Sample records for operator hand dose

  1. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    PubMed

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  2. The reduction methods of operator's radiation dose for portable dental X-ray machines.

    PubMed

    Cho, Jeong-Yeon; Han, Won-Jeong

    2012-08-01

    This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

  3. Efficacy of a radiation absorbing shield in reducing dose to the interventionalist during peripheral endovascular procedures: a single centre pilot study.

    PubMed

    Power, S; Mirza, M; Thakorlal, A; Ganai, B; Gavagan, L D; Given, M F; Lee, M J

    2015-06-01

    This prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures. A commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used to measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated. TLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142). Initial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator's body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.

  4. Exposure of the surgeon's hands to radiation during hand surgery procedures.

    PubMed

    Żyluk, Andrzej; Puchalski, Piotr; Szlosser, Zbigniew; Dec, Paweł; Chrąchol, Joanna

    2014-01-01

    The objective of the study was to assess the time of exposure of the surgeon's hands to radiation and calculate of the equivalent dose absorbed during surgery of hand and wrist fractures with C-arm fluoroscope guidance. The necessary data specified by the objective of the study were acquired from operations of 287 patients with fractures of fingers, metacarpals, wrist bones and distal radius. 218 operations (78%) were percutaneous procedures and 60 (22%) were performed by open method. Data on the time of exposure and dose of radiation were acquired from the display of the fluoroscope, where they were automatically generated. These data were assigned to the individual patient, type of fracture, method of surgery and the operating surgeon. Fixations of distal radial fractures required longer times of radiation exposure (mean 61 sec.) than fractures of the wrist/metacarpals and fingers (38 and 32 sec., respectively), which was associated with absorption of significantly higher equivalent doses. Fixations of distal radial fractures by open method were associated with statistically significantly higher equivalent doses (0.41 mSv) than percutaneous procedures (0.3 mSv). Fixations of wrist and metacarpal bone fractures by open method were associated with lower equivalent doses (0.34 mSv) than percutaneous procedures (0.37 mSv),but the difference was not significant. Fixations of finger fractures by open method were associated with lower equivalent doses (0.13 mSv) than percutaneous procedures (0.24 mSv), the difference being statistically non-significant. Statistically significant differences in exposure time and equivalent doses were noted between 4 surgeons participating in the study, but no definitive relationship was found between these parameters and surgeons' employment time. 1. Hand surgery procedures under fluoroscopic guidance are associated with mild exposure of the surgeons' hands to radiation. 2. The equivalent dose was related to the type of fracture, operative technique and - to some degree - to the time of employment of the surgeon.

  5. Radiation Protection Methods for the Interventionalist’s Hands: Use of an Extension Tube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dixon, Shaheen, E-mail: shaheen7noorani@gmail.com; Schick, Daniel, E-mail: Daniel.Schick@health.qld.gov.au; Harper, John, E-mail: John-Harper@health.qld.gov.au

    2015-04-15

    PurposeCumulative radiation exposure to the hands during certain interventional procedures may be high. It is important to decrease the amount of radiation to the operator due to the possibility of deterministic effects. We performed a pilot study to demonstrate a significant decrease in operator dose when using extension tubing (ET) in combination with shielding and collimation during a simulated percutaneous transhepatic cholangiogram (PTC) procedure.MethodsA whole body, anthropomorphic phantom was used to simulate the patient. A Unfors-Xi Survey detector (to measure scatter) supported by a retort stand and trolley was placed in various positions to simulate the position of hands andmore » eyes/thyroid of an interventionalist. Radiation dose was measured simulating left and right-sided PTC punctures with and without a lead shield, and with and without ET.ResultsRegarding the radiation dose to the hands; the use of an ET reduces dose by 54 % in right-sided PTC punctures without a shield and by 91 % if used in combination with a shield. For left-sided PTC punctures, ET reduces hand dose by 75 %. The use of collimation decreases hand dose by approximately 60 %. The use of shielding reduces dose to the eyes/thyroid by 98 %.ConclusionsThe dose to the hands can be significantly reduced with the appropriate use of a shield, ET, and tight collimation. The use of a shield is paramount to reduce dose to the eyes/thyroid. It is important for interventionalists to adhere to radiation protective practice considering the potential deterministic effects during a lifelong career.« less

  6. Elevated Radiation Exposure Associated With Above Surface Flat Detector Mini C-Arm Use.

    PubMed

    Martin, Dennis P; Chapman, Talia; Williamson, Christopher; Tinsley, Brian; Ilyas, Asif M; Wang, Mark L

    2017-11-01

    This study aims to test the hypothesis that: (1) radiation exposure is increased with the intended use of Flat Surface Image Intensifier (FSII) units above the operative surface compared with the traditional below-table configuration; (2) this differential increases in a dose-dependent manner; and (3) radiation exposure varies with body part and proximity to the radiation source. A surgeon mannequin was seated at a radiolucent hand table, positioned for volar distal radius plating. Thermoluminescent dosimeters measured exposure to the eyes, thyroid, chest, hand, and groin, for 1- and 15-minute trials from a mini C-arm FSII unit positioned above and below the operating surface. Background radiation was measured by control dosimeters placed within the operating theater. At 1-minute of exposure, hand and eye dosages were significantly greater with the flat detector positioned above the table. At 15-minutes of exposure, hand radiation dosage exceeded that of all other anatomic sites with the FSII in both positions. Hand exposure was increased in a dose-dependent manner with the flat detector in either position, whereas groin exposure saw a dose-dependent only with the flat detector beneath the operating table. These findings suggest that the surgeon's hands and eyes may incur greater radiation exposure compared with other body parts, during routine mini C-arm FSII utilization in its intended position above the operating table. The clinical impact of these findings remains unclear, and future long-term radiation safety investigation is warranted. Surgeons should take precautions to protect critical body parts, particularly when using FSII technology above the operating with prolonged exposure time.

  7. Efficacy of a Radiation Absorbing Shield in Reducing Dose to the Interventionalist During Peripheral Endovascular Procedures: A Single Centre Pilot Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Power, S.; Mirza, M.; Thakorlal, A.

    PurposeThis prospective pilot study was undertaken to evaluate the feasibility and effectiveness of using a radiation absorbing shield to reduce operator dose from scatter during lower limb endovascular procedures.Materials and MethodsA commercially available bismuth shield system (RADPAD) was used. Sixty consecutive patients undergoing lower limb angioplasty were included. Thirty procedures were performed without the RADPAD (control group) and thirty with the RADPAD (study group). Two separate methods were used to measure dose to a single operator. Thermoluminescent dosimeter (TLD) badges were used to measure hand, eye, and unshielded body dose. A direct dosimeter with digital readout was also used tomore » measure eye and unshielded body dose. To allow for variation between control and study groups, dose per unit time was calculated.ResultsTLD results demonstrated a significant reduction in median body dose per unit time for the study group compared with controls (p = 0.001), corresponding to a mean dose reduction rate of 65 %. Median eye and hand dose per unit time were also reduced in the study group compared with control group, however, this was not statistically significant (p = 0.081 for eye, p = 0.628 for hand). Direct dosimeter readings also showed statistically significant reduction in median unshielded body dose rate for the study group compared with controls (p = 0.037). Eye dose rate was reduced for the study group but this was not statistically significant (p = 0.142).ConclusionInitial results are encouraging. Use of the shield resulted in a statistically significant reduction in unshielded dose to the operator’s body. Measured dose to the eye and hand of operator were also reduced but did not reach statistical significance in this pilot study.« less

  8. Reducing operator radiation exposure during cardiac resynchronization therapy.

    PubMed

    Brambilla, Marco; Occhetta, Eraldo; Ronconi, Martina; Plebani, Laura; Carriero, Alessandro; Marino, Paolo

    2010-12-01

    To quantify the reduction in equivalent dose at operator's hand that can be achieved by placement of a radiation-absorbing drape (RADPAD) during long-lasting cardiac resynchronization therapy (CRT) procedures. This is a prospective observational study that included 22 consecutive patients with drug-refractory heart failure who underwent implantation of a CRT device. The cases were randomly assigned to Group A (11 cases), performed without RADPAD, and to Group B (11 cases), performed using RADPAD. Dose equivalent at the examiner's hand was measured as H(p)(0.07) and as a time-adjusted H(p)(0.07) rate (mGy/min) with a direct reading dosimeter. The mean fluoroscopy time was 20.8 ± 7.7 min and the mean dose area product (DAP) was 118.6 ± 45.3 Gy cm(2). No significant differences were found between body mass index, fluoroscopy time, and DAP between patients examined with or without RADPAD. The correlation between the fluoroscopy time and the DAP was high (R(2) = 0.94, P < 0.001). Mean dose and dose rate measurement without the RADPAD at the finger and hand were H(p)(0.07) = 1.27 ± 0.47 mGy per procedure and H(p)(0.07) rate = 0.057 ± 0.011 mGy/min, respectively. The dosage was reduced with the RADPAD to H(p)(0.07) = 0.48 ± 0.20 (P < 0.05) and to H(p)(0.07) rate = 0.026 ± 0.008 (P < 0.001), respectively. A mean reduction of 54% in the equivalent dose rate to the operator's hand can be achieved with the use of RADPAD. The use of the RADPAD in CRT devices implantation will make unlikely the necessity of limiting the yearly number of implants for high volume operators.

  9. Dose-response relationship between hand-transmitted vibration and hand-arm vibration syndrome in a tropical environment.

    PubMed

    Su, Anselm Ting; Maeda, Setsuo; Fukumoto, Jin; Darus, Azlan; Hoe, Victor C W; Miyai, Nobuyuki; Isahak, Marzuki; Takemura, Shigeki; Bulgiba, Awang; Yoshimasu, Kouichi; Miyashita, Kazuhisa

    2013-07-01

    The dose-response relationship for hand-transmitted vibration has been investigated extensively in temperate environments. Since the clinical features of hand-arm vibration syndrome (HAVS) differ between the temperate and tropical environment, we conducted this study to investigate the dose-response relationship of HAVS in a tropical environment. A total of 173 male construction, forestry and automobile manufacturing plant workers in Malaysia were recruited into this study between August 2011 and 2012. The participants were interviewed for history of vibration exposure and HAVS symptoms, followed by hand functions evaluation and vibration measurement. Three types of vibration doses-lifetime vibration dose (LVD), total operating time (TOT) and cumulative exposure index (CEI)-were calculated and its log values were regressed against the symptoms of HAVS. The correlation between each vibration exposure dose and the hand function evaluation results was obtained. The adjusted prevalence ratio for finger tingling and numbness was 3.34 (95% CI 1.27 to 8.98) for subjects with lnLVD≥20 ln m(2) s(-4) against those <16 ln m(2) s(-4). Similar dose-response pattern was found for CEI but not for TOT. No subject reported white finger. The prevalence of finger coldness did not increase with any of the vibration doses. Vibrotactile perception thresholds correlated moderately with lnLVD and lnCEI. The dose-response relationship of HAVS in a tropical environment is valid for finger tingling and numbness. The LVD and CEI are more useful than TOT when evaluating the dose-response pattern of a heterogeneous group of vibratory tools workers.

  10. Dosimetric evaluation of the staff working in a PET/CT department

    NASA Astrophysics Data System (ADS)

    Dalianis, K.; Malamitsi, J.; Gogou, L.; Pagou, M.; Efthimiadou, R.; Andreou, J.; Louizï, A.; Georgiou, E.

    2006-12-01

    The dosimetric literature data concerning the medical personnel working in positron emission tomography/computed tomography (PET/CT) departments are limited. Therefore, we measured the radiation dose of the staff working in the first PET/CT department in Greece at the Diagnostic and Therapeutic Center of Athens HYGEIA—Harvard Medical International. As, for the time being, only 2-deoxy-2-[ 18F]fluoro-d-glucose (FDG) PET studies are performed, radiation dose measurements concern those derived from dispensing of the radiopharmaceutical as well as from the patients undergoing FDG-PET imaging. Our aim is to develop more effective protective measures against radionuclide exposure. To estimate the effective dose from external exposure, all seven members of the staff (two nurses, two medical physicists, two technologists, one secretary) had TLD badges worn at the upper pocket of their overall, TLD rings on the right hand and digital dosimeters at their upper side pocket. In addition, isodose curves were measured with thermoluminescence detectors for distances of 20, 50, 70 and 100 cm away from patients who had been injected with 18F-FDG. Dose values of the PET/CT staff were measured with digital detectors, TLD badges and TLD rings over the first 8 months for a total of 160 working days of the department's operation, consisting of a workload of about 10-15 patients/week who received 250-420 MBq of 18F-FDG each. Whole - body collective doses and hand doses for the staff were the following: Nurse #1 received 1.6 mSv as a whole body dose and 2,1 as a hand dose, Nurse #2 received 1.9 and 2.4 mSv respectively. For medical physicist #1 the dose values were 1.45 mSv whole body and 1.7 mSv hand dose, for medical physicist #2 1.67 mSv wholebody dose and 1.55 mSv hand dose and for technologists #1 & #2 the whole body doses were 0.7 and 0.64 mSv respectively. Lastly, the secretary received 0.1 mSv whole body dose. These preliminary data have shown that the dose levels of our PET/CT staff are within acceptable limits.

  11. Dosimetry during intramedullary nailing of the tibia.

    PubMed

    Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George

    2009-10-01

    Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.

  12. Occupational and patient exposure in coronary angiography procedures

    NASA Astrophysics Data System (ADS)

    Sulieman, A.; Alzimami, K.; Gafar, R.; Babikir, E.; Alsafi, K.; Suliman, I. I.

    2014-11-01

    Cardiac catheterization is the gold standard in the diagnosis and management of coronary artery diseases. The objectives of this study were to evaluate the radiation dose of patients and staff during cardiology procedures. Staff was monitored using thermoluminescence dosimeter (TLD) chips for 86 procedures. The mean patient dose was 2813.6 μGy m2 and the mean fluoroscopic time was 4.8 min. The mean radiation doses for cardiologists were 0.9 mGy for the forehead, 0.92 mGy for the thyroid, 1.38 mGy for the chest, 1.28 mGy for the waist and 1.41 mGy for the hand. The mean radiation doses for assistants were 0.72 mGy for the chest, 0.82 mGy for the hand. High patient and staff exposure is due to lack of experience and protective equipment, exacerbated by a high workload. Interventional procedures remain operator dependent; therefore, continuous training is crucial.

  13. The accuracy, precision and sustainability of different techniques for tablet subdivision: breaking by hand and the use of tablet splitters or a kitchen knife.

    PubMed

    van Riet-Nales, Diana A; Doeve, Myrthe E; Nicia, Agnes E; Teerenstra, Steven; Notenboom, Kim; Hekster, Yechiel A; van den Bemt, Bart J F

    2014-05-15

    Tablets are frequently subdivided to lower the dose, to facilitate swallowing by e.g. children or older people or to save costs. Splitting devices are commonly used when hand breaking is difficult or painful. Three techniques for tablet subdivision were investigated: hand breaking, tablet splitter, kitchen knife. A best case drug (paracetamol), tablet (round, flat, uncoated, 500 mg) and operator (24-year student) were applied. Hundred tablets were subdivided by hand and by three devices of each of the following types: Fit & Healthy, Health Care Logistics, Lifetime, PillAid, PillTool, Pilomat tablet splitter; Blokker kitchen knife. The intra and inter device accuracy, precision and sustainability were investigated. The compliance to (adapted) regulatory requirements was investigated also. The accuracy and precision of hand broken tablets was 104/97% resp. 2.8/3.2% (one part per tablet considered; parts right/left side operator). The right/left accuracies of the splitting devices varied between 60 and 133%; the precisions 4.0 and 29.6%. The devices did not deteriorate over 100-fold use. Only hand broken tablets complied with all regulatory requirements. Health care professionals should realize that tablet splitting may result in inaccurate dosing. Authorities should undertake appropriate measures to assure good function of tablet splitters and, where feasible, to reduce the need for their use. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  14. CT Fluoroscopy Shielding: Decreases in Scattered Radiation for the Patient and Operator

    PubMed Central

    Neeman, Ziv; Dromi, Sergio A.; Sarin, Shawn; Wood, Bradford J.

    2008-01-01

    PURPOSE High-radiation exposure occurs during computed tomographic (CT) fluoroscopy. Patient and operator doses during thoracic and abdominal interventional procedures were studied in the present experiment, and a novel shielding device to reduce exposure to the patient and operator was evaluated. MATERIALS AND METHODS With a 16-slice CT scanner in CT fluoroscopy mode (120 kVp, 30 mA), surface dosimetry was performed on adult and pediatric phantoms. The shielding was composed of tungsten antimony in the form of a lightweight polymer sheet. Doses to the patient were measured with and without shielding for thoracic and abdominal procedures. Doses to the operator were recorded with and without phantom, gantry, and table shielding in place. Double-layer lead-free gloves were used by the operator during the procedures. RESULTS Tungsten antimony shielding adjacent to the scan plane resulted in a maximum dose reduction of 92.3% to the patient. Maximum 85.6%, 93.3%, and 85.1% dose reductions were observed for the operator’s torso, gonads, and hands, respectively. The use of double-layer lead-free gloves resulted in a maximum radiation dose reduction of 97%. CONCLUSIONS Methods to reduce exposure during CT fluoroscopy are effective and should be searched for. Significant reduction in radiation doses to the patient and operator can be accomplished with tungsten antimony shielding. PMID:17185699

  15. Dosimetry during intramedullary nailing of the tibia

    PubMed Central

    2009-01-01

    Background Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. Patients and methods 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. Results The mean operation time was 101 (48–240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy·cm2. The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Interpretation Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique. PMID:19916691

  16. Evaluation of inhaled and cutaneous doses of imidacloprid during stapling ornamental plants in tunnels or greenhouses.

    PubMed

    Aprea, Cristina; Lunghini, Liana; Banchi, Bruno; Peruzzi, Antonio; Centi, Letizia; Coppi, Luana; Bogi, Mirella; Marianelli, Enrico; Fantacci, Mariella; Catalano, Pietro; Benvenuti, Alessandra; Miligi, Lucia; Sciarra, Gianfranco

    2009-09-01

    The aim of this research was to assess dermal and respiratory exposure of workers to imidacloprid during manual operations with ornamental plants previously treated in greenhouses or tunnels. A total of 10 female workers, 5 in greenhouses and 5 in tunnels, were monitored for 3 or 5 consecutive days. Actual skin contamination, excluding hands, was evaluated using nine filter paper pads placed directly on the skin. To evaluate the efficacy of protective clothing in reducing occupational exposure we also placed four pads on top of the outer clothing. Hand contamination was evaluated by washing with 95% ethanol. Respiratory exposure was evaluated by personal air sampling. Respiratory dose was calculated on the basis of a lung ventilation of 15 l/min. Absorbed doses were calculated assuming a skin penetration of 10% and a respiratory retention of 100%. Dislodgeable foliar residues (DFRs) were determined during the days of re-entry in order to determine the dermal transfer factor. From the dependence of dermal exposure of hands from DFRs, a mean transfer factor was estimated to be 36.4 cm(2)/h. Imidacloprid was determined by liquid chromatography with selective mass detection and electrospray interface in all matrices analysed. Respiratory dose was 4.1+/-4.0 (0.1-14.3)% and 3.0+/-2.0 (0.6-6.9)% (mean+/-SD (range)) of the total real dose during work in tunnels and greenhouses, respectively. The estimated absorbed doses, 0.29+/-0.45 microg/kg (0.06-2.25 microg/kg) body weight and 0.32+/-0.18 microg/kg (0.07-0.66 microg/kg) body weight (mean+/-SD (range)) in tunnels and in greenhouses, respectively, were less than the acceptable operator exposure level of 0.15 mg/kg body weight and than the acceptable daily intake of 0.05 mg/kg body weight. The hands and exposed skin of all workers were found to be contaminated, indicating that greater precautions, such as daily changing of gloves and clothing, are necessary to reduce skin exposure.

  17. Evaluation of Operator Radioprotection Using a New Injection Device during Vertebroplasty

    PubMed Central

    Nguyen-Kim, L.; Fargeot, C.; Beaussier, H.; Payen, S.; Chiras, J.

    2013-01-01

    Summary This study aimed to evaluate the protection granted by a simple device (X'TENS®, Thiebaud, France) and to provide operators with information on the performance of this new device, which has not yet been assessed. Our assumption is that this device efficiently reduces the radiation dose to the operator. In a prospective clinical study, the radiation dose the operator's hand receives has been assessed using a specific sensor (UNFOR Instrument). Each patient included in the study was to receive at least two injections of cement during the procedure. Exposure was measured with and without the range extender. The data collected were then processed using a Wilcoxon matched pairs test. During 14 interventions, 20 vertebrae were treated with both procedures. Eleven women and three men were included. Seven patients underwent vertebroplasty for metastatic lesions and seven for osteoporotic lesions, bone fractures or vertebral compressions. The average injection time was 1.35 minutes with the device and 1.20 without (p=0.75). The dose to the hand per ml injected was 111.37 vs. 166.91 (p<0.05). Theoretically, the protection granted by the range extender depends on the length of the device. Our results are consistent with the inverse-square law. However, the variations in our results indicate that a proper and rigorous use is mandatory for the device to be effective. Given that radioprotection during fluoroscopy procedures is a frequently raised issue, the need for information for a safer practice increases likewise. PMID:23693040

  18. Evaluation of operator radioprotection using a new injection device during vertebroplasty.

    PubMed

    Nguyen-Kim, L; Fargeot, C; Beaussier, H; Payen, S; Chiras, J

    2013-06-01

    This study aimed to evaluate the protection granted by a simple device (X'TENS(®), Thiebaud, France) and to provide operators with information on the performance of this new device, which has not yet been assessed. Our assumption is that this device efficiently reduces the radiation dose to the operator. In a prospective clinical study, the radiation dose the operator's hand receives has been assessed using a specific sensor (UNFOR Instrument). Each patient included in the study was to receive at least two injections of cement during the procedure. Exposure was measured with and without the range extender. The data collected were then processed using a Wilcoxon matched pairs test. During 14 interventions, 20 vertebrae were treated with both procedures. Eleven women and three men were included. Seven patients underwent vertebroplasty for metastatic lesions and seven for osteoporotic lesions, bone fractures or vertebral compressions. The average injection time was 1.35 minutes with the device and 1.20 without (p=0.75). The dose to the hand per ml injected was 111.37 vs. 166.91 (p<0.05). Theoretically, the protection granted by the range extender depends on the length of the device. Our results are consistent with the inverse-square law. However, the variations in our results indicate that a proper and rigorous use is mandatory for the device to be effective. Given that radioprotection during fluoroscopy procedures is a frequently raised issue, the need for information for a safer practice increases likewise.

  19. MO-DE-BRA-04: Hands-On Fluoroscopy Safety Training with Real-Time Patient and Staff Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanderhoek, M; Bevins, N

    Purpose: Fluoroscopically guided interventions (FGI) are routinely performed across many different hospital departments. However, many involved staff members have minimal training regarding safe and optimal use of fluoroscopy systems. We developed and taught a hands-on fluoroscopy safety class incorporating real-time patient and staff dosimetry in order to promote safer and more optimal use of fluoroscopy during FGI. Methods: The hands-on fluoroscopy safety class is taught in an FGI suite, unique to each department. A patient equivalent phantom is set on the patient table with an ion chamber positioned at the x-ray beam entrance to the phantom. This provides a surrogatemore » measure of patient entrance dose. Multiple solid state dosimeters (RaySafe i2 dosimetry systemTM) are deployed at different distances from the phantom (0.1, 1, 3 meters), which provide surrogate measures of staff dose. Instructors direct participating clinical staff to operate the fluoroscopy system as they view live fluoroscopic images, patient entrance dose, and staff doses in real-time. During class, instructors work with clinical staff to investigate how patient entrance dose, staff doses, and image quality are affected by different parameters, including pulse rate, magnification, collimation, beam angulation, imaging mode, system geometry, distance, and shielding. Results: Real-time dose visualization enables clinical staff to directly see and learn how to optimize their use of their own fluoroscopy system to minimize patient and staff dose, yet maintain sufficient image quality for FGI. As a direct result of the class, multiple hospital departments have implemented changes to their imaging protocols, including reduction of the default fluoroscopy pulse rate and increased use of collimation and lower dose fluoroscopy modes. Conclusion: Hands-on fluoroscopy safety training substantially benefits from real-time patient and staff dosimetry incorporated into the class. Real-time dose display helps clinical staff visualize, internalize, and ultimately utilize the safety techniques learned during the training. RaySafe/Unfors/Fluke lent us a portable version of their RaySafe i2 Dosimetry System for 6 months.« less

  20. OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING FLUOROSCOPICALLY-GUIDED PROCEDURES

    PubMed Central

    Kim, Kwang Pyo; Miller, Donald L.; de Gonzalez, Amy Berrington; Balter, Stephen; Kleinerman, Ruth A.; Ostroumova, Evgenia; Simon, Steven L.; Linet, Martha S.

    2012-01-01

    In the past 30 years, the numbers and types of fluoroscopically-guided (FG) procedures have increased dramatically. The objective of the present study is to provide estimated radiation doses to physician specialists, other than cardiologists, who perform FG procedures. We searched Medline to identify English-language journal articles reporting radiation exposures to these physicians. We then identified several primarily therapeutic FG procedures that met specific criteria: well-defined procedures for which there were at least five published reports of estimated radiation doses to the operator, procedures performed frequently in current medical practice, and inclusion of physicians from multiple medical specialties. These procedures were percutaneous nephrolithotomy (PCNL), vertebroplasty, orthopedic extremity nailing for treatment of fractures, biliary tract procedures, transjugular intrahepatic portosystemic shunt creation (TIPS), head/neck endovascular therapeutic procedures, and endoscopic retrograde cholangiopancreatography (ERCP). We abstracted radiation doses and other associated data, and estimated effective dose to operators. Operators received estimated doses per patient procedure equivalent to doses received by interventional cardiologists. The estimated effective dose per case ranged from 1.7 – 56μSv for PCNL, 0.1 – 101 μSv for vertebroplasty, 2.5 – 88μSv for orthopedic extremity nailing, 2.0 – 46μSv for biliary tract procedures, 2.5 – 74μSv for TIPS, 1.8 – 53μSv for head/neck endovascular therapeutic procedures, and 0.2 – 49μSv for ERCP. Overall, mean operator radiation dose per case measured over personal protective devices at different anatomic sites on the head and body ranged from 19 – 800 (median = 113) μSv at eye level, 6 – 1180 (median = 75)μSv at the neck, and 2 – 1600 (median = 302) μSv at the trunk. Operators’ hands often received greater doses than the eyes, neck or trunk. Large variations in operator doses suggest that optimizing procedure protocols and proper use of protective devices and shields might reduce occupational radiation dose substantially. PMID:22647920

  1. Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms.

    PubMed

    Attigah, Nicolas; Oikonomou, Kyriakos; Hinz, Ulf; Knoch, Thomas; Demirel, Serdar; Verhoeven, Eric; Böckler, Dittmar

    2016-01-01

    The purpose of this study was to evaluate the radiation exposure of vascular surgeons' eye lens and fingers during complex endovascular procedures in modern hybrid operating rooms. Prospective, nonrandomized multicenter study design. One hundred seventy-one consecutive patients (138 male; median age, 72.5 years [interquartile range, 65-77 years]) underwent an endovascular procedure in a hybrid operating room between March 2012 and July 2013 in two vascular centers. The dose-area product (DAP), fluoroscopy time, operating time, and amount of contrast dye were registered prospectively. For radiation dose recordings, single-use dosimeters were attached at eye level and to the ring finger of the hand next to the radiation field of the operator for each endovascular procedure. Dose recordings were evaluated by an independent institution. Before the study, precursory investigations were obtained to simulate the radiation dose to eye lens and fingers with an Alderson phantome (RSD, Long Beach, Calif). Interventions were classified into six treatment categories: endovascular repair of infrarenal abdominal aneurysm (n = 65), thoracic endovascular aortic repair (n = 32), branched endovascular aortic repair for thoracoabdominal aneurysms (n = 17), fenestrated endovascular aortic repair for complex abdominal aortic aneurysm, (n = 25), iliac branched device (n = 8), and peripheral interventions (n = 24). There was a significant correlation in DAP between both lens (P < .01; r = 0.55) and finger (P < .01; r = 0.56) doses. The estimated fluoroscopy time to reach a radiation threshold of 20 mSv/y was 1404.10 minutes (90% confidence limit, 1160, 1650 minutes). According to correlation of the lens dose with the DAP an estimated cumulative DAP of 932,000 mGy/m(2) (90% confidence limit, 822,000, 1,039,000) would be critical for a threshold of 20 mSv/y for the eyes. Radiation protection is a serious issue for vascular surgeons because most complex endovascular procedures are delivering measurable radiation to the eyes. With the correlation of the DAP obtained in standard endovascular procedures a critical threshold of 20 mSv/y to the eyes can be predicted and thus an estimate of a potential harmful exposure to the eyes can be obtained. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  2. Common hand sanitizer may distort readings of breathalyzer tests in the absence of acute intoxication.

    PubMed

    Ali, Syed S; Wilson, Michael P; Castillo, Edward M; Witucki, Peter; Simmons, Todd T; Vilke, Gary M

    2013-02-01

    The use of alcohol-based hand sanitizers has recently become widespread. To the authors' knowledge, no previous study has examined whether application of ethanol-based hand sanitizers by the person operating a common breathalyzer machine will affect the accuracy of the readings. This was a prospective study investigating whether the use of hand sanitizer applied according to manufacturer's recommendations (Group I), applied improperly at standard doses (Group II), or applied improperly at high doses (Group III) had an effect on breathalyzer readings of individuals who had not ingested alcohol. The participants of the prospective study were divided into three groups to assess the effect of hand sanitizer on breathalyzer readings. Group I used one pump (1.5 mL) of hand sanitizer (Purell), allowing the hands to dry per manufacturer's recommendations; Group II used one pump (1.5 mL), without allowing the hands to dry; and Group III used two pumps (3 mL), without allowing the hands to dry. Breathalyzer measures for each group are presented as medians with interquartile ranges (IQR) and ranges. Differences between each sequential group (I vs. II and II vs. III) were assessed using a Mann-Whitney U-test (p < 0.05 significant). There were 25 study participants in each group for a total of 75 participants. The initial breathalyzer readings of all study participants were 0.000 g/dL. The median breathalyzer reading was 0.004 g/dL in Group I (IQR = 0.001 to 0.008 g/dL), 0.051 g/dL in Group II (IQR = 0.043 to 0.064 g/dL), and 0.119 g/dL in Group III (IQR = 0.089 to 0.134 g/dL). Measures between each subsequent group were all statistically different (p < 0.001). The use of common alcohol-based hand sanitizer may cause false-positive readings with a standard hospital breathalyzer when the operator uses the hand sanitizer correctly. The breathalyzer readings are further elevated if more sanitizer is used or if it is not allowed to dry appropriately. © 2013 by the Society for Academic Emergency Medicine.

  3. The effect of work system on the hand exposure of workers in 18F-FDG production centres.

    PubMed

    Wrzesień, Małgorzata

    2018-05-07

    The production of the 18 F isotope-the marker of deoxyglucose ( 18 F-FDG)-the radiopharmaceutical most commonly used in the oncological diagnostic technique of positron emission tomography, requires a cyclotron device. At present, there are nine facilities working in Poland that are equipped with cyclotrons used for producing the short-lived isotopes. The aim of the paper is to determine the hand exposure of workers employed in the two 18 F-FDG production centres taking in to account the production procedures and work system in those facilities. Measurements, which included all professional workers exposed to ionizing radiation that were employed in two facilities, were performed by using high-sensitivity thermoluminescent detectors during the routine activities of the personnel. The work system used at the production centre has an impact on the level of the recorded doses. Among the production procedures performed by the staff, the highest ionizing radiation doses have been received by the staff during the 18 F-FDG quality control. The maximum estimated annual Hp(0.07) for chemists from the quality control department can exceed the annual skin limit dose (500 mSv). The source of lowest doses on the hands are the cyclotron operating procedure and the 18 F-FDG production, provided that these procedures can't be combined with other production procedures.

  4. Inhalational and dermal exposures during spray application of biocides.

    PubMed

    Berger-Preiss, Edith; Boehncke, Andrea; Könnecker, Gustav; Mangelsdorf, Inge; Holthenrich, Dagmar; Koch, Wolfgang

    2005-01-01

    Data on inhalational and potential dermal exposures during spray application of liquid biocidal products were generated. On the one hand, model experiments with different spraying devices using fluorescent tracers were carried out to investigate the influence of parameters relevant to the exposure (e.g. spraying equipment, nozzle size, direction of application). On the other hand, measurements were performed at selected workplaces (during disinfection operations in food and feed areas; pest control operations for private, public and veterinary hygiene; wood protection and antifouling applications) after application of biocidal products such as Empire 20, Responsar SC, Omexan-forte, Actellic, Perma-forte; Fendona SC, Pyrethrum mist; CBM 8, Aldekol Des 03, TAD CID, Basileum, Basilit. The measurements taken in the model rooms demonstrated dependence of the inhalation exposure on the type of spraying device used, in the following order: "spraying with low pressure" < "airless spraying" < "fogging" indicating that the particle diameter of the released spray droplets is the most important parameter. In addition inhalation exposure was lowest when the spraying direction was downward. Also for the potential dermal exposure, the spraying direction was of particular importance: overhead spraying caused the highest contamination of body surfaces. The data of inhalational and potential dermal exposures gained through workplace measurements showed considerable variation. During spraying procedures with low-pressure equipments, dose rates of active substances inhaled by the operators ranged from 7 to 230 microg active substance (a.s.)/h. An increase in inhaled dose rates (6-33 mg a.s./h) was observed after use of high application volumes/time unit during wood protection applications indoors. Spraying in the veterinary sector using medium-pressure sprayers led to inhaled dose rates between 2 and 24mga.s./h. The highest inhaled dose rates were measured during fogging (114 mg a.s./h) and after-high-pressure applications in the antifouling sector (110-300 mg a.s./h). The potential dermal exposure of spray operators was lowest (dose rates from 0.2 to 7 mg a.s./h) in the areas of food and feed disinfection and private and public hygiene during spraying with low-pressure devices. During fogging, wood protection and antifouling applications, high-potential dermal exposures of the operators were determined. Dermal dose rates varied between 100 and 34,000 mg a.s./h.

  5. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals.

    PubMed

    Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh

    2016-10-05

    The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel.

  6. Occupational Radiation Exposure to the Extremities of Medical Staff during Hysterosalpingography and Radionuclide Bone Scan Procedures in Several Nigerian Hospitals

    PubMed Central

    Jibiri, Nnamdi Norbert; Akintunde, Tawakalitu Oluwatoyin; Dambele, Musa Yusuf; Olowookere, Christopher Jimoh

    2016-01-01

    Objective: The practice of regular dose measurement helps to ascertain the level of occupational dose delivered to the staff involved in diagnostic procedures. This study was carried out to evaluate the dose exposed to the hands of radiologists and a radiologic technologist carrying out HSG and radionuclide bone scan examinations in several hospitals in Nigeria. Methods: Radiation doses exposed to the hands of radiologists and a technician carrying out hysterosalpingography (HSG) and bone scan procedures were measured using calibrated thermo-luminescent dosimeters. Five radiologists and a radiologic technologist were included in the study for dose measurement. Results: The study indicates that each radiologist carried out approximately 2 examinations per week with the mean dose ranging between 0.49-0.62 mSv per week, resulting in an annual dose of 191 mSv. Similarly, the occupational dose delivered to both the left and right hands of a radiologic technologist administering 99mTc-methylene diphosphonate (MDP) without cannula and with cannula were 10.68 (720.2) and 13.82 (556.4) mSv per week (and per annum), respectively. It was determined that the left hand of the personnel received higher doses than their right hand. Conclusion: The estimated annual dose during HSG is far below the annual dose limit for deterministic effects, however, it is greater than 10% of the applicable annual dose limit. Hence, routine monitoring is required to ensure adequate protection of the personnel. The total annual dose received during the bone scan exceeds the annual dose limit for both hands, and the dose to either left or right hand is greater than the dose limit of 500 mSv/yr. The radiologists monitored are not expected to incur any deterministic effects during HSG examinations, however, accumulated doses arising from the scattered radiation to the eyes, legs, and neck could be substantial and might lead to certain effects. More staff are required to administer 99mTc-MDP in Nigerian institutions to prevent excessive doses to personnel. PMID:27751973

  7. Is the use of the cervical vertebrae maturation method justified to determine skeletal age? A comparison of radiation dose of two strategies for skeletal age estimation.

    PubMed

    Patcas, Raphael; Signorelli, Luca; Peltomäki, Timo; Schätzle, Marc

    2013-10-01

    The aim of this study was to assess effective doses of a lateral cephalogram radiograph with and without thyroid shield and compare the differences with the radiation dose of a hand-wrist radiograph. Thermoluminescent dosimeters were placed at 19 different sites in the head and neck of a tissue-equivalent human skull (RANDO phantom). Analogue lateral cephalograms with and without thyroid shield (67 kV, 250 mA, 10 mAs) and hand-wrist radiographs (40 kV, 250 mA, 10 mAs) were obtained. The effective doses were calculated using the 2007 International Commission on Radiological Protection recommendations. The effective dose for conventional lateral cephalogram without a thyroid shield was 5.03 microsieverts (µSv). By applying a thyroid shield to the RANDO phantom, a remarkable dose reduction of 1.73 µSv could be achieved. The effective dose of a conventional hand-wrist radiograph was calculated to be 0.16 µSv. Adding the effective dose of the hand-wrist radiograph to the effective dose of the lateral cephalogram with thyroid shield resulted in a cumulative effective dose of 3.46 µSv. Without thyroid shield, the effective dose of a lateral cephalogram was approximately 1.5-fold increased than the cumulative effective dose of a hand-wrist radiograph and a lateral cephalogram with thyroid shield. Thyroid is an organ that is very sensitive to radiation exposure. Its shielding will significantly reduce the effective dose. An additional hand-wrist radiograph, involving no vulnerable tissues, however, causes very little radiation risk. In accordance with the ALARA (As Low As Reasonably Achievable) principle, if an evaluation of skeletal age is indicated, an additional hand-wrist radiograph seems much more justifiable than removing the thyroid shield.

  8. Risk of ionising radiation to trainee orthopaedic surgeons.

    PubMed

    Khan, Ishrat A; Kamalasekaran, Senthil; Fazal, M Ali

    2012-02-01

    We undertook this study to determine the amount of scattered radiation received by the primary surgeon, assistant and patient during dynamic hip screw fixation for proximal femoral fractures. Data was collected from fifty patients. Five registrars were included as operating surgeon and four senior house officers as assistant surgeon. Radiation was monitored by thermo luminescent dosimeters placed on the surgeon and assistant. The approximate distance of surgeon and assistant from the operative site was measured. A dosimeter on the unaffected hip of patients measured the radiation to the patient. The results show that the surgeon's dominant hand receives the highest dose of radiation and radiation exposure is dependent on the experience of the operator. Our study concludes that exposure to radiation during this procedure is well below the toxic levels; however greater awareness is needed for harmful effects of exposure to long term low dose radiation.

  9. A comprehensive dose assessment of irradiated hand by iridium-192 source in industrial radiography.

    PubMed

    Hosseini Pooya, S M; Dashtipour, M R; Paydar, R; Mianji, F; Pourshahab, B

    2017-09-01

    Among the various incidents in industrial radiography, inadvertent handling of sources by hands is one of the most frequent incidents in which some parts of the hands may be locally exposed to high doses. An accurate assessment of extremity dose assists medical doctors in selecting appropriate treatments, preventing the injury expansion in the region. In this study, a phantom was designed to simulate a fisted hand of a radiographer when the worker holds a radioactive source in their hands. The local doses were measured using implanted TLDs in the phantom at different distances from a source. Furthermore, skin dose distribution was measured by Gaf-chromic films in the palm region of the phantom. The reliability of the measurements has been studied via analytical as well as Monte-Carlo simulation methods. The results showed that the new phantom design can be used reliably in extremity dose assessments, particularly at the points next to the source.

  10. Methamphetamine residue dermal transfer efficiencies from household surfaces.

    PubMed

    Van Dyke, Mike; Martyny, John W; Serrano, Kate A

    2014-01-01

    Methamphetamine contamination from illegal production operations poses a potential health concern for emergency responders, child protective services, law enforcement, and children living in contaminated structures. The objective of this study was to evaluate dermal transfer efficiencies of methamphetamine from contaminated household surfaces. These transfer efficiencies are lacking for methamphetamine, and would be beneficial for use in exposure models. Surfaces were contaminated using a simulated smoking method in a stainless steel chamber. Household surfaces were carpet, painted drywall, and linoleum. Dermal transfer efficiencies were obtained using cotton gloves for two hand conditions, dry or saliva moistened (wet). In addition, three contact scenarios were evaluated for both hand conditions: one, two, or three contacts with contaminated surfaces. Dermal transfer efficiencies were calculated for both hand conditions and used as inputs in a Stochastic Human Exposure and Dose Simulation model (SHEDS-Multimedia, Office of Research and Development, United States Environmental Protection Agency, Research Triangle Park, N.C.). Results of this study showed that average dermal transfer efficiencies of methamphetamine ranged from 11% for dry hands to 26% for wet hands. There was a significantly higher wet transfer as compared to dry transfer for all surfaces. For wet hands, dermal transfer depended on surface type with higher transfer from carpet and linoleum as compared to drywall. Based on our estimates of dermal transfer efficiency, a surface contamination clearance level of 1.5 μg/100 cm(2) may not ensure absorbed doses remain below the level associated with adverse health effects in all cases. Additional dermal transfer studies should be performed using skin surrogates that may better predict actual skin transfer.

  11. Influence of spray nozzle shape upon atomization process

    NASA Astrophysics Data System (ADS)

    Beniuga, Marius; Mihai, Ioan

    2016-12-01

    The atomization process is affected by a number of operating parameters (pressure, viscosity, temperature, etc.) [1-6] and the adopted constructive solution. In this article are compared parameters of atomized liquid jet with two nozzles that have different lifespan, one being new and the other one out. The last statement shows that the second nozzle was monitored as time of operation on the one hand and on the other hand, two dimensional nozzles have been analyzed using laser profilometry. To compare the experimental parameters was carried an experimental stand to change the period and pulse width in injecting liquid through two nozzles. Atomized liquid jets were photographed and filmed quickly. Images obtained were analyzed using a Matlab code that allowed to determine a number of parameters that characterize an atomized jet. Knowing the conditions and operating parameters of atomized jet, will establish a new wastewater nozzle block of parameter values that can be implemented in controller that provides dosing of the liquid injected. Experimental measurements to observe the myriad forms of atomized droplets to a wide range of operating conditions, realized using the electronic control module.

  12. Radiation exposure to the eye lens of orthopaedic surgeons during various orthopaedic procedures.

    PubMed

    Romanova, K; Vassileva, J; Alyakov, M

    2015-07-01

    The aim of the present study was to assess the radiation dose to the eye lens of orthopaedic surgeons during various orthopaedic procedures and to make efforts to ensure that radiation protection is optimised. The study was performed for Fractura femoris and Fractura cruris procedures performed in orthopaedic operating theatres, as well as for fractures of wrist, ankle and hand/shoulder performed in the emergency trauma room. The highest mean value of the eye lens dose of 47.2 μSv and higher mean fluoroscopy time of 3 min, as well as the corresponding highest maximum values of 77.1 μSv and 5.0 min were observed for the Fractura femoris procedure performed with the Biplanar 500e fluoroscopy systems. At a normal workload, the estimated mean annual dose values do not exceed the annual occupational dose limit for the lens of eye, but at a heavy workload in the department, this dose limit could be achieved or exceeded. The use of protective lead glasses is recommended as they could reduce the radiation exposure of the lens of the eye. The phantom measurements demonstrated that the use of half-dose mode could additionally reduce dose to the operator's eye lens. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shull, D.

    This report documents the initial feasibility tests performed using a commercial acoustic emission instrument for the purpose of detecting beetles in Department of Energy 9975 shipping packages. The device selected for this testing was a commercial handheld instrument and probe developed for the detection of termites, weevils, beetles and other insect infestations in wooden structures, trees, plants and soil. The results of two rounds of testing are presented. The first tests were performed by the vendor using only the hand-held instrument’s indications and real-time operator analysis of the audio signal content. The second tests included hands-free positioning of the instrumentmore » probe and post-collection analysis of the recorded audio signal content including audio background comparisons. The test results indicate that the system is promising for detecting the presence of drugstore beetles, however, additional work would be needed to improve the ease of detection and to automate the signal processing to eliminate the need for human interpretation. Mechanisms for hands-free positioning of the probe and audio background discrimination are also necessary for reliable detection and to reduce potential operator dose in radiation environments.« less

  14. Variability in hand-arm vibration during grinding operations.

    PubMed

    Liljelind, Ingrid; Wahlström, Jens; Nilsson, Leif; Toomingas, Allan; Burström, Lage

    2011-04-01

    Measurements of exposure to vibrations from hand-held tools are often conducted on a single occasion. However, repeated measurements may be crucial for estimating the actual dose with good precision. In addition, knowledge of determinants of exposure could be used to improve working conditions. The aim of this study was to assess hand-arm vibration (HAV) exposure during different grinding operations, in order to obtain estimates of the variance components and to evaluate the effect of work postures. Ten experienced operators used two compressed air-driven angle grinders of the same make in a simulated work task at a workplace. One part of the study consisted of using a grinder while assuming two different working postures: at a standard work bench (low) and on a wall with arms elevated and the work area adjusted to each operator's height (high). The workers repeated the task three times. In another part of the study, investigating the wheel wear, for each grinder, the operators used two new grinding wheels and with each wheel the operator performed two consecutive 1-min grinding tasks. Both grinding tasks were conducted on weld puddles of mild steel on a piece of mild steel. Measurements were taken according to ISO-standard 5349 [the equivalent hand-arm-weighted acceleration (m s(-2)) averaged over 1 min]. Mixed- and random-effects models were used to investigate the influence of the fixed variables and to estimate variance components. The equivalent hand-arm-weighted acceleration assessed when the task was performed on the bench and at the wall was 3.2 and 3.3 m s(-2), respectively. In the mixed-effects model, work posture was not a significant variable. The variables 'operator' and 'grinder' together explained only 12% of the exposure variability and 'grinding wheel' explained 47%; the residual variability of 41% remained unexplained. When the effect of grinding wheel wear was investigated in the random-effects model, 37% of the variability was associated with the wheel while minimal variability was associated with the operator or the grinder and 37% was unexplained. The interaction effect of grinder and operator explained 18% of the variability. In the wheel wear test, the equivalent hand-arm-weighted accelerations for Grinder 1 during the first and second grinding minutes were 3.4 and 2.9 m s(-2), respectively, and for Grinder 2, they were 3.1 and 2.9 m s(-2), respectively. For Grinder 1, the equivalent hand-arm-weighted acceleration during the first grinding minute was significantly higher (P = 0.04) than during the second minute. Work posture during grinding operations does not appear to affect the level of HAV. Grinding wheels explained much of the variability in this study, but almost 40% of the variance remained unexplained. The considerable variability in the equivalent hand-arm-weighted acceleration has an impact on the risk assessment at both the group and the individual level.

  15. Will X-ray Safety Glasses Become Mandatory for Radiological Vascular Interventions?

    PubMed

    Thomas, Rohit Philip; Grau, Mathias; Eldergash, Osama; Kowald, Tobias; Schnabel, Johannes; Szczechowicz, Marcin; Chavan, Ajay

    2018-07-01

    The annual permissible radiation ocular lens dose has been reduced to 20 millisieverts (mSv) in the current European directive 2013/59/Euratom. The aim of this study was to evaluate the personal radiation dose for vascular interventions with special focus on ocular lens dose. From May 2016 to October 2016, the personal radiation doses of two interventionists and four technicians were prospectively recorded during 206 vascular interventions. The position of personnel, intervention type and fluoroscopy time were recorded. Parameters evaluated were total body dose measured by film dosimeter, hand dose measured by ring thermoluminescent dosimeter (TLD) and ocular lens dose measured by TLD placed in front of the safety glasses. Linear regression analysis was used to estimate the dose at 2 and 5 years. The ocular lens dose, hand and total body dose of the two interventionists were 11/5, 56/47 and 0.6 mSv each, respectively. The estimated 5-year ocular dose was 113.08 mSv (95% CI 38.2-187.97)/40.95 (95% CI 16.9-64.7). Similarly, hand dose was 608.4 mSv (95% CI 442.78-774.38)/514.47 (95% CI 329.83-699.10) and body dose 6.07 mSv (95% CI 4.70-8.22)/5.12 (95% CI 3.65-6.59), respectively. Amongst four technicians, only the first assistant showed recordings of 0.3 mSv body dose, 2 mSv ocular lens dose and 5 mSv hand dose. The yearly ocular lens dose, particularly for interventionists dealing with complex interventions, could cross the permitted yearly limit set by the new Euratom directive. Therefore, X-ray safety glasses would become mandatory for complex radiological vascular interventions. Level III, non-randomized controlled cohort/follow-up study.

  16. Vibration-induced multifocal neuropathy in forestry workers: electrophysiological findings in relation to vibration exposure and finger circulation.

    PubMed

    Bovenzi, M; Giannini, F; Rossi, S

    2000-11-01

    To investigate neural conduction in the upper limbs of symptomatic forestry workers with and without exposure to hand-transmitted vibration. A further aim was to assess the possible relationships between vibration exposure, nerve conduction and finger circulation in the forestry workers who used chain saws. A detailed neurophysiological investigation was performed on the upper extremities of 20 chain saw workers, 20 forestry operators with heavy manual work but without vibration exposure, and 20 healthy male controls. All subjects were screened to exclude polyneuropathy. Measurements of sensory and motor nerve conduction (velocity and amplitude) were obtained bilaterally from the median, ulnar and radial nerves. To assess peripheral vascular function, the forestry workers underwent a cold test with plethysmographic measurement of finger systolic blood pressure (FSBP). In the chain saw operators, vibration exposure was evaluated according to the International Standard ISO 5349. Indices of daily vibration exposure and lifetime cumulative vibration dose were estimated for each chain saw operator. Sensory nerve conduction in several segments of the median and radial nerves was significantly reduced in the chain saw operators compared with that in the workers doing heavy manual work and the controls. The neurophysiological pattern more frequently observed in the chain saw operators was a multifocal nerve conduction impairment to several neural segments with predominant involvement of sensory rather than motor fibres. Sensory nerve conduction velocities in the hands of the chain saw operators were inversely related to both daily and lifetime cumulative vibration exposures. In the vibration-exposed forestry workers, neither were sensori-motor complaints associated with vascular symptoms (finger whiteness) nor were electrophysiological data related to cold-induced changes in FSBP. Exposure to hand-transmitted vibration, in addition to ergonomic stress factors, can contribute to peripheral nerve disorders occurring in forestry workers who operate chain saws. The findings of this study suggest the existence of an exposure-effect relationship for vibration-induced neuropathy. Different underlying mechanisms are likely to be involved in the pathogenesis of the neurological and vascular components of the hand-arm vibration syndrome.

  17. Induced radioactivity in the forward shielding and semiconductor tracker of the ATLAS detector.

    PubMed

    Bĕdajánek, I; Linhart, V; Stekl, I; Pospísil, S; Kolros, A; Kovalenko, V

    2005-01-01

    The radioactivity induced in the forward shielding, copper collimator and semiconductor tracker modules of the ATLAS detector has been studied. The ATLAS detector is a long-term experiment which, during operation, will require to have service and access to all of its parts and components. The radioactivity induced in the forward shielding was calculated by Monte Carlo methods based on GEANT3 software tool. The results show that the equivalent dose rates on the outer surface of the forward shielding are very low (at most 0.038 microSv h(-1)). On the other hand, the equivalent dose rates are significantly higher on the inner surface of the forward shielding (up to 661 microSv h(-1)) and, especially, at the copper collimator close to the beampipe (up to 60 mSv h(-1)). The radioactivity induced in the semiconductor tracker modules was studied experimentally. The module was activated by neutrons in a training nuclear reactor and the delayed gamma ray spectra were measured. From these measurements, the equivalent dose rate on the surface of the semiconductor tracker module was estimated to be < 100 microSv h(-1) after 100 d of Large Hadron Collider (LHC) operation and 10 d of cooling.

  18. Hand rub dose needed for a single disinfection varies according to product: a bias in benchmarking using indirect hand hygiene indicator.

    PubMed

    Girard, Raphaële; Aupee, Martine; Erb, Martine; Bettinger, Anne; Jouve, Alice

    2012-12-01

    The 3ml volume currently used as the hand hygiene (HH) measure has been explored as the pertinent dose for an indirect indicator of HH compliance. A multicenter study was conducted in order to ascertain the required dose using different products. The average contact duration before drying was measured and compared with references. Effective hand coverage had to include the whole hand and the wrist. Two durations were chosen as points of reference: 30s, as given by guidelines, and the duration validated by the European standard EN 1500. Each product was to be tested, using standardized procedures, by three nosocomial infection prevention teams, for three different doses (3, 2 and 1.5ml). Data from 27 products and 1706 tests were analyzed. Depending on the product, the dose needed to ensure a 30-s contact duration in 75% of tests ranging from 2ml to more than 3ml, and to ensure a contact duration exceeding the EN 1500 times in 75% of tests ranging from 1.5ml to more than 3ml. The aftermath interpretation is the following: if different products are used, the volume utilized does not give an unbiased estimation of the HH compliance. Other compliance evaluation methods remain necessary for efficient benchmarking. Copyright © 2012 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  19. Cone beam computed tomography in implant dentistry: a systematic review focusing on guidelines, indications, and radiation dose risks.

    PubMed

    Bornstein, Michael M; Scarfe, William C; Vaughn, Vida M; Jacobs, Reinhilde

    2014-01-01

    The aim of the paper is to identify, review, analyze, and summarize available evidence in three areas on the use of cross-sectional imaging, specifically maxillofacial cone beam computed tomography (CBCT) in pre- and postoperative dental implant therapy: (1) Available clinical use guidelines, (2) indications and contraindications for use, and (3) assessment of associated radiation dose risk. Three focused questions were developed to address the aims. A systematic literature review was performed using a PICO-based search strategy based on MeSH key words specific to each focused question of English-language publications indexed in the MEDLINE database retrospectively from October 31, 2012. These results were supplemented by a hand search and gray literature search. Twelve publications were identified providing guidelines for the use of cross-sectional radiography, particularly CBCT imaging, for the pre- and/or postoperative assessment of potential dental implant sites. The publications discovered by the PICO strategy (43 articles), hand (12), and gray literature searches (1) for the second focus question regarding indications and contraindications for CBCT use in implant dentistry were either cohort or case-controlled studies. For the third question on the assessment of associated radiation dose risk, a total of 22 articles were included. Publication characteristics and themes were summarized in tabular format. The reported indications for CBCT use in implant dentistry vary from preoperative analysis regarding specific anatomic considerations, site development using grafts, and computer-assisted treatment planning to postoperative evaluation focusing on complications due to damage of neurovascular structures. Effective doses for different CBCT devices exhibit a wide range with the lowest dose being almost 100 times less than the highest dose. Significant dose reduction can be achieved by adjusting operating parameters, including exposure factors and reducing the field of view (FOV) to the actual region of interest.

  20. 49 CFR 218.105 - Additional operational requirements for hand-operated main track switches.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Additional operational requirements for hand... hand-operated main track switches. (a) Each railroad shall adopt and comply with an operating rule... the requirements of this section. (b) Designating switch position. The normal position of a hand...

  1. Monte Carlo Assessments of Absorbed Doses to the Hands of Radiopharmaceutical Workers Due to Photon Emitters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilas, Dan; Eckerman, Keith F; Karagiannis, Harriet

    This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters that are used to show compliance with applicable regulations may overestimate or underestimate radiation doses to the skin depending on the nature of the particular procedure and the radionuclide being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations of realistic configurations typical for workers handling radiopharmaceuticals weremore » performedfor a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from dosimeter readings when dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.« less

  2. Dose Assessments to the Hands of Radiopharmaceutical Workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ilas, Dan; Eckerman, Keith F; Sherbini, Sami

    This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters may overestimate or underestimate the radiation doses to the skin that are used to show compliance with applicable regulations depending on the nature of the particular procedure and the radioisotope being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations on realistic configurations typical for workers handling radiopharmaceuticalsmore » were performed for a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from the dosimeters' readings when the dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.« less

  3. Effectiveness of pelvic lead blanket to reduce the doses to eye lens and hands of interventional cardiologists and assistant nurses.

    PubMed

    Grabowicz, W; Domienik-Andrzejewska, J; Masiarek, K; Górnik, T; Grycewicz, T; Brodecki, M; Lubiński, A

    2017-09-01

    The aim of the present study is to analyse quantitatively the potential reduction of doses to the eye lens and the hands of an operator and a nurse by the use of a pelvic lead blanket during coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures. Thermoluminescent dosimeters were used to assess dose levels to the left eye lens and fingers on both hands of both physician and nurses during single procedures performed with or without the lead blanket. The measurements were carried out at one medical centre and include dosimetric data from 100 procedures. Additional measurements including physician's and patient's doses were made on phantoms in the laboratory. In order to determine the reduction potential of the lead blanket, the doses normalized to DAP (Dose-Area Product) corresponding to the same position of dosimeter were compared against each other for both procedure categories (with and without protection). There was no statistically significant decrease observed in physicians' and nurses' eye lens doses, nor in doses normalized to DAP due to the use of the lead pelvic shield in clinic. However, some trend in reducing the eye lens doses by this shield can be observed. Regarding finger doses, the differences are statistically significant but only for physicians. The mean DAP-normalised doses to the eye lens and left and right finger of physicians, in the presence of a ceiling-suspended transparent lead shield, were 2.24e-5 ± 1.41e-5 mSv/μGym 2 , 2.31e-4 ± 1.21e-4 mSv/μGym 2 , and 2.60e-5 ± 1.57e-5 mSv/μGym 2 for standard procedures performed without the lead blanket, and 1.77e-5 ± 1.17e-5 mSv/μGym 2 , 1.70e-4 ± 1.01e-4 mSv/μGym 2 , and 1.86e-5 ± 1.13e-5 mSv/μGym 2 for procedures performed with it. A comparison of the results from the laboratory and the clinic shows that they are consistent regarding the eye lens, while for fingers it suggests that the dose reduction properties of the lead shield are related to the physician's work technique and both patient and lead blanket sizes or its positioning. The highest degree of reduction is observed for cranial and caudal projections together with the use of a patient-adjustable lead blanket; about a 2-fold decrease in finger doses is expected for optimum conditions. However, the laboratory measurements suggest that the use of lead blanket might slightly increase the patient dose, but only when specific projections are constantly used. This limitation should be considered by cardiologists during clinical work if this protection is used. In the light of the presented results, the ceiling-suspended transparent lead shield and the lead glasses seem to be the preferred way to reduce the doses to the eye lens, compared to the lead blanket.

  4. Radiation hardness study of semi-insulating GaAs detectors against 5 MeV electrons

    NASA Astrophysics Data System (ADS)

    Šagátová, A.; Zaťko, B.; Nečas, V.; Sedlačková, K.; Boháček, P.; Fülöp, M.; Pavlovič, M.

    2018-01-01

    A radiation hardness study of Semi-Insulating (SI) GaAs detectors against 5 MeV electrons is described in this paper. The influence of two parameters, the accumulative absorbed dose (from 1 to 200 kGy) and the applied dose rate (20, 40 or 80 kGy/h), on detector spectrometric properties were studied. The accumulative dose has influenced all evaluated spectrometric properties and also negatively affected the detector CCE (Charge Collection Efficiency). We have observed its systematic reduction from an initial 79% before irradiation down to about 51% at maximum dose of 200 kGy. Relative energy resolution was also influenced by electron irradiation. Its degradation was obvious in the range of doses from 24 up to a maximum dose of 200 kGy, where an increase from 19% up to 31% at 200 V reverse voltage was noticed. On the other hand, a global increase of detection efficiency with accumulative absorbed dose was observed for all samples. Concerning the actual detector degradation we can assume that the tested SI GaAs detectors will be able to operate up to a dose of 300 kGy at least, when irradiated by 5 MeV electrons. The second investigated parameter of irradiation, the dose rate of chosen ranges, did not greatly alter the spectrometric properties of studied detectors.

  5. SEE induced in SRAM operating in a superconducting electron linear accelerator environment

    NASA Astrophysics Data System (ADS)

    Makowski, D.; Mukherjee, Bhaskar; Grecki, M.; Simrock, Stefan

    2005-02-01

    Strong fields of bremsstrahlung photons and photoneutrons are produced during the operation of high-energy electron linacs. Therefore, a mixed gamma and neutron radiation field dominates the accelerators environment. The gamma radiation induced Total Ionizing Dose (TID) effect manifests the long-term deterioration of the electronic devices operating in accelerator environment. On the other hand, the neutron radiation is responsible for Single Event Effects (SEE) and may cause a temporal loss of functionality of electronic systems. This phenomenon is known as Single Event Upset (SEU). The neutron dose (KERMA) was used to scale the neutron induced SEU in the SRAM chips. Hence, in order to estimate the neutron KERMA conversion factor for Silicon (Si), dedicated calibration experiments using an Americium-Beryllium (241Am/Be) neutron standard source was carried out. Single Event Upset (SEU) influences the short-term operation of SRAM compared to the gamma induced TID effect. We are at present investigating the feasibility of an SRAM based real-time beam-loss monitor for high-energy accelerators utilizing the SEU caused by fast neutrons. This paper highlights the effects of gamma and neutron radiations on Static Random Access Memory (SRAM), placed at selected locations near the Superconducting Linear Accelerator driving the Vacuum UV Free Electron Laser (VUVFEL) of DESY.

  6. A prospective cohort study of exposure-response relationship for vibration-induced white finger.

    PubMed

    Bovenzi, M

    2010-01-01

    To investigate prospectively the relation between vibration-induced white finger (VWF) and measures of cumulative (lifetime) exposure to hand-transmitted vibration (HTV). Two hundred and forty-nine HTV workers and 138 control men of the same companies participated in a 3-year follow-up study. The diagnosis of VWF (Raynaud's phenomenon in the controls) was based on the medical history, the administration of colour charts and the results of a cold test. Tool vibration magnitudes were expressed as root-mean-square (r.m.s.) acceleration, frequency-weighted according to international standard ISO 5349-1 and also unweighted over the frequency range 6.3-1250 Hz. From the vibration magnitudes and exposure durations, alternative measures of cumulative vibration dose were calculated for each HTV worker, according to the expression: dose = Sigmaa(i)(m)t(i), where a(i) is the acceleration magnitude on tool i, t(i) is the lifetime exposure duration (hours) for tool i, and m = 0, 1, 2 or 4. The incidence of VWF varied from 5 to 6% in the HTV workers versus 0 to 1.5% for Raynaud's phenomenon in the controls. After adjusting for potential confounders, measures of cumulative vibration dose derived from total operating hours and high powers of unweighted acceleration (ie, , with m>1) gave better predictions of the occurrence of VWF than dose measures calculated from frequency-weighted acceleration (ie, ). These findings were observed in the entire sample of HTV workers, in those with no VWF at the initial investigation, and in those with normal cold test results at baseline. This prospective cohort study suggests that measures of cumulative vibration doses constructed from unweighted r.m.s. acceleration perform better for the prediction of VWF than dose measures calculated according to the recommendations of current standards. These findings should contribute to the improvement of the ISO frequency weighting for evaluating the severity of hand-transmitted vibration.

  7. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  8. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  9. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  10. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  11. 49 CFR 236.410 - Locking, hand-operated switch; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Locking, hand-operated switch; requirements. 236... Traffic Control Systems Standards § 236.410 Locking, hand-operated switch; requirements. (a) Each hand-operated switch in main track shall be locked either electrically or mechanically in normal position...

  12. TU-D-201-07: Severity Indication in High Dose Rate Brachytherapy Emergency Response Procedure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, K; Rustad, F

    Purpose: Understanding the corresponding dose to different staff during the High Dose Rate (HDR) Brachytherapy emergency response procedure could help to develop a strategy in efficiency and effective action. In this study, the variation and risk analysis methodology was developed to simulation the HDR emergency response procedure based on severity indicator. Methods: A GammaMedplus iX HDR unit from Varian Medical System was used for this simulation. The emergency response procedure was decomposed based on risk management methods. Severity indexes were used to identify the impact of a risk occurrence on the step including dose to patient and dose to operationmore » staff by varying the time, HDR source activity, distance from the source to patient and staff and the actions. These actions in 7 steps were to press the interrupt button, press emergency shutoff switch, press emergency button on the afterloader keypad, turn emergency hand-crank, remove applicator from the patient, disconnect transfer tube and move afterloader from the patient, and execute emergency surgical recovery. Results: Given the accumulated time in second at the assumed 7 steps were 15, 5, 30, 15, 180, 120, 1800, and the dose rate of HDR source is 10 Ci, the accumulated dose in cGy to patient at 1cm distance were 188, 250, 625, 813, 3063, 4563 and 27063, and the accumulated exposure in rem to operator at outside the vault, 1m and 10cm distance were 0.0, 0.0, 0.1, 0.1, 22.6, 37.6 and 262.6. The variation was determined by the operators in action at different time and distance from the HDR source. Conclusion: The time and dose were estimated for a HDR unit emergency response procedure. It provided information in making optimal decision during the emergency procedure. Further investigation would be to optimize and standardize the responses for other emergency procedure by time-spatial-dose severity function.« less

  13. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Signal governing movements over hand-operated..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.202 Signal governing movements over hand-operated switch. Signal governing movements over hand-operated switch in the facing direction shall display...

  14. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-operated switch; requirement. 236.528 Section 236.528 Transportation Other Regulations Relating to... Instructions; Roadway § 236.528 Restrictive condition resulting from open hand-operated switch; requirement. When a facing point hand-operated switch is open one-fourth inch or more, a trailing point hand...

  15. 49 CFR 236.6 - Hand-operated switch equipped with switch circuit controller.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Hand-operated switch equipped with switch circuit..., AND APPLIANCES Rules and Instructions: All Systems General § 236.6 Hand-operated switch equipped with switch circuit controller. Hand-operated switch equipped with switch circuit controller connected to the...

  16. 49 CFR 229.87 - Hand-operated switches.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Hand-operated switches. 229.87 Section 229.87....87 Hand-operated switches. All hand-operated switches carrying currents with a potential of more than... outside of the cover. Means shall be provided to show whether the switches are open or closed. Switches...

  17. 49 CFR 236.6 - Hand-operated switch equipped with switch circuit controller.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Hand-operated switch equipped with switch circuit..., AND APPLIANCES Rules and Instructions: All Systems General § 236.6 Hand-operated switch equipped with switch circuit controller. Hand-operated switch equipped with switch circuit controller connected to the...

  18. 49 CFR 236.6 - Hand-operated switch equipped with switch circuit controller.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Hand-operated switch equipped with switch circuit..., AND APPLIANCES Rules and Instructions: All Systems General § 236.6 Hand-operated switch equipped with switch circuit controller. Hand-operated switch equipped with switch circuit controller connected to the...

  19. 49 CFR 229.87 - Hand-operated switches.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Hand-operated switches. 229.87 Section 229.87....87 Hand-operated switches. All hand-operated switches carrying currents with a potential of more than... outside of the cover. Means shall be provided to show whether the switches are open or closed. Switches...

  20. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-operated switch; requirement. 236.528 Section 236.528 Transportation Other Regulations Relating to... Instructions; Roadway § 236.528 Restrictive condition resulting from open hand-operated switch; requirement. When a facing point hand-operated switch is open one-fourth inch or more, a trailing point hand...

  1. 49 CFR 236.6 - Hand-operated switch equipped with switch circuit controller.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Hand-operated switch equipped with switch circuit..., AND APPLIANCES Rules and Instructions: All Systems General § 236.6 Hand-operated switch equipped with switch circuit controller. Hand-operated switch equipped with switch circuit controller connected to the...

  2. 49 CFR 236.528 - Restrictive condition resulting from open hand-operated switch; requirement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-operated switch; requirement. 236.528 Section 236.528 Transportation Other Regulations Relating to... Instructions; Roadway § 236.528 Restrictive condition resulting from open hand-operated switch; requirement. When a facing point hand-operated switch is open one-fourth inch or more, a trailing point hand...

  3. 49 CFR 229.87 - Hand-operated switches.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Hand-operated switches. 229.87 Section 229.87....87 Hand-operated switches. All hand-operated switches carrying currents with a potential of more than... outside of the cover. Means shall be provided to show whether the switches are open or closed. Switches...

  4. 49 CFR 236.6 - Hand-operated switch equipped with switch circuit controller.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Hand-operated switch equipped with switch circuit..., AND APPLIANCES Rules and Instructions: All Systems General § 236.6 Hand-operated switch equipped with switch circuit controller. Hand-operated switch equipped with switch circuit controller connected to the...

  5. 49 CFR 229.87 - Hand-operated switches.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Hand-operated switches. 229.87 Section 229.87....87 Hand-operated switches. All hand-operated switches carrying currents with a potential of more than... outside of the cover. Means shall be provided to show whether the switches are open or closed. Switches...

  6. Hand-foot syndrome in a patient with metastatic lung adenocarcinoma induced by high-dose icotinib: A case report and review of the literature.

    PubMed

    Zheng, Yulong; Fang, Weijia; Xu, Nong

    2012-12-01

    Icotinib is a new oral epidermal growth factor tyrosine kinase inhibitor (EGFR-TKI). The most frequent side-effects of icotinib include rash and diarrhea. Hand-foot syndrome (HFS) induced by EGFR-TKI is rare. The present study describes, for the first time, HFS induced by high-dose icotinib in a 65-year old female with metastatic lung adenocarcinoma. The patient developed HFS during the first week of icotinib treatment with characteristic clinical presentation. HFS regressed after icotinib dose-reduction was initiated. HFS may occur with icotinib, especially when administered in high doses.

  7. The effect of vibration exposure during haul truck operation on grip strength, touch sensation, and balance

    PubMed Central

    Pollard, Jonisha; Porter, William; Mayton, Alan; Xu, Xueyan; Weston, Eric

    2017-01-01

    Falls from mobile equipment are reported at surface mine quarry operations each year in considerable numbers. Research shows that a preponderance of falls occur while getting on/off mobile equipment. Contributing factors to the risk of falls include the usage of ladders, exiting onto a slippery surface, and foot or hand slippage. Balance issues may also contribute to fall risks for mobile equipment operators who are exposed to whole-body vibration (WBV). For this reason, the National Institute for Occupational Safety and Health, Office of Mine Safety and Health Research conducted a study at four participating mine sites with seven haul truck operators. The purpose was to ascertain whether WBV and hand-arm vibration (HAV) exposures for quarry haul truck operators were linked to short-term decreases in performance in relation to postural stability, touch sensation threshold, and grip strength that are of crucial importance when getting on/off the trucks. WBV measures of frequency-weighted RMS accelerations (wRMS) and vibration dose value (VDV), when compared to the ISO/ANSI standards, were mostly below levels identified for the Health Guidance Caution Zone (HGCZ), although there were instances where the levels were within and above the specified Exposure Action Value. Comparably, all mean HAV levels, when compared to the ISO/ANSI standards, were below the HGCZ. For the existing conditions and equipment, no significant correlation could be identified between the WBV, HAV, postural stability, touch sensation threshold, and grip strength measures taken during this study. PMID:28220051

  8. Implementation of a near-zero fluoroscopy approach in interventional electrophysiology: impact of operator experience.

    PubMed

    Wannagat, Severin; Loehr, Lena; Lask, Sebastian; Völk, Katharina; Karaköse, Tamer; Özcelik, Cemil; Mügge, Andreas; Wutzler, Alexander

    2018-04-01

    Catheter ablation is performed under fluoroscopic guidance. Reduction of radiation dose for patients and staff is emphasized by current recommendations. Previous studies have shown that lower operator experience leads to increased radiation dose. On the other hand, less experienced operators may depend even more on fluoroscopic guidance. Our study aimed to evaluate feasibility and efficacy of a non-fluoroscopic approach in different training levels. From January 2017, a near-zero fluoroscopy approach was established in two centers. Four operators (beginner, 1st year fellow, 2nd year fellow, expert) were instructed to perform the complete procedure with the use of a 3-D mapping system without fluoroscopy. A historical cohort that underwent procedures with fluoroscopy use served as control group. Dose area product (DPA), procedure duration, acute procedural success, and complications were compared between the groups and for each operator. Procedures were performed in 157 patients. The first 100 patients underwent procedures with fluoroscopic guidance, the following 57 procedures were performed with the near-zero fluoroscopy approach. The results show a significant reduction in DPA for all operators immediately after implementation of the near-zero fluoroscopy protocol (control 637 ± 611 μGy/m 2 ; beginner 44.1 ± 79.5 μGy/m 2 , p = 0.002; 1st year fellow 24.3 ± 46.4.5 μGy/m 2 , p = 0.001; 2nd year fellow 130.3 ± 233.3 μGy/m 2 , p = 0.003; expert 9.3 ± 37.4 μGy/m 2 , P < 0.001). Procedure duration, acute success, and complications were not significantly different between the groups. Our results show a 90% reduction of DPA shortly after implementation of a near-zero fluoroscopy approach in interventional electrophysiology even in operators in training.

  9. [Radiation exposure of radiologists during angiography: dose measurements outside the lead apron].

    PubMed

    Fischer, H; Przetak, C; Teubert, G; Ewen, K; Mödder, U

    1995-02-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r = 0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dubart, Philippe; Hautot, Felix; Morichi, Massimo

    Good management of dismantling and decontamination (D and D) operations and activities is requiring safety, time saving and perfect radiological knowledge of the contaminated environment as well as optimization for personnel dose and minimization of waste volume. In the same time, Fukushima accident has imposed a stretch to the nuclear measurement operational approach requiring in such emergency situation: fast deployment and intervention, quick analysis and fast scenario definition. AREVA, as return of experience from his activities carried out at Fukushima and D and D sites has developed a novel multi-sensor solution as part of his D and D research, approachmore » and method, a system with real-time 3D photo-realistic spatial radiation distribution cartography of contaminated premises. The system may be hand-held or mounted on a mobile device (robot, drone, e.g). In this paper, we will present our current development based on a SLAM technology (Simultaneous Localization And Mapping) and integrated sensors and detectors allowing simultaneous topographic and radiological (dose rate and/or spectroscopy) data acquisitions. This enabling technology permits 3D gamma activity cartography in real-time. (authors)« less

  11. Simulation of beta radiator handling procedures in nuclear medicine by means of a movable hand phantom.

    PubMed

    Blunck, Ch; Becker, F; Urban, M

    2011-03-01

    In nuclear medicine therapies, people working with beta radiators such as (90)Y may be exposed to non-negligible partial body doses. For radiation protection, it is important to know the characteristics of the radiation field and possible dose exposures at relevant positions in the working area. Besides extensive measurements, simulations can provide these data. For this purpose, a movable hand phantom for Monte Carlo simulations was developed. Specific beta radiator handling scenarios can be modelled interactively with forward kinematics or automatically with an inverse kinematics procedure. As a first investigation, the dose distribution on a medical doctor's hand injecting a (90)Y solution was measured and simulated with the phantom. Modelling was done with the interactive method based on five consecutive frames from a video recorded during the injection. Owing to the use of only one camera, not each detail of the radiation scenario is visible in the video. In spite of systematic uncertainties, the measured and simulated dose values are in good agreement.

  12. 49 CFR 236.819 - Switch, hand operated.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Switch, hand operated. 236.819 Section 236.819 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, hand operated. A non-interlocked switch which can only be operated manually. ...

  13. 49 CFR 236.819 - Switch, hand operated.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Switch, hand operated. 236.819 Section 236.819 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, hand operated. A non-interlocked switch which can only be operated manually. ...

  14. 49 CFR 236.819 - Switch, hand operated.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Switch, hand operated. 236.819 Section 236.819 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, hand operated. A non-interlocked switch which can only be operated manually. ...

  15. 49 CFR 236.819 - Switch, hand operated.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Switch, hand operated. 236.819 Section 236.819 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, hand operated. A non-interlocked switch which can only be operated manually. ...

  16. 49 CFR 236.819 - Switch, hand operated.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Switch, hand operated. 236.819 Section 236.819 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Switch, hand operated. A non-interlocked switch which can only be operated manually. ...

  17. Evaluation of a radiation protection cabin for invasive electrophysiological procedures.

    PubMed

    Dragusin, Octavian; Weerasooriya, Rukshen; Jaïs, Pierre; Hocini, Mélèze; Ector, Joris; Takahashi, Yoshihide; Haïssaguerre, Michel; Bosmans, Hilde; Heidbüchel, Hein

    2007-01-01

    Complex invasive electrophysiological procedures may result in high cumulative operator radiation exposure. Classical protection with lead aprons results in discomfort while radioprotection is still incomplete. This study evaluated the usefulness of a radiation protection cabin (RPC) that completely surrounds the operator. The evaluation was performed independently in two electrophysiology laboratories (E1-Leuven, Belgium; E2-Bordeaux, France), comparing operator radiation exposure using the RPC vs. a 0.5 mm lead-equivalent apron (total of 135 procedures). E1 used thermoluminiscent dosimeters (TLDs) placed at 16 positions in and out of the RPC and nine positions in and out of the apron. E2 used more sensitive electronic personal dosimeters (EPD), placed at waist and neck. The sensitivity thresholds of the TLDs and EPDs were 10-20 microSv and 1-1.5 microSv, respectively. All procedures could be performed unimpeded with the RPC. Median TLD dose values outside protected areas were in the range of 57-452 microSv, whereas doses under the apron or inside the RPC were all at the background radiation level, irrespective of procedure and fluoroscopy duration and of radiation energy delivered. In addition, the RPC was protecting the entire body (except the hands), whereas lead apron protection is incomplete. Also with the more sensitive EPDs, the radiation dose within the RPC was at the sensitivity threshold/background level (1.3+/-0.6 microSv). Again, radiation to the head was significantly lower within the RPC (1.9+/-1.2 microSv) than with the apron (102+/-23 microSv, P<0.001). The use of the RPC allows performing catheter ablation procedures without compromising catheter manipulation, and with negligible radiation exposure for the operator.

  18. Total skin electron irradiation for mycosis fungoides: relationship between acute toxicities and measured dose at different anatomic sites.

    PubMed

    Desai, K R; Pezner, R D; Lipsett, J A; Vora, N L; Luk, K H; Wong, J Y; Chan, S L; Findley, D O; Hill, L R; Marin, L A

    1988-09-01

    From June 1978 to June 1986, 50 patients with primary and recurrent mycosis fungoides were treated with total skin electron irradiation (TSEI), using the Stanford technique, to a total dose of 3600 cGy. TSEI was used alone, or in combination with low dose total body photon irradiation, or MOPP. Thermoluminescent dosimeter (TLD) measurements of the prescribed skin dose were obtained on twenty patients. The dorsum of the foot was 24% higher. The axillae, the bottom, and the arch of the foot were significantly underdosed. Frequencies of acute toxicities noted at 2000 cGy were: Skin, Grade I-II (RTOG) 80%. Partial epilation: scalp, 100%; eyebrows and at eyelashes, 20%. Nail dystrophy, 48%. Edema: hands and feet, 44%. Bullae: dorsum of feet, 8%; hands, 4%; and 3600 cGy: Skin, grade III 22%. Total epilation: scalp, 66%; eyebrows and eyelashes, 56%. Nail loss, 38%. Edema: hands and feet, 76%. Bullae: dorsum of feet, 34%; hands, 12%. Conjunctivitis, 4%. Large bullae, were more significant on the dorsum of the feet. Severe moist desquamation occurred in eight patients who had ulcerated lesions on initial presentation. Three patients were hospitalized due to ulceration and skin infection. All patients completed treatment after a short to moderate break. No patient developed skin necrosis, or corneal ulceration. No correlation exists between dose level, degree and onset of toxicity with previous chemotherapy or TBI. We conclude that the overall toxicity of TSEI is well tolerated.

  19. A Dosimetry Study of Deuterium-Deuterium Neutron Generator-based In Vivo Neutron Activation Analysis.

    PubMed

    Sowers, Daniel; Liu, Yingzi; Mostafaei, Farshad; Blake, Scott; Nie, Linda H

    2015-12-01

    A neutron irradiation cavity for in vivo neutron activation analysis (IVNAA) to detect manganese, aluminum, and other potentially toxic elements in human hand bone has been designed and its dosimetric specifications measured. The neutron source is a customized deuterium-deuterium neutron generator that produces neutrons at 2.45 MeV by the fusion reaction 2H(d, n)3He at a calculated flux of 7 × 10(8) ± 30% s(-1). A moderator/reflector/shielding [5 cm high density polyethylene (HDPE), 5.3 cm graphite and 5.7 cm borated (HDPE)] assembly has been designed and built to maximize the thermal neutron flux inside the hand irradiation cavity and to reduce the extremity dose and effective dose to the human subject. Lead sheets are used to attenuate bremsstrahlung x rays and activation gammas. A Monte Carlo simulation (MCNP6) was used to model the system and calculate extremity dose. The extremity dose was measured with neutron and photon sensitive film badges and Fuji electronic pocket dosimeters (EPD). The neutron ambient dose outside the shielding was measured by Fuji NSN3, and the photon dose was measured by a Bicron MicroREM scintillator. Neutron extremity dose was calculated to be 32.3 mSv using MCNP6 simulations given a 10-min IVNAA measurement of manganese. Measurements by EPD and film badge indicate hand dose to be 31.7 ± 0.8 mSv for neutrons and 4.2 ± 0.2 mSv for photons for 10 min; whole body effective dose was calculated conservatively to be 0.052 mSv. Experimental values closely match values obtained from MCNP6 simulations. These are acceptable doses to apply the technology for a manganese toxicity study in a human population.

  20. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones †

    PubMed Central

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-01-01

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user’s daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy. PMID:27556461

  1. Recognizing the Operating Hand and the Hand-Changing Process for User Interface Adjustment on Smartphones.

    PubMed

    Guo, Hansong; Huang, He; Huang, Liusheng; Sun, Yu-E

    2016-08-20

    As the size of smartphone touchscreens has become larger and larger in recent years, operability with a single hand is getting worse, especially for female users. We envision that user experience can be significantly improved if smartphones are able to recognize the current operating hand, detect the hand-changing process and then adjust the user interfaces subsequently. In this paper, we proposed, implemented and evaluated two novel systems. The first one leverages the user-generated touchscreen traces to recognize the current operating hand, and the second one utilizes the accelerometer and gyroscope data of all kinds of activities in the user's daily life to detect the hand-changing process. These two systems are based on two supervised classifiers constructed from a series of refined touchscreen trace, accelerometer and gyroscope features. As opposed to existing solutions that all require users to select the current operating hand or confirm the hand-changing process manually, our systems follow much more convenient and practical methods and allow users to change the operating hand frequently without any harm to the user experience. We conduct extensive experiments on Samsung Galaxy S4 smartphones, and the evaluation results demonstrate that our proposed systems can recognize the current operating hand and detect the hand-changing process with 94.1% and 93.9% precision and 94.1% and 93.7% True Positive Rates (TPR) respectively, when deciding with a single touchscreen trace or accelerometer-gyroscope data segment, and the False Positive Rates (FPR) are as low as 2.6% and 0.7% accordingly. These two systems can either work completely independently and achieve pretty high accuracies or work jointly to further improve the recognition accuracy.

  2. Advanced dexterous manipulation for IED defeat : report on the feasibility of using the ShadowHand for remote operations.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, Robert J.

    2011-01-01

    Improvised Explosive Device (IED) defeat (IEDD) operations can involve intricate operations that exceed the current capabilities of the grippers on board current bombsquad robots. The Shadow Dexterous Hand from the Shadow Robot Company or 'ShadowHand' for short (www.shadowrobot.com) is the first commercially available robot hand that realistically replicates the motion, degrees-of-freedom and dimensions of a human hand (Figure 1). In this study we evaluate the potential for the ShadowHand to perform potential IED defeat tasks on a mobile platform.

  3. Pisiform excision for pisotriquetral instability and arthritis.

    PubMed

    Campion, Heather; Goad, Andrea; Rayan, Ghazi; Porembski, Margaret

    2014-07-01

    To evaluate wrist strength and kinematics after pisiform excision and preservation of its soft tissue confluence for pisotriquetral instability and arthritis. We evaluated 12 patients, (14 wrists) subjectively and objectively an average of 7.5 years after pisiform excision. Three additional patients were interviewed by phone. Subjective evaluation included inquiry about pain and satisfaction with the treatment. Objective testing included measuring wrist flexion and extension range of motion, grip strength, and static and dynamic flexion and ulnar deviation strengths of the operative hand compared with the nonsurgical normal hand. Four patients had concomitant ulnar nerve decompression at the wrist. All patients were satisfied with the outcome. Wrist flexion averaged 99% and wrist extension averaged 95% of the nonsurgical hand. Mean grip strength of the operative hand was 90% of the nonsurgical hand. Mean static flexion strength of the operative hand was 94% of the nonsurgical hand, whereas mean dynamic flexion strength was 113%. Mean static ulnar deviation strength of the operative hand was 87% of the nonsurgical hand. The mean dynamic ulnar deviation strength of the operative hand was 103% of the nonsurgical hand. Soft tissue confluence-preserving pisiform excision relieved pain and retained wrist motion and static and dynamic strength. Associated ulnar nerve compression was a confounding factor that may have affected outcomes. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Thermoluminescent dosimetry in rotary-dual technique of the total skin electron irradiation.

    PubMed

    Piotrowski, T; Fundowicz, D; Pawlaczyk, M; Malicki, J

    2003-01-01

    The aim of the study was to discuss the results of thermoluminescent dosimetry (TLD) in rotary-dual technique of the total skin electron irradiation (TSEI RD), to confirm beam calibration and monitor unit calculations and to provide data for making clinical decisions. Between May 2001 and April 2002, in 3 cases of mycosis fungoides, 736 dosimetric checks were performed in 34 points at the skin. CaF2:MnTLD-400 cubes (1/8"x1/8"x0.015") were used for in vivo dosimetry. Doses were computed and analyzed for all locations. Percent of described dose and SD for the following localizations from 34 points were: anterior abdomen (reference point) 100+/-6%, upper back 100+/-8%, right calf 98+/-10%, left foot (mid dorsum) 97+/-8%, posterior neck 93+/-6%, right hand (mid dorsum) 78+/-10%, hand fingers 57+/-10%, top of right shoulder 56+/-14%, left groin 35+/-20%, perineum 22+/-17%. The correlations between patient's height and measured doses were sufficient for the following localizations: scalp (top rear), occiput, elbows, hand fingers and hands (mid dorsum). The correlations between obesity index and measured doses were sufficient for the following localizations: shoulders and lateral neck, groins, and perineum. Dosimetric checks at the reference point confirm that our beam calibration technique and monitor unit calculation are accurate. TLD shows that for some parts of the skin such as shoulder, hands and perineum boost fields were required. The correlations with obesity index and height for several sites suggest that boost fields must be customized for each patient.

  5. Use of the Kelly Decontamination System for the cleanup of the auxiliary and fuel-handling buildings at TMI-2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoyt, K.R.; Pavelek, M.D. II

    1987-01-01

    Following the accident at Three Mile Island Unit 2 (TMI-2) substantial areas in the auxiliary and fuel-handling buildings were contaminated. Overflowing sumps backed up floor drains and contaminated a substantial portion of the 282-ft elevation floor. In addition, contamination was spread into the overheads when the nitrogen purge system, which had become internally contaminated, was relieved of overpressure. Operating experience with the Kelly Decontamination System has been exceptional. The system has been defined as a tool of the trade for labor personnel to operate as part of their duties. A detailed training program was provided by the Kelly Division ofmore » Container Products Corporation for the engineers who then trained labor personnel in the operation of the equipment. There were very few problems with personnel on the equipment for routine decontamination operations. The Kelly Decontamination System has proven to be a dose and cost-effective alternative to hands-on decontamination techniques at TMI-2 and should have wide application for large-scale decontamination operations.« less

  6. Impact of a flattening filter free linear accelerator on structural shielding design.

    PubMed

    Jank, Julia; Kragl, Gabriele; Georg, Dietmar

    2014-03-01

    The present study aimed to assess the effects of a flattening filter free medical accelerator on structural shielding demands of a treatment vault of a medical linear accelerator. We tried to answer the question, to what extent the required thickness of the shielding barriers can be reduced if instead of the standard flattened photon beams unflattened ones are used. We chose both an experimental as well as a theoretical approach. On the one hand we measured photon dose rates at protected places outside the treatment room and compared the obtained results for flattened and unflattened beams. On the other hand we complied with international guidelines for adequate treatment vault design and calculated the shielding barriers according to the therein given specifications. Measurements were performed with an Elekta Precise™ linac providing nominal photon energies of 6 and 10 MV. This machine underwent already earlier some modifications in order to be able to operate both with and without a flattening filter. Photon dose rates were measured with a LB133-1 dose rate meter manufactured by Berthold. To calculate the thickness of shielding barriers we referred to the Austrian standard ÖNORM S 5216 and to the US American NCRP Report No. 151. We determined a substantial photon dose rate reduction for all measurement points and photon energies. For unflattened 6 MV beams a reduction factor ranging from 1.4 to 1.8 was identified. The corresponding values for unflattened 10 MV beams were 2.1 and 3.2. The performed shielding calculations indicated the same tendency: For all relevant radiation components we found a reduction in shielding thickness when unflattened beams were used. The required thickness of primary barriers was reduced up to 8.0%, the thickness of secondary barriers up to 11.4%, respectively. For an adequate dimensioning of treatment vault shielding barriers it is by no means irrelevant if the accommodated linac operates with or without a flattening filter. The lower consumption of shielding space and material for new treatment vaults housing a FFF machine may reduce building costs, whereas for existing vaults one might benefit in terms of increased weekly workload. Also a more frequent use of monitor unit intense treatment techniques as well as aiming at reduced occupational exposure for staff is conceivable. Copyright © 2013. Published by Elsevier GmbH.

  7. Man-equivalent telepresence through four fingered human-like hand system

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.

    1992-01-01

    The author describes a newly developed mechanical hand system. The robot hand is in human-like configuration with a thumb and three fingers, a palm, a wrist, and the forearm in which the hand and wrist actuators are located. Each finger and the wrist has its own active electromechanical compliance system, allowing the joint drive trains to be stiffened or loosened. This mechanism imitates the human muscle dual function of positioner and stiffness controller. This is essential for soft grappling operations. The hand-wrist assembly has 16 finger joints, three wrist joints, and five compliance mechanisms for a total of 24 degrees of freedom. The strength of the hand is roughly half that of the human hand and its size is comparable to a male hand. The hand is controlled through an exoskeleton glove controller that the operator wears. The glove provides the man-machine interface in telemanipulation control mode: it senses the operator's inputs to guide the mechanical hand in hybrid position and force control. The hand system is intended for dexterous manipulations in structured environments. Typical applications will include work in hostile environment such as space operations and nuclear power plants.

  8. 49 CFR 218.103 - Hand-operated switches, including crossover switches.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Hand-operated switches, including crossover switches. 218.103 Section 218.103 Transportation Other Regulations Relating to Transportation (Continued... Equipment, Switches, and Fixed Derails § 218.103 Hand-operated switches, including crossover switches. (a)(1...

  9. 49 CFR 218.103 - Hand-operated switches, including crossover switches.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Hand-operated switches, including crossover switches. 218.103 Section 218.103 Transportation Other Regulations Relating to Transportation (Continued... Equipment, Switches, and Fixed Derails § 218.103 Hand-operated switches, including crossover switches. (a)(1...

  10. 49 CFR 218.103 - Hand-operated switches, including crossover switches.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Hand-operated switches, including crossover switches. 218.103 Section 218.103 Transportation Other Regulations Relating to Transportation (Continued... Equipment, Switches, and Fixed Derails § 218.103 Hand-operated switches, including crossover switches. (a)(1...

  11. 49 CFR 218.103 - Hand-operated switches, including crossover switches.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Hand-operated switches, including crossover switches. 218.103 Section 218.103 Transportation Other Regulations Relating to Transportation (Continued... Equipment, Switches, and Fixed Derails § 218.103 Hand-operated switches, including crossover switches. (a)(1...

  12. 49 CFR 218.103 - Hand-operated switches, including crossover switches.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Hand-operated switches, including crossover switches. 218.103 Section 218.103 Transportation Other Regulations Relating to Transportation (Continued... Equipment, Switches, and Fixed Derails § 218.103 Hand-operated switches, including crossover switches. (a)(1...

  13. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock on hand-operated switch; control...) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING..., AND APPLIANCES Automatic Block Signal Systems Standards § 236.207 Electric lock on hand-operated...

  14. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Block Signal Systems Standards § 236.207 Electric lock on hand-operated... 49 Transportation 4 2011-10-01 2011-10-01 false Electric lock on hand-operated switch; control...

  15. 49 CFR 236.314 - Electric lock for hand-operated switch or derail.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock for hand-operated switch or derail...) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING..., AND APPLIANCES Interlocking Standards § 236.314 Electric lock for hand-operated switch or derail...

  16. Pharmacokinetics and safety of imiquimod 5% cream in the treatment of actinic keratoses of the face, scalp, or hands and arms.

    PubMed

    Harrison, Lester I; Skinner, Shari L; Marbury, Thomas C; Owens, Mary L; Kurup, Sarala; McKane, Scott; Greene, Robert J

    2004-06-01

    The safety and efficacy of imiquimod 5% cream is being evaluated for the treatment of dysplastic lesions of the epidermis (actinic keratoses, AK). The objective of this clinical study was to describe the pharmacokinetics and safety of topical imiquimod during multiple dosing of AK subjects. A total of 58 adult subjects with 5 to 20 AK lesions at the treatment site applied imiquimod cream three times per week for up to 16 weeks as follows: 12 males and 11 females applied 12.5 mg imiquimod to the face; 11 males applied 25 mg to the entire balding area of the scalp; and 12 males and 12 females applied 75 mg to both hands and forearms. Pharmacokinetics and safety were assessed after the first and last doses, as well as biweekly. Imiquimod and its metabolites were measured in the serum and urine using sensitive liquid chromatography/mass spectrometry methods. Less than 0.6% of the applied doses was recovered in the urine of all subjects. Serum imiquimod levels were low, reflecting minimal dermal absorption, and increased with dose, although not proportionally. Peak levels at the end of dosing were 0.1, 0.2, and 1.6 ng/ml for the face, scalp, and hands/arms groups, respectively. A two- to fourfold accumulation was seen at the end of dosing. Local application site reactions were the most common adverse event, reported by approximately 50% of the subjects in each treatment group. The small number of systemic adverse events, including 'flu-like symptoms, were mostly mild and did not show a dose response. Thus, minimal systemic absorption and good safety margins for topical imiquimod were seen in AK subjects with doses as high as 75 mg three times per week for 16 weeks.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arentsen, L; Lopater, Z; Dusenbery, K

    Purpose: Duputren’s contracture (DC) is a benign disease characterized by abnormal thickening of the fascial surfaces of the hands or feet causing curling of the surface, functional impairment, weakness, and pain. The purpose of the investigation is to describe the radiation treatment approaches, compare these techniques, and discuss the potential side effects and complications of these techniques. Methods: Early stage DC has been treated with 120 kVp X rays but also with high-energy electrons or photons. High-energy electrons have been the radiation of choice but severe contracture of the hand makes it difficult to produce a plan with acceptable dosemore » uniformity. High-energy photons can overcome this difficulty either by directing a beam onto the palmer or back of the surface of the hand, including bolus to maximize the surface dose. We calculated the dose to the bone for the 120 kVp treatment using published %DD data and mass energy absorption coefficients for bone and muscle. Results: The dose to underlying bone from megavoltage photons and electrons is essentially the same, but dose to the bone for using 120 kVp can be 4–5 times greater due to the photoelectric effect. For the 30 Gy dose deliver using this technique, the dose to the bone could be 84–105 Gy after taking the penetration of the beam into account. After radiotherapy, there is often decreased osteoblastic activity and vascular fibrosis that leads to osteitis, atrophy, and decreased metabolic bone activity. Incidence of fractures occurs routinely above 60 Gy with higher doses potentially leading to higher incidences of bone complications. Conclusion: Radiation therapy for DC using low-energy X rays can deliver a prohibitively high dose to the underlying bone potentially leading to severe bone complications.« less

  18. TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, J; Chan, F; Newman, B

    2014-06-15

    Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze themore » scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.« less

  19. Precision IORT - Image guided intraoperative radiation therapy (igIORT) using online treatment planning including tissue heterogeneity correction.

    PubMed

    Schneider, Frank; Bludau, Frederic; Clausen, Sven; Fleckenstein, Jens; Obertacke, Udo; Wenz, Frederik

    2017-05-01

    To the present date, IORT has been eye and hand guided without treatment planning and tissue heterogeneity correction. This limits the precision of the application and the precise documentation of the location and the deposited dose in the tissue. Here we present a set-up where we use image guidance by intraoperative cone beam computed tomography (CBCT) for precise online Monte Carlo treatment planning including tissue heterogeneity correction. An IORT was performed during balloon kyphoplasty using a dedicated Needle Applicator. An intraoperative CBCT was registered with a pre-op CT. Treatment planning was performed in Radiance using a hybrid Monte Carlo algorithm simulating dose in homogeneous (MCwater) and heterogeneous medium (MChet). Dose distributions on CBCT and pre-op CT were compared with each other. Spinal cord and the metastasis doses were evaluated. The MCwater calculations showed a spherical dose distribution as expected. The minimum target dose for the MChet simulations on pre-op CT was increased by 40% while the maximum spinal cord dose was decreased by 35%. Due to the artefacts on the CBCT the comparison between MChet simulations on CBCT and pre-op CT showed differences up to 50% in dose. igIORT and online treatment planning improves the accuracy of IORT. However, the current set-up is limited by CT artefacts. Fusing an intraoperative CBCT with a pre-op CT allows the combination of an accurate dose calculation with the knowledge of the correct source/applicator position. This method can be also used for pre-operative treatment planning followed by image guided surgery. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. A compact in vivo neutron activation analysis system to quantify manganese in human hand bone

    NASA Astrophysics Data System (ADS)

    Liu, Yingzi

    As an urgent issue of correlating cumulative manganese (Mn) exposure to neurotoxicity, bone has emerged as an attractive biomarker for long-term Mn deposition and storage. A novel Deuterium-Deuterium (DD) neutron generator irradiation system has been simulated and constructed, incorporating moderator, reflector and shielding. This neutron activation analysis (NAA) irradiation assembly presents several desirable features, including high neutron flux, improved detection limit and acceptable neutron & photon dose, which would allow it be ready for clinical measurement. Key steps include simulation modeling and verifying, irradiation system design, detector characterization, and neutron flux and dose assessment. Activation foils were also analyzed to reveal the accurate neutron spectrum in the irradiation cave. The detection limit with this system is 0.428 ppm with 36 mSv equivalent hand dose and 52 microSv whole body effective dose.

  1. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Electric lock on hand-operated switch; control... switch; control. Electric lock on hand-operated switch shall be controlled so that it cannot be unlocked until control circuits of signals governing movements over such switch have been opened. Approach or...

  2. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Electric lock on hand-operated switch; control... switch; control. Electric lock on hand-operated switch shall be controlled so that it cannot be unlocked until control circuits of signals governing movements over such switch have been opened. Approach or...

  3. 49 CFR 236.207 - Electric lock on hand-operated switch; control.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Electric lock on hand-operated switch; control... switch; control. Electric lock on hand-operated switch shall be controlled so that it cannot be unlocked until control circuits of signals governing movements over such switch have been opened. Approach or...

  4. 49 CFR 571.123 - Standard No. 123; Motorcycle controls and displays.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...'s right hand from the throttle. Each control located on a left handlebar shall be operable by the operator's left hand throughout its full range without removal of the operator's left hand from the... rear brake control, the control shall be located on the left handlebar. If a scooter with an automatic...

  5. 49 CFR 571.123 - Standard No. 123; Motorcycle controls and displays.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...'s right hand from the throttle. Each control located on a left handlebar shall be operable by the operator's left hand throughout its full range without removal of the operator's left hand from the... rear brake control, the control shall be located on the left handlebar. If a scooter with an automatic...

  6. 49 CFR 571.123 - Standard No. 123; Motorcycle controls and displays.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...'s right hand from the throttle. Each control located on a left handlebar shall be operable by the operator's left hand throughout its full range without removal of the operator's left hand from the... rear brake control, the control shall be located on the left handlebar. If a scooter with an automatic...

  7. 49 CFR 571.123 - Standard No. 123; Motorcycle controls and displays.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...'s right hand from the throttle. Each control located on a left handlebar shall be operable by the operator's left hand throughout its full range without removal of the operator's left hand from the... rear brake control, the control shall be located on the left handlebar. If a scooter with an automatic...

  8. Removal of simulated biofilm: a preclinical ergonomic comparison of instruments and operators.

    PubMed

    Graetz, Christian; Plaumann, Anna; Rauschenbach, Sebastian; Bielfeldt, Jule; Dörfer, Christof E; Schwendicke, Falk

    2016-07-01

    Periodontal scaling might cause musculoskeletal disorders, and scaling instruments might not only have different effectiveness and efficiency but also differ in their ergonomic properties. The present study assessed ergonomic working patterns of experienced (EO) and less experienced operators (LO) when using hand and powered devices for periodontal scaling and root planning. In an experimental study using periodontally affected manikins, sonic (AIR), ultrasonic (TIG) and hand instruments (GRA) were used by 11 operators (7 EO/4 LO) during simulated supportive periodontal therapy. Using an electronic motion monitoring system, we objectively assessed the working frequency and positioning of hand, neck and head. Operators' subjective evaluation of the instruments was recorded using a questionnaire. Hand instruments were used with the lowest frequency (2.57 ± 1.08 s(-1)) but greatest wrist deviation (59.57 ± 53.94°). EO used instruments more specifically than LO, and generally worked more ergonomically, with less inclination of head and neck in both the frontal and sagittal planes, especially when using hand instruments. All groups found hand instruments more tiring and difficult to use than powered instruments. Regardless of operators' experience, powered instruments were used more ergonomically and were subjectively preferred compared to hand instruments. The use of hand instruments has potential ergonomic disadvantages. However, with increasing experience, operators are able to recognise and mitigate possible risks.

  9. 49 CFR 218.107 - Additional operational requirements for hand-operated crossover switches.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-operated crossover switches. 218.107 Section 218.107 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.107 Additional operational requirements for hand-operated crossover switches. (a) Each railroad shall adopt and comply with an operating rule which...

  10. 49 CFR 218.107 - Additional operational requirements for hand-operated crossover switches.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-operated crossover switches. 218.107 Section 218.107 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.107 Additional operational requirements for hand-operated crossover switches. (a) Each railroad shall adopt and comply with an operating rule which...

  11. 49 CFR 218.107 - Additional operational requirements for hand-operated crossover switches.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-operated crossover switches. 218.107 Section 218.107 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.107 Additional operational requirements for hand-operated crossover switches. (a) Each railroad shall adopt and comply with an operating rule which...

  12. 49 CFR 218.107 - Additional operational requirements for hand-operated crossover switches.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-operated crossover switches. 218.107 Section 218.107 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.107 Additional operational requirements for hand-operated crossover switches. (a) Each railroad shall adopt and comply with an operating rule which...

  13. 49 CFR 218.107 - Additional operational requirements for hand-operated crossover switches.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-operated crossover switches. 218.107 Section 218.107 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.107 Additional operational requirements for hand-operated crossover switches. (a) Each railroad shall adopt and comply with an operating rule which...

  14. Dexterous programmable robot and control system

    NASA Astrophysics Data System (ADS)

    Engler, Charles D., Jr.

    1995-09-01

    An anatomically correct, humanlike, mechanical arm and hand is provided that an operator can control to perform with the dexterity and compliance of a human hand. Being humanlike and robotic enhances the device's control and gripper dexterity. Control of the movement of the arm and hand is performed or guided by a 'teach glove' worn by the operator. As he or she performs some hand manipulation, a controller stores signals from sensors on the exoskeleton. The sensors monitor the operator's finger-joint movement positions. These values are later translated into actuator control signals for servomotors, eventually duplicating the operator's movement.

  15. 49 CFR 218.105 - Additional operational requirements for hand-operated main track switches.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-operated main track switches. 218.105 Section 218.105 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.105 Additional operational requirements for hand-operated main track switches. (a) Each railroad shall adopt and comply with an operating rule...

  16. 49 CFR 218.105 - Additional operational requirements for hand-operated main track switches.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-operated main track switches. 218.105 Section 218.105 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.105 Additional operational requirements for hand-operated main track switches. (a) Each railroad shall adopt and comply with an operating rule...

  17. 49 CFR 218.105 - Additional operational requirements for hand-operated main track switches.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-operated main track switches. 218.105 Section 218.105 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.105 Additional operational requirements for hand-operated main track switches. (a) Each railroad shall adopt and comply with an operating rule...

  18. 49 CFR 218.105 - Additional operational requirements for hand-operated main track switches.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-operated main track switches. 218.105 Section 218.105 Transportation Other Regulations Relating to... PRACTICES Handling Equipment, Switches, and Fixed Derails § 218.105 Additional operational requirements for hand-operated main track switches. (a) Each railroad shall adopt and comply with an operating rule...

  19. 76 FR 10086 - Notice of Application for Approval of Discontinuance or Modification of a Railroad Signal System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-23

    ... automatic signals as well as the circuit controllers from five hand-operated switches and one hand-operated crossover. The hand-operated switches will remain in the application area without signal protection. The... submitting written views, data, or comments. FRA does not anticipate scheduling a public hearing in...

  20. A method of assessing the efficacy of hand sanitizers: use of real soil encountered in the food service industry.

    PubMed

    Charbonneau, D L; Ponte, J M; Kochanowski, B A

    2000-04-01

    In many outbreaks of foodborne illness, the food worker has been implicated as the source of the infection. To decrease the likelihood of cross-contamination, food workers must clean and disinfect their hands frequently. To ensure their effectiveness, hand disinfectants should be tested using rigorous conditions that mimic normal use. Currently, several different methods are used to assess the efficacy of hand disinfectants. However, most of these methods were designed with the health care worker in mind and do not model the specific contamination situations encountered by the food worker. To fill this void, we developed a model that uses soil from fresh meat and a means of quantifying bacteria that is encountered and transferred during food preparation activities. Results of studies using various doses of para-chloro-meta-xylenol and triclosan confirm that the method is reproducible and predictable in measuring the efficacy of sanitizers. Consistent, dose-dependent results were obtained with relatively few subjects. Other studies showed that washing hands with a mild soap and water for 20 s was more effective than applying a 70% alcohol hand sanitizer.

  1. Sensing And Force-Reflecting Exoskeleton

    NASA Technical Reports Server (NTRS)

    Eberman, Brian; Fontana, Richard; Marcus, Beth

    1993-01-01

    Sensing and force-reflecting exoskeleton (SAFiRE) provides control signals to robot hand and force feedback from robot hand to human operator. Operator makes robot hand touch objects gently and manipulates them finely without exerting excessive forces. Device attaches to operator's hand; comfortable and lightweight. Includes finger exoskeleton, cable mechanical transmission, two dc servomotors, partial thumb exoskeleton, harness, amplifier box, two computer circuit boards, and software. Transduces motion of index finger and thumb. Video monitor of associated computer displays image corresponding to motion.

  2. The interplay between dose and immune system activation determines fungal infection outcome in the African malaria mosquito, Anopheles gambiae.

    PubMed

    Rhodes, Victoria L; Thomas, Matthew B; Michel, Kristin

    2018-08-01

    The Toll pathway is a central regulator of antifungal immunity in insects. In mosquitoes, the Toll pathway affects infections with the fungal entomopathogen, Beauveria bassiana, which is considered a potential mosquito biopesticide. We report here the use of B. bassiana strain I93-825 in Anopheles gambiae to analyze the impact of Toll pathway modulation on mosquito survival. Exposure to a narrow dose range of conidia by direct contact decreased mosquito longevity and median survival. In addition, fungal exposure dose correlated positively and linearly with hazard ratio. Increased Toll signaling by knockdown of its inhibitor, cactus, decreased survivorship of uninfected females, increased mosquito survival after low dose B. bassiana exposure, but had little effect following exposure to higher doses. This observed trade-off could have implications for development of B. bassiana as a prospective vector control tool. On the one hand, selection for small increases in mosquito immune signaling across a narrow dose range could impair efficacy of B. bassiana. On the other hand, costs of immunity and the capacity for higher doses of fungus to overwhelm immune responses could limit evolution of resistance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed

    Virokannas, H

    1995-05-01

    31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration.

  4. Time related neutralization of two doses acetyl salicylic acid.

    PubMed

    Aguejouf, O; Malfatti, E; Belon, P; Doutremepuich, C

    2000-11-15

    Aspirin has a well established role in the prevention of arterial thrombosis. Discussion on the efficacy and safety of aspirin in the treatment and prophylaxis of thrombosis has become an important issue. In fact, hemorrhage complications are often associated with its use. On the other hand, previous studies showed unexpected thrombotic potencies associated with the presence of this drug at ultra low doses (ULD) in the circulation. In this study, we aimed to evaluate the effect of aspirin at ULD, injected 1, 2, or 3 hours after the administration of aspirin at 100 mg/kg, on hemostasis and bleeding in rats. We used an experimental model of thrombosis induced by laser beams to evaluate these effects. Platelet aggregation was determined by Cardinal and Flower method. Results from this investigation demonstrate that the neutralizing effect of aspirin at ULD did not operate significantly 1 hour after the injection of aspirin at 100 mg/kg. This effect was observed 2 and 3 hours after. The use of aspirin at ULD to neutralize the side effects of aspirin at high doses will reduce the hemorrhagic risk during extra corporeal circulation. The therapeutic benefit and safety of aspirin therapy in the treatment of cardiovascular diseases can be obtained.

  5. Comparison of defects in ProTaper hand-operated and engine-driven instruments after clinical use.

    PubMed

    Cheung, G S P; Bian, Z; Shen, Y; Peng, B; Darvell, B W

    2007-03-01

    To compare the type of defects and mode of material failure of engine-driven and hand-operated ProTaper instruments after clinical use. A total of 401 hand-operated and 325 engine-driven ProTaper instruments were discarded from an endodontic clinic over 17 months. Those that had fractured were examined for plastic deformation in lateral view and remounted for fractographical examination in scanning electron microscope. The mode of fracture was classified as 'fatigue' or 'shear' failure. The lengths of fractured segments in both instruments were recorded. Any distortion in hand instrument was noted. Data were analysed using chi-square, Fisher's exact or Student's t-test, where appropriate. Approximately 14% of all discarded hand-operated instruments and 14% of engine-driven instruments were fractured. About 62% of hand instruments failed because of shear fracture, compared with approximately 66% of engine-driven instruments as a result of fatigue (P < 0.05). Approximately 16% of hand instruments were affected by shear, and either remained intact or was fractured, compared with 5% of engine-driven instruments (P < 0.05). The length of the broken fragment was significantly shorter in hand versus engine-driven group (P < 0.05). Approximately 7% of hand instruments were discarded intact but distorted (rarely for engine-driven instruments); all were in the form of unscrewing of the flutes. The location of defects in hand Finishing instruments was significantly closer to the tip than that for Shaping instruments (P < 0.05). Under the conditions of this study (possibly high usage), the failure mode of ProTaper engine-driven and hand-operated instruments appeared to be different, with shear failure being more prevalent in the latter.

  6. Assessing possible exposures of ground troops to Agent Orange during the Vietnam War: the use of contemporary military records.

    PubMed

    Young, Alvin L; Cecil, Paul F; Guilmartin, John F

    2004-01-01

    Potential exposure of ground troops in Vietnam to Agent Orange and 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) remains controversial despite the passage of 30 years since the Vietnam War. Because of uncertainty over the serum dioxin levels in ground troops at the end of their service in Vietnam, attempts have been made to develop a methodology for characterizing exposure of ground troops in Vietnam to Agent Orange and other herbicides based upon historical reconstruction from military records. Historical information is often useful in evaluating and modeling exposure, but such information should be reasonably accurate, complete, and reliable. This paper reviews the procedures and supporting historical information related to the spraying of herbicides in Vietnam. The historical information is classified into two categories: procedural information and operational information. Procedural information covered the process and procedures followed in spraying herbicides from US Air Force fixed wing aircraft (Operation RANCH HAND) in Vietnam, and included approval procedures for spray missions, the criteria required to conduct a mission, the control exercised by the Forward Air Controller and the Tactical Air Control Center and the characteristics of the equipment used to apply the herbicides. Operational information includes data from the RANCH HAND Daily Air Activities Reports, which included geographic locations of specific spray missions, the amount of herbicide sprayed by a specific mission, reports of battle damage to spray aircraft, reports of fighter aircraft support for aerial spray missions, and any comments, such as reasons for canceling a mission. Historical information demonstrates that herbicide spray missions were carefully planned and that spraying only occurred when friendly forces were not located in the target area. RANCH HAND spray missions were either not approved or cancelled if approved when there were friendly forces in the area designated for spraying. Stringent criteria had to be met before spray missions could be approved. The operational information shows that spray missions for both defoliation and crop destruction were conducted in an extremely hostile environment. Heavy 'fighter suppression' with antipersonnel ordnance was used to minimize the impact of hostile ground fire on RANCH HAND aircraft. Procedures were in place that prohibited movement of troops into sprayed areas immediately after a mission due to the possible presence of unexploded ordnance delivered by fighter aircraft supporting RANCH HAND missions. The optimal nature of the spray equipment and application procedures minimized the possibility of significant spray drift. Conclusions. Few friendly troops were sprayed by fixed wing aircraft during Operation RANCH HAND, which delivered 95% of all defoliants used in Vietnam. Similarly, few troops were sprayed during helicopter or surface-based spray operations, which constituted the remaining 5% of defoliants. Detailed policies and procedures for approval and execution of spray missions ensured that friendly forces were not located in the areas targeted for spraying. Fighter aircraft assigned to accompany each spray mission frequently suppressed much of the hostile fire with bombs and other ordnance. Confirmed clearance of the target area was necessary to avoid friendly casualties. Historical records establish that these policies and procedures were strictly followed. Exposure of troops whether from direct spraying or movement through areas recently sprayed was very unlikely. The wartime military records of troop positions and herbicide operations are valuable for some purposes, but have specific limitations in exposure reconstruction. The completeness and accuracy of the geographic data (maps used by RANCH HAND and military ground units) were dependent upon the inherent precision of the map, the accuracy with which it depicted surface features, and the completeness and accuracy of the information on which it is based. Navigation by the crew using visual orientation and reference to the map was the only means that aircrew on spray missions had for establishing their locations. A Forward Air Controller independent of Operation RANCH HAND was present at the location of each spray target immediately before and during spraying operations to verify the target location and ensure that friendly forces were clear of the target area. Anecdotal reports of direct spraying of troops in Vietnam likely reflect the RANCH HAND missions spraying insecticide for mosquito control at regular intervals from March 1967 through February 1972. Outlook. The distribution and levels of serum dioxin in RANCH HAND veterans and the US Army Chemical Corps Vietnam veterans (the unit responsible for helicopter and ground-based spray operations) are distinguishable from typical levels in the population decades after the Vietnam conflict. An exposure model similar to that proposed in the 2003 report of the Institute of Medicine's Committee on 'Characterizing Exposure of Veterans to Agent Orange and Other Herbicides Used in Vietnam' was tested in 1988 by the Centers for Disease Control and Prevention and found to be a poor predictor of absorbed dose of TCDD. Military records during the Vietnam War lack the precision to determine that troops were directly sprayed with herbicides during Operation RANCH HAND, especially given the procedures in place to ensure clearance of friendly forces from the target area and the lack of elevated serum levels of TCDD in ground troops judged to have operated in heavily sprayed areas.

  7. Improved accuracy of screw implantation could decrease the incidence of post-operative hydrothorax? O-arm navigation vs. free-hand in thoracic spinal deformity correction surgery.

    PubMed

    Zhao, Zhihui; Liu, Zhen; Hu, Zongshan; Tseng, Changchun; Li, Jie; Pan, Wei; Qiu, Yong; Zhu, Zezhang

    2018-03-16

    The purpose of this study was to analyze the occurrence of PE after intra-operative O-arm navigation-assisted surgery and determine whether the post-operative PE incidence could be decreased by using O-arm navigation as compared to conventional free-hand technique. A cohort of 27 patients with spinal deformity who were operated upon with an O-arm navigated system (group A) between 2013 and 2016 were enrolled in the study. A total of 27 curve-matched patients treated by conventional free-hand technique were included as the control group (group B). Whole spine posterior-anterior and lateral radiographs, and CT scans were taken pre and post-operation. Radiologic parameters and volume of PE were measured and compared between the two groups. There were no significant differences in age, Cobb angle, and sagittal contour between the two groups pre-operatively. The mean total volume of post-operative PE was significantly larger in the free-hand group (p < 0.001). In the O-arm group, 59 malpositioned screws were identified in 22 patients. In the free-hand group, 88 malpositioned screws were found among 26 patients. The screw perforation rate was higher in the free-hand group than in the O-arm group (p = 0.007). In the O-arm group, the mean volume of PE was significantly larger among patients with malpositioned screws than those without malpositioned screws (p < 0.001), as well as in the free-hand group. The volume of PE after correction surgery can be significantly decreased by application of O-arm navigation system as compared to conventional free-hand technique. We ascribed the improvement to the accuracy of screw implantation navigated by O-arm.

  8. Are We Done with Respiratory Deposition and Dosimetry of Inhaled Particles?

    EPA Science Inventory

    Deposition of inhaled particles and subsequent dose estimation in the respiratory airways is an essential information needed for assessing potential health hazard of airborne pollutant particles on the one hand and therapeutic efficacy of drug aerosols on the other hand. Over sev...

  9. Respiratory dose assessment of inhaled particles: continuing progress

    EPA Science Inventory

    Internal dose is a key factor for determining the health risk ofinhaled pollutant particles on the one hand and the efficacy ofdrug inhalantsonthe other. Accurateestimation ofrespiratorydose, however, is a difficult task because multiple factors come to play roles in the process....

  10. Ergonomic analysis of fastening vibration based on ISO Standard 5349 (2001).

    PubMed

    Joshi, Akul; Leu, Ming; Murray, Susan

    2012-11-01

    Hand-held power tools used for fastening operations exert high dynamic forces on the operator's hand-arm, potentially causing injuries to the operator in the long run. This paper presents a study that analyzed the vibrations exerted by two hand-held power tools used for fastening operations with the operating exhibiting different postures. The two pneumatic tools, a right-angled nut-runner and an offset pistol-grip, are used to install shearing-type fasteners. A tri-axial accelerometer is used to measure the tool's vibration. The position and orientation of the transducer mounted on the tool follows the ISO-5349 Standard. The measured vibration data is used to compare the two power tools at different operating postures. The data analysis determines the number of years required to reach a 10% probability of developing finger blanching. The results indicate that the pistol-grip tool induces more vibration in the hand-arm than the right-angled nut-runner and that the vibrations exerted on the hand-arm vary for different postures. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  11. High-dose progestins for the treatment of cancer anorexia-cachexia syndrome: a systematic review of randomised clinical trials.

    PubMed

    Maltoni, M; Nanni, O; Scarpi, E; Rossi, D; Serra, P; Amadori, D

    2001-03-01

    The aim of the present study was to summarise evidence from scientific studies on cancer anorexia-cachexia syndrome in order to assess and highlight the efficacy of high-dose progestins (megestrol acetate and medroxyprogesterone acetate) compared with placebo in patients with hormone-independent tumors. A systematic review of published randomised clinical trials was carried out by an extensive electronic and hand search through databases, relevant journals and books, congress, proceedings, reference lists, without any language or year of publication restriction. The research was conducted by two independent operators who collected the data in a form specifically designed for this review. Among the several possible outcomes, appetite and body weight were chosen. Fifteen randomised clinical trials (more than 2000 patients) were retrieved for the review. There was a statistically significant advantage for high-dose progestins as regards improved appetite: pooled odds ratio (OR) = 4.23, 95% confidence interval (CI): 2.53-7.04. Although the effect of high-dose progestins on body weight was less impressive, statistical significance was also reached for this outcome: pooled OR = 2.66, 95% CI: 1.80-3.92. Treatment morbidity was very low, due to the brief period of the treatment in most of the studies. The effects of high-dose progestins on appetite and body weight were clearly demonstrated. However, further studies are undoubtedly warranted to investigate other aspects of progestin activity, especially as regards dosage, duration and timing with best therapeutic index.

  12. Risk-benefit analysis of navigation techniques for vertebral transpedicular instrumentation: a prospective study.

    PubMed

    Noriega, David C; Hernández-Ramajo, Rubén; Rodríguez-Monsalve Milano, Fiona; Sanchez-Lite, Israel; Toribio, Borja; Ardura, Francisco; Torres, Ricardo; Corredera, Raul; Kruger, Antonio

    2017-01-01

    Pedicle screws in spinal surgery have allowed greater biomechanical stability and higher fusion rates. However, malposition is very common and may cause neurologic, vascular, and visceral injuries and compromise mechanical stability. The purpose of this study was to compare the malposition rate between intraoperative computed tomography (CT) scan assisted-navigation and free-hand fluoroscopy-guided techniques for placement of pedicle screw instrumentation. This is a prospective, randomized, observational study. A total of 114 patients were included: 58 in the assisted surgery group and 56 in the free-hand fluoroscopy-guided surgery group. Analysis of screw position was assessed using the Heary classification. Breach severity was defined according to the Gertzbein classification. Radiation doses were evaluated using thermoluminescent dosimeters, and estimates of effective and organ doses were made based on scan technical parameters. Consecutive patients with degenerative disease, who underwent surgical procedures using the free-hand, or intraoperative navigation technique for placement of transpedicular instrumentation, were included in the study. Forty-four out of 625 implanted screws were malpositioned: 11 (3.6%) in the navigated surgery group and 33 (10.3%) in the free-hand group (p<.001). Screw position according to the Heary scale was Grade II (4 navigated surgery, 6 fluoroscopy guided), Grade III (3 navigated surgery, 11 fluoroscopy guided), Grade IV (4 navigated surgery, 16 fluoroscopy guided), and Grade V (1 fluoroscopy guided). There was only one symptomatic case in the conventional surgery group. Breach severity was seven Grade A and four Grade B in the navigated surgery group, and eight Grade A, 24 Grade B, and one Grade C in free-hand fluoroscopy-guided surgery group. Radiation received per patient was 5.8 mSv (4.8-7.3). The median dose received in the free-hand fluoroscopy group was 1 mGy (0.8-1.1). There was no detectable radiation level in the navigation-assisted surgery group, whereas the effective dose was 10 µGy in the free-hand fluoroscopy-guided surgery group. Malposition rate, both symptomatic and asymptomatic, in spinal surgery is reduced when using CT-guided placement of transpedicular instrumentation compared with placement under fluoroscopic guidance, with radiation values within the safety limits for health. Larger studies are needed to determine risk-benefit in these patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Next generation distal locking for intramedullary nails using an electromagnetic X-ray-radiation-free real-time navigation system.

    PubMed

    Hoffmann, Michael; Schröder, Malte; Lehmann, Wolfgang; Kammal, Michael; Rueger, Johannes Maria; Herrman Ruecker, Andreas

    2012-07-01

    Distal locking marks one challenging step during intramedullary nailing that can lead to an increased irradiation and prolonged operation times. The aim of this study was to evaluate the reliability and efficacy of an X-ray-radiation-free real-time navigation system for distal locking procedures. A prospective randomized cadaver study with 50 standard free-hand fluoroscopic-guided and 50 electromagnetic-guided distal locking procedures was performed. All procedures were timed using a stopwatch. Intraoperative fluoroscopy exposure time and absorbed radiation dose (mGy) readings were documented. All tibial nails were locked with two mediolateral and one anteroposterior screw. Successful distal locking was accomplished once correct placement of all three screws was confirmed. Successful distal locking was achieved in 98 cases. No complications were encountered using the electromagnetic navigation system. Eight complications arose during free-hand fluoroscopic distal locking. Undetected secondary drill slippage on the ipsilateral cortex accounted for most problems followed by undetected intradrilling misdirection causing a fissural fracture of the contralateral cortex while screw insertion in one case. Compared with the free-hand fluoroscopic technique, electromagnetically navigated distal locking provides a median time benefit of 244 seconds without using ionizing radiation. Compared with the standard free-hand fluoroscopic technique, the electromagnetic guidance system used in this study showed high reliability and was associated with less complications, took significantly less time, and used no radiation exposure for distal locking procedures. Therapeutic study, level II.

  14. Forwardly movable assembly for a firearm

    DOEpatents

    Crandall, David L [Idaho Falls, ID; Watson, Richard W [Blackfoot, ID

    2007-06-05

    A forwardly movable assembly for a firearm, the forwardly movable assembly adapted to be disposed in operative relationship relative to the other operative parts of a firearm, the firearm having in operative relationship each with one or more of the others: a barrel, a receiver, and at least one firing mechanism; the forwardly movable assembly comprising: the barrel and the receiver operatively connected with each other; a movable hand support structure to which at least one of the barrel and the receiver is connected, the barrel being movable therewith, the movable hand support structure being adapted to be gripped by an operator of the firearm; the forwardly movable assembly being adapted to be moved forward by an operator upon gripping the movable hand support structure and manually maneuvering the hand support structure forwardly; and, as the forwardly movable assembly is moved forwardly, the firing mechanism is completely disengaged therefrom and held substantially stationary relative thereto.

  15. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2010-01-01 2010-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  16. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2014-01-01 2014-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  17. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2014-01-01 2014-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  18. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2011-01-01 2011-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  19. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2012-01-01 2012-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  20. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2013-01-01 2013-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  1. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2011-01-01 2011-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  2. 10 CFR 32.28 - Same: Table of organ doses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... organs; gonads; or lens of eye 0.005 0.5 15 Hands and forearms; feet and ankles; localized areas of skin... 10 Energy 1 2010-01-01 2010-01-01 false Same: Table of organ doses. 32.28 Section 32.28 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.28 Same: Table of organ doses. Part of...

  3. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2013-01-01 2013-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  4. 10 CFR 32.24 - Same: Table of organ doses.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... blood-forming organs; gonads: or lens of eye 0.001 0.01 0.5 15 Hands and forearms; feet and ankles... 10 Energy 1 2012-01-01 2012-01-01 false Same: Table of organ doses. 32.24 Section 32.24 Energy... CONTAINING BYPRODUCT MATERIAL Exempt Concentrations and Items § 32.24 Same: Table of organ doses. Part of...

  5. Rehand: Realistic electric prosthetic hand created with a 3D printer.

    PubMed

    Yoshikawa, Masahiro; Sato, Ryo; Higashihara, Takanori; Ogasawara, Tsukasa; Kawashima, Noritaka

    2015-01-01

    Myoelectric prosthetic hands provide an appearance with five fingers and a grasping function to forearm amputees. However, they have problems in weight, appearance, and cost. This paper reports on the Rehand, a realistic electric prosthetic hand created with a 3D printer. It provides a realistic appearance that is same as the cosmetic prosthetic hand and a grasping function. A simple link mechanism with one linear actuator for grasping and 3D printed parts achieve low cost, light weight, and ease of maintenance. An operating system based on a distance sensor provides a natural operability equivalent to the myoelectric control system. A supporter socket allows them to wear the prosthetic hand easily. An evaluation using the Southampton Hand Assessment Procedure (SHAP) demonstrated that an amputee was able to operate various objects and do everyday activities with the Rehand.

  6. [Hand management in recessive dystrophic bullous epydermolysis].

    PubMed

    Pajardi, G; Novelli, C; Parolo, C; Proserpio, G; Tegon, M; Vecchi, S

    2011-01-01

    Recessive distrofic epidermolysis bullosa creates severe hand deformities with disabling functional limitations. Hand surgeon should perform surgery when deformity inibits function, in order to restore the pinch. We present our experience on 44 patients and 58 operated hands, with the following schema: hand degloving, grafting of the first web and intraoperative dynamic splinting. In 30 patient with an 8 years follow up, 25 had had good or excellent results, and the 5 remaining shows early recurrence. Association of a correct surgical approach and adequate intra and post-operative rehabilitation improve hand function and a slow down inevitable recurrence.

  7. Dose-response relation between exposure to two types of hand-arm vibration and sensorineural perception of vibration.

    PubMed Central

    Virokannas, H

    1995-01-01

    OBJECTIVES--31 railway workers and 32 lumberjacks were examined to compare the dose-response relation between the exposure to two types of hand-arm vibration and the sensory disturbances in peripheral nerves as evaluated by the vibration perception thresholds (VPTs). METHODS--Clinical examinations were carried out that included measurements of the VPTs, and electroneuromyography (ENMG), and an inquiry to confirm the use of vibrating tools. Diseases of the central nervous system and neuropathies were checked by inquiry and a clinical examination, diabetes was excluded by a blood sample analysis, and the subjects with carpal tunnel syndrome confirmed with ENMG were excluded from the study. RESULTS--Lifetime use of hand held tamping machines (railway workers) and chain saws (lumberjacks) had a significant correlation with the VPTs at frequencies from 32 to 500 Hz. The increase of the VPTs (250 Hz) in relation to use of vibrating tools was 1.8-fold higher on average in the whole group and 2.3-fold higher in the young (< 45) railway workers who had used hand held tamping machines, than in the corresponding groups of lumberjacks, who had used chain saws, whereas the frequency weighted acceleration of vibration in tamping machines was fourfold. CONCLUSION--There was a significant dose-response relation between the exposure to hand-arm vibration and the VPTs. The VPTs as a function of the frequency weighted acceleration of vibration and the exposure to vibration gave promising results for assessment of the risk of damage to sensory nerves induced by vibration. PMID:7795756

  8. [A Case of a Multidisciplinary Team Approach to Serious Hand-Foot Syndrome Induced by High-Dose Cytarabine Therapy].

    PubMed

    Sakurada, Hiroaki; Aoi, Miki; Yuge, Masaaki; Sugimura, Yuriko; Kitamura, Kunio; Yamamura, Masumi; Tachi, Tomoya; Teramachi, Hitomi

    2016-07-01

    A 40's year-old female patient with acute myeloblastic leukemia received high-dose cytarabine(HD-Ara-C)as her third induction therapy. Because the pharmacist in charge noticed on a prior interview that she had experienced a mild skin eruption similar to hand-foot syndrome(HFS)in the previous round oftherapy(idarubicin and cytarabine), heparinoid lotion and hypoallergenic soap were used to prevent HFS. However, HFS occurred on day 3, and further developed on day 6 to grade 3 with painful erythema, swelling, and paresthesia affecting the entire surface of both hands. We cared for her with moisturization, lifestyle guidance, rotation of steroid ointment, and occlusive dressing techniques according to a multidisciplinary team approach composed ofa hematologist, dermatologist, pharmacist, and nurse. Her symptoms resolved on day 40.

  9. Effectiveness of using low rate fluoroscopy to reduce an examiner's radiation dose during lumbar nerve root block.

    PubMed

    Yamane, Kentaro; Kai, Nobuo; Mazaki, Tetsuro; Miyamoto, Tadashi; Matsushita, Tomohiro

    2018-06-13

    Long-term exposure to radiation can lead to gene mutations and increase the risk of cancer. Low rate fluoroscopy has the potential to reduce the radiation exposure for both the examiner and the patient during various fluoroscopic procedures. The purpose of this study was to evaluate the impact of low rate fluoroscopy on reducing an examiner's radiation dose during nerve root block. A total of 101 lumbar nerve root block examinations were performed at our institute during a 6-month period. During the first 3 months, low rate fluoroscopy was performed at 7.5 frames/s (FPS) in 54 examinations, while 47 were performed at 15 FPS during the last 3 months. The examiner wore a torso protector, a neck protector, radiation protection gloves, and radiation protection glasses. Optically stimulated luminescence (OSL) dosimeter badges were placed on both the inside and the outside of each protector. The dosimeters were exchanged every month. Radiation doses (mSv) were measured as the integrated radiation quantity every month from the OSL dosimeters. The effective and equivalent doses for the hands, skin, and eyes were investigated. The mean monthly equivalent doses were significantly lower both inside and outside the hand protector for the 7.5 FPS versus 15 FPS (inside; P = 0.021, outside; P = 0.024). There were no significant differences between the two groups for the mean monthly calculated effective dose for each protector's condition. Radiation exposure was significantly reduced for the skin on the examiner's hand when using low rate fluoroscopy at 7.5 FPS, with no noticeable decrease in image quality or prolonged fluoroscopy time. Copyright © 2018. Published by Elsevier B.V.

  10. Low-dose 5-fluorouracil in combination with salicylic acid for the treatment of actinic keratoses on the hands and/or forearms - results of a non-interventional study.

    PubMed

    Reinhold, U; Hadshiew, I; Melzer, A; Prechtl, A

    2017-03-01

    As an in situ carcinoma, actinic keratoses should be treated early. Previous studies on the efficacy of a low-dose 0.5% 5-fluorouracil solution in combination with 10% salicylic acid (low-dose 5-FU/SA) are mostly related to lesions appearing on the head and face. In contrast, actinic keratoses (AK) lesions of the upper extremities are considered to be difficult to treat. The efficacy of low-dose 5-FU/SA in the treatment of actinic keratoses on the hands and/or forearms was studied for the first time in this non-interventional study (NIS) under practical conditions in a large patient population. In addition to the clinical course during therapy and a follow-up period, the length of application and adherence were documented. As part of this NIS, 649 patients with AK were treated at 207 centres with low-dose 5-FU/SA. The data of the study were recorded at baseline, optionally during an intermediate examination, at the end of therapy and during a final assessment. The average number of AK lesions decreased during the entire observation period by 92%. Side-effects were documented only rarely in the form of local skin reactions (2%). The attending physicians assessed the efficacy, tolerability and safety of the therapy as being predominantly very good or good (in each case ≥90%). AK lesions on the hands and/or forearms were effectively treated with low-dose 5-FU/SA under routine conditions in dermatological practice and the treatment was well tolerated. © 2016 European Academy of Dermatology and Venereology.

  11. Exercise-induced hand tremor: a possible test for beta 2-adrenoceptor selectivity in man?

    PubMed Central

    Abila, B; Wilson, J F; Marshall, R W; Richens, A

    1986-01-01

    The effects of intravenous doses of propranolol, sotalol, timolol, atenolol and placebo on exercise-induced tachycardia and exercise-induced increases in hand tremor were assessed in four healthy volunteers. All active drugs produced significant reductions in exercise-induced tachycardia. Exercise caused consistent significant increases in hand tremor which were blocked by the three non-cardioselective drugs but not by atenolol or placebo. The blockade of exercise-induced hand tremor is suggested as a possible test for the assessment of the selectivity of beta-adrenoceptor blockade in man. PMID:2874824

  12. Evaluation of radiation dose during the percutaneous angioplasty for arteriovenous shunt assembling

    NASA Astrophysics Data System (ADS)

    Ting, Chien-Yi; Wu, Wen-Shiann; Tang, Kuo-Ting; Wang, Hsin-Ell; Lin, Chun-Chih

    2017-11-01

    Percutaneous angioplasty (PTA) for dysfunctional hemodialysis is usually performed by radiologists, but not cardiologists, in Taiwan, so that the radiation dose in patients and physicians are usually unknown and related studies are rare. In this study, we are pioneering an investigation into the radiation dose in percutaneous angioplasty for arteriovenous shunt assembling and the effect of RADPAD device, a lead-free surgical drape containing Bi and Ba, on the decrease of a radiation dose in the non-targeted organs of the patient and also the operator. The radiation dose in a typical digital subtraction angiography (DSA) by the PTA protocol under a fixed field of view (FOV), was measured with optically simulated luminescent dosimeters arranged in a PIXY RS-102 anthropomorphic phantom. The results indicate that there is a significant dose reduction at the hands (0.022±0.002 mGy before treatment vs. 0.014±0.001 mGy after treatment; P=0.021), but not at the lens (0.027±0.003 mGy before treatment vs. 0.018±0.001 mGy after treatment; P=0.058), and the gonads (0.026±0.003 mGy before treatment vs. 0.020±0.001 mGy after treatment; P=0.058), of the cardiologist/operator after treatment with the RADPAD drape. At the patient's abdomen, the dose significantly decreased from 1.597±0.104 mGy to 0.031±0.002 mGy (P<0.001) after treated with the RADPAD shield. For the chest, lens and thyroid in the patient, the doses were respectively 0.154±0.100 mGy (compared to 0.049±0.001 mGy after treated with the RADPAD drape; P=0.0002), 0.066±0.001 mGy (compared to 0.021±0.001 mGy after the RADPAD treatment; P=0.009), and 0.208±0.002 mGy (compared to 0.042±0.003 mGy after shielded with the RADPAD drape; P<0.0001), which represents an apparent reduction in dose. However, no significant difference was found in the dose-area product between before (179.9±0.1mGy.cm2) and after (177.4±0.1mGy.cm2) the treatment (P=0.38). In conclusion, the RADPAD drape significantly reduced radiation exposure to the patient during the PTA for the arteriovenous shunt assembling, which is suggested should be applied to the current cardiac catheterization.

  13. Radiological risk from consuming fish and wildlife to Native Americans on the Hanford Site (USA).

    PubMed

    Delistraty, Damon; Van Verst, Scott; Rochette, Elizabeth A

    2010-02-01

    Historical operations at the Hanford Site (Washington State, USA) have released a wide array of non-radionuclide and radionuclide contaminants into the environment. As a result of stakeholder concerns, Native American exposure scenarios have been integrated into Hanford risk assessments. Because its contribution to radiological risk to Native Americans is culturally and geographically specific but quantitatively uncertain, a fish and wildlife ingestion pathway was examined in this study. Adult consumption rates were derived from 20 Native American scenarios (based on 12 studies) at Hanford, and tissue concentrations of key radionuclides in fish, game birds, and game mammals were compiled from the Hanford Environmental Information System (HEIS) database for a recent time interval (1995-2007) during the post-operational period. It was assumed that skeletal muscle comprised 90% of intake, while other tissues accounted for the remainder. Acknowledging data gaps, median concentrations of eight radionuclides (i.e., Co-60, Cs-137, Sr-90, Tc-99, U-234, U-238, Pu-238, and Pu-239/240) in skeletal muscle and other tissues were below 0.01 and 1 pCi/g wet wt, respectively. These radionuclide concentrations were not significantly different (Bonferroni P>0.05) on and off the Hanford Site. Despite no observed difference between onsite and offsite tissue concentrations, radiation dose and risk were calculated for the fish and wildlife ingestion pathway using onsite data. With median consumption rates and radionuclide tissue concentrations, skeletal muscle provided 42% of the dose, while other tissues (primarily bone and carcass) accounted for 58%. In terms of biota, fish ingestion was the largest contributor to dose (64%). Among radionuclides, Sr-90 was dominant, accounting for 47% of the dose. At median intake and radionuclide levels, estimated annual dose (0.36 mrem/yr) was below a dose limit of 15 mrem/yr recommended by the United States Environmental Protection Agency (USEPA), as well as below a dose limit of 100 mrem/yr proposed by the International Commission on Radiation Protection (ICRP). Similarly, lifetime cancer risk (1.7E-5), calculated with median inputs, was below risk levels corresponding to these dose limits. However, our dose and risk estimates apply to only one pathway within a multidimensional exposure scenario for Native Americans. On the other hand, radiation dose and risk corresponding to onsite tissue concentrations were not significantly different from those corresponding to offsite (background) concentrations. Recognizing uncertainties in exposure and toxicity assessments, our results may facilitate informed decision making and optimize resource allocation within a risk assessment framework at the Hanford Site. (c) 2009 Elsevier Inc. All rights reserved.

  14. Radiological risk from consuming fish and wildlife to Native Americans on the Hanford Site (USA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delistraty, Damon, E-mail: DDEL461@ecy.wa.gov; Verst, Scott Van; Rochette, Elizabeth A.

    Historical operations at the Hanford Site (Washington State, USA) have released a wide array of non-radionuclide and radionuclide contaminants into the environment. As a result of stakeholder concerns, Native American exposure scenarios have been integrated into Hanford risk assessments. Because its contribution to radiological risk to Native Americans is culturally and geographically specific but quantitatively uncertain, a fish and wildlife ingestion pathway was examined in this study. Adult consumption rates were derived from 20 Native American scenarios (based on 12 studies) at Hanford, and tissue concentrations of key radionuclides in fish, game birds, and game mammals were compiled from themore » Hanford Environmental Information System (HEIS) database for a recent time interval (1995-2007) during the post-operational period. It was assumed that skeletal muscle comprised 90% of intake, while other tissues accounted for the remainder. Acknowledging data gaps, median concentrations of eight radionuclides (i.e., Co-60, Cs-137, Sr-90, Tc-99, U-234, U-238, Pu-238, and Pu-239/240) in skeletal muscle and other tissues were below 0.01 and 1 pCi/g wet wt, respectively. These radionuclide concentrations were not significantly different (Bonferroni P>0.05) on and off the Hanford Site. Despite no observed difference between onsite and offsite tissue concentrations, radiation dose and risk were calculated for the fish and wildlife ingestion pathway using onsite data. With median consumption rates and radionuclide tissue concentrations, skeletal muscle provided 42% of the dose, while other tissues (primarily bone and carcass) accounted for 58%. In terms of biota, fish ingestion was the largest contributor to dose (64%). Among radionuclides, Sr-90 was dominant, accounting for 47% of the dose. At median intake and radionuclide levels, estimated annual dose (0.36 mrem/yr) was below a dose limit of 15 mrem/yr recommended by the United States Environmental Protection Agency (USEPA), as well as below a dose limit of 100 mrem/yr proposed by the International Commission on Radiation Protection (ICRP). Similarly, lifetime cancer risk (1.7E-5), calculated with median inputs, was below risk levels corresponding to these dose limits. However, our dose and risk estimates apply to only one pathway within a multidimensional exposure scenario for Native Americans. On the other hand, radiation dose and risk corresponding to onsite tissue concentrations were not significantly different from those corresponding to offsite (background) concentrations. Recognizing uncertainties in exposure and toxicity assessments, our results may facilitate informed decision making and optimize resource allocation within a risk assessment framework at the Hanford Site.« less

  15. Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose

    NASA Astrophysics Data System (ADS)

    Ding, Aiping; Mille, Matthew M.; Liu, Tianyu; Caracappa, Peter F.; Xu, X. George

    2012-05-01

    Although it is known that obesity has a profound effect on x-ray computed tomography (CT) image quality and patient organ dose, quantitative data describing this relationship are not currently available. This study examines the effect of obesity on the calculated radiation dose to organs and tissues from CT using newly developed phantoms representing overweight and obese patients. These phantoms were derived from the previously developed RPI-adult male and female computational phantoms. The result was a set of ten phantoms (five males, five females) with body mass indexes ranging from 23.5 (normal body weight) to 46.4 kg m-2 (morbidly obese). The phantoms were modeled using triangular mesh geometry and include specified amounts of the subcutaneous adipose tissue and visceral adipose tissue. The mesh-based phantoms were then voxelized and defined in the Monte Carlo N-Particle Extended code to calculate organ doses from CT imaging. Chest-abdomen-pelvis scanning protocols for a GE LightSpeed 16 scanner operating at 120 and 140 kVp were considered. It was found that for the same scanner operating parameters, radiation doses to organs deep in the abdomen (e.g., colon) can be up to 59% smaller for obese individuals compared to those of normal body weight. This effect was found to be less significant for shallow organs. On the other hand, increasing the tube potential from 120 to 140 kVp for the same obese individual resulted in increased organ doses by as much as 56% for organs within the scan field (e.g., stomach) and 62% for those out of the scan field (e.g., thyroid), respectively. As higher tube currents are often used for larger patients to maintain image quality, it was of interest to quantify the associated effective dose. It was found from this study that when the mAs was doubled for the obese level-I, obese level-II and morbidly-obese phantoms, the effective dose relative to that of the normal weight phantom increased by 57%, 42% and 23%, respectively. This set of new obese phantoms can be used in the future to study the optimization of image quality and radiation dose for patients of different weight classifications. Our ultimate goal is to compile all the data derived from these phantoms into a comprehensive dosimetry database defined in the VirtualDose software.

  16. 49 CFR 218.109 - Hand-operated fixed derails.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Hand-operated fixed derails. 218.109 Section 218.109 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Handling Equipment, Switches, and Fixed...

  17. 49 CFR 218.109 - Hand-operated fixed derails.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Hand-operated fixed derails. 218.109 Section 218.109 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Handling Equipment, Switches, and Fixed...

  18. 49 CFR 218.109 - Hand-operated fixed derails.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Hand-operated fixed derails. 218.109 Section 218.109 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Handling Equipment, Switches, and Fixed...

  19. 49 CFR 218.109 - Hand-operated fixed derails.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Hand-operated fixed derails. 218.109 Section 218.109 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Handling Equipment, Switches, and Fixed...

  20. 49 CFR 218.109 - Hand-operated fixed derails.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Hand-operated fixed derails. 218.109 Section 218.109 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD OPERATING PRACTICES Handling Equipment, Switches, and Fixed...

  1. Performance of a GM tube based environmental dose rate monitor operating in the Time-To-Count mode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zickefoose, J.; Kulkarni, T.; Martinson, T.

    The events at the Fukushima Daiichi power plant in the aftermath of a natural disaster underline the importance of a large array of networked environmental monitors to cover areas around nuclear power plants. These monitors should meet a few basic criteria: have a uniform response over a wide range of gamma energies, have a uniform response over a wide range of incident angles, and have a large dynamic range. Many of these criteria are met if the probe is qualified to the international standard IEC 60532 (Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - Xmore » and gamma radiation of energy between 50 keV and 7 MeV), which specifically deals with energy response, angle of incidence, dynamic range, response time, and a number of environmental characteristics. EcoGamma is a dual GM tube environmental gamma radiation monitor designed specifically to meet the requirements of IEC 60532 and operate in the most extreme conditions. EcoGamma utilizes two energy compensated GM tubes operating with a Time-To-Count (TTC) collection algorithm. The TTC algorithm extends the lifetime and range of a GM tube significantly and allows the dual GM tube probe to achieve linearity over approximately 10 decades of gamma dose rate (from the Sv/hr range to 100 Sv/hr). In the TTC mode of operation, the GM tube is not maintained in a biased condition continuously. This is different from a traditional counting system where the GM tube is held at a constant bias continuously and the total number of strikes that the tube registers are counted. The traditional approach allows for good sensitivity, but does not lend itself to a long lifetime of the tube and is susceptible to linearity issues at high count rates. TTC on the other hand only biases the tube for short periods of time and in effect measures the time between events, which is statistically representative of the total strike rate. Since the tube is not continually biased, the life of the tube is extended and the linearity is greatly improved. Testing has been performed at Pacific Northwest National Laboratory (PNNL) in the USA and confirms compliance to IEC 60532 as well as linearity (± 10%) up to 100 Sv/hr. Furthermore, a network of EcoGamma probes may be linked through available supervisory software to provide a dose rate map of an area. This allows for real time monitoring of dose rates from one (or multiple) remote locations. (authors)« less

  2. Long-term follow-up of Dupuytren disease after injection of triamcinolone acetonide in Chinese patients in Taiwan.

    PubMed

    Yin, C-Y; Yu, H-H M; Wang, J-P; Huang, Y-C; Huang, T-F; Chang, M-C

    2017-09-01

    Injection of triamcinolone acetonide is a non-operative treatment for early-stage Dupuytren disease in Caucasians, but its effectiveness in non-Caucasians is unclear. We report averaged 5-year follow-up results of 37 patients (49 affected hands) with early-stage Dupuytren disease for patients in Taiwan (non-Caucasian) who received a single dose of 5 mg triamcinolone acetonide injection into nodules monthly for 3 months. Using ultrasound, we recorded no progression of sizes of the modules following injection after 6 months. After an average 5-year follow-up, two patients with three hands (6%) experienced reactivation of the treated nodules. None required surgical intervention. Ultrasound examination showed that sizes of the treated Dupuytren nodules decreased significantly by 40% 6 months after injection and 56% at the final follow-up. We conclude that in these Chinese patients in Taiwan with early Dupuytren nodules, triamcinolone acetonide injection was effective in reducing the size of the Dupuytren nodules and maintaining long-term durable control of the nodular growth. III.

  3. A transmission infrared cell design for temperature-controlled adsorption and reactivity studies on heterogeneous catalysts

    NASA Astrophysics Data System (ADS)

    Cybulskis, Viktor J.; Harris, James W.; Zvinevich, Yury; Ribeiro, Fabio H.; Gounder, Rajamani

    2016-10-01

    A design is presented for a versatile transmission infrared cell that can interface with an external vacuum manifold to undergo in situ gas treatments and receive controlled doses of various adsorbates and probe molecules, allowing characterization of heterogeneous catalyst surfaces in order to identify and quantify active sites and adsorbed surface species. Critical design characteristics include customized temperature control for operation between cryogenic and elevated temperatures (100-1000 K) and modified Cajon fittings for operation over a wide pressure range (10-2-103 Torr) that eliminates the complications introduced when using sealants or flanges to secure cell windows. The customized, hand-tightened Cajon fittings simplify operation of the cell compared to previously reported designs, because they allow for rapid cell assembly and disassembly and, in turn, replacement of catalyst samples. In order to validate the performance of the cell, transmission infrared spectroscopic experiments are reported to characterize the Brønsted and Lewis acid sites present in H-beta and H-mordenite zeolites using cryogenic adsorption of CO (<150 K).

  4. A transmission infrared cell design for temperature-controlled adsorption and reactivity studies on heterogeneous catalysts.

    PubMed

    Cybulskis, Viktor J; Harris, James W; Zvinevich, Yury; Ribeiro, Fabio H; Gounder, Rajamani

    2016-10-01

    A design is presented for a versatile transmission infrared cell that can interface with an external vacuum manifold to undergo in situ gas treatments and receive controlled doses of various adsorbates and probe molecules, allowing characterization of heterogeneous catalyst surfaces in order to identify and quantify active sites and adsorbed surface species. Critical design characteristics include customized temperature control for operation between cryogenic and elevated temperatures (100-1000 K) and modified Cajon fittings for operation over a wide pressure range (10 -2 -10 3 Torr) that eliminates the complications introduced when using sealants or flanges to secure cell windows. The customized, hand-tightened Cajon fittings simplify operation of the cell compared to previously reported designs, because they allow for rapid cell assembly and disassembly and, in turn, replacement of catalyst samples. In order to validate the performance of the cell, transmission infrared spectroscopic experiments are reported to characterize the Brønsted and Lewis acid sites present in H-beta and H-mordenite zeolites using cryogenic adsorption of CO (<150 K).

  5. Vocal Dose Measures: Quantifying Accumulated Vibration Exposure in Vocal Fold Tissues

    PubMed Central

    Titze, Ingo R.; Švec, Jan G.; Popolo, Peter S.

    2011-01-01

    To measure the exposure to self-induced tissue vibration in speech, three vocal doses were defined and described: distance dose, which accumulates the distance that tissue particles of the vocal folds travel in an oscillatory trajectory; energy dissipation dose, which accumulates the total amount of heat dissipated over a unit volume of vocal fold tissues; and time dose, which accumulates the total phonation time. These doses were compared to a previously used vocal dose measure, the vocal loading index, which accumulates the number of vibration cycles of the vocal folds. Empirical rules for viscosity and vocal fold deformation were used to calculate all the doses from the fundamental frequency (F0) and sound pressure level (SPL) values of speech. Six participants were asked to read in normal, monotone, and exaggerated speech and the doses associated with these vocalizations were calculated. The results showed that large F0 and SPL variations in speech affected the dose measures, suggesting that accumulation of phonation time alone is insufficient. The vibration exposure of the vocal folds in normal speech was related to the industrial limits for hand-transmitted vibration, in which the safe distance dose was derived to be about 500 m. This limit was found rather low for vocalization; it was related to a comparable time dose of about 17 min of continuous vocalization, or about 35 min of continuous reading with normal breathing and unvoiced segments. The voicing pauses in normal speech and dialogue effectively prolong the safe time dose. The derived safety limits for vocalization will likely require refinement based on a more detailed knowledge of the differences in hand and vocal fold tissue morphology and their response to vibrational stress, and on the effect of recovery of the vocal fold tissue during voicing pauses. PMID:12959470

  6. Vocal dose measures: quantifying accumulated vibration exposure in vocal fold tissues.

    PubMed

    Titze, Ingo R; Svec, Jan G; Popolo, Peter S

    2003-08-01

    To measure the exposure to self-induced tissue vibration in speech, three vocal doses were defined and described: distance dose, which accumulates the distance that tissue particles of the vocal folds travel in an oscillatory trajectory; energy dissipation dose, which accumulates the total amount of heat dissipated over a unit volume of vocal fold tissues; and time dose, which accumulates the total phonation time. These doses were compared to a previously used vocal dose measure, the vocal loading index, which accumulates the number of vibration cycles of the vocal folds. Empirical rules for viscosity and vocal fold deformation were used to calculate all the doses from the fundamental frequency (F0) and sound pressure level (SPL) values of speech. Six participants were asked to read in normal, monotone, and exaggerated speech and the doses associated with these vocalizations were calculated. The results showed that large F0 and SPL variations in speech affected the dose measures, suggesting that accumulation of phonation time alone is insufficient. The vibration exposure of the vocal folds in normal speech was related to the industrial limits for hand-transmitted vibration, in which the safe distance dose was derived to be about 500 m. This limit was found rather low for vocalization; it was related to a comparable time dose of about 17 min of continuous vocalization, or about 35 min of continuous reading with normal breathing and unvoiced segments. The voicing pauses in normal speech and dialogue effectively prolong the safe time dose. The derived safety limits for vocalization will likely require refinement based on a more detailed knowledge of the differences in hand and vocal fold tissue morphology and their response to vibrational stress, and on the effect of recovery of the vocal fold tissue during voicing pauses.

  7. Studies on hand-held visual communication device for the deaf and speech-impaired 2. Keyboard design.

    PubMed

    Thurlow, W R

    1980-01-01

    Experiments with keyboard arrangements of letters show that simple alphabetic letter-key sequences with 4 to 5 letters in a row lead to most rapid visual search performance. Such arrangements can be used on keyboards operated by the index finger of one hand. Arrangement of letters in words offers a promising alternative because these arrangements can be readily memorized and can result in small interletter distances on the keyboard for frequently occurring letter sequences. Experiments on operation of keyboards show that a space or shift key operated by the left hand (which also holds the communication device) results in faster keyboard operation than when space or shift keys on the front of the keyboard (operated by right hand) are used. Special problems of the deaf-blind are discussed. Keyboard arrangements are investigated, and matching tactual codes are suggested.

  8. Investigations into the efficacy of different procedures for surgical hand disinfection between consecutive operations.

    PubMed

    Rehork, B; Rüden, H

    1991-10-01

    In order to examine whether thorough surgical hand disinfection (handwashing plus hand disinfection) between consecutive operations is necessary, tests were carried out simulating normal clinical conditions. The tests were performed according to the guidelines for the evaluation of disinfection procedures of the German Society for Hygiene and Microbiology. Surgical hand disinfection was as follows: handwashing with soap without antimicrobial additives and subsequent 5-min disinfection with 60% n-propanol. This was followed by simulated operations of 30 or 120 min duration with a 30-min break between operations, during which half of the test group kept on the surgical gloves, while the other half removed them. The second surgical hand disinfection was done without prior handwashing by 50% of the test group. The disinfection time was reduced from 5 to 1 min by 50% of the test group. The results were evaluated by means of explorative data analysis and inductive statistical methods. Removing the surgical gloves during the interoperative break did not result in significantly higher numbers of colony forming units (cfu) compared with retaining the gloves. This was also the case after a subsequent handwashing. At the second surgical hand disinfection, after a simulated operation of 60 min duration (including break), there was no significant difference in the numbers of cfus between the test group who had washed their hands and those who had not. Reducing the disinfection time from 5 min to 1 min was not associated with a significant increase in the number of cfus. However, after a simulated operating time of 150 min (including the break), the second surgical hand disinfection with handwashing resulted in a significantly lower number of microorganisms than disinfection alone. In half the tests, the numbers of cfu were significantly lower when the test group disinfected their hands for 5 min rather than 1 min.

  9. Radiation exposure to operator and patients during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures

    NASA Astrophysics Data System (ADS)

    Lee, C. H.; Cho, J. H.; Park, S. J.; Kim, J. S.; On, Y. K.; Huh, J.

    2015-10-01

    The purpose of this study was to measure the radiation exposure to operator and patient during cardiac electrophysiology study, radiofrequency catheter ablation and cardiac device implantation procedures and to calculate the allowable number of cases per year. We carried out 9 electrophysiology studies, 40 radiofrequency catheter ablation and 11 cardiac device implantation procedures. To measure occupational radiation dose and dose-area product (DAP), 13 photoluminescence glass dosimeters were placed at eyes (inside and outside lead glass), thyroids (inside and outside thyroid collar), chest (inside and outside lead apron), wrists, genital of the operator (inside lead apron), and 6 of photoluminescence glass dosimeters were placed at eyes, thyroids, chest and genital of the patient. Exposure time and DAP values were 11.7 ± 11.8 min and 23.2 ± 26.2 Gy cm2 for electrophysiology study; 36.5 ± 42.1 min and 822.4 ± 125.5 Gy cm2 for radiofrequency catheter ablation; 16.2 ± 9.3 min and 27.8 ± 16.5 Gy cm2 for cardiac device implantation procedure, prospectively. 4591 electrophysiology studies can be conducted within the occupational exposure limit for the eyes (150 mSv), and 658-electrophysiology studies with radiofrequency catheter ablation can be carried out within the occupational exposure limit for the hands (500 mSv). 1654 cardiac device implantation procedure can be conducted within the occupational exposure limit for the eyes (150 mSv). The amounts of the operator and patient's radiation exposure were comparatively small. So, electrophysiology study, radio frequency catheter ablation and cardiac device implantation procedures are safe when performed with modern equipment and optimized protective radiation protect equipment.

  10. SU-E-E-05: Initial Experience On Physics Rotation of Radiological Residents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, J; Williams, D; DiSantis, D

    Purpose: The new ABR core exam integrates physics into clinical teaching, with an emphasis on understanding image quality, image artifacts, radiation dose and patient safety for each modality and/or sub-specialty. Accordingly, physics training of radiological residents faces a challenge. A traditional teaching of physics through didactic lectures may not fully fulfill this goal. It is also difficult to incorporate physics teaching in clinical practice due to time constraints. A dedicated physics rotation may be a solution. This study is to evaluate a full week physics workshop developed for the first year radiological residents. Methods: The physics rotation took a fullmore » week. It included three major parts, introduction lectures, hand-on experiences and observation of technologist operation. An introduction of basic concepts was given to each modality at the beginning. Hand-on experiments were emphasized and took most of time. During hand-on experiments, residents performed radiation measurements, studied the relationship between patient dose and practice (i.e., fluoroscopy), investigated influence of acquisition parameters (i.g., kV, mAs) on image quality, and evaluated image quality using phantoms A physics test before and after the workshop was also given but not for comparison purpose. Results: The evaluation shows that the physics rotation during the first week of residency in radiology is preferred by all residents. The length of a full week of physics workshop is appropriate. All residents think that the intensive workshop can significantly benefit their coming clinical rotations. Residents become more comfortable regarding the use of radiation and counseling relevant questions such as a pregnant patient risk from a CE PE examination. Conclusion: A dedicated physics rotation, assisting with didactic lectures, may fulfill the requirements of physics of the new ABR core exam. It helps radiologists deeply understand the physics concepts and more efficiently use the medical physics in practice.« less

  11. Opportunities to improve the in vivo measurement of manganese in human hands.

    PubMed

    Aslam; Chettle, D R; Pejović-Milić, A; Waker, A J

    2009-01-07

    Manganese (Mn) is an element which is both essential for regulating neurological and skeletal functions in the human body and also toxic when humans are exposed to excessive levels. Its excessive inhalation as a result of exposure through industrial and environmental emissions can cause neurological damage, which may manifest as memory deficit, loss of motor control and reduction in the refinement of certain body motions. A number of clinical studies demonstrate that biological monitoring of Mn exposure using body fluids, particularly blood, plasma/serum and urine is of very limited use and reflect only the most recent exposure and rapidly return to within normal ranges. In this context, a non-invasive neutron activation technique has been developed at the McMaster University accelerator laboratory that could provide an alternative to measure manganese stored in the bones of exposed subjects. In a first pilot study we conducted recently on non-exposed human subjects to measure the ratio of Mn to Ca in hand bones, it was determined that the technique needed further development to improve the precision of the measurements. It could be achieved by improving the minimum detection limit (MDL) of the system from 2.1 microg Mn/g Ca to the reference value of 0.6 microg g(-1) Ca (range: 0.16-0.78 microg Mn/g Ca) for the non-exposed population. However, the developed procedure might still be a suitable means of screening patients and people exposed to excessive amounts of Mn, who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. To improve the MDL of the technique to the expected levels of Mn in a reference population, the present study investigates further optimization of irradiation conditions, which includes the optimal selection of proton beam energy, beam current and irradiation time and the effect of upgrading the 4pi detection system. The maximum local dose equivalent that could be given to the hand as a result of irradiation was constrained to be less than 150 mSv as opposed to the previously imposed dose equivalent limit of 20 mSv. A maximum beam current, which could be delivered on the lithium target to produce neutrons, was restricted to 500 microA. The length of irradiation intervals larger than 10 min, was considered inconvenient and impractical to implement with Mn measurements in humans. To fulfil the requirements for developing a protocol for in vivo bone Mn measurements, a revised estimate of the dose equivalent has been presented here. Beam energy of 1.98 MeV was determined to be optimal to complete the irradiation procedure within 10 min using 500 microA beam current. The local dose equivalent given to hand was estimated as 118 mSv, which is lower by a factor of 1.5 compared to that of 2.00 MeV. The optimized beam parameters are expected to improve the currently obtained detection limit of 2.1 microg Mn/g Ca to 0.6 microg Mn/g Ca. Using this dose equivalent delivered to the central location of the hand, the average dose equivalent to the hand of 74 mSv and an effective dose of approximately 70 microSv will be accompanying the non-invasive, in vivo measurements of bone Mn, which is little over the chest radiograph examination dose.

  12. Opportunities to improve the in vivo measurement of manganese in human hands

    NASA Astrophysics Data System (ADS)

    Aslam; Chettle, D. R.; Pejović-Milić, A.; Waker, A. J.

    2009-01-01

    Manganese (Mn) is an element which is both essential for regulating neurological and skeletal functions in the human body and also toxic when humans are exposed to excessive levels. Its excessive inhalation as a result of exposure through industrial and environmental emissions can cause neurological damage, which may manifest as memory deficit, loss of motor control and reduction in the refinement of certain body motions. A number of clinical studies demonstrate that biological monitoring of Mn exposure using body fluids, particularly blood, plasma/serum and urine is of very limited use and reflect only the most recent exposure and rapidly return to within normal ranges. In this context, a non-invasive neutron activation technique has been developed at the McMaster University accelerator laboratory that could provide an alternative to measure manganese stored in the bones of exposed subjects. In a first pilot study we conducted recently on non-exposed human subjects to measure the ratio of Mn to Ca in hand bones, it was determined that the technique needed further development to improve the precision of the measurements. It could be achieved by improving the minimum detection limit (MDL) of the system from 2.1 µg Mn/g Ca to the reference value of 0.6 µg g-1 Ca (range: 0.16-0.78 µg Mn/g Ca) for the non-exposed population. However, the developed procedure might still be a suitable means of screening patients and people exposed to excessive amounts of Mn, who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. To improve the MDL of the technique to the expected levels of Mn in a reference population, the present study investigates further optimization of irradiation conditions, which includes the optimal selection of proton beam energy, beam current and irradiation time and the effect of upgrading the 4π detection system. The maximum local dose equivalent that could be given to the hand as a result of irradiation was constrained to be less than 150 mSv as opposed to the previously imposed dose equivalent limit of 20 mSv. A maximum beam current, which could be delivered on the lithium target to produce neutrons, was restricted to 500 µA. The length of irradiation intervals larger than 10 min, was considered inconvenient and impractical to implement with Mn measurements in humans. To fulfil the requirements for developing a protocol for in vivo bone Mn measurements, a revised estimate of the dose equivalent has been presented here. Beam energy of 1.98 MeV was determined to be optimal to complete the irradiation procedure within 10 min using 500 µA beam current. The local dose equivalent given to hand was estimated as 118 mSv, which is lower by a factor of 1.5 compared to that of 2.00 MeV. The optimized beam parameters are expected to improve the currently obtained detection limit of 2.1 µg Mn/g Ca to 0.6 µg Mn/g Ca. Using this dose equivalent delivered to the central location of the hand, the average dose equivalent to the hand of 74 mSv and an effective dose of approximately 70 µSv will be accompanying the non-invasive, in vivo measurements of bone Mn, which is little over the chest radiograph examination dose.

  13. Excimer laser therapy and narrowband ultraviolet B therapy for exfoliative cheilitis.

    PubMed

    Bhatia, Bhavnit K; Bahr, Brooks A; Murase, Jenny E

    2015-06-01

    Exfoliative cheilitis is a condition of unknown etiology characterized by hyperkeratosis and scaling of vermilion epithelium with cyclic desquamation. It remains largely refractory to treatment, including corticosteroid therapy, antibiotics, antifungals, and immunosuppressants. We sought to evaluate the safety and efficacy of excimer laser therapy and narrowband ultraviolet B therapy in female patients with refractory exfoliative cheilitis. We reviewed the medical records of two female patients who had been treated unsuccessfully for exfoliative cheilitis. We implemented excimer laser therapy, followed by hand-held narrowband UVB treatments for maintenance therapy, and followed them for clinical improvement and adverse effects. Both patients experienced significant clinical improvement with minimal adverse effects with excimer laser therapy 600-700 mJ/cm 2 twice weekly for several months. The most common adverse effects were bleeding and burning, which occurred at higher doses. The hand-held narrowband UVB unit was also an effective maintenance tool. Limitations include small sample size and lack of standardization of starting dose and dose increments. Excimer laser therapy is a well-tolerated and effective treatment for refractory exfoliative cheilitis with twice weekly laser treatments of up to 700 mJ/cm 2 . Transitioning to the hand-held narrowband UVB device was also an effective maintenance strategy.

  14. Second hand smoke and risk assessment: what was in it for the tobacco industry?

    PubMed Central

    Hirschhorn, N.; Bialous, S. A.

    2001-01-01

    OBJECTIVE—To describe how the tobacco industry attempted to trivialise the health risks of second hand smoke (SHS) by both questioning the science of risk assessment of low dose exposure to other environmental toxins, and by comparing SHS to such substances about which debate might still exist.
METHODS—Analysis of tobacco industry documents made public as part of the settlement of litigation in the USA (Minnesota trial and the Master Settlement Agreement) and available on the internet. Search terms included: risk assessment, low dose exposure, and the names of key players and organisations.
RESULTS/CONCLUSION—The tobacco industry developed a well coordinated, multi-pronged strategy to create doubt about research on exposure to SHS by trying to link it to the broader discussion of risk assessment of low doses of a number of toxins whose disease burden may still be a matter of scientific debate, thus trying to make SHS their equivalent; and by attempting, through third party organisations and persons, to impugn the agencies using risk assessment to establish SHS as a hazard.


Keywords: tobacco industry; risk assessment; environmental tobacco smoke; ETS; second hand smoke; SHS PMID:11740031

  15. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Devic, S; Tomic, N; DeBlois, F

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response bymore » using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.« less

  16. Empirical model for conveniently predicting total and regional lung deposition of inhaled aerosols

    EPA Science Inventory

    Accurate estimate of a dose of inhaled aerosols is a key factor for estimating potential health risks to exposure to ambient pollutant particulate matter on the one hand, and the therapeutic efficacy of inhaled drug aerosols on the other hand. Particle deposition in the lung is d...

  17. [The evaluation of the consequences of electromagnetic irradiation of hands in operators of high-frequency welding devices].

    PubMed

    Rudakov, M L

    2000-01-01

    Method of secondary sources (method of integral equations) was applied to calculate specific absorbed intensity in hands of operators working at non-shielded high-frequency (27.12 Mhz) welding devices. The authors present calculations for "female" and "male" hand sizes, give recommendations on lower level of specific absorption.

  18. Developing a virtual reality application for training nuclear power plant operators: setting up a database containing dose rates in the refuelling plant.

    PubMed

    Ródenas, J; Zarza, I; Burgos, M C; Felipe, A; Sánchez-Mayoral, M L

    2004-01-01

    Operators in Nuclear Power Plants can receive high doses during refuelling operations. A training programme for simulating refuelling operations will be useful in reducing the doses received by workers as well as minimising operation time. With this goal in mind, a virtual reality application is developed within the framework of the CIPRES project. The application requires doses, both instantaneous and accumulated, to be displayed at all times during operator training. Therefore, it is necessary to set up a database containing dose rates at every point in the refuelling plant. This database is based on radiological protection surveillance data measured in the plant during refuelling operations. Some interpolation routines have been used to estimate doses through the refuelling plant. Different assumptions have been adopted in order to perform the interpolation and obtain consistent data. In this paper, the procedures developed to set up the dose database for the virtual reality application are presented and analysed.

  19. Classification of radiation effects for dose limitation purposes: history, current situation and future prospects

    PubMed Central

    Hamada, Nobuyuki; Fujimichi, Yuki

    2014-01-01

    Radiation exposure causes cancer and non-cancer health effects, each of which differs greatly in the shape of the dose–response curve, latency, persistency, recurrence, curability, fatality and impact on quality of life. In recent decades, for dose limitation purposes, the International Commission on Radiological Protection has divided such diverse effects into tissue reactions (formerly termed non-stochastic and deterministic effects) and stochastic effects. On the one hand, effective dose limits aim to reduce the risks of stochastic effects (cancer/heritable effects) and are based on the detriment-adjusted nominal risk coefficients, assuming a linear-non-threshold dose response and a dose and dose rate effectiveness factor of 2. On the other hand, equivalent dose limits aim to avoid tissue reactions (vision-impairing cataracts and cosmetically unacceptable non-cancer skin changes) and are based on a threshold dose. However, the boundary between these two categories is becoming vague. Thus, we review the changes in radiation effect classification, dose limitation concepts, and the definition of detriment and threshold. Then, the current situation is overviewed focusing on (i) stochastic effects with a threshold, (ii) tissue reactions without a threshold, (iii) target organs/tissues for circulatory disease, (iv) dose levels for limitation of cancer risks vs prevention of non-life-threatening tissue reactions vs prevention of life-threatening tissue reactions, (v) mortality or incidence of thyroid cancer, and (vi) the detriment for tissue reactions. For future discussion, one approach is suggested that classifies radiation effects according to whether effects are life threatening, and radiobiological research needs are also briefly discussed. PMID:24794798

  20. Hand trauma: A prospective observational study reporting diagnostic concordance in emergency hand trauma which supports centralised service improvements.

    PubMed

    Miranda, B H; Spilsbury, Z P; Rosala-Hallas, A; Cerovac, S

    2016-10-01

    Hand injuries are common, contributing up to 30% of accident and emergency (A&E) attendances. The aim of this study was to prospectively analyse the pathological demographics of hand injuries in a level 1 trauma centre with a Hand Trauma Unit and direct A&E links, and compare clinical and intra-operative findings. The null hypothesis was that there would be no differences between clinical and intra-operative findings (100% diagnostic concordance). Data were prospectively collected for referrals during 2012. Referral diagnosis, additional pathologies found on clinical assessment and intra-operative findings were documented on a live database accessible from both the Hand Unit and associated operating theatres. Odds ratios were calculated using SAS. Injuries (1526) were identified in 1308 patients included in the study. Diagnostic concordance between Hand Unit clinical examination and intra-operative findings was 92.5% ± 2.85% (mean ± SEM); this was lower for flexor tendon injuries (56.3%) because a greater number of additional pathologies were found intra-operatively (2.25 ± 0.10). This 'trend' was noted across multiple referral pathologies including phalangeal fractures (1.28 ± 0.02; 82.9%), lacerations (1.33 ± 0.04; 79.1%), extensor tendon injuries (1.30 ± 0.05; 87.8%) and dislocations (1.18 ± 0.05; 87.8%). Odds ratio analysis indicated a relationship between primary referral diagnoses that were more or less likely to be associated with additional injuries (p < 0.05); referral diagnoses of flexor tendon injuries and lacerations were most likely to be associated with additional injuries. As hand injuries are a common presentation to A&E departments, greater emphasis should be placed on training clinicians in the management of hand trauma. Our findings, coupled with the presented relevant literature reports, lead us to advocate that A&E departments should move towards a system wherein links to specialist hand trauma services are in place; we hereby present useful data for hospitals implementing such services. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  1. SUDOQU, a new dose-assessment methodology for radiological surface contamination.

    PubMed

    van Dillen, Teun; van Dijk, Arjan

    2018-06-12

    A new methodology has been developed for the assessment of the annual effective dose resulting from removable and fixed radiological surface contamination. It is entitled SUDOQU (SUrface DOse QUantification) and it can for instance be used to derive criteria for surface contamination related to the import of non-food consumer goods, containers and conveyances, e.g., limiting values and operational screening levels. SUDOQU imposes mass (activity)-balance equations based on radioactive decay, removal and deposition processes in indoor and outdoor environments. This leads to time-dependent contamination levels that may be of particular importance in exposure scenarios dealing with one or a few contaminated items only (usually public exposure scenarios, therefore referred to as the 'consumer' model). Exposure scenarios with a continuous flow of freshly contaminated goods also fall within the scope of the methodology (typically occupational exposure scenarios, thus referred to as the 'worker model'). In this paper we describe SUDOQU, its applications, and its current limitations. First, we delineate the contamination issue, present the assumptions and explain the concepts. We describe the relevant removal, transfer, and deposition processes, and derive equations for the time evolution of the radiological surface-, air- and skin-contamination levels. These are then input for the subsequent evaluation of the annual effective dose with possible contributions from external gamma radiation, inhalation, secondary ingestion (indirect, from hand to mouth), skin contamination, direct ingestion and skin-contact exposure. The limiting effective surface dose is introduced for issues involving the conservatism of dose calculations. SUDOQU can be used by radiation-protection scientists/experts and policy makers in the field of e.g. emergency preparedness, trade and transport, exemption and clearance, waste management, and nuclear facilities. Several practical examples are worked out demonstrating the potential applications of the methodology. . Creative Commons Attribution license.

  2. Assessment of exposure to pesticides during mixing/loading and spraying of tomatoes in the open field.

    PubMed

    Aprea, Maria Cristina; Bosi, Anna; Manara, Michele; Mazzocchi, Barbara; Pompini, Alessandra; Sormani, Francesca; Lunghini, Liana; Sciarra, Gianfranco

    2016-01-01

    Some evidence of exposure-response of metolachlor and pendimethalin for lung cancer and an association of metribuzin with risk of glioma have been reported. The primary objectives in this study were to evaluate exposure and occupational risk during mixing/loading of pesticides and during their application to tomatoes cultivated in open fields. Sixteen farmers were sampled. Respiratory exposure was estimated by personal air sampling using fiberglass filters in a IOM device. Dermal exposure was assessed using skin pads and hand washing. Absorbed doses were estimated assuming 100% lung retention, and 50% or 10% skin absorption for metribuzin, and pendimethalin and metolachlor, respectively. The three pesticides were quantified by gas chromatography tandem mass spectrometry in all matrices. Metolachlor was used as a tracer of contamination of clothes and tractors unrelated to the exposure monitored. Respiratory exposure to metribuzin, used in granular form, was on average more than one order of magnitude higher than exposure to pendimethalin, used in the form of microencapsulated liquid. The actual doses were 0.067-8.08 µg/kg bw, 0.420-12.6 µg/kg bw, and 0.003-0.877 µg/kg bw for pendimethalin, metribuzin, and metolachlor, respectively. Dermal exposure was about 88% of the actual dose for metribuzin and more than 95%, for pendimethalin and metolachlor. For risk assessment, the total absorbed doses (sum of respiratory and skin absorbed doses) were compared with the AOEL for each compound. The actual and absorbed doses of the three pesticides were always lower than the acceptable operator exposure level (AOEL), which are reported to be 234 µg/kg bw, 20 µg/kg bw, and 150 µg/kg bw for pendimethalin, metribuzin, and metolachlor, respectively. In any case, personal protective equipment and spraying devices should be chosen with care to minimize exposure.

  3. Editor's choice--Use of disposable radiation-absorbing surgical drapes results in significant dose reduction during EVAR procedures.

    PubMed

    Kloeze, C; Klompenhouwer, E G; Brands, P J M; van Sambeek, M R H M; Cuypers, P W M; Teijink, J A W

    2014-03-01

    Because of the increasing number of interventional endovascular procedures with fluoroscopy and the corresponding high annual dose for interventionalists, additional dose-protecting measures are desirable. The purpose of this study was to evaluate the effect of disposable radiation-absorbing surgical drapes in reducing scatter radiation exposure for interventionalists and supporting staff during an endovascular aneurysm repair (EVAR) procedure. This was a randomized control trial in which 36 EVAR procedures were randomized between execution with and without disposable radiation-absorbing surgical drapes (Radpad: Worldwide Innovations & Technologies, Inc., Kansas City, US, type 5511A). Dosimetric measurements were performed on the interventionalist (hand and chest) and theatre nurse (chest) with and without the use of the drapes to obtain the dose reduction and effect on the annual dose caused by the drapes. Use of disposable radiation-absorbing surgical drapes resulted in dose reductions of 49%, 55%, and 48%, respectively, measured on the hand and chest of the interventionalist and the chest of the theatre nurse. The use of disposable radiation-absorbing surgical drapes significantly reduces scatter radiation exposure for both the interventionalist and the supporting staff during EVAR procedures. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  4. New image-processing and noise-reduction software reduces radiation dose during complex endovascular procedures.

    PubMed

    Kirkwood, Melissa L; Guild, Jeffrey B; Arbique, Gary M; Tsai, Shirling; Modrall, J Gregory; Anderson, Jon A; Rectenwald, John; Timaran, Carlos

    2016-11-01

    A new proprietary image-processing system known as AlluraClarity, developed by Philips Healthcare (Best, The Netherlands) for radiation-based interventional procedures, claims to lower radiation dose while preserving image quality using noise-reduction algorithms. This study determined whether the surgeon and patient radiation dose during complex endovascular procedures (CEPs) is decreased after the implementation of this new operating system. Radiation dose to operators, procedure type, reference air kerma, kerma area product, and patient body mass index were recorded during CEPs on two Philips Allura FD 20 fluoroscopy systems with and without Clarity. Operator dose during CEPs was measured using optically stimulable, luminescent nanoDot (Landauer Inc, Glenwood, Ill) detectors placed outside the lead apron at the left upper chest position. nanoDots were read using a microStar ii (Landauer Inc) medical dosimetry system. For the CEPs in the Clarity group, the radiation dose to surgeons was also measured by the DoseAware (Philips Healthcare) personal dosimetry system. Side-by-side measurements of DoseAware and nanoDots allowed for cross-calibration between systems. Operator effective dose was determined using a modified Niklason algorithm. To control for patient size and case complexity, the average fluoroscopy dose rate and the dose per radiographic frame were adjusted for body mass index differences and then compared between the groups with and without Clarity by procedure. Additional factors, for example, physician practice patterns, that may have affected operator dose were inferred by comparing the ratio of the operator dose to procedural kerma area product with and without Clarity. A one-sided Wilcoxon rank sum test was used to compare groups for radiation doses, reference air kermas, and operating practices for each procedure type. The analysis included 234 CEPs; 95 performed without Clarity and 139 with Clarity. Practice patterns of operators during procedures with and without Clarity were not significantly different. For all cases, procedure radiation dose to the patient and the primary and assistant operators were significantly decreased in the Clarity group by 60% compared with the non-Clarity group. By procedure type, fluorography dose rates decreased from 44% for fenestrated endovascular repair and up to 70% with lower extremity interventions. Fluoroscopy dose rates also significantly decreased, from about 37% to 47%, depending on procedure type. The AlluraClarity system reduces the patient and primary operator's radiation dose by more than half during CEPs. This feature appears to be an effective tool in lowering the radiation dose while maintaining image quality. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  5. The Differential Effect of Sustained Operations on Psychomotor Skills of Helicopter Pilots.

    PubMed

    McMahon, Terry W; Newman, David G

    2018-06-01

    Flying a helicopter is a complex psychomotor skill requiring constant control inputs from pilots. A deterioration in psychomotor performance of a helicopter pilot may be detrimental to operational safety. The aim of this study was to test the hypothesis that psychomotor performance deteriorates over time during sustained operations and that the effect is more pronounced in the feet than the hands. The subjects were helicopter pilots conducting sustained multicrew offshore flight operations in a demanding environment. The remote flight operations involved constant workload in hot environmental conditions with complex operational tasking. Over a period of 6 d 10 helicopter pilots were tested. At the completion of daily flying duties, a helicopter-specific screen-based compensatory tracking task measuring tracking accuracy (over a 5-min period) tested both hands and feet. Data were compared over time and tested for statistical significance for both deterioration and differential effect. A statistically significant deterioration of psychomotor performance was evident in the pilots over time for both hands and feet. There was also a statistically significant differential effect between the hands and the feet in terms of tracking accuracy. The hands recorded a 22.6% decrease in tracking accuracy, while the feet recorded a 39.9% decrease in tracking accuracy. The differential effect may be due to prioritization of limb movement by the motor cortex due to factors such as workload-induced cognitive fatigue. This may result in a greater reduction in performance in the feet than the hands, posing a significant risk to operational safety.McMahon TW, Newman DG. The differential effect of sustained operations on psychomotor skills of helicopter pilots. Aerosp Med Hum Perform. 2018; 89(6):496-502.

  6. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... switch. 236.202 Section 236.202 Transportation Other Regulations Relating to Transportation (Continued...-operated switch. Signal governing movements over hand-operated switch in the facing direction shall display... over the switch in the normal and in the reverse position, the signal shall display its most...

  7. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... switch. 236.202 Section 236.202 Transportation Other Regulations Relating to Transportation (Continued...-operated switch. Signal governing movements over hand-operated switch in the facing direction shall display... over the switch in the normal and in the reverse position, the signal shall display its most...

  8. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... switch. 236.202 Section 236.202 Transportation Other Regulations Relating to Transportation (Continued...-operated switch. Signal governing movements over hand-operated switch in the facing direction shall display... over the switch in the normal and in the reverse position, the signal shall display its most...

  9. Hand controllers for teleoperation. A state-of-the-art technology survey and evaluation

    NASA Technical Reports Server (NTRS)

    Brooks, T. L.; Bejczy, A. K.

    1985-01-01

    Hand controller technology for teleoperation is surveyed in three major catagories: (1) hand grip design, (2) control input devices, and (3) control strategies. In the first category, 14 hand grip designs are reviewed and evaluated in light of human factor considerations. In the second, 12 hand controller input devices are evaluated in terms of task performance, configuration and force feedback, controller/slave correspondence, operating volume, operator workload, human limitations, cross coupling, singularities, anthropomorphic characteristics, physical complexity, control/display interference, accuracy, technological base, cost, and reliability. In the third catagory, control strategies, commonly called control modes, are surveyed and evaluated. The report contains a bibliography with 189 select references on hand controller technology.

  10. Dose assessment of 2% chlorhexidine acetate for canine superficial pyoderma.

    PubMed

    Murayama, Nobuo; Terada, Yuri; Okuaki, Mio; Nagata, Masahiko

    2011-10-01

    The dose of 2% chlorhexidine acetate (2CA; Nolvasan(®) Surgical Scrub; Fort Dodge Animal Health, Fort Dodge, IA, USA) for canine superficial pyoderma was evaluated. The first trial compared three doses (group 1, 57 mL/m(2) body surface area; group 2, 29 mL/m(2) body surface area; and group 3, 19 mL/m(2) body surface area) in a randomized, double-blind, controlled fashion. Twenty-seven dogs with superficial pyoderma were treated with 2CA at the allocated doses every 2 days for 1 week. The owners and investigators subjectively evaluated the dogs, and investigators scored skin lesions, including erythema, papules/pustules, alopecia and scales, on a 0-4 scale. There were no significant differences in response between the treatment groups. The second trial established a practical dose-measuring method for 2CA. Sixty-eight owners were asked to apply 2CA on their palm in an amount corresponding to a Japanese ¥500 coin, 26.5 mm in diameter. This yielded an average dose of 0.90±0.40 mL. Mathematically, the doses used in groups 1, 2 and 3 can be represented as one coin per approximately one-, two- and three-hand-sized lesions, respectively. The results therefore suggest that owners instructed to apply one coin of the product per two-hand-sized areas of superficial pyoderma would use the range of doses evaluated in this trial. © 2011 The Authors. Veterinary Dermatology. © 2011 ESVD and ACVD.

  11. One-per-mil tumescent technique for upper extremity surgeries: broadening the indication.

    PubMed

    Prasetyono, Theddeus O H; Biben, Johannes A

    2014-01-01

    We studied the effect of 1:1,000,000 epinephrine concentration (1 per mil) to attain a bloodless operative field in hand and upper extremity surgery and to explore its effectiveness and safety profile. This retrospective observational study enrolled 45 consecutive patients with 63 operative fields consisting of various hand and upper extremity problems. One-per-mil solution was injected into the operative field with tumescent technique to create a bloodless operating field without tourniquet. The solution was formulated by adding a 1:1,000,000 concentration of epinephrine and 100 mg of lidocaine into saline solution to form 50 mL of tumescent solution. Observation was performed on the clarity of the operative field, which we described as totally bloodless, minimal bleeding, acceptable bleeding, or bloody. The volume of tumescent solution injected, duration of surgery, and surgical outcome were also reviewed. The tumescent technique with 1-per-mil solution achieved 29% totally bloodless, 48% minimal bleeding, 22% acceptable bleeding, and 2% bloody operative fields in cases that included burn contracture and congenital hand and upper extremity surgeries. One-per-mil tumescent solution created a clear operative field in hand and upper extremity surgery. It proved safe and effective for a wide range of indications. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Vision-Based Pose Estimation for Robot-Mediated Hand Telerehabilitation.

    PubMed

    Airò Farulla, Giuseppe; Pianu, Daniele; Cempini, Marco; Cortese, Mario; Russo, Ludovico O; Indaco, Marco; Nerino, Roberto; Chimienti, Antonio; Oddo, Calogero M; Vitiello, Nicola

    2016-02-05

    Vision-based Pose Estimation (VPE) represents a non-invasive solution to allow a smooth and natural interaction between a human user and a robotic system, without requiring complex calibration procedures. Moreover, VPE interfaces are gaining momentum as they are highly intuitive, such that they can be used from untrained personnel (e.g., a generic caregiver) even in delicate tasks as rehabilitation exercises. In this paper, we present a novel master-slave setup for hand telerehabilitation with an intuitive and simple interface for remote control of a wearable hand exoskeleton, named HX. While performing rehabilitative exercises, the master unit evaluates the 3D position of a human operator's hand joints in real-time using only a RGB-D camera, and commands remotely the slave exoskeleton. Within the slave unit, the exoskeleton replicates hand movements and an external grip sensor records interaction forces, that are fed back to the operator-therapist, allowing a direct real-time assessment of the rehabilitative task. Experimental data collected with an operator and six volunteers are provided to show the feasibility of the proposed system and its performances. The results demonstrate that, leveraging on our system, the operator was able to directly control volunteers' hands movements.

  13. The study of in vivo quantification of aluminum (Al) in human bone with a compact DD generator-based neutron activation analysis (NAA) system.

    PubMed

    Byrne, Patrick; Mostafaei, Farshad; Liu, Yingzi; Blake, Scott P; Koltick, David; Nie, Linda H

    2016-05-01

    The feasibility and methodology of using a compact DD generator-based neutron activation analysis system to measure aluminum in hand bone has been investigated. Monte Carlo simulations were used to simulate the moderator, reflector, and shielding assembly and to estimate the radiation dose. A high purity germanium (HPGe) detector was used to detect the Al gamma ray signals. The minimum detectable limit (MDL) was found to be 11.13 μg g(-1) dry bone (ppm). An additional HPGe detector would improve the MDL by a factor of 1.4, to 7.9 ppm. The equivalent dose delivered to the irradiated hand was calculated by Monte Carlo to be 11.9 mSv. In vivo bone aluminum measurement with the DD generator was found to be feasible among general population with an acceptable dose to the subject.

  14. Ground Robotic Hand Applications for the Space Program study (GRASP)

    NASA Astrophysics Data System (ADS)

    Grissom, William A.; Rafla, Nader I.

    1992-04-01

    This document reports on a NASA-STDP effort to address research interests of the NASA Kennedy Space Center (KSC) through a study entitled, Ground Robotic-Hand Applications for the Space Program (GRASP). The primary objective of the GRASP study was to identify beneficial applications of specialized end-effectors and robotic hand devices for automating any ground operations which are performed at the Kennedy Space Center. Thus, operations for expendable vehicles, the Space Shuttle and its components, and all payloads were included in the study. Typical benefits of automating operations, or augmenting human operators performing physical tasks, include: reduced costs; enhanced safety and reliability; and reduced processing turnaround time.

  15. Ground Robotic Hand Applications for the Space Program study (GRASP)

    NASA Technical Reports Server (NTRS)

    Grissom, William A.; Rafla, Nader I. (Editor)

    1992-01-01

    This document reports on a NASA-STDP effort to address research interests of the NASA Kennedy Space Center (KSC) through a study entitled, Ground Robotic-Hand Applications for the Space Program (GRASP). The primary objective of the GRASP study was to identify beneficial applications of specialized end-effectors and robotic hand devices for automating any ground operations which are performed at the Kennedy Space Center. Thus, operations for expendable vehicles, the Space Shuttle and its components, and all payloads were included in the study. Typical benefits of automating operations, or augmenting human operators performing physical tasks, include: reduced costs; enhanced safety and reliability; and reduced processing turnaround time.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cazzato, Roberto Luigi, E-mail: gigicazzato@hotmail.it; Garnon, Julien, E-mail: juleiengarnon@gmail.com; Ramamurthy, Nitin, E-mail: nitin-ramamurthy@hotmail.com

    AimTo review our preliminary experience with 6-l-18F-fluorodihydroxyphenylalanine (18F-FDOPA) PET/CT-guided radiofrequency ablation (RFA) of liver metastases from neuroendocrine tumours (NETs).Materials and MethodsThree patients (mean age 51.3 years; range 43–56) with gastro-entero pancreatic NET (GEP-NET) liver metastases underwent 18F-FDOPA PET/CT-guided RFA. Patients were referred with oligometastatic hepatic-confined disease (1–6 metastases; <3 cm) on 18F-FDOPA PET/CT; poor lesion visualisation on US, CT, and MR; and ongoing symptoms. Procedures were performed in an interventional PET/CT scanner under general anaesthesia using a split-dose protocol. Lesion characteristics, procedural duration and technical success (accurate probe placement and post-procedural ablation-zone photopaenia), complications, patient and operator dose, and clinical outcomes weremore » evaluated.ResultsThirteen liver metastases (mean size 11.4 mm, range 8–16) were treated in three patients (two presented with “carcinoid syndrome”). Technical success was 100 % with a mean procedural duration of 173.3 min (range 90–210) and no immediate complications. Mean patient dose was 2844 mGy·cm (range 2104–3686). Operator and radiographer doses were acceptable other than the operator’s right hand in the first case (149 µSv); this normalised in the second case. There was no local tumour or extra-hepatic disease progression at mid-term follow-up (mean 12.6 months; range 6–20); however, two cases progressed with new liver metastases at different sites. There was 100 % clinical success (n = 2) in resolving carcinoid syndrome symptoms.Conclusion18F-FDOPA PET/CT-guided RFA appears technically feasible, safe, and effective in patients with GEP-NETs and low-burden hepatic metastases. Further prospective studies are required to elucidate its precise role in tailored multimodality management of GEP-NET liver metastases.« less

  17. Variable Operative Experience in Hand Surgery for Plastic Surgery Residents.

    PubMed

    Silvestre, Jason; Lin, Ines C; Levin, Lawrence Scott; Chang, Benjamin

    Efforts to standardize hand surgery training during plastic surgery residency remain challenging. We analyze the variability of operative hand experience at U.S. plastic surgery residency programs. Operative case logs of chief residents in accredited U.S. plastic surgery residency programs were analyzed (2011-2015). Trends in fold differences of hand surgery case volume between the 10th and 90th percentiles of residents were assessed graphically. Percentile data were used to calculate the number of residents achieving case minimums in hand surgery for 2015. Case logs from 818 plastic surgery residents were analyzed of which a minority were from integrated (35.7%) versus independent/combined (64.3%) residents. Trend analysis of fold differences in case volume demonstrated decreasing variability among procedure categories over time. By 2015, fold differences for hand reconstruction, tendon cases, nerve cases, arthroplasty/arthrodesis, amputation, arterial repair, Dupuytren release, and neoplasm cases were below 10-fold. Congenital deformity cases among independent/combined residents was the sole category that exceeded 10-fold by 2015. Percentile data suggested that approximately 10% of independent/combined residents did not meet case minimums for arterial repair and congenital deformity in 2015. Variable operative experience during plastic surgery residency may limit adequate exposure to hand surgery for certain residents. Future studies should establish empiric case minimums for plastic surgery residents to ensure hand surgery competency upon graduation. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Humanlike robot hands controlled by brain activity arouse illusion of ownership in operators

    PubMed Central

    Alimardani, Maryam; Nishio, Shuichi; Ishiguro, Hiroshi

    2013-01-01

    Operators of a pair of robotic hands report ownership for those hands when they hold image of a grasp motion and watch the robot perform it. We present a novel body ownership illusion that is induced by merely watching and controlling robot's motions through a brain machine interface. In past studies, body ownership illusions were induced by correlation of such sensory inputs as vision, touch and proprioception. However, in the presented illusion none of the mentioned sensations are integrated except vision. Our results show that during BMI-operation of robotic hands, the interaction between motor commands and visual feedback of the intended motions is adequate to incorporate the non-body limbs into one's own body. Our discussion focuses on the role of proprioceptive information in the mechanism of agency-driven illusions. We believe that our findings will contribute to improvement of tele-presence systems in which operators incorporate BMI-operated robots into their body representations. PMID:23928891

  19. Decreased Radiation Exposure and Increased Efficacy in Extracorporeal Lithotripsy Using a New Ultrasound Stone Locking System.

    PubMed

    Abid, Nadia; Ravier, Emmanuel; Promeyrat, Xavier; Codas, Ricardo; Fehri, Hakim Fassi; Crouzet, Sebastien; Martin, Xavier

    2015-11-01

    To compare fluoroscopy duration, radiation dose, and efficacy of two ultrasound stone localization systems during extracorporeal shockwave lithotripsy (SWL) treatment. Monocentric prospective data were obtained from patients consecutively treated for renal stones using the Sonolith(®) i-sys (EDAP TMS) lithotripter, with fluoroscopy combined with ultrasound localization using an "outline" Automatic Ultrasound Positioning Support (AUPS) (group A), or the "free-line" Visio-Track (VT) (EDAP-TMS) hand-held three-dimensional ultrasound stone locking system (group B). Efficacy rate was defined as the within-groups proportion stone free or with partial stone fragmentation not needing additional procedures. Statistical analysis used Pearson chi-square tests for categoric variables, nonparametric Mann-Whitney tests for continuous variables, and linear regression for operator learning curve with VT. Continuous variables were reported as median (range) values. Patients in group A (n=73) and group B (n=81) were comparable in baseline characteristics (age, kidney stone size, others) and in SWL application (duration, number of shocks, energy [Joules]). During SWL, the median (range) duration (seconds) of radiation exposure was 159.5 (0-690) in group A and 3.5 (0-478) in group B (P<0.001) and irradiation dose (mGy.cm(2)), 10598 (0-54843) in group A and 163 (0-13926) in group B (P<0.001). Fluoroscopy time significantly decreased with operator experience using VT. The efficacy rate was 54.5% in group A and 79.5% in group B (P=0.001). VT significantly reduced fluoroscopy use during SWL and the duration and dose of patient exposure to ionizing radiation. Stone treatment efficacy was significantly greater with VT mainly because of a better real-time monitoring of the stone.

  20. Development of an image operation system with a motion sensor in dental radiology.

    PubMed

    Sato, Mitsuru; Ogura, Toshihiro; Yasumoto, Yoshiaki; Kadowaki, Yuta; Hayashi, Norio; Doi, Kunio

    2015-07-01

    During examinations and/or treatment, a dentist in the examination room needs to view images with a proper display system. However, they cannot operate the image display system by hands, because dentists always wear gloves to be kept their hands away from unsanitized materials. Therefore, we developed a new image operating system that uses a motion sensor. We used the Leap motion sensor technique to read the hand movements of a dentist. We programmed the system using C++ to enable various movements of the display system, i.e., click, double click, drag, and drop. Thus, dentists with their gloves on in the examination room can control dental and panoramic images on the image display system intuitively and quickly with movement of their hands only. We investigated the time required with the conventional method using a mouse and with the new method using the finger operation. The average operation time with the finger method was significantly shorter than that with the mouse method. This motion sensor method, with appropriate training for finger movements, can provide a better operating performance than the conventional mouse method.

  1. Hand and body radiation exposure with the use of mini C-arm fluoroscopy.

    PubMed

    Tuohy, Christopher J; Weikert, Douglas R; Watson, Jeffry T; Lee, Donald H

    2011-04-01

    To determine whole body and hand radiation exposure to the hand surgeon wearing a lead apron during routine intraoperative use of the mini C-arm fluoroscope. Four surgeons (3 hand attending surgeons and 1 hand fellow) monitored their radiation exposure for a total of 200 consecutive cases (50 cases per surgeon) requiring mini C-arm fluoroscopy. Each surgeon measured radiation exposure with a badge dosimeter placed on the outside breast pocket of the lead apron (external whole body exposure), a second badge dosimeter under the lead apron (shielded whole body exposure), and a ring dosimeter (hand exposure). Completed records were noted in 198 cases, with an average fluoroscopy time of 133.52 seconds and average cumulative dose of 19,260 rem-cm(2) per case. The total measured radiation exposures for the (1) external whole body exposure dosimeters were 16 mrem (for shallow depth), 7 mrem (for eye depth), and less than 1 mrem (for deep depth); (2) shielded whole body badge dosimeters recorded less than 1 mrem; and (3) ring dosimeters totaled 170 mrem. The total radial exposure for 4 ring dosimeters that had registered a threshold of 30 mrem or more of radiation exposure was 170 mrem at the skin level, for an average of 42.5 mrem per dosimeter ring or 6.3 mrem per case. This study of whole body and hand radiation exposure from the mini C-arm includes the largest number of surgical cases in the published literature. The measured whole body and hand radiation exposure received by the hand surgeon from the mini C-arm represents a minimal risk of radiation, based on the current National Council on Radiation Protection and Management standards of annual dose limits (5,000 mrem per year for whole body and 50,000 mrem per year to the extremities). Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. [The surgeon as a hand patient: the clinical and psychological impact of hand and wrist fractures].

    PubMed

    Chin, K R; Lonner, J H; Jupiter, B S; Jupiter, J B

    2010-03-01

    To gain insight into the management of patients with hand and wrist injuries, a series of clinical and psychological analyses was performed on 9 surgeons, each of whom underwent operative fixation of a hand or wrist fracture. The results of these analyses suggest that the functional outcome after hand surgery was affected by the surgeons' personality, motivation, and ability to accept and adapt to the injury, the nature of the injury, and the importance of the hand to the surgeons' careers. Surgeons are highly motivated and compulsive individuals who consider their career involvement a major source of identity and self-worth. Most returned to their operative duties ahead of the schedule set by their hand surgeons (average, 25 days after surgery), regarded their injuries as a positive challenge, and changed their lifestyles after injury to protect their hands.

  3. Targeting MRS-Defined Dominant Intraprostatic Lesions with Inverse-Planned High Dose Rate Brachytherapy

    DTIC Science & Technology

    2007-02-01

    bladder and the rectum are overprotected while the PTV coverage is undesirably reduced. On the other hand, if their maximum dose is increased and/or...B, the bladder and rectum were overprotected with undesirably low PTV coverage (84.54%). The reduction of their weighting factor increased PTV

  4. SU-E-T-24: A Simple Correction-Based Method for Independent Monitor Unit (MU) Verification in Monte Carlo (MC) Lung SBRT Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, D; Badkul, R; Jiang, H

    2014-06-01

    Purpose: Lung-SBRT uses hypo-fractionated dose in small non-IMRT fields with tissue-heterogeneity corrected plans. An independent MU verification is mandatory for safe and effective delivery of the treatment plan. This report compares planned MU obtained from iPlan-XVM-Calgorithm against spreadsheet-based hand-calculation using most commonly used simple TMR-based method. Methods: Treatment plans of 15 patients who underwent for MC-based lung-SBRT to 50Gy in 5 fractions for PTV V100%=95% were studied. ITV was delineated on MIP images based on 4D-CT scans. PTVs(ITV+5mm margins) ranged from 10.1- 106.5cc(average=48.6cc). MC-SBRT plans were generated using a combination of non-coplanar conformal arcs/beams using iPlan XVM-Calgorithm (BrainLAB iPlan ver.4.1.2)more » for Novalis-TX consisting of micro-MLCs and 6MV-SRS (1000MU/min) beam. These plans were re-computed using heterogeneity-corrected Pencil-Beam (PB-hete) algorithm without changing any beam parameters, such as MLCs/MUs. Dose-ratio: PB-hete/MC gave beam-by-beam inhomogeneity-correction-factors (ICFs):Individual Correction. For independent-2nd-check, MC-MUs were verified using TMR-based hand-calculation and obtained an average ICF:Average Correction, whereas TMR-based hand-calculation systematically underestimated MC-MUs by ∼5%. Also, first 10 MC-plans were verified with an ion-chamber measurement using homogenous phantom. Results: For both beams/arcs, mean PB-hete dose was systematically overestimated by 5.5±2.6% and mean hand-calculated MU systematic underestimated by 5.5±2.5% compared to XVMC. With individual correction, mean hand-calculated MUs matched with XVMC by - 0.3±1.4%/0.4±1.4 for beams/arcs, respectively. After average 5% correction, hand-calculated MUs matched with XVMC by 0.5±2.5%/0.6±2.0% for beams/arcs, respectively. Smaller dependence on tumor volume(TV)/field size(FS) was also observed. Ion-chamber measurement was within ±3.0%. Conclusion: PB-hete overestimates dose to lung tumor relative to XVMC. XVMC-algorithm is much more-complex and accurate with tissues-heterogeneities. Measurement at machine is time consuming and need extra resources; also direct measurement of dose for heterogeneous treatment plans is not clinically practiced, yet. This simple correction-based method was very helpful for independent-2nd-check of MC-lung-SBRT plans and routinely used in our clinic. A look-up table can be generated to include TV/FS dependence in ICFs.« less

  5. Use of a Proximity Sensor Switch for "Hands Free" Operation of Computer-Based Video Prompting by Young Adults with Moderate Intellectual Disability

    ERIC Educational Resources Information Center

    Ivey, Alexandria N.; Mechling, Linda C.; Spencer, Galen P.

    2015-01-01

    In this study, the effectiveness of a "hands free" approach for operating video prompts to complete multi-step tasks was measured. Students advanced the video prompts by using a motion (hand wave) over a proximity sensor switch. Three young adult females with a diagnosis of moderate intellectual disability participated in the study.…

  6. Computer implemented method, and apparatus for controlling a hand-held tool

    NASA Technical Reports Server (NTRS)

    Wagner, Kenneth William (Inventor); Taylor, James Clayton (Inventor)

    1999-01-01

    The invention described here in is a computer-implemented method and apparatus for controlling a hand-held tool. In particular, the control of a hand held tool is for the purpose of controlling the speed of a fastener interface mechanism and the torque applied to fasteners by the fastener interface mechanism of the hand-held tool and monitoring the operating parameters of the tool. The control is embodied in intool software embedded on a processor within the tool which also communicates with remote software. An operator can run the tool, or through the interaction of both software, operate the tool from a remote location, analyze data from a performance history recorded by the tool, and select various torque and speed parameters for each fastener.

  7. MO-E-18C-02: Hands-On Monte Carlo Project Assignment as a Method to Teach Radiation Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pater, P; Vallieres, M; Seuntjens, J

    2014-06-15

    Purpose: To present a hands-on project on Monte Carlo methods (MC) recently added to the curriculum and to discuss the students' appreciation. Methods: Since 2012, a 1.5 hour lecture dedicated to MC fundamentals follows the detailed presentation of photon and electron interactions. Students also program all sampling steps (interaction length and type, scattering angle, energy deposit) of a MC photon transport code. A handout structured in a step-by-step fashion guides student in conducting consistency checks. For extra points, students can code a fully working MC simulation, that simulates a dose distribution for 50 keV photons. A kerma approximation to dosemore » deposition is assumed. A survey was conducted to which 10 out of the 14 attending students responded. It compared MC knowledge prior to and after the project, questioned the usefulness of radiation physics teaching through MC and surveyed possible project improvements. Results: According to the survey, 76% of students had no or a basic knowledge of MC methods before the class and 65% estimate to have a good to very good understanding of MC methods after attending the class. 80% of students feel that the MC project helped them significantly to understand simulations of dose distributions. On average, students dedicated 12.5 hours to the project and appreciated the balance between hand-holding and questions/implications. Conclusion: A lecture on MC methods with a hands-on MC programming project requiring about 14 hours was added to the graduate study curriculum since 2012. MC methods produce “gold standard” dose distributions and slowly enter routine clinical work and a fundamental understanding of MC methods should be a requirement for future students. Overall, the lecture and project helped students relate crosssections to dose depositions and presented numerical sampling methods behind the simulation of these dose distributions. Research funding from governments of Canada and Quebec. PP acknowledges partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council (Grant number: 432290)« less

  8. A novel radiation protection drape reduces radiation exposure during fluoroscopy guided electrophysiology procedures.

    PubMed

    Germano, Joseph J; Day, Gina; Gregorious, David; Natarajan, Venkataraman; Cohen, Todd

    2005-09-01

    The purpose of this study was to evaluate a novel disposable lead-free radiation protection drape for decreasing radiation scatter during electrophysiology procedures. In recent years, there has been an exponential increase in the number of electrophysiology (EP) procedures exposing patients, operators and laboratory staff to higher radiation doses. The RADPAD was positioned slightly lateral to the incision site for pectoral device implants and superior to the femoral vein during electrophysiology studies. Each patient served as their own control and dosimetric measurements were obtained at the examiner's elbow and hand. Radiation badge readings for the operator were obtained three months prior to RADPAD use and three months after introduction. Radiation dosimetry was obtained in twenty patients: 7 electrophysiology studies, 6 pacemakers, 5 catheter ablations, and 2 implantable cardioverter-defibrillators. Eleven women and nine men with a mean age of 63 +/- 4 years had an average fluoroscopy time of 2.5 +/- 0.42 minutes per case. Mean dosimetric measurements at the hand were reduced from 141.38 +/- 24.67 to 48.63 +/- 9.02 milliroentgen (mR) per hour using the protective drape (63% reduction; p < 0.0001). Measurements at the elbow were reduced from 78.78 +/- 7.95 mR per hour to 34.50 +/- 4.18 mR per hour using the drape (55% reduction; p < 0.0001). Badge readings for three months prior to drape introduction averaged 2.45 mR per procedure versus 1.54 mR per procedure for 3 months post-initiation (37% reduction). The use of a novel radiation protection surgical drape can significantly reduce scatter radiation exposure to staff and operators during a variety of EP procedures.

  9. Kinesthetic coupling between operator and remote manipulator

    NASA Technical Reports Server (NTRS)

    Bejczy, A. K.; Salisbury, J. K., Jr.

    1980-01-01

    A universal force-reflecting hand controller has been developed which allows the establishment of a kinesthetic coupling between the operator and a remote manipulator. The six-degree-of-freedom controller was designed to generate forces and torques on its three positional and three rotational axes in order to permit the operator to accurately feel the forces encountered by the manipulator and be as transparent to operate as possible. The universal controller has been used in an application involving a six-degree-of-freedom mechanical arm equipped with a six-dimensional force-torque sensor at its base. In this application, the hand controller acts as a position control input device to the arm, while forces and torques sensed at the base of the mechanical hand back drive the hand controller. The positional control relation and the back driving of the controller according to inputs experienced by the force-torque sensor are established through complex mathematical transformations performed by a minicomputer. The hand controller is intended as a development tool for investigating force-reflecting master-slave manipulator control technology.

  10. Comparative Study of Hand-Sutured versus Circular Stapled Anastomosis for Gastrojejunostomy in Laparoscopy Assisted Distal Gastrectomy.

    PubMed

    Seo, Su Hyun; Kim, Ki Han; Kim, Min Chan; Choi, Hong Jo; Jung, Ghap Joong

    2012-06-01

    Mechanical stapler is regarded as a good alternative to the hand sewing technique, when used in gastric reconstruction. The circular stapling method has been widely applied to gastrectomy (open orlaparoscopic), for gastric cancer. We illustrated and compared the hand-sutured method to the circular stapling method, for Billroth-II, in patients who underwent laparoscopy assisted distal gastrectomy for gastric cancer. Between April 2009 and May 2011, 60 patients who underwent laparoscopy assisted distal gastrectomy, with Billroth-II, were enrolled. Hand-sutured Billroth-II was performed in 40 patients (manual group) and circular stapler Billroth-II was performed in 20 patients (stapler group). Clinicopathological features and post-operative outcomes were evaluated and compared between the two groups. Nosignificant differences were observed in clinicopathologic parameters and post-operative outcomes, except in the operation times. Operation times and anastomosis times were significantly shorter in the stapler group (P=0.004 and P<0.001). Compared to the hand-sutured method, the circular stapling method can be applied safely and more efficiently, when performing Billroth-II anastomosis, after laparoscopy assisted distal gastrectomy in patients with gastric cancer.

  11. Hand-handle interface force and torque measurement system for pneumatic assembly tool operations: suggested enhancement to ISO 6544.

    PubMed

    Lin, Jia-Hua; McGorry, Raymond W; Chang, Chien-Chi

    2007-05-01

    A hand-handle interface force and torque measurement system is introduced to fill the void acknowledged in the international standard ISO 6544, which governs pneumatic, assembly tool reaction torque and force measurement. This system consists of an instrumented handle with a sensor capable of measuring grip force and reaction hand moment when threaded, fastener-driving tools are used by operators. The handle is rigidly affixed to the tool in parallel to the original tool handle allowing normal fastener-driving operations with minimal interference. Demonstration of this proposed system was made with tools of three different shapes: pistol grip, right angle, and in-line. During tool torque buildup, the proposed system measured operators exerting greater grip force on the soft joint than on the hard joint. The system also demonstrated that the soft joint demanded greater hand moment impulse than the hard joint. The results demonstrate that the measurement system can provide supplemental data useful in exposure assessment with power hand tools as proposed in ISO 6544.

  12. Kinematics of the six-degree-of-freedom force-reflecting Kraft Master

    NASA Technical Reports Server (NTRS)

    Williams, Robert L., II

    1991-01-01

    Presented here are kinematic equations for a six degree of freedom force-reflecting hand controller. The forward kinematics solution is developed and shown in simplified form. The Jacobian matrix, which uses terms from the forward kinematics solution, is derived. Both of these kinematic solutions require joint angle inputs. A calibration method is presented to determine the hand controller joint angles given the respective potentiometer readings. The kinematic relationship describing the mechanical coupling between the hand and controller shoulder and elbow joints is given. These kinematic equations may be used in an algorithm to control the hand controller as a telerobotic system component. The purpose of the hand controller is two-fold: operator commands to the telerobotic system are entered using the hand controller, and contact forces and moments from the task are reflected to the operator via the hand controller.

  13. Syringe size: does it matter in physician-performed procedures?

    PubMed

    Michael, Adrian A; Moorjani, Gautam R; Peisajovich, Andres; Park, Kye S; Sibbitt, Wilmer L; Bankhurst, Arthur D

    2009-03-01

    We hypothesized that the size of syringe influenced needle control in physician-performed procedures. Operators were tested for their ability to control a 1-, 3-, 5-, 10-, and 20-mL syringe and equivalent sizes of the new safety device, the reciprocating procedure device (RPD), using the quantitative needle-based displacement method. Three hundred twenty clinical syringe procedures were then randomized to either a 3- or 10-mL conventional syringe or to a 3- or 10-mL RPD. Patient pain was measured with the Visual Analog Pain Scale (VAPS). Increasing syringe size was associated with the undesirable characteristic of unintended forward penetration (loss of control of the needle in the forward direction) (r(2) = 0.97, slope = 2.14, 95% CI: 1.54-2.76, P < 0.002), and unintended retraction (loss of control of the needle in the reverse direction) (r(2) = 0.97, slope 2.15, 95% CI: 1.54-2.76, P < 0.002). In addition, 2-handed operation of a syringe resulted in greater control than 1-handed operation of a syringe (P < 0.001). When 1-handed operation was required, the RPD control syringe reduced unintended penetration by 52.3% (P >or= 0.001), unintended retraction by 56.8% (P >or= 0.001), and patient pain by 54.7% (P >or= 0.001) at each device size. For greater safety and control when operating the conventional syringe, smaller syringe sizes and 2 hands instead of 1 hand should be used whenever possible. If 1-handed operation of a syringe is necessary, a safety technology like the RPD control syringe should be used.

  14. Quantifying technical skills during open operations using video-based motion analysis.

    PubMed

    Glarner, Carly E; Hu, Yue-Yung; Chen, Chia-Hsiung; Radwin, Robert G; Zhao, Qianqian; Craven, Mark W; Wiegmann, Douglas A; Pugh, Carla M; Carty, Matthew J; Greenberg, Caprice C

    2014-09-01

    Objective quantification of technical operative skills in surgery remains poorly defined, although the delivery of and training in these skills is essential to the profession of surgery. Attempts to measure hand kinematics to quantify operative performance primarily have relied on electromagnetic sensors attached to the surgeon's hand or instrument. We sought to determine whether a similar motion analysis could be performed with a marker-less, video-based review, allowing for a scalable approach to performance evaluation. We recorded six reduction mammoplasty operations-a plastic surgery procedure in which the attending and resident surgeons operate in parallel. Segments representative of surgical tasks were identified with Multimedia Video Task Analysis software. Video digital processing was used to extract and analyze the spatiotemporal characteristics of hand movement. Attending plastic surgeons appear to use their nondominant hand more than residents when cutting with the scalpel, suggesting more use of countertraction. While suturing, attendings were more ambidextrous, with smaller differences in movement between their dominant and nondominant hands than residents. Attendings also seem to have more conservation of movement when performing instrument tying than residents, as demonstrated by less nondominant hand displacement. These observations were consistent within procedures and between the different attending plastic surgeons evaluated in this fashion. Video motion analysis can be used to provide objective measurement of technical skills without the need for sensors or markers. Such data could be valuable in better understanding the acquisition and degradation of operative skills, providing enhanced feedback to shorten the learning curve. Copyright © 2014 Mosby, Inc. All rights reserved.

  15. From Auto- to Allotransplantation: Immunomodulatory Protocol for Hand and Arm Transplantation.

    PubMed

    Lee, W P Andrew; Shores, Jaimie T; Brandacher, Gerald

    2018-05-18

     To achieve a favorable risk-benefit balance for hand transplantation, an immunomodulatory protocol was developed in the laboratory and translated to clinical application.  Following donor bone marrow infusion into transplant recipients, hand and arm allografts have been maintained on low-dose tacrolimus monotherapy.  Good-to-excellent functional recovery has been achieved in patients compliant with medication and therapy, thus restoring autonomous and productive lives.  The risk-benefit balance can be tilted in favor of the hand transplant recipients by using an immunomodulatory protocol with minimum immunosuppression. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. In vivo measurement of bone aluminum in population living in southern Ontario, Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, K.; Aslam,; Pejovic-Milic, A.

    The harmful biological effect of excessive aluminum (Al) load in humans has been well documented in the literature. Al stored in bone, for instance due to dialysis treatment or occupational exposure, can interfere with normal bone remodeling leading to osteodystrophy, osteoarthritis, or osteomalacia. On the other hand, the relationship between chronic Al exposure and the risk of Alzheimer's disease remains controversial. In this work, the feasibility of in vivo neutron activation analysis (IVNAA) for measuring Al levels in the human hand bone, using the thermal neutron capture reaction {sup 27}Al(n,{gamma}){sup 28}Al, is reported. This noninvasive diagnostic technique employs a highmore » beam current Tandetron accelerator based neutron source, an irradiation/shielding cavity, a 4{pi} NaI(Tl) detector system, and a new set of hand bone phantoms. The photon spectra of the irradiated phantom closely resemble those collected from the hands of nonexposed healthy subjects. A protocol was developed using the newly developed hand phantoms, which resulted in a minimum detectable limit (MDL) of 0.29 mg Al in the human hand. Using the ratio of Al to Ca as an index of Al levels per unit bone mass, the MDL was determined as 19.5{+-}1.5 {mu}g Al/g Ca, which is within the range of the measured levels of 20-27 {mu}g Al/g Ca[ICRP, Report of the Task Group on Reference Man, Publication 23 (Pergamon, Oxford, 1975)] found in other in vivo and in vitro studies. Following the feasibility studies conducted with phantoms, the diagnostic technique was used to measure Al levels in the hand bones of 20 healthy human subjects. The mean hand bone Al concentration was determined as 27.1{+-}16.1 ({+-}1 SD) {mu}g Al/g Ca. The average standard error (1{sigma}) in the Al/Ca is 14.0 {mu}g Al/g Ca, which corresponds to an average relative error of 50% in the measured levels of Al/Ca. These results were achieved with a dose equivalent of 17.6 mSv to a hand and an effective dose of 14.4 {mu}Sv. This effective dose is approximately half of that received in a chest radiograph examination. It is recommended to investigate the use of the bone Al IVNAA diagnostic technique for in vivo measurements of patients with documented overload of Al in bone.« less

  17. Iterative co-creation for improved hand hygiene and aseptic techniques in the operating room: experiences from the safe hands study.

    PubMed

    Erichsen Andersson, Annette; Frödin, Maria; Dellenborg, Lisen; Wallin, Lars; Hök, Jesper; Gillespie, Brigid M; Wikström, Ewa

    2018-01-04

    Hand hygiene and aseptic techniques are essential preventives in combating hospital-acquired infections. However, implementation of these strategies in the operating room remains suboptimal. There is a paucity of intervention studies providing detailed information on effective methods for change. This study aimed to evaluate the process of implementing a theory-driven knowledge translation program for improved use of hand hygiene and aseptic techniques in the operating room. The study was set in an operating department of a university hospital. The intervention was underpinned by theories on organizational learning, culture and person centeredness. Qualitative process data were collected via participant observations and analyzed using a thematic approach. Doubts that hand-hygiene practices are effective in preventing hospital acquired infections, strong boundaries and distrust between professional groups and a lack of psychological safety were identified as barriers towards change. Facilitated interprofessional dialogue and learning in "safe spaces" worked as mechanisms for motivation and engagement. Allowing for the free expression of different opinions, doubts and viewing resistance as a natural part of any change was effective in engaging all professional categories in co-creation of clinical relevant solutions to improve hand hygiene. Enabling nurses and physicians to think and talk differently about hospital acquired infections and hand hygiene requires a shift from the concept of one-way directed compliance towards change and learning as the result of a participatory and meaning-making process. The present study is a part of the Safe Hands project, and is registered with ClinicalTrials.gov (ID: NCT02983136 ). Date of registration 2016/11/28, retrospectively registered.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boehling, Nicholas S.; Grosshans, David R., E-mail: dgrossha@mdanderson.org; Bluett, Jaques B.

    Purpose: Cranial irradiation in pediatric patients is associated with serious long-term adverse effects. We sought to determine whether both three-dimensional conformal proton radiotherapy (3D-PRT) and intensity-modulated proton therapy (IMPT) compared with intensity-modulated radiotherapy (IMRT) decrease integral dose to brain areas known to harbor neuronal stem cells, major blood vessels, and other normal brain structures for pediatric patients with craniopharyngiomas. Methods and Materials: IMRT, forward planned, passive scattering proton, and IMPT plans were generated and optimized for 10 pediatric patients. The dose was 50.4 Gy (or cobalt Gy equivalent) delivered in 28 fractions with the requirement for planning target volume (PTV)more » coverage of 95% or better. Integral dose data were calculated from differential dose-volume histograms. Results: The PTV target coverage was adequate for all modalities. IMRT and IMPT yielded the most conformal plans in comparison to 3D-PRT. Compared with IMRT, 3D-PRT and IMPT plans had a relative reduction of integral dose to the hippocampus (3D-PRT, 20.4; IMPT, 51.3%{sup Asterisk-Operator }), dentate gyrus (27.3, 75.0%{sup Asterisk-Operator }), and subventricular zone (4.5, 57.8%{sup Asterisk-Operator }). Vascular organs at risk also had reduced integral dose with the use of proton therapy (anterior cerebral arteries, 33.3{sup Asterisk-Operator }, 100.0%{sup Asterisk-Operator }; middle cerebral arteries, 25.9%{sup Asterisk-Operator }, 100%{sup Asterisk-Operator }; anterior communicating arteries, 30.8{sup Asterisk-Operator }, 41.7%{sup Asterisk-Operator }; and carotid arteries, 51.5{sup Asterisk-Operator }, 77.6{sup Asterisk-Operator }). Relative reduction of integral dose to the infratentorial brain (190.7{sup Asterisk-Operator }, 109.7%{sup Asterisk-Operator }), supratentorial brain without PTV (9.6, 26.8%{sup Asterisk-Operator }), brainstem (45.6, 22.4%{sup Asterisk-Operator }), and whole brain without PTV (19.4{sup Asterisk-Operator }, 34.4%{sup Asterisk-Operator }) were recorded with the use of proton therapy. ({sup Asterisk-Operator }Differences were significant based on Friedman's test with Bonferroni-Dunn correction, {alpha} = 0.05) Conclusions: The current study found that proton therapy was able to avoid excess integral radiation dose to a variety of normal structures at all dose levels while maintaining equal target coverage. Future studies will examine the clinical benefits of these dosimetric advantages.« less

  19. 49 CFR 229.87 - Hand-operated switches.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Hand-operated switches. 229.87 Section 229.87 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Electrical System § 229...

  20. A Comparison of Image Quality and Radiation Exposure Between the Mini C-Arm and the Standard C-Arm.

    PubMed

    van Rappard, Juliaan R M; Hummel, Willy A; de Jong, Tijmen; Mouës, Chantal M

    2018-04-01

    The use of intraoperative fluoroscopy has become mandatory in osseous hand surgery. Due to its overall practicality, the mini C-arm has gained popularity among hand surgeons over the standard C-arm. This study compares image quality and radiation exposure for patient and staff between the mini C-arm and the standard C-arm, both with flat panel technology. An observer-based subjective image quality study was performed using a contrast detail (CD) phantom. Five independent observers were asked to determine the smallest circles discernable to them. The results were plotted in a graph, forming a CD curve. From each curve, an image quality figure (IQF) was derived. A lower IQF equates to a better image quality. The patients' entrance skin dose was measured, and to obtain more information about the staff exposure dose, a perspex hand phantom was used. The scatter radiation was measured at various distances and angles relative to a central point on the detector. The IQF was significantly lower for the mini C-arm resulting in a better image quality. The patients' entrance dose was 10 times higher for the mini C-arm as compared with the standard C-arm, and the scatter radiation threefold. Due to its improved image quality and overall practicality, the mini C-arm is recommended for hand surgical procedures. To ensure that the surgeons' radiation exposure is not exceeding the safety limits, monitoring radiation exposure using mini C-arms with flat panel technology during surgery should be done in a future clinical study.

  1. [Passive smoking--health consequences and effects of exposure prevention].

    PubMed

    Raupach, T; Radon, K; Nowak, D; Andreas, S

    2008-01-01

    Passive smoking is the third leading but preventable cause of death worldwide. It is associated with an elevated risk of developing acute respiratory diseases, obstructive lung disorders, lung cancer, and cardiovascular disease. Whereas the dose-response relationship between second-hand smoke exposure and respiratory diseases is likely to be linear, a non-linear dose-response curve has been observed with respect to acute cardiovascular events. This explains the disproportionately high risk of myocardial infarction among passive smokers as compared to unexposed individuals. Over the last ten years, exposure to second-hand smoke has declined in Germany, but it is still substantial. With passive smoking in the home being a difficult target for preventive measures, public smoking bans have recently been shown to greatly reduce second-hand smoke-related morbidity and mortality. In addition, such measures are usually well tolerated and highly relevant regarding legal aspects related to workplace issues. This article summarises the current evidence on the health consequences of passive smoking and on the favourable effects of public smoking bans.

  2. Myoelectric control of prosthetic hands: state-of-the-art review

    PubMed Central

    Geethanjali, Purushothaman

    2016-01-01

    Myoelectric signals (MES) have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. PMID:27555799

  3. Web-based healthcare hand drawing management system.

    PubMed

    Hsieh, Sheau-Ling; Weng, Yung-Ching; Chen, Chi-Huang; Hsu, Kai-Ping; Lin, Jeng-Wei; Lai, Feipei

    2010-01-01

    The paper addresses Medical Hand Drawing Management System architecture and implementation. In the system, we developed four modules: hand drawing management module; patient medical records query module; hand drawing editing and upload module; hand drawing query module. The system adapts windows-based applications and encompasses web pages by ASP.NET hosting mechanism under web services platforms. The hand drawings implemented as files are stored in a FTP server. The file names with associated data, e.g. patient identification, drawing physician, access rights, etc. are reposited in a database. The modules can be conveniently embedded, integrated into any system. Therefore, the system possesses the hand drawing features to support daily medical operations, effectively improve healthcare qualities as well. Moreover, the system includes the printing capability to achieve a complete, computerized medical document process. In summary, the system allows web-based applications to facilitate the graphic processes for healthcare operations.

  4. Ionizing radiation sensitivity of the ocular lens and its dose rate dependence.

    PubMed

    Hamada, Nobuyuki

    2017-10-01

    In 2011, the International Commission on Radiological Protection reduced the threshold for the lens effects of low linear energy transfer (LET) radiation. On one hand, the revised threshold of 0.5 Gy is much lower than previously recommended thresholds, but mechanisms behind high radiosensitivity remain incompletely understood. On the other hand, such a threshold is independent of dose rate, in contrast to previously recommended separate thresholds each for single and fractionated/protracted exposures. Such a change was made predicated on epidemiological evidence suggesting that a threshold for fractionated/protracted exposures is not higher than an acute threshold, and that a chronic threshold is uncertain. Thus, the dose rate dependence is still unclear. This paper therefore reviews the current knowledge on the radiosensitivity of the lens and the dose rate dependence of radiation cataractogenesis, and discusses its mechanisms. Mounting biological evidence indicates that the lens cells are not necessarily radiosensitive to cell killing, and the high radiosensitivity of the lens thus appears to be attributable to other mechanisms (e.g., excessive proliferation, abnormal differentiation, a slow repair of DNA double-strand breaks, telomere, senescence, crystallin changes, non-targeted effects and inflammation). Both biological and epidemiological evidence generally supports the lack of dose rate effects. However, there is also biological evidence for the tissue sparing dose rate (or fractionation) effect of low-LET radiation and an enhancing inverse dose fractionation effect of high-LET radiation at a limited range of LET. Emerging epidemiological evidence in chronically exposed individuals implies the inverse dose rate effect. Further biological and epidemiological studies are warranted to gain deeper knowledge on the radiosensitivity of the lens and dose rate dependence of radiation cataractogenesis.

  5. Impact of the use of an alcohol-based hand sanitizer in the home on reduction in probability of infection by respiratory and enteric viruses.

    PubMed

    Tamimi, A H; Maxwell, S; Edmonds, S L; Gerba, C P

    2015-11-01

    The goal of this study was to determine the reduction in risk of infection by viruses with the use of an alcohol-based hand sanitizer, used in addition to routine hand washing, in family members in households. A quantitative microbial risk model was used to determine the probability of infection from the concentration of virus on the hands. The model incorporated variation in hand size, frequency of touching orifices (nose, mouth, eyes), and percent transfer to the site of infection, as well as, dose-response for each virus. Data on the occurrence of virus on household members' hands from an intervention study using MS-2 coliphage was used to determine the reduction of viruses on the hands pre- and post-intervention. It was found that the risk of rhinovirus, rotavirus or norovirus infection after the intervention was reduced by 47-98% depending upon the initial concentration of virus on the hands.

  6. Kinematic rate control of simulated robot hand at or near wrist singularity

    NASA Technical Reports Server (NTRS)

    Barker, K.; Houck, J. A.; Carzoo, S. W.

    1985-01-01

    A robot hand should obey movement commands from an operator on a computer program as closely as possible. However, when two of the three rotational axes of the robot wrist are colinear, the wrist loses a degree of freedom, and the usual resolved rate equations (used to move the hand in response to an operator's inputs) are indeterminant. Furthermore, rate limiting occurs in close vicinity to this singularity. An analysis shows that rate limiting occurs not only in the vicinity of this singularity but also substantially away from it, even when the operator commands rotational rates of the robot hand that are only a small percentage of the operational joint rate limits. Therefore, joint angle rates are scaled when they exceed operational limits in a real time simulation of a robot arm. Simulation results show that a small dead band avoids the wrist singularity in the resolved rate equations but can introduce a high frequency oscillation close to the singularity. However, when a coordinated wrist movement is used in conjunction with the resolved rate equations, the high frequency oscillation disappears.

  7. STS-33 MS Carter operates translation hand control (THC) on aft flight deck

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-33 Mission Specialist (MS) Manley L. Carter, Jr operates translation hand control (THC) at the aft flight deck onorbit station while peering out overhead window W7. Carter's communications kit assembly headset microphone extends across his face.

  8. Knee-laxity measurements examined by a left-hand- and a right-hand-dominant physiotherapist, in patients with anterior cruciate ligament injuries and healthy controls.

    PubMed

    Sernert, Ninni; Helmers, Janett; Kartus, Catarina; Ejerhed, Lars; Kartus, Jüri

    2007-10-01

    The purpose of the study was to analyse and compare KT-1000 knee laxity as examined by a left-hand- and a right-hand-dominant physiotherapist in a group of patients with an anterior cruciate ligament (ACL) injury and a group of patients, 2 years after ACL reconstruction. The other aim was to measure and analyse knee laxity in a group of persons without any known knee problems. A cross-sectional examination of two groups of patients pre-operatively and post-operatively after ACL reconstruction and examination of healthy controls on two different occasions was performed. Fifty-three patients who were scheduled for ACL reconstruction and 39 patients who attended a 2-year follow-up examination were included in the study. In the ACL-deficient group, 32 patients had a right-sided ACL injury and 21 patients a left-sided ACL injury. The corresponding figures in the post-operative group were 21 patients with a right-sided ACL injury and 18 patients with a left-sided ACL injury. Twenty-eight healthy persons without any known knee problems served as controls. One left-hand- and one right-hand-dominant experienced physiotherapist performed all the examinations. To be able to evaluate the intra and inter-reliability of the examiners the controls were examined at two occasions. The left-hand-dominant physiotherapist measured significantly higher absolute laxity values in the left knee, both injured and non-injured ones, compared with the right-hand-dominant physiotherapist. This was found irrespectively of whether the patients belonged to the ACL deficient or the post-operative group. In the healthy control group, the right-hand-dominant physiotherapist measured significantly higher knee-laxity values in the right knee compared with the left-hand-dominant physiotherapist. Correspondingly, the left-hand-dominant physiotherapist measured significantly higher knee laxity values in the left knee. We conclude that KT-1000 arthrometer laxity measurements can be affected by the hand dominance of the examiner. This might affect the reliability of KT-1000 arthrometer measurements. Level of evidence is II.

  9. Design of the NASA Robonaut Hand

    NASA Technical Reports Server (NTRS)

    Lovchik, Chris S.; Aldridge, H. A.; Driftler, Myron A.

    1999-01-01

    The design of a highly anthropomorphic human scale robot hand for space based operations is described. This five finger hand combined with its integrated wrist and forearm has fourteen independent degrees of freedom. The device approximates very well the kinematics and required strength of an astronaut's hand when operating through a pressurized space suit glove. The mechanisms used to meet these requirements are explained in detail along with the design philosophy behind them. Integration experiences reveal the challenges associated with obtaining the required capabilities within the desired size. The initial finger control strategy is presented along with examples of obtainable grasps.

  10. Space Shuttle Reusable Solid Rocket Motor (RSRM) Hand Cleaning Solvent Replacement at Kennedy Space Center (KSC)

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; DeWeese, Darrell C.; Key, Leigh W.

    1997-01-01

    At Kennedy Space Center (KSC), Thiokol Corporation provides the engineering to assemble and prepare the Space Shuttle Reusable Solid Rocket Motor (RSRM) for launch. This requires hand cleaning over 86 surfaces including metals, adhesives, rubber and electrical insulations, various painted surfaces and thermal protective materials. Due to the phase-out of certain ozone depleting chemical (ODC) solvents, all RSRM hand wipe operations being performed at KSC using l,l,1-trichloroethane (TCA) were eliminated. This presentation summarizes the approach used and the data gathered in the effort to eliminate TCA from KSC hand wipe operations.

  11. Comparative Study of Hand-Sutured versus Circular Stapled Anastomosis for Gastrojejunostomy in Laparoscopy Assisted Distal Gastrectomy

    PubMed Central

    Seo, Su Hyun; Kim, Min Chan; Choi, Hong Jo; Jung, Ghap Joong

    2012-01-01

    Purpose Mechanical stapler is regarded as a good alternative to the hand sewing technique, when used in gastric reconstruction. The circular stapling method has been widely applied to gastrectomy (open orlaparoscopic), for gastric cancer. We illustrated and compared the hand-sutured method to the circular stapling method, for Billroth-II, in patients who underwent laparoscopy assisted distal gastrectomy for gastric cancer. Materials and Methods Between April 2009 and May 2011, 60 patients who underwent laparoscopy assisted distal gastrectomy, with Billroth-II, were enrolled. Hand-sutured Billroth-II was performed in 40 patients (manual group) and circular stapler Billroth-II was performed in 20 patients (stapler group). Clinicopathological features and post-operative outcomes were evaluated and compared between the two groups. Results Nosignificant differences were observed in clinicopathologic parameters and post-operative outcomes, except in the operation times. Operation times and anastomosis times were significantly shorter in the stapler group (P=0.004 and P<0.001). Conclusions Compared to the hand-sutured method, the circular stapling method can be applied safely and more efficiently, when performing Billroth-II anastomosis, after laparoscopy assisted distal gastrectomy in patients with gastric cancer. PMID:22792525

  12. Hand-held computer operating system program for collection of resident experience data.

    PubMed

    Malan, T K; Haffner, W H; Armstrong, A Y; Satin, A J

    2000-11-01

    To describe a system for recording resident experience involving hand-held computers with the Palm Operating System (3 Com, Inc., Santa Clara, CA). Hand-held personal computers (PCs) are popular, easy to use, inexpensive, portable, and can share data among other operating systems. Residents in our program carry individual hand-held database computers to record Residency Review Committee (RRC) reportable patient encounters. Each resident's data is transferred to a single central relational database compatible with Microsoft Access (Microsoft Corporation, Redmond, WA). Patient data entry and subsequent transfer to a central database is accomplished with commercially available software that requires minimal computer expertise to implement and maintain. The central database can then be used for statistical analysis or to create required RRC resident experience reports. As a result, the data collection and transfer process takes less time for residents and program director alike, than paper-based or central computer-based systems. The system of collecting resident encounter data using hand-held computers with the Palm Operating System is easy to use, relatively inexpensive, accurate, and secure. The user-friendly system provides prompt, complete, and accurate data, enhancing the education of residents while facilitating the job of the program director.

  13. Assessment of human exposure doses received by activation of medical linear accelerator components

    NASA Astrophysics Data System (ADS)

    Lee, D.-Y.; Kim, J.-H.; Park, E.-T.

    2017-08-01

    This study analyzes the radiation exposure dose that an operator can receive from radioactive components during maintenance or repair of a linear accelerator. This study further aims to evaluate radiological safety. Simulations are performed on 10 MV and 15 MV photon beams, which are the most frequently used high-energy beams in clinics. The simulation analyzes components in order of activity and the human exposure dose based on the amount of neutrons received. As a result, the neutron dose, radiation dose, and human exposure dose are ranked in order of target, primary collimator, flattening filter, multi-leaf collimator, and secondary collimator, where the minimum dose is 9.34E-07 mSv/h and the maximum is 1.71E-02 mSv/h. When applying the general dose limit (radiation worker 20 mSv/year, pubic 1 mSv/year) in accordance with the Nuclear Safety Act, all components of a linear accelerator are evaluated as below the threshold value. Therefore, the results suggest that there is no serious safety issue for operators in maintaining and repairing a linear accelerator. Nevertheless, if an operator recognizes an exposure from the components of a linear accelerator during operation and considers the operating time and shielding against external exposure, exposure of the operator is expected to be minimized.

  14. Demodicosis in red-handed tamarins (Saguinus midas).

    PubMed

    James, S B; Raphael, B L

    2000-06-01

    Two nonrelated but paired red-handed tamarins (Saguinus midas) presented with diffuse, multifocal, raised, nonpruritic, hyperkeratotic lesions on the appendages and face. Skin biopsies identified acarids and skin scrapings confirmed demodex-like mites. The animals were treated with ivermectin, at the endoparasite dose, which initially resulted in resolution of clinical signs; however, signs recurred after numerous treatments. After four treatments with amitraz dips, demodicosis lesions resolved.

  15. Radiation therapy in adenoid-cystic carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vikram, B.; Strong, E.W.; Shah, J.P.

    1984-02-01

    Between 1949-1977, 74 patients with adenoid-cystic carcinoma of various head and neck sites were treated by radiation therapy at Memorial Sloan-Kettering Cancer Center. Radiation therapy alone was employed in 49 patients for recurrent, unresectable disease, and in 25 patients it was given as an adjunct to surgical resection. Among the 49 patients treated with radiation therapy alone, tumor regression was seen in 47 (96%). However, 44 of the 47 (93.5%) subsequently relapsed locally. Relapse occurred within 18 months in one-half of the patients and within 5 years in all of them. Of the 25 patients who received adjunctive radiation therapymore » about one-half relapsed locally within five years. There were 9 patients in this group, however, whose field size exceeded 8x8 cm and the dose of radiation also exceeded 4500 rad: 88% of these patients remained relapse-free at 5 years, compared with only 22% of the other 16 whose dose, or field size, or both, were inadequate by comparison. These data suggest that when irradiation is employed for advanced, inoperable adenoid-cystic carcinoma, it offers useful palliation but is rarely, if ever, curative. Postoperative irradiation, on the other hand, might improve the local control and the survival in patients with operable adenoid-cystic carcinoma who are at high risk for relapse, but only if the field size and the dose are adequate.« less

  16. Controversy of hand-assisted laparoscopic colorectal surgery

    PubMed Central

    Meshikhes, Abdul-Wahed Nasir

    2010-01-01

    Laparoscopically assisted colorectal procedures are time-consuming and technically demanding and hence have a long steep learning curve. In the technical demand, surgeons need to handle a long mobile organ, the colon, and have to operate on multiple abdominal quadrants, most of the time with the need to secure multiple mesenteric vessels. Therefore, a new surgical innovation called hand-assisted laparoscopic surgery (HALS) was introduced in the mid 1990s as a useful alternative to totally laparoscopic procedures. This hybrid operation allows the surgeon to introduce the non-dominant hand into the abdominal cavity through a special hand port while maintaining the pneumoperitoneum. A hand in the abdomen can restore the tactile sensation which is usually lacking in laparoscopic procedures. It also improves the eye-to-hand coordination, allows the hand to be used for blunt dissection or retraction and also permits rapid control of unexpected bleeding. All of those factors can contribute tremendously to reducing the operative time. Moreover, this procedure is also considered as a hybrid procedure that combines the advantages of both minimally invasive and conventional open surgery. Nevertheless, the exact role of HALS in colorectal surgery has not been well defined during the advanced totally laparoscopic procedures. This article reviews the current status of hand-assisted laparoscopic colorectal surgery as a minimally invasive procedure in the era of laparoscopic surgery. PMID:21128315

  17. Hand controller commonality evaluation process

    NASA Technical Reports Server (NTRS)

    Stuart, Mark A.; Bierschwale, John M.; Wilmington, Robert P.; Adam, Susan C.; Diaz, Manuel F.; Jensen, Dean G.

    1993-01-01

    Hand controller selection for NASA's Orbiter and Space Station Freedom is an important area of human-telerobot interface design and evaluation. These input devices will control remotely operated systems that include large crane-like manipulators (e.g., Remote Manipulator System or RMS), smaller, more dexterous manipulators (e.g., Flight Telerobotic Servicer or FTS), and free flyers (e.g., Orbital Maneuvering Vehicle or OMV). Candidate hand controller configurations for these systems vary in many ways: shape, size, number of degrees-of-freedom (DOF), operating modes, provision of force reflection, range of movement, and 'naturalness' of use. Unresolved design implementation issues remain, including such topics as how the current Orbiter RMS rotational and translational rate hand controllers compare with the proposed Space Station Freedom hand controllers, the advantages that position hand controllers offer for these applications, and whether separate hand controller configurations are required for each application. Since previous studies contain little empirical hand controller task performance data, a controlled study is needed that tests Space Station Freedom candidate hand controllers during representative tasks. This study also needs to include anthropometric and biomechanical considerations.

  18. SU-F-T-67: Correction Factors for Monitor Unit Verification of Clinical Electron Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haywood, J

    Purpose: Monitor units calculated by electron Monte Carlo treatment planning systems are often higher than TG-71 hand calculations for a majority of patients. Here I’ve calculated tables of geometry and heterogeneity correction factors for correcting electron hand calculations. Method: A flat water phantom with spherical volumes having radii ranging from 3 to 15 cm was created. The spheres were centered with respect to the flat water phantom, and all shapes shared a surface at 100 cm SSD. D{sub max} dose at 100 cm SSD was calculated for each cone and energy on the flat phantom and for the spherical volumesmore » in the absence of the flat phantom. The ratio of dose in the sphere to dose in the flat phantom defined the geometrical correction factor. The heterogeneity factors were then calculated from the unrestricted collisional stopping power for tissues encountered in electron beam treatments. These factors were then used in patient second check calculations. Patient curvature was estimated by the largest sphere that aligns to the patient contour, and appropriate tissue density was read from the physical properties provided by the CT. The resulting MU were compared to those calculated by the treatment planning system and TG-71 hand calculations. Results: The geometry and heterogeneity correction factors range from ∼(0.8–1.0) and ∼(0.9–1.01) respectively for the energies and cones presented. Percent differences for TG-71 hand calculations drop from ∼(3–14)% to ∼(0–2)%. Conclusion: Monitor units calculated with the correction factors typically decrease the percent difference to under actionable levels, < 5%. While these correction factors work for a majority of patients, there are some patient anatomies that do not fit the assumptions made. Using these factors in hand calculations is a first step in bringing the verification monitor units into agreement with the treatment planning system MU.« less

  19. Combined Limb-Sparing Surgery and Radiation Therapy to Treat Sarcomas of the Hands and Feet: Long-Term Cancer Outcomes and Morbidity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bishop, Andrew J.; Zagars, Gunar K.; Moon, Bryan S.

    Purpose: The purpose of this study was to investigate local control, survival outcomes, and complication rates of patients treated with limb-sparing surgery and radiation therapy (RT) for soft tissue sarcomas (STS) of the hands and feet. Methods and Materials: We reviewed the medical records of 85 consecutive patients treated for STS of the hands (n=38, 45%) and feet (n=47, 55%) between 1966 and 2012. The median age was 41 years (range, 10-82 years of age). Sixty-seven patients (79%) received postoperative RT after resection of their tumor (median dose, 60 Gy; range, 45-70 Gy). The remaining 18 patients (21%) were treated with preoperative RT followed by tumormore » resection (median dose, 50 Gy; range, 50-64 Gy). Results: Median follow-up was 140 months (range, 24-442 months). Five-year local control, overall survival, and disease-specific survival rates were 86%, 89%, and 89%, respectively. Positive or uncertain surgical margin status was the only factor adversely associated with local recurrence (19% vs 6% for negative margins, P=.046) but this lost significance on multivariate analysis when adjusting for RT dose ≥64 Gy. Of the 12 patients who had local relapses, 6 (50%) were salvaged, and only 2 of those required salvage amputation. Five patients had grade ≥3 late RT sequelae, with 2 patients (2%) having moderate limitations of limb function and 3 patients (4%) having severe limitations requiring procedures for skin ulceration. Conclusions: Limb-sparing surgery combined with RT provides excellent local control outcomes for sarcomas arising in the hands or feet. In patients who have local recurrence, salvage without amputation is possible. The excellent cancer control outcomes observed, considering the minimal impact on limb function, support use of combined modality, limb-sparing local therapy for STS arising in the hands or feet.« less

  20. Combined Limb-Sparing Surgery and Radiation Therapy to Treat Sarcomas of the Hands and Feet: Long-Term Cancer Outcomes and Morbidity.

    PubMed

    Bishop, Andrew J; Zagars, Gunar K; Moon, Bryan S; Lin, Patrick P; Lewis, Valerae O; Guadagnolo, B Ashleigh

    2015-08-01

    The purpose of this study was to investigate local control, survival outcomes, and complication rates of patients treated with limb-sparing surgery and radiation therapy (RT) for soft tissue sarcomas (STS) of the hands and feet. We reviewed the medical records of 85 consecutive patients treated for STS of the hands (n=38, 45%) and feet (n=47, 55%) between 1966 and 2012. The median age was 41 years (range, 10-82 years of age). Sixty-seven patients (79%) received postoperative RT after resection of their tumor (median dose, 60 Gy; range, 45-70 Gy). The remaining 18 patients (21%) were treated with preoperative RT followed by tumor resection (median dose, 50 Gy; range, 50-64 Gy). Median follow-up was 140 months (range, 24-442 months). Five-year local control, overall survival, and disease-specific survival rates were 86%, 89%, and 89%, respectively. Positive or uncertain surgical margin status was the only factor adversely associated with local recurrence (19% vs 6% for negative margins, P=.046) but this lost significance on multivariate analysis when adjusting for RT dose ≥64 Gy. Of the 12 patients who had local relapses, 6 (50%) were salvaged, and only 2 of those required salvage amputation. Five patients had grade ≥3 late RT sequelae, with 2 patients (2%) having moderate limitations of limb function and 3 patients (4%) having severe limitations requiring procedures for skin ulceration. Limb-sparing surgery combined with RT provides excellent local control outcomes for sarcomas arising in the hands or feet. In patients who have local recurrence, salvage without amputation is possible. The excellent cancer control outcomes observed, considering the minimal impact on limb function, support use of combined modality, limb-sparing local therapy for STS arising in the hands or feet. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Mentorship for operational research capacity building: hands-on or hands-off?

    PubMed Central

    Marais, B.; Kool, B.; Ram, S.; Kumar, A. M. V.; Gounder, S.; Viney, K.; Brostrom, R.; Roseveare, C.; Bissell, K.; Reid, A. J.; Zachariah, R.; Hill, P. C.

    2014-01-01

    Mentorship is a key feature of operational research training courses run by the International Union Against Tuberculosis and Lung Disease and Médecins Sans Frontières. During the recent South Pacific paper writing module, the faculty discussed ‘hands-on’ mentorship (direct technical assistance) vs. ‘hands-off’ mentorship (technical advice). This article explores the advantages and disadvantages of each approach. Our collective experience indicates that ‘hands-on’ mentorship is a valuable learning experience for the participant and a rewarding experience for the mentor. This approach increases the likelihood of successful course completion, including publishing a well written paper. However, mentors must allow participants to lead and take ownership of the paper, in keeping with a first author position. PMID:26477290

  2. Mentorship for operational research capacity building: hands-on or hands-off?

    PubMed

    Harries, A D; Marais, B; Kool, B; Ram, S; Kumar, A M V; Gounder, S; Viney, K; Brostrom, R; Roseveare, C; Bissell, K; Reid, A J; Zachariah, R; Hill, P C

    2014-06-21

    Mentorship is a key feature of operational research training courses run by the International Union Against Tuberculosis and Lung Disease and Médecins Sans Frontières. During the recent South Pacific paper writing module, the faculty discussed 'hands-on' mentorship (direct technical assistance) vs. 'hands-off' mentorship (technical advice). This article explores the advantages and disadvantages of each approach. Our collective experience indicates that 'hands-on' mentorship is a valuable learning experience for the participant and a rewarding experience for the mentor. This approach increases the likelihood of successful course completion, including publishing a well written paper. However, mentors must allow participants to lead and take ownership of the paper, in keeping with a first author position.

  3. Cost Savings and Patient Experiences of a Clinic-Based, Wide-Awake Hand Surgery Program at a Military Medical Center: A Critical Analysis of the First 100 Procedures.

    PubMed

    Rhee, Peter C; Fischer, Michelle M; Rhee, Laura S; McMillan, Ha; Johnson, Anthony E

    2017-03-01

    Wide-awake, local anesthesia, no tourniquet (WALANT) hand surgery was developed to improve access to hand surgery care while optimizing medical resources. Hand surgery in the clinic setting may result in substantial cost savings for the United States Military Health Care System (MHS) and provide a safe alternative to performing similar procedures in the operating room. A prospective cohort study was performed on the first 100 consecutive clinic-based WALANT hand surgery procedures performed at a military medical center from January 2014 to September 2015 by a single hand surgeon. Cost savings analysis was performed by using the Medical Expense and Performance Reporting System, the standard cost accounting system for the MHS, to compare procedures performed in the clinic versus the operating room during the study period. A study specific questionnaire was obtained for 66 procedures to evaluate the patient's experience. For carpal tunnel release (n = 34) and A1 pulley release (n = 33), there were 85% and 70% cost savings by having the procedures performed in clinic under WALANT compared with the main operating room, respectively. During the study period, carpal tunnel release, A1 pulley release, and de Quervain release performed in the clinic instead of the operating room amounted to $393,100 in cost savings for the MHS. There were no adverse events during the WALANT procedure. A clinic-based WALANT hand surgery program at a military medical center results in considerable cost savings for the MHS. Economic/Decision Analysis IV. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  4. Automated Hand-Held UXO Detection, Classification & Discrimination Sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bell, Thomas H.

    2000-06-12

    The research focused on procedures for target discrimination and classification using hand-held EMI sensors. The idea is to have a small, portable sensor that can be operated in a sweep or similar pattern in front of the operator, and that is capable of distinguishing between buried UXO and clutter on the spot. Curing Phase 1, we developed the processing techniques for distinguishing between buried UXO and clutter using the EM61-HH hand-held metal detector.

  5. Proposal of a Budget-Friendly Camera Holder for Endoscopic Ear Surgery.

    PubMed

    Ozturan, Orhan; Yenigun, Alper; Aksoy, Fadlullah; Ertas, Burak

    2018-01-01

    Endoscopic ear surgery (EES) is increasingly a preferred technique in otologic society. It offers excellent visualization of the anatomical structures directly and behind the corners with variable angled telescopes. It also provides reduced operative morbidity due to being able to perform surgical interventions with less invasive approaches. Operative preparation and setup time and cost of endoscopy system are less expensive compared with surgical microscopes. On the other hand, the main disadvantage of EES is that the surgery has to be performed with 1 single hand. It is certainly restrictive for an ear surgeon who has been operating with 2 hands under otologic microscopic views for years and certainly requires a learning period and perseverance. Holding the endoscope by a second surgeon is not executable because of insufficient surgical space.Endoscope/camera holders have been developed for those who need the comfort and convenience afforded by double-handed microscopic ear surgery. An ideal endoscope holder should be easy-to-set up, easily controlled, providing a variety of angled views, allowing the surgeon to operate with 2 hands and, budget-friendly. In this article, a commercially available 11-inch magic arm camera holder is proposed by the authors to be used in EES due to its versatile, convenient, and budget-friendly features. It allows 2-handed EES through existing technology and is affordable for surgeons looking for a low-cost and practical solution.

  6. The Hand-Assisted Laparoscopic Approach to Resection of Pancreatic Mucinous Cystic Neoplasms: An Underused Technique?

    PubMed

    Postlewait, Lauren M; Ethun, Cecilia G; McInnis, Mia R; Merchant, Nipun; Parikh, Alexander; Idrees, Kamran; Isom, Chelsea A; Hawkins, William; Fields, Ryan C; Strand, Matthew; Weber, Sharon M; Cho, Clifford S; Salem, Ahmed; Martin, Robert C G; Scoggins, Charles; Bentrem, David; Kim, Hong J; Carr, Jacquelyn; Ahmad, Syed; Abbott, Daniel; Wilson, Gregory C; Kooby, David A; Maithel, Shishir K

    2018-01-01

    Pancreatic mucinous cystic neoplasms (MCNs) are rare tumors typically of the distal pancreas that harbor malignant potential. Although resection is recommended, data are limited on optimal operative approaches to distal pancreatectomy for MCN. MCN resections (2000-2014; eight institutions) were included. Outcomes of minimally invasive and open MCN resections were compared. A total of 289 patients underwent distal pancreatectomy for MCN: 136(47%) minimally invasive and 153(53%) open. Minimally invasive procedures were associated with smaller MCN size (3.9 vs 6.8 cm; P = 0.001), lower operative blood loss (192 vs 392 mL; P = 0.001), and shorter hospital stay(5 vs 7 days; P = 0.001) compared with open. Despite higher American Society of Anesthesiologists class, hand-assisted (n = 46) had similar advantages as laparoscopic/robotic (n = 76). When comparing hand-assisted to open, although MCN size was slightly smaller (4.1 vs 6.8 cm; P = 0.001), specimen length, operative time, and nodal yield were identical. Similar to laparoscopic/robotic, hand-assisted had lower operative blood loss (161 vs 392 mL; P = 0.001) and shorter hospital stay (5 vs 7 days; P = 0.03) compared with open, without increased complications. Hand-assisted laparoscopic technique is a useful approach for MCN resection because specimen length, lymph node yield, operative time, and complication profiles are similar to open procedures, but it still offers the advantages of a minimally invasive approach. Hand-assisted laparoscopy should be considered as an alternative to open technique or as a successive step before converting from total laparoscopic to open distal pancreatectomy for MCN.

  7. Safety of elective hand surgery following axillary lymph node dissection for breast cancer.

    PubMed

    Hershko, Dan D; Stahl, Shalom

    2007-01-01

    The development of lymphedema is the most feared complication shared by breast cancer survivors undergoing hand surgery after prior axillary lymph node dissection (ALND). Traditionally, these patients are advised to avoid any interventional procedures in the ipsilateral upper extremity. However, the appropriateness of some of these precautions was recently challenged by some surgeons claiming that elective hand operations can be safely performed in these patients. The purpose of this study was to evaluate our experience and determine the safety of elective hand operations in breast cancer survivors. The medical records of patients operated for different hand conditions after prior breast surgery and ALND at our institution between 1983 and 2002 were reviewed. The techniques and preventive measures performed, use of antibiotics, and upper extremity complications associated with the operations were analyzed. Overall, we operated on 27 patients after prior ALND performed for breast cancer. Follow-up was available for 25 patients. Four patients had pre-existing lymphedema. The surgical technique used was similar to that performed in patients without prior ALND and antibiotic prophylaxis was not given. Delayed wound healing was observed in one patient and finger joint stiffness in another. Two patients with pre-existing lymphedema developed temporary worsening of their condition. None of the patients developed new lymphedema. The results of the present study support the few previous studies, suggesting that hand surgery can be safely performed in patients with prior ALND. Based on these findings, the appropriateness of the rigorous precautions and prohibitions regarding the care and use of the ipsilateral upper extremity may need to be reconsidered.

  8. 42 CFR 84.84 - Hand-operated valves; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  9. 42 CFR 84.84 - Hand-operated valves; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  10. 42 CFR 84.84 - Hand-operated valves; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  11. 42 CFR 84.84 - Hand-operated valves; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  12. 42 CFR 84.84 - Hand-operated valves; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Hand-operated valves; minimum requirements. 84.84 Section 84.84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  13. The effect of carrier strontium on the absorption of oral doses of radioactive strontium in rats

    PubMed Central

    Harrison, G. E.; Jones, H. G.; Sutton, A.

    1957-01-01

    Carrier strontium had relatively little effect on the retention of an oral dose of radioactive strontium by the rat when it was administered immediately after the radioactive dose. The proportion of the radioactive dose which was excreted in the urine, on the other hand, increased progressively with the carrier dose. There was a decreased uptake of radioactive strontium in rats fed on a special low strontium diet. The effects of dietary strontium are discussed. Evidence was found of a discrimination by the rat against strontium in favour of calcium which was accounted for, at least in part, by a preferential urinary excretion of strontium. PMID:13460240

  14. Evaluation of Patients' Satisfaction and Functional Outcome of Dorsal Hand Unit Reconstruction in Burn Patients in Shiraz, Southern Iran.

    PubMed

    Mohammadi, Ali Akbar; Foroutan, Ali; Mohammadi, Soheil; Zardosht, Mitra

    2018-06-13

    The aim of this study was to assess patients' satisfaction and functional outcome of dorsal hand unit reconstruction in burn patients in Shiraz, southern Iran.From September 2013 to February 2017, 11 patients (15 hands) with hand aesthetic complaint who were unhappy with their hand appearance were included for dorsal hand unit reconstruction. Under general anesthesia and tourniquet control, the burned tissue on dorsal surface of the hands was excised and a thick partial thickness skin graft was used for coverage, whereas the fingers were fixed by sutures to the palm. After 1 year, the five-points scale was used for evaluation of patients' satisfaction regarding the five major activities considered for hand function before and after operation. The mean age of the patients was 25.8 ± 5.17 years. The skin grafts were well taken. Six (40%) and eight patients (53%) reported the result of operation as completely satisfied and satisfied, respectively. Dorsal hand unit reconstruction in patients with dorsal hand contracture and significant dorsal scar was shown to simultaneously improve the function and aesthetic outcome of the surgery.

  15. [The musician's hand: aspects of music physiology and performing arts medicine].

    PubMed

    Blum, J

    2000-09-01

    Musicians are particularly demanding hand patients. Increased expectancy towards the hand surgeon as well as principle aversion to any kind of operative treatment of the musician's hand impede the relationship between hand surgeon and patient. Knowledge and experience of the specific demands towards the musician's hand--including the background of basics in physiology of music making and instrumental techniques--facilitate history taking, examinations, diagnosing as well as the selection of therapy. Besides tendinitis and tendovaginitis, pathologies of the musician's hand are not more frequent compared to the entire population. Still several pathologies reach a significantly pronounced importance through the specific professional requirements. This is true especially for peripheral nerve compression syndromes, arthritis, ganglia, contractures, joint laxity and focal dystonias. The treatment of these disorders and hand trauma require, besides an utmost of hand surgical care, creativity and the implementation of the professional musical surroundings in therapy and rehabilitation, including also the musical instruments. The indication for surgery might be restrained in certain cases, although there are, without doubt, situations, when a professional musician should be operated on at an early stage. This should enhance a rapid return to play the musical instrument and to exercise delicate and demanding skilled movement patterns of his hand.

  16. Safety and pharmacokinetics of novel selective vascular endothelial growth factor receptor-2 inhibitor YN968D1 in patients with advanced malignancies

    PubMed Central

    2010-01-01

    Background YN968D1 (Apatinib) selectively inhibits phosphorylation of VEGFR-2 and tumor angiogenesis in mice model. The study was conducted to determine the maximum tolerated dose (MTD), safety profile, pharmacokinetic variables, and antitumor activity in advanced solid malignancies. Methods This dose-escalation study was conducted according to the Chinese State Food and Drug Administration (SFDA) recommendations in patients with advanced solid tumors to determine the MTD for orally administered apatinib. Doses of continuously administered apatinib were escalated from 250 mg. Treatment continued after dose-escalation phase until withdrawal of consent, intolerable toxicities, disease progression or death. Results Forty-six patients were enrolled. Hypertension and hand-foot syndrome were the two dose-limiting toxicities noted at dose level of 1000 mg. MTD was determined to be 850 mg once daily. Pharmacokinetic analysis showed early absorption with a half-life of 9 hours. The mean half-life was constant over all dose groups. Steady-state conditions analysis suggested no accumulation during 56 days of once-daily administration. The most frequently observed drug-related adverse events were hypertension (69.5%, 29 grade 1-2 and 3 grade 3-4), proteinuria (47.8%, 16 grade 1-2 and 6 grade 3-4), and hand-foot syndrome (45.6%, 15 grade 1-2 and 6 grade 3-4). Among the thirty-seven evaluable patients, PR was noted in seven patients (18.9%), SD 24 (64.9%), with a disease control rate of 83.8% at 8 weeks. Conclusions The recommended dose of 750 mg once daily was well tolerated. Encouraging antitumor activity across a broad range of malignancies warrants further evaluation in selected populations. Trial registration ClinicalTrials.gov unique identifier: NCT00633490 PMID:20923544

  17. [Late results following surgical correction of syndactyly and symbrachydactyly].

    PubMed

    Deutinger, M; Mandl, H; Frey, M; Holle, J; Freilinger, G

    1989-02-01

    Growth and the type of surgical treatment of the hand play an important role in the results of surgery in children. 29 patients have been operated on because of syndactyly and symbrachydactyly and were controlled. The following parameters were assessed: kind of incision and skin graft, functional results, x-ray to examine the skeleton and the depth of the commissure, colour of the skin graft and use of the hand. After operation of syndactyly all patients were able to use their hands normally, although full extend of flexion and extension was achieved only in 20 of 22 hands. In 5 divided pairs of fingers there was recurrence of syndactyly. In all cases except one, a split thickness skin graft has been used. After operative treatment of symbrachydactyly and complex syndactyly, full extent of flexion was achieved in 13 of 19 hands, in 6 hands the range of flexion was incomplete because of skeleton abnormalities. Recurrence occurred in 9 divided pairs of fingers; in 7 cases, a split thickness skin graft had been used. Despite this, all patients were able to use their hands normally. The use of split thickness skin grafts resulted in a 60% recurrence rate, whereas the use of full thickness skin graft led merely to 7.5% recurrence rate. Our results show the advantage of the full thickness skin graft. As a consequence, full thickness skin graft should be used in all cases. Furthermore, the operation should be performed at an early age, if fingers of unequal length have to be separated. Zig-zag incision should be used in all cases.

  18. Kinematic control of robot with degenerate wrist

    NASA Technical Reports Server (NTRS)

    Barker, L. K.; Moore, M. C.

    1984-01-01

    Kinematic resolved rate equations allow an operator with visual feedback to dynamically control a robot hand. When the robot wrist is degenerate, the computed joint angle rates exceed operational limits, and unwanted hand movements can result. The generalized matrix inverse solution can also produce unwanted responses. A method is introduced to control the robot hand in the region of the degenerate robot wrist. The method uses a coordinated movement of the first and third joints of the robot wrist to locate the second wrist joint axis for movement of the robot hand in the commanded direction. The method does not entail infinite joint angle rates.

  19. Intelligent, self-contained robotic hand

    DOEpatents

    Krutik, Vitaliy; Doo, Burt; Townsend, William T.; Hauptman, Traveler; Crowell, Adam; Zenowich, Brian; Lawson, John

    2007-01-30

    A robotic device has a base and at least one finger having at least two links that are connected in series on rotary joints with at least two degrees of freedom. A brushless motor and an associated controller are located at each joint to produce a rotational movement of a link. Wires for electrical power and communication serially connect the controllers in a distributed control network. A network operating controller coordinates the operation of the network, including power distribution. At least one, but more typically two to five, wires interconnect all the controllers through one or more joints. Motor sensors and external world sensors monitor operating parameters of the robotic hand. The electrical signal output of the sensors can be input anywhere on the distributed control network. V-grooves on the robotic hand locate objects precisely and assist in gripping. The hand is sealed, immersible and has electrical connections through the rotary joints for anodizing in a single dunk without masking. In various forms, this intelligent, self-contained, dexterous hand, or combinations of such hands, can perform a wide variety of object gripping and manipulating tasks, as well as locomotion and combinations of locomotion and gripping.

  20. Web-based interactive drone control using hand gesture

    NASA Astrophysics Data System (ADS)

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  1. Vision-Based Pose Estimation for Robot-Mediated Hand Telerehabilitation

    PubMed Central

    Airò Farulla, Giuseppe; Pianu, Daniele; Cempini, Marco; Cortese, Mario; Russo, Ludovico O.; Indaco, Marco; Nerino, Roberto; Chimienti, Antonio; Oddo, Calogero M.; Vitiello, Nicola

    2016-01-01

    Vision-based Pose Estimation (VPE) represents a non-invasive solution to allow a smooth and natural interaction between a human user and a robotic system, without requiring complex calibration procedures. Moreover, VPE interfaces are gaining momentum as they are highly intuitive, such that they can be used from untrained personnel (e.g., a generic caregiver) even in delicate tasks as rehabilitation exercises. In this paper, we present a novel master–slave setup for hand telerehabilitation with an intuitive and simple interface for remote control of a wearable hand exoskeleton, named HX. While performing rehabilitative exercises, the master unit evaluates the 3D position of a human operator’s hand joints in real-time using only a RGB-D camera, and commands remotely the slave exoskeleton. Within the slave unit, the exoskeleton replicates hand movements and an external grip sensor records interaction forces, that are fed back to the operator-therapist, allowing a direct real-time assessment of the rehabilitative task. Experimental data collected with an operator and six volunteers are provided to show the feasibility of the proposed system and its performances. The results demonstrate that, leveraging on our system, the operator was able to directly control volunteers’ hands movements. PMID:26861333

  2. Web-based interactive drone control using hand gesture.

    PubMed

    Zhao, Zhenfei; Luo, Hao; Song, Guang-Hua; Chen, Zhou; Lu, Zhe-Ming; Wu, Xiaofeng

    2018-01-01

    This paper develops a drone control prototype based on web technology with the aid of hand gesture. The uplink control command and downlink data (e.g., video) are transmitted by WiFi communication, and all the information exchange is realized on web. The control command is translated from various predetermined hand gestures. Specifically, the hardware of this friendly interactive control system is composed by a quadrotor drone, a computer vision-based hand gesture sensor, and a cost-effective computer. The software is simplified as a web-based user interface program. Aided by natural hand gestures, this system significantly reduces the complexity of traditional human-computer interaction, making remote drone operation more intuitive. Meanwhile, a web-based automatic control mode is provided in addition to the hand gesture control mode. For both operation modes, no extra application program is needed to be installed on the computer. Experimental results demonstrate the effectiveness and efficiency of the proposed system, including control accuracy, operation latency, etc. This system can be used in many applications such as controlling a drone in global positioning system denied environment or by handlers without professional drone control knowledge since it is easy to get started.

  3. Intravenous glucose preparation as the source of an outbreak of extended-spectrum beta-lactamase-producing Klebsiella pneumoniae infections in the neonatal unit of a regional hospital in KwaZulu-Natal.

    PubMed

    Moodley, Prashini; Coovadia, Yacoob M; Sturm, A Willem

    2005-11-01

    In the last week of May 2005, staff at Mahatma Gandhi Memorial Hospital in KwaZulu-Natal realised that many babies in the high-care nursery ward had bloodstream infections involving Klebsiella pneumoniae bacteria. Attempts to identify a common source of infection failed. The ward was therefore closed and new babies needing high care were admitted to another empty ward. Despite this, babies still became infected. This resulted in a request for assistance from the Department of Medical Microbiology of the Nelson R Mandela School of Medicine. A search for common factors through case history studies of the 26 infected babies showed that blood cultures of the babies remained positive despite the administration of appropriate antibiotics. Different options that could explain this were investigated. The organism was found in intravenous glucose preparations used for multiple dosing. Unopened vials of the same medication were sterile. The nursery was found to lack proper hand-wash facilities and to be overcrowded and understaffed. Reinforcement of hand hygiene and a ban on the multiple dosing of medicines stopped the outbreak. In conclusion, this outbreak resulted from a combination of factors among which lack of hand hygiene and multiple dosing of an intravenous glucose preparation were most significant.

  4. The role of single-shot metronidazole in the prevention of Clostridium difficile infection following ileostomy reversal surgery.

    PubMed

    Fernandes, Roland; Robinson, Paul; Rangarajan, Karan; Scott, Sophie; Angco, Laura

    2017-05-01

    Symptomatic infection with Clostridium difficile is strongly linked to antibiotic use and rates are higher for colorectal surgery. In February 2015, trust policy for antibiotic prophylaxis of ileostomy reversal surgery was changed from three doses of metronidazole plus cefuroxime to single-dose metronidazole, in a bid to reduce rates of Clostridium difficile infection. A retrospective cohort study was conducted at a single, large hospital trust between February 2014 and February 2016, before and after change in antimicrobial policy. Theatre data, clinical notes and pathology results were all reviewed. Outcome data, patient age, gender, length of operation and hospital stay were extracted. One hundred three patients underwent ileostomy reversal surgery between February 2014 and February 2015. All received cefuroxime together with metronidazole at induction of anaesthesia followed by two further post-operative doses as operative prophylaxis. Ninety-six patients underwent ileostomy reversal surgery between February 2015 and February 2016. All received single-dose metronidazole at induction as prophylaxis. Post-operative diarrhoea was significantly reduced in patients given single-dose metronidazole compared with patients managed with multiple dose, dual antibiotic therapy (32 vs 12.5%, P 0.001). Rates of CDI were also significantly reduced in patients given single-dose metronidazole (6.8 vs 1%, P 0.038). Single-dose, pre-operative metronidazole is effective at reducing post-operative diarrhoea and CDI in ileostomy reversal surgery compared with multiple-dose cefuroxime plus metronidazole. Metronidazole may be effective as a prophylactic antibiotic against CDI in colonic surgery.

  5. STS-33 MS Carter operates translation hand control (THC) on aft flight deck

    NASA Image and Video Library

    1989-11-27

    STS033-93-011 (27 Nov 1989) --- Astronaut Manley L. Carter, Jr., STS-33 mission specialist, operates translation hand control (THC) at the aft flight deck on orbit station while peering out overhead window W7. Carter's communications kit assembly headset microphone extends across his face.

  6. 48 CFR 218.201 - Contingency operation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... hours of business related courses do not apply to DoD employees or members of the armed forces who are....7002, Restrictions on food, clothing, fabrics, specialty metals, and hand or measuring tools: (1... hand or measuring tools in support of contingency operations, or for which the use of other than...

  7. 48 CFR 218.201 - Contingency operation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... hours of business related courses do not apply to DoD employees or members of the armed forces who are....7002, Restrictions on food, clothing, fabrics, specialty metals, and hand or measuring tools: (1... hand or measuring tools in support of contingency operations, or for which the use of other than...

  8. (99m)Tc-MDP bone scintigraphy of the hand: comparing the use of novel cadmium zinc telluride (CZT) and routine NaI(Tl) detectors.

    PubMed

    Koulikov, Victoria; Lerman, Hedva; Kesler, Mikhail; Even-Sapir, Einat

    2015-12-01

    Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in the field of nuclear medicine in cardiology and breast imaging. The aim of the current study was to evaluate the performance of the novel detectors (CZT) compared to that of the routine NaI(Tl) in bone scintigraphy. A dual-headed CZT-based camera dedicated originally to breast imaging has been used, and in view of the limited size of the detectors, the hands were chosen as the organ for assessment. This is a clinical study. Fifty-eight consecutive patients (total 116 hands) referred for bone scan for suspected hand pathology gave their informed consent to have two acquisitions, using the routine camera and the CZT-based camera. The latter was divided into full-dose full-acquisition time (FD CZT) and reduced-dose short-acquisition time (RD CZT) on CZT technology, so three image sets were available for analysis. Data analysis included comparing the detection of hot lesions and identification of the metacarpophalangeal, proximal interphalangeal, and distal interphalangeal joints. A total of 69 hot lesions were detected on the CZT image sets; of these, 61 were identified as focal sites of uptake on NaI(Tl) data. On FD CZT data, 385 joints were identified compared to 168 on NaI(Tl) data (p < 0.001). There was no statistically significant difference in delineation of joints between FD and RD CZT data as the latter identified 383 joints. Bone scintigraphy using a CZT-based gamma camera is associated with improved lesion detection and anatomic definition. The superior physical characteristics of this technique raised a potential reduction in administered dose and/or acquisition time without compromising image quality.

  9. Cognitive and Behavioral Impairments Evoked by Low-Level Exposure to Tobacco Smoke Components: Comparison with Nicotine Alone.

    PubMed

    Hall, Brandon J; Cauley, Marty; Burke, Dennis A; Kiany, Abtin; Slotkin, Theodore A; Levin, Edward D

    2016-06-01

    Active maternal smoking has adverse effects on neurobehavioral development of the offspring, with nicotine (Nic) providing much of the underlying causative mechanism. To determine whether the lower exposures caused by second-hand smoke are deleterious, we administered tobacco smoke extract (TSE) to pregnant rats starting preconception and continued through the second postnatal week, corresponding to all 3 trimesters of fetal brain development. Dosing was adjusted to produce maternal plasma Nic concentrations encountered with second-hand smoke, an order of magnitude below those seen in active smokers. We then compared TSE effects to those of an equivalent dose of Nic alone, and to a 10-fold higher Nic dose. Gestational exposure to TSE and Nic significantly disrupted cognitive and behavioral function in behavioral tests given during adolescence and adulthood (postnatal weeks 4-40), producing hyperactivity, working memory deficits, and impairments in emotional processing, even at the low exposure levels corresponding to second-hand smoke. Although TSE effects were highly correlated with those of Nic, the effects of TSE were much larger than could be attributed to just the Nic in the mixture. Indeed, TSE effects more closely resembled those of the 10-fold higher Nic levels, but still exceeded their magnitude. In combination with our earlier findings, this study thus completes the chain of causation to prove that second-hand smoke exposure causes neurodevelopmental deficits, originating in disruption of neurodifferentiation, leading to miswiring of neuronal circuits, and as shown here, culminating in behavioral dysfunction. As low level exposure to Nic alone produced neurobehavioral teratology, 'harm reduction' Nic products do not abolish the potential for neurodevelopmental damage. © The Author 2016. Published by Oxford University Press on behalf of the Society of Toxicology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  10. Octanoic acid in alcohol-responsive essential tremor

    PubMed Central

    McCrossin, Gayle; Lungu, Codrin; Considine, Elaine; Toro, Camilo; Nahab, Fatta B.; Auh, Sungyoung; Buchwald, Peter; Grimes, George J.; Starling, Judith; Potti, Gopal; Scheider, Linda; Kalowitz, Daniel; Bowen, Daniel; Carnie, Andrea; Hallett, Mark

    2013-01-01

    Objective: To assess safety and efficacy of an oral, single, low dose of octanoic acid (OA) in subjects with alcohol-responsive essential tremor (ET). Methods: We conducted a double-blind, placebo-controlled, crossover, phase I/II clinical trial evaluating the effect of 4 mg/kg OA in 19 subjects with ET. The primary outcome was accelerometric postural tremor power of the dominant hand 80 minutes after administration. Secondary outcomes included digital spiral analysis, pharmacokinetic sampling, as well as safety measures. Results: OA was safe and well tolerated. Nonserious adverse events were mild (Common Terminology Criteria for Adverse Events grade 1) and equally present after OA and placebo. At the primary outcome, OA effects were not different from placebo. Secondary outcome analyses of digital spiral analysis, comparison across the entire time course in weighted and nonweighted accelerometry, as well as nondominant hand tremor power did not show a benefit of OA over placebo. The analysis of individual time points showed that OA improved tremor at 300 minutes (dominant hand, F1,16 = 5.49, p = 0.032 vs placebo), with a maximum benefit at 180 minutes after OA (both hands, F1,16 = 6.1, p = 0.025). Conclusions: Although the effects of OA and placebo at the primary outcome were not different, secondary outcome measures suggest superiority of OA in reducing tremor at later time points, warranting further trials at higher dose levels. Classification of evidence: This study provides Class I evidence that a single 4-mg/kg dose of OA is not effective in reducing postural tremor in patients with ET at a primary outcome of 80 minutes, but is effective for a secondary outcome after 180 minutes. PMID:23408867

  11. Project CHECO Southeast Asia Report. Ranch Hand: Herbicide Operations in SEA

    DTIC Science & Technology

    1971-07-13

    Fortunately, the value of collecting and documenting our SEA expe-Uriences was recognized at an early date. In 1962 , Hq USAF directed CINCPACAF to...January 1962 to carry out the specific operations plan published the previous month, code named Sillm bI I "Ranch Hand." The first Ranch Hand aircraft...flew missions from 12 January 1962 I through 20 March 1962 . These missions were conducted along Route 15 north- 7/ west of Saigon and in the Ca Mau

  12. Hands-on Physics Education of Residents in Diagnostic Radiology.

    PubMed

    Zhang, Jie; Hardy, Peter A; DiSantis, David J; Oates, M Elizabeth

    2017-06-01

    The American Board of Radiology Core Examination integrates assessment of physics knowledge into its overall testing of clinical radiology, with an emphasis on understanding image quality and artifacts, radiation dose, and patient safety for each modality or subspecialty organ system. Accordingly, achieving a holistic approach to physics education of radiology residents is a huge challenge. The traditional teaching of radiological physics-simply through didactic lectures-was not designed for such a holistic approach. Admittedly, time constraints and clinical demands can make incorporation of physics teaching into clinical practice problematic. We created and implemented a week-long, intensive physics rotation for fledgling radiology residents and evaluated its effectiveness. The dedicated physics rotation is held for 1 week during the first month of radiology residency. It comprises three components: introductory lectures, hands-on practical clinical physics operations, and observation of clinical image production. A brief introduction of the physics pertinent to each modality is given at the beginning of each session. Hands-on experimental demonstrations are emphasized, receiving the greatest allotment of time. The residents perform experiments such as measuring radiation dose, studying the relationship between patient dose and clinical practice (eg, fluoroscopy technique), investigating the influence of acquisition parameters (kV, mAs) on radiographs, and evaluating image quality using computed tomography, magnetic resonance imaging, ultrasound, and gamma camera/single-photon emission computed tomography/positron emission tomography phantoms. Quantitative assessment of the effectiveness of the rotation is based on an examination that tests the residents' grasp of basic medical physics concepts along with written course evaluations provided by each resident. The pre- and post-rotation tests show that after the physics rotation, the average correct score of 25 questions improved from 13.6 ± 2.4 to 19 ± 1.2. The survey shows that the physics rotation during the first week of residency is favored by all residents and that 1 week's duration is appropriate. All residents are of the opinion that the intensive workshop would benefit them in upcoming clinical rotations. Residents acknowledge becoming more comfortable regarding the use of radiation and providing counsel regarding radiation during pregnancy. An immersive, short-duration, clinically oriented physics rotation is well received by new or less experienced radiology trainees, correlates basic physics concepts with their relevance to clinical imaging, and more closely parallels expectations of the American Board of Radiology Core Examination. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  13. Rheumatoid hand surgery: differing perceptions amongst surgeons, rheumatologists and therapists in the UK.

    PubMed

    Burke, F D; Miranda, S M; Owen, V M F; Bradley, M J; Sinha, S

    2011-10-01

    Rheumatoid arthritis is a systemic disease that requires coordinated management by rheumatologists, surgical specialists and therapists working in a multidisciplinary team. Differences of opinion within the team may adversely affect patient care. Our aim was to assess differences in perception about rheumatoid hand surgery between rheumatologists, hand surgeons and hand therapists in the UK. We used a postal questionnaire to assess commonly performed rheumatoid hand operations. For each procedure, respondents rated the most important indication for surgery and scored effectiveness at reducing pain, improving function and aesthetics, and preventing deformity. Statistically significant differences were found between all three groups with regards to expected outcome and main indications for surgery. We concluded that significant differences do exist in the perceptions of rheumatologists, surgeons and therapists. Rheumatoid hand operations require more detailed study, clarifying indications and outcome to allow consistent advice to patients from all members of the multidisciplinary team.

  14. Eye lens dosimetry in interventional cardiology: results of staff dose measurements and link to patient dose levels.

    PubMed

    Antic, V; Ciraj-Bjelac, O; Rehani, M; Aleksandric, S; Arandjic, D; Ostojic, M

    2013-01-01

    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 µSv for the first operator, 33 µSv for the second operator/nurse and 12 µSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 µSv Gy⁻¹ cm⁻² for the first operator, 0.33 µSv Gy⁻¹ cm⁻² for the second operator/nurse and 0.16 µSv Gy⁻¹ cm⁻² for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values.

  15. The effect of administering long-acting oxytetracycline and tilmicosin either by dart gun or by hand on injection site lesions and drug residues in beef cattle.

    PubMed Central

    Van Donkersgoed, J; VanderKop, M; Salisbury, C; Sears, L; Holowath, J

    1999-01-01

    Forty yearling cattle were injected intramuscularly with long-acting oxytetracycline and subcutaneously with tilmicosin by dart gun or by hand in a chute 28 days prior to slaughter. The drugs caused injection site lesions and antibiotic residues in the neck and thigh that varied by technique, dose, and site. PMID:12001341

  16. Evaluation of median nerve T2 signal changes in patients with surgically treated carpal tunnel syndrome.

    PubMed

    Samanci, Yavuz; Karagöz, Yeşim; Yaman, Mehmet; Atçı, İbrahim Burak; Emre, Ufuk; Kılıçkesmez, Nuri Özgür; Çelik, Suat Erol

    2016-11-01

    To determine the accuracy of median nerve T2 evaluation and its relation with Boston Questionnaire (BQ) and nerve conduction studies (NCSs) in pre-operative and post-operative carpal tunnel syndrome (CTS) patients in comparison with healthy volunteers. Twenty-three CTS patients and 24 healthy volunteers underwent NCSs, median nerve T2 evaluation and self-administered BQ. Pre-operative and 1st year post-operative median nerve T2 values and cross-sectional areas (CSAs) were compared both within pre-operative and post-operative CTS groups, and with healthy volunteers. The relationship between MRI findings and BQ and NCSs was analyzed. The ROC curve analysis was used for determining the accuracy. The comparison of pre-operative and post-operative T2 values and CSAs revealed statistically significant improvements in the post-operative patient group (p<0.001 for all parameters). There were positive correlations between T2 values at all levels and BQ values, and positive and negative correlations were also found regarding T2 values and NCS findings in CTS patients. The receiver operating characteristic curve analysis for defined cut-off levels of median nerve T2 values in hands with severe CTS yielded excellent accuracy at all levels. However, this accuracy could not be demonstrated in hands with mild CTS. This study is the first to analyze T2 values in both pre-operative and post-operative CTS patients. The presence of increased T2 values in CTS patients compared to controls and excellent accuracy in hands with severe CTS indicates T2 signal changes related to CTS pathophysiology and possible utilization of T2 signal evaluation in hands with severe CTS. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. User Performance Evaluation of Four Blood Glucose Monitoring Systems Applying ISO 15197:2013 Accuracy Criteria and Calculation of Insulin Dosing Errors.

    PubMed

    Freckmann, Guido; Jendrike, Nina; Baumstark, Annette; Pleus, Stefan; Liebing, Christina; Haug, Cornelia

    2018-04-01

    The international standard ISO 15197:2013 requires a user performance evaluation to assess if intended users are able to obtain accurate blood glucose measurement results with a self-monitoring of blood glucose (SMBG) system. In this study, user performance was evaluated for four SMBG systems on the basis of ISO 15197:2013, and possibly related insulin dosing errors were calculated. Additionally, accuracy was assessed in the hands of study personnel. Accu-Chek ® Performa Connect (A), Contour ® plus ONE (B), FreeStyle Optium Neo (C), and OneTouch Select ® Plus (D) were evaluated with one test strip lot. After familiarization with the systems, subjects collected a capillary blood sample and performed an SMBG measurement. Study personnel observed the subjects' measurement technique. Then, study personnel performed SMBG measurements and comparison measurements. Number and percentage of SMBG measurements within ± 15 mg/dl and ± 15% of the comparison measurements at glucose concentrations < 100 and ≥ 100 mg/dl, respectively, were calculated. In addition, insulin dosing errors were modelled. In the hands of lay-users three systems fulfilled ISO 15197:2013 accuracy criteria with the investigated test strip lot showing 96% (A), 100% (B), and 98% (C) of results within the defined limits. All systems fulfilled minimum accuracy criteria in the hands of study personnel [99% (A), 100% (B), 99.5% (C), 96% (D)]. Measurements with all four systems were within zones of the consensus error grid and surveillance error grid associated with no or minimal risk. Regarding calculated insulin dosing errors, all 99% ranges were between dosing errors of - 2.7 and + 1.4 units for measurements in the hands of lay-users and between - 2.5 and + 1.4 units for study personnel. Frequent lay-user errors were not checking the test strips' expiry date and applying blood incorrectly. Data obtained in this study show that not all available SMBG systems complied with ISO 15197:2013 accuracy criteria when measurements were performed by lay-users. The study was registered at ClinicalTrials.gov (NCT02916576). Ascensia Diabetes Care Deutschland GmbH.

  18. Shielding Calculations on Waste Packages - The Limits and Possibilities of different Calculation Methods by the example of homogeneous and inhomogeneous Waste Packages

    NASA Astrophysics Data System (ADS)

    Adams, Mike; Smalian, Silva

    2017-09-01

    For nuclear waste packages the expected dose rates and nuclide inventory are beforehand calculated. Depending on the package of the nuclear waste deterministic programs like MicroShield® provide a range of results for each type of packaging. Stochastic programs like "Monte-Carlo N-Particle Transport Code System" (MCNP®) on the other hand provide reliable results for complex geometries. However this type of program requires a fully trained operator and calculations are time consuming. The problem here is to choose an appropriate program for a specific geometry. Therefore we compared the results of deterministic programs like MicroShield® and stochastic programs like MCNP®. These comparisons enable us to make a statement about the applicability of the various programs for chosen types of containers. As a conclusion we found that for thin-walled geometries deterministic programs like MicroShield® are well suited to calculate the dose rate. For cylindrical containers with inner shielding however, deterministic programs hit their limits. Furthermore we investigate the effect of an inhomogeneous material and activity distribution on the results. The calculations are still ongoing. Results will be presented in the final abstract.

  19. Right-handed charged currents in the era of the Large Hadron Collider

    DOE PAGES

    Alioli, Simone; Cirigliano, Vincenzo; Dekens, Wouter Gerard; ...

    2017-05-16

    We discuss the phenomenology of right-handed charged currents in the frame-work of the Standard Model Effective Field Theory, in which they arise due to a single gauge-invariant dimension-six operator. We study the manifestations of the nine complex couplings of the W to right-handed quarks in collider physics, flavor physics, and low-energy precision measurements. We first obtain constraints on the couplings under the assumption that the right-handed operator is the dominant correction to the Standard Model at observable energies. Here, we subsequently study the impact of degeneracies with other Beyond-the-Standard-Model effective interactions and identify observables, both at colliders and low-energy experiments,more » that would uniquely point to right-handed charged currents.« less

  20. Dose inspection and risk assessment on radiation safety for the use of non-medical X-ray machines in Taiwan

    NASA Astrophysics Data System (ADS)

    Hsu, Fang-Yuh; Hsu, Shih-Ming; Chao, Jiunn-Hsing

    2017-11-01

    The subject of this study is the on-site visits and inspections of facilities commissioned by the Atomic Energy Council (AEC) in Taiwan. This research was conducted to evaluate the possible dose and dose rate of cabinet-type X-ray equipment with nominal voltages of 30-150 kV and open-beam (portable or handheld) equipment, taking both normal operation and possibly abnormal operation conditions into account. Doses and dose rates were measured using a plastic scintillation survey meter and an electronic personal dosimeter. In total, 401 X-ray machines were inspected, including 139 units with nominal voltages of 30-50 kV X-ray equipment, 140 units with nominal voltages of 50-150 kV, and 122 open-beam (portable or handheld) X-ray equipment. The investigated doses for radiation workers and non-radiation workers operating cabinet-type X-ray equipment under normal safety conditions were all at the background dose level. Several investigated dose rates at the position of 10 cm away from the surface of open-beam (portable or handheld) X-ray equipment were very high, such X-ray machines are used by aeronautical police for the detection of suspected explosives, radiation workers are far away (at least 10 m away) from the X-ray machine during its operation. The doses per operation in X-ray equipment with a 30-50 kV nominal voltage were less than 1 mSv in all cases of abnormal use. Some doses were higher than 1 mSv per operation for X-ray equipment of 50-150 kV nominal voltage X-ray. The maximum dose rates at the beam exit have a very wide range, mostly less than 100 μSv/s and the largest value is about 3.92 mSv/s for open-beam (portable or handheld) X-ray devices. The risk induced by operating X-ray devices with nominal voltages of 30-50 kV is extremely low. The 11.5 mSv dose due to one operation at nominal voltage of 50-150 kV X-ray device is equivalent to the exposure of taking 575 chest X-rays. In the abnormal use of open-beam (portable or handheld) X-ray equipment, the effective dose of 3.92 mSv/s is equivalent to taking 196 chest radiographs within 1 s. This work assessed the annual doses (equivalent and effective doses) and risks of X-ray operator staff as reasonably as possible. The results of this research are helpful to the AEC (competent authority of ionization radiation) to improve the management and perform the safe control of X-ray equipment.

  1. Hand washing frequencies and procedures used in retail food services.

    PubMed

    Strohbehn, Catherine; Sneed, Jeannie; Paez, Paola; Meyer, Janell

    2008-08-01

    Transmission of viruses, bacteria, and parasites to food by way of improperly washed hands is a major contributing factor in the spread of foodborne illnesses. Field observers have assessed compliance with hand washing regulations, yet few studies have included consideration of frequency and methods used by sectors of the food service industry or have included benchmarks for hand washing. Five 3-h observation periods of employee (n = 80) hand washing behaviors during menu production, service, and cleaning were conducted in 16 food service operations for a total of 240 h of direct observation. Four operations from each of four sectors of the retail food service industry participated in the study: assisted living for the elderly, childcare, restaurants, and schools. A validated observation form, based on 2005 Food Code guidelines, was used by two trained researchers. Researchers noted when hands should have been washed, when hands were washed, and how hands were washed. Overall compliance with Food Code recommendations for frequency during production, service, and cleaning phases ranged from 5% in restaurants to 33% in assisted living facilities. Procedural compliance rates also were low. Proposed benchmarks for the number of times hand washing should occur by each employee for each sector of food service during each phase of operation are seven times per hour for assisted living, nine times per hour for childcare, 29 times per hour for restaurants, and 11 times per hour for schools. These benchmarks are high, especially for restaurant employees. Implementation would mean lost productivity and potential for dermatitis; thus, active managerial control over work assignments is needed. These benchmarks can be used for training and to guide employee hand washing behaviors.

  2. Randomized crossover study evaluating the effect of a hand sanitizer dispenser on the frequency of hand hygiene among anesthesiology staff in the operating room.

    PubMed

    Munoz-Price, L Silvia; Patel, Zalak; Banks, Shawn; Arheart, Kristopher; Eber, Scott; Lubarsky, David A; Birnbach, David J

    2014-06-01

    Forty anesthesia providers were evaluated with and without hand sanitizer dispensers present on the anesthesia machine. Having a dispenser increased the frequency of hand hygiene only from 0.5 to 0.8 events per hour (P = .01). Other concomitant interventions are needed to further increase hand hygiene frequency among anesthesia providers.

  3. Validation of clinical testing for warfarin sensitivity: comparison of CYP2C9-VKORC1 genotyping assays and warfarin-dosing algorithms.

    PubMed

    Langley, Michael R; Booker, Jessica K; Evans, James P; McLeod, Howard L; Weck, Karen E

    2009-05-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 -1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses.

  4. Texture Analysis and Machine Learning for Detecting Myocardial Infarction in Noncontrast Low-Dose Computed Tomography: Unveiling the Invisible.

    PubMed

    Mannil, Manoj; von Spiczak, Jochen; Manka, Robert; Alkadhi, Hatem

    2018-06-01

    The aim of this study was to test whether texture analysis and machine learning enable the detection of myocardial infarction (MI) on non-contrast-enhanced low radiation dose cardiac computed tomography (CCT) images. In this institutional review board-approved retrospective study, we included non-contrast-enhanced electrocardiography-gated low radiation dose CCT image data (effective dose, 0.5 mSv) acquired for the purpose of calcium scoring of 27 patients with acute MI (9 female patients; mean age, 60 ± 12 years), 30 patients with chronic MI (8 female patients; mean age, 68 ± 13 years), and in 30 subjects (9 female patients; mean age, 44 ± 6 years) without cardiac abnormality, hereafter termed controls. Texture analysis of the left ventricle was performed using free-hand regions of interest, and texture features were classified twice (Model I: controls versus acute MI versus chronic MI; Model II: controls versus acute and chronic MI). For both classifications, 6 commonly used machine learning classifiers were used: decision tree C4.5 (J48), k-nearest neighbors, locally weighted learning, RandomForest, sequential minimal optimization, and an artificial neural network employing deep learning. In addition, 2 blinded, independent readers visually assessed noncontrast CCT images for the presence or absence of MI. In Model I, best classification results were obtained using the k-nearest neighbors classifier (sensitivity, 69%; specificity, 85%; false-positive rate, 0.15). In Model II, the best classification results were found with the locally weighted learning classification (sensitivity, 86%; specificity, 81%; false-positive rate, 0.19) with an area under the curve from receiver operating characteristics analysis of 0.78. In comparison, both readers were not able to identify MI in any of the noncontrast, low radiation dose CCT images. This study indicates the ability of texture analysis and machine learning in detecting MI on noncontrast low radiation dose CCT images being not visible for the radiologists' eye.

  5. Dose-response patterns for vibration-induced white finger

    PubMed Central

    Griffin, M; Bovenzi, M; Nelson, C

    2003-01-01

    Aims: To investigate alternative relations between cumulative exposures to hand-transmitted vibration (taking account of vibration magnitude, lifetime exposure duration, and frequency of vibration) and the development of white finger (Raynaud's phenomenon). Methods: Three previous studies have been combined to provide a group of 1557 users of powered vibratory tools in seven occupational subgroups: stone grinders, stone carvers, quarry drillers, dockyard caulkers, dockyard boilermakers, dockyard painters, and forest workers. The estimated total operating duration in hours was thus obtained for each subject, for each tool, and for all tools combined. From the vibration magnitudes and exposure durations, seven alternative measurements of cumulative exposure were calculated for each subject, using expressions of the form: dose = ∑amiti, where ai is the acceleration magnitude on tool i, ti is the lifetime exposure duration for tool i, and m = 0, 1, 2, or 4. Results: For all seven alternative dose measures, an increase in dose was associated with a significant increase in the occurrence of vibration-induced white finger, after adjustment for age and smoking. However, dose measures with high powers of acceleration (m > 1) faired less well than measures in which the weighted or unweighted acceleration, and lifetime exposure duration, were given equal weight (m = 1). Dose determined solely by the lifetime exposure duration (without consideration of the vibration magnitude) gave better predictions than measures with m greater than unity. All measures of dose calculated from the unweighted acceleration gave better predictions than the equivalent dose measures using acceleration frequency-weighted according to current standards. Conclusions: Since the total duration of exposure does not discriminate between exposures accumulated over the day and those accumulated over years, a linear relation between vibration magnitude and exposure duration seems appropriate for predicting the occurrence of vibration-induced white finger. Poorer predictions were obtained when the currently recommended frequency weighting was employed than when accelerations at all frequencies were given equal weight. Findings suggest that improvements are possible to both the frequency weighting and the time dependency used to predict the development of vibration-induced white finger in current standards. PMID:12499452

  6. Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool.

    PubMed

    Brady, S L; Kaufman, R A

    2015-05-01

    To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k air) value based on an x-ray characteristic radiation output curve; (2) scaling k air with a BSF value; and (3) correcting k air for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass-energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19-0.42 mGy for dual view chest, 0.28-1.2 mGy for AP abdomen, 0.18-0.65 mGy for LAT view skull, 0.15-0.63 mGy for dual view knee, and 0.10-0.12 mGy for bone age (left hand) examinations. A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.

  7. Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brady, S. L., E-mail: samuel.brady@stjude.org; Kaufman, R. A., E-mail: robert.kaufman@stjude.org

    Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken frommore » DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.« less

  8. Outbreaks where food workers have been implicated in the spread of foodborne disease. Part 4. Infective doses and pathogen carriage.

    PubMed

    Todd, Ewen C D; Greig, Judy D; Bartleson, Charles A; Michaels, Barry S

    2008-11-01

    In this article, the fourth in a series reviewing the role of food workers in foodborne outbreaks, background information on the presence of enteric pathogens in the community, the numbers of organisms required to initiate an infection, and the length of carriage are presented. Although workers have been implicated in outbreaks, they were not always aware of their infections, either because they were in the prodromic phase before symptoms began or because they were asymptomatic carriers. Pathogens of fecal, nose or throat, and skin origin are most likely to be transmitted by the hands, highlighting the need for effective hand hygiene and other barriers to pathogen contamination, such as no bare hand contact with ready-to-eat food. The pathogens most likely to be transmitted by food workers are norovirus, hepatitis A virus, Salmonella, Shigella, and Staphylococcus aureus. However, other pathogens have been implicated in worker-associated outbreaks or have the potential to be implicated. In this study, the likelihood of pathogen involvement in foodborne outbreaks where infected workers have been implicated was examined, based on infectious dose, carriage rate in the community, duration of illness, and length of pathogen excretion. Infectious dose estimates are based on volunteer studies (mostly early experiments) or data from outbreaks. Although there is considerable uncertainty associated with these data, some pathogens appear to be able to infect at doses as low as 1 to 100 units, including viruses, parasites, and some bacteria. Lengthy postsymptomatic shedding periods and excretion by asymptomatic individuals of many enteric pathogens is an important issue for the hygienic management of food workers.

  9. Performance evaluation of haptic hand-controllers in a robot-assisted surgical system.

    PubMed

    Zareinia, Kourosh; Maddahi, Yaser; Ng, Canaan; Sepehri, Nariman; Sutherland, Garnette R

    2015-12-01

    This paper presents the experimental evaluation of three commercially available haptic hand-controllers to evaluate which was more suitable to the participants. Two surgeons and seven engineers performed two peg-in-hole tasks with different levels of difficulty. Each operator guided the end-effector of a Kuka manipulator that held surgical forceps and was equipped with a surgical microscope. Sigma 7, HD(2) and PHANToM Premium 3.0 hand-controllers were compared. Ten measures were adopted to evaluate operators' performances with respect to effort, speed and accuracy in completing a task, operator improvement during the tests, and the force applied by each haptic device. The best performance was observed with the Premium 3.0; the hand-piece was able to be held in a similar way to that used by surgeons to hold conventional tools. Hand-controllers with a linkage structure similar to the human upper extremity take advantage of the inherent human brain connectome, resulting in improved surgeon performance during robotic-assisted surgery. Copyright © 2015 John Wiley & Sons, Ltd.

  10. 16. OPERATOR STAND. OPERATOR STOOD BETWEEN RAILINGS AND CONTROLLED DREDGING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. OPERATOR STAND. OPERATOR STOOD BETWEEN RAILINGS AND CONTROLLED DREDGING OPERATIONS USING TWO LEVERS FROM CEILING, THREE LEVELS ON THE FLOOR, AND TWO FLOOR PEDDLES. RIGHT HAND CONTROLLED SHOT GUN SWINGER (BOOM MOVE TO RIGHT WHEN PUSHED FORWARD, LEFT WHEN PULLED BACK, AND, IF LUCKY, STOPPED WHEN IN CENTER POSITION). LEFT HAND CONTROLLED THROTTLE. FLOOR LEVER AND FLOOR PEDDLE ON LEFT CONTROLLED THE BACKING LINE FRICTION. MIDDLE LEVER AND PEDDLE, STUCK IN FLOOR CONTROLLED THE MAIN HOIST FRICTION. LEVER ON RIGHT CONTROLLED THE CYLINDER DRAIN VALVE. - Dredge CINCINNATI, Docked on Ohio River at foot of Lighthill Street, Pittsburgh, Allegheny County, PA

  11. Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting.

    PubMed

    Matsui, Yusuke; Hiraki, Takao; Gobara, Hideo; Iguchi, Toshihiro; Fujiwara, Hiroyasu; Kawabata, Takahiro; Yamauchi, Takatsugu; Yamaguchi, Takuya; Kanazawa, Susumu

    2016-06-01

    Computed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking. Radiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator's finger skin was measured using thermoluminescent dosimeter rings. The mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator's finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA. Radiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

  12. Push-To-Lock, Push-To-Release Mechanism

    NASA Technical Reports Server (NTRS)

    Lozano, Anselmo, Jr.

    1991-01-01

    Latch locked or unlocked with single motion of hand. No tools needed to operate it, and user easily opens or closes it with heavily gloved hand. When unlocked, stem free of main body. In locked state, dowel pins in main body hold stem. Latch equipped with lock and key so only authorized users operate it.

  13. Process and Learning Outcomes from Remotely-Operated, Simulated, and Hands-on Student Laboratories

    ERIC Educational Resources Information Center

    Corter, James E.; Esche, Sven K.; Chassapis, Constantin; Ma, Jing; Nickerson, Jeffrey V.

    2011-01-01

    A large-scale, multi-year, randomized study compared learning activities and outcomes for hands-on, remotely-operated, and simulation-based educational laboratories in an undergraduate engineering course. Students (N = 458) worked in small-group lab teams to perform two experiments involving stress on a cantilever beam. Each team conducted the…

  14. 78 FR 36749 - Determination Under the African Growth and Opportunity Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-19

    ... Benin. Articles must be ornamented in characteristic Benin or regional folk style. An article may not... synthetic fibers. Hand-woven on manually operated looms then hand or machine stitched. There [[Page 36750...-woven in manually operated looms then machine stitched together to form a wider substrate. This is a...

  15. Efficacy of Single-dose and 2-dose Intravenous Administration of Ramosetron in Preventing Postoperative Nausea and Vomiting After Laparoscopic Gynecologic Operation: A Randomized, Double-blind, Placebo-controlled, Phase 2 Trial.

    PubMed

    Lee, Banghyun; Kim, Kidong; Suh, Dong Hoon; Shin, Hyun-Jung; No, Jae Hong; Lee, Jung Ryeol; Jee, Byung Chul; Hwang, Jung Won; Do, Sang Hwan; Kim, Yong Beom

    2017-06-01

    This randomized trial investigated whether a 2-dose administration of intravenous ramosetron (5-hydroxytryptamine type 3 receptor antagonist) is more effective than a single-dose administration in preventing postoperative nausea and vomiting (PONV) in 89 patients who were scheduled to undergo laparoscopic operation for benign gynecologic diseases and to receive intravenous patient-controlled analgesia for relief of postoperative pain. After assignment at a ratio of 1:1, intravenous ramosetron (0.3 mg) was initially administered at the end of skin closure in all patients. Thereafter, ramosetron (0.3 mg) and placebo were administered to the study and control groups, respectively, at 4 hours after the operation. The baseline and operative characteristics were similar between the groups. The incidence of PONV during the 24-hour period after operation which was assessed as the primary endpoint did not differ between the groups. No serious adverse events occurred in either group. A 2-dose administration of intravenous ramosetron may not be superior to a single-dose administration in preventing PONV in patients undergoing laparoscopic operation for benign gynecologic diseases.

  16. Shear Strength of Remoulding Clay Samples Using Different Methods of Moulding

    NASA Astrophysics Data System (ADS)

    Norhaliza, W.; Ismail, B.; Azhar, A. T. S.; Nurul, N. J.

    2016-07-01

    Shear strength for clay soil was required to determine the soil stability. Clay was known as a soil with complex natural formations and very difficult to obtain undisturbed samples at the site. The aim of this paper was to determine the unconfined shear strength of remoulded clay on different methods in moulding samples which were proctor compaction, hand operated soil compacter and miniature mould methods. All the samples were remoulded with the same optimum moisture content (OMC) and density that were 18% and 1880 kg/m3 respectively. The unconfined shear strength results of remoulding clay soils for proctor compaction method was 289.56kPa with the strain 4.8%, hand operated method was 261.66kPa with the strain 4.4% and miniature mould method was 247.52kPa with the strain 3.9%. Based on the proctor compaction method, the reduction percentage of unconfined shear strength of remoulded clay soil of hand operated method was 9.66%, and for miniature mould method was 14.52%. Thus, because there was no significant difference of reduction percentage of unconfined shear strength between three different methods, so it can be concluded that remoulding clay by hand operated method and miniature mould method were accepted and suggested to perform remoulding clay samples by other future researcher. However for comparison, the hand operated method was more suitable to form remoulded clay sample in term of easiness, saving time and less energy for unconfined shear strength determination purposes.

  17. Intensity modulated operating mode of the rotating gamma system.

    PubMed

    Sengupta, Bishwambhar; Gulyas, Laszlo; Medlin, Donald; Koroknai, Tibor; Takacs, David; Filep, Gyorgy; Panko, Peter; Godo, Bence; Hollo, Tamas; Zheng, Xiao Ran; Fedorcsak, Imre; Dobai, Jozsef; Bognar, Laszlo; Takacs, Endre

    2018-05-01

    The purpose of this work was to explore two novel operation modalities of the rotating gamma systems (RGS) that could expand its clinical application to lesions in close proximity to critical organs at risk (OAR). The approach taken in this study consists of two components. First, a Geant4-based Monte Carlo (MC) simulation toolkit is used to model the dosimetric properties of the RGS Vertex 360™ for the normal, intensity modulated radiosurgery (IMRS), and speed modulated radiosurgery (SMRS) operation modalities. Second, the RGS Vertex 360™ at the Rotating Gamma Institute in Debrecen, Hungary is used to collect experimental data for the normal and IMRS operation modes. An ion chamber is used to record measurements of the absolute dose. The dose profiles are measured using Gafchromic EBT3 films positioned within a spherical water equivalent phantom. A strong dosimetric agreement between the measured and simulated dose profiles and penumbra was found for both the normal and IMRS operation modes for all collimator sizes (4, 8, 14, and 18 mm diameter). The simulated falloff and maximum dose regions agree better with the experimental results for the 4 and 8 mm diameter collimators. Although the falloff regions align well in the 14 and 18 mm collimators, the maximum dose regions have a larger difference. For the IMRS operation mode, the simulated and experimental dose distributions are ellipsoidal, where the short axis aligns with the blocked angles. Similarly, the simulated dose distributions for the SMRS operation mode also adopt an ellipsoidal shape, where the short axis aligns with the angles where the orbital speed is highest. For both modalities, the dose distribution is highly constrained with a sharper penumbra along the short axes. Dose modulation of the RGS can be achieved with the IMRS and SMRS modes. By providing a highly constrained dose distribution with a sharp penumbra, both modes could be clinically applicable for the treatment of lesions in close proximity to critical OARs. © 2018 American Association of Physicists in Medicine.

  18. Variability in Resident Operative Hand Experience by Specialty.

    PubMed

    Silvestre, Jason; Lin, Ines C; Levin, L Scott; Chang, Benjamin

    2018-01-01

    Recent attention has sought to standardize hand surgery training in the United States. This study analyzes the variability in operative hand experience for orthopedic and general surgery residents. Case logs for orthopedic and general surgery residency graduates were obtained from the American Council of Graduate Medical Education (2006-2007 to 2014-2015). Plastic surgery case logs were not available for comparison. Hand surgery case volumes were compared between specialties with parametric tests. Intraspecialty variation in orthopedic surgery was assessed between the bottom and top 10th percentiles in procedure categories. Case logs for 9605 general surgery residents and 5911 orthopedic surgery residents were analyzed. Orthopedic surgery residents performed a greater number of hand surgery cases than general surgery residents ( P < .001). Mean total hand experience ranged from 2.5 ± 4 to 2.8 ± 5 procedures for general surgery residents with no reported cases of soft tissue repairs, vascular repairs, and replants. Significant intraspecialty variation existed in orthopedic surgery for all hand procedure categories (range, 3.3-15.0). As the model for hand surgery training evolves, general surgeons may represent an underutilized talent pool to meet the critical demand for hand surgeon specialists. Future research is needed to determine acceptable levels of training variability in hand surgery.

  19. Measurement of doses to the extremities of nuclear medicine staff

    NASA Astrophysics Data System (ADS)

    Shousha, Hany A.; Farag, Hamed; Hassan, Ramadan A.

    2010-01-01

    Medical uses of ionizing radiation now represent>95% of all man-made radiation exposure, and is the largest single radiation source after natural background radiation. Therefore, it is important to quantify the amount of radiation received by occupational individuals to optimize the working conditions for staff, and further, to compare doses in different departments to ensure compatibility with the recommended standards. For some groups working with unsealed sources in nuclear medicine units, the hands are more heavily exposed to ionizing radiation than the rest of the body. A personal dosimetry service runs extensively in Egypt. But doses to extremities have not been measured to a wide extent. The purpose of this study was to investigate the equivalent radiation doses to the fingers for five different nuclear medicine staff occupational groups for which heavy irradiation of the hands was suspected. Finger doses were measured for (1) nuclear medicine physicians, (2) technologists, (3) nurses and (4) physicists. The fifth group contains three technicians handling 131I, while the others handled 99mTc. Each staff member working with the radioactive material wore two thermoluminescent dosimeters (TLDs) during the whole testing period, which lasted from 1 to 4 weeks. Staff performed their work on a regular basis throughout the month, and mean annual doses were calculated for these groups. Results showed that the mean equivalent doses to the fingers of technologist, nurse and physicist groups were 30.24±14.5, 30.37±17.5 and 16.3±7.7 μSv/GBq, respectively. Equivalent doses for the physicians could not be calculated per unit of activity because they did not handle the radiopharmaceuticals directly. Their doses were reported in millisieverts (mSv) that accumulated in one week. Similarly, the dose to the fingers of individuals in Group 5 was estimated to be 126.13±38.2 μSv/GBq. The maximum average finger dose, in this study, was noted in the technologists who handled therapeutic 131I (2.5 mSv). In conclusion, the maximum expected annual dose to extremities is less than the annual limit (500 mSv/y).

  20. Occupational dose constraints in interventional cardiology procedures: the DIMOND approach

    NASA Astrophysics Data System (ADS)

    Tsapaki, Virginia; Kottou, Sophia; Vano, Eliseo; Komppa, Tuomo; Padovani, Renato; Dowling, Annita; Molfetas, Michael; Neofotistou, Vassiliki

    2004-03-01

    Radiation fields involved in angiographic suites are most uneven with intensity and gradient varying widely with projection geometry. The European Commission DIMOND III project addressed among others, the issues regarding optimization of staff doses with an attempt to propose preliminary occupational dose constraints. Two thermoluminescent dosemeters (TLD) were used to assess operators' extremity doses (left shoulder and left foot) during 20 coronary angiographies (CAs) and 20 percutaneous transluminal coronary angioplasties (PTCAs) in five European centres. X-ray equipment, radiation protection measures used and the dose delivered to the patient in terms of dose-area product (DAP) were recorded so as to subsequently associate them with operator's dose. The range of staff doses noted for the same TLD position, centre and procedure type emphasizes the importance of protective measures and technical characteristics of x-ray equipment. Correlation of patient's DAP with staff shoulder dose is moderate whereas correlation of patient's DAP with staff foot dose is poor in both CA and PTCA. Therefore, it is difficult to predict operator's dose from patient's DAP mainly due to the different use of protective measures. A preliminary occupational dose constraint value was defined by calculating cardiologists' annual effective dose and found to be 0.6 mSv.

  1. EYE LENS EXPOSURE TO MEDICAL STAFF PERFORMING ELECTROPHYSIOLOGY PROCEDURES: DOSE ASSESSMENT AND CORRELATION TO PATIENT DOSE.

    PubMed

    Ciraj-Bjelac, Olivera; Antic, Vojislav; Selakovic, Jovana; Bozovic, Predrag; Arandjic, Danijela; Pavlovic, Sinisa

    2016-12-01

    The purpose of this study was to assess the patient exposure and staff eye dose levels during implantation procedures for all types of pacemaker therapy devices performed under fluoroscopic guidance and to investigate potential correlation between patients and staff dose levels. The mean eye dose during pacemaker/defibrillator implementation was 12 µSv for the first operator, 8.7 µSv for the second operator/nurse and 0.50 µSv for radiographer. Corresponding values for cardiac resynchronisation therapy procedures were 30, 26 and 2.0 µSv, respectively. Significant (p < 0.01) correlation between the eye dose and the kerma-area product was found for the first operator and radiographers, but not for other staff categories. The study revealed eye dose per procedure and eye dose normalised to patient dose indices for different staff categories and provided an input for radiation protection in electrophysiology procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. RADIATION PROTECTION CABIN FOR CATHETER-DIRECTED LIVER INTERVENTIONS: OPERATOR DOSE ASSESSMENT.

    PubMed

    Maleux, Geert; Bergans, Niki; Bosmans, Hilde; Bogaerts, Ria

    2016-09-01

    The number and complexity of interventional radiological procedures and in particular catheter-directed liver interventions have increased substantially. The current study investigates the reduction of personal doses when using a dedicated radiation protection cabin (RPC) for these procedures. Operator and assistant doses were assessed for 3 series of 20 chemoinfusion/chemoembolisation interventions, including an equal number of procedures with and without RPC. Whole body doses, finger doses and doses at the level of knees and eyes were evaluated with different types of TLD-100 Harshaw dosemeters. Dosemeters were also attached on the three walls of the RPC. The operator doses were significantly reduced by the RPC, but also without RPC, the doses appear to be limited as a result of thorough optimisation with existing radiation protection tools. The added value of the RPC should thus be determined by the outcome of balancing dose reduction and other aspects such as ergonomic benefits. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. The Impact of Specialty on Cases Performed During Hand Surgery Fellowship Training.

    PubMed

    Silvestre, Jason; Upton, Joseph; Chang, Benjamin; Steinberg, David R

    2018-03-07

    Hand surgery fellowship programs in the United States are predominately sponsored by departments or divisions of orthopaedic surgery or plastic surgery. This study compares the operative experiences of hand surgery fellows graduating from orthopaedic or plastic surgery hand surgery fellowships. Operative case logs of 3 cohorts of hand surgery fellows graduating during the academic years of 2012-2013, 2013-2014, and 2014-2015 were analyzed. The median case volumes were compared by specialty via Mann-Whitney U tests. An arbitrary 1,000% change between the 90th and 10th percentiles of fellows was used as a threshold to highlight case categories with substantial variability. In this study, 413 orthopaedic hand surgery fellows (87%) and 62 plastic surgery hand surgery fellows (13%) were included. Plastic surgery fellows reported more cases in the following categories: wound closure with graft; wound reconstruction with flap; vascular repair, reconstruction, replantation, or microvascular; closed treatment of fracture or dislocation; nerve injury; and congenital (p < 0.05). Orthopaedic surgery fellows reported more cases in the following categories: wound irrigation and debridement fasciotomy or wound preparation; hand reconstruction or releases; wrist reconstruction, releases, or arthrodesis; forearm, elbow, or shoulder reconstruction or releases; hand fractures, dislocation, or ligament injury; wrist fractures or dislocations; forearm and proximal fractures or dislocations; miscellaneous insertion or removal of devices; shoulder arthroscopy, elbow arthroscopy, and wrist arthroscopy; decompression of tendon sheath, synovectomy, or ganglions; nerve decompression; Dupuytren; and tumor or osteomyelitis (p < 0.05). Plastic surgery fellows reported substantial variability for 12 case categories (range, 1,024% to 2,880%). Orthopaedic surgery fellows reported substantial variability for 9 case categories (range, 1,110% to 9,700%). Orthopaedic and plastic hand surgery fellowships afford disparate operative experiences. Understanding these differences may help to align prospective trainees with future career goals and to guide discussions to better standardize hand surgery training.

  4. Assessment of hand-transmitted vibration exposure from motorized forks used for beach-cleaning operations.

    PubMed

    McDowell, Thomas W; Welcome, Daniel E; Warren, Christopher; Xu, Xueyan S; Dong, Ren G

    2013-01-01

    Motorized vibrating manure forks were used in beach-cleaning operations following the massive Deepwater Horizon oil spill in the Gulf of Mexico during the summer of 2010. The objectives of this study were to characterize the vibration emissions of these motorized forks and to provide a first approximation of hand-transmitted vibration exposures to workers using these forks for beach cleaning. Eight operators were recruited to operate the motorized forks during this laboratory study. Four fork configurations were used in the study; two motor speeds and two fork basket options were evaluated. Accelerations were measured near each hand as the operators completed the simulated beach-cleaning task. The dominant vibration frequency for these tools was identified to be around 20 Hz. Because acceleration was found to increase with motor speed, workers should consider operating these tools with just enough speed to get the job done. These forks exhibited considerable acceleration magnitudes when unloaded. The study results suggest that the motor should not be operated with the fork in the unloaded state. Anti-vibration gloves are not effective at attenuating the vibration frequencies produced by these forks, and they may even amplify the transmitted vibration and increase hand/arm fatigue. While regular work gloves are suitable, vibration-reducing gloves may not be appropriate for use with these tools. These considerations may also be generally applicable for the use of motorized forks in other workplace environments.

  5. Dosimetric comparison between conventional and conformal radiotherapy for carcinoma cervix: Are we treating the right volumes?

    PubMed Central

    Goswami, Jyotirup; Patra, Niladri B.; Sarkar, Biplab; Basu, Ayan; Pal, Santanu

    2013-01-01

    Background and Purpose: Conventional portals, based on bony anatomy, for external beam radiotherapy for cervical cancer have been repeatedly demonstrated as inadequate. Conversely, with image-based conformal radiotherapy, better target coverage may be offset by the greater toxicities and poorer compliance associated with treating larger volumes. This study was meant to dosimetrically compare conformal and conventional radiotherapy. Materials and Methods: Five patients of carcinoma cervix underwent planning CT scan with IV contrast and targets, and organs at risk (OAR) were contoured. Two sets of plans-conventional and conformal were generated for each patient. Field sizes were recorded, and dose volume histograms of both sets of plans were generated and compared on the basis of target coverage and OAR sparing. Results: Target coverage was significantly improved with conformal plans though field sizes required were significantly larger. On the other hand, dose homogeneity was not significantly improved. Doses to the OARs (rectum, urinary bladder, and small bowel) were not significantly different across the 2 arms. Conclusion: Three-dimensional conformal radiotherapy gives significantly better target coverage, which may translate into better local control and survival. On the other hand, it also requires significantly larger field sizes though doses to the OARs are not significantly increased. PMID:24455584

  6. Microcystins from tap water could be a risk factor for liver and colorectal cancer: a risk intensified by global change.

    PubMed

    Martínez Hernández, Juan; López-Rodas, V; Costas, E

    2009-05-01

    An increasing number of people drink water from fresh water supply reservoirs. However, with the global change a lot of reservoirs become eutrophic, which facilitates the occurrence of toxin-producing cyanobacterial blooms. Microcystins (powerful hepatotoxic water-soluble heptapeptides) are the most important cyanobacterial toxins affecting humans. High doses of microcystins produce hepatic necrosis. Consequently, WHO Guidelines limit microcystins to 1 ppb in drinking waters. However, microcystins are present frequently in tap water at lower doses. Here, we hypothesized that chronic consume of tap water containing low doses of microcystins may be a risk factor for liver and colorectal cancer. Two kinds of evidences support this hypothesis. On one hand some epidemiological data (mainly in China). On the other hand, the molecular mechanism of microcystins toxicity (inhibition of protein phosphatases PP1 and PP2) is just like okadaic acid (a potent tumor promoter). Cancer risk from drinking water is certainly less than smoking, occupational exposures or some foods. But it is significant and with a rapid increase of toxic cyanobacterial blooms by eutrophycation, become more frequent.

  7. Modulation of inflammation by low and high doses of ionizing radiation: Implications for benign and malign diseases.

    PubMed

    Frey, Benjamin; Hehlgans, Stephanie; Rödel, Franz; Gaipl, Udo S

    2015-11-28

    Inflammation is a homeostatic mechanism aiming to maintain tissue integrity. The underlying immunological mechanisms and the interrelationship between ionizing radiation and inflammation are complex and multifactorial on cellular and chemical levels. On the one hand, radiation with single doses exceeding 1 Gy might initiate inflammatory reactions and thereby impact on tumor development. On the other hand, radiation is capable of attenuating an established inflammatory process, which is clinically used for the treatment of inflammatory and degenerative diseases with low-dose radiotherapy (single dose <1 Gy). At higher doses, ionizing radiation, especially in combination with additional immune stimulation, fosters the induction of immunogenic forms of tumor cell death and shifts the tumor microenvironment as well as the infiltration of immune cells from an anti- to a pro-inflammatory state. Distinct tumor infiltrating immune cells predict the response to radiochemotherapy in a multitude of tumor entities. While a high tumor infiltration of these adaptive immune cells mostly predicts a favorable disease outcome, a high infiltration of tumor-associated macrophages predicts an unfavorable response. Pro-inflammatory events should dominate over anti-inflammatory ones in this scenario. This review focuses on how ionizing radiation modulates inflammatory events in benign inflammatory and in malign diseases. A special focus is set on the role of tumor infiltrating lymphocytes and macrophages as biomarkers to predict treatment response and anti-tumor immunity and on mechanisms implicated in the anti-inflammatory effects of low-dose radiation therapy. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Dose rate evaluation of workers on the operation floor in Fukushima-Daiichi Unit 3

    NASA Astrophysics Data System (ADS)

    Matsushita, Kaoru; Kurosawa, Masahiko; Shirai, Keisuke; Matsuoka, Ippei; Mukaida, Naoki

    2017-09-01

    At Fukushima Daiichi Nuclear Power Plant Unit 3, installation of a fuel handling machine is planned to support the removal of spent fuel. The dose rates at the workplace were calculated based on the source distribution measured using a collimator in order to confirm that the dose rates on the operation floor were within a manageable range. It was confirmed that the accuracy of the source distribution was C/M = 1.0-2.4. These dose rates were then used to plan the work on the operation floor.

  9. [Hand surgery in the German DRG System 2007].

    PubMed

    Franz, D; Windolf, J; Kaufmann, M; Siebert, C H; Roeder, N

    2007-05-01

    Hand surgery often needs only a short length of stay in hospital. Patients' comorbidity is low. Many hand surgery procedures do not need inpatient structures. Up until 2006 special procedures of hand surgery could not be coded. The DRG structure did not separate very complex and less complex operations. Specialized hospitals needed a proper case allocation of their patients within the G-DRG system. The DRG structure concerning hand surgery increased in version 2007 of the G-DRG system. The main parameter of DRG splitting is the complexity of the operation. Furthermore additional criteria such as more than one significant OR procedure, the patients' age, or special diagnoses influence case allocation. A special OPS code for complex cases treated with hand surgery was implemented. The changes in the DRG structure and the implementation of the new OPS code for complex cases establish a strong basis for the identification of different patient costs. Different case allocation leads to different economic impacts on departments of hand surgery. Whether the new OPS code becomes a DRG splitting parameter has to be calculated by the German DRG Institute for further DRG versions.

  10. A new approach to hand-based authentication

    NASA Astrophysics Data System (ADS)

    Amayeh, G.; Bebis, G.; Erol, A.; Nicolescu, M.

    2007-04-01

    Hand-based authentication is a key biometric technology with a wide range of potential applications both in industry and government. Traditionally, hand-based authentication is performed by extracting information from the whole hand. To account for hand and finger motion, guidance pegs are employed to fix the position and orientation of the hand. In this paper, we consider a component-based approach to hand-based verification. Our objective is to investigate the discrimination power of different parts of the hand in order to develop a simpler, faster, and possibly more accurate and robust verification system. Specifically, we propose a new approach which decomposes the hand in different regions, corresponding to the fingers and the back of the palm, and performs verification using information from certain parts of the hand only. Our approach operates on 2D images acquired by placing the hand on a flat lighting table. Using a part-based representation of the hand allows the system to compensate for hand and finger motion without using any guidance pegs. To decompose the hand in different regions, we use a robust methodology based on morphological operators which does not require detecting any landmark points on the hand. To capture the geometry of the back of the palm and the fingers in suffcient detail, we employ high-order Zernike moments which are computed using an effcient methodology. The proposed approach has been evaluated on a database of 100 subjects with 10 images per subject, illustrating promising performance. Comparisons with related approaches using the whole hand for verification illustrate the superiority of the proposed approach. Moreover, qualitative comparisons with state-of-the-art approaches indicate that the proposed approach has comparable or better performance.

  11. Posterior parietal cortex contains a command apparatus for hand movements.

    PubMed

    Rathelot, Jean-Alban; Dum, Richard P; Strick, Peter L

    2017-04-18

    Mountcastle and colleagues proposed that the posterior parietal cortex contains a "command apparatus" for the operation of the hand in immediate extrapersonal space [Mountcastle et al. (1975) J Neurophysiol 38(4):871-908]. Here we provide three lines of converging evidence that a lateral region within area 5 has corticospinal neurons that are directly linked to the control of hand movements. First, electrical stimulation in a lateral region of area 5 evokes finger and wrist movements. Second, corticospinal neurons in the same region of area 5 terminate at spinal locations that contain last-order interneurons that innervate hand motoneurons. Third, this lateral region of area 5 contains many neurons that make disynaptic connections with hand motoneurons. The disynaptic input to motoneurons from this portion of area 5 is as direct and prominent as that from any of the premotor areas in the frontal lobe. Thus, our results establish that a region within area 5 contains a motor area with corticospinal neurons that could function as a command apparatus for operation of the hand.

  12. Use of a microscope-mounted wide-angle point of view camera to record optimal hand position in ocular surgery.

    PubMed

    Gooi, Patrick; Ahmed, Yusuf; Ahmed, Iqbal Ike K

    2014-07-01

    We describe the use of a microscope-mounted wide-angle point-of-view camera to record optimal hand positions in ocular surgery. The camera is mounted close to the objective lens beneath the surgeon's oculars and faces the same direction as the surgeon, providing a surgeon's view. A wide-angle lens enables viewing of both hands simultaneously and does not require repositioning the camera during the case. Proper hand positioning and instrument placement through microincisions are critical for effective and atraumatic handling of tissue within the eye. Our technique has potential in the assessment and training of optimal hand position for surgeons performing intraocular surgery. It is an innovative way to routinely record instrument and operating hand positions in ophthalmic surgery and has minimal requirements in terms of cost, personnel, and operating-room space. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  13. Pre-operative combined 5-FU, low dose leucovorin, and sequential radiation therapy for unresectable rectal cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minsky, B.D.; Cohen, A.M.; Kemeny, N.

    1993-04-02

    The authors performed a Phase 1 trial to determine the maximum tolerated dose of combined pre-operative radiation (5040 cGy) and 2 cycles (bolus daily [times] 5) of 5-FU and low dose LV (20 mg/m2), followed by surgery and 10 cycles of post-operative LV/5-FU in patients with unresectable primary or recurrent rectal cancer. Twelve patients were entered. The initial dose of 5-FU was 325 mg/m2. 5-FU was to be escalated while the LV remained constant at 20 mg/m2. Chemotherapy began on day 1 and radiation on day 8. The post-operative chemotherapy was not dose escalated; 5-FU: 425 mg/m2 and LV: 20more » mg/m2. The median follow-up was 14 months (7--16 months). Following pre-operative therapy, the resectability rate with negative margins was 91% and the pathologic complete response rate was 9%. For the combined modality segment (preoperative) the incidence of any grade 3+ toxicity was diarrhea: 17%, dysuria: 8%, mucositis: 8%, and erythema: 8%. The median nadir counts were WBC: 3.1, HGB: 8.8, and PLT: 153000. The maximum tolerated dose of 5-FU for pre-operative combined LV/5-FU/RT was 325 mg/m2 with no escalation possible. Therefore, the recommended dose was less than 325 mg/m2. Since adequate doses of 5-FU to treat systemic disease could not be delivered until at least 3 months (cycle 3) following the start of therapy, the authors do not recommend that this 5-FU, low dose LV, and sequential radiation therapy regimen be used as presently designed. However, given the 91% resectability rate they remain encouraged with this approach. 31 refs., 1 fig., 2 tabs.« less

  14. Lifitegrast Ophthalmic

    MedlinePlus

    ... when you are finished. Do not save the liquid left in the container for your next dose.To instill the eye drops follow these steps: Wash your hands thoroughly with soap and water. Pull off one container of medication ...

  15. Shifting attention across near and far spaces: implications for the use of hands-free cell phones while driving.

    PubMed

    Ferlazzo, Fabio; Fagioli, Sabrina; Di Nocera, Francesco; Sdoia, Stefano

    2008-11-01

    In three experiments, participants performed two tasks concurrently during driving. In the peripheral detection task, they responded manually to visual stimuli delivered through a LED placed on the internal rear mirror; in the conversation task, they were engaged in a conversation with a passenger, or through earphone-operated, loudspeaker-operated, or hand-held cell phones. Results showed that drivers were slower at responding to the visual stimuli when conversing through a hand-held cell phone or an earphone-operated cell phone than when conversing through a loudspeaker-operated cell phone or with a passenger. These results suggest that due to the brain coding the space into multiple representations, devices that make phone conversations taking place in the near, personal space make drivers slower at responding to visual stimuli, compared to devices that make the conversation occurring in a far space.

  16. A hand-held apparatus for "nose-only" exposure of mice to inhalable microparticles as a dry powder inhalation targeting lung and airway macrophages.

    PubMed

    Kaur, Jatinder; Muttil, Pavan; Verma, Rahul Kumar; Kumar, Kaushlendra; Yadav, Awadh Bihari; Sharma, Rolee; Misra, Amit

    2008-05-10

    Microparticles containing isoniazid and rifabutin were aerosolised using a simple apparatus fabricated from a 15-ml centrifuge tube. The dose available for inhalation by rodents was determined by collecting microparticles emitted at the delivery port. The dose available for inhalation was proportional to durations of exposure ranging from 10 to 90 s (10.5-13.5 CV%) and the weight of powder taken for fluidization (10-50 mg, r2=0.982). The apparatus was then used to administer inhalations of microparticles to mice. Other groups of mice received free rifabutin orally, or by i.v. injection. Rifabutin was estimated in serum and tissues of dosed mice by HPLC. When approximately 20 mg of microparticles were loaded in the apparatus, approximately 2.5 mg were collected at the delivery port in 30 s of operation. Mice inhaled approximately 300 microg of the 2.5 mg emitted at the delivery port. Airway and lung macrophages of mice receiving inhalations for 30 s accumulated 0.38 microg of rifabutin, while the amount in blood serum of these mice was 0.62 microg. In mice receiving 83 microg rifabutin i.v. or orally, the intracellular amounts were 0.06 and 0.07 microg respectively, while the amounts in serum were 1.02 and 0.80 microg. These observations confirmed that inhalation of microparticles targeted airway and lung macrophages.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haseler, Luke J., E-mail: l.haseler@griffith.edu.au; Sibbitt, Randy R., E-mail: THESIBB2@aol.com; Sibbitt, Wilmer L., E-mail: wsibbitt@salud.unm.edu

    Purpose: Syringes are used for diagnostic fluid aspiration and fine-needle aspiration biopsy in interventional procedures. We determined the benefits, disadvantages, and patient safety implications of syringe and needle size on vacuum generation, hand force requirements, biopsy/fluid yield, and needle control during aspiration procedures. Materials and Methods: Different sizes (1, 3, 5, 10, and 20 ml) of the conventional syringe and aspirating mechanical safety syringe, the reciprocating procedure device, were studied. Twenty operators performed aspiration procedures with the following outcomes measured: (1) vacuum (torr), (2) time to vacuum (s), (3) hand force to generate vacuum (torr-cm{sup 2}), (4) operator difficulty duringmore » aspiration, (5) biopsy yield (mg), and (6) operator control of the needle tip position (mm). Results: Vacuum increased tissue biopsy yield at all needle diameters (P < 0.002). Twenty-milliliter syringes achieved a vacuum of -517 torr but required far more strength to aspirate, and resulted in significant loss of needle control (P < 0.002). The 10-ml syringe generated only 15% less vacuum (-435 torr) than the 20-ml device and required much less hand strength. The mechanical syringe generated identical vacuum at all syringe sizes with less hand force (P < 0.002) and provided significantly enhanced needle control (P < 0.002). Conclusions: To optimize patient safety and control of the needle, and to maximize fluid and tissue yield during aspiration procedures, a two-handed technique and the smallest syringe size adequate for the procedure should be used. If precise needle control or one-handed operation is required, a mechanical safety syringe should be considered.« less

  18. Ergonomic evaluation of a mechanical anastomotic stapler used by Japanese surgeons.

    PubMed

    Kono, Emiko; Tada, Mitsunori; Kouchi, Makiko; Endo, Yui; Tomizawa, Yasuko; Matsuo, Tomoko; Nomura, Sachiyo

    2014-06-01

    The satisfaction rating of currently available mechanical staplers for Japanese surgeons with small hands is low. To identify the issue, we examined the relationship of hand dimensions and grip force with the operation force of a mechanical circular stapler. Hand dimensions and grip force were measured in 113 Japanese surgeons (52 men and 61 women). We then evaluated the relationship between grip width and the operation force required to push the lever of the stapler, at three points on the lever, using a digital force gauge. The optimal grip width of the dominant hand was 62.5 ± 8.5 mm for men and 55.5 ± 5.9 mm for women (p < 0.001). The maximum grip force of the dominant hand was 44.2 ± 6.1 kg for men and 29.7 ± 4.5 kg for women (p < 0.001) and the maximum operation force required to push the lever 7.0, 45.0, and 73.0 mm from the end of the lever was 21.8, 28.6, and 42.4 kg, respectively. To our knowledge, this is the first ergonomic study of a surgical stapler to be conducted in Asia. Firing the stapler by gripping the proximal side of the lever is physically impossible for most Japanese women surgeons since the required operation force exceeds the maximum grip force, which probably accounts for the stress perceived by these women.

  19. Patient doses and occupational exposure in a hybrid operating room.

    PubMed

    Andrés, C; Pérez-García, H; Agulla, M; Torres, R; Miguel, D; Del Castillo, A; Flota, C M; Alonso, D; de Frutos, J; Vaquero, C

    2017-05-01

    This study aimed to characterize the radiation exposure to patients and workers in a new vascular hybrid operating room during X-ray-guided procedures. During one year, data from 260 interventions performed in a hybrid operating room equipped with a Siemens Artis Zeego angiography system were monitored. The patient doses were analysed using the following parameters: radiation time, kerma-area product, patient entrance reference point dose and peak skin dose. Staff radiation exposure and ambient dose equivalent were also measured using direct reading dosimeters and thermoluminescent dosimeters. The radiation time, kerma-area product, patient entrance reference point dose and peak skin dose were, on average, 19:15min, 67Gy·cm 2 , 0.41Gy and 0.23Gy, respectively. Although the contribution of the acquisition mode was smaller than 5% in terms of the radiation time, this mode accounted for more than 60% of the effective dose per patient. All of the worker dose measurements remained below the limits established by law. The working conditions in the hybrid operating room HOR are safe in terms of patient and staff radiation protection. Nevertheless, doses are highly dependent on the workload; thus, further research is necessary to evaluate any possible radiological deviation of the daily working conditions in the HOR. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Towards the definition of Institutional diagnostic reference levels in paediatric interventional cardiology procedures in Greece.

    PubMed

    Kottou, S; Kollaros, N; Plemmenos, C; Mastorakou, I; Apostolopoulou, S C; Tsapaki, V

    2018-02-01

    This study aimed to evaluate paediatric radiation doses in a dedicated cardiology hospital, with the objective of characterising patterns in dose variation. The ultimate purpose was to define Local (Institutional) Diagnostic Reference Levels (LDRLs) for different types of paediatric cardiac interventional procedures (IC), according to patient age. From a total of 710 cases performed during three consecutive years, by operators with more than 15 years of experience, the age was noted in only 477 IC procedures. The median values obtained for Fluoroscopy Time (FT), Number of Frames (N) and Kerma Area Product (P KA ) by age range were 5.8 min, 1322 and 2.0 Gy.cm 2 for <1 y; 6.5 min, 1403 and 3.0 Gy.cm 2 for 1 to <5 y; 5.9 min, 950 and 7.0 Gy.cm 2 for 5 to <10 y; 5.7 min, 940 and 14.0 Gy.cm 2 for 10 to <16 y, respectively. A large range of patient dose data is observed, depending greatly on procedure type and patient age. In all age groups the range of median FT, N and P KA values was 3.1-15.8 min, 579-1779 and 1.0-20.8 Gy.cm 2 respectively. Consequently, the definition of LDRLs presents challenges mainly due to the multiple clinical and technical factors affecting the outcome. On the other hand the lack of paediatric IC DRLs makes the identification of good practices more difficult. A consensus is needed on IC procedures nomenclature and grouping in order to allow a common assessment and comparison of doses. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Perioperative systemic steroid for rapid recovery in total knee and hip arthroplasty: a systematic review and meta-analysis of randomized trials.

    PubMed

    Yue, Chen; Wei, Rong; Liu, Youwen

    2017-06-27

    Perioperative systemic steroid administration for rapid recovery in total knee and hip arthroplasty (TKA/THA) is an important and controversial topic. We conducted this systematic review and meta-analysis to evaluate the overall benefits and harms of perioperative systemic steroid in patients undergoing TKA and THA. A comprehensive search was performed on PubMed, OVID, and Web of Science databases, and a systematic approach was carried out starting from the PRISMA recommendations. Relevant randomized controlled trials (RCTs) were selected. The risk of bias was evaluated according to the Cochrane Handbook for Systematic Reviews of Interventions version. Data were extracted and meta-analyzed or qualitatively synthesized for all the outcomes. Data were extracted from 11 trials involving 774 procedures. Meta-analysis showed that high-dose systemic steroid (dexamethasone > 0.1 mg/kg) rather than low dose is effective to reduce postoperative nausea and vomiting and postoperative acute pain (within 24 h). In addition, systemic steroid is associated within faster functional rehabilitation and greater inflammation control. On the other hand, systemic steroid is associated with a higher level of postoperative serum glucose on the operation day. The complications between groups are similarly low. Our study suggests that by providing lower incidence of postoperative nausea and vomiting and less postoperative acute pain, high-dose systemic steroid plays a critical role in rapid recovery to TKA and THA. The preliminary results also show the superior possibility of systemic steroid in functional rehabilitation and inflammation control. More large, high-quality studies that investigate the safety and dose-response relationship are necessary.

  2. The Effect of Alcohol-Based Hand Sanitizer Vapors on Evidential Breath Alcohol Test Results.

    PubMed

    Strawsine, Ellen; Lutmer, Brian

    2017-11-16

    This study was undertaken to determine if the application of alcohol-based hand sanitizers (ABHSs) to the hands of a breath test operator will affect the results obtained on evidential breath alcohol instruments (EBTs). This study obtained breath samples on three different EBTs immediately after application of either gel or foam ABHS to the operator's hands. A small, but significant, number of initial analyses (13 of 130, 10%) resulted in positive breath alcohol concentrations, while 41 samples (31.5%) resulted in a status code. These status codes were caused by ethanol vapors either in the room air or their inhalation by the subject, thereby causing a mouth alcohol effect. Replicate subject samples did not yield any consecutive positive numeric results. As ABHS application can cause a transitory mouth alcohol effect via inhalation of ABHS vapors, EBT operators should forego the use of ABHS in the 15 min preceding subject testing. © 2017 American Academy of Forensic Sciences.

  3. The effect of the involvement of the dominant or non-dominant hand on grip/pinch strengths and the Levine score in patients with carpal tunnel syndrome.

    PubMed

    Zyluk, A; Walaszek, I

    2012-06-01

    The Levine questionnaire is a disease-oriented instrument developed for outcome measurement of carpal tunnel syndrome (CTS) management. The objective of this study was to compare Levine scores in patients with unilateral CTS, involving the dominant or non-dominant hand, before and after carpal tunnel release. Records of 144 patients, 126 women (87%) and 18 men (13%) aged a mean of 58 years with unilateral CTS, treated operatively, were analysed. The dominant hand was involved in 100 patients (69%), the non-dominant in 44 (31%). The parameters were analysed pre-operatively, and at 1 and 6 months post-operatively. A comparison of Levine scores in patients with the involvement of the dominant or non-dominant hand showed no statistically significant differences at baseline and any of the follow-up measurements. Statistically significant differences were noted in total grip strength at baseline and at 6 month assessments and in key-pinch strength at 1 and 6 months.

  4. Tactile sensitivity of gloved hands in the cold operation.

    PubMed

    Geng, Q; Kuklane, K; Holmér, I

    1997-11-01

    In this study, tactile sensitivity of gloved hand in the cold operation has been investigated. The relations among physical properties of protective gloves and hand tactile sensitivity and cold protection were also analysed both objectively and subjectively. Subjects with various gloves participated in the experimental study during cold exposure at different ambient temperatures of -12 degrees C and -25 degrees C. Tactual performance was measured using an identification task with various sizes of objects over the percentage of misjudgment. Forearm, hand and finger skin temperatures were also recorded throughout. The experimental data were analysed using analysis of variance (ANOVA) model and the Tukey's multiple range test. The results obtained indicated that the tactual performance was affected both by gloves and by hands/fingers cooling. Effect of object size on the tactile discrimination was significant and the misjudgment increased when similar sizes of objects were identified, especially at -25 degrees C.

  5. Design of a terminal pointer hand controller for teleoperator applications

    NASA Technical Reports Server (NTRS)

    Saenger, E. L.; Woltosz, W. S.

    1973-01-01

    The design is described of a hand controller intended to achieve the highest possible compatibility with the hand of the human operator in a teleoperator system. Concepts drawings and model development are discussed along with the development of a prototype, and the mathematical control laws.

  6. Computer model to simulate ionizing radiation effects correlates with experimental data

    NASA Astrophysics Data System (ADS)

    Perez-Poch, Antoni

    Exposure to radiation from high energy protons and particles with ionizing properties is a major challenge for long-term space missions. The specific effect of such radiation on hematopoietic cells is still not fully understood. A number of experiments have been conducted on ground and in space. Those experiments on one hand, measure the extent of damage on blood markers. On the other hand, they intend to quantify the correlation between dose and energy from the radiation particles, with their ability to impair the hematopoietic stem and progenitor function. We present a computer model based on a neural network that intends to assess the relationship between dose, energy and number of hits on a particular cell, to the damage incurred to the human marrow cells. Calibration of the network is performed with the existing experimental data available in bibliography. Different sources of ionizing radiation at different doses (0-90 cGy) and along different patterns of a long-term exposure scenarios are simulated. Results are shown for a continuous variation of doses and are compared with specific data available in the literature. Some predictions are inferred for long-term scenarios of spaceflight, and the risk of jeopardizing a mission due to a major disfunction of the bone marrow is calculated. The method has proved successful in reproducing specific experimental data. We also discuss the significance and validity of the predicted ionizing radiation effects in situations such as long-term missions for a continuous range of dose.

  7. Linear modeling of human hand-arm dynamics relevant to right-angle torque tool interaction.

    PubMed

    Ay, Haluk; Sommerich, Carolyn M; Luscher, Anthony F

    2013-10-01

    A new protocol was evaluated for identification of stiffness, mass, and damping parameters employing a linear model for human hand-arm dynamics relevant to right-angle torque tool use. Powered torque tools are widely used to tighten fasteners in manufacturing industries. While these tools increase accuracy and efficiency of tightening processes, operators are repetitively exposed to impulsive forces, posing risk of upper extremity musculoskeletal injury. A novel testing apparatus was developed that closely mimics biomechanical exposure in torque tool operation. Forty experienced torque tool operators were tested with the apparatus to determine model parameters and validate the protocol for physical capacity assessment. A second-order hand-arm model with parameters extracted in the time domain met model accuracy criterion of 5% for time-to-peak displacement error in 93% of trials (vs. 75% for frequency domain). Average time-to-peak handle displacement and relative peak handle force errors were 0.69 ms and 0.21%, respectively. Model parameters were significantly affected by gender and working posture. Protocol and numerical calculation procedures provide an alternative method for assessing mechanical parameters relevant to right-angle torque tool use. The protocol more closely resembles tool use, and calculation procedures demonstrate better performance of parameter extraction using time domain system identification methods versus frequency domain. Potential future applications include parameter identification for in situ torque tool operation and equipment development for human hand-arm dynamics simulation under impulsive forces that could be used for assessing torque tools based on factors relevant to operator health (handle dynamics and hand-arm reaction force).

  8. Process for anodizing a robotic device

    DOEpatents

    Townsend, William T [Weston, MA

    2011-11-08

    A robotic device has a base and at least one finger having at least two links that are connected in series on rotary joints with at least two degrees of freedom. A brushless motor and an associated controller are located at each joint to produce a rotational movement of a link. Wires for electrical power and communication serially connect the controllers in a distributed control network. A network operating controller coordinates the operation of the network, including power distribution. At least one, but more typically two to five, wires interconnect all the controllers through one or more joints. Motor sensors and external world sensors monitor operating parameters of the robotic hand. The electrical signal output of the sensors can be input anywhere on the distributed control network. V-grooves on the robotic hand locate objects precisely and assist in gripping. The hand is sealed, immersible and has electrical connections through the rotary joints for anodizing in a single dunk without masking. In various forms, this intelligent, self-contained, dexterous hand, or combinations of such hands, can perform a wide variety of object gripping and manipulating tasks, as well as locomotion and combinations of locomotion and gripping.

  9. Acute Radiation Risk and BRYNTRN Organ Dose Projection Graphical User Interface

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.; Hu, Shaowen; Nounu, Hateni N.; Kim, Myung-Hee

    2011-01-01

    The integration of human space applications risk projection models of organ dose and acute radiation risk has been a key problem. NASA has developed an organ dose projection model using the BRYNTRN with SUM DOSE computer codes, and a probabilistic model of Acute Radiation Risk (ARR). The codes BRYNTRN and SUM DOSE are a Baryon transport code and an output data processing code, respectively. The risk projection models of organ doses and ARR take the output from BRYNTRN as an input to their calculations. With a graphical user interface (GUI) to handle input and output for BRYNTRN, the response models can be connected easily and correctly to BRYNTRN. A GUI for the ARR and BRYNTRN Organ Dose (ARRBOD) projection code provides seamless integration of input and output manipulations, which are required for operations of the ARRBOD modules. The ARRBOD GUI is intended for mission planners, radiation shield designers, space operations in the mission operations directorate (MOD), and space biophysics researchers. BRYNTRN code operation requires extensive input preparation. Only a graphical user interface (GUI) can handle input and output for BRYNTRN to the response models easily and correctly. The purpose of the GUI development for ARRBOD is to provide seamless integration of input and output manipulations for the operations of projection modules (BRYNTRN, SLMDOSE, and the ARR probabilistic response model) in assessing the acute risk and the organ doses of significant Solar Particle Events (SPEs). The assessment of astronauts radiation risk from SPE is in support of mission design and operational planning to manage radiation risks in future space missions. The ARRBOD GUI can identify the proper shielding solutions using the gender-specific organ dose assessments in order to avoid ARR symptoms, and to stay within the current NASA short-term dose limits. The quantified evaluation of ARR severities based on any given shielding configuration and a specified EVA or other mission scenario can be made to guide alternative solutions for attaining determined objectives set by mission planners. The ARRBOD GUI estimates the whole-body effective dose, organ doses, and acute radiation sickness symptoms for astronauts, by which operational strategies and capabilities can be made for the protection of astronauts from SPEs in the planning of future lunar surface scenarios, exploration of near-Earth objects, and missions to Mars.

  10. Intermittent Drug Dosing Intervals Guided by the Operational Multiple Dosing Half Lives for Predictable Plasma Accumulation and Fluctuation

    PubMed Central

    Grover, Anita; Benet, Leslie Z.

    2013-01-01

    Intermittent drug dosing intervals are usually initially guided by the terminal pharmacokinetic half life and are dependent on drug formulation. For chronic multiple dosing and for extended release dosage forms, the terminal half life often does not predict the plasma drug accumulation or fluctuation observed. We define and advance applications for the operational multiple dosing half lives for drug accumulation and fluctuation after multiple oral dosing at steady-state. Using Monte Carlo simulation, our results predict a way to maximize the operational multiple dosing half lives relative to the terminal half life by using a first-order absorption rate constant close to the terminal elimination rate constant in the design of extended release dosage forms. In this way, drugs that may be eliminated early in the development pipeline due to a relatively short half life can be formulated to be dosed at intervals three times the terminal half life, maximizing compliance, while maintaining tight plasma concentration accumulation and fluctuation ranges. We also present situations in which the operational multiple dosing half lives will be especially relevant in the determination of dosing intervals, including for drugs that follow a direct PKPD model and have a narrow therapeutic index, as the rate of concentration decrease after chronic multiple dosing (that is not the terminal half life) can be determined via simulation. These principles are illustrated with case studies on valproic acid, diazepam, and anti-hypertensives. PMID:21499748

  11. Using Goal Setting, Task Clarification, and Feedback to Increase the Use of the Hands-Free Technique by Hospital Operating Room Staff

    ERIC Educational Resources Information Center

    Cunningham, Thomas R.; Austin, John

    2007-01-01

    We evaluated the effects of a behavioral treatment on the safe passing of sharp instruments using the hands-free technique among hospital operating room personnel during surgical procedures. Treatment consisted of participative goal setting, task clarification, and feedback. The average percentage of sharp instruments passed safely increased from…

  12. A single-dose regimen for antimicrobial prophylaxis to prevent perioperative infection in urological clean and clean-contaminated surgery.

    PubMed

    Higuchi, Yoshihide; Takesue, Yoshio; Yamada, Yusuke; Ueda, Yasuo; Suzuki, Toru; Aihara, Kinue; Maruyama, Takuo; Kondoh, Nobuyuki; Nojima, Michio; Yamamoto, Shingo

    2011-04-01

    A single dose of antimicrobial prophylaxis (AMP) was administered parenterally for the prevention of perioperative infection in a total of 788 patients undergoing urological surgery, including 380 endoscopic-instrumental, 328 clean, and 80 clean-contaminated operations performed at our institute between January 2007 and December 2009. Surgical site infections (SSIs), urinary tract infections (UTIs), and remote infections (RIs) were prospectively surveyed. The definition for a single dose of AMP allowed for the administration of an additional dose of an antimicrobial during surgery if the procedure was longer than 3 h, but not for the parenteral or oral administration at the end of the procedure in the recovery room, or at a later time over a period of more than 24 h. UTI was observed in 12 (3.2%) patients after endoscopic-instrumental operation, 1 (0.3%) after clean operation, and 1 (0.9%) after clean-contaminated operation. SSI was observed in 2 (0.6%) patients after clean operation but in none after clean-contaminated operations. RI was observed in 1 (0.3%) patient after endoscopic-instrumental operation, 3 (0.9%) after clean operation, and none after clean-contaminated operations. A single-dose regimen of AMP was effective and feasible for the prevention of perioperative infections, including SSIs, UTIs, and RIs, in endoscopic-instrumental, clean, and clean-contaminated urological surgical procedures.

  13. Frequency of Hand Decontamination of Intraoperative Providers and Reduction of Postoperative Healthcare-Associated Infections: A Randomized Clinical Trial of a Novel Hand Hygiene System.

    PubMed

    Koff, Matthew D; Brown, Jeremiah R; Marshall, Emily J; O'Malley, A James; Jensen, Jens T; Heard, Stephen O; Longtine, Karen; O'Neill, Melissa; Longtine, Jaclyn; Houston, Donna; Robison, Cindy; Moulton, Eric; Patel, Hetal M; Loftus, Randy W

    2016-08-01

    BACKGROUND Healthcare provider hands are an important source of intraoperative bacterial transmission events associated with postoperative infection development. OBJECTIVE To explore the efficacy of a novel hand hygiene improvement system leveraging provider proximity and individual and group performance feedback in reducing 30-day postoperative healthcare-associated infections via increased provider hourly hand decontamination events. DESIGN Randomized, prospective study. SETTING Dartmouth-Hitchcock Medical Center in New Hampshire and UMass Memorial Medical Center in Massachusetts. PATIENTS Patients undergoing surgery. METHODS Operating room environments were randomly assigned to usual intraoperative hand hygiene or to a personalized, body-worn hand hygiene system. Anesthesia and circulating nurse provider hourly hand decontamination events were continuously monitored and reported. All patients were followed prospectively for the development of 30-day postoperative healthcare-associated infections. RESULTS A total of 3,256 operating room environments and patients (1,620 control and 1,636 treatment) were enrolled. The mean (SD) provider hand decontamination event rate achieved was 4.3 (2.9) events per hour, an approximate 8-fold increase in hand decontamination events above that of conventional wall-mounted devices (0.57 events/hour); P<.001. Use of the hand hygiene system was not associated with a reduction in healthcare-associated infections (odds ratio, 1.07 [95% CI, 0.82-1.40], P=.626). CONCLUSIONS The hand hygiene system evaluated in this study increased the frequency of hand decontamination events without reducing 30-day postoperative healthcare-associated infections. Future work is indicated to optimize the efficacy of this hand hygiene improvement strategy. Infect Control Hosp Epidemiol 2016;37:888-895.

  14. Mobile Phone Use Behaviors and Postures on Public Transportation Systems.

    PubMed

    Liang, Huey-Wen; Hwang, Yaw-Huei

    2016-01-01

    Mobile phones are common in our daily life, but the users' preferences for postures or screen operating styles have not been studied. This was a cross-sectional and observational study. We randomly sampled passengers who used mobile phones on the Mass Rapid Transit (MRT) system in metropolitan Taipei. A checklist was used to observe their body postures and screen operating styles while sitting or standing. As a result, 1,230 subjects from 400 trips were observed. Overall, of all the passengers who were sitting, 41% of them were using mobile phones. The majority of the tasks involved browsing (84%) with their phones in a portrait orientation (93%). Different-hand holding/operating was the most commonly used operating style while sitting (46%) and same-hand holding/operating was the most common while standing (46%). The distribution of screen operating styles was significantly different for those sitting than for those standing and for different genders and age groups. The most frequently observed postures while sitting were having one's trunk against a backrest, feet on the floor and with or without an arm supported (58%). As for the users who were standing, the both- and different-hands groups had a high proportion of arms unsupported, feet on the floor and either their trunk supported or not. In contrast, the same-hand group tended to have their trunk unsupported, were holding a pole or handstrap and had both feet on floor. Further studies are warranted to characterize the ergonomic exposure of these commonly used postures and operating styles, and our results will help guide the selection of experimental conditions for laboratory settings.

  15. Multiple sensor smart robot hand with force control

    NASA Technical Reports Server (NTRS)

    Killion, Richard R.; Robinson, Lee R.; Bejczy, Antal

    1987-01-01

    A smart robot hand developed at JPL for the Protoflight Manipulator Arm (PFMA) is described. The development of this smart hand was based on an integrated design and subsystem architecture by considering mechanism, electronics, sensing, control, display, and operator interface in an integrated design approach. The mechanical details of this smart hand and the overall subsystem are described elsewhere. The sensing and electronics components of the JPL/PFMA smart hand are summarized and it is described in some detail in control capabilities.

  16. Anthropomorphic Robot Hand And Teaching Glove

    NASA Technical Reports Server (NTRS)

    Engler, Charles D., Jr.

    1991-01-01

    Robotic forearm-and-hand assembly manipulates objects by performing wrist and hand motions with nearly human grasping ability and dexterity. Imitates hand motions of human operator who controls robot in real time by programming via exoskeletal "teaching glove". Telemanipulator systems based on this robotic-hand concept useful where humanlike dexterity required. Underwater, high-radiation, vacuum, hot, cold, toxic, or inhospitable environments potential application sites. Particularly suited to assisting astronauts on space station in safely executing unexpected tasks requiring greater dexterity than standard gripper.

  17. Evaluation of the kinesthetic sense and function of the hand in early period in operated cervical disc hernia.

    PubMed

    Kara, Býlge; Yildirim, Yücel; Karadýbak, Dýdem; Acar, Umýt

    2006-06-01

    A prospective study made into cervical disc hernias. To determine the kinesthetic sense and hand functions, which are important for the patients with cervical disc hernia to return to work life and daily activities that need skill. Neurosurgical department. Data Symptoms in cervical disc hernias and hand functions are affected depending on long-term pain. The evaluation of the hand is essential in assessing the patients' overall recovery and ability to return to daily activities and work life. Thirty-four patients with cervical disc hernia, who were operated on, were included in the study. Eight different test positions in the assessment of the hand's kinesthetic sense and hand function sort (HFS) in the evaluation of the hand function were applied. The disability levels of the patients were determined with The Neck Pain and Disability Scale, on the preoperative and postoperative discharge day and in the postoperative second month. Patients were divided into groups according to the side involved. In the evaluation of the kinesthetic test of the hand, only in the postoperative second month was a significant difference observed between the 1, 2, 3, and 4 test positions of the right side of the groups. On the other hand, no significant difference was found between the groups in the assessment of the hand function. In the measurement of hand functions and disability levels, strong and important correlations were determined. An early assessment of the hand's kinesthetic sense and function is instrumental in the patients' evaluation of recovery and resumption of work.

  18. The apparent mass and mechanical impedance of the hand and the transmission of vibration to the fingers, hand, and arm

    NASA Astrophysics Data System (ADS)

    Concettoni, Enrico; Griffin, Michael

    2009-08-01

    Although hand-transmitted vibration causes injury and disease, most often evident in the fingers, the biodynamic responses of the fingers, hand, and arm are not yet well understood. A method of investigating the motion of the entire finger-hand-arm system, based on the simultaneous measurement of the biodynamic response at the driving point and the transmissibility to many points on the finger-hand-arm system, is illustrated. Fourteen male subjects participated in an experiment in which they pushed down on a vertically vibrating metal plate with their right forearm pronated and their elbow bent at 90°. The apparent mass and mechanical impedance of the finger-hand-arm system were measured for each of seven different contact conditions between the plate and the fingers and hand. Simultaneously, the vibration of the fingers, hand, and arm was measured at 41 locations using a scanning laser Doppler vibrometer. Transmissibilities showed how the vibration was transmitted along the arm and allowed the construction of spectral operating deflection shapes showing the vibration pattern of the fingers, hand, and arm for each of the seven contact conditions. The vibration patterns at critical frequencies for each contact condition have been used to explain features in the driving point biodynamic responses and the vibration behaviour of the hand-arm system. Spectral operating deflection shapes for the upper limb assist the interpretation of driving point biodynamic responses and help to advance understanding required to predict, explain, and control the various effects of hand-transmitted vibration.

  19. Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures

    PubMed Central

    Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel

    2016-01-01

    Aims This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. Methods and results From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose–area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). Conclusion The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. PMID:26589627

  20. 75 FR 11435 - Airworthiness Directives; Airbus Model A300 B4-2C, B4-103, and B4-203 Airplanes; and Model A300...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ... operator reported that, during a routine inspection, the Right Hand frame 40 forward fitting between... result in a deterioration of the structural integrity of the frame. * * * * * We are issuing this AD to... operator reported that, during a routine inspection, the Right Hand frame 40 forward fitting between...

  1. Three-Hand Endoscopic Endonasal Transsphenoidal Surgery: Experience With an Anatomy-Preserving Mononostril Approach Technique.

    PubMed

    Eseonu, Chikezie I; ReFaey, Karim; Pamias-Portalatin, Eva; Asensio, Javier; Garcia, Oscar; Boahene, Kofi D; Quiñones-Hinojosa, Alfredo

    2018-02-01

    Variations on the endoscopic transsphenoidal approach present unique surgical techniques that have unique effects on surgical outcomes, extent of resection (EOR), and anatomical complications. To analyze the learning curve and perioperative outcomes of the 3-hand endoscopic endonasal mononostril transsphenoidal technique. Prospective case series and retrospective data analysis of patients who were treated with the 3-hand transsphenoidal technique between January 2007 and May 2015 by a single neurosurgeon. Patient characteristics, preoperative presentation, tumor characteristics, operative times, learning curve, and postoperative outcomes were analyzed. Volumetric EOR was evaluated, and a logistic regression analysis was used to assess predictors of EOR. Two hundred seventy-five patients underwent an endoscopic transsphenoidal surgery using the 3-hand technique. One hundred eighteen patients in the early group had surgery between 2007 and 2010, while 157 patients in the late group had surgery between 2011 and 2015. Operative time was significantly shorter in the late group (161.6 min) compared to the early group (211.3 min, P = .001). Both cohorts had similar EOR (early group 84.6% vs late group 85.5%, P = .846) and postoperative outcomes. The learning curve showed that it took 54 cases to achieve operative proficiency with the 3-handed technique. Multivariate modeling suggested that prior resections and preoperative tumor size are important predictors for EOR. We describe a 3-hand, mononostril endoscopic transsphenoidal technique performed by a single neurosurgeon that has minimal anatomic distortion and postoperative complications. During the learning curve of this technique, operative time can significantly decrease, while EOR, postoperative outcomes, and complications are not jeopardized. Copyright © 2017 by the Congress of Neurological Surgeons

  2. Exposure of the examiner to radiation during myelography versus radiculography and root block: A comparative study.

    PubMed

    Yamane, Kentaro; Kai, Nobuo; Miyamoto, Tadashi; Matsushita, Tomohiro

    2017-03-01

    Exposure to radiation over many years prompts concerns regarding potential health-related effects, particularly the incidence of cataracts and the development of cancer. The purpose of this study was to examine and compare the exposure of the examiner to radiation during myelography versus radiculography and root block. A total of 114 examinations were performed in our institute in the 6 months. Sixty-two examinations were performed during myelography in the first 3 months (MG group), while 52 were performed during radiculography and root block in the last 3 months (RB group). The examiner wore a torso protector, a neck protector, radiation protection gloves, and radiation protection glasses. Optically stimulated luminescence (OSL) dosimeter badges were placed on both the inside and the outside of each protector. The dosimeters were exchanged every month. Radiation doses (mSv) were measured as the integrated radiation quantity every month from the OSL dosimeters. The effective dose and the equivalent doses of hand, skin, and eyes were investigated. The mean equivalent doses were significantly lower outside the neck, torso, eye protectors, and inside the torso protector in the RB group than in the MG group. Conversely, the mean equivalent dose was significantly lower outside the hand protector in the MG group than in the RB group. The use of a neck protector significantly decreased the effective dose compared to the non-use of a neck protector in the RB group. The present study showed the standard radiation exposure to the examiner during myelography, radiculography, and root block. Receiving full protection including a neck protector and protection gloves is an easy and reliable means to reduce radiation exposure. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  3. [Antibacterial prevention of suppurative complications after operations on the large intestine].

    PubMed

    Kuzin, M I; Pomelov, V S; Vandiaev, G K; Ialgashev, T Ia; Blatun, L A

    1983-05-01

    The data on comparative study of complications after operations on the large intestine are presented. During the preoperative period, 62 patients of the control group were treated with phthalylsulfathiazole, nevigramon and nystatin. Thirty-nine patients of the test group were treated with metronidazole and kanamycin monosulfate. Kanamycin monosulfate was used 3 days before the operation in a dose of 0.5 g orally 4 times a day whereas metronidazole in a dose of 0.5 g 3 times a day. The last doses of the drugs were administered 4-5 hours before the operation. After the operations the patients were treated with kanamycin sulfate for 3-5 days in a daily dose of 2 g intramuscularly. The number of the postoperative suppurative complications decreased from 22 to 5 per cent. No lethal outcomes were registered in the test group. The number of lethal outcomes in the control group amounted to 8 per cent.

  4. A three-finger multisensory hand for dexterous space robotic tasks

    NASA Technical Reports Server (NTRS)

    Murase, Yuichi; Komada, Satoru; Uchiyama, Takashi; Machida, Kazuo; Akita, Kenzo

    1994-01-01

    The National Space Development Agency of Japan will launch ETS-7 in 1997, as a test bed for next generation space technology of RV&D and space robot. MITI has been developing a three-finger multisensory hand for complex space robotic tasks. The hand can be operated under remote control or autonomously. This paper describes the design and development of the hand and the performance of a breadboard model.

  5. Effect of dose and size on defect engineering in carbon cluster implanted silicon wafers

    NASA Astrophysics Data System (ADS)

    Okuyama, Ryosuke; Masada, Ayumi; Shigematsu, Satoshi; Kadono, Takeshi; Hirose, Ryo; Koga, Yoshihiro; Okuda, Hidehiko; Kurita, Kazunari

    2018-01-01

    Carbon-cluster-ion-implanted defects were investigated by high-resolution cross-sectional transmission electron microscopy toward achieving high-performance CMOS image sensors. We revealed that implantation damage formation in the silicon wafer bulk significantly differs between carbon-cluster and monomer ions after implantation. After epitaxial growth, small and large defects were observed in the implanted region of carbon clusters. The electron diffraction pattern of both small and large defects exhibits that from bulk crystalline silicon in the implanted region. On the one hand, we assumed that the silicon carbide structure was not formed in the implanted region, and small defects formed because of the complex of carbon and interstitial silicon. On the other hand, large defects were hypothesized to originate from the recrystallization of the amorphous layer formed by high-dose carbon-cluster implantation. These defects are considered to contribute to the powerful gettering capability required for high-performance CMOS image sensors.

  6. Effect of Cellular Mobile Phone Use and Cetrizine on Hand-Eye Coordination and Visual Acuity.

    PubMed

    Gawit, Kalpita Ganpat; Tiwari, Smita Anand; Kasabe, Gauri Hari; Deshpande, Pradeep Kisanrao; Ghongane, Balasaheb Baburao

    2017-09-01

    Cellular mobile phones are a major cause of distraction especially while driving. The aggressive and inappropriate use of cellular mobile phones has increased the risk of accidents. Similar alerts are available in literature for certain substances and drugs (e.g. second generation anti H1 drug -Cetirizine) which also derange psychomotor performance and parameters of alertness. This study measured variations in hand-eye coordination and visual acuity due to use of cellular mobile phone in comparison to that of commonly used antihistaminic drug viz., single dose Cetirizine 10 mg. It was a single blind, single dose, interventional study, 100 healthy human volunteers divided into two groups. Baseline readings of all volunteers were noted. Group-I (n=50) was Cetirizine group (10mg orally stat), Group -II (n=50) Cellular mobile phone user group. Alertness was tested on hand- steadiness tester (Reaction Time Index = RTI) and on Flicker-fusion apparatus (visual acuity - Critical Flicker Fusion Frequency per second= CFFF/sec). Baseline readings of all volunteers were noted before intervention. Baseline was compared with readings at three hour post-intervention and was analysed by paired t-test. Inter-group comparison of parameters was also done and was analysed by unpaired t-test. The baseline RTI (95.46±41.74, 85.11±39.05) and CFF low and high (40.07±9.970, 40.76±9.309 and 40.42±9.035, 40.48±9.863) respectively, in Cetirizine group and Mobile user group were comparable. The RTI increased significantly (116.4±51.46, 102.8±49.26) in both the groups after intervention. However, there is no significant change in CFF intensity from baseline in either group post-intervention. Concurrent use of mobile phone while performing tasks, showed significant impairment of hand-steadiness which was comparable to that produced by single dose Cetirizine 10 mg and this may be one of the factors contributing to their close association with road traffic accidents.

  7. [RS3PE-syndrome].

    PubMed

    Segerer, S; Dietz-Laukemann, P; Schattenkirchner, M

    1999-02-01

    The RS3PE syndrome (Remitting Seronegative Symmetrical Synovitis with Pitting Edema) is a manifestation of rheumatoid arthritis in the elderly with a good prognosis. It usually presents as an acute, symmetric polysynovitis with edema of the dorsum of the hands and feet. Anti-inflammatory treatment with corticosteroids leads to prompt improvement. We describe the case of an 81 year old man with a primarily unilateral manifestation involving the right hand. A thrombosis of the axillary vein was suspected. Within a few days he developed a pitting edema of the dorsum of the other hand. Movement of both shoulders and wrists was painful. Low-dose corticosteroid therapy resulted in a rapid improvement of the edema and the inflammatory symptoms.

  8. Hand-arm vibration syndrome and dose-response relation for vibration induced white finger among quarry drillers and stonecarvers. Italian Study Group on Physical Hazards in the Stone Industry.

    PubMed Central

    Bovenzi, M

    1994-01-01

    OBJECTIVES--To investigate the occurrence of disorders associated with the hand arm vibration syndrome in a large population of stone workers in Italy. The dose-response relation for vibration induced white finger (VWF) was also studied. METHODS--The study population consisted of 570 quarry drillers and stonecarvers exposed to vibration and 258 control stone workers who performed only manual activity. Each subject was interviewed with health and workplace assessment questionnaires. Sensorineural and VWF disorders were staged according to the Stockholm workshop scales. Vibration was measured on a representative sample of percussive and rotary tools. The 8 h energy equivalent frequency weighted acceleration (A (8)) and lifetime vibration doses were calculated for each of the exposed stone workers. RESULTS--Sensorineural and musculoskeletal symptoms occurred more frequently in the workers exposed to vibration than in the controls, but trend statistics did not show a linear exposure-response relation for these disorders. The prevalence of VWF was found to be 30.2% in the entire group exposed to vibration. Raynaud's phenomenon was discovered in 4.3% of the controls. VWF was strongly associated with exposure to vibration and a monotonic dose-response relation was found. According to the exposure data of this study, the expected percentage of stone workers affected with VWF tends to increase roughly in proportion to the square root of A(8) (for a particular exposure period) or in proportion to the square root of the duration of exposure (for a constant magnitude of vibration). CONCLUSION--Even although limited to a specific work situation, the dose-response relation for VWF estimated in this study suggests a time dependency such that halving the years of exposure allows a doubling of the energy equivalent vibration. According to these findings, the vibration exposure levels currently under discussion within the European Community seem to represent reasonable exposure limits for the protection of workers against the harmful effects of hand transmitted vibration. PMID:7951792

  9. [Evaluation of a waterless, scrubless chlorhexidine gluconate/ethanol surgical scrub and povidone-iodine for antimicrobial efficacy].

    PubMed

    Choi, Jeong Sil

    2008-02-01

    The purpose of this study was to compare 1% chlorhexidine-gluconate/61% ethanol (CHG/Ethanol) emollient and 7.5% povidone-iodine (PVI) scrub for antimicrobial,residual effect, and skin condition. CHG/Ethanol emollient hand hygiene was performed waterless, and brushless by operating doctors and nurses (N=20). PVI hand washing was performed with water and a brush (N=20) for 5 min. The subjects were asked to press their left hand in hand-shaped agar before a surgical scrub, immediately after a surgical scrub and after the operation. The amount of isolated microorganisms were calculated by counting the number of divided areas(1 x 1 cm, 160 cell) which were culture positive in the hand culture plate. The skin condition was evaluated. The antimicrobial count of CHG/Ethanol emollient and PVI immediately post surgical scrub was 0.0 vs. 4.1 (p>.05), and after the operation was 0.1 vs. 37.8 (p>.05)respectively. The Residual effect of CHG/Ethanol emollient immediately post surgical scrub and after the operation were 0.0 vs. 0.1 (p>.05), and PVI were 4.1 vs. 37.8 (p>.05)respectively. The skin condition and satisfaction of CHG/Ethanol emollient was higher than PVI (p<.05). The antimicrobial effect between CHG/Ethanol emollient and PVI were the same. Considering skin condition, satisfaction and allergic reaction CHG/Ethanol emollient for surgical scrub is recommended in Korea.

  10. Financial impact of hand surgery programs on academic medical centers.

    PubMed

    Hasan, Jafar S; Chung, Kevin C; Storey, Amy F; Bolg, Mary L; Taheri, Paul A

    2007-02-01

    This study analyzes the financial performance of hand surgery in the Department of Surgery at the University of Michigan. This analysis can serve as a reference for other medical centers in the financial evaluation of a hand surgery program. Fiscal year 2004 billing records for all patients (n = 671) who underwent hand surgery procedures were examined. The financial data were separated into professional revenues and costs (relating to the hand surgery program in the Section of Plastic Surgery) and into facility revenues and costs (relating to the overall University of Michigan Health System). Professional net revenue was calculated by applying historical collection rates to procedural and clinic charges. Facility revenue was calculated by applying historical collection rates to the following charge categories: inpatient/operating room, clinic facility, neurology/electromyography, radiology facilities, and occupational therapy. Total professional costs were calculated by adding direct costs and allocated overhead costs. Facility costs were obtained from the hospital's cost accounting system. Professional and facility incomes were calculated by subtracting costs from revenues. The net professional revenue and total costs were 1,069,836 and 1,027,421 dollars, respectively. Professional operating income was 42,415 dollars, or 3.96 percent of net professional revenue. Net facility revenue and total costs were 5,500,606 and 4,592,534 dollars, respectively. Facility operating income was 908,071 dollars, or 16.51 percent of net facility revenues. While contributing to the academic mission of the institution, hand surgery is financially rewarding for the Department of Surgery. In addition, hand surgery activity contributes substantially to the financial well-being of the academic medical center.

  11. Improving the performance of membrane bioreactors by powdered activated carbon dosing with cost considerations.

    PubMed

    Yang, W; Paetkau, M; Cicek, N

    2010-01-01

    Effects of powdered activated carbon (PAC) dosing on the overall performance of membrane bioreactors (MBR) were investigated in two bench-scale submerged MBRs. Positive impacts of PAC dosing on membrane fouling and the removal of 17beta-estradiol (E2) and 17alpha-ethyinylestradiol (EE2) were demonstrated over a six-month stable operational period. PAC dosing in the MBR increased the removal rates of E2 and EE2 by 3.4% and 15.8%, respectively. The average soluble extracellular polymeric substances (EPS) and colloidal total organic carbon (TOC) concentrations in the PAC-MBR sludge was 60.1% and 61.8% lower than the control MBR sludge, respectively. Lower soluble EPS and colloidal TOC concentrations in the PAC-MBR sludge resulted in a slower rate of trans-membrane pressure (TMP) increase during MBRs operation, which could prolong the lifespan of membranes. Cost assessment showed that PAC dosing could reduce the operating cost for membrane cleaning and/or membrane replacement by about 25%. The operating cost for PAC dosing could be offset by the benefit from its reducing the cost for membrane maintenance.

  12. Isothermal crystallization of gamma irradiated LDPE in the presence of oxygen

    NASA Astrophysics Data System (ADS)

    Lanfranconi, M. R.; Alvarez, V. A.; Perez, C. J.

    2015-06-01

    This work is focused on the study of the effect of oxygen on the isothermal crystallization process of gamma irradiated low density polyethylene (LDPE). The induction time increased with the dose indicating a retarding effect. On other hand, at the same dose, this parameter decreased with the augment in the oxygen content. The classical Avrami equation was used to analyze the crystallization kinetic of these materials. n values suggested that both, the dose and the oxygen content, did not affect the mechanism of crystals growth. An Arrhenius type equation was used for the rate constant (k). Used models correctly reproduced the experimental data. TTT diagrams of studied materials were constructed and also reflected the effects of the doses and the oxygen content.

  13. A PC-based software test for measuring alcohol and drug effects in human subjects.

    PubMed

    Mills, K C; Parkman, K M; Spruill, S E

    1996-12-01

    A new software-based visual search and divided-attention test of cognitive performance was developed and evaluated in an alcohol dose-response study with 24 human subjects aged 21-62 years. The test used language-free, color, graphic displays to represent the visuospatial demands of driving. Cognitive demands were increased over previous hardware-based tests, and the motor skills required for the test involved minimal eye movements and eye-hand coordination. Repeated performance on the test was evaluated with a latin-square design by using a placebo and two alcohol doses, low (0.48 g/kg/LBM) and moderate (0.72 g/kg/LBM). The data on 7 females and 17 males yielded significant falling and rising impairment effects coincident with moderate rising and falling breath alcohol levels (mean peak BrALs = 0.045 g/dl and 0.079 g/dl). None of the subjects reported eye-strain or psychomotor fatigue as compared with previous tests. The high sensitivity/variance relative to use in basic and applied research, and worksite fitness-for-duty testing, was discussed. The most distinct advantage of a software-based test that operates on readily available PCs is that it can be widely distributed to researchers with a common reference to compare a variety of alcohol and drug effects.

  14. A new scheme of force reflecting control

    NASA Technical Reports Server (NTRS)

    Kim, Won S.

    1992-01-01

    A new scheme of force reflecting control has been developed that incorporates position-error-based force reflection and robot compliance control. The operator is provided with a kinesthetic force feedback which is proportional to the position error between the operator-commanded and the actual position of the robot arm. Robot compliance control, which increases the effective compliance of the robot, is implemented by low pass filtering the outputs of the force/torque sensor mounted on the base of robot hand and using these signals to alter the operator's position command. This position-error-based force reflection scheme combined with shared compliance control has been implemented successfully to the Advanced Teleoperation system consisting of dissimilar master-slave arms. Stability measurements have demonstrated unprecedentedly high force reflection gains of up to 2 or 3, even though the slave arm is much stiffer than operator's hand holding the force reflecting hand controller. Peg-in-hole experiments were performed with eight different operating modes to evaluate the new force-reflecting control scheme. Best task performance resulted with this new control scheme.

  15. [Clinical application of biofragmentable anastomosis ring for intestinal anastomosis].

    PubMed

    Ye, Feng; Lin, Jian-jiang

    2006-11-01

    To compare the efficacy of the biofragmentable anastomotic ring (BAR) with conventional hand-sutured and stapling techniques,and to evaluate the safety and applicability of the BAR in intestinal anastomosis. The totol of 498 patients performed intestinal anastomosis from January 2000 to November 2005 were allocated to BAR group (n=186), hand-sutured group (n=177) and linear cutter group (n=135). The operative time, postoperative convalescence and corresponding complication were recorded. Postoperative anastomotic inflammation and anastomotic stenosis were observed during half or one year follow-up of 436 patients. The operative time was (102 +/- 16) min in the BAR group, (121 +/- 15) min in the hand-sutured group, and (105 +/- 18 ) min in the linear cutter group. The difference was significant statistically (P <0.05). The operative time in BAR group and linear cutter group was shorter than hand-sutured group. One case of anastomotic leakage was noted in the BAR group, one case in the hand-sutured group, and none in the linear cutter group. They were cured by conservative methods. One case of anastomotic obstruction happened in the BAR group, one case in the hand-sutured group. Two of them were cured by conservative methods. Two cases of anastomotic obstruction happened in the hand-sutured group. However, one of them required reoperation to remove the obstruction. In the BAR, hand-sutured and the linear cutter group, the postoperative first flatus time was (67.2+/- 4.6) h, (70.2 +/- 5.8) h and (69.2 +/- 6.2)h, respectively. No significant differences were observed among three groups(P > 0.05). The rate of postoperative anastomotic inflammation was 3.0 % (5/164) in the BAR group, 47.8 % (76/159) in hand-sutured group and 7.1 % (8/113) in the linear cutter group. The difference was significant statistically (P <0.05). The rate of postoperative anastomotic inflammation in the BAR group and in the linear cutter group was less than that in hand-sutured group. BAR is one of rapid,safe and effective methods in intestinal anastomosis. It has less anastomotic inflammatory reaction than hand-sutured technique. It should be considered equal to manual and stapler methods.

  16. Ergonomic Analysis of the Work Condition in Aluminum Crafts Industry

    NASA Astrophysics Data System (ADS)

    Soewardi, H.; Taufiq, A.; Pradipta, T.

    2017-12-01

    Indonesia has plenty of abundant natural wealth. This natural wealth produces natural materials that can be utilized as a craft product. The craft workers generally still work manually and the work is done repeatedly in one cycle so it is very susceptible to musculoskeletal disorders. Musculoskeletal disorders will cause decrease of worker’s effectiveness and efficiency in completing the task. Thus, this fact has some adverse impact for the company. The purpose of this study is to analyze some task in manufacturing a traditional cooking tool (griddle) which encompasses mold of the griddle, refine of the griddle and the finishing touch by using the Occupational Repetitive Action Index (OCRA index) method. This method consists of high frequency movements, large forces, awkward postures, insufficient resting time and other factor such as vibration. Result of this study shows that in the molding operation, the worker has uncertain and medium risk on right hand in manufacturing small and large size of griddle with OCRA index is 2.5 and 5.3 respectively. In the refining operation the worker has light and medium risk on left hand in manufacturing small and large size with OCRA index is 3.6 and 5.8 using grinding machine and 5.8, 5.2, 6.3 and 5.0 using miser tool. In finishing operation, the worker has high risk on right hand in numbering of code griddle and has medium risk on right hand and medium on left hand in labeling with OCRA index is 9, 6.1 and 6.8 While in assembling operation the worker has no risk. Score that it indicates the risk level of the task in such job. Thus the following actions are to improve the work condition ergonomicly in all operation in alumunium craft.

  17. A cognitive operating system (COGNOSYS) for JPL's robot, phase 1 report

    NASA Technical Reports Server (NTRS)

    Mathur, F. P.

    1972-01-01

    The most important software requirement for any robot development is the COGNitive Operating SYStem (COGNOSYS). This report describes the Stanford University Artificial Intelligence Laboratory's hand eye software system from the point of view of developing a cognitive operating system for JPL's robot. In this, the Phase 1 of the JPL robot COGNOSYS task the installation of a SAIL compiler and a FAIL assembler on Caltech's PDP-10 have been accomplished and guidelines have been prepared for the implementation of a Stanford University type hand eye software system on JPL-Caltech's computing facility. The alternatives offered by using RAND-USC's PDP-10 Tenex operating sytem are also considered.

  18. Dose-response relations between second-hand smoke exposure and depressive symptoms among middle-aged women.

    PubMed

    Ye, Xiaohua; Li, LiXia; Gao, Yanhui; Zhou, Shudong; Yang, Yi; Chen, Sidong

    2015-09-30

    A growing body of evidence indicates a strong association between smoking and depression. However, little is known about the possible effects of second-hand smoke (SHS) exposure on depression. This study aimed to examine the potential dose-response relation between SHS exposure and depressive symptoms among non-smoking middle-aged women. A cross-sectional survey was conducted using a stratified three-stage sampling method. Depressive symptoms were measured by the Center for Epidemiologic Studies Depression Scale with a cut-off point of 16. Self-reported SHS exposure was defined as non-smokers׳ inhalation of the smoke exhaled from smokers on at least one day a week. The multivariable logistic regression analysis was completed with adjustment for potential confounders. Among 1280 middle-aged women, 19.4% were classified as having depressive symptoms. There was a 104% increased odds of depressive symptoms corresponding to SHS exposure in general (OR=2.04, 95% CI 1.48-2.79) using no exposure as reference. There were significant positive relations between SHS exposure in general and depressive symptoms in a dose-response manner. These significant trends were observed consistently whether SHS exposure occurred in homes or workplaces. Our findings suggest that long-term and regular SHS exposure is associated with a significant, dose-dependent increase in risk of depressive symptoms. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Low-dose CT reconstruction with patch based sparsity and similarity constraints

    NASA Astrophysics Data System (ADS)

    Xu, Qiong; Mou, Xuanqin

    2014-03-01

    As the rapid growth of CT based medical application, low-dose CT reconstruction becomes more and more important to human health. Compared with other methods, statistical iterative reconstruction (SIR) usually performs better in lowdose case. However, the reconstructed image quality of SIR highly depends on the prior based regularization due to the insufficient of low-dose data. The frequently-used regularization is developed from pixel based prior, such as the smoothness between adjacent pixels. This kind of pixel based constraint cannot distinguish noise and structures effectively. Recently, patch based methods, such as dictionary learning and non-local means filtering, have outperformed the conventional pixel based methods. Patch is a small area of image, which expresses structural information of image. In this paper, we propose to use patch based constraint to improve the image quality of low-dose CT reconstruction. In the SIR framework, both patch based sparsity and similarity are considered in the regularization term. On one hand, patch based sparsity is addressed by sparse representation and dictionary learning methods, on the other hand, patch based similarity is addressed by non-local means filtering method. We conducted a real data experiment to evaluate the proposed method. The experimental results validate this method can lead to better image with less noise and more detail than other methods in low-count and few-views cases.

  20. Validation of Clinical Testing for Warfarin Sensitivity

    PubMed Central

    Langley, Michael R.; Booker, Jessica K.; Evans, James P.; McLeod, Howard L.; Weck, Karen E.

    2009-01-01

    Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 −1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses. PMID:19324988

  1. In vivo activity assessment of a "honey-bee pollen mix" formulation.

    PubMed

    Küpeli Akkol, Esra; Orhan, Didem Deliorman; Gürbüz, Ilhan; Yesilada, Erdem

    2010-03-01

    Honey-bee pollen mix (HBM) formulation is claimed to be effective for the treatment of asthma, bronchitis, cancers, peptic ulcers, colitis, various types of infections including hepatitis B, and rheumatism by the herb dealers in northeast Turkey. In the present study, in vivo antinociceptive, anti-inflammatory, gastroprotective and antioxidant effects of pure honey and HBM formulation were evaluated comparatively. HBM did not show any significant gastroprotective activity in a single administration at 250 mg/kg dose, whereas a weak activity was observed after three days of successive administration at 500 mg/kg dose. On the other hand, HBM displayed significant antinociceptive (p <0.01) and anti-inflammatory (p <0.01) activities at 500 mg/kg dose orally without inducing any apparent acute toxicity or gastric damage. HBM was also shown to possess potent antilipidperoxidant activity (p <0.01) at 500 mg/kg dose against acetaminophen-induced liver necrosis model in mice. On the other hand, pure honey did not exert any remarkable antinociceptive, anti-inflammatory and gastroprotective activity, but a potent antilipidperoxidant activity (p <0.01) was determined. Results have clearly proved that mixing pure honey with bee pollen significantly increased the healing potential of honey and provided additional support for its traditional use. Total phenolic and flavonoid contents of HBM were found to be 145 and 59.3 mg/100 g of honey, which were estimated as gallic acid and quercetin equivalents, respectively.

  2. Medical and occupational dose reduction in pediatric barium meal procedures

    NASA Astrophysics Data System (ADS)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Ledesma, J. A.; Legnani, A.; Bunick, A. P.; Sauzen, J.; Yagui, A.; Vosiak, P.

    2017-11-01

    Doses received in pediatric Barium Meal procedure can be rather high. It is possible to reduce dose values following the recommendations of the European Communities (EC) and the International Commission on Radiological Protection (ICRP). In the present work, the modifications of radiographic techniques made in a Brazilian hospital according to the EC and the ICRP recommendations and their influence on medical and occupational exposure are reported. The procedures of 49 patients before and 44 after the optimization were studied and air kerma-area product (PK,A) values and the effective doses were evaluated. The occupational equivalent doses were measured next to the eyes, under the thyroid shield and on each hand of both professionals who remained inside the examination room. The implemented modifications reduced by 70% and 60% the PK,A and the patient effective dose, respectively. The obtained dose values are lower than approximately 75% of the results from similar studies. The occupational annual equivalent doses for all studied organs became lower than the limits set by the ICRP. The equivalent doses in one examination were on average below than 75% of similar studies.

  3. Assessment of coarse and fine hand motor performance in asymptomatic subjects exposed to hand-arm vibration.

    PubMed

    Popević, Martin B; Janković, Srđan M; Borjanović, Srđan S; Jovičić, Slavica R; Tenjović, Lazar R; Milovanović, Aleksandar P S; Bulat, Petar

    2014-03-01

    A frequently encountered exposure profile for hand-arm vibration in contemporary occupational setting comprises workers with a long history of intermittent exposure but without detectable signs of hand-arm vibration syndrome (HAVS). Yet, most of the published studies deal with developed HAVS cases, rarely discussing the biological processes that may be involved in degradation of manual dexterity and grip strength when it can be most beneficial - during the asymptomatic stage. In the present paper, a group of 31 male asymptomatic vibration-exposed workers (according to the Stockholm Workshop Scale) were compared against 30 male controls. They were tested using dynamometry and dexterimetry (modelling coarse and fine manual performance respectively) and cold provocation was done to detect possible differences in manual performance drop on these tests. The results showed reduced manual dexterity but no significant degradation in hand grip strength in the exposed subjects. This suggests that intermittent exposure profile and small cumulative vibration dose could only lead to a measurable deficit in manual dexterity but not hand grip strength even at non-negligible A(8) levels and long term exposures.

  4. Ergonomic comparison of operating a built-in touch-pad pointing device and a trackball mouse on posture and muscle activity.

    PubMed

    Lee, Tzu-Hsien

    2005-12-01

    This study examined the effects of operating a built-in touch-pad pointing device and a trackball mouse on participants' completion times, hand positions during operation, postural angles, and muscle activities. 8 young men were asked to perform a cursor travel task on a notebook computer using both 60- and 80-cm high table conditions. Analysis showed that the trackball mouse significantly decreased completion times. Participants selected a hand position farther from the table edge and larger elbow angle for the trackball mouse than for the built-in touch-pad pointing device. Participants' neck, thoracic, and arm angles, or splenius capitis, trapezius, deltoid, and erector spinae muscle activities were not significantly affected by the devices, but table height significantly affected participants' completion times, hand positions, and postural angles.

  5. Characterization of the radiation environment at the UNLV accelerator facility during operation of the Varian M6 linac

    NASA Astrophysics Data System (ADS)

    Hodges, M.; Barzilov, A.; Chen, Y.; Lowe, D.

    2016-10-01

    The bremsstrahlung photon flux from the UNLV particle accelerator (Varian M6 model) was determined using MCNP5 code for 3 MeV and 6 MeV incident electrons. Human biological equivalent dose rates due to accelerator operation were evaluated using the photon flux with the flux-to-dose conversion factors. Dose rates were computed for the accelerator facility for M6 linac use under different operating conditions. The results showed that the use of collimators and linac internal shielding significantly reduced the dose rates throughout the facility. It was shown that the walls of the facility, in addition to the earthen berm enveloping the building, provide equivalent shielding to reduce dose rates outside to below the 2 mrem/h limit.

  6. Accuracy of tablet splitting and liquid measurements: an examination of who, what and how.

    PubMed

    Abu-Geras, Dana; Hadziomerovic, Dunja; Leau, Andrew; Khan, Ramzan Nazim; Gudka, Sajni; Locher, Cornelia; Razaghikashani, Maryam; Lim, Lee Yong

    2017-05-01

    To examine factors that might affect the ability of patients to accurately halve tablets or measure a 5-ml liquid dose. Eighty-eight participants split four different placebo tablets by hand and using a tablet splitter, while 85 participants measured 5 ml of water, 0.5% methylcellulose (MC) and 1% MC using a syringe and dosing cup. Accuracy of manipulation was determined by mass measurements. The general population was less able than pharmacy students to break tablets into equal parts, although age, gender and prior experience were insignificant factors. Greater accuracy of tablet halving was observed with tablet splitter, with scored tablets split more equally than unscored tablets. Tablet size did not affect the accuracy of splitting. However, >25% of small scored tablets failed to be split by hand, and 41% of large unscored tablets were split into >2 portions in the tablet splitter. In liquid measurement, the syringe provided more accurate volume measurements than the dosing cup, with higher accuracy observed for the more viscous MC solutions than water. Formulation characteristics and manipulation technique have greater influences on the accuracy of medication modification and should be considered in off-label drug use in vulnerable populations. © 2016 Royal Pharmaceutical Society.

  7. 49 CFR 236.202 - Signal governing movements over hand-operated switch.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... THE INSTALLATION, INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Block Signal Systems Standards § 236.202 Signal governing movements over hand...

  8. Using two detectors concurrently to monitor ambient dose equivalent rates in vehicle surveys of radiocesium contaminated land.

    PubMed

    Takeishi, Minoru; Shibamichi, Masaru; Malins, Alex; Kurikami, Hiroshi; Murakami, Mitsuhiro; Saegusa, Jun; Yoneya, Masayuki

    2017-10-01

    In response to the accident at Tokyo Electric Power Company's Fukushima Dai-ichi Nuclear Power Plant (FDNPP), vehicle-borne monitoring was used to map radiation levels for radiological protection of the public. By convention measurements from vehicle-borne surveys are converted to the ambient dose equivalent rate at 1 m height in the absence of the vehicle. This allows for comparison with results from other types of survey, including surveys with hand-held or airborne instruments. To improve the accuracy of the converted results from vehicle-borne surveys, we investigated combining measurements from two detectors mounted on the vehicle at different heights above the ground. A dual-detector setup was added to a JAEA monitoring car and compared against hand-held survey meter measurements in Fukushima Prefecture. The results obtained by combining measurements from two detectors were within ±20% of the hand-held reference measurements. The mean absolute percentage deviation from the reference measurements was 7.2%. The combined results from the two detectors were more accurate than those from either the roof-mounted detector, or the detector inside the vehicle, taken alone. One issue with vehicle-borne surveys is that ambient dose equivalent rates above roads are not necessarily representative of adjacent areas. This is because radiocesium is often deficient on asphalt surfaces, as it is easily scrubbed off by rain, wind and vehicle tires. To tackle this issue, we investigated mounting heights for vehicle-borne detectors using Monte Carlo gamma-ray simulations. When radiocesium is deficient on a road compared to the adjacent land, mounting detectors high on vehicles yields results closer to the values adjacent to the road. The ratio of ambient dose equivalent rates reported by detectors mounted at different heights in a dual-detector setup indicates whether radiocesium is deficient on the road compared to the adjacent land. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. [Application of hand-use ProTaper instruments in endodontic treatment of molar canals].

    PubMed

    Ma, Sui-qi; Xie, Qian; Zhou, Yin-feng

    2010-07-01

    To evaluate the application of hand-use ProTaper instruments in endodontic treatment of molar canals. A total of 203 permanent molars were randomly divided into the experimental group (99 molars) and control group (104 molars) prepared by hand-use ProTaper instruments and standard stainless steel K-file, respectively. The molars in the two groups were obturated by cold lateral condensation technique. The root canal preparation and obturation were evaluated by radiograph, and the working time of preparation and post-operative emergencies were analyzed. The preparation time in the experimental group was obviously shorter than that in the control group (P<0.01). The rate of satisfactory effect was significantly higher in the experimental group than in the control group (P<0.01), and the rate of post-operative emergencies was significantly lower in the experimental group (P<0.01). The application of hand-use ProTaper instruments may improve the effect of root canal treatment of the molars and shorten the working time and reduce the post-operative emergencies.

  10. Mechanisms for employment with robotic extensions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Salisbury, Curt Michael; Dullea, Kevin J.

    Technologies pertaining to a robotic hand are described herein. A protection apparatus is positioned in a joint of the robotic hand, where movement of a link about the joint is driven by a motor. The protection apparatus absorbs torque about the joint caused by an external force. At least a portion of the robotic hand can be covered by an anthropomorphic skin. An apparatus suitable for controlling operation of the robotic hand is also described herein.

  11. Personnel dose reduction in 90Y microspheres liver-directed radioembolization: from interventional radiology suite to patient ward

    PubMed Central

    Wong, K K; Tso, W K; Lee, Victor; Luk, M Y; Tong, C C; Chu, Ferdinand

    2017-01-01

    Objective: To describe a method to reduce the external radiation exposure emitted from the patient after liver-directed radioembolization using 90Y glass microspheres, to quantitatively estimate the occupational dose of medical personnel providing patient care to the patient radioembolized with the use of the method and to discuss radiation exposure to patients who are adjacent if the patient radioembolized needs hospitalization. Methods: A lead-lined blanket of lead equivalence of 0.5 mm was used to cover the patient abdomen immediately after the 90Y radioembolization procedure, in order to reduce the radiation emitted from the patient. The interventional radiologist used a rod-type puncture site compressor for haemostasis to avoid direct contact with possible residual radioactivity at the puncture site. Dose rates were measured at the interventional radiologist chest and hand positions during puncture site pressing for haemostasis with and without the use of the blanket. The measurement results were applied to estimate the occupational dose of colleagues performing patient care to the patient radioembolized. The exposure to patients adjacent in the ward was estimated if the patient radioembolized was hospitalized. Results: The radiation exposures measured at the radiologist chest and hand positions have been significantly reduced with the lead-lined blanket in place. The radiologist, performing puncture site pressing at the end of radioembolization procedure, would receive an average hand dose of 1.95 μSv and body dose under his own lead apron of 0.30 μSv for an average 90Y microsphere radioactivity of 2.54 GBq. Other medical personnel, nurses and porters, would receive occupational doses corresponding to an hour of background radiation. If the patient radioembolized using 90Y needs hospitalization in a common ward, using the lead-lined blanket to cover the abdomen of the patient and keeping a distance of 2 m from the patient who is adjacent would reduce the exposure by 0.42% of dose limit for the general public. Conclusion: By placing a lead-lined blanket on the patient abdominal region after 90Y radioembolization, hospital staff receive minimal radiation exposure in order to comply with the radiation protection “as low as reasonably achievable” principle. There will be no increase in radiation level in ward if the patient radioembolized using 90Y needs to be hospitalized. Therefore, the patient radioembolized can be accommodated alternatively at a corner bed of a common ward if an isolation room with private toilet facility is not available. Advances in knowledge: To reduce exposure to personnel providing patient care to patients radioembolized using 90Y. PMID:27993095

  12. Portable rapid and quiet drill

    NASA Technical Reports Server (NTRS)

    Badescu, Mireca (Inventor); Chang, Zenshea (Inventor); Sherrit, Stewart (Inventor); Bar-Cohen, Yoseph (Inventor); Bao, Xiaoqi (Inventor)

    2010-01-01

    A hand-held drilling device, and method for drilling using the device, has a housing, a transducer within the housing, with the transducer effectively operating at ultrasonic frequencies, a rotating motor component within the housing and rigid cutting end-effector rotationally connected to the rotating motor component and vibrationally connected to the transducer. The hand-held drilling device of the present invention operates at a noise level of from about 50 decibels or less.

  13. Opioid receptor mediated anticonvulsant effect of pentazocine.

    PubMed

    Khanna, N; Khosla, R; Kohli, J

    1998-01-01

    Intraperitoneal (i.p.) administration of (+/-) pentazocine (10, 30 & 50 mg/kg), a Sigma opioid agonist, resulted in a dose dependent anticonvulsant action against maximal electroshock seizures in mice. This anticonvulsant effect of pentazocine was not antagonized by both the doses of naloxone (1 and 10 mg/kg) suggesting thereby that its anticonvulsant action is probably mediated by Sigma opiate binding sites. Its anticonvulsant effect was potentiated by both the anticonvulsant drugs viz. diazepam and diphenylhydantoin. Morphine, mu opioid agonist, on the other hand, failed to protect the animals against maximal electroshock seizures when it was given in doses of 10-40 mg/kg body wt.

  14. AXAOTHER XL -- A spreadsheet for determining doses for incidents caused by tornadoes or high-velocity straight winds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simpkins, A.A.

    1996-09-01

    AXAOTHER XL is an Excel Spreadsheet used to determine dose to the maximally exposed offsite individual during high-velocity straight winds or tornado conditions. Both individual and population doses may be considered. Potential exposure pathways are inhalation and plume shine. For high-velocity straight winds the spreadsheet has the capability to determine the downwind relative air concentration, however for the tornado conditions, the user must enter the relative air concentration. Theoretical models are discussed and hand calculations are performed to ensure proper application of methodologies. A section has also been included that contains user instructions for the spreadsheet.

  15. Compliance and effective management of the hand-foot syndrome in colon cancer patients receiving capecitabine as adjuvant chemotherapy.

    PubMed

    Son, Hyun-Sook; Lee, Woo Yong; Lee, Won-Suk; Yun, Seong Hyeon; Chun, Ho-Kyung

    2009-12-31

    Physicians and oncology nurses must continue to update their knowledge on treatment and treatment-related side effects, while searching for effective methods to prevent or manage side effects. The objective of our study was to describe the incidence and response to treatment of the hand-foot syndrome (HFS) and the compliance with treatment of patients with stage IIB, IIIA, IIIB, and IIIC colon cancer that were treated with capecitabine alone as adjuvant therapy. Between September 2005 and September 2006, 84 patients fulfilled the inclusion criteria and were included in this retrospective analysis of prospectively collected data. The treatment compliance rate was 90.5% (76 out of the 84 patients). The HFS developed in 65 patients (77.4%). Thirty-three patients (50.7%) had grade 1 HFS, 22 patients (33.8%) had grade 2 HFS and 10 patients (15.5%) had grade 3 HFS, as their most severe episode. For Grade 1 patients, the dose was maintained, and skin barrier cream and moist exposed burn ointment (MEBO) were applied. For Grade 2 patients, either the dose was maintained or 25% of the dose was reduced; MEBO and supportive care were provided. For Grade 3 patients, one cycle of chemotherapy was interrupted followed by dose adjustment; MEBO and supportive care were provided. HFS is manageable if both patients and oncology care teams are educated about HFS associated with capecitabine. The HFS is treated by patient education, preventive management, ointment application, conservative management, dose reduction, and interruption of chemotherapy administration.

  16. [Mechanisms of opioid-induced overdose: experimental approach to clinical concerns].

    PubMed

    Baud, F-J

    2009-09-01

    The widely used term "overdose" denotes a toxic effect: opioid-induced intoxication and a mechanism: the poisoning results only from an overdose. Surprisingly, our understanding of the pathophysiology of this deadly complication is limited. In drug users, we attempted to: (1) improve knowledge of drug-induced respiratory effects; (2) clarify the mechanisms of drug interactions; (3) identify factors of variability and vulnerability. A prospective study of opioid overdoses confirmed that poisonings involving buprenorphine do exist. However, the mechanisms of buprenorphine poisoning are more complex than only an overdose, particularly the severity is less than that induced by heroin. In contrast, methadone overdose is life-threatening. Experimental studies addressed several clinical questions and also showed limited discrepancies. At pharmacological doses, opioids decrease the ventilatory response to CO(2). However, this effect does not account for the morbimortality of opioid poisonings. The mechanisms of opioid-induced morbimortality are different. Buprenorphine at doses near its median lethal dose did not induce acute respiratory failure as defined by a decrease in the partial pressure of oxygen in arterial blood (PaO(2)). In contrast, the combination of buprenorphine with flunitrazepam results in a decrease in PaO(2). This harmful interaction does not exist with other benzodiazepines in the rat, except for very high doses of nordazepam. The interaction results from a pharmacokinetic process. In contrast, methadone causes a dose-dependent decrease in PaO(2,) even significant before hypercapnia. We are assessing the relationships between on one hand alterations of ventilatory pattern and of arterial blood gas and on the other hand the different types of opiate receptors in the rats.

  17. Scar Management of the Burned Hand

    PubMed Central

    Sorkin, Michael; Cholok, David; Levi, Benjamin

    2017-01-01

    Unimpaired hand function is critical in almost all activities of daily living. Burn injury can result in hypertrophic scar formation that can lead to debilitating functional deficits and poor aesthetic outcomes. Initial algorithms of acute burn management involve early debridement and skin grafting and early mobilization to prevent formation of hypertrophic scarring and ultimately digit contractures. While non-operative modalities in the early phase of scar maturation are critical to minimize hypertrophic scar formation, surgical management is often indicated in order to restore hand function. The essential tenant of operative scar management is release of tension, which can often be achieved through local tissue rearrangement. Laser therapy has emerged as a central pillar of subsequent scar rehabilitation with several modalities that address scar texture, color, pruritis and thickness. These can be utilized in conjunction with local corticosteroid treatment and other emerging modalities to modulate the scar and achieve optimal hand function. These treatment tools provide an effective resource for the reconstructive surgeon to treat hypertrophic hand scars. PMID:28363297

  18. Agent Orange Exposure and Monoclonal Gammopathy of Undetermined Significance: An Operation Ranch Hand Veteran Cohort Study.

    PubMed

    Landgren, Ola; Shim, Youn K; Michalek, Joel; Costello, Rene; Burton, Debra; Ketchum, Norma; Calvo, Katherine R; Caporaso, Neil; Raveche, Elizabeth; Middleton, Dan; Marti, Gerald; Vogt, Robert F

    2015-11-01

    Multiple myeloma has been classified as exhibiting "limited or suggestive evidence" of an association with exposure to herbicides in Vietnam War veterans. Occupational studies have shown that other pesticides (ie, insecticides, herbicides, fungicides) are associated with excess risk of multiple myeloma and its precursor state, monoclonal gammopathy of undetermined significance (MGUS); however, to our knowledge, no studies have uncovered such an association in Vietnam War veterans. To examine the relationship between MGUS and exposure to Agent Orange, including its contaminant 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD), in Vietnam War veterans. This was a prospective cohort study conducted in 2013 to 2014, testing for MGUS in serum specimens collected and stored in 2002 by the Air Force Health Study (AFHS). The relevant exposure data collected by the AFHS was also used. We tested all specimens in 2013 without knowledge of the exposure status. The AFHS included former US Air Force personnel who participated in Operation Ranch Hand (Ranch Hand veterans) and other US Air Force personnel who had similar duties in Southeast Asia during the same time period (1962 to 1971) but were not involved in herbicide spray missions (comparison veterans). Agent Orange was used by the US Air Force personnel who conducted aerial spray missions of herbicides (Operation Ranch Hand) in Vietnam from 1962 to 1971. We included 479 Ranch Hand veterans and 479 comparison veterans who participated in the 2002 follow-up examination of AFHS. Agent Orange and TCDD. Serum TCDD levels were measured in 1987, 1992, 1997, and 2002. Risk of MGUS measured by prevalence, odds ratios (ORs), and 95% CIs. The 479 Ranch Hand veterans and 479 comparison veterans had similar demographic and lifestyle characteristics and medical histories. The crude prevalence of overall MGUS was 7.1% (34 of 479) in Ranch Hand veterans and 3.1% (15 of 479) in comparison veterans. This translated into a 2.4-fold increased risk for MGUS in Ranch Hand veterans than comparison veterans after adjusting for age, race, BMI in 2002, and the change in BMI between 2002 and the time of blood draw for TCDD measurement (adjusted OR, 2.37; 95% CI, 1.27-4.44; P=.007). Operation Ranch Hand veterans have a significantly increased risk of MGUS, supporting an association between Agent Orange exposure and multiple myeloma.

  19. Mobile Phone Use Behaviors and Postures on Public Transportation Systems

    PubMed Central

    Liang, Huey-Wen; Hwang, Yaw-Huei

    2016-01-01

    Mobile phones are common in our daily life, but the users’ preferences for postures or screen operating styles have not been studied. This was a cross-sectional and observational study. We randomly sampled passengers who used mobile phones on the Mass Rapid Transit (MRT) system in metropolitan Taipei. A checklist was used to observe their body postures and screen operating styles while sitting or standing. As a result, 1,230 subjects from 400 trips were observed. Overall, of all the passengers who were sitting, 41% of them were using mobile phones. The majority of the tasks involved browsing (84%) with their phones in a portrait orientation (93%). Different-hand holding/operating was the most commonly used operating style while sitting (46%) and same-hand holding/operating was the most common while standing (46%). The distribution of screen operating styles was significantly different for those sitting than for those standing and for different genders and age groups. The most frequently observed postures while sitting were having one’s trunk against a backrest, feet on the floor and with or without an arm supported (58%). As for the users who were standing, the both- and different-hands groups had a high proportion of arms unsupported, feet on the floor and either their trunk supported or not. In contrast, the same-hand group tended to have their trunk unsupported, were holding a pole or handstrap and had both feet on floor. Further studies are warranted to characterize the ergonomic exposure of these commonly used postures and operating styles, and our results will help guide the selection of experimental conditions for laboratory settings. PMID:26828797

  20. Effect of Time Interval Between Tumescent Local Anesthesia Infiltration and Start of Surgery on Operative Field Visibility in Hand Surgery Without Tourniquet.

    PubMed

    Bashir, Muhammad Mustehsan; Qayyum, Rehan; Saleem, Muhammad Hammad; Siddique, Kashif; Khan, Farid Ahmad

    2015-08-01

    To determine the optimal time interval between tumescent local anesthesia infiltration and the start of hand surgery without a tourniquet for improved operative field visibility. Patients aged 16 to 60 years who needed contracture release and tendon repair in the hand were enrolled from the outpatient clinic. Patients were randomized to 10-, 15-, or 25-minute intervals between tumescent anesthetic solution infiltration (0.18% lidocaine and 1:221,000 epinephrine) and the start of surgery. The end point of tumescence anesthetic infiltration was pale and firm skin. The surgical team was blinded to the time of anesthetic infiltration. At the completion of the procedure, the surgeon and the first assistant rated the operative field visibility as excellent, fair, or poor. We used logistic regression models without and with adjustment for confounding variables. Of the 75 patients enrolled in the study, 59 (79%) were males, 7 were randomized to 10-minute time intervals (further randomization was stopped after interim analysis found consistently poor operative field visibility), and 34 were randomized to the each of the 15- and 25-minute groups. Patients who were randomized to the 25-minute delay group had 29 times higher odds of having an excellent operative visual field than those randomized to the 15-minute delay group. After adjusting for age, sex, amount of tumescent solution infiltration, and duration of operation, the odds ratio remained highly significant. We found that an interval of 25 minutes provides vastly superior operative field visibility; 10-minute delay had the poorest results. Therapeutic I. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Calculation of Dose, Dose Equivalent, and Relative Biological Effectiveness for High Charge and Energy Ion Beams

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; Reginatto, M.; Hajnal, F.; Chun, S. Y.

    1995-01-01

    The Green's function for the transport of ions of high charge and energy is utilized with a nuclear fragmentation database to evaluate dose, dose equivalent, and RBE for C3H1OT1/2 cell survival and neoplastic transformation as a function of depth in soft tissue. Such evaluations are useful to estimates of biological risk for high altitude aircraft, space operations, accelerator operations, and biomedical applications.

  2. Calculation of dose, dose equivalent, and relative biological effectiveness for high charge and energy ion beams

    NASA Technical Reports Server (NTRS)

    Wilson, J. W.; Chun, S. Y.; Reginatto, M.; Hajnal, F.

    1995-01-01

    The Green's function for the transport of ions of high charge and energy is utilized with a nuclear fragmentation database to evaluate dose, dose equivalent, and RBE for C3H10T1/2 cell survival and neo-plastic transformation as function of depth in soft tissue. Such evaluations are useful to estimates of biological risk for high altitude aircraft, space operations, accelerator operations, and biomedical application.

  3. Comparison of manual and mechanical cervical esophagogastric anastomosis after esophageal resection for squamous cell carcinoma: a prospective randomized controlled trial.

    PubMed

    Hsu, Hsao-Hsun; Chen, Jin-Shing; Huang, Pei-Ming; Lee, Jang-Ming; Lee, Yung-Chie

    2004-06-01

    The use of a circular stapler in cervical esophagogastric anastomosis remains controversial. This study was to compare the postoperative and long-term results of manual and mechanical techniques for cervical esophagogastric anastomosis after resection for squamous cell carcinoma. A prospective randomized controlled trial was undertaken in 63 patients with curatively resectable squamous cell cancer of the thoracic esophagus between 1996 and 1999. Patients were randomized to receive either a hand-sewn (32 patients) or circular stapled (31 patients) cervical esophagogastric anastomosis. The mean operating time was longer when the hand-sewn method was used (524 vs. 447 min, P < 0.001). Anastomotic leakage was noted in seven patients (22%) in the hand-sewn group and eight patients (26%) in the stapler group (P = NS). Hospital mortality occurred in four patients (13%) of the hand-sewn group and in three patients (10%) of the stapler group (P = NS). After the operation, four patients (14%) in the hand-sewn group and five patients (18%) in the stapler group developed a benign esophageal stricture (P = NS). The mean follow-up time was 24 months, and the rates of freedom from benign stricture and survival were comparable in each group. Performing cervical esophagogastric anastomoses using a circular mechanical stapler had a shorter operating time and a comparable outcome to the hand-sewn method. The circular mechanical stapler could be used as an alternative for cervical esophagogastric anastomosis after resection for esophageal squamous cell cancer.

  4. Occupational Safety. Hand Tools. Pre-Apprenticeship Phase 1 Training.

    ERIC Educational Resources Information Center

    Lane Community Coll., Eugene, OR.

    This self-paced student training module on safety when using hand tools is one of a number of modules developed for Pre-apprenticeship Phase 1 Training. Purpose of the module is to teach students the correct safety techniques for operating common hand- and arm-powered tools, including selection, maintenance, technique, and uses. The module may…

  5. Evaluation of a new very low dose imaging protocol: feasibility and impact on X-ray dose levels in electrophysiology procedures.

    PubMed

    Bourier, Felix; Reents, Tilko; Ammar-Busch, Sonia; Buiatti, Alessandra; Kottmaier, Marc; Semmler, Verena; Telishevska, Marta; Brkic, Amir; Grebmer, Christian; Lennerz, Carsten; Kolb, Christof; Hessling, Gabriele; Deisenhofer, Isabel

    2016-09-01

    This study presents and evaluates the impact of a new lowest-dose fluoroscopy protocol (Siemens AG), especially designed for electrophysiology (EP) procedures, on X-ray dose levels. From October 2014 to March 2015, 140 patients underwent an EP study on an Artis zee angiography system. The standard low-dose protocol was operated at 23 nGy (fluoroscopy) and at 120 nGy (cine-loop), the new lowest-dose protocol was operated at 8 nGy (fluoroscopy) and at 36 nGy (cine-loop). Procedural data, X-ray times, and doses were analysed in 100 complex left atrial and in 40 standard EP procedures. The resulting dose-area products were 877.9 ± 624.7 µGym² (n = 50 complex procedures, standard low dose), 199 ± 159.6 µGym² (n = 50 complex procedures, lowest dose), 387.7 ± 36.0 µGym² (n = 20 standard procedures, standard low dose), and 90.7 ± 62.3 µGym² (n = 20 standard procedures, lowest dose), P < 0.01. In the low-dose and lowest-dose groups, procedure times were 132.6 ± 35.7 vs. 126.7 ± 34.7 min (P = 0.40, complex procedures) and 72.3 ± 20.9 vs. 85.2 ± 44.1 min (P = 0.24, standard procedures), radiofrequency (RF) times were 53.8 ± 26.1 vs. 50.4 ± 29.4 min (P = 0.54, complex procedures) and 10.1 ± 9.9 vs. 12.2 ± 14.7 min (P = 0.60, standard procedures). One complication occurred in the standard low-dose and lowest-dose groups (P = 1.0). The new lowest-dose imaging protocol reduces X-ray dose levels by 77% compared with the currently available standard low-dose protocol. From an operator standpoint, lowest X-ray dose levels create a different, reduced image quality. The new image quality did not significantly affect procedure or RF times and did not result in higher complication rates. Regarding radiological protection, operating at lowest-dose settings should become standard in EP procedures. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  6. The Jet Propulsion Laboratory shared control architecture and implementation

    NASA Technical Reports Server (NTRS)

    Backes, Paul G.; Hayati, Samad

    1990-01-01

    A hardware and software environment for shared control of telerobot task execution has been implemented. Modes of task execution range from fully teleoperated to fully autonomous as well as shared where hand controller inputs from the human operator are mixed with autonomous system inputs in real time. The objective of the shared control environment is to aid the telerobot operator during task execution by merging real-time operator control from hand controllers with autonomous control to simplify task execution for the operator. The operator is the principal command source and can assign as much autonomy for a task as desired. The shared control hardware environment consists of two PUMA 560 robots, two 6-axis force reflecting hand controllers, Universal Motor Controllers for each of the robots and hand controllers, a SUN4 computer, and VME chassis containing 68020 processors and input/output boards. The operator interface for shared control, the User Macro Interface (UMI), is a menu driven interface to design a task and assign the levels of teleoperated and autonomous control. The operator also sets up the system monitor which checks safety limits during task execution. Cartesian-space degrees of freedom for teleoperated and/or autonomous control inputs are selected within UMI as well as the weightings for the teleoperation and autonmous inputs. These are then used during task execution to determine the mix of teleoperation and autonomous inputs. Some of the autonomous control primitives available to the user are Joint-Guarded-Move, Cartesian-Guarded-Move, Move-To-Touch, Pin-Insertion/Removal, Door/Crank-Turn, Bolt-Turn, and Slide. The operator can execute a task using pure teleoperation or mix control execution from the autonomous primitives with teleoperated inputs. Presently the shared control environment supports single arm task execution. Work is presently underway to provide the shared control environment for dual arm control. Teleoperation during shared control is only Cartesian space control and no force-reflection is provided. Force-reflecting teleoperation and joint space operator inputs are planned extensions to the environment.

  7. Simulation-based educational curriculum for fluoroscopically guided lumbar puncture improves operator confidence and reduces patient dose.

    PubMed

    Faulkner, Austin R; Bourgeois, Austin C; Bradley, Yong C; Hudson, Kathleen B; Heidel, R Eric; Pasciak, Alexander S

    2015-05-01

    Fluoroscopically guided lumbar puncture (FGLP) is a commonly performed procedure with increased success rates relative to bedside technique. However, FGLP also exposes both patient and staff to ionizing radiation. The purpose of this study was to determine if the use of a simulation-based FGLP training program using an original, inexpensive lumbar spine phantom could improve operator confidence and efficiency, while also reducing patient dose. A didactic and simulation-based FGLP curriculum was designed, including a 1-hour lecture and hands-on training with a lumbar spine phantom prototype developed at our institution. Six incoming post-graduate year 2 (PGY-2) radiology residents completed a short survey before taking the course, and each resident practiced 20 simulated FGLPs using the phantom before their first clinical procedure. Data from the 114 lumbar punctures (LPs) performed by the six trained residents (prospective cohort) were compared to data from 514 LPs performed by 17 residents who did not receive simulation-based training (retrospective cohort). Fluoroscopy time (FT), FGLP success rate, and indication were compared. There was a statistically significant reduction in average FT for the 114 procedures performed by the prospective study cohort compared to the 514 procedures performed by the retrospective cohort. This held true for all procedures in aggregate, LPs for myelography, and all procedures performed for a diagnostic indication. Aggregate FT for the prospective group (0.87 ± 0.68 minutes) was significantly lower compared to the retrospective group (1.09 ± 0.65 minutes) and resulted in a 25% reduction in average FT (P = .002). There was no statistically significant difference in the number of failed FGLPs between the two groups. Our simulation-based FGLP curriculum resulted in improved operator confidence and reduced FT. These changes suggest that resident procedure efficiency was improved, whereas patient dose was reduced. The FGLP training program was implemented by radiology residents and required a minimal investment of time and resources. The LP spine phantom used during training was inexpensive, durable, and effective. In addition, the phantom is compatible with multiple modalities including fluoroscopy, computed tomography, and ultrasound and could be easily adapted to other applications such as facet injections or joint arthrograms. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  8. On a fundamental problem in radiation biology

    NASA Technical Reports Server (NTRS)

    Dugan, V.; Trujillo, R.

    1974-01-01

    Experimental evidence indicates that the radiation dose required to reduce a surviving population to a certain fraction of its original population is lower for vertebrate cells than for viruses. On the other hand, the number of ionizations per cell required to inactivate that cell is greater for vertebrate cells than for viruses. The apparent conflict between these two findings is investigated. It is found that the apparent contradiction is probably a result of the fractional power dependence of the radiation-dose value on the nucleic acid weight.

  9. Template-guided vs. non-guided drilling in site preparation of dental implants.

    PubMed

    Scherer, Uta; Stoetzer, Marcus; Ruecker, Martin; Gellrich, Nils-Claudius; von See, Constantin

    2015-07-01

    Clinical success of oral implants is related to primary stability and osseointegration. These parameters are associated with delicate surgical techniques. We herein studied whether template-guided drilling has a significant influence on drillholes diameter and accuracy in an in vitro model. Fresh cadaveric porcine mandibles were used for drilling experiments of four experimental groups. Each group consisted of three operators, comparing guide templates for drilling with free-handed procedure. Operators without surgical knowledge were grouped together, contrasting highly experienced oral surgeons in other groups. A total of 180 drilling actions were performed, and diameters were recorded at multiple depth levels, with a precision measuring instrument. Template-guided drilling procedure improved accuracy on a very significant level in comparison with free-handed drilling operation (p ≤ 0.001). Inaccuracy of free-handed drilling became more significant in relation to measurement depth. High homogenic uniformity of template-guided drillholes was significantly stronger than unguided drilling operations by highly experienced oral surgeons (p ≤ 0.001). Template-guided drilling procedure leads to significantly enhanced accuracy. Significant results compared to free-handed drilling actions were achieved, irrespective of the clinical experience level of the operator. Template-guided drilling procedures lead to a more predictable clinical diameter. It shows that any set of instruments has to be carefully chosen to match the specific implant system. The current in vitro study is implicating an improvement of implant bed preparation but needs to be confirmed in clinical studies.

  10. The effects of smartphone use on upper extremity muscle activity and pain threshold

    PubMed Central

    Lee, Minkyung; Hong, Yunkyung; Lee, Seunghoon; Won, Jinyoung; Yang, Jinjun; Park, Sookyoung; Chang, Kyu-Tae; Hong, Yonggeun

    2015-01-01

    [Purpose] The purpose of this study was to determine whether muscle activity and pressure-induced pain in the upper extremities are affected by smartphone use, and to compare the effects of phone handling with one hand and with both hands. [Subjects] The study subjects were asymptomatic women 20–22 years of age. [Methods] The subjects sat in a chair with their feet on the floor and the elbow flexed, holding a smartphone positioned on the thigh. Subsequently, the subjects typed the Korean anthem for 3 min, one-handed or with both hands. Each subject repeated the task three times, with a 5-min rest period between tasks to minimize fatigue. Electromyography (EMG) was used to record the muscle activity of the upper trapezius (UT), extensor pollicis longus (EPL), and abductor pollicis (AP) during phone operation. We also used a dolorimeter to measure the pressure-induced pain threshold in the UT. [Results] We observed higher muscle activity in the UT, AP, and EPL in one-handed smartphone use than in its two-handed use. The pressure-induced pain threshold of the UT was lower after use of the smartphone, especially after one-handed use. [Conclusion] Our results show that smartphone operation with one hand caused greater UT pain and induced increased upper extremity muscle activity. PMID:26180311

  11. Personal exposure to pesticide among workers engaged in pesticide container recycling operations.

    PubMed

    Guidotti, T L; Yoshida, K; Clough, V

    1994-12-01

    Pesticide container handling operations in western Canada were examined to determine the exposure of workers to residual pesticide in sorting, metal-container crushing, metal-container shredding, plastic-container shredding, metal washing, and metal melting. Environmental exposure monitoring and biological monitoring were applied, including measurement of pesticide deposition density on outer clothing (test coveralls and other protective wear), deposition on fabric and gauze patches under the outer clothing, inhalation of airborne pesticide residues, dislodgement of pesticide residues by hand washing, and pre- and postexposure urinary excretion of pesticide (2,4-D). Exposure levels were highly variable; some variability was accounted for by work practices or lapses in protection. The highest levels of exposure were observed for metal washing, metal crushing, and metal shredding; sorting and plastic shredding were intermediate, and metal melting was associated with very little exposure. Urinary 2,4-D excretion, as an indicator of internal dose, correlated most closely with exposure by the inhalation route, and both were highest for metal washing and shredding. Deposition of pesticide on garments was highest for metal crushing. Melting of washed metal does not appear to present a significant hazard of exposure. Recommendations are proposed for the protection of workers emphasizing health and safety guidelines, worker education, personal hygiene, exposure and health monitoring, and record-keeping, and specific recommendations for each process. These recommendations apply to all pesticide container recycling operations except melting of washed metal containers.

  12. Perceptual impairment and psychomotor control in virtual laparoscopic surgery.

    PubMed

    Wilson, Mark R; McGrath, John S; Vine, Samuel J; Brewer, James; Defriend, David; Masters, Richard S W

    2011-07-01

    It is recognised that one of the major difficulties in performing laparoscopic surgery is the translation of two-dimensional video image information to a three-dimensional working area. However, research has tended to ignore the gaze and eye-hand coordination strategies employed by laparoscopic surgeons as they attempt to overcome these perceptual constraints. This study sought to examine if measures related to tool movements, gaze strategy, and eye-hand coordination (the quiet eye) differentiate between experienced and novice operators performing a two-handed manoeuvres task on a virtual reality laparoscopic surgical simulator (LAP Mentor™). Twenty-five right-handed surgeons were categorised as being either experienced (having led more than 60 laparoscopic procedures) or novice (having performed fewer than 10 procedures) operators. The 10 experienced and 15 novice surgeons completed the "two-hand manoeuvres" task from the LAP Mentor basic skills learning environment while wearing a gaze registration system. Performance, movement, gaze, and eye-hand coordination parameters were recorded and compared between groups. The experienced surgeons completed the task significantly more quickly than the novices, used significantly fewer movements, and displayed shorter tool paths. Gaze analyses revealed that experienced surgeons spent significantly more time fixating the target locations than novices, who split their time between focusing on the targets and tracking the tools. A more detailed analysis of a difficult subcomponent of the task revealed that experienced operators used a significantly longer aiming fixation (the quiet eye period) to guide precision grasping movements and hence needed fewer grasp attempts. The findings of the study provide further support for the utility of examining strategic gaze behaviour and eye-hand coordination measures to help further our understanding of how experienced surgeons attempt to overcome the perceptual difficulties inherent in the laparoscopic environment.

  13. Dose assessment of aircraft crew in The Netherlands.

    PubMed

    Van Dijk, J W E

    2003-01-01

    As the operator of the National Dose Registration and Information System, NRG has implemented a system for radiation exposure monitoring for the Dutch airlines. The system is based on the use of computer generated flight plans together with dose calculations using the CARI-6M program. Before installing the system a study was performed to estimate the uncertainty in the assessment of the annual dose of the crew members. It was concluded that the proposed system complies with international recommendations on the uncertainty in dose assessments in individual monitoring and that the operational costs of the system are low.

  14. The Hand Burn Severity (HABS) score: A simple tool for stratifying severity of hand burns.

    PubMed

    Bache, Sarah E; Fitzgerald O'Connor, Edmund; Theodorakopoulou, Evgenia; Frew, Quentin; Philp, Bruce; Dziewulski, Peter

    2017-02-01

    Hand burns represent a unique challenge to the burns team due to the intricate structure and unrivalled functional importance of the hand. The initial assessment and prognosis relies on consideration of the specific site involved as well as depth of the burn. We created a simple severity score that could be used by referring non-specialists and researchers alike. The Hand Burn Severity (HABS) score stratifies hand burns according to severity with a numerical value of between 0 (no burn) and 18 (most severe) per hand. Three independent assessors scored the photographs of 121 burned hands of 106 adult and paediatric patients, demonstrating excellent inter-rater reliability (r=0.91, p<0.0001 on testing with Lin's correlation coefficient). A significant relationship was shown between the HABS score and a reliable binary outcome of the requirement for surgical excision on Mann-Whitney U testing (U=152; Z=9.8; p=0.0001). A receiver operator characteristic (ROC) curve analysis found a cut off score of 5.5, indicating that those with a HABS score below 6 did not require an operation, whereas those with a score above 6 did. The HABS score was shown to be more sensitive and specific that assessment of burn depth alone. The HABS score is a simple to use tool to stratify severity at initial presentation of hand burns which will be useful when referring, and when reporting outcomes. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  15. Measurement of hand dynamics in a microsurgery environment: Preliminary data in the design of a bimanual telemicro-operation test bed

    NASA Technical Reports Server (NTRS)

    Charles, Steve; Williams, Roy

    1989-01-01

    Data describing the microsurgeon's hand dynamics was recorded and analyzed in order to provide an accurate model for the telemicrosurgery application of the Bimanual Telemicro-operation Test Bed. The model, in turn, will guide the development of algorithms for the control of robotic systems in bimanual telemicro-operation tasks. Measurements were made at the hand-tool interface and include position, acceleration and force between the tool-finger interface. Position information was captured using an orthogonal pulsed magnetic field positioning system resulting in measurements in all six degrees-of-freedom (DOF). Acceleration data at the hands was obtained using accelerometers positioned in a triaxial arrangement on the back of the hand allowing measurements in all three cartesian-coordinate axes. Force data was obtained by using miniature load cells positioned between the tool and the finger and included those forces experienced perpendicular to the tool shaft and those transferred from the tool-tissue site. Position data will provide a minimum/maximum reference frame for the robotic system's work space or envelope. Acceleration data will define the response times needed by the robotic system in order to emulate and subsequently outperform the human operator's tool movements. The force measurements will aid in designing a force-reflective, force-scaling system as well as defining the range of forces the robotic system will encounter. All analog data was acquired by a 16-channel analog-to-digital conversion system residing in a IBM PC/AT-compatible computer at the Center's laboratory. The same system was also used to analyze and present the data.

  16. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    NASA Astrophysics Data System (ADS)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  17. Clean and Green: Saving Water in the Operating Theatre

    PubMed Central

    Jehle, Karlheinz; Jarrett, Nick; Matthews, Shaun

    2008-01-01

    INTRODUCTION There is a growing trend to use alcohol-based hand disinfectants in clinical practice. In addition to their antibacterial efficacy, these disinfectants offer an alternative to traditional surgical hand disinfection agents that can save water in the operating theatre. MATERIALS AND METHODS The amounts of water and soap used during traditional surgical hand disinfection with antiseptic soap preparations were measured and water usage over a 1-year period was estimated. Costs of traditional disinfection agents were compared with alcohol-based agents. RESULTS One surgical hand disinfection episode with traditional agents used 18.5 l of water. During 15,500 procedures performed at our institution over a 1-year period, 931,938 l of water were used which could have been saved had alcohol-based agents been used. Cost per episode of hand disinfection depends on the amounts used and is not higher compared to traditional agents. CONCLUSIONS The benefits of using an alcohol-based surgical hand disinfectant may include significant water savings, in addition to previously published advantages of improved efficacy. When deciding on the method of surgical hand disinfection, careful thought should be given to the use of water as a resource. Surgeons should be aware of the environmental impact of their profession. PMID:18201493

  18. THE INFLUENCE OF VARIABLE ELIMINATION RATE AND BODY FAT MASS IN A PBPK MODEL FOR TCDD IN PREDICTING THE SERUM TCDD CONCENTRATIONS FROM VETERANS OF OPERATION RANCH HAND

    EPA Science Inventory

    The Influence of Variable Elimination Rate and Body Fat Mass in a PBPK Model for TCDD in Predicting the Serum TCDD Concentrations from Veterans of Operation Ranch Hand.
    C Emond1,2, LS Birnbaum2, JE Michalek3, MJ DeVito2
    1 National Research Council, National Academy of Scien...

  19. Life-style factors and hand eczema.

    PubMed

    Anveden Berglind, I; Alderling, M; Meding, B

    2011-09-01

    Previous knowledge of the impact of certain life-style factors on hand eczema is scanty. To investigate a possible association between hand eczema and life-style factors such as obesity, physical exercise, stress, smoking and alcohol consumption. In a cross-sectional public health survey in Stockholm, Sweden, 27,994 (58%) randomly chosen individuals aged 18-64 years completed a postal questionnaire regarding physical and mental health, social relations, economic status and work. Of these, 27,793 individuals responded to the question regarding hand eczema and were included in the present study. The association between life-style factors and hand eczema was analysed by prevalence proportion ratios (PPR), using a generalized linear model. Hand eczema was more common among individuals who reported high stress levels, PPR 1·326 (95% CI 1·303-1·350). There was also a positive dose-response relationship between hand eczema and stress. Hand eczema was less common among individuals reporting high physical exercise, and most apparent in women, PPR 0·781 (95% CI 0·770-0·792). Men who reported high alcohol intake reported hand eczema less often, PPR 0·958 (95% CI 0·930-0·987). Obese individuals reported hand eczema more commonly, PPR 1·204 (95% CI 1·174-1·234). There was a slight increase of hand eczema among smokers, PPR 1·025 (95% CI 1·006-1·044). Hand eczema was more common in individuals who reported stress, obesity and smoking. In individuals who reported high physical exercise levels hand eczema was less common. As there appears to be an association between life-style factors and hand eczema it is important to consider life-style factors in clinical practice. © 2011 The Authors. BJD © 2011 British Association of Dermatologists.

  20. Photon spectrum and absorbed dose in brain tumor.

    PubMed

    Vega-Carrillo, Hector Rene; Silva-Sanchez, Angeles; Rivera-Montalvo, Teodoro

    2016-11-01

    Using Monte Carlo methods a BOMAB phantom inside a treatment hall with a brain tumor nearby the pituitary gland was treated with photons produced by a Varian 6MV linac. The photon spectrum and the absorbed dose were calculated in the tumor, pituitary gland and the head. The treatment beam was collimated to illuminate only the tumor volume; however photons were noticed in the gland. Photon fluence reaching the tumor is and 15.7 times larger than the fluence in the pituitary gland, on the other hand the absorbed dose in the tumor is 37.1 times larger than the dose in the gland because photons that reach the pituitary gland are scattered, by the head and the tumor, through Compton effect. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Orchid flowers tolerance to gamma-radiation

    NASA Astrophysics Data System (ADS)

    Kikuchi, Olivia Kimiko

    2000-03-01

    Cut flowers are fresh goods that may be treated with fumigants such as methyl bromide to meet the needs of the quarantine requirements of importing countries. Irradiation is a non-chemical alternative to substitute the methyl bromide treatment of fresh products. In this research, different cut orchids were irradiated to examine their tolerance to gamma-rays. A 200 Gy dose did inhibit the Dendrobium palenopsis buds from opening, but did not cause visible damage to opened flowers. Doses of 800 and 1000 Gy were damaging because they provoked the flowers to drop from the stem. Cattleya irradiated with 750 Gy did not show any damage, and were therefore eligible for the radiation treatment. Cymbidium tolerated up to 300 Gy and above this dose dropped prematurely. On the other hand, Oncydium did not tolerate doses above 150 Gy.

  2. Rapid Acute Dose Assessment Using MCNP6

    NASA Astrophysics Data System (ADS)

    Owens, Andrew Steven

    Acute radiation doses due to physical contact with a high-activity radioactive source have proven to be an occupational hazard. Multiple radiation injuries have been reported due to manipulating a radioactive source with bare hands or by placing a radioactive source inside a shirt or pants pocket. An effort to reconstruct the radiation dose must be performed to properly assess and medically manage the potential biological effects from such doses. Using the reference computational phantoms defined by the International Commission on Radiological Protection (ICRP) and the Monte Carlo N-Particle transport code (MCNP6), dose rate coefficients are calculated to assess doses for common acute doses due to beta and photon radiation sources. The research investigates doses due to having a radioactive source in either a breast pocket or pants back pocket. The dose rate coefficients are calculated for discrete energies and can be used to interpolate for any given energy of photon or beta emission. The dose rate coefficients allow for quick calculation of whole-body dose, organ dose, and/or skin dose if the source, activity, and time of exposure are known. Doses are calculated with the dose rate coefficients and compared to results from the International Atomic Energy Agency (IAEA) reports from accidents that occurred in Gilan, Iran and Yanango, Peru. Skin and organ doses calculated with the dose rate coefficients appear to agree, but there is a large discrepancy when comparing whole-body doses assessed using biodosimetry and whole-body doses assessed using the dose rate coefficients.

  3. Combined Use of a Patient Dose Monitoring System and a Real-Time Occupational Dose Monitoring System for Fluoroscopically Guided Interventions.

    PubMed

    Heilmaier, Christina; Kara, Levent; Zuber, Niklaus; Berthold, Christian; Weishaupt, Dominik

    2016-04-01

    To determine the effect on patient radiation exposure of the combined use of a patient dose monitoring system and real-time occupational dose monitoring during fluoroscopically guided interventions (FGIs). Patient radiation exposure, in terms of the kerma area product (KAP; Gy ∙ cm(2)), was measured in period 1 with a patient dose monitoring system, and a real-time occupational dose monitoring system was additionally applied in period 2. Mean/median KAP in 19 different types of FGIs was analyzed in both periods for two experienced interventional radiologists combined as well as individually. Patient dose and occupational dose were correlated, applying Pearson and Spearman correlation coefficients. Although FGIs were similar in numbers and types over both periods, a substantial decrease was found for period 2 in total mean ± SD/median KAP for both operators together (period 1, 47 Gy ∙ cm(2) ± 67/41 Gy ∙ cm(2); period 2, 37 Gy ∙ cm(2) ± 69/34 Gy ∙ cm(2)) as well as for each individual operator (for all, P < .05). Overall, KAP declined considerably in 15 of 19 types of FGIs in period 2. Mean accumulated dose per intervention was 4.6 µSv, and mean dose rate was 0.24 mSv/h. There was a strong positive correlation between patient and occupational dose (r = 0.88). Combined use of a patient dose monitoring system and a real-time occupational dose monitoring system in FGIs significantly lessens patient and operator doses. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  4. Radiation exposure in interventional radiology

    NASA Astrophysics Data System (ADS)

    Pinto, N. G. V.; Braz, D.; Vallim, M. A.; Filho, L. G. P.; Azevedo, F. S.; Barroso, R. C.; Lopes, R. T.

    2007-09-01

    The aim of this study is to evaluate dose values in patients and staff involved in some interventional radiology procedures. Doses have been measured using thermoluminescent dosemeters for single procedures (such as renal and cerebral arteriography, transjungular intrahepatic portasystemic shunt (TIPS) and chemoembolization). The magnitude of doses through the hands of interventional radiologists has been studied. Dose levels were evaluated in three points for patients (eye, thyroid and gonads). The dose-area product (DAP) was also investigated using a Diamentor (PTW-M2). The dose in extremities was estimated for a professional who generally performed one TIPS, two chemoembolizations, two cerebral arteriographies and two renal arteriographies in a week. The estimated annual radiation dose was converted to effective dose as suggested by the 453-MS/Brazil norm The annual dose values were 137.25 mSv for doctors, 40.27 mSv for nurses and 51.95 mSv for auxiliary doctors, and all these annual dose values are below the limit established. The maximum values of the dose obtained for patients were 6.91, 10.92 and 15.34 mGy close to eye, thyroid and gonads, respectively. The DAP values were evaluated for patients in the same interventional radiology procedures. The dose and DAP values obtained are in agreement with values encountered in the literature.

  5. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CODING AND CODING VERIFICATION (HAND ENTRY) (UA-D-14.0)

    EPA Science Inventory

    The purpose of this SOP is to define the coding strategy for coding and coding verification of hand-entered data. It applies to the coding of all physical forms, especially those coded by hand. The strategy was developed for use in the Arizona NHEXAS project and the "Border" st...

  6. Fixture for winding transformers

    NASA Technical Reports Server (NTRS)

    Mclyman, M. T.

    1980-01-01

    Bench-mounted fixture assists operator in winding toroid-shaped transformer cores. Toroid is rigidly held in place as wires are looped around. Arrangement frees both hands for rapid winding and untangling of wires that occurs when core is hand held.

  7. Rotationally Actuated Prosthetic Hand

    NASA Technical Reports Server (NTRS)

    Norton, William E.; Belcher, Jewell G., Jr.; Carden, James R.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand attached to end of remaining part of forearm and to upper arm just above elbow. Pincerlike fingers pushed apart to degree depending on rotation of forearm. Simpler in design, simpler to operate, weighs less, and takes up less space.

  8. Design of a force reflecting hand controller for space telemanipulation studies

    NASA Technical Reports Server (NTRS)

    Paines, J. D. B.

    1987-01-01

    The potential importance of space telemanipulator systems is reviewed, along with past studies of master-slave manipulation using a generalized force reflecting master arm. Problems concerning their dynamic interaction with the human operator have been revealed in the use of these systems, with marked differences between 1-g and simulated weightless conditions. A study is outlined to investigate the optimization of the man machine dynamics of master-slave manipulation, and a set of specifications is determined for the apparatus necessary to perform this investigation. This apparatus is a one degree of freedom force reflecting hand controller with closed loop servo control which enables it to simulate arbitrary dynamic properties to high bandwidth. Design of the complete system and its performance is discussed. Finally, the experimental adjustment of the hand controller dynamics for smooth manual control performance with good operator force perception is described, resulting in low inertia, viscously damped hand controller dynamics.

  9. [Hand-arm vibration syndrome in a nurse carrying out gypsum cutting operations].

    PubMed

    Speziale, Martina; Picchiotti, E

    2009-01-01

    A professional nurse, employed mainly on gypsum cutting operations, developed a hand-arm vibration syndrome with Raynaud's phenomenon, neurosensitive disorders and impairment of the bone and joints apparatus of the hand and arm. The nurse underwent diagnostic investigations (cold test, X-ray of the upper limbs, blood tests); also the vibration levels transmitted from instrument were measured and the exposure times were established. Clinical investigations showed the presence of a hand-arm vibration syndrome with secondary Raynaud's phenomenon and environmental surveys revealed very high vibration levels, such as could be associated with the disease with a causal relationship. In the literature no reports exist of the vibration syndrome being associated with health care workers in orthopaedic departments. The case described in this study occurred because of peculiar organisational factors that most likely have never occurred in other hospitals or orthopaedic departments.

  10. Effects of a new glucocorticoid, oxazacort, on some variables connected with bone metabolism in man: a comparison with prednisone.

    PubMed

    Caniggia, A; Marchetti, M; Gennari, C; Vattimo, A; Nicolis, F B

    1977-03-01

    The urinary elimination of calcium, other electrolytes, and hydroxyproline and the oral absorption of 47Ca have been evaluated in three groups of 8 patients before and during a 15-day treatment with prednisone at daily doses of 25 and 50 mg and with oxazacort, a new glucocorticoid, at a daily dose of 50 mg. The results obtained demonstrate that oxazacort in short-term teatment with a high dose has no significant effect on the urinary elimination of calcium and hydroxypyroline in experimental conditions in which prednisone produces statistically significant and clinically relevant increase, both when given at the same dose and when given at half that dose. On the other hand, the oral absorption of 47Ca is decreased by oxazacort, but less than by prednisone at the same dose. As the antirheumatic activity of oxazacort appears to be only slightly lower than that of prednisone (activity ratio of about 0.84: 1), these findings may have interesting therapeutic implications.

  11. Radiation dose of nurses during IR procedures: a controlled trial evaluating operator alerts before nursing tasks.

    PubMed

    Komemushi, Atsushi; Suzuki, Satoshi; Sano, Akira; Kanno, Shohei; Kariya, Shuji; Nakatani, Miyuki; Yoshida, Rie; Kono, Yumiko; Ikeda, Koshi; Utsunomiya, Keita; Harima, Yoko; Komemushi, Sadao; Tanigawa, Noboru

    2014-08-01

    To compare radiation exposure of nurses when performing nursing tasks associated with interventional procedures depending on whether or not the nurses called out to the operator before approaching the patient. In a prospective study, 93 interventional radiology procedures were randomly divided into a call group and a no-call group; there were 50 procedures in the call group and 43 procedures in the no-call group. Two monitoring badges were used to calculate effective dose of nurses. In the call group, the nurse first told the operator she was going to approach the patient each time she was about to do so. In the no-call group, the nurse did not say anything to the operator when she was about to approach the patient. In all the nursing tasks, the equivalent dose at the umbilical level inside the lead apron was below the detectable limit. The equivalent dose at the sternal level outside the lead apron was 0.16 μSv ± 0.41 per procedure in the call group and 0.51 μSv ± 1.17 per procedure in the no-call group. The effective dose was 0.018 μSv ± 0.04 per procedure in the call group and 0.056 μSv ± 0.129 per procedure in the no-call group. The call group had a significantly lower radiation dose (P = .034). Radiation doses of nurses were lower in the group in which the nurse called to the operator before she approached the patient. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less

  13. 68. Credit FM. Detail showing operators. Note cooling duct (now ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    68. Credit FM. Detail showing operators. Note cooling duct (now removed), governor (now removed), hand-operated needle valve controls (now removed). - Battle Creek Hydroelectric System, Battle Creek & Tributaries, Red Bluff, Tehama County, CA

  14. Accuracy of micro powder dosing via a vibratory sieve-chute system.

    PubMed

    Besenhard, M O; Faulhammer, E; Fathollahi, S; Reif, G; Calzolari, V; Biserni, S; Ferrari, A; Lawrence, S M; Llusa, M; Khinast, J G

    2015-08-01

    This paper describes a powder dosing system with a vibratory sieve mounted on a chute that doses particles into a capsule. Vertical vibration occurred with a broad range of frequencies and amplitudes. During dosing events, the fill weight was accurately recorded via a capacitance sensor, covering the capsules and making it possible to analyze filling characteristics, that is, the fill rates and their robustness. The range of frequencies and amplitudes was screened for settings that facilitated reasonable (no blocking, no spilling) fill rates for three lactose powders. The filling characteristics were studied within this operating space. The results reveal similar operating spaces for all investigated powders. The fill rate robustness varied distinctly in the operating space, which is of prime importance for selecting the settings for continuous feeding applications. In addition, we present accurate dosing studies utilizing the knowledge about the filling characteristics of each powder. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Potential third-party radiation exposure from outpatients treated with {sup 131}I for hyperthyroidism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matheoud, Roberta; Reschini, Eugenio; Canzi, Cristina

    2004-12-01

    Thirty-three hyperthyroid patients treated with radioiodine (mean administered activity 414 MBq, range 163-555) were studied to determine if pretreatment dosimetry could be used to give radiation protection advice that could assure compliance with the effective dose constraints suggested by the European Commission. Effective doses to travelers, co-workers, and sleeping partners were estimated by integrating the effective dose rate-versus-time curve obtained by fitting the dose rates measured several times after radioiodine administration to a biexponential function. The mean estimated effective doses to travelers, co-workers, and sleeping partners were 0.11 mSv (0.05-0.24), 0.24 mSv (0.07-0.52), and 1.8 mSv (0.6-4.1), respectively. The bestmore » correlation was found between effective dose (D) in mSv and maximum activity (AU{sub max}) in MBq taken up in the thyroid: D{sub traveler}=0.0005*(AU{sub max})+0.04 (r=0.88,p<0.01); D{sub co-worker}=0.0013*(AU{sub max})+0.03(r=0.89,p<0.01); D{sub sleepingpartners}=0.0105*(AU{sub max})+0.16 (r=0.93,p<0.01). Private/public transports are always allowed. For the co-workers the effective dose constraint of 0.3 mSv is met without restrictions and with 3 days off work if AU{sub max} is lower or higher than 185 MBq, respectively. For the sleeping partners the effective dose constraint of 3 mSv is met without restriction and with 4 nights separate sleeping arrangements if AU{sub max} is lower or higher than 185 MBq, respectively. The potential for contamination by the patients was determined from perspiration samples taken from the patient's hands, forehead, and neck and in saliva at 4, 24, and 48 h after radioiodine treatment. The mean highest {sup 131}I activity levels for hands, forehead, neck, and saliva were 4.1 Bq/cm{sup 2}, 1.9 Bq/cm{sup 2}, 0.9 Bq/cm{sup 2}, and 796 kBq/g, respectively. The results indicate that there is minimal risk of contamination from these patients.« less

  16. Micro-dose hCG as luteal phase support without exogenous progesterone administration: mathematical modelling of the hCG concentration in circulation and initial clinical experience.

    PubMed

    Andersen, C Yding; Fischer, R; Giorgione, V; Kelsey, Thomas W

    2016-10-01

    For the last two decades, exogenous progesterone administration has been used as luteal phase support (LPS) in connection with controlled ovarian stimulation combined with use of the human chorionic gonadotropin (hCG) trigger for the final maturation of follicles. The introduction of the GnRHa trigger to induce ovulation showed that exogenous progesterone administration without hCG supplementation was insufficient to obtain satisfactory pregnancy rates. This has prompted development of alternative strategies for LPS. Augmenting the local endogenous production of progesterone by the multiple corpora lutea has been one focus with emphasis on one hand to avoid development of ovarian hyper-stimulation syndrome and, on the other hand, to provide adequate levels of progesterone to sustain implantation. The present study evaluates the use of micro-dose hCG for LPS support and examines the potential advances and disadvantages. Based on the pharmacokinetic characteristics of hCG, the mathematical modelling of the concentration profiles of hCG during the luteal phase has been evaluated in connection with several different approaches for hCG administration as LPS. It is suggested that the currently employed LPS provided in connection with the GnRHa trigger (i.e. 1.500 IU) is too strong, and that daily micro-dose hCG administration is likely to provide an optimised LPS with the current available drugs. Initial clinical results with the micro-dose hCG approach are presented.

  17. Extra-oral dental radiography for disaster victims using a flat panel X-ray detector and a hand-held X-ray generator.

    PubMed

    Ohtani, M; Oshima, T; Mimasaka, S

    2017-12-01

    Forensic odontologists commonly incise the skin for post-mortem dental examinations when it is difficult to open the victim's mouth. However, it is prohibited by law to incise dead bodies without permission in Japan. Therefore, we attempted using extra-oral dental radiography, using a digital X-ray equipment with rechargeable batteries, to overcome this restriction. A phantom was placed in the prone position on a table, and three plain dental radiographs were used per case: "lateral oblique radiographs" for left and right posterior teeth and a "contact radiograph" for anterior teeth were taken using a flat panel X-ray detector and a hand-held X-ray generator. The resolving power of the images was measured by a resolution test chart, and the scattered X-ray dose was measured using an ionization chamber-type survey meter. The resolving power of the flat panel X-ray detector was 3.0 lp/mm, which was less than that of intra-oral dental methods, but the three extra-oral plain dental radiographs provided the overall dental information from outside of the mouth, and this approach was less time-consuming. In addition, the higher dose of scattered X-rays was laterally distributed, but the dose per case was much less than that of intra-oral dental radiographs. Extra-oral plain dental radiography can be used for disaster victim identification by dental methods even when it is difficult to open the mouth. Portable and rechargeable devices, such as a flat panel X-ray detector and a hand-held X-ray generator, are convenient to bring and use anywhere, even at a disaster scene lacking electricity and water.

  18. Portable Computer Keyboard For Use With One Hand

    NASA Technical Reports Server (NTRS)

    Friedman, Gary L.

    1992-01-01

    Data-entry device held in one hand and operated with five fingers. Contains seven keys. Letters, numbers, punctuation, and cursor commands keyed into computer by pressing keys in various combinations. Device called "data egg" used where standard typewriter keyboard unusable or unavailable. Contains micro-processor and 32-Kbyte memory. Captures text and transmits it to computer. Concept extended to computer mouse. Especially useful to handicapped or bedridden people who find it difficult or impossible to operate standard keyboards.

  19. Particular bi-fuel application of spark ignition engines

    NASA Astrophysics Data System (ADS)

    Raţiu, S.; Alexa, V.; Kiss, I.

    2016-02-01

    This paper presents a comparative test concerning the operation of a spark-ignition engine, make: Dacia 1300, model: 810.99, fuelled alternatively with gasoline and LPG (Liquefied Petroleum Gas). The tests carried out show, on the one hand, the maintenance of power and torque performances in both engine fuelling cases, for all the engine operation regimes, and, on the other hand, a considerable decrease in CO and HC emissions when using poor mixtures related to LPG fuelling.

  20. [Integrate the surgical hand disinfection as a quality indicator in an operating room of urology].

    PubMed

    Francois, M; Girard, R; Mauranne, C C; Ruffion, A; Terrier, J E

    2017-12-01

    The surgical hand disinfection by friction (SDF) helps to reduce the risk of surgical site infections. For this purpose and in order to promote good compliance to quality care, the urology service of Centre Hospitalier Lyon Sud achieved a continuous internal audit to improve the quality of the SDF. An internal audit executed by the medical students of urology was established in 2013. The study population was all operators, instrumentalists and operating aids of urology operating room (OR). Each student realized 5-10 random observations, of all types of professionals. The criteria measured by the audit were criteria for friction. The evolution of indicators was positive. Particularly, the increasing duration of the first and second friction was statistically significant during follow-up (P=0.001). The total duration of friction shows a similar trend for all professionals. The surgical hand disinfection by friction in the urology OR of the Centre Hospitalier Lyon Sud has gradually improved over the iterative audits. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Decontamination in a Russian settlement.

    PubMed

    Fogh, C L; Andersson, K G; Barkovsky, A N; Mishine, A S; Ponamarjov, A V; Ramzaev, V P; Roed, J

    1999-04-01

    Decontamination was carried out in an area with three houses in Novo Bobovichi, Bryansk region, Russia, in the autumn of 1995. It was demonstrated that significant reductions in the dose rate both indoor (DRF = 0.34) and outdoor (DRF = 0.20) can be achieved when a controlled cleaning is undertaken. This paper describes the decontamination work carried out and the results obtained. The roofs of the houses were swept and cleaned by special roof cleaning equipment. The soil around the houses was removed by hand while carefully monitoring the ground for residual contamination. By monitoring the decline in the dose rate during the different stages of the work the dose reducing effect of each action has been measured.

  2. Sensor-based fine telemanipulation for space robotics

    NASA Technical Reports Server (NTRS)

    Andrenucci, M.; Bergamasco, M.; Dario, P.

    1989-01-01

    The control of a multifingered hand slave in order to accurately exert arbitrary forces and impart small movements to a grasped object is, at present, a knotty problem in teleoperation. Although a number of articulated robotic hands have been proposed in the recent past for dexterous manipulation in autonomous robots, the possible use of such hands as slaves in teleoperated manipulation is hindered by the present lack of sensors in those hands, and (even if those sensors were available) by the inherent difficulty of transmitting to the master operator the complex sensations elicited by such sensors at the slave level. An analysis of different problems related to sensor-based telemanipulation is presented. The general sensory systems requirements for dexterous slave manipulators are pointed out and the description of a practical sensory system set-up for the developed robotic system is presented. The problem of feeding back to the human master operator stimuli that can be interpreted by his central nervous system as originated during real dexterous manipulation is then considered. Finally, some preliminary work aimed at developing an instrumented glove designed purposely for commanding the master operation and incorporating Kevlar tendons and tension sensors, is discussed.

  3. Artificial dexterous hand

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan (Inventor)

    1990-01-01

    An artificial dexterous hand is provided for grasping and manipulating objects. The hand includes left and right thumbs that are operatively connected to an engagement assembly which causes movement of the left and right thumbs. The left thumb has a left thumb base and is movable about three separate first left thumb axes which run through the left thumb base. Correspondingly, the right thumb has a right thumb base and is movable about three separate first right thumb axes which run through the right thumb base. The engagement assembly has a gear assembly which is operatively connected to a motor assembly. Upon actuation by the motor assembly, the gear assembly causes movement of the left and right thumbs about the first left thumb axes and first right thumb axes respectively. The hand can also have a center finger which is operatively connected to the engagement assembly and which is interposed between the left and right thumbs. The finger has a finger base and is movable about two separate first finger axes running through the finger base. Therefore, upon actuation by the motor assembly, the gear assembly will also cause movement of the finger about the first finger axes.

  4. Association between use of hand hygiene products and rates of health care-associated infections in a large university hospital in Norway.

    PubMed

    Herud, Trine; Nilsen, Roy M; Svendheim, Kjersti; Harthug, Stig

    2009-05-01

    An association between use of hand hygiene products and health care-associated infection rates was investigated in a large Norwegian university hospital. We conducted an ecologic study by combining data from purchasing and admission systems with data from 32 point prevalence surveys (27,248 patients) in 1998-2005. Data on purchase of hand disinfectants and soap, and patient-days, were collected for 20 bed wards similar to those of the prevalence surveys. The prevalence of infections was 7.1%. We found no significant decline in overall infections (P = .19), but use of hand hygiene products significantly increased from 28.5 L per 1000 patients-days in 1998 to 43.3 L per 1000 patient-days in 2005 (P < .001). After examining a linear dose-response relation between use and infection rates, we observed a borderline significant decline in infections from 8% to 6% with increased use of hand hygiene products (P = .05). This association appeared stronger for wards that were registered with infections >9% at study start in 1998 (P < .001). These data suggests that infection rates may be reflected by amount of hand hygiene products used. Quantification of such products over time may serve as an indicator for hand hygiene performance in hospitals.

  5. Nitric oxide mediates the anticonvulsant effects of thalidomide on pentylenetetrazole-induced clonic seizures in mice.

    PubMed

    Payandemehr, Borna; Rahimian, Reza; Gooshe, Maziar; Bahremand, Arash; Gholizadeh, Ramtin; Berijani, Sina; Ahmadi-Dastgerdi, Mohammad; Aminizade, Mehdi; Sarreshte-Dari, Ali; Dianati, Vahid; Amanlou, Massoud; Dehpour, Ahmad Reza

    2014-05-01

    Thalidomide is an old glutamic acid derivative which was initially used as a sedative medication but withdrawn from the market due to the high incidence of teratogenicity. Recently, it has reemerged because of its potential for counteracting number of diseases, including neurodegenerative disorders. Other than the antiemetic and hypnotic aspects, thalidomide exerts some anticonvulsant properties in experimental settings. However, the underlying mechanisms of thalidomide actions are not fully realized yet. Some investigations revealed that thalidomide could elicit immunomodulatory or neuromodulatory properties by affecting different targets, including cytokines (such as TNF α), neurotransmitters, and nitric oxide (NO). In this regard, we used a model of clonic seizure induced by pentylenetetrazole (PTZ) in male NMRI mice to investigate whether the anticonvulsant effect of thalidomide is affected through modulation of the l-arginine-nitric oxide pathway or not. Injection of a single effective dose of thalidomide (10 mg/kg, i.p. or higher) significantly increased the seizure threshold (P<0.05). On the one hand, pretreatment with low and per se noneffective dose of l-arginine [NO precursor] (10, 30 and 60 mg/kg) prevented the anticonvulsant effect of thalidomide. On the other hand, NOS inhibitors [l-NAME and 7-NI] augmented the anticonvulsant effect of a subeffective dose of thalidomide (1 and 5 mg/kg, i.p.) at relatively low doses. Meanwhile, several doses of aminoguanidine [an inducible NOS inhibitor] (20, 50 and 100 mg/kg) failed to alter the anticonvulsant effect of thalidomide significantly. In summary, our findings demonstrated that the l-arginine-nitric oxide pathway can be involved in the anticonvulsant properties of thalidomide, and the role of constitutive nNOS is prominent in the reported neuroprotective feature. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Integration of Functional Magnetic Resonance Imaging and Magnetoencephalography Functional Maps Into a CyberKnife Planning System: Feasibility Study for Motor Activity Localization and Dose Planning.

    PubMed

    De Martin, Elena; Duran, Dunja; Ghielmetti, Francesco; Visani, Elisa; Aquino, Domenico; Marchetti, Marcello; Sebastiano, Davide Rossi; Cusumano, Davide; Bruzzone, Maria Grazia; Panzica, Ferruccio; Fariselli, Laura

    2017-12-01

    Magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI) provide noninvasive localization of eloquent brain areas for presurgical planning. The aim of this study is the integration of MEG and fMRI maps into a CyberKnife (CK) system to optimize dose planning. Four patients with brain metastases in the motor area underwent functional imaging study of the hand motor cortex before radiosurgery. MEG data were acquired during a visually cued hand motor task. Motor activations were identified also using an fMRI block-designed paradigm. MEG and fMRI maps were then integrated into a CK system and contoured as organs at risk for treatment planning optimization. The integration of fMRI data into the CK system was achieved for all patients by means of a standardized protocol. We also implemented an ad hoc pipeline to convert the MEG signal into a DICOM standard, to make sure that it was readable by our CK treatment planning system. Inclusion of the activation areas into the optimization plan allowed the creation of treatment plans that reduced the irradiation of the motor cortex yet not affecting the brain peripheral dose. The availability of advanced neuroimaging techniques is playing an increasingly important role in radiosurgical planning strategy. We successfully imported MEG and fMRI activations into a CK system. This additional information can improve dose sparing of eloquent areas, allowing a more comprehensive investigation of the related dose-volume constraints that in theory could translate into a gain in tumor local control, and a reduction of neurological complications. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Estimation of staff lens doses during interventional procedures. Comparing cardiology, neuroradiology and interventional radiology.

    PubMed

    Vano, E; Sanchez, R M; Fernandez, J M

    2015-07-01

    The purpose of this article is to estimate lens doses using over apron active personal dosemeters in interventional catheterisation laboratories (cardiology IC, neuroradiology IN and radiology IR) and to investigate correlations between occupational lens doses and patient doses. Active electronic personal dosemeters placed over the lead apron were used on a sample of 204 IC procedures, 274 IN and 220 IR (all performed at the same university hospital). Patient dose values (kerma area product) were also recorded to evaluate correlations with occupational doses. Operators used the ceiling-suspended screen in most cases. The median and third quartile values of equivalent dose Hp(10) per procedure measured over the apron for IC, IN and IR resulted, respectively, in 21/67, 19/44 and 24/54 µSv. Patient dose values (median/third quartile) were 75/128, 83/176 and 61/159 Gy cm(2), respectively. The median ratios for dosemeters worn over the apron by operators (protected by the ceiling-suspended screen) and patient doses were 0.36; 0.21 and 0.46 µSv Gy(-1) cm(-2), respectively. With the conservative approach used (lens doses estimated from the over apron chest dosemeter) we came to the conclusion that more than 800 procedures y(-1) and per operator were necessary to reach the new lens dose limit for the three interventional specialties. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Anthropomorphic Telemanipulation System in Terminus Control Mode

    NASA Technical Reports Server (NTRS)

    Jau, Bruno M.; Lewis, M. Anthony; Bejczy, Antal K.

    1994-01-01

    This paper describes a prototype anthropomorphic kinesthetic telepresence system that is being developed at JPL. It utilizes dexterous terminus devices in the form of an exoskeleton force-sensing master glove worn by the operator and a replica four finger anthropomorphic slave hand. The newly developed master glove is integrated with our previously developed non-anthropomorphic six degree of freedom (DOF) universal force-reflecting hand controller (FRHC). The mechanical hand and forearm are mounted to an industrial robot (PUMA 560), replacing its standard forearm. The notion of 'terminus control mode' refers to the fact that only the terminus devices (glove and robot hand) are of anthropomorphic nature, and the master and slave arms are non-anthropomorphic. The system is currently being evaluated, focusing on tool handling and astronaut equivalent task executions. The evaluation revealed the system's potential for tool handling but it also became evident that hand tool manipulations and space operations require a dual arm robot. This paper describes the system's principal components, its control and computing architecture, discusses findings of the tool handling evaluation, and explains why common tool handling and EVA space tasks require dual arm robots.

  9. Feasibility study into self-administered training at home using an arm and hand device with motivational gaming environment in chronic stroke.

    PubMed

    Nijenhuis, Sharon M; Prange, Gerdienke B; Amirabdollahian, Farshid; Sale, Patrizio; Infarinato, Francesco; Nasr, Nasrin; Mountain, Gail; Hermens, Hermie J; Stienen, Arno H A; Buurke, Jaap H; Rietman, Johan S

    2015-10-09

    Assistive and robotic training devices are increasingly used for rehabilitation of the hemiparetic arm after stroke, although applications for the wrist and hand are trailing behind. Furthermore, applying a training device in domestic settings may enable an increased training dose of functional arm and hand training. The objective of this study was to assess the feasibility and potential clinical changes associated with a technology-supported arm and hand training system at home for patients with chronic stroke. A dynamic wrist and hand orthosis was combined with a remotely monitored user interface with motivational gaming environment for self-administered training at home. Twenty-four chronic stroke patients with impaired arm/hand function were recruited to use the training system at home for six weeks. Evaluation of feasibility involved training duration, usability and motivation. Clinical outcomes on arm/hand function, activity and participation were assessed before and after six weeks of training and at two-month follow-up. Mean System Usability Scale score was 69 % (SD 17 %), mean Intrinsic Motivation Inventory score was 5.2 (SD 0.9) points, and mean training duration per week was 105 (SD 66) minutes. Median Fugl-Meyer score improved from 37 (IQR 30) pre-training to 41 (IQR 32) post-training and was sustained at two-month follow-up (40 (IQR 32)). The Stroke Impact Scale improved from 56.3 (SD 13.2) pre-training to 60.0 (SD 13.9) post-training, with a trend at follow-up (59.8 (SD 15.2)). No significant improvements were found on the Action Research Arm Test and Motor Activity Log. Remotely monitored post-stroke training at home applying gaming exercises while physically supporting the wrist and hand showed to be feasible: participants were able and motivated to use the training system independently at home. Usability shows potential, although several usability issues need further attention. Upper extremity function and quality of life improved after training, although dexterity did not. These findings indicate that home-based arm and hand training with physical support from a dynamic orthosis is a feasible tool to enable self-administered practice at home. Such an approach enables practice without dependence on therapist availability, allowing an increase in training dose with respect to treatment in supervised settings. This study has been registered at the Netherlands Trial Registry (NTR): NTR3669 .

  10. Perineal injury associated with hands on/hands poised and directed/undirected pushing: A retrospective cross-sectional study of non-operative vaginal births, 2011-2016.

    PubMed

    Lee, Nigel; Firmin, Meaghan; Gao, Yu; Kildea, Sue

    2018-07-01

    Clinicians hand position and advised pushing techniques may impact on rates of perineal injury. To assess the association of four techniques used in management of second stage with risk of moderate and severe perineal injury. Retrospective cross-sectional study. A metropolitan maternity hospital and a private maternity hospital in Brisbane, Australia. Term women with singleton, cephalic presentation experiencing a non-operative vaginal birth from January 2011 to December 2016. The research sites perinatal database recorded data on clinicians approach to instructing women during second stage and hand position at birth. Women were identified from matching the inclusion criteria (n = 26,393) then grouped based on combinations of hands-on, hand- poised, directed and undirected pushing. The associations with perineal injury were estimated using odds ratios obtained by multivariate analysis. Primary outcomes were the risk of moderate and severe perineal injury. The significance was set at 0.001. In Nulliparous women there was no difference in the risk of moderate or severe perineal injury between the different techniques. In multiparous women the use of a hands-on/directed approach was associated with a significant increase in the risk of moderate (AOR 1.18, 95% CI 1.10-1.27, p < 0.001) and severe perineal injury (AOR 1.50, 95% CI 1.20-1.88, p < 0.001) compared to hands-poised/undirected. A hands poised/undirected approach could be utilised in strategies for the prevention of moderate and severe perineal injury. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Risk Assessment Training Experience (RATE) – University of Iowa Superfund Research Center.

    EPA Science Inventory

    These modules will offer hands-on training in the primary areas of risk assessment (i.e., legal background, hazard identification, dose-response assessment, exposure assessment, and risk characterization) at the University of Iowa Superfund Research Program on October 2, 2017. An...

  12. State-of-the-art on cone beam CT imaging for preoperative planning of implant placement.

    PubMed

    Guerrero, Maria Eugenia; Jacobs, Reinhilde; Loubele, Miet; Schutyser, Filip; Suetens, Paul; van Steenberghe, Daniel

    2006-03-01

    Orofacial diagnostic imaging has grown dramatically in recent years. As the use of endosseous implants has revolutionized oral rehabilitation, a specialized technique has become available for the preoperative planning of oral implant placement: cone beam computed tomography (CT). This imaging technology provides 3D and cross-sectional views of the jaws. It is obvious that this hardware is not in the same class as CT machines in cost, size, weight, complexity, and radiation dose. It is thus considered to be the examination of choice when making a risk-benefit assessment. The present review deals with imaging modalities available for preoperative planning purposes with a specific focus on the use of the cone beam CT and software for planning of oral implant surgery. It is apparent that cone beam CT is the medium of the future, thus, many changes will be performed to improve these. Any adaptation of the future systems should go hand in hand with a further dose optimalization.

  13. SYSTEMS ANALYSIS - MILITARY PERSONNEL AUTHORIZED VERSUS ON HAND

    DTIC Science & Technology

    The purpose of the report is to describe the systems analysis required to produce information on ’Military Personnel, Authorized Versus On Hand,’ for LMI R1 during the period of manual operation of the USAREUR Logistics Management Information System.

  14. 14. INTERIOR OF MAIN DECKNOTE LEVERS FROM CEILING CONTROLLED BY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. INTERIOR OF MAIN DECK--NOTE LEVERS FROM CEILING CONTROLLED BY OPERATOR. LEFT HAND LEVER CONTROLLED THROTTLE, RIGHT HAND LEVER CONTROLLED SHOT GUN SWINGER. - Dredge CINCINNATI, Docked on Ohio River at foot of Lighthill Street, Pittsburgh, Allegheny County, PA

  15. [Results of measuring neutrons doses and energy spectra inside Russian segment of the International Space Station in experiment "Matryoshka-R" using bubble detectors during the ISS-24-34 missions].

    PubMed

    Khulapko, S V; Liagushin, V I; Arkhangel'skiĭ, V V; Shurshakov, V A; Smith, M; Ing, H; Machrafi, R; Nikolaev, I V

    2014-01-01

    The paper presents the results of calculating the equivalent dose from and energy spectrum of neutrons in the right-hand crewquarters in module Zvezda of the ISS Russian segment. Dose measurements were made in the period between July, 2010 and November, 2012 (ISS Missions 24-34) by research equipment including the bubble dosimeter as part of experiment "Matryoshka-R". Neutron energy spectra in the crewquarters are in good agreement with what has been calculated for the ISS USOS and, earlier, for the MIR orbital station. The neutron dose rate has been found to amount to 196 +/- 23 microSv/d on Zvezda panel-443 (crewquarters) and 179 +/- 16 microSv/d on the "Shielding shutter" surface in the crewquarters.

  16. Measurement of irradiation effects in a RPV steel by ball indentation technique and magnetic Barkhausen noise

    NASA Astrophysics Data System (ADS)

    Kim, In-Sup; Park, Duck-Gun; Byun, Thak-Sang; Hong, Jun-Hwa

    1999-12-01

    Effects of neutron dose on the mechanical and magnetic properties of a SA508-3 nuclear pressure vessel steel were investigated by using ball indentation test technique and magnetic Barkhausen noise (BN) measurements. The samples were irradiated in a research reactor up to 1018n/cm2 (E>1 MeV) at 70 °C. The yield strength and flow curve were evaluated from the indentation load-depth curves. The change of mechanical properties showed characteristic trend with respect to neutron dose, namely near plateau, rapid increase and slow increase. On the other hand, the BN varied in a reverse manner, a slow decrease up to a neutron dose of 1016n/cm2, followed by a rapid decrease up to a dose of 1018n/cm2.

  17. Combination drilling and skiving tool

    DOEpatents

    Stone, William J.

    1989-01-01

    A combination drilling and skiving tool including a longitudinally extending hollow skiving sleeve slidably and concentrically mounted on a right-handed twist drill. Dogs or pawls provided on the internal periphery of the skiving sleeve engage with the helical grooves of the drill. During a clockwise rotation of the tool, the drill moves downwardly and the sleeve translates upwardly, so that the drill performs a drilling operation on a workpiece. On the other hand, the drill moves upwardly and the sleeve translates downwardly, when the tool is rotated in a counter-clockwise direction, and the sleeve performs a skiving operation. The drilling and skiving operations are separate, independent and exclusive of each other.

  18. Effect of data compression on diagnostic accuracy in digital hand and chest radiography

    NASA Astrophysics Data System (ADS)

    Sayre, James W.; Aberle, Denise R.; Boechat, Maria I.; Hall, Theodore R.; Huang, H. K.; Ho, Bruce K. T.; Kashfian, Payam; Rahbar, Guita

    1992-05-01

    Image compression is essential to handle a large volume of digital images including CT, MR, CR, and digitized films in a digital radiology operation. The full-frame bit allocation using the cosine transform technique developed during the last few years has been proven to be an excellent irreversible image compression method. This paper describes the effect of using the hardware compression module on diagnostic accuracy in hand radiographs with subperiosteal resorption and chest radiographs with interstitial disease. Receiver operating characteristic analysis using 71 hand radiographs and 52 chest radiographs with five observers each demonstrates that there is no statistical significant difference in diagnostic accuracy between the original films and the compressed images with a compression ratio as high as 20:1.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsui, Yusuke, E-mail: wckyh140@yahoo.co.jp; Hiraki, Takao, E-mail: takaoh@tc4.so-net.ne.jp; Gobara, Hideo, E-mail: gobara@cc.okayama-u.ac.jp

    IntroductionComputed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking.Materials and MethodsRadiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skinmore » was measured using thermoluminescent dosimeter rings.ResultsThe mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA.ConclusionRadiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.« less

  20. PWR design for low doses in the United Kingdom: The present and the future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zodiates, A.M.; Willcock, A.

    1995-03-01

    The Pressurizer Water Reactor (PWR) design chosen for adoption by Nuclear Electric plc was based on the Westinghouse Standard Nuclear Unit Power Plant System (SNUPPS). This design was developed to meet the United Kingdom (UK) requirements and those improvements are embodied in the Sizewell B plant. Nuclear Electric plc is now looking to the design of the future PWRs to be built in the UK. These PWRs will be based as replicas of the Sizewell B design, but attention will be given to reducing operator doses further. This paper details the approach in operator protection improvements incorporated at Sizewall B,more » presents the estimated annual collective dose, and identifies the approach being adopted to reduce further operator doses in future plants.« less

  1. Exposure of medical staff to radiation during osteosynthesis of proximal femoral fracture: descriptive analysis and comparison of different devices.

    PubMed

    Siedlecki, Cédric; Gauthé, Rémi; Gillibert, André; Bellenger, Kevin; Roussignol, Xavier; Ould-Slimane, Mourad

    2017-10-01

    The use of fluoroscopy is necessary during proximal femoral fracture (PFF) osteosynthesis. The frequency of these procedures justifies a description of radiation exposure and comparisons between different techniques and between the different surgical team members. This observational prospective and comparative study includes a series of 68 patients with PFF receiving osteosynthesis. Radiation exposure was assessed for all members of the operating team. The radiation dose measurements for the different members of the surgical team during PFF osteosynthesis were compared. The factors affecting the radiation dose were investigated. The mean active dosimeter readings for each operation were 7.39 µSv for the primary surgeon, 3.93 µSv for the assistant surgeon, 1.92 µSv for the instrument nurse, 1.25 µSv for the circulating nurse, and 0.64 µSv for the anaesthesiologist, respectively. Doses decreased significantly between these different members of the medical team (all p < 0.001). The dose also varied with patient age and BMI, as well as with fluoroscopy time and operating time, but not with type of fracture or type of osteosynthesis. Medical staff receives significantly different doses depending on their position in relation to the radiation source. Operating time and fluoroscopy time are the modifiable factors that affect the radiation dose. The radiation doses received by the different members of the medical teams involved in proximal femur osteosynthesis procedures all fall below the doses recommended by the International Commission on Radiation Units and Measurements.

  2. Reliability of chemotherapy preparation processes: Evaluating independent double-checking and computer-assisted gravimetric control.

    PubMed

    Carrez, Laurent; Bouchoud, Lucie; Fleury-Souverain, Sandrine; Combescure, Christophe; Falaschi, Ludivine; Sadeghipour, Farshid; Bonnabry, Pascal

    2017-03-01

    Background and objectives Centralized chemotherapy preparation units have established systematic strategies to avoid errors. Our work aimed to evaluate the accuracy of manual preparations associated with different control methods. Method A simulation study in an operational setting used phenylephrine and lidocaine as markers. Each operator prepared syringes that were controlled using a different method during each of three sessions (no control, visual double-checking, and gravimetric control). Eight reconstitutions and dilutions were prepared in each session, with variable doses and volumes, using different concentrations of stock solutions. Results were analyzed according to qualitative (choice of stock solution) and quantitative criteria (accurate, <5% deviation from the target concentration; weakly accurate, 5%-10%; inaccurate, 10%-30%; wrong, >30% deviation). Results Eleven operators carried out 19 sessions. No final preparation (n = 438) contained a wrong drug. The protocol involving no control failed to detect 1 of 3 dose errors made and double-checking failed to detect 3 of 7 dose errors. The gravimetric control method detected all 5 out of 5 dose errors. The accuracy of the doses measured was equivalent across the control methods ( p = 0.63 Kruskal-Wallis). The final preparations ranged from 58% to 60% accurate, 25% to 27% weakly accurate, 14% to 17% inaccurate and 0.9% wrong. A high variability was observed between operators. Discussion Gravimetric control was the only method able to detect all dose errors, but it did not improve dose accuracy. A dose accuracy with <5% deviation cannot always be guaranteed using manual production. Automation should be considered in the future.

  3. Dose-response relationships using brain–computer interface technology impact stroke rehabilitation

    PubMed Central

    Young, Brittany M.; Nigogosyan, Zack; Walton, Léo M.; Remsik, Alexander; Song, Jie; Nair, Veena A.; Tyler, Mitchell E.; Edwards, Dorothy F.; Caldera, Kristin; Sattin, Justin A.; Williams, Justin C.; Prabhakaran, Vivek

    2015-01-01

    Brain–computer interfaces (BCIs) are an emerging novel technology for stroke rehabilitation. Little is known about how dose-response relationships for BCI therapies affect brain and behavior changes. We report preliminary results on stroke patients (n = 16, 11 M) with persistent upper extremity motor impairment who received therapy using a BCI system with functional electrical stimulation of the hand and tongue stimulation. We collected MRI scans and behavioral data using the Action Research Arm Test (ARAT), 9-Hole Peg Test (9-HPT), and Stroke Impact Scale (SIS) before, during, and after the therapy period. Using anatomical and functional MRI, we computed Laterality Index (LI) for brain activity in the motor network during impaired hand finger tapping. Changes from baseline LI and behavioral scores were assessed for relationships with dose, intensity, and frequency of BCI therapy. We found that gains in SIS Strength were directly responsive to BCI therapy: therapy dose and intensity correlated positively with increased SIS Strength (p ≤ 0.05), although no direct relationships were identified with ARAT or 9-HPT scores. We found behavioral measures that were not directly sensitive to differences in BCI therapy administration but were associated with concurrent brain changes correlated with BCI therapy administration parameters: therapy dose and intensity showed significant (p ≤ 0.05) or trending (0.05 < p < 0.1) negative correlations with LI changes, while therapy frequency did not affect LI. Reductions in LI were then correlated (p ≤ 0.05) with increased SIS Activities of Daily Living scores and improved 9-HPT performance. Therefore, some behavioral changes may be reflected by brain changes sensitive to differences in BCI therapy administration, while others such as SIS Strength may be directly responsive to BCI therapy administration. Data preliminarily suggest that when using BCI in stroke rehabilitation, therapy frequency may be less important than dose and intensity. PMID:26157378

  4. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    NASA Astrophysics Data System (ADS)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  5. Overview of Graphical User Interface for ARRBOD (Acute Radiation Risk and BRYNTRN Organ Dose Projection)

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Hu, Shaowen; Nounu, Hatem N.; Cucinotta, Francis A.

    2010-01-01

    Solar particle events (SPEs) pose the risk of acute radiation sickness (ARS) to astronauts, because organ doses from large SPEs may reach critical levels during extra vehicular activities (EVAs) or lightly shielded spacecraft. NASA has developed an organ dose projection model of Baryon transport code (BRYNTRN) with an output data processing module of SUMDOSE, and a probabilistic model of acute radiation risk (ARR). BRYNTRN code operation requires extensive input preparation, and the risk projection models of organ doses and ARR take the output from BRYNTRN as an input to their calculations. With a graphical user interface (GUI) to handle input and output for BRYNTRN, these response models can be connected easily and correctly to BRYNTRN in a user friendly way. The GUI for the Acute Radiation Risk and BRYNTRN Organ Dose (ARRBOD) projection code provides seamless integration of input and output manipulations required for operations of the ARRBOD modules: BRYNTRN, SUMDOSE, and the ARR probabilistic response model. The ARRBOD GUI is intended for mission planners, radiation shield designers, space operations in the mission operations directorate (MOD), and space biophysics researchers. Assessment of astronauts organ doses and ARS from the exposure to historically large SPEs is in support of mission design and operation planning to avoid ARS and stay within the current NASA short-term dose limits. The ARRBOD GUI will serve as a proof-of-concept for future integration of other risk projection models for human space applications. We present an overview of the ARRBOD GUI product, which is a new self-contained product, for the major components of the overall system, subsystem interconnections, and external interfaces.

  6. Review of the energy check of an electron-only linear accelerator over a 6 year period: sensitivity of the technique to energy shift.

    PubMed

    Biggs, Peter J

    2003-04-01

    The calibration and monthly QA of an electron-only linear accelerator dedicated to intra-operative radiation therapy has been reviewed. Since this machine is calibrated prior to every procedure, there was no necessity to adjust the output calibration at any time except, perhaps, when the magnetron is changed, provided the machine output is reasonably stable. This gives a unique opportunity to study the dose output of the machine per monitor unit, variation in the timer error, flatness and symmetry of the beam and the energy check as a function of time. The results show that, although the dose per monitor unit varied within +/- 2%, the timer error within +/- 0.005 MU and the asymmetry within 1-2%, none of these parameters showed any systematic change with time. On the other hand, the energy check showed a linear drift with time for 6, 9, and 12 MeV (2.1, 3.5, and 2.5%, respectively, over 5 years), while at 15 and 18 MeV, the energy check was relatively constant. It is further shown that based on annual calibrations and RPC TLD checks, the energy of each beam is constant and that therefore the energy check is an exquisitely sensitive one. The consistency of the independent checks is demonstrated.

  7. [Median nerve constrictive operation combined with tendon transfer to treat brain paralysis convulsive deformity of hand].

    PubMed

    Ma, Shanjun; Zhou, Tianjian

    2014-05-01

    To evaluate the effectiveness of the median nerve constrictive operation combined with tendon transfer to treat the brain paralysis convulsive deformity of the hand. The clinical data from 21 cases with brain paralysis convulsive deformity of the hand were analyzed retrospectively between August 2009 and April 2012. Of them, there were 13 males and 8 females with an average age of 15 years (range, 10-29 years). The causes of the convulsive cerebral palsy included preterm deliveries in 11 cases, hypoxia asphyxia in 7, traumatic brain injury in 2, and encephalitis sequela in 1. The disease duration was 2-26 years (mean, 10.6 years). All the 21 patients had cock waists, crooking fingers, and contracture of adductors pollicis, 12 had the forearm pronation deformity. According to Ashworth criteria, there were 2 cases at level I, 5 cases at level II, 8 cases at level III, 4 cases at level IV, and 2 cases at level V. All patients had no intelligence disturbances. The forearm X-ray film showed no bone architectural changes before operation. The contraction of muscle and innervation was analyzed before operation. The median nerve constrictive operation combined with tendon transfer was performed. The functional activities and deformity improvement were evaluated during follow-up. After operation, all the patients' incision healed by first intension, without muscle atrophy and ischemic spasm. All the 21 cases were followed up 1.5-4.5 years (mean, 2.3 years). No superficial sensory loss occurred. The effectiveness was excellent in 13 cases, good in 6 cases, and poor in 2 cases, with an excellent and good rate of 90.4% at last follow-up. The median nerve constrictive operation combined with tendon transfer to treat brain paralysis convulsive deformity of the hand can remove and prevent the recurrence of spasm, achieve the orthopedic goals, to assure the restoration of motor function and the improvement of the life quality.

  8. Low-Fatigue Hand Controller For Remote Manipulator

    NASA Technical Reports Server (NTRS)

    Maclaren, Brice; Mcmurray, Gary; Lipkin, Harvey

    1993-01-01

    Universal master controller used in brace mode, in which user's forearm rests atop upper (forearm) module. Alternatively, user manipulates hand controller in side mode, which gives greater latitude for motion but requires more muscular effort. Controller provides six degrees of freedom and reflects, back to user, scaled versions of forces experienced by manipulator. Manipulator designed to condense work space into user's natural work volume. Operated by both right-handed and left-handed users. Does not interfere with user's natural movements or obstruct line of sight. Controller compact and portable.

  9. 78 FR 54485 - Apex Tool Group, LLC; Gastonia Operation Division; Including On-Site Leased Workers From Adecco...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-04

    ... Carolina. The workers are engaged in activities related to the production of mechanic's hand tool sets. The... production of mechanic's hand tool sets to a foreign country. Based on these findings, the Department is...

  10. Five-year microbiological monitoring of wards and operating theatres in southern Italy.

    PubMed

    La Fauci, V; Genovese, C; Facciolà, A; Palamara, M A R; Squeri, R

    2017-06-01

    Nosocomial infections are one of the greatest problems in public health. Several studies have highlighted the role played by the hospital environment as a possible source of transmission of nosocomial pathogens. A five-year monitoring of bacterial contamination on healthcare workers hands, surfaces most closely in contact with inpatient wards, operating theatres and "at rest" and "in use" operating theatre air samples. For the samples, we used sterile swabs, contact slides, manual API, and automated VITEK systems for identification. In the five-year period, a total of 9396 samples were collected and analysed. In ward patients, 4398 samplings were carried out with 4.7%, 9.4%, 7%, 10.8% and 7.9% positive results respectively from 2010 to 2014. For hands, 648 samplings were carried out, with a positivity of 40.74%. In operating theatres, 4188 samples were taken, with a positivity of 11.9%. Regarding air in empty and full theatres, 1962 samplings were carried out with a positivity rate equal to 31.9%. The monitoring showed a low rate of contamination with a progressive decrease in the fiveyear period on operating theatres surfaces and hands, while there was an increase in the surgical site wards and in the air of operating rooms. Our investigation has revealed the presence of pathogens on the assessed surfaces and the need for environmental monitoring, which can be a valuable tool for reducing contamination.

  11. Assessment of the effect of dextromethorphan and ketamine on the acute nociceptive threshold and wind-up of the second pain response in healthy male volunteers

    PubMed Central

    Hughes, A M; Rhodes, J; Fisher, G; Sellers, M; Growcott, J W

    2002-01-01

    Aims The aim of this study was to assess the efficacy of dextromethorphan and ketamine relative to placebo on the acute nociceptive threshold and wind-up of second pain response in healthy male volunteers. Methods The trial was a randomized, double-blind, placebo-controlled, three period crossover, double dummy design in 12 healthy male volunteers. During each of the three periods (which were separated by a 1 week washout period) each volunteer received either a single oral dose of 0.7 mg kg−1 dextromethorphan and placebo to ketamine, or placebo to dextromethorphan followed by a single intravenous injection of 0.375 mg kg−1 ketamine, or placebo to both dextromethorphan and ketamine. The trial did not schedule administration of both ketamine and dextromethorphan together. Acute nociceptive thresholds and wind-up of second pain were measured in the skin of the thenar eminence of the ventral surfaces of the right and left hands, using a SOMEDIC™ thermotest apparatus, before and at the estimated tmax for dextromethorphan (i.e. 2.15 h). Blood pressure and heart rate were also monitored before dosing and after the dosing regimen. Results Neither dextromethorphan nor ketamine had any significant effect on acute nociceptive thresholds on either hand (P>0.05). Moreover, dextromethorphan was without any significant effect (P>0.05) on the wind-up of the second pain response on either hand. The lsmean number of stimuli tolerated vs placebo (95% confidence intervals of the difference in number of stimuli in parentheses) were 15.84 vs 16.48 (−5.52, 4.24) and 11.75 vs 15.25 (−11.89, 4.90) for left- and right-hand, respectively, following dextromethorphan administration. In contrast ketamine produced significant reductions in wind-up to second pain in both the left and right hands (P=0.0002 and 0.0386, respectively). The lsmean numbers of stimuli tolerated vs placebo (95% confidence intervals of the difference in number of stimuli in parentheses) were 28.41 vs 16.48 (6.60, 17.25) and 25.00 vs 15.25 (0.58, 18.93) for left- and right-hand, respectively. Conclusions Wind-up of second pain induced by noxious heat is sensitive to intervention by ketamine, which is known to block the NMDA receptor. These data infer that the wind-up phenomenon evoked by noxious heat involves the activation of NMDA receptors. This volunteer model of pain may have utility in the evaluation of agents that modulate their antinociceptive actions via NMDA mechanisms. PMID:12047485

  12. Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

    PubMed

    den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R

    1994-06-01

    Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and the operator dose by 69%. High-output pulsed fluoroscopy with a grid-switched tube and extra filtering improves the image quality and significantly reduces both the operator dose and patient dose.

  13. Heuristic control of the Utah/MIT dextrous robot hand

    NASA Technical Reports Server (NTRS)

    Bass, Andrew H., Jr.

    1987-01-01

    Basic hand grips and sensor interactions that a dextrous robot hand will need as part of the operation of an EVA Retriever are analyzed. What is to be done with a dextrous robot hand is examined along with how such a complex machine might be controlled. It was assumed throughout that an anthropomorphic robot hand should perform tasks just as a human would; i.e., the most efficient approach to developing control strategies for the hand would be to model actual hand actions and do the same tasks in the same ways. Therefore, basic hand grips that human hands perform, as well as hand grip action were analyzed. It was also important to examine what is termed sensor fusion. This is the integration of various disparate sensor feedback paths. These feedback paths can be spatially and temporally separated, as well as, of different sensor types. Neural networks are seen as a means of integrating these varied sensor inputs and types. Basic heuristics of hand actions and grips were developed. These heuristics offer promise of control dextrous robot hands in a more natural and efficient way.

  14. Ergonomics in developing hand operated maize dehusker-sheller for farm women.

    PubMed

    Singh, S P; Singh, Surendra; Singh, Pratap

    2012-07-01

    A hand operated maize dehusker-sheller to be operated by farm women was designed and developed to dehusk and shell the maize cobs using ergonomics (anthropometric, strength and physiological workload). Axial-flow maize dehusker-sheller with 540 mm cylinder length and 380 mm diameter required 3.03 N-m torque on cylinder shaft while operating at 5.6 m s(-1) peripheral speed and 100 kg h(-1) feed rate by feeding cob one by one. This torque was 30% of isometric torque obtained at front position of handle (greatest distance) with lowest crank length. The heart rate of subject while operating the maize dehusker-sheller at 54 rpm (5.6 m s(-1)) was 142 beats min(-1). The output of 60 kg h(-1) was obtained at the feed rate of 80 kg h(-1). Two subjects can operate the machine for an hour with a rest pause of 15 min by swapping the operation. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  15. Unified treatment of microscopic boundary conditions and efficient algorithms for estimating tangent operators of the homogenized behavior in the computational homogenization method

    NASA Astrophysics Data System (ADS)

    Nguyen, Van-Dung; Wu, Ling; Noels, Ludovic

    2017-03-01

    This work provides a unified treatment of arbitrary kinds of microscopic boundary conditions usually considered in the multi-scale computational homogenization method for nonlinear multi-physics problems. An efficient procedure is developed to enforce the multi-point linear constraints arising from the microscopic boundary condition either by the direct constraint elimination or by the Lagrange multiplier elimination methods. The macroscopic tangent operators are computed in an efficient way from a multiple right hand sides linear system whose left hand side matrix is the stiffness matrix of the microscopic linearized system at the converged solution. The number of vectors at the right hand side is equal to the number of the macroscopic kinematic variables used to formulate the microscopic boundary condition. As the resolution of the microscopic linearized system often follows a direct factorization procedure, the computation of the macroscopic tangent operators is then performed using this factorized matrix at a reduced computational time.

  16. Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method

    PubMed Central

    Hu, Ying Kai; Xie, Qian Yang; Yang, Chi; Xu, Guang Zhou

    2017-01-01

    Abstract The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. PMID:28658139

  17. [Blast injuries of the hands in precarious health situation].

    PubMed

    Allah, K C; Kossoko, H; Assi Djè Bi Djè, V; Yéo, S; Bonny, R; Richard Kadio, M

    2014-06-01

    The hands of "blast" resulting from the handling of unstable explosives. Their repercussion is functional and vital in trauma patients. The authors report their experience of care from the hands of blast in precarious health situation. Between 2001 and 2012, 33 hand blasts were supported in 30 injured civilians and military, received emergency, during and after armed conflict. Two women (6.7%) and 28 men (93.3%) were received, including four teenagers (13.3%) and 26 adults (86.7%). During the war, 15 officers weapon (50%) and three civilians (10%) underwent surgery, or 60% of hand injuries. In peacetime, civilians were mostly operated in 33.3% of cases, against 6.7% of cases of agents' weapon. Nineteen hands blast (57.6%) were observed during the war and 14 in peacetime, or 42.4% of cases. The average age was 25.2 years, with extremes of 12 and 50 years. Thirteen left hands (39.4%) and 20 right hands (60.6%) were operated. The lesion concerned all the anatomical structures of the hand. It was unilateral in 27 cases (81.9%) and bilateral in three cases (9.1%). Three types of hand trauma were observed and were as follows: trauma patients with injuries of the hand (18.2%), trauma of severe and isolated proximal hand or finger amputations (75.7%), and trauma of the hand without apparent seriousness (6.1%). The associated lesion was eye (one case), chest (one case), abdominal (five cases). Debridement was performed immediate emergency (93.9%) and delayed (6.1%). The treatment was surgical hemostasis, made mainly of amputations (69.7%) and regularization of digital stumps (12.1%). The repair was performed in 18.2% of cases. One death has been reported in a polytrauma patient with chest blast. Blast injuries of the hand are common in times of war in armed agents. The young people, manual workers and children are paying a heavy price in peacetime. As land mines which affect feet, instable hand grenades are left exposed in nature. In precarious health situation, instead of a functional salvage surgery of the hand, it is a hemostasis surgery that makes many mutilated hand. The psycho-social aspect and vocational rehabilitation are additional difficulties supported. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  18. Hand-arm vibration in orthopaedic surgery: a neglected risk.

    PubMed

    Mahmood, F; Ferguson, K B; Clarke, J; Hill, K; Macdonald, E B; Macdonald, D J M

    2017-12-30

    Hand-arm vibration syndrome is an occupational disease caused by exposure to hand-arm transmitted vibration. The Health and Safety Executive has set limits for vibration exposure, including an exposure action value (EAV), where steps should be taken to reduce exposure, and an exposure limit value (ELV), beyond which vibrating equipment must not be used for the rest of the working day. To measure hand-arm transmitted vibration among orthopaedic surgeons, who routinely use hand-operated saws. We undertook a cadaveric study measuring vibration associated with a tibial cut using battery-operated saws. Three surgeons undertook three tibial cuts each on cadaveric tibiae. Measurements were taken using a frequency-weighted root mean square acceleration, with the vibration total value calculated as the root of the sums squared in each of the three axes. A mean (SD) vibration magnitude of 1 (0.2) m/s2 in the X-axis, 10.3 (1.9) m/s2 in the Y-axis and 4.2 (1.3) m/s2 in the Z-axis was observed. The weighted root mean squared magnitude of vibration was 11.3 (1.7) m/s2. These results suggest an EAV of 23 min and ELV of 1 h 33 min using this equipment. Our results demonstrate that use of a battery-operated sagittal saw can transmit levels of hand-arm vibration approaching the EAV or ELV through prolonged use. Further study is necessary to quantify this risk and establish whether surveillance is necessary for orthopaedic surgeons. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  19. Efficacy of RADPAD® protection drape in reducing radiation exposure to the primary operator during Transcatheter Aortic Valve Implantation (TAVI).

    PubMed

    Sharma, Divyesh; Ramsewak, Adesh; Manoharan, Ganesh; Spence, Mark S

    2016-02-01

    The efficacy of RADPAD® (a sterile, lead-free drape) has been demonstrated to reduce the scatter radiation to the primary operator during fluoroscopic procedures. However, the use of the RADPAD® during TAVI procedures has not been studied. Transcatheter aortic valve implantation (TAVI) is now an established treatment for patients with symptomatic severe aortic stenosis who are deemed inoperable or at high risk for conventional surgical aortic valve replacement (AVR). Consequently the radiation exposure to the patient and the interventional team from this procedure has become a matter of interest and importance. Methods to reduce radiation exposure to the interventional team during this procedure should be actively investigated. In this single center prospective study, we determined the radiation dose during this procedure and the efficacy of RADPAD® in reducing the radiation dose to the primary operator. Fifty consecutive patients due to undergo elective TAVI procedures were identified. Patients were randomly assigned to undergo the procedure with or without the use of a RADPAD® drape. There were 25 patients in each group and dosimetry was performed at the left eye level of the primary operator. The dosimeter was commenced at the start of the procedure, and the dose was recorded immediately after the end of the procedure. Fluoroscopy times and DAP were also recorded prospectively. Twenty-five patients underwent transfemoral TAVI using a RADPAD® and 25 with no-RADPAD®. The mean primary operator radiation dose was significantly lower in the RADPAD group at 14.8 mSv vs. 24.3 mSv in the no-RADPAD group (P=0.008). There was no significant difference in fluoroscopy times or dose-area products between the two patient groups. The dose to the primary operator relative to fluoroscopy time (RADPAD: slope=0.325; no RADPAD: slope=1.148; analysis of covariance F=7.47, P=0.009) and dose area product (RADPAD: slope=0.0007; no RADPAD: slope=0.002; analysis of covariance F=7.38; P=0.009) was smaller in the RADPAD group compared to no-RADPAD group. Use of a RADPAD® significantly reduces radiation exposure to the primary operator during TAVI procedures.

  20. Degree of freezing does not affect efficacy of frozen gloves for prevention of docetaxel-induced nail toxicity in breast cancer patients.

    PubMed

    Ishiguro, H; Takashima, S; Yoshimura, K; Yano, I; Yamamoto, T; Niimi, M; Yamashiro, H; Ueno, T; Takeuchi, M; Sugie, T; Yanagihara, K; Toi, M; Fukushima, M

    2012-09-01

    Frozen gloves (FG) are effective in preventing docetaxel-induced nail toxicity (DNT), but uncomfortable. The preventive effect of FG for DNT was compared using a standard (-25 to -30°C) or more comfortable (-10 to -20°C) preparation. Breast cancer patients receiving docetaxel were eligible. Each patient wore an FG (prepared at -10 to -20°C for 90 min) for 60 min without replacement on the right hand. The left hand was protected by standard methods (FG prepared at -25 to -30°C overnight and worn for 90 min with replacement at 45 min). The primary endpoint was DNT occurrence at 5 months. Secondary endpoints included docetaxel exposure [cumulative dose and area under the blood concentration time curve (AUC)] until DNT occurrence and discomfort from FG. The pharmacokinetics of docetaxel was assessed. From 23 patients enrolled between December 2006 and June 2010, seven who received docetaxel for less than 5 months were excluded from evaluation. The median accumulated docetaxel dose was 700 mg/m(2) (340-1430 mg/m(2)). Within 5 months of FG use, none developed protocol-defined DNT in either hand. Two patients (13%) developed DNT at 7.2 and 7.3 months, respectively, both at -10 to -20°C. In the control hand (-25 to -30°C), discomfort occurred in 92% of the cycles, compared to 15% in the experimental hand (-10 to -20°C). Five patients (22%) experienced pain at -25 to -30°C, but none did at -10 to -20°C. The degree of docetaxel exposure was not related to DNT occurrence in our study. A convenient preparation of FG at -10 to -20°C is almost as effective as a standard preparation at -25 to -30°C, with significantly less discomfort.

  1. Infection control in the operating room: is it more than a clean dish?

    PubMed

    Loftus, Randy W

    2016-04-01

    Healthcare-associated infections (HCAIs) are driven by a complex interplay between host defenses, pathogen traits, and pathogen transmission. A better understanding of each of these factors is required to extend infection control beyond antibiotic therapy to improvements in basic preventive measures that can achieve sustained HCAI reductions. The purpose of this article is to review recent advancements in our understanding of these issues for the operating room environment. The importance and implications of intraoperative bacterial transmission have been solidified, and hyper transmissible, virulent, and antibiotic resistant bacterial strains have been characterized. As a result, a best practice for improved intraoperative infection control has been delineated. Little advancement has been made in our understanding of the efficacy of higher inspired oxygen concentrations, improved postoperative glucose control, perioperative normothermia, and prophylactic antibiotic selection, timing, and dose for HCAI prevention. Recent work has led to the development of evidence-based hand hygiene, environmental cleaning, patient decolonization, and intravascular catheter design and handling improvement strategies. Evidence suggests that a best practice for postoperative infection control is a multimodal program that utilizes these interventions to target patient, provider, and environmental reservoirs in parallel. The development of novel diagnostic tools for targeted attenuation of hyper virulent, transmissible and resistant strains/strain characteristics is indicated to improve patient decolonization efforts.

  2. Hand injuries from snow blowers: a report of an epidemic.

    PubMed

    Tetz, D J; Aghababian, R

    1995-01-01

    During a record snowfall in Worcester, Massachusetts, 11-13 December 1992, 37 male patients with hand injuries suffered during snow blower operation were seen at three area hospitals. Two previous reports describe 13 patients seen over a 3-year period and 28 patients over a 12-year period. This report describes the largest number of hand injuries from snow blowers that have occurred over a 48-hour period. The snow was unusual because of the high water density in the initial 9 inches (23 cm) that fell at an average temperature of 33 degrees F (0.6 degree C) with the final depth of 30 inches (76 cm), causing the machines to become clogged. Patients admitted to reaching into a running machine in 35/37 (95%) cases, 11/37 (30%) claimed the auger and impeller blades were disengaged, and 2/37 (5%) patients claimed their injuries occurred with the engines turned off. All injuries occurred when the patients placed their hands down the chute, contacting the impeller blades. Injuries involved 32 long, 15 ring, 13 index, and five small fingers and ranged from simple lacerations to partial phalangeal amputations. The majority, 27/37 (73%), were managed in emergency departments without interventions in the operating suites. Infection occurred in one patient who had the lesion repaired in the operating suite. As in previous studies, no differences were found for the variables of snow-blower age, type, or horsepower, or on experience level or age of the operators.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Necrosis of the femoral head after kidney transplantation.

    PubMed

    Lausten, G S; Lemser, T; Jensen, P K; Egfjord, M

    1998-12-01

    We reviewed the medical records of 750 patients (445 men, 305 women), who had received a kidney transplant during the period 1968-1995, for any sign of necrosis of the femoral head. For post-operative immunosuppression, 374 patients had received high-dose corticosteroids (average 12.5 g during the first year post-operatively), while 376 patients had received low-dose corticosteroids (average 6.5 g during the first year post-operatively) and cyclosporin A. Survival curves according to Kaplan and Meier (J Am Stat Ass 1958: 53: 457-481) were constructed. In the high-dose steroid group, 42/374 patients (11.2%) developed femoral head necrosis, at an average of 26.2 months post-transplantation. In the low-dose steroid group, only 19/376 (5.1%) patients developed this complication, at an average of 20.5 months post-transplantation. This difference in numbers of femoral head necroses was highly significant (p < 0.005). We conclude that steroid doses should be minimized whenever feasible in post-transplant immunosuppression therapy.

  4. A Hand-in-Hand Approach for Security and Development in Sub-Saharan Africa

    DTIC Science & Technology

    2010-06-15

    peacekeeping operations and large contingents deployed in Democratic Republic of the Congo (DRC), the Darfur region of Sudan, Lebanon , Liberia...several SSA countries improve their ability to investigate, prosecute, and adjudicate gender -based violence and provide support to victims. 19

  5. Mechanical evaluation of articulating instruments and cross-handed manipulation in laparoendoscopic single-site surgery.

    PubMed

    Xu, An An; Zhu, Jiang Fan; Xie, Xiaofeng; Su, Yuantao

    2014-08-01

    Laparoendoscopic single-site surgery (LESS) is limited by loss of triangulation and internal instruments conflict. To overcome these difficulties, some concepts have been introduced, namely, articulating instruments and cross-handed manipulation, which causes the right hand to control the left instrument tip and vice versa. The aim of this study was to compare task performance with different approaches based on a mechanical evaluation platform. A LESS mechanical evaluation platform was set up to investigate the performance of 2 tasks (suture pass-through rings and clip-cut) with 3 different settings: uncrossed manipulation with straight instruments (group A, the control group), uncrossed manipulation with articulating instruments (group B), and cross-handed manipulation with articulating instruments (group C). The operation time and average load required for accomplishment of the standard tasks were measured. Group A presented significantly better time scores than group B, and group C consumed the longest time to accomplish the 2 tasks (P < .05). Comparing of average load required to perform the suture pass-through rings task, it differed significantly between dominant and nondominant hand in all groups (P < .01) and was less in group A and group B than group C in dominant hand (P < .01), while it was almost the same in all groups in the nondominant hand. In terms of average load requirement to accomplish clip-cut task, it was almost equal not only between group A and B but also between dominant and nondominant hand while the increase reached statistical significance when comparing group C with other groups (P < .05). Compared with conventional devices and maneuvering techniques, articulating instruments and cross-handed manipulation are associated with longer operation time and higher workload. Instruments with better maneuverability should be developed in the future for LESS. © The Author(s) 2013.

  6. The Plastic Surgery Hand Curriculum.

    PubMed

    Silvestre, Jason; Levin, L Scott; Serletti, Joseph M; Chang, Benjamin

    2015-12-01

    Designing an effective hand rotation for plastic surgery residents is difficult. The authors address this limitation by elucidating the critical components of the hand curriculum during plastic surgery residency. Hand questions on the Plastic Surgery In-Service Training Exam for six consecutive years (2008 to 2013) were characterized by presence of imaging, vignette setting, question taxonomy, answer domain, anatomy, and topic. Answer references were quantified by source and year of publication. Two hundred sixty-six questions were related to hand surgery (22.7 percent of all questions; 44.3 per year) and 61 were accompanied by an image (22.9 percent). Vignettes tended to be clinic- (50.0 percent) and emergency room-based (35.3 percent) (p < 0.001). Questions required decision-making (60.5 percent) over interpretation (25.9 percent) and recall skills (13.5 percent) (p < 0.001). Answers focused on interventions (57.5 percent) over anatomy/pathology (25.2 percent) and diagnoses (17.3 percent) (p < 0.001). Nearly half of the questions focused on the digits. The highest yield topics were trauma (35.3 percent), reconstruction (24.4 percent), and aesthetic and functional problems (14.2 percent). The Journal of Hand Surgery (American volume) (20.5 percent) and Plastic and Reconstructive Surgery (18.0 percent) were the most-cited journals, and the median publication lag was 7 years. Green's Operative Hand Surgery was the most-referenced textbook (41.8 percent). These results will enable trainees to study hand surgery topics with greater efficiency. Faculty can use these results to ensure that tested topics are covered during residency training. Thus, a benchmark is established to improve didactic, clinical, and operative experiences in hand surgery.

  7. Rapid prototyping prosthetic hand acting by a low-cost shape-memory-alloy actuator.

    PubMed

    Soriano-Heras, Enrique; Blaya-Haro, Fernando; Molino, Carlos; de Agustín Del Burgo, José María

    2018-06-01

    The purpose of this article is to develop a new concept of modular and operative prosthetic hand based on rapid prototyping and a novel shape-memory-alloy (SMA) actuator, thus minimizing the manufacturing costs. An underactuated mechanism was needed for the design of the prosthesis to use only one input source. Taking into account the state of the art, an underactuated mechanism prosthetic hand was chosen so as to implement the modifications required for including the external SMA actuator. A modular design of a new prosthesis was developed which incorporated a novel SMA actuator for the index finger movement. The primary objective of the prosthesis is achieved, obtaining a modular and functional low-cost prosthesis based on additive manufacturing executed by a novel SMA actuator. The external SMA actuator provides a modular system which allows implementing it in different systems. This paper combines rapid prototyping and a novel SMA actuator to develop a new concept of modular and operative low-cost prosthetic hand.

  8. Shutdown Dose Rate Analysis for the long-pulse D-D Operation Phase in KSTAR

    NASA Astrophysics Data System (ADS)

    Park, Jin Hun; Han, Jung-Hoon; Kim, D. H.; Joo, K. S.; Hwang, Y. S.

    2017-09-01

    KSTAR is a medium size fully superconducting tokamak. The deuterium-deuterium (D-D) reaction in the KSTAR tokamak generates neutrons with a peak yield of 3.5x1016 per second through a pulse operation of 100 seconds. The effect of neutron generation from full D-D high power KSTAR operation mode to the machine, such as activation, shutdown dose rate, and nuclear heating, are estimated for an assurance of safety during operation, maintenance, and machine upgrade. The nuclear heating of the in-vessel components, and neutron activation of the surrounding materials have been investigated. The dose rates during operation and after shutdown of KSTAR have been calculated by a 3D CAD model of KSTAR with the Monte Carlo code MCNP5 (neutron flux and decay photon), the inventory code FISPACT (activation and decay photon) and the FENDL 2.1 nuclear data library.

  9. Gamma-radiation effects on luminescence properties of Eu3+ activated LaPO4 phosphor

    NASA Astrophysics Data System (ADS)

    Vujčić, Ivica; Gavrilović, Tamara; Sekulić, Milica; Mašić, Slobodan; Putić, Slaviša; Papan, Jelena; Dramićanin, Miroslav D.

    2018-05-01

    Eu3+ activated LaPO4 phosphors were prepared by a high-temperature solid-state method and irradiated to different high-doses gamma-radiation in the 0-4 MGy range. No effects of high-doses of high-energy radiation on phosphor's morphology and structure were observed, as documented by electron microscopy and X-ray diffraction measurements. On the other hand, photoluminescence measurements showed that emission properties of phosphor were affected by gamma-radiation; changes in radiative properties being prominent for absorbed radiation doses up to 250 kGy after which no additional changes are observed. Judd-Ofelt analysis of emission spectra is performed to thoroughly investigate radiative properties of phosphors. Analysis showed that radiative transition probability of Eu3+ emission decreases while non-radiative probability increases upon gamma-irradiation. Quantum efficiency of emission is decreased from about 46% to 35% when Eu3+ doped LaPO4 powders are exposed to gamma-radiation of 250 kGy dose, showing no additional decrease for higher gamma-radiation doses.

  10. Design and control of five fingered under-actuated robotic hand

    NASA Astrophysics Data System (ADS)

    Sahoo, Biswojit; Parida, Pramod Kumar

    2018-04-01

    Now a day's research regarding humanoid robots and its application in different fields (industry, household, rehabilitation and exploratory) is going on entire the globe. Among which a challenging topic is to design a dexterous robotic hand which not only can perform as a hand of a robot but also can be used in re habilitation. The basic key concern is a dexterous robot hand which can be able to mimic the function of biological hand to perform different operations. This thesis work is regarding design and control of a under-actuated robotic hand consisting of four under actuated fingers (index finger, middle finger, little finger and ring finger ) , a thumb and a dexterous palm which can copy the motions and grasp type of human hand which having 21degrees of freedom instead of 25Degree Of Freedom.

  11. Dose measurements and radiation protection measures in gynecological radium therapy for medical-technical assistants and nursing staff (in German)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmidt, B.

    Thesis. Appropriate measures to decrease radiation exposure of medical- technical assistants and nursing staff of hospitals with radiotherapy departments require personnel dose measurements during the different working operations. The measured values were in all cases below the maximum permissible doses; they are presented in tabular form for the various operations. Proposals are made for a further reduction of radiation exposure in particular fields of application. (GE)

  12. A compact DD neutron generator-based NAA system to quantify manganese (Mn) in bone in vivo.

    PubMed

    Liu, Yingzi; Byrne, Patrick; Wang, Haoyu; Koltick, David; Zheng, Wei; Nie, Linda H

    2014-09-01

    A deuterium-deuterium (DD) neutron generator-based neutron activation analysis (NAA) system has been developed to quantify metals, including manganese (Mn), in bone in vivo. A DD neutron generator with a flux of up to 3*10(9) neutrons s(-1) was set up in our lab for this purpose. Optimized settings, including moderator, reflector, and shielding material and thickness, were selected based on Monte Carlo (MC) simulations conducted in our previous work. Hand phantoms doped with different Mn concentrations were irradiated using the optimized DD neutron generator irradiation system. The Mn characteristic γ-rays were collected by an HPGe detector system with 100% relative efficiency. The calibration line of the Mn/calcium (Ca) count ratio versus bone Mn concentration was obtained (R(2) = 0.99) using the hand phantoms. The detection limit (DL) was calculated to be about 1.05 μg g(-1) dry bone (ppm) with an equivalent dose of 85.4 mSv to the hand. The DL can be reduced to 0.74 ppm by using two 100% HPGe detectors. The whole body effective dose delivered to the irradiated subject was calculated to be about 17 μSv. Given the average normal bone Mn concentration of 1 ppm in the general population, this system is promising for in vivo bone Mn quantification in humans.

  13. Establishment and validation of a method for multi-dose irradiation of cells in 96-well microplates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abatzoglou, Ioannis; Zois, Christos E.; Pouliliou, Stamatia

    2013-02-15

    Highlights: ► We established a method for multi-dose irradiation of cell cultures within a 96-well plate. ► Equations to adjust to preferable dose levels are produced and provided. ► Up to eight different dose levels can be tested in one microplate. ► This method results in fast and reliable estimation of radiation dose–response curves. -- Abstract: Microplates are useful tools in chemistry, biotechnology and molecular biology. In radiobiology research, these can be also applied to assess the effect of a certain radiation dose delivered to the whole microplate, to test radio-sensitivity, radio-sensitization or radio-protection. Whether different radiation doses can bemore » accurately applied to a single 96-well plate to further facilitate and accelerated research by one hand and spare funds on the other, is a question dealt in the current paper. Following repeated ion-chamber, TLD and radiotherapy planning dosimetry we established a method for multi-dose irradiation of cell cultures within a 96-well plate, which allows an accurate delivery of desired doses in sequential columns of the microplate. Up to eight different dose levels can be tested in one microplate. This method results in fast and reliable estimation of radiation dose–response curves.« less

  14. Measurements of occupational exposure for a technologist performing 18F FDG PET scans.

    PubMed

    Biran, Talma; Weininger, Jolie; Malchi, Shalom; Marciano, Rami; Chisin, Roland

    2004-11-01

    Radiation doses to one PET technologist performing 100 18F FDG (18F fluorodeoxyglucose) imaging procedures were measured in a clinical setting using two types of thermoluminescent dosimeter (TLD) badges, one finger-ring TLD and one electronic pocket dosimeter (EPD). 18F FDG was handled either with unshielded or with viewing window tungsten shielded syringes. The resulting doses using unshielded syringes were 13.8 +/- 0.8 microSv/370 MBq and 14.3 +/- 0.4 microSv/370 MBq, measured with TLD 100 and with TLD 700H/600H, respectively. For the same series of measurements, the doses obtained using shielded syringes were 10.7 +/- 0.4 microSv/370 MBq and 7.2 +/- 2.1 microSv/370 MBq with TLD700H/600H and with EPD, respectively. The dose to the right hand from shielded syringes was 69.3 +/- 5.5 microSv/370 MBq. All these values are within the ICRP recommended dose limits. Extrapolated to 725 examinations per year, the resulting effective dose measured with TLD would be 10 mSv with unshielded and 7.5 mSv with shielded syringes, respectively (25% dose reduction). The doses measured by TLD were consistently higher than those measured by EPD, suggesting that EPD measurements might underestimate occupational doses.

  15. [Dose rate-dependent cellular and molecular effects of ionizing radiation].

    PubMed

    Przybyszewski, Waldemar M; Wideł, Maria; Szurko, Agnieszka; Maniakowski, Zbigniew

    2008-09-11

    The aim of radiation therapy is to kill tumor cells while minimizing damage to normal cells. The ultimate effect of radiation can be apoptotic or necrotic cell death as well as cytogenetic damage resulting in genetic instability and/or cell death. The destructive effects of radiation arise from direct and indirect ionization events leading to peroxidation of macromolecules, especially those present in lipid-rich membrane structures as well as chromatin lipids. Lipid peroxidative end-products may damage DNA and proteins. A characteristic feature of radiation-induced peroxidation is an inverse dose-rate effect (IDRE), defined as an increase in the degree of oxidation(at constant absorbed dose) accompanying a lower dose rate. On the other hand, a low dose rate can lead to the accumulation of cells in G2, the radiosensitive phase of the cell cycle since cell cycle control points are not sensitive to low dose rates. Radiation dose rate may potentially be the main factor improving radiotherapy efficacy as well as affecting the intensity of normal tissue and whole-body side effects. A better understanding of dose rate-dependent biological effects may lead to improved therapeutic intervention and limit normal tissue reaction. The study reviews basic biological effects that depend on the dose rate of ionizing radiation.

  16. Technical challenges in the construction of the steady-state stellarator Wendelstein 7-X

    NASA Astrophysics Data System (ADS)

    Bosch, H.-S.; Wolf, R. C.; Andreeva, T.; Baldzuhn, J.; Birus, D.; Bluhm, T.; Bräuer, T.; Braune, H.; Bykov, V.; Cardella, A.; Durodié, F.; Endler, M.; Erckmann, V.; Gantenbein, G.; Hartmann, D.; Hathiramani, D.; Heimann, P.; Heinemann, B.; Hennig, C.; Hirsch, M.; Holtum, D.; Jagielski, J.; Jelonnek, J.; Kasparek, W.; Klinger, T.; König, R.; Kornejew, P.; Kroiss, H.; Krom, J. G.; Kühner, G.; Laqua, H.; Laqua, H. P.; Lechte, C.; Lewerentz, M.; Maier, J.; McNeely, P.; Messiaen, A.; Michel, G.; Ongena, J.; Peacock, A.; Pedersen, T. S.; Riedl, R.; Riemann, H.; Rong, P.; Rust, N.; Schacht, J.; Schauer, F.; Schroeder, R.; Schweer, B.; Spring, A.; Stäbler, A.; Thumm, M.; Turkin, Y.; Wegener, L.; Werner, A.; Zhang, D.; Zilker, M.; Akijama, T.; Alzbutas, R.; Ascasibar, E.; Balden, M.; Banduch, M.; Baylard, Ch.; Behr, W.; Beidler, C.; Benndorf, A.; Bergmann, T.; Biedermann, C.; Bieg, B.; Biel, W.; Borchardt, M.; Borowitz, G.; Borsuk, V.; Bozhenkov, S.; Brakel, R.; Brand, H.; Brown, T.; Brucker, B.; Burhenn, R.; Buscher, K.-P.; Caldwell-Nichols, C.; Cappa, A.; Cardella, A.; Carls, A.; Carvalho, P.; Ciupiński, Ł.; Cole, M.; Collienne, J.; Czarnecka, A.; Czymek, G.; Dammertz, G.; Dhard, C. P.; Davydenko, V. I.; Dinklage, A.; Drevlak, M.; Drotziger, S.; Dudek, A.; Dumortier, P.; Dundulis, G.; Eeten, P. v.; Egorov, K.; Estrada, T.; Faugel, H.; Fellinger, J.; Feng, Y.; Fernandes, H.; Fietz, W. H.; Figacz, W.; Fischer, F.; Fontdecaba, J.; Freund, A.; Funaba, T.; Fünfgelder, H.; Galkowski, A.; Gates, D.; Giannone, L.; García Regaña, J. M.; Geiger, J.; Geißler, S.; Greuner, H.; Grahl, M.; Groß, S.; Grosman, A.; Grote, H.; Grulke, O.; Haas, M.; Haiduk, L.; Hartfuß, H.-J.; Harris, J. H.; Haus, D.; Hein, B.; Heitzenroeder, P.; Helander, P.; Heller, R.; Hidalgo, C.; Hildebrandt, D.; Höhnle, H.; Holtz, A.; Holzhauer, E.; Holzthüm, R.; Huber, A.; Hunger, H.; Hurd, F.; Ihrke, M.; Illy, S.; Ivanov, A.; Jablonski, S.; Jaksic, N.; Jakubowski, M.; Jaspers, R.; Jensen, H.; Jenzsch, H.; Kacmarczyk, J.; Kaliatk, T.; Kallmeyer, J.; Kamionka, U.; Karaleviciu, R.; Kern, S.; Keunecke, M.; Kleiber, R.; Knauer, J.; Koch, R.; Kocsis, G.; Könies, A.; Köppen, M.; Koslowski, R.; Koshurinov, J.; Krämer-Flecken, A.; Krampitz, R.; Kravtsov, Y.; Krychowiak, M.; Krzesinski, G.; Ksiazek, I.; Kubkowska, M.; Kus, A.; Langish, S.; Laube, R.; Laux, M.; Lazerson, S.; Lennartz, M.; Li, C.; Lietzow, R.; Lohs, A.; Lorenz, A.; Louche, F.; Lubyako, L.; Lumsdaine, A.; Lyssoivan, A.; Maaßberg, H.; Marek, P.; Martens, C.; Marushchenko, N.; Mayer, M.; Mendelevitch, B.; Mertens, Ph.; Mikkelsen, D.; Mishchenko, A.; Missal, B.; Mizuuchi, T.; Modrow, H.; Mönnich, T.; Morizaki, T.; Murakami, S.; Musielok, F.; Nagel, M.; Naujoks, D.; Neilson, H.; Neubauer, O.; Neuner, U.; Nocentini, R.; Noterdaeme, J.-M.; Nührenberg, C.; Obermayer, S.; Offermanns, G.; Oosterbeek, H.; Otte, M.; Panin, A.; Pap, M.; Paquay, S.; Pasch, E.; Peng, X.; Petrov, S.; Pilopp, D.; Pirsch, H.; Plaum, B.; Pompon, F.; Povilaitis, M.; Preinhaelter, J.; Prinz, O.; Purps, F.; Rajna, T.; Récsei, S.; Reiman, A.; Reiter, D.; Remmel, J.; Renard, S.; Rhode, V.; Riemann, J.; Rimkevicius, S.; Riße, K.; Rodatos, A.; Rodin, I.; Romé, M.; Roscher, H.-J.; Rummel, K.; Rummel, Th.; Runov, A.; Ryc, L.; Sachtleben, J.; Samartsev, A.; Sanchez, M.; Sano, F.; Scarabosio, A.; Schmid, M.; Schmitz, H.; Schmitz, O.; Schneider, M.; Schneider, W.; Scheibl, L.; Scholz, M.; Schröder, G.; Schröder, M.; Schruff, J.; Schumacher, H.; Shikhovtsev, I. V.; Shoji, M.; Siegl, G.; Skodzik, J.; Smirnow, M.; Speth, E.; Spong, D. A.; Stadler, R.; Sulek, Z.; Szabó, V.; Szabolics, T.; Szetefi, T.; Szökefalvi-Nagy, Z.; Tereshchenko, A.; Thomsen, H.; Thumm, M.; Timmermann, D.; Tittes, H.; Toi, K.; Tournianski, M.; Toussaint, U. v.; Tretter, J.; Tulipán, S.; Turba, P.; Uhlemann, R.; Urban, J.; Urbonavicius, E.; Urlings, P.; Valet, S.; Van Eester, D.; Van Schoor, M.; Vervier, M.; Viebke, H.; Vilbrandt, R.; Vrancken, M.; Wauters, T.; Weissgerber, M.; Weiß, E.; Weller, A.; Wendorf, J.; Wenzel, U.; Windisch, T.; Winkler, E.; Winkler, M.; Wolowski, J.; Wolters, J.; Wrochna, G.; Xanthopoulos, P.; Yamada, H.; Yokoyama, M.; Zacharias, D.; Zajac, J.; Zangl, G.; Zarnstorff, M.; Zeplien, H.; Zoletnik, S.; Zuin, M.

    2013-12-01

    The next step in the Wendelstein stellarator line is the large superconducting device Wendelstein 7-X, currently under construction in Greifswald, Germany. Steady-state operation is an intrinsic feature of stellarators, and one key element of the Wendelstein 7-X mission is to demonstrate steady-state operation under plasma conditions relevant for a fusion power plant. Steady-state operation of a fusion device, on the one hand, requires the implementation of special technologies, giving rise to technical challenges during the design, fabrication and assembly of such a device. On the other hand, also the physics development of steady-state operation at high plasma performance poses a challenge and careful preparation. The electron cyclotron resonance heating system, diagnostics, experiment control and data acquisition are prepared for plasma operation lasting 30 min. This requires many new technological approaches for plasma heating and diagnostics as well as new concepts for experiment control and data acquisition.

  17. CONICAL, RADIOGRAPHIC, AND PATIENT-REPORTED RESULTS OF SURFACE REPLACING PROXIMAL INTERPHALANGEAL JOINT ARTHROPLASTY OF THE HAND

    PubMed Central

    Amirtharajah, Mohana; Fufa, Duretti; Lightdale, Nina; Weiland, Andew

    2011-01-01

    The purpose of this study was to evaluate the one-year clinical, radiologic and patient-reported results of surface-replacing proximal interphalangeal joint arthroplasty (SR-PIP) of the hand. Fifteen patients with 18 joints underwent the procedure, and nine patients with 11 joints had follow-up of at least one year's duration. Of these joints, six had a diagnosis of osteoarthritis with no history of trauma, three had post-traumatic arthritis, one had psoriatic arthritis, and one had erosive arthritis. The mean clinical follow-up was at 3.3 years, and the mean radiographic follow-up was at 3.1 years. The average post-operative gain in range of motion at the PIP joint was 28 degrees and was statistically significant. Six patients completed self-reported questionnaires at a mean of 4.8 years post-operatively. The mean Disabilities of the Arm, Shoulder and Hand (DASH) score post-operatively was 17, and the Michigan Hand Questionnaire (MHQ) score for overall satisfaction was 70. There were three complications but only one reoperation. Seven of 11 joints showed some evidence of subsidence on follow-up radiographic examination. However, no joints were revised sec-ondary to loosening. Longer follow-up is needed to determine if this observable radiologic subsidence leads to symptomatic loosening of the implant PMID:22096433

  18. 1950-nm diode laser-assisted microanastomoses (LAMA): an innovative surgical tool for hand surgery emergencies.

    PubMed

    Leclère, Franck Marie; Schoofs, Michel; Vogt, Peter; Casoli, Vincent; Mordon, Serge

    2015-05-01

    Based on previous observations, the 1950-nm diode laser seems to be an ideal wavelength for laser microvascular anastomoses. The data presented here, part of a larger ongoing study, assess its use in emergency hand surgery. Between 2011 and 2014, 11 patients were operated on for hand trauma with laser-assisted microanastomoses (LAMA) and prospectively analysed. LAMA was performed with a 1950-nm diode laser after placement of equidistant stitches. For vessel size <1.5 mm, the following laser parameters were used: spot size 400 μm, five spots for each wall, power 125 mW, and arterial/venous fluence 100/90 J/cm(2) (spot duration 1/0.9 s). Mean operating time for arterial and venous microanastomoses was 7.3 ± 1.4 and 8.7 ± 1.0 min, respectively. Three anastomoses required a secondary laser application. Arterial and venous patency rates were 100 % at the time of surgery. The success rate for the 11 procedures assessed clinically and with the Doppler was 100 %. The technique is compared to the current literature. The 1950-nm LAMA is a reliable tool with excellent results in emergency hand surgery. The system is very compact and transportable for utilization in the emergency operating room.

  19. 7 CFR 1485.22 - Submissions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... this regulation either by hand delivery to the Director, Marketing Operations Staff, FAS, USDA or by... be deemed submitted as of the date received by the Director, Marketing Operations Staff, FAS, USDA. ...

  20. A prospective case control comparison of the ZeroGravity system versus a standard lead apron as radiation protection strategy in neuroendovascular procedures.

    PubMed

    Haussen, Diogo C; Van Der Bom, Imramsjah Martijn John; Nogueira, Raul G

    2016-10-01

    We aimed to compare the performance of the ZeroGravity (ZG) system (radiation protection system composed by a suspended lead suit) against the use of standard protection (lead apron (LA), thyroid shield, lead eyeglasses, table skirts, and ceiling suspended shield) in neuroangiography procedures. Radiation exposure data were prospectively collected in consecutive neuroendovascular procedures between December 2014 and February 2015. Operator No 1 was assigned to the use of an LA (plus lead glasses, thyroid shield, and a 1 mm hanging shield at the groin) while operator No 2 utilized the ZG system. Dosimeters were used to measure peak skin dose for the head, thyroid, and left foot. The two operators performed a total of 122 procedures during the study period. The ZG operator was more commonly the primary operator compared with the LA operator (85% vs 71%; p=0.04). The mean anterior-posterior (AP), lateral, and cumulative dose area product (DAP) radiation exposure as well as the mean fluoroscopy time were not statistically different between the operators' cases. The peak skin dose to the head of the operator with LA was 2.1 times higher (3380 vs 1600 μSv), while the thyroid was 13.9 (4460 vs 320 μSv), the mediastinum infinitely (520 vs 0 μSv), and the foot 3.3 times higher (4870 vs 1470 μSv) compared with the ZG operator, leading to an overall accumulated dose 4 times higher. The ratio of cumulative operator received dose/total cumulative DAP was 2.5 higher on the LA operator. The ZG radiation protection system leads to substantially lower radiation exposure to the operator in neurointerventional procedures. However, substantial exposure may still occur at the level of the lens and thyroid to justify additional protection. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  1. Indoor and outdoor radon measurements at lung cancer patients' homes in the dwellings of Rize Province in Turkey.

    PubMed

    Özen, Songül Akbulut; Celik, Necati; Dursun, Emrehan; Taskın, Halim

    2018-06-01

    In this study, indoor and outdoor radon ( 222 Rn) surveys were carried out in the summer and winter seasons in homes of one hundred lung cancer patients in the year 2013-2014. The aim was to investigate the relationship between radon and cancer patients. Lung cancer patients completed a questionnaire concerning their living environment, various physical parameters and living habits. Pearson correlation and t tests revealed no meaningful results between radon concentrations, on one hand, and environmental and personal living habits, on the other hand. Consequently, the BEIR VI model was adapted and 222 Rn exposure was estimated to be responsible for about 12% of the lung cancer incidences in the winter season and around 5% in the summer season in the Rize Province. However, due to the limited number of data and numerous parameters that could lead to lung cancer, the estimations done with the model should be taken very lightly. The annual effective doses due to inhalation of indoor and outdoor 222 Rn were estimated to be, respectively, 1.43 and 0.94 mSv y -1 . The indoor and outdoor annual effective doses were, respectively, close and below the world annual effective dose (1.3 mSv y -1 ). At the district level, the indoor annual effective dose equivalent in the İyidere district was 4.52 mSv y -1 , which was 3.5 times greater than the world average. The number of patients in the majority of the houses in this district was more than one.

  2. Efficiency of personal dosimetry methods in vascular interventional radiology.

    PubMed

    Bacchim Neto, Fernando Antonio; Alves, Allan Felipe Fattori; Mascarenhas, Yvone Maria; Giacomini, Guilherme; Maués, Nadine Helena Pelegrino Bastos; Nicolucci, Patrícia; de Freitas, Carlos Clayton Macedo; Alvarez, Matheus; Pina, Diana Rodrigues de

    2017-05-01

    The aim of the present study was to determine the efficiency of six methods for calculate the effective dose (E) that is received by health professionals during vascular interventional procedures. We evaluated the efficiency of six methods that are currently used to estimate professionals' E, based on national and international recommendations for interventional radiology. Equivalent doses on the head, neck, chest, abdomen, feet, and hands of seven professionals were monitored during 50 vascular interventional radiology procedures. Professionals' E was calculated for each procedure according to six methods that are commonly employed internationally. To determine the best method, a more efficient E calculation method was used to determine the reference value (reference E) for comparison. The highest equivalent dose were found for the hands (0.34±0.93mSv). The two methods that are described by Brazilian regulations overestimated E by approximately 100% and 200%. The more efficient method was the one that is recommended by the United States National Council on Radiological Protection and Measurements (NCRP). The mean and median differences of this method relative to reference E were close to 0%, and its standard deviation was the lowest among the six methods. The present study showed that the most precise method was the one that is recommended by the NCRP, which uses two dosimeters (one over and one under protective aprons). The use of methods that employ at least two dosimeters are more efficient and provide better information regarding estimates of E and doses for shielded and unshielded regions. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Increasing smoke alarm operability through theory-based health education: a randomised trial

    PubMed Central

    Miller, Ted R; Bergen, Gwen; Ballesteros, Michael F; Bhattacharya, Soma; Gielen, Andrea Carlson; Sheppard, Monique S

    2015-01-01

    Background Although working smoke alarms halve deaths in residential fires, many households do not keep alarms operational. We tested whether theory-based education increases alarm operability. Methods Randomised multiarm trial, with a single arm randomly selected for use each day, in low-income neighbourhoods in Maryland, USA. Intervention arms: (1) Full Education combining a health belief module with a social-cognitive theory module that provided hands-on practice installing alarm batteries and using the alarm’s hush button; (2) Hands-on Practice social-cognitive module supplemented by typical fire department education; (3) Current Norm receiving typical fire department education only. Four hundred and thirty-six homes recruited through churches or by knocking on doors in 2005–2008. Followup visits checked alarm operability in 370 homes (85%) 1–3.5 years after installation. Main outcome measures: number of homes with working alarms defined as alarms with working batteries or hard-wired and number of working alarms per home. Regressions controlled for alarm status preintervention; demographics and beliefs about fire risks and alarm effectiveness. Results Homes in the Full Education and Practice arms were more likely to have a functioning smoke alarm at follow-up (OR=2.77, 95% CI 1.09 to 7.03) and had an average of 0.32 more working alarms per home (95% CI 0.09 to 0.56). Working alarms per home rose 16%. Full Education and Practice had similar effectiveness (p=0.97 on both outcome measures). Conclusions Without exceeding typical fire department installation time, installers can achieve greater smoke alarm operability. Hands-on practice is key. Two years after installation, for every three homes that received hands-on practice, one had an additional working alarm. Trial registration number http://www.clinicaltrials.gov number NCT00139126. PMID:25165090

  4. The Citizen Science Program "H2O SOS: Help Heal the Ocean—Student Operated Solutions: Operation Climate Change" teaches middle and high school students about ocean threats related to climate change through hands-on activities and learning experiences in the field. This is a continuation of the Program presented last year at the Poster Session.

    NASA Astrophysics Data System (ADS)

    Weiss, N. K.; Wood, J. H.

    2017-12-01

    TThe Citizen Science Program H2O SOS: Help Heal the Ocean—Student Operated Solutions: Operation Climate Change, teaches middle and high school students about ocean threats related to climate change through hands-on activities and learning experiences in the field. During each session (in-class or after-school as a club), students build an understanding about how climate change impacts our oceans using resources provided by ExplorOcean (hands-on activities, presentations, multi-media). Through a student leadership model, students present lessons to each other, interweaving a deep learning of science, 21st century technology, communication skills, and leadership. After participating in learning experiences and activities related to 6 key climate change concepts: 1) Introduction to climate change, 2) Increased sea temperatures, 3) Ocean acidification, 4) Sea level rise, 5) Feedback mechanisms, and 6) Innovative solutions. H2O SOS- Operation Climate change participants select one focus issue and use it to design a multi-pronged campaign to increase awareness about this issue in their local community. The campaign includes social media, an interactive activity, and a visual component. All participating clubs that meet participation and action goals earn a field trip to Ocean Quest where they dive deeper into their selected issue through hands-on activities, real-world investigations, and interviews or presentations with experts. In addition to self-selected opportunities to showcase their focus issue, teams will participate in one of several key events identified by Ocean Quest.

  5. Mentoring console improves collaboration and teaching in surgical robotics.

    PubMed

    Hanly, Eric J; Miller, Brian E; Kumar, Rajesh; Hasser, Christopher J; Coste-Maniere, Eve; Talamini, Mark A; Aurora, Alexander A; Schenkman, Noah S; Marohn, Michael R

    2006-10-01

    One of the most significant limitations of surgical robots has been their inability to allow multiple surgeons and surgeons-in-training to engage in collaborative control of robotic surgical instruments. We report the initial experience with a novel two-headed da Vinci surgical robot that has two collaborative modes: the "swap" mode allows two surgeons to simultaneously operate and actively swap control of the robot's four arms, and the "nudge" mode allows them to share control of two of the robot's arms. The utility of the mentoring console operating in its two collaborative modes was evaluated through a combination of dry laboratory exercises and animal laboratory surgery. The results from surgeon-resident collaborative performance of complex three-handed surgical tasks were compared to results from single-surgeon and single-resident performance. Statistical significance was determined using Student's t-test. Collaborative surgeon-resident swap control reduced the time to completion of complex three-handed surgical tasks by 25% compared to single-surgeon operation of a four-armed da Vinci (P < 0.01) and by 34% compared to single-resident operation (P < 0.001). While swap mode was found to be most helpful during parts of surgical procedures that require multiple hands (such as isolation and division of vessels), nudge mode was particularly useful for guiding a resident's hands during crucially precise steps of an operation (such as proper placement of stitches). The da Vinci mentoring console greatly facilitates surgeon collaboration during robotic surgery and improves the performance of complex surgical tasks. The mentoring console has the potential to improve resident participation in surgical robotics cases, enhance resident education in surgical training programs engaged in surgical robotics, and improve patient safety during robotic surgery.

  6. Transplantation of severed digits to forearm stump for restoration of partial hand function.

    PubMed

    Cheng, G L; Pan, D D; Qu, Z Y

    1985-10-01

    Three cases of mutilating injury of the distal end of the forearm, wrist, and palm treated by transplantation of severed digits to the forearm stump are reported. Follow-up examinations made at 1 year and 4 months to 31/2 years postoperatively revealed fair sensory and motor functions. The functional result is better than that obtained after Krukenberg's operation or prosthesis fitting, and is comparable to that of "hand" reconstruction by autotransplantation of toes. Since this procedure can fulfill the basic requirements of hand function by reconstruction, namely, good sensibility; basic motor functions of pinching, grasping, and powerful gripping; and acceptable outward appearance, and can be accomplished in a one-stage operation without sacrificing toes, it should be considered as first choice whenever a suitable case is encountered.

  7. Blinks, saccades, and fixation pauses during vigilance task performance. I., Time on task.

    DOT National Transportation Integrated Search

    1994-12-01

    In the future, operators of complex equipment will spend more time monitoring computer controlled devices rather than having hands on control of such equipment. The operator intervenes in system operation under "unusual" conditions or when there is a...

  8. Identifying the health risks from very low-dose sparsely ionizing radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dreyer, N.A.; Friedlander, E.

    1982-01-01

    The health risks from low-dose sparsely ionizing (low-LET) radiation have been the subject of continued debate. At present, quantitative estimates of risk are extremely uncertain due to the controversy surrounding both the dosimetry for A-bomb survivor data and the choice of mathematical models for extrapolating risk from high to low doses. Nevertheless, much can be learned about the nature of the health risks by reviewing the epidemiologic literature. We present a summary of diseases which have been associated with low-LET radiation (<1000 rad) in at least two independent studies, according to the mean cumulative organ dose at which the diseasemore » was observed. At organ doses of less than or equal to50 rad, the only diseases that have been reported consistently are thyroid cancer, salivary gland tumors, and leukemia. The first two diseases were observed in association with x-ray epilation of the scalp for tinea capitis, a therapy which is no longer employed. On the other hand, leukemia has been observed repeatedly to occur at cumulative doses of greater than or equal to30 rad low-LET radiation.« less

  9. [An Introduction to A Newly-developed "Acupuncture Needle Manipulation Training-evaluation System" Based on Optical Motion Capture Technique].

    PubMed

    Zhang, Ao; Yan, Xing-Ke; Liu, An-Guo

    2016-12-25

    In the present paper, the authors introduce a newly-developed "Acupuncture Needle Manipulation Training-evaluation System" based on optical motion capture technique. It is composed of two parts, sensor and software, and overcomes some shortages of mechanical motion capture technique. This device is able to analyze the data of operations of the pressing-hand and needle-insertion hand during acupuncture performance and its software contains personal computer (PC) version, Android version, and Internetwork Operating System (IOS) Apple version. It is competent in recording and analyzing information of any ope-rator's needling manipulations, and is quite helpful for teachers in teaching, training and examining students in clinical practice.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richter, Daena Kei

    On 6/26/2015 at 1445 in 894/136, a thermal battery (approximately the size of a commercial size C cell) experienced an unexpected failure following a routine test where the battery is activated. The failure occurred while a test operator was transferring the battery from the testing primary containment box to another containment box within the same room; initial indications are that the battery package ruptured after it went into thermal runaway which led to the operator receiving bruising to the palm of the hand from the pressure of the expulsion. The operator was wearing the prescribed PPE, which was safety glassesmore » and a high temperature glove on the hand that was holding the battery.« less

  11. Imidafenacin has no influence on learning in nucleus basalis of Meynert-lesioned rats.

    PubMed

    Yamazaki, Takanobu; Fukata, Ayako

    2013-12-01

    The prevalence of overactive bladder (OAB) and Alzheimer's disease (AD) increases with age, and much attention has been paid to the risk of cognitive impairment which may be induced by antimuscarinics used for OAB in patients with AD. Imidafenacin, an antimuscarinic agent for OAB treatment, has been reported not to affect learning in normal animals. However, under the condition in which sensitivity to learning impairment by antimuscarinics is increased, it remains unclear whether imidafenacin still does not impair the learning. Therefore, the influences of imidafenacin on passive avoidance response were investigated in sham-operated and nucleus basalis of Meynert (nbM)-lesioned rats and compared with oxybutynin hydrochloride and tolterodine tartrate. The learning-inhibitory doses of intravenous oxybutynin hydrochloride and tolterodine tartrate were 0.3 and 3 mg/kg in sham-operated rats and 0.1 and 1 mg/kg in nbM-lesioned rats, respectively. Thus, the learning impairments by those antimuscarinics were more sensitive in nbM-lesioned rats than in sham-operated rats. On the other hand, intravenous administration of imidafenacin had no influence on learning in either case of the rats. In normal rats, however, intracerebroventricular administration of imidafenacin impaired learning to the same degree as that of oxybutynin hydrochloride. Thus, the present study suggests that imidafenacin, unlike the other antimuscarinics used, has no significant risk of enhancing learning impairment even in models whose sensitivity to learning impairment by antimuscarinics is commonly increased, probably because of its low brain penetration.

  12. Severe palmar-plantar erythrodysesthesia and aplasia in an adult undergoing re-induction treatment with high-dose cytarabine for acute myelogenous leukemia: a possible drug interaction between posaconazole and cytarabine.

    PubMed

    Alzghari, Saeed K; Seago, Susan E; Cable, Christian T; Herrington, Jon D

    2017-09-01

    High-dose cytarabine is recommended for re-induction chemotherapy in patients less than 60 years of age with acute myelogenous leukemia. This case describes a patient receiving high-dose cytarabine for re-induction and subsequently developed tingling and numbness in her hands and feet followed by severe pain, swelling, and erythema consistent with a diagnosis of palmar-plantar erythrodysesthesia. Furthermore, the patient's hemoglobin, platelets, and neutrophils did not recover after over 30 days post high-dose cytarabine. The patient was concurrently receiving posaconazole for fungal prophylaxis which was initiated after the induction therapy. We speculate that posaconazole may inhibit the cytarabine efflux through P-glycoprotein inhibition leading to the patient's palmar-plantar erythrodysesthesia and subsequent aplasia. Future pharmacokinetic studies need to be conducted to ascertain if posaconazole does influence the pharmacokinetics of cytarabine.

  13. Effect of propranolol in head tremor: quantitative study following single-dose and sustained drug administration.

    PubMed

    Calzetti, S; Sasso, E; Negrotti, A; Baratti, M; Fava, R

    1992-12-01

    The effect of the beta-adrenoceptor antagonist propranolol has been investigated in nine patients suffering from isolated (six patients) or prominent (three patients) essential tremor of the head. In a double-blind, placebo-controlled study the tremorolytic efficacy of propranolol has been assessed by a quantitative accelerometric method after a single oral dose (120 mg) and following 2 weeks of sustained treatment with two different dosage regimens of the drug (120 and 240 mg daily). As compared with placebo, a significant reduction in tremor magnitude was found following a single oral dose but not on sustained administration of the beta-blocker at either dosage. The results suggest that the efficacy of sustained propranolol on isolated or prominent essential head tremor is less predictable and satisfactory than expected on the basis of the single-dose response, as compared with hand tremor.

  14. Tennessee Valley region study: potential year 2000 radiological dose to population resulting from nuclear facility operations. [Includes glossary

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    A companion report, DOE/ET-0064/1, presents a geographic, cultural, and demographic profile of the Tennessee Valley Region study area. This report describes the calculations of radionuclide release and transport and of the resultant dose to the regional population, assuming a projected installed capacity of 220,000 MW in the year 2000, of which 144,000 MW would be nuclear. All elements of the fuel cycle were assumed to be in operation. The radiological dose was calculated as a one-year dose based on ingestion of 35 different food types as well as for nine non-food pathways, and was reported as dose to the totalmore » body and for six specific organs for each of four age groups (infant, child, teen, and adult). Results indicate that the average individual would receive an incremental dose of 7 x 10/sup -4/ millirems in the year 2000 from the operation of nuclear facilities within and adjacent to the region, five orders of magnitude smaller than the dose from naturally occurring radiation in the area. The major contributor to dose was found to be tritium, and the most significant pathways were immersion in air, inhalation of air, transpiration of tritium (absorption through the skin), and exposure radionuclide-containing soil. 60 references.« less

  15. 46 CFR 197.420 - Operations manual.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... dive team. (b) The operations manual must be modified in writing when adaptation is required because of...) Hand-held power tools; (ii) Welding and burning equipment; and (iii) Explosives. specific diving mode...

  16. Breaking the rules? X-ray examination of hematopoietic stem cell grafts at international airports.

    PubMed

    Petzer, Andreas L; Speth, Hans-Georg; Hoflehner, Elisabeth; Clausen, Johannes; Nachbaur, David; Gastl, Günther; Gunsilius, Eberhard

    2002-06-15

    Hematopoietic stem cell grafts from unrelated donors are commonly transported by aircraft. They must not be subjected to x-rays during security checks, which may cause inconvenient discussions between the courier and the airport security staff. We exposed hematopoietic stem cells from mobilized peripheral blood to a widely used x-ray hand-luggage control system. Cell viability as well as growth in vitro of mature progenitor cells (colony-forming cells), primitive progenitor cells (long-term culture-initiating cells), and lymphocytes were not altered even after 10 passages through the hand-luggage control system. Thus, repeated exposure to the low radiation dose of hand-luggage control systems (1.5 +/- 0.6 microSv per exposure) seems to be harmless for hematopoietic stem cells, which should simplify the international transport of stem cell grafts.

  17. Prosthetic Hand For Holding Rods, Tools, And Handles

    NASA Technical Reports Server (NTRS)

    Belcher, Jewell G., Jr.; Vest, Thomas W.

    1995-01-01

    Prosthetic hand with quick-grip/quick-release lever broadens range of specialized functions available to lower-arm amputee by providing improved capabilities for gripping rods, tools, handles, and like. Includes two stationary lower fingers opposed by one pivoting upper finger. Lever operates in conjunction with attached bracket.

  18. Remifentanil in combination with ketamine versus remifentanil in spinal fusion surgery--a double blind study.

    PubMed

    Hadi, B A; Al Ramadani, R; Daas, R; Naylor, I; Zelkó, R

    2010-08-01

    This study is aimed at conducting a program for two different anesthetic methods used during a spinal fusion surgery to ensure better intra-operative hemodynamic stability and post-operative pain control. A prospective, randomized, double blind study in patients scheduled for spinal fusion surgery, who were randomly allocated to two groups, G1 and G2, (n = 15 per group), class I-II ASA, was carried out. Both groups received pre-operatively midazolam, followed intra-operatively by propofol, sevoflurane, atracurium, and either remifentanil infusion 0.2 microg/kg/min (G1), or the same dose of remifentanil infusion and low doses of ketamine infusion 1 microg/kg/min (G2) anesthetics, antidote medication and post-operative morphine doses. HR, MAP, vital signs, surgical bleeding, urine output, duration of surgery and duration of anesthesia were recorded. In a 24-h recovery period in a post-anesthesia care unit (PACU) the recovery time, the first pain score and analgesic requirements were measured. Intra-operative HR and arterial BP were significantly less (p < 0.05) in G1 as compared to G2. In the PACU the first pain scores were significantly less (p < 0.05) in G2 than in G1. The time for the first patient analgesia demand dose was greater in G2, as also morphine consumption which was greater in G1 than G2 (p < 0.05). Other results were the same. None of the patients had any adverse drug reaction. Adding low doses of ketamine hydrochloride could be a routine therapy to improve the hemodynamic stability and reduce the post-operative morphine consumption during spinal fusion surgery.

  19. Force Model for Control of Tendon Driven Hands

    NASA Technical Reports Server (NTRS)

    Pena, Edward; Thompson, David E.

    1997-01-01

    Knowing the tendon forces generated for a given task such as grasping via a model, an artificial hand can be controlled. A two-dimensional force model for the index finger was developed. This system is assumed to be in static equilibrium, therefore, the equations of equilibrium were applied at each joint. Constraint equations describing the tendon branch connectivity were used. Gaussian elimination was used to solve for the unknowns of the Linear system. Results from initial work on estimating tendon forces in post-operative hands during active motion therapy were discussed. The results are important for understanding the effects of hand position on tendon tension, elastic effects on tendon tension, and overall functional anatomy of the hand.

  20. Transcutaneous immunization via rapidly dissolvable microneedles protects against hand-foot-and-mouth disease caused by enterovirus 71.

    PubMed

    Zhu, Zhuangzhi; Ye, Xiaohua; Ku, Zhiqiang; Liu, Qingwei; Shen, Chaoyun; Luo, Huafei; Luan, Hansen; Zhang, Chenghao; Tian, Shaoqiong; Lim, CheeYen; Huang, Zhong; Wang, Hao

    2016-12-10

    Recent large outbreaks of hand-foot-and-mouth disease (HFMD) have seriously affected the health of young children. Enterovirus 71 (EV71) is the main causative agent of HFMD. Herein, for the first time, rapidly dissolvable microneedles (MNs) loaded with EV71 virus-like particles (VLPs) were evaluated whether they could induce robust immune responses that confer protection against EV71 infection. The characteristics of prepared MNs including hygroscopy, mechanical strength, insertion capacity, dissolution profile, skin irritation and storage stability were comprehensively assessed. EV71 VLPs remained morphologically stable during fabrication. The MNs made of sodium hyaluronate maintained their insertion ability for at least 3h even at a high relative humidity of 75%. With the aid of spring-operated applicator, EV71 MNs (approximately 500μm length) could be readily penetrated into the mouse skin in vivo, and then rapidly dissolved to release encapsulated antigen within 2min. Additionally, MNs induced slight erythema that disappeared within a few hours. More importantly, mouse immunization and virus challenge studies demonstrated that MNs immunization induced high level of antibody responses conferring full protection against lethal EV71 virus challenge that were comparable to conventional intramuscular injection, but with only 1/10th of the delivered antigen (dose sparing). Consequently, our rapidly dissolving MNs may present as an effective and promising transcutaneous immunization device for HFMD prophylaxis among children. Copyright © 2016 Elsevier B.V. All rights reserved.

Top