating element after 7 hours of operation at 2000 V (24 hours after the start of the test), contrary to expectations based on laboratory component and system testing. We are therefore revising the probe heaters using a newer but more development-intensive technology. With probe systems now validated in our tests, this will result in a reliable means to emplace instruments for studies of subglacial hydrology, ice dynamics, and possible subglacial ecologies.
Stirling Convertor Fasteners Reliability Quantification
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Korovaichuk, Igor; Kovacevich, Tiodor; Schreiber, Jeffrey G.
2006-01-01
Onboard Radioisotope Power Systems (RPS) being developed for NASA s deep-space science and exploration missions require reliable operation for up to 14 years and beyond. Stirling power conversion is a candidate for use in an RPS because it offers a multifold increase in the conversion efficiency of heat to electric power and reduced inventory of radioactive material. Structural fasteners are responsible to maintain structural integrity of the Stirling power convertor, which is critical to ensure reliable performance during the entire mission. Design of fasteners involve variables related to the fabrication, manufacturing, behavior of fasteners and joining parts material, structural geometry of the joining components, size and spacing of fasteners, mission loads, boundary conditions, etc. These variables have inherent uncertainties, which need to be accounted for in the reliability assessment. This paper describes these uncertainties along with a methodology to quantify the reliability, and provides results of the analysis in terms of quantified reliability and sensitivity of Stirling power conversion reliability to the design variables. Quantification of the reliability includes both structural and functional aspects of the joining components. Based on the results, the paper also describes guidelines to improve the reliability and verification testing.
Validation of the Dementia Care Assessment Packet-Instrumental Activities of Daily Living
Lee, Seok Bum; Park, Jeong Ran; Yoo, Jeong-Hwa; Park, Joon Hyuk; Lee, Jung Jae; Yoon, Jong Chul; Jhoo, Jin Hyeong; Lee, Dong Young; Woo, Jong Inn; Han, Ji Won; Huh, Yoonseok; Kim, Tae Hui
2013-01-01
Objective We aimed to evaluate the psychometric properties of the IADL measure included in the Dementia Care Assessment Packet (DCAP-IADL) in dementia patients. Methods The study involved 112 dementia patients and 546 controls. The DCAP-IADL was scored in two ways: observed score (OS) and predicted score (PS). The reliability of the DCAP-IADL was evaluated by testing its internal consistency, inter-rater reliability and test-retest reliability. Discriminant validity was evaluated by comparing the mean OS and PS between dementia patients and controls by ANCOVA. Pearson or Spearman correlation analysis was performed with other instruments to assess concurrent validity. Receiver operating characteristics curve analysis was performed to examine diagnostic accuracy. Results Chronbach's α coefficients of the DCAP-IADL were above 0.7. The values in dementia patients were much higher (OS=0.917, PS=0.927), indicating excellent degrees of internal consistency. Inter-rater reliabilities and test-retest reliabilities were statistically significant (p<0.05). PS exhibited higher reliabilities than OS. The mean OS and PS of dementia patients were significantly higher than those of the non-demented group after controlling for age, sex and education level. The DCAP-IADL was significantly correlated with other IADL instruments and MMSE-KC (p<0.001). Areas under the curves of the DCAP-IADL were above 0.9. Conclusion The DCAP-IADL is a reliable and valid instrument for evaluating instrumental ability of daily living for the elderly, and may also be useful for screening dementia. Moreover, administering PS may enable the DCAP-IADL to overcome the differences in gender, culture and life style that hinders accurate evaluation of the elderly in previous IADL instruments. PMID:24302946
NASA Technical Reports Server (NTRS)
Belcastro, Celeste M.
1989-01-01
Digital control systems for applications such as aircraft avionics and multibody systems must maintain adequate control integrity in adverse as well as nominal operating conditions. For example, control systems for advanced aircraft, and especially those with relaxed static stability, will be critical to flight and will, therefore, have very high reliability specifications which must be met regardless of operating conditions. In addition, multibody systems such as robotic manipulators performing critical functions must have control systems capable of robust performance in any operating environment in order to complete the assigned task reliably. Severe operating conditions for electronic control systems can result from electromagnetic disturbances caused by lightning, high energy radio frequency (HERF) transmitters, and nuclear electromagnetic pulses (NEMP). For this reason, techniques must be developed to evaluate the integrity of the control system in adverse operating environments. The most difficult and illusive perturbations to computer-based control systems that can be caused by an electromagnetic environment (EME) are functional error modes that involve no component damage. These error modes are collectively known as upset, can occur simultaneously in all of the channels of a redundant control system, and are software dependent. Upset studies performed to date have not addressed the assessment of fault tolerant systems and do not involve the evaluation of a control system operating in a closed-loop with the plant. A methodology for performing a real-time simulation of the closed-loop dynamics of a fault tolerant control system with a simulated plant operating in an electromagnetically harsh environment is presented. In particular, considerations for performing upset tests on the controller are discussed. Some of these considerations are the generation and coupling of analog signals representative of electromagnetic disturbances to a control system under test, analog data acquisition, and digital data acquisition from fault tolerant systems. In addition, a case study of an upset test methodology for a fault tolerant electromagnetic aircraft engine control system is presented.
Highly-efficient, frequency-tripled Nd:YAG laser for spaceborne LIDARs
NASA Astrophysics Data System (ADS)
Treichel, R.; Hoffmann, H.-D.; Luttmann, J.; Morasch, V.; Nicklaus, K.; Wührer, C.
2017-11-01
For a spaceborne lidar a highly reliable, long living and efficient laser source is absolutely essential. Within the frame of the development of a laser source for the backscatter lidar ATLID, which will be flown on EarthCare mission, we setup and tested a predevelopment model of an injection-seeded, diode pumped, frequency tripled, pulsed high power Nd:YAG MOPA laser operating nominally at 100 Hz pulse repetition frequency. We also tested the burst operation mode. The excellent measured performance parameter will be introduced. The oscillator rod is longitudinally pumped from both sides. The oscillator has been operated with three cavity control methods: "Cavity Dither", "Pound-Drever-Hall" and "Adaptive Ramp & Fire". Especially the latter method is very suitable to operate the laser in harsh vibrating environment such in airplanes. The amplifier bases on the InnoSlab design concept. The constant keeping of a moderate fluence in the InnoSlab crystal permits excellent possibilities to scale the pulse energy to several 100 mJ. An innovative pump unit and optics makes the laser performance insensitive to inhomogeneous diode degradation and allows switching of additional redundant diodes. Further key features have been implemented in a FM design concept. The operational lifetime is extended by the implementation of internal redundancies for the most critical parts. The reliability is increased due to the higher margin onto the laser induced damage threshold by a pressurized housing. Additionally air-to-vacuum effects becomes obsolete. A high efficient heat removal concept has been implemented.
Initial operation of a solar heating and cooling system in a full-scale solar building test facility
NASA Technical Reports Server (NTRS)
Knoll, R. H.; Miao, D.; Hamlet, I. L.; Jensen, R. N.
1976-01-01
The Solar Building Test Facility (SBTF) was constructed to advance the technology for heating and cooling of office buildings with solar energy. Its purposes are to (1) test system components which include high-performing collectors, (2) test the performance of a complete solar heating and cooling system, (3) investigate component interactions, and (4) investigate durability, maintenance and reliability of components. The SBTF consists of a 50,000 square foot office building modified to accept solar heated water for operation of an absorption air conditioner and for the baseboard heating system. A 12,666 square foot solar collector field with a 30,000 gallon storage tank provides the solar heated water. A description of the system and the collectors selected is printed along with the objectives, test approach, expected system performance, and some preliminary results.
Alternatives to ozone depleting refrigerants in test equipment
NASA Technical Reports Server (NTRS)
Hall, Richard L.; Johnson, Madeleine R.
1995-01-01
This paper describes the initial results of a refrigerant retrofit project at the Aerospace Guidance and Metrology Center (AGMC) at Newark Air Force Base, Ohio. The objective is to convert selected types of test equipment to properly operate on hydrofluorocarbon (HFC) alternative refrigerants, having no ozone depleting potential, without compromising system reliability or durability. This paper discusses the primary technical issues and summarizes the test results for 17 different types of test equipment: ten environmental chambers, two ultralow temperature freezers, two coolant recirculators, one temperature control unit, one vapor degreaser, and one refrigerant recovery system. The postconversion performance test results have been very encouraging: system capacity and input power remained virtually unchanged. In some cases, the minimum operating temperature increased by a few degrees as a result of the conversion, but never beyond AGMC's functional requirements.
Magellan attitude and articulation control subsystem closed loop testing
NASA Technical Reports Server (NTRS)
Olschansky, David G.
1987-01-01
In the spring of 1989, the Magellan spacecraft will embark on a two-year mission to map the surface of the planet Venus. Guiding it there will be the Attitude and Articulation Control Subsystem (AACS). To ensure reliable operations the AACS is being put through a rigorous test program at Martin Marietta Denver Aerospace. Before Magellan ever leaves the Space Shuttle bay from which it is to be launched, its components will have flown a simulated spaceflight in a ground-based lab. The primary objectives of the test program are to verify form, fit, and function of the AACS, particularly subsystem external interfaces and functional operation of the flight software. This paper discusses the Magellan Closed Loop Test Systems which makes realistic tests possible by simulating the dynamic and 'visual' flight environment for AACS components in the lab.
Methodology to identify risk-significant components for inservice inspection and testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, M.T.; Hartley, R.S.; Jones, J.L. Jr.
1992-08-01
Periodic inspection and testing of vital system components should be performed to ensure the safe and reliable operation of Department of Energy (DOE) nuclear processing facilities. Probabilistic techniques may be used to help identify and rank components by their relative risk. A risk-based ranking would allow varied DOE sites to implement inspection and testing programs in an effective and cost-efficient manner. This report describes a methodology that can be used to rank components, while addressing multiple risk issues.
Test-retest reliability of posture measurements in adolescents with idiopathic scoliosis.
Heitz, Pierre-Henri; Aubin-Fournier, Jean-François; Parent, Éric; Fortin, Carole
2018-05-07
Posture changes are a major consequence of IS (IS). Posture changes can lead to psychosocial and physical impairments in adolescents with IS. Therefore, it is important to assess posture but the test-retest reliability of posture measurements still remains unknown in this population. The primary objective was to determine the test-retest reliability of 25 head and trunk posture indices using the Clinical Photographic Postural Assessment Tool (CPPAT) in adolescents with IS. The secondary objective was to determine the standard error of measurement and the minimal detectable change. This is a prospective test-retest reliability study carried out at two tertiary university hospital centers. Forty-one adolescents with IS, aged 10 to 16 years old with curves 10 to 45 o and treated non-operatively were recruited. Two posture assessments were done using the CPPAT five to 10 days apart following a standardized procedure. Photographs were analyzed with the CPPAT software by digitizing reference landmarks placed on the participant by a physiotherapist evaluator. Generalizability theory was used to obtain a coefficient of dependability, standard error of measurement and the minimal detectable change at the 90% confidence interval. This project was supported by the Canadian Pediatric Spine Society (CPSS: 10000$). There is no study-specific conflicts of interest-associated biases. Fourteen of 25 posture indices had a good reliability (ϕ ≥ 0.78), ten of 25 had moderate reliability (ϕ = 0.55 to 0.74) and one had poor reliability (ϕ = 0.45). The most reliable posture indices were waist angles asymmetry (ϕ = 0.93), right waist angle (ϕ = 0.91) and frontal trunk list (ϕ = 0.92). Right sagittal trunk list was the least reliable posture index (ϕ = 0.45). The MDC 90 values ranged from 2.6 to 10.3° for angular measurements and from 8.4 to 35.1 mm for linear measurements. This study demonstrates that most posture indices, especially the trunk posture indices, are reproducible in time among adolescents with IS and provides reference values. Clinicians and researchers can use these reference values in order to assess change in posture over time attributable to treatment effectiveness. Copyright © 2018. Published by Elsevier Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baumgarten, C.; Barchetti, A.; Einenkel, H.
2011-05-15
A compact electron cyclotron resonance proton source has been developed and installed recently at thePaul Scherrer Institute's high intensity proton accelerator. Operation at the ion source test stand and the accelerator demonstrates a high reliability and stability of the new source. When operated at a 10 - 12 mA net proton current the lifetime of the source exceeds 2000 h. The essential development steps towards the observed performance are described.
Vlasov, A A; Vazhenin, A V; Plotnikov, V V; Spirev, V V; Chinarev, Iu B
2010-01-01
The study is concerned with development of equipment for forming circular compression intestinal anastomosis using the "form memory" effect and super-elasticity of titanium nickelide. A sequence of technological operations is suggested, experimental tests and clinical trials carried out and immediate and end-results for anterior resection in rectal cancer are evaluated. Compression equipment for forming colorectal anastomosis proved reliable in long-term operation.
del Pozo-Cruz, Borja; Mocholi, Miguel H; del Pozo-Cruz, Jesus; Parraca, Jose A; Adsuar, Jose C; Gusi, Narcis
2014-01-01
Despite the widespread use of trunk endurance tests, the reliability and validity of these tests in office workers with subacute nonspecific low back pain are unknown. This cross-sectional study involved 190 subjects: 30 men and 42 women without low back pain and 47 men and 71 women with low back pain. All subjects underwent timed prone and supine isometric lumbar and abdominal trunk endurance tests that were performed until subjective fatigue occurred. All subjects also completed the Roland Morris and Oswestry self-reported disability questionnaires. A test-retest study (7 days) was conducted with 31 participants with low back pain from the study. For the abdominal trunk endurance test, males and females with low back pain had mean (SD) values of 62.06 (36.87) and 46.06 (29.28) seconds, respectively, both significantly lower than the asymptomatic workers. For the lumbar test, males and females with low back pain had mean (SD) values of 79.57 (30.66) and 75.49 (28.97) seconds, respectively, again, both significantly lower than the asymptomatic workers. The intraclass correlation coefficients of both tests exceeded 0.90 and the Kappa indices were excellent for both men and women. Receiver-operating curve analyses revealed areas under the curve very close to or exceeding 0.70 for both men and women for both tests. The lumbar and abdominal trunk muscle endurance tests appeared to be reliable and valid measures in office workers with subacute low back pain.
Proposal and validation of a clinical trunk control test in individuals with spinal cord injury.
Quinzaños, J; Villa, A R; Flores, A A; Pérez, R
2014-06-01
One of the problems that arise in spinal cord injury (SCI) is alteration in trunk control. Despite the need for standardized scales, these do not exist for evaluating trunk control in SCI. To propose and validate a trunk control test in individuals with SCI. National Institute of Rehabilitation, Mexico. The test was developed and later evaluated for reliability and criteria, content, and construct validity. We carried out 531 tests on 177 patients and found high inter- and intra-rater reliability. In terms of criterion validity, analysis of variance demonstrated a statistically significant difference in the test score of patients with adequate or inadequate trunk control according to the assessment of a group of experts. A receiver operating characteristic curve was plotted for optimizing the instrument's cutoff point, which was determined at 13 points, with a sensitivity of 98% and a specificity of 92.2%. With regard to construct validity, the correlation between the proposed test and the spinal cord independence measure (SCIM) was 0.873 (P=0.001) and that with the evolution time was 0.437 (P=0.001). For testing the hypothesis with qualitative variables, the Kruskal-Wallis test was performed, which resulted in a statistically significant difference between the scores in the proposed scale of each group defined by these variables. It was proven experimentally that the proposed trunk control test is valid and reliable. Furthermore, the test can be used for all patients with SCI despite the type and level of injury.
Reisner, A. T.; Khitrov, M. Y.; Chen, L.; Blood, A.; Wilkins, K.; Doyle, W.; Wilcox, S.; Denison, T.; Reifman, J.
2013-01-01
Summary Background Advanced decision-support capabilities for prehospital trauma care may prove effective at improving patient care. Such functionality would be possible if an analysis platform were connected to a transport vital-signs monitor. In practice, there are technical challenges to implementing such a system. Not only must each individual component be reliable, but, in addition, the connectivity between components must be reliable. Objective We describe the development, validation, and deployment of the Automated Processing of Physiologic Registry for Assessment of Injury Severity (APPRAISE) platform, intended to serve as a test bed to help evaluate the performance of decision-support algorithms in a prehospital environment. Methods We describe the hardware selected and the software implemented, and the procedures used for laboratory and field testing. Results The APPRAISE platform met performance goals in both laboratory testing (using a vital-sign data simulator) and initial field testing. After its field testing, the platform has been in use on Boston MedFlight air ambulances since February of 2010. Conclusion These experiences may prove informative to other technology developers and to healthcare stakeholders seeking to invest in connected electronic systems for prehospital as well as in-hospital use. Our experiences illustrate two sets of important questions: are the individual components reliable (e.g., physical integrity, power, core functionality, and end-user interaction) and is the connectivity between components reliable (e.g., communication protocols and the metadata necessary for data interpretation)? While all potential operational issues cannot be fully anticipated and eliminated during development, thoughtful design and phased testing steps can reduce, if not eliminate, technical surprises. PMID:24155791
Stirling Convertor Extended Operation Testing and Data Analysis at Glenn Research Center
NASA Technical Reports Server (NTRS)
Cornell, Peggy A.; Lewandowski, Edward J.; Oriti, Salvatore M.; Wilson, Scott D.
2010-01-01
Extended operation of Stirling convertors is essential to the development of radioisotope power systems and their potential use for longduration missions. To document the reliability of the convertors, regular monitoring and analysis of the extended operation data is particularly valuable, allowing us to better understand and quantify long-life characteristics of the convertors. Furthermore, investigation and comparison of the extended operation data to baseline performance data provides an opportunity to understand system behavior should any off-nominal performance occur. Glenn Research Center (GRC) has tested 16 Stirling convertors under 24-hr unattended extended operation, including four that have operated in a thermal vacuum environment and two that are operating in the Advanced Stirling Radioisotope Generator Engineering Unit. Ten of the sixteen convertors are the Advanced Stirling Convertors (ASC) developed by Sunpower, Inc. with GRC. These are highly efficient (conversion efficiency of up to 38 percent for the ASC-1), low-mass convertors that have evolved through technologically progressive convertor builds. Six convertors at GRC are Technology Demonstration Convertors from Infinia Corporation. They have achieved greater than 27 percent conversion efficiency and have accumulated over 185,000 of the total 265,000 hr of extended operation at GRC. This paper presents the extended operation testing and data analysis of free-piston Stirling convertors at NASA GRC as well as how these tests have contributed to the Stirling convertor s progression toward flight.
Configuration management issues and objectives for a real-time research flight test support facility
NASA Technical Reports Server (NTRS)
Yergensen, Stephen; Rhea, Donald C.
1988-01-01
An account is given of configuration management activities for the Western Aeronautical Test Range (WATR) at NASA-Ames, whose primary function is the conduct of aeronautical research flight testing through real-time processing and display, tracking, and communications systems. The processing of WATR configuration change requests for specific research flight test projects must be conducted in such a way as to refrain from compromising the reliability of WATR support to all project users. Configuration management's scope ranges from mission planning to operations monitoring and performance trend analysis.
Mandillo, Silvia; Tucci, Valter; Hölter, Sabine M.; Meziane, Hamid; Banchaabouchi, Mumna Al; Kallnik, Magdalena; Lad, Heena V.; Nolan, Patrick M.; Ouagazzal, Abdel-Mouttalib; Coghill, Emma L.; Gale, Karin; Golini, Elisabetta; Jacquot, Sylvie; Krezel, Wojtek; Parker, Andy; Riet, Fabrice; Schneider, Ilka; Marazziti, Daniela; Auwerx, Johan; Brown, Steve D. M.; Chambon, Pierre; Rosenthal, Nadia; Tocchini-Valentini, Glauco; Wurst, Wolfgang
2008-01-01
Establishing standard operating procedures (SOPs) as tools for the analysis of behavioral phenotypes is fundamental to mouse functional genomics. It is essential that the tests designed provide reliable measures of the process under investigation but most importantly that these are reproducible across both time and laboratories. For this reason, we devised and tested a set of SOPs to investigate mouse behavior. Five research centers were involved across France, Germany, Italy, and the UK in this study, as part of the EUMORPHIA program. All the procedures underwent a cross-validation experimental study to investigate the robustness of the designed protocols. Four inbred reference strains (C57BL/6J, C3HeB/FeJ, BALB/cByJ, 129S2/SvPas), reflecting their use as common background strains in mutagenesis programs, were analyzed to validate these tests. We demonstrate that the operating procedures employed, which includes open field, SHIRPA, grip-strength, rotarod, Y-maze, prepulse inhibition of acoustic startle response, and tail flick tests, generated reproducible results between laboratories for a number of the test output parameters. However, we also identified several uncontrolled variables that constitute confounding factors in behavioral phenotyping. The EUMORPHIA SOPs described here are an important start-point for the ongoing development of increasingly robust phenotyping platforms and their application in large-scale, multicentre mouse phenotyping programs. PMID:18505770
Large Engine Technology Program. Task 22: Variable Geometry Concepts for Rich-Quench-Lean Combustors
NASA Technical Reports Server (NTRS)
Tacina, Robert R. (Technical Monitor); Cohen, J. M.; Padget, F. C.; Kwoka, D.; Wang, Q.; Lohmann, R. P.
2005-01-01
The objective of the task reported herein was to define, evaluate, and optimize variable geometry concepts suitable for use with a Rich-Quench-Lean (RQL) combustor. The specific intent was to identify approaches that would satisfy High Speed Civil Transport (HSCT) cycle operational requirements with regard to fuel-air ratio turndown capability, ignition, and stability margin without compromising the stringent emissions, performance, and reliability goals that this combustor would have to achieve. Four potential configurations were identified and three of these were refined and tested in a high-pressure modular RQL combustor rig. The tools used in the evolution of these concepts included models built with rapid fabrication techniques that were tested for airflow characteristics to confirm sizing and airflow management capability, spray patternation, and atomization characterization tests of these models and studies that were supported by Computational Fluid Dynamics analyses. Combustion tests were performed with each of the concepts at supersonic cruise conditions and at other critical conditions in the flight envelope, including the transition points of the variable geometry system, to identify performance, emissions, and operability impacts. Based upon the cold flow characterization, emissions results, acoustic behavior observed during the tests and consideration of mechanical, reliability, and implementation issues, the tri-swirler configuration was selected as the best variable geometry concept for incorporation in the RQL combustor evolution efforts for the HSCT.
77 FR 24594 - Version 4 Critical Infrastructure Protection Reliability Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-25
... framework for the identification and protection of ``Critical Cyber Assets'' to support the reliable... documentation of Critical Cyber Assets associated with ``Critical Assets'' that support the reliable operation... ``Critical Cyber Assets'' that are associated with ``Critical Assets'' to support the reliable operation of...
Ion accelerator systems for high power 30 cm thruster operation
NASA Technical Reports Server (NTRS)
Aston, G.
1982-01-01
Two and three-grid accelerator systems for high power ion thruster operation were investigated. Two-grid translation tests show that over compensation of the 30 cm thruster SHAG grid set spacing the 30 cm thruster radial plasma density variation and by incorporating grid compensation only sufficient to maintain grid hole axial alignment, it is shown that beam current gains as large as 50% can be realized. Three-grid translation tests performed with a simulated 30 cm thruster discharge chamber show that substantial beamlet steering can be reliably affected by decelerator grid translation only, at net-to-total voltage ratios as low as 0.05.
Characterization of the NEXT Hollow Cathode Inserts After Long-Duration Testing
NASA Technical Reports Server (NTRS)
Mackey, J.; Shastry, R.; Soulas, G.
2017-01-01
Hollow dispenser cathode inserts are a critical element of electric propulsion systems, and should therefore be well understood during long term operation to ensure reliable system performance. This work destructively investigated cathode inserts from the NEXT long-duration test which demonstrated 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The characterization methods used include scanning electron microscopy with energy dispersive spectroscopy and X-ray diffraction. Microscopy analysis has been performed on fractured surfaces, emission surfaces, and metallographically polished cross-sections of post-test inserts and unused inserts. Impregnate distribution, etch region thickness, impregnate chemical content, emission surface topography, and emission surface phase identification are the primary factors investigated.
Thermal Vacuum Testing of a Multi-Evaporator Miniature Loop Heat Pipe
NASA Technical Reports Server (NTRS)
Ku, Jentung; Ottenstein, Laura; Nagano, Hosei
2008-01-01
Under NASA's New Millennium Program Space Technology 8 Project, four experiments are being developed for future small system applications requiring low mass, low power, and compactness. GSFC is responsible for developing the Thermal Loop experiment, which is an advanced thermal control system consisting of a miniature loop heat pipe (MLHP) with multiple evaporators and condensers. The objective is to validate the operation of an MLHP, including reliable start-ups, steady operation, heat load sharing, and tight temperature control over the range of 273K to 308K. An MLHP Breadboard has been built and tested for 1200 hours under the laboratory environment and 500 hours in a thermal vacuum chamber. Results of the TV tests are presented here.
Summary of Results from Space Shuttle Main Engine Off-Nominal Testing
NASA Technical Reports Server (NTRS)
Horton, James F.; Megivern, Jeffrey M.; McNutt, Leslie M.
2011-01-01
This paper is a summary of Space Shuttle Main Engine (SSME) off-nominal testing that occurred during 2008 and 2009. During the last two years of planned SSME testing at Stennis Space Center, Pratt & Whitney Rocketdyne worked with their NASA MSFC customer to systematically identify, develop, assess, and implement challenging test objectives in order to expand the knowledge of one of the world s most reliable and highly tested large rocket engine. The objectives successfully investigated three main areas of interest expanding engine performance margins, demonstrating system operational capabilities, and establishing ground work for new rocket engine technology. The testing gave the Space Shuttle Program new options to safely fly out the flight manifest and provided Pratt & Whitney Rocketdyne and NASA new insight into the operational capabilities of the SSME, capabilities which can be used in assessing potential future applications of the RS-25 engine.
NASA Technical Reports Server (NTRS)
Littlefield, Alan C.; Melton, Gregory S.
2000-01-01
The X-33 Advanced Technology Demonstrator is an un-piloted, vertical take-off, horizontal landing spacecraft. The purpose of the X-33 program is to demonstrate technologies that will dramatically lower the cost of access to space. The rocket-powered X-33 will reach an altitude of up to 100 km and speeds between Mach 13 and 15. Fifteen flight tests are planned, beginning in 2000. Some of the key technologies demonstrated will be the linear aerospike engine, improved thermal protection systems, composite fuel tanks and reduced operational timelines. The X-33 vehicle umbilical connections provide monitoring, power, cooling, purge, and fueling capability during horizontal processing and vertical launch operations. Two "rise-off" umbilicals for the X-33 have been developed, tested, and installed. The X-33 umbilical systems mechanisms incorporate several unique design features to simplify horizontal operations and provide reliable disconnect during launch.
NASA Technical Reports Server (NTRS)
Littlefield, Alan C.; Melton, Gregory S.
1999-01-01
The X-33 Advanced Technology Demonstrator is an un-piloted, vertical take-off, horizontal landing spacecraft. The purpose of the X-33 program is to demonstrate technologies that will dramatically lower the cost of access to space. The rocket-powered X-33 will reach an altitude of up to 100 km and speeds between Mach 13 and 15. Fifteen flight tests are planned, beginning in 2000. Some of the key technologies demonstrated will be the linear aerospike engine, improved thermal protection systems, composite fuel tanks and reduced operational timelines. The X-33 vehicle umbilical connections provide monitoring, power, cooling, purge, and fueling capability during horizontal processing and vertical launch operations. Two "rise-ofF' umbilicals for the X-33 have been developed, tested, and installed. The X-33 umbilical systems mechanisms incorporate several unique design features to simplify horizontal operations and provide reliable disconnect during launch.
Human Reliability Assessments: Using the Past (Shuttle) to Predict the Future (ORION)
NASA Technical Reports Server (NTRS)
Mott, Diana L.; Bigler, Mark A.
2017-01-01
NASA uses two HRA assessment methodologies. The first is a simplified method which is based on how much time is available to complete the action, with consideration included for environmental and personal factors that could influence the human's reliability. This method is expected to provide a conservative value or placeholder as a preliminary estimate. This preliminary estimate is used to determine which placeholder needs a more detailed assessment. The second methodology is used to develop a more detailed human reliability assessment on the performance of critical human actions. This assessment needs to consider more than the time available, this would include factors such as: the importance of the action, the context, environmental factors, potential human stresses, previous experience, training, physical design interfaces, available procedures/checklists and internal human stresses. The more detailed assessment is still expected to be more realistic than that based primarily on time available. When performing an HRA on a system or process that has an operational history, we have information specific to the task based on this history and experience. In the case of a PRA model that is based on a new design and has no operational history, providing a "reasonable" assessment of potential crew actions becomes more problematic. In order to determine what is expected of future operational parameters, the experience from individuals who had relevant experience and were familiar with the system and process previously implemented by NASA was used to provide the "best" available data. Personnel from Flight Operations, Flight Directors, Launch Test Directors, Control Room Console Operators and Astronauts were all interviewed to provide a comprehensive picture of previous NASA operations. Verification of the assumptions and expectations expressed in the assessments will be needed when the procedures, flight rules and operational requirements are developed and then finalized.
Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Chou, Willy; Chen, Kuan-Lin; Hsieh, Ching-Lin
2017-07-27
This study aimed at improving the utility of the fine motor subscale of the comprehensive developmental inventory for infants and toddlers (CDIIT) by developing a computerized adaptive test of fine motor skills. We built an item bank for the computerized adaptive test of fine motor skills using the fine motor subscale of the CDIIT items fitting the Rasch model. We also examined the psychometric properties and efficiency of the computerized adaptive test of fine motor skills with simulated computerized adaptive tests. Data from 1742 children with suspected developmental delays were retrieved. The mean scores of the fine motor subscale of the CDIIT increased along with age groups (mean scores = 1.36-36.97). The computerized adaptive test of fine motor skills contains 31 items meeting the Rasch model's assumptions (infit mean square = 0.57-1.21, outfit mean square = 0.11-1.17). For children of 6-71 months, the computerized adaptive test of fine motor skills had high Rasch person reliability (average reliability >0.90), high concurrent validity (rs = 0.67-0.99), adequate to excellent diagnostic accuracy (area under receiver operating characteristic = 0.71-1.00), and large responsiveness (effect size = 1.05-3.93). The computerized adaptive test of fine motor skills used 48-84% fewer items than the fine motor subscale of the CDIIT. The computerized adaptive test of fine motor skills used fewer items for assessment but was as reliable and valid as the fine motor subscale of the CDIIT. Implications for Rehabilitation We developed a computerized adaptive test based on the comprehensive developmental inventory for infants and toddlers (CDIIT) for assessing fine motor skills. The computerized adaptive test has been shown to be efficient because it uses fewer items than the original measure and automatically presents the results right after the test is completed. The computerized adaptive test is as reliable and valid as the CDIIT.
NASA Astrophysics Data System (ADS)
Orumbayev, R. K.; Kibarin, A. A.; Khodanova, T. V.; Korobkov, M. S.
2018-03-01
This work contains analysis of technical values of tower hot-water boiler PTVM-100 when operating on gas and oil residual. After the test it became clear that due to the construction deficiency during the combustion of oil residual, it is not possible to provide long-term production of heat. There is also given a short review on modernization of PTVM-100 hot-water boilers. With the help of calculations based on controlled all-mode mathematic modules of hot-water boilers in BOILER DESIGNER software, it was shown that boiler modernization by use of bi-radiated screens and new convective set of tubes allows decreasing sufficiently the temperature of combustor output gases and increase reliability of boiler operation. Constructive changes of boiler unit suggested by authors of this work, along with increase of boiler’s operation reliability also allow to improve it’s heat production rates and efficiency rate up to 90,5% when operating on fuel oil and outdoor installation option.
Standardization of carbon-phenolic composite test methodology
NASA Technical Reports Server (NTRS)
Hall, W. B.
1986-01-01
The objective of this study was to evaluate the residual volatiles, filler content, and resin flow test procedures for carbon-phenolic prepreg materials. The residual volatile test procedure was rewritten with tighter procedure control which was then evaluated by round robin testing by four laboratories on the same rolls of prepreg. Results indicated that the residual volatiles test was too operator and equipment dependent to be reliable, and it was recommended that the test be discontinued. The resin flow test procedures were rewritten with tighter procedure control, and it is now considered to be an acceptable test. It was recommended that the filler content determination be made prior to prepregging.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-05
..., RM13-14-000 and RM13-15-000] Monitoring System Conditions--Transmission Operations Reliability...) 502-6817, [email protected] . Robert T. Stroh (Legal Information), Office of the General... Reliability Standards ``address the important reliability goal of ensuring that the transmission system is...
Cai, Gaigai; Chen, Xuefeng; Li, Bing; Chen, Baojia; He, Zhengjia
2012-01-01
The reliability of cutting tools is critical to machining precision and production efficiency. The conventional statistic-based reliability assessment method aims at providing a general and overall estimation of reliability for a large population of identical units under given and fixed conditions. However, it has limited effectiveness in depicting the operational characteristics of a cutting tool. To overcome this limitation, this paper proposes an approach to assess the operation reliability of cutting tools. A proportional covariate model is introduced to construct the relationship between operation reliability and condition monitoring information. The wavelet packet transform and an improved distance evaluation technique are used to extract sensitive features from vibration signals, and a covariate function is constructed based on the proportional covariate model. Ultimately, the failure rate function of the cutting tool being assessed is calculated using the baseline covariate function obtained from a small sample of historical data. Experimental results and a comparative study show that the proposed method is effective for assessing the operation reliability of cutting tools. PMID:23201980
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carter, R.J.
1997-04-01
The primary purpose of the "modification and validation of an automotive data processing unit (DPU), compressed video system, and communications equipment" cooperative research and development agreement (CRADA) was to modify and validate both hardware and software, developed by Scientific Atlanta, Incorporated (S-A) for defense applications (e.g., rotary-wing airplanes), for the commercial sector surface transportation domain (i.e., automobiles and trucks). S-A also furnished a state-of-the-art compressed video digital storage and retrieval system (CVDSRS), and off-the-shelf data storage and transmission equipment to support the data acquisition system for crash avoidance research (DASCAR) project conducted by Oak Ridge National Laboratory (ORNL). In turn,more » S-A received access to hardware and technology related to DASCAR. DASCAR was subsequently removed completely and installation was repeated a number of times to gain an accurate idea of complete installation, operation, and removal of DASCAR. Upon satisfactory completion of the DASCAR construction and preliminary shakedown, ORNL provided NHTSA with an operational demonstration of DASCAR at their East Liberty, OH test facility. The demonstration included an on-the-road demonstration of the entire data acquisition system using NHTSA'S test track. In addition, the demonstration also consisted of a briefing, containing the following: ORNL generated a plan for validating the prototype data acquisition system with regard to: removal of DASCAR from an existing vehicle, and installation and calibration in other vehicles; reliability of the sensors and systems; data collection and transmission process (data integrity); impact on the drivability of the vehicle and obtrusiveness of the system to the driver; data analysis procedures; conspicuousness of the vehicle to other drivers; and DASCAR installation and removal training and documentation. In order to identify any operational problems not captured by the systems testing and evaluation, the validation plan also addressed a short-term pilot research program to manipulate DASCAR under operational conditions using "naive" drivers. The effort exercised the fill capabilities of the data acquisition system. ORNL subsequently evaluated and pilot tested the data acquisition system using the validation plan. The plan was implemented in full at the NHTSA East Liberty, OH test facility, and was carried out as a cooperative effort with the Vehicle Research and Test Center staff. ORNL determined the reliability of the sensors and systems by exercising DASCAR For one vehicle type, ORNL evaluated systems reliability over a continuous period of 30 days with particular attention paid to maintenance of calibration and data integrity.« less
Improving yield and reliability of FIB modifications using electrical testing
NASA Astrophysics Data System (ADS)
Desplats, Romain; Benbrik, Jamel; Benteo, Bruno; Perdu, Philippe
1998-08-01
Focused Ion Beam technology has two main areas of application for ICs: modification and preparation for technological analysis. The most solicited area is modification. This involves physically modifying a circuit by cutting lines and creating new ones in order to change the electrical function of the circuit. IC planar technologies have an increasing number of metal interconnections making FIB modifications more complex and decreasing their changes of success. The yield of FIB operations on ICs reflects a downward trend that imposes a greater number of circuits to be modified in order to successfully correct a small number of them. This requires extended duration, which is not compatible with production line turn around times. To respond to this problem, two solutions can be defined: either, reducing the duration of each FIB operation or increasing the success rate of FIB modifications. Since reducing the time depends mainly on FIB operator experience, insuring a higher success rate represents a more crucial aspect as both experienced and novice operators could benefit from this improvement. In order to insure successful modifications, it is necessary to control each step of a FIB operation. To do this, we have developed a new method using in situ electrical testing which has a direct impact on the yield of FIB modifications. We will present this innovative development through a real case study of a CMOS ASIC for high-speed communications. Monitoring the electrical behavior at each step in a FIB operation makes it possible to reduce the number of circuits to be modified and consequently reduces system costs thanks to better yield control. Knowing the internal electrical behavior also gives us indications about the impact on reliability of FIB modified circuits. Finally, this approach can be applied to failure analysis and FIB operations on flip chip circuits.
Development and thermal management of 10 kW CW, direct diode laser source
NASA Astrophysics Data System (ADS)
Zhu, Hongbo; Hao, Mingming; Zhang, Jianwei; Ji, Wenyu; Lin, Xingchen; Zhang, Jinsheng; Ning, Yongqiang
2016-01-01
We report on the development of direct diode laser source with high-power and high reliability. The laser source was realized by the polarization and wavelength combination of four diode laser stacks. When at the operating current of 122 A, the source was capable of producing 10,120 W output while maintaining 46% electro-optical conversion efficiency. The maximum temperature on the lens was decreased from 442.2 K to 320 K by utilizing an efficient thermal dissipation structure, and the corresponding maximum von Mises stress was reduced from 75.4 MPa to 14 MPa. In addition, a reliability test demonstrated that our laser source was reliable and potential in the applications of laser cladding and heat treatment.
NASA Technical Reports Server (NTRS)
Phoenix, S. Leigh; Kezirian, Michael T.; Murthy, Pappu L. N.
2009-01-01
Composite Overwrapped Pressure Vessel (COPVs) that have survived a long service time under pressure generally must be recertified before service is extended. Sometimes lifetime testing is performed on an actual COPV in service in an effort to validate the reliability model that is the basis for certifying the continued flight worthiness of its sisters. Currently, testing of such a Kevlar49(registered TradeMark)/epoxy COPV is nearing completion. The present paper focuses on a Bayesian statistical approach to analyze the possible failure time results of this test and to assess the implications in choosing between possible model parameter values that in the past have had significant uncertainty. The key uncertain parameters in this case are the actual fiber stress ratio at operating pressure, and the Weibull shape parameter for lifetime; the former has been uncertain due to ambiguities in interpreting the original and a duplicate burst test. The latter has been uncertain due to major differences between COPVs in the data base and the actual COPVs in service. Any information obtained that clarifies and eliminates uncertainty in these parameters will have a major effect on the predicted reliability of the service COPVs going forward. The key result is that the longer the vessel survives, the more likely the more optimistic stress ratio is correct. At the time of writing, the resulting effect on predicted future reliability is dramatic, increasing it by about one nine , that is, reducing the probability of failure by an order of magnitude. However, testing one vessel does not change the uncertainty on the Weibull shape parameter for lifetime since testing several would be necessary.
2015-05-01
multiple automated cognitive tests, data management and reporting capabilities, and executive menu. The DANA battery was given on a Trimble NOMAD ...handheld computing device using a stylus for consistency. The NOMAD runs a custom version of the Android Operating System and has a color 3.5 inch... digit pairs are shown below a key, & the participant indicates it matches the one in the key. PRO This test targets decision-making capabilities
A Primer for DoD Reliability, Maintainability, Safety, and Logistics Standards, 1992
1991-10-01
equipment, identified in the order of application (i.e., assembly, unit and system screens). Screening Strength ( SS ) - The probability that a screen...As’- ss equipment suitability for its intended operational environment. c. Verify contractual compliance. Each test method is divided into two...SIMULA-ITno Q.A. j FABRICATION, VALIDATION AD CONCERNS j PACKAGE AND SAnSFACTORY MBI Y QUALIMCATION RE UIREMENTS NO QRA TESTS YES QMLFOR TECHNOLOGY
2016-10-04
analysis (due to site-level evaluations), but could be added in the future, include: wind turbines (the installations we visited were not interested due...procurement, operation, maintenance , testing, and fueling of the generators, detailed inventory and cost data is difficult to obtain. The DPW is often...understaffed, leading to uneven testing and maintenance of the equipment despite their best efforts. The reliability of these generators is typically
Training Guide for Observation and Interviewing in Marine Corps Task Analysis. Training Manual 3
1975-08-01
McGraw- Hill Book Co., 1954. This is a comprehensive text that treats theory and sta- tistical operations in psychological testing . Chapter 14 deals...with reliability and validity of measures. -44- Reliabilitv and Validity (cont’d.) Cronbach, L., ESSENTIALS OF PSYCHOLOGICAL TESTING , 2nd ed., New...Commandant of the Marine Corps (Code RD) And Monitored By Personnel and Training Research Programs Psychological Sciences Division Office of Naval
2011-10-01
working memory),(Vanderploeg et al., 2005) Wechsler Adult Intelligence Scale III (WAIS-III) items: Digit Symbol Coding, Digit Span, Letter-Number...EFFORT William C. Walker, MD, Principal Investigator September, 2008 20 (see: VCU sub-award) David X. Cifu, MD Co-Investigator September, 2008...group for our purposes. The neuropsychological battery will consist of the following standardized, validated, tests of proven reliability: Wechsler Test
Low Temperature Testing of a Radiation Hardened CMOS 8-Bit Flash Analog-to-Digital (A/D) Converter
NASA Technical Reports Server (NTRS)
Gerber, Scott S.; Hammond, Ahmad; Elbuluk, Malik E.; Patterson, Richard L.; Overton, Eric; Ghaffarian, Reza; Ramesham, Rajeshuni; Agarwal, Shri G.
2001-01-01
Power processing electronic systems, data acquiring probes, and signal conditioning circuits are required to operate reliably under harsh environments in many of NASA:s missions. The environment of the space mission as well as the operational requirements of some of the electronic systems, such as infrared-based satellite or telescopic observation stations where cryogenics are involved, dictate the utilization of electronics that can operate efficiently and reliably at low temperatures. In this work, radiation-hard CMOS 8-bit flash A/D converters were characterized in terms of voltage conversion and offset in the temperature range of +25 to -190 C. Static and dynamic supply currents, ladder resistance, and gain and offset errors were also obtained in the temperature range of +125 to -190 C. The effect of thermal cycling on these properties for a total of ten cycles between +80 and - 150 C was also determined. The experimental procedure along with the data obtained are reported and discussed in this paper.
Extended Operation of Stirling Convertors at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Oriti, Salvatore
2011-01-01
Glenn Research Center (GRC) is supporting life and reliability database for free-piston Stirilng conversion via extended convertor operation Ongoing convertor operation: 18 convertors (4 TDCs from Infinia, 14 ASCs from Sunpower). 350,000 total convertor hours of operation. 218,000 on Infinia units and 132,000 on Sunpower units. Demonstrating steady convertor performance requires precise maintenance of operating conditions. Sources of disruption : Investigative tests: Varying operating frequency, hot-end temp, cold-end temp. Hot end control method: Constant heat input mode requires more user-adjustment than constant temperature mode. Long-term transients in hot end insulation were observed. Support facility: Open-bath circulator fluid concentration drifting. Nuisance shutdowns (instrumentation failure, EMI, power outages). Ambient temperature fluctuations due to room HVAC.
Scaled centrifugal compressor, collector and running gear program
NASA Technical Reports Server (NTRS)
Kenehan, J. G.
1983-01-01
The Scaled Centrifugal Compressor, Collector and Running gear Program was conducted in support of an overall NASA strategy to improve small-compressor performance, durability, and reliability while reducing initial and life-cycle costs. Accordingly, Garrett designed and provided a test rig, gearbox coupling, and facility collector for a new NASA facility, and provided a scaled model of an existing, high-performance impeller for evaluation scaling effects on aerodynamic performance and for obtaining other performance data. Test-rig shafting was designed to operate smoothly throughout a speed range up to 60,000 rpm. Pressurized components were designed to operate at pressures up to 300 psia and at temperatures to 1000 F. Nonrotating components were designed to provide a margin-of-safety of 0.05 or greater; rotating components, for a margin-of-safety based on allowable yield and ultimate strengths. Design activities were supported by complete design analysis, and the finished hardware was subjected to check-runs to confirm proper operation. The test rig will support a wide range of compressor tests and evaluations.
Navy applications experience with small wind power systems
NASA Astrophysics Data System (ADS)
Pal, D.
1985-05-01
This report describes the experience gained and lesson learned from the ongoing field evaluations of seven small, 2-to 20-kW wind energy conversion systems (WECS) at Navy installations located in the Southern California desert, on San Nicolas Island, in California, and in Kaneohe Bay, Hawaii. The field tests show that the WECS's bearings and yaw slip-rings are prone to failure. The failures were attributed to the corrosive environment and poor design practices. Based upon the field tests, it is concluded that a reliable WECS must use a permanent magnet alternator without a gearbox and yaw slip-rings that are driven by a fixed pitch wind turbine rotor. The present state-of-the-art in small WECS technology, including environmental concerns, is reviewed. Also presented is how the technology is advancing to improve reliability and availability for effectively using wind power at Navy bases. The field evaluations are continuing on the small WECS in order to develop operation, maintenance, and reliability data.
Reliability modeling of fault-tolerant computer based systems
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.
1987-01-01
Digital fault-tolerant computer-based systems have become commonplace in military and commercial avionics. These systems hold the promise of increased availability, reliability, and maintainability over conventional analog-based systems through the application of replicated digital computers arranged in fault-tolerant configurations. Three tightly coupled factors of paramount importance, ultimately determining the viability of these systems, are reliability, safety, and profitability. Reliability, the major driver affects virtually every aspect of design, packaging, and field operations, and eventually produces profit for commercial applications or increased national security. However, the utilization of digital computer systems makes the task of producing credible reliability assessment a formidable one for the reliability engineer. The root of the problem lies in the digital computer's unique adaptability to changing requirements, computational power, and ability to test itself efficiently. Addressed here are the nuances of modeling the reliability of systems with large state sizes, in the Markov sense, which result from systems based on replicated redundant hardware and to discuss the modeling of factors which can reduce reliability without concomitant depletion of hardware. Advanced fault-handling models are described and methods of acquiring and measuring parameters for these models are delineated.
NASA Technical Reports Server (NTRS)
Kaufman, A.; Pudick, S.; Wang, C. L.; Werth, J.; Whelan, J. A.
1984-01-01
Two 25-cell, 13 inch x 23 inch (4kW) stacks were started up to evaluate the reliability of component and stack technology developed through the end of 1983. Both stacks started up well and are running satisfactorily on hydrogen-air after 1900 hours and 800 hours, respectively. A synthetic-reformat mixing station is nearing completion, and both stacks will be operated on reformate fuel. A stack-protection control system was placed in operation for Stack No. 2, and a similar set-up is in preparation for Stack No. 1. This system serves to change operating conditions or shut the stack down to avoid deleterious effects from nonstack-related upsets. The capability will greatly improve changes of obtaining meaningful long-term test data.
Lateral Load Testing of the Advanced Stirling Convertor (ASC-E2) Heater Head
NASA Technical Reports Server (NTRS)
Cornell, Peggy A.; Krause, David L.; Davis, Glen; Robbie, Malcolm G.; Gubics, David A.
2010-01-01
Free-piston Stirling convertors are fundamental to the development of NASA s next generation of radioisotope power system, the Advanced Stirling Radioisotope Generator (ASRG). The ASRG will use General Purpose Heat Source (GPHS) modules as the energy source and Advanced Stirling Convertors (ASCs) to convert heat into electrical energy, and is being developed by Lockheed Martin under contract to the Department of Energy. Achieving flight status mandates that the ASCs satisfy design as well as flight requirements to ensure reliable operation during launch. To meet these launch requirements, GRC performed a series of quasi-static mechanical tests simulating the pressure, thermal, and external loading conditions that will be experienced by an ASC-E2 heater head assembly. These mechanical tests were collectively referred to as "lateral load tests" since a primary external load lateral to the heater head longitudinal axis was applied in combination with the other loading conditions. The heater head was subjected to the operational pressure, axial mounting force, thermal conditions, and axial and lateral launch vehicle acceleration loadings. To permit reliable prediction of the heater head s structural performance, GRC completed Finite Element Analysis (FEA) computer modeling for the stress, strain, and deformation that will result during launch. The heater head lateral load test directly supported evaluation of the analysis and validation of the design to meet launch requirements. This paper provides an overview of each element within the test and presents assessment of the modeling as well as experimental results of this task.
Lateral Load Testing of the Advanced Stirling Convertor (ASC-E2) Heater Head
NASA Technical Reports Server (NTRS)
Cornell, Peggy A.; Krause, David L.; Davis, Glen; Robbie, Malcolm G.; Gubics, David A.
2011-01-01
Free-piston Stirling convertors are fundamental to the development of NASA s next generation of radioisotope power system, the Advanced Stirling Radioisotope Generator (ASRG). The ASRG will use General Purpose Heat Source (GPHS) modules as the energy source and Advanced Stirling Convertors (ASCs) to convert heat into electrical energy, and is being developed by Lockheed Martin under contract to the Department of Energy. Achieving flight status mandates that the ASCs satisfy design as well as flight requirements to ensure reliable operation during launch. To meet these launch requirements, GRC performed a series of quasi-static mechanical tests simulating the pressure, thermal, and external loading conditions that will be experienced by an ASC-E2 heater head assembly. These mechanical tests were collectively referred to as "lateral load tests" since a primary external load lateral to the heater head longitudinal axis was applied in combination with the other loading conditions. The heater head was subjected to the operational pressure, axial mounting force, thermal conditions, and axial and lateral launch vehicle acceleration loadings. To permit reliable prediction of the heater head s structural performance, GRC completed Finite Element Analysis (FEA) computer modeling for the stress, strain, and deformation that will result during launch. The heater head lateral load test directly supported evaluation of the analysis and validation of the design to meet launch requirements. This paper provides an overview of each element within the test and presents assessment of the modeling as well as experimental results of this task.
Lateral Load Testing of the Advanced Stirling Convertor (ASC-E2) Heater Head
NASA Technical Reports Server (NTRS)
Cornell, Peggy A.; Krause, David L.; Davis, Glen; Robbie, Malcolm G.; Gubics, David A.
2010-01-01
Free-piston Stirling convertors are fundamental to the development of NASA s next generation of radioisotope power system, the Advanced Stirling Radioisotope Generator (ASRG). The ASRG will use General Purpose Heat Source (GPHS) modules as the energy source and Advanced Stirling Convertors (ASCs) to convert heat into electrical energy, and is being developed by Lockheed Martin under contract to the Department of Energy. Achieving flight status mandates that the ASCs satisfy design as well as flight requirements to ensure reliable operation during launch. To meet these launch requirements, GRC performed a series of quasi-static mechanical tests simulating the pressure, thermal, and external loading conditions that will be experienced by an ASC E2 heater head assembly. These mechanical tests were collectively referred to as lateral load tests since a primary external load lateral to the heater head longitudinal axis was applied in combination with the other loading conditions. The heater head was subjected to the operational pressure, axial mounting force, thermal conditions, and axial and lateral launch vehicle acceleration loadings. To permit reliable prediction of the heater head s structural performance, GRC completed Finite Element Analysis (FEA) computer modeling for the stress, strain, and deformation that will result during launch. The heater head lateral load test directly supported evaluation of the analysis and validation of the design to meet launch requirements. This paper provides an overview of each element within the test and presents assessment of the modeling as well as experimental results of this task.
14 CFR 33.91 - Engine system and component tests.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., reliability, and durability. (c) Each unpressurized hydraulic fluid tank may not fail or leak when subjected to a maximum operating temperature and an internal pressure of 5 p.s.i., and each pressurized hydraulic fluid tank must meet the requirements of § 33.64. (d) For an engine type certificated for use in...
NASA Technical Reports Server (NTRS)
1979-01-01
Contractor information requirements necessary to support the power extension package project of the space shuttle program are specified for the following categories of data: project management; configuration management; systems engineering and test; manufacturing; reliability, quality assurance and safety; logistics; training; and operations.
QC operator’s nonneutral posture against musculoskeletal disorder’s (MSDs) risks
NASA Astrophysics Data System (ADS)
Kautsar, F.; Gustopo, D.; Achmadi, F.
2018-04-01
Musculoskeletal disorders refer to a gamut of inflammatory and degenerative disorders aggravated largely by the performance of work. It is the major cause of pain, disability, absenteeism and reduced productivity among workers worldwide. Although it is not fatal, MSDs have the potential to develop into serious injuries in the musculoskeletal system if ignored. QC operators work in nonneutral body posture. This cross-sectional study was condusted in order to investigate correlation between risk assessment results of QEC and body posture calculation of mannequin pro. Statistical analysis was condusted using SPSS version 16.0. Validity test, Reliability test and Regression analysis were conducted to compare the risk assessment output of applied method and nonneutral body posture simulation. All of QEC’s indicator classified as valid and reliable. The result of simple regression anlysis are back (0.326<4.32), shoulder/arm (8.489>4.32), wrist/hand (4.86 >4.32) and neck (1.298 <4.32). Result of this study shows that there is an influence between nonneutral body posture of the QC operator during work with risk of musculoskeletal disorders. The potential risk of musculoskeletal disorders is in the shoulder/arm and wrist/hand of the QC operator, whereas the back and neck are not affected.
Operational environments for electrical power wiring on NASA space systems
NASA Technical Reports Server (NTRS)
Stavnes, Mark W.; Hammoud, Ahmad N.; Bercaw, Robert W.
1994-01-01
Electrical wiring systems are used extensively on NASA space systems for power management and distribution, control and command, and data transmission. The reliability of these systems when exposed to the harsh environments of space is very critical to mission success and crew safety. Failures have been reported both on the ground and in flight due to arc tracking in the wiring harnesses, made possible by insulation degradation. This report was written as part of a NASA Office of Safety and Mission Assurance (Code Q) program to identify and characterize wiring systems in terms of their potential use in aerospace vehicles. The goal of the program is to provide the information and guidance needed to develop and qualify reliable, safe, lightweight wiring systems, which are resistant to arc tracking and suitable for use in space power applications. This report identifies the environments in which NASA spacecraft will operate, and determines the specific NASA testing requirements. A summary of related test programs is also given in this report. This data will be valuable to spacecraft designers in determining the best wiring constructions for the various NASA applications.
Ejectors of power plants turbine units efficiency and reliability increasing
NASA Astrophysics Data System (ADS)
Aronson, K. E.; Ryabchikov, A. Yu.; Kuptsov, V. K.; Murmanskii, I. B.; Brodov, Yu. M.; Zhelonkin, N. V.; Khaet, S. I.
2017-11-01
The functioning of steam turbines condensation systems influence on the efficiency and reliability of a power plant a lot. At the same time, the condensation system operating is provided by basic ejectors, which maintain the vacuum level in the condenser. Development of methods of efficiency and reliability increasing for ejector functioning is an actual problem of up-to-date power engineering. In the paper there is presented statistical analysis of ejector breakdowns, revealed during repairing processes, the influence of such damages on the steam turbine operating reliability. It is determined, that 3% of steam turbine equipment breakdowns are the ejector breakdowns. At the same time, about 7% of turbine breakdowns are caused by different ejector malfunctions. Developed and approved design solutions, which can increase the ejector functioning indexes, are presented. Intercoolers are designed in separated cases, so the air-steam mixture can’t move from the high-pressure zones to the low-pressure zones and the maintainability of the apparatuses is increased. By U-type tubes application, the thermal expansion effect of intercooler tubes is compensated and the heat-transfer area is increased. By the applied nozzle fixing construction, it is possible to change the distance between a nozzle and a mixing chamber (nozzle exit position) for operating performance optimization. In operating conditions there are provided experimental researches of more than 30 serial ejectors and also high-efficient 3-staged ejector EPO-3-80, designed by authors. The measurement scheme of the designed ejector includes 21 indicator. The results of experimental tests with different nozzle exit positions of the ejector EPO-3-80 stream devices are presented. The pressure of primary stream (water steam) is optimized. Experimental data are well-approved by the calculation results.
Software reliability through fault-avoidance and fault-tolerance
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.
1993-01-01
Strategies and tools for the testing, risk assessment and risk control of dependable software-based systems were developed. Part of this project consists of studies to enable the transfer of technology to industry, for example the risk management techniques for safety-concious systems. Theoretical investigations of Boolean and Relational Operator (BRO) testing strategy were conducted for condition-based testing. The Basic Graph Generation and Analysis tool (BGG) was extended to fully incorporate several variants of the BRO metric. Single- and multi-phase risk, coverage and time-based models are being developed to provide additional theoretical and empirical basis for estimation of the reliability and availability of large, highly dependable software. A model for software process and risk management was developed. The use of cause-effect graphing for software specification and validation was investigated. Lastly, advanced software fault-tolerance models were studied to provide alternatives and improvements in situations where simple software fault-tolerance strategies break down.
Electromechanical actuation for thrust vector control applications
NASA Technical Reports Server (NTRS)
Roth, Mary Ellen
1990-01-01
The advanced launch system (ALS), is a launch vehicle that is designed to be cost-effective, highly reliable, and operationally efficient with a goal of reducing the cost per pound to orbit. An electromechanical actuation (EMA) system is being developed as an attractive alternative to the hydraulic systems. The controller will integrate 20 kHz resonant link power management and distribution (PMAD) technology and pulse population modulation (PPM) techniques to implement field-oriented vector control (FOVC) of a new advanced induction motor. The driver and the FOVC will be microprocessor controlled. For increased system reliability, a built-in test (BITE) capability will be included. This involves introducing testability into the design of a system such that testing is calibrated and exercised during the design, manufacturing, maintenance, and prelaunch activities. An actuator will be integrated with the motor controller for performance testing of the EMA thrust vector control (TVC) system. The EMA system and work proposed for the future are discussed.
Flow Channel Influence of a Collision-Based Piezoelectric Jetting Dispenser on Jet Performance
Deng, Guiling; Li, Junhui; Duan, Ji’an
2018-01-01
To improve the jet performance of a bi-piezoelectric jet dispenser, mathematical and simulation models were established according to the operating principle. In order to improve the accuracy and reliability of the simulation calculation, a viscosity model of the fluid was fitted to a fifth-order function with shear rate based on rheological test data, and the needle displacement model was fitted to a nine-order function with time based on real-time displacement test data. The results show that jet performance is related to the diameter of the nozzle outlet and the cone angle of the nozzle, and the impacts of the flow channel structure were confirmed. The approach of numerical simulation is confirmed by the testing results of droplet volume. It will provide a reliable simulation platform for mechanical collision-based jet dispensing and a theoretical basis for micro jet valve design and improvement. PMID:29677140
The advantages of the high voltage solar array for electric propulsion
NASA Technical Reports Server (NTRS)
Sater, B. L.
1973-01-01
The high voltage solar array (HVSA) offers improvements in efficiency, weight, and reliability for the electric propulsion power system. The basic HVSA technology involves designing the solar array to deliver power in the form required by the ion thruster. This paper delves into conventional power processes and problems associated with ion thruster operation using SERT II experience for examples. In this light, the advantages of the HVSA concept for electric propulsion are presented. Tests conducted operating the SERT II thruster system in conjunction with HVSA are discussed. Thruster operation was observed to be normal and in some respects improved.
Optimization-Based Management of Energy Systems
2011-05-11
Power [kW] F u e l co n su m p tio n [g a l/h ] 50 kW ~45 kWh 10 Energy Management Framework: Dealing with Uncertainties Test Cases used to exploit...collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE MAY 2011 2. REPORT TYPE 3. DATES COVERED 00-00...served under all operating conditions. ‘Customizable’ power quality and reliability Seamless transition between islanding and off-grid operation
Reliability of constricted double-heterojunction AlGaAs diode lasers
NASA Technical Reports Server (NTRS)
Botez, D.; Connolly, J. C.; Ettenberg, M.; Gilbert, D. B.; Hughes, J. J.
1983-01-01
Constricted double-heterojunction diode lasers have been life tested at 70 C heatsink temperature and 3-4 mW/facet in CW operation. A median life of 7800 h is obtained at 70 C, which extrapolates to 400,000 h median life at room temperature. The extrapolated mean time to failure at room temperature is in excess of 1,000,000 h. Single-longitudinal-mode CW operation is maintained after 10,000 h of accelerated aging at 70 C.
A new bipolar Qtrim power supply system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mi, C.; Bruno, D.; Drozd, J.
2015-05-03
This year marks the 15th run of RHIC (Relativistic Heavy Ion Collider) operations. The reliability of superconducting magnet power supplies is one of the essential factors in the entire accelerator complex. Besides maintaining existing power supplies and their associated equipment, newly designed systems are also required based on the physicist’s latest requirements. A bipolar power supply was required for this year’s main quadruple trim power supply. This paper will explain the design, prototype, testing, installation and operation of this recently installed power supply system.
Gligorijevic, Jovan; Gajic, Dragoljub; Brkovic, Aleksandar; Savic-Gajic, Ivana; Georgieva, Olga; Di Gennaro, Stefano
2016-03-01
The packaging materials industry has already recognized the importance of Total Productive Maintenance as a system of proactive techniques for improving equipment reliability. Bearing faults, which often occur gradually, represent one of the foremost causes of failures in the industry. Therefore, detection of their faults in an early stage is quite important to assure reliable and efficient operation. We present a new automated technique for early fault detection and diagnosis in rolling-element bearings based on vibration signal analysis. Following the wavelet decomposition of vibration signals into a few sub-bands of interest, the standard deviation of obtained wavelet coefficients is extracted as a representative feature. Then, the feature space dimension is optimally reduced to two using scatter matrices. In the reduced two-dimensional feature space the fault detection and diagnosis is carried out by quadratic classifiers. Accuracy of the technique has been tested on four classes of the recorded vibrations signals, i.e., normal, with the fault of inner race, outer race, and ball operation. The overall accuracy of 98.9% has been achieved. The new technique can be used to support maintenance decision-making processes and, thus, to increase reliability and efficiency in the industry by preventing unexpected faulty operation of bearings.
Gligorijevic, Jovan; Gajic, Dragoljub; Brkovic, Aleksandar; Savic-Gajic, Ivana; Georgieva, Olga; Di Gennaro, Stefano
2016-01-01
The packaging materials industry has already recognized the importance of Total Productive Maintenance as a system of proactive techniques for improving equipment reliability. Bearing faults, which often occur gradually, represent one of the foremost causes of failures in the industry. Therefore, detection of their faults in an early stage is quite important to assure reliable and efficient operation. We present a new automated technique for early fault detection and diagnosis in rolling-element bearings based on vibration signal analysis. Following the wavelet decomposition of vibration signals into a few sub-bands of interest, the standard deviation of obtained wavelet coefficients is extracted as a representative feature. Then, the feature space dimension is optimally reduced to two using scatter matrices. In the reduced two-dimensional feature space the fault detection and diagnosis is carried out by quadratic classifiers. Accuracy of the technique has been tested on four classes of the recorded vibrations signals, i.e., normal, with the fault of inner race, outer race, and ball operation. The overall accuracy of 98.9% has been achieved. The new technique can be used to support maintenance decision-making processes and, thus, to increase reliability and efficiency in the industry by preventing unexpected faulty operation of bearings. PMID:26938541
Sevdalis, Nick; Undre, Shabnam; Henry, Janet; Sydney, Elaine; Koutantji, Mary; Darzi, Ara; Vincent, Charles A
2009-09-01
The recent emergence of the Systems Approach to the safety and quality of surgical care has triggered individual and team skills training modules for surgeons and anaesthetists and relevant observational assessment tools have been developed. To develop an observational tool that captures operating room (OR) nurses' technical skill and can be used for assessment and training. The Imperial College Assessment of Technical Skills for Nurses (ICATS-N) assesses (i) gowning and gloving, (ii) setting up instrumentation, (iii) draping, and (iv) maintaining sterility. Three to five observable behaviours have been identified for each skill and are rated on 1-6 scales. Feasibility and aspects of reliability and validity were assessed in 20 simulation-based crisis management training modules for trainee nurses and doctors, carried out in a Simulated Operating Room. The tool was feasible to use in the context of simulation-based training. Satisfactory reliability (Cronbach alpha) was obtained across trainers' and trainees' scores (analysed jointly and separately). Moreover, trainer nurse's ratings of the four skills correlated positively, thus indicating adequate content validity. Trainer's and trainees' ratings did not correlate. Assessment of OR nurses' technical skill is becoming a training priority. The present evidence suggests that the ICATS-N could be considered for use as an assessment/training tool for junior OR nurses.
NASA Technical Reports Server (NTRS)
1994-01-01
This manual presents a series of recommended techniques that can increase overall operational effectiveness of both flight and ground based NASA systems. It provides a set of tools that minimizes risk associated with: (1) restoring failed functions (both ground and flight based); (2) conducting complex and highly visible maintenance operations; and (3) sustaining a technical capability to support the NASA mission using aging equipment or facilities. It considers (1) program management - key elements of an effective maintainability effort; (2) design and development - techniques that have benefited previous programs; (3) analysis and test - quantitative and qualitative analysis processes and testing techniques; and (4) operations and operational design techniques that address NASA field experience. This document is a valuable resource for continuous improvement ideas in executing the systems development process in accordance with the NASA 'better, faster, smaller, and cheaper' goal without compromising safety.
Fernandes, Tânia; Araújo, Susana; Sucena, Ana; Reis, Alexandra; Castro, São Luís
2017-02-01
Reading is a central cognitive domain, but little research has been devoted to standardized tests for adults. We, thus, examined the psychometric properties of the 1-min version of Teste de Idade de Leitura (Reading Age Test; 1-min TIL), the Portuguese version of Lobrot L3 test, in three experiments with college students: typical readers in Experiment 1A and B, dyslexic readers and chronological age controls in Experiment 2. In Experiment 1A, test-retest reliability and convergent validity were evaluated in 185 students. Reliability was >.70, and phonological decoding underpinned 1-min TIL. In Experiment 1B, internal consistency was assessed by presenting two 45-s versions of the test to 19 students, and performance in these versions was significantly associated (r = .78). In Experiment 2, construct validity, criterion validity and clinical utility of 1-min TIL were investigated. A multiple regression analysis corroborated construct validity; both phonological decoding and listening comprehension were reliable predictors of 1-min TIL scores. Logistic regression and receiver operating characteristics analyses revealed the high accuracy of this test in distinguishing dyslexic from typical readers. Therefore, the 1-min TIL, which assesses reading comprehension and potential reading difficulties in college students, has the necessary psychometric properties to become a useful screening instrument in neuropsychological assessment and research. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Validity of the Talk Test for exercise prescription after myocardial revascularization.
Zanettini, Renzo; Centeleghe, Paola; Franzelli, Cristina; Mori, Ileana; Benna, Stefania; Penati, Chiara; Sorlini, Nadia
2013-04-01
For exercise prescription, rating of perceived exertion is the subjective tool most frequently used in addition to methods based on percentage of peak exercise variables. The aim of this study was the validation of a subjective method widely called the Talk Test (TT) for optimization of training intensity in patients with recent myocardial revascularization. Fifty patients with recent myocardial revascularization (17 by coronary artery bypass grafting and 33 by percutaneous coronary intervention) were enrolled in a cardiac rehabilitation programme. Each patient underwent three repetitions of the TT during three different exercise sessions to evaluate the within-patient and between-operators reliability in assessing the workload (WL) at TT thresholds. These parameters were then compared with the data of a final cardiopulmonary exercise testing, and the WL range between the individual aerobic threshold (AeT) and anaerobic threshold (AnT) was considered as the optimal training zone. The within-patient and between-operators reliability in assessing TT thresholds were satisfactory. No significant differences were found between patients' and physiotherapists' evaluations of WL at different TT thresholds. WL at Last TT+ was between AeT and AnT in 88% of patients and slightly
Distribution System Reliability Analysis for Smart Grid Applications
NASA Astrophysics Data System (ADS)
Aljohani, Tawfiq Masad
Reliability of power systems is a key aspect in modern power system planning, design, and operation. The ascendance of the smart grid concept has provided high hopes of developing an intelligent network that is capable of being a self-healing grid, offering the ability to overcome the interruption problems that face the utility and cost it tens of millions in repair and loss. To address its reliability concerns, the power utilities and interested parties have spent extensive amount of time and effort to analyze and study the reliability of the generation and transmission sectors of the power grid. Only recently has attention shifted to be focused on improving the reliability of the distribution network, the connection joint between the power providers and the consumers where most of the electricity problems occur. In this work, we will examine the effect of the smart grid applications in improving the reliability of the power distribution networks. The test system used in conducting this thesis is the IEEE 34 node test feeder, released in 2003 by the Distribution System Analysis Subcommittee of the IEEE Power Engineering Society. The objective is to analyze the feeder for the optimal placement of the automatic switching devices and quantify their proper installation based on the performance of the distribution system. The measures will be the changes in the reliability system indices including SAIDI, SAIFI, and EUE. The goal is to design and simulate the effect of the installation of the Distributed Generators (DGs) on the utility's distribution system and measure the potential improvement of its reliability. The software used in this work is DISREL, which is intelligent power distribution software that is developed by General Reliability Co.
Composite Overwrapped Pressure Vessels (COPV) Stress Rupture Test: Part 2. Part 2
NASA Technical Reports Server (NTRS)
Russell, Richard; Flynn, Howard; Forth, Scott; Greene, Nathanael; Kezirian, Michael; Varanauski, Don; Leifeste, Mark; Yoder, Tommy; Woodworth, Warren
2010-01-01
One of the major concerns for the aging Space Shuttle fleet is the stress rupture life of composite overwrapped pressure vessels (COPVs). Stress rupture life of a COPY has been defined as the minimum time during which the composite maintains structural integrity considering the combined effects of stress levels and time. To assist in the evaluation of the aging COPVs in the Orbiter fleet an analytical reliability model was developed. The actual data used to construct this model was from testing of COPVs constructed of similar, but not exactly same materials and pressure cycles as used on Orbiter vessels. Since no actual Orbiter COPV stress rupture data exists the Space Shuttle Program decided to run a stress rupture test to compare to model predictions. Due to availability of spares, the testing was unfortunately limited to one 40" vessel. The stress rupture test was performed at maximum operating pressure at an elevated temperature to accelerate aging. The test was performed in two phases. The first phase, 130 F, a moderately accelerated test designed to achieve the midpoint of the model predicted point reliability. A more aggressive second phase, performed at 160 F, was designed to determine if the test article will exceed the 95% confidence interval ofthe model. In phase 3, the vessel pressure was increased to above maximum operating pressure while maintaining the phase 2 temperature. After reaching enough effectives hours to reach the 99.99% confidence level of the model phase 4 testing began when the temperature was increased to greater than 170 F. The vessel was maintained at phase 4 conditions until it failed after over 3 million effect hours. This paper will discuss the results of this test, it's implications and possible follow-on testing.
Reliability and availability analysis of a 10 kW@20 K helium refrigerator
NASA Astrophysics Data System (ADS)
Li, J.; Xiong, L. Y.; Liu, L. Q.; Wang, H. R.; Wang, B. M.
2017-02-01
A 10 kW@20 K helium refrigerator has been established in the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. To evaluate and improve this refrigerator’s reliability and availability, a reliability and availability analysis is performed. According to the mission profile of this refrigerator, a functional analysis is performed. The failure data of the refrigerator components are collected and failure rate distributions are fitted by software Weibull++ V10.0. A Failure Modes, Effects & Criticality Analysis (FMECA) is performed and the critical components with higher risks are pointed out. Software BlockSim V9.0 is used to calculate the reliability and the availability of this refrigerator. The result indicates that compressors, turbine and vacuum pump are the critical components and the key units of this refrigerator. The mitigation actions with respect to design, testing, maintenance and operation are proposed to decrease those major and medium risks.
Does the Modified Gartland Classification Clarify Decision Making?
Leung, Sophia; Paryavi, Ebrahim; Herman, Martin J; Sponseller, Paul D; Abzug, Joshua M
2018-01-01
The modified Gartland classification system for pediatric supracondylar fractures is often utilized as a communication tool to aid in determining whether or not a fracture warrants operative intervention. This study sought to determine the interobserver and intraobserver reliability of the Gartland classification system, as well as to determine whether there was agreement that a fracture warranted operative intervention regardless of the classification system. A total of 200 anteroposterior and lateral radiographs of pediatric supracondylar humerus fractures were retrospectively reviewed by 3 fellowship-trained pediatric orthopaedic surgeons and 2 orthopaedic residents and then classified as type I, IIa, IIb, or III. The surgeons then recorded whether they would treat the fracture nonoperatively or operatively. The κ coefficients were calculated to determine interobserver and intraobserver reliability. Overall, the Wilkins-modified Gartland classification has low-moderate interobserver reliability (κ=0.475) and high intraobserver reliability (κ=0.777). A low interobserver reliability was found when differentiating between type IIa and IIb (κ=0.240) among attendings. There was moderate-high interobserver reliability for the decision to operate (κ=0.691) and high intraobserver reliability (κ=0.760). Decreased interobserver reliability was present for decision to operate among residents. For fractures classified as type I, the decision to operate was made 3% of the time and 27% for type IIa. The decision was made to operate 99% of the time for type IIb and 100% for type III. There is almost full agreement for the nonoperative treatment of Type I fractures and operative treatment for type III fractures. There is agreement that type IIb fractures should be treated operatively and that the majority of type IIa fractures should be treated nonoperatively. However, the interobserver reliability for differentiating between type IIa and IIb fractures is low. Our results validate the Gartland classfication system as a method to help direct treatment of pediatric supracondylar humerus fractures, although the modification of the system, IIa versus IIb, seems to have limited reliability and utility. Terminology based on decision to treat may lead to a more clinically useful classification system in the evaluation and treatment of pediatric supracondylar humerus fractures. Level III-diagnostic studies.
Demonstration of Essential Reliability Services by a 300-MW Solar Photovoltaic Power Plant
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loutan, Clyde; Klauer, Peter; Chowdhury, Sirajul
The California Independent System Operator (CAISO), First Solar, and the National Renewable Energy Laboratory (NREL) conducted a demonstration project on a large utility-scale photovoltaic (PV) power plant in California to test its ability to provide essential ancillary services to the electric grid. With increasing shares of solar- and wind-generated energy on the electric grid, traditional generation resources equipped with automatic governor control (AGC) and automatic voltage regulation controls -- specifically, fossil thermal -- are being displaced. The deployment of utility-scale, grid-friendly PV power plants that incorporate advanced capabilities to support grid stability and reliability is essential for the large-scale integrationmore » of PV generation into the electric power grid, among other technical requirements. A typical PV power plant consists of multiple power electronic inverters and can contribute to grid stability and reliability through sophisticated 'grid-friendly' controls. In this way, PV power plants can be used to mitigate the impact of variability on the grid, a role typically reserved for conventional generators. In August 2016, testing was completed on First Solar's 300-MW PV power plant, and a large amount of test data was produced and analyzed that demonstrates the ability of PV power plants to use grid-friendly controls to provide essential reliability services. These data showed how the development of advanced power controls can enable PV to become a provider of a wide range of grid services, including spinning reserves, load following, voltage support, ramping, frequency response, variability smoothing, and frequency regulation to power quality. Specifically, the tests conducted included various forms of active power control such as AGC and frequency regulation; droop response; and reactive power, voltage, and power factor controls. This project demonstrated that advanced power electronics and solar generation can be controlled to contribute to system-wide reliability. It was shown that the First Solar plant can provide essential reliability services related to different forms of active and reactive power controls, including plant participation in AGC, primary frequency control, ramp rate control, and voltage regulation. For AGC participation in particular, by comparing the PV plant testing results to the typical performance of individual conventional technologies, we showed that regulation accuracy by the PV plant is 24-30 points better than fast gas turbine technologies. The plant's ability to provide volt-ampere reactive control during periods of extremely low power generation was demonstrated as well. The project team developed a pioneering demonstration concept and test plan to show how various types of active and reactive power controls can leverage PV generation's value from being a simple variable energy resource to a resource that provides a wide range of ancillary services. With this project's approach to a holistic demonstration on an actual, large, utility-scale, operational PV power plant and dissemination of the obtained results, the team sought to close some gaps in perspectives that exist among various stakeholders in California and nationwide by providing real test data.« less
NASA Technical Reports Server (NTRS)
Gangwani, S. T.
1985-01-01
A reliable rotor aeroelastic analysis operational that correctly predicts the vibration levels for a helicopter is utilized to test various unsteady aerodynamics models with the objective of improving the correlation between test and theory. This analysis called Rotor Aeroelastic Vibration (RAVIB) computer program is based on a frequency domain forced response analysis which utilizes the transfer matrix techniques to model helicopter/rotor dynamic systems of varying degrees of complexity. The results for the AH-1G helicopter rotor were compared with the flight test data during high speed operation and they indicated a reasonably good correlation for the beamwise and chordwise blade bending moments, but for torsional moments the correlation was poor. As a result, a new aerodynamics model based on unstalled synthesized data derived from the large amplitude oscillating airfoil experiments was developed and tested.
NASA Technical Reports Server (NTRS)
Schifer, Nicholas A.; Oriti, Salvatore M.
2013-01-01
The NASA Glenn Research Center (GRC) has been testing 100 We class, free-piston Stirling convertors for potential use in Stirling Radioisotope Power Systems (RPS) for space science and exploration missions. Free-piston Stirling convertors are capable of achieving a 38% conversion efficiency, making Stirling attractive for meeting future power system needs in light of the shrinking U.S. plutonium fuel supply. Convertors currently on test include four Stirling Technology Demonstration Convertors (TDCs), manufactured by the Stirling Technology Company (STC), and six Advanced Stirling Convertors (ASCs), manufactured by Sunpower, Inc. Total hours of operation is greater than 514,000 hours (59 years). Several tests have been initiated to demonstrate the functionality of Stirling convertors for space applications, including: in-air extended operation, thermal vacuum extended operation. Other tests have also been conducted to characterize Stirling performance in anticipated mission scenarios. Data collected during testing has been used to support life and reliability estimates, drive design changes and improve quality, and plan for expected mission scenarios. This paper will provide a summary of convertors tested at NASA GRC and discuss lessons learned through extended testing.
Promoting Robust Design of Diode Lasers for Space: A National Initiative
NASA Technical Reports Server (NTRS)
Tratt, David M.; Amzajerdian, Farzin; Kashem, Nasir B.; Shapiro, Andrew A.; Mense, Allan T.
2007-01-01
The Diode-laser Array Working Group (DAWG) is a national-level consumer/provider forum for discussion of engineering and manufacturing issues which influence the reliability and survivability of high-power broad-area laser diode devices in space, with an emphasis on laser diode arrays (LDAs) for optical pumping of solid-state laser media. The goals of the group are to formulate and validate standardized test and qualification protocols, operational control recommendations, and consensus manufacturing and certification standards. The group is using reliability and lifetime data collected by laser diode manufacturers and the user community to develop a set of standardized guidelines for specifying and qualifying laser diodes for long-duration operation in space, the ultimate goal being to promote an informed U.S. Government investment and procurement strategy for assuring the availability and durability of space-qualified LDAs. The group is also working to establish effective implementation of statistical design techniques at the supplier design, development, and manufacturing levels to help reduce product performance variability and improve product reliability for diodes employed in space applications
Highly reliable high speed 1.1μm-InGaAs/GaAsP-VCSELs
NASA Astrophysics Data System (ADS)
Hatakeyama, H.; Anan, T.; Akagawa, T.; Fukatsu, K.; Suzuki, N.; Tokutome, K.; Tsuji, M.
2009-02-01
In this paper, we describe high temperature operation of high speed 1.1μm-range oxide-confined vertical-cavity surfaceemitting lasers (VCSELs) for optical interconnection applications. For achieving high speed of over 25 Gbit/s under a high temperature, we applied InGaAs/GaAsP strain-compensated multiple quantum wells (SC-MQWs) as the active layer. The developed device showed 25 Gbit/s error-free operation at 100°C. We also examined reliability of the VCSELs via accelerated life tests. The result showed extremely long MTTF lifetime of about 10 thousand hours under an ambient temperature of 150°C and a bias current of about 19 kA/cm2, a reliability that either equals or surpasses that of conventional 850-nm VCSELs with 10 Gbit/s. Moreover, we revealed a typical failure mode of the device; the result of analysis indicated that the failure was caused by <110> dark line defects (DLDs) generated in the n-DBR layers under the current aperture area.
Campagna, Giuseppe; Zampetti, Simona; Gallozzi, Alessia; Giansanti, Sara; Chiesa, Claudio; Pacifico, Lucia; Buzzetti, Raffaella
2016-01-01
In a previous study, we found that wrist circumference, in particular its bone component, was associated with insulin resistance in a population of overweight/obese children. The aim of the present study was to evaluate the intra- and inter-operator variability in wrist circumference measurement in a population of obese children and adolescents. One hundred and two (54 male and 48 female) obese children and adolescents were consecutively enrolled. In all subjects wrist circumferences were measured by two different operators two times to assess intra- and inter-operator variability. Statistical analysis was performed using SAS v.9.4 and JMP v.12. Measurements of wrist circumference showed excellent inter-operator reliability with Intra class Correlation Coefficients (ICC) of 0.96 and ICC of 0.97 for the first and the second measurement, respectively. The intra-operator reliability was, also, very strong with a Concordance Correlation Coefficient (CCC) of 0.98 for both operators. The high reproducibility demonstrated in our results suggests that wrist circumference measurement, being safe, non-invasive and repeatable can be easily used in out-patient settings to identify youths with increased risk of insulin-resistance. This can avoid testing the entire population of overweight/obese children for insulin resistance parameters. PMID:27294398
Reliable semiclassical computations in QCD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dine, Michael; Department of Physics, Stanford University Stanford, California 94305-4060; Festuccia, Guido
We revisit the question of whether or not one can perform reliable semiclassical QCD computations at zero temperature. We study correlation functions with no perturbative contributions, and organize the problem by means of the operator product expansion, establishing a precise criterion for the validity of a semiclassical calculation. For N{sub f}>N, a systematic computation is possible; for N{sub f}
Zhou, Yong; Mu, Haiying; Jiang, Jianjun; Zhang, Li
2012-01-01
Currently, there is a trend in nuclear power plants (NPPs) toward introducing digital and computer technologies into main control rooms (MCRs). Safe generation of electric power in NPPs requires reliable performance of cognitive tasks such as fault detection, diagnosis, and response planning. The digitalization of MCRs has dramatically changed the whole operating environment, and the ways operators interact with the plant systems. If the design and implementation of the digital technology is incompatible with operators' cognitive characteristics, it may have negative effects on operators' cognitive reliability. Firstly, on the basis of three essential prerequisites for successful cognitive tasks, a causal model is constructed to reveal the typical human performance issues arising from digitalization. The cognitive mechanisms which they impact cognitive reliability are analyzed in detail. Then, Bayesian inference is used to quantify and prioritize the influences of these factors. It suggests that interface management and unbalanced workload distribution have more significant impacts on operators' cognitive reliability.
Reliability enhancement through optimal burn-in
NASA Astrophysics Data System (ADS)
Kuo, W.
1984-06-01
A numerical reliability and cost model is defined for production line burn-in tests of electronic components. The necessity of burn-in is governed by upper and lower bounds: burn-in is mandatory for operation-critical or nonreparable component; no burn-in is needed when failure effects are insignificant or easily repairable. The model considers electronic systems in terms of a series of components connected by a single black box. The infant mortality rate is described with a Weibull distribution. Performance reaches a steady state after burn-in, and the cost of burn-in is a linear function for each component. A minimum cost is calculated among the costs and total time of burn-in, shop repair, and field repair, with attention given to possible losses in future sales from inadequate burn-in testing.
Reliability of Radioisotope Stirling Convertor Linear Alternator
NASA Technical Reports Server (NTRS)
Shah, Ashwin; Korovaichuk, Igor; Geng, Steven M.; Schreiber, Jeffrey G.
2006-01-01
Onboard radioisotope power systems being developed and planned for NASA s deep-space missions would require reliable design lifetimes of up to 14 years. Critical components and materials of Stirling convertors have been undergoing extensive testing and evaluation in support of a reliable performance for the specified life span. Of significant importance to the successful development of the Stirling convertor is the design of a lightweight and highly efficient linear alternator. Alternator performance could vary due to small deviations in the permanent magnet properties, operating temperature, and component geometries. Durability prediction and reliability of the alternator may be affected by these deviations from nominal design conditions. Therefore, it is important to evaluate the effect of these uncertainties in predicting the reliability of the linear alternator performance. This paper presents a study in which a reliability-based methodology is used to assess alternator performance. The response surface characterizing the induced open-circuit voltage performance is constructed using 3-D finite element magnetic analysis. Fast probability integration method is used to determine the probability of the desired performance and its sensitivity to the alternator design parameters.
NASA Astrophysics Data System (ADS)
Gurov, V. V.
2017-01-01
Software tools for educational purposes, such as e-lessons, computer-based testing system, from the point of view of reliability, have a number of features. The main ones among them are the need to ensure a sufficiently high probability of their faultless operation for a specified time, as well as the impossibility of their rapid recovery by the way of replacing it with a similar running program during the classes. The article considers the peculiarities of reliability evaluation of programs in contrast to assessments of hardware reliability. The basic requirements to reliability of software used for carrying out practical and laboratory classes in the form of computer-based training programs are given. The essential requirements applicable to the reliability of software used for conducting the practical and laboratory studies in the form of computer-based teaching programs are also described. The mathematical tool based on Markov chains, which allows to determine the degree of debugging of the training program for use in the educational process by means of applying the graph of the software modules interaction, is presented.
Chen, Xiao; Lu, Bin; Yan, Chao-Gan
2018-01-01
Concerns regarding reproducibility of resting-state functional magnetic resonance imaging (R-fMRI) findings have been raised. Little is known about how to operationally define R-fMRI reproducibility and to what extent it is affected by multiple comparison correction strategies and sample size. We comprehensively assessed two aspects of reproducibility, test-retest reliability and replicability, on widely used R-fMRI metrics in both between-subject contrasts of sex differences and within-subject comparisons of eyes-open and eyes-closed (EOEC) conditions. We noted permutation test with Threshold-Free Cluster Enhancement (TFCE), a strict multiple comparison correction strategy, reached the best balance between family-wise error rate (under 5%) and test-retest reliability/replicability (e.g., 0.68 for test-retest reliability and 0.25 for replicability of amplitude of low-frequency fluctuations (ALFF) for between-subject sex differences, 0.49 for replicability of ALFF for within-subject EOEC differences). Although R-fMRI indices attained moderate reliabilities, they replicated poorly in distinct datasets (replicability < 0.3 for between-subject sex differences, < 0.5 for within-subject EOEC differences). By randomly drawing different sample sizes from a single site, we found reliability, sensitivity and positive predictive value (PPV) rose as sample size increased. Small sample sizes (e.g., < 80 [40 per group]) not only minimized power (sensitivity < 2%), but also decreased the likelihood that significant results reflect "true" effects (PPV < 0.26) in sex differences. Our findings have implications for how to select multiple comparison correction strategies and highlight the importance of sufficiently large sample sizes in R-fMRI studies to enhance reproducibility. Hum Brain Mapp 39:300-318, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Mitchell, Katy; Graff, Megan; Hedt, Corbin; Simmons, James
2016-08-01
Purpose/hypothesis: This study was designed to investigate the test-retest reliability, concurrent validity, and the standard error of measurement (SEm) of a pulse rate assessment application (Azumio®'s Instant Heart Rate) on both Android® and iOS® (iphone operating system) smartphones as compared to a FT7 Polar® Heart Rate monitor. Number of subjects: 111. Resting (sitting) pulse rate was assessed twice and then the participants were asked to complete a 1-min standing step test and then immediately re-assessed. The smartphone assessors were blinded to their measurements. Test-retest reliability (intraclass correlation coefficient [ICC 2,1] and 95% confidence interval) for the three tools at rest (time 1/time 2): iOS® (0.76 [0.67-0.83]); Polar® (0.84 [0.78-0.89]); and Android® (0.82 [0.75-0.88]). Concurrent validity at rest time 2 (ICC 2,1) with the Polar® device: IOS® (0.92 [0.88-0.94]) and Android® (0.95 [0.92-0.96]). Concurrent validity post-exercise (time 3) (ICC) with the Polar® device: iOS® (0.90 [0.86-0.93]) and Android® (0.94 [0.91-0.96]). The SEm values for the three devices at rest: iOS® (5.77 beats per minute [BPM]), Polar® (4.56 BPM) and Android® (4.96 BPM). The Android®, iOS®, and Polar® devices showed acceptable test-retest reliability at rest and post-exercise. Both the smartphone platforms demonstrated concurrent validity with the Polar® at rest and post-exercise. The Azumio® Instant Heart Rate application when used by either platform appears to be a reliable and valid tool to assess pulse rate in healthy individuals.
Summary of Stirling Convertor Testing at NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey G.
2006-01-01
The NASA Glenn Research Center (GRC) has been testing free-piston Stirling convertors for potential use in radioisotope power systems. These convertors tend to be in the 35 to 80 W electric power output range. Tests at GRC have accumulated over 80,000 hr of operation. Test articles have been received from Infinia Corporation of Kennewick, Washington and from Sunpower of Athens, Ohio. Infinia designed and built the developmental Stirling Technology Demonstration Convertors (TDC) in addition to the more advanced Test Bed and Engineering Unit convertors. GRC has eight of the TDC's under test including two that operate in a thermal vacuum environment. Sunpower designed and developed the EE-35 and the Advanced Stirling Convertor (ASC). GRC has six of the EE- 35 s and is preparing for testing multiple ASC s. Free-piston Stirling convertors for radioisotope power systems make use of non-contacting operation that eliminates wear and is suited for long-term operation. Space missions with radioisotope power systems are often considered that extend from three to 14 years. One of the key capabilities of the GRC test facility is the ability to support continuous, unattended operation. Hardware, software, and procedures for preparing the test articles were developed to support these tests. These included the processing of the convertors for minimizing the contaminants in the working fluid, developing a helium charging system for filling and for gas sample analysis, and the development of new control software and a high-speed protection circuit to insure safe, round-the-clock operation. Performance data of Stirling convertors over time is required to demonstrate that a radioisotope power system is capable of providing reliable power for multi-year missions. This paper will discuss the status of Stirling convertor testing at GRC.
Summary of Stirling Convertor Testing at GRC
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey G.
2006-01-01
The NASA Glenn Research Center (GRC) has been testing free-piston Stirling convertors for potential use in radioisotope power systems. These convertors tend to be in the 35 to 80 watt electric power output range. Tests at GRC have accumulated over 80,000 hours of operation. Test articles have been received from Infinia Corporation of Kennewick, WA and from Sunpower of Athens, OH. Infinia designed and built the developmental Stirling Technology Demonstration Convertors (TDC) in addition to the more advanced Test Bed and Engineering Unit convertors. GRC has eight of the TDC's under test including two that operate in a thermal vacuum environment. Sunpower designed and developed the EE- 35 and the Advanced Stirling Convertor (ASC). GRC has six of the EE-35's and is preparing for testing multiple ASC's. Free-piston Stirling convertors for radioisotope power systems make use of non-contacting operation that eliminates wear and is suited for longterm operation. Space missions with radioisotope power systems are often considered that extend from three to 14 years. One of the key capabilities of the GRC test facility is the ability to support continuous, unattended operation. Hardware, software, and procedures for preparing the test articles were developed to support these tests. These included the processing of the convertors for minimizing the contaminants in the working fluid, developing a helium charging system for filling and for gas sample analysis, and the development of new control software and a high-speed protection circuit to insure safe, round-the-clock operation. Performance data of Stirling convertors over time is required to demonstrate that a radioisotope power system is capable of providing reliable power for multi-year missions. This paper will discuss the status of Stirling convertor testing at GRC.
Molding compound trends in a denser packaging world: Qualification tests and reliability concerns
NASA Astrophysics Data System (ADS)
Nguyen, L. T.; Lo, R. H. Y.; Chen, A. S.; Belani, J. G.
1993-12-01
Molding compound development has traditionally been driven by the memory market, then subsequent applications filter down to other IC technologies such as logic, analog, and ASIC. However, this strategy has changed lately with the introduction of thin packages such as PQFP & TSOP. Rather than targeting a compound for a family of IC such as DRAM or SRAM, compound development efforts are now focused at specific classes of packages. The configurations of these thin packages impose new functional requirements that need to be revisited to provide the optimized combination of properties. The evolution of qualification tests mirrors the advances in epoxy and compounding technologies. From the first standard novolac-based epoxies of the 1970s to the latest 3(sup rd)-generation ultra-low stress materials, longer test times at increasingly harsher environments were achieved. This paper benchmarks the current reliability tests used by the electronic industry, examines those tests that affect and are affected by the molding compounds, discusses the relevance of accelerated testing, and addresses the major reliability issues facing current molding compound development efforts. Six compound-related reliability concerns were selected: moldability, package stresses, package cracking, halogen-induced intermetallic growth at bond pads, moisture-induced corrosion, and interfacial delamination. Causes of each failure type are surveyed and remedies are recommended. Accelerated tests are designed to apply to a limited quantity of devices, bias, or environmental conditions larger than usual ratings, to intensify failure mechanisms that would occur under normal operating conditions. The observed behavior is then extrapolated from the lot to the entire population. Emphasis is on compressing the time necessary to obtain reliability data. This approach has two main drawbacks. With increasingly complex devices, even accelerated tests are expensive. And with new technologies, it becomes difficult to ascertain that the applied stress 1) induces the failure phenomenon linked with usual field conditions, and 2) does not create any new ones. Technology evolution and reliability testing are interdependent. Devices get larger with increasingly smaller features and more complex geometries. Molding compounds have evolved considerably over the past decade to provide ultra-low stress levels and moldability for thin packages.
NASA Technical Reports Server (NTRS)
Gernand, Jeffrey L.; Gillespie, Amanda M.; Monaghan, Mark W.; Cummings, Nicholas H.
2010-01-01
Success of the Constellation Program's lunar architecture requires successfully launching two vehicles, Ares I/Orion and Ares V/Altair, in a very limited time period. The reliability and maintainability of flight vehicles and ground systems must deliver a high probability of successfully launching the second vehicle in order to avoid wasting the on-orbit asset launched by the first vehicle. The Ground Operations Project determined which ground subsystems had the potential to affect the probability of the second launch and allocated quantitative availability requirements to these subsystems. The Ground Operations Project also developed a methodology to estimate subsystem reliability, availability and maintainability to ensure that ground subsystems complied with allocated launch availability and maintainability requirements. The verification analysis developed quantitative estimates of subsystem availability based on design documentation; testing results, and other information. Where appropriate, actual performance history was used for legacy subsystems or comparative components that will support Constellation. The results of the verification analysis will be used to verify compliance with requirements and to highlight design or performance shortcomings for further decision-making. This case study will discuss the subsystem requirements allocation process, describe the ground systems methodology for completing quantitative reliability, availability and maintainability analysis, and present findings and observation based on analysis leading to the Ground Systems Preliminary Design Review milestone.
Randall Simpson, Janis; Gumbley, Jillian; Whyte, Kylie; Lac, Jane; Morra, Crystal; Rysdale, Lee; Turfryer, Mary; McGibbon, Kim; Beyers, Joanne; Keller, Heather
2015-09-01
Nutrition is vital for optimal growth and development of young children. Nutrition risk screening can facilitate early intervention when followed by nutritional assessment and treatment. NutriSTEP (Nutrition Screening Tool for Every Preschooler) is a valid and reliable nutrition risk screening questionnaire for preschoolers (aged 3-5 years). A need was identified for a similar questionnaire for toddlers (aged 18-35 months). The purpose was to develop a reliable and valid Toddler NutriSTEP. Toddler NutriSTEP was developed in 4 phases. Content and face validity were determined with a literature review, parent focus groups (n = 6; 48 participants), and experts (n = 13) (phase A). A draft questionnaire was refined with key intercept interviews of 107 parents/caregivers (phase B). Test-retest reliability (phase C), based on intra-class correlations (ICC), Kappa (κ) statistics, and Wilcoxon tests was assessed with 133 parents/caregivers. Criterion validity (phase D) was assessed using Receiver Operating Characteristic (ROC) curves by comparing scores on the Toddler NutriSTEP to a comprehensive nutritional assessment of 200 toddlers with a registered dietitian (RD). The Toddler NutriSTEP was reliable between 2 administrations (ICC = 0.951, F = 20.53, p < 0.001); most questions had moderate (κ ≥ 0.6) or excellent (κ ≥ 0.8) agreement. Scores on the RD nutrition risk rating and the Toddler NutriSTEP were correlated (r = 0.67, p < 0.000). The area under the ROC curve for moderate and high RD risk ratings were 84.6% and 82.7%, respectively. Cut-points of ≥21 (sensitivity 86%; specificity 61%) (moderate risk) and ≥26 (sensitivity 95%; specificity 63%) (high risk) were determined. The Toddler NutriSTEP questionnaire is both reliable and valid for screening for nutritional risk in toddlers.
Mkentane, K; Van Wyk, J C; Sishi, N; Gumedze, F; Ngoepe, M; Davids, L M; Khumalo, N P
2017-01-01
Curly hair is reported to contain higher lipid content than straight hair, which may influence incorporation of lipid soluble drugs. The use of race to describe hair curl variation (Asian, Caucasian and African) is unscientific yet common in medical literature (including reports of drug levels in hair). This study investigated the reliability of a geometric classification of hair (based on 3 measurements: the curve diameter, curl index and number of waves). After ethical approval and informed consent, proximal virgin (6cm) hair sampled from the vertex of scalp in 48 healthy volunteers were evaluated. Three raters each scored hairs from 48 volunteers at two occasions each for the 8 and 6-group classifications. One rater applied the 6-group classification to 80 additional volunteers in order to further confirm the reliability of this system. The Kappa statistic was used to assess intra and inter rater agreement. Each rater classified 480 hairs on each occasion. No rater classified any volunteer's 10 hairs into the same group; the most frequently occurring group was used for analysis. The inter-rater agreement was poor for the 8-groups (k = 0.418) but improved for the 6-groups (k = 0.671). The intra-rater agreement also improved (k = 0.444 to 0.648 versus 0.599 to 0.836) for 6-groups; that for the one evaluator for all volunteers was good (k = 0.754). Although small, this is the first study to test the reliability of a geometric classification. The 6-group method is more reliable. However, a digital classification system is likely to reduce operator error. A reliable objective classification of human hair curl is long overdue, particularly with the increasing use of hair as a testing substrate for treatment compliance in Medicine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weston, Louise Marie
2007-09-01
A recent report on criticality accidents in nuclear facilities indicates that human error played a major role in a significant number of incidents with serious consequences and that some of these human errors may be related to the emotional state of the individual. A pre-shift test to detect a deleterious emotional state could reduce the occurrence of such errors in critical operations. The effectiveness of pre-shift testing is a challenge because of the need to gather predictive data in a relatively short test period and the potential occurrence of learning effects due to a requirement for frequent testing. This reportmore » reviews the different types of reliability and validity methods and testing and statistical analysis procedures to validate measures of emotional state. The ultimate value of a validation study depends upon the percentage of human errors in critical operations that are due to the emotional state of the individual. A review of the literature to identify the most promising predictors of emotional state for this application is highly recommended.« less
Superconducting Magnetic Energy Storage (SMES) Program
NASA Astrophysics Data System (ADS)
Rogers, J. D.
1985-05-01
The 30 MJ, 10 MW superconducting magnetic energy storage (SMES) system was devised to interact in the Western US Power System as an alternate means to damp unstable oscillations at 0.35 Hz on the Pacific HVAC Interites. The operating limits of the 30 MJ SMES unit were established, and different means of controlling real and reactive power were tested. The unit can follow a sinusoidal power demand signal with an amplitude of up to 8.6 MW with the converter working in a 12 pulse mode. When the converter operates in the constant VAR mode, a time varying real power demand signal of up to 5 MW can be met. It was shown that the Pacific ac Interite has current and reactive power variations of the same frequency as the modulating frequency of the SMES device. The reliability of the SMES subsystems with a narrow band noise input was assessed. Parameters of the ac power system were determined. Converter short circuit tests, load tests under various control conditions, dc breaker tests for coil current interruption, and converter failure mode tests were conducted. The experimental operation of the SMES system is concluded.
Ma, Wei-Fen; Wu, Po-Lun; Yang, Shu-Ju; Cheng, Kuang-Fu; Chiu, Hsien-Tsai; Lane, Hsien-Yuan
2010-12-01
Early interventions can improve treatment outcomes for individuals with major psychiatric disorders and with nonspecific symptoms but increasingly impaired cognitive perception, emotions, and behaviour. One way used to identify people susceptible to psychosis is through the schizotypal personality trait. Persons with schizotypal characteristics have been identified with the widely used Schizotypal Personality Questionnaire-Brief. However, no suitable instruments are available to screen individuals in the Taiwanese population for evidence of early psychotic symptoms. The purpose of this study was to test the sensitivity and specificity of the Chinese version of the Schizotypal Personality Questionnaire-Brief for identifying undergraduate students' susceptibility to psychosis. Two-stage, cross-sectional survey design. The self-administered scale was tested in a convenience sample of 618 undergraduate students at a medical university in Taiwan. Among these students, 54 completed the scale 2 weeks apart for test-retest reliability, and 80 were tested to identify their susceptibility to psychosis. In Stage I, participants with scores in the top 6.5% were classified as the high-score group (n=40). The control group (n=40) was randomly selected from the remaining participants with scores <15 and matched by gender. These 80 students were asked to participate in psychiatric interviews in Stage II. The instrument was tested for reliability using intraclass correlation coefficients and the Kuder-Richardson formula 20. The instrument was analysed for optimal sensitivity and specificity using odds-ratio analysis and receiver operating characteristic curves. The 22-item Chinese version of the Schizotypal Personality Questionnaire-Brief had a 2-week test-retest reliability of 0.82 and internal consistency of 0.76. The optimal cut-off score was 17, with odds ratios of 24.4 and an area under the receiver operating characteristic curves of 0.83. The instrument had a sensitivity of 80.0% and specificity of 85.9% in identifying undergraduate students' susceptibility to psychosis. The Chinese version Schizotypal Personality Questionnaire-Brief is a reliable instrument, but should not be used as a screening tool until its psychometric properties have been evaluated in more detail. Other screening tools need to be used in future studies with the CSPQ-B to improve the accuracy of identifying susceptibility to psychosis among young adults. Copyright © 2010. Published by Elsevier Ltd.
McMahon, Terry W; Newman, David G
2016-04-01
Flying a helicopter is a complex psychomotor skill. Fatigue is a serious threat to operational safety, particularly for sustained helicopter operations involving high levels of cognitive information processing and sustained time on task. As part of ongoing research into this issue, the object of this study was to develop a field-deployable helicopter-specific psychomotor vigilance test (PVT) for the purpose of daily performance monitoring of pilots. The PVT consists of a laptop computer, a hand-operated joystick, and a set of rudder pedals. Screen-based compensatory tracking task software includes a tracking ball (operated by the joystick) which moves randomly in all directions, and a second tracking ball which moves horizontally (operated by the rudder pedals). The 5-min test requires the pilot to keep both tracking balls centered. This helicopter-specific PVT's portability and integrated data acquisition and storage system enables daily field monitoring of the performance of individual helicopter pilots. The inclusion of a simultaneous foot-operated tracking task ensures divided attention for helicopter pilots as the movement of both tracking balls requires simultaneous inputs. This PVT is quick, economical, easy to use, and specific to the operational flying task. It can be used for performance monitoring purposes, and as a general research tool for investigating the psychomotor demands of helicopter operations. While reliability and validity testing is warranted, data acquired from this test could help further our understanding of the effect of various factors (such as fatigue) on helicopter pilot performance, with the potential of contributing to helicopter operational safety.
1991-02-01
FY 1990 ACCOMPLISHMENTS: a. (U) Completed physical functional and operational audit of system, subcomponents and interfaces related to digital...receiver hardware. b. (U) Developed system specification reflecting audit results. c. (U) Established reliability assessment and recommended changes and/or...interoperability testing and demonstrations. d. (U) Updated joint terminal specifications and standards. e. (U) Audited Army/Navy/Air Force terminal designs. f. (U
Oximeter reliability in a subzero environment.
Macnab, A J; Smith, M; Phillips, N; Smart, P
1996-11-01
Pulse oximeters optimize care in the pre-hospital setting. As British Columbia ambulance teams often provide care in subzero temperatures, we conducted a study to determine the reliability of 3 commercially-available portable oximeters in a subzero environment. We hypothesized that there is no significant difference between SaO2 readings obtained using a pulse oximeter at room temperature and a pulse oximeter operating at sub-zero temperatures. Subjects were stable normothermic children in intensive care on Hewlett Packard monitors (control unit) at room temperature. The test units were packed in dry ice in an insulated bin (temperature - 15 degrees C to -30 degrees C) and their sensors placed on the subjects, contralateral to the control sensors. Data were collected simultaneously from test and control units immediately following validation of control unit values by co-oximetry (blood gas). No data were unacceptable. Two units (Propaq 106EC and Nonin 8500N) functioned well to < -15 degrees C, providing data comparable to those obtained from the control unit (p < 0.001). The Siemens Micro O2 did not function at the temperatures tested. Monitor users who require equipment to function in subzero environments (military, Coast Guard, Mountain Rescue) should ensure that function is reliable, and could test units using this method.
An Analysis of Operational Suitability for Test and Evaluation of Highly Reliable Systems
1994-03-04
Exposition," Journal of the American Statistical A iation-59: 353-375 (June 1964). 17. SYS 229, Test and Evaluation Management Coursebook , School of Systems...in hours, 0 is 2-5 the desired MTBCF in hours, R is the number of critical failures, and a is the P[type-I error] of the X2 statistic with 2*R+2...design of experiments (DOE) tables and the use of Bayesian statistics to increase the confidence level of the test results that will be obtained from
Urinary cotinine testing as pre-operative assessment of patients undergoing free flap surgery.
Reinbold, C; Rausky, J; Binder, J-P; Revol, M
2015-02-01
The identified risks of smoking with regard to operated tissues are so elevated that it is clearly dangerous to operate a smoker when the proposed intervention is neither vital nor urgent. The aim of this prospective study was to evaluate a simple method of screening patients who smoke, with the evaluation carried out before agreeing to carry out free tissue transfer. The purpose of the testing was to hold the patient responsible for his actions and minimize smoking-related complications by cancelling or postponing the planned operation if the patient continued to smoke. Screening included use of a standardized questionnaire at the first consultation and detection of cotinine using a urine test strip 7 days before the scheduled surgery. Patients were informed that in the event of positive results, the operation would not take place. A six-week preoperative smoking cessation period was mandatory. Seventy-six patients were included in this study. Among them, 25 (32.9%) reported being former smokers and 11 (14.5%) admitted in the initial questionnaire to being active smokers. Six patients (7.9%), including one self-reported non-smoker, tested positive for cotinine, and their operations were cancelled. Screening using a questionnaire and cotinine detection appeared to constitute a simple, inexpensive, rapid and reliable test. It allowed us to refuse to operate 6 non-compliant patients and was thereby likely to diminish morbidity in the free tissue transfers carried out in our ward. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kercel, S.W.; Baylor, V.M.; Labaj, L.E.
Enclosed Space Detection System (ESDS) is a fast, inexpensive, and reliable device for detecting human occupants hidden in vehicles. Operation requires less than two minutes. ESDS is used to foil attempts at smuggling illegal aliens, terrorists, and escaping prisoners. It is being tested at nuclear weapons facilities and has been operated at several prisons and international border crossings. ESDS is the first practical electronic alternative to physical searches of vehicles for hidden passengers. At critical checkpoints, a thorough physical search of a single fully loaded truck requires a team of from two to six people, and may take as longmore » as eight hours. Despite this level of security, experience has shown that the search can occasionally be foiled. Due to the enormous time and expense of thorough physical searches of vehicles, they are seldom conducted at any but the most critical of locations, simply leaving many sites vulnerable to crime and terrorism. Prior to the development of the ESDS, the only other effective alternative to physical search was the use of specially-trained canines, which can be vastly superior to the physical search in both time and accuracy. However, as discussed in this paper, canine inspection is not really a competitive substitute for ESDS because canine reliability (80% at most) is not as high as that of the ESDS (99%+), while the costs, training requirements, and operator skill needed are significantly higher with canines than with the ESDS. In addition, the ESDS has straightforward self-diagnostic tests to ensure the system is operating correctly; such tests are not currently available with either canine or human inspectors. ESDS offers an attractive supplement or alternative to meet current security requirements for vehicle searches at portals at government, nuclear, industrial, and other facilities where concealed persons may pose a threat either by entering or leaving.« less
Mahmoud, Asmaa; Abundo, Paolo; Basile, Luisanna; Albensi, Caterina; Marasco, Morena; Bellizzi, Letizia; Galasso, Franco; Foti, Calogero
2017-01-01
In spite the instinct social&financial impact of Leg Length Discrepancy (LLD), controversial and conflicting results still exist regarding a reliable assessment/correction method. For proper management it's essential to discriminate between anatomical&functional Leg Length Discrepancy (FLLD). With the newly invented NPoS (New Postural Solution), under the umbrella of the collaboration of PRM Department, Tor Vergata University with Baro Postural Instruments srl, positive results were observed in both measuring& compensating the hemi-pelvic antero-medial rotation in FLLD through personalized bilateral heel raise using two NPoS components: Foot Image System (FIS) and Postural Optimizer System (POS). This led our research interest to test the validity of NPoS as a preliminary step before evaluating its implementations in postural disorders. After clinical evaluation, 4 subjects with FLLD have been assessed by NPoS. Over a period of 2 months, every subject was evaluated 12 times by two different operators, 48 measurements in total, results have been verified in correlation to BTS GaitLab results. Intra-Operator&inter-operator variability analysis showed statistically insignificant differences, while inter-method variability between NPoS and BTS parameters expressed a linear correlation. Results suggest a significant validity of NPoS in assessment&correction of FLLD, with high degree of reproducibility with minimal operator dependency. This can be considered a base for promising clinical implications of NPoS as a reliable cost effective postural assessment/corrective tool. V.
NASA Technical Reports Server (NTRS)
Thomes, W. Joe; Ott, Melanie N.; Chuska, Richard; Switzer, Robert; Onuma, Eleanya; Blair, Diana; Frese, Erich; Matyseck, Marc
2016-01-01
Fiber optic assemblies have been used on spaceflight missions for many years as an enabling technology for routing, transmitting, and detecting optical signals. Due to the overwhelming success of NASA in implementing fiber optic assemblies on spaceflight science-based instruments, system scientists increasingly request fibers that perform in extreme environments while still maintaining very high optical transmission, stability, and reliability. Many new applications require fiber optic assemblies that will operate down to cryogenic temperatures as low as 20 Kelvin. In order for the fiber assemblies to operate with little loss in optical throughput at these extreme temperatures requires a system level approach all the way from how the fiber assembly is manufactured to how it is held, routed, and integrated. The NASA Goddard Code 562 Photonics Group has been designing, manufacturing, testing, and integrating fiber optics for spaceflight and other high reliability applications for nearly 20 years. Design techniques and lessons learned over the years are consistently applied to developing new fiber optic assemblies that meet these demanding environments. System level trades, fiber assembly design methods, manufacturing, testing, and integration will be discussed. Specific recent examples of ground support equipment for the James Webb Space Telescope (JWST); the Ice, Cloud and Land Elevation Satellite-2 (ICESat-2); and others will be included.
NASA Astrophysics Data System (ADS)
Thomes, W. Joe; Ott, Melanie N.; Chuska, Richard; Switzer, Robert; Onuma, Eleanya; Blair, Diana; Frese, Erich; Matyseck, Marc
2016-09-01
Fiber optic assemblies have been used on spaceflight missions for many years as an enabling technology for routing, transmitting, and detecting optical signals. Due to the overwhelming success of NASA in implementing fiber optic assemblies on spaceflight science-based instruments, system scientists increasingly request fibers that perform in extreme environments while still maintaining very high optical transmission, stability, and reliability. Many new applications require fiber optic assemblies that will operate down to cryogenic temperatures as low as 20 Kelvin. In order for the fiber assemblies to operate with little loss in optical throughput at these extreme temperatures requires a system level approach all the way from how the fiber assembly is manufactured to how it is held, routed, and integrated. The NASA Goddard Code 562 Photonics Group has been designing, manufacturing, testing, and integrating fiber optics for spaceflight and other high reliability applications for nearly 20 years. Design techniques and lessons learned over the years are consistently applied to developing new fiber optic assemblies that meet these demanding environments. System level trades, fiber assembly design methods, manufacturing, testing, and integration will be discussed. Specific recent examples of ground support equipment for the James Webb Space Telescope (JWST); the Ice, Cloud and Land Elevation Satellite-2 (ICESat- 2); and others will be included.
Composite Overwrapped Pressure Vessels (COPV): Flight Rationale for the Space Shuttle Program
NASA Technical Reports Server (NTRS)
Kezirian, Michael T.; Johnson, Kevin L.; Phoenix, Stuart L.
2011-01-01
Each Orbiter Vehicle (Space Shuttle Program) contains up to 24 Kevlar49/Epoxy Composite Overwrapped Pressure Vessels (COPV) for storage of pressurized gases. In the wake of the Columbia accident and the ensuing Return To Flight (RTF) activities, Orbiter engineers reexamined COPV flight certification. The original COPV design calculations were updated to include recently declassified Kevlar COPV test data from Lawrence Livermore National Laboratory (LLNL) and to incorporate changes in how the Space Shuttle was operated as opposed to orinigially envisioned. 2005 estimates for the probability of a catastrophic failure over the life of the program (from STS-1 through STS-107) were one-in-five. To address this unacceptable risk, the Orbiter Project Office (OPO) initiated a comprehensive investigation to understand and mitigate this risk. First, the team considered and eventually deemed unfeasible procuring and replacing all existing flight COPVs. OPO replaced the two vessels with the highest risk with existing flight spare units. Second, OPO instituted operational improvements in ground procedures to signficiantly reduce risk, without adversely affecting Shuttle capability. Third, OPO developed a comprehensive model to quantify the likelihood of occurrance. A fully-instrumented burst test (recording a lower burst pressure than expected) on a flight-certified vessel provided critical understanding of the behavior of Orbiter COPVs. A more accurate model was based on a newly-compiled comprehensive database of Kevlar data from LLNL and elsewhere. Considering hardware changes, operational improvements and reliability model refinements, the mean reliability was determined to be 0.998 for the remainder of the Shuttle Program (from 2007, for STS- 118 thru STS-135). Since limited hardware resources precluded full model validation through multiple tests, additional model confidence was sought through the first-ever Accelerated Stress Rupture Test (ASRT) of a flown flight article. A Bayesian statistical approach was developed to interpret possible test results. Since the lifetime observed in the ASRT exceeded initial estimates by one to two orders of magnitude, the Space Shuttle Program deemed there was significant conservatism in the model and accepted continued operation with existing flight hardware. Given the variability in tank-to-tank original prooftest response, a non-destructive evaluation (NDE) technique utilizing Raman Spectroscopy was developed to directly measure COPV residual stress state. Preliminary results showed that patterns of low fiber elastic strains over the outside vessel surface, together with measured permanent volume growth during proof, could be directly correlated to increased fiber stress ratios on the inside fibers adjacent to the liner, and thus reduced reliability.
The Arthroscopic Surgical Skill Evaluation Tool (ASSET).
Koehler, Ryan J; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Bramen, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J; Nicandri, Gregg T
2013-06-01
Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice; however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability when used to assess the technical ability of surgeons performing diagnostic knee arthroscopic surgery on cadaveric specimens. Cross-sectional study; Level of evidence, 3. Content validity was determined by a group of 7 experts using the Delphi method. Intra-articular performance of a right and left diagnostic knee arthroscopic procedure was recorded for 28 residents and 2 sports medicine fellowship-trained attending surgeons. Surgeon performance was assessed by 2 blinded raters using the ASSET. Concurrent criterion-oriented validity, interrater reliability, and test-retest reliability were evaluated. Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in the total ASSET score (P < .05) between novice, intermediate, and advanced experience groups were identified. Interrater reliability: The ASSET scores assigned by each rater were strongly correlated (r = 0.91, P < .01), and the intraclass correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: There was a significant correlation between ASSET scores for both procedures attempted by each surgeon (r = 0.79, P < .01). The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopic surgery in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live operating room and other simulated environments.
Constructing the "Best" Reliability Data for the Job
NASA Technical Reports Server (NTRS)
DeMott, D. L.; Kleinhammer, R. K.
2014-01-01
Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.
Constructing the Best Reliability Data for the Job
NASA Technical Reports Server (NTRS)
Kleinhammer, R. K.; Kahn, J. C.
2014-01-01
Modern business and technical decisions are based on the results of analyses. When considering assessments using "reliability data", the concern is how long a system will continue to operate as designed. Generally, the results are only as good as the data used. Ideally, a large set of pass/fail tests or observations to estimate the probability of failure of the item under test would produce the best data. However, this is a costly endeavor if used for every analysis and design. Developing specific data is costly and time consuming. Instead, analysts rely on available data to assess reliability. Finding data relevant to the specific use and environment for any project is difficult, if not impossible. Instead, we attempt to develop the "best" or composite analog data to support our assessments. One method used incorporates processes for reviewing existing data sources and identifying the available information based on similar equipment, then using that generic data to derive an analog composite. Dissimilarities in equipment descriptions, environment of intended use, quality and even failure modes impact the "best" data incorporated in an analog composite. Once developed, this composite analog data provides a "better" representation of the reliability of the equipment or component can be used to support early risk or reliability trade studies, or analytical models to establish the predicted reliability data points. Data that is more representative of reality and more project specific would provide more accurate analysis, and hopefully a better final decision.
Testing military grade magnetics (transformers, inductors and coils).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Engineers and designers are constantly searching for test methods to qualify or 'prove-in' new designs. In the High Reliability world of military parts, design test, qualification tests, in process tests and product characteristic tests, become even more important. The use of in process and function tests has been adopted as a way of demonstrating that parts will operate correctly and survive its 'use' environments. This paper discusses various types of tests to qualify the magnetic components - the current carrying capability of coils, a next assembly 'as used' test, a corona test and inductance at temperature test. Each of thesemore » tests addresses a different potential failure on a component. The entire process from design to implementation is described.« less
NASA Astrophysics Data System (ADS)
Kwok, Yu Fat
The main objective of this study is to develop a model for the determination of optimum testing interval (OTI) of non-redundant standby plants. This study focuses on the emergency power generators in tall buildings in Hong Kong. The model for the reliability, which is developed, is applicable to any non-duplicated standby plant. In a tall building, the mobilisation of occupants is constrained by its height and the building internal layout. Occupant's safety, amongst other safety considerations, highly depends on the reliability of the fire detection and protection system, which in turn is dependent on the reliability of the emergency power generation plants. A thorough literature survey shows that the practice used in determining OTI in nuclear plants is generally applicable. Historically, the OTI in these plants is determined by balancing the testing downtime and reliability gained from frequent testing. However, testing downtime does not exist in plants like emergency power generator. Subsequently, sophisticated models have taken repairing downtime into consideration. In this study, the algorithms for the determination of OTI, and hence reliability of standby plants, are reconsidered. A new concept is introduced into the subject. A new model is developed for such purposes which embraces more realistic factors found in practice. System aging and the finite life cycle of the standby plant are considered. Somewhat more pragmatic is that the Optimum Overhauling Interval can also be determined from this new model. System unavailability grow with time, but can be reset by test or overhaul. Contrary to fixed testing intervals, OTI is determined whenever system point unavailability exceeds certain level, which depends on the reliability requirement of the standby system. An optimum testing plan for lowering this level to the 'minimum useful unavailability' level (see section 9.1 for more elaboration) can be determined by the new model presented. Cost effectiveness is accounted for by a new parameter 'tau min', the minimum testing interval (MTI). The MTI optimises the total number of tests and the total number of overhauls, when the costs for each are available. The model sets up criteria for test and overhaul and to 'announce' end of system life. The usefulness of the model is validated by a detailed analysis of the operating parameters from 8,500 maintenance records collected for emergency power generation plants in high rise buildings in Hong Kong. (Abstract shortened by UMI.)
NASA Technical Reports Server (NTRS)
Yew, Calinda; Lui, Yan; Whitehouse, Paul; Banks, Kimberly
2016-01-01
JWST Integrated Science Instruments Module (ISIM) completed its system-level space simulation testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered to the next level of integration with the Optical Telescope Element (OTE), to form OTIS (OTE + ISIM), after concluding a series of three cryo-vacuum (CV) tests. During these tests, the complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration following mechanical environmental tests (vibration and acoustics). From one test to the next, shortcomings of the facility were uncovered and associated improvements in operational capabilities and reliability of the facility were required to enable the project to verify system-level requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.
NASA Astrophysics Data System (ADS)
Ramesham, Rajeshuni
2013-03-01
Life testing/qualification of reflowed (1st reflow) and reworked (1st reflow, 1st removal, and then 1st rework) advanced ceramic column grid array (CCGA) surface mount interconnect electronic packaging technologies for future flight projects has been studied to enhance the mission assurance of JPL-NASA projects. The reliability of reworked/reflowed surface mount technology (SMT) packages is very important for short-duration and long-duration deep space harsh extreme thermal environmental missions. The life testing of CCGA electronic packages under extreme thermal environments (for example: -185°C to +125°C) has been performed with reference to various JPL/NASA project requirements which encompass the temperature range studied. The test boards of reflowed and reworked CCGA packages (717 Xilinx package, 624, 1152, and 1272 column Actel Packages) were selected for the study to survive three times the total number of expected temperature cycles resulting from all environmental and operational exposures occurring over the life of the flight hardware including all relevant manufacturing, ground operations, and mission phases or cycles to failure to assess the life of the hardware. Qualification/life testing was performed by subjecting test boards to the environmental harsh temperature extremes and assessing any structural failures, mechanical failures or degradation in electrical performance solder-joint failures due to either overstress or thermal cycle fatigue. The large, high density, high input/output (I/O) electronic interconnect SMT packages such as CCGA have increased usage in avionics hardware of NASA projects during the last two decades. The test boards built with CCGA packages are expensive and often require a rework to replace a reflowed, reprogrammed, failed, redesigned, etc., CCGA packages. Theoretically speaking, a good rework process should have similar temperature-time profile as that used for the original manufacturing process of solder reflow. A multiple rework processes may be implemented with CCGA packaging technology to understand the effect of number of reworks on the reliability of this technology for harsh thermal environments. In general, reliability of the assembled electronic packages reduces as a function of number of reworks and the extent is not known yet. A CCGA rework process has been tried and implemented to design a daisy-chain test board consists of 624 and 717 packages. Reworked CCGA interconnect electronic packages of printed wiring polyimide boards have been assembled and inspected using non-destructive x-ray imaging and optical microscope techniques. The assembled boards after 1st rework and 1st reflow were subjected to extreme temperature thermal atmospheric cycling to assess their reliability for future deep space JPL/NASA for moderate to harsh thermal mission environments. The resistance of daisy-chained interconnect sections were monitored continuously during thermal cycling to determine intermittent failures. This paper provides the experimental reliability test results to failure of assemblies for the first time of reflowed and reworked CCGA packages under extreme harsh thermal environments.
Reliability and Validity of Bedside Version of Persian WAB (P-WAB-1).
Nilipour, Reza; Pourshahbaz, Abbas; Ghoreyshi, Zahra Sadat
2014-10-01
In this study, we reported the reliability and validity of Bedside version of Persian WAB (P-WAB-1) adapted from Western Aphasia Battery (WAB-R) (1,2). P-WAB-1 is a clinical linguistic measuring tool to determine severity and type of aphasia in brain damaged patients based on Aphasia Quotient (AQ) as a functional measure. For the purposes of a quick clinical screening of aphasia in Persian, we adapted the bedside version of WAB-R to assess the performance of Persian aphasic patients. The data we reported on adaptation, validity and reliability of P-WAB-1 are based on faithful translation and criterion validity ratio (CVR) taken from the expert panel and the performance of 60 consecutive brain damaged patients referred to different university clinics for rehabilitation and 30 healthy subjects as norms and 40 age-matched epileptic patients as the control group. Based on the results of this study, P-WAB-1 has internal consistency (a=0.71) and test-retest reliability (r=.65 P<0.001) and the subtests are sensitive enough to contribute to Aphasia Quotient (AQ) as a functional measure of severity of aphasia in Iranian brain damaged patients. Based on AQ results, our aphasic patients were classified into four distinct groups of severity. P-WAB-1 is the first clinical linguistic test to determine severity of aphasia based on an operational index and can be considered as a valid baseline for screening and diagnosis of aphasia among Persian speaking brain damaged patients. This study is the initial step on adaptation of different versions of WAB-R to measure the severity of aphasia using AQ, LQ and CQ as operational measures and to classify Persian speaking aphasic patients into different types.
Ultimately Reliable Pyrotechnic Systems
NASA Technical Reports Server (NTRS)
Scott, John H.; Hinkel, Todd
2015-01-01
This paper presents the methods by which NASA has designed, built, tested, and certified pyrotechnic devices for high reliability operation in extreme environments and illustrates the potential applications in the oil and gas industry. NASA's extremely successful application of pyrotechnics is built upon documented procedures and test methods that have been maintained and developed since the Apollo Program. Standards are managed and rigorously enforced for performance margins, redundancy, lot sampling, and personnel safety. The pyrotechnics utilized in spacecraft include such devices as small initiators and detonators with the power of a shotgun shell, detonating cord systems for explosive energy transfer across many feet, precision linear shaped charges for breaking structural membranes, and booster charges to actuate valves and pistons. NASA's pyrotechnics program is one of the more successful in the history of Human Spaceflight. No pyrotechnic device developed in accordance with NASA's Human Spaceflight standards has ever failed in flight use. NASA's pyrotechnic initiators work reliably in temperatures as low as -420 F. Each of the 135 Space Shuttle flights fired 102 of these initiators, some setting off multiple pyrotechnic devices, with never a failure. The recent landing on Mars of the Opportunity rover fired 174 of NASA's pyrotechnic initiators to complete the famous '7 minutes of terror.' Even after traveling through extreme radiation and thermal environments on the way to Mars, every one of them worked. These initiators have fired on the surface of Titan. NASA's design controls, procedures, and processes produce the most reliable pyrotechnics in the world. Application of pyrotechnics designed and procured in this manner could enable the energy industry's emergency equipment, such as shutoff valves and deep-sea blowout preventers, to be left in place for years in extreme environments and still be relied upon to function when needed, thus greatly enhancing safety and operational availability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizzo, Jeffrey J.
2010-04-30
The Wabash gasification facility, owned and operated by sgSolutions LLC, is one of the largest single train solid fuel gasification facilities in the world capable of transforming 2,000 tons per day of petroleum coke or 2,600 tons per day of bituminous coal into synthetic gas for electrical power generation. The Wabash plant utilizes Phillips66 proprietary E-Gas (TM) Gasification Process to convert solid fuels such as petroleum coke or coal into synthetic gas that is fed to a combined cycle combustion turbine power generation facility. During plant startup in 1995, reliability issues were realized in the gas filtration portion of themore » gasification process. To address these issues, a slipstream test unit was constructed at the Wabash facility to test various filter designs, materials and process conditions for potential reliability improvement. The char filtration slipstream unit provided a way of testing new materials, maintenance procedures, and process changes without the risk of stopping commercial production in the facility. It also greatly reduced maintenance expenditures associated with full scale testing in the commercial plant. This char filtration slipstream unit was installed with assistance from the United States Department of Energy (built under DOE Contract No. DE-FC26-97FT34158) and began initial testing in November of 1997. It has proven to be extremely beneficial in the advancement of the E-Gas (TM) char removal technology by accurately predicting filter behavior and potential failure mechanisms that would occur in the commercial process. After completing four (4) years of testing various filter types and configurations on numerous gasification feed stocks, a decision was made to investigate the economic and reliability effects of using a particulate removal gas cyclone upstream of the current gas filtration unit. A paper study had indicated that there was a real potential to lower both installed capital and operating costs by implementing a char cyclonefiltration hybrid unit in the E-Gas (TM) gasification process. These reductions would help to keep the E-Gas (TM) technology competitive among other coal-fired power generation technologies. The Wabash combined cyclone and gas filtration slipstream test program was developed to provide design information, equipment specification and process control parameters of a hybrid cyclone and candle filter particulate removal system in the E-Gas (TM) gasification process that would provide the optimum performance and reliability for future commercial use. The test program objectives were as follows: 1. Evaluate the use of various cyclone materials of construction; 2. Establish the optimal cyclone efficiency that provides stable long term gas filter operation; 3. Determine the particle size distribution of the char separated by both the cyclone and candle filters. This will provide insight into cyclone efficiency and potential future plant design; 4. Determine the optimum filter media size requirements for the cyclone-filtration hybrid unit; 5. Determine the appropriate char transfer rates for both the cyclone and filtration portions of the hybrid unit; 6. Develop operating procedures for the cyclone-filtration hybrid unit; and, 7. Compare the installed capital cost of a scaled-up commercial cyclone-filtration hybrid unit to the current gas filtration design without a cyclone unit, such as currently exists at the Wabash facility.« less
Takeuchi, Hiroyoshi; Fervaha, Gagan; Lee, Jimmy; Agid, Ofer; Remington, Gary
2016-09-01
Brief assessments have the potential to be widely adopted as outcome measures in research but also routine clinical practice. Existing brief rating scales that assess symptoms of schizophrenia or psychosis have a number of limitations including inability to capture five symptom domains of psychosis and a lack of clearly defined operational anchor points for scoring. We developed a new brief rating scale for five symptom domains of psychosis with clearly defined operational anchor points - the Brief Evaluation of Psychosis Symptom Domains (BE-PSD). To examine the psychometric properties of the BE-PSD, fifty patients with schizophrenia or schizoaffective disorder were included in this preliminary cross-sectional study. To test the convergent and discriminant validity of the BE-PSD, correlational analyses were employed using the consensus Positive and Negative Syndrome Scale (PANSS) five-factor model. To examine the inter-rater reliability of the BE-PSD, single measures intraclass correlation coefficients (ICCs) were calculated for 11 patients. The BE-PSD domain scores demonstrated high convergent validity with the corresponding PANSS factor score (rs = 0.81-0.93) as well as good discriminant validity, as evidenced by lower correlations with the other PANSS factors (rs = 0.23-0.62). The BE-PSD also demonstrated excellent inter-rater reliability for each of the domain scores and the total scores (ICC(2,1) = 0.79-0.96). The present preliminary study found the BE-PSD measure to be valid and reliable; however, further studies are needed to establish the psychometric properties of the BE-PSD because of the limitations such as the small sample size and lacking data on test-retest reliability or sensitivity to change. Copyright © 2016 Elsevier Ltd. All rights reserved.
Beardsley, Chris; Egerton, Tim; Skinner, Brendon
2016-01-01
Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.
Reliability on ISS Talk Outline
NASA Technical Reports Server (NTRS)
Misiora, Mike
2015-01-01
1. Overview of ISS 2. Space Environment and it effects a. Radiation b. Microgravity 3. How we ensure reliability a. Requirements b. Component Selection i. Note: I plan to stay away from talk about Rad Hardened components and talk about why we use older processors because they are less susceptible to SEUs. c. Testing d. Redundancy / Failure Tolerance e. Sparing strategies 4. Operational Examples a. Multiple MDM Failures on 6A due to hard drive failure In general, my plan is to only talk about data that is currently available via normal internet sources to ensure that I stay away from any topics that would be Export Controlled, ITAR, or NDA-controlled. The operational example has been well-reported on in the media and those are the details that I plan to cover. Additionally I am not planning on using any slides or showing any photos during the talk.
Magnetic refrigeration for maser amplifier cooling
NASA Technical Reports Server (NTRS)
Johnson, D. L.
1982-01-01
The development of a multifrequency upconverter-maser system for the DSN has created the need to develop a closed-cycle refrigerator (CCR) capable of providing more than 3 watts of refrigeration capability at 4.5 K. In addition, operating concerns such as the high cost of electrical power consumption and the loss of maser operation due to CCR failures require that improvements be made to increase the efficiency and reliability of the CCR. One refrigeration method considered is the replacement of the Joule-Thomson expansion circuit with a magnetic refrigeration. Magnetic refrigerators can provide potentially reliable and highly efficient refrigeration at a variety of temperature ranges and cooling power. The concept of magnetic refrigeration is summarized and a literature review of existing magnetic refrigerator designs which have been built and tested and that may also be considered as possibilities as a 4 K to 15 K magnetic refrigeration stage for the DSN closed-cycle refrigerator is provided.
Rapid Inspection of Aerospace Structures - Is It Autonomous Yet?
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph; Backes, Paul; Joffe, Benjamin
1996-01-01
The trend to increase the usage of aging aircraft added a great deal of urgency to the ongoing need for low-cost, rapid, simple-to-operate, reliable and efficient NDE methods for detection and characterization of flaws in aircraft structures. In many cases, the problem of inspection is complex due to the limitation of current technology and the need to disassemble aircraft structures and testing them in lab conditions. To overcome these limitations, reliable field inspection tools are being developed for rapid NDE of large and complex-shape structures, that can operate at harsh, hostal and remote conditions with minimum human interface. In recent years, to address the need for rapid inspection in field conditions, numerous portable scanners were developed using NDE methods, including ultrasonics, shearography, thermography. This paper is written with emphasis on ultrasonic NDE scanners, their evolution and the expected direction of growth.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu, Jiajia; Zhao, Lixia, E-mail: lxzhao@semi.ac.cn, E-mail: jmli@semi.ac.cn; Cao, Haicheng
The degradation behaviors of high power GaN-based vertical blue LEDs on Si substrates were measured using in-situ accelerated life test. The results show that the dominant failure mechanism would be different during the operation. Besides that, the corresponding associated failure mechanisms were investigated systematically by using different analysis technologies, such as Scan Electron Microscopy, Reflectivity spectroscopy, Transient Thermal Analysis, Raman Spectra, etc. It is shown that initially, the failure modes were mainly originated from the semiconductor die and interconnect, while afterwards, the following serious deterioration of the radiant fluxes was attributed to the package. The interface material and quality, suchmore » as die attach and frame, play an important role in determining the thermal performance and reliability. In addition, the heating effect during the operation will also release the compressive strain in the chip. These findings will help to improve the reliability of GaN-based LEDs, especially for the LEDs with vertical structure.« less
NASA Technical Reports Server (NTRS)
Wieland, P.; Hutchens, C.; Long, D.; Salyer, B.
1998-01-01
Wastewater and urine generated on the International Space Station will be processed to recover pure water using vapor compression distillation (VCD). To verify the long-term reliability and performance of the VCD Urine Processor Assembly (UPA), life testing was performed at the Marshall Space Flight Center (MSFC) from January 1993 to April 1996. Two UPA'S, the VCD-5 and VCD-5A, were tested for 204 days and 665 days, respectively. The compressor gears and the distillation centrifuge drive belt were found to have operating lives of approximately 4,800 hours, equivalent to 3.9 years of operation on ISS for a crew of three at an average processing rate of 1.76 kg/h (3.97 lb/h). Precise alignment of the flex-splines of the fluids and purge pump motor drives is essential to avoid premature failure after about 400 hours of operation. Results indicate that, with some design and procedural modifications and suitable quality control, the required performance and operational life can be met with the VCD/UPA.
NASA Astrophysics Data System (ADS)
Maccari, Augusto; Donnola, Sandro; Matino, Francesca; Tamano, Shiro
2016-05-01
Since July 2013, the first stand-alone Molten Salt Parabolic Trough (MSPT) demo plant, which was built in collaboration with Archimede Solar Energy and Chiyoda Corporation, is in operation, located adjacent to the Archimede Solar Energy (ASE) manufacturing plant in Massa Martana (Italy). During the two year's operating time frame, the management of the demo plant has shown that MSPT technology is a suitable and reliable option. Several O&M procedures and tests have been performed, as Heat Loss and Minimum Flow Test, with remarkable results confirming that this technology is ready to be extended to standard size CSP plant, if the plant design takes into account molten salt peculiarities. Additionally, the plant has been equipped on fall 2014 with a Steam Generator system by Chiyoda Corporation, in order to test even this important MSPT plant subsystem and to extend the solar field active time, overcoming the previous lack of an adequate thermal load. Here, a description of the plant improvements and the overall plant operation figures will be presented.
The ITER Neutral Beam Test Facility towards SPIDER operation
NASA Astrophysics Data System (ADS)
Toigo, V.; Dal Bello, S.; Gaio, E.; Luchetta, A.; Pasqualotto, R.; Zaccaria, P.; Bigi, M.; Chitarin, G.; Marcuzzi, D.; Pomaro, N.; Serianni, G.; Agostinetti, P.; Agostini, M.; Antoni, V.; Aprile, D.; Baltador, C.; Barbisan, M.; Battistella, M.; Boldrin, M.; Brombin, M.; Dalla Palma, M.; De Lorenzi, A.; Delogu, R.; De Muri, M.; Fellin, F.; Ferro, A.; Gambetta, G.; Grando, L.; Jain, P.; Maistrello, A.; Manduchi, G.; Marconato, N.; Pavei, M.; Peruzzo, S.; Pilan, N.; Pimazzoni, A.; Piovan, R.; Recchia, M.; Rizzolo, A.; Sartori, E.; Siragusa, M.; Spada, E.; Spagnolo, S.; Spolaore, M.; Taliercio, C.; Valente, M.; Veltri, P.; Zamengo, A.; Zaniol, B.; Zanotto, L.; Zaupa, M.; Boilson, D.; Graceffa, J.; Svensson, L.; Schunke, B.; Decamps, H.; Urbani, M.; Kushwah, M.; Chareyre, J.; Singh, M.; Bonicelli, T.; Agarici, G.; Garbuglia, A.; Masiello, A.; Paolucci, F.; Simon, M.; Bailly-Maitre, L.; Bragulat, E.; Gomez, G.; Gutierrez, D.; Mico, G.; Moreno, J.-F.; Pilard, V.; Chakraborty, A.; Baruah, U.; Rotti, C.; Patel, H.; Nagaraju, M. V.; Singh, N. P.; Patel, A.; Dhola, H.; Raval, B.; Fantz, U.; Fröschle, M.; Heinemann, B.; Kraus, W.; Nocentini, R.; Riedl, R.; Schiesko, L.; Wimmer, C.; Wünderlich, D.; Cavenago, M.; Croci, G.; Gorini, G.; Rebai, M.; Muraro, A.; Tardocchi, M.; Hemsworth, R.
2017-08-01
SPIDER is one of two projects of the ITER Neutral Beam Test Facility under construction in Padova, Italy, at the Consorzio RFX premises. It will have a 100 keV beam source with a full-size prototype of the radiofrequency ion source for the ITER neutral beam injector (NBI) and also, similar to the ITER diagnostic neutral beam, it is designed to operate with a pulse length of up to 3600 s, featuring an ITER-like magnetic filter field configuration (for high extraction of negative ions) and caesium oven (for high production of negative ions) layout as well as a wide set of diagnostics. These features will allow a reproduction of the ion source operation in ITER, which cannot be done in any other existing test facility. SPIDER realization is well advanced and the first operation is expected at the beginning of 2018, with the mission of achieving the ITER heating and diagnostic NBI ion source requirements and of improving its performance in terms of reliability and availability. This paper mainly focuses on the preparation of the first SPIDER operations—integration and testing of SPIDER components, completion and implementation of diagnostics and control and formulation of operation and research plan, based on a staged strategy.
Detailed requirements document for the Interactive Financial Management System (IFMS), volume 1
NASA Technical Reports Server (NTRS)
Dodson, D. B.
1975-01-01
The detailed requirements for phase 1 (online fund control, subauthorization accounting, and accounts receivable functional capabilities) of the Interactive Financial Management System (IFMS) are described. This includes information on the following: systems requirements, performance requirements, test requirements, and production implementation. Most of the work is centered on systems requirements, and includes discussions on the following processes: resources authority, allotment, primary work authorization, reimbursable order acceptance, purchase request, obligation, cost accrual, cost distribution, disbursement, subauthorization performance, travel, accounts receivable, payroll, property, edit table maintenance, end-of-year, backup input. Other subjects covered include: external systems interfaces, general inquiries, general report requirements, communication requirements, and miscellaneous. Subjects covered under performance requirements include: response time, processing volumes, system reliability, and accuracy. Under test requirements come test data sources, general test approach, and acceptance criteria. Under production implementation come data base establishment, operational stages, and operational requirements.
Verification study of an emerging fire suppression system
Cournoyer, Michael E.; Waked, R. Ryan; Granzow, Howard N.; ...
2016-01-01
Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation andmore » mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.« less
Verification study of an emerging fire suppression system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael E.; Waked, R. Ryan; Granzow, Howard N.
Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation andmore » mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Wei; DeCroix, David; Sun, Xin
The attrition of particles is a major industrial concern in many fluidization systems as it can have undesired effects on the product quality and on the reliable operation of process equipment. Therefore, to accomodate the screening and selection of catalysts for a specific process in fluidized beds, risers, or cyclone applications, their attrition propensity is usually estimated through jet cup attrition testing, where the test material is subjected to high gas velocities in a jet cup. However, this method is far from perfect despite its popularity, largely due to its inconsistency in different testing set-ups. In order to better understandmore » the jet cup testing results as well as their sensitivity to different operating conditions, a coupled computational fluid dynamic (CFD) - discrete element method (DEM) model has been developed in the current study to investigate the particle attrition in a jet cup and its dependence on various factors, e.g. jet velocity, initial particle size, particle density, and apparatus geometry.« less
Fiber Optic Cable Thermal Preparation to Ensure Stable Operation
NASA Technical Reports Server (NTRS)
Thoames Jr, William J.; Chuska, Rick F.; LaRocca, Frank V.; Switzer, Robert C.; Macmurphy, Shawn L.; Ott, Melanie N.
2008-01-01
Fiber optic cables are widely used in modern systems that must provide stable operation during exposure to changing environmental conditions. For example, a fiber optic cable on a satellite may have to reliably function over a temperature range of -50 C up to 125 C. While the system requirements for a particular application will dictate the exact method by which the fibers should be prepared, this work will examine multiple ruggedized fibers prepared in different fashions and subjected to thermal qualification testing. The data show that if properly conditioned the fiber cables can provide stable operation, but if done incorrectly, they will have large fluctuations in transmission.
Small satellite product assurance
NASA Astrophysics Data System (ADS)
Demontlivault, J.; Cadelec, Jacques
1993-01-01
In order to increase the interest in small satellites, their cost must be reduced; reducing product assurance costs induced by quality requirements is a major objective. For a logical approach, small satellites are classified in three main categories: satellites for experimental operations with a short lifetime, operational satellites manufactured in small mass with long lifetime requirements, operational satellites (long lifetime required), of which only a few models are produced. The various requirements as regards the product assurance are examined for each satellite category: general requirements for space approach, reliability, electronic components, materials and processes, quality assurance, documentation, tests, and management. Ideal product assurance system integrates quality teams and engineering teams.
Operational Experience of the Upgraded Cryogenic Systems at the Nscl
NASA Astrophysics Data System (ADS)
McCartney, A. H.; Laumer, H. L.; Jones, S. A.
2010-04-01
The National Superconducting Cyclotron Laboratory (NSCL) is a NSF-supported facility, with additional support from Michigan State University (MSU) for conducting research in nuclear and accelerator science. The facility consists of two superconducting cyclotrons and over fifty individual cryostats, each containing several superconducting magnets that are used in the beam transport system. Beginning in 1999 a major facility upgrade was started. New, larger magnets were added, increasing the total 4.5 K loads, necessitating an increase of the cryogenic capacity. A helium plant (nominal 1750-Watt at 4.5 K) was acquired from the United States Bureau of Mines where it had been operating as a pure liquefier since the early 1980's. It was refurbished for the NSCL with extensive support from the cryogenics group at Thomas Jefferson National Laboratory. The new cryogenic system came online early in 2001. The cold-mass is relatively high in relation to the installed capacity, presenting challenges during cool downs. Reliability over the last five years has been greater than 99%. An overview of the last seven years of operations of our cryogenic systems is presented that includes normal operations, testing of new equipment, noteworthy breakdowns, routine maintenance, and system reliability.
Joint Air-to-Surface Standoff Missile (JASSM)
2015-12-01
6.1.3) All Ops All Ops Joint Critical Ops All Ops All Ops Missile Reliability (KSA) (CPD para 6.2.8) 4th Lot .91 4th Lot .91 IOT &E .80 4th Lot .85 IOT &E...the ORD 303-95-III dated January 20, 2004 Change Explanations None Acronyms and Abbreviations IOT &E - Initial Operational Test and Evaluation KSA... Actuator Control Card, Lots 12 and 4 Systems Engineering Program Support/Program Tooling and Test Equipment, and JASSM-ER Standard Data Protocol (DS
[Evaluation (assessment) of three tests for diagnosis of geohelmints in Colombia].
López, Myriam Consuelo; Moncada, Ligia Inés; Ariza-Araújo, Yoseth; Fernández-Niño, Julián Alfredo; Reyes, Patricia; Nicholls, Rubén Santiago
2013-01-01
Soil-transmitted helminth infections are considered a public health problem in developing countries. The diagnostic tests, both for individual parient diagnosis as for population studies should be evaluated in terms of validity and reliability. To compare the direct examination, the modified Ritchie-Frick method, a Kato-Katz designed by a Brazilian group and one designed by the WHO, for the diagnosis of soil-transmitted helminthes. A diagnostic test reliability study was performed. The same stool sample was analyzed by the same observer using four diagnostic tests. 204 samples were obtained, 194 of those fulfilled the inclusion criteria and were analyzed. The observers did not know the participants' identity neither the other tests results. For the analysis the Kato-Katz (WHO) was considered as the gold standard. For the reliability assessment percent agreement, positive percent agreement, Kappa statistic, and intraclass correlation were performed. The Brazilian Kato-Katz showed a good performance with high sensitivity and specificity for T. trichiura and Hookworm with values of 0.97 and 0.96 respectively, and a high specificity with mild sensitivity for A. lumbricoides (0.95 and 0.79) meanwhile the direct examination and the Ritche-Frick method showed a performance between mild and poor. The differences were higher for hookworm and Trichiuris trichiura than for Ascaris lumbricoides. The Brazilian Kato Katz test could be implemented, but further studies are needed to correlate its operative capacity with its feasibility, availability and cost.
Makris, Susan L.; Raffaele, Kathleen; Allen, Sandra; Bowers, Wayne J.; Hass, Ulla; Alleva, Enrico; Calamandrei, Gemma; Sheets, Larry; Amcoff, Patric; Delrue, Nathalie; Crofton, Kevin M.
2009-01-01
Objective We conducted a review of the history and performance of developmental neurotoxicity (DNT) testing in support of the finalization and implementation of Organisation of Economic Co-operation and Development (OECD) DNT test guideline 426 (TG 426). Information sources and analysis In this review we summarize extensive scientific efforts that form the foundation for this testing paradigm, including basic neurotoxicology research, interlaboratory collaborative studies, expert workshops, and validation studies, and we address the relevance, applicability, and use of the DNT study in risk assessment. Conclusions The OECD DNT guideline represents the best available science for assessing the potential for DNT in human health risk assessment, and data generated with this protocol are relevant and reliable for the assessment of these end points. The test methods used have been subjected to an extensive history of international validation, peer review, and evaluation, which is contained in the public record. The reproducibility, reliability, and sensitivity of these methods have been demonstrated, using a wide variety of test substances, in accordance with OECD guidance on the validation and international acceptance of new or updated test methods for hazard characterization. Multiple independent, expert scientific peer reviews affirm these conclusions. PMID:19165382
Negahban, Hossein; Mohtasebi, Elham; Goharpey, Shahin
2015-01-01
The aim of this methodological study was to cross-culturally translate the Shoulder Activity Scale (SAS) into the Persian and determine its clinimetric properties including reliability, validity, and responsiveness in patients with shoulder disorders. Persian version of the SAS was obtained after standard forward-backward translation. Three questionnaires were completed by the respondents: SAS, shoulder pain and disability index (SPADI), and Short-Form 36 Health Survey (SF-36). The patients completed the SAS, 1 week after the first visit to evaluate the test-retest reliability. Construct validity was evaluated by examining the associations between the scores on the SAS and the scores obtained from the SPADI, SF-36, and age of the patients. To assess responsiveness, data were collected in the first visit and then again after 4 weeks physiotherapy intervention. Test-retest reliability and internal consistency were assessed using Intra-class Correlation Coefficient (ICC) and Cronbach's alpha, respectively. To evaluate construct validity, Spearman's rank correlation was used. The ability of the SAS to detect changes was evaluated by the receiver-operating characteristics method. No problem or language difficulties were reported during translation process. Test-retest reliability of the SAS was excellent with an ICC of 0.98. Also, the marginal Cronbach's alpha level of 0.64 was obtained. The correlation between the SAS and the SPADI was low, proving divergent validity, whereas the correlations between the SAS and the SF-36/age were moderate proving convergent validity. A marginally acceptable responsiveness was achieved for the Persian SAS. The study provides some evidences to support the test-retest reliability, internal consistency, construct validity, and responsiveness of the Persian version of the SAS in patients with shoulder disorders. Therefore, it seems that this instrument is a useful measure of shoulder activity level in research setting and clinical practice. The shoulder activity scale (SAS) is a reliable, valid, and responsive measure of shoulder activity level in Persian-speaking patients with different shoulder disorders. The results on clinimetric properties of the Persian SAS are comparable with its original, English version. Persian version of the SAS can be used in "clinical" and "research" settings of patients with shoulder disorders.
NASA Technical Reports Server (NTRS)
Belcastro, Celeste M.
1989-01-01
Control systems for advanced aircraft, especially those with relaxed static stability, will be critical to flight and will, therefore, have very high reliability specifications which must be met for adverse as well as nominal operating conditions. Adverse conditions can result from electromagnetic disturbances caused by lightning, high energy radio frequency transmitters, and nuclear electromagnetic pulses. Tools and techniques must be developed to verify the integrity of the control system in adverse operating conditions. The most difficult and illusive perturbations to computer based control systems caused by an electromagnetic environment (EME) are functional error modes that involve no component damage. These error modes are collectively known as upset, can occur simultaneously in all of the channels of a redundant control system, and are software dependent. A methodology is presented for performing upset tests on a multichannel control system and considerations are discussed for the design of upset tests to be conducted in the lab on fault tolerant control systems operating in a closed loop with a simulated plant.
Chapter 15: Reliability of Wind Turbines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheng, Shuangwen; O'Connor, Ryan
The global wind industry has witnessed exciting developments in recent years. The future will be even brighter with further reductions in capital and operation and maintenance costs, which can be accomplished with improved turbine reliability, especially when turbines are installed offshore. One opportunity for the industry to improve wind turbine reliability is through the exploration of reliability engineering life data analysis based on readily available data or maintenance records collected at typical wind plants. If adopted and conducted appropriately, these analyses can quickly save operation and maintenance costs in a potentially impactful manner. This chapter discusses wind turbine reliability bymore » highlighting the methodology of reliability engineering life data analysis. It first briefly discusses fundamentals for wind turbine reliability and the current industry status. Then, the reliability engineering method for life analysis, including data collection, model development, and forecasting, is presented in detail and illustrated through two case studies. The chapter concludes with some remarks on potential opportunities to improve wind turbine reliability. An owner and operator's perspective is taken and mechanical components are used to exemplify the potential benefits of reliability engineering analysis to improve wind turbine reliability and availability.« less
Reliability Demonstration Approach for Advanced Stirling Radioisotope Generator
NASA Technical Reports Server (NTRS)
Ha, CHuong; Zampino, Edward; Penswick, Barry; Spronz, Michael
2010-01-01
Developed for future space missions as a high-efficiency power system, the Advanced Stirling Radioisotope Generator (ASRG) has a design life requirement of 14 yr in space following a potential storage of 3 yr after fueling. In general, the demonstration of long-life dynamic systems remains difficult in part due to the perception that the wearout of moving parts cannot be minimized, and associated failures are unpredictable. This paper shows a combination of systematic analytical methods, extensive experience gained from technology development, and well-planned tests can be used to ensure a high level reliability of ASRG. With this approach, all potential risks from each life phase of the system are evaluated and the mitigation adequately addressed. This paper also provides a summary of important test results obtained to date for ASRG and the planned effort for system-level extended operation.
Operational present status and reliability analysis of the upgraded EAST cryogenic system
NASA Astrophysics Data System (ADS)
Zhou, Z. W.; Y Zhang, Q.; Lu, X. F.; Hu, L. B.; Zhu, P.
2017-12-01
Since the first commissioning in 2005, the cryogenic system for EAST (Experimental Advanced Superconducting Tokamak) has been cooled down and warmed up for thirteen experimental campaigns. In order to promote the refrigeration efficiencies and reliability, the EAST cryogenic system was upgraded gradually with new helium screw compressors and new dynamic gas bearing helium turbine expanders with eddy current brake to improve the original poor mechanical and operational performance from 2012 to 2015. Then the totally upgraded cryogenic system was put into operation in the eleventh cool-down experiment, and has been operated for the latest several experimental campaigns. The upgraded system has successfully coped with various normal operational modes during cool-down and 4.5 K steady-state operation under pulsed heat load from the tokamak as well as the abnormal fault modes including turbines protection stop. In this paper, the upgraded EAST cryogenic system including its functional analysis and new cryogenic control networks will be presented in detail. Also, its operational present status in the latest cool-down experiments will be presented and the system reliability will be analyzed, which shows a high reliability and low fault rate after upgrade. In the end, some future necessary work to meet the higher reliability requirement for future uninterrupted long-term experimental operation will also be proposed.
Validation of the Brazilian Portuguese Version of Geriatric Anxiety Inventory--GAI-BR.
Massena, Patrícia Nitschke; de Araújo, Narahyana Bom; Pachana, Nancy; Laks, Jerson; de Pádua, Analuiza Camozzato
2015-07-01
The Geriatric Anxiety Inventory (GAI) is a recently developed scale aiming to evaluate symptoms of anxiety in later life. This 20-item scale uses dichotomous answers highlighting non-somatic anxiety complaints of elderly people. The present study aimed to evaluate the psychometric properties of the Brazilian Portuguese version GAI (GAI-BR) in a sample from community and outpatient psychogeriatric clinic. A mixed convenience sample of 72 subjects was recruited for answering the research protocol. The interview procedures were structured with questionnaires about sociodemographic data, clinical health status, anxiety, and depression previously validated instruments, Mini-Mental State Examination, Mini International Neuropsychiatric Interview, and GAI-BR. Twenty-two percent of the sample were interviewed twice for test-retest reliability. For internal consistency analyses, the Cronbach's α test was applied. The Spearman correlation test was applied to evaluate the test-retest GAI-BR reliability. A ROC (receiver operating characteristic) curve study was made to estimate the GAI-BR area under curve, cut-off points, sensitivity, and specificity for the Generalized Anxiety Disorder diagnosis. The GAI-BR version showed high internal consistency (Cronbach's α = 0.91) and strong and significant test-retest reliability (ρ = 0.85, p < 0.001). It also showed moderate and significant correlation with the Beck Anxiety Inventory (ρ = 0.68, p < 0.001) and the State-Trait Anxiety Inventory (ρ = 0.61, p < 0.001) showing evidence of concurrent validation. The cut-off point of 13 estimated by ROC curve analyses showed sensitivity of 83.3% and specificity of 84.6% to detect Generalized Anxiety Disorder (DSM-IV). GAI-BR has demonstrated very good psychometric properties and can be a reliable instrument to measure anxiety in Brazilian elderly people.
Development of modified FT (MFT) process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jinglai Zhou; Zhixin Zhang; Wenjie Shen
1995-12-31
Two-Stage Modified FT (MFT) process has been developed for producing high-octane gasoline from coal-based syngas. The main R&D are focused on the development of catalysts and technologies process. Duration tests were finished in the single-tube reactor, pilot plant (100T/Y), and industrial demonstration plant (2000T/Y). A series of satisfactory results has been obtained in terms of operating reliability of equipments, performance of catalysts, purification of coal - based syngas, optimum operating conditions, properties of gasoline and economics etc. Further scaling - up commercial plant is being considered.
2006-09-01
work-horse for this thesis. He spent hours writing some of the more tedious code, and as much time helping me learn C++ and Linux . He was always there...compared with C++, and the need to use Linux as the operating system, the filter was coded using C++ and KDevelop [28] in SUSE LINUX Professional 9.2 [42...The driving factor for using Linux was the operating system’s ability to access the serial ports in a reliable fashion. Under the original MATLAB® and
Göras, Camilla; Wallentin, Fan Yang; Nilsson, Ulrica; Ehrenberg, Anna
2013-03-19
Tens of millions of patients worldwide suffer from avoidable disabling injuries and death every year. Measuring the safety climate in health care is an important step in improving patient safety. The most commonly used instrument to measure safety climate is the Safety Attitudes Questionnaire (SAQ). The aim of the present study was to establish the validity and reliability of the translated version of the SAQ. The SAQ was translated and adapted to the Swedish context. The survey was then carried out with 374 respondents in the operating room (OR) setting. Data was received from three hospitals, a total of 237 responses. Cronbach's alpha and confirmatory factor analysis (CFA) was used to evaluate the reliability and validity of the instrument. The Cronbach's alpha values for each of the factors of the SAQ ranged between 0.59 and 0.83. The CFA and its goodness-of-fit indices (SRMR 0.055, RMSEA 0.043, CFI 0.98) showed good model fit. Intercorrelations between the factors safety climate, teamwork climate, job satisfaction, perceptions of management, and working conditions showed moderate to high correlation with each other. The factor stress recognition had no significant correlation with teamwork climate, perception of management, or job satisfaction. Therefore, the Swedish translation and psychometric testing of the SAQ (OR version) has good construct validity. However, the reliability analysis suggested that some of the items need further refinement to establish sound internal consistency. As suggested by previous research, the SAQ is potentially a useful tool for evaluating safety climate. However, further psychometric testing is required with larger samples to establish the psychometric properties of the instrument for use in Sweden.
Long-Term Reliability of SiGe/Si HBTs From Accelerated Lifetime Testing
NASA Technical Reports Server (NTRS)
Bhattacharya, Pallab
2001-01-01
Accelerated lifetime tests were performed on double-mesa structure Si(0.7)Ge(0.3)/Si npn heterojunction bipolar transistors, grown by molecular beam epitaxy, in the temperature range of 175 C-275 C. The transistors (with 5x20 sq micron emitter area) have DC current gains approx. 40-50 and f(sub T) and f(sub max) of up to 22 GHz and 25 GHz, respectively. It is found that a gradual degradation in these devices is caused by the recombination enhanced impurity diffusion (REID) of boron atoms from the p-type base region and the associated formation of parasitic energy barriers to electron transport from the emitter to collector layers. This REED has been quantitatively modeled and explained, to the first order of approximation, and the agreement with the measured data is good. The mean time to failure (MTTF) of these devices at room temperature under 1.35 x 10(exp 4) A/sq cm current density operation is estimated from the extrapolation of the Arrhenius plots of device lifetime versus reciprocal temperature. The results of the reliability tests offer valuable feedback for SiGe heterostructure design in order to improve the long-term reliability of the devices and circuits made with them. Hot electron induced degradation of the base-emitter junction was also observed during the accelerated lifetime testing. In order to improve the HBT reliability endangered by the hot electrons, deuterium sintered techniques have been proposed. The preliminary results from this study show that a deuterium-sintered HBT is, indeed, more resistant to hot-electron induced base-emitter junction degradation.
Bota, Simona; Paternostro, Rafael; Etschmaier, Alexandra; Schwarzer, Remy; Salzl, Petra; Mandorfer, Mattias; Kienbacher, Christian; Ferlitsch, Monika; Reiberger, Thomas; Trauner, Michael; Peck-Radosavljevic, Markus; Ferlitsch, Arnulf
2015-09-01
Liver stiffness values assessed with 2-D shear wave elastography (SWE), transient elastography (TE) and simple serologic tests were compared with respect to non-invasive assessment in a cohort of 127 consecutive patients with chronic liver diseases. The rate of reliable liver stiffness measurements was significantly higher with 2-D SWE than with TE: 99.2% versus 74.8%, p < 0.0001 (different reliability criteria used, according to current recommendations). In univariate analysis, liver stiffness measured with 2-D SWE correlated best with fibrosis stage estimated with TE (r = 0.699, p < 0.0001), followed by Forns score (r = 0.534, p < 0.0001) and King's score (r = 0.512, p < 0.0001). However, in multivariate analysis, only 2-D SWE-measured values remained correlated with fibrosis stage (p < 0.0001). The optimal 2-D SWE cutoff values for predicting significant fibrosis were 8.03 kPa for fibrosis stage ≥2 (area under the receiver operating characteristic curve = 0.832) and 13.1 kPa for fibrosis stage 4 (area under the receiver operating characteristic curve = 0.915), respectively. In conclusion, 2-D SWE can be used to obtain reliable liver stiffness measurements in almost all patients and performs very well in predicting the presence of liver cirrhosis. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Chanani, Ankit; Adhikari, Haridas Das
2017-01-01
Differential diagnosis of periapical cysts and granulomas is required as their treatment modalities are different. The aim of this study was to evaluate the efficacy of cone beam computed tomography (CBCT) in the differential diagnosis of periapical cysts from granulomas. A single-centered observational study was carried out in the Department of Conservative Dentistry and Endodontics, Dr. R. Ahmed Dental College and Hospital, using CBCT and dental operating microscope. Forty-five lesions were analyzed using CBCT scans. One evaluator analyzed each CBCT scan for the presence of the following six characteristic radiological features: cyst like-location, shape, periphery, internal structure, effect on the surrounding structures, and cortical plate perforation. Another independent evaluator analyzed the CBCT scans. This process was repeated after 6 months, and inter- and intrarater reliability of CBCT diagnoses was evaluated. Periapical surgeries were performed and tissue samples were obtained for histopathological analysis. To evaluate the efficacy, CBCT diagnoses were compared with histopathological diagnoses, and six receiver operating characteristic (ROC) curve analyses were conducted. ROC curve, Cronbach's alpha (α) test, and Cohen Kappa (κ) test were used for statistical analysis. Both inter- and intrarater reliability were excellent (α = 0.94, κ = 0.75 and 0.77, respectively). ROC curve with regard to ≥4 positive findings revealed the highest area under curve (0.66). CBCT is moderately accurate in the differential diagnosis of periapical cysts and granulomas.
Development of a Mars Environmental Control and Life Support System (ECLSS).
NASA Technical Reports Server (NTRS)
Henninger, Donald L.
2016-01-01
ECLS systems for very long-duration human missions to Mars will be designed to operate reliably for many years and will never be returned to Earth. The need for high reliability is driven by unsympathetic abort scenarios. Abort from a Mars mission could be as long as 450 days to return to Earth. Simply put, the goal of an ECLSS is to duplicate the functions the Earth provides in terms of human living and working on our home planet but without the benefit of the Earth's large buffers - the atmospheres, the oceans and land masses. With small buffers a space-based ECLSS must operate as a true dynamic system rather than independent processors taking things from tanks, processing them, and then returning them to product tanks. Key is a development process that allows for a logical sequence of validating successful development (maturation) in a stepwise manner with key performance parameters (KPPs) at each step; especially KPPs for technologies evaluated in a full systems context with human crews on Earth and on space platforms such as the ISS. This paper will explore the implications of such an approach to ECLSS development and the roles of ground and space-based testing necessary to develop a highly reliable life support system for long duration human exploration missions. Historical development and testing of ECLS systems from Mercury to the International Space Station (ISS) will be reviewed. Current work as well as recommendations for future work will be described.