Manassakorn, Anita; Ishikawa, Hiroshi; Kim, Jong S.; Wollstein, Gadi; Bilonick, Richard A.; Kagemann, Larry; Gabriele, Michelle L.; Sung, Kyung Rim; Mumcuoglu, Tarkan; Duker, Jay S.; Fujimoto, James G.; Schuman, Joel S.
2009-01-01
Objective To determine the correspondence between optic disc margins evaluated using disc photography (DP) and optical coherence tomography (OCT). Methods From May 1, 2005, through November 10, 2005, 17 healthy volunteers (17 eyes) had raster scans (180 frames, 501 samplings per frame) centered on the optic disc taken with stereo-optic DP and high-speed ultrahigh-resolution OCT (hsUHR-OCT). Two image outputs were derived from the hsUHR-OCT data set: an en face hsUHR-OCT fundus image and a set of 180 frames of cross-sectional images. Three ophthalmologists independently and in a masked, randomized fashion marked the disc margin on the DP, hsUHR-OCT fundus, and cross-sectional images using custom software. Disc size (area and horizontal and vertical diameters) and location of the geometric disc center were compared among the 3 types of images. Results The hsUHR-OCT fundus image definition showed a significantly smaller disc size than the DP definition (P<.001, mixed-effects analysis). The hsUHR-OCT cross-sectional image definition showed a significantly larger disc size than the DP definition (P<.001). The geometric disc center location was similar among the 3 types of images except for the y-coordinate, which was significantly smaller in the hsUHR-OCT fundus images than in the DP images. Conclusion The optic disc margin as defined by hsUHR-OCT was significantly different than the margin defined by DP. PMID:18195219
High-Density Near-Field Optical Disc Recording
NASA Astrophysics Data System (ADS)
Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Ide, Naoki; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu
2005-05-01
We developed a high-density near-field optical recording disc system using a solid immersion lens. The near-field optical pick-up consists of a solid immersion lens with a numerical aperture of 1.84. The laser wavelength for recording is 405 nm. In order to realize the near-field optical recording disc, we used a phase-change recording media and a molded polycarbonate substrate. A clear eye pattern of 112 GB capacity with 160 nm track pitch and 50 nm bit length was observed. The equivalent areal density is 80.6 Gbit/in2. The bottom bit error rate of 3 tracks-write was 4.5× 10-5. The readout power margin and the recording power margin were ± 30.4% and ± 11.2%, respectively.
Avci, R; Yilmaz, S; Inan, U U; Kaderli, B; Kurt, M; Yalcinbayir, O; Yildiz, M; Yucel, A
2013-12-01
To evaluate the results of surgical treatment of maculopathy secondary to congenital optic pit anomaly with pars plana vitrectomy (PPV), endolaser to the temporal edge of the optic disc and C3F8 tamponade without internal limiting membrane (ILM) peeling. Thirteen eyes of 12 patients with serous macular detachment and/or macular retinoschisis secondary to congenital optic disc pit (ODP) were included in the study. All eyes underwent PPV, posterior hyaloid removal, endolaser photocoagulation on the temporal margin of the optic disc and 12% C3F8 gas tamponade. Anatomic success and functional outcome determined retrospectively by optical coherence tomography and measurement of best corrected visual acuity (BCVA), respectively were the main outcome parameters. Two lines or more improvement in BCVA was obtained in 11 eyes and 6 of these eyes had 20/40 or better BCVA at the final visit. Subretinal or intraretinal fluid was completely resorbed postoperatively in 12 eyes but a little intraretinal fluid persisted in one eye at the 16-month follow-up. Better visual improvement was observed in patients treated by earlier surgical intervention. PPV, C3F8 gas tamponade and endolaser to the optic disc margin without ILM peeling may yield favourable results in the treatment of ODP maculopathy.
Digital Timing Recovery for High Speed Optical Drives
NASA Astrophysics Data System (ADS)
Ko, Seok Jun; Kim, Pan Soo; Choi, Hyung Jin; Lee, Jae-Wook
2002-03-01
A new digital timing recovery scheme for the optical drive system is presented. By comparative simulations using digital versatile disc (DVD) patterns with marginal input conditions, the proposed algorithm shows enhanced performances in jitter variance and signal-to-noise ratio (SNR) margin by four times and 3 [dB], respectively.
Sharma, Ashish; Oakley, Jonathan D.; Schiffman, Joyce C.; Budenz, Donald L.; Anderson, Douglas R.
2010-01-01
OBJECTIVE To evaluate a new automated analysis of optic disc images obtained by spectral domain optical coherence tomography (SD-OCT). Areas of the optic disc, cup, and neural rim in SD-OCT images were compared with these areas from stereoscopic photographs, to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared. DESIGN Evaluation of diagnostic technology. PARTICIPANTS 119 healthy eyes, 23 eyes with glaucoma, and 7 suspect eyes METHODS Optic disc and cup margins were traced from stereoscopic photographs by three individuals independently. Optic disc margins and rim widths were determined automatically in SD-OCT. A subset of photographs was examined and traced a second time, and duplicate SD-OCT images were also analyzed. MAIN OUTCOME MEASUREMENTS Agreement among photograph readers, between duplicate readings, and between SD-OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square (RMS), and the standard deviation (SD) of the differences. RESULTS Optic disc areas tended to be slightly larger when judged in photographs than by SD-OCT, while cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between average photographic reading and SD-OCT, but only fair correlation of rim areas (0.4). The SD-OCT was highly reproducible (ICC of 0.96 to 0.99). Each reader was also consistent with himself on duplicate readings of 21 photographs (ICC 0.80 to 0.88 for rim area, 0.95 to 0.98 for all other measurements), but reproducibility was not as good as SD-OCT. Measurements derived from SD-OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other. CONCLUSIONS Designation of the cup and optic disc boundaries by an automated analysis of SD-OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of different landmarks typically made the designation of the optic disc size somewhat smaller in the automated analysis. There was better repeatability among measurements from SD-OCT than from among readers of photographs. The repeatability of automated measurement of SD-OCT images is promising for use both in diagnosis and in monitoring of progression. PMID:21397334
Comparison of optical coherence tomography and fundus photography for measuring the optic disc size.
Neubauer, Aljoscha S; Krieglstein, Tina R; Chryssafis, Christos; Thiel, Martin; Kampik, Anselm
2006-01-01
To assess the agreement and repeatability of optic nerve head (ONH) size measurements by optical coherence tomography (OCT) as compared to conventional planimetry of fundus photographs in normal eyes. For comparison with planimetry the absolute size of the ONH of 25 eyes from 25 normal subjects were measured by both OCT and digital fundus photography (Zeiss FF camera 450). Repeatability of automated Stratus OCT measurements were investigated by repeatedly measuring the optic disc in five normal subjects. Mean disc size was 1763 +/- 186 vertically and 1632 +/- 160 microm horizontally on planimetry. On OCT, values of 1772 +/- 317 microm vertically (p = 0.82) and a significantly smaller horizontal diameter of 1492 +/- 302 microm (p = 0.04) were obtained. The 95% limits of agreement were (-546 microm; +527 microm) for vertical and (-502 microm; +782 microm) for horizontal planimetric compared to OCT measurements. In some cases large discrepancies existed. Repeatability of automatic measurements of the optic disc by OCT was moderately good with intra-class correlation coefficients (ICC) of 0.78 horizontally and 0.83 vertically. The coefficient of repeatability indicating instrument precision was 80 microm for horizontal and 168 microm for vertical measurements. OCT can be used to determine optic disc margins in moderate agreement with planimetry in normal subjects. However, in some cases significant disagreement with photographic assessment may occur making manual inspection advisable. Automatic disc detection by OCT is moderately repeatable.
Optic nerve involvement in a borderline lepromatous leprosy patient on multidrug therapy.
Prabha, Neel; Mahajan, Vikram K; Sharma, Surinder K; Sharma, Vikas; Chauhan, Pushpinder S; Mehta, Karaninder S; Abhinav, C; Khatri, Gaytri; Chander, Bal; Tuli, Rajiv
2013-12-01
Amidst the plethora of ocular complications of leprosy, involvement of the posterior segment or optic nerve is extremely rare. The mechanism of optic neuritis in leprosy is poorly understood. A 47 year-old man presented with a single lesion suggestive of mid-borderline (BB) leprosy over left periorbital region; the histology showed borderline lepromatous (BL) leprosy with a BI of 3+. After initial improvement with WHO MDT-MB and prednisolone (40 mg/d) he developed sudden and painless diminished vision in the left eye, about 3 weeks later. His visual acuity was 6/9 in the left and 6/6 in the right eye, and there was left optic disc edema, hyperemia and blurred disc margins. Treatment with prednisolone (60 mg/d) along with WHO MDT-MB continued. A month later he returned with painless diminished vision in the other eye as well. Visual acuity was 6/6 in the right and 6/12 in the left eye, and there was right optic disc edema and left optic disc atrophy. CT of the head and MRI of the brain were normal. Inflammatory edema of the orbital connective tissue or other surrounding structures, or direct infiltration of vasa nervosa with resultant vascular occlusion leading to optic nerve ischemia, seems the most plausible explanation of optic nerve involvement in this case.
Kee, Nathaniel Dylan; Owocki, Stanley; Sundqvist, J O
2016-05-21
The extreme luminosities of massive, hot OB stars drive strong stellar winds through line-scattering of the star's UV continuum radiation. For OB stars with an orbiting circumstellar disc, we explore here the effect of such line-scattering in driving an ablation of material from the disc's surface layers, with initial focus on the marginally optically thin decretion discs of classical Oe and Be stars. For this we apply a multidimensional radiation-hydrodynamics code that assumes simple optically thin ray tracing for the stellar continuum, but uses a multiray Sobolev treatment of the line transfer; this fully accounts for the efficient driving by non-radial rays, due to desaturation of line-absorption by velocity gradients associated with the Keplerian shear in the disc. Results show a dense, intermediate-speed surface ablation, consistent with the strong, blueshifted absorption of UV wind lines seen in Be shell stars that are observed from near the disc plane. A key overall result is that, after an initial adjustment to the introduction of the disc, the asymptotic disc destruction rate is typically just an order-unity factor times the stellar wind mass-loss rate. For optically thin Be discs, this leads to a disc destruction time of order months to years, consistent with observationally inferred disc decay times. The much stronger radiative forces of O stars reduce this time to order days, making it more difficult for decretion processes to sustain a disc in earlier spectral types, and so providing a natural explanation for the relative rarity of Oe stars in the Galaxy. Moreover, the decrease in line-driving at lower metallicity implies both a reduction in the winds that help spin-down stars from near-critical rotation, and a reduction in the ablation of any decretion disc; together these provide a natural explanation for the higher fraction of classical Be stars, as well as the presence of Oe stars, in the lower metallicity Magellanic Clouds. We conclude with a discussion of future extensions to study line-driven ablation of denser, optically thick, accretion discs of pre-main-sequence massive stars.
Kee, Nathaniel Dylan; Owocki, Stanley; Sundqvist, J. O.
2016-01-01
The extreme luminosities of massive, hot OB stars drive strong stellar winds through line-scattering of the star's UV continuum radiation. For OB stars with an orbiting circumstellar disc, we explore here the effect of such line-scattering in driving an ablation of material from the disc's surface layers, with initial focus on the marginally optically thin decretion discs of classical Oe and Be stars. For this we apply a multidimensional radiation-hydrodynamics code that assumes simple optically thin ray tracing for the stellar continuum, but uses a multiray Sobolev treatment of the line transfer; this fully accounts for the efficient driving by non-radial rays, due to desaturation of line-absorption by velocity gradients associated with the Keplerian shear in the disc. Results show a dense, intermediate-speed surface ablation, consistent with the strong, blueshifted absorption of UV wind lines seen in Be shell stars that are observed from near the disc plane. A key overall result is that, after an initial adjustment to the introduction of the disc, the asymptotic disc destruction rate is typically just an order-unity factor times the stellar wind mass-loss rate. For optically thin Be discs, this leads to a disc destruction time of order months to years, consistent with observationally inferred disc decay times. The much stronger radiative forces of O stars reduce this time to order days, making it more difficult for decretion processes to sustain a disc in earlier spectral types, and so providing a natural explanation for the relative rarity of Oe stars in the Galaxy. Moreover, the decrease in line-driving at lower metallicity implies both a reduction in the winds that help spin-down stars from near-critical rotation, and a reduction in the ablation of any decretion disc; together these provide a natural explanation for the higher fraction of classical Be stars, as well as the presence of Oe stars, in the lower metallicity Magellanic Clouds. We conclude with a discussion of future extensions to study line-driven ablation of denser, optically thick, accretion discs of pre-main-sequence massive stars. PMID:27346978
Optical Coherence Tomography Angiography of Retinal Cavernous Hemangioma.
Pierro, Luisa; Marchese, Alessandro; Gagliardi, Marco; Bandello, Francesco
2017-08-01
Retinal cavernous hemangioma is a rare, benign, retinal tumor characterized by angiomatous proliferation of vessels within the inner retina or the optic disc.1 Here we report a case of retinal cavernous hemangioma on the margin of the optic disc in the right eye of a 61-year-old asymptomatic female. The lesion was studied with multimodal imaging which included structural optical coherence tomography, fluorescein angiography, blue fundus auto-fluorescence, optical coherence tomography angiography (OCTA) (DRI OCT Triton; Topcon, Tokyo, Japan) and visual field examination. Blood circulation inside retinal cavernous hemangioma lesion is typically low-stagnant.2 However, OCTA demonstrated blood flow inside the lesion, illustrating its vascular circulation.3 Visual field was within the normal limits, except from a slight enlargement of the blind spot. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:684-685.]. Copyright 2017, SLACK Incorporated.
On marginally resolved objects in optical interferometry
NASA Astrophysics Data System (ADS)
Lachaume, R.
2003-03-01
With the present and soon-to-be breakthrough of optical interferometry, countless objects shall be within reach of interferometers; yet, most of them are expected to remain only marginally resolved with hectometric baselines. In this paper, we tackle the problem of deriving the properties of a marginally resolved object from its optical visibilities. We show that they depend on the moments of flux distribution of the object: centre, mean angular size, asymmetry, and curtosis. We also point out that the visibility amplitude is a second-order phenomenon, whereas the phase is a combination of a first-order term, giving the location of the photocentre, and a third-order term, more difficult to detect than the visibility amplitude, giving an asymmetry coefficient of the object. We then demonstrate that optical visibilities are not a good model constraint while the object stays marginally resolved, unless observations are carried out at different wavelengths. Finally, we show an application of this formalism to circumstellar discs.
Zangwill, Linda M; Chan, Kwokleung; Bowd, Christopher; Hao, Jicuang; Lee, Te-Won; Weinreb, Robert N; Sejnowski, Terrence J; Goldbaum, Michael H
2004-09-01
To determine whether topographical measurements of the parapapillary region analyzed by machine learning classifiers can detect early to moderate glaucoma better than similarly processed measurements obtained within the disc margin and to improve methods for optimization of machine learning classifier feature selection. One eye of each of 95 patients with early to moderate glaucomatous visual field damage and of each of 135 normal subjects older than 40 years participating in the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS) were included. Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Dossenheim, Germany) mean height contour was measured in 36 equal sectors, both along the disc margin and in the parapapillary region (at a mean contour line radius of 1.7 mm). Each sector was evaluated individually and in combination with other sectors. Gaussian support vector machine (SVM) learning classifiers were used to interpret HRT sector measurements along the disc margin and in the parapapillary region, to differentiate between eyes with normal and glaucomatous visual fields and to compare the results with global and regional HRT parameter measurements. The area under the receiver operating characteristic (ROC) curve was used to measure diagnostic performance of the HRT parameters and to evaluate the cross-validation strategies and forward selection and backward elimination optimization techniques that were used to generate the reduced feature sets. The area under the ROC curve for mean height contour of the 36 sectors along the disc margin was larger than that for the mean height contour in the parapapillary region (0.97 and 0.85, respectively). Of the 36 individual sectors along the disc margin, those in the inferior region between 240 degrees and 300 degrees, had the largest area under the ROC curve (0.85-0.91). With SVM Gaussian techniques, the regional parameters showed the best ability to discriminate between normal eyes and eyes with glaucomatous visual field damage, followed by the global parameters, mean height contour measures along the disc margin, and mean height contour measures in the parapapillary region. The area under the ROC curve was 0.98, 0.94, 0.93, and 0.85, respectively. Cross-validation and optimization techniques demonstrated that good discrimination (99% of peak area under the ROC curve) can be obtained with a reduced number of HRT parameters. Mean height contour measurements along the disc margin discriminated between normal and glaucomatous eyes better than measurements obtained in the parapapillary region. Copyright Association for Research in Vision and Ophthalmology
Zangwill, Linda M.; Chan, Kwokleung; Bowd, Christopher; Hao, Jicuang; Lee, Te-Won; Weinreb, Robert N.; Sejnowski, Terrence J.; Goldbaum, Michael H.
2010-01-01
Purpose To determine whether topographical measurements of the parapapillary region analyzed by machine learning classifiers can detect early to moderate glaucoma better than similarly processed measurements obtained within the disc margin and to improve methods for optimization of machine learning classifier feature selection. Methods One eye of each of 95 patients with early to moderate glaucomatous visual field damage and of each of 135 normal subjects older than 40 years participating in the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS) were included. Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Dossenheim, Germany) mean height contour was measured in 36 equal sectors, both along the disc margin and in the parapapillary region (at a mean contour line radius of 1.7 mm). Each sector was evaluated individually and in combination with other sectors. Gaussian support vector machine (SVM) learning classifiers were used to interpret HRT sector measurements along the disc margin and in the parapapillary region, to differentiate between eyes with normal and glaucomatous visual fields and to compare the results with global and regional HRT parameter measurements. The area under the receiver operating characteristic (ROC) curve was used to measure diagnostic performance of the HRT parameters and to evaluate the cross-validation strategies and forward selection and backward elimination optimization techniques that were used to generate the reduced feature sets. Results The area under the ROC curve for mean height contour of the 36 sectors along the disc margin was larger than that for the mean height contour in the parapapillary region (0.97 and 0.85, respectively). Of the 36 individual sectors along the disc margin, those in the inferior region between 240° and 300°, had the largest area under the ROC curve (0.85–0.91). With SVM Gaussian techniques, the regional parameters showed the best ability to discriminate between normal eyes and eyes with glaucomatous visual field damage, followed by the global parameters, mean height contour measures along the disc margin, and mean height contour measures in the parapapillary region. The area under the ROC curve was 0.98, 0.94, 0.93, and 0.85, respectively. Cross-validation and optimization techniques demonstrated that good discrimination (99% of peak area under the ROC curve) can be obtained with a reduced number of HRT parameters. Conclusions Mean height contour measurements along the disc margin discriminated between normal and glaucomatous eyes better than measurements obtained in the parapapillary region. PMID:15326133
Nakanishi, Hideo; Suda, Kenji; Yoshikawa, Munemitsu; Akagi, Tadamichi; Kameda, Takanori; Ikeda, Hanako Ohashi; Yokota, Satoshi; Kurimoto, Yasuo; Tsujikawa, Akitaka
2018-03-01
To examine the morphology of Bruch's membrane opening (BMO), optic disc, and peripapillary atrophy (PPA) by scanning laser ophthalmoscopy (SLO) and spectral-domain optical coherence tomography (SD-OCT), and to determine their association with the axial length and visual field defects. This was a cross-sectional study of 94 eyes of 56 subjects; 77 eyes were diagnosed with primary open-angle glaucoma and 17 eyes as normal. The margins of the optic disc were determined in the SLO images, and that of the BMO in the SD-OCT images. The ovality and area of the BMO and the optic disc were measured. The beta and gamma-PPA areas were also measured. The association of each parameter with the axial length and the mean deviation (MD) of the visual field tests was determined by generalized estimating equations (GEEs). The optic disc ovality was associated with the axial length and the MD (β = -0.47, P = 7.6 × 10 -4 and β = 0.12, P = 0.040). The BMO ovality was not significantly associated with the axial length and the MD. The BMO area was associated with the axial length (β = 0.30, P = 0.029). A larger BMO area was associated with a thinner BMO-based neuroretinal rim width (BMO-MRW) after adjustments for the MD (β = -0.30, P = 2.1 × 10 -4 ). The beta- and gamma-PPA areas were associated with the axial length (β = 0.50, P = 7.4 × 10 -5 and β = 0.62, P = 4.2 × 10 -6 ). The optic disc ovality was associated with both the axial length and MD, whereas BMO ovality was not. Attention should be paid to the influence of the axial length-related enlargement of the BMO.
Moreira Neto, Carlos Augusto; Moreira Junior, Carlos Augusto
2013-01-01
To evaluate 5 patients with serous macular detachment due to optic disc pit that were submitted to pars plana vitrectomy and were followed for at least 7 years. Patients were submitted to pars plana vitrectomy, posterior hyaloid removal, autologous serum injection and gas-fluid exchange, without laser photocoagulation, and were evaluated pre and post-operatively with visual acuity and Amsler grid testing, retinography, and recently, with autofluorescence imaging and high resolution OCT. All 5 eyes improved visual acuity significantly following the surgical procedure maintaining good vision throughout the follow-up period. Mean pre-operative visual acuity was 20/400 and final visual acuity was 20/27 with a mean follow-up time of 13.6 years. No recurrences of serous detachments were observed. OCT examinations demonstrated an attached retina up to the margin of the pit. Serous macular detachments due to optic disc pits were adequately treated with pars plana vitrectomy and gas fluid exchange, without the need for laser photocoagulation, maintaining excellent visual results for a long period of time.
Malik, Rizwan; Belliveau, Anne C; Sharpe, Glen P; Shuba, Lesya M; Chauhan, Balwantray C; Nicolela, Marcelo T
2016-06-01
Ruling out glaucoma in myopic eyes often poses a diagnostic challenge because of atypical optic disc morphology and visual field defects that can mimic glaucoma. We determined whether neuroretinal rim assessment based on Bruch's membrane opening (BMO), rather than conventional optic disc margin (DM)-based assessment or retinal nerve fiber layer (RNFL) thickness, yielded higher diagnostic accuracy in myopic patients with glaucoma. Case-control, cross-sectional study. Myopic patients with glaucoma (n = 56) and myopic normal controls (n = 74). Myopic subjects with refraction error greater than -2 diopters (D) (spherical equivalent) and typical myopic optic disc morphology, with and without glaucoma, were recruited from a glaucoma clinic and a local optometry practice. The final classification of myopic glaucoma or myopic control was based on consensus assessment by 3 clinicians of visual fields and optic disc photographs. Participants underwent imaging with confocal scanning laser tomography for measurement of DM rim area (DM-RA) and with spectral domain optical coherence tomography (SD OCT) for quantification of a BMO-based neuroretinal rim parameter, minimum rim width (BMO-MRW), and RNFL thickness. Sensitivity of DM-RA, BMO-MRW, and RNFL thickness at a fixed specificity of 90% and partial area under the curves (pAUCs) for global and sectoral parameters for specificities ≥90%. Sensitivities at 90% specificity were 30% for DM-RA and 71% for both BMO-MRW and RNFL thickness. The pAUC was higher for the BMO-MRW compared with DM-RA (P < 0.001), but similar to RNFL thickness (P > 0.5). Sectoral values of BMO-MRW tended to have a higher, but nonsignificant, pAUC across all sectors compared with RNFL thickness. Bruch's membrane opening MRW is more sensitive than DM-RA and similar to RNFL thickness for the identification of glaucoma in myopic eyes and offers a valuable diagnostic tool for patients with glaucoma with myopic optic discs. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Guo, Yin; Liu, Li Juan; Tang, Ping; Feng, Yi; Lv, Yan Yun; Wu, Min; Xu, Liang; Jonas, Jost B
2018-03-01
To assess the development and enlargement of the parapapillary gamma zone in school children. This school-based prospective longitudinal study included Chinese children attending grade 1 in 2011 and returning for yearly follow-up examinations until 2016. These examinations consisted of a comprehensive ocular examination with biometry and color fundus photographs. The parents underwent a standardized interview. The parapapillary gamma zone was defined as the area with visible sclera at the temporal optic disc margin, and the optic disc itself was measured on fundus photographs. The study included 294 children (mean age in 2016, 11.4 ± 0.5 years [range, 10-13 years]; mean axial length, 24.1 ± 1.1 mm [range, 21.13-27.29 mm]). In multivariate analysis, larger increases in the gamma zone area during the study period were correlated (coefficient of determination for bivariate analysis [r2], r2 = 0.69) with larger increases in the vertical-to-horizontal disc diameter ratios (P < 0.001; standardized regression coefficient beta [beta], 0.53; nonstandardized regression coefficient B [B], 4.05; 95% confidence intervals [CI], 3.37-4.73), larger axial elongation (P < 0.001; beta, 0.32; B, 0.37; 95% CI, 0.26-0.47), a larger vertical disc diameter at baseline (P < 0.001; beta, 0.22; B, 0.98; 95% CI, 0.62-1.33), a larger gamma zone area at baseline (P < 0.001; beta, 0.14; B, 0.41; 95% CI, 0.17-0.64), and more time spent indoors studying (P = 0.015; beta, 0.10; B, 0.09; 95% CI, 0.02-0.17). The development and enlargement of the gamma zone in the temporal parapapillary region were associated with an optic disc rotation around the vertical disc axis as indicated by an increasing vertical-to-horizontal disc diameter ratio. These morphologic findings fit with the notion of a backward pull of the temporal peripapillary sclera through the optic nerve dura mater in axially elongated eyes.
[Atypical optic neuritis in systemic lupus erythematosus (SLE)].
Eckstein, A; Kötter, I; Wilhelm, H
1995-11-01
A 67-year-old woman experienced acute unilateral visual loss accompanied by pain with eye movements. There was a marked relative afferent pupillary defect and a nerve fiber bundle defect in the upper half of the visual field. Optic discs were normal. After 4 days vision worsened to motion detection and only a temporal island was left in the visual field. The optic disc margin was blurred. Since thirty years she had been suffering from renal insufficiency. Immunoserologic examination revealed elevated ANA and DS-DNA antibody titers. An optic neuritis in systemic lupus erythematosus was diagnosed, which is called atopic, because of its association to a systemic disease and the old age of the patient. The patient was treated with 100 mg prednisolone/day, slowly tapered. Within 6 weeks visual acuity improved to 0.6 and visual field normalized except for a small nerve fiber bundle defect. Autoimmune optic neuritis often responds to treatment with corticosteroids. Early onset of treatment is important. Immunopathologic examinations are an important diagnostic tool in atopic optic neuritis. Their results may even have consequences for the treatment of the underlying disease.
Theodossiadis, G P; Panopoulos, M; Kollia, A K; Georgopoulos, G
1992-08-01
During the period 1970-87 we evaluated the changes of the optic disc, peripapillary area, detached macula and visual acuity in 16 cases with congenital pit of the optic nerve and macular detachment. The study revealed in 9 of the 16 cases (56%) an increase of the dimension of the pit or changes in its color, findings which were directly related to the duration of the macular detachment. Chorioretinal scarring, pigment migration, or both, were also noted mainly at the temporal margin of optic disc. In 5/16 cases we found during the follow-up an extension of macular elevation. In altogether 10 out of 16 cases the retinal elevation covered the larger portion of the mid-periphery temporally. In 7/16 cases the final visual acuity remained unchanged, in 9/16 cases deteriorated. The difference, however, in the latter 9 cases between initial and final visual acuity was negligible. During the follow-up period deterioration of the visual fields was also noted.
NASA Astrophysics Data System (ADS)
Kajiwara, Yoshiyuki; Shiraishi, Junya; Kobayashi, Shoei; Yamagami, Tamotsu
2009-03-01
A digital phase-locked loop (PLL) with a linearly constrained adaptive filter (LCAF) has been studied for higher-linear-density optical discs. LCAF has been implemented before an interpolated timing recovery (ITR) PLL unit in order to improve the quality of phase error calculation by using an adaptively equalized partial response (PR) signal. Coefficient update of an asynchronous sampled adaptive FIR filter with a least-mean-square (LMS) algorithm has been constrained by a projection matrix in order to suppress the phase shift of the tap coefficients of the adaptive filter. We have developed projection matrices that are suitable for Blu-ray disc (BD) drive systems by numerical simulation. Results have shown the properties of the projection matrices. Then, we have designed the read channel system of the ITR PLL with an LCAF model on the FPGA board for experiments. Results have shown that the LCAF improves the tilt margins of 30 gigabytes (GB) recordable BD (BD-R) and 33 GB BD read-only memory (BD-ROM) with a sufficient LMS adaptation stability.
Segmentation of optic disc and optic cup in retinal fundus images using shape regression.
Sedai, Suman; Roy, Pallab K; Mahapatra, Dwarikanath; Garnavi, Rahil
2016-08-01
Glaucoma is one of the leading cause of blindness. The manual examination of optic cup and disc is a standard procedure used for detecting glaucoma. This paper presents a fully automatic regression based method which accurately segments optic cup and disc in retinal colour fundus image. First, we roughly segment optic disc using circular hough transform. The approximated optic disc is then used to compute the initial optic disc and cup shapes. We propose a robust and efficient cascaded shape regression method which iteratively learns the final shape of the optic cup and disc from a given initial shape. Gradient boosted regression trees are employed to learn each regressor in the cascade. A novel data augmentation approach is proposed to improve the regressors performance by generating synthetic training data. The proposed optic cup and disc segmentation method is applied on an image set of 50 patients and demonstrate high segmentation accuracy for optic cup and disc with dice metric of 0.95 and 0.85 respectively. Comparative study shows that our proposed method outperforms state of the art optic cup and disc segmentation methods.
Sánchez Pérez, A; Honrubia López, F M; Larrosa Poves, J M; Polo Llorens, V; Melcon Sánchez-Frieras, B
2001-09-01
To develop a lens planimetry technique for the optic disc using AutoCAD. To determine variability magnitude of the optic disc morphological measurements. We employed AutoCAD R.14.0 Autodesk: image acquisition, contour delimitation by multiple lines fitting or ellipse adjustment, image sectorialization and measurements quantification (optic disc and excavation, vertical diameters, optic disc area, excavation area, neuroretinal sector area and Beta atrophy area). Intraimage or operator and interimage o total reproducibility was studied by coefficient of variability (CV) (n=10) in normal and myopic optic discs. This technique allows to obtain optic disc measurement in 5 to 10 minutes time. Total or interimage variability of measurements introduced by one observer presents CV range from 1.18-4.42. Operator or intraimage measurement presents CV range from 0.30-4.21. Optic disc contour delimitation by ellipse adjustment achieved better reproducibility results than multiple lines adjustment in all measurements. Computer assisted AutoCAD planimetry is an interactive method to analyse the optic disc, feasible to incorporate to clinical practice. Reproducibility results are comparable to other analyzers in quantification optic disc morphology. Ellipse adjustment improves results in optic disc contours delimitation.
Chang, Melinda Y.; Pineles, Stacy L.
2016-01-01
Optic disc drusen occur in 0.4% of children and consist of acellular intracellular and extracellular deposits that often become calcified over time. They are typically buried early in life and generally become superficial, and therefore visible, later in childhood, at the average age of 12 years. Their main clinical significance lies in the ability of optic disc drusen, particularly when buried, to simulate true optic disc edema. Misdiagnosing drusen as true disc edema may lead to an invasive and unnecessary workup for elevated intracranial pressure. Ancillary testing, including ultrasonography, fluorescein angiography, fundus autofluorescence, and optical coherence tomography, may aid in the correct diagnosis of optic disc drusen. Complications of optic disc drusen in children include visual field defects, hemorrhages, choroidal neovascular membrane, non-arteritic anterior ischemic optic neuropathy, and retinal vascular occlusions. Treatment options for these complications include ocular hypotensive agents for visual field defects and intravitreal anti-vascular endothelial growth factor (anti-VEGF) agents for choroidal neovascular membranes. In most cases, however, children with optic disc drusen can be managed by observation with serial examinations and visual field testing, once true optic disc edema has been excluded. PMID:27033945
Anomalous optic discs in a patient with a Dandy-Walker cyst.
Orcutt, J C; Bunt, A H
1982-03-01
A 19-month-old female infant with a Dandy-Walker cyst had anomalous optic discs, each of which appeared to divide to form an accessory optic nerve. The discs probably lie within the spectrum of anomalous discs including optic nerve aplasia and hypoplasia, megallopapillae, morning glory disc, optic disc dysplasia, and optic nerve colobomas. The association of anomalous optic discs with a Dandy-Walker cyst has not been previously recognized. The ocular and brain malformations in this patient likely occurred during the fourth to eighth week of gestation, when the retinal ganglion cell axons were penetrating the optic nerve, and the rhombic lips were enlarging in early cerebellar development. The etiology of these anomalies is not known; however, teratogens, sporadic events, and genetic disorders should be considered.
Bilateral optic disc drusen mimicking papilledema.
Sahin, Alparslan; Cingü, Abdullah Kürşat; Ari, Seyhmus; Cinar, Yasin; Caça, Ihsan
2012-06-01
Optic disc drusen, which are calcified deposits that form anterior to the lamina cribrosa in the optic nerve, may mimic papilledema. We report herein three cases referred to us with suspicion of disc swelling and papilledema. Following ophthalmologic evaluation with B-scan ultrasound, red-free fundus photography, and computed tomography, the diagnosis of papilledema was excluded in all cases and optic disc drusen was diagnosed. Clinical suspicion of optic disc drusen in cases presenting with swelling of the optic nerve head is important in order to avoid unnecessary interventions and anxiety. The reported cases highlight the commonly encountered clinical presentations and the practical aspects of diagnosis and management of optic disc drusen.
Enhancement of Speed Margins for 16× Digital Versatile Disc-Random Access Memory
NASA Astrophysics Data System (ADS)
Watanabe, Koichi; Minemura, Hiroyuki; Miyamoto, Makoto; Iimura, Makoto
2006-02-01
We have evaluated the speed margins of write/read 16× digital versatile disc-random access memory (DVD-RAM) test discs using write strategies for 6--16× constant angular velocity (CAV) control. Our approach is to determine the writing parameters for the middle zones by interpolating the zone numbers. Using this interpolation strategy, we successfully obtained overwrite jitter values of less than 8% and bit error rates of less than 10-5 in 6--16× DVD-RAM. Moreover, we confirmed that the speed margins were ± 20% for a 6--16× CAV.
Bilateral Optic Disc Drusen Mimicking Papilledema
Cingü, Abdullah Kürşat; Ari, Şeyhmus; Çinar, Yasin; Çaça, İhsan
2012-01-01
Background Optic disc drusen, which are calcified deposits that form anterior to the lamina cribrosa in the optic nerve, may mimic papilledema. Case Report We report herein three cases referred to us with suspicion of disc swelling and papilledema. Following ophthalmologic evaluation with B-scan ultrasound, red-free fundus photography, and computed tomography, the diagnosis of papilledema was excluded in all cases and optic disc drusen was diagnosed. Conclusions Clinical suspicion of optic disc drusen in cases presenting with swelling of the optic nerve head is important in order to avoid unnecessary interventions and anxiety. The reported cases highlight the commonly encountered clinical presentations and the practical aspects of diagnosis and management of optic disc drusen. PMID:22787500
Cennamo, Gilda; Rossi, Claudia; Ruggiero, Pasquale; de Crecchio, Giuseppe; Cennamo, Giovanni
2017-04-01
To evaluate the radial peripapillary capillary network with optical coherence tomography angiography (angio-OCT) in morning glory syndrome (MGS), optic disc colobomas, and optic disc pits, and to explore possible correlations between the neural vascular structure and the pathogenesis of congenital optic disc anomalies. Prospective observational comparative case series. Fifteen eyes of 15 patients with congenital optic disc anomalies were enrolled in this study. All patients underwent angio-OCT. The scans were centered on optic discs. The mean age at presentation was 33 years (range: 19-50 years). Congenital optic disc anomalies were identified in all 15 eyes. Three eyes had the characteristic funduscopic signs of MGS, and angio-OCT scans of the peripapillary retina revealed a dense microvascular network. Optic disc colobomas were found in 5 eyes, and the characteristic funduscopic signs of optic pits were found in 7 eyes. Angio-OCT showed the absence of a radial peripapillary microvascular network in these 12 eyes. The finding that angio-OCT scans confirmed the presence of a peripapillary microvascular network only in MGS cases supports the hypothesis that a primary neuroectodermal abnormality and a secondary mesenchymal abnormality leads to MGS. Angio-OCT is a safe, rapid imaging technique that could shed light on the pathogenesis of rare diseases of the optic disc. Copyright © 2016 Elsevier Inc. All rights reserved.
Carreño, Ester; Guly, Catherine M; Chilov, Michael; Hinchcliffe, Annie; Arostegui, Juan I; Lee, Richard W J; Dick, Andrew D; Ramanan, Athimalaipet V
2015-05-01
To determine whether patients with juvenile systemic granulomatous disease (JSGD) (Blau syndrome) and uveitis have a characteristic ocular phenotype. Clinical and imaging data were collected retrospectively from patients attending the Regional Combined Paediatric Rheumatology and Ocular Inflammatory Service, Bristol Eye Hospital. General demographic information, laterality of the uveitis, age at onset, anatomical classification and course of the uveitis, clinical phenotype and specific NOD2 mutation were recorded for each patient. Seventeen eyes from nine patients (five males; four females) were included in the study. Mean age at the disease onset was 15 months, range 1-84 months. Eight patients had bilateral uveitis. Anterior uveitis was present in five eyes, intermediate uveitis in two eyes, and there were 10 eyes with panuveitis, manifesting as multifocal choroiditis. Appearance of optic disc included indistinct disc margins in six eyes, optic nerve head pallor in six eyes, optic disc vessel sheathing in four eyes, and there was peripapillary hypo/hyperpigmentation in 13 eyes accompanied with characteristic peripapillary nodular excrescences. Among NOD2 mutations, the p.R334W was the most commonly detected (n: four cases), and three patients carried novel variants, the p.E338D and p.D390V variants in one patient, and the p.H520Y and p.Q809K variants in two different patients. Chronic bilateral panuveitis and a nodular peripapillary appearance in childhood onset uveitis are characteristic features of JSGD, which support the need for an appropriate genetic NOD2 analysis. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Optic Disc and Optic Cup Segmentation Methodologies for Glaucoma Image Detection: A Survey
Almazroa, Ahmed; Burman, Ritambhar; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan
2015-01-01
Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed. PMID:26688751
The Location of the Deepest Point of the Eyeball Determines the Optic Disc Configuration.
Kim, Yong Chan; Jung, Younhea; Park, Hae-Young Lopilly; Park, Chan Kee
2017-07-19
Tilted and rotated appearances are hallmarks of the myopic optic disc. As the eyeball grows axially, the posterior pole elongates not only globally but in a localized manner as well. In this process, the optic disc is pulled towards the deepest point of the elongated eyeball, which might result in a change in optic disc configuration. Thus, we hypothesized that analyzing the variation of posterior pole contour can play a major role in understanding optic disc configuration in myopic subjects. By analyzing consecutive images of swept source OCT coronal sections at the posterior pole, the deepest interface between Bruch's membrane and the choroid could be identified as the deepest point of the eyeball (DPE). The location and the properties of the DPE differed significantly between the 125 eyes of non-glaucomatous myopic group and the 40 eyes of non-glaucomatous emmetropic group classified based on 24 mm axial length. The results suggested that the larger disc to DPE angle and the larger disc to DPE depth strongly predicts the optic disc torsion degree and the optic disc tilt. Our findings suggest that identifying the posterior pole profile plays a major role in understanding the optic disc alterations found in myopic subjects.
Coman, Laurenţiu; Costescu, Monica; Alecu, Mihail; Coman, Oana Andreia
2014-01-01
The purpose of this study was to evaluate the relationship between central corneal thickness (CCT) and optic disc morphology in normal tension glaucoma (NTG). Patients with NTG underwent eye examination, optic disc imaging with Heildelberg Retina Tomograph II (HRT II) and ultrasound corneal pachymetry. The morphological parameters of the optic discs were used to classify the eyes into four groups: generalized enlargement (GE) type, myopic glaucomatous (MY) type, focal ischemic (FI) type and senile sclerotic (SS) type. A correlation between CCT and optic disc morphology obtained by HRT II was calculated. Multiple comparison and post hoc tests were performed in order to determine the significance of the differences between the four groups. The strongest correlation was between CCT and the parameters of optic disc imaging obtained at HRT II in the GE type of optic disc.
PATHOGENESIS OF OPTIC DISC EDEMA IN RAISED INTRACRANIAL PRESSURE
Hayreh, Sohan Singh
2015-01-01
Optic disc edema in raised intracranial pressure was first described in 1853. Ever since, there has been a plethora of controversial hypotheses to explain its pathogenesis. I have explored the subject comprehensively by doing basic, experimental and clinical studies. My objective was to investigate the fundamentals of the subject, to test the validity of the previous theories, and finally, based on all these studies, to find a logical explanation for the pathogenesis. My studies included the following issues pertinent to the pathogenesis of optic disc edema in raised intracranial pressure: the anatomy and blood supply of the optic nerve, the roles of the sheath of the optic nerve, of the centripetal flow of fluids along the optic nerve, of compression of the central retinal vein, and of acute intracranial hypertension and its associated effects. I found that, contrary to some previous claims, an acute rise of intracranial pressure was not quickly followed by production of optic disc edema. Then, in rhesus monkeys, I produced experimentally chronic intracranial hypertension by slowly increasing in size space-occupying lesions, in different parts of the brain. Those produced raised cerebrospinal fluid pressure (CSFP) and optic disc edema, identical to those seen in patients with elevated CSFP. Having achieved that, I investigated various aspects of optic disc edema by ophthalmoscopy, stereoscopic color fundus photography and fluorescein fundus angiography, and light microscopic, electron microscopic, horseradish peroxidase and axoplasmic transport studies, and evaluated the effect of opening the sheath of the optic nerve on the optic disc edema. This latter study showed that opening the sheath resulted in resolution of optic disc edema on the side of the sheath fenestration, in spite of high intracranial CSFP, proving that a rise of CSFP in the sheath was the essential pre-requisite for the development of optic disc edema. I also investigated optic disc edema with raised CSFP in patients, by evaluating optic disc and fundus changes by stereoscopic fundus photography and fluorescein fundus angiography. Based on the combined information from all the studies discussed above, it is clear that the pathogenesis of optic disc edema in raised intracranial pressure is a mechanical phenomenon. It is primarily due to a rise of CSFP in the optic nerve sheath, which produces axoplasmic flow stasis in the optic nerve fibers in the surface nerve fiber layer and prelaminar region of the optic nerve head. Axoplasmic flow stasis then results in swelling of the nerve fibers, and consequently of the optic disc. Swelling of the nerve fibers and of the optic disc secondarily compresses the fine, low-pressure venules in that region, resulting in venous stasis and fluid leakage; that leads to the accumulation of extracellular fluid. Contrary to the previous theories, the various vascular changes seen in optic disc edema are secondary and not primary. Thus, optic disc edema in raised CSFP is due to a combination of swollen nerve fibers and the accumulation of extracellular fluid. My studies also provided information about the pathogeneses of visual disturbances in raised intracranial pressure. PMID:26453995
Pathogenesis of optic disc edema in raised intracranial pressure.
Hayreh, Sohan Singh
2016-01-01
Optic disc edema in raised intracranial pressure was first described in 1853. Ever since, there has been a plethora of controversial hypotheses to explain its pathogenesis. I have explored the subject comprehensively by doing basic, experimental and clinical studies. My objective was to investigate the fundamentals of the subject, to test the validity of the previous theories, and finally, based on all these studies, to find a logical explanation for the pathogenesis. My studies included the following issues pertinent to the pathogenesis of optic disc edema in raised intracranial pressure: the anatomy and blood supply of the optic nerve, the roles of the sheath of the optic nerve, of the centripetal flow of fluids along the optic nerve, of compression of the central retinal vein, and of acute intracranial hypertension and its associated effects. I found that, contrary to some previous claims, an acute rise of intracranial pressure was not quickly followed by production of optic disc edema. Then, in rhesus monkeys, I produced experimentally chronic intracranial hypertension by slowly increasing in size space-occupying lesions, in different parts of the brain. Those produced raised cerebrospinal fluid pressure (CSFP) and optic disc edema, identical to those seen in patients with elevated CSFP. Having achieved that, I investigated various aspects of optic disc edema by ophthalmoscopy, stereoscopic color fundus photography and fluorescein fundus angiography, and light microscopic, electron microscopic, horseradish peroxidase and axoplasmic transport studies, and evaluated the effect of opening the sheath of the optic nerve on the optic disc edema. This latter study showed that opening the sheath resulted in resolution of optic disc edema on the side of the sheath fenestration, in spite of high intracranial CSFP, proving that a rise of CSFP in the sheath was the essential pre-requisite for the development of optic disc edema. I also investigated optic disc edema with raised CSFP in patients, by evaluating optic disc and fundus changes by stereoscopic fundus photography and fluorescein fundus angiography. Based on the combined information from all the studies discussed above, it is clear that the pathogenesis of optic disc edema in raised intracranial pressure is a mechanical phenomenon. It is primarily due to a rise of CSFP in the optic nerve sheath, which produces axoplasmic flow stasis in the optic nerve fibers in the surface nerve fiber layer and prelaminar region of the optic nerve head. Axoplasmic flow stasis then results in swelling of the nerve fibers, and consequently of the optic disc. Swelling of the nerve fibers and of the optic disc secondarily compresses the fine, low-pressure venules in that region, resulting in venous stasis and fluid leakage; that leads to the accumulation of extracellular fluid. Contrary to the previous theories, the various vascular changes seen in optic disc edema are secondary and not primary. Thus, optic disc edema in raised CSFP is due to a combination of swollen nerve fibers and the accumulation of extracellular fluid. My studies also provided information about the pathogeneses of visual disturbances in raised intracranial pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.
[Clinical evaluation of the optic disc in glaucoma].
Greslechner, R; Spiegel, D
2016-10-01
Glaucoma is defined as a progressive neuropathy of the optic nerve, characterized by specific changes of the optic disc, parapapillary region, and retinal nerve fiber layer. Characteristic glaucomatous changes of the optic disc, parapapillary region, and retinal nerve fiber layer are discussed and their ophthalmoscopic examination is described. A literature search in the PubMed database was conducted. A systematic step-by-step approach to a qualitative and quantitative ophthalmoscopic evaluation of the optic disc regarding glaucomatous damage is presented. A systematic, clinical, qualitative, and quantitative assessment of the optic disc can be performed with little effort and forms the basis for diagnosis and treatment of glaucoma.
Archival-grade optical disc design and international standards
NASA Astrophysics Data System (ADS)
Fujii, Toru; Kojyo, Shinichi; Endo, Akihisa; Kodaira, Takuo; Mori, Fumi; Shimizu, Atsuo
2015-09-01
Optical discs currently on the market exhibit large variations in life span among discs, making them unsuitable for certain business applications. To assess and potentially mitigate this problem, we performed accelerated degradation testing under standard ISO conditions, determined the probable disc failure mechanisms, and identified the essential criteria necessary for a stable disc composition. With these criteria as necessary conditions, we analyzed the physical and chemical changes that occur in the disc components, on the basis of which we determined technological measures to reduce these degradation processes. By applying these measures to disc fabrication, we were able to develop highly stable optical discs.
Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.
Richter, Grace M; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Chopra, Vikas; Greenfield, David S; Varma, Rohit; Schuman, Joel S; Huang, David
2016-08-01
To report diagnostic accuracy of optical coherence tomography (OCT) disc variables using both time-domain (TD) and Fourier-domain (FD) OCT, and to improve the use of OCT disc variable measurements for glaucoma diagnosis through regression analyses that adjust for optic disc size and axial length-based magnification error. Observational, cross-sectional. In total, 180 normal eyes of 112 participants and 180 eyes of 138 participants with perimetric glaucoma from the Advanced Imaging for Glaucoma Study. Diagnostic variables evaluated from TD-OCT and FD-OCT were: disc area, rim area, rim volume, optic nerve head volume, vertical cup-to-disc ratio (CDR), and horizontal CDR. These were compared with overall retinal nerve fiber layer thickness and ganglion cell complex. Regression analyses were performed that corrected for optic disc size and axial length. Area-under-receiver-operating curves (AUROC) were used to assess diagnostic accuracy before and after the adjustments. An index based on multiple logistic regression that combined optic disc variables with axial length was also explored with the aim of improving diagnostic accuracy of disc variables. Comparison of diagnostic accuracy of disc variables, as measured by AUROC. The unadjusted disc variables with the highest diagnostic accuracies were: rim volume for TD-OCT (AUROC=0.864) and vertical CDR (AUROC=0.874) for FD-OCT. Magnification correction significantly worsened diagnostic accuracy for rim variables, and while optic disc size adjustments partially restored diagnostic accuracy, the adjusted AUROCs were still lower. Axial length adjustments to disc variables in the form of multiple logistic regression indices led to a slight but insignificant improvement in diagnostic accuracy. Our various regression approaches were not able to significantly improve disc-based OCT glaucoma diagnosis. However, disc rim area and vertical CDR had very high diagnostic accuracy, and these disc variables can serve to complement additional OCT measurements for diagnosis of glaucoma.
Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
Jia, Yali; Wei, Eric; Wang, Xiaogang; Zhang, Xinbo; Morrison, John C.; Parikh, Mansi; Lombardi, Lori H.; Gattey, Devin M.; Armour, Rebecca L.; Edmunds, Beth; Kraus, Martin F.; Fujimoto, James G.; Huang, David
2014-01-01
Purpose To compare optic disc perfusion between normal and glaucoma subjects using optical coherence tomography (OCT) angiography and detect optic disc perfusion changes in glaucoma. Design Observational, cross-sectional study. Participants Twenty-four normal subjects and 11 glaucoma patients were included. Methods One eye of each subject was scanned by a high-speed 1050 nm wavelength swept-source OCT instrument. The split-spectrum amplitude-decorrelation angiography algorithm (SSADA) was used to compute three-dimensional optic disc angiography. A disc flow index was computed from four registered scans. Confocal scanning laser ophthalmoscopy (cSLO) was used to measure disc rim area, and stereo photography was used to evaluate cup/disc ratios. Wide field OCT scans over the discs were used to measure retinal nerve fiber layer (NFL) thickness. Main Outcome Measurements Variability was assessed by coefficient of variation (CV). Diagnostic accuracy was assessed by sensitivity and specificity. Comparisons between glaucoma and normal groups were analyzed by Wilcoxon rank-sum test. Correlations between disc flow index, structural assessments, and visual field (VF) parameters were assessed by linear regression. Results In normal discs, a dense microvascular network was visible on OCT angiography. This network was visibly attenuated in glaucoma subjects. The intra-visit repeatability, inter-visit reproducibility, and normal population variability of the optic disc flow index were 1.2%, 4.2%, and 5.0% CV respectively. The disc flow index was reduced by 25% in the glaucoma group (p = 0.003). Sensitivity and specificity were both 100% using an optimized cutoff. The flow index was highly correlated with VF pattern standard deviation (R2 = 0.752, p = 0.001). These correlations were significant even after accounting for age, cup/disc area ratio, NFL, and rim area. Conclusions OCT angiography, generated by the new SSADA algorithm, repeatably measures optic disc perfusion. OCT angiography could be useful in the evaluation of glaucoma and glaucoma progression. PMID:24629312
Optic disc dysplasia in poland syndrome.
Maxfield, Steven D; Strominger, Mitchell B
2014-06-01
To report optic disc dysplasia in a case of Poland syndrome. Non-interventional case report. A 2-year-old boy with Poland syndrome was referred for ophthalmic evaluation after abnormal optic discs were found on exam. Physical exam at birth revealed right-sided aplasia of the pectoralis major muscle, symbrachydactyly, hypoplastic scapula, and an abnormal third rib. On dilated examination the optic nerve heads were dysplastic. The findings included multiple cilioretinal vessels, situs inversus, inferotemporal excavation, and surrounding pigmentary disturbances. Only one case of optic disc anomaly has been reported in Poland syndrome and was described as morning glory syndrome. The optic discs in our patient do not fit well with other optic disc excavation syndromes but are most reminiscent of those in papillorenal syndrome. As both Poland syndrome and papillorenal syndrome share vascular dysfunction as a possible etiology, this case adds to the literature of vascular dysgenesis in Poland syndrome.
Quantitating Human Optic Disc Topography
NASA Astrophysics Data System (ADS)
Graebel, William P.; Cohan, Bruce E.; Pearch, Andrew C.
1980-07-01
A method is presented for quantitatively expressing the topography of the human optic disc, applicable in a clinical setting to the diagnosis and management of glaucoma. Pho-tographs of the disc illuminated by a pattern of fine, high contrast parallel lines are digitized. From the measured deviation of the lines as they traverse the disc surface, disc topography is calculated, using the principles of optical sectioning. The quantitators applied to express this topography have the the following advantages : sensitivity to disc shape; objectivity; going beyond the limits of cup-disc ratio estimates and volume calculations; perfect generality in a mathematical sense; an inherent scheme for determining a non-subjective reference frame to compare different discs or the same disc over time.
The disappearance and reformation of the accretion disc during a low state of FO Aquarii
NASA Astrophysics Data System (ADS)
Hameury, J.-M.; Lasota, J.-P.
2017-09-01
Context. FO Aquarii, an asynchronous magnetic cataclysmic variable (intermediate polar) went into a low state in 2016, from which it slowly and steadily recovered without showing dwarf nova outbursts. This requires explanation since in a low state, the mass-transfer rate is in principle too low for the disc to be fully ionised and the disc should be subject to the standard thermal and viscous instability observed in dwarf novae. Aims: We investigate the conditions under which an accretion disc in an intermediate polar could exhibit a luminosity drop of two magnitudes in the optical band without showing outbursts. Methods: We use our numerical code for the time evolution of accretion discs, including other light sources from the system (primary, secondary, hot spot). Results: We show that although it is marginally possible for the accretion disc in the low state to stay on the hot stable branch, the required mass-transfer rate in the normal state would then have to be extremely high, of the order of 1019 g s-1 or even larger. This would make the system so intrinsically bright that its distance should be much larger than allowed by all estimates. We show that observations of FO Aqr are well accounted for by the same mechanism that we have suggested as explaining the absence of outbursts during low states of VY Scl stars: during the decay, the magnetospheric radius exceeds the circularisation radius, so that the disc disappears before it enters the instability strip for dwarf nova outbursts. Conclusions: Our results are unaffected, and even reinforced, if accretion proceeds both via the accretion disc and directly via the stream during some intermediate stages; the detailed process through which the disc disappears still requires investigation.
37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.
Code of Federal Regulations, 2013 CFR
2013-07-01
... permanent dark ink or its equivalent; and (v) Presented in a form having sufficient clarity and contrast... statement that the replacement compact disc contains no new matter. The compact disc and copy must be...
Petropoulos, Ioannis K; Pournaras, Jean-Antoine C; Stangos, Alexandros N; Pournaras, Constantin J
2009-01-01
To investigate the effect of systemic nitric oxide synthase (NOS) inhibition on optic disc oxygen partial pressure (PO(2)) in normoxia and hypercapnia. Intervascular optic disc PO(2) was measured in 12 anesthetized minipigs by using oxygen-sensitive microelectrodes placed <50 microm from the optic disc. PO(2) was measured continuously during 10 minutes under normoxia, hyperoxia (100% O(2)), carbogen breathing (95% O(2), 5% CO(2)), and hypercapnia (increased inhaled CO(2)). Measurements were repeated after intravenous injection of N(omega)-nitro-L-arginine methyl ester (L-NAME) 100 mg/kg. Intravenous L-arginine 100 mg/kg was subsequently given to three animals. Before L-NAME injection, an increase was observed in optic disc PO(2) during hypercapnia (DeltaPO(2) = 3.2 +/- 1.7 mm Hg; 18%; P = 0.001) and carbogen breathing (DeltaPO(2) = 12.8 +/- 5.1 mm Hg; 69%; P < 0.001). Optic disc PO(2) in normoxia remained stable for 30 minutes after L-NAME injection (4% decrease from baseline; P > 0.1), despite a 21% increase of mean arterial pressure. Optic disc PO(2) increase under hypercapnia was blunted after L-NAME injection (DeltaPO(2) = 0.6 +/- 1.1 mm Hg; 3%; P > 0.1), and this effect was reversible by L-arginine. Moreover, L-NAME reduced the response to carbogen by 29% (DeltaPO(2) = 9.1 +/- 4.4 mm Hg; 49%; P = 0.01 versus before L-NAME). The response to hyperoxia was not affected. Whereas systemic NOS inhibition did not affect optic disc PO(2) in normoxia, a blunting effect was noted on the CO(2)-induced optic disc PO(2) increase. Nitric oxide appears to mediate the hypercapnic optic disc PO(2) increase.
Dependence of optic disc parameters on disc area according to Heidelberg Retina Tomograph: Part II.
NASA Astrophysics Data System (ADS)
Machekhin, V.; Manaenkova, G.; Bondarenko, O.
2007-05-01
With the help of Heidelberg Retina Tomograph (HRT-II) optic disc parameters in 211 eyes of 115 healthy patients with refraction Em +/- 3,0 D and 96 eyes of 72 patients with myopia 3,5-14,0 D without any signs of glaucoma were studied. Analysis of optic disc parameters were carried out in 5 groups of patients according to disc area: less than 1,5 mm2, 1,5- 2,5 mm2, 2,5-3,0 mm2, 3,0-3,5 mm2 and more than 3,5 mm2. An accurate depending on disc area was revealed for all optic disc parameters in all sectors, which was manifested by increasing cup disc and rim disc (area and volume) and other parameters. We consider it is necessary to use the proper tables for right interpretation of received data for early diagnosis of glaucoma.
Automated volumetric evaluation of stereoscopic disc photography
Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A; Kagemann, Larry; Craig, Jamie E; Mackey, David A; Hewitt, Alex W; Schuman, Joel S
2010-01-01
PURPOSE: To develop a fully automated algorithm (AP) to perform a volumetric measure of the optic disc using conventional stereoscopic optic nerve head (ONH) photographs, and to compare algorithm-produced parameters with manual photogrammetry (MP), scanning laser ophthalmoscope (SLO) and optical coherence tomography (OCT) measurements. METHODS: One hundred twenty-two stereoscopic optic disc photographs (61 subjects) were analyzed. Disc area, rim area, cup area, cup/disc area ratio, vertical cup/disc ratio, rim volume and cup volume were automatically computed by the algorithm. Latent variable measurement error models were used to assess measurement reproducibility for the four techniques. RESULTS: AP had better reproducibility for disc area and cup volume and worse reproducibility for cup/disc area ratio and vertical cup/disc ratio, when the measurements were compared to the MP, SLO and OCT methods. CONCLUSION: AP provides a useful technique for an objective quantitative assessment of 3D ONH structures. PMID:20588996
Influence of height, weight, and body mass index on optic disc parameters.
Zheng, Yingfeng; Cheung, Carol Y L; Wong, Tien Y; Mitchell, Paul; Aung, Tin
2010-06-01
To examine the influence of body height, body weight, and body mass index (BMI) on optic disc parameters in a population-based study. The Singapore Malay Eye Study examined 3280 persons of Malay ethnicity, aged 40 to 80 years, of whom 2329 (71.0%) had reliable retinal scanning confocal laser tomography images for analyses. Intraocular pressure (IOP) was ascertained by Goldmann applanation tonometry. Body height and weight were measured with standardized protocols; BMI was calculated as weight (kilograms)/height squared (meters). Sociodemographic information was collected in an interviewer-administered questionnaire. In univariate analyses, body height, weight, and BMI were significantly associated with optic cup area, rim area, and cup-to-disc area ratio (all with P < 0.05) but none of the anthropometric parameters was significantly associated with optic disc area (all with P > 0.05). In multiple regression analyses after adjustment for age, sex, optic disc size, axial length, education, family income, and IOP, each SD increase in body height was associated with a 0.042-mm(2) decrease in optic rim area and a 0.020 increase in optic cup-to-disc area ratio; each SD decrease in body weight was associated with a 0.013-mm(2) decrease in optic rim area and a 0.010 increase in optic cup-to-disc ratio; and each SD decrease in BMI was associated with a 0.021-mm(2) decrease in optic rim area and a 0.010 increase in optic cup-to-disc ratio. Persons who are taller or have lower BMI have a smaller neuroretinal rim area and a larger optic cup-to-disc area ratio.
Fast localization of optic disc and fovea in retinal images for eye disease screening
NASA Astrophysics Data System (ADS)
Yu, H.; Barriga, S.; Agurto, C.; Echegaray, S.; Pattichis, M.; Zamora, G.; Bauman, W.; Soliz, P.
2011-03-01
Optic disc (OD) and fovea locations are two important anatomical landmarks in automated analysis of retinal disease in color fundus photographs. This paper presents a new, fast, fully automatic optic disc and fovea localization algorithm developed for diabetic retinopathy (DR) screening. The optic disc localization methodology comprises of two steps. First, the OD location is identified using template matching and directional matched filter. To reduce false positives due to bright areas of pathology, we exploit vessel characteristics inside the optic disc. The location of the fovea is estimated as the point of lowest matched filter response within a search area determined by the optic disc location. Second, optic disc segmentation is performed. Based on the detected optic disc location, a fast hybrid level-set algorithm which combines the region information and edge gradient to drive the curve evolution is used to segment the optic disc boundary. Extensive evaluation was performed on 1200 images (Messidor) composed of 540 images of healthy retinas, 431 images with DR but no risk of macular edema (ME), and 229 images with DR and risk of ME. The OD location methodology obtained 98.3% success rate, while fovea location achieved 95% success rate. The average mean absolute distance (MAD) between the OD segmentation algorithm and "gold standard" is 10.5% of estimated OD radius. Qualitatively, 97% of the images achieved Excellent to Fair performance for OD segmentation. The segmentation algorithm performs well even on blurred images.
Ensuring long-term reliability of the data storage on optical disc
NASA Astrophysics Data System (ADS)
Chen, Ken; Pan, Longfa; Xu, Bin; Liu, Wei
2008-12-01
"Quality requirements and handling regulation of archival optical disc for electronic records filing" is released by The State Archives Administration of the People's Republic of China (SAAC) on its network in March 2007. This document established a complete operative managing process for optical disc data storage in archives departments. The quality requirements of the optical disc used in archives departments are stipulated. Quality check of the recorded disc before filing is considered to be necessary and the threshold of the parameter of the qualified filing disc is set down. The handling regulations for the staffs in the archives departments are described. Recommended environment conditions of the disc preservation, recording, accessing and testing are presented. The block error rate of the disc is selected as main monitoring parameter of the lifetime of the filing disc and three classes pre-alarm lines are created for marking of different quality check intervals. The strategy of monitoring the variation of the error rate curve of the filing discs and moving the data to a new disc or a new media when the error rate of the disc reaches the third class pre-alarm line will effectively guarantee the data migration before permanent loss. Only when every step of the procedure is strictly implemented, it is believed that long-term reliability of the data storage on optical disc for archives departments can be effectively ensured.
Optic disc size and other parameters from optical coherence tomography in Vietnamese-Americans.
Peng, Pai-Huei; Fu, Sheena; Nguyen, Ngoc; Porco, Travis; Lin, Shan C
2011-08-01
To investigate the optic disc parameters by optical coherence tomography (OCT) in Vietnamese with various types of glaucoma. Medical charts of Vietnamese and White patients within a single practice were reviewed. Disc and rim areas by OCT were compared among nonglaucoma controls, different types of glaucoma, and glaucoma suspect. The association of these parameters with demographic and ocular features was evaluated. Data from 1416 Vietnamese and 57 White patients were included. A larger mean disc area was observed in eyes with primary angle-closure glaucoma than in eyes with primary angle-closure and primary angle-closure suspect (both P<0.001). There was no association between disc size with central corneal thickness (P=0.051) and sex (P=0.155). Vietnamese patients with glaucoma and glaucoma suspicion had larger discs than diagnosis-matched Whites (P=0.043 and 0.021, respectively). Vietnamese patients with glaucoma seem to have larger optic discs than White patients. Central corneal thickness had no association with disc area in this study population.
37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.
Code of Federal Regulations, 2014 CFR
2014-07-01
... by a typewriter or machine printer in permanent dark ink or its equivalent; and (v) Presented in a... accompanied by a statement that the replacement compact disc contains no new matter. The compact disc and copy...
Utility of Digital Stereo Images for Optic Disc Evaluation
Ying, Gui-shuang; Pearson, Denise J.; Bansal, Mayank; Puri, Manika; Miller, Eydie; Alexander, Judith; Piltz-Seymour, Jody; Nyberg, William; Maguire, Maureen G.; Eledath, Jayan; Sawhney, Harpreet
2010-01-01
Purpose. To assess the suitability of digital stereo images for optic disc evaluations in glaucoma. Methods. Stereo color optic disc images in both digital and 35-mm slide film formats were acquired contemporaneously from 29 subjects with various cup-to-disc ratios (range, 0.26–0.76; median, 0.475). Using a grading scale designed to assess image quality, the ease of visualizing optic disc features important for glaucoma diagnosis, and the comparative diameters of the optic disc cup, experienced observers separately compared the primary digital stereo images to each subject's 35-mm slides, to scanned images of the same 35-mm slides, and to grayscale conversions of the digital images. Statistical analysis accounted for multiple gradings and comparisons and also assessed image formats under monoscopic viewing. Results. Overall, the quality of primary digital color images was judged superior to that of 35-mm slides (P < 0.001), including improved stereo (P < 0.001), but the primary digital color images were mostly equivalent to the scanned digitized images of the same slides. Color seemingly added little to grayscale optic disc images, except that peripapillary atrophy was best seen in color (P < 0.0001); both the nerve fiber layer (P < 0.0001) and the paths of blood vessels on the optic disc (P < 0.0001) were best seen in grayscale. The preference for digital over film images was maintained under monoscopic viewing conditions. Conclusions. Digital stereo optic disc images are useful for evaluating the optic disc in glaucoma and allow the application of advanced image processing applications. Grayscale images, by providing luminance distinct from color, may be informative for assessing certain features. PMID:20505199
Normal-tension glaucoma (Low-tension glaucoma)
Anderson, Douglas R
2011-01-01
Glaucoma is now considered an abnormal physiology in the optic nerve head that interacts with the level of intraocular pressure (IOP), with the degree and rate of damage depending on the IOP and presumably the degree of abnormal physiology. Diagnosis of normal-tension glaucoma (NTG), defined as glaucoma without a clearly abnormal IOP, depends on recognizing symptoms and signs associated with optic nerve vulnerability, in addition to absence of other explanations for disc abnormality and visual field loss. Among the findings are a halo or crescent of absence of retinal pigment epithelium around the disc, bilateral pre-chiasmal visual field defects, splinter hemorrhages at the disc margin, vascular dysregulation (low blood pressure, cold hands and feet, migraine headache with aura, and the like), or a family history of glaucoma. Possibly relevant, is a history of hemodynamic crisis, arterial obstructive disease, or sleep apnea. Neurological evaluation with imaging is needed only for atypical cases or ones that progress unexpectedly. Management follows the same principle of other chronic glaucomas, to lower the IOP by a substantial amount, enough to prevent disabling visual loss. However, many NTG cases are non-progressive. Therefore, it may often be wisein mild cases to determine whether the case is progressive and the rate of progression before deciding on how aggressivene to be with therapy. Efforts at neuroprotection and improvement in blood flow have not yet been shown effective. PMID:21150042
Subramanian, Prem S; Gordon, Lynn K; Bonelli, Laura; Arnold, Anthony C
2017-05-01
The time of onset of optic disc swelling in non-arteritic anterior ischaemic optic neuropathy (NAION) is not known, and it is commonly assumed to arise simultaneously with vision loss. Our goal is to report the presence and persistence of optic disc swelling without initial vision loss and its subsequent evolution to typical, symptomatic NAION. Clinical case series of patients with optic disc swelling and normal visual acuity and visual fields at initial presentation who progressed to have vision loss typical of NAION. All subjects underwent automated perimetry, disc photography and optic coherence tomography and/or fluorescein angiography to evaluate optic nerve function and perfusion. Four patients were found to have sectoral or diffuse optic disc swelling without visual acuity or visual field loss; the fellow eye of all four had either current or prior NAION or a 'disc at risk' configuration. Over several weeks of clinical surveillance, each patient experienced sudden onset of visual field and/or visual acuity loss typical for NAION. Current treatment options for NAION once vision loss occurs are limited and may not alter the natural history of the disorder. Subjects with NAION may have disc swelling for 2-10 weeks prior to the occurrence of visual loss, and with the development of new therapeutic agents, treatment at the time of observed disc swelling could prevent vision loss from NAION. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Prediction of functional loss in glaucoma from progressive optic disc damage.
Medeiros, Felipe A; Alencar, Luciana M; Zangwill, Linda M; Bowd, Christopher; Sample, Pamela A; Weinreb, Robert N
2009-10-01
To evaluate the ability of progressive optic disc damage detected by assessment of longitudinal stereophotographs to predict future development of functional loss in those with suspected glaucoma. The study included 639 eyes of 407 patients with suspected glaucoma followed up for an average of 8.0 years with annual standard automated perimetry visual field and optic disc stereophotographs. All patients had normal and reliable standard automated perimetry results at baseline. Conversion to glaucoma was defined as development of 3 consecutive abnormal visual fields during follow-up. Presence of progressive optic disc damage was evaluated by grading longitudinally acquired simultaneous stereophotographs. Other predictive factors included age, intraocular pressure, central corneal thickness, pattern standard deviation, and baseline stereophotograph grading. Hazard ratios for predicting visual field loss were obtained by extended Cox models, with optic disc progression as a time-dependent covariate. Predictive accuracy was evaluated using a modified R(2) index. Progressive optic disc damage had a hazard ratio of 25.8 (95% confidence interval, 16.0-41.7) and was the most important risk factor for development of visual field loss with an R(2) of 79%. The R(2)s for other predictive factors ranged from 6% to 26%. Presence of progressive optic disc damage on stereophotographs was a highly predictive factor for future development of functional loss in glaucoma. These findings suggest the importance of careful monitoring of the optic disc appearance and a potential role for longitudinal assessment of the optic disc as an end point in clinical trials and as a reference for evaluation of diagnostic tests in glaucoma.
Anterior ischemic optic neuropathy in a patient with Churg-Strauss syndrome.
Lee, Ji Eun; Lee, Seung Uk; Kim, Soo Young; Jang, Tae Won; Lee, Sang Joon
2012-12-01
We describe a patient with Churg-Strauss syndrome who developed unilateral anterior ischemic optic neuropathy. A 54-year-old man with a history of bronchial asthma, allergic rhinitis, and sinusitis presented with sudden decreased visual acuity in his right eye that had begun 2 weeks previously. The visual acuity of his right eye was 20 / 50. Ophthalmoscopic examination revealed a diffusely swollen right optic disc and splinter hemorrhages at its margin. Goldmann perimetry showed central scotomas in the right eye and fluorescein angiography showed remarkable hyperfluorescence of the right optic nerve head. Marked peripheral eosinphilia, extravascular eosinophils in a bronchial biopsy specimen, and an increased sedimentation rate supported the diagnosis of Churg-Strauss syndrome. Therapy with methylprednisolone corrected the laboratory abnormalities, improved clinical features, and preserved vision, except for the right central visual field defect. Early recognition of this systemic disease by ophthalmologists may help in preventing severe ocular complications.
Anterior Ischemic Optic Neuropathy in a Patient with Churg-Strauss Syndrome
Lee, Ji Eun; Lee, Seung Uk; Kim, Soo Young; Jang, Tae Won
2012-01-01
We describe a patient with Churg-Strauss syndrome who developed unilateral anterior ischemic optic neuropathy. A 54-year-old man with a history of bronchial asthma, allergic rhinitis, and sinusitis presented with sudden decreased visual acuity in his right eye that had begun 2 weeks previously. The visual acuity of his right eye was 20 / 50. Ophthalmoscopic examination revealed a diffusely swollen right optic disc and splinter hemorrhages at its margin. Goldmann perimetry showed central scotomas in the right eye and fluorescein angiography showed remarkable hyperfluorescence of the right optic nerve head. Marked peripheral eosinphilia, extravascular eosinophils in a bronchial biopsy specimen, and an increased sedimentation rate supported the diagnosis of Churg-Strauss syndrome. Therapy with methylprednisolone corrected the laboratory abnormalities, improved clinical features, and preserved vision, except for the right central visual field defect. Early recognition of this systemic disease by ophthalmologists may help in preventing severe ocular complications. PMID:23204805
Savini, G; Zanini, M; Carelli, V; Sadun, A A; Ross-Cisneros, F N; Barboni, P
2005-04-01
To investigate the correlation between retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) size in normal white subjects by means of optical coherence tomography (OCT). 54 eyes of 54 healthy subjects aged between 15 and 54 underwent peripapillary RNFL thickness measurement by a series of three circular scans with a 3.4 mm diameter (Stratus OCT, RNFL Thickness 3.4 acquisition protocol). ONH analysis was performed by means of six radial scans centred on the optic disc (Stratus OCT, Fast Optic Disc acquisition protocol). The mean RNFL values were correlated with the data obtained by ONH analysis. The superior, nasal, and inferior quadrant RNFL thickness showed a significant correlation with the optic disc area (R = 0.3822, p = 0.0043), (R = 0.3024, p = 0.026), (R = 0.4048, p = 0.0024) and the horizontal disc diameter (R = 0.2971, p = 0.0291), (R = 0.2752, p = 0.044), (R = 0.3970, p = 0.003). The superior and inferior quadrant RNFL thickness was also positively correlated with the vertical disc diameter (R = 0.3774, p = 0.0049), (R = 0.2793, p = 0.0408). A significant correlation was observed between the 360 degrees average RNFL thickness and the optic disc area and the vertical and horizontal disc diameters of the ONH (R = 0.4985, p = 0.0001), (R = 0.4454, p = 0.0007), (R = 0.4301, p = 0.0012). RNFL thickness measurements obtained by Stratus OCT increased significantly with an increase in optic disc size. It is not clear if eyes with large ONHs show a thicker RNFL as a result of an increased amount of nerve fibres or to the shorter distance between the circular scan and the optic disc edge.
Optical excess of dim isolated neutron stars
NASA Astrophysics Data System (ADS)
Ertan, Ü.; Çalışkan, Ş.; Alpar, M. A.
2017-09-01
The optical excess in the spectra of dim isolated neutron stars (XDINs) is a significant fraction of their rotational energy loss rate. This is strikingly different from the situation in isolated radio pulsars. We investigate this problem in the framework of the fallback disc model. The optical spectra can be powered by magnetic stresses on the innermost disc matter, as the energy dissipated is emitted as blackbody radiation mainly from the inner rim of the disc. In the fallback disc model, XDINs are the sources evolving in the propeller phase with similar torque mechanisms. In this model, the ratio of the total magnetic work that heats up the inner disc matter is expected to be similar for different XDINs. Optical luminosities that are calculated consistently with the optical spectra and the theoretical constraints on the inner disc radii give very similar ratios of the optical luminosity to the rotational energy loss rate for all these sources. These ratios indicate that a significant fraction of the magnetic torque heats up the disc matter while the remaining fraction expels disc matter from the system. For XDINs, the contribution of heating by X-ray irradiation to the optical luminosity is negligible in comparison with the magnetic heating. The correlation we expect between the optical luminosities and the rotational energy loss rates of XDINs can be a property of the systems with low X-ray luminosities, in particular those in the propeller phase.
Comparison of Laser Scanning Diagnostic Devices for Early Glaucoma Detection.
Schulze, Andreas; Lamparter, Julia; Pfeiffer, Norbert; Berisha, Fatmire; Schmidtmann, Irene; Hoffmann, Esther M
2015-08-01
To compare the diagnostic accuracy and to evaluate the correlation of optic nerve head and retinal nerve fiber layer thickness values between Fourier-Domain optical coherence tomography (FD-OCT), confocal scanning laser ophthalmoscopy (CSLO), and scanning laser polarimetry (SLP) for early glaucoma detection. Ninety-three patients with early open-angle glaucoma, 58 patients with ocular hypertension, and 60 healthy control subjects were included in this observational, cross-sectional study. All study participants underwent FD-OCT (RTVue-100), CSLO (HRT3), and SLP (GDx VCC) imaging of the optic nerve head and the retinal nerve fiber layer. Area under the receiver operating characteristic curves (AUROC) and Bland-Altman analysis were performed. The parameters with the highest diagnostic accuracy were found for FD-OCT cup-to-disc ratio (AUROC=0.841), for SLP NFI (AUROC=0.835), and for CSLO cup-to-disc ratio (AUROC=0.789). Diagnostic accuracy of the best CSLO and SLP parameter was similar (P=0.259). There was a small statistically significant difference between the best CSLO and FD-OCT parameters for differentiating between glaucoma and healthy eyes (P=0.047). FD-OCT and SLP have a similarly good diagnostic ability to distinguish between early glaucoma and healthy subjects. The diagnostic accuracy of CSLO was comparable with SLP and marginally lower compared with FD-OCT.
Birth weight and optic nerve head parameters.
Samarawickrama, Chameen; Huynh, Son C; Liew, Gerald; Burlutsky, George; Mitchell, Paul
2009-06-01
To assess the relationship of birth weight, birth length, and head circumference as proxy markers of intrauterine growth, cup/disc ratio, and other optic disc parameters measured using optical coherence tomography (OCT). Population-based cross sectional analysis. The Sydney Childhood Eye Study examined 2353 primarily 12-year-old children from 21 randomly selected secondary schools during 2003 to 2005. Of 2353 children examined, 2134 (90.7%) had OCT scans (Zeiss Stratus OCT, Carl Zeiss Meditec, Dublin, CA) and are included in this study. The "fast" optic disc scan protocol was used. Birth weight, birth length, and head circumference were ascertained from health records. Height and weight were measured using standardized protocols, body mass index (BMI) was defined as weight (kilograms)/ height squared (meters), and sociodemographic information was collected in a questionnaire completed by parents. Low birth weight was defined as birth weight
Optic disc coloboma in two nigerian siblings: Case report and review of literature.
Babalola, Y O; Olawoye, O O; Idam, P O
2017-11-01
We report two cases of bilateral asymmetric optic disc coloboma (ODC) in siblings. The index patient is a 9-year-old Nigerian girl with severe cognitive deficit who presented with a poor vision of 3 years' duration. She had a history of childhood febrile convulsions and delayed developmental milestones. Her visual acuity could not be assessed because she had a cognitive deficit and expressive aphasia. Ocular examination revealed a very large excavated right optic disc with only a strip of remnant neuro-retinal rim superiorly, and a smaller left optic disc with inferior disc excavation, superior wedge of the pink neuro-retinal rim as well as a temporal optic disc pit. No systemic features of syndromes associated with ODCs and intellectual disability were present in both patients. The younger sibling an 8-year-old girl later presented to the eye clinic with a 5-month history of poor vision in the left eye. Ocular examination revealed visual acuity of 6/6 in the right eye and counting fingers in the left eye. Dilated binocular indirect ophthalmoscopy revealed a right large excavated colobomatous disc and a left small disc with infero-temporal disc coloboma.
Topographic optic disc analysis by Heidelberg retinal tomography in ocular Behçet's disease
Berker, Nilufer; Elgin, Ufuk; Ozdal, Pinar; Batman, Aygen; Soykan, Emel; Ozkan, Seyhan S
2007-01-01
Aim To compare the topographic characteristics of the optic discs in patients with severe and mild ocular Behçet's disease by using Heidelberg retinal tomographaphy (HRT). Methods This prospective study included 47 eyes of 47 patients with ocular BD who were being followed‐up at the Uveitis Clinic of the Ankara Ulucanlar Eye Research Hospital, Ankara, Turkey. The patients were divided into two groups. Group 1 consisted of 21 eyes with mild uveitis, and group 2 consisted of 26 eyes with severe uveitis. All patients underwent topographic optic disc analysis by HRT II, and the quantitative optic disc parameters of both groups were compared by non‐parametric Mann‐Whitney U test. Results The mean cup volume, rim volume, cup area, disc area and cup depth in group 1 were found to be statistically significantly greater than those in group 2 (p<0.0001, p = 0.03, p = 0.021, p = 0.01 and p = 0.017, respectively), while the difference between the mean cup‐to‐disc ratios in group 1 and group 2 were found to be statistically insignificant (p = 0.148). Conclusion A relationship was found between the severity of ocular BD and optic disc topography determined by HRT. In eyes with smaller optic discs, uveitis was observed to have a more severe course with more frequent relapses than those with larger discs. PMID:17475703
Topographic optic disc analysis by Heidelberg retinal tomography in ocular Behcet's disease.
Berker, Nilufer; Elgin, Ufuk; Ozdal, Pinar; Batman, Aygen; Soykan, Emel; Ozkan, Seyhan S
2007-09-01
To compare the topographic characteristics of the optic discs in patients with severe and mild ocular Behçet's disease by using Heidelberg retinal tomographaphy (HRT). This prospective study included 47 eyes of 47 patients with ocular BD who were being followed-up at the Uveitis Clinic of the Ankara Ulucanlar Eye Research Hospital, Ankara, Turkey. The patients were divided into two groups. Group 1 consisted of 21 eyes with mild uveitis, and group 2 consisted of 26 eyes with severe uveitis. All patients underwent topographic optic disc analysis by HRT II, and the quantitative optic disc parameters of both groups were compared by non-parametric Mann-Whitney U test. The mean cup volume, rim volume, cup area, disc area and cup depth in group 1 were found to be statistically significantly greater than those in group 2 (p<0.0001, p = 0.03, p = 0.021, p = 0.01 and p = 0.017, respectively), while the difference between the mean cup-to-disc ratios in group 1 and group 2 were found to be statistically insignificant (p = 0.148). A relationship was found between the severity of ocular BD and optic disc topography determined by HRT. In eyes with smaller optic discs, uveitis was observed to have a more severe course with more frequent relapses than those with larger discs.
Elgin, Ufuk; Cankaya, Bülent; Simsek, Tulay; Batman, Aygen
2010-01-01
To compare the optic disc topography parameters of children with juvenile diabetes mellitus and normal children using the Heidelberg Retinal Tomograph (HRT III) (Heidelberg Engineering, Heidelberg, Germany). The topographic optic disc parameters (cup volume, cup area, rim volume, rim area, disc area, mean cup-to-disc ratio, and mean cup depth) of 28 non-glaucomatous eyes of 28 children with type 1 diabetes mellitus and 28 eyes of 28 age-matched healthy children were compared using the nonparametric Mann-Whitney U test. No statistically significant differences were found between cup volume (P = .782), cup area (P = .878), rim volume (P = .853), disc area (P = .452), mean cup-to-disc ratio (P = .852), and mean cup depth (P = .711) of eyes of cases with diabetes mellitus and normal subjects. This result suggests that non-glaucomatous eyes of children with type 1 diabetes mellitus and healthy subjects have similar topographic optic disc characteristics. Copyright 2010, SLACK Incorporated.
Seo, Sam; Lee, Chong Eun; Jeong, Jae Hoon; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook
2017-03-11
To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spherical equivalent (SE) values and optic disc area. All underwent Cirrus HD-OCT imaging. The influences of myopia and optic disc size on the GCIPL and RNFL thickness profiles were evaluated by multiple comparisons and linear regression analysis. Three-dimensional surface plots of GCIPL and RNFL thickness corresponding to different combinations of myopia and optic disc size were constructed. Each of the quadrant RNFL thicknesses and their overall average were significantly thinner in high myopia compared to low myopia, except for the temporal quadrant (all Ps ≤0.003). The average and all-sectors GCIPL were significantly thinner in high myopia than in moderate- and/or low-myopia (all Ps ≤0.002). The average OCT RNFL thickness was correlated significantly with SE (0.81 μm/diopter, P < 0.001), axial length (-1.44 μm/mm, P < 0.001), and optic disc area (5.35 μm/mm 2 , P < 0.001) by linear regression analysis. As for the OCT GCIPL parameters, average GCIPL thickness showed a significant correlation with SE (0.84 μm/diopter, P < 0.001) and axial length (-1.65 μm/mm, P < 0.001). There was no significant correlation of average GCIPL thickness with optic disc area. Three-dimensional curves showed that larger optic discs were associated with increased average RNFL thickness and that more-myopic eyes were associated with decreased average GCIPL and RNFL thickness. Myopia can significantly affect GCIPL and RNFL thickness profiles, and optic disc size has a significant influence on RNFL thickness. The current OCT maps employed in the evaluation of glaucoma should be analyzed in consideration of refractive status and optic disc size.
A novel method for retinal optic disc detection using bat meta-heuristic algorithm.
Abdullah, Ahmad S; Özok, Yasa Ekşioğlu; Rahebi, Javad
2018-05-09
Normally, the optic disc detection of retinal images is useful during the treatment of glaucoma and diabetic retinopathy. In this paper, the novel preprocessing of a retinal image with a bat algorithm (BA) optimization is proposed to detect the optic disc of the retinal image. As the optic disk is a bright area and the vessels that emerge from it are dark, these facts lead to the selected segments being regions with a great diversity of intensity, which does not usually happen in pathological regions. First, in the preprocessing stage, the image is fully converted into a gray image using a gray scale conversion, and then morphological operations are implemented in order to remove dark elements such as blood vessels, from the images. In the next stage, a bat algorithm (BA) is used to find the optimum threshold value for the optic disc location. In order to improve the accuracy and to obtain the best result for the segmented optic disc, the ellipse fitting approach was used in the last stage to enhance and smooth the segmented optic disc boundary region. The ellipse fitting is carried out using the least square distance approach. The efficiency of the proposed method was tested on six publicly available datasets, MESSIDOR, DRIVE, DIARETDB1, DIARETDB0, STARE, and DRIONS-DB. The optic disc segmentation average overlaps and accuracy was in the range of 78.5-88.2% and 96.6-99.91% in these six databases. The optic disk of the retinal images was segmented in less than 2.1 s per image. The use of the proposed method improved the optic disc segmentation results for healthy and pathological retinal images in a low computation time. Graphical abstract ᅟ.
Roberts, Kenneth F; Artes, Paul H; O'Leary, Neil; Reis, Alexandre S C; Sharpe, Glen P; Hutchison, Donna M; Chauhan, Balwantray C; Nicolela, Marcelo T
2012-08-01
To examine peripapillary choroidal thickness in healthy controls and in patients with glaucoma who have focal, diffuse, and sclerotic optic disc damage. Healthy controls (n=92) and patients with glaucoma who have focal (n=34), diffuse (n=35), and sclerotic (n=34) optic disc damage were imaged with spectral-domain optical coherence tomography (12° circular scan protocol centered on optic nerve head). Peripapillary choroidal thickness was measured as the distance between the automatically segmented retinal pigment epithelium/Bruch's membrane and the manually outlined interface between the posterior choroid and the anterior border of the sclera in eyes in which the anterior scleral border was visible over more than 85% of the scan circumference. The anterior scleral border was visible in 76 controls (83%) and 89 patients (86%). Peripapillary choroidal thickness in healthy controls decreased linearly with age (-11 μm/decade; P.001; r2=0.16), with a predicted value of 137 μm at age 70 years (95% prediction interval, 62-212 μm). While this value was similar in patients with focal and diffuse optic disc damage (126 and 130 μm, respectively; P=.22 compared with controls), it was approximately 30% lower in patients with sclerotic optic disc damage (96 μm; P.001 compared with controls). The peripapillary choroid of patients with glaucoma who have sclerotic optic disc damage was approximately 25% to 30% thinner compared with that in patients with focal and diffuse optic disc damage and with that in healthy controls. The role of the choroid in the pathophysiology of sclerotic glaucomatous optic disc damage needs further investigation.
Knight, O'Rese J; Girkin, Christopher A; Budenz, Donald L; Durbin, Mary K; Feuer, William J
2012-03-01
To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P ≤ .005) except rim area (P = .22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r(2) = 0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups.
Knight, O’Rese J.; Girkin, Christopher A.; Budenz, Donald L.; Durbin, Mary K.; Feuer, William J.
2017-01-01
Objective To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. Methods In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. Results The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P≤.005) except rim area (P=.22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r2=0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. Conclusions There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups. PMID:22411660
Hua, Zanmei; Fang, Qiuyun; Sha, Xiangyin; Yang, Ruiming; Hong, Zuopeng
2015-03-01
Glaucoma is an eye disease that can lead to irreversible optic nerve damage and cause blindness. Optical coherence tomography (OCT) allows an early diagnosis of glaucoma by the measurements of the retinal nerve fiber and optic disc parameters. A retrospective study was designed to analyze the effects of the measurement of the retinal nerve fiber layer (RNFL) thickness and the optic disc tomography by spectral-domain OCT on the early diagnosis of suspected glaucoma and primary open angle glaucoma (POAG). This was a clinical case-control study. The RNFL thickness around the optic disc and optic disk tomographic parameters of the control (n = 51, 98 eyes), suspected glaucoma (n = 81, 146 eyes), and POAG groups (n = 55, 106 eyes) were measured by OCT. The parameters included superior, inferior, nasal and temporal mean RNFL thickness, disc area (DA), cup area (CA), rim area (RA), disc volume (DV), cup volume (CV), rim volume (RV), cup/disc area ratio (CA/DA), rim/disc area ratio (RA/DA), cup/disc volume ratio (CV/DV) and rim/disc volume ratio (RV/DV). Superior, nasal, and mean RNFL parameters, DA, CA,RA, DV, CV, CA/DA, RA/DA, CV/DV and RV/DV significantly differed among three groups by single-factorial ANOVA. Inferior and temporal RNFL thickness significantly differed between the control and POAG groups. No significant difference was observed in RV among three groups. In the POAG group, the maximum area under the ROC curve (AROC) of mean RNFL thickness was 0.845. The maximum AROC of optic disk parameters was RA/DA (0.998), followed by CA/DA (0.997). The AROC of CA, RA, CV, and DV were all > 0.900. OCT may serve as a useful diagnostic modality in distinguishing suspected glaucoma from POAG.
Flores-Rodríguez, Patricia; Gili, Pablo; Martín-Ríos, María Dolores; Grifol-Clar, Eulalia
2013-03-01
To compare optic disc area measurement between optic nerve head drusen (ONHD) and control subjects using fundus photography, time-domain optical coherence tomography (TD-OCT) and spectral-domain optical coherence tomography (SD-OCT). We also made a comparison between each of the three techniques. We performed our study on 66 eyes (66 patients) with ONHD and 70 healthy control subjects (70 controls) with colour ocular fundus photography at 20º (Zeiss FF 450 IR plus), TD-OCT (Stratus OCT) with the Fast Optic Disc protocol and SD-OCT (Cirrus OCT) with the Optic Disc Cube 200 × 200 protocol for measurement of the optic disc area. The measurements were made by two observers and in each measurement a correction of the image magnification factor was performed. Measurement comparison using the Student's t-test/Mann-Whitney U test, the intraclass correlation coefficient, Pearson/Spearman rank correlation coefficient and the Bland-Altman plot was performed in the statistical analysis. Mean and standard deviation (SD) of the optic disc area in ONHD and in controls was 2.38 (0.54) mm(2) and 2.54 (0.42) mm(2), respectively with fundus photography; 2.01 (0.56) mm(2) and 1.66 (0.37) mm(2), respectively with TD-OCT, and 2.03 (0.49) mm(2) and 1.75 (0.38) mm(2), respectively with SD-OCT. In ONHD and controls, repeatability of optic disc area measurement was excellent with fundus photography and optical coherence tomography (TD-OCT and SD-OCT), but with a low degree of agreement between both techniques. Optic disc area measurement is smaller in ONHD compared to healthy subjects with fundus photography, unlike time-domain and spectral-domain optical coherence tomography in which the reverse is true. Both techniques offer good repeatability, but a low degree of correlation and agreement, which means that optic disc area measurement is not interchangeable or comparable between techniques. Ophthalmic & Physiological Optics © 2013 The College of Optometrists.
The Chemistry of Optical Discs.
ERIC Educational Resources Information Center
Birkett, David
2002-01-01
Explains the chemistry used in compact discs (CD), digital versatile discs (DVD), and magneto-optical (MO) discs focusing on the steps of initial creation of the mold, the molding of the polycarbonate, the deposition of the reflective layers, the lacquering of the CDs, and the bonding of DVDs. (Contains 15 references.) (YDS)
LkHα 262/263: the paradigm of multiplicity vs disk fraction in low-mass stellar systems.
NASA Astrophysics Data System (ADS)
Velasco, S.; Rebolo, R.; Oscoz, A.; Labadie, L.; Pérez-Garrido, A.
2017-03-01
The study of multiple systems and their link with the presence of discs around their components is key to understanding the evolution of low-mass pre-main sequence stars. Although there are indications that high-multiplicity systems are much more frequent among very young stars, until now, only a few of these young low-mass stellar systems have been confirmed. Here, we present high spatial resolution i band imaging of the system formed by LkHα 262 and LkHα 263, in the MBM12 cloud. It was obtained during the first commissioning period of the Adaptive Optics Lucky Imager (AOLI) at the 4.2 m William Herschel Telescope, using its Lucky Imaging mode. The multiple system LkHα 262/263 is composed of four low-mass very young M-type stars and some discs, including an edge-on disc around LkHα 263C. The AOLI data combined with previously available and newly obtained optical and infrared imaging show that the three components of LkHα 263 are co-moving, that there is orbital motion in the AB pair (0.41arcsec separation), and, remarkably, that LkHα 262-263 is a common proper motion system with a less than 1 mas/yr relative motion. According to BT-settl models the mass of each of the five components is close to 0.4 M and the age is in the range 1-2 Myr. We also give marginal evidence of a cooler companion to LkHα 262, at less than 0.15 arcsec, turning LkHα 262-263 into a five-component likely gravitationally bounded system. The presence of discs in some of the components offers an interesting opportunity to investigate the formation and evolution of discs in the early stages of multiple very low-mass systems.
Vertical cup-to-disc ratio measurement for diagnosis of glaucoma on fundus images
NASA Astrophysics Data System (ADS)
Hatanaka, Yuji; Noudo, Atsushi; Muramatsu, Chisako; Sawada, Akira; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi
2010-03-01
Glaucoma is a leading cause of permanent blindness. Retinal fundus image examination is useful for early detection of glaucoma. In order to evaluate the presence of glaucoma, the ophthalmologists determine the cup and disc areas and they diagnose glaucoma using a vertical cup-to-disc ratio. However, determination of the cup area is very difficult, thus we propose a method to measure the cup-to-disc ratio using a vertical profile on the optic disc. First, the blood vessels were erased from the image and then the edge of optic disc was then detected by use of a canny edge detection filter. Twenty profiles were then obtained around the center of the optic disc in the vertical direction on blue channel of the color image, and the profile was smoothed by averaging these profiles. After that, the edge of the cup area on the vertical profile was determined by thresholding technique. Lastly, the vertical cup-to-disc ratio was calculated. Using seventy nine images, including twenty five glaucoma images, the sensitivity of 80% and a specificity of 85% were achieved with this method. These results indicated that this method can be useful for the analysis of the optic disc in glaucoma examinations.
Oh, Joo Youn; Park, Ki Ho
2004-01-01
A 51-year-old woman diagnosed as having normal-tension glaucoma developed an acquired pit of the optic nerve. The optic disc was viewed by the Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) before and after development of an acquired pit of the optic nerve. HRT parameters and cross-sectional images of the optic disc were compared. Maximum cup depth at the site of the acquired pit of the optic nerve increased after development of the acquired pit of the optic nerve (from 1.200 to 2.432 mm). The neuroretinal rim area and volume in the inferotemporal octant were reduced (rim area from 0.070 to 0.010 mm2, rim volume from 0.009 to 0.001 mm3). The morphologic changes in the optic disc were also detected topographically and reflectively.
Heidelberg Retina Tomography Analysis in Optic Disks with Anatomic Particularities
Alexandrescu, C; Pascu, R; Ilinca, R; Popescu, V; Ciuluvica, R; Voinea, L; Celea, C
2010-01-01
Due to its objectivity, reproducibility and predictive value confirmed by many large scale statistical clinical studies, Heidelberg Retina Tomography has become one of the most used computerized image analysis of the optic disc in glaucoma. It has been signaled, though, that the diagnostic value of Moorfieds Regression Analyses and Glaucoma Probability Score decreases when analyzing optic discs with extreme sizes. The number of false positive results increases in cases of megalopapilllae and the number of false negative results increases in cases of small size optic discs. The present paper is a review of the aspects one should take into account when analyzing a HRT result of an optic disc with anatomic particularities. PMID:21254731
Arichika, Shigeta; Uji, Akihito; Ooto, Sotaro; Muraoka, Yuki; Yoshimura, Nagahisa
2016-05-01
We compared adaptive optics scanning laser ophthalmoscopy (AOSLO) and optical coherence tomography (OCT) vessel caliber measurements. AOSLO videos were acquired from 28 volunteers with healthy eyes. Artery measurements were made 0.5-1 disc diameters away from the optic disc margin. Individual segmented retinal arterial caliber was measured in synchronization with cardiac pulsation and averaged to obtain final horizontal retinal arterial caliber (ACH) and horizontal retinal arterial lumen (ALH). All OCT images were obtained with the Spectralis OCT, a spectral-domain OCT system. Vertical retinal arterial caliber (ACV) and vertical retinal arterial lumen (ALV) were measured on the same artery measured with AOSLO. Measurements made with the two imaging systems were compared. Average ACH, measured with AOSLO, was 123.4 ± 11.2 and average ALH was 101.8 ± 10.2 µm. Average ACV, measured with OCT, was 125.5 ± 11.4 and average ALV was 99.1 ± 10.6 µm. Both arterial caliber (r = 0.767, p < 0.0001) and arterial lumen (r = 0.81, p < 0.0001) measurements were significantly correlated between imaging modalities. Additionally, ACH and ACV were not significantly different (p = 0.16). However, ALH measurements were significantly higher than ALV measurements (p = 0.03). Vessel measurements made with AOSLO and OCT were well correlated. Moreover, plasma is visible and distinguishable from the retinal vessel wall in AOSLO images but not in OCT images. Therefore, AOSLO may measure vessel width more precisely than OCT.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-06
... via CDX, optical disc (CD or DVD), and paper. Regardless of the method of submission, EPA will require... support documents (including NOCs), though optical discs may continue to be used. Two years after the effective date of this final rule, optical discs will no longer be accepted, and all submitters must submit...
37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.
Code of Federal Regulations, 2012 CFR
2012-07-01
... to identify, maintain, and interpret (e.g., tables in landscape orientation should be identified as landscape orientation or be identified when inquired about) the information on the compact disc. Compact...
37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.
Code of Federal Regulations, 2011 CFR
2011-07-01
... to identify, maintain, and interpret (e.g., tables in landscape orientation should be identified as landscape orientation or be identified when inquired about) the information on the compact disc. Compact...
Morphological Features and Important Parameters of Large Optic Discs for Diagnosing Glaucoma
Okimoto, Satoshi; Yamashita, Keiko; Shibata, Tetsuo; Kiuchi, Yoshiaki
2015-01-01
Purpose To compare the optic disc parameters of glaucomatous eyes to those of non-glaucomatous eyes with large discs. Methods We studied 225 consecutive eyes with large optic discs (>2.82 mm2): 91 eyes with glaucoma and 134 eyes without glaucoma. An eye was diagnosed with glaucoma when visual field defects were detected by the Humphrey Field Analyzer. All of the Heidelberg Retina Tomograph II (HRT II) parameters were compared between the non-glaucomatous and glaucomatous eyes. A logistic regression analysis of the HRT II parameters was used to establish a new formula for diagnosing glaucoma, and the sensitivity and specificity of the Moorfields Regression Analysis (MRA) was compared to the findings made by our analyses. Results The mean disc area was 3.44±0.50 mm2 in the non-glaucomatous group and 3.40±0.52 mm2 in the glaucoma group. The cup area, cup volume, cup-to-disc area ratio, linear cup/disc ratio, mean cup depth, and the maximum cup depth were significantly larger in glaucomatous eyes than in the non-glaucomatous eyes. The rim area, rim volume, cup shape measurement, mean retinal nerve fiber layer (RNFL) thickness, and RFNL cross-sectional area were significantly smaller in glaucomatous eyes than in non-glaucomatous eyes. The cup-to-disc area ratio, the height variation contour (HVC), and the RNFL cross-sectional area were important parameters for diagnosing the early stage glaucoma, and the cup-to-disc area ratio and cup volume were useful for diagnosing advanced stage glaucoma in eyes with a large optic disc. The new formula had higher sensitivity and specificity for diagnosing glaucoma than MRA. Conclusions The cup-to-disc area ratio, HVC, RNFL cross-sectional area, and cup volume were important parameters for diagnosing glaucoma in eyes with a large optic disc. The important disc parameters to diagnose glaucoma depend on the stage of glaucoma in patients with large discs. PMID:25798580
Morphometric Study of the Lumbar Posterior Longitudinal Ligament
Lee, Sang Beom; Chang, Jae Chil; Lee, Gwang Soo; Hwang, Jae Chan; Bae, Hack Gun; Doh, Jae Won
2018-01-01
Objective Morphometric data for the lumbar posterior longitudinal ligament (PLL) was investigated to identify whether there is a difference in the morphometry of the PLL of the lumbar spine at each level with respect to the pattern of intervertebral disc displacement. Methods In 14 formalin-fixed adult cadavers (12 males and 2 females), from L1 to L5, the authors measured the width and height of the PLL and compared them with other landmarks such as the disc and the pedicle. Results Horizontally, at the upper margin of the disc, the central portion of the superficial PLL covered 17.8–36.9% of the disc width and the fan-like portion of the PLL covered 63.9–76.7% of the disc width. At the level of the median portion of the disc, the PLL covered 69.1–74.5% of the disc width. Vertically, at the level of the medial margin of the pedicle, the fan-like portion of the PLL covered 23.5–29.9% of the disc height. In general, a significant difference in length was not found in the right-left and male-female comparisons. Conclusion This study presents the morphometric data on the pattern of intervertebral disc displacement and helps to improve the knowledge of the surgical anatomy of the lumbar PLL. PMID:29354240
Kumar, Addepalli U.; Jonnadula, Ganesh B.; Garudadri, Chandrasekhar; Rao, Harsha L.; Senthil, Sirisha; Papas, Eric B.; Sankaridurg, Padmaja; Khanna, Rohit C.
2013-01-01
Purpose To compare the diagnostic performance of glaucoma specialists and experienced optometrists in gonioscopy and optic disc assessment. Methods This study was done to validate the diagnostic performance of two experienced optometrists for using their skills of detecting glaucoma using gonioscopy and optic disc assessment in a major epidemiological study, the L V Prasad Eye Institute Glaucoma Epidemiology and Molecular Genetics Study (LVPEI-GLEAMS). Gonioscopic findings for 150 eyes were categorized as 0, 1 and 2 for open angle, primary angle closure suspect (PACS) and primary angle closure (PAC) respectively. Optic disc findings for 200 eyes were categorized as 0, 1 and 2 for normal, suspects and glaucomatous respectively. Weighted kappa (κ) and diagnostic accuracy parameters were calculated. Two optometrists (#1 and #2) participated in the study. Results Agreement between glaucoma specialists and optometrist for interpretation of gonioscopy to discriminate PACS and PAC from open angles and for interpretation of optic disc to discriminate glaucomatous and suspicious discs from normal, the kappa (κ) was 0.92 and 0.84 and 0.90 and 0.89 for optometrists #1 and #2 respectively. Sensitivities and specificities were above 90% for gonioscopy. Optic disc evaluation had specificities greater than 95% to discriminate normal from glaucomatous discs while the sensitivities were 83% and 93% for optometrists #1 and #2 respectively. Conclusion Agreement between optometrists and glaucoma specialists, in diagnostic performance of gonioscopy and optic assessment was excellent with high sensitivity and specificity. Hence, we conclude that the experienced optometrists can detect glaucoma accurately in the LVPEI-GLEAMS.
Terson syndrome and leukemia: a case report
Lorenzi, Umberto; Buschini, Elisa; Fea, Antonio; Machetta, Federica; Grignolo, Federico Maria
2014-01-01
Background Terson syndrome is defined as intraocular hemorrhage associated with intracranial bleeding. This syndrome can occur in the event of intracranial hemorrhage or elevated intracranial pressure. To our knowledge, it has never been associated with chronic myeloid leukemia. A 45-year-old woman suffering from chronic myeloid leukemia was referred to our clinic with Terson syndrome after intracranial bleeding. We followed this patient for a year, performing visual acuity assessment, fundus examination, color retinography, and A-scan and B-scan ultrasonography. At presentation, her best-corrected visual acuity on the right was 20/63 and on the left was 20/320. In the right eye, retinoscopy showed blurring of the optic margins surrounded by retinal and preretinal hemorrhages, preretinal fibrosis of the optic disc along the vascular arcades, and perivascular retinal infiltrates. In the left eye, the optic disc was surrounded by retinal and preretinal hemorrhages, and massive fibrosis with hard exudates and severe preretinal hemorrhage were observed at the posterior pole. Roth spots and many circular hemorrhages were noted at the periphery of the retina. A-scan and B-scan ultrasonography did not show intraocular leukemic infiltration. The clinical picture remained stable over the following 12 months. In this patient, we observed the ophthalmoscopic features of chronic myeloid leukemia, but also coexistence of features typical of Terson syndrome. To our knowledge, no similar cases have been reported previously. PMID:24729684
Takayama, Kohei; Ooto, Sotaro; Hangai, Masanori; Arakawa, Naoko; Oshima, Susumu; Shibata, Naohisa; Hanebuchi, Masaaki; Inoue, Takashi; Yoshimura, Nagahisa
2012-01-01
To conduct high-resolution imaging of the retinal nerve fiber layer (RNFL) in normal eyes using adaptive optics scanning laser ophthalmoscopy (AO-SLO). AO-SLO images were obtained in 20 normal eyes at multiple locations in the posterior polar area and a circular path with a 3-4-mm diameter around the optic disc. For each eye, images focused on the RNFL were recorded and a montage of AO-SLO images was created. AO-SLO images for all eyes showed many hyperreflective bundles in the RNFL. Hyperreflective bundles above or below the fovea were seen in an arch from the temporal periphery on either side of a horizontal dividing line to the optic disc. The dark lines among the hyperreflective bundles were narrower around the optic disc compared with those in the temporal raphe. The hyperreflective bundles corresponded with the direction of the striations on SLO red-free images. The resolution and contrast of the bundles were much higher in AO-SLO images than in red-free fundus photography or SLO red-free images. The mean hyperreflective bundle width around the optic disc had a double-humped shape; the bundles at the temporal and nasal sides of the optic disc were narrower than those above and below the optic disc (P<0.001). RNFL thickness obtained by optical coherence tomography correlated with the hyperreflective bundle widths on AO-SLO (P<0.001) AO-SLO revealed hyperreflective bundles and dark lines in the RNFL, believed to be retinal nerve fiber bundles and Müller cell septa. The widths of the nerve fiber bundles appear to be proportional to the RNFL thickness at equivalent distances from the optic disc.
Optic disc detection and boundary extraction in retinal images.
Basit, A; Fraz, Muhammad Moazam
2015-04-10
With the development of digital image processing, analysis and modeling techniques, automatic retinal image analysis is emerging as an important screening tool for early detection of ophthalmologic disorders such as diabetic retinopathy and glaucoma. In this paper, a robust method for optic disc detection and extraction of the optic disc boundary is proposed to help in the development of computer-assisted diagnosis and treatment of such ophthalmic disease. The proposed method is based on morphological operations, smoothing filters, and the marker controlled watershed transform. Internal and external markers are used to first modify the gradient magnitude image and then the watershed transformation is applied on this modified gradient magnitude image for boundary extraction. This method has shown significant improvement over existing methods in terms of detection and boundary extraction of the optic disc. The proposed method has optic disc detection success rate of 100%, 100%, 100% and 98.9% for the DRIVE, Shifa, CHASE_DB1, and DIARETDB1 databases, respectively. The optic disc boundary detection achieved an average spatial overlap of 61.88%, 70.96%, 45.61%, and 54.69% for these databases, respectively, which are higher than currents methods.
Bayır, Şafak
2016-01-01
With the advances in the computer field, methods and techniques in automatic image processing and analysis provide the opportunity to detect automatically the change and degeneration in retinal images. Localization of the optic disc is extremely important for determining the hard exudate lesions or neovascularization, which is the later phase of diabetic retinopathy, in computer aided eye disease diagnosis systems. Whereas optic disc detection is fairly an easy process in normal retinal images, detecting this region in the retinal image which is diabetic retinopathy disease may be difficult. Sometimes information related to optic disc and hard exudate information may be the same in terms of machine learning. We presented a novel approach for efficient and accurate localization of optic disc in retinal images having noise and other lesions. This approach is comprised of five main steps which are image processing, keypoint extraction, texture analysis, visual dictionary, and classifier techniques. We tested our proposed technique on 3 public datasets and obtained quantitative results. Experimental results show that an average optic disc detection accuracy of 94.38%, 95.00%, and 90.00% is achieved, respectively, on the following public datasets: DIARETDB1, DRIVE, and ROC. PMID:27110272
Chen, Li-Wei; Lan, Yu-Wen; Hsieh, Jui-Wen
2016-06-01
To evaluate the morphologic characteristics of optic neuropathy and its association with visual field (VF) defects in primary open-angle glaucoma (POAG) eyes with high myopia. In this cross-sectional study, we reviewed data from 375 Taiwanese patients (375 eyes) of POAG, ages 20 to 60 years. Optic disc photographs were used for planimetric measurements of morphologic variables. The myopic refraction was divided into high myopia (<-6.0 D) and nonhigh myopia (moderate myopia to hyperopia). The optic disc area was classified as moderate (1.59 to 2.85 mm), large, and small. Differences in characteristics between groups, correlations with the disc area, and factors associated with VF defects were determined. Of the 142 highly myopic eyes, 33 (23%) had a large disc, 26 (18%) had a small disc, and 55 (39%) had a tilted disc. Large discs had a higher cup-to-disc (C/D) area ratio and a higher tilt ratio; small discs had a smaller rim area and a lower tilt ratio (all P<0.05). Characteristics associated with high myopia included a smaller rim area, a higher C/D area ratio, and a lower tilt ratio (all P<0.001). In logistic regression, the refraction, the C/D area ratio, the rim area, and the tilt ratio (all P<0.05) were associated with VF defects. In Taiwanese individuals with POAG, our study found that tilted, large, or small discs were prevalent in highly myopic eyes. Of these characteristics, only the disc tilt and high myopia by itself were associated with the severity of glaucomatous optic neuropathy.
NASA Astrophysics Data System (ADS)
Kokubo, Mitsuru
2015-05-01
The physical mechanisms of the quasar ultraviolet (UV)-optical variability are not well understood despite the long history of observations. Recently, Dexter & Agol presented a model of quasar UV-optical variability, which assumes large local temperature fluctuations in the quasar accretion discs. This inhomogeneous accretion disc model is claimed to describe not only the single-band variability amplitude, but also microlensing size constraints and the quasar composite spectral shape. In this work, we examine the validity of the inhomogeneous accretion disc model in the light of quasar UV-optical spectral variability by using five-band multi-epoch light curves for nearly 9 000 quasars in the Sloan Digital Sky Survey (SDSS) Stripe 82 region. By comparing the values of the intrinsic scatter σint of the two-band magnitude-magnitude plots for the SDSS quasar light curves and for the simulated light curves, we show that Dexter & Agol's inhomogeneous accretion disc model cannot explain the tight inter-band correlation often observed in the SDSS quasar light curves. This result leads us to conclude that the local temperature fluctuations in the accretion discs are not the main driver of the several years' UV-optical variability of quasars, and consequently, that the assumption that the quasar accretion discs have large localized temperature fluctuations is not preferred from the viewpoint of the UV-optical spectral variability.
High-density near-field optical disc recording using phase change media and polycarbonate substrate
NASA Astrophysics Data System (ADS)
Shinoda, Masataka; Saito, Kimihiro; Ishimoto, Tsutomu; Kondo, Takao; Nakaoki, Ariyoshi; Furuki, Motohiro; Takeda, Minoru; Akiyama, Yuji; Shimouma, Takashi; Yamamoto, Masanobu
2004-09-01
We developed a high density near field optical recording disc system with a solid immersion lens and two laser sources. In order to realize the near field optical recording, we used a phase change recording media and a molded polycarbonate substrate. The near field optical pick-up consists of a solid immersion lens with numerical aperture of 1.84. The clear eye pattern of 90.2 GB capacity (160nm track pitch and 62 nm per bit) was observed. The jitter using a limit equalizer was 10.0 % without cross-talk. The bit error rate using an adaptive PRML with 8 taps was 3.7e-6 without cross-talk. We confirmed that the near field optical disc system is a promising technology for a next generation high density optical disc system.
Zang, Pengxiao; Gao, Simon S; Hwang, Thomas S; Flaxel, Christina J; Wilson, David J; Morrison, John C; Huang, David; Li, Dengwang; Jia, Yali
2017-03-01
To improve optic disc boundary detection and peripapillary retinal layer segmentation, we propose an automated approach for structural and angiographic optical coherence tomography. The algorithm was performed on radial cross-sectional B-scans. The disc boundary was detected by searching for the position of Bruch's membrane opening, and retinal layer boundaries were detected using a dynamic programming-based graph search algorithm on each B-scan without the disc region. A comparison of the disc boundary using our method with that determined by manual delineation showed good accuracy, with an average Dice similarity coefficient ≥0.90 in healthy eyes and eyes with diabetic retinopathy and glaucoma. The layer segmentation accuracy in the same cases was on average less than one pixel (3.13 μm).
Zang, Pengxiao; Gao, Simon S.; Hwang, Thomas S.; Flaxel, Christina J.; Wilson, David J.; Morrison, John C.; Huang, David; Li, Dengwang; Jia, Yali
2017-01-01
To improve optic disc boundary detection and peripapillary retinal layer segmentation, we propose an automated approach for structural and angiographic optical coherence tomography. The algorithm was performed on radial cross-sectional B-scans. The disc boundary was detected by searching for the position of Bruch’s membrane opening, and retinal layer boundaries were detected using a dynamic programming-based graph search algorithm on each B-scan without the disc region. A comparison of the disc boundary using our method with that determined by manual delineation showed good accuracy, with an average Dice similarity coefficient ≥0.90 in healthy eyes and eyes with diabetic retinopathy and glaucoma. The layer segmentation accuracy in the same cases was on average less than one pixel (3.13 μm). PMID:28663830
Woo, Se Joon; Kim, Mi Jeung; Park, Kyu Hyung; Lee, Yun Jong; Hwang, Jeong-Min
2012-02-01
A 13-year-old male and a 15-year-old female presented with optic disc edema associated with chronic recurrent uveitis. While the ocular inflammation responded to high doses of oral prednisolone, the disc edema showed little improvement. After oral administration of methotrexate, the disc edema and ocular inflammation were resolved, and the dose of oral corticosteroid could be reduced.
[Maculopathy in case of the pit of the disc].
Kolár, P
2005-09-01
The pit of the disc is a congenital anomaly of the optic nerve disc. The prevalence is 1/11 000 patients. On the affected side, the optic disc is in 85% of cases larger than the disc of the other healthy eye. The pit of the disc is very often associated with the presence of the cilioretinal artery. Maculopathy in congenital pit of the optic nerve disc was described in the early 30's of the last century by Calhoun. The average age of the patients is roughly 30 years of age (20-40 years). The complementary examination method, which may help to clarify anatomical conditions of the macular region, is the optical coherence tomography. The defect of the optic disc of different depth caused by the pit and maculopathy caused by retinoschisis communicating with the temporal rim of the disc are found. This case report refers to a 29 years old man with disturbing relative central scotoma and decreased vision for one month in his right eye, who underwent classical three-ports pars plana vitrectomy with expansive gas tamponade. On the basis of differential diagnosis discretion, the temporally localized pit of the disc accompanied by maculopathy due to retonoschisis was detemined. The surgical treatment by means of three-ports pars plana vitrectomy and peeling of the inner limiting membrane with expansive gas tamponade restored in our patient the physiological macular structure followed by improvement of the best-corrected visual acuity. No complications were noticed during the surgery or after it as well. Among the differential diagnoses, it is necessary to eliminate other possible causes of maculopathy in young patients as well as other congenital anomalies of the optic disc, which may be related to the maculopathy. Maculopathy following the pit of the optic nerve disc represents relatively rare diagnostic entity. According to the literature, the natural course of this disease results in very low final best-corrected visual acuity, often worse than 5/50 (0,1 or 20/200). The therapeutic possibility for patients with this disease is operative approach by means of pars plana vitrectomy with peeling of the inner limiting membrane and accompanied by expansive gas tamponade as already mentioned in our case report.
Specific Location of Disc Hemorrhage is Linked to Nerve Fiber Layer Defects.
Yoo, Young Cheol; Kim, Joon Mo; Park, Han Seok; Yoo, Chungkwon; Shim, Seong Hee; Won, Yu Sam; Park, Ki Ho; Chang, Robert T
2017-06-01
To investigate the relationship between retinal nerve fiber layer (RNFL) defects and the quadrant and proximal location of disc hemorrhages (DHs) in a large population examined for health screening. A total of 168,044 subjects older than 20 years underwent a single screening ophthalmic examination with color fundus photography as part of a comprehensive health screening program. The presence and location of DHs and RNFL defects were assessed. The DH locations were defined according to the quadrant location (inferotemporal, superotemporal, inferonasal, or superonasal) and the most proximal end of DHs relative to the disc center (cup base, cup margin, disc rim, or extrapapillary region). Using these two location descriptors as independent variables, a logistic regression analysis was conducted to explore the effects of DH location on RNFL defects. Two hundred twenty-six eyes had DH and 120 (53.1%) of them had RNFL defects. After adjusting for proximal location, DHs located in the inferotemporal quadrant accompanied RFNL defects 12 times more frequently than those in the superonasal quadrant (odds ratio [OR], 11.81; P = .004). Conversely, after adjusting for quadrant location, the ORs for an associated RNFL defect were 3.73 (P < .001), 16.54 (P < .001), and 8.91 (P = .002) for DHs with the proximal end at the disc rim, cup margin, and cup base, respectively. Among the four quadrants and four proximal locations, DHs were identified most frequently in the inferotemporal quadrant and outside the disc, respectively. Some DH locations, such as the inferotemporal quadrant and the cup margin, were associated with RNFL defects, whereas others were not.
Artes, Paul H; Crabb, David P
2010-01-01
To investigate why the specificity of the Moorfields Regression Analysis (MRA) of the Heidelberg Retina Tomograph (HRT) varies with disc size, and to derive accurate normative limits for neuroretinal rim area to address this problem. Two datasets from healthy subjects (Manchester, UK, n = 88; Halifax, Nova Scotia, Canada, n = 75) were used to investigate the physiological relationship between the optic disc and neuroretinal rim area. Normative limits for rim area were derived by quantile regression (QR) and compared with those of the MRA (derived by linear regression). Logistic regression analyses were performed to quantify the association between disc size and positive classifications with the MRA, as well as with the QR-derived normative limits. In both datasets, the specificity of the MRA depended on optic disc size. The odds of observing a borderline or outside-normal-limits classification increased by approximately 10% for each 0.1 mm(2) increase in disc area (P < 0.1). The lower specificity of the MRA with large optic discs could be explained by the failure of linear regression to model the extremes of the rim area distribution (observations far from the mean). In comparison, the normative limits predicted by QR were larger for smaller discs (less specific, more sensitive), and smaller for larger discs, such that false-positive rates became independent of optic disc size. Normative limits derived by quantile regression appear to remove the size-dependence of specificity with the MRA. Because quantile regression does not rely on the restrictive assumptions of standard linear regression, it may be a more appropriate method for establishing normative limits in other clinical applications where the underlying distributions are nonnormal or have nonconstant variance.
Optical effects related to Keplerian discs orbiting Kehagias-Sfetsos naked singularities
NASA Astrophysics Data System (ADS)
Stuchlík, Zdeněk; Schee, Jan
2014-10-01
We demonstrate possible optical signatures of the Kehagias-Sfetsos (KS) naked singularity spacetimes representing a spherically symmetric vacuum solution of the modified Hořava gravity. In such spacetimes, accretion structures significantly different from those present in standard black hole spacetimes occur due to the ‘antigravity’ effect, which causes an internal static sphere surrounded by Keplerian discs. We focus our attention on the optical effects related to the Keplerian accretion discs, constructing the optical appearance of the Keplerian discs, the spectral continuum due to their thermal radiation, and the spectral profiled lines generated in the innermost parts of such discs. The KS naked singularity signature is strongly encoded in the characteristics of predicted optical effects, especially in cases where the spectral continuum and spectral lines are profiled by the strong gravity of the spacetimes due to the vanishing region of the angular velocity gradient influencing the effectiveness of the viscosity mechanism. We can conclude that optical signatures of KS naked singularities can be well distinguished from the signatures of standard black holes.
Design and implementation of optical system for Placido-disc topography
NASA Astrophysics Data System (ADS)
Sui, Chenghua; Wo, Shengjie; Cai, Pinggen; Gao, Nan; Xu, Danyang; Han, Yonghao; Du, Chunnian
2017-11-01
Corneal topography provides powerful support in the diagnosis and treatment of corneal disease by displaying the corneal surface topography in data or image format. To realize the precise detection of corneal surface topography, an optical system for the corneal topography that is based on a Placido disc is designed, which includes a ring distribution on a Placido disc, an imaging system and a collimating illumination system. First, a mathematical model that is based on the corneal topography working principles is established with MATLAB to determine the distribution of white-and-black rings on the Placido disc, in which the ellipsoid facial rings-target of the Placido disc is utilized. Second, the imaging lens structure is designed and optimized by Zemax software. Last, the collimating illumination lens structure is designed by paraxial ray trace equations. The quality of the corneal topography, which is based on our designed optical system, is evaluated. The high-contrast image of uniformly distributed white-and-black rings is observed through the CCD camera. Our optical system for the corneal topography has high precision, with a measuring region of the cornea with a diameter of approximately 10 mm. Therefore, the creation of this optical system offers guidance for designing and improving the optical system of Placido-disc topography.
Yang, Qing-Song; Yu, Ya-Jie; Li, Shu-Ning; Liu, Juan; Hao, Ying-Juan
2012-08-01
Copernicus optical coherence tomography (SOCT) is a new, ultra high-speed and high-resolution instrument available for clinical evaluation of optic nerve. The purpose of the study was to compare the agreements between SOCT and Heidelberg retinal tomography (HRT). A total of 44 healthy normal volunteers were recruited in this study. One eye in each subject was selected randomly. Agreement between SOCT and HRT-3 in measuring optic disc area was assessed using Bland-Altman plots. Relationships between measurements of optic nerve head parameter obtained by SOCT and HRT-3 were assessed by Pearson correlation. There was no significant difference in the average cup area (0.306 vs. 0.355 mm, P = 0.766), cup volume (0.158 vs. 0.130 mm, P = 0.106) and cup/disc ration (0.394 vs. 0.349 mm, P = 0.576) measured by the two instruments. However, other optic disc parameters from SOCT were significantly lower compared with HRT-3. The Bland-Altman plot revealed good agreement of cup area and cup volume measured by SOCT and HRT-3. Bad agreement of disc area, rim area, rim volume and cup/disc ratio were found between SOCT and HRT-3. The highest correlations between the two instruments were observed for cup area (r(2) = 0.783, P = 0.000) and cup/disc ratio (r(2) = 0.669, P = 0.000), whereas the lowest correlation was observed for disc area (r(2) = 0.100, P = 0.037), rim area (r(2) = 0.275, P = 0.000), cup volume (r(2) = 0.005, P = 0.391) and rim volume (r(2) = 0.021, P = 0.346). There were poor agreements between SOCT and HRT-3 for measurement of optic nerve parameters except cup area and cup volume. Measurement results of the two instruments are not interchangeable.
Kim, Mi Jeung; Park, Kyu Hyung; Lee, Yun Jong; Hwang, Jeong-Min
2012-01-01
A 13-year-old male and a 15-year-old female presented with optic disc edema associated with chronic recurrent uveitis. While the ocular inflammation responded to high doses of oral prednisolone, the disc edema showed little improvement. After oral administration of methotrexate, the disc edema and ocular inflammation were resolved, and the dose of oral corticosteroid could be reduced. PMID:22323889
NASA Astrophysics Data System (ADS)
Romeo, Alessandro B.; Mogotsi, Keoikantse Moses
2017-07-01
The velocity dispersion of cold interstellar gas, σ, is one of the quantities that most radically affect the onset of gravitational instabilities in galaxy discs, and the quantity that is most drastically approximated in stability analyses. Here we analyse the stability of a large sample of nearby star-forming spirals treating molecular gas, atomic gas and stars as three distinct components, and using radial profiles of σCO and σ _{H I} derived from HERA CO-Line Extragalactic Survey (HERACLES) and The H I Nearby Galaxy Survey (THINGS) observations. We show that the radial variations of σCO and σ _{H I} have a weak effect on the local stability level of galaxy discs, which remains remarkably flat and well above unity, but is low enough to ensure (marginal) instability against non-axisymmetric perturbations and gas dissipation. More importantly, the radial variation of σCO has a strong impact on the size of the regions over which gravitational instabilities develop, and results in a characteristic instability scale that is one order of magnitude larger than the Toomre length of molecular gas. Disc instabilities are driven, in fact, by the self-gravity of stars at kiloparsec scales. This is true across the entire optical disc of every galaxy in the sample, with a few exceptions. In the linear phase of the disc-instability process, stars and molecular gas are strongly coupled, and it is such a coupling that ultimately triggers local gravitational collapse/fragmentation in the molecular gas.
Mader, Thomas H; Gibson, C Robert; Otto, Christian A; Sargsyan, Ashot E; Miller, Neil R; Subramanian, Prem S; Hart, Stephen F; Lipsky, William; Patel, Nimesh B; Lee, Andrew G
2017-06-01
Several ophthalmic findings including optic disc swelling, globe flattening and choroidal folds have been observed in astronauts following long-duration space flight. The authors now report asymmetric choroidal expansion, disc swelling and optic disc morphologic changes in a 45-year-old astronaut which occurred during long-duration space flight and persisted following his space mission. Case study of ocular findings in an astronaut documented during and after a long-duration space flight of approximately 6 months. Before, during and after his spaceflight, he underwent complete eye examination, including fundus photography, ultrasound, and optical coherence tomography. We documented asymmetric choroidal expansion inflight that largely resolved by 30 days postflight, asymmetric disc swelling observed inflight that persisted for over 180 days postflight, asymmetric optic disc morphologic changes documented inflight by OCT that persisted for 630 days postflight and asymmetric globe flattening that began inflight and continued 660 days postflight. Lumbar puncture opening pressures obtained at 7 and 365 days post-mission were 22 and 16 cm H20 respectively. The persistent asymmetric findings noted above, coupled with the lumbar puncture opening pressures, suggest that prolonged microgravity exposure may have produced asymmetric pressure changes within the perioptic subarachnoid space.
37 CFR 1.52 - Language, paper, writing, margins, compact disc specifications.
Code of Federal Regulations, 2010 CFR
2010-07-01
... cm (3/4 inch), a left side margin of at least 2.5 cm (1 inch), a right side margin of at least 2.0 cm... brackets should appear to the right of the left margin as the first item in each paragraph, before the... elements, and should not be independently numbered. If a nontext element extends to the left margin, it...
Terai, Naim; Spoerl, Eberhard; Pillunat, Lutz E; Kuhlisch, Eberhard; Schmidt, Eckart; Boehm, Andreas G
2011-09-01
To investigate the relationship between central corneal thickness (CCT) and optic disc size in patients with primary open-angle glaucoma (POAG) in a hospital-based population. Data for the right eyes of 1435 White patients with POAG were included in a retrospective hospital-based study. All eyes underwent optic nerve head imaging using Heidelberg Retina Tomograph II (HRT II; Heidelberg Engineering, Heidelberg, Germany) and CCT measurement by ultrasound corneal pachymetry. Eyes with prior intraocular or corneal surgery were excluded. Low-quality HRT II images were also excluded. The impact of age, gender, CCT, intraocular pressure, cylindrical and spherical refractive error as independent factors on optic disc size was investigated in a multiple linear regression analysis. The data for 1104 right eyes qualified for participation in the study. The median age of these patients was 65 years. The median CCT was 547 μm (25th-75th percentile 522-575 μm). The median optic disc size was 2.21 mm(2) (25th-75th percentile 1.89-2.60 mm(2)). Multiple linear regression analysis revealed that age (p = 0.001), CCT (p = 0.001) and spherical equivalent (p = 0.049) were correlated to disc size according to the following formula: disc area = -0.004 × age - 0.001 × CCT - 0.014 × spherical equivalent +3.290. R(2) of the whole model was 0.021. Univariate regression analysis between age and disc area provided R(2) = 0.008 with p = 0.002. Univariate regression analysis between disc area and CCT provided R(2) = 0.005 with p = 0.02. In this retrospective hospital-based study we could not detect a clinically relevant correlation between optic disc size and CCT. The correlation between CCT and disc size and between age and disc size were statistically significant, but the R(2) values were very low. The results of the study are biased because of its hospital-based design, so the results of the study need to be confirmed in a large population-based study. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.
Optic disc pit with sectorial retinitis pigmentosa.
Balikoglu-Yilmaz, Melike; Taskapili, Muhittin; Yilmaz, Tolga; Teke, Mehmet Yasin
2013-01-01
Sectorial retinitis pigmentosa (RP) and optic disc pit (ODP) are rare clinical conditions. We present a 40-year-old woman with a history of mild night blindness and decreased vision in the right eye for about 5 years. Fundus examination revealed retinal pigmentary changes in the superior and inferotemporal sectors covering the macula and reduced arterial calibre and ODP at the temporal edge of the optic disc. In addition, fundus autofluorescence, spectral-domain optical coherence tomography, fluorescein angiography, and multifocal electroretinogram scans confirmed these clinical findings. Visual acuity was decreased due to an atrophic-appearing foveal lesion. No intervention was suggested because of the poor visual potential. To the best of our knowledge, the present study is the first to describe coexistent optic disc pit and sectorial RP in the superior and inferotemporal sectors covering the macula in the same eye with figures.
NASA Astrophysics Data System (ADS)
Rigon, Laura
2016-03-01
Stars form from the collapse of molecular clouds and evolve in an environment rich in gas and dust before becoming Main Sequence stars. During this phase, characterised by the presence of a protoplanetary disc, stars manifest changes in the structure and luminosity. This thesis performs a multi-wavelength analysis, from optical to mm range, on a sample of young stars (YSOs), mainly Classical T Tauri (CTTS). The purpose is to study optical and infrared variability and its relation with the protoplanetary disc. Longer wavelength, in the mm range, are used instead to investigate the evolution of the disc, in terms of dust growth. In optical, an F-test on a sample of 39 CTTS reveals that 67% of the stars are variable. The variability, quantified through pooled sigma, is visible both in magnitude amplitudes and changes over time. Time series analysis applied on the more variable stars finds the presence of quasi periodicity, with periods longer than two weeks, interpreted either as eclipsing material in the disc happening on a non-regular basis, or as a consequence of star-disc interaction via magnetic field lines. The variability of YSOs is confirmed also in infrared, even if with lower amplitude. No strong correlations are found between optical and infrared variability, which implies a different cause or a time shift in the two events. By using a toy model to explore their origin, I find that infrared variations are likely to stem from emissions in the inner disc. The evolution of discs in terms of dust growth is confirmed in most discs by the analysis of the slope of the spectral energy distribution (SED), after correcting for wind emission and optical depth effects. However, the comparison with a radiative transfer model highlights that a number of disc parameters, in particular disc masses and temperature, dust size distribution and composition, can also affect the slope of the SED.
Optic nerve axons and acquired alterations in the appearance of the optic disc.
Wirtschafter, J D
1983-01-01
The pathophysiologic events in optic nerve axons have recently been recognized as crucial to an understanding of clinically significant acquired alterations in the ophthalmoscopic appearance of the optic disc. Stasis and related abnormalities of axonal transport appear to explain most aspects of optic nerve head swelling, including optic disc drusen and retinal cottonwool spots. Loss of axoplasm and axonal death can be invoked to interpret optic disc pallor, thinning and narrowing of rim tissue, changes in the size and outline of the optic cup, laminar dots, atrophy of the retinal nerve fiber layer, and acquired demyelination and myelination of the retinal nerve fiber layer. It is speculated that the axons may also play a role in the mechanical support of the lamina cribrosa in resisting the pressure gradient across the pars scleralis of the optic nerve head. Axons and their associated glial cells may be involved in those cases where "reversibility" of cupping of the optic disc has been reported. The structure, physiology, and experimental pathologic findings of the optic nerve head have been reviewed. Many aspects concerning the final anatomic appearance of the optic nerve head have been explained. However, many questions remain concerning the intermediate mechanisms by which increased intracranial pressure retards the various components of axonal transport in papilledema and by which increased IOP causes axonal loss in glaucoma. Investigation of the molecular biology of axonal constituents and their responses to abnormalities in their physical and chemical milieu could extend our understanding of the events that result from mechanical compression and local ischemia. Moreover, we have identified a need to further explore the role of axons in the pathophysiology of optic disc cupping. Images FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6 FIGURE 7 FIGURE 8 FIGURE 11 FIGURE 12 FIGURE 13 PMID:6203209
A detailed look at the cytoskeletal architecture of the Giardia lamblia ventral disc.
Brown, Joanna R; Schwartz, Cindi L; Heumann, John M; Dawson, Scott C; Hoenger, Andreas
2016-04-01
Giardia lamblia is a protistan parasite that infects and colonizes the small intestine of mammals. It is widespread and particularly endemic in the developing world. Here we present a detailed structural study by 3-D negative staining and cryo-electron tomography of a unique Giardia organelle, the ventral disc. The disc is composed of a regular array of microtubules and associated sheets, called microribbons that form a large spiral, held together by a myriad of mostly unknown associated proteins. In a previous study we analyzed by cryo-electron tomography the central microtubule portion (here called disc body) of the ventral disc and found a large portion of microtubule associated inner (MIPs) and outer proteins (MAPs) that render these microtubules hyper-stable. With this follow-up study we expanded our 3-D analysis to different parts of the disc such as the ventral and dorsal areas of the overlap zone, as well as the outer disc margin. There are intrinsic location-specific characteristics in the composition of microtubule-associated proteins between these regions, as well as large differences between the overall architecture of microtubules and microribbons. The lateral packing of microtubule-microribbon complexes varies substantially, and closer packing often comes with contracted lateral tethers that seem to hold the disc together. It appears that the marginal microtubule-microribbon complexes function as outer, laterally contractible lids that may help the cell to clamp onto the intestinal microvilli. Furthermore, we analyzed length, quantity, curvature and distribution between different zones of the disc, which we found to differ from previous publications. Copyright © 2016 Elsevier Inc. All rights reserved.
Dias, Diego T; Ushida, Michele; Sousa, Marina C; Dorairaj, Syril; Biteli, Luis G; Leite, Mauro T; Paranhos, Augusto; Prata, Tiago S
2016-01-01
Among all glaucoma suspects, eyes with optic nerve head features suspicious or suggestive of early glaucoma are probably those that offer the greatest challenge for clinicians. In contrast with the robust longitudinal data published on ocular hypertension, there is no specific management guideline for these patients. Therefore, evaluating eyes with suspicious optic disc appearance and normal intraocular pressure (IOP), we sought to investigate potential differences in clinical and epidemiological characteristics to differentiate those with normal-tension glaucoma (NTG) from those with presumed large physiological optic disc cups (pLPC). In this observational case-control study, we consecutively enrolled individuals with pLPC and NTG. All eyes had vertical cup-to-disc ratio (VCDR)≥0.6 and untreated IOP<21 mmHg. Glaucomatous eyes had reproducible visual field defects. Eyes with pLPC required normal visual fields and ≥30 months of follow-up with no evidence of glaucomatous neuropathy. Clinical and epidemiological parameters were compared between groups. Eighty-four individuals with pLPC and 40 NTG patients were included. Regarding our main results, NTG patients were significantly older and with a higher prevalence of Japanese descendants (p<0.01). Not only did pLPC eyes have smaller mean VCDR, but also larger optic discs (p≤0.04). There were no significant differences for gender, central corneal thickness, and spherical equivalent (p≥0.38). Significant odds ratios (OR) were found for race (OR = 2.42; for Japanese ancestry), age (OR = 1.05), VCDR (OR = 5.03), and disc size (OR = 0.04; p≤0.04). In conclusion, in patients with suspicious optic disc and normal IOP, those with older age, Japanese ancestry, smaller optic discs, and larger VCDR are more likely to have NTG, and therefore, deserve deeper investigation and closer monitoring.
A compact disc under skimming light rays
NASA Astrophysics Data System (ADS)
De Luca, R.; Di Mauro, M.; Fiore, O.; Naddeo, A.
2018-03-01
The optical properties of a compact disc (CD) under "skimming" light rays have been analyzed. We have noticed that a clear green line can be detected when the disc is irradiated with light rays coming from a lamp in such a way that only those skimming the CD, held horizontally, are selected. We provide a physical interpretation of this phenomenon on the basis of elementary optics concepts. Extension of these concepts to digital versatile discs (DVDs) is given.
Optic Disc Pit with Sectorial Retinitis Pigmentosa
Taskapili, Muhittin; Yilmaz, Tolga; Teke, Mehmet Yasin
2013-01-01
Sectorial retinitis pigmentosa (RP) and optic disc pit (ODP) are rare clinical conditions. We present a 40-year-old woman with a history of mild night blindness and decreased vision in the right eye for about 5 years. Fundus examination revealed retinal pigmentary changes in the superior and inferotemporal sectors covering the macula and reduced arterial calibre and ODP at the temporal edge of the optic disc. In addition, fundus autofluorescence, spectral-domain optical coherence tomography, fluorescein angiography, and multifocal electroretinogram scans confirmed these clinical findings. Visual acuity was decreased due to an atrophic-appearing foveal lesion. No intervention was suggested because of the poor visual potential. To the best of our knowledge, the present study is the first to describe coexistent optic disc pit and sectorial RP in the superior and inferotemporal sectors covering the macula in the same eye with figures. PMID:23781365
Noonan's syndrome with keratoconus and optic disc coloboma.
Ascaso, F J; Del Buey, M A; Huerva, V; Latre, B; Palomar, A
1993-01-01
We report the case of a 14-year-old girl with multiple findings characteristic of Noonan's syndrome, including short stature, mild mental retardation, facial, skeletal and renal abnormalities. In addition, ophthalmic examination revealed a keratoconus in the left eye and a right optic disc coloboma. To date, only two cases of Noonan's syndrome with keratoconus have been reported, and this is the second case of this syndrome with optic disc coloboma. To our knowledge, this is the first report of Noonan's syndrome associated with unilateral keratoconus and contralateral optic disc coloboma. In view of the large number of patients with Noonan's syndrome reported to date and the rarity of these ocular abnormalities, it is most likely that this association is fortuitous. Ocular findings reported in patients with Noonan's syndrome are reviewed.
Enders, Philip; Adler, Werner; Schaub, Friederike; Hermann, Manuel M; Dietlein, Thomas; Cursiefen, Claus; Heindl, Ludwig M
2016-12-01
The purpose of this study was to assess the diagnostic power of the novel two-dimensional parameter Bruch's membrane opening minimal rim area (BMO-MRA) in spectral-domain optical coherence tomography (SD-OCT) for detection of glaucoma compared to minimal rim width (BMO-MRW) and retinal nerve fiber layer (RNFL) thickness in large and small optic discs. In this case-control, cross-sectional study, 207 eyes of 207 participants, including 89 controls and 97 patients with glaucoma and 21 with ocular hypertension (OHT), with a disc size <1.63 mm2 or >2.43 mm2 underwent SD-OCT, confocal laser scanning tomography (CSLT), visual field testing, and clinical examination. Bruch's membrane opening-MRA BMO-MRW, RNFL thickness of SD-OCT and disc margin rim area (DM-RA) of CSLT were evaluated and analyzed for diagnostic power to detect glaucoma. In healthy eyes with macrodiscs, mean BMO-MRW of 243.14 ± 43.12 μm was significantly smaller than BMO-MRW in microdiscs (338.97 ± 69.39; P < 0.001). Bruch's membrane opening-MRA was comparable between disc size groups with 1.22 ± 0.25 mm2 for macrodiscs and 1.26 ± 0.27 mm2 for microdiscs (P = 0.51), as was RNFL thickness (82.69 ± 15.76 μm versus 78.53 ± 11.01 μm, respectively; P = 0.28). Perimetric mean deviation was -8.7 ± 6.3 dB in glaucoma and -0.6 ± 1.60 dB in OHT patients. Correlation of BMO-MRA and visual field function was rho (ρ) = 0.70 (P < 0.001). Diagnostic power to differentiate glaucoma patients was highest for BMO-MRA. Partial area under the curve (pAUC) for BMO-MRA was 0.14 for specificity between 0.8 and 1.0, exceeding pAUCs of BMO-MRW (P < 0.001), RNFL thickness (P = 0.03), and DM-RA (P = 0.01). Bruch's membrane opening-based minimum rim area measurements offer advantages compared to one-dimensional parameters assessing neuroretinal rim by SD-OCT. In nonglaucomatous eyes, BMO-MRA values seem comparable for the full range of disc sizes. Bruch's membrane opening-MRA surpasses other parameters in diagnostic power for glaucoma.
Disc origin of broad optical emission lines of the TDE candidate PTF09djl
NASA Astrophysics Data System (ADS)
Liu, F. K.; Zhou, Z. Q.; Cao, R.; Ho, L. C.; Komossa, S.
2017-11-01
An otherwise dormant supermassive black hole (SMBH) in a galactic nucleus flares up when it tidally disrupts a star passing by. Most of the tidal disruption events (TDEs) and candidates discovered in the optical/UV have broad optical emission lines with complex and diverse profiles of puzzling origin. In this Letter, we show that the double-peaked broad H α line of the TDE candidate PTF09djl can be well modelled with a relativistic elliptical accretion disc and the peculiar substructures with one peak at the line rest wavelength and the other redshifted to about 3.5 × 104 km s-1 are mainly due to the orbital motion of the emitting matter within the disc plane of large inclination 88° and pericentre orientation nearly vertical to the observer. The accretion disc has an extreme eccentricity 0.966 and semimajor axis of 340 BH Schwarzschild radii. The viewing angle effects of large disc inclination lead to significant attenuation of He emission lines originally produced at large electron scattering optical depth and to the absence/weakness of He emission lines in the spectra of PTF09djl. Our results suggest that the diversities of line intensity ratios among the line species in optical TDEs are probably due to the differences of disc inclinations.
A partial eclipse of the heart: the absorbed X-ray low state in Mrk 1048
NASA Astrophysics Data System (ADS)
Parker, M. L.; Schartel, N.; Komossa, S.; Grupe, D.; Santos-Lleó, M.; Fabian, A. C.; Mathur, S.
2014-11-01
We present two new XMM-Newton observations of an unprecedented low-flux state in the Seyfert 1 Mrk 1048 (NGC 985), taken in 2013. The X-ray flux below 1 keV drops by a factor of 4-5, whereas the spectrum above 5 keV is essentially unchanged. This points towards an absorption origin for the low state, and we confirm this with spectral fitting, finding that the spectral differences can be well modelled by the addition of a partial covering neutral absorber, with a column density of ˜3 × 1022 cm-2 and a covering fraction of ˜0.6. The optical and UV fluxes are not affected, and indeed are marginally brighter in the more recent observations, suggesting that only the inner regions of the disc are affected by the absorption event. This indicates either that the absorption is due to a cloud passing over the inner disc, obscuring the X-ray source but leaving the outer disc untouched, or that the absorber is dust-free so the UV continuum is unaffected. We use arguments based on the duration of the event and the physical properties of the absorber to constrain its size and location, and conclude that it is most likely a small cloud at ˜1018 cm from the source.
Biometry and spectral domain optical coherence tomography parameters in children with large cupping.
Jung, Jong Jin; Baek, Seung-Hee; Kim, Ungsoo Samuel
2013-09-01
The purpose of this study is to investigate optic nerve head using spectral domain optical coherence tomography (SD-OCT) in children with large cupping. 111 eyes (4-10 years) were divided into three groups according to the cup to disc ratio: group 1, ≤0.3; group 2, 0.4-0.6; and group 3, ≥0.7. The rim area, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume were investigated using SD-OCT (Cirrus HD-OCT, Carl Zeiss, Jena, Germany), and the axial length and anterior chamber depth (ACD) were measured by IOL master (IOL master 500, Carl Zeiss, Jena, Germany). Next, we compared ocular biometry and SD-OCT between the three groups. The mean age of group 1 was 6.48 ± 1.42 years, 7.00 ± 1.75 years in group 2, and 6.63 ± 1.82 years in group 3 (p = 0.370). A significant difference was seen in the spherical equivalent between the groups (p = 0.001). Group 2 had the most myopic refractive errors. As the cup to disc ratio increases, disc area, average cup to disc ratio, vertical cup to disc ratio, and cup volume increase significantly. When the results of ocular biometry and SD-OCT are adjusted for axial length, only disc area showed a significant correlation with cup to disc ratio (ACD: p = 0.473, rim area: p = 0.639, disc area: p = 0.005, and cup volume: p = 0.325). Axial length is the key factor determining disc size, which in turn is important for determining cup to disc ratio. Normal children with large cupping should be examined for axial length, myopic refractive errors, and disc size.
Mwanza, Jean-Claude; Huang, Linda Y; Budenz, Donald L; Shi, Wei; Huang, Gintien; Lee, Richard K
2017-12-01
To compare the vertical and horizontal cup-to-disc ratio (VCDR, HCDR) by an updated optical coherence tomography (OCT) Bruch membrane opening (BMO) algorithm and stereoscopic optic disc photograph readings by glaucoma specialists. Reliability analysis. A total of 195 eyes (116 glaucoma and 79 glaucoma suspect) of 99 patients with stereoscopic photographs and OCT scans of the optic discs taken during the same visit were compared. Optic disc photographs were read by 2 masked glaucoma specialists for VCDR and HCDR estimation. Intraclass correlation coefficient (ICC) and Bland-Altman plots were used to assess the agreement between photograph reading and OCT in estimating CDR. OCT images computed significantly larger VCDR and HCDR than photograph reading before and after stratifying eyes based on disc size (P < .001). The difference in CDR estimates between the 2 methods was equal to or greater than 0.2 in 29% and 35% of the eyes for VCDR and HCDR, respectively, with a mean difference of 0.3 in each case. The ICCs between the readers and OCT ranged between 0.50 and 0.63. The size of disagreement in VCDR correlated weakly with cup area in eyes with medium (r 2 = 0.10, P = .008) and large (r 2 = 0.09, P = .007) discs. OCT and photograph reading by clinicians agree poorly in CDR assessment. The difference in VCDR between the 2 methods was depended on cup area in medium and large discs. These differences should be considered when making conclusions regarding CDRs in clinical practice. Copyright © 2017 Elsevier Inc. All rights reserved.
Chai, Yuzhu; Yamamoto, Shuichi; Hirayama, Atsuko; Yotsukura, Jiro; Yamazaki, Hiroko
2005-01-01
To evaluate optic nerve function by pattern visual evoked potentials (VEPs) in eyes with optic disc swelling due to neuroretinitis associated with cat scratch disease (CSD). Four eyes of four patients with marked optic disc swelling resembling optic neuritis but diagnosed serologically as CSD received systemic steroid treatment. VEPs elicited by black and white checkerboard stimuli created on a TV monitor were recorded before the treatment. The visual acuity (VA) in the affected eyes was decreased to 20/50 in two eyes and finger counting in two eyes at their initial visits. Ophthalmoscopic examination revealed neuroretinitis characterized by severe optic disc swelling, chorioretinal exudates, and macular edema in all eyes. Anti-Bartonella henselae serum antibody was markedly elevated in all patients confirming the diagnosis of CSD. The P100 of the transient VEPs was only mildly reduced without a delay in the implicit times in three eyes and only slightly delayed in the other eye. The steady-state VEPs were mildly reduced in two eyes and phase-reversed in other two eyes. The VA fully recovered after systemic steroid treatment in all patients. Although all examined patients showed marked swelling of the optic disc and visual decrease, the pattern VEPs were not affected as severely as in idiopathic optic neuritis. However, the degree of change of the pattern VEPs varied among patients.
Interlayer Crosstalk Reduction by Controlling Backward Reflectivity in Multilayer Optical Discs
NASA Astrophysics Data System (ADS)
Ushiyama, Junko; Miyauchi, Yasushi; Shintani, Toshimichi; Sugiyama, Toshinori; Miyamoto, Harukazu; Kurokawa, Takahiro
2008-05-01
A method is proposed to reduce interlayer crosstalk in multilayer optical discs by controlling backward reflectivity of information layers, which can lead to wider tolerances of disc fabrication accuracy. Reduction of the backward reflectivity reduces the signal from the ghost spot even if thicknesses of spacer layers are equal. Experimental results showed that the ratio of the signals obtained by the readout spot and the ghost spot is less by about one order for a disc with controlled backward reflectivity than for a conventional disc. A rough estimate of the crosstalk caused by the ghost spot agrees qualitatively with the experimental results.
A new approach to optic disc detection in human retinal images using the firefly algorithm.
Rahebi, Javad; Hardalaç, Fırat
2016-03-01
There are various methods and algorithms to detect the optic discs in retinal images. In recent years, much attention has been given to the utilization of the intelligent algorithms. In this paper, we present a new automated method of optic disc detection in human retinal images using the firefly algorithm. The firefly intelligent algorithm is an emerging intelligent algorithm that was inspired by the social behavior of fireflies. The population in this algorithm includes the fireflies, each of which has a specific rate of lighting or fitness. In this method, the insects are compared two by two, and the less attractive insects can be observed to move toward the more attractive insects. Finally, one of the insects is selected as the most attractive, and this insect presents the optimum response to the problem in question. Here, we used the light intensity of the pixels of the retinal image pixels instead of firefly lightings. The movement of these insects due to local fluctuations produces different light intensity values in the images. Because the optic disc is the brightest area in the retinal images, all of the insects move toward brightest area and thus specify the location of the optic disc in the image. The results of implementation show that proposed algorithm could acquire an accuracy rate of 100 % in DRIVE dataset, 95 % in STARE dataset, and 94.38 % in DiaRetDB1 dataset. The results of implementation reveal high capability and accuracy of proposed algorithm in the detection of the optic disc from retinal images. Also, recorded required time for the detection of the optic disc in these images is 2.13 s for DRIVE dataset, 2.81 s for STARE dataset, and 3.52 s for DiaRetDB1 dataset accordingly. These time values are average value.
ERIC Educational Resources Information Center
International Federation of Library Associations and Institutions, The Hague (Netherlands).
Four papers on information technology were presented at the 1986 International Federation of Library Associations (IFLA) conference. In the paper "Optical Disc Technology Used for Large-Scale Data Base," Naoto Nakayama (Japan) considers the rapid development of optical technology and the role of applications such as optical discs,…
Micropulse laser for persistent optic disc pit maculopathy. A case report.
Valdés-Lara, Carlos Andrés; Crim, Nicolás; García-Aguirre, Gerardo; Lule, Ismael Ávila; Morales-Cantón, Virgilio
2018-06-01
Optic disc pits (ODP) are rare and congenital anomalies of the optic disc, sometimes remaining asymptomatic. However, serous macular detachment or optic disc maculopathy is the most common complication, causing significant visual deterioration, without a current consensus about treatment. We describe a case of ODP maculopathy that was treated successfully with micropulse laser. A patient with ODP maculopathy remained with macular serous detachment after nine months of follow up after pars plana vitrectomy. Subthreshold micropulse laser was used to treat macular serous detachment, achieving a significant improvement in central macular thickness after one session. Subthreshold micropulse laser is designed to stimulate the retinal pigment epithelium without damage to the photoreceptors, resulting in absorption of subretinal and intraretinal fluid. Macular serous detachment in patients with ODP requires a prompt diagnosis and treatment to avoid damage to photoreceptors. Subthreshold micropulse laser is a potential treatment for eyes with ODP and macular serous detachment complication.
Ultra Compact Optical Pickup with Integrated Optical System
NASA Astrophysics Data System (ADS)
Nakata, Hideki; Nagata, Takayuki; Tomita, Hironori
2006-08-01
Smaller and thinner optical pickups are needed for portable audio-visual (AV) products and notebook personal computers (PCs). We have newly developed an ultra compact recordable optical pickup for Mini Disc (MD) that measures less than 4 mm from the disc surface to the bottom of the optical pickup, making the optical system markedly compact. We have integrated all the optical components into an objective lens actuator moving unit, while fully satisfying recording and playback performance requirements. In this paper, we propose an ultra compact optical pickup applicable to portable MD recorders.
Wang, Mingwu; Lu, Ake Tzu-Hui; Varma, Rohit; Schuman, Joel S; Greenfield, David S; Huang, David
2014-03-01
To improve the diagnosis of glaucoma by combining time-domain optical coherence tomography (TD-OCT) measurements of the optic disc, circumpapillary retinal nerve fiber layer (RNFL), and macular retinal thickness. Ninety-six age-matched normal and 96 perimetric glaucoma participants were included in this observational, cross-sectional study. Or-logic, support vector machine, relevance vector machine, and linear discrimination function were used to analyze the performances of combined TD-OCT diagnostic variables. The area under the receiver-operating curve (AROC) was used to evaluate the diagnostic accuracy and to compare the diagnostic performance of single and combined anatomic variables. The best RNFL thickness variables were the inferior (AROC=0.900), overall (AROC=0.892), and superior quadrants (AROC=0.850). The best optic disc variables were horizontal integrated rim width (AROC=0.909), vertical integrated rim area (AROC=0.908), and cup/disc vertical ratio (AROC=0.890). All macular retinal thickness variables had AROCs of 0.829 or less. Combining the top 3 RNFL and optic disc variables in optimizing glaucoma diagnosis, support vector machine had the highest AROC, 0.954, followed by or-logic (AROC=0.946), linear discrimination function (AROC=0.946), and relevance vector machine (AROC=0.943). All combination diagnostic variables had significantly larger AROCs than any single diagnostic variable. There are no significant differences among the combination diagnostic indices. With TD-OCT, RNFL and optic disc variables had better diagnostic accuracy than macular retinal variables. Combining top RNFL and optic disc variables significantly improved diagnostic performance. Clinically, or-logic classification was the most practical analytical tool with sufficient accuracy to diagnose early glaucoma.
NASA Astrophysics Data System (ADS)
Wang, Mengyu; Wang, Hui; Baniasadi, Neda; Elze, Tobias
2017-02-01
Purpose: Optic disc tilt defined over 3D optic disc morphology has been shown to be associated with the location of initial glaucomatous damages. In this work, we study the impact of optic cup depth (OCD) on spatial patterns of visual field loss in glaucoma. Methods: Pairs of reliable Cirrus OCT scans around optic disc and Humphrey visual fields of glaucoma patients without visually significant cataract and age-related macular degeneration were selected. The most recent visit of a randomly selected eye of each patient was chosen. The OCD was automatically calculated on the superior-inferior cross sectional image passing through the optic disc center. The correlations between the mean pattern deviation (PD) of each sector in glaucoma hemifield test (GHT) and Garway-Heath scheme and OCD were evaluated for all severities glaucoma and mild glaucoma (mean deviation >= -5 dB), respectively. Results: 424 eyes of 424 patients passed the data reliability criteria with 346 mild glaucoma patients. For all severities glaucoma, there was no significant correlation between the mean sector PD and OCD. For mild glaucoma, OCD was uniquely correlated to the mean PD of the inferior pericentral sector (r=-0.18, p=0.01) in GHT, which was independent of mean deviation and retinal nerve fiber layer thickness (p<0.001 for both). Conclusion: OCD was uniquely correlated to the vision loss of the inferior pericentral sector in GHT and Garway- Health scheme for mild glaucoma. Future advancement of OCT imaging techniques may provide better clinical diagnosis for early glaucoma by focusing on 3D morphological variation of the optic disc.
Review of ultra-high density optical storage technologies for big data center
NASA Astrophysics Data System (ADS)
Hao, Ruan; Liu, Jie
2016-10-01
In big data center, optical storage technologies have many advantages, such as energy saving and long lifetime. However, how to improve the storage density of optical storage is still a huge challenge. Maybe the multilayer optical storage technology is the good candidate for big data center in the years to come. Due to the number of layers is primarily limited by transmission of each layer, the largest capacities of the multilayer disc are around 1 TB/disc and 10 TB/ cartridge. Holographic data storage (HDS) is a volumetric approach, but its storage capacity is also strictly limited by the diffractive nature of light. For a holographic disc with total thickness of 1.5mm, its potential capacities are not more than 4TB/disc and 40TB/ cartridge. In recent years, the development of super resolution optical storage technology has attracted more attentions. Super-resolution photoinduction-inhibition nanolithography (SPIN) technology with 9 nm feature size and 52nm two-line resolution was reported 3 years ago. However, turning this exciting principle into a real storage system is a huge challenge. It can be expected that in the future, the capacities of 10TB/disc and 100TB/cartridge can be achieved. More importantly, due to breaking the diffraction limit of light, SPIN technology will open the door to improve the optical storage capacity steadily to meet the need of the developing big data center.
Toxocara optic neuropathy: clinical features and ocular findings.
Choi, Kwang-Dong; Choi, Jae-Hwan; Choi, Seo-Young; Jung, Jae Ho
2018-01-01
We evaluated thirteen eyes of twelve patients diagnosed clinically and serologically with Toxocara optic neuropathy. Eleven patients had unilateral involvement and one patient had bilateral optic neuropathy. Eight patients (66.7%) had a possible infection source to Toxocara. Six patients (50%) had painless acute optic neuropathy. Ten eyes had asymmetric, sectorial optic disc edema with peripapillary infiltration and three eyes had diffuse optic disc edema. Eosinophilia was noted in five patients (41.7%) and optic nerve enhancement was observed in eight of eleven eyes (72.7%) with available orbit magnetic resonance imaging (MRI). Mean visual acuity significantly improved following treatment [mean logarithmic of the minimum angle of resolution (logMAR) 0.94±0.56 at baseline and 0.47±0.59 at the final ( P =0.02)]. Asymmetric optic disc edema with a peripapillary lesion and a history of raw meat ingestion were important clues for diagnosing Toxocara optic neuropathy. Additionally, Toxocara IgG enzyme-linked immunosorbent assay (ELISA) test and evaluating eosinophil may be helpful for diagnosis.
Toxocara optic neuropathy: clinical features and ocular findings
Choi, Kwang-Dong; Choi, Jae-Hwan; Choi, Seo-Young; Jung, Jae Ho
2018-01-01
We evaluated thirteen eyes of twelve patients diagnosed clinically and serologically with Toxocara optic neuropathy. Eleven patients had unilateral involvement and one patient had bilateral optic neuropathy. Eight patients (66.7%) had a possible infection source to Toxocara. Six patients (50%) had painless acute optic neuropathy. Ten eyes had asymmetric, sectorial optic disc edema with peripapillary infiltration and three eyes had diffuse optic disc edema. Eosinophilia was noted in five patients (41.7%) and optic nerve enhancement was observed in eight of eleven eyes (72.7%) with available orbit magnetic resonance imaging (MRI). Mean visual acuity significantly improved following treatment [mean logarithmic of the minimum angle of resolution (logMAR) 0.94±0.56 at baseline and 0.47±0.59 at the final (P=0.02)]. Asymmetric optic disc edema with a peripapillary lesion and a history of raw meat ingestion were important clues for diagnosing Toxocara optic neuropathy. Additionally, Toxocara IgG enzyme-linked immunosorbent assay (ELISA) test and evaluating eosinophil may be helpful for diagnosis. PMID:29600190
Drosophila Lyra mutations are gain-of-function mutations of senseless
NASA Technical Reports Server (NTRS)
Nolo, R.; Abbott, L. A.; Bellen, H. J.
2001-01-01
The Lyra mutation was first described by Jerry Coyne in 1935. Lyra causes recessive pupal lethality and adult heterozygous Lyra mutants exhibit a dominant loss of the anterior and posterior wing margins. Unlike many mutations that cause loss of wing tissue (e.g., scalloped, Beadex, cut, and apterous-Xasta), Lyra wing discs do not exhibit increased necrotic or apoptotic cell death, nor do they show altered BrdU incorporation. However, during wing disc eversion, loss of the anterior and posterior wing margins is apparent. We have previously shown that senseless, a gene that is necessary and sufficient for peripheral nervous system (PNS) development, is allelic to Lyra. Here we show by several genetic criteria that Lyra alleles are neomorphic alleles of senseless that cause ectopic expression of SENSELESS in the wing pouch. Similarly, overexpression of SENSELESS in the wing disc causes loss of wing margin tissue, thereby mimicking the Lyra phenotype. Lyra mutants display aberrant expression of DELTA, VESTIGIAL, WINGLESS, and CUT. As in Lyra mutants, overexpression of SENSELESS in some areas of the wing pouch also leads to loss of WINGLESS and CUT. In summary, our data indicate that overexpression of SENSELESS causes a severe reduction in NOTCH signaling that in turn may lead to decreased transcription of several key genes required for wing development, leading to a failure in cell proliferation and loss of wing margin tissue.
The absence of a thin disc in M81*
NASA Astrophysics Data System (ADS)
Young, A. J.; McHardy, I.; Emmanoulopoulos, D.; Connolly, S.
2018-06-01
We present the results of simultaneous Suzaku and NuSTAR observations of the nearest low-luminosity active galactic nucleus (LLAGN), M81*. The spectrum is well described by a cut-off power law plus narrow emission lines from Fe K α, Fe xxv, and Fe xxvi. There is no evidence of Compton reflection from an optically thick disc, and we obtain the strongest constraint on the reflection fraction in M81* to date, with a best-fitting value of R = 0.0 with an upper limit of R < 0.1. The Fe K α line may be produced in optically thin, N_H = 1 × 10^{23} cm^{-2}, gas located in the equatorial plane that could be the broad line region. The ionized iron lines may originate in the hot, inner accretion flow. The X-ray continuum shows significant variability on ˜40 ks time-scales suggesting that the primary X-ray source is ˜100 s of gravitational radii in size. If this X-ray source illuminates any putative optically thick disc, the weakness of reflection implies that such a disc lies outside a few ×103 gravitational radii. An optically thin accretion flow inside a truncated optically thick disc appears to be a common feature of LLAGN that are accreting at only a tiny fraction of the Eddington limit.
Medical Information on Optical Disc*
Schipma, Peter B.; Cichocki, Edward M.; Ziemer, Susan M.
1987-01-01
Optical discs may permit a revolutionary change in the distribution and use of medical information. A single compact disc, similar in size to that used for digital audio recording, can contain over 500 million characters of information that is accessible by a Personal Computer. These discs can be manufactured at a cost lower than that of print on paper, at reasonable volumes. Software can provide the health care professional with nearly instantaneous access to the information. Thus, for the first time, the opportunity exists to have large local medical information collections. This paper describes an application of this technology in the field of Oncology.
Automated analysis of heidelberg retina tomograph optic disc images by glaucoma probability score.
Coops, Annemiek; Henson, David Barry; Kwartz, Anna J; Artes, Paul Habib
2006-12-01
To compare the diagnostic performance of the Heidelberg Retinal Tomograph's (HRT; Heidelberg Engineering GmbH, Dossenheim, Germany) glaucoma probability score (GPS), an automated, contour line-independent method of optic disc analysis with that of the Moorfields regression analysis (MRA). HRT images were obtained from one eye of 121 patients with glaucoma (median age, 70.2 years; median mean deviation [MD], -3.6 dB, range, +2.0 to -9.9 dB) and 95 healthy control subjects (median age, 59.7 years; median MD -0.1 dB, range +2.5 to -3.7). The diagnostic performances of GPS and MRA were evaluated by including borderline classifications, either as test negatives (most specific criteria) or as test positives (least specific criteria). Agreement between global and sectoral data of both analyses was established. Logistic regression analyses were performed to evaluate the effect of covariates such as optic disc size and age on the classification outcomes of both the GPS and the MRA. In 8 (7%) patients with glaucoma and 10 (11%) control subjects, the GPS failed to provide a complete global and sectoral optic disc classification. Although we could not identify a single distinct cause of this failure in the glaucoma group, failures in the control subjects occurred most often (7/10) with small and crowded optic discs. In subjects who were successfully classified at least globally by the GPS (117 patients with glaucoma, 88 control subjects), the diagnostic performances of GPS and MRA were similar (areas under the receiver operating characteristic [ROC] curve of 0.78 and 0.77, respectively; P > 0.1). With the GPS, sensitivity and specificity were 59% and 91% (most specific criteria) and 78% and 63% (least specific criteria), respectively. Combining GPS and MRA did not increase diagnostic performance significantly (ROC area of combined classifiers, 0.81). Both GPS and MRA were affected by disc size. In patients with glaucoma as well as healthy control subjects, the odds of a positive GPS classification (borderline or outside normal limits) increased by 21% (95% confidence interval [CI], 12%-30%) for each 0.1 mm2 increase in optic disc area. With the MRA, the corresponding increase was 15% (95% CI, 7%-23%). Optic disc area alone accounted for approximately 30% and 22% of the explained variance with the GPS and MRA, respectively (P < 0.001). The proportional-odds logistic regression confirmed that optic disc size affected mainly the tradeoff between true- and false-positive classifications (criterion) rather than the absolute performance of the analyses (area under the ROC curve). There was some evidence of an age effect with the MRA, which showed a 53% (95% CI, 16%-102%) increase in the odds of a positive test (borderline or outside normal limits) associated with each decade of age (P = 0.002), but no age effects were observed with the GPS (P > 0.1). The diagnostic performance of the contour line-independent GPS analysis is similar to that of the MRA. However, clinicians should be aware of the strong size dependence of both GPS and MRA. In large optic discs, both GPS and MRA are likely to produce many false-positive classifications. Correspondingly, the sensitivity to early damage is likely to be low in small optic discs. There is a need for automated classification systems that explicitly address the size dependence of current analyses.
Stereochronoscopy of the optic disc with stereoscopic cameras.
Schirmer, K E; Kratky, V
1980-09-01
Goldmann's chronoscopy, a form of time-based photogrammetry of the optic disc, can be accomplished by repeated simultaneous stereophotography. The variations in centration and image orientation are nulled by azimuthal rotation and fusion of two pairs of stereophotographs taken at separate times.
Cunha, Leonardo Provetti; Cunha, Luciana Virgínia Ferreira Costa; Costa, Carolina Ferreira; Monteiro, Mário Luiz Ribeiro
2016-01-01
Herein, we report a case of nonarteritic anterior ischemic optic neuropathy (NAION) following uneventful pars plana vitrectomy for macular hole treatment. A 56-year-old previously healthy woman presented with a full-thickness macular hole in right eye (OD) and small cup-to-disc ratios in both eyes. Five days after surgery, she noticed sudden painless loss of vision in OD and was found to have an afferent pupillary defect and intraocular pressure of 29 mmHg. Fundus examination showed right optic disc edema and the resolution of a macular hole with an inferior altitudinal visual field defect. Erythrocyte sedimentation rate, C-reactive protein levels, and general physical examination findings were normal. She was treated with hypotensive eyedrops and oral prednisone, resulting in mild visual improvement and a pale optic disc. A combination of face-down position and increased intraocular pressure due to a small optic disc cup were considered as potential mechanisms underlying NAION in the present case. Vitreoretinal surgeons should be aware of NAION as a potentially serious complication and be able to recognize associated risk factors and clinical findings.
Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook
2016-01-01
To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size.
Huang, Jehn-Yu; Pekmezci, Melike; Mesiwala, Nisreen; Kao, Andrew; Lin, Shan
2011-02-01
To evaluate the capability of the optic disc, peripapillary retinal nerve fiber layer (P-RNFL), macular inner retinal layer (M-IRL) parameters, and their combination obtained by Fourier-domain optical coherent tomography (OCT) in differentiating a glaucoma suspect from perimetric glaucoma. Two hundred and twenty eyes from 220 patients were enrolled in this study. The optic disc morphology, P-RNFL, and M-IRL were assessed by the Fourier-domain OCT (RTVue OCT, Model RT100, Optovue, Fremont, CA). A linear discriminant function was generated by stepwise linear discriminant analysis on the basis of OCT parameters and demographic factors. The diagnostic power of these parameters was evaluated with receiver operating characteristic (ROC) curve analysis. The diagnostic power in the clinically relevant range (specificity ≥ 80%) was presented as the partial area under the ROC curve (partial AROC). The individual OCT parameter with the largest AROC and partial AROC in the high specificity (≥ 80%) range were cup/disc vertical ratio (AROC = 0.854 and partial AROC = 0.142) for the optic disc parameters, average thickness (AROC = 0.919 and partial AROC = 0.147) for P-RNFL parameters, inferior hemisphere thickness (AROC = 0.871 and partial AROC = 0.138) for M-IRL parameters, respectively. The linear discriminant function further enhanced the ability in detecting perimetric glaucoma (AROC = 0.970 and partial AROC = 0.172). Average P-RNFL thickness is the optimal individual OCT parameter to detect perimetric glaucoma. Simultaneous evaluation on disc morphology, P-RNFL, and M-IRL thickness can improve the diagnostic accuracy in diagnosing glaucoma.
Optic disc, foveal, and extrafoveal damage due to surgical separation of the vitreous.
Russell, S R; Hageman, G S
2001-11-01
To evaluate the morphologic outcomes resulting from surgical vitreoretinal separation in young adult primates. Vitrectomy and mechanical separation of the vitreous from the internal limiting lamina (ILL) of the posterior retina and surface of the optic disc were performed on 25 young adult cynomolgus monkey eyes in vivo. Lectin histochemical studies were used to evaluate the vitreoretinal interface. Morphologic outcomes were tabulated. In 11 of 25 eye regions, residual vitreous remained attached to the ILL in some of the regions. Localized ILL breaks or separation of the ILL from the neural retina was noted in 9 eyes. Retinal tissue loss, including avulsion of the ganglion cell, inner plexiform, or inner nuclear layers, was observed in 7 eyes. Avulsion of axon bundles in the optic disc was noted in 9 eyes. Significantly, partial- or full-thickness foveal tears were noted in 11 eyes. Based on the surgeons' intraoperative observations, small superficial optic disc or retinal hemorrhages were observed in 3 of 25 eyes. None of the eyes on which a vitrectomy alone was performed showed ILL damage, or retinal or optic disc tissue loss. Damage may occur to the optic disc, fovea, and extrafoveal retina as a result of surgical separation of the vitreous from the retina in young adult primates. These data support the contention that surgically induced damage at the level of the vitreoretinal interface may help explain the visual field defects noted after surgery to close full-thickness macular holes. These data also support the need for developing additional modalities to assist in vitreous separation, thereby reducing the risk of traumatic complications associated with purely mechanical procedures.
Joint optic disc and cup boundary extraction from monocular fundus images.
Chakravarty, Arunava; Sivaswamy, Jayanthi
2017-08-01
Accurate segmentation of optic disc and cup from monocular color fundus images plays a significant role in the screening and diagnosis of glaucoma. Though optic cup is characterized by the drop in depth from the disc boundary, most existing methods segment the two structures separately and rely only on color and vessel kink based cues due to the lack of explicit depth information in color fundus images. We propose a novel boundary-based Conditional Random Field formulation that extracts both the optic disc and cup boundaries in a single optimization step. In addition to the color gradients, the proposed method explicitly models the depth which is estimated from the fundus image itself using a coupled, sparse dictionary trained on a set of image-depth map (derived from Optical Coherence Tomography) pairs. The estimated depth achieved a correlation coefficient of 0.80 with respect to the ground truth. The proposed segmentation method outperformed several state-of-the-art methods on five public datasets. The average dice coefficient was in the range of 0.87-0.97 for disc segmentation across three datasets and 0.83 for cup segmentation on the DRISHTI-GS1 test set. The method achieved a good glaucoma classification performance with an average AUC of 0.85 for five fold cross-validation on RIM-ONE v2. We propose a method to jointly segment the optic disc and cup boundaries by modeling the drop in depth between the two structures. Since our method requires a single fundus image per eye during testing it can be employed in the large-scale screening of glaucoma where expensive 3D imaging is unavailable. Copyright © 2017 Elsevier B.V. All rights reserved.
Discus: investigating subjective judgment of optic disc damage.
Denniss, Jonathan; Echendu, Damian; Henson, David B; Artes, Paul H
2011-01-01
To describe a software package (Discus) for investigating clinicians' subjective assessment of optic disc damage [diagnostic accuracy in detecting visual field (VF) damage, decision criteria, and agreement with a panel of experts] and to provide reference data from a group of expert observers. Optic disc images were selected from patients with manifest or suspected glaucoma or ocular hypertension who attended the Manchester Royal Eye Hospital. Eighty images came from eyes without evidence of VF loss in at least four consecutive tests (VF negatives), and 20 images from eyes with repeatable VF loss (VF positives). Software was written to display these images in randomized order, for up to 60 s. Expert observers (n = 12) rated optic disc damage on a 5-point scale (definitely healthy, probably healthy, not sure, probably damaged, and definitely damaged). Optic disc damage as determined by the expert observers predicted VF loss with less than perfect accuracy (mean area under receiver-operating characteristic curve, 0.78; range, 0.72 to 0.85). When the responses were combined across the panel of experts, the area under receiver-operating characteristic curve reached 0.87, corresponding to a sensitivity of ∼60% at 90% specificity. Although the observers' performances were similar, there were large differences between the criteria they adopted (p < 0.001), even though all observers had been given identical instructions. Discus provides a simple and rapid means for assessing important aspects of optic disc interpretation. The data from the panel of expert observers provide a reference against which students, trainees, and clinicians may compare themselves. The program and the analyses described in this article are freely accessible from http://www.discusproject.blogspot.com/.
Automatic detection of retinal anatomy to assist diabetic retinopathy screening.
Fleming, Alan D; Goatman, Keith A; Philip, Sam; Olson, John A; Sharp, Peter F
2007-01-21
Screening programmes for diabetic retinopathy are being introduced in the United Kingdom and elsewhere. These require large numbers of retinal images to be manually graded for the presence of disease. Automation of image grading would have a number of benefits. However, an important prerequisite for automation is the accurate location of the main anatomical features in the image, notably the optic disc and the fovea. The locations of these features are necessary so that lesion significance, image field of view and image clarity can be assessed. This paper describes methods for the robust location of the optic disc and fovea. The elliptical form of the major retinal blood vessels is used to obtain approximate locations, which are refined based on the circular edge of the optic disc and the local darkening at the fovea. The methods have been tested on 1056 sequential images from a retinal screening programme. Positional accuracy was better than 0.5 of a disc diameter in 98.4% of cases for optic disc location, and in 96.5% of cases for fovea location. The methods are sufficiently accurate to form an important and effective component of an automated image grading system for diabetic retinopathy screening.
Automatic detection of retinal anatomy to assist diabetic retinopathy screening
NASA Astrophysics Data System (ADS)
Fleming, Alan D.; Goatman, Keith A.; Philip, Sam; Olson, John A.; Sharp, Peter F.
2007-01-01
Screening programmes for diabetic retinopathy are being introduced in the United Kingdom and elsewhere. These require large numbers of retinal images to be manually graded for the presence of disease. Automation of image grading would have a number of benefits. However, an important prerequisite for automation is the accurate location of the main anatomical features in the image, notably the optic disc and the fovea. The locations of these features are necessary so that lesion significance, image field of view and image clarity can be assessed. This paper describes methods for the robust location of the optic disc and fovea. The elliptical form of the major retinal blood vessels is used to obtain approximate locations, which are refined based on the circular edge of the optic disc and the local darkening at the fovea. The methods have been tested on 1056 sequential images from a retinal screening programme. Positional accuracy was better than 0.5 of a disc diameter in 98.4% of cases for optic disc location, and in 96.5% of cases for fovea location. The methods are sufficiently accurate to form an important and effective component of an automated image grading system for diabetic retinopathy screening.
Long term multiwavelength studies of the corona/disc connection in AGN
NASA Astrophysics Data System (ADS)
Buisson, D.; Lohfink, A.; Alston, W.; Fabian, A.; Gallo, L.; Kara, E.; Zoghbi, A.; Wilkins, D.; Miller, J.; Cackett, E.
2017-10-01
One way of increasing our understanding of AGN is determining the nature of the connection between the optical/UV emitting accretion disc and the X-ray emitting corona. Studies of variability in these two bands are a key tool for gaining insight into the processes involved. We will present results from a sample of long-term AGN monitoring campaigns in the optical, UV and X-ray with Swift. In particular, we will explore UV/optical-X-ray correlations and associated time lags. We will compare these measurements and the UV/optical RMS spectra with theoretical reprocessing models and confront recent claims of the observed lags being longer than those which are expected for a standard thin disc. Additionally, a new Swift monitoring campaign of the z=2 quasar PG 1247+267 allows us to probe the shorter wavelengths at the peak of the accretion disc spectrum, providing information on the region of the disc closest to the black hole. However, not all AGN show such correlations, including IRAS 13224-3809, the subject of a recent 1.5 Ms XMM observation. Using this and other examples, we will explore the possible reasons for the lack of observed correlation.
The local stability of the magnetized advection-dominated discs with the radial viscous force
NASA Astrophysics Data System (ADS)
Ghoreyshi, S. M.; Shadmehri, M.
2018-06-01
We study local stability of the advection-dominated optically thick (slim) and optically thin discs with purely toroidal magnetic field and the radial viscous force using a linear perturbation analysis. Our dispersion relation indicates that the presence of magnetic fields and radial viscous force cannot give rise to any new mode of the instability. We find, however, that growth rate of the thermal mode in the slim discs and that of the acoustic modes in the slim and optically thin discs are dramatically affected by the radial viscous force. This force tends to strongly decrease the growth rate of the outward-propagating acoustic mode (O-mode) in the short-wavelength limit, but it causes a slim disc to become thermally more unstable. This means that growth rate of the thermal mode increases in the presence of radial viscous force. This enhancement is more significant when the viscosity parameter is large. The growth rates of the thermal and acoustic modes depend on the magnetic field. Although the instability of O-mode for a stronger magnetic field case has a higher growth rate, the thermal mode of the slim discs can be suppressed when the magnetic field is strong. The inertial-acoustic instability of a magnetized disc may explain the quasi-periodic oscillations (QPOs) from the black holes.
Akiyama, Hideo; Li, Danjie; Shimoda, Yukitoshi; Matsumoto, Hidetaka; Kishi, Shoji
2018-05-01
To describe the relationship between the vitreous and the neovascularization of the disc (NVD) using swept source optical coherence tomography (SS-OCT) and OCT angiography (OCTA). Retrospective. We examined 17 eyes of 11 consecutive patients diagnosed as NVD associated with proliferative diabetic retinopathy (PDR). The location of the NVD feeder or collector vessels were examined by using RTVue XR Avanti. To determine the condition of the posterior vitreous detachment (PVD) and the proliferative tissue of the NVD, we performed 12 mm horizontal and vertical scans through the disc using SS-OCT. OCT images of all 17 cases indicated there was no PVD on the optic disc. OCTA showed that the locations of the newly formed vessels from the optic disc were overwhelmingly outside the physiological cupping (95%). No cases exhibited formation of neovascularization inside the physiological cupping. OCT images revealed all 17 eyes had proliferative tissues located under the posterior wall of the vitreous, with 12 out of 17 eyes exhibiting additional invasion of the proliferative tissue into the vitreous through the posterior wall. Epiretinal membrane or a thickened posterior wall of the vitreous was present in 10 out of the 17 eyes. NVD associated with PDR arises from outside the physiological cupping and grows along the posterior wall of the vitreous. The absence of PVD on the optic disc is essential to the growth of NVD.
Accretion Discs Around Black Holes: Developement of Theory
NASA Astrophysics Data System (ADS)
Bisnovatyi-Kogan, G. S.
Standard accretion disk theory is formulated which is based on the local heat balance. The energy produced by a turbulent viscous heating is supposed to be emitted to the sides of the disc. Sources of turbulence in the accretion disc are connected with nonlinear hydrodynamic instability, convection, and magnetic field. In standard theory there are two branches of solution, optically thick, and optically thin. Advection in accretion disks is described by the differential equations what makes the theory nonlocal. Low-luminous optically thin accretion disc model with advection at some suggestions may become advectively dominated, carrying almost all the energy inside the black hole. The proper account of magnetic filed in the process of accretion limits the energy advected into a black hole, efficiency of accretion should exceed ˜ 1/4 of the standard accretion disk model efficiency.
Wostyn, Peter; De Deyn, Peter Paul
2017-11-01
A significant proportion of the astronauts who spend extended periods in microgravity develop ophthalmic abnormalities. Understanding this syndrome, called visual impairment and intracranial pressure (VIIP), has become a high priority for National Aeronautics and Space Administration, especially in view of future long-duration missions (e.g., Mars missions). Moreover, to ensure selection of astronaut candidates who will be able to complete long-duration missions with low risk of the VIIP syndrome, it is imperative to identify biomarkers for VIIP risk prediction. Here, we hypothesize that the optic nerve sheath response to alterations in intracranial pressure may be a potential predictive biomarker for optic disc edema in astronauts. If confirmed, this biomarker could be used for preflight identification of astronauts at risk for developing VIIP-associated optic disc edema.
Springelkamp, Henriët; Iglesias, Adriana I.; Mishra, Aniket; Höhn, René; Wojciechowski, Robert; Khawaja, Anthony P.; Nag, Abhishek; Wang, Ya Xing; Wang, Jie Jin; Cuellar-Partida, Gabriel; Gibson, Jane; Bailey, Jessica N. Cooke; Vithana, Eranga N.; Gharahkhani, Puya; Boutin, Thibaud; Ramdas, Wishal D.; Zeller, Tanja; Luben, Robert N.; Yonova-Doing, Ekaterina; Viswanathan, Ananth C.; Yazar, Seyhan; Cree, Angela J.; Haines, Jonathan L.; Koh, Jia Yu; Souzeau, Emmanuelle; Wilson, James F.; Amin, Najaf; Müller, Christian; Venturini, Cristina; Kearns, Lisa S.; Kang, Jae Hee; Tham, Yih Chung; Zhou, Tiger; van Leeuwen, Elisabeth M.; Nickels, Stefan; Sanfilippo, Paul; Liao, Jiemin; van der Linde, Herma; Zhao, Wanting; van Koolwijk, Leonieke M.E.; Zheng, Li; Rivadeneira, Fernando; Baskaran, Mani; van der Lee, Sven J.; Perera, Shamira; de Jong, Paulus T.V.M.; Oostra, Ben A.; Uitterlinden, André G.; Fan, Qiao; Hofman, Albert; Tai, E-Shyong; Vingerling, Johannes R.; Sim, Xueling; Wolfs, Roger C.W.; Teo, Yik Ying; Lemij, Hans G.; Khor, Chiea Chuen; Willemsen, Rob; Lackner, Karl J.; Aung, Tin; Jansonius, Nomdo M.; Montgomery, Grant; Wild, Philipp S.; Young, Terri L.; Burdon, Kathryn P.; Hysi, Pirro G.; Pasquale, Louis R.; Wong, Tien Yin; Klaver, Caroline C.W.; Hewitt, Alex W.; Jonas, Jost B.; Mitchell, Paul; Lotery, Andrew J.; Foster, Paul J.; Vitart, Veronique; Pfeiffer, Norbert; Craig, Jamie E.; Mackey, David A.; Hammond, Christopher J.; Wiggs, Janey L.; Cheng, Ching-Yu; van Duijn, Cornelia M.; MacGregor, Stuart
2017-01-01
Abstract Primary open-angle glaucoma (POAG), the most common optic neuropathy, is a heritable disease. Siblings of POAG cases have a ten-fold increased risk of developing the disease. Intraocular pressure (IOP) and optic nerve head characteristics are used clinically to predict POAG risk. We conducted a genome-wide association meta-analysis of IOP and optic disc parameters and validated our findings in multiple sets of POAG cases and controls. Using imputation to the 1000 genomes (1000G) reference set, we identified 9 new genomic regions associated with vertical cup-disc ratio (VCDR) and 1 new region associated with IOP. Additionally, we found 5 novel loci for optic nerve cup area and 6 for disc area. Previously it was assumed that genetic variation influenced POAG either through IOP or via changes to the optic nerve head; here we present evidence that some genomic regions affect both IOP and the disc parameters. We characterized the effect of the novel loci through pathway analysis and found that pathways involved are not entirely distinct as assumed so far. Further, we identified a novel association between CDKN1A and POAG. Using a zebrafish model we show that six6b (associated with POAG and optic nerve head variation) alters the expression of cdkn1a. In summary, we have identified several novel genes influencing the major clinical risk predictors of POAG and showed that genetic variation in CDKN1A is important in POAG risk. PMID:28073927
Rao, Harsha L; Yadav, Ravi K; Addepalli, Uday K; Begum, Viquar U; Senthil, Sirisha; Choudhari, Nikhil S; Garudadri, Chandra S
2015-08-01
To evaluate the relationship between the reference standard used to diagnose glaucoma and the diagnostic ability of spectral domain optical coherence tomograph (SDOCT). In a cross-sectional study, 280 eyes of 175 consecutive subjects, referred to a tertiary eye care center for glaucoma evaluation, underwent optic disc photography, visual field (VF) examination, and SDOCT examination. The cohort was divided into glaucoma and control groups based on 3 reference standards for glaucoma diagnosis: first based on the optic disc classification (179 glaucoma and 101 control eyes), second on VF classification (glaucoma hemifield test outside normal limits and pattern SD with P-value of <5%, 130 glaucoma and 150 control eyes), and third on the presence of both glaucomatous optic disc and glaucomatous VF (125 glaucoma and 155 control eyes). Relationship between the reference standards and the diagnostic parameters of SDOCT were evaluated using areas under the receiver operating characteristic curve, sensitivity, and specificity. Areas under the receiver operating characteristic curve and sensitivities of most of the SDOCT parameters obtained with the 3 reference standards (ranging from 0.74 to 0.88 and 72% to 88%, respectively) were comparable (P>0.05). However, specificities of SDOCT parameters were significantly greater (P<0.05) with optic disc classification as reference standard (74% to 88%) compared with VF classification as reference standard (57% to 74%). Diagnostic parameters of SDOCT that was significantly affected by reference standard was the specificity, which was greater with optic disc classification as the reference standard. This has to be considered when comparing the diagnostic ability of SDOCT across studies.
Nakano, Eri; Hata, Masayuki; Oishi, Akio; Miyamoto, Kazuaki; Uji, Akihito; Fujimoto, Masahiro; Miyata, Manabu; Yoshimura, Nagahisa
2016-08-01
The purpose was to investigate an objective and quantitative method to estimate the redness of the optic disc neuroretinal rim, and to determine the usefulness of this method to differentiate compressive optic neuropathy (CON) from glaucomatous optic neuropathy (GON). In our study there were 126 eyes: 40 with CON, 40 with normal tension glaucoma (NTG), and 46 normal eyes (NOR). Digital color fundus photographs were assessed for the redness of disc rim color using ImageJ software. We separately measured the intensity of red, green, and blue pixels from RGB images. Three disc color indices (DCIs), which indicate the redness intensity, were calculated through existing formulas. All three DCIs of CON were significantly smaller than those of NOR (P < 0.001). In addition, when compared with NTG, DCIs were also significantly smaller in CON (P < 0.05). A comparison of mild CON and mild NTG (mean deviation (MD) > -6 dB), in which the extent of retinal nerve fiber layer thinning is comparable, the DCIs of mild CON were significantly smaller than those of mild NTG (P < 0.05). In contrast, DCIs did not differ between moderate-to-severe stages of CON and NTG (MD ≤ -6 dB), though the retinal nerve fibers of CON were more severely damaged than those of NTG. To differentiate between mild CON and mild NTG, all AUROCs for the three DCIs were above 0.700. A quantitative and objective assessment of optic disc color was useful in differentiating early-stage CON from GON and NOR.
Retinitis pigmentosa inversa with unilateral high myopia with fellow eye optic disc pitting.
Sheth, Saumil; Rush, Ryan; Narayanan, Raja
2011-01-01
To report a possible rare association of bilateral retinitis pigmentosa inversa (RPI) with unilateral high myopia with fellow eye optic disc pitting. A 55-year-old man with a history of reduced vision in the right eye since childhood presented with gradually decreasing vision in the left eye. On examination, a -23.00 diopter refractive error and diffuse chorioretinal atrophy consistent with pathologic myopia was found in the right eye. An optic disc pit with posterior pole pigmentary alterations thought to be consequent to a previous neurosensory detachment was found in the left eye. Though the retinal arteriolar attenuation seen in both eyes with an inconsistent history of night blindness since childhood pointed towards the possibility of a concurrently existing rod or rod-cone dystrophy, the posterior pole pigmentary alterations characteristic of RPI were clearly masked by the above pathologies. Optical coherence tomography demonstrated prominent foveal atrophy and an optic disc pit in the left eye. Electroretinography (ERG) demonstrated moderately attenuated amplitudes with prolonged implicit times of rod and cone responses bilaterally. The patient was diagnosed with bilateral RPI and anisometropic amblyopia in the right eye. This report documents a unique constellation of findings which include bilateral RPI and unilateral high myopia with an optic disc pit in the fellow eye. An ERG confirmation of a dystrophic etiology should be sought in suspicious cases, especially when findings are masked by the concurrent presence of other pathologies.
Tagawa, Yoshiaki; Suzuki, Yasuo; Sakaguchi, Takatoshi; Endoh, Hiroki; Yokoi, Masahiko; Kase, Manabu
2014-01-01
A 29-year-old fisherman exhibited optic disc oedema and peripapillary retinal detachment in the right eye, whereas in the left eye, optic atrophy and intraretinal exudates were already observed on first examination. About 6 months earlier, he noticed blurred vision of the left eye but took no medication. Visual acuity was 0.4 OD and 0.01 OS. Perimetry showed a large lower-half field defect with sparing 10° central field in the right eye and a large central scotoma in the left eye. Fluorescein angiography showed existence of arteriole or capillary nonperfusion and hyperpermeability of surrounding capillaries. Since serological examinations showed positive Bartonella immunoglobulin G (IgG) and other causes of neuroretinitis (NR) were excluded, NR in the present case was caused by cat scratch disease (CSD). Optic atrophy appeared 2 weeks after onset. Optical coherence tomography 13 weeks after onset revealed severe loss of retinal nerve fibre layer (RNFL) superior and nasal to the optic disc in both eyes and temporal in the left eye. Visual acuity of the right eye improved to 1.2 by the treatment, whereas visual field defects were persistent. CSD-NR in the present case developed abrupt appearance of optic atrophy with severe RNFL loss in the right eye, which was elicited by exudative, obliterative vasculitis in the superficial layer of the optic disc.
Optical Disc Applications in Libraries.
ERIC Educational Resources Information Center
Andre, Pamela Q. J.
1989-01-01
Discusses a variety of library applications of optical disc storage technology, including CD-ROM, digital videodisc, and WORM. Research and development projects at the Library of Congress, National Library of Medicine, and National Agricultural Library are described, products offered by library networks are reviewed, and activities in academic and…
NASA Astrophysics Data System (ADS)
Irmler, Frank; Creutzburg, Reiner
2014-02-01
This paper deals with the possibilities of retracing copyright violations on current video game consoles (e.g. Microsoft Xbox, Sony PlayStation, ...) by studying the corresponding optical storage media DVD and Blu-ray. The possibilities of forensic investigation of DVD and Blu-ray Discs are presented. It is shown which information can be read by using freeware and commercial software for forensic examination. A detailed analysis is given on the visualization of hidden content and the possibility to find out information about the burning hardware used for writing on the optical discs. In connection with a forensic analysis of the Windows registry of a suspects PC a detailed overview of the crime scene for forged DVD and Blu-ray Discs can be obtained. Optical discs are examined under forensic aspects and the obtained results are implemented into automatic analysis scripts for the commercial forensics program EnCase Forensic. It is shown that for the optical storage media a possibility of identification of the drive used for writing can be obtained. In particular Blu-ray Discs contain the serial number of the burner. These and other findings were incorporated into the creation of various EnCase scripts for the professional forensic investigation with EnCase Forensic. Furthermore, a detailed flowchart for a forensic investigation of copyright infringement was developed.
The extremely truncated circumstellar disc of V410 X-ray 1: a precursor to TRAPPIST-1?
NASA Astrophysics Data System (ADS)
Boneberg, D. M.; Facchini, S.; Clarke, C. J.; Ilee, J. D.; Booth, R. A.; Bruderer, S.
2018-06-01
Protoplanetary discs around brown dwarfs and very low mass (VLM) stars offer some of the best prospects for forming Earth-sized planets in their habitable zones. To this end, we study the nature of the disc around the VLM star V410 X-ray 1, whose spectral energy distribution (SED) is indicative of an optically thick and very truncated dust disc, with our modelling suggesting an outer radius of only 0.6 au. We investigate two scenarios that could lead to such a truncation, and find that the observed SED is compatible with both. The first scenario involves the truncation of both the dust and gas in the disc, perhaps due to a previous dynamical interaction or the presence of an undetected companion. The second scenario involves the fact that a radial location of 0.6 au is close to the expected location of the H2O snowline in the disc. As such, a combination of efficient dust growth, radial migration, and subsequent fragmentation within the snowline leads to an optically thick inner dust disc and larger, optically thin outer dust disc. We find that a firm measurement of the CO J = 2-1 line flux would enable us to distinguish between these two scenarios, by enabling a measurement of the radial extent of gas in the disc. Many models we consider contain at least several Earth-masses of dust interior to 0.6 au, suggesting that V410 X-ray 1 could be a precursor to a system with tightly packed inner planets, such as TRAPPIST-1.
Maertz, Josef; Kolb, Jan Philip; Klein, Thomas; Mohler, Kathrin J; Eibl, Matthias; Wieser, Wolfgang; Huber, Robert; Priglinger, Siegfried; Wolf, Armin
2018-02-01
To demonstrate papillary imaging of eyes with optic disc pits (ODP) or optic disc pit associated maculopathy (ODP-M) with ultrahigh-speed swept-source optical coherence tomography (SS-OCT) at 1.68 million A-scans/s. To generate 3D-renderings of the papillary area with 3D volume-reconstructions of the ODP and highly resolved en face images from a single densely-sampled megahertz-OCT (MHz-OCT) dataset for investigation of ODP-characteristics. A 1.68 MHz-prototype SS-MHz-OCT system at 1050 nm based on a Fourier-domain mode-locked laser was employed to acquire high-definition, 3D datasets with a dense sampling of 1600 × 1600 A-scans over a 45° field of view. Six eyes with ODPs, and two further eyes with glaucomatous alteration or without ocular pathology are presented. 3D-rendering of the deep papillary structures, virtual 3D-reconstructions of the ODPs and depth resolved isotropic en face images were generated using semiautomatic segmentation. 3D-rendering and en face imaging of the optic disc, ODPs and ODP associated pathologies showed a broad spectrum regarding ODP characteristics. Between individuals the shape of the ODP and the appending pathologies varied considerably. MHz-OCT en face imaging generates distinct top-view images of ODPs and ODP-M. MHz-OCT generates high resolution images of retinal pathologies associated with ODP-M and allows visualizing ODPs with depths of up to 2.7 mm. Different patterns of ODPs can be visualized in patients for the first time using 3D-reconstructions and co-registered high-definition en face images extracted from a single densely sampled 1050 nm megahertz-OCT (MHz-OCT) dataset. As the immediate vicinity to the SAS and the site of intrapapillary proliferation is located at the bottom of the ODP it is crucial to image the complete structure and the whole depth of ODPs. Especially in very deep pits, where non-swept-source OCT fails to reach the bottom, conventional swept-source devices and the MHz-OCT alike are feasible and beneficial methods to examine deep details of optic disc pathologies, while the MHz-OCT bears the advantage of an essentially swifter imaging process.
Optical Disc Technology for Information Management.
ERIC Educational Resources Information Center
Brumm, Eugenia K.
1991-01-01
This summary of the literature on document image processing from 1988-90 focuses on WORM (write once read many) technology and on rewritable (i.e., erasable) optical discs, and excludes CD-ROM. Highlights include vendors and products, standards, comparisons of storage media, software, legal issues, records management, indexing, and computer…
Choosing an Optical Disc System: A Guide for Users and Resellers.
ERIC Educational Resources Information Center
Vane-Tempest, Stewart
1995-01-01
Presents a guide for selecting an optional disc system. Highlights include storage hierarchy; standards; data life cycles; security; implementing an optical jukebox system; optimizing the system; performance; quality and reliability; software; cost of online versus near-line; and growing opportunities. Sidebars provide additional information on…
Loukianou, Eleni; Kisma, Nacima; Pal, Bishwanathan
2011-02-02
To report photographically the evolution of an astrocytic hamartoma of the left optic nerve head over a 2-year follow-up in a patient with retinitis pigmentosa. A 14-year-old boy was seen in the medical retina clinic with a 3-year history of night blindness. Best corrected visual acuity was 6/18 in both eyes. Colour vision was normal in both eyes and confrontation fields showed peripheral constriction. Fundus examination revealed bone spicule pigmentary changes at the retinal mid periphery typical of retinitis pigmentosa and superficial globules at the margins of both optic nerve heads. Electrodiagnostic tests confirmed moderately severe rod cone dystrophy with macular involvement bilaterally. Two years later, the ocular examination was unchanged except for the appearance of the optic nerve head lesion in the left eye. There was an increase in the size of the lesion which was diagnosed as an astrocytic hamartoma. Further investigations were recommended to exclude neurofibromatosis and tuberous sclerosis. Astrocytic hamartomas of the optic nerve head and optic nerve head drusen have both been described in patients with retinitis pigmentosa. They can be a diagnostic dilemma although drusen are more common (10%). To differentiate these two entities it is very important to document any growth during the follow-up period which is suggestive of astrocytic hamartoma rather than optic disc drusen.
Choi, Stacey S; Zawadzki, Robert J; Greiner, Mark A; Werner, John S; Keltner, John L
2008-06-01
New technology allows more precise definition of structural alterations of all retinal layers although it has not been used previously in cases of optic disc drusen. Using Stratus and Fourier domain (FD) optical coherence tomography (OCT) and adaptive optics (AO) through a flood-illuminated fundus camera, we studied the retinas of a patient with long-standing optic disc drusen and acute visual loss at high altitude attributed to ischemic optic neuropathy. Stratus OCT and FD-OCT confirmed severe thinning of the retinal nerve fiber layer (RNFL). FD-OCT revealed disturbances in the photoreceptor layer heretofore not described in optic disc drusen patients. AO confirmed the FD-OCT findings in the photoreceptor layer and also showed reduced cone density at retinal locations associated with reduced visual sensitivity. Based on this study, changes occur not only in the RNFL but also in the photoreceptor layer in optic nerve drusen complicated by ischemic optic neuropathy. This is the first reported application of FD-OCT and the AO to this condition. Such new imaging technology may in the future allow monitoring of disease progression more precisely and accurately.
Adapter plate assembly for adjustable mounting of objects
Blackburn, R.S.
1986-05-02
An adapter plate and two locking discs are together affixed to an optic table with machine screws or bolts threaded into a fixed array of internally threaded holes provided in the table surface. The adapter plate preferably has two, and preferably parallel, elongated locating slots each freely receiving a portion of one of the locking discs for secure affixation of the adapter plate to the optic table. A plurality of threaded apertures provided in the adapter plate are available to attach optical mounts or other devices onto the adapter plate in an orientation not limited by the disposition of the array of threaded holes in the table surface. An axially aligned but radially offset hole through each locking disc receives a screw that tightens onto the table, such that prior to tightening of the screw the locking disc may rotate and translate within each locating slot of the adapter plate for maximum flexibility of the orientation thereof.
Adapter plate assembly for adjustable mounting of objects
Blackburn, Robert S.
1987-01-01
An adapter plate and two locking discs are together affixed to an optic table with machine screws or bolts threaded into a fixed array of internally threaded holes provided in the table surface. The adapter plate preferably has two, and preferably parallel, elongated locating slots each freely receiving a portion of one of the locking discs for secure affixation of the adapter plate to the optic table. A plurality of threaded apertures provided in the adapter plate are available to attach optical mounts or other devices onto the adapter plate in an orientation not limited by the disposition of the array of threaded holes in the table surface. An axially aligned but radially offset hole through each locking disc receives a screw that tightens onto the table, such that prior to tightening of the screw the locking disc may rotate and translate within each locating slot of the adapter plate for maximum flexibility of the orientation thereof.
Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung
2016-01-01
Purpose To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. Methods A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Results Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Conclusions Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size. PMID:27490718
Adalimumab and Non-Arteritic Anterior Ischaemic Optic Neuropathy: A Case Report.
Kinard, Krista; Walsh, Jessica A; Penmetsa, Gopi K; Warner, Judith E A
2014-01-01
Sequential anterior ischaemic optic neuropathy was observed in a patient treated with a tumour necrosis factor α (TNF) inhibitor, adalimumab, for ankylosing spondylitis. He developed decreased visual acuity in the right eye after 17 months of treatment. Findings showed right optic disc oedema with haemorrhages and visual field defect. Adalimumab was discontinued and vision stabilised. After restarting adalimumab, he developed optic neuropathy in the left eye. Findings showed optic disc oedema, with haemorrhages and visual field changes in the left eye. Adalimumab may be associated with optic neuropathy; providers prescribing TNF inhibitors should be aware of optic neuropathy as a potential complication.
A multiscale decomposition approach to detect abnormal vasculature in the optic disc.
Agurto, Carla; Yu, Honggang; Murray, Victor; Pattichis, Marios S; Nemeth, Sheila; Barriga, Simon; Soliz, Peter
2015-07-01
This paper presents a multiscale method to detect neovascularization in the optic disc (NVD) using fundus images. Our method is applied to a manually selected region of interest (ROI) containing the optic disc. All the vessels in the ROI are segmented by adaptively combining contrast enhancement methods with a vessel segmentation technique. Textural features extracted using multiscale amplitude-modulation frequency-modulation, morphological granulometry, and fractal dimension are used. A linear SVM is used to perform the classification, which is tested by means of 10-fold cross-validation. The performance is evaluated using 300 images achieving an AUC of 0.93 with maximum accuracy of 88%. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Pahari, Mayukh; Gandhi, Poshak; Charles, Philip A.; Kotze, Marissa M.; Altamirano, Diego; Misra, Ranjeev
2017-07-01
We present results from simultaneous optical [South African Large Telescope (SALT)] and X-ray (Swift and INTEGRAL) observations of GS 1354-64/BW Cir during the 2015 hard state outburst. During the rising phase, optical/X-ray time series shows a strong anti-correlation with X-ray photons lagging optical. Optical and X-ray power spectra show quasi-periodic oscillations (QPOs) at a frequency of ˜18 mHz with a confidence level of at least 99 per cent. Simultaneous fitting of Swift/XRT and INTEGRAL spectra in the range 0.5-1000.0 keV shows non-thermal, power-law-dominated (>90 per cent) spectra with a hard power-law index of 1.48 ± 0.03, inner disc temperature of 0.12 ± 0.01 keV and an inner disc radius of ˜3000 km. All evidence is consistent with cyclo-synchrotron radiation in a non-thermal, hot electron cloud extending to ˜100 Schwarzschild radii being a major physical process for the origin of optical photons. At outburst peak about one month later, when the X-ray flux rises and the optical drops, the apparent features in the optical/X-ray correlation vanish and the optical auto correlation widens. Although ˜0.19 Hz QPO is observed from the X-ray power spectra, the optical variability is dominated by the broad-band noise, and the inner disc temperature increases. These results support a change in the dominant optical emission source between outburst rise and peak, consistent with a weakening of hot flow as the disc moves in.
Kim, Ji Hong; Kang, Min Ho; Seong, Mincheol; Cho, Heeyoon; Shin, Yong Un
2018-04-01
Non-arteritic anterior ischemic optic neuropathy (NAION) is characterized by sudden, painless visual loss and optic disc edema. NAION occurs mainly in the presence of cardiovascular disease and hypercoagulability, mainly in patients over 50 years of age. We experienced a case of NAION associated with central retinal vein occlusion (CRVO) in a young man with no underlying disease. A 46-year-old man was referred to our clinic following a sudden loss of vision in his right eye. The patient exhibited no underlying disease and reported no ongoing medication. Significant visual loss and visual disturbance of the right eye were observed. The pupil of the right eye was enlarged and an afferent pupillary defect was observed. On fundus examination, retinal hemorrhage was observed in the peripheral retina; macular edema was observed in optical coherence tomography analysis. However, optic disc edema was not evident. No abnormal findings were found in routine blood tests for hypercoagulability. After 3 days of steroid intravenous injection, macular edema disappeared and visual acuity was improved, but optic disc edema began to appear. One week later, optic disc edema was evident and visual acuity was significantly reduced; thus, the patient was diagnosed with NAION. In fluorescein angiography, peripheral retinal ischemia was observed, suggesting that CRVO was complicated. Blood tests, including analysis of coagulation factors, were performed again, showing that coagulation factors IX and XI were increased. Anomalous coagulation factors in non-arteritic anterior ischemic optic neuropathy with central retinal vein occlusion. Systemic steroids were administered. One month later, optic disc edema and retinal hemorrhage gradually diminished and eventually disappeared; however, visual acuity did not recover. In young patients without underlying disease, cases of NAION require careful screening for coagulation disorders. Even if there is no abnormality in the test for routine coagulation status, it may be necessary to confirm a coagulation defect through an additional coagulation factor assay.
Progress in Electron Beam Mastering of 100 Gbit/inch2 Density Disc
NASA Astrophysics Data System (ADS)
Takeda, Minoru; Furuki, Motohiro; Yamamoto, Masanobu; Shinoda, Masataka; Saito, Kimihiro; Aki, Yuichi; Kawase, Hiroshi; Koizumi, Mitsuru; Miyokawa, Toshiaki; Mutou, Masao; Handa, Nobuo
2004-07-01
We developed an electron beam recorder (EBR) capable of recording master discs under atmospheric conditions using a novel differential pumping head. Using the EBR and optimized fabrication process for Si-etched discs with reactive ion etching (RIE), a bottom signal jitter of 9.6% was obtained from a 36 Gbit/inch2 density disc, readout using a near-field optical pickup with an effective numerical aperture (NA) of 1.85 and a wavelength of 405 nm. We also obtained the eye patterns from a 70 Gbit/inch2 density disc readout using an optical pickup with a 2.05 NA and the same wavelength, and showed almost the same modulation ratio as the simulation value. Moreover, the capability of producing pit patterns corresponding to a 104 Gbit/inch2 density is demonstrated.
ERIC Educational Resources Information Center
Chen, Ching-chih
1986-01-01
This discussion of information technology and its impact on library operations and services emphasizes the development of microcomputer and laser optical disc technologies. Libraries' earlier responses to bibliographic utilities, online databases, and online public access catalogs are described, and future directions for library services are…
ELNET--The Electronic Library Database System.
ERIC Educational Resources Information Center
King, Shirley V.
1991-01-01
ELNET (Electronic Library Network), a Japanese language database, allows searching of index terms and free text terms from articles and stores the full text of the articles on an optical disc system. Users can order fax copies of the text from the optical disc. This article also explains online searching and discusses machine translation. (LRW)
Modeling the Compact Disc Read System in Lab
ERIC Educational Resources Information Center
Hinaus, Brad; Veum, Mick
2009-01-01
One of the great, engaging aspects of physics is its application to everyday technology. The compact disc player is an example of one such technology that applies fundamental principles from optics in order to efficiently store and quickly retrieve information. We have created a lab in which students use simple optical components to assemble a…
Longitudinal changes in the visual field and optic disc in glaucoma.
Artes, Paul H; Chauhan, Balwantray C
2005-05-01
The nature and mode of functional and structural progression in open-angle glaucoma is a subject of considerable debate in the literature. While there is a traditionally held viewpoint that optic disc and/or nerve fibre layer changes precede visual field changes, there is surprisingly little published evidence from well-controlled prospective studies in this area, specifically with modern perimetric and imaging techniques. In this paper, we report on clinical data from both glaucoma patients and normal controls collected prospectively over several years, to address the relationship between visual field and optic disc changes in glaucoma using standard automated perimetry (SAP), high-pass resolution perimetry (HRP) and confocal scanning laser tomography (CSLT). We use several methods of analysis of longitudinal data and describe a new technique called "evidence of change" analysis which facilitates comparison between different tests. We demonstrate that current clinical indicators of visual function (SAP and HRP) and measures of optic disc structure (CSLT) provide largely independent measures of progression. We discuss the reasons for these findings as well as several methodological issues that pose challenges to elucidating the true structure-function relationship in glaucoma.
Kawano, K; Ito, Y; Kondo, M; Ishikawa, K; Kachi, S; Ueno, S; Iguchi, Y; Terasaki, H
2013-07-01
To determine whether there is a displacement of the fovea toward the optic disc after successful macular hole (MH) surgery with internal limiting membrane (ILM) peeling. The medical records of 54 eyes of 53 patients that had undergone pars plana vitrectomy with ILM peeling and gas or air tamponade for an idiopathic MH were evaluated. Spectral-domain optical coherence tomography (OCT) had been performed before and >6 months after the surgery. The preoperative distances between the center of the MH and the optic disc (MH-OD), center of the MH and the bifurcation or crossing of retinal vessels (MH-RV) were measured in the OCT images. In addition, the postoperative distance between the center of the fovea and optic disc (F-OD) and the center of the fovea and the same bifurcation or crossing of retinal vessels (F-RV) were measured in the OCT images. The F-OD was 2.67±0.33 disc diameters (DD), which was significantly shorter than that of the MH-OD of 2.77±0.33 DD (P<0.001). The F-RV was also significantly shorter than the MH-RV on the inner nasal area (from 0.85±0.16DD to 0.79±0.15DD; P<0.001), the inner temporal area (from 0.82±0.15DD to 0.77±0.14DD; P<0.001), and outer nasal area (from 1.70±0.31DD to 1.65±0.32DD; P<0.001), but it was significantly longer than the MH-RV in the outer temporal area (from 1.65±0.29DD to 1.68±0.29DD; P<0.001). Our results showed that successful closure of a MH by vitrectomy with ILM peeling and gas tamponade leads to a displacement of the center of the macula toward the optic disc.
Influence of plasmon destructive interferences on optical properties of gold planar quadrumers.
Rahmani, M; Tahmasebi, T; Lin, Y; Lukiyanchuk, B; Liew, T Y F; Hong, M H
2011-06-17
Arrays of planar symmetric gold quadrumers consisting of a central nano-disc surrounded by three similar nano-discs belonging to the D(3h) point group were designed and fabricated. Since the geometrical configuration of quadrumers is the same as planar trigonal molecules, nano-discs can play the roles of artificial atoms to study the coupling trends among them. The plasmonic properties of the nano-disc structures are investigated by reflection spectrum measurement and finite-difference time-domain calculation with good agreement. Plasmon interaction among the nano-discs is also studied via a mass-spring coupled oscillator model. A pronounced Fano resonance (FR) is observed for the fabricated nano-discs with inter-disk gaps of around 18 nm during light irradiation at normal incidence. Although the obtained FR is independent of the excitation polarization, the near-field energy spatial distribution can be flexibly tuned by the polarization direction. This has potential applications in nano-lithography, optical switching and nonlinear spectroscopy.
Preliminary optical coherence tomography investigation of the temporo-mandibular joint disc
NASA Astrophysics Data System (ADS)
Mărcăuteanu, Corina; Demjan, Enikö; Sinescu, Cosmin; Negrutiu, Meda; Motoc, Adrian; Lighezan, Rodica; Vasile, Liliana; Hughes, Mike; Bradu, Adrian; Dobre, George; Podoleanu, Adrian G.
2010-02-01
Aim and objectives. The morphology and position of the temporo-mandibular disc are key issues in the diagnosis and treatment of arthrogenous temporo-mandibular disorders. Magnetic resonance imaging and arthroscopy are used today to identify: flattening of the pars posterior of the disc, perforation and/or adhesions in the pars intermedia of the disc and disc displacements. The present study proposes the investigation of the temporo-mandibular joint disc by optical coherence tomography (OCT). Material and methods. 8 human temporo-mandibular joint discs were harvested from dead subjects, under 40 year of age, and conserved in formalin. They had a normal morphology, with a thicker pars posterior (2,6 mm on the average) and a thinner pars intermedia (1mm on the average). We investigated the disc samples using two different OCT systems: an en-face OCT (time domain (TD)-OCT) system, working at 1300 nm (C-scan and B-scan mode) and a spectral OCT system (a Fourier domain (FD)-OCT) system , working at 840 nm (B-scan mode). Results. The OCT investigation of the temporo-mandibular joint discs revealed a homogeneous microstructure. The longer wavelength of the TD-OCT offers a higher penetration depth (2,5 mm in air), which is important for the analysis of the pars posterior, while the FD-OCT is much faster. Conclusions: OCT is a promising imaging method for the microstructural characterization of the temporo-mandibular disc.
Retinoschisis and neurosensory detachment in advanced focal glaucoma.
Arranz-Márquez, E; Jarrín Hernández, E; Pastor, A; García Gil de Bernabé, J
2017-10-01
A 71-year-old woman with normotensive primary open-angle glaucoma presented with an asymptomatic temporal peripapillary retinoschisis, associated with serous retinal detachment in the eye with the more advanced glaucoma. It was located at the inferior pole of the optic disc, in the proximity of a glaucomatous focal disc defect. Although congenital optic pits are strongly related with juxta-papillary retinoschisis, retinoschisis can also arise from acquired defects in the proximity of glaucomatous optic discs. As symptoms depend on the extent of the retinoschisis, the prevalence of this complication could be greater than that reported in glaucomatous eyes. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
Huang, David; Chopra, Vikas; Lu, Ake Tzu-Hui; Tan, Ou; Francis, Brian; Varma, Rohit
2012-01-01
Purpose. To determine the relationship between retinal nerve fiber layer (RNFL) thickness, optic disc size, and image magnification. Methods. The cohort consisted of 196 normal eyes of 101 participants in the Advanced Imaging for Glaucoma Study (AIGS), a multicenter, prospective, longitudinal study to develop advanced imaging technologies for glaucoma diagnosis. Scanning laser tomography was used to measure disc size. Optical coherence tomography (OCT) was used to perform circumpapillary RNFL thickness measurements using the standard fixed 3.46-mm nominal scan diameter. A theoretical model of magnification effects was developed to relate RNFL thickness (overall average) with axial length and magnification. Results. Multivariate regression showed no significant correlation between RNFL thickness and optic disc area (95% confidence interval [CI] = −0.9 to 4.1 μm/mm2, P = 0.21). Linear regression showed that RNFL thickness depended significantly on axial length (slope = −3.1 μm/mm, 95% CI = −4.9 to −1.3, P = 0.001) and age (slope = −0.3 μm/y, 95% CI = −0.5 to −0.2, P = 0.0002). The slope values agreed closely with the values predicted by the magnification model. Conclusions. There is no significant association between RNFL thickness and optic disc area. Previous publications that showed such an association may have been biased by the effect of axial length on fundus image magnification and, therefore, both measured RNFL thickness and apparent disc area. The true diameter of the circumpapillary OCT scan is larger for a longer eye (more myopic eye), leading to a thinner RNFL measurement. Adjustment of measured RNFL thickness by axial length, in addition to age, may lead to a tighter normative range and improve the detection of RNFL thinning due to glaucoma. PMID:22743319
Kanaan, M Z; Lorenzi, A R; Thampy, N; Pandit, R; Dayan, Margaret
2017-12-01
A 75-year-old hypertensive female with stable idiopathic intermediate uveitis presented with bilateral sequential optic neuropathy with optic disc swelling. The optic neuropathy in the first affected eye (right) was thought to be due to non-arteritic anterior ischaemic optic neuropathy (NAION). Asymptomatic left optic disc swelling was found at routine review 2 months later, and a diagnosis of giant cell arteritis (GCA) was sought. Temporal artery duplex ultrasound showed the "halo sign," but a subsequent temporal artery biopsy showed light-chain (AL) amyloidosis with no signs of giant cell arteritis. In this case, bilateral sequential ischaemic optic neuropathy mimicking non-arteritic anterior ischaemic optic neuropathy was the presenting sign of systemic amyloidosis involving the temporal arteries.
Photoreceptor disc shedding in the living human eye
Kocaoglu, Omer P.; Liu, Zhuolin; Zhang, Furu; Kurokawa, Kazuhiro; Jonnal, Ravi S.; Miller, Donald T.
2016-01-01
Cone photoreceptors undergo a daily cycle of renewal and shedding of membranous discs in their outer segments (OS), the portion responsible for light capture. These physiological processes are fundamental to maintaining photoreceptor health, and their dysfunction is associated with numerous retinal diseases. While both processes have been extensively studied in animal models and postmortem eyes, little is known about them in the living eye, in particular human. In this study, we report discovery of the optical signature associated with disc shedding using a method based on adaptive optics optical coherence tomography (AO-OCT) in conjunction with post-processing methods to track and monitor individual cone cells in 4D. The optical signature of disc shedding is characterized by an abrupt transient loss in the cone outer segment tip (COST) reflection followed by its return that is axially displaced anteriorly. Using this signature, we measured the temporal and spatial properties of shedding events in three normal subjects. Average duration of the shedding event was 8.8 ± 13.4 minutes, and average length loss of the OS was 2.1 μm (7.0% of OS length). Prevalence of cone shedding was highest in the morning (14.3%) followed by the afternoon (5.7%) and evening (4.0%), with load distributed across the imaged patch. To the best of our knowledge these are the first images of photoreceptor disc shedding in the living retina. PMID:27895995
NASA Astrophysics Data System (ADS)
Liu, J.; Wong, D. W. K.; Lim, J. H.; Li, H.; Tan, N. M.; Wong, T. Y.
2009-02-01
Glaucoma is an irreversible ocular disease leading to permanent blindness. However, early detection can be effective in slowing or halting the progression of the disease. Physiologically, glaucoma progression is quantified by increased excavation of the optic cup. This progression can be quantified in retinal fundus images via the optic cup to disc ratio (CDR), since in increased glaucomatous neuropathy, the relative size of the optic cup to the optic disc is increased. The ARGALI framework constitutes of various segmentation approaches employing level set, color intensity thresholds and ellipse fitting for the extraction of the optic cup and disc from retinal images as preliminary steps. Following this, different combinations of the obtained results are then utilized to calculate the corresponding CDR values. The individual results are subsequently fused using a neural network. The learning function of the neural network is trained with a set of 100 retinal images For testing, a separate set 40 images is then used to compare the obtained CDR against a clinically graded CDR, and it is shown that the neural network-based result performs better than the individual components, with 96% of the results within intra-observer variability. The results indicate good promise for the further development of ARGALI as a tool for the early detection of glaucoma.
Parikakis, Efstratios A; Chatziralli, Irini P; Peponis, Vasileios G; Karagiannis, Dimitrios; Stratos, Aimilianos; Tsiotra, Vasileia A; Mitropoulos, Panagiotis G
2014-01-01
To report a case of spontaneous resolution of a long-standing serous macular detachment associated with an optic disc pit, leading to significant visual improvement. A 63-year-old female presented with a 6-month history of blurred vision and micropsia in her left eye. Her best-corrected visual acuity was 6/24 in the left eye, and fundoscopy revealed serous macular detachment associated with optic disc pit, which was confirmed by optical coherence tomography (OCT). The patient was offered vitrectomy as a treatment alternative, but she preferred to be reviewed conservatively. Three years after initial presentation, neither macular detachment nor subretinal fluid was evident in OCT, while the inner segment/outer segment (IS/OS) junction line was intact. Her visual acuity was improved from 6/24 to 6/12 in her left eye, remaining stable at the 6-month follow-up after resolution. We present a case of spontaneous resolution of a long-standing macular detachment associated with an optic disc pit with significant visual improvement, postulating that the integrity of the IS/OS junction line may be a prognostic factor for final visual acuity and suggesting OCT as an indicator of visual prognosis and the probable necessity of a surgical management.
African Descent and Glaucoma Evaluation Study (ADAGES)
Girkin, Christopher A.; Sample, Pamela A.; Liebmann, Jeffrey M.; Jain, Sonia; Bowd, Christopher; Becerra, Lida M.; Medeiros, Felipe A.; Racette, Lyne; Dirkes, Keri A.; Weinreb, Robert N.; Zangwill, Linda M.
2010-01-01
Objective To define differences in optic disc, retinal nerve fiber layer, and macular structure between healthy participants of African (AD) and European descent (ED) using quantitative imaging techniques in the African Descent and Glaucoma Evaluation Study (ADAGES). Methods Reliable images were obtained using stereoscopic photography, confocal scanning laser ophthalmoscopy (Heidelberg retina tomography [HRT]), and optical coherence tomography (OCT) for 648 healthy subjects in ADAGES. Findings were compared and adjusted for age, optic disc area, and reference plane height where appropriate. Results The AD participants had significantly greater optic disc area on HRT (2.06 mm2; P<.001) and OCT (2.47 mm2; P<.001) and a deeper HRT cup depth than the ED group (P<.001). Retinal nerve fiber layer thickness was greater in the AD group except within the temporal region, where it was significantly thinner. Central macular thickness and volume were less in the AD group. Conclusions Most of the variations in optic nerve morphologic characteristics between the AD and ED groups are due to differences in disc area. However, differences remain in HRT cup depth, OCT macular thickness and volume, and OCT retinal nerve fiber layer thickness independent of these variables. These differences should be considered in the determination of disease status. PMID:20457974
NASA Astrophysics Data System (ADS)
Alfonso-Garzón, J.; Fabregat, J.; Reig, P.; Kajava, J. J. E.; Sánchez-Fernández, C.; Townsend, L. J.; Mas-Hesse, J. M.; Crawford, S. M.; Kretschmar, P.; Coe, M. J.
2017-11-01
Context. Multiwavelength monitoring of Be/X-ray binaries is crucial to understand the mechanisms producing their outbursts. H 1145-619 is one of these systems, which has recently displayed X-ray activity. Aims: We investigate the correlation between the optical emission and X-ray activity to predict the occurrence of new X-ray outbursts from the inferred state of the circumstellar disc. Methods: We have performed a multiwavelength study of H 1145-619 from 1973 to 2017 and present here a global analysis of its variability over the last 40 yr. We used optical spectra from the SAAO, SMARTS, and SALT telescopes and optical photometry from the Optical Monitoring Camera (OMC) onboard INTEGRAL and from the All Sky Automated Survey (ASAS). We also used X-ray observations from INTEGRAL/JEM-X, and IBIS to generate the light curves and combined them with Swift/XRT to extract the X-ray spectra. In addition, we compiled archival observations and measurements from the literature to complement these data. Results: Comparing the evolution of the optical continuum emission with the Hα line variability, we identified three different patterns of optical variability: first, global increases and decreases of the optical brightness, observed from 1982 to 1994 and from 2009 to 2017, which can be explained by the dissipation and replenishment of the circumstellar disc; second, superorbital variations with a period of Psuperorb ≈ 590 days, observed in 2002-2009, which seems to be related to the circumstellar disc; and third, optical outbursts, observed in 1998-1999 and 2002-2005, which we interpret as mass ejections from the Be star. We discovered the presence of a retrograde one-armed density wave, which appeared in 2016 and is still present in the circumstellar disc. Conclusions: We carried out the most complete long-term optical study of the Be/X-ray binary H 1145-619 in correlation with its X-ray activity. For the first time, we found the presence of a retrograde density perturbation in the circumstellar disc of a Be/X-ray binary.
Chronic optic disc swelling overlooked in a diabetic patient with a devastating outcome
Braithwaite, Tasanee; Plant, Gordon T
2010-01-01
We present a case of asymmetrical but bilateral, progressive, painless visual deterioration over 5 years to no perception of light, in a 61-year-old male diabetic patient referred for a second opinion. The patient had a chronic history of bilateral diabetic maculopathy and unexplained swelling of the optic discs. He was diagnosed with optic atrophy secondary to pseudotumour cerebri (termed idiopathic intracranial hypertension when underlying causes have been excluded), which was associated with obstructive sleep apnoea. The case highlights the critical importance of identifying and investigating chronic papilloedema for reversible causes; the sometimes subtle presentation of pseudotumour cerebri; and the vital role of visual field testing and diagnostic lumbar puncture for timely diagnosis. It also reminds us that chronic bilateral optic disc swelling is not a normal feature of diabetic eye disease, and that alarm bells should sound if reduced visual acuity seems disproportionate to the degree of maculopathy. PMID:22442651
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finger, Paul T., E-mail: pfinger@eyecancer.com; Chin, Kimberly J.
2012-02-01
Purpose: To evaluate the intravitreal antivascular endothelial growth factor, bevacizumab, for treatment of radiation optic neuropathy (RON). Methods and Materials: A prospective interventional clinical case series was performed of 14 patients with RON related to plaque radiotherapy for choroidal melanoma. The RON was characterized by optic disc edema, hemorrhages, microangiopathy, and neovascularization. The entry criteria included a subjective or objective loss of vision, coupled with findings of RON. The study subjects received a minimum of two initial injections of intravitreal bevacizumab (1.25 mg in 0.05 mL) every 6-8 weeks. The primary objectives included safety and tolerability. The secondary objectives includedmore » the efficacy as measured using the Early Treatment Diabetic Retinopathy Study chart for visual acuity, fundus photography, angiography, and optical coherence tomography/scanning laser ophthalmoscopy. Results: Reductions in optic disc hemorrhage and edema were noted in all patients. The visual acuity was stable or improved in 9 (64%) of the 14 patients. Of the 5 patients who had lost vision, 2 had relatively large posterior tumors, 1 had had the vision decrease because of intraocular hemorrhage, and 1 had developed optic atrophy. The fifth patient who lost vision was noncompliant. No treatment-related ocular or systemic side effects were observed. Conclusions: Intravitreal antivascular endothelial growth factor bevacizumab was tolerated and generally associated with improved vision, reduced papillary hemorrhage, and resolution of optic disc edema. Persistent optic disc neovascularization and fluorescein angiographic leakage were invariably noted. The results of the present study support additional evaluation of antivascular endothelial growth factor medications as treatment of RON.« less
NASA Astrophysics Data System (ADS)
Lubow, Stephen H.; Ogilvie, Gordon I.
2017-08-01
Recent results by Martin et al. showed in 3D smoothed particle hydrodynamics simulations that tilted discs in binary systems can be unstable to the development of global, damped Kozai-Lidov (KL) oscillations in which the discs exchange tilt for eccentricity. We investigate the linear stability of KL modes for tilted inviscid discs under the approximations that the disc eccentricity is small and the disc remains flat. By using 1D equations, we are able to probe regimes of large ratios of outer to inner disc edge radii that are realistic for binary systems of hundreds of astronomical unit separations and are not easily probed by multidimensional simulations. For order unity binary mass ratios, KL instability is possible for a window of disc aspect ratios H/r in the outer parts of a disc that roughly scale as (nb/n)2 ≲ H/r ≲ nb/n, for binary orbital frequency nb and orbital frequency n at the disc outer edge. We present a framework for understanding the zones of instability based on the determination of branches of marginally unstable modes. In general, multiple growing eccentric KL modes can be present in a disc. Coplanar apsidal-nodal precession resonances delineate instability branches. We determine the range of tilt angles for unstable modes as a function of disc aspect ratio. Unlike the KL instability for free particles that involves a critical (minimum) tilt angle, disc instability is possible for any non-zero tilt angle depending on the disc aspect ratio.
Central corneal thickness and progression of the visual field and optic disc in glaucoma
Chauhan, B C; Hutchison, D M; LeBlanc, R P; Artes, P H; Nicolela, M T
2005-01-01
Aims: To determine whether central corneal thickness (CCT) is a significant predictor of visual field and optic disc progression in open angle glaucoma. Methods: Data were obtained from a prospective study of glaucoma patients tested with static automated perimetry and confocal scanning laser tomography every 6 months. Progression was determined using a trend based approach called evidence of change (EOC) analysis in which sectoral ordinal scores based on the significance of regression coefficients of visual field pattern deviation and neuroretinal rim area over time are summed. Visual field progression was also determined using the event based glaucoma change probability (GCP) analysis using both total and pattern deviation. Results: The sample contained 101 eyes of 54 patients (mean (SD) age 56.5 (9.8) years) with a mean follow up of 9.2 (0.7) years and 20.7 (2.3) sets of examinations every 6 months. Lower CCT was associated with worse baseline visual fields and lower mean IOP in the follow up. In the longitudinal analysis CCT was not correlated with the EOC scores for visual field or optic disc change. In the GCP analyses, there was a tendency for groups classified as progressing to have lower CCT compared to non-progressing groups. In a multivariate analyses accounting for IOP, the opposite was found, whereby higher CCT was associated with visual field progression. None of the independent factors were predictive of optic disc progression. Conclusions: In this cohort of patients with established glaucoma, CCT was not a useful index in the risk assessment of visual field and optic disc progression. PMID:16024855
Poland syndrome associated with 'morning glory' syndrome (coloboma of the optic disc).
Pisteljić, D T; Vranjesević, D; Apostolski, S; Pisteljić, D D
1986-01-01
A 12 year old girl with the Poland syndrome and the 'morning glory' syndrome is described. The patient presented with absence of the left pectoralis major muscle, hypoplasia of the left arm, symbrachydactyly, and ipsilateral coloboma of the optic disc. This is the first report of the association of these two congenital anomalies. Images PMID:3018249
Cywiński, Adam; Kałużny, Jakub; Ferda, Daniela; Piwońska-Lobermajer, Anna
2015-01-01
Retrospective evaluation of functional and anatomical treatment outcomes in patients with macular cornplications of optic disc pit. 9 patients (eyes) underwent central posterior vitrectomy in conjunction with posterior vitreous detachment, retinal laser therapy to the optic disc pit area and endotamponade with expansile gas. It was followed by the patient's forced positioning (recommended for a few days especially at night), which ended the treatment protocol. Improved anatomical relationships, accompanied by functional improvement were achieved in each reported case. The resolution of macular lesions was slow, lasting even for several months. Too long delay in performing the surgery (over 5 months since the onset of visual impairment) was associated with the development of retinal complications, mainly macular hole formation, most likely caused by the long-term ischemia. The central posterior vitrectomy combined with posterior vitreous detachment, laser therapy, andd expansile gas tamponade offers good outcomes in patients with retinal complications of optic disc pit. Surgery performed shortly after the onset of visual dysfunction gives the best functional outcomes. Restoration of normal anatomical relationships is a long-term process. In some cases, though, these abnormalities may not resolve completely.
Application of a relativistic accretion disc model to X-ray spectra of LMC X-1 and GRO J1655-40
NASA Astrophysics Data System (ADS)
Gierliński, Marek; Maciołek-Niedźwiecki, Andrzej; Ebisawa, Ken
2001-08-01
We present a general relativistic accretion disc model and its application to the soft-state X-ray spectra of black hole binaries. The model assumes a flat, optically thick disc around a rotating Kerr black hole. The disc locally radiates away the dissipated energy as a blackbody. Special and general relativistic effects influencing photons emitted by the disc are taken into account. The emerging spectrum, as seen by a distant observer, is parametrized by the black hole mass and spin, the accretion rate, the disc inclination angle and the inner disc radius. We fit the ASCA soft-state X-ray spectra of LMC X-1 and GRO J1655-40 by this model. We find that, having additional limits on the black hole mass and inclination angle from optical/UV observations, we can constrain the black hole spin from X-ray data. In LMC X-1 the constraint is weak, and we can only rule out the maximally rotating black hole. In GRO J1655-40 we can limit the spin much better, and we find 0.68<=a<=0.88. Accretion discs in both sources are radiation-pressure dominated. We do not find Compton reflection features in the spectra of any of these objects.
Loukianou, Eleni; Kisma, Nacima; Pal, Bishwanathan
2011-01-01
Aim To report photographically the evolution of an astrocytic hamartoma of the left optic nerve head over a 2-year follow-up in a patient with retinitis pigmentosa. Methods A 14-year-old boy was seen in the medical retina clinic with a 3-year history of night blindness. Best corrected visual acuity was 6/18 in both eyes. Colour vision was normal in both eyes and confrontation fields showed peripheral constriction. Fundus examination revealed bone spicule pigmentary changes at the retinal mid periphery typical of retinitis pigmentosa and superficial globules at the margins of both optic nerve heads. Electrodiagnostic tests confirmed moderately severe rod cone dystrophy with macular involvement bilaterally. Results Two years later, the ocular examination was unchanged except for the appearance of the optic nerve head lesion in the left eye. There was an increase in the size of the lesion which was diagnosed as an astrocytic hamartoma. Further investigations were recommended to exclude neurofibromatosis and tuberous sclerosis. Conclusion Astrocytic hamartomas of the optic nerve head and optic nerve head drusen have both been described in patients with retinitis pigmentosa. They can be a diagnostic dilemma although drusen are more common (10%). To differentiate these two entities it is very important to document any growth during the follow-up period which is suggestive of astrocytic hamartoma rather than optic disc drusen. PMID:21347192
Kon, Tomoya; Hikichi, Hiroki; Ueno, Tatsuya; Suzuki, Chieko; Nunomura, Jinichi; Kaneko, Kimihiko; Takahashi, Toshiyuki; Nakashima, Ichiro; Tomiyama, Masahiko
2018-05-18
Autoantibodies against myelin oligodendrocyte glycoprotein (MOG-IgG) have been detected in inflammatory demyelinating central nervous system diseases. A 30-year-old woman had blurred vision, marked optic nerve disc swelling, serous retinal detachment at the macular on optic coherence tomography, and MOG-IgG seropositivity. The patient was thought to have optic papillitis associated with MOG-IgG. Her symptoms rapidly improved after high-dose methylprednisolone therapy. We hypothesize that serous retinal detachment was secondary, arising from optic papillitis. This is the first report of the concurrence of optic papillitis with MOG-IgG and serous retinal detachment. MOG-IgG should be tested in patients with marked optic disc swelling.
Shin, Hye-Young; Park, Hae-Young Lopilly; Jung, Younhea; Choi, Jin-A; Park, Chan Kee
2014-10-01
To compare the initial visual field (VF) defect pattern and the spectral-domain optical coherence tomography (OCT) parameters and investigate the effects of distinct types of optic disc damage on the diagnostic performance of these OCT parameters in early glaucoma. Retrospective, observational study. A total of 138 control eyes and 160 eyes with early glaucoma were enrolled. The glaucomatous eyes were subdivided into 4 groups according to the type of optic disc damage: focal ischemic (FI) group, myopic (MY) group, senile sclerotic (SS) group, and generalized enlargement (GE) group. The values of total deviation (TD) maps were analyzed, and superior-inferior (S-I) differences of TD were calculated. The optic nerve head (ONH) parameters, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell-inner plexiform layer (GCIPL) thicknesses were measured. Comparison of diagnostic ability using area under the receiver operating characteristic curves (AUCs). The S-I and central S-I difference of the FI group were larger than those of the GE group. The rim area of the SS group was larger than those of the 3 other groups, and the vertical cup-to-disc ratio (CDR) of the GE group was larger than that of the MY group. In addition, the minimum and inferotemporal GCIPL thicknesses of the FI group were smaller than those of the GE group. The AUC of the rim area (0.89) was lower than that of the minimum GCIPL (0.99) in the SS group, and the AUC of the vertical CDR (0.90) was lower than that of the minimum GCIPL (0.99) in the MY group. Furthermore, the AUCs of the minimum GCIPL thicknesses of the FI and MY group were greater than those of the average pRNFL thickness for detecting glaucoma, as opposed to the SS and GE. The OCT parameters differed among the 4 groups on the basis of the distinct optic disc appearance and initial glaucomatous damage pattern. Clinicians should be aware that the diagnostic capability of OCT parameters could differ according to the type of optic disc damage in early glaucoma. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Koh, Victor; Tan, Colin; Tan, Pei Ting; Tan, Marcus; Balla, Vinay; Nah, Gerard; Cheng, Ching-Yu; Ohno-Matsui, Kyoko; Tan, Mellisa M H; Yang, Adeline; Zhao, Paul; Wong, Tien Yin; Saw, Seang-Mei
2016-04-01
To determine the prevalence and risk factors of myopic maculopathy and specific optic disc and macular changes in highly myopic eyes of young Asian adults and their impact on visual acuity. Prospective cross-sectional study. In total, 593 highly myopic (spherical equivalent refraction [SER] less than -6.00 diopters [D]) and 156 emmetropic (SER between -1.00 and +1.00 D) male participants from a population-based survey were included. All participants underwent standardized medical interviews, ophthalmic examination, and color fundus photographs. These photographs were graded systematically to determine the presence of optic disc and macular lesions. Myopic maculopathy was classified based on the International Classification of Myopic Maculopathy. The mean age was 21.1 ± 1.2 years. The mean SER for the highly myopic and emmetropic group was -8.87 ± 2.11 D and 0.40 ± 0.39 D, respectively (P < .001). Compared to emmetropic eyes, highly myopic eyes were significantly more likely to have optic disc tilt, peripapillary atrophy (PPA), posterior staphyloma, chorioretinal atrophy, and myopic maculopathy (all P < .001). The main findings included PPA (98.3%), disc tilt (22.0%), posterior staphyloma (32.0%), and chorioretinal atrophy (8.3%). Myopic maculopathy was present in 8.3% of highly myopic eyes and was associated with older age (odds ratio [OR] 1.66; 95% CI: 1.22, 2.26), reduced choroidal thickness (OR 0.99; 95% CI: 0.98, 0.99), and increased axial length (AL) (OR 1.52; 95% CI: 1.06, 2.19). The presence of disc tilt, posterior staphyloma, and chorioretinal atrophy were associated with reduced visual acuity. Our study showed that myopia-related changes of the optic disc and macula were common in highly myopic eyes even at a young age. The risk factors for myopic maculopathy include increased age, longer AL, and reduced choroidal thickness. Some of these changes were associated with reduced central visual function. Copyright © 2016 Elsevier Inc. All rights reserved.
The Role of Heparan Sulfate Proteoglycans in Optic Disc and Stalk Morphogenesis
Cai, Zhigang; Grobe, Kay; Zhang, Xin
2014-01-01
Background Heparan sulfate proteoglycans (HSPG) are important for embryonic development via the regulation of gradient formation and signaling of multiple growth factors and morphogens. Previous studies have shown that Bmp/Shh/Fgf signaling are required for the regionalization of the optic vesicle (OV) and for the closure of the optic fissure (OF), the disturbance of which underlie ocular anomalies such as microphthalmia, coloboma and optic nerve hypoplasia. Results To study HSPG-dependent coordination of these signaling pathways during mammalian visual system development, we have generated a series of OV-specific mutations in the heparan sulfate (HS) N-sulfotransferase genes (Ndst1 and Ndst2) and HS O-sulfotransferase genes (Hs2st, Hs6st1 and Hs6st2) in mice. Interestingly, the resulting HS undersulfation still allowed for normal retinal neurogenesis and optic fissure closure, but led to defective optic disc and stalk development. The adult mutant animals further developed optic nerve aplasia/hypoplasia and displayed retinal degeneration. We observed that MAPK/ERK signaling was down-regulated in Ndst mutants, and consistent with this, HS-related optic nerve morphogenesis defects in mutant mice could partially be rescued by constitutive Kras activation. Conclusions These results suggest that HSPGs, depending on their HS sulfation pattern, regulate multiple signaling pathways in optic disc and stalk morphogenesis. PMID:24753163
[Flicker comparison of optic disc photographs: sensitivity and specificity].
Funk, Jens; Lagrèze, Wolf; Zeyen, Thierry
2002-12-01
Examination and documentation of the optic nerve head are essential in monitoring glaucoma patients. Even minor changes in optic nerve head morphology can be visualised using the so-called flicker test: Two optic nerve head photographs, taken at consecutive examinations, are superimposed by projection. When occluding the pictures in a rapid alternating fashion, changes in optic nerve head morphology appear as motion. In this study, we evaluated sensitivity and specificity of the flicker test. A set of 33 pairs of serial optic disc slides was used as gold standard. These 33 pairs had been classified earlier by 3 independent groups of experts. 23 had been classified as "no change over time", 10 had been classified as "change". All 33 pairs were now evaluated by flicker comparison in a masked fashion. Flicker comparison usually took 1 minute per pair of slides. Sensitivity was 90 %, specificity was 65 %. The sensitivity was reasonably high. The moderate specificity was due to some cases showing "change" with the flicker comparison which might have been overlooked by the expert groups. Flicker comparison is an easy, fast and reliable technique to evaluate pairs of consecutive optic disc photographs.
Chen, Teresa C.
2009-01-01
Purpose: To demonstrate that video-rate spectral domain optical coherence tomography (SDOCT) can qualitatively and quantitatively evaluate optic nerve head (ONH) and retinal nerve fiber layer (RNFL) glaucomatous structural changes. To correlate quantitative SDOCT parameters with disc photography and visual fields. Methods: SDOCT images from 4 glaucoma eyes (4 patients) with varying stages of open-angle glaucoma (ie, early, moderate, late) were qualitatively contrasted with 2 age-matched normal eyes (2 patients). Of 61 other consecutive patients recruited in an institutional setting, 53 eyes (33 patients) met inclusion/exclusion criteria for quantitative studies. Images were obtained using two experimental SDOCT systems, one utilizing a superluminescent diode and the other a titanium:sapphire laser source, with axial resolutions of about 6 μm and 3 μm, respectively. Results: Classic glaucomatous ONH and RNFL structural changes were seen in SDOCT images. An SDOCT reference plane 139 μm above the retinal pigment epithelium yielded cup-disc ratios that best correlated with masked physician disc photography cup-disc ratio assessments. The minimum distance band, a novel SDOCT neuroretinal rim parameter, showed good correlation with physician cup-disc ratio assessments, visual field mean deviation, and pattern standard deviation (P values range, .0003–.024). RNFL and retinal thickness maps correlated well with disc photography and visual field testing. Conclusions: To our knowledge, this thesis presents the first comprehensive qualitative and quantitative evaluation of SDOCT images of the ONH and RNFL in glaucoma. This pilot study provides basis for developing more automated quantitative SDOCT-specific glaucoma algorithms needed for future prospective multicenter national trials. PMID:20126502
Automated detection of kinks from blood vessels for optic cup segmentation in retinal images
NASA Astrophysics Data System (ADS)
Wong, D. W. K.; Liu, J.; Lim, J. H.; Li, H.; Wong, T. Y.
2009-02-01
The accurate localization of the optic cup in retinal images is important to assess the cup to disc ratio (CDR) for glaucoma screening and management. Glaucoma is physiologically assessed by the increased excavation of the optic cup within the optic nerve head, also known as the optic disc. The CDR is thus an important indicator of risk and severity of glaucoma. In this paper, we propose a method of determining the cup boundary using non-stereographic retinal images by the automatic detection of a morphological feature within the optic disc known as kinks. Kinks are defined as the bendings of small vessels as they traverse from the disc to the cup, providing physiological validation for the cup boundary. To detect kinks, localized patches are first generated from a preliminary cup boundary obtained via level set. Features obtained using edge detection and wavelet transform are combined using a statistical approach rule to identify likely vessel edges. The kinks are then obtained automatically by analyzing the detected vessel edges for angular changes, and these kinks are subsequently used to obtain the cup boundary. A set of retinal images from the Singapore Eye Research Institute was obtained to assess the performance of the method, with each image being clinically graded for the CDR. From experiments, when kinks were used, the error on the CDR was reduced to less than 0.1 CDR units relative to the clinical CDR, which is within the intra-observer variability of 0.2 CDR units.
Han, Sangyoun; Jung, Jong Jin; Kim, Ungsoo Samuel
2015-12-01
To investigate the differences in retinal nerve fiber layer (RNFL) change and optic nerve head parameters between non-arteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal visual field defect. Seventeen NAION patients and 26 OAG patients were enrolled prospectively. The standard visual field indices (mean deviation, pattern standard deviation) were obtained from the Humphrey visual field test and differences between the two groups were analyzed. Cirrus HD-OCT parameters were used, including optic disc head analysis, average RNFL thickness, and RNFL thickness of each quadrant. The mean deviation and pattern standard deviation were not significantly different between the groups. In the affected eye, although the disc area was similar between the two groups (2.00 ± 0.32 and 1.99 ± 0.33 mm(2), p = 0.586), the rim area of the OAG group was smaller than that of the NAION group (1.26 ± 0.56 and 0.61 ± 0.15 mm(2), respectively, p < 0.001). RNFL asymmetry was not different between the two groups (p = 0.265), but the inferior RNFL thickness of both the affected and unaffected eyes were less in the OAG group than in the NAION group. In the analysis of optic disc morphology, both affected and unaffected eyes showed significant differences between two groups. To differentiate NAION from OAG in eyes with altitudinal visual field defects, optic disc head analysis of not only the affected eye, but also the unaffected eye, by using spectral domain optical coherence tomography may be helpful.
Multiwavelength studies of the gas and dust disc of IRAS 04158+2805
NASA Astrophysics Data System (ADS)
Glauser, A. M.; Ménard, F.; Pinte, C.; Duchêne, G.; Güdel, M.; Monin, J.-L.; Padgett, D. L.
2008-07-01
We present a study of the circumstellar environment of IRAS 04158+2805 based on multi-wavelength observations and models. Images in the optical and near-infrared, a polarisation map in the optical, and mid-infrared spectra were obtained with VLT-FORS1, CFHT-IR, and Spitzer-IRS. Additionally we used an X-ray spectrum observed with Chandra. We interpret the observations in terms of a central star surrounded by an axisymmetric circumstellar disc, but without an envelope, to test the validity of this simple geometry. We estimate the structural properties of the disc and its gas and dust content. We modelled the dust disc with a 3D continuum radiative transfer code, MCFOST, based on a Monte-Carlo method that provides synthetic scattered light images and polarisation maps, as well as spectral energy distributions. We find that the disc images and spectral energy distribution narrowly constrain many of the disc model parameters, such as a total dust mass of 1.0-1.75×10-4 M_⊙ and an inclination of 62°-63°. The maximum grain size required to fit all available data is of the order of 1.6-2.8 μm although the upper end of this range is loosely constrained. The observed optical polarisation map is reproduced well by the same disc model, suggesting that the geometry we find is adequate and the optical properties are representative of the visible dust content. We compare the inferred dust column density to the gas column density derived from the X-ray spectrum and find a gas-to-dust ratio along the line of sight that is consistent with the ISM value. To our knowledge, this measurement is the first to directly compare dust and gas column densities in a protoplanetary disc. Based on observations obtained at the Canada-France-Hawaii Telescope (CFHT) which is operated by the National Research Council of Canada, the Institut National des Sciences de l'Univers of the Centre National de la Recherche Scientifique of France, and the University of Hawaii. Based also on data collected at ESO/VLT during observation program 68-C.0171.
Arnold, Anthony C.; Costa, Roberta M. S.; Dumitrascu, Oana M.
2013-01-01
Purpose: To identify the spectrum of clinical and fluorescein angiographic features of optic disc ischemia in patients younger than 50 years. Methods: This retrospective comparative case series from a university consultative neuro-ophthalmology practice consisted of two phases. The first compared 108 cases of nonarteritic anterior ischemic optic neuropathy in patients younger than 50 years (NAIONy) to a cohort of 108 cases in patients 50 years or older (NAIONo). Predisposing risk factors, fluorescein angiographic features, and clinical course were compared. In the second phase, 12 cases of diabetic papillopathy under age 50 were assessed by fluorescein angiographic criteria for evidence of optic disc ischemia and compared to patients with NAIONy. Results: NAIONy comprised 108 (12.7%) of 848 NAION cases reviewed. Chronic renal failure with dialysis and migraine were more common in NAIONy. Fellow eye involvement rate was significantly higher for NAIONy patients (46/108, 42.6%) than for NAIONo patients (32/108, 29.6%). Fluorescein angiographic features of ischemia were documented in 44 (81.5%) of 54 eyes studied. In one case, these features were documented in pre-NAION edema. Diabetic papillopathy demonstrated delayed filling consistent with ischemia in 7 of 10 (70.0%), without significant visual field loss. Conclusions: Ischemic optic neuropathy in patients younger than 50 years is not rare. Fellow eye involvement is more frequent in younger patients. Fluorescein angiography confirmation of impaired perfusion in multiple syndromes of optic neuropathy corroborates a spectrum of optic disc ischemia ranging from perfusion delay without visual loss to severely impaired perfusion and visual loss and incorporates optic neuropathies previously considered nonischemic. PMID:24167327
Influence of optic disc leakage on objective optic nerve head assessment in patients with uveitis.
Heinz, Carsten; Kogelboom, Katy; Heiligenhaus, Arnd
2016-02-01
Secondary glaucoma is a common complication in patients with uveitis. Heidelberg Retina Tomography (HRT) and retinal nerve fiber layer (RNFL) thickness on optical coherence tomography (OCT) are widely used for examining optic nerve head changes. We evaluated these parameters in patients with uveitis and secondary glaucoma and with inflammatory papillary leakage on fluorescein angiography. Prospective single-center analysis of patients with uveitis, evaluating the impact of optic disc leakage on objective optic disc imaging parameters. Overall, 96 eyes of 59 patients were included. Papillary leakage was found in 42 eyes (43.8 %), and secondary glaucoma was found in 41 eyes (42.7 %). Glaucoma and papillary leakage were present in 12 (29 %) eyes with leakage and in 29 (54 %) eyes without leakage (p = 0.023). Neuroretinal rim area (p = 0.004), rim volume on HRT (p = 0.004), and RNFL thickness on OCT (p = 0.0008) were significantly increased in eyes with papillary leakage, while RNFL on HRT was unchanged (p = 0.255). When only eyes with normal IOP were examined, all objective parameters on OCT and HRT were significantly increased, whereas in eyes with secondary glaucoma, there was only a trend in the same direction, which did not reach significance. A comparison of eyes with secondary glaucoma and optic disc leakage to normal eyes with no glaucoma or leakage revealed no difference in any of the parameters. The objective parameters of optic nerve head imaging tools are significantly influenced by papillary leakage. In patients with secondary glaucoma and papillary leakage, these techniques are unable to detect and monitor glaucomatous damage.
Are All Retinal Nerve Fiber Layer Defects on Optic Coherence Tomography Glaucomatous?
Gür Güngör, Sirel; Ahmet, Akman
2017-01-01
Objectives: In this study, we investigated the patients who were referred to our clinic with a prediagnosis of glaucoma based on retinal nerve fiber layer (RNFL) defects on optic coherence tomography (OCT) but were determined to have nonglaucomatous RNLF defects upon detailed examination. Materials and Methods: The ophthalmic examination notes, OCT images, Heidelberg retinal tomography (HRT) II and fundus photographs of 357 patients were retrospectively evaluated. Final diagnoses of these patients were investigated. Results: Of the 357 patients, 216 (60.5%) were diagnosed as open angle glaucoma, 33 (9.2%) as low-tension glaucoma, 39 (10.9%) as pre-perimetric glaucoma. The ophthalmic examinations of 14 patients (3.9%) were normal and there were no RNFL defects in OCT examinations after dilatation. In 39 patients (10.9%), the ophthalmic and optic disc examinations were completely normal and no etiologic factor explaining RNFL defects was found. Twenty-two eyes of 16 patients (4.5%) were included in this study (the mean age was 53.8±11.5 years; 9 men and 7 women). After detailed questioning of the medical history and systemic and neurologic examinations, a diagnosis of ischemic optic neuropathy was made in 11 eyes (10 patients) (2.8%), optic neuritis in 3 eyes (2 patients) (0.6%), optic disc drusen in 4 eyes (2 patients) (0.6%), pseudotumor cerebri in 2 eyes (1 patient) (0.3%), and cerebral palsy in 2 eyes (1 patient) (0.3%). Conclusion: Decrease in RNFL thickness on OCT images alone may be misleading in glaucoma examination. In cases where optic disc cupping is not evident, diagnosis should not be based on OCT RNFL examinations alone, and the patient’s medical history, detailed ophthalmic examination, OCT optic disc parameters, HRT, and visual field tests should all be carefully evaluated together. PMID:29109895
Kim, Ko Eun; Jeoung, Jin Wook; Park, Ki Ho; Kim, Dong Myung; Kim, Seok Hwan
2015-03-01
To investigate the rate and associated factors of false-positive diagnostic classification of ganglion cell analysis (GCA) and retinal nerve fiber layer (RNFL) maps, and characteristic false-positive patterns on optical coherence tomography (OCT) deviation maps. Prospective, cross-sectional study. A total of 104 healthy eyes of 104 normal participants. All participants underwent peripapillary and macular spectral-domain (Cirrus-HD, Carl Zeiss Meditec Inc, Dublin, CA) OCT scans. False-positive diagnostic classification was defined as yellow or red color-coded areas for GCA and RNFL maps. Univariate and multivariate logistic regression analyses were used to determine associated factors. Eyes with abnormal OCT deviation maps were categorized on the basis of the shape and location of abnormal color-coded area. Differences in clinical characteristics among the subgroups were compared. (1) The rate and associated factors of false-positive OCT maps; (2) patterns of false-positive, color-coded areas on the GCA deviation map and associated clinical characteristics. Of the 104 healthy eyes, 42 (40.4%) and 32 (30.8%) showed abnormal diagnostic classifications on any of the GCA and RNFL maps, respectively. Multivariate analysis revealed that false-positive GCA diagnostic classification was associated with longer axial length and larger fovea-disc angle, whereas longer axial length and smaller disc area were associated with abnormal RNFL maps. Eyes with abnormal GCA deviation map were categorized as group A (donut-shaped round area around the inner annulus), group B (island-like isolated area), and group C (diffuse, circular area with an irregular inner margin in either). The axial length showed a significant increasing trend from group A to C (P=0.001), and likewise, the refractive error was more myopic in group C than in groups A (P=0.015) and B (P=0.014). Group C had thinner average ganglion cell-inner plexiform layer thickness compared with other groups (group A=B>C, P=0.004). Abnormal OCT diagnostic classification should be interpreted with caution, especially in eyes with long axial lengths, large fovea-disc angles, and small optic discs. Our findings suggest that the characteristic patterns of OCT deviation map can provide useful clues to distinguish glaucomatous changes from false-positive findings. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Optic nerve lesion following neuroborreliosis: a case report.
Burkhard, C; Gleichmann, M; Wilhelm, H
2001-01-01
Neuroborreliosis may cause various neuro-ophthalmological complications. We describe a case with a bilateral optic neuropathy. A 58-year-old female developed facial paresis six weeks after an insect bite. One week later she developed bilateral optic disc swelling with haemorrhages and nerve fibre bundle defects in the lower visual field of the left eye. In CSF and serum, raised IgM and IgG titres to Borrelia burgdorferi were found. Systemic antibiotic treatment led to improvement of the vision and facial paresis, but not all visual field defects resolved, probably due to ischemic lesions of the optic disc. In optic nerve lesions due to neuroborreliosis it is difficult to distinguish between inflammatory and ischemic lesions. This patient demonstrated features of an ischemic optic nerve lesion.
Optic disc segmentation for glaucoma screening system using fundus images.
Almazroa, Ahmed; Sun, Weiwei; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan
2017-01-01
Segmenting the optic disc (OD) is an important and essential step in creating a frame of reference for diagnosing optic nerve head pathologies such as glaucoma. Therefore, a reliable OD segmentation technique is necessary for automatic screening of optic nerve head abnormalities. The main contribution of this paper is in presenting a novel OD segmentation algorithm based on applying a level set method on a localized OD image. To prevent the blood vessels from interfering with the level set process, an inpainting technique was applied. As well an important contribution was to involve the variations in opinions among the ophthalmologists in detecting the disc boundaries and diagnosing the glaucoma. Most of the previous studies were trained and tested based on only one opinion, which can be assumed to be biased for the ophthalmologist. In addition, the accuracy was calculated based on the number of images that coincided with the ophthalmologists' agreed-upon images, and not only on the overlapping images as in previous studies. The ultimate goal of this project is to develop an automated image processing system for glaucoma screening. The disc algorithm is evaluated using a new retinal fundus image dataset called RIGA (retinal images for glaucoma analysis). In the case of low-quality images, a double level set was applied, in which the first level set was considered to be localization for the OD. Five hundred and fifty images are used to test the algorithm accuracy as well as the agreement among the manual markings of six ophthalmologists. The accuracy of the algorithm in marking the optic disc area and centroid was 83.9%, and the best agreement was observed between the results of the algorithm and manual markings in 379 images.
NASA Astrophysics Data System (ADS)
Matcher, Stephen J.; Winlove, C. Peter; Gangnus, Sergei V.
2004-04-01
Polarization-sensitive optical coherence tomography (PS-OCT) is used to measure the birefringence properties of bovine intervertebral disc and equine flexor tendon. For equine tendon the birefringence Dgrn is (6.0 ± 0.2) × 10-3 at a wavelength of 1.3 µm. This is somewhat larger than the values reported for bovine tendon. The surface region of the annulus fibrosus of a freshly excised intact bovine intervertebral disc displays an identical value of birefringence, Dgrn = (6.0 ± 0.6) × 10-3 at 1.3 µm. The nucleus pulposus does not display birefringence, the measured apparent value of Dgrn = (0.39 ± 0.01) × 10-3 being indistinguishable from the effects of depolarization due to multiple scattering. A clear difference is found between the depth-resolved retardance of equine tendon and that of bovine intervertebral disc. This apparently relates to the lamellar structure of the latter tissue, in which the collagen fibre orientation alternates between successive lamellae. A semi-empirical model based on Jones calculus shows that the measurements are in reasonable agreement with previous optical and x-ray data. These results imply that PS-OCT could be a useful tool to study collagen organization within the intervertebral disc in vitro and possibly in vivo and its variation with applied load and disease.
Doped sesquioxide ceramic for eye-safe solid state laser materials
NASA Astrophysics Data System (ADS)
Kim, Woohong; Baker, Colin; Florea, Catalin; Frantz, Jesse; Villalobos, Guillermo; Shaw, Brandon; Bowman, Steve; O'Connor, Shawn; Sadowski, Bryan; Hunt, Michael; Aggalwar, Ishwar; Sanghera, Jasbinder
2013-03-01
In this paper, we present our recent results in the development of Ho3+ doped sesquioxides for eye-safe solid state lasers. We have synthesized optical quality Lu2O3 nanopowders doped with concentrations of 0.1, 1.0, 2.0, and 5% Ho3+. The powders were synthesized by a co-precipitation method beginning with nitrates of holmium and lutetium. The nanopowders were hot pressed into optical quality ceramic discs. The optical transmission of the ceramic discs is excellent, nearly approaching the theoretical limit. The optical, spectral and morphological properties as well as the lasing performance from highly transparent ceramics are presented.
Multimodal segmentation of optic disc and cup from stereo fundus and SD-OCT images
NASA Astrophysics Data System (ADS)
Miri, Mohammad Saleh; Lee, Kyungmoo; Niemeijer, Meindert; Abràmoff, Michael D.; Kwon, Young H.; Garvin, Mona K.
2013-03-01
Glaucoma is one of the major causes of blindness worldwide. One important structural parameter for the diagnosis and management of glaucoma is the cup-to-disc ratio (CDR), which tends to become larger as glaucoma progresses. While approaches exist for segmenting the optic disc and cup within fundus photographs, and more recently, within spectral-domain optical coherence tomography (SD-OCT) volumes, no approaches have been reported for the simultaneous segmentation of these structures within both modalities combined. In this work, a multimodal pixel-classification approach for the segmentation of the optic disc and cup within fundus photographs and SD-OCT volumes is presented. In particular, after segmentation of other important structures (such as the retinal layers and retinal blood vessels) and fundus-to-SD-OCT image registration, features are extracted from both modalities and a k-nearest-neighbor classification approach is used to classify each pixel as cup, rim, or background. The approach is evaluated on 70 multimodal image pairs from 35 subjects in a leave-10%-out fashion (by subject). A significant improvement in classification accuracy is obtained using the multimodal approach over that obtained from the corresponding unimodal approach (97.8% versus 95.2%; p < 0:05; paired t-test).
Chuman, Hideki; Sugimoto, Takako; Nao-I, Nobuhisa
2017-12-01
This study aimed to clarify the vasodilatory effect of L-arginine on isolated rabbit and human posterior ciliary arteries (PCAs) and to investigate changes in optic disc blood flow after an infusion of L-arginine in vivo. Vascular ring segments were mounted on a double myograph system. After obtaining maximal contraction following administration of high-K solution, L-arginine was administrated. Six volunteers received an intravenous drip infusion of 100 ml of L-arginine or saline. Changes in optic disc blood flow were measured by laser speckle flowgraphy. L-arginine relaxed high-K solution-induced contracted rabbit PCAs. Carboxy-PTIO (nitric oxide scavenger) and L-NAME (nitric oxide synthase inhibitor) inhibited L-arginine-induced relaxation in rabbit PCAs. After removal of the endothelium of the rabbit PCAs, L-arginine still relaxed rabbit PCAs. L-arginine relaxed human PCAs, despite the lack of nitric oxide production. In the L-arginine infusion group, the mean blur rate was significantly greater than that of the control group in vivo. L-arginine has both nitric oxide-dependent and independent vasodilatory effect on high K- induced contractions in isolated rabbit and human PCAs. L-arginine increased optic disc blood flow in vivo.
Nicolela, Marcelo T; Soares, Adael S; Carrillo, Monica M; Chauhan, Balwantray C; LeBlanc, Raymond P; Artes, Paul H
2006-05-01
To evaluate optic disc topography changes after intraocular pressure (IOP) modulation in patients with glaucoma. Twenty-three patients with glaucoma were studied. Three mean optic disc topography images were obtained with the Heidelberg Retina Tomograph II at baseline and weeks 1, 2, 4, and 8 (visits 1, 2, 3, 4, and 5, respectively). Topical medications were discontinued in the study eye after visit 1 and resumed after visit 4 but maintained in the contralateral control eye. Central corneal thickness was measured at the last visit. Topographic changes were determined by stereometric parameters (rim area and mean cup depth) and at discrete topographic locations using the Topographic Change Analysis program (from the Heidelberg Retina Tomograph II). In the study eyes, IOP increased significantly (5.4 mm Hg at visit 4; P<.001) after withdrawal of topical medications but returned to baseline levels after resuming medications; no statistically significant topographic changes, however, were observed. Moreover, no relationship between change in IOP and stereometric parameters was observed. Central corneal thickness was not associated with changes in optic disc topography induced by IOP modulation. In patients with glaucoma, significant but relatively moderate IOP increases and decreases on the order of 5 mm Hg did not appear to have an effect on optic disc topography.
Balducci, Nicole; Morara, Mariachiara; Veronese, Chiara; Barboni, Piero; Casadei, Nicoletta Lelli; Savini, Giacomo; Parisi, Vincenzo; Sadun, Alfredo A; Ciardella, Antonio
2017-11-01
The purpose of our study was to describe the feature of acute non-arteritic or arteritic anterior ischemic optic neuropathy (NA-AION and A-AION) using optical coherence tomography angiography (OCT-A) and to compare it with fluorescein angiography (FA) and indocyanine green angiography (ICGA). In this retrospective, observational case-control study four NA-AION patients and one A-AION patient were examined by FA, ICGA and OCT-A within 2 weeks from disease presentation. The characteristics of the images were analyzed. Optic nerve head (ONH) and radial peripapillary capillaries (RPC) vessel densities (VDs) were compared between NA-AION and controls. In two of four NA-AION cases and in the A-AION patient, OCT-A clearly identified the boundary of the ischemic area at the level of the optic nerve head, which was comparable to optic disc filling defects detected by FA. In the other two NA-AION cases, a generalized leakage from the disc was visible with FA, yet OCT-A still demonstrated sectorial peripapillary capillary network reduction. Both ONH and RPC VDs were reduced in NA-AION patients, when compared to controls. OCT-A was able to identify microvascular defects and VD reduction in cases of acute optic disc edema due to NA-AION and A-AION. OCT-A provides additional information in ischemic conditions of the optic nerve head.
Ishida, Masahiro; Ichikawa, Yoshikazu; Higashida, Rieko; Tsutsumi, Yorihisa; Ishikawa, Atsushi; Imamura, Yutaka
2014-05-01
To examine the retinal displacement following successful macular hole (MH) surgery with internal limiting membrane (ILM) peeling and gas tamponade, and to determine the correlation between the extent of displacement and the basal MH size. Retrospective, interventional, observational case series. The medical records of consecutive patients with an idiopathic MH that had undergone vitrectomy with ILM peeling and gas tamponade were studied. The distances between the optic disc and the intersection of 2 retinal vessels located nasal or temporal to the fovea were measured manually preoperatively (A), and 2 weeks and 1, 3, 6, and 12 months postoperatively (B), on the fundus autofluorescence or near-infrared images. The basal and minimum diameters of the MHs were measured in the spectral-domain optical coherence tomographic images. The correlations between the ratio of the retinal displacement (A - B/A) and basal diameters of the MHs were determined. Twenty-one eyes of 21 patients (9 men, mean age: 64.6 ± 8.4 years) were studied. Ten eyes (47.6%) had stage 2 MH, 9 eyes (42.9%) had stage 3 MH, and 2 eyes (9.5%) had stage 4 MH. The temporal retinal vessels were displaced 260.8 ± 145.8 μm toward the optic disc at 2 weeks postoperatively, which was significantly greater than the 91.1 ± 89.7 μm of the nasal retinal vessels (paired t test, P < .001). The ratio of retinal displacement in the temporal field at 2 weeks was significantly correlated with the basal diameter of the MH (Spearman's rank correlation coeffieient = -0.476, P = .033. The greater displacement of the temporal retina than the nasal retina toward the optic disc postoperatively suggests that the temporal retina is more flexible and can be retracted toward the optic disc during the MH closure. Copyright © 2014 Elsevier Inc. All rights reserved.
Abouammoh, Marwan A; Alsulaiman, Sulaiman M; Gupta, Vishali S; Mousa, Ahmed; Hirakata, Akito; Berrocal, Maria H; Chenworth, Megan; Chhablani, Jay; Oshima, Yusuke; AlZamil, Waseem M; Casella, Antonio Marcelo; Papa-Oliva, Gabriela; Banker, Alay S; Arevalo, J Fernando
2016-04-01
To compare the functional and anatomic outcomes of pars plana vitrectomy (PPV) with juxtapapillary laser photocoagulation (JLP) versus vitrectomy without JLP in optic disc pit maculopathy. This was a multicentre, retrospective study of 46 consecutive patients with optic disc pit maculopathy presenting at tertiary eye centres between 1992 and 2012. Indications for surgery included distorted or decreased vision. Surgical intervention included PPV, posterior vitreous detachment, with or without gas tamponade. Twenty-four patients received laser photocoagulation at the temporal edge of the optic disc pit (group A) and 22 patients had no laser (group B). Postoperative best-corrected visual acuity (BCVA) and optical coherence tomography findings were the main outcome measures. Mean follow-up was 44 months (range 12-98 months). BCVA in group A improved significantly from 0.7 logMAR (20/100) preoperatively to 0.5 logMAR (20/60) postoperatively (p=0.017). In group B, BCVA improved from 0.7 logMAR (20/100) preoperatively to 0.4 logMAR (20/40) postoperatively (p=0.014). The difference in final BCVA between groups was not statistically significant (p=0.693). The mean central macular thickness (CMT) in group A improved significantly from 750 μm preoperatively to 309 μm at last follow-up (p<0.0001). The mean CMT in group B improved from 616 μm preoperatively to 291 μm at last follow-up (p=0.028). The difference in final CMT between groups was not statistically significant (p=0.747). PPV with JLP for optic disc pit maculopathy had similar functional and anatomic outcomes compared with vitrectomy without JLP. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
A miniature fiber optic pressure sensor for intradiscal pressure measurements of rodents
NASA Astrophysics Data System (ADS)
Nesson, Silas; Yu, Miao; Hsieh, Adam H.
2007-04-01
Lower back pain continues to be a leading cause of disability in people of all ages, and has been associated with degenerative disc disease. It is well accepted that mechanical stress, among other factors, can play a role in the development of disc degeneration. Pressures generated in the intervertebral disc have been measured both in vivo and in vitro for humans and animals. However, thus far it has been difficult to measure pressure experimentally in rodent discs due to their small size. With the prevalent use of rodent tail disc models in mechanobiology, it is important to characterize the intradiscal pressures generated with externally applied stresses. In this paper, a miniature fiber optic Fabry-Perot interferometric pressure sensor with an outer diameter of 360 μm was developed to measure intradiscal pressures in rat caudal discs. A low coherence interferometer based optical system was used, which includes a broadband light source, a high-speed spectrometer, and a Fabry-Perot sensor. The sensor employs a capillary tube, a flexible, polymer diaphragm coated with titanium as a partial mirror, and a fiber tip as another mirror. The pressure induced deformation of the diaphragm results in a cavity length change of the Fabry-Perot interferometer which can be calculated from the wavelength shift of interference fringes. The sensor exhibited good linearity with small applied pressures. Our validation experiments show that owing to the small size, inserting the sensor does not disrupt the annulus fibrosus and will not alter intradiscal pressures generated. Measurements also demonstrate the feasibility of using this sensor to quantify external load intradiscal pressure relationships in small animal discs.
Subcutaneous electrode structure
NASA Technical Reports Server (NTRS)
Lund, G. F. (Inventor)
1980-01-01
A subcutaneous electrode structure suitable for a chronic implant and for taking a low noise electrocardiogram of an active animal, comprises a thin inflexible, smooth disc of stainless steel having a diameter as of 5 to 30 mm, which is sutured in place to the animal being monitored. The disc electrode includes a radially directed slot extending in from the periphery of the disc for approximately 1/3 of the diameter. Electrical connection is made to the disc by means of a flexible lead wire that extends longitudinally of the slot and is woven through apertures in the disc and held at the terminal end by means of a spot welded tab. Within the slot, an electrically insulative sleeve, such as silicone rubber, is placed over the wire. The wire with the sleeve mounted thereon is captured in the plane of the disc and within the slot by means of crimping tabs extending laterally of the slot and over the insulative wire. The marginal lip of the slot area is apertured and an electrically insulative potting material such as silicone rubber, is potted in place overlaying the wire slot region and through the apertures.
Carreras, Francisco Javier; Medina, Javier; Ruiz-Lozano, Mariola; Carreras, Ignacio; Castro, Juan Luis
2014-04-17
As part of a larger project on virtual tissue engineering of the optic pathways, we describe the conditions that guide axons extending from the retina to the optic nerve head and formulate algorithms that meet such conditions. To find the entrance site on the optic nerve head of each axon, we challenge the fibers to comply with current models of axonal pathfinding. First, we build a retinal map using a single type of retinal ganglion cell (RGC) using density functions from the literature. Dendritic arbors are equated to receptive fields. Shape and size of retinal surface and optic nerve head (ONH) are defined. A computer model relates each soma to the corresponding entry point of its axon into the optic disc. Weights are given to the heuristics that guide the preference entry order in the nerve. Retinal ganglion cells from the area centralis saturate the temporal section of the disc. Retinal ganglion cells temporal to the area centralis curve their paths surrounding the fovea; some of these cells enter the disc centrally rather than peripherally. Nasal regions of the disc receive mixed axons from the far periphery of the temporal hemiretina, together with axons from the nasal half. The model plots the course of the axon using Bezier curves and compares them with clinical data, for a coincidence level of 86% or higher. Our model is able to simulate basic data of the early optic pathways including certain singularities and to mimic mechanisms operating during development, such as timing and fasciculation. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
USDA-ARS?s Scientific Manuscript database
Immunolocalization of alpha2-, beta- and delta-giardin in Giardia showed that in the trophozoites and cysts delta-giardin it strictly associated with the ventral disc. Optical sectioning of the ventral discs, together with quantitative colocalization of the immunoreactivity for delta- and beta-giard...
NASA Astrophysics Data System (ADS)
Sobol, Emil; Sviridov, Alexander; Omeltchenko, Alexander; Baum, Olga; Baskov, Andrey; Borchshenko, Igor; Golubev, Vladimir; Baskov, Vladimir
2011-03-01
In 1999 we have introduced a new approach for treatment of spine diseases based on the mechanical effect of nondestructive laser radiation on the nucleus pulposus of the intervertebral disc. Laser reconstruction of spine discs (LRD) involves puncture of the disc and non-destructive laser irradiation of the nucleus pulposus to activate reparative processes in the disc tissues. In vivo animal study has shown that LRD allows activate the growth of hyaline type cartilage in laser affected zone. The paper considers physical processes and mechanisms of laser regeneration, presents results of investigations aimed to optimize laser settings and to develop feedback control system for laser reparation in cartilages of spine and joints. The results of laser reconstruction of intervertebral discs for 510 patients have shown substantial relief of back pain for 90% of patients. Laser technology has been experimentally tested for reparation of traumatic and degenerative diseases in joint cartilage of 20 minipigs. It is shown that laser regeneration of cartilage allows feeling large (more than 5 mm) defects which usually never repair on one's own. Optical techniques have been used to promote safety and efficacy of the laser procedures.
NASA Astrophysics Data System (ADS)
Sharma, Archie; Corona, Enrique; Mitra, Sunanda; Nutter, Brian S.
2006-03-01
Early detection of structural damage to the optic nerve head (ONH) is critical in diagnosis of glaucoma, because such glaucomatous damage precedes clinically identifiable visual loss. Early detection of glaucoma can prevent progression of the disease and consequent loss of vision. Traditional early detection techniques involve observing changes in the ONH through an ophthalmoscope. Stereo fundus photography is also routinely used to detect subtle changes in the ONH. However, clinical evaluation of stereo fundus photographs suffers from inter- and intra-subject variability. Even the Heidelberg Retina Tomograph (HRT) has not been found to be sufficiently sensitive for early detection. A semi-automated algorithm for quantitative representation of the optic disc and cup contours by computing accumulated disparities in the disc and cup regions from stereo fundus image pairs has already been developed using advanced digital image analysis methodologies. A 3-D visualization of the disc and cup is achieved assuming camera geometry. High correlation among computer-generated and manually segmented cup to disc ratios in a longitudinal study involving 159 stereo fundus image pairs has already been demonstrated. However, clinical usefulness of the proposed technique can only be tested by a fully automated algorithm. In this paper, we present a fully automated algorithm for segmentation of optic cup and disc contours from corresponding stereo disparity information. Because this technique does not involve human intervention, it eliminates subjective variability encountered in currently used clinical methods and provides ophthalmologists with a cost-effective and quantitative method for detection of ONH structural damage for early detection of glaucoma.
Challenges In Early Glaucoma Detection.
Dervisevic, Edita; Pavljasevic, Suzana; Dervisevic, Almir; Kasumovic, Sanja Sefic
2016-06-01
Glaucoma is the most common optic neuropathy which is characterized by progressive loss of retinal ganglion cells, the excavation of the optic nerve head, associated with defects in the visual field. It is not a disease, but the final result of united and yet completely unidentified cellular and subcellular processes and effects of many factors responsible for changes in retinal ganglion cells leading to their accelerated apoptosis. This is a prospective-retrospective, comparative, randomized clinical trial that included 150 patients, 97 were female and 53 male. The age of patients ranged from 18 to 80 years. The highest degree of myopia in category of tilted optic discs had patients with large disc (4.05 + -0.65). Values of the degree of myopia have linearly declined in relation to the size of the oblique disc. The analysis of the results revealed that the subjects who had a higher degree of myopia associated with glaucoma had frequent parapapillar atrophy of alpha and beta zones. The highest percentage of subjects with parapapillar changes were in the group of patients who had other than glaucoma and myopia (62%), then in the group of patients with glaucoma only (56%). Previous studies on the relationship between myopia and open-angle glaucoma are based on the results of observational studies. However, according to recent findings, based on the available studies, the systematic approach to estimate the association between myopia and glaucoma does not exist. Disc Damage Likelihood Scale (DDLS) is a new system for assessing glaucomatous damage of the optic disc which strongly correlates with the degree of visual field loss.
Automated Registration of Multimodal Optic Disc Images: Clinical Assessment of Alignment Accuracy.
Ng, Wai Siene; Legg, Phil; Avadhanam, Venkat; Aye, Kyaw; Evans, Steffan H P; North, Rachel V; Marshall, Andrew D; Rosin, Paul; Morgan, James E
2016-04-01
To determine the accuracy of automated alignment algorithms for the registration of optic disc images obtained by 2 different modalities: fundus photography and scanning laser tomography. Images obtained with the Heidelberg Retina Tomograph II and paired photographic optic disc images of 135 eyes were analyzed. Three state-of-the-art automated registration techniques Regional Mutual Information, rigid Feature Neighbourhood Mutual Information (FNMI), and nonrigid FNMI (NRFNMI) were used to align these image pairs. Alignment of each composite picture was assessed on a 5-point grading scale: "Fail" (no alignment of vessels with no vessel contact), "Weak" (vessels have slight contact), "Good" (vessels with <50% contact), "Very Good" (vessels with >50% contact), and "Excellent" (complete alignment). Custom software generated an image mosaic in which the modalities were interleaved as a series of alternate 5×5-pixel blocks. These were graded independently by 3 clinically experienced observers. A total of 810 image pairs were assessed. All 3 registration techniques achieved a score of "Good" or better in >95% of the image sets. NRFNMI had the highest percentage of "Excellent" (mean: 99.6%; range, 95.2% to 99.6%), followed by Regional Mutual Information (mean: 81.6%; range, 86.3% to 78.5%) and FNMI (mean: 73.1%; range, 85.2% to 54.4%). Automated registration of optic disc images by different modalities is a feasible option for clinical application. All 3 methods provided useful levels of alignment, but the NRFNMI technique consistently outperformed the others and is recommended as a practical approach to the automated registration of multimodal disc images.
Optic nerve head drusen and idiopathic intracranial hypertension in a 14-year-old girl.
Granger, Robert H; Bonnelame, Thomas; Daubenton, John; Dreyer, Michael; McCartney, Paul
2009-01-01
A 14-year-old girl had a 3-month history of headache and blurred vision. Funduscopy showed bilateral optic disc edema. Findings on brain imaging were normal, and a diagnosis of idiopathic intracranial hypertension was confirmed after lumbar puncture showed an elevated opening pressure of 32 cm H(2)O. Optic nerve head drusen were noted on computed tomography scan and confirmed with B-scan ultrasound. After 2 years, resolution of symptoms coincided with variable compliance to treatment with acetazolamide and concomitant papilledema. In general, optic disc edema poses a clinical conundrum due to the more common occurrence of optic nerve head drusen, potentially resulting in delayed diagnosis and treatment of idiopathic intracranial hypertension. Copyright 2009, SLACK Incorporated.
High-speed photometry of the eclipsing dwarf nova OY Carinae
NASA Technical Reports Server (NTRS)
Cook, M. C.
1985-01-01
High-speed photometry of the eclipsing dwarf nova OY Car in the quiescent state is presented. OY Car becomes highly reddened during eclipse, with minimum flux colours inconsistent with optically thick emission in the U and B bandpasses. Mass ratios in the range 6.5 to 12 are required to reconcile the eclipse structure with theoretical gas stream trajectories. Primary eclipse timings reveal a significant decrease in the orbital period and the duration of primary eclipse indicates the presence of a luminous ring about the white dwarf. The hotspot eclipse reveals a hotspot which is elongated along the rim of the accretion disc, with optical emission being non-uniformly distributed along the rim. The location of the hotspot in the accretion disc implies a disc radius larger than that of an inviscid disc, with variation in the position of the hotspot being consistent with a fixed stream trajectory.
Karnowski, Thomas P [Knoxville, TN; Tobin, Jr., Kenneth W.; Muthusamy Govindasamy, Vijaya Priya [Knoxville, TN; Chaum, Edward [Memphis, TN
2012-07-10
A method for assigning a confidence metric for automated determination of optic disc location that includes analyzing a retinal image and determining at least two sets of coordinates locating an optic disc in the retinal image. The sets of coordinates can be determined using first and second image analysis techniques that are different from one another. An accuracy parameter can be calculated and compared to a primary risk cut-off value. A high confidence level can be assigned to the retinal image if the accuracy parameter is less than the primary risk cut-off value and a low confidence level can be assigned to the retinal image if the accuracy parameter is greater than the primary risk cut-off value. The primary risk cut-off value being selected to represent an acceptable risk of misdiagnosis of a disease having retinal manifestations by the automated technique.
Oscillations of Static Discs around Schwarzschild Black Holes: Effect of Self-Gravitation
NASA Astrophysics Data System (ADS)
Semerák, Oldřich; Žáček, Miroslav
2000-12-01
The oscillations of accretion-disc matter about roughly circular motion may produce a quasi-periodic variation in the observed signal (Ipser 1996, AAA 65.067.047). They were studied theoretically on non-gravitating, test discs, in a pseudo-Newtonian manner as well as in general relativity, both in static and in stationary fields. The present paper shows how the radial profiles of oscillation frequencies can be modified by the self-gravity of the disc. Exact superpositions of a Schwarzschild black hole with the Lemos and Letelier (1994, AAA 61.067.077) annular discs (static thin discs obtained by inversion of the first Morgan-Morgan solution) are considered to be simple (static) models of an accretion system. Both the epicyclic and perpendicular frequencies are plotted against the Schwarzschild radius, the circumferential radius, and the proper distance from the horizon. The curves indicate that in the innermost parts more massive discs are more stable with respect to horizontal perturbations, whereas they are less stable with respect to vertical perturbations. In the case of a sequence of discs interpretable as counter-rotating particles on stable time-like circular geodesics and having their inner rims just on marginally stable circular orbits, oscillations of the inner parts get faster with increasing disc mass; the maximum of the epicyclic frequency, important for trapping of the low-frequency modes near the inner radius, moves to smaller radii and becomes somewhat higher.
Dias, Diego Torres; Ushida, Michele; Battistella, Roberto; Dorairaj, Syril; Prata, Tiago Santos
2017-01-10
To analyze the most common neurophthalmological conditions that may mimic glaucomatous optic neuropathy and to determine which most often lead to misdiagnosis when evaluated by a glaucoma specialist. We reviewed the charts of consecutive patients with optic neuropathies caused by neurophthalmological conditions screened in a single Eye Clinic within a period of 24 months. Within these enrolled patients, we selected the eyes whose fundoscopic appearance could resemble glaucoma based in pre-defined criteria (vertical cup-to-disc ratio ≥0.6, asymmetry of the cup-to-disc ratio ≥0.2 between eyes, presence of localized retinal nerve fiber layer and/or neuroretinal rim defects, and disc haemorrhages). Then, color fundus photographs and Humphrey Visual Field tests (HVF) of these eyes were mixed with tests from 21 consecutive glaucomatous patients (42 eyes with normal tension glaucoma). These images were mixed randomly and a masked glaucoma specialist was asked to distinguish if each set of exams was from a patient with glaucoma or with a neurophthalmologic condition. Among the 101 eyes (68 patients) enrolled with neurophthalmological diseases, 16 (15.8%) were classified as conditions that could mimic glaucoma. The most common diagnoses were ischemic optic neuropathy (25%), compressive optic neuropathy (18.7%) and hereditary optic neuropathy (18.7%). Based on the analysis of fundus photographs and HVF tests, 25% of these were misdiagnosed as glaucoma (two ischemic optic neuropathies and two congenital optic disc anomalies). Conversely, 11.9% of the glaucomatous neuropathies were misdiagnosed as neurophthalmological disorders. Overall, the glaucoma specialist correctly diagnosed 84.5% of the eyes. Some neurophthalmological disorders can mimic glaucoma. In our study, isquemic and compressive optic neuropathies were the ones that most often did so. Almost one quarter of the eyes were misdiagnosed when evaluated by a glaucoma specialist, which can lead to inadequate management and influence the prognosis of these patients.
Equilibrium star formation in a constant Q disc: model optimization and initial tests
NASA Astrophysics Data System (ADS)
Zheng, Zheng; Meurer, Gerhardt R.; Heckman, Timothy M.; Thilker, David A.; Zwaan, Martin A.
2013-10-01
We develop a model for the distribution of the interstellar medium (ISM) and star formation in galaxies based on recent studies that indicate that galactic discs stabilize to a constant stability parameter, which we combine with prescriptions of how the phases of the ISM are determined and for the star formation law (SFL). The model predicts the gas surface mass density and star formation intensity of a galaxy given its rotation curve, stellar surface mass density and the gas velocity dispersion. This model is tested on radial profiles of neutral and molecular ISM surface mass density and star formation intensity of 12 galaxies selected from the H I Nearby Galaxy Survey sample. Our tests focus on intermediate radii (0.3 to 1 times the optical radius) because there are insufficient data to test the outer discs and the fits are less accurate in detail in the centre. Nevertheless, the model produces reasonable agreement with the ISM mass and star formation rate integrated over the central region in all but one case. To optimize the model, we evaluate four recipes for the stability parameter, three recipes for apportioning the ISM into molecular and neutral components, and eight versions of the SFL. We find no clear-cut best prescription for the two-fluid (gas and stars) stability parameter Q2f and therefore for simplicity, we use the Wang and Silk approximation (QWS). We found that an empirical scaling between the molecular-to-neutral ISM ratio (Rmol) and the stellar surface mass density proposed by Leroy et al. works marginally better than the other two prescriptions for this ratio in predicting the ISM profiles, and noticeably better in predicting the star formation intensity from the ISM profiles produced by our model with the SFLs we tested. Thus, in the context of our modelled ISM profiles, the linear molecular SFL and the two-component SFL work better than the other prescriptions we tested. We incorporate these relations into our `constant Q disc' model.
Holló, Gábor
2015-12-01
In addition to retinal nerve fiber layer thickness measurements, the recently introduced AngioVue optical coherence tomography (OCT) offers corresponding layer-by-layer Doppler OCT and en face OCT functions, for simultaneous evaluation of perfusion and structure of the optic nerve head. We investigated the clinical usefulness of combined use of Doppler and en face Fourier-domain OCT functions of the AngioVue Fourier-domain OCT for discrimination of a disc hemorrhage and a disc hemorrhage-like atypical vessel structure located deep in the lamina cribrosa. We present our findings with AngioVue OCT on a disc hemorrhage and a spatially related retinal nerve fiber layer bundle defect in a glaucomatous eye (case 1). Both alterations were detected on en face OCT images without any Doppler OCT signal. We also report on an aneurysm suggestive for a disc hemorrhage on clinical examination and disc photography in a treated ocular hypertensive eye (case 2). The aneurysm was within the lamina cribrosa tissue at the border of the cup and the neuroretinal rim. This vascular structure produced strong Doppler signals but no structurally detectable signs on the en face OCT images. Combined evaluation of corresponding Doppler OCT and en face OCT images enables ophthalmologists to easily separate true disc hemorrhages from disc hemorrhage-like deep vascular structures. This is of clinical significance in preventing unnecessary intensification of pressure-lowering treatment in glaucoma.
Submandibular approach to the C2-3 disc level: microsurgical anatomy with clinical application.
Russo, Antonino; Albanese, Erminia; Quiroga, Monica; Ulm, Arthur J
2009-04-01
Approaching the C2-3 disc level is challenging because of its location behind the mandible and the vital neurovascular structures overlying the area. The purpose of this study was to illustrate in a stepwise fashion the microsurgical anatomy of the submandibular approach to the C2-3 disc. Ten adult formalin-fixed cadaveric specimens (20 sides) were studied. Particular attention was paid to the structures limiting the exposure. The authors measured the distance between the inferior border of the mandible and the marginal mandibular branch of the facial nerve running inferior to the mandible, the distance between the horizontal segment of the hypoglossal nerve and the hyoid bone, and the distance between the horizontal segment of the hypoglossal nerve and the mandible. They compared the location of the superior laryngeal nerve with regard to the submandibular and the standard Smith-Robinson approaches. A clinical case illustrating the usefulness of the surgical technique in this region is presented. The mean distance between the inferior border of the mandible and the lowest point of the marginal mandibular branch of the facial nerve was 6.7 +/- 1.69 mm. The hypoglossal nerve's mean distance above the hyoid bone was 8.4 +/- 1.78 mm and below the mandible was 19.6 +/- 6.39 mm. The internal branch of the superior laryngeal nerve, with respect to the cervical spine, always entered the thyrohyoid membrane just inferior to the C-3 vertebral body. The superior laryngeal nerve was found to be an impediment to approaching the C2-3 disc through the standard Smith-Robinson approach. The submandibular approach provides excellent exposure, with a perpendicular view of the C2-3 disc level. This approach is one of the options to be considered when dealing with high cervical pathologies.
Chauhan, Balwantray C; Nicolela, Marcelo T; Artes, Paul H
2009-11-01
To determine whether glaucoma patients with progressive optic disc change have subsequent visual field progression earlier and at a faster rate compared with those without disc change. Prospective, longitudinal, cohort study. Eighty-one patients with open-angle glaucoma. Patients underwent confocal scanning laser tomography and standard automated perimetry every 6 months. The complete follow-up was divided into initial and subsequent periods. Two initial periods-first 3 years (Protocol A) and first half of the total follow-up (Protocol B)-were used, with the respective remainder being the subsequent follow-up. Disc change during the initial follow-up was determined with liberal, moderate, or conservative criteria of the Topographic Change Analysis. Subsequent field progression was determined with significant pattern deviation change in >or=3 locations (criterion used in the Early Manifest Glaucoma Trial). As a control analysis, field change during the initial follow-up was determined with significant pattern deviation change in >or=1, >or=2, or >or=3 locations. Survival time to subsequent field progression, rates of mean deviation (MD) change, and positive and negative likelihood ratios. The median (interquartile range) total follow-up was 11.0 (8.0-12.0) years with 22 (18-24) examinations. More patients had disc changes during the initial follow-up compared with field changes. The mean time to field progression was consistently shorter (protocol A, 0.8-1.7 years; protocol B, 0.3-0.7 years) in patients with prior disc change. In the control analysis, patients with prior field change had statistically earlier subsequent field progression (protocol A, 2.9-3.0 years; protocol B, 0.7-0.9). Similarly, patients with either prior disc or field change always had worse mean rates of subsequent MD change, although the distributions overlapped widely. Patients with subsequent field progression were up to 3 times more likely to have prior disc change compared with those without, and up to 5 times more likely to have prior field change compared with those without. Longitudinally measured optic disc change is predictive of subsequent visual field progression and may be an efficacious end point for functional outcomes in clinical studies and trials in glaucoma.
Schiffbauer, James D; Yin, Leiming; Bodnar, Robert J; Kaufman, Alan J; Meng, Fanwei; Hu, Jie; Shen, Bing; Yuan, Xunlai; Bao, Huiming; Xiao, Shuhai
2007-08-01
Abundant graphite particles occur in amphibolite-grade quartzite of the Archean-Paleoproterozoic Wutai Metamorphic Complex in the Wutaishan area of North China. Petrographic thin section observations suggest that the graphite particles occur within and between quartzite clasts and are heterogeneous in origin. Using HF maceration techniques, the Wutai graphite particles were extracted for further investigation. Laser Raman spectroscopic analysis of a population of extracted graphite discs indicated that they experienced a maximum metamorphic temperature of 513 +/- 50 degrees C, which is consistent with the metamorphic grade of the host rock and supports their indigenicity. Scanning and transmission electron microscopy revealed that the particles bear morphological features (such as hexagonal sheets of graphite crystals) related to metamorphism and crystal growth, but a small fraction of them (graphite discs) are characterized by a circular morphology, distinct marginal concentric folds, surficial wrinkles, and complex nanostructures. Ion microprobe analysis of individual graphite discs showed that their carbon isotope compositions range from -7.4 per thousand to -35.9 per thousand V-PDB (Vienna Pee Dee Belemnite), with an average of -20.3 per thousand, which is comparable to bulk analysis of extracted carbonaceous material. The range of their size, ultrastructures, and isotopic signatures suggests that the morphology and geochemistry of the Wutai graphite discs were overprinted by metamorphism and their ultimate carbon source probably had diverse origins that included abiotic processes. We considered both biotic and abiotic origins of the carbon source and graphite disc morphologies and cannot falsify the possibility that some circular graphite discs characterized by marginal folds and surficial wrinkles represent deflated, compressed, and subsequently graphitized organic-walled vesicles. Together with reports by other authors of acanthomorphic acritarchs from greenschist-amphibolite-grade metamorphic rocks, this study suggests that it is worthwhile to examine carbonaceous materials preserved in highly metamorphosed rocks for possible evidence of ancient life.
NASA Astrophysics Data System (ADS)
Reyes, R.; Mandelbaum, R.; Gunn, J. E.; Nakajima, R.; Seljak, U.; Hirata, C. M.
2012-10-01
In this paper, we measure the optical-to-virial velocity ratios Vopt/V200c of disc galaxies in the Sloan Digital Sky Survey (SDSS) at a mean redshift of
Relationship Between Anterior Lamina Cribrosa Surface Tilt and Glaucoma Development in Myopic Eyes.
Lee, Eun Jung; Han, Jong Chul; Kee, Changwon
2017-05-01
To evaluate the anterior lamina cribrosa (LC) surface tilt angle in myopic eyes and associate it with glaucoma development. In this retrospective study, medical records of myopic patients referred for glaucoma examination from July 1, 2012 to March 30, 2016 were reviewed. Comprehensive ophthalmic examination including spectral-domain optical coherence tomography were performed. We measured the angle of anterior LC surface tilt against Bruch's membrane opening from optical coherence tomography images at the center of the clinical optic disc margin. In horizontal and vertical sections, the angles were defined as α and β, respectively. Patients were grouped according to the presence of glaucomatous damage and factors including optic nerve head morphologic parameters and LC tilt angles were compared between the 2 groups. Among 138 patients originally enrolled, 102 patients were finally analyzed. One eye from 1 patient was randomly chosen. Fifty-five eyes had glaucoma and 47 were normal. The degree of myopia and all optic nerve head morphologic parameters were not significantly different between the 2 groups. However, |α| and |β| were significantly larger in the glaucoma group (all P<0.001), and significances were maintained in multivariate analysis (P<0.001). Larger anterior LC surface tilt angles were related to the presence of glaucoma in normal-pressure myopic eyes. Angulation of the LC against Bruch's membrane opening plane might be associated with increased glaucoma susceptibility in myopic eyes. Further investigations are warranted before clinical utilization of LC tilt as glaucoma susceptibility biomarker.
NASA Astrophysics Data System (ADS)
Muramatsu, Chisako; Nakagawa, Toshiaki; Sawada, Akira; Hatanaka, Yuji; Hara, Takeshi; Yamamoto, Tetsuya; Fujita, Hiroshi
2009-02-01
A large cup-to-disc (C/D) ratio, which is the ratio of the diameter of the depression (cup) to that of the optical nerve head (ONH, disc), can be one of the important signs for diagnosis of glaucoma. Eighty eyes, including 25 eyes with the signs of glaucoma, were imaged by a stereo retinal fundus camera. An ophthalmologist provided the outlines of cup and disc on a regular monitor and on the stereo display. The depth image of the ONH was created by determining the corresponding pixels in a pair of images based on the correlation coefficient in localized regions. The areas of the disc and cup were determined by use of the red component in one of the color images and by use of the depth image, respectively. The C/D ratio was determined based on the largest vertical lengths in the cup and disc areas, which was then compared with that by the ophthalmologist. The disc areas determined by the computerized method agreed relatively well with those determined by the ophthalmologist, whereas the agreement for the cup areas was somewhat lower. When C/D ratios were employed for distinction between the glaucomatous and non-glaucomatous eyes, the area under the receiver operating characteristic curve (AUC) was 0.83. The computerized analysis of ONH can be useful for diagnosis of glaucoma.
Gili, Pablo; Flores-Rodríguez, Patricia; Yangüela, Julio; Orduña-Azcona, Javier; Martín-Ríos, María Dolores
2013-03-01
Evaluation of the efficacy of monochromatic photography of the ocular fundus in differentiating optic nerve head drusen (ONHD) and optic disc oedema (ODE). Sixty-six patients with ONHD, 31 patients with ODE and 70 healthy subjects were studied. Colour and monochromatic fundus photography with different filters (green, red and autofluorescence) were performed. The results were analysed blindly by two observers. The sensitivity, specificity and interobserver agreement (k) of each test were assessed. Colour photography offers 65.5 % sensitivity and 100 % specificity for the diagnosis of ONHD. Monochromatic photography improves sensitivity and specificity and provides similar results: green filter (71.20 % sensitivity, 96.70 % specificity), red filter (80.30 % sensitivity, 96.80 % specificity), and autofluorescence technique (87.8 % sensitivity, 100 % specificity). The interobserver agreement was good with all techniques used: autofluorescence (k = 0.957), green filter (k = 0.897), red filter (k = 0.818) and colour (k = 0.809). Monochromatic fundus photography permits ONHD and ODE to be differentiated, with good sensitivity and very high specificity. The best results were obtained with autofluorescence and red filter study.
NASA Astrophysics Data System (ADS)
Burkhardt, Anke; Geissler, Stefan; Cimalla, Peter; Walther, Julia; Koch, Edmund
2010-02-01
Reason for using optical coherence tomography (OCT) to locate the germinal disc is the questionable and ethically alarming killing of male layer chickens because for the layer line only the females are necessary. To avoid this and to protect the animal rights, the sex of the fertilized chicken egg has to be determined as early as possible in the unincubated state. Because the information whether the chick becomes male or female can be found in the germinal disc an accurate localization for sexing is essential. The germinal disc is located somewhere on top of the yolk and has a diameter of approximately 4 - 5 mm. Different imaging methods like ultrasonography, 3D-X-ray micro computed tomography and magnetic resonance imaging were used for localization until now, but found to be impractical. The goal of this study is to prove if OCT can be a moderate approach for the precise in ovo localization. Because the eggshell is an impenetrable barrier for OCT and to minimize the penetration of germs a very small hole is placed in the eggshell and a fan-shaped optical scanning pattern is used.
Iutaka, Natalia A; Grochowski, Rubens A; Kasahara, Niro
2017-01-01
To evaluate the correlation between visual field index (VFI) and both structural and functional measures of the optic disc in primary open angle glaucoma patients and suspects. In this retrospective study, 162 glaucoma patients and suspects underwent standard automated perimetry (SAP), retinography, and retinal nerve fiber layer (RNFL) measurement. The optic disc was stratified according to the vertical cup/disc ratio (C/D) and sorted by the disc damage likelihood scale (DDLS). RNFL was measured with the optical coherence tomography. The VFI perimetry was correlated with the mean deviation (MD) and pattern standard deviation (PSD) obtained by SAP, and structural parameters by Pearson's correlation coefficients. VFI displayed strong correlation with MD ( R = 0.959) and PSD ( R = -0.744). The linear correlations between VFI and structural measures including C/D ( R = -0.179, P = 0.012), DDLS ( R = -0.214, P = 0.006), and RNFL ( R = 0.416, P < 0.001) were weak but statistically significant. VFI showed a strong correlation with MD and PSD but demonstrated a weak correlation with structural measures. It can possibly be used as a marker for functional impairment severity in patients with glaucoma.
Absolute angular encoder based on optical diffraction
NASA Astrophysics Data System (ADS)
Wu, Jian; Zhou, Tingting; Yuan, Bo; Wang, Liqiang
2015-08-01
A new encoding method for absolute angular encoder based on optical diffraction was proposed in the present study. In this method, an encoder disc is specially designed that a series of elements are uniformly spaced in one circle and each element is consisted of four diffraction gratings, which are tilted in the directions of 30°, 60°, -60° and -30°, respectively. The disc is illuminated by a coherent light and the diffractive signals are received. The positions of diffractive spots are used for absolute encoding and their intensities are for subdivision, which is different from the traditional optical encoder based on transparent/opaque binary principle. Since the track's width in the disc is not limited in the diffraction pattern, it provides a new way to solve the contradiction between the size and resolution, which is good for minimization of encoder. According to the proposed principle, the diffraction pattern disc with a diameter of 40 mm was made by lithography in the glass substrate. A prototype of absolute angular encoder with a resolution of 20" was built up. Its maximum error was tested as 78" by comparing with a small angle measuring system based on laser beam deflection.
NASA Astrophysics Data System (ADS)
Ueno, Yoshiyasu; Nakamoto, Ryouichi; Sakaguchi, Jun; Suzuki, Rei
2006-12-01
In frequency ranges above 200-300 GHz, the second slowest relaxation in the optical response (such as carrier-cooling relaxation having a time constant of 1-2 ps) of a semiconductor optical amplifier inside the conventional delayed-interference signal-wavelength converter (DISC) scheme is thought to start the distortion of all-optically gated waveforms. In this work, we design a digital optical-spectrum-synthesizer block that is part of the expanded DISC scheme. Our numerically calculated spectra, waveforms, and eye diagrams with assumed pseudorandom digital data pulses indicate that this synthesizer significantly removes strong distortion from the gated waveforms. A signal-to-noise ratio of 20 dB was obtained from our random-data eye diagram, providing proof of effectiveness in principle.
ERIC Educational Resources Information Center
Wilson, Kathleen S.; Tally, William J.
This report describes the Palenque Project, a highly interactive, multimedia, optical disc research prototype which was developed for home use and tested by observing 25 children in the 9 to 14 year age range and their families and 8 12-year-olds in pairs. It is noted that the project was intended to create a rich, multimedia database environment…
Beby, Francis; Des Portes, Vincent; Till, Marianne; Mottolese, Carmine; Denis, Philippe
2012-12-01
The 6p25 deletion syndrome is a rare disorder characterized by Dandy-Walker malformation, congenital heart defects, developmental delay, dysmorphic facial features, and malformations of the anterior segment of the eye with a risk for glaucoma. Here we report a child harboring a cryptic de novo 6p25 deletion, bilateral optic disc coloboma and characteristic anterior segment anomalies. We review reported ophthalmic findings in patients with this syndrome. Retrospective case review of a 4-day-old male with Dandy-Walker malformation and cardiac defects who was referred with a suspected diagnosis of iris coloboma. The ophthalmic examination showed bilateral corectopia associated with posterior embryotoxon. Fundus examination revealed bilateral optic disc excavation, which was diagnosed as colobomatous because of its configuration and stability over time. Because of the association of posterior embryotoxon with Dandy-Walker malformation, a terminal 6p deletion syndrome was clinically suspected. Array comparative genomic hybridization (CGH) and fluorescence in situ hybridization (FISH) studies revealed a 3.2 Mb deletion at 6p25.2p25.3 including the FOXC1 gene. Neither unaffected parent carried this deletion. Optic disc colobomas may be found in patients carrying a 6p25 deletion. This has the potential to confound assessment of affected children for glaucoma and intracranial hypertension.
Kuiper belt analogues in nearby M-type planet-host systems
NASA Astrophysics Data System (ADS)
Kennedy, G. M.; Bryden, G.; Ardila, D.; Eiroa, C.; Lestrade, J.-F.; Marshall, J. P.; Matthews, B. C.; Moro-Martin, A.; Wyatt, M. C.
2018-06-01
We present the results of a Herschel survey of 21 late-type stars that host planets discovered by the radial velocity technique. The aims were to discover new discs in these systems and to search for any correlation between planet presence and disc properties. In addition to the known disc around GJ 581, we report the discovery of two new discs, in the GJ 433 and GJ 649 systems. Our sample therefore yields a disc detection rate of 14 per cent, higher than the detection rate of 1.2 per cent among our control sample of DEBRIS M-type stars with 98 per cent confidence. Further analysis however shows that the disc sensitivity in the control sample is about a factor of two lower in fractional luminosity than for our survey, lowering the significance of any correlation between planet presence and disc brightness below 98 per cent. In terms of their specific architectures, the disc around GJ 433 lies at a radius somewhere between 1 and 30 au. The disc around GJ 649 lies somewhere between 6 and 30 au, but is marginally resolved and appears more consistent with an edge-on inclination. In both cases the discs probably lie well beyond where the known planets reside (0.06-1.1 au), but the lack of radial velocity sensitivity at larger separations allows for unseen Saturn-mass planets to orbit out to ˜5 au, and more massive planets beyond 5 au. The layout of these M-type systems appears similar to Sun-like star + disc systems with low-mass planets.
A biomechanical study of artificial cervical discs using computer simulation.
Ahn, Hyung Soo; DiAngelo, Denis J
2008-04-15
A virtual simulation model of the subaxial cervical spine was used to study the biomechanical effects of various disc prosthesis designs. To study the biomechanics of different design features of cervical disc arthroplasty devices. Disc arthroplasty is an alternative approach to cervical fusion surgery for restoring and maintaining motion at a diseased spinal segment. Different types of cervical disc arthroplasty devices exist and vary based on their placement and degrees of motion offered. A virtual dynamic model of the subaxial cervical spine was used to study 3 different prosthetic disc designs (PDD): (1) PDD-I: The center of rotation of a spherical joint located at the mid C5-C6 disc, (2) PDD-II: The center of rotation of a spherical joint located 6.5 mm below the mid C5-C6 disc, and (3) PDD-III: The center of rotation of a spherical joint in a plane located at the C5-C6 disc level. A constrained spherical joint placed at the disc level (PDD-I) significantly increased facet loads during extension. Lowering the rotational axis of the spherical joint towards the subjacent body (PDD-II) caused a marginal increase in facet loading during flexion, extension, and lateral bending. Lastly, unconstraining the spherical joint to move freely in a plane (PDD-III) minimized facet load build up during all loading modes. The simulation model showed the impact simple design changes may have on cervical disc dynamics. The predicted facet loads calculated from computer model have to be validated in the experimental study.
Schwarzschild black hole encircled by a rotating thin disc: Properties of perturbative solution
NASA Astrophysics Data System (ADS)
Kotlařík, P.; Semerák, O.; Čížek, P.
2018-04-01
Will [Astrophys. J. 191, 521 (1974), 10.1086/152992] solved the perturbation of a Schwarzschild black hole due to a slowly rotating light concentric thin ring, using Green's functions expressed as infinite-sum expansions in multipoles and in the small mass and rotational parameters. In a previous paper [P. Čížek and O. Semerák, Astrophys. J. Suppl. Ser. 232, 14 (2017), 10.3847/1538-4365/aa876b], we expressed the Green functions in closed form containing elliptic integrals, leaving just summation over the mass expansion. Such a form is more practical for numerical evaluation, but mainly for generalizing the problem to extended sources where the Green functions have to be integrated over the source. We exemplified the method by computing explicitly the first-order perturbation due to a slowly rotating thin disc lying between two finite radii. After finding basic parameters of the system—mass and angular momentum of the black hole and of the disc—we now add further properties, namely those which reveal how the disc gravity influences geometry of the black-hole horizon and those of circular equatorial geodesics (specifically, radii of the photon, marginally bound and marginally stable orbits). We also realize that, in the linear order, no ergosphere occurs and the central singularity remains pointlike, and check the implications of natural physical requirements (energy conditions and subluminal restriction on orbital speed) for the single-stream as well as counter-rotating double-stream interpretations of the disc.
Choroidal thickness in Chinese patients with non-arteritic anterior ischemic optic neuropathy.
Jiang, Libin; Chen, Lanlan; Qiu, Xiujuan; Jiang, Ran; Wang, Yaxing; Xu, Liang; Lai, Timothy Y Y
2016-08-31
Non-arteritic anterior ischemic optic neuropathy (NA-AION) is one of the most common types of ischemic optic neuropathy. Several recent studies suggested that abnormalities of choroidal thickness might be associated with NA-AION. The main objective of this case-control study was to evaluate whether choroidal thickness is an ocular risk factor for the development of NA-AION by evaluating the peripapillary and subfoveal choroidal thicknesses in affected Chinese patients. Forty-four Chinese patients with unilateral NA-AION were recruited and compared with 60 eyes of 60 normal age and refractive-error matched control subjects. Peripapillary and subfoveal choroidal thicknesses were measured by enhanced depth imaging optical coherence tomography. Choroidal thicknesses of eyes with NA-AION and unaffected fellow eyes were compared with normal controls. Choroidal thicknesses of NA-AION eyes with or without optic disc edema were also compared. The correlation between choroidal thickness and retinal nerve fiber layer (RNFL) thickness, logMAR best-corrected visual acuity (BCVA), and the mean deviation (MD) of Humphrey static perimetry in NA-AION eyes were analyzed. The peripapillary choroidal thicknesses at the nasal, nasal inferior and temporal inferior segments in NA-AION eyes with optic disc edema were significantly thicker compared with that of normal subjects (P < 0.05). There was no significant difference in the choroidal thicknesses between the unaffected fellow eyes of NA-AION patients and normal eyes of healthy controls; or between the NA-AION eyes with resolved optic disc edema and normal eyes (all P > 0.05). No significant correlation between choroidal thickness and RNFL thickness, logMAR BCVA and perimetry MD was found in eyes affected by NA-AION (all P > 0.05). Increase in peripapillary choroid thickness in some segments was found in NA-ION eyes with optic disc edema. However, our findings do not support the hypothesis that choroidal thickness is abnormal in Chinese patients with NA-AION compared with normal subjects with similar age and refractive error status.
Optic disc segmentation: level set methods and blood vessels inpainting
NASA Astrophysics Data System (ADS)
Almazroa, A.; Sun, Weiwei; Alodhayb, Sami; Raahemifar, Kaamran; Lakshminarayanan, Vasudevan
2017-03-01
Segmenting the optic disc (OD) is an important and essential step in creating a frame of reference for diagnosing optic nerve head (ONH) pathology such as glaucoma. Therefore, a reliable OD segmentation technique is necessary for automatic screening of ONH abnormalities. The main contribution of this paper is in presenting a novel OD segmentation algorithm based on applying a level set method on a localized OD image. To prevent the blood vessels from interfering with the level set process, an inpainting technique is applied. The algorithm is evaluated using a new retinal fundus image dataset called RIGA (Retinal Images for Glaucoma Analysis). In the case of low quality images, a double level set is applied in which the first level set is considered to be a localization for the OD. Five hundred and fifty images are used to test the algorithm accuracy as well as its agreement with manual markings by six ophthalmologists. The accuracy of the algorithm in marking the optic disc area and centroid is 83.9%, and the best agreement is observed between the results of the algorithm and manual markings in 379 images.
Mansouri, Kaweh; Medeiros, Felipe A.; Tatham, Andrew J.; Marchase, Nicholas; Weinreb, Robert N.
2017-01-01
PURPOSE To determine the repeatability of automated retinal and choroidal thickness measurements with swept-source optical coherence tomography (SS OCT) and the frequency and type of scan artifacts. DESIGN Prospective evaluation of new diagnostic technology. METHODS Thirty healthy subjects were recruited prospectively and underwent imaging with a prototype SS OCT instrument. Undilated scans of 54 eyes of 27 subjects (mean age, 35.1 ± 9.3 years) were obtained. Each subject had 4 SS OCT protocols repeated 3 times: 3-dimensional (3D) 6 × 6-mm raster scan of the optic disc and macula, radial, and line scan. Automated measurements were obtained through segmentation software. Interscan repeatability was assessed by intraclass correlation coefficients (ICCs). RESULTS ICCs for choroidal measurements were 0.92, 0.98, 0.80, and 0.91, respectively, for 3D macula, 3D optic disc, radial, and line scans. ICCs for retinal measurements were 0.39, 0.49, 0.71, and 0.69, respectively. Artifacts were present in up to 9% scans. Signal loss because of blinking was the most common artifact on 3D scans (optic disc scan, 7%; macula scan, 9%), whereas segmentation failure occurred in 4% of radial and 3% of line scans. When scans with image artifacts were excluded, ICCs for choroidal thickness increased to 0.95, 0.99, 0.87, and 0.93 for 3D macula, 3D optic disc, radial, and line scans, respectively. ICCs for retinal thickness increased to 0.88, 0.83, 0.89, and 0.76, respectively. CONCLUSIONS Improved repeatability of automated choroidal and retinal thickness measurements was found with the SS OCT after correction of scan artifacts. Recognition of scan artifacts is important for correct interpretation of SS OCT measurements. PMID:24531020
[A case of MEWDS. "The multiple evanescent white-dot syndrome"].
Lefrançois, A; Hamard, H; Corbe, C; Schmitt, A; Badelon, I; Vidal, A
1989-01-01
A young white man developed acute bilateral visual loss with no previous general illness. Ophthalmoscopic examination showed multiple small yellow-white lesions scattered throughout the posterior poles and mild periphery fundus. There was also fine granularity of two foveal areas and one optic disc margin was blurred. Fluorescein angiography showed early hyperfluorescence of the lesions and late staining of the retinal pigment epithelium. Electrophysiologic abnormalities were transient, asymmetric, more marked in photopic than in scotopic. The origin could be in retinal bipolar cells. These lesions regressed, with return of normal visual function within several weeks. These clinical findings are different from others acute inflammatory diseases primarily involving retinal pigment epithelium and photoreceptors. This aspect is usually described as "multiple evanescent white dot syndrome". The etiology of this syndrome remains unknown with no evidence of systemic disease. A history of flulike illness is rare.
Maekubo, Tomoyuki; Chuman, Hideki; Nao-I, Nobuhisa
2013-07-01
The aim of this study was to investigate the usefulness of laser speckle flowgraphy (LSFG) for the differentiation of acute nonarteritic ischemic optic neuropathy (NAION) from anterior optic neuritis (ON). To investigate blood flow in the optic disc under normal conditions, NAION, and anterior ON, we compared the tissue blood flow of the right eye with that of the left eye in the control group, and that of the affected eye with that of the unaffected eye in the NAION and anterior ON groups. In the normal control group, the tissue blood flow did not significantly differ between the right and left eyes. In the NAION group, all 6 patients had decreased optic disc blood flow in the NAION eye when compared with the unaffected eye. By contrast, in the anterior ON group, all 6 patients had increased optic disc blood flow in the anterior ON eye when compared with the unaffected eye. In the NAION group, the mean blur rate (MBR) of the affected eyes was 29.5 % lower than that of the unaffected eyes. In the anterior ON group, the MBR of the affected eyes was 15.9 % higher than that of the unaffected eyes. LSFG could be useful in differentiating between NAION and anterior ON. In addition, this imaging technique saves time and is noninvasive.
Tracking dynamics of photoreceptor disc shedding with adaptive optics-optical coherence tomography
NASA Astrophysics Data System (ADS)
Zhang, Furu; Liu, Zhuolin; Kurokawa, Kazuhiro; Miller, Donald T.
2017-02-01
Absorption of light by photoreceptors initiates vision, but also leads to accumulation of toxic photo-oxidative compounds in the photoreceptor outer segment (OS). To prevent this buildup, small packets of OS discs are periodically pruned from the distal end of the OS, a process called disc shedding. Unfortunately dysfunction in any part of the shedding event can lead to photoreceptor and RPE dystrophy, and has been implicated in numerous retinal diseases, including age related macular degeneration and retinitis pigmentosa. While much is known about the complex molecular and signaling pathways that underpin shedding, all of these advancements have occurred in animal models using postmortem eyes. How these translate to the living retina and to humans remain major obstacles. To that end, we have recently discovered the optical signature of cone OS disc shedding in the living human retina, measured noninvasively using optical coherence tomography equipped with adaptive optics in conjunction with post processing methods to track and monitor individual cones in 4D. In this study, we improve on this method in several key areas: increasing image acquisition up to MHz A-scan rates, improving reliability to detect disc shedding events, establishing system precision, and developing cone tracking for use across the entire awake cycle. Thousands of cones were successfully imaged and tracked over the 17 hour period in two healthy subjects. Shedding events were detected in 79.5% and 77.4% of the tracked cones. Similar to previous animal studies, shedding prevalence exhibited a diurnal rhythm. But we were surprised to find that for these two subjects shedding occurred across the entire day with broad, elevated frequency in the morning and decreasing frequency as the day progressed. Consistent with this, traces of the average cone OS length revealed shedding dominated in the morning and afternoon and renewal in the evening.
Longitudinal analysis of progression in glaucoma using spectral-domain optical coherence tomography.
Wessel, Julia M; Horn, Folkert K; Tornow, Ralf P; Schmid, Matthias; Mardin, Christian Y; Kruse, Friedrich E; Juenemann, Anselm G; Laemmer, Robert
2013-05-01
To compare the longitudinal loss of RNFL thickness measurements by SD-OCT in healthy individuals and glaucoma patients with or without progression concerning optic disc morphology. A total of 62 eyes, comprising 38 glaucomatous eyes with open angle glaucoma and 24 healthy controls, were included in the study (Erlangen Glaucoma Registry, NTC00494923). All patients were investigated annually over a period of 3 years by Spectralis SD-OCT measuring peripapillary RNFL thickness. By masked comparative analysis of photographs, the eyes were classified into nonprogressive and progressive glaucoma cases. Longitudinal loss of RNFL thickness was compared with morphological changes of optic disc morphology. Mixed model analysis of annual OCT scans revealed an estimated annual decrease of the RNFL thickness by 2.12 μm in glaucoma eyes with progression, whereas glaucoma eyes without progression in optic disc morphology lost 1.18 μm per year in RNFL thickness (P = 0.002). The rate of change in healthy eyes was 0.60 μm and thereby also significantly lower than in glaucoma eyes with progression (P < 0.001). The intrasession variability of three successive measurements without head repositioning was 1.5 ± 0.7 μm. The loss of mean RNFL thickness exceeded the intrasession variability in 60% of nonprogressive eyes, and in 85% of progressive eyes after 3 years. LONGITUDINAL MEASUREMENTS OF RNFL THICKNESS USING SD-OCT SHOW A MORE PRONOUNCED REDUCTION OF RNFL THICKNESS IN PATIENTS WITH PROGRESSION COMPARED WITH PATIENTS WITHOUT PROGRESSION IN GLAUCOMATOUS OPTIC DISC CHANGES. (www.clinicaltrials.gov number, NTC00494923.).
NASA Astrophysics Data System (ADS)
Russell, D. M.; Maitra, D.; Dunn, R. J. H.; Fender, R. P.
2011-09-01
It is now established that thermal disc emission and non-thermal jet emission can both play a role at optical/infrared (OIR) wavelengths in X-ray transients. The spectra of the jet and disc components differ, as do their dependence on mass accretion properties. Here we demonstrate that the OIR colour-magnitude diagrams (CMDs) of the evolution of the X-ray transient XTE J1550-564 in outburst can be used to separate the disc from the jet. Monitoring in two wavebands is all that is required. This outburst in 2000 was well studied, and both disc and jet were known to contribute. During the outburst the data follow a well-defined path in the CMD, describing what would be expected from a heated single-temperature blackbody of approximately constant area, except when the data appear redder than this track. This is due to the non-thermal jet component which dominates the OIR moreso during hard X-ray states at high luminosities, and which is quenched in the soft state. The CMD therefore shows state-dependent hysteresis, in analogy with (but not identical to) the well-established X-ray hardness-intensity diagram of black hole transients. The blackbody originates in the X-ray illuminated, likely unwarped, outer accretion disc. We show that the CMD can be approximately reproduced by a model that assumes various correlations between X-ray, OIR disc and OIR jet fluxes. We find evidence for the OIR jet emission to be decoupled from the disc near the peak of the hard state.
Yu, Kai; Shi, Fei; Gao, Enting; Zhu, Weifang; Chen, Haoyu; Chen, Xinjian
2018-01-01
Optic nerve head (ONH) is a crucial region for glaucoma detection and tracking based on spectral domain optical coherence tomography (SD-OCT) images. In this region, the existence of a “hole” structure makes retinal layer segmentation and analysis very challenging. To improve retinal layer segmentation, we propose a 3D method for ONH centered SD-OCT image segmentation, which is based on a modified graph search algorithm with a shared-hole and locally adaptive constraints. With the proposed method, both the optic disc boundary and nine retinal surfaces can be accurately segmented in SD-OCT images. An overall mean unsigned border positioning error of 7.27 ± 5.40 µm was achieved for layer segmentation, and a mean Dice coefficient of 0.925 ± 0.03 was achieved for optic disc region detection. PMID:29541497
Miyata, Manabu; Yoshikawa, Munemitsu; Ohtsuki, Hiroshi; Muraoka, Yuki; Hata, Masayuki; Yokota, Satoshi; Fujimoto, Masahiro; Miyake, Masahiro; Tabara, Yasuharu; Matsuda, Fumihiko; Yoshimura, Nagahisa
2018-01-25
To analyse the disc-fovea angle (DFA) by age group and to compare sex differences in each age group in a large cohort population. This community-based cross-sectional cohort study included 9682 eyes of 9682 volunteers (aged 30-75 years). We measured the DFA, which is the angle between a horizontal line and a line connecting the fovea with the centroid of an optic disc on fundus photographs of the right eye. We manually marked the fovea and surrounded the optic disc. The centroid of an optic disc and the DFA was automatically calculated using originally developed software. We compared the DFA between age groups in 10-year increments and investigated sex differences of DFA in each age group. Overall mean DFA was 6.32 ± 3.53°. The DFA of older subjects was significantly larger than that of younger subjects (p < 0.001). The DFA of women was larger than that of men in their 60s and 70s (p < 0.001 for both), but not in subjects in their 30s, 40s and 50s. Larger DFA in women than in men in their 60s and 70s suggests the possibility that age-related excyclo-shift occurs more easily in postmenopausal women compared to men of the same age. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Disc resonator gyroscope fabrication process requiring no bonding alignment
NASA Technical Reports Server (NTRS)
Shcheglov, Kirill V. (Inventor)
2010-01-01
A method of fabricating a resonant vibratory sensor, such as a disc resonator gyro. A silicon baseplate wafer for a disc resonator gyro is provided with one or more locating marks. The disc resonator gyro is fabricated by bonding a blank resonator wafer, such as an SOI wafer, to the fabricated baseplate, and fabricating the resonator structure according to a pattern based at least in part upon the location of the at least one locating mark of the fabricated baseplate. MEMS-based processing is used for the fabrication processing. In some embodiments, the locating mark is visualized using optical and/or infrared viewing methods. A disc resonator gyroscope manufactured according to these methods is described.
Army Medical Imaging System - ARMIS
1992-08-08
modems , scanners, hard disk drives, dot matrix printers, erasable-optical disc drives, CD-ROM drives, WORM disc drives and tape drives are fully...can use 56K leased lines, TI links, digital data circuits, or public telephone lines. 3. ISDN The Integrated Services Digital Network, ISDN, is a
Neuro-Ophthalmology at a Tertiary Eye Care Centre in India.
Dhiman, Rebika; Singh, Digvijay; Gantayala, Shiva P; Ganesan, Vaitheeswaran L; Sharma, Pradeep; Saxena, Rohit
2017-11-09
Neuro-ophthalmology as a specialty is underdeveloped in India. The aim of our study was to determine the spectrum and profile of patients presenting to a tertiary eye care center with neuro-ophthalmic disorders. A retrospective hospital-based study was conducted, and records of all patients seen at the neuro-ophthalmology clinic of Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India, over a 1-year period were retrieved and evaluated. Of a total of 30,111 patients referred to various specialty clinics in a span of 1 year, 1597 (5%) were referred for neuro-ophthalmology evaluation. The mean patient age was 30.8 ± 19.5 years, with a male dominance (M:F = 2.02:1). Among these patients, optic nerve disorders were noted in 63.8% (n = 1,020), cranial nerve palsy in 7% (n = 114), cortical visual impairment in 6.5% (n = 105), and others (eye/optic nerve hypophasia, blepharospasm, and optic disc drusen) in 6% (n = 95). Among the patients with optic nerve disorders, optic neuropathy without disc edema/(traumatic optic neuropathy, hereditary, tumor-related, retrobulbar neuritis, toxic, and idiopathic) was noted in 42.8% (n = 685) and optic neuropathy with disc edema (ischemic optic neuropathy, papilledema, post-papilledema optic atrophy, papillitis, neuroretinitis, and inflammatory optic neuropathy) in 20.9% (n = 335). Sixteen percent of patients (n = 263) were incorrect referrals. The neuro-ophthalmic clinic constitutes a significant referral unit in a tertiary eye care center in India. Traumatic and ischemic optic neuropathies are the most common diagnoses. Neuro-ophthalmology requires further development as a subspecialty in India to better serve the nation's population.
Optical Coherence Tomography Angiography in Optic Disc Swelling.
Fard, Masoud Aghsaei; Jalili, Jalil; Sahraiyan, Alireza; Khojasteh, Hassan; Hejazi, Marjane; Ritch, Robert; Subramanian, Prem S
2018-05-04
To compare optical coherence tomography angiography (OCT-A) of peripapillary total vasculature and capillaries in patients with optic disc swelling. Cross-sectional study. Twenty nine eyes with acute nonarteritic anterior ischemic optic neuropathy (NAION), 44 eyes with papilledema, 8 eyes with acute optic neuritis, and 48 eyes of normal subjects were imaged using OCT-A. Peripapillary total vasculature information was recorded using a commercial vessel density map. Customized image analysis with major vessel removal was also used to measure whole-image capillary density and peripapillary capillary density (PCD). Mixed models showed that the peripapillary total vasculature density values were significantly lower in NAION eyes, followed by papilledema eyes and control eyes, using commercial software (P < .0001 for all comparisons). The customized software also showed significantly lower PCD of NAION eyes compared with papilledema eyes (all P < .001), but did not show significant differences between papilledema and control subjects. Our software showed significantly lower whole image and PCD in eyes with optic neuritis than papilledema. There was no significant difference between NAION and optic neuritis using our software. The area under the receiver operating curves for discriminating NAION from papilledema eyes and optic neuritis from papilledema eyes was highest for whole-image capillary density (0.94 and 0.80, respectively) with our software, followed by peripapillary total vasculature (0.9 and 0.74, respectively ) with commercial software. OCT-A is helpful to distinguish NAION and papillitis from papilledema. Whole-image capillary density had the greatest diagnostic accuracy for differentiating disc swelling. Copyright © 2018 Elsevier Inc. All rights reserved.
Cordeiro, Daniela Valença; Lima, Verônica Castro; Castro, Dinorah P; Castro, Leonardo C; Pacheco, Maria Angélica; Lee, Jae Min; Dimantas, Marcelo I; Prata, Tiago Santos
2011-01-01
To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma. Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 × 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm(2) disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each. Average mean deviation index for glaucomatous eyes was -5.3 ± 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19). The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P ≥ 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm(2)) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities - at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) - were found with disc sizes fixed at 1.5 mm(2) and 2.5 mm(2). Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect was observed.
The transiting dust clumps in the evolved disc of the Sun-like UXor RZ Psc.
Kennedy, Grant M; Kenworthy, Matthew A; Pepper, Joshua; Rodriguez, Joseph E; Siverd, Robert J; Stassun, Keivan G; Wyatt, Mark C
2017-01-01
RZ Psc is a young Sun-like star, long associated with the UXor class of variable stars, which is partially or wholly dimmed by dust clumps several times each year. The system has a bright and variable infrared excess, which has been interpreted as evidence that the dimming events are the passage of asteroidal fragments in front of the host star. Here, we present a decade of optical photometry of RZ Psc and take a critical look at the asteroid belt interpretation. We show that the distribution of light curve gradients is non-uniform for deep events, which we interpret as possible evidence for an asteroidal fragment-like clump structure. However, the clumps are very likely seen above a high optical depth midplane, so the disc's bulk clumpiness is not revealed. While circumstantial evidence suggests an asteroid belt is more plausible than a gas-rich transition disc, the evolutionary status remains uncertain. We suggest that the rarity of Sun-like stars showing disc-related variability may arise because (i) any accretion streams are transparent and/or (ii) turbulence above the inner rim is normally shadowed by a flared outer disc.
The transiting dust clumps in the evolved disc of the Sun-like UXor RZ Psc
NASA Astrophysics Data System (ADS)
Kennedy, Grant M.; Kenworthy, Matthew A.; Pepper, Joshua; Rodriguez, Joseph E.; Siverd, Robert J.; Stassun, Keivan G.; Wyatt, Mark C.
2017-01-01
RZ Psc is a young Sun-like star, long associated with the UXor class of variable stars, which is partially or wholly dimmed by dust clumps several times each year. The system has a bright and variable infrared excess, which has been interpreted as evidence that the dimming events are the passage of asteroidal fragments in front of the host star. Here, we present a decade of optical photometry of RZ Psc and take a critical look at the asteroid belt interpretation. We show that the distribution of light curve gradients is non-uniform for deep events, which we interpret as possible evidence for an asteroidal fragment-like clump structure. However, the clumps are very likely seen above a high optical depth midplane, so the disc's bulk clumpiness is not revealed. While circumstantial evidence suggests an asteroid belt is more plausible than a gas-rich transition disc, the evolutionary status remains uncertain. We suggest that the rarity of Sun-like stars showing disc-related variability may arise because (i) any accretion streams are transparent and/or (ii) turbulence above the inner rim is normally shadowed by a flared outer disc.
ERIC Educational Resources Information Center
Gale, John C.; And Others
1985-01-01
This four-article section focuses on information storage capacity of the optical disk covering the information workstation (uses microcomputer, optical disk, compact disc to provide reference information, information content, work product support); use of laser videodisc technology for dissemination of agricultural information; encoding databases…
M, Soorya; Issac, Ashish; Dutta, Malay Kishore
2018-02-01
Glaucoma is an ocular disease which can cause irreversible blindness. The disease is currently identified using specialized equipment operated by optometrists manually. The proposed work aims to provide an efficient imaging solution which can help in automating the process of Glaucoma diagnosis using computer vision techniques from digital fundus images. The proposed method segments the optic disc using a geometrical feature based strategic framework which improves the detection accuracy and makes the algorithm invariant to illumination and noise. Corner thresholding and point contour joining based novel methods are proposed to construct smooth contours of Optic Disc. Based on a clinical approach as used by ophthalmologist, the proposed algorithm tracks blood vessels inside the disc region and identifies the points at which first vessel bend from the optic disc boundary and connects them to obtain the contours of Optic Cup. The proposed method has been compared with the ground truth marked by the medical experts and the similarity parameters, used to determine the performance of the proposed method, have yield a high similarity of segmentation. The proposed method has achieved a macro-averaged f-score of 0.9485 and accuracy of 97.01% in correctly classifying fundus images. The proposed method is clinically significant and can be used for Glaucoma screening over a large population which will work in a real time. Copyright © 2017 Elsevier B.V. All rights reserved.
Normal versus High Tension Glaucoma: A Comparison of Functional and Structural Defects
Thonginnetra, Oraorn; Greenstein, Vivienne C.; Chu, David; Liebmann, Jeffrey M.; Ritch, Robert; Hood, Donald C.
2009-01-01
Purpose To compare visual field defects obtained with both multifocal visual evoked potential (mfVEP) and Humphrey visual field (HVF) techniques to topographic optic disc measurements in patients with normal tension glaucoma (NTG) and high tension glaucoma (HTG). Methods We studied 32 patients with NTG and 32 with HTG. All patients had reliable 24-2 HVFs with a mean deviation (MD) of −10 dB or better, a glaucomatous optic disc and an abnormal HVF in at least one eye. Multifocal VEPs were obtained from each eye and probability plots created. The mfVEP and HVF probability plots were divided into a central 10-degree (radius) and an outer arcuate subfield in both superior and inferior hemifields. Cluster analyses and counts of abnormal points were performed in each subfield. Optic disc images were obtained with the Heidelberg Retina Tomograph III (HRT III). Eleven stereometric parameters were calculated. Moorfields regression analysis (MRA) and the glaucoma probability score (GPS) were performed. Results There were no significant differences in MD and PSD values between NTG and HTG eyes. However, NTG eyes had a higher percentage of abnormal test points and clusters of abnormal points in the central subfields on both mfVEP and HVF than HTG eyes. For HRT III, there were no significant differences in the 11 stereometric parameters or in the MRA and GPS analyses of the optic disc images. Conclusions The visual field data suggest more localized and central defects for NTG than HTG. PMID:19223786
NASA Astrophysics Data System (ADS)
Zhou, Gan; An, Xin; Pu, Allen; Psaltis, Demetri; Mok, Fai H.
1999-11-01
The holographic disc is a high capacity, disk-based data storage device that can provide the performance for next generation mass data storage needs. With a projected capacity approaching 1 terabit on a single 12 cm platter, the holographic disc has the potential to become a highly efficient storage hardware for data warehousing applications. The high readout rate of holographic disc makes it especially suitable for generating multiple, high bandwidth data streams such as required for network server computers. Multimedia applications such as interactive video and HDTV can also potentially benefit from the high capacity and fast data access of holographic memory.
Glaucoma management in patients with osteo-odonto-keratoprosthesis (OOKP): the Singapore OOKP Study.
Kumar, Rajesh S; Tan, Donald T H; Por, Yong-Ming; Oen, Francis T; Hoh, Sek-Tien; Parthasarathy, Anand; Aung, Tin
2009-01-01
To report diagnostic modalities and treatment options for glaucoma in eyes with osteo-odonto keratoprosthesis (OOKP). Eyes that underwent OOKP were evaluated for glaucoma at the time of the first postoperative visit, then at 1 and 3 months after the procedure, and thereafter every 6 months. All eyes underwent stereo-biomicroscopic optic nerve head (ONH) assessment, kinetic (Goldmann perimetry) and automated static visual field testing, ONH photography, Heidelberg retina tomograph, scanning laser polarimetery (GDx), and optical coherence tomography. Treatment of glaucoma was also reviewed. Average follow-up period was 19.1 (range: 5 to 31) months. Of the 15 eyes that underwent OOKP, 5 eyes had preexisting glaucoma. None of the other 10 eyes developed glaucoma after OOKP. ONH photography and visual field testing were the most reliable methods to assess status of the disease, whereas Heidelberg retina tomograph and optical coherence tomography could be performed with reasonable reproducibility and quality; GDx imaging was poor. All patients with glaucoma were treated with oral acetazolamide 500 mg twice a day. Transscleral cyclophotocoagulation was performed in 3 eyes at stage 2 of OOKP surgery. Progression of glaucoma was noted in 2 eyes on the basis of optic disc photographs and automated perimetry. Visual field testing and optic disc assessment with optic disc photographs seem to be effective methods to monitor eyes with OOKP for glaucoma. Treatment strategies include oral medications to lower intraocular pressure and cyclophotocoagulation.
Güven, Dilek; Balcıoğlu, Nihal; Türker, Cağrı; Baydar, Yasemin; Sendül, Yekta
2013-12-01
Serous macular detachment (SMD) may accompany optic disc pit (ODP) and cause visual loss if untreated. We want to present different therapeutic approaches and interesting optical coherence tomography (OCT) findings in three consecutive cases. In this case series, two patients with SMD and one patient with partial macular detachment and inferior retinal detachment accompanying ODP were evaluated before and after surgical intervention clinically and by spectral-domain OCT. The patients were 44 (case 1), 22 (case 2) and 24 (case 3) years old. Pars plana vitrectomy (PPV) + silicone oil + laser, PPV + sulfur hexafluoride gas (SF6) + laser and pneumatic retinopexy were applied, respectively. The patients were followed for 18, 15 and 14 months. Preoperative best-corrected visual acuities (BCVAs) were 5/100, 7/10 and counting fingers at 1 m. Vision improved in all cases with resolution of subretinal fluid. Final BCVAs were 3/10, 10/10 and 1/10, respectively. OCT images revealed optic disc anomaly details and changes after surgical intervention, photoreceptor outer segment alterations at the detached area and macular surface changes. Surgical intervention should be tailored individually in cases with SMD. OCT is efficient for in vivo evaluation of this pathological condition and anatomical outcomes of surgery.
Combining morphometric features and convolutional networks fusion for glaucoma diagnosis
NASA Astrophysics Data System (ADS)
Perdomo, Oscar; Arevalo, John; González, Fabio A.
2017-11-01
Glaucoma is an eye condition that leads to loss of vision and blindness. Ophthalmoscopy exam evaluates the shape, color and proportion between the optic disc and physiologic cup, but the lack of agreement among experts is still the main diagnosis problem. The application of deep convolutional neural networks combined with automatic extraction of features such as: the cup-to-disc distance in the four quadrants, the perimeter, area, eccentricity, the major radio, the minor radio in optic disc and cup, in addition to all the ratios among the previous parameters may help with a better automatic grading of glaucoma. This paper presents a strategy to merge morphological features and deep convolutional neural networks as a novel methodology to support the glaucoma diagnosis in eye fundus images.
Optic Disc Melanocytoma Report of 5 Patients From Singapore With a Review of the Literature.
Lee, Elin; Sanjay, Srinivasan
2015-01-01
The aim of this study was to report the clinical features of optic disc melanocytoma (ODMC). This study was a retrospective case series. Five patients (6 eyes) with ODMC followed up over a mean duration of 3 years (range, 4-61 months) were included in this series. The mean age of diagnosis was 55.2 years with Chinese female predominance. Four of 6 ODMCs were unilateral with predominance to the left side. Four patients had visual acuity of 6/9 or better at presentation, and all ODMCs were discovered incidentally. All ODMCs were black, with an average size of 0.8 disc diameter and partially covering the optic disc. Five of 6 ODMCs were inferiorly located and involved adjacent choroid and retina. Three of 6 ODMCs had ill-defined borders. Fundus fluorescein angiogram findings in 1 patient showed blocked fluorescence due to pigments. No loss of visual acuity of 2 or more Snellen lines, ODMC enlargement, or malignant transformation were noted in any patients during follow-up. There were no local complications. Ocular and systemic associations were not seen. Our case series did not show any features of progression during our follow-up. Annual fundoscopic examinations are still important to detect enlargement and malignant transformation.
Microstructure of the optic disc pit in open-angle glaucoma.
Choi, Yun Jeong; Lee, Eun Ji; Kim, Bo Hyuk; Kim, Tae-Woo
2014-11-01
To investigate the structural and clinical characteristics of the optic disc pit (ODP) in primary open-angle glaucoma (POAG) via enhanced depth imaging (EDI) spectral-domain optical coherence tomography (SD-OCT). Prospective, observational case series. Seventy POAG eyes clinically diagnosed with an ODP via stereo disc photography. Optic discs were scanned using EDI SD-OCT. Serial horizontal and vertical B-scan images covering the optic discs were obtained from each eye. The structural characteristics of the ODP were investigated via 3-dimensional images constructed from the serial B-scans, focusing on the presence of alterations in the contour of the lamina cribrosa (LC) or prelaminar tissue (PLT), in conjunction with associated clinical characteristics. The structural characteristics of the ODP and associated clinical characteristics. In the EDI SD-OCT images, the ODP was viewed as an isolated alteration of the LC (n = 14, 20.0%) or PLT (n = 16, 22.9%) or an alteration of both the LC and PLT (n = 40, 57.1%). Alterations of the LC were located at the mid-periphery near the LC insertion (n = 17) or far periphery adjacent to the LC insertion (n = 37), and the depth of alteration was deep (n = 23), involving nearly full-thickness LC, or shallow (n = 31), with partially visible LC at the base. Fifty-four eyes (77.1%) exhibited parafoveal visual field (VF) defect within 10 degrees of fixation, and in 98.1% of these eyes (53/54) it was spatially associated with the location of ODP. The parafoveal VF defect was more prevalent in eyes with LC alteration than those without (83.3% vs. 56.2%, P = 0.023) and in eyes with deep LC defect than those with shallow defect (95.7% vs. 74.2%, P = 0.036). Disc hemorrhage (32.4% vs. 0.0%, P = 0.008) and peripapillary retinoschisis (18.9 vs. 0.0%, P = 0.055) were more strongly associated with LC alterations located at the far periphery than at the mid-periphery. Enhanced depth imaging SD-OCT facilitated visualization of the varied structure of the ODP, which presented as alteration of the LC or PLT or both. The clinical significance of differing characteristics of ODP microstructure remains to be determined. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Morphometric analysis of the working zone for endoscopic lumbar discectomy.
Min, Jun-Hong; Kang, Shin-Hyuk; Lee, Jang-Bo; Cho, Tai-Hyoung; Suh, Jung-Keun; Rhyu, Im-Joo
2005-04-01
Our study's purpose was to analyze the working zone for the current practice of endoscopic discectomy at the lateral exit zone of the intervertebral foramen (IVF) and to define a safe point for clinical practice. One hundred eighty-six nerve roots of the lumbar IVFs of cadaveric spines were studied. Upon lateral inspection, we measured the distance from the nerve root to the most dorsolateral margin of the disc and to the lateral edge of the superior articular process of the vertebra below at the plane of the superior endplate of the vertebra below. The angle between the root and the plane of the disc was also measured. The results showed that the mean distance from the nerve root to the most dorsolateral margin of the disc was 3.4 +/- 2.7 mm (range 0.0-10.8 mm), the mean distance from the nerve root to the lateral edge of the superior articular process of the vertebra below was 11.6 +/- 4.6 mm (range 4.1-24.3 mm), and the mean angle between the nerve root and the plane of the disc was 79.1 degrees +/- 7.6 degrees (range 56.0-90.0 degrees ). The values of the base of the working zone have a wide distribution. Blind puncture of annulus by the working cannula or obturator may be dangerous. The safer procedure would be the direct viewing of the annulus by endoscopy before annulotomy; the working cannula should be inserted into the foramen as close as possible to the facet joint.
Dhafiri, Yousef; Al Rubaie, Khalid; Kirat, Omar; May, William N; Nguyen, Quan D; Kozak, Igor
2017-01-01
The purpose of this study is to describe an association of unilateral multifocal choroiditis (MFC), retinal vasculitis, optic neuropathy, and bilateral keratoconus in a young Saudi male. A 27-year-old male patient with stable bilateral keratoconus presented with a painless vision loss in his left eye. Ophthalmic examinations revealed multiple foci of idiopathic chorioretinitis, retinal vasculitis, and mild optic disc leakage on fluorescein angiography, all of which resolved on systemic therapy with mycophenolate mofetil and prednisone after 3 months. Systemic medication was stopped after 8 months. One year after presentation, patient's visual acuity has improved and remained stable. Systemic immunomodulatory therapy can be effective in managing and leading to resolution of MFC, retinal vasculitis, and optic disc leak in young patients.
Larrosa, José Manuel; Moreno-Montañés, Javier; Martinez-de-la-Casa, José María; Polo, Vicente; Velázquez-Villoria, Álvaro; Berrozpe, Clara; García-Granero, Marta
2015-10-01
The purpose of this study was to develop and validate a multivariate predictive model to detect glaucoma by using a combination of retinal nerve fiber layer (RNFL), retinal ganglion cell-inner plexiform (GCIPL), and optic disc parameters measured using spectral-domain optical coherence tomography (OCT). Five hundred eyes from 500 participants and 187 eyes of another 187 participants were included in the study and validation groups, respectively. Patients with glaucoma were classified in five groups based on visual field damage. Sensitivity and specificity of all glaucoma OCT parameters were analyzed. Receiver operating characteristic curves (ROC) and areas under the ROC (AUC) were compared. Three predictive multivariate models (quantitative, qualitative, and combined) that used a combination of the best OCT parameters were constructed. A diagnostic calculator was created using the combined multivariate model. The best AUC parameters were: inferior RNFL, average RNFL, vertical cup/disc ratio, minimal GCIPL, and inferior-temporal GCIPL. Comparisons among the parameters did not show that the GCIPL parameters were better than those of the RNFL in early and advanced glaucoma. The highest AUC was in the combined predictive model (0.937; 95% confidence interval, 0.911-0.957) and was significantly (P = 0.0001) higher than the other isolated parameters considered in early and advanced glaucoma. The validation group displayed similar results to those of the study group. Best GCIPL, RNFL, and optic disc parameters showed a similar ability to detect glaucoma. The combined predictive formula improved the glaucoma detection compared to the best isolated parameters evaluated. The diagnostic calculator obtained good classification from participants in both the study and validation groups.
The binary millisecond pulsar PSR J1023+0038 during its accretion state - I. Optical variability
NASA Astrophysics Data System (ADS)
Shahbaz, T.; Linares, M.; Nevado, S. P.; Rodríguez-Gil, P.; Casares, J.; Dhillon, V. S.; Marsh, T. R.; Littlefair, S.; Leckngam, A.; Poshyachinda, S.
2015-11-01
We present time-resolved optical photometry of the binary millisecond `redback' pulsar PSR J1023+0038 (=AY Sex) during its low-mass X-ray binary phase. The light curves taken between 2014 January and April show an underlying sinusoidal modulation due to the irradiated secondary star and accretion disc. We also observe superimposed rapid flaring on time-scales as short as ˜20 s with amplitudes of ˜0.1-0.5 mag and additional large flare events on time-scales of ˜5-60 min with amplitudes of ˜0.5-1.0 mag. The power density spectrum of the optical flare light curves is dominated by a red-noise component, typical of aperiodic activity in X-ray binaries. Simultaneous X-ray and UV observations by the Swift satellite reveal strong correlations that are consistent with X-ray reprocessing of the UV light, most likely in the outer regions of the accretion disc. On some nights we also observe sharp-edged, rectangular, flat-bottomed dips randomly distributed in orbital phase, with a median duration of ˜250 s and a median ingress/egress time of ˜20 s. These rectangular dips are similar to the mode-switching behaviour between disc `active' and `passive' luminosity states, observed in the X-ray light curves of other redback millisecond pulsars. This is the first time that the optical analogue of the X-ray mode-switching has been observed. The properties of the passive- and active-state light curves can be explained in terms of clumpy accretion from a trapped inner accretion disc near the corotation radius, resulting in rectangular, flat-bottomed optical and X-ray light curves.
Bruder, Friedrich-Karl; Hagen, Rainer; Rölle, Thomas; Weiser, Marc-Stephan; Fäcke, Thomas
2011-05-09
Optical data storage has had a major impact on daily life since its introduction to the market in 1982. Compact discs (CDs), digital versatile discs (DVDs), and Blu-ray discs (BDs) are universal data-storage formats with the advantage that the reading and writing of the digital data does not require contact and is therefore wear-free. These formats allow convenient and fast data access, high transfer rates, and electricity-free data storage with low overall archiving costs. The driving force for development in this area is the constant need for increased data-storage capacity and transfer rate. The use of holographic principles for optical data storage is an elegant way to increase the storage capacity and the transfer rate, because by this technique the data can be stored in the volume of the storage material and, moreover, it can be optically processed in parallel. This Review describes the fundamental requirements for holographic data-storage materials and compares the general concepts for the materials used. An overview of the performance of current read-write devices shows how far holographic data storage has already been developed. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hannibal, Matthew; Thomas, Derek J; Low, Jeffrey; Hsu, Ken Y; Zucherman, James
2007-10-01
This is a retrospective analysis of data that was collected prospectively from 2 concurrent FDA IDE lumbar arthroplasty clinical trials performed at a single center. To determine if there is a clinical difference between the 1-level ProDisc patients versus the 2-level ProDisc patients at a minimum of 2 years of follow-up. Marnay's work with ProDisc I prompted the U.S. Clinical Trials of the ProDisc II under the direction of the FDA. Disc replacement surgery in the United States has shown promising results for all types of prostheses up to 6 months. Marnay and colleagues showed that their results at 10 years were still promising, and they saw no significant difference between 1-level and multilevel disc replacements. The findings of Ipsen and colleagues suggest that multilevel arthroplasty cases may be less successful than disc replacement at a single level. Patients were part of the FDA clinical trial for the Prodisc II versus circumferential fusion study at a single institution. We identified 27 patients who received ProDisc at 1 level and 32 who received it at 2 levels with at least a 2-year follow-up, for a total of 59 patients. Unpaired t tests were performed on the mean results of Visual Analog Scale, Oswestry Disability Index, SF-36 Healthy Survey Physical Component Summary, and satisfaction using 10-cm line visual scale scores to determine a clinical difference if any between the 2 populations. While patients receiving ProDisc at 2 levels scored marginally lower in all evaluation indexes, score differences in each category were also found to hold no statistical significance. This study was unable to identify a statistically significant difference in outcome between 1- and 2-level ProDisc arthroplasty patients in a cohort from a single center. The equality of clinical effectiveness between 1- and 2-level ProDisc has yet to be determined.
DeLucca, John F.; Peloquin, John M.; Smith, Lachlan J.; Wright, Alexander C.; Vresilovic, Edward J.; Elliott, Dawn M.
2017-01-01
Geometry is an important indicator of disc mechanical function and degeneration. While the geometry and associated degenerative changes in the nucleus pulposus and the annulus fibrosus are well-defined, the geometry of the cartilage endplate (CEP) and its relationship to disc degeneration are unknown. The objectives of this study were to quantify CEP geometry in three dimensions using an MRI FLASH imaging sequence and evaluate relationships between CEP geometry and age, degeneration, spinal level, and overall disc geometry. To do so, we assessed the MRI-based measurements for accuracy and repeatability. Next, we measured CEP geometry across a larger sample set and correlated CEP geometric parameters to age, disc degeneration, level, and disc geometry. The MRI-based measures resulted in thicknesses (0.3–1 mm) that are comparable to prior measurements of CEP thickness. CEP thickness was greatest at the anterior/posterior (A/P) margins and smallest in the center. The CEP A/P thickness, axial area, and lateral width decreased with age but were not related to disc degeneration. Age-related, but not degeneration-related, changes in geometry suggest that the CEP may not follow the progression of disc degeneration. Ultimately, if the CEP undergoes significant geometric changes with aging and if these can be related to low back pain, a clinically feasible translation of the FLASH MRI-based measurement of CEP geometry presented in this study may prove a useful diagnostic tool. PMID:27232974
Kuiper belt structure around nearby super-Earth host stars
NASA Astrophysics Data System (ADS)
Kennedy, Grant M.; Matrà, Luca; Marmier, Maxime; Greaves, Jane S.; Wyatt, Mark C.; Bryden, Geoffrey; Holland, Wayne; Lovis, Christophe; Matthews, Brenda C.; Pepe, Francesco; Sibthorpe, Bruce; Udry, Stéphane
2015-05-01
We present new observations of the Kuiper belt analogues around HD 38858 and HD 20794, hosts of super-Earth mass planets within 1 au. As two of the four nearby G-type stars (with HD 69830 and 61 Vir) that form the basis of a possible correlation between low-mass planets and debris disc brightness, these systems are of particular interest. The disc around HD 38858 is well resolved with Herschel and we constrain the disc geometry and radial structure. We also present a probable James Clerk Maxwell Telescope sub-mm continuum detection of the disc and a CO J = 2-1 upper limit. The disc around HD 20794 is much fainter and appears marginally resolved with Herschel, and is constrained to be less extended than the discs around 61 Vir and HD 38858. We also set limits on the radial location of hot dust recently detected around HD 20794 with near-IR interferometry. We present High Accuracy Radial velocity Planet Searcher upper limits on unseen planets in these four systems, ruling out additional super-Earths within a few au, and Saturn-mass planets within 10 au. We consider the disc structure in the three systems with Kuiper belt analogues (HD 69830 has only a warm dust detection), concluding that 61 Vir and HD 38858 have greater radial disc extent than HD 20794. We speculate that the greater width is related to the greater minimum planet masses (10-20 M⊕ versus 3-5 M⊕), arising from an eccentric planetesimal population analogous to the Solar system's scattered disc. We discuss alternative scenarios and possible means to distinguish among them.
NASA Astrophysics Data System (ADS)
Motta, Danilo A.; Serillo, André; de Matos, Luciana; Yasuoka, Fatima M. M.; Bagnato, Vanderlei S.; Carvalho, Luis A. V.
2014-03-01
Glaucoma is the second main cause of the blindness in the world and there is a tendency to increase this number due to the lifetime expectation raise of the population. Glaucoma is related to the eye conditions, which leads the damage to the optic nerve. This nerve carries visual information from eye to brain, then, if it has damage, it compromises the visual quality of the patient. In the majority cases the damage of the optic nerve is irreversible and it happens due to increase of intraocular pressure. One of main challenge for the diagnosis is to find out this disease, because any symptoms are not present in the initial stage. When is detected, it is already in the advanced stage. Currently the evaluation of the optic disc is made by sophisticated fundus camera, which is inaccessible for the majority of Brazilian population. The purpose of this project is to develop a specific fundus camera without fluorescein angiography and red-free system to accomplish 3D image of optic disc region. The innovation is the new simplified design of a stereo-optical system, in order to make capable the 3D image capture and in the same time quantitative measurements of excavation and topography of optic nerve; something the traditional fundus cameras do not do. The dedicated hardware and software is developed for this ophthalmic instrument, in order to permit quick capture and print of high resolution 3D image and videos of optic disc region (20° field-of-view) in the mydriatic and nonmydriatic mode.
NASA Astrophysics Data System (ADS)
Shinoda, Masataka; Saito, Kimihiro; Kondo, Takao; Ishimoto, Tsutomu; Nakaoki, Ariyoshi
2003-02-01
We have investigated high-density near-field readout using a solid immersion lens with a high refractive index. By using a glass material with a high refractive index of 2.08, we developed an optical pick-up with the effective numerical aperture of 1.8. We could observe a clear eye pattern for a 50 GB capacity disc in 120 mm diameter. We confirmed that the near-field readout system is promising method of realizing a high-density optical disc system.
Evolution of optic nerve photography for glaucoma screening: a review.
Myers, Jonathan S; Fudemberg, Scott J; Lee, Daniel
2018-03-01
Visual evaluation of the optic nerve has been one of the earliest and most widely used methods to evaluate patients for glaucoma. Photography has proven very useful for documentation of the nerve's appearance at a given time, allowing more detailed scrutiny then, and later comparison for change. Photography serves as the basis for real-time or non-simultaneous review in telemedicine and screening events allowing fundus and optic nerve evaluation by experts elsewhere. Expert evaluation of disc photographs has shown diagnostic performance similar to other methods of optic nerve evaluation for glaucoma. Newer technology has made optic nerve photography simpler, cheaper and more portable creating opportunities for broader utilization in screening in underserved populations by non-physicians. Recent investigations suggest that non-physicians or software algorithms for disc photograph evaluation have promise to allow more screening to be done with fewer experts. © 2017 Royal Australian and New Zealand College of Ophthalmologists.
Two-dimensional adiabatic flows on to a black hole - I. Fluid accretion
NASA Astrophysics Data System (ADS)
Blandford, Roger D.; Begelman, Mitchell C.
2004-03-01
When gas accretes on to a black hole, at a rate either much less than or much greater than the Eddington rate, it is likely to do so in an `adiabatic' or radiatively inefficient manner. Under fluid (as opposed to magnetohydrodynamic) conditions, the disc should become convective and evolve toward a state of marginal instability. We model the resulting disc structure as `gyrentropic', with convection proceeding along common surfaces of constant angular momentum, Bernouilli function and entropy, called `gyrentropes'. We present a family of two-dimensional, self-similar models that describes the time-averaged disc structure. We then suppose that there is a self-similar, Newtonian torque, which dominates the angular momentum transport and that the Prandtl number is large so that convection dominates the heat transport. The torque drives inflow and meridional circulation and the resulting flow is computed. Convective transport will become ineffectual near the disc surface. It is conjectured that this will lead to a large increase of entropy across a `thermal front', which we identify as the effective disc surface and the base of an outflow. The conservation of mass, momentum and energy across this thermal front permits a matching of the disc models to self-similar outflow solutions. We then demonstrate that self-similar disc solutions can be matched smoothly on to relativistic flows at small radius and thin discs at large radius. This model of adiabatic accretion is contrasted with some alternative models that have been discussed recently. The disc models developed in this paper should be useful for interpreting numerical, fluid dynamical simulations. Related principles to those described here may govern the behaviour of astrophysically relevant, magnetohydrodynamic disc models.
NASA Astrophysics Data System (ADS)
Szulágyi, J.; Mayer, L.; Quinn, T.
2017-01-01
Circumplanetary discs can be found around forming giant planets, regardless of whether core accretion or gravitational instability built the planet. We carried out state-of-the-art hydrodynamical simulations of the circumplanetary discs for both formation scenarios, using as similar initial conditions as possible to unveil possible intrinsic differences in the circumplanetary disc mass and temperature between the two formation mechanisms. We found that the circumplanetary discs' mass linearly scales with the circumstellar disc mass. Therefore, in an equally massive protoplanetary disc, the circumplanetary discs formed in the disc instability model can be only a factor of 8 more massive than their core-accretion counterparts. On the other hand, the bulk circumplanetary disc temperature differs by more than an order of magnitude between the two cases. The subdiscs around planets formed by gravitational instability have a characteristic temperature below 100 K, while the core-accretion circumplanetary discs are hot, with temperatures even greater than 1000 K when embedded in massive, optically thick protoplanetary discs. We explain how this difference can be understood as the natural result of the different formation mechanisms. We argue that the different temperatures should persist up to the point when a full-fledged gas giant forms via disc instability; hence, our result provides a convenient criterion for observations to distinguish between the two main formation scenarios by measuring the bulk temperature in the planet vicinity.
Cosmic clocks: a tight radius-velocity relationship for H I-selected galaxies
NASA Astrophysics Data System (ADS)
Meurer, Gerhardt R.; Obreschkow, Danail; Wong, O. Ivy; Zheng, Zheng; Audcent-Ross, Fiona M.; Hanish, D. J.
2018-05-01
H I-selected galaxies obey a linear relationship between their maximum detected radius Rmax and rotational velocity. This result covers measurements in the optical, ultraviolet, and H I emission in galaxies spanning a factor of 30 in size and velocity, from small dwarf irregulars to the largest spirals. Hence, galaxies behave as clocks, rotating once a Gyr at the very outskirts of their discs. Observations of a large optically selected sample are consistent, implying this relationship is generic to disc galaxies in the low redshift Universe. A linear radius-velocity relationship is expected from simple models of galaxy formation and evolution. The total mass within Rmax has collapsed by a factor of 37 compared to the present mean density of the Universe. Adopting standard assumptions, we find a mean halo spin parameter λ in the range 0.020-0.035. The dispersion in λ, 0.16 dex, is smaller than expected from simulations. This may be due to the biases in our selection of disc galaxies rather than all haloes. The estimated mass densities of stars and atomic gas at Rmax are similar (˜0.5 M⊙ pc-2), indicating outer discs are highly evolved. The gas consumption and stellar population build time-scales are hundreds of Gyr, hence star formation is not driving the current evolution of outer discs. The estimated ratio between Rmax and disc scalelength is consistent with long-standing predictions from monolithic collapse models. Hence, it remains unclear whether disc extent results from continual accretion, a rapid initial collapse, secular evolution, or a combination thereof.
IRAS 22150+6109 - a young B-type star with a large disc
NASA Astrophysics Data System (ADS)
Zakhozhay, Olga V.; Miroshnichenko, Anatoly S.; Kuratov, Kenesken S.; Zakhozhay, Vladimir A.; Khokhlov, Serik A.; Zharikov, Sergey V.; Manset, Nadine
2018-06-01
We present the results of a spectroscopic analysis and spectral energy distribution (SED) modelling of the optical counterpart of the infrared source IRAS 22150+6109. The source was suggested to be a Herbig Be star located in the star-forming region L 1188. Absorption lines in the optical spectrum indicate a spectral type B3, while weak Balmer emission lines reflect the presence of a circumstellar gaseous disc. The star shows no excess radiation in the near-infrared spectral region and a strong excess in the far-infrared that we interpret as radiation from a large disc, the inner edge of which is located very far from the star (550 au) and does not attenuate its radiation. We conclude that IRAS 22150+6109 is an intermediate-mass star that is currently undergoing a short pre-main-sequence evolutionary stage.
Fan, Bao Jian; Wang, Dan Yi; Pasquale, Louis R.; Haines, Jonathan L.
2011-01-01
Purpose. Genetically complex disorders, such as primary open angle glaucoma (POAG), may include highly heritable quantitative traits as part of the overall phenotype, and mapping genes influencing the related quantitative traits may effectively identify genetic risk factors predisposing to the complex disease. Recent studies have identified SNPs associated with optic nerve area and vertical cup-to-disc ratio (VCDR). The purpose of this study was to evaluate the association between these SNPs and POAG in a US Caucasian case-control sample. Methods. Five SNPs previously associated with optic disc area, or VCDR, were genotyped in 539 POAG cases and 336 controls. Genotype data were analyzed for single SNP associations and SNP interactions with VCDR and POAG. Results. SNPs associated with VCDR rs1063192 (CDKN2B) and rs10483727 (SIX1/SIX6) were also associated with POAG (P = 0.0006 and P = 0.0043 for rs1063192 and rs10483727, respectively). rs1063192, associated with smaller VCDR, had a protective effect (odds ratio [OR] = 0.73; 95% confidence interval [CI], 0.58–0.90), whereas rs10483727, associated with larger VCDR, increased POAG risk (OR = 1.33; 95% CI, 1.08–1.65). POAG risk associated with increased VCDR was significantly influenced by the C allele of rs1900004 (ATOH7), associated with increased optic nerve area (P-interaction = 0.025; OR = 1.89; 95% CI, 1.22–2.94). Conclusions. Genetic variants influencing VCDR are associated with POAG in a US Caucasian population. Variants associated with optic nerve area are not independently associated with disease but can influence the effects of VCDR variants suggesting that increased optic disc area can significantly contribute to POAG risk when coupled with risk factors controlling VCDR. PMID:21398277
High-Resolution Imaging of the Optic Nerve and Retina in Optic Nerve Hypoplasia
Pilat, Anastasia; Sibley, Daniel; McLean, Rebecca J.; Proudlock, Frank A.; Gottlob, Irene
2015-01-01
Purpose To investigate the optic nerve and macular morphology in patients with optic nerve hypoplasia (ONH) using spectral-domain optical coherence tomography (SD OCT). Design Prospective, cross-sectional, observational study. Subjects A total of 16 participants with ONH (10 female and 6 male; mean age, 17.2 years; 6 bilateral involvement) and 32 gender-, age-, ethnicity-, and refraction-matched healthy controls. Methods High-resolution SD OCT (Copernicus [Optopol Technology S.A., Zawiercie, Poland], 3 μm resolution) and handheld SD OCT (Bioptigen Inc [Research Triangle Park, NC], 2.6 μm resolution) devices were used to acquire horizontal scans through the center of the optic disc and macula. Main Outcome Measures Horizontal optic disc/cup and rim diameters, cup depth, peripapillary retinal nerve fiber layer (RNFL), and thickness of individual retinal layers in participants with ONH and in controls. Results Patients with ONH had significantly smaller discs (P < 0.03 and P < 0.001 compared with unaffected eye and healthy controls, respectively), horizontal cup diameter (P < 0.02 for both), and cup depth (P < 0.02 and P < 0.01, respectively). In the macula, significantly thinner RNFL (nasally), ganglion cell layer (GCL) (nasally and temporally), inner plexiform layer (IPL) (nasally), outer nuclear layer (ONL) (nasally), and inner segment (centrally and temporally) were found in patients with ONH compared with the control group (P < 0.05 for all comparisons). Continuation of significantly thicker GCL, IPL, and outer plexiform layer in the central retinal area (i.e., foveal hypoplasia) was found in more than 80% of patients with ONH. Clinically unaffected fellow eyes of patients with ONH showed mild features of underdevelopment. Visual acuity and presence of septo-optic dysplasia were associated with changes in GCL and IPL. Sensitivity and specificity for the detection of ONH based on disc and retinal optical coherence tomography (OCT) parameters were >80%. Conclusions Our study provides evidence of retinal changes in ONH. In addition to thinning of retina layers mainly involving the RNFL and GCL, signs reminiscent of foveal hypoplasia were observed in patients with ONH. Optic nerve and foveal parameters measured using OCT showed high sensitivity and specificity for detecting ONH, demonstrating their useful for clinical diagnosis. PMID:25939636
Optical Coherence Tomography in Glaucoma
NASA Astrophysics Data System (ADS)
Berisha, Fatmire; Hoffmann, Esther M.; Pfeiffer, Norbert
Retinal nerve fiber layer (RNFL) thinning and optic nerve head cupping are key diagnostic features of glaucomatous optic neuropathy. The higher resolution of the recently introduced SD-OCT offers enhanced visualization and improved segmentation of the retinal layers, providing a higher accuracy in identification of subtle changes of the optic disc and RNFL thinning associated with glaucoma.
Optics for Processes, Products and Metrology
NASA Astrophysics Data System (ADS)
Mather, George
1999-04-01
Optical physics has a variety of applications in industry, including process inspection, coatings development, vision instrumentation, spectroscopy, and many others. Optics has been used extensively in the design of solar energy collection systems and coatings, for example. Also, with the availability of good CCD cameras and fast computers, it has become possible to develop real-time inspection and metrology devices that can accommodate the high throughputs encountered in modern production processes. More recently, developments in moiré interferometry show great promise for applications in the basic metals and electronics industries. The talk will illustrate applications of optics by discussing process inspection techniques for defect detection, part dimensioning, birefringence measurement, and the analysis of optical coatings in the automotive, glass, and optical disc industries. In particular, examples of optical techniques for the quality control of CD-R, MO, and CD-RW discs will be presented. In addition, the application of optical concepts to solar energy collector design and to metrology by moiré techniques will be discussed. Finally, some of the modern techniques and instruments used for qualitative and quantitative material analysis will be presented.
Automatic classification of pathological myopia in retinal fundus images using PAMELA
NASA Astrophysics Data System (ADS)
Liu, Jiang; Wong, Damon W. K.; Tan, Ngan Meng; Zhang, Zhuo; Lu, Shijian; Lim, Joo Hwee; Li, Huiqi; Saw, Seang Mei; Tong, Louis; Wong, Tien Yin
2010-03-01
Pathological myopia is the seventh leading cause of blindness. We introduce a framework based on PAMELA (PAthological Myopia dEtection through peripapilLary Atrophy) for the detection of pathological myopia from fundus images. The framework consists of a pre-processing stage which extracts a region of interest centered on the optic disc. Subsequently, three analysis modules focus on detecting specific visual indicators. The optic disc tilt ratio module gives a measure of the axial elongation of the eye through inference from the deformation of the optic disc. In the texturebased ROI assessment module, contextual knowledge is used to demarcate the ROI into four distinct, clinically-relevant zones in which information from an entropy transform of the ROI is analyzed and metrics generated. In particular, the preferential appearance of peripapillary atrophy (PPA) in the temporal zone compared to the nasal zone is utilized by calculating ratios of the metrics. The PPA detection module obtains an outer boundary through a level-set method, and subtracts this region against the optic disc boundary. Temporal and nasal zones are obtained from the remnants to generate associated hue and color values. The outputs of the three modules are used as in a SVM model to determine the presence of pathological myopia in a retinal fundus image. Using images from the Singapore Eye Research Institute, the proposed framework reported an optimized accuracy of 90% and a sensitivity and specificity of 0.85 and 0.95 respectively, indicating promise for the use of the proposed system as a screening tool for pathological myopia.
Polishing mechanism of light-initiated dental composite: Geometric optics approach.
Chiang, Yu-Chih; Lai, Eddie Hsiang-Hua; Kunzelmann, Karl-Heinz
2016-12-01
For light-initiated dental hybrid composites, reinforcing particles are much stiffer than the matrix, which makes the surface rugged after inadequate polish and favors bacterial adhesion and biofilm redevelopment. The aim of the study was to investigate the polishing mechanism via the geometric optics approach. We defined the polishing abilities of six instruments using the obtained gloss values through the geometric optics approach (micro-Tri-gloss with 20°, 60°, and 85° measurement angles). The surface texture was validated using a field emission scanning electron microscope (FE-SEM). Based on the gloss values, we sorted polishing tools into three abrasive levels, and proposed polishing sequences to test the hypothesis that similar abrasive levels would leave equivalent gloss levels on dental composites. The three proposed, tested polishing sequences included: S1, Sof-Lex XT coarse disc, Sof-Lex XT fine disc, and OccluBrush; S2, Sof-Lex XT coarse disc, Prisma Gloss polishing paste, and OccluBrush; and S3, Sof-Lex XT coarse disc, Enhance finishing cups, and OccluBrush. S1 demonstrated significantly higher surface gloss than the other procedures (p < 0.05). The surface textures (FE-SEM micrographs) correlated well with the obtained gloss values. Nominally similar abrasive abilities did not result in equivalent polish levels, indicating that the polishing tools must be evaluated and cannot be judged based on their compositions or abrasive sizes. The geometric optic approach is an efficient and nondestructive method to characterize the polished surface of dental composites. Copyright © 2015. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Muramatsu, Chisako; Nakagawa, Toshiaki; Sawada, Akira; Hatanaka, Yuji; Yamamoto, Tetsuya; Fujita, Hiroshi
2011-09-01
Early diagnosis of glaucoma, which is the second leading cause of blindness in the world, can halt or slow the progression of the disease. We propose an automated method for analyzing the optic disc and measuring the cup-to-disc ratio (CDR) on stereo retinal fundus images to improve ophthalmologists' diagnostic efficiency and potentially reduce the variation on the CDR measurement. The method was developed using 80 retinal fundus image pairs, including 25 glaucomatous, and 55 nonglaucomatous eyes, obtained at our institution. A disc region was segmented using the active contour method with the brightness and edge information. The segmentation of a cup region was performed using a depth map of the optic disc, which was reconstructed on the basis of the stereo disparity. The CDRs were measured and compared with those determined using the manual segmentation results by an expert ophthalmologist. The method was applied to a new database which consisted of 98 stereo image pairs including 60 and 30 pairs with and without signs of glaucoma, respectively. Using the CDRs, an area under the receiver operating characteristic curve of 0.90 was obtained for classification of the glaucomatous and nonglaucomatous eyes. The result indicates potential usefulness of the automated determination of CDRs for the diagnosis of glaucoma.
Chen, Binyao; Gao, Enting; Chen, Haoyu; Yang, Jianling; Shi, Fei; Zheng, Ce; Zhu, Weifang; Xiang, Dehui; Chen, Xinjian; Zhang, Mingzhi
2016-01-01
To investigate the profile and determinants of retinal optical intensity in normal subjects using 3D spectral domain optical coherence tomography (SD OCT). A total of 231 eyes from 231 healthy subjects ranging in age from 18 to 80 years were included and underwent a 3D OCT scan. Forty-four eyes were randomly chosen to be scanned by two operators for reproducibility analysis. Distribution of optical intensity of each layer and regions specified by the Early Treatment of Diabetic Retinopathy Study (ETDRS) were investigated by analyzing the OCT raw data with our automatic graph-based algorithm. Univariate and multivariate analyses were performed between retinal optical intensity and sex, age, height, weight, spherical equivalent (SE), axial length, image quality, disc area and rim/disc area ratio (R/D area ratio). For optical intensity measurements, the intraclass correlation coefficient of each layer ranged from 0.815 to 0.941, indicating good reproducibility. Optical intensity was lowest in the central area of retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, inner nuclear layer, outer plexiform layer and photoreceptor layer, except for the retinal pigment epithelium (RPE). Optical intensity was positively correlated with image quality in all retinal layers (0.553<β<0.851, p<0.01), and negatively correlated with age in most retinal layers (-0.362<β<-0.179, p<0.01), except for the RPE (β = 0.456, p<0.01), outer nuclear layer and photoreceptor layer (p>0.05). There was no relationship between retinal optical intensity and sex, height, weight, SE, axial length, disc area and R/D area ratio. There was a specific pattern of distribution of retinal optical intensity in different regions. The optical intensity was affected by image quality and age. Image quality can be used as a reference for normalization. The effect of age needs to be taken into consideration when using OCT for diagnosis.
Czugala, Monika; Gorkin, Robert; Phelan, Thomas; Gaughran, Jennifer; Curto, Vincenzo Fabio; Ducrée, Jens; Diamond, Dermot; Benito-Lopez, Fernando
2012-12-07
This work describes the first use of a wireless paired emitter detector diode device (PEDD) as an optical sensor for water quality monitoring in a lab-on-a-disc device. The microfluidic platform, based on an ionogel sensing area combined with a low-cost optical sensor, is applied for quantitative pH and qualitative turbidity monitoring of water samples at point-of-need. The autonomous capabilities of the PEDD system, combined with the portability and wireless communication of the full device, provide the flexibility needed for on-site water testing. Water samples from local fresh and brackish sources were successfully analysed using the device, showing very good correlation with standard bench-top systems.
Optic disc drusen: understanding an old problem from a new perspective.
Hamann, Steffen; Malmqvist, Lasse; Costello, Fiona
2018-04-16
Optic disc drusen (ODD) are acellular deposits located in the optic nerve head of up to 2.4% of the population. They may develop as by-products of impaired axonal metabolism in genetically predisposed individuals, in whom a narrow scleral canal is hypothesized to play a role. Although ODD are often considered as benign innocent bystanders, recognized as part of a routine ophthalmological examination, the vast majority of patients with ODD have visual field defects. Optic disc drusen (ODD)-associated complications with severe visual loss, most often due to anterior ischaemic optic neuropathy, are also known to occur. There are no treatments available to prevent or ameliorate the vision loss caused by ODD. In children, the ODD are usually uncalcified and buried within the optic nerve head tissue. In these cases, the condition can be difficult to diagnose, as it often resembles a papilloedema with optic nerve head swelling caused by raised intracranial pressure. During the teenage years, the ODD progressively become more calcified and probably also larger, which allow them to be visible on ophthalmoscopy. With the advent and proper utilization of high-resolution modalities of optical coherence tomography (OCT), it has now become possible to detect even the smallest and most deeply located ODD. This allows for ODD detection at a much earlier developmental stage than has previously been possible and enhances the possibilities of research in underlying mechanisms. A review of the literature on ODD was conducted using the PUBMED database. The review focuses on the current knowledge regarding pathogenesis, diagnostics, clinical disease-tracking methodologies, structure-function relationships and treatment strategies of ODD. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Electrowetting-Based Variable-Focus Lens for Miniature Systems
NASA Astrophysics Data System (ADS)
Hendriks, B. H. W.; Kuiper, S.; van As, M. A. J.; et al.
The meniscus between two immiscible liquids of different refractive indices can be used as a lens. A change in curvature of this meniscus by electrostatic control of the solid/liquid interfacial tension leads to a change in focal distance. It is demonstrated that two liquids in a tube form a self-centred variable-focus lens. The optical properties of this lens were investigated experimentally. We designed and constructed a miniature camera module based on this variable lens suitable for mobile applications. Furthermore, the liquid lens was applied in a Blu-ray Disc optical recording system to enable dual layer disc reading/writing.
Optic disc laceration with combined retinal artery and vein occlusion following penetrating injury.
Lee, Mun-Wai; Lee, Shu-Yen; Ong, Sze-Guan
2007-07-01
Ocular trauma is a major cause of unilateral blindness and male adults in the working age group have been found to have higher rates of ocular injury. A case of a work-related penetrating ocular trauma with an intraocular foreign body causing an optic disc laceration and consequently a combined retinal arterial and venous occlusion is presented. The patient did not recover useful vision despite early surgical intervention. This case highlights an unusual sequelae following penetrating ocular trauma as well as the importance of safety eyewear for individuals in high-risk occupations.
Modelling the multiwavelength emission of Ultraluminous X-ray sources accreting above Eddington
NASA Astrophysics Data System (ADS)
Ambrosi, E.; Zampieri, L.
2017-10-01
Understanding ULXs requires a comprehensive modelling of their multiwavelength emission properties. We compute the optical-through-X-ray emission of ULXs assuming that they are binary systems with stellar-mass or massive-stellar Black Holes and considering the possibility that a non-standard disc sets in when the mass transfer rate (\\dot{M}) becomes highly super-Eddington. The emission model is applied to self-consistent simulations of ULX binaries. We compare our color-magnitude diagrams (CMDs) with those in the literature and find significant differences in the post main sequence evolution. When the donor is on the main-sequence and \\dot{M} is mildly super-Eddington, the behaviour of the system is similar to that found in previous investigations. However, when the donor star leaves the main-sequence and \\dot{M} becomes highly super-Eddington, the optical luminosity of the system is systematically larger and the colours show a markedly different evolution. The emission properties depend on the variable shielding of the outer disc and donor induced by the changing inner disc structure. We determine also the effects caused by the onset of a strong optically thick outflow. CMDs in various photometric systems are compared to the observed properties of the optical counterparts of several ULXs, obtaining updated constraints on their donor mass and accretion rate.
Automatic non-proliferative diabetic retinopathy screening system based on color fundus image.
Xiao, Zhitao; Zhang, Xinpeng; Geng, Lei; Zhang, Fang; Wu, Jun; Tong, Jun; Ogunbona, Philip O; Shan, Chunyan
2017-10-26
Non-proliferative diabetic retinopathy is the early stage of diabetic retinopathy. Automatic detection of non-proliferative diabetic retinopathy is significant for clinical diagnosis, early screening and course progression of patients. This paper introduces the design and implementation of an automatic system for screening non-proliferative diabetic retinopathy based on color fundus images. Firstly, the fundus structures, including blood vessels, optic disc and macula, are extracted and located, respectively. In particular, a new optic disc localization method using parabolic fitting is proposed based on the physiological structure characteristics of optic disc and blood vessels. Then, early lesions, such as microaneurysms, hemorrhages and hard exudates, are detected based on their respective characteristics. An equivalent optical model simulating human eyes is designed based on the anatomical structure of retina. Main structures and early lesions are reconstructed in the 3D space for better visualization. Finally, the severity of each image is evaluated based on the international criteria of diabetic retinopathy. The system has been tested on public databases and images from hospitals. Experimental results demonstrate that the proposed system achieves high accuracy for main structures and early lesions detection. The results of severity classification for non-proliferative diabetic retinopathy are also accurate and suitable. Our system can assist ophthalmologists for clinical diagnosis, automatic screening and course progression of patients.
Kim, Min Kyung; Kim, Ungsoo Samuel
2016-08-01
We evaluated fundus and fluorescein angiography (FAG) findings and characteristics that can help distinguish nonarteritic anterior ischemic optic neuropathy (NAION) from optic neuritis (ON). Twenty-three NAION patients and 17 ON with disc swelling patients were enrolled in this study. We performed fundus photography and FAG. The disc-swelling pattern, hyperemia grade, presence of splinter hemorrhages, cotton-wool spots, artery/vein ratio and degree of focal telangiectasia were investigated. The FAG findings for each patient were compared with respect to the following features: the pattern of disc leakage in the early phase, arteriovenous (artery/vein) transit time (second), and the presence and pattern of the filling delay. Cotton-wool spots, focal telangiectasia, and venous congestion were more common in the affected eyes of NAION patients. Upon FAG, 76.5% of the patients in the ON group exhibited normal choroidal circulation. However, 56.5% of patients in the NAION group demonstrated abnormal filling defects, such as peripapillary, generalized, or watershed zone filling delays. Fundus findings, including cotton-wool spots, focal telangiectasia, and venous congestion in the affected eye, may be clues that can be used to diagnose NAION. In addition, choroidal insufficiencies on FAG could be also helpful in differentiating NAION from ON.
In situ measurements of thin films in bovine serum lubricated contacts using optical interferometry.
Vrbka, Martin; Křupka, Ivan; Hartl, Martin; Návrat, Tomáš; Gallo, Jiří; Galandáková, Adéla
2014-02-01
The aim of this study is to consider the relevance of in situ measurements of bovine serum film thickness in the optical test device that could be related to the function of the artificial hip joint. It is mainly focussed on the effect of the hydrophobicity or hydrophilicity of the transparent surface and the effect of its geometry. Film thickness measurements were performed using ball-on-disc and lens-on-disc configurations of optical test device as a function of time. Chromatic interferograms were recorded with a high-speed complementary metal-oxide semiconductor digital camera and evaluated with thin film colorimetric interferometry. It was clarified that a chromium layer covering the glass disc has a hydrophobic behaviour which supports the adsorption of proteins contained in the bovine serum solution, thereby a thicker lubricating film is formed. On the contrary, the protein film formation was not observed when the disc was covered with a silica layer having a hydrophilic behaviour. In this case, a very thin lubricating film was formed only due to the hydrodynamic effect. Metal and ceramic balls have no substantial effect on lubricant film formation although their contact surfaces have relatively different wettability. It was confirmed that conformity of contacting surfaces and kinematic conditions has fundamental effect on bovine serum film formation. In the ball-on-disc configuration, the lubricant film is formed predominantly due to protein aggregations, which pass through the contact zone and increase the film thickness. In the more conformal ball-on-lens configuration, the lubricant film is formed predominantly due to hydrodynamic effect, thereby the film thickness is kept constant during measurement.
NASA Astrophysics Data System (ADS)
Higginbottom, Nick; Knigge, Christian; Long, Knox S.; Matthews, James H.; Sim, Stuart A.; Hewitt, Henrietta A.
2018-06-01
Essentially all low-mass X-ray binaries (LMXBs) in the soft state appear to drive powerful equatorial disc winds. A simple mechanism for driving such outflows involves X-ray heating of the top of the disc atmosphere to the Compton temperature. Beyond the Compton radius, the thermal speed exceeds the escape velocity, and mass loss is inevitable. Here, we present the first coupled radiation-hydrodynamic simulation of such thermally-driven disc winds. The main advance over previous modelling efforts is that the frequency-dependent attenuation of the irradiating SED is taken into account. We can therefore relax the approximation that the wind is optically thin throughout which is unlikely to hold in the crucial acceleration zone of the flow. The main remaining limitations of our simulations are connected to our treatment of optically thick regions. Adopting parameters representative of the wind-driving LMXB GRO J1655-40, our radiation-hydrodynamic model yields a mass-loss rate that is ≃ 5 × lower than that suggested by pure hydrodynamic, optically thin models. This outflow rate still represents more than twice the accretion rate and agrees well with the mass-loss rate inferred from Chandra/HETG observations of GRO J1655-40 at a time when the system had a similar luminosity to that adopted in our simulations. The Fe XXV and Fe XXVI Lyman {α } absorption line profiles observed in this state are slightly stronger than those predicted by our simulations but the qualitative agreement between observed and simulated outflow properties means that thermal driving is a viable mechanism for powering the disc winds seen in soft-state LMXBs.
DZ Chamaeleontis: a bona fide photoevaporating disc
NASA Astrophysics Data System (ADS)
Canovas, H.; Montesinos, B.; Schreiber, M. R.; Cieza, L. A.; Eiroa, C.; Meeus, G.; de Boer, J.; Ménard, F.; Wahhaj, Z.; Riviere-Marichalar, P.; Olofsson, J.; Garufi, A.; Rebollido, I.; van Holstein, R. G.; Caceres, C.; Hardy, A.; Villaver, E.
2018-02-01
Context. DZ Cha is a weak-lined T Tauri star (WTTS) surrounded by a bright protoplanetary disc with evidence of inner disc clearing. Its narrow Hα line and infrared spectral energy distribution suggest that DZ Cha may be a photoevaporating disc. Aims: We aim to analyse the DZ Cha star + disc system to identify the mechanism driving the evolution of this object. Methods: We have analysed three epochs of high resolution optical spectroscopy, photometry from the UV up to the sub-mm regime, infrared spectroscopy, and J-band imaging polarimetry observations of DZ Cha. Results: Combining our analysis with previous studies we find no signatures of accretion in the Hα line profile in nine epochs covering a time baseline of 20 yr. The optical spectra are dominated by chromospheric emission lines, but they also show emission from the forbidden lines [SII] 4068 and [OI] 6300Å that indicate a disc outflow. The polarized images reveal a dust depleted cavity of 7 au in radius and two spiral-like features, and we derive a disc dust mass limit of Mdust< 3 MEarth from the sub-mm photometry. No stellar (M⋆> 80 MJup) companions are detected down to 0.̋07 ( 8 au, projected). Conclusions: The negligible accretion rate, small cavity, and forbidden line emission strongly suggests that DZ Cha is currently at the initial stages of disc clearing by photoevaporation. At this point the inner disc has drained and the inner wall of the truncated outer disc is directly exposed to the stellar radiation. We argue that other mechanisms like planet formation or binarity cannot explain the observed properties of DZ Cha. The scarcity of objects like this one is in line with the dispersal timescale (≲105 yr) predicted by this theory. DZ Cha is therefore an ideal target to study the initial stages of photoevaporation. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere under ESO programme 097.C-0536. Based on data obtained from the ESO Science Archive Facility under request number 250112.
NASA Astrophysics Data System (ADS)
Iftimia, Nicusor; Peterson, Gary; Chang, Ernest W.; Maguluri, Gopi; Fox, William; Rajadhyaksha, Milind
2016-01-01
We present a combined reflectance confocal microscopy (RCM) and optical coherence tomography (OCT) approach, integrated within a single optical layout, for diagnosis of basal cell carcinomas (BCCs) and delineation of margins. While RCM imaging detects BCC presence (diagnoses) and its lateral spreading (margins) with measured resolution of ˜1 μm, OCT imaging delineates BCC depth spreading (margins) with resolution of ˜7 μm. When delineating margins in 20 specimens of superficial and nodular BCCs, depth could be reliably determined down to ˜600 μm, and agreement with histology was within about ±50 μm.
Interactive Visualization of a Thin Disc around a Schwarzschild Black Hole
ERIC Educational Resources Information Center
Muller, Thomas; Frauendiener, Jorg
2012-01-01
In a first course in general relativity, the Schwarzschild spacetime is the most discussed analytic solution to Einstein's field equations. Unfortunately, there is rarely enough time to study the optical consequences of the bending of light for some advanced examples. In this paper, we present how the visual appearance of a thin disc around a…
Bilateral Glaucomatous Optic Neuropathy Caused by Eye Rubbing.
Savastano, Alfonso; Savastano, Maria Cristina; Carlomusto, Laura; Savastano, Silvio
2015-01-01
In this report, we describe a particular condition of a 52-year-old man who showed advanced bilateral glaucomatous-like optic disc damage, even though the intraocular pressure resulted normal during all examinations performed. Visual field test, steady-state pattern electroretinogram, retinal nerve fiber layer and retinal tomographic evaluations were performed to evaluate the optic disc damage. Over a 4-year observational period, his visual acuity decreased to 12/20 in the right eye and counting fingers in the left eye. Visual fields were severely compromised, and intraocular pressure values were not superior to 14 mm Hg during routine examinations. An accurate anamnesis and the suspicion of this disease represent a crucial aspect to establish the correct diagnosis. In fact, our patient strongly rubbed his eyes for more than 10 h per day. Recurrent and continuous eye rubbing can induce progressive optic neuropathy, causing severe visual field damage similar to the pathology of advanced glaucoma.
Three-dimensional spectral domain optical coherence tomography in X linked foveal retinoschisis
Saxena, Sandeep; Manisha; Meyer, Carsten H
2013-01-01
Spectral domain optical coherence tomography (SD-OCT) was performed in two cases of bilateral X linked foveal retinoschisis of different age groups. On fundus examination spoke wheel and honeycomb pattern of cysts were observed along with retinal nerve fibre layer (RNFL) defects. On SD-OCT, schisis was observed in the outer plexiform layer. External limiting membrane disruption was observed in the subfoveal area, along with disruption of outer nuclear layer (ONL) and inner–outer segment junction. Elevation of ONL due to tractional pull of central palisade was a novel observation. Retinoschisis extended beyond the optic disc up to the nasal region. Extracted RNFL tomogram presented an unprecedented visualisation of schisis along 360° of the optic disc. Tractional elevation in the foveal area and schisis involving nasal region, not observed upon clinical examination, was highlighted on SD-OCT. This investigative modality is an important adjunct in the assessment of foveal retinoschisis. PMID:23563673
Lenticular astigmatism in tilted disc syndrome.
Gündüz, Abuzer; Evereklioglu, Cem; Er, Hamdi; Hepşen, Ibrahim F
2002-10-01
To evaluate whether an abnormal optic disc shape in patients with tilted disc syndrome (TDS) is associated with an abnormal configuration of the crystalline lens measured as lenticular astigmatism. Department of Ophthalmology, Inönü University Medical Faculty, Turgut Ozal Medical Center, Malatya, Turkey. This cross-sectional masked case-control study comprised 32 eyes of 32 patients with established TDS (13 men, 19 women; mean age 21.31 years +/- 7.05 [SD]) and 20 age- and sex-matched healthy control subjects (8 men, 12 women; mean age 22.65 +/- 7.11 years) with a comparable amount of myopic astigmatism (spherical equivalent) without TDS. The optic disc was morphometrically analyzed by planimetric evaluation of optic disc photographs. The total refractive and keratometric corneal astigmatism was obtained, and lenticular astigmatism was calculated by vector analysis. The Mann-Whitney U test was used for statistical analysis; 1 eye of each patient was evaluated in both groups. A P value less than 0.05 was considered statistically significant. The mean spherical equivalent refraction was comparable in TDS patients (-4.73 +/- 1.12 diopters [D]) and controls (-4.28 +/- 1.29 D) (P =.210). The mean total astigmatism was higher in TDS patients (-2.96 +/- 1.04 D) than in the controls (-2.51 +/- 1.09 D), but the difference was not significant (P =.151). The mean corneal astigmatism was comparable in TDS patients (-2.07 +/- 0.83 D) and controls (-2.28 +/- 0.87 D) (P =.454), but the calculated mean lenticular astigmatism was significantly higher in TDS patients (-1.31 +/- 0.98 D and -0.20 +/- 0.35 D, respectively) (P <.001). Twenty-nine of 32 TDS patients (90.6%) had lenticular astigmatism; in 16 (50%), it was greater than -1.00 D. Lenticular astigmatism was present in 7 controls (35%); in 2 (10%), it was greater than -1.00 D. The mean keratometry was significantly higher in TDS patients (43.84 +/- 1.06 D) than in the controls (42.75 +/- 1.45 D) (P =.011). Clinically significant lenticular astigmatism was present in TDS patients. If an abnormal optic disc shape is found on ophthalmoscopy, lenticular astigmatism as well as corneal astigmatism should be carefully evaluated to prevent an unsatisfactory refractive outcome, especially in refractive surgery candidates.
Gaasterland, D E; Blackwell, B; Dally, L G; Caprioli, J; Katz, L J; Ederer, F
2001-01-01
An analysis of data from the Advanced Glaucoma Intervention Study (AGIS) has found eyes reported to have partial optic disc rim notching (not to the edge) at baseline to have less risk of subsequent visual field loss than eyes with no notching. Because this is counterintuitive and because classification of notching had not been defined in the AGIS protocol, we have assessed AGIS ophthalmologists interobserver and intraobserver agreement on notching. Fourteen glaucoma subspecialists classified notching in 26 pairs of stereoscopic disc photographs of eyes with mild to severe glaucomatous optic neuropathy. They classified images as showing either no notching, notching not to the edge, or notching to the edge. Several hours later, 10 of them classified the same images a second time. In an analysis of interobserver agreement, of 26 stereoscopic images, a plurality of ophthalmologists classified notching as absent in 9 (35%), as present but not to the edge in 7 (27%), and as present and not to the edge in 10 (38%). All 14 ophthalmologists (100%) agreed on the classification of 7 (27%) of the images, and 13 of the 14 ophthalmologists (93%) agreed on the classification of 4 additional images (15%). Of these 11 images with at least 93% agreement, notching was reported as absent in 3 (27%) and to the edge in 8 (73%). In the remaining 15 images, there was substantial disagreement about whether notching was present and, if so, whether it was to the edge. In an analysis of intraobserver agreement, none of the 10 ophthalmologists who completed the viewing a second time classified all eyes exactly the same as the first time, though 5 ophthalmologists made 4 or fewer reclassifications. Overall, 80% of the original classifications were reproduced on second reading. Of the initial classifications that were not reproduced, slightly more than half were first classified as having notching not to the edge. Without definitions or examples of optic disc rim notching, the glaucoma subspecialists had relatively high intraobserver agreement but were likely to disagree with each other in characterizing the degree of disc rim notching. We recommend development of a standard photographic classification of disc rim notching. The classification should be tested for inter- and intra-observer agreement.
Gaasterland, D E; Blackwell, B; Dally, L G; Caprioli, J; Katz, L J; Ederer, F
2001-01-01
PURPOSE: An analysis of data from the Advanced Glaucoma Intervention Study (AGIS) has found eyes reported to have partial optic disc rim notching (not to the edge) at baseline to have less risk of subsequent visual field loss than eyes with no notching. Because this is counterintuitive and because classification of notching had not been defined in the AGIS protocol, we have assessed AGIS ophthalmologists interobserver and intraobserver agreement on notching. METHODS: Fourteen glaucoma subspecialists classified notching in 26 pairs of stereoscopic disc photographs of eyes with mild to severe glaucomatous optic neuropathy. They classified images as showing either no notching, notching not to the edge, or notching to the edge. Several hours later, 10 of them classified the same images a second time. RESULTS: In an analysis of interobserver agreement, of 26 stereoscopic images, a plurality of ophthalmologists classified notching as absent in 9 (35%), as present but not to the edge in 7 (27%), and as present and not to the edge in 10 (38%). All 14 ophthalmologists (100%) agreed on the classification of 7 (27%) of the images, and 13 of the 14 ophthalmologists (93%) agreed on the classification of 4 additional images (15%). Of these 11 images with at least 93% agreement, notching was reported as absent in 3 (27%) and to the edge in 8 (73%). In the remaining 15 images, there was substantial disagreement about whether notching was present and, if so, whether it was to the edge. In an analysis of intraobserver agreement, none of the 10 ophthalmologists who completed the viewing a second time classified all eyes exactly the same as the first time, though 5 ophthalmologists made 4 or fewer reclassifications. Overall, 80% of the original classifications were reproduced on second reading. Of the initial classifications that were not reproduced, slightly more than half were first classified as having notching not to the edge. CONCLUSION: Without definitions or examples of optic disc rim notching, the glaucoma subspecialists had relatively high intraobserver agreement but were likely to disagree with each other in characterizing the degree of disc rim notching. We recommend development of a standard photographic classification of disc rim notching. The classification should be tested for inter- and intra-observer agreement. PMID:11797305
Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa
2014-01-01
The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss.
Hata, Masayuki; Miyamoto, Kazuaki; Oishi, Akio; Kimura, Yugo; Nakagawa, Satoko; Horii, Takahiro; Yoshimura, Nagahisa
2014-01-01
Background The retinal nerve fiber layer thickness (RNFLT) in patients with optic disc swelling of different etiologies was compared using scanning laser polarimetry (SLP) and spectral-domain optical coherence tomography (OCT). Methods Forty-seven patients with optic disc swelling participated in the cross-sectional study. Both GDx SLP (enhanced corneal compensation) and Spectralis spectral-domain OCT measurements of RNFLT were made in 19 eyes with papilledema (PE), ten eyes with optic neuritis (ON), and 18 eyes with nonarteritic anterior ischemic optic neuropathy (NAION) at the neuro-ophthalmology clinic at Kyoto University Hospital. Differences in SLP (SLP-RNFLT) and OCT (OCT-RNFLT) measurements among different etiologies were investigated. Results No statistical differences in average OCT-RNFLT among PE, ON, and NAION patients were noted. Average SLP-RNFLT in NAION patients was smaller than in PE (P<0.01) or ON (P=0.02) patients. When RNFLT in each retinal quadrant was compared, no difference among etiologies was noted on OCT, but on SLP, the superior quadrant was thinner in NAION than in PE (P<0.001) or ON (P=0.001) patients. Compared with age-adjusted normative data of SLP-RNFLT, average SLP-RNFLT in PE (P<0.01) and ON (P<0.01) patients was greater. Superior SLP-RNFLT in NAION patients was smaller (P=0.026). The ratio of average SLP-RNFLT to average OCT-RNFLT was smaller in NAION than in PE (P=0.001) patients. Conclusion In the setting of RNFL thickening, despite increased light retardance in PE and ON eyes, SLP revealed that NAION eyes have less retardance, possibly associated with ischemic axonal loss. PMID:24379653
Optic nerve head cupping in glaucomatous and non-glaucomatous optic neuropathy.
Fard, Masoud Aghsaei; Moghimi, Sasan; Sahraian, Alireza; Ritch, Robert
2018-05-23
Enlargement of optic disc cupping is seen both in glaucoma and in neurological disorders. We used enhanced depth imaging with spectral-domain optical coherence tomography to differentiate glaucoma from non-glaucomatous optic neuropathy. The optic discs were scanned in this prospective comparative study, and the lamina cribrosa (LC) thickness and anterior laminar depth (ALD) in the central, superior and inferior optic nerve head, and peripapillary choroidal thicknesses, were measured. There were 31 eyes of 31 patients with severe glaucoma and 33 eyes of 19 patients with non-glaucomatous cupping. Eyes of 29 healthy controls were also enrolled. There was no significant difference in the cup-to-disc ratio and in the average peripapillary nerve fibre layer thickness between the glaucoma and non-glaucomatous cupping groups (p>0.99). The average peripapillary choroidal thickness was thinner in glaucoma eyes than in the control eyes after adjusting for age and axial length. Glaucomatous and non-glaucomatous eyes had greater ALD and thinner LC than the control eyes (p<0.001 for both). ALDs of glaucoma eyes were deeper than non-glaucomatous eyes (p=0.01 for central ALD) when age, axial length and peripapillary choroidal thickness were included in the linear mixed model. Prelaminar thickness and LC thickness of glaucoma eyes were not different from non-glaucomatous eyes after adjusting. Deeper ALD was observed in glaucoma than non-glaucomatous cupping after adjusting for choroidal thickness. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Peripapillary Retinoschisis in Glaucomatous Eyes
Lee, Eun Ji; Kim, Tae-Woo; Kim, Mijin; Choi, Yun Jeong
2014-01-01
Purpose To investigate the structural and clinical characteristics of peripapillary retinoschisis observed in glaucomatous eyes using spectral-domain optical coherence tomography (SD-OCT). Methods Circumpapillary retinal nerve fiber layer (cpRNFL) and macular cross-hair SD-OCT scans and infrared fundus images of the glaucoma patients from the Investigating Glaucoma Progression Study (IGPS) and healthy volunteers were reviewed. Optic disc images obtained using enhanced depth imaging (EDI) SD-OCT were also evaluated. The structural characteristics and clinical course of the retinoschisis associated with glaucoma were investigated. Results Twenty-five retinoschisis areas were found in 22 of the 372 patients (5.9%) included in the IGPS, and in 1 area in 1 of 187 healthy control subjects (0.5%). In the 22 glaucomatous eyes with retinoschisis, the schisis was attached to the optic disc and overlapped with the retinal nerve fiber layer (RNFL) defect. The RNFL was the layer most commonly affected by the retinoschisis, either alone or together with other deeper layers. Acquired optic disc pit was identified in 8 eyes on disc photography and/or B-scan images obtained by EDI SD-OCT. Spontaneous resolution of this condition was observed in nine eyes. No retinal detachment or macular involvement of the retinoschisis was observed in any of the eyes. Multivariate analysis showed a significant influence of a higher intraocular pressure at SD-OCT scanning on the presence of retinoschisis (Odds ratio = 1.418, P = 0.001). Conclusions The present study investigated 22 cases of peripapillary retinoschisis in glaucomatous eyes. The retinoschisis was attached to the optic nerve and topographically correlated with RNFL defect. It often resolved spontaneously without causing severe visual disturbance. Care should be taken not to overestimate the RNFL thickness in eyes with retinoschisis, and also not to misinterpret the resolution of retinoschisis as a rapid glaucomatous RNFL deterioration. PMID:24587238
Marginal adaptation of ceramic veneers investigated with en face optical coherence tomography
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negruţiu, Meda-Lavinia; Petrescu, Emanuela; Rominu, Mihai; Marcauteanu, Corina; Rominu, Roxana; Hughes, Michael; Bradu, Adrian; Dobre, George; Podoleanu, Adrian G.
2009-07-01
The aim of this study was to analyze the quality of marginal adaptation and gap width of Empress veneers using en-face optical coherence tomography. The results prove the necessity of investigating the marginal adaptation after each veneer bonding process.
[Nonarteritic ischemic optic neuropathy animal model and its treatment applications].
Chuman, Hideki
2014-04-01
Nonarteritic ischemic optic neuropathy (NAION) is one of the most common acute unilaterally onset optic nerve diseases. One management problem in terms of NAION is the difficulty of differential diagnosis between NAION and anterior optic neuritis (ON). A second problem is that there is no established treatment for the acute stage of NAION. A third problem is that there is no preventive treatment for a subsequent attack on the fellow eye, estimated to occur in 15 to 25% of patients with NAION. For differentiation of acute NAION from anterior optic neuritis, we investigated the usefulness of laser speckle flowgraphy (LSFG). In the normal control group, the tissue blood flow did not significantly differ between the right and left eyes. In the NAION group, all 6 patients had 29.5% decreased mean blur rate (MBR), which correlates to optic disc blood flow, of the NAION eye compared with the unaffected eye. In the anterior ON group, all 6 cases had 15.9% increased MBR of the anterior ON eye compared with the unaffected eye. Thus, LSFG showed a difference of the underlying pathophysiology between NAION and anterior ON despite showing disc swelling in both groups and could be useful for differentiating both groups. For the treatment of acute stage of NAION, we tried to reproduce the rodent model of NAION (rNAION) developed by Bernstein and colleagues. To induce rNAION, after the administration of rose bengal(RB) (2.5 mM) into the tail vein of SD rats, the small vessels of the left optic nerve were photoactivated using a 514 nm argon green laser (RB-laser-induction). In the RB-laser-induction eyes, the capillaries within the optic disc were reduced markedly, the optic disc became swollen, and fluorescein angiography showed filling defect in the choroid and the optic disc at an early stage, followed by hyperfluorescence at a late stage. Electrophysiological evaluation revealed that visual evoked potential (VEP) amplitude was significantly decreased but an electroretinogram (ERG) did not show a significant difference either in the b wave or in the oscillatory potentials. The scotopic threshold response (STR) was significantly reduced 3 days after induction. These findings are similar to those of rNAION and indicate that we succeeded in reproducing the rNAION. Histopathologic examination in the acute phase of rNAION, showed acellular NFL swelling anterior to the optic disc. No accumulation of inflammatory cells was noted in several microscopic sections of the optic nerve. In addition, immunochemical staining was negative throughout the retina and optic nerve. These results suggested that the rNAION-induced NFL swelling was not a result of inflammation. In the chronic phase of rNAION, the morphologic retinal changes were apparent in only the retinal ganglion cell(RGC) layer, with a reduction in the number of cells in the RGC layer. Thus, we need to evaluate the degree of the NFL swelling in the acute phase and the following thinning of the NFL in the chronic phase for efficacy of the treatment of rNAION. Therefore, we used optical coherence tomography (OCT) for the objective and quantitative evaluation of the retinal nerve fiber layer (RNFL) thickness around the optic disc changes in rNAION. The second method was to use the STR for the evaluation of the RGC function. The third method was to count the number of surviving RGCs observed and photographed through the fluorescence microscope with the Fluorogold staining. A possible rationale for treatment of NAION is that dilation of the posterior ciliary artery (PCA) increases the blood flow to the optic nerve and could improve the optic nerve function. To clarify the vasodilatory effects of medications, we used in vitro isometric tension recording methods and examined the vasodilatory effects of bevacizumab as an anti-vascular endothelial growth factor (VEGF) antibody, methylprednisolone as a corticosteroid and sodium nitroprusside (SNP, a nitric oxide donor) as a vasodilator on high-K (potassium) solution-induced contraction in isolated rabbit PCA. Bevacizumab did not relax rabbit PCA. Methylprednisolone relaxed rabbit PCA nitric oxide (NO) independently. SNP relaxed rabbit PCA by exogenous NO. On the basis of these results, we selected the following candidates for rNAION treatment: methylprednisolone as the corticosteroid and L-arginine as the NO related agent. Intravenous infusion of methylprednisolone significantly decreased the degree of acute disc edema but did not reduce inner retinal thinning, decrease STR amplitude, or decrease RGC numbers in rNAION. Intravenous infusion of L-arginine after rNAION induction significantly decreased the disc edema at the acute stage and the thinning of the inner retina, reduced the decrease in STR amplitude, and reduced the decrease in RGC numbers during rNAION. These results indicated that L-arginine treatment is effective for reducing the anatomical changes and improving visual function in the acute stage of rNAION. To strengthen the neuroprotective effect for rNAION, we tried treatment using transcorneal electric stimulation (TES). We evaluated the effect using STR and survival RGCs. Decreased amplitude in the STR of the TES group was significantly better preserved than in the control group on the 28th day after treatment. RGC survival in the TES group was significantly larger than in the control group on the 14th and 28th days. The neuroprotective effect of TES was better than that of L-arginine. For preventive treatment of subsequent attack in the fellow eye, we investigated whether pretreatment with L-arginine might reduce the severity of the anatomical changes associated with NAION and preserve the visual function when NAION occurs in the other eye. In the L-arginine pretreated eyes, the disc edema at the acute stage and the thinning of inner retina were significantly decreased, and the decrease of STR amplitude and the decrease in RGC numbers during rNAION were reserved. These results indicate that pretreatment with L-arginine is effective for the reduction of the severity during recurrence in the other eye. We will perform clinical trials in a small series of cases, and if the treatment is effective, we will proceed to multicenter randomized treatment trials. In addition to that, more work needs to be done to discover better treatment options for NAION.
NASA Astrophysics Data System (ADS)
Watson, Linda C.; Martini, Paul; Lisenfeld, Ute; Böker, Torsten; Schinnerer, Eva
2016-01-01
Studying star formation beyond the optical radius of galaxies allows us to test empirical relations in extreme conditions with low average gas density and low molecular fraction. Previous studies discovered galaxies with extended ultraviolet (XUV) discs, which often contain star-forming regions with lower Hα-to-far-UV (FUV) flux ratios compared to inner disc star-forming regions. However, most previous studies lack measurements of molecular gas, which is presumably the component of the interstellar medium out of which stars form. We analysed published CO measurements and upper limits for 15 star-forming regions in the XUV or outer disc of three nearby spiral galaxies and a new CO upper limit from the IRAM (Institut de Radioastronomie Millimétrique) 30 m telescope in one star-forming region at r = 3.4r25 in the XUV disc of NGC 4625. We found that the star-forming regions are in general consistent with the same molecular-hydrogen Kennicutt-Schmidt law that applies within the optical radius, independent of whether we used Hα or FUV as the star formation rate (SFR) tracer. However, a number of the CO detections are significantly offset towards higher SFR surface density for their molecular-hydrogen surface density. Deeper CO data may enable us to use the presence or absence of molecular gas as an evolutionary probe to break the degeneracy between age and stochastic sampling of the initial mass function as the explanation for the low Hα-to-FUV flux ratios in XUV discs.
Miller, N R; Arnold, A C
2015-01-01
Nonarteritic anterior ischaemic optic neuropathy (NAION) is the most common acute optic neuropathy in patients over the age of 50 and is the second most common cause of permanent optic nerve-related visual loss in adults after glaucoma. Patients typically present with acute, painless, unilateral loss of vision associated with a variable visual field defect, a relative afferent pupillary defect, a swollen, hyperaemic optic disc, and one or more flame-shaped peripapillary retinal haemorrhages. The pathogenesis of this condition is unknown, but it occurs primarily in patients with structurally small optic discs that have little or no cup and a variety of underlying vascular disorders that may or may not be known at the time of visual loss. There is no consistently beneficial medical or surgical treatment for the condition, but there are now animal models that allow testing of various potential therapies. About 40% of patients experience spontaneous improvement in visual acuity. Patients in whom NAION occurs in one eye have a 15-19% risk of developing a similar event in the opposite eye over the subsequent 5 years.
Miller, N R; Arnold, A C
2015-01-01
Nonarteritic anterior ischaemic optic neuropathy (NAION) is the most common acute optic neuropathy in patients over the age of 50 and is the second most common cause of permanent optic nerve-related visual loss in adults after glaucoma. Patients typically present with acute, painless, unilateral loss of vision associated with a variable visual field defect, a relative afferent pupillary defect, a swollen, hyperaemic optic disc, and one or more flame-shaped peripapillary retinal haemorrhages. The pathogenesis of this condition is unknown, but it occurs primarily in patients with structurally small optic discs that have little or no cup and a variety of underlying vascular disorders that may or may not be known at the time of visual loss. There is no consistently beneficial medical or surgical treatment for the condition, but there are now animal models that allow testing of various potential therapies. About 40% of patients experience spontaneous improvement in visual acuity. Patients in whom NAION occurs in one eye have a 15–19% risk of developing a similar event in the opposite eye over the subsequent 5 years. PMID:24993324
The transiting dust clumps in the evolved disc of the Sun-like UXor RZ Psc
Kenworthy, Matthew A.; Pepper, Joshua; Rodriguez, Joseph E.; Siverd, Robert J.; Stassun, Keivan G.; Wyatt, Mark C.
2017-01-01
RZ Psc is a young Sun-like star, long associated with the UXor class of variable stars, which is partially or wholly dimmed by dust clumps several times each year. The system has a bright and variable infrared excess, which has been interpreted as evidence that the dimming events are the passage of asteroidal fragments in front of the host star. Here, we present a decade of optical photometry of RZ Psc and take a critical look at the asteroid belt interpretation. We show that the distribution of light curve gradients is non-uniform for deep events, which we interpret as possible evidence for an asteroidal fragment-like clump structure. However, the clumps are very likely seen above a high optical depth midplane, so the disc’s bulk clumpiness is not revealed. While circumstantial evidence suggests an asteroid belt is more plausible than a gas-rich transition disc, the evolutionary status remains uncertain. We suggest that the rarity of Sun-like stars showing disc-related variability may arise because (i) any accretion streams are transparent and/or (ii) turbulence above the inner rim is normally shadowed by a flared outer disc. PMID:28280566
Planet signatures and Size Segregation in Debris Discs
NASA Astrophysics Data System (ADS)
Thébault, Philippe
2014-01-01
The response of a debris disc to a planetary perturber is the result of the complex interplay between gravitational effects, grain collisions and stellar radiation pressure (Stark & Kuchner (2009). We investigate to what extent this response can depart from the pure gravitational case when including grain collisional production and radiation pressure. We use the DyCoSS code (Thébault (2012), designed to study the coupled effect of collisions and dynamics for systems at steady state with one perturbing body. We focus on two outcomes: the 2D surface density profile of the disc+planet system, and the way the Particle Size Distribution (PSD) is spatially segregated within the disc. We consider two set-ups: 1) a narrow ring with an exterior ``shepherding'' planet, and 2) an extended disc in which a planet is embedded. For each case, the planet mass and orbit are explored as free parameters, and an unperturbed ``no-planet'' case is also considered. Another parameter is the disc's collisional activity, as parameterized by its optical depth τ.
Shrot, S; Sayah, A; Berkowitz, F
2017-07-01
To evaluate whether various patterns of bone marrow oedema could be used to discriminate between infection and degenerative change. Seventy patients with imaging features suspicious for discitis and available clinical follow-up were blindly reviewed for vertebral marrow oedema on sagittal short-tau inversion recovery (STIR) images according to the following patterns: I, vertebra oedema is adjacent to the intervertebral space and sharply-marginated; II, vertebral oedema is adjacent to the intervertebral space but not sharply marginated from normal marrow or involves the entire vertebral body; and III, vertebral oedema is distant from the endplate with intervening hypointense marrow signal. Of 45 patients with a clinical diagnosis of discitis, pattern II was the most common oedema pattern (64%). Approximately 20% and 9% of discitis patients showed patterns I and III, respectively. In patients with degenerative changes, 44% patients showed pattern I, 32% showed pattern II, and 24% showed pattern III. Pattern II had a sensitivity, specificity, and positive predictive value of 0.64, 0.68, and 0.78 for diagnosing spine infection, respectively. Although bone marrow oedema in infective discitis most often extends from the disc space and has indistinct margins, the oedema may also have sharp margins or be remote from the involved intervertebral space. Bone marrow oedema patterns of infective discitis overlap with those of degenerative disease and are not sufficiently reliable to exclude infection in cases with magnetic resonance imaging findings suggestive of discitis. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Only marginal alignment of disc galaxies
NASA Astrophysics Data System (ADS)
Andrae, René; Jahnke, Knud
2011-12-01
Testing theories of angular-momentum acquisition of rotationally supported disc galaxies is the key to understanding the formation of this type of galaxies. The tidal-torque theory aims to explain this acquisition process in a cosmological framework and predicts positive autocorrelations of angular-momentum orientation and spiral-arm handedness, i.e. alignment of disc galaxies, on short distance scales of 1 Mpc h-1. This disc alignment can also cause systematic effects in weak-lensing measurements. Previous observations claimed discovering these correlations but are overly optimistic in the reported level of statistical significance of the detections. Errors in redshift, ellipticity and morphological classifications were not taken into account, although they have a significant impact. We explain how to rigorously propagate all the important errors through the estimation process. Analysing disc galaxies in the Sloan Digital Sky Survey (SDSS) data base, we find that positive autocorrelations of spiral-arm handedness and angular-momentum orientations on distance scales of 1 Mpc h-1 are plausible but not statistically significant. Current data appear not good enough to constrain parameters of theory. This result agrees with a simple hypothesis test in the Local Group, where we also find no evidence for disc alignment. Moreover, we demonstrate that ellipticity estimates based on second moments are strongly biased by galactic bulges even for Scd galaxies, thereby corrupting correlation estimates and overestimating the impact of disc alignment on weak-lensing studies. Finally, we discuss the potential of future sky surveys. We argue that photometric redshifts have too large errors, i.e. PanSTARRS and LSST cannot be used. Conversely, the EUCLID project will not cover the relevant redshift regime. We also discuss the potentials and problems of front-edge classifications of galaxy discs in order to improve the autocorrelation estimates of angular-momentum orientation.
NASA Astrophysics Data System (ADS)
Willson, M.; Kraus, S.; Kluska, J.; Monnier, J. D.; Ireland, M.; Aarnio, A.; Sitko, M. L.; Calvet, N.; Espaillat, C.; Wilner, D. J.
2016-10-01
Context. Transitional discs are a class of circumstellar discs around young stars with extensive clearing of dusty material within their inner regions on 10s of au scales. One of the primary candidates for this kind of clearing is the formation of planet(s) within the disc that then accrete or clear their immediate area as they migrate through the disc. Aims: The goal of this survey was to search for asymmetries in the brightness distribution around a selection of transitional disc targets. We then aimed to determine whether these asymmetries trace dynamically-induced structures in the disc or the gap-opening planets themselves. Methods: Our sample included eight transitional discs. Using the Keck/NIRC2 instrument we utilised the Sparse Aperture Masking (SAM) interferometry technique to search for asymmetries indicative of ongoing planet formation. We searched for close-in companions using both model fitting and interferometric image reconstruction techniques. Using simulated data, we derived diagnostics that helped us to distinguish between point sources and extended asymmetric disc emission. In addition, we investigated the degeneracy between the contrast and separation that appear for marginally resolved companions. Results: We found FP Tau to contain a previously unseen disc wall, and DM Tau, LkHα330, and TW Hya to contain an asymmetric signal indicative of point source-like emission. We placed upper limits on the contrast of a companion in RXJ 1842.9-3532 and V2246 Oph. We ruled the asymmetry signal in RXJ 1615.3-3255 and V2062 Oph to be false positives. In the cases where our data indicated a potential companion we computed estimates for the value of McṀc and found values in the range of . Conclusions: We found significant asymmetries in four targets. Of these, three were consistent with companions. We resolved a previously unseen gap in the disc of FP Tau extending inwards from approximately 10 au. Based on observations made with the Keck observatory (NASA program IDs N104N2 and N121N2).
Localization of optic disc and fovea in retinal images using intensity based line scanning analysis.
Kamble, Ravi; Kokare, Manesh; Deshmukh, Girish; Hussin, Fawnizu Azmadi; Mériaudeau, Fabrice
2017-08-01
Accurate detection of diabetic retinopathy (DR) mainly depends on identification of retinal landmarks such as optic disc and fovea. Present methods suffer from challenges like less accuracy and high computational complexity. To address this issue, this paper presents a novel approach for fast and accurate localization of optic disc (OD) and fovea using one-dimensional scanned intensity profile analysis. The proposed method utilizes both time and frequency domain information effectively for localization of OD. The final OD center is located using signal peak-valley detection in time domain and discontinuity detection in frequency domain analysis. However, with the help of detected OD location, the fovea center is located using signal valley analysis. Experiments were conducted on MESSIDOR dataset, where OD was successfully located in 1197 out of 1200 images (99.75%) and fovea in 1196 out of 1200 images (99.66%) with an average computation time of 0.52s. The large scale evaluation has been carried out extensively on nine publicly available databases. The proposed method is highly efficient in terms of quickly and accurately localizing OD and fovea structure together compared with the other state-of-the-art methods. Copyright © 2017 Elsevier Ltd. All rights reserved.
Singh, Anushikha; Dutta, Malay Kishore; ParthaSarathi, M; Uher, Vaclav; Burget, Radim
2016-02-01
Glaucoma is a disease of the retina which is one of the most common causes of permanent blindness worldwide. This paper presents an automatic image processing based method for glaucoma diagnosis from the digital fundus image. In this paper wavelet feature extraction has been followed by optimized genetic feature selection combined with several learning algorithms and various parameter settings. Unlike the existing research works where the features are considered from the complete fundus or a sub image of the fundus, this work is based on feature extraction from the segmented and blood vessel removed optic disc to improve the accuracy of identification. The experimental results presented in this paper indicate that the wavelet features of the segmented optic disc image are clinically more significant in comparison to features of the whole or sub fundus image in the detection of glaucoma from fundus image. Accuracy of glaucoma identification achieved in this work is 94.7% and a comparison with existing methods of glaucoma detection from fundus image indicates that the proposed approach has improved accuracy of classification. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Chemonucleolysis for relief of sciatica due to a herniated intervertebral disc.
McCulloch, J A
1981-01-01
Chemonucleolysis is the nonoperative chemical removal of displaced lumbar disc material. The enzyme chymopapain, which has a wide margin of safety between its effective therapeutic and toxic doses, is effective in the management of sciatica due to a herniated intervertebral disc. The patient will have leg pain as the dominant symptom and a 50% reduction in straight-leg raising with or without bowstring discomfort and crossover pain. Neurologic symptoms and signs are usual, as are abnormal results of contrast studies, which will verify the level of involvement. In 220 randomly selected patients who met criteria for the diagnosis of sciatica due to a herniated intervertebral disc and did not have psychogenic or nonorganic spinal pain, a spinal stenosis or a history of a previous, unsuccessful operation to relieve the sciatica, chemonucleolysis had a success rate of 80%. The only complications were a severe anaphylactic reaction in two patients and lesser, delayed reactions in five others. All of the reactions were successfully treated. Of the 45 patients in whom chemonucleolysis was unsuccessful, 38 underwent a laminectomy. In 3 of the 38 the results of chemonucleolysis were initially good, but later the disc herniation recurred; thus, the long-term treatment failure rate was 1.4%. PMID:7011530
Efficient radiative transfer techniques in hydrodynamic simulations
NASA Astrophysics Data System (ADS)
Mercer, A.; Stamatellos, D.; Dunhill, A.
2018-05-01
Radiative transfer is an important component of hydrodynamic simulations as it determines the thermal properties of a physical system. It is especially important in cases where heating and cooling regulate significant processes, such as in the collapse of molecular clouds, the development of gravitational instabilities in protostellar discs, disc-planet interactions, and planet migration. We compare two approximate radiative transfer methods which indirectly estimate optical depths within hydrodynamic simulations using two different metrics: (i) the gravitational potential and density of the gas (Stamatellos et al.), and (ii) the pressure scale-height (Lombardi et al.). We find that both methods are accurate for spherical configurations e.g. in collapsing molecular clouds and within clumps that form in protostellar discs. However, the pressure scale-height approach is more accurate in protostellar discs (low and high-mass discs, discs with spiral features, discs with embedded planets). We also investigate the β-cooling approximation which is commonly used when simulating protostellar discs, and in which the cooling time is proportional to the orbital period of the gas. We demonstrate that the use of a constant β cannot capture the wide range of spatial and temporal variations of cooling in protostellar discs, which may affect the development of gravitational instabilities, planet migration, planet mass growth, and the orbital properties of planets.
Signatures of broken protoplanetary discs in scattered light and in sub-millimetre observations
NASA Astrophysics Data System (ADS)
Facchini, Stefano; Juhász, Attila; Lodato, Giuseppe
2018-02-01
Spatially resolved observations of protoplanetary discs are revealing that their inner regions can be warped or broken from the outer disc. A few mechanisms are known to lead to such 3D structures; among them, the interaction with a stellar companion. We perform a 3D SPH simulation of a circumbinary disc misaligned by 60° with respect to the binary orbital plane. The inner disc breaks from the outer regions, precessing as a rigid body and leading to a complex evolution. As the inner disc precesses, the misalignment angle between the inner and outer discs varies by more than 100°. Different snapshots of the evolution are post-processed with a radiative transfer code, in order to produce observational diagnostics of the process. Even though the simulation was produced for the specific case of a circumbinary disc, most of the observational predictions hold for any disc hosting a precessing inner rim. Synthetic scattered light observations show strong azimuthal asymmetries, where the pattern depends strongly on the misalignment angle between the inner and outer discs. The asymmetric illumination of the outer disc leads to azimuthal variations of the temperature structure, in particular in the upper layers, where the cooling time is short. These variations are reflected in asymmetric surface brightness maps of optically thick lines, as CO J = 3-2. The kinematical information obtained from the gas lines is unique in determining the disc structure. The combination of scattered light images and (sub-)mm lines can distinguish between radial inflow and misaligned inner disc scenarios.
26 CFR 1.994-2 - Marginal costing rules.
Code of Federal Regulations, 2011 CFR
2011-04-01
... labor 20.00 (iii) Total deductions 60.00 (c) Maximum combined taxable income 25.00 (4) Overall profit... qualify as export promotion expenses may be so claimed as export promotion expenses. (3) Overall profit... (determined under § 1.993-6) of the DISC derived from such sales, multiplied by the overall profit percentage...
The role of gap edge instabilities in setting the depth of planet gaps in protoplanetary discs
NASA Astrophysics Data System (ADS)
Hallam, P. D.; Paardekooper, S.-J.
2017-08-01
It is known that an embedded massive planet will open a gap in a protoplanetary disc via angular momentum exchange with the disc material. The resulting surface density profile of the disc is investigated for one-dimensional and two-dimensional disc models and, in agreement with previous work, it is found that one-dimensional gaps are significantly deeper than their two-dimensional counterparts for the same initial conditions. We find, by applying one-dimensional torque density distributions to two-dimensional discs containing no planet, that the excitement of the Rossby wave instability and the formation of Rossby vortices play a critical role in setting the equilibrium depth of the gap. Being a two-dimensional instability, this is absent from one-dimensional simulations and does not limit the equilibrium gap depth there. We find similar gap depths between two-dimensional gaps formed by torque density distributions, in which the Rossby wave instability is present, and two-dimensional planet gaps, in which no Rossby wave instability is present. This can be understood if the planet gap is maintained at marginal stability, even when there is no obvious Rossby wave instability present. Further investigation shows the final equilibrium gap depth is very sensitive to the form of the applied torque density distribution, and using improved one-dimensional approximations from three-dimensional simulations can go even further towards reducing the discrepancy between one- and two-dimensional models, especially for lower mass planets. This behaviour is found to be consistent across discs with varying parameters.
1984-01-01
INSTR CONN ARMY OPTICAL INSTRUMENTS 83 CONTRAVES GOERZ CORPORATION PENN ARMY OPTICAL INSTRUMENTS 1.830 CORDIN COMPANY UTAH ARMY OPTICAL INSTRUMENTS 99 D A...CO ALABAMA ARMY OPTICAL INSTRUMENTS 27 INTERACTIVE VIDEO DISC CALIFORNIA NAVY OPTICAL INSTRUMENTS 30 INTERNATIONAL SCTFC INST CALIFORNIA ARMY...PHOTOGRAPHIC SETS KITS AND OUTFITS 41 CALIFORNIA VIDEO SALES INC CALIFORNIA ARMY PHOTOGRAPHIC SETS KITS AND OUTFITS 31 CONTRAVES GOERZ CORPORATION
1991-11-01
Tilted Rough Disc," Donald J. Schertler and Nicholas George "Image Deblurring for Multiple-Point Impulse Responses," Bryan J. Stossel and Nicholas George...Rough Disc Donald J. Schertler Nicholas George Image Deblurring for Multiple-Point Impulse Bryan J. Stossel Responses Nicholas George z 0 zw V) w LU 0...number of impulses present in the degradation. IMAGE DEBLURRING FOR MULTIPLE-POINT IMPULSE RESPONSESt Bryan J. Stossel Nicholas George Institute of Optics
Fast luminous blue transients from newborn black holes
NASA Astrophysics Data System (ADS)
Kashiyama, Kazumi; Quataert, Eliot
2015-08-01
Newborn black holes in collapsing massive stars can be accompanied by a fallback disc. The accretion rate is typically super-Eddington and strong disc outflows are expected. Such outflows could be directly observed in some failed explosions of compact (blue supergiants or Wolf-Rayet stars) progenitors, and may be more common than long-duration gamma-ray bursts. Using an analytical model, we show that the fallback disc outflows produce blue UV-optical transients with a peak bolometric luminosity of ˜ 1042-43 erg s- 1 (peak R-band absolute AB magnitudes of -16 to -18) and an emission duration of ˜ a few to ˜10 d. The spectra are likely dominated intermediate mass elements, but will lack much radioactive nuclei and iron-group elements. The above properties are broadly consistent with some of the rapid blue transients detected by Panoramic Survey Telescope & Rapid Response System and Palomar Transient Factory. This scenario can be distinguished from alternative models using radio observations within a few years after the optical peak.
Panda, Rashmi; Puhan, N B; Panda, Ganapati
2018-02-01
Accurate optic disc (OD) segmentation is an important step in obtaining cup-to-disc ratio-based glaucoma screening using fundus imaging. It is a challenging task because of the subtle OD boundary, blood vessel occlusion and intensity inhomogeneity. In this Letter, the authors propose an improved version of the random walk algorithm for OD segmentation to tackle such challenges. The algorithm incorporates the mean curvature and Gabor texture energy features to define the new composite weight function to compute the edge weights. Unlike the deformable model-based OD segmentation techniques, the proposed algorithm remains unaffected by curve initialisation and local energy minima problem. The effectiveness of the proposed method is verified with DRIVE, DIARETDB1, DRISHTI-GS and MESSIDOR database images using the performance measures such as mean absolute distance, overlapping ratio, dice coefficient, sensitivity, specificity and precision. The obtained OD segmentation results and quantitative performance measures show robustness and superiority of the proposed algorithm in handling the complex challenges in OD segmentation.
NASA Astrophysics Data System (ADS)
Ballabio, G.; Dipierro, G.; Veronesi, B.; Lodato, G.; Hutchison, M.; Laibe, G.; Price, D. J.
2018-06-01
We describe a new implementation of the one-fluid method in the SPH code PHANTOM to simulate the dynamics of dust grains in gas protoplanetary discs. We revise and extend previously developed algorithms by computing the evolution of a new fluid quantity that produces a more accurate and numerically controlled evolution of the dust dynamics. Moreover, by limiting the stopping time of uncoupled grains that violate the assumptions of the terminal velocity approximation, we avoid fatal numerical errors in mass conservation. We test and validate our new algorithm by running 3D SPH simulations of a large range of disc models with tightly and marginally coupled grains.
NASA Astrophysics Data System (ADS)
Bonsor, Amy; Farihi, Jay; Wyatt, Mark C.; van Lieshout, Rik
2017-06-01
Infrared excesses around metal-polluted white dwarfs have been associated with the accretion of dusty planetary material. This work analyses the available infrared data for an unbiased sample of white dwarfs and demonstrates that no more than 3.3 per cent can have a wide, flat, opaque dust disc, extending to the Roche radius, with a temperature at the disc inner edge of Tin = 1400 K, the standard model for the observed excesses. This is in stark contrast to the incidence of pollution of about 30 per cent. We present four potential reasons for the absence of an infrared excess in polluted white dwarfs, depending on their stellar properties and inferred accretion rates: (I) their dust discs are opaque, but narrow, thus evading detection if more than 85 per cent of polluted white dwarfs have dust discs narrower than δr < 0.04r, (II) their dust discs have been fully consumed, which only works for the oldest white dwarfs with sinking time-scales longer than hundreds of years, (III) their dust is optically thin, which can supply low accretion rates of <107 gs-1 if dominated by (Poynting-Robertson) PR-drag, and higher accretion rates, if inwards transport of material is enhanced, e.g. due to the presence of gas, (IV) their accretion is supplied by a pure gas disc, which could result from the sublimation of optically thin dust for T* > 20 000 K. Future observations sensitive to faint infrared excesses or the presence of gas can test the scenarios presented here, thereby better constraining the nature of the material fuelling accretion in polluted white dwarfs.
What made discy galaxies giant?
NASA Astrophysics Data System (ADS)
Saburova, A. S.
2018-01-01
I studied giant discy galaxies with optical radii more than 30 kpc. The comparison of these systems with discy galaxies of moderate sizes revealed that they tend to have higher rotation velocities, B-band luminosities, H I masses and dark-to-luminous mass ratios. The giant discs follow the trend log (M_{H I})(R_{25}) found for normal sized galaxies. It indicates the absence of the peculiarities of evolution of star formation in these galaxies. The H I mass-to-luminosity ratio of giant galaxies appears not to differ from that of normal-sized galaxies, giving evidence in favour of similar star formation efficiency. I also found that the bars and rings occur more frequently among giant discs. I performed mass modelling of the subsample of 18 giant galaxies with available rotation curves and surface photometry data and constructed χ2 maps for the parameters of their dark matter haloes. These estimates indicate that giant discs tend to be formed in larger more massive and rarified dark haloes in comparison to moderate-sized galaxies. However, giant galaxies do not deviate significantly from the relations between the optical sizes and dark halo parameters for moderate-sized galaxies. These findings can rule out the catastrophic scenario of the formation of at least most of giant discs, since they follow the same relations as normal discy galaxies. The giant sizes of the discs can be due to the high radial scale of the dark matter haloes in which they were formed.
NASA Astrophysics Data System (ADS)
Barman, Anjan; Barman, Saswati; Kimura, T.; Fukuma, Y.; Otani, Y.
2010-10-01
We present the experimental observation of gyration mode splitting by the time-resolved magneto-optical Kerr effect in an array consisting of magnetostatically coupled Ni81Fe19 discs of 1 µm diameter, 50 nm thickness and inter-disc separations varying between 150 and 270 nm. A splitting of the vortex core gyration mode is observed when the inter-disc separation is 200 nm or less and the splitting is controllable by a bias magnetic field. The observed mode splitting is interpreted by micromagnetic simulations as the normal modes of the vortex cores analogous to the coupled classical oscillators. The splitting depends upon the strength of the inter-disc magnetostatic coupling mediated by magnetic side charges, which depends strongly on the magnetic ground states of the samples.
Observability of forming planets and their circumplanetary discs - I. Parameter study for ALMA
NASA Astrophysics Data System (ADS)
Szulágyi, J.; Plas, G. van der; Meyer, M. R.; Pohl, A.; Quanz, S. P.; Mayer, L.; Daemgen, S.; Tamburello, V.
2018-01-01
We present mock observations of forming planets with Atacama Large Millimeter Array (ALMA). The possible detections of circumplanetary discs (CPDs) were investigated around planets of Saturn, 1, 3, 5, and 10 Jupiter-masses that are placed at 5.2 au from their star. The radiative, 3D hydrodynamic simulations were then post-processed with RADMC3D and the ALMA observation simulator. We found that even though the CPDs are too small to be resolved, they are hot due to the accreting planet in the optically thick limit; therefore, the best chance to detect them with continuum observations in this case is at the shortest ALMA wavelengths, such as band 9 (440 μm). Similar fluxes were found in the case of Saturn and Jupiter-mass planets, as for the 10 MJup gas-giant, due to temperature-weighted optical depth effects: when no deep gap is carved, the planet region is blanketed by the optically thick circumstellar disc leading to a less efficient cooling there. A test was made for a 52 au orbital separation, which showed that optically thin CPDs are also detectable in band 7 but they need longer integration times (>5 h). Comparing the gap profiles of the same simulation at various ALMA bands and the hydro simulation confirmed that they change significantly, first because the gap is wider at longer wavelengths due to decreasing optical depth; secondly, the beam convolution makes the gap shallower and at least 25 per cent narrower. Therefore, caution has to be made when estimating planet masses based on ALMA continuum observations of gaps.
NASA Astrophysics Data System (ADS)
Zakhozhay, Olga V.; Zapatero Osorio, María Rosa; Béjar, Víctor J. S.; Boehler, Yann
2017-01-01
The origin of the very red optical and infrared colours of intermediate-age (˜10-500 Myr) L-type dwarfs remains unknown. It has been suggested that low-gravity atmospheres containing large amounts of dust may account for the observed reddish nature. We explored an alternative scenario by simulating debris disc around G 196-3 B, which is an L3 young brown dwarf with a mass of ˜15 MJup and an age in the interval 20-300 Myr. The best-fit solution to G 196-3 B's photometric spectral energy distribution from optical wavelengths through 24 μm corresponds to the combination of an unreddened L3 atmosphere (Teff ≈ 1870 K) and a warm (≈1280 K), narrow (≈0.07-0.11 R⊙) debris disc located at very close distances (≈0.12-0.20 R⊙) from the central brown dwarf. This putative, optically thick, dusty belt, whose presence is compatible with the relatively young system age, would have a mass ≥7 × 10-10 M⊕ comprised of submicron/micron characteristic dusty particles with temperatures close to the sublimation threshold of silicates. Considering the derived global properties of the belt and the disc-to-brown dwarf mass ratio, the dusty ring around G 196-3 B may resemble the rings of Neptune and Jupiter, except for its high temperature and thick vertical height (≈6 × 103 km). Our inferred debris disc model is able to reproduce G 196-3 B's spectral energy distribution to a satisfactory level of achievement.
NASA Astrophysics Data System (ADS)
Kaufman, J.; Blaes, O. M.; Hirose, S.
2018-06-01
Warm Comptonization models for the soft X-ray excess in active galactic nuclei (AGN) do not self-consistently explain the relationship between the Comptonizing medium and the underlying accretion disc. Because of this, they cannot directly connect the fitted Comptonization temperatures and optical depths to accretion disc parameters. Since bulk velocities exceed thermal velocities in highly radiation pressure dominated discs, in these systems bulk Comptonization by turbulence may provide a physical basis in the disc itself for warm Comptonization models. We model the dependence of bulk Comptonization on fundamental accretion disc parameters, such as mass, luminosity, radius, spin, inner boundary condition, and α. In addition to constraining warm Comptonization models, our model can help distinguish contributions from bulk Comptonization to the soft X-ray excess from those due to other physical mechanisms, such as absorption and reflection. By linking the time variability of bulk Comptonization to fluctuations in the disc vertical structure due to magnetorotational instability (MRI) turbulence, our results show that observations of the soft X-ray excess can be used to study disc turbulence in the radiation pressure dominated regime. Because our model connects bulk Comptonization to 1D vertical structure temperature profiles in a physically intuitive way, it will be useful for understanding this effect in future simulations run in new regimes.
Galactic star formation enhanced and quenched by ram pressure in groups and clusters
NASA Astrophysics Data System (ADS)
Bekki, Kenji
2014-02-01
We investigate how ram pressure of intragroup and intracluster medium can influence the spatial and temporal variations of star formation (SF) of disc galaxies with halo masses (Mh) ranging from 1010 to 1012 M⊙ (i.e. from dwarf irregular to Milky Way-type) in groups and clusters with 1013 ≤ Mh/M⊙ ≤ 1015 by using numerical simulations with a new model for time-varying ram pressure. The long-term evolution of SF rates and Hα morphologies corresponding to the distributions of star-forming regions are particularly investigated for different model parameters. The principal results are as follows. Whether ram pressure can enhance or reduce SF depends on Mh of disc galaxies and inclination angles of gas discs with respect to their orbital directions for a given orbit and a given environment. For example, SF can be moderately enhanced in disc galaxies with Mh = 1012 M⊙ at the pericentre passages in a cluster with Mh = 1014 M⊙ whereas it can be completely shut down (`quenching') for low-mass discs with Mh = 1010 M⊙. Ram pressure can reduce the Hα-to-optical-disc-size ratios of discs and the level of the reduction depends on Mh and orbits of disc galaxies for a given environment. Disc galaxies under strong ram pressure show characteristic Hα morphologies such as ring-like, one-sided and crescent-like distributions.
3D optic disc reconstruction via a global fundus stereo algorithm.
Bansal, M; Sizintsev, M; Eledath, J; Sawhney, H; Pearson, D J; Stone, R A
2013-01-01
This paper presents a novel method to recover 3D structure of the optic disc in the retina from two uncalibrated fundus images. Retinal images are commonly uncalibrated when acquired clinically, creating rectification challenges as well as significant radiometric and blur differences within the stereo pair. By exploiting structural peculiarities of the retina, we modified the Graph Cuts computational stereo method (one of current state-of-the-art methods) to yield a high quality algorithm for fundus stereo reconstruction. Extensive qualitative and quantitative experimental evaluation (where OCT scans are used as 3D ground truth) on our and publicly available datasets shows the superiority of the proposed method in comparison to other alternatives.
Automated Detection of Optic Disc in Fundus Images
NASA Astrophysics Data System (ADS)
Burman, R.; Almazroa, A.; Raahemifar, K.; Lakshminarayanan, V.
Optic disc (OD) localization is an important preprocessing step in the automated image detection of fundus image infected with glaucoma. An Interval Type-II fuzzy entropy based thresholding scheme along with Differential Evolution (DE) is applied to determine the location of the OD in the right of left eye retinal fundus image. The algorithm, when applied to 460 fundus images from the MESSIDOR dataset, shows a success rate of 99.07 % for 217 normal images and 95.47 % for 243 pathological images. The mean computational time is 1.709 s for normal images and 1.753 s for pathological images. These results are important for automated detection of glaucoma and for telemedicine purposes.
NASA Astrophysics Data System (ADS)
Panwar, Neelam; Samal, M. R.; Pandey, A. K.; Jose, J.; Chen, W. P.; Ojha, D. K.; Ogura, K.; Singh, H. P.; Yadav, R. K.
2017-07-01
W4 is a giant H II region ionized by the OB stars of the cluster IC 1805. The H II region/cluster complex has been a subject of numerous investigations as it is an excellent laboratory for studying the feedback effect of massive stars on the surrounding region. However, the low-mass stellar content of the cluster IC 1805 remains poorly studied till now. With the aim to unravel the low-mass stellar population of the cluster, we present the results of a multiwavelength study based on deep optical data obtained with the Canada-France-Hawaii Telescope, infrared data from Two Micron All Sky Survey and Spitzer Space Telescope and X-ray data from Chandra Space Telescope. The present optical data set is complete enough to detect stars down to 0.2 M⊙, which is the deepest optical observation so far for the cluster. We identified 384 candidate young stellar objects (YSOs; 101 Class I/II and 283 Class III) within the cluster using various colour-colour and colour-magnitude diagrams. We inferred the mean age of the identified YSOs to be ˜2.5 Myr and mass in the range 0.3-2.5 M⊙. The mass function of our YSO sample has a power-law index of -1.23 ± 0.23, close to the Salpeter value (-1.35), and consistent with those of other star-forming complexes. We explored the disc evolution of the cluster members and found that the disc-less sources are relatively older compared to the disc bearing YSO candidates. We examined the effect of high-mass stars on the circumstellar discs and within uncertainties, the influence of massive stars on the disc fraction seems to be insignificant. We also studied the spatial correlation of the YSOs with the distribution of gas and dust of the complex to conclude that IC 1805 would have formed in a large filamentary cloud.
Reading disc-based bioassays with standard computer drives.
Yu, Hua-Zhong; Li, Yunchao; Ou, Lily M-L
2013-02-19
Traditional methods of disease diagnosis are both time-consuming and labor-intensive, and many tests require expensive instrumentation and trained professionals, which restricts their use to biomedical laboratories. Because patients can wait several days (even weeks) for the results, the consequences of delayed treatment could be disastrous. Therefore, affordable and simple point-of-care (POC) biosensor devices could fill a diagnostic niche in the clinic or even at home, as personal glucose meters do for diabetics. These devices would allow patients to check their own health conditions and enable physicians to make prompt treatment decisions, which could improve the chances for rapid recovery and cure. Compact discs (CDs) provide inexpensive substrate materials for the preparation of microarray biochips, and conventional computer drives/disc players can be adapted as precise optical reading devices for signal processing. Researchers can employ the polycarbonate (PC) base of a CD as an alternative substrate to glass slides or silicon wafers for the preparation of microanalytical devices. Using the characteristic optical phenomena occurring on the metal layer of a CD, researchers can develop biosensors based on advanced spectroscopic readout (interferometry or surface plasmon resonance). If researchers integrate microfluidic functions with CD mechanics, they can control fluid transfer through the spinning motion of the disc, leading to "lab-on-a-CD" devices. Over the last decade, our laboratory has focused on the construction of POC biosensor devices from off-the-shelf CDs or DVDs and standard computer drives. Besides the initial studies of the suitability of CDs for surface and materials chemistry research (fabrication of self-assembled monolayers and oxide nanostructures), we have demonstrated that an ordinary optical drive, without modification of either the hardware or the software driver, can function as the signal transducing element for reading disc-based bioassays quantitatively. In this Account, we first provide a brief introduction to CD-related materials chemistry and microfluidics research. Then we describe the mild chemistry developed in our laboratory for the preparation of computer-readable biomolecular screening assays: photochemical activation of the polycarbonate (PC) disc surface and immobilization and delivery of probe and target biomolecules. We thoroughly discuss the analysis of the molecular recognition events: researchers can "read" these devices quantitatively with an unmodified optical drive of any personal computer. Finally, and critically, we illustrate our digitized molecular diagnosis approach with three trial systems: DNA hybridization, antibody-antigen binding, and ultrasensitive lead detection with a DNAzyme assay. These examples demonstrate the broad potential of this new analytical/diagnostic tool for medical screening, on-site food/water safety testing, and remote environmental monitoring.
NASA Astrophysics Data System (ADS)
Dexter, Jason; McKinney, Jonathan C.; Markoff, Sera; Tchekhovskoy, Alexander
2014-05-01
Magnetically arrested accretion discs (MADs), where the magnetic pressure in the inner disc is dynamically important, provide an alternative mechanism for regulating accretion to what is commonly assumed in black hole systems. We show that a global magnetic field inversion in the MAD state can destroy the jet, significantly increase the accretion rate, and move the effective inner disc edge in to the marginally stable orbit. Reconnection of the MAD field in the inner radii launches a new type of transient outflow containing hot plasma generated by magnetic dissipation. This transient outflow can be as powerful as the steady magnetically dominated Blandford-Znajek jet in the MAD state. The field inversion qualitatively describes many of the observational features associated with the high-luminosity hard-to-soft state transition in black hole X-ray binaries: the jet line, the transient ballistic jet, and the drop in rms variability. These results demonstrate that the magnetic field configuration can influence the accretion state directly, and hence the magnetic field structure is an important second parameter in explaining observations of accreting black holes across the mass and luminosity scales.
Modelling hard and soft states of Cygnus X-1 with propagating mass accretion rate fluctuations
NASA Astrophysics Data System (ADS)
Rapisarda, S.; Ingram, A.; van der Klis, M.
2017-12-01
We present a timing analysis of three Rossi X-ray Timing Explorer observations of the black hole binary Cygnus X-1 with the propagating mass accretion rate fluctuations model PROPFLUC. The model simultaneously predicts power spectra, time lags and coherence of the variability as a function of energy. The observations cover the soft and hard states of the source, and the transition between the two. We find good agreement between model predictions and data in the hard and soft states. Our analysis suggests that in the soft state the fluctuations propagate in an optically thin hot flow extending up to large radii above and below a stable optically thick disc. In the hard state, our results are consistent with a truncated disc geometry, where the hot flow extends radially inside the inner radius of the disc. In the transition from soft to hard state, the characteristics of the rapid variability are too complex to be successfully described with PROPFLUC. The surface density profile of the hot flow predicted by our model and the lack of quasi-periodic oscillations in the soft and hard states suggest that the spin of the black hole is aligned with the inner accretion disc and therefore probably with the rotational axis of the binary system.
Laser-induced activation of regeneration processes in spine disc cartilage
NASA Astrophysics Data System (ADS)
Sobol, Emil N.; Vorobjeva, Natalia N.; Sviridov, Alexander P.; Omelchenko, Alexander I.; Baskov, Andrey V.; Shekhter, Anatoliy B.; Baskov, Vladimir A.; Feldchtein, Felix I.; Kamensky, Vladislav A.; Kuranov, Roman V.
2000-05-01
The effect of laser radiation on the regeneration processes in spine disk cartilage has been studied in-vivo. We used rabbits as a model and a Holmium (2.09 micrometer) and an Erbium fiber (1.56 micrometer) lasers for irradiation the discs which were preliminary opened to remove annulus fibrosus and the nucleus pulposus of the intervertebral disc. The irradiated zone has been examined using an optical coherent tomography in one month after the operation and conventional histological technique in two months after the laser operation. It has been shown that laser radiation promotes the growth of the new cartilaginous tissue of fibrous and hyaline types.
The near-infrared broad emission line region of active galactic nuclei - II. The 1-μm continuum
NASA Astrophysics Data System (ADS)
Landt, Hermine; Elvis, Martin; Ward, Martin J.; Bentz, Misty C.; Korista, Kirk T.; Karovska, Margarita
2011-06-01
We use quasi-simultaneous near-infrared (near-IR) and optical spectroscopy from four observing runs to study the continuum around 1 μm in 23 well-known broad emission line active galactic nuclei (AGN). We show that, after correcting the optical spectra for host galaxy light, the AGN continuum around this wavelength can be approximated by the sum of mainly two emission components, a hot dust blackbody and an accretion disc. The accretion disc spectrum appears to dominate the flux at ˜ 1 μm, which allows us to derive a relation for estimating AGN black hole masses based on the near-IR virial product. This result also means that a near-IR reverberation programme can determine the AGN state independent of simultaneous optical spectroscopy. On average we derive hot dust blackbody temperatures of ˜1400 K, a value close to the sublimation temperature of silicate dust grains, and relatively low hot dust covering factors of ˜7 per cent. Our preliminary variability studies indicate that in most sources, the hot dust emission responds to changes in the accretion disc flux with the expected time lag; however, a few sources show a behaviour that can be attributed to dust destruction.
NASA Astrophysics Data System (ADS)
Baglio, M. C.; Campana, S.; D'Avanzo, P.; Papitto, A.; Burderi, L.; Di Salvo, T.; Muñoz-Darias, T.; Rea, N.; Torres, D. F.
2017-04-01
We present an optical (gri) study during quiescence of the accreting millisecond X-ray pulsar IGR J00291+5934 performed with the 10.4 m Gran Telescopio Canarias (GTC) in August 2014. Although the source was in quiescence at the time of our observations, it showed a strong optical flaring activity, more pronounced in bluer filters (I.e. the g-band). After subtracting the flares, we tentatively recovered a sinusoidal modulation at the system orbital period in all bands, even when a significant phase shift with respect to an irradiated star, typical of accreting millisecond X-ray pulsars, was detected. We conclude that the observed flaring could be a manifestation of the presence of an accretion disc in the system. The observed light curve variability could be explained by the presence of a superhump, which might be another proof of the formation of an accretion disc. In particular, the disc at the time of our observations was probably preparing the new outburst of the source, which occurred a few months later, in 2015. Based on observations made with the Gran Telescopio Canarias (GTC), installed in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofísica de Canarias, in the island of La Palma.
Application of phase-change materials in memory taxonomy.
Wang, Lei; Tu, Liang; Wen, Jing
2017-01-01
Phase-change materials are suitable for data storage because they exhibit reversible transitions between crystalline and amorphous states that have distinguishable electrical and optical properties. Consequently, these materials find applications in diverse memory devices ranging from conventional optical discs to emerging nanophotonic devices. Current research efforts are mostly devoted to phase-change random access memory, whereas the applications of phase-change materials in other types of memory devices are rarely reported. Here we review the physical principles of phase-change materials and devices aiming to help researchers understand the concept of phase-change memory. We classify phase-change memory devices into phase-change optical disc, phase-change scanning probe memory, phase-change random access memory, and phase-change nanophotonic device, according to their locations in memory hierarchy. For each device type we discuss the physical principles in conjunction with merits and weakness for data storage applications. We also outline state-of-the-art technologies and future prospects.
Optically thin core accretion: how planets get their gas in nearly gas-free discs
NASA Astrophysics Data System (ADS)
Lee, Eve J.; Chiang, Eugene; Ferguson, Jason W.
2018-05-01
Models of core accretion assume that in the radiative zones of accreting gas envelopes, radiation diffuses. But super-Earths/sub-Neptunes (1-4 R⊕, 2-20 M⊕) point to formation conditions that are optically thin: their modest gas masses are accreted from short-lived and gas-poor nebulae reminiscent of the transparent cavities of transitional discs. Planetary atmospheres born in such environments can be optically thin to both incident starlight and internally generated thermal radiation. We construct time-dependent models of such atmospheres, showing that super-Earths/sub-Neptunes can accrete their ˜1 per cent-by-mass gas envelopes, and super-puffs/sub-Saturns their ˜20 per cent-by-mass envelopes, over a wide range of nebular depletion histories requiring no fine tuning. Although nascent atmospheres can exhibit stratospheric temperature inversions affected by atomic Fe and various oxides that absorb strongly at visible wavelengths, the rate of gas accretion remains controlled by the radiative-convective boundary (rcb) at much greater pressures. For dusty envelopes, the temperature at the rcb Trcb ≃ 2500 K is still set by H2 dissociation; for dust-depleted envelopes, Trcb tracks the temperature of the visible or thermal photosphere, whichever is deeper, out to at least ˜5 au. The rate of envelope growth remains largely unchanged between the old radiative diffusion models and the new optically thin models, reinforcing how robustly super-Earths form as part of the endgame chapter in disc evolution.
Galaxy Evolution in the Reddest Possible Filter
NASA Astrophysics Data System (ADS)
Richards, E. A.
We describe an observational programme aimed at understanding the radio emission from distant, rapidly evolving galaxy populations. These observations were carried out at 1.4 and 8.5 GHz with the VLA, centred on the Hubble Deep Field, obtaining limiting flux densities of 40 and 8 μJy respectively. The differential count of the radio sources is marginally sub-Euclidean to the completeness limits (γ = - 2.4 +/- 0.1) and fluctuation analysis suggests nearly 60 sources per arcmin^2 at the 1 μJy level. Using high-resolution 1.4 GHz observations obtained with MERLIN, we resolve all radio sources detected in the VLA complete sample and measure a median angular size for the microjansky radio population of 1-2``. This clue, coupled with the steep spectral index of the 1.4 GHz selected sample, suggests diffuse synchrotron radiation in z ~ 1 galactic discs. The wide-field HST and ground-based optical exposures show that the radio sources are identified primarily with disc systems composed of irregulars, peculiars, interacting/merging galaxies and a few isolated field spirals. Only 20% of the radio sources can be attributed to AGN - the majority are probably associated with starburst activity. The available redshifts range from 0.1 to 3, with a mean of about 0.8. We are plrobably witnessing a major episode of starburst activity in these luminous (L > L_*) systems, occasionally accompanied by an embedded AGN. About 20% of the radio sources remain unidentified to I = 26-28 in the HDF and flanking fields. Several of these objects have extremely red counterparts. We suggest that these are high-redshift dusty protogalaxies.
Technique for positioning hologram for balancing large data capacity with fast readout
NASA Astrophysics Data System (ADS)
Shimada, Ken-ichi; Hosaka, Makoto; Yamazaki, Kazuyoshi; Onoe, Shinsuke; Ide, Tatsuro
2017-09-01
The technical difficulty of balancing large data capacity with a high data transfer rate in holographic data storage systems (HDSSs) is significantly high because of tight tolerances for physical perturbation. From a system margin perspective in terabyte-class HDSSs, the positioning error of a holographic disc should be within about 10 µm to ensure high readout quality. Furthermore, fine control of the positioning should be accomplished within a time frame of about 10 ms for a high data transfer rate of the Gbps class, while a conventional method based on servo control of spindle or sled motors can rarely satisfy the requirement. In this study, a new compensation method for the effect of positioning error, which precisely controls the positioning of a Nyquist aperture instead of a holographic disc, has been developed. The method relaxes the markedly low positional tolerance of a holographic disc. Moreover, owing to the markedly light weight of the aperture, positioning control within the required time frame becomes feasible.
Wang, Jui-Kai; Kardon, Randy H.; Kupersmith, Mark J.; Garvin, Mona K.
2012-01-01
Purpose. To develop an automated method for the quantification of volumetric optic disc swelling in papilledema subjects using spectral-domain optical coherence tomography (SD-OCT) and to determine the extent that such volumetric measurements correlate with Frisén scale grades (from fundus photographs) and two-dimensional (2-D) peripapillary retinal nerve fiber layer (RNFL) and total retinal (TR) thickness measurements from SD-OCT. Methods. A custom image-analysis algorithm was developed to obtain peripapillary circular RNFL thickness, TR thickness, and TR volume measurements from SD-OCT volumes of subjects with papilledema. In addition, peripapillary RNFL thickness measures from the commercially available Zeiss SD-OCT machine were obtained. Expert Frisén scale grades were independently obtained from corresponding fundus photographs. Results. In 71 SD-OCT scans, the mean (± standard deviation) resulting TR volumes for Frisén scale 0 to scale 4 were 11.36 ± 0.56, 12.53 ± 1.21, 14.42 ± 2.11, 17.48 ± 2.63, and 21.81 ± 3.16 mm3, respectively. The Spearman's rank correlation coefficient was 0.737. Using 55 eyes with valid Zeiss RNFL measurements, Pearson's correlation coefficient (r) between the TR volume and the custom algorithm's TR thickness, the custom algorithm's RNFL thickness, and Zeiss' RNFL thickness was 0.980, 0.929, and 0.946, respectively. Between Zeiss' RNFL and the custom algorithm's RNFL, and the study's TR thickness, r was 0.901 and 0.961, respectively. Conclusions. Volumetric measurements of the degree of disc swelling in subjects with papilledema can be obtained from SD-OCT volumes, with the mean volume appearing to be roughly linearly related to the Frisén scale grade. Using such an approach can provide a more continuous, objective, and robust means for assessing the degree of disc swelling compared with presently available approaches. PMID:22599584
The Rate of Visual Field Change in the Ocular Hypertension Treatment Study
De Moraes, Carlos Gustavo V.; Gardiner, Stuart K.; Liebmann, Jeffrey M.; Cioffi, George A.; Ritch, Robert; Gordon, Mae O.; Kass, Michael A.
2012-01-01
Purpose. To assess the rate of change of visual field (VF) mean deviation (MD) in the Ocular Hypertension Treatment Study (OHTS). Methods. OHTS data were filtered to exclude eyes that had fewer than 10 reliable VFs or less than 5 years of follow-up or that reached a nonglaucomatous endpoint. The rate of change of MD (MDR) was calculated for each eye. Differences were sought between groups of eyes differing in primary open angle glaucoma (POAG) outcome, how POAG was determined, and original randomization. Results. In total, 2609 eyes (1379 participants) met the selection criteria. The mean MDR was −0.08 ± 0.20 dB/y (±SD). POAG eyes (n = 359) had significantly worse MDRs (−0.26 ± 0.36 dB/y) than non-POAG eyes (n = 2250; −0.05 ± 0.14 dB/y; P < 0.001). Eyes that reached POAG endpoints based on only VF change (n = 74; −0.29 ± 0.31 dB/y) or only optic disc change (n = 158; −0.12 ± 0.19 dB/y) had significantly worse MDRs than non-POAG eyes (both P < 0.001). Eyes that reached POAG endpoints for both VF and optic disc change (n = 127) deteriorated more rapidly (−0.42 ± 0.46 dB/y) than eyes showing only VF change (P = 0.017) or only optic disc change (P < 0.001). There was not a significant association between MDR and original OHTS randomization (observe vs. treat, P = 0.168). Conclusions. Eyes that develop POAG have significantly worse MDRs than eyes that do not. Eyes that reached endpoints due to both VF and optic disc change had worse MDRs than eyes displaying change in only one of these. MDR was not significantly associated with randomization, suggesting that MDR may not be the best measure of VF change in early-stage POAG. (ClinicalTrials.gov number, NCT00000125.) PMID:22159015
Doppler optical coherence tomography of retinal circulation.
Tan, Ou; Wang, Yimin; Konduru, Ranjith K; Zhang, Xinbo; Sadda, SriniVas R; Huang, David
2012-09-18
Noncontact retinal blood flow measurements are performed with a Fourier domain optical coherence tomography (OCT) system using a circumpapillary double circular scan (CDCS) that scans around the optic nerve head at 3.40 mm and 3.75 mm diameters. The double concentric circles are performed 6 times consecutively over 2 sec. The CDCS scan is saved with Doppler shift information from which flow can be calculated. The standard clinical protocol calls for 3 CDCS scans made with the OCT beam passing through the superonasal edge of the pupil and 3 CDCS scan through the inferonal pupil. This double-angle protocol ensures that acceptable Doppler angle is obtained on each retinal branch vessel in at least 1 scan. The CDCS scan data, a 3-dimensional volumetric OCT scan of the optic disc scan, and a color photograph of the optic disc are used together to obtain retinal blood flow measurement on an eye. We have developed a blood flow measurement software called "Doppler optical coherence tomography of retinal circulation" (DOCTORC). This semi-automated software is used to measure total retinal blood flow, vessel cross section area, and average blood velocity. The flow of each vessel is calculated from the Doppler shift in the vessel cross-sectional area and the Doppler angle between the vessel and the OCT beam. Total retinal blood flow measurement is summed from the veins around the optic disc. The results obtained at our Doppler OCT reading center showed good reproducibility between graders and methods (<10%). Total retinal blood flow could be useful in the management of glaucoma, other retinal diseases, and retinal diseases. In glaucoma patients, OCT retinal blood flow measurement was highly correlated with visual field loss (R(2)>0.57 with visual field pattern deviation). Doppler OCT is a new method to perform rapid, noncontact, and repeatable measurement of total retinal blood flow using widely available Fourier-domain OCT instrumentation. This new technology may improve the practicality of making these measurements in clinical studies and routine clinical practice.
Akar, Munire Erman; Yucel, Iclal; Erdem, Uzeyir; Taskin, Omur; Ozel, Alper; Akar, Yusuf
2005-04-01
The purpose of this study was to examine and compare menstrual-cycle-dependent topographic changes in the optic nerve head of normally menstruating women with different grades of type 2 diabetes mellitus. We studied the right eyes of 123 normally menstruating women (36 with severe nonproliferative diabetic retinopathy [NPDR], 42 with mild NPDR and 45 healthy subjects). All subjects underwent a complete ocular examination at baseline. At 4 hormonally distinct phases of the menstrual cycle (early follicular, late follicular, mid-luteal and late luteal), we analysed the topography of the optic nerve head, using a confocal scanning laser ophthalmoscope, and measured the serum levels of estradiol, progesterone and luteinizing hormone. We excluded from analysis the data for 8 patients with severe NPDR, 10 patients with mild NPDR and 15 control subjects who were lost to follow-up examinations during the menstrual cycle. The mean age and optic disc area did not differ significantly among the 3 groups. The duration of diabetes was significantly longer in the patients with severe NPDR than in those with mild NPDR (p < 0.05). The women with severe NPDR had a significantly increased neuroretinal rim area and a significantly decreased cup-shape measure, linear cup/disc ratio, cup/disc area ratio and cup area in the late luteal phase compared with the other phases of the menstrual cycle (p < 0.05). Those with mild NPDR or a normal retina had no significant topographic changes in the optic nerve head during the menstrual cycle. Severe NPDR is associated with significant topographic changes in the rim and cup of the optic nerve head during the menstrual cycle. This must be considered in the evaluation of women with both diabetes and glaucoma. The normal fluctuations in serum sex hormone levels during the menstrual cycle of diabetic women seem to affect the optic nerve head more when the disease is advanced.
Clinical Validation of a Smartphone-Based Adapter for Optic Disc Imaging in Kenya.
Bastawrous, Andrew; Giardini, Mario Ettore; Bolster, Nigel M; Peto, Tunde; Shah, Nisha; Livingstone, Iain A T; Weiss, Helen A; Hu, Sen; Rono, Hillary; Kuper, Hannah; Burton, Matthew
2016-02-01
Visualization and interpretation of the optic nerve and retina are essential parts of most physical examinations. To design and validate a smartphone-based retinal adapter enabling image capture and remote grading of the retina. This validation study compared the grading of optic nerves from smartphone images with those of a digital retinal camera. Both image sets were independently graded at Moorfields Eye Hospital Reading Centre. Nested within the 6-year follow-up (January 7, 2013, to March 12, 2014) of the Nakuru Eye Disease Cohort in Kenya, 1460 adults (2920 eyes) 55 years and older were recruited consecutively from the study. A subset of 100 optic disc images from both methods were further used to validate a grading app for the optic nerves. Data analysis was performed April 7 to April 12, 2015. Vertical cup-disc ratio for each test was compared in terms of agreement (Bland-Altman and weighted κ) and test-retest variability. A total of 2152 optic nerve images were available from both methods (also 371 from the reference camera but not the smartphone, 170 from the smartphone but not the reference camera, and 227 from neither the reference camera nor the smartphone). Bland-Altman analysis revealed a mean difference of 0.02 (95% CI, -0.21 to 0.17) and a weighted κ coefficient of 0.69 (excellent agreement). The grades of an experienced retinal photographer were compared with those of a lay photographer (no health care experience before the study), and no observable difference in image acquisition quality was found. Nonclinical photographers using the low-cost smartphone adapter were able to acquire optic nerve images at a standard that enabled independent remote grading of the images comparable to those acquired using a desktop retinal camera operated by an ophthalmic assistant. The potential for task shifting and the detection of avoidable causes of blindness in the most at-risk communities makes this an attractive public health intervention.
Enormous disc of cool gas surrounding the nearby powerful radio galaxy NGC612 (PKS0131-36)
NASA Astrophysics Data System (ADS)
Emonts, B. H. C.; Morganti, R.; Oosterloo, T. A.; Holt, J.; Tadhunter, C. N.; van der Hulst, J. M.; Ojha, R.; Sadler, E. M.
2008-06-01
We present the detection of an enormous disc of cool neutral hydrogen (HI) gas surrounding the S0 galaxy NGC612, which hosts one of the nearest powerful radio sources (PKS0131-36). Using the Australia Telescope Compact Array, we detect MHI = 1.8 × 109Msolar of HI emission-line gas that is distributed in a 140-kpc wide disc-like structure along the optical disc and dust lane of NGC612. The bulk of the gas in the disc appears to be settled in regular rotation with a total velocity range of 850kms-1, although asymmetries in this disc indicate that perturbations are being exerted on part of the gas, possibly by a number of nearby companions. The HI disc in NGC612 suggests that the total mass enclosed by the system is Menc ~ 2.9 × 1012 sin-2 iMsolar, implying that this early-type galaxy contains a massive dark matter halo. We also discuss an earlier study by Holt et al. that revealed the presence of a prominent young stellar population at various locations throughout the disc of NGC612, indicating that this is a rare example of an extended radio source that is hosted by a galaxy with a large-scale star-forming disc. In addition, we map a faint HI bridge along a distance of 400kpc in between NGC612 and the gas-rich (MHI = 8.9 × 109Msolar) barred galaxy NGC619, indicating that likely an interaction between both systems occurred. From the unusual amounts of HI gas and young stars in this early-type galaxy, in combination with the detection of a faint optical shell and the system's high infrared luminosity, we argue that either ongoing or past galaxy interactions or a major merger event are a likely mechanism for the triggering of the radio source in NGC612. This paper is part of an ongoing study to map the large-scale neutral hydrogen properties of nearby radio galaxies and it presents the first example of large-scale HI detected around a powerful Fanaroff-Riley type II (FR-II) radio galaxy. The HI properties of the FR-II radio galaxy NGC612 are very similar to those found for low-power compact radio sources, but different from those of extended Fanaroff-Riley type I (FR-I) sources.
Sub-second optical flaring in GX 339-4 during the 2017 outburst early rise
NASA Astrophysics Data System (ADS)
Gandhi, P.; Kotze, M. M.; Buckley, D. A. H.; Paice, J. A.; Altamirano, D.; Charles, P. A.; Russell, D. M.; Fabian, A. C.
2017-10-01
The black hole X-ray binary GX 339-4 has been caught at the early stage of a new outburst. According to optical monitoring, the outburst began between 2017-08-24 and 2017-09-14, presumably in the outer disc (ATel #10797).
Optical Disc Technology and the Cooperative Television Library.
ERIC Educational Resources Information Center
Kranch, Douglas
1989-01-01
Discusses the feasibility of individual television film libraries combining film holdings onto optical disks and developing networks that would allow online searching of, access to, and transmission of video images. It is concluded that recent advances in technology would support fast and cost effective image retrieval with no loss in video…
NASA Astrophysics Data System (ADS)
Hales, Antonio S.; Barlow, M. J.; Crawford, I. A.; Casassus, S.
2017-04-01
We have conducted a search for optical circumstellar absorption lines in the spectra of 16 debris disc host stars. None of the stars in our sample showed signs of emission line activity in either Hα, Ca II or Na I, confirming their more evolved nature. Four stars were found to exhibit narrow absorption features near the cores of the photospheric Ca II and Na I D lines (when Na I D data were available). We analyse the characteristics of these spectral features to determine whether they are of circumstellar or interstellar origins. The strongest evidence for circumstellar gas is seen in the spectrum of HD 110058, which is known to host a debris disc observed close to edge-on. This is consistent with a recent ALMA detection of molecular gas in this debris disc, which shows many similarities to the β Pictoris system.
The variability of accretion on to Schwarzschild black holes from turbulent magnetized discs
NASA Astrophysics Data System (ADS)
Armitage, Philip J.; Reynolds, Christopher S.
2003-05-01
We use global magnetohydrodynamic simulations, in a pseudo-Newtonian potential, to investigate the temporal variability of accretion discs around Schwarzschild black holes. We use the vertically averaged magnetic stress in the simulated disc as a proxy for the rest-frame dissipation, and compute the observed emission by folding this through the transfer function describing the relativistic beaming, light bending and time delays near a non-rotating black hole. The temporal power spectrum of the predicted emission from individual annuli in the disc is described by a broken power law, with indices of ~-3.5 at high frequency and ~0 to -1 at low frequency. Integrated over the disc, the power spectrum is approximated by a single power law with an index of -2. Increasing inclination boosts the relative power at frequencies around ~0.3fms, where fms is the orbital frequency at the marginally stable orbit, but no evidence is found for sharp quasi-periodic oscillations in the light curve. Assuming that fluorescent iron line emission locally tracks the continuum flux, we compute simulated broad iron line profiles. We find that relativistic beaming of the non-axisymmetric emission profile, induced by turbulence, produces high-amplitude variability in the iron line profile. We show that this substructure within the broad iron line profile can survive averaging over a number of orbital periods, and discuss the origin of the anomalous X-ray spectral features, recently reported by Turner et al. for the Seyfert galaxy NGC 3516, in the context of turbulent disc models.
Sandhu, Simrenjeet; Rudnisky, Chris; Arora, Sourabh; Kassam, Faazil; Douglas, Gordon; Edwards, Marianne C; Verstraten, Karin; Wong, Beatrice; Damji, Karim F
2018-03-01
Clinicians can feel confident compressed three-dimensional digital (3DD) and two-dimensional digital (2DD) imaging evaluating important features of glaucomatous disc damage is comparable to the previous gold standard of stereoscopic slide film photography, supporting the use of digital imaging for teleglaucoma applications. To compare the sensitivity and specificity of 3DD and 2DD photography with stereo slide film in detecting glaucomatous optic nerve head features. This prospective, multireader validation study imaged and compressed glaucomatous, suspicious or normal optic nerves using a ratio of 16:1 into 3DD and 2DD (1024×1280 pixels) and compared both to stereo slide film. The primary outcome was vertical cup-to-disc ratio (VCDR) and secondary outcomes, including disc haemorrhage and notching, were also evaluated. Each format was graded randomly by four glaucoma specialists. A protocol was implemented for harmonising data including consensus-based interpretation as needed. There were 192 eyes imaged with each format. The mean VCDR for slide, 3DD and 2DD was 0.59±0.20, 0.60±0.18 and 0.62±0.17, respectively. The agreement of VCDR for 3DD versus film was κ=0.781 and for 2DD versus film was κ=0.69. Sensitivity (95.2%), specificity (95.2%) and area under the curve (AUC; 0.953) of 3DD imaging to detect notching were better (p=0.03) than for 2DD (90.5%; 88.6%; AUC=0.895). Similarly, sensitivity (77.8%), specificity (98.9%) and AUC (0.883) of 3DD to detect disc haemorrhage were better (p=0.049) than for 2DD (44.4%; 99.5%; AUC=0.72). There was no difference between 3DD and 2DD imaging in detecting disc tilt (p=0.7), peripapillary atrophy (p=0.16), grey crescent (p=0.1) or pallor (p=0.43), although 3D detected sloping better (p=0.013). Both 3DD and 2DD imaging demonstrates excellent reproducibility in comparison to stereo slide film with experts evaluating VCDR, notching and disc haemorrhage. 3DD in this study was slightly more accurate than 2DD for evaluating disc haemorrhage, notching and sloping. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Optomotor-blind negatively regulates Drosophila eye development by blocking Jak/STAT signaling.
Tsai, Yu-Chen; Grimm, Stefan; Chao, Ju-Lan; Wang, Shih-Chin; Hofmeyer, Kerstin; Shen, Jie; Eichinger, Fred; Michalopoulou, Theoni; Yao, Chi-Kuang; Chang, Chih-Hsuan; Lin, Shih-Han; Sun, Y Henry; Pflugfelder, Gert O
2015-01-01
Organ formation requires a delicate balance of positive and negative regulators. In Drosophila eye development, wingless (wg) is expressed at the lateral margins of the eye disc and serves to block retinal development. The T-box gene optomotor-blind (omb) is expressed in a similar pattern and is regulated by Wg. Omb mediates part of Wg activity in blocking eye development. Omb exerts its function primarily by blocking cell proliferation. These effects occur predominantly in the ventral margin. Our results suggest that the primary effect of Omb is the blocking of Jak/STAT signaling by repressing transcription of upd which encodes the Jak receptor ligand Unpaired.
Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun
2016-07-03
BACKGROUND The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. MATERIAL AND METHODS Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. RESULTS The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). CONCLUSIONS GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients.
Yang, Liu; Qu, Yuanzhen; Lu, Wen; Liu, Fengjun
2016-01-01
Background The aim of this study was to compare the differences in macular ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) in child and adult patients with primary craniopharyngioma by Fourier-domain optical coherence tomography (FD-OCT) and to evaluate their significance in the diagnosis of primary craniopharyngioma. Material/Methods Ninety-six participants were divided into 3 groups: 32 in the child craniopharyngioma group (CCG) and 32 in the adult craniopharyngioma group (ACG) who were treated in Beijing Tiantan Hospital between November 2013 and October 2014, and 32 in the normal group (NG). All subjects were scanned by FD-OCT to map GCC and pRNFL thicknesses. Spearman correlation coefficient was used to assess the correlation between GCC and pRNFL thickness, and pRNFL thickness and optic nerve head (ONH) parameters, including horizontal cup-disc ratio (HCDR), vertical cup-disc ratio (VCDR), optic disc area (ODA), and cup area (CA), respectively. Results The correlation between GCC and pRNFL thickness in the CCG was slightly stronger compared with the ACG. A significant difference in GCC thickness was observed among the CCG, ACG, and NG. Although the pRNFL thickness in both the CCG and ACG was significantly higher than that in NG, no significant difference in pRNFL thickness was detected between the 2 craniopharyngioma groups. The average, superior, and inferior pRNFL thicknesses were negatively correlated with VCDR in the CCG (in double eyes) and ACG (only in left eyes). Conclusions GCC was more sensitive than pRNFL in detecting optic nerve damage in the eyes of craniopharyngioma patients. A thinner pRNFL was especially correlated with VCDR in child craniopharyngioma patients. PMID:27372909
NASA Astrophysics Data System (ADS)
Gallo, L. C.; Blue, D. M.; Grupe, D.; Komossa, S.; Wilkins, D. R.
2018-05-01
The narrow-line Seyfert 1 galaxy (NLS1) Mrk 335 has been continuously monitored with Swift since May 2007 when it fell into a long-lasting, X-ray low-flux interval. Results from the nearly 11 years of monitoring are presented here. Structure functions are used to measure the UV-optical and X-ray power spectra. The X-ray structure function measured between 10 - 100 days is consistent with the flat, low-frequency part of the power spectrum measured previously in Mrk 335. The UV-optical structure functions of Mrk 335 are comparable with those of other Seyfert 1 galaxies and of Mrk 335 itself when it was in a normal bright state. There is no indication that the current X-ray low-flux state is attributed to changes in the accretion disc structure of Mrk 335. The characteristic timescales measured in the structure functions can be attributed to thermal (for the UV) and dynamic (for the optical) timescales in a standard accretion disc. The high-quality UVW2 (˜1800 Å in the source frame) structure function appears to have two breaks and two different slopes between 10 - 160 days. Correlations between the X-ray and other bands are not highly significant when considering the entire 11-year light curves, but more significant behaviour is present when considering segments of the light curves. A correlation between the X-ray and UVW2 in 2014 (Year-8) may be predominately caused by an giant X-ray flare that was interpreted as jet-like emission. In 2008 (Year-2), possible lags between the UVW2 emission and other UV-optical waveband may be consistent with reprocessing of X-ray or UV emission in the accretion disc.
Patel, Aarti; Purohit, Ravi; Lee, Helena; Sheth, Viral; Maconachie, Gail; Papageorgiou, Eleni; McLean, Rebecca J; Gottlob, Irene; Proudlock, Frank A
2016-10-01
To determine feasibility of optic nerve head (ONH) imaging and to characterize ONH development in full-term infants without sedation using handheld spectral-domain optical coherence tomography (SD OCT). Prospective cross-sectional study. Three hundred fifty-two children aged between 1 day and 13 years. All participants were imaged using handheld SD OCT without sedation during a single scan session. The percentage of successful scans was calculated. Interexaminer reproducibility and differences between right and left eyes were assessed using intraclass correlation coefficients (ICCs). Images were analyzed using ImageJ software. The developmental trajectories over time for ONH parameters were calculated using fractional polynomial modelling. Disc and cup diameter (expressed as distance in micrometers and visual angle in degrees), cup depth, Bruch's membrane opening-minimum rim width (BMO-MRW), retinal thickness, and retinal nerve fiber layer (RNFL; 1700 μm and 6° from the disc center). On average, 70% of participants were imaged successfully. Interexaminer reliability was excellent (ICC, >0.89) for diametric and retinal thickness parameters. Right and left eyes were similar for diametric measurements (ICC, >0.79), but more variable for nasal BMO-MRW, RNFL, and retinal thickness. The mean disc and cup diameter increase by 30% and 40%, respectively, between birth and 13 years of age when expressed as a distance measure, but remained constant (at 5°-5.5° and 2°, respectively) when expressed as a visual angle with reference to the eye nodal point. The peripapillary temporal RNFL demonstrated a marked initial decrease of nearly 35% between birth and approximately 18 months of age. This was followed by a slow increase up to 12 years of age when measured at 1700 μm from the disc center, although there was little change when measured at 6° from the disc center. We demonstrated feasibility of handheld SD OCT imaging of the ONH in full-term infants and children without anaesthesia or sedation. This is the first in vivo handheld SD OCT study to describe the development of ONH parameters during the critical early years of visual maturation. Our results provide a normative database for use in routine practice and further studies of ONH pathologic features. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
A Herschel resolved debris disc around HD 105211
NASA Astrophysics Data System (ADS)
Hengst, S.; Marshall, J. P.; Horner, J.; Marsden, S. C.
2017-07-01
Debris discs are the dusty aftermath of planet formation processes around main-sequence stars. Analysis of these discs is often hampered by the absence of any meaningful constraint on the location and spatial extent of the disc around its host star. Multi-wavelength, resolved imaging ameliorates the degeneracies inherent in the modelling process, making such data indispensable in the interpretation of these systems. The Herschel Space Observatory observed HD 105211 (η Cru, HIP 59072) with its Photodetector Array Camera and Spectrometer (PACS) instrument in three far-infrared wavebands (70, 100 and 160 μm). Here we combine these data with ancillary photometry spanning optical to far-infrared wavelengths in order to determine the extent of the circumstellar disc. The spectral energy distribution and multi-wavelength resolved emission of the disc are simultaneously modelled using a radiative transfer and imaging codes. Analysis of the Herschel/PACS images reveals the presence of extended structure in all three PACS images. From a radiative transfer model we derive a disc extent of 87.0 ± 2.5 au, with an inclination of 70.7 ± 2.2° to the line of sight and a position angle of 30.1 ± 0.5°. Deconvolution of the Herschel images reveals a potential asymmetry but this remains uncertain as a combined radiative transfer and image analysis replicates both the structure and the emission of the disc using a single axisymmetric annulus.
Resolving the disc-halo degeneracy - I: a look at NGC 628
NASA Astrophysics Data System (ADS)
Aniyan, S.; Freeman, K. C.; Arnaboldi, M.; Gerhard, O. E.; Coccato, L.; Fabricius, M.; Kuijken, K.; Merrifield, M.; Ponomareva, A. A.
2018-05-01
The decomposition of the rotation curve of galaxies into contribution from the disc and dark halo remains uncertain and depends on the adopted mass-to-light ratio (M/L) of the disc. Given the vertical velocity dispersion of stars and disc scale height, the disc surface mass density and hence the M/L can be estimated. We address a conceptual problem with previous measurements of the scale height and dispersion. When using this method, the dispersion and scale height must refer to the same population of stars. The scale height is obtained from near-infrared (IR) studies of edge-on galaxies and is weighted towards older kinematically hotter stars, whereas the dispersion obtained from integrated light in the optical bands includes stars of all ages. We aim to extract the dispersion for the hotter stars, so that it can then be used with the correct scale height to obtain the disc surface mass density. We use a sample of planetary nebulae (PNe) as dynamical tracers in the face-on galaxy NGC 628. We extract two different dispersions from its velocity histogram - representing the older and younger PNe. We also present complementary stellar absorption spectra in the inner regions of this galaxy and use a direct pixel fitting technique to extract the two components. Our analysis concludes that previous studies, which do not take account of the young disc, underestimate the disc surface mass density by a factor of ˜2. This is sufficient to make a maximal disc for NGC 628 appear like a submaximal disc.
SDSS-IV MaNGA: constraints on the conditions for star formation in galaxy discs
NASA Astrophysics Data System (ADS)
Stark, David V.; Bundy, Kevin A.; Orr, Matthew E.; Hopkins, Philip F.; Westfall, Kyle; Bershady, Matthew; Li, Cheng; Bizyaev, Dmitry; Masters, Karen L.; Weijmans, Anne-Marie; Lacerna, Ivan; Thomas, Daniel; Drory, Niv; Yan, Renbin; Zhang, Kai
2018-02-01
Regions of disc galaxies with widespread star formation tend to be both gravitationally unstable and self-shielded against ionizing radiation, whereas extended outer discs with little or no star formation tend to be stable and unshielded on average. We explore what drives the transition between these two regimes, specifically whether discs first meet the conditions for self-shielding (parametrized by dust optical depth, τ) or gravitational instability (parametrized by a modified version of Toomre's instability parameters, Qthermal, which quantifies the stability of a gas disc that is thermally supported at T = 104 K). We first introduce a new metric formed by the product of these quantities, Qthermalτ, which indicates whether the conditions for disc instability or self-shielding are easier to meet in a given region of a galaxy, and we discuss how Qthermalτ can be constrained even in the absence of direct gas information. We then analyse a sample of 13 galaxies with resolved gas measurements and find that on average galaxies will reach the threshold for disc instabilities (Qthermal < 1) before reaching the threshold for self-shielding (τ > 1). Using integral field spectroscopic observations of a sample of 236 galaxies from the Mapping Nearby Galaxies at APO (MaNGA) survey, we find that the value of Qthermalτ in star-forming discs is consistent with similar behaviour. These results support a scenario where disc fragmentation and collapse occurs before self-shielding, suggesting that gravitational instabilities are the primary condition for widespread star formation in galaxy discs. Our results support similar conclusions based on recent galaxy simulations.
Park, H-Yl; Hwang, Y S; Park, C K
2017-04-01
PurposeTo investigate the clinical characteristics according to the location of focal lamina cribrosa (LC) defects and its associated ocular features.Patients and methodsA total of 139 open-angle glaucoma patients underwent Spectralis optical coherence tomography (OCT) with enhanced depth imaging. Alterations in the contour of the LC were investigated to find focal LC defects. The location of the visible LC defect from the neural canal wall (far-peripheral and mid-peripheral) and clock-hour position (superotemporal, temporal and inferotemporal) were classified. Disc ovality ratio and disc-foveal angle were measured from disc and retinal nerve fiber layer (RNFL) photographs. The disc tilt degree was measured using a Heidelberg Retina Tomograph (HRT) III system. The en face OCT image of the disc scans was registered to the disc and RNFL photographs, to determine whether the focal LC defects corresponded spatially to the glaucomatous damage location.ResultsEyes with far-peripheral LC defects were significantly myopic and had a higher disc ovality ratio. The disc tilt degree obtained by HRT revealed significant temporal disc tilt in eyes with temporal LC defects (P<0.001). Eyes with inferotemporal LC defects had a significantly larger disc-foveal angle (P=0.027). The inferotemporal LC defects corresponded to the location of glaucomatous damage in 81.6%; however, only 46.2% of eyes with a superotemporal LC defect and 3.2% of eyes with a temporal LC defect corresponded spatially with the glaucomatous damage location.ConclusionsThe clinical characteristics and association with glaucomatous damage location were different according to the location of focal LC defect.
Adaptation of zirconia crowns created by conventional versus optical impression: in vitro study
Bahrami, Babak; Fossoyeux, InÈs; Atash, Ramin
2017-01-01
PURPOSE The aim of this study was to compare the precision of optical impression (Trios, 3Shape) versus that of conventional impression (Imprint IV, 3M-ESPE) with three different margins (shoulder, chamfer, and knife-edge) on Frasaco teeth. MATERIALS AND METHODS The sample comprised of 60 zirconia half-crowns, divided into six groups according to the type of impression and margin. Scanning electron microscopy enabled us to analyze the gap between the zirconia crowns and the Frasaco teeth, using ImageJ software, based on eight reproducible and standardized measuring points. RESULTS No statistically significant difference was found between conventional impressions and optical impressions, except for two of the eight points. A statistically significant difference was observed between the three margin types; the chamfer and knife-edge finishing lines appeared to offer better adaptation results than the shoulder margin. CONCLUSION Zirconia crowns created from optical impression and those created from conventional impression present similar adaptation. While offering identical results, the former have many advantages. In view of our findings, we believe the chamfer margin should be favored. PMID:28680553
Measurement of Optic Disc Cup Surface Depth Using Cirrus HD-OCT.
Kim, Young Kook; Ha, Ahnul; Lee, Won June; Jeoung, Jin Wook; Park, Ki Ho
2017-12-01
To introduce the measurement method of optic disc cup surface depth using spectral-domain optical coherence tomography (SD-OCT) and then evaluate the rates of cup surface depression at 3 different stages of glaucoma. We retrospectively identified 52 eyes with preperimetric glaucoma, 56 with mild-or-moderate glaucoma and 50 with severe glaucoma and followed them for at least 48 months. Eyes were imaged using SD-OCT (Cirrus HD-OCT) at 12-month intervals. The mean cup surface depth was calculated using the following formula: Cup volume/(disc area×average cup-to-disc ratio)-200 μm. The rates of mean cup surface depression (μm/y) were significantly greater in mild-or-moderate glaucoma (-7.96±1.03) than in preperimetric (-3.11±0.61) and severe glaucoma (-0.70±0.12; all P<0.001). The percentile rates of mean cup surface depression (%/y) were significantly greater than those of average of retinal nerve fiber layer (RNFL) thinning (%/y) in preperimetric glaucoma (-1.64±0.12 vs. -1.11±0.07; P<0.001) and mild-or-moderate glaucoma (-4.20±0.33 vs. -3.14±0.19; P<0.001); and conversely, in severe glaucoma, mean cup surface depth changed slower than did average RNFL thickness (-0.64±0.06 vs. -0.75±0.08%/y; P<0.001). In early-to-moderate glaucoma, the cup surface depth changed faster than did the RNFL thickness. These results signify the possibility that SD-OCT-based estimation of cup surface depth might be useful for monitoring of glaucoma development and progression.
Biomechanics of a Fixed–Center of Rotation Cervical Intervertebral Disc Prosthesis
Crawford, Neil R.; Baek, Seungwon; Sawa, Anna G.U.; Safavi-Abbasi, Sam; Sonntag, Volker K.H.; Duggal, Neil
2012-01-01
Background Past in vitro experiments studying artificial discs have focused on range of motion. It is also important to understand how artificial discs affect other biomechanical parameters, especially alterations to kinematics. The purpose of this in vitro investigation was to quantify how disc replacement with a ball-and-socket disc arthroplasty device (ProDisc-C; Synthes, West Chester, Pennsylvania) alters biomechanics of the spine relative to the normal condition (positive control) and simulated fusion (negative control). Methods Specimens were tested in multiple planes by use of pure moments under load control and again in displacement control during flexion-extension with a constant 70-N compressive follower load. Optical markers measured 3-dimensional vertebral motion, and a strain gauge array measured C4-5 facet loads. Results Range of motion and lax zone after disc replacement were not significantly different from normal values except during lateral bending, whereas plating significantly reduced motion in all loading modes (P < .002). Plating but not disc replacement shifted the location of the axis of rotation anteriorly relative to the intact condition (P < 0.01). Coupled axial rotation per degree of lateral bending was 25% ± 48% greater than normal after artificial disc replacement (P = .05) but 37% ± 38% less than normal after plating (P = .002). Coupled lateral bending per degree of axial rotation was 37% ± 21% less than normal after disc replacement (P < .001) and 41% ± 36% less than normal after plating (P = .001). Facet loads did not change significantly relative to normal after anterior plating or arthroplasty, except that facet loads were decreased during flexion in both conditions (P < .03). Conclusions In all parameters studied, deviations from normal biomechanics were less substantial after artificial disc placement than after anterior plating. PMID:25694869
A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements
NASA Astrophysics Data System (ADS)
Dennison, Christopher R.; Wild, Peter M.; Wilson, David R.; Cripton, Peter A.
2008-08-01
We present an in-fiber Bragg grating (FBG) based intervertebral disc (IVD) pressure sensor that has pressure sensitivity seven times greater than that of a bare fiber, and a major diameter and sensing area of only 400 µm and 0.03 mm2, respectively. This is the only optical, the smallest and the most mechanically compliant disc pressure sensor reported in the literature. This is also an improvement over other FBG pressure sensors that achieve increased sensitivity through mechanical amplification schemes, usually resulting in major diameters and sensing lengths of many millimeters. Sensor sensitivity is predicted using numerical models, and the predicted sensitivity is verified through experimental calibrations. The sensor is validated by conducting IVD pressure measurements in porcine discs and comparing the FBG measurements to those obtained using the current standard sensor for IVD pressure. The predicted sensitivity of the FBG sensor matched with that measured experimentally. IVD pressure measurements showed excellent repeatability and agreement with those obtained from the standard sensor. Unlike the current larger sensors, the FBG sensor could be used in discs with small disc height (i.e. cervical or degenerated discs). Therefore, there is potential to conduct new measurements that could lead to new understanding of the biomechanics.
A metallicity recipe for rocky planets
NASA Astrophysics Data System (ADS)
Dawson, Rebekah I.; Chiang, Eugene; Lee, Eve J.
2015-10-01
Planets with sizes between those of Earth and Neptune divide into two populations: purely rocky bodies whose atmospheres contribute negligibly to their sizes, and larger gas-enveloped planets possessing voluminous and optically thick atmospheres. We show that whether a planet forms rocky or gas-enveloped depends on the solid surface density of its parent disc. Assembly times for rocky cores are sensitive to disc solid surface density. Lower surface densities spawn smaller planetary embryos; to assemble a core of given mass, smaller embryos require more mergers between bodies farther apart and therefore exponentially longer formation times. Gas accretion simulations yield a rule of thumb that a rocky core must be at least 2M⊕ before it can acquire a volumetrically significant atmosphere from its parent nebula. In discs of low solid surface density, cores of such mass appear only after the gas disc has dissipated, and so remain purely rocky. Higher surface density discs breed massive cores more quickly, within the gas disc lifetime, and so produce gas-enveloped planets. We test model predictions against observations, using planet radius as an observational proxy for gas-to-rock content and host star metallicity as a proxy for disc solid surface density. Theory can explain the observation that metal-rich stars host predominantly gas-enveloped planets.
NASA Astrophysics Data System (ADS)
Omel'chenko, A. I.; Sobol', E. N.
2009-03-01
The thermomechanical effect of 1.56-μm fibre laser pulses on intervertebral disc cartilage has been studied using ac conductivity measurements with coaxial electrodes integrated with an optical fibre for laser radiation delivery to the tissue. The observed time dependences of tissue conductivity can be interpreted in terms of hydraulic effects and thermomechanical changes in tissue structure. The laserinduced changes in the electrical parameters of the tissue are shown to correlate with the structural changes, which were visualised using shadowgraph imaging. Local ac conductivity measurements in the bulk of tissue can be used to develop a diagnostic/monitoring system for laser regeneration of intervertebral discs.
X-ray and multiwavelength insights into the inner structure of high-luminosity disc-like emitters
NASA Astrophysics Data System (ADS)
Luo, B.; Brandt, W. N.; Eracleous, M.; Wu, Jian; Hall, P. B.; Rafiee, A.; Schneider, D. P.; Wu, Jianfeng
2013-02-01
We present X-ray and multiwavelength studies of a sample of eight high-luminosity active galactic nuclei (AGN) with disc-like Hβ emission-line profiles selected from the Sloan Digital Sky Survey Data Release 7. These sources have higher redshift (z ≈ 0.6) than the majority of the known disc-like emitters, and they occupy a largely unexplored space in the luminosity-redshift plane. Seven sources have typical AGN X-ray spectra with power-law photon indices of Γ ≈ 1.4-2.0; two of them show some X-ray absorption (column density NH ≈ 1021-1022 cm-2 for neutral gas). The other source, J0850+4451, has only three hard X-ray photons detected and is probably heavily obscured (NH ≳ 3 × 1023 cm-2). This object is also identified as a low-ionization broad absorption line (BAL) quasar based on Mg II λ2799 absorption; it is the first disc-like emitter reported that is also a BAL quasar. The infrared-to-ultraviolet (UV) spectral energy distributions (SEDs) of these eight sources are similar to the mean SEDs of typical quasars with a UV `bump', suggestive of standard accretion discs radiating with high efficiency, which differs from low-luminosity disc-like emitters. Studies of the X-ray-to-optical power-law slope parameters (αOX) indicate that there is no significant excess X-ray emission in these high-luminosity disc-like emitters. Energy budget analysis suggests that for disc-like emitters in general, the inner disc must illuminate and ionize the outer disc efficiently (≈15 per cent of the nuclear ionizing radiation is required on average) via direct illumination and/or scattering. Warped accretion discs are probably needed for direct illumination to work in high-luminosity objects, as their geometrically thin inner discs decrease the amount of direct illumination possible for a flat disc.
New Optical Card for Sneaker’s Network in Place of Electronic Clinical Record
NASA Astrophysics Data System (ADS)
Goto, Kenya; Satsukawa, Takatoshi; Chiba, Seisho; Ohmori, Takaaki
2006-02-01
In order to solve problems in electronic medical records, a new optical card of the digital versatile disk (DVD) type with higher capacity and lower cost than conventional compact disc recording (CD-R)-type cards has been developed, which is thinner, stronger and wearable like a credit card.
Thermodynamics of giant planet formation: shocking hot surfaces on circumplanetary discs
NASA Astrophysics Data System (ADS)
Szulágyi, J.; Mordasini, C.
2017-02-01
The luminosity of young giant planets can inform about their formation and accretion history. The directly imaged planets detected so far are consistent with the `hot-start' scenario of high entropy and luminosity. If nebular gas passes through a shock front before being accreted into a protoplanet, the entropy can be substantially altered. To investigate this, we present high-resolution, three-dimensional radiative hydrodynamic simulations of accreting giant planets. The accreted gas is found to fall with supersonic speed in the gap from the circumstellar disc's upper layers on to the surface of the circumplanetary disc and polar region of the protoplanet. There it shocks, creating an extended hot supercritical shock surface. This shock front is optically thick; therefore, it can conceal the planet's intrinsic luminosity beneath. The gas in the vertical influx has high entropy which when passing through the shock front decreases significantly while the gas becomes part of the disc and protoplanet. This shows that circumplanetary discs play a key role in regulating a planet's thermodynamic state. Our simulations furthermore indicate that around the shock surface extended regions of atomic - sometimes ionized - hydrogen develop. Therefore, circumplanetary disc shock surfaces could influence significantly the observational appearance of forming gas giants.
Deformation Recording Process In Polymer-Metal Bilayers And Its Use For Optical Storage
NASA Astrophysics Data System (ADS)
Cornet, Jean A.
1983-11-01
A non-antireflective polymer-metal bilayer structure, encapsulated inside a closed cons-truction/is used for digital data storage in the Thomson-CSF Gigadisc. In this paper, a simple model is presented for microdeformation recording in the medium. This model enables a good understanding of the readout signal as a function of the recording power and leads to some practical consequences. Useful polymers and metallic layers are identified and the disc performance is reported. It is shown that recording using laser diodes can be performed at bit rate up to 14 Mbits.s-1 with a laser power of 7 mW at the disc entry face, in case of a 1200 rpm disc speed. Moreover a working range of 4 mW, as defined by a 3 dB attenuation, is demonstrated. Discs from pilot production exhibit raw bit error rates at the level of 2.10-5. For usual environmental conditions, the disc behaviour is compatible with shelf-and archival life at scale of 10 years. Finally, the processes for both layers deposition and disc construction are easy and cost effective. It is concluded that Giaadisc can successfully enter today the market place.
NASA Astrophysics Data System (ADS)
Zhang, Dianxue; Cheng, Hefu; Wang, Jindong
2005-07-01
Objective: The possibility of PLDD (percutaneous laser disc decompression) and an ideal non-operative method which is long everlasting effect for PLDD was investigated. Methods: 159 patients of Cervical Disc Herniation with PLDD were studied. All the herniated discs were irradiated with 1015J/S Nd:YAG laser quantum through optical-fiber under the supervision of C-arm X-ray. Results: All the patients were followed and reexamined CT or MRI after one to six months of PLDD. The result of cured (67.92%), excellent (24.53%), moderation (5.66%), non-effect (1.88%) was got. The excellent rate was 88.24%. The effective rate was 97.65%. Non-effective rate was 2.35%. Conclusion: When irradiated with Nd:YAG laser, the nucleus pulposus was vapouring, charring and coagulating. The volume and inner-pressure of the disc decreased. So the symptoms and signs improved. The main value of this methods were micro-damage, non-operation, no bleeding, no bone injury, good therapy effect, quick recovery, lesser pain, safety and excellent long everlasting effect. It is an ideal non-operative method of treating PLDD.
Could Buerger's disease cause nonarteritic anterior ischemic optic neuropathy?: a rare case report.
Korkmaz, Anil; Karti, Omer; Top Karti, Dilek; Yüksel, Bora; Zengin, Mehmet Ozgur; Kusbeci, Tuncay
2018-04-05
We present an interesting case with nonarteritic anterior ischemic optic neuropathy (NAION) accompanied by Buerger's disease. A 43-year-old man was referred to our neuro-ophthalmology clinic with a complaint of visual deterioration in the left eye that started 5 days ago. He suffered from Buerger's disease, and he had acute pain in the right lower limb below the knee. His best corrected visual acuity was 10/10 in the right eye and 2/10 in the left eye by Snellen chart. There was a relative afferent pupil defect in the left eye. The right optic disc was normal on fundus examination, and blurring, hemorrhagic swelling was found at the left optic disc. Inferior altitudinal visual field defect was observed in the left eye. Neurological examination was normal. Computed tomography angiography scan revealed occlusion in the right posterior tibial artery. Brain imaging and laboratory tests such as blood analyses, genetic screening, coagulation, and lipid panels were unremarkable. NAION may occur in patients with Buerger's disease, but it is extremely rare. Therefore, clinicians should be aware of this rare association.
Electro thermal analysis of rotary type micro thermal actuator
NASA Astrophysics Data System (ADS)
Anwar, M. Arefin; Packirisamy, Muthukumaran; Ahmed, A. K. Waiz
2005-09-01
In micro domain, thermal actuators are favored because it provides higher force and deflection than others. This paper presents a new type of micro thermal actuator that provides rotary motion of the circular disc shaped cold arm, which can be used in various optical applications, such as, switching, attenuation, diffraction, etc. The device has been fabricated in MUMPS technology. In this new design, the hot arms are arranged with the cold disc in such a way that thermal expansion of the hot arms due to Joule heating, will make the cold disc to rotate and the rotation is unidirectional on loading. The dominant heat transfer modes in the operating temperature zone are through the anchor and the air between the structure and the substrate because of the very low gap provided by MUMPS. A mathematical model was used for predicting steady state temperature profile along the actuator length and rotational behavior of the cold disc under different applied voltages. A 3-D coupled field finite element analysis (FEM) for the device is also presented. A FEM analysis was done by defining an air volume around the structure and substrate below the structure. Results obtained from the mathematical model, was compared with that of the finite element analysis. The presented results confirm the applicability of this novel rotary type thermal actuator for many optical MEMS applications.
Pappas, Theofanis; Founti, Panayiota; Yin, Xiang Jun; Koskosas, Archimidis; Anastasopoulos, Eleftherios; Salonikiou, Angeliki; Kilintzis, Vasilios; Antoniadis, Antonios; Ziakas, Nikolaos; Topouzis, Fotis
2016-04-01
To compare Heidelberg Retina Tomograph (HRT) optic disc parameters and structure-function correlation between primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma (PEXG). Prospective, observation case series. A total of 54 POAG and 33 PEXG cases, consecutively recruited from a University Glaucoma Service, underwent a comprehensive ophthalmic examination, including HRT optic disc imaging. Glaucoma definition required the presence of both structural and functional damage. One eye per subject was included in the analysis. T test, Mann-Whitney U test, and analysis of covariance were used to compare HRT parameters between POAG and PEXG, adjusting for age, mean deviation (MD) in the visual field, intraocular pressure, and disc area. The correlation between HRT and MD was assessed in each group. Cup area (P=0.048), height variation contour (P=0.016), and cup/disc area ratio (P=0.023) were higher in POAG, whereas the mean retinal nerve fiber layer thickness (P=0.048), retinal nerve fiber layer cross-section area (P=0.044), and rim area (P=0.048) were lower in POAG, compared with PEXG. The correlation of HRT parameters with MD was significant only in the POAG group. At a similar level of functional damage, POAG subjects presented with more pronounced structural damage than PEXG subjects. The correlation between HRT and visual field parameters was more evident in POAG, compared with PEXG.
Skaat, Alon; Moroz, Iris; Moisseiev, Joseph
2013-01-01
To describe the different optical coherence tomography (OCT) patterns in macular detachment associated with an optic disc pit and their long-term evolution following vitrectomy. The data of 5 patients (9-43 years of age) with unilateral macular detachment associated with an optic disc pit, who had at least 1 year of follow-up, were compiled. Pars plana vitrectomy combined with gas tamponade was performed as the primary procedure in all patients. The OCT scans, best-corrected visual acuity (BCVA), and anatomic outcomes were documented. Two main OCT patterns were identified: a multilayer schisis pattern and a serous detachment pattern. Patients with multilayer schisis pattern were older and demonstrated worse mean preoperative (20/160) and postoperative (20/50) BCVA compared to serous detachment pattern patients (20/30 and 20/20, respectively). An average of 2.3 procedures per patient was needed in the multilayer schisis pattern compared to just one procedure in the serous detachment pattern. In 3 patients, additional pneumatic retinopexy was performed with full resolution of the subretinal fluid achieved. Two distinct OCT patterns were observed in eyes with macular detachments with an optic pit, with different clinical features and prognoses. Excellent final visual acuity was obtained in all eyes, including those that required several surgical procedures.
The effect of the menstrual cycle on optic nerve head analysis in healthy women.
Akar, Munire Erman; Taskin, Omur; Yucel, Iclal; Akar, Yusuf
2004-12-01
To determine the effect of the menstrual cycle on optic nerve head topographic analysis in normally menstruating, healthy women. The study included single eyes selected randomly from each of 52 healthy women with regular menstrual cycles. All subjects underwent a complete ocular examination. Optic nerve head topographic analyses were performed using a confocal scanning laser ophthalmoscope, the Heidelberg Retinal Tomograph II (HRT II, software version 1.6). The analyses were repeated three times during the menstrual cycle: in the follicular phase (days 7-10 of the cycle), at ovulation, and in the late luteal phase (days 1-3 before menstrual bleeding). Serum oestradiol, progesterone and luteinizing hormone levels were measured at each menstrual phase. Fourteen subjects were excluded from the study. The mean age of the subjects (n = 38) was 25.6 +/- 3.7 years (range 21-34 years). Blood oestradiol levels were significantly lower in the late luteal phase (35.8 pg/ml) (p < 0.0001). The mean disc area of the subjects was 1.94 +/- 0.33 mm(2). The neuroretinal rim area decreased significantly during the luteal phase (p < 0.001). However, the linear cup : disc ratio, cup : disc area ratio and the cup area were significantly higher during the luteal phase (p < 0.001). These observations raise the possibility that sex hormone fluctuations which occur during a normal menstrual cycle in healthy women significantly alter neuroretinal rim area and cup variables of the optic nerve head. These findings should be taken into consideration in the clinical follow-up of young women with glaucoma.
Pereira-Gurgel, Virginia M; Faro, Augusto C N; Salvatori, Roberto; Chagas, Thiago A; Carvalho-Junior, José F; Oliveira, Carla R P; Costa, Ursula M M; Melo, Gustavo B; Hellström, Ann; Aguiar-Oliveira, Manuel H
Experimental models demonstrate an important role of GH in retinal development. However, the interactions between GH and the neuro-vascularization of the human retina are still not clear. A model of untreated congenital isolated GH deficiency (IGHD) may clarify the actions of GH on the retina. The purpose of this work was to assess the retinal neuro-vascularization in untreated congenital IGHD (cIGHD). In a cross sectional study, we performed an endocrine and ophthalmological assessment of 25 adult cIGHD subjects, homozygous for a null mutation (c.57+1G>A) in the GHRH receptor gene and 28 matched controls. Intraocular pressure measurement, retinography (to assess the number of retinal vascular branching points and the optic disc and cup size), and optical coherence tomography (to assess the thickness of macula) were performed. cIGHD subjects presented a more significant reduction of vascular branching points in comparison to controls (91% vs. 53% [p=0.049]). The percentage of moderate reduction was higher in cIGHD than in controls (p=0.01). The percentage of individuals with increased optic disc was higher in cIGHD subjects in comparison to controls (92.9% vs. 57.1%). The same occurred for cup size (92.9% vs. 66.7%), p<0.0001 in both cases. There was no difference in macula thickness. Most cIGHD individuals present moderate reduction of vascular branching points, increase of optic disc and cup size, but have similar thickness of the macula. Copyright © 2016 Elsevier Ltd. All rights reserved.
The characterization of the distant blazar GB6 J1239+0443 from flaring and low activity periods
Pacciani, L.; Donnarumma, I.; Denney, K. D.; ...
2012-08-27
In 2008, AGILE and Fermi detected gamma-ray flaring activity from the unidentified EGRET source 3EG J1236+0457, recently associated with a flat spectrum radio quasar (GB6 J1239+0443) at z = 1.762. The optical counterpart of the gamma-ray source underwent a flux enhancement of a factor of 15–30 in six years, and of ~10 in six months. Here, we interpret this flare-up in terms of a transition from an accretion-disc-dominated emission to a synchrotron-jet-dominated one. We analysed a Sloan Digital Sky Survey (SDSS) archival optical spectrum taken during a period of low radio and optical activity of the source. We estimated themore » mass of the central black hole using the width of the C iv emission line. In our work, we have also investigated SDSS archival optical photometric data and ultraviolet GALEX observations to estimate the thermal disc emission contribution of GB6 J1239+0443. This analysis of the gamma-ray data taken during the flaring episodes indicates a flat gamma-ray spectrum, with an extension of up to 15 GeV, with no statistically relevant sign of absorption from the broad-line region, suggesting that the blazar zone is located beyond the broad-line region. Our result is confirmed by the modelling of the broad-band spectral energy distribution (well constrained by the available multiwavelength data) of the flaring activity periods and by the accretion disc luminosity and black hole mass estimated by us using archival data.« less
Macular slippage after macular hole surgery with internal limiting membrane peeling.
Nakagomi, Tomomi; Goto, Teruhiko; Tateno, Yasushi; Oshiro, Tomohiro; Iijima, Hiroyuki
2013-12-01
To describe macular slippage toward the optic disc after macular hole surgery with internal limiting membrane (ILM) peeling. A total of 27 eyes of 27 patients with idiopathic macular hole were included in this retrospective study. The fovea-to-disc distance (FDD) was measured from digital color fundus images before and at least six months after surgery. The position of the fovea was determined as the center of the macular hole before surgery and the center of the macular pigment area after surgery. The thickness of the nasal and temporal macula was measured using spectral-domain optical coherence tomography. The difference in thickness between the nasal and temporal macula was determined as the degree of parafoveal asymmetry (PFA). The postoperative FDD was significantly shorter than the preoperative FDD: 4.00 ± 0.33 mm and 3.82 ± 0.34 mm, respectively (p < 0.0001). The mean decreased ratio of FDD was 4.68% (range, 0.38-9.24%). The appearance of the dissociated optic nerve fiber layer (DONFL) was finally found in 21 eyes (78%). The decreased FDD ratio was significantly larger in eyes with the DONFL appearance than in those without it: 5.61 ± 1.74% and 1.44 ± 1.12%, respectively (p < 0.0001). The decreased ratio of FDD was correlated with the postoperative PFA (r = 0.63, p = 0.0004). A macula in which the ILM has peeled off would slip toward the optic disc after macular hole surgery. Macular slippage can be a reasonable cause for the macular alterations such as an appearance of DONFL and changes in asymmetrical parafoveal thickness.
Bae, Hyoung Won; Ji, Yongwoo; Lee, Hye Sun; Lee, Naeun; Hong, Samin; Seong, Gong Je; Sung, Kyung Rim; Kim, Chan Yun
2015-01-01
Normal-tension glaucoma (NTG) is a heterogenous disease, and there is still controversy about subclassifications of this disorder. On the basis of spectral-domain optical coherence tomography (SD-OCT), we subdivided NTG with hierarchical cluster analysis using optic nerve head (ONH) parameters and retinal nerve fiber layer (RNFL) thicknesses. A total of 200 eyes of 200 NTG patients between March 2011 and June 2012 underwent SD-OCT scans to measure ONH parameters and RNFL thicknesses. We classified NTG into homogenous subgroups based on these variables using a hierarchical cluster analysis, and compared clusters to evaluate diverse NTG characteristics. Three clusters were found after hierarchical cluster analysis. Cluster 1 (62 eyes) had the thickest RNFL and widest rim area, and showed early glaucoma features. Cluster 2 (60 eyes) was characterized by the largest cup/disc ratio and cup volume, and showed advanced glaucomatous damage. Cluster 3 (78 eyes) had small disc areas in SD-OCT and were comprised of patients with significantly younger age, longer axial length, and greater myopia than the other 2 groups. A hierarchical cluster analysis of SD-OCT scans divided NTG patients into 3 groups based upon ONH parameters and RNFL thicknesses. It is anticipated that the small disc area group comprised of younger and more myopic patients may show unique features unlike the other 2 groups.
Elleithy, Khaled; Elleithy, Abdelrahman
2018-01-01
Eye exam can be as efficacious as physical one in determining health concerns. Retina screening can be the very first clue for detecting a variety of hidden health issues including pre-diabetes and diabetes. Through the process of clinical diagnosis and prognosis; ophthalmologists rely heavily on the binary segmented version of retina fundus image; where the accuracy of segmented vessels, optic disc, and abnormal lesions extremely affects the diagnosis accuracy which in turn affect the subsequent clinical treatment steps. This paper proposes an automated retinal fundus image segmentation system composed of three segmentation subsystems follow same core segmentation algorithm. Despite of broad difference in features and characteristics; retinal vessels, optic disc, and exudate lesions are extracted by each subsystem without the need for texture analysis or synthesis. For sake of compact diagnosis and complete clinical insight, our proposed system can detect these anatomical structures in one session with high accuracy even in pathological retina images. The proposed system uses a robust hybrid segmentation algorithm combines adaptive fuzzy thresholding and mathematical morphology. The proposed system is validated using four benchmark datasets: DRIVE and STARE (vessels), DRISHTI-GS (optic disc), and DIARETDB1 (exudates lesions). Competitive segmentation performance is achieved, outperforming a variety of up-to-date systems and demonstrating the capacity to deal with other heterogeneous anatomical structures. PMID:29888146
Uddin, Rokon; Burger, Robert; Donolato, Marco; Fock, Jeppe; Creagh, Michael; Hansen, Mikkel Fougt; Boisen, Anja
2016-11-15
We present a biosensing platform for the detection of proteins based on agglutination of aptamer coated magnetic nano- or microbeads. The assay, from sample to answer, is integrated on an automated, low-cost microfluidic disc platform. This ensures fast and reliable results due to a minimum of manual steps involved. The detection of the target protein was achieved in two ways: (1) optomagnetic readout using magnetic nanobeads (MNBs); (2) optical imaging using magnetic microbeads (MMBs). The optomagnetic readout of agglutination is based on optical measurement of the dynamics of MNB aggregates whereas the imaging method is based on direct visualization and quantification of the average size of MMB aggregates. By enhancing magnetic particle agglutination via application of strong magnetic field pulses, we obtained identical limits of detection of 25pM with the same sample-to-answer time (15min 30s) using the two differently sized beads for the two detection methods. In both cases a sample volume of only 10µl is required. The demonstrated automation, low sample-to-answer time and portability of both detection instruments as well as integration of the assay on a low-cost disc are important steps for the implementation of these as portable tools in an out-of-lab setting. Copyright © 2016 Elsevier B.V. All rights reserved.
[Application of spectral optical coherent tomography (SOCT) in ophthalmology].
Bieganowski, Lech; Wojtkowski, Maciej; Kowalczyk, Andrzej; Kałuzny, Jakub J
2004-01-01
The article describes spectral optical coherent tomography (SOCT) constructed by Medical Physics Group, Faculty of Physics, Astronomy and Informatics at Nicholas Copernicus University in Toruń (Poland). It presents the physical bases for the functioning of the constructed device and includes pictures of optical sections of various elements of the eyeball: an optic disc and the region of central fovea, a cornea and angle structures (trabecular meshwork). The article also discusses potential application of SOCT in ophthalmic diagnosis of anterior and posterior segments of the eye.
Harnessing the Power of Light to See and Treat Breast Cancer
2014-10-01
effect of novel therapeutic agents in vivo. 15. SUBJECT TERMS optical spectroscopy, imaging , fiber-optic, molecular, screening, breast cancer 16...therapeutic agents in vivo. a. Original Statement of Work for 5 Years Aim 1: Optical imaging of margin morphology on breast lumpectomy specimens: To...evaluate the role of wide-field imaging (coverage) and high-resolution interrogation (localization) of breast margin morphology to guide surgical
Saarela, Ville; Falck, Aura; Airaksinen, P Juhani; Tuulonen, Anja
2012-03-01
To evaluate the factors affecting the sensitivity and specificity of the stereometric optic nerve head (ONH) parameters of the Heidelberg Retina Tomograph (HRT) to glaucomatous progression in stereoscopic ONH photographs. The factors affecting the sensitivity and specificity of the vertical cup : disc ratio, the cup : disc area ratio, the cup volume, the rim area and a linear discriminant function to progression were analysed. These parameters were the best indicators of progression in a retrospective study of 476 eyes. The reference standard for progression was the masked evaluation of stereoscopic ONH photographs. The factors having the most significant effect on the sensitivity and specificity of the stereometric ONH parameters were the reference height difference and the mean topography standard deviation (TSD), indicating image quality. Also, the change in the TSD and age showed consistent, but variably significant, influence on all parameters tested. The sensitivity and specificity improved when there was little change in the reference height, the image quality was good and stable, and the patients were younger. The sensitivity and specificity of the vertical cup : disc ratio was improved by a large disc area and high baseline cup : disc area ratio. The rim area showed a better sensitivity and specificity for progression with a small disc area and low baseline cup : disc area ratio. The factors affecting the sensitivity and specificity of the stereometric ONH parameters to glaucomatous progression in disc photographs are essentially the same as those affecting the measurement variability of the HRT. © 2010 The Authors. Acta Ophthalmologica © 2010 Acta Ophthalmologica Scandinavica Foundation.
Herzog, Bernd; Katzenstein, Armin; Quass, Katja; Stehlin, Albert; Luther, Helmut
2004-03-01
In this study microparticles consisting of a benzotriazole derivative, which are used as absorbers for UV radiation in cosmetic sunscreens, were investigated. The particles were micronized in presence of a dispersing agent by means of a ball milling process. According to the energy input different particle sizes were produced in the range of 0.16 to 4 microm. The particle sizes obtained after different stages of the micronization process were measured using fiber-optic quasi-elastic light scattering (FOQELS), disc centrifugation, and laser diffractometry. All methods showed satisfactory agreement over the whole range of sizes. With the FOQELS technique the particle size distribution could be resolved to sizes well below 0.1 microm.
An inner warp in the DoAr 44 T Tauri transition disc
NASA Astrophysics Data System (ADS)
Casassus, Simon; Avenhaus, Henning; Pérez, Sebastián; Navarro, Víctor; Cárcamo, Miguel; Marino, Sebastián; Cieza, Lucas; Quanz, Sascha P.; Alarcón, Felipe; Zurlo, Alice; Osses, Axel; Rannou, Fernando R.; Román, Pablo E.; Barraza, Marcelo
2018-07-01
Optical/IR images of transition discs (TDs) have revealed deep intensity decrements in the rings of HAeBes HD 142527 and HD 100453 that can be interpreted as shadowing from sharply tilted inner discs, such that the outer discs are directly exposed to stellar light. Here we report similar dips in SPHERE+IRDIS differential polarized imaging (DPI) of T Tauri DoAr 44. With a fairly axially symmetric ring in the sub-mm radio continuum, DoAr 44 is likely also a warped system. We constrain the warp geometry by comparing radiative transfer predictions with the DPI data in H band (Qϕ(H)) and with a re-processing of archival 336 GHz ALMA observations. The observed DPI shadows have coincident radio counterparts, but the intensity drops are much deeper in Qϕ(H) (˜88 per cent), compared to the shallow drops at 336 GHz (˜24 per cent). Radiative transfer predictions with an inner disc tilt of ˜30 ± 5 deg approximately account for the observations. ALMA long-baseline observations should allow the observation of the warped gas kinematics inside the cavity of DoAr 44.
Is there a UV/X-ray connection in IRAS 13224-3809?
NASA Astrophysics Data System (ADS)
Buisson, D. J. K.; Lohfink, A. M.; Alston, W. N.; Cackett, E. M.; Chiang, C.-Y.; Dauser, T.; De Marco, B.; Fabian, A. C.; Gallo, L. C.; García, J. A.; Jiang, J.; Kara, E.; Middleton, M. J.; Miniutti, G.; Parker, M. L.; Pinto, C.; Uttley, P.; Walton, D. J.; Wilkins, D. R.
2018-04-01
We present results from the optical, ultraviolet, and X-ray monitoring of the NLS1 galaxy IRAS 13224-3809 taken with Swift and XMM-Newton during 2016. IRAS 13224-3809 is the most variable bright AGN in the X-ray sky and shows strong X-ray reflection, implying that the X-rays strongly illuminate the inner disc. Therefore, it is a good candidate to study the relationship between coronal X-ray and disc UV emission. However, we find no correlation between the X-ray and UV flux over the available ˜40 d monitoring, despite the presence of strong X-ray variability and the variable part of the UV spectrum being consistent with irradiation of a standard thin disc. This means either that the X-ray flux which irradiates the UV emitting outer disc does not correlate with the X-ray flux in our line of sight and/or that another process drives the majority of the UV variability. The former case may be due to changes in coronal geometry, absorption or scattering between the corona and the disc.
Deep Fabry-Perot Hα observations of two Sculptor group galaxies, NGC 247 and 300
NASA Astrophysics Data System (ADS)
Hlavacek-Larrondo, J.; Marcelin, M.; Epinat, B.; Carignan, C.; de Denus-Baillargeon, M.-M.; Daigle, O.; Hernandez, O.
2011-09-01
It has been suggested that diffuse ionized gas can extend all the way to the end of the H I disc, and even beyond, such as in the case of the warped galaxyNGC 253 (Bland-Hawthorn et al.). Detecting ionized gas at these radii could carry significant implications as to the distribution of dark matter in galaxies. With the aim of detecting this gas, we carried out a deep Hα kinematical analysis of two Sculptor group galaxies, NGC 247 and 300. The Fabry-Perot data were taken at the 36-cm Marseille Telescope in La Silla, Chile, offering a large field of view. With almost 20 hours of observations for each galaxy, very faint diffuse emission is detected. Typical emission measures of 0.1 cm-6 pc are reached. For NGC 247, emission extending up to a radius comparable with that of the H I disc (r˜ 13 arcmin) is found, but no emission is seen beyond the H I disc. For NGC 300, we detect ionized gas on the entirety of our field of view (rmax˜ 14 arcmin), and find that the bright H II regions are embedded in a diffuse background. Using the deep data, extended optical rotation curves are obtained, as well as mass models. These are the most extended optical rotation curves thus far for these galaxies. We find no evidence suggesting that NGC 247 has a warped disc, and to account for our non-detection of Hα emission beyond its H I disc, as opposed to the warped galaxy NGC 253, our results favour the model in which, only through a warp, ionization by hot young stars in the central region of a galaxy can let photons escape and ionize the interstellar medium in the outer parts.
Multi-wavelength properties of two supersoft X-ray sources CAL83 and RXJ0513.9-6951
NASA Astrophysics Data System (ADS)
Rajoelimanana, A.; Meintjes, P.; Charles, P.
2017-10-01
Supersoft X-ray sources (SSS) are highly luminous (˜10^{38} erg s^{-1}), yet low temperature 10^{6} K sources, interpreted as a white dwarf (WD) accreting matter at a very high rate from its (heavy) companion, leading to Eddington-limited, steady hydrogen burning on the WD surface at T˜15-80 eV. A large fraction of this energy irradiates the surface of the disc, which gives rise to a reprocessed flux much larger than the intrinsic disc luminosity, accounting for the large optical and UV fluxes detected in SSS. We present the multi-wavelength properties of two prototypical LMC SSS, CAL83 and RXJ0513.9-6951, with particular emphasis on the anti-correlation between their X-ray and optical behaviour. Our SALT spectra show variable high excitation OVI emission as a function of optical brightness state, and which we link to the cyclic changes in the temperature and size of the WD, and hence the mass accretion rate.
Morning glory syndrome associated with primary open angle glaucoma--case report.
Bozić, Marija; Hentova-Senćanić, Paraskeva; Marković, Vujica; Marjanović, Ivan
2014-01-01
Morning glory syndrome (MGS) is a rare congenital optic disc anomaly, first reported in 1970. MGS is a nonprogressive and untreatable condition, which usually occurs as an isolated ocular anomaly, and can be associated with the increased incidence of nonrhegmatogenous retinal detachment, and also with strabismus, afferent pupillary defect, visual field defects, presence of hyaloids artery remnants, ciliary body cyst, congenital cataract, lid hemangioma and preretinal gliosis. We report a clinical case of MGS associated with primary open angle glaucoma. The use of sophisticated diagnostic tools, such as retinal tomography and visual field testing is limited if multiple eye conditions are present, since optic disc does not have "usual" appearance that can be analyzed according to standard statistical databases. In treating and follow up of glaucoma cases associated with other diseases and conditions that affect the appearance and function of the optic nerve head, sometimes the use of modern technological methods is limited due to difficult interpretation of the obtained results.
Risk of Microgravity-Induced Visual Impairment and Elevated Intracranial Pressure (VIIP)
NASA Technical Reports Server (NTRS)
Otto, Christian
2011-01-01
Eight cases identified, represent 23.5% of the 34 crewmembers flown on the ISS, with inflight visual changes and pre-to-postflight refractive changes. In some cases, the changes were transient while in others they are persistent with varying degrees of visual impairment. (1) Decreased intraocular pressure (IOP) postflight was observed in 3 cases. (2) Fundoscopic exams revealed postflight findings of choroidal folds in 4 cases, optic disc edema in 5 cases and presence of cotton wool spots in 3 cases. (3) Optical coherence tomography (OCT) confirmed findings of choroidal folds and disc edema and documented retinal nerve fiber layer thickening (4 cases). (4) Findings from MRI examinations showed posterior globe flattening (5 cases) and optic nerve sheath distension (6 cases). (5) Opening cerebrospinal fluid (CSF) pressure was elevated in 4 cases postflight reflecting raised intracranial pressure. While the etiology remains unknown, hypotheses speculate that venous insufficiency or hypertension in the brain caused by cephalad fluid shifts during spaceflight are possible mechanisms for ocular changes in astronauts.
Application of phase-change materials in memory taxonomy
Wang, Lei; Tu, Liang; Wen, Jing
2017-01-01
Abstract Phase-change materials are suitable for data storage because they exhibit reversible transitions between crystalline and amorphous states that have distinguishable electrical and optical properties. Consequently, these materials find applications in diverse memory devices ranging from conventional optical discs to emerging nanophotonic devices. Current research efforts are mostly devoted to phase-change random access memory, whereas the applications of phase-change materials in other types of memory devices are rarely reported. Here we review the physical principles of phase-change materials and devices aiming to help researchers understand the concept of phase-change memory. We classify phase-change memory devices into phase-change optical disc, phase-change scanning probe memory, phase-change random access memory, and phase-change nanophotonic device, according to their locations in memory hierarchy. For each device type we discuss the physical principles in conjunction with merits and weakness for data storage applications. We also outline state-of-the-art technologies and future prospects. PMID:28740557
Tan, Fa-Bing; Wang, Lu; Fu, Gang; Wu, Shu-Hong; Jin, Ping
2010-02-01
To study the effect of different optical impression methods in Cerec 3D/Inlab MC XL system on marginal and internal fit of all-ceramic crowns. A right mandibular first molar in the standard model was used to prepare full crown and replicated into thirty-two plaster casts. Sixteen of them were selected randomly for bonding crown and the others were used for taking optical impression, in half of which the direct optical impression taking method were used and the others were used for the indirect method, and then eight Cerec Blocs all-ceramic crowns were manufactured respectively. The fit of all-ceramic crowns were evaluated by modified United States Public Health Service (USPHS) criteria and scanning electron microscope (SEM) imaging, and the data were statistically analyzed with SAS 9.1 software. The clinically acceptable rate for all marginal measurement sites was 87.5% according to USPHS criteria. There was no statistically significant difference in marginal fit between direct and indirect method group (P > 0.05). With SEM imaging, all marginal measurement sites were less than 120 microm and no statistically significant difference was found between direct and indirect method group in terms of marginal or internal fit (P > 0.05). But the direct method group showed better fit than indirect method group in terms of mesial surface, lingual surface, buccal surface and occlusal surface (P < 0.05). The distal surface's fit was worse and the obvious difference was observed between mesial surface and distal surface in direct method group (P < 0.01). Under the conditions of this study, the optical impression method had no significant effect on marginal fit of Cerec Blocs crowns, but it had certain effect on internal fit. Overall all-ceramic crowns appeared to have clinically acceptable marginal fit.
Optomotor-Blind Negatively Regulates Drosophila Eye Development by Blocking Jak/STAT Signaling
Tsai, Yu-Chen; Grimm, Stefan; Chao, Ju-Lan; Wang, Shih-Chin; Hofmeyer, Kerstin; Shen, Jie; Eichinger, Fred; Michalopoulou, Theoni; Yao, Chi-Kuang; Chang, Chih-Hsuan; Lin, Shih-Han; Sun, Y. Henry; Pflugfelder, Gert O.
2015-01-01
Organ formation requires a delicate balance of positive and negative regulators. In Drosophila eye development, wingless (wg) is expressed at the lateral margins of the eye disc and serves to block retinal development. The T-box gene optomotor-blind (omb) is expressed in a similar pattern and is regulated by Wg. Omb mediates part of Wg activity in blocking eye development. Omb exerts its function primarily by blocking cell proliferation. These effects occur predominantly in the ventral margin. Our results suggest that the primary effect of Omb is the blocking of Jak/STAT signaling by repressing transcription of upd which encodes the Jak receptor ligand Unpaired. PMID:25781970
Code of Federal Regulations, 2010 CFR
2010-01-01
..., electronic tapes and back-up tapes, optical discs, CD-ROMS, and DVDs), and voicemail records; (2) Where the information is stored or located, including network servers, desktop or laptop computers and handheld...
Topographical analysis of corneal astigmatism in patients with tilted-disc syndrome.
Bozkurt, Banu; Irkec, Murat; Gedik, Sansal; Orhan, Mehmet; Erdener, Uğur
2002-07-01
To evaluate the corneal topography in patients with tilted-disc syndrome to determine the relationship between optic disc dysversion and corneal astigmatism and the pattern of astigmatism in these patients. The study included 23 eyes of the 13 tilted-disc syndrome patients with spheric refractive errors ranging between +1.00 D and -9.00 D (mean -4.00 +/- 3.4 D) and astigmatic errors ranging between -0.50 and -4.50 D (mean -1.95 +/- 0.93 D). Corneal topography was performed by computer-assisted videokeratoscope topographic modelling system 2 (TMS-2) and incidence of corneal astigmatism, corneal topographic patterns, and mean values of the topographic indices were determined. Corneal topographic analysis showed corneal astigmatism in 22 out of 23 patients with tilted discs. Corneal astigmatism was symmetric bow tie pattern in 10 eyes (45.45%), asymmetric bow tie pattern in 11 eyes (50%) and irregular in 1 eye (4.5%). Among the patients with bow tie pattern group (21 eyes), 14 eyes had with-the-rule astigmatism, 1 eye had against-the-rule astigmatism, and 6 eyes had oblique astigmatism. In 18 eyes, astigmatism was corneal, whereas combined corneal and lenticular in 4 eyes and lenticular in 1 eye. In the majority of tilted-disc cases, ocular astigmatism is mainly corneal. Morphogenetic factors in the development of the tilted disc might possibly influence the corneal development in such a way to result in corneal astigmatism.
NASA Astrophysics Data System (ADS)
Sirelkhatim, Amna; Mahmud, Shahrom; Seeni, Azman; Kaus, Noor Haida Mohd.; Sendi, Rabab
2014-10-01
In this study, we investigated physico-chemical properties of zinc oxide nanoparticles (ZnO NPs)-based discs and their toxicity on human cervical cancer HeLa cell lines. ZnO NPs (80 nm) were produced by the conventional ceramic processing method. FESEM analysis indicated dominant structure of nanorods with dimensions 100-500 nm in length, and 20-100 nm in diameter. The high content of ZnO nanorods in the discs probably played significant role in toxicity towards HeLa cells. Structural defects (oxygen vacancies and zinc/oxygen interstitials) were revealed by PL spectra peaks at 370-376 nm and 519-533 nm for the ZnO discs. The structural, optical and electrical properties of prepared sample have influenced the toxicological effects of ZnO discs towards HeLa cell lines via the generation of reactive oxygen species (ROS), internalization, membrane damage, and eventually cell death. The larger surface to volume area of the ZnO nanorods, combined with defects, stimulated enhanced toxicity via ROS generation hydrogen peroxide, hydroxyl radicals, and superoxide anion. The preliminary results confirmed the ZnO-disc toxicity on HeLa cells was significantly associated with the unique physicochemical properties of ZnO NPs and to our knowledge, this is the first cellular study for treatment of HeLa cells with ZnO discs made from 80 nm ZnO particles.
NASA Astrophysics Data System (ADS)
Baglio, M. C.; D'Avanzo, P.; Muñoz-Darias, T.; Breton, R. P.; Campana, S.
2013-11-01
Aims: We present a study of the quiescent optical counterpart of the accreting millisecond X-ray pulsar XTE J1814-338 that is aimed at unveiling the different components, which contribute to the quiescent optical emission of the system. Methods: We carried out multiband (BVR) orbital phase-resolved photometry of the system using the ESO Very Large Telescope (VLT) that is equipped with the FORS2 camera, covering about 70% of the 4.3 hour orbital period. Results: The optical light curves are consistent with a sinusoidal variability that are modulated with an orbital period with a semi-amplitude of 0.5-0.7 mag. They show evidence of a strongly irradiated companion star, which agrees with previous findings for this system. However, the observed colours cannot be accounted for by the companion star alone, suggesting the presence of an accretion disc during quiescence. The system seems to be fainter in all analysed bands compared to previous observations. The R band light curve displays a possible phase offset with respect to the B and V band. Through a combined fit of the multi-band light curve performed with a Markov chain Monte Carlo technique, we derive constraints on the companion star, disc fluxes, system distance, and companion star mass. Conclusions: The irradiation luminosity required to account for the observed day-side temperature of the companion star is consistent with the spin-down luminosity of a millisecond radio pulsar. Compared to our data with previous observations, which were collected over 5 years, the flux decrease and spectral evolution of the observed quiescent optical emission cannot be satisfactorily explained with the combined contribution of an irradiated companion star and of an accretion disc alone. The observed progressive flux decrease as the system gets bluer could be due to a continuum component that evolves towards a lower, bluer spectrum. While most of the continuum component is likely due to the disc, we do not expect it to become bluer in quiescence. Hence, we hypothesize that an additional component, such as synchrotron emission from a jet was significantly contributing in the data obtained earlier during quiescence and then progressively fading or moving its break frequency towards longer wavelengths. Based on observations made with ESO Telescopes at the Paranal Observatory under programme ID 383.D-0730(A).
Circular geodesic of Bardeen and Ayon-Beato-Garcia regular black-hole and no-horizon spacetimes
NASA Astrophysics Data System (ADS)
Stuchlík, Zdeněk; Schee, Jan
2015-12-01
In this paper, we study circular geodesic motion of test particles and photons in the Bardeen and Ayon-Beato-Garcia (ABG) geometry describing spherically symmetric regular black-hole or no-horizon spacetimes. While the Bardeen geometry is not exact solution of Einstein's equations, the ABG spacetime is related to self-gravitating charged sources governed by Einstein's gravity and nonlinear electrodynamics. They both are characterized by the mass parameter m and the charge parameter g. We demonstrate that in similarity to the Reissner-Nordstrom (RN) naked singularity spacetimes an antigravity static sphere should exist in all the no-horizon Bardeen and ABG solutions that can be surrounded by a Keplerian accretion disc. However, contrary to the RN naked singularity spacetimes, the ABG no-horizon spacetimes with parameter g/m > 2 can contain also an additional inner Keplerian disc hidden under the static antigravity sphere. Properties of the geodesic structure are reflected by simple observationally relevant optical phenomena. We give silhouette of the regular black-hole and no-horizon spacetimes, and profiled spectral lines generated by Keplerian rings radiating at a fixed frequency and located in strong gravity region at or nearby the marginally stable circular geodesics. We demonstrate that the profiled spectral lines related to the regular black-holes are qualitatively similar to those of the Schwarzschild black-holes, giving only small quantitative differences. On the other hand, the regular no-horizon spacetimes give clear qualitative signatures of their presence while compared to the Schwarschild spacetimes. Moreover, it is possible to distinguish the Bardeen and ABG no-horizon spacetimes, if the inclination angle to the observer is known.
The lamppost model: effects of photon trapping, the bottom lamp and disc truncation
NASA Astrophysics Data System (ADS)
Niedźwiecki, Andrzej; Zdziarski, Andrzej A.
2018-04-01
We study the lamppost model, in which the primary X-ray sources in accreting black-hole systems are located symmetrically on the rotation axis on both sides of the black hole surrounded by an accretion disc. We show the importance of the emission of the source on the opposite side to the observer. Due to gravitational light bending, its emission can increase the direct (i.e., not re-emitted by the disc) flux by as much as an order of magnitude. This happens for near to face-on observers when the disc is even moderately truncated. For truncated discs, we also consider effects of emission of the top source gravitationally bent around the black hole. We also present results for the attenuation of the observed radiation with respect to that emitted by the lamppost as functions of the lamppost height, black-hole spin and the degree of disc truncation. This attenuation, which is due to the time dilation, gravitational redshift and the loss of photons crossing the black-hole horizon, can be as severe as by several orders of magnitude for low lamppost heights. We also consider the contribution to the observed flux due to re-emission by optically-thick matter within the innermost stable circular orbit.
Automated retinal vessel type classification in color fundus images
NASA Astrophysics Data System (ADS)
Yu, H.; Barriga, S.; Agurto, C.; Nemeth, S.; Bauman, W.; Soliz, P.
2013-02-01
Automated retinal vessel type classification is an essential first step toward machine-based quantitative measurement of various vessel topological parameters and identifying vessel abnormalities and alternations in cardiovascular disease risk analysis. This paper presents a new and accurate automatic artery and vein classification method developed for arteriolar-to-venular width ratio (AVR) and artery and vein tortuosity measurements in regions of interest (ROI) of 1.5 and 2.5 optic disc diameters from the disc center, respectively. This method includes illumination normalization, automatic optic disc detection and retinal vessel segmentation, feature extraction, and a partial least squares (PLS) classification. Normalized multi-color information, color variation, and multi-scale morphological features are extracted on each vessel segment. We trained the algorithm on a set of 51 color fundus images using manually marked arteries and veins. We tested the proposed method in a previously unseen test data set consisting of 42 images. We obtained an area under the ROC curve (AUC) of 93.7% in the ROI of AVR measurement and 91.5% of AUC in the ROI of tortuosity measurement. The proposed AV classification method has the potential to assist automatic cardiovascular disease early detection and risk analysis.
NASA Astrophysics Data System (ADS)
Ricci, T. V.; Steiner, J. E.; May, D.; Garcia-Rissmann, A.; Menezes, R. B.
2018-02-01
NGC 7582 is an SB(s)ab galaxy which displays evidences of simultaneous nuclear activity and star formation in its centre. Previous optical observations revealed, besides the H II regions, an ionization cone and a gas disc in its central part. Hubble Space Telescope (HST) images in both optical and infrared bands show the active galactic nuclei (AGNs) and a few compact structures that are possibly associated with young stellar clusters. In order to study in detail both the AGN and evidence for star formation, we analyse optical (Gemini Multi-Object Spectrograph) and near-infrared (Spectrograph for Integral Field Observations in the Near Infrared) archival data cubes. We detected five nebulae with strong He II λ4686 emission in the same region where an outflow is detected in the [O III] λ5007 kinematic map. We interpreted this result as clouds that are exposed to high-energy photons emerging from the AGN throughout the ionization cone. We also detected Wolf-Rayet features which are related to emission of one of the compact clusters seen in the HST image. Broad Hα and Br γ components are detected at the position of the nucleus. [Fe II] λ1.644 μm, H2λ2.122 μm and Br γ flux maps show two blobs, one north and the other south from the nucleus, that seem to be associated with five previously detected mid-infrared sources. Two of the five He II nebulae are partially ionized by photons from starbursts. However, we conclude that the main source of excitation of these blobs is the AGN jet/disc. The jet orientation indicates that the accretion disc is nearly orthogonal to the dusty torus.
Chansangpetch, Sunee; Huang, Guofu; Coh, Paul; Oldenburg, Catherine; Amoozgar, Behzad; He, Mingguang; Lin, Shan C
2018-04-01
To compare optic nerve head, peripapillary retinal nerve fiber layer (pRNFL), and ganglion cell complex (GCC) parameters between Caucasian and ethnic Chinese. Normal subjects above 40 years old and self-identified as being Caucasian and Chinese were recruited. They were evaluated with spectral-domain optical coherence tomography (RTVue-100). Parameters related to the optic nerve head, pRNFL, and GCC analysis protocols were acquired. Multivariable linear regression was performed adjusting for potential confounders. Data from 116 Caucasian and 130 Chinese subjects were available for analysis. Mean age of all participants was 66.72 (SD 10.82) years. There were statistically significant differences for disc area (DA), area cup-to-disc, vertical cup-to-disc, and cup volume (P=0.02, 0.004, 0.02, and 0.03, respectively), greater in Chinese. After adjusting for age, sex, axial length (AL), intraocular pressure (IOP), DA, and GCC thickness, Chinese subjects had significantly greater thickness in all pRNFL parameters (mean differences ranged between 4.29 and 9.93 μm; all P<0.001) except the nasal quadrant. GCC outcomes were also adjusted for DA and pRNFL; Caucasians had significantly higher average GCC and inferior GCC (mean difference 2.97 and 3.45 μm, respectively; P<0.01), whereas the Chinese group had significantly higher ganglion cell global loss volume (mean difference 2.47 %, P<0.001). This study suggests there is significantly greater pRNFL thickness in Chinese, which were independent of age, AL, IOP, and DA, and possibly greater GCC in Caucasians after adjustment for age, AL, IOP, DA, and pRNFL thickness.
Ocular dimensions in relation to auxological data in a sample of Swedish children aged 4-15 years.
Raffa, Lina H; Hellström, Ann; Aring, Eva; Andersson, Susann; Grönlund, Marita Andersson
2014-11-01
The purpose was to characterize normal growth patterns of ocular and optical components and to relate them to auxological data in a sample of Swedish children aged 4-15 years. A prospective cross-sectional study was carried out in 143 Swedish children with a mean age of 9.8 years. Variables including gestational age (GA), weight, length and head circumference (HCF) at birth and at the time of assessment were registered. Visual acuity (VA), cycloplegic refraction and biometric measures were obtained. Palpebral fissure length and inner canthal distance were measured. Optic disc morphology as seen on fundus photographs was analysed. Children born more mature, with male predilection, were found to have deeper anterior and vitreous chamber depths, longer axial lengths and thinner crystalline lens thickness. No correlations were found between ocular biometric measurements and VA or refraction after adjustment for confounding variables. Inner canthal distance was significantly correlated with birth length (p = 0.03), height, weight, BMI and HCF (p = 0.0008, p = 0.0007, p = 0.037, and p = 0.04, respectively) at time of assessment. Total axial length was found to be significantly correlated with GA (p = 0.0226) and length at assessment in girls (p = 0.0084). Right optic disc and rim areas decreased with increasing age (p = 0.0078 and p = 0.0107, respectively); however, optic disc parameters were not dependent on any other variable. These normative values may serve as a basis for the ocular findings and their relationship to auxological data in Caucasian children aged 4-15 years, as well as for future comparison in patients with paediatric ocular pathologies. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Harnessing the Power of Light to See and Treat Breast Cancer
2012-10-01
informed approach to study tumor biology and assay the effect of novel therapeutic agents in vivo. 15. SUBJECT TERMS optical spectroscopy, imaging , fiber...Statement of Work for 5 Years Aim 1: Optical imaging of margin morphology on breast lumpectomy specimens: To evaluate the role of wide-field imaging ...assessment of the tumor margin post-operatively (Timeframe: year 1-5). 1a. Development of one optical spectral imaging system that integrates sensing
Faraji, Foad; Heshmat, Haleh; Banava, Sepideh
2017-01-01
EQUIA TM is a new gastrointestinal (GI) system with high compressive strength, surface microhardness (MH), and fluoride release potential. This in vitro study aimed to assess the effect of aging and type of protective coating on the MH of EQUIA TM GI cement. A total of 30 disc-shaped specimens measuring 9 mm in diameter and 2 mm in thickness were fabricated of EQUIA TM GI and divided into three groups of G-Coat nanofilled coating (a), no coating (b) and margin bond (c). The Vickers MH value of specimens was measured before (baseline) and at 3 and 6 months after water storage. Data were analyzed using repeated measures ANOVA. Group B had significantly higher MH than the other two groups at baseline. Both G-Coat and margin bond increased the surface MH of GI at 3 and 6 months. The MH values of G-Coat and margin bond groups did not significantly increase or decrease between 3 and 6 months. The increase in MH was greater in the G-Coat compared to the margin bond group in the long-term. Clinically, margin bond may be a suitable alternative when G-Coat is not available.
Signatures of massive collisions in debris discs. A self-consistent numerical model
NASA Astrophysics Data System (ADS)
Kral, Q.; Thébault, P.; Augereau, J.-C.; Boccaletti, A.; Charnoz, S.
2015-01-01
Context. Violent stochastic collisional events have been invoked as a possible explanation for some debris discs displaying pronounced azimuthal asymmetries or having a luminosity excess exceeding that expected for systems at collisional steady-state. So far, no thorough modelling of the consequences of such stochastic events has been carried out, mainly because of the extreme numerical challenge of coupling the dynamical and collisional evolution of the released dust. Aims: We perform the first fully self-consistent modelling of the aftermath of massive breakups in debris discs. We follow the collisional and dynamical evolution of dust released after the breakup of a Ceres-sized body at 6 AU from its central star. We investigate the duration, magnitude, and spatial structure of the signature left by such a violent event, as well as its observational detectability. Methods: We use the recently developed LIDT-DD code, which handles the coupled collisional and dynamical evolution of debris discs. The main focus is placed on the complex interplay between destructive collisions, Keplerian dynamics, and radiation pressure forces. We use the GRaTer package to estimate the system's luminosity at different wavelengths. Results: The breakup of a Ceres-sized body at 6 AU creates an asymmetric dust disc that is homogenized by the coupled action of collisions and dynamics on a timescale of a few 105 years. After a transient period where it is very steep, the particle size distribution in the system relaxes to a collisional steady-state law after ~104 years. The luminosity excess in the breakup's aftermath should be detectable by mid-IR photometry, from a 30 pc distance, over a period of ~106 years that exceeds the duration of the asymmetric phase of the disc (a few 105 years). As for the asymmetric structures, we derive synthetic images for the VLT/SPHERE and JWST/MIRI instruments, showing that they should be clearly visible and resolved from a 10 pc distance. Images at 1.6 μm (marginally), 11.4, and 15.5 μm show the inner disc structures, while 23 μm images display the outer disc asymmetries.
Cekiç, Osman; Bardak, Yavuz; Tiğ, U Sahin; Yildizoğlu, Uzeyir; Bardak, Handan
2008-04-01
To describe a new method of quantifying the amount of plaque-like hard exudates after intravitreal triamcinolone acetonide injection in diabetic macular edema. This study included 22 eyes of 14 patients (mean age, 63 years) with chronic diabetic macular edema and plaque-like hard exudates. The patients were injected with a single dose of 4 mg intravitreal triamcinolone acetonide. The optic disc size as relative size unit was taken to quantify the hard exudates: Total areas of exudates and the optic nerve head were computed from fundus pictures with a digital analysis program on magnified images. The former was divided by the latter, and the results were expressed as a percentage value. The ratio was used to track improvements in a given eye over 6 months. Average ratio of hard exudates to optic nerve head area reduced to 81% of its initial value at 1 month (P=0.007), to 54% at 3 months (P<0.001) and to 41% at 6 months (P<0.001). The new method allowed detection of a significant reduction of ratio of hard exudates to optic disc area of diabetic plaque-like hard exudates following 4 mg intravitreal triamcinolone.
Optic disc detection using ant colony optimization
NASA Astrophysics Data System (ADS)
Dias, Marcy A.; Monteiro, Fernando C.
2012-09-01
The retinal fundus images are used in the treatment and diagnosis of several eye diseases, such as diabetic retinopathy and glaucoma. This paper proposes a new method to detect the optic disc (OD) automatically, due to the fact that the knowledge of the OD location is essential to the automatic analysis of retinal images. Ant Colony Optimization (ACO) is an optimization algorithm inspired by the foraging behaviour of some ant species that has been applied in image processing for edge detection. Recently, the ACO was used in fundus images to detect edges, and therefore, to segment the OD and other anatomical retinal structures. We present an algorithm for the detection of OD in the retina which takes advantage of the Gabor wavelet transform, entropy and ACO algorithm. Forty images of the retina from DRIVE database were used to evaluate the performance of our method.
Unilateral Vision Loss after a Dental Visit
Khattab, Mohammed H.; Wiegand, Annette; Storch, Marcus; Hoerauf, Hans; Feltgen, Nicolas
2018-01-01
Intraoral local anesthetics are widely used for performing painless dental treatments; however, in some cases, they may cause ocular complications such as meiosis, diplopia, nystagmus, ophthalmoplegia, ptosis, and amaurosis. Mostly, the symptoms disappear after several hours; rarely, they have a prolonged character. We describe the case of a 38-year-old young man who had reduced vision in the left eye 5 days after having received intraoral local anesthesia. A diagnosis of cilioretinal artery occlusion with optic disc swelling was made. Ten weeks later, the patient's visual acuity had increased to 20/20, and the swelling of the optic disc had subsided. Although various possible mechanisms for ocular complications after intraoral local anesthetic administration were suggested in the literature, the exact etiology remains unclear. In this case, inadvertent intravascular injection is believed to be the cause. PMID:29681838
Automatic optic disc segmentation based on image brightness and contrast
NASA Astrophysics Data System (ADS)
Lu, Shijian; Liu, Jiang; Lim, Joo Hwee; Zhang, Zhuo; Tan, Ngan Meng; Wong, Wing Kee; Li, Huiqi; Wong, Tien Yin
2010-03-01
Untreated glaucoma leads to permanent damage of the optic nerve and resultant visual field loss, which can progress to blindness. As glaucoma often produces additional pathological cupping of the optic disc (OD), cupdisc- ratio is one measure that is widely used for glaucoma diagnosis. This paper presents an OD localization method that automatically segments the OD and so can be applied for the cup-disc-ratio based glaucoma diagnosis. The proposed OD segmentation method is based on the observations that the OD is normally much brighter and at the same time have a smoother texture characteristics compared with other regions within retinal images. Given a retinal image we first capture the ODs smooth texture characteristic by a contrast image that is constructed based on the local maximum and minimum pixel lightness within a small neighborhood window. The centre of the OD can then be determined according to the density of the candidate OD pixels that are detected by retinal image pixels of the lowest contrast. After that, an OD region is approximately determined by a pair of morphological operations and the OD boundary is finally determined by an ellipse that is fitted by the convex hull of the detected OD region. Experiments over 71 retinal images of different qualities show that the OD region overlapping reaches up to 90.37% according to the OD boundary ellipses determined by our proposed method and the one manually plotted by an ophthalmologist.
Opportunistic detection of glaucomatous optic discs within a diabetic retinopathy screening service.
Treacy, Maxwell P; O'Neill, Evelyn C; Murphy, Melissa; O'Toole, Louise; Delaney, Yvonne; O'Brien, Colm; Connell, Paul P
2016-06-10
To determine the prevalence of glaucoma among patients referred to a glaucoma service with suspicious disc photographs from the diabetic retinopathy (DR) screening program. A clinical audit of all patients attending a single-center DR screening program in the Mater Misericordiae University Hospital, Dublin, between July 2010 and October 2011 was conducted with a minimum follow-up of 30 months. The DR screening service uses trained technician graders to assess 2-field color retinal photographs for the features of DR. Recently, the service was enhanced so that optic discs are also assessed for signs of glaucoma. In the 16-month study period, 3,697 diabetic patients were photographed. Following photograph grading, 91 (2.46%) were judged to require referral for assessment at the glaucoma clinic. Of these, 63 (69.23%) presented for assessment. Thirteen patients (20.63%) were diagnosed with glaucoma, comprising 7 cases of low-tension glaucoma and 6 cases of primary open-angle glaucoma. Thirty-six patients (57.14%) were classified as glaucoma suspects and 14 patients (22.22%) were discharged back to the DR screening program following normal ocular examination. Only 6 (9.52%) of the 63 patients examined had an intraocular pressure greater than 21 mm Hg. The assessment of DR screening photographs for signs of glaucomatous optic nerve damage should be considered as part of a strategy to improve glaucoma case detection and to reduce the burden of this disease on society.
Jadhav, Vivek Dattatray; Motwani, Bhagwan K; Shinde, Jitendra; Adhapure, Prasad
2017-01-01
The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. The results of the t -test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness.
A unified model for galactic discs: star formation, turbulence driving, and mass transport
NASA Astrophysics Data System (ADS)
Krumholz, Mark R.; Burkhart, Blakesley; Forbes, John C.; Crocker, Roland M.
2018-06-01
We introduce a new model for the structure and evolution of the gas in galactic discs. In the model the gas is in vertical pressure and energy balance. Star formation feedback injects energy and momentum, and non-axisymmetric torques prevent the gas from becoming more than marginally gravitationally unstable. From these assumptions we derive the relationship between galaxies' bulk properties (gas surface density, stellar content, and rotation curve) and their star formation rates, gas velocity dispersions, and rates of radial inflow. We show that the turbulence in discs can be powered primarily by star formation feedback, radial transport, or a combination of the two. In contrast to models that omit either radial transport or star formation feedback, the predictions of this model yield excellent agreement with a wide range of observations, including the star formation law measured in both spatially resolved and unresolved data, the correlation between galaxies' star formation rates and velocity dispersions, and observed rates of radial inflow. The agreement holds across a wide range of galaxy mass and type, from local dwarfs to extreme starbursts to high-redshift discs. We apply the model to galaxies on the star-forming main sequence, and show that it predicts a transition from mostly gravity-driven turbulence at high redshift to star-formation-driven turbulence at low redshift. This transition and the changes in mass transport rates that it produces naturally explain why galaxy bulges tend to form at high redshift and discs at lower redshift, and why galaxies tend to quench inside-out.
NASA Astrophysics Data System (ADS)
Wienkers, A. F.; Ogilvie, G. I.
2018-07-01
Non-linear evolution of the parametric instability of inertial waves inherent to eccentric discs is studied by way of a new local numerical model. Mode coupling of tidal deformation with the disc eccentricity is known to produce exponentially growing eccentricities at certain mean-motion resonances. However, the details of an efficient saturation mechanism balancing this growth still are not fully understood. This paper develops a local numerical model for an eccentric quasi-axisymmetric shearing box which generalizes the often-used Cartesian shearing box model. The numerical method is an overall second-order well-balanced finite volume method which maintains the stratified and oscillatory steady-state solution by construction. This implementation is employed to study the non-linear outcome of the parametric instability in eccentric discs with vertical structure. Stratification is found to constrain the perturbation energy near the mid-plane and localize the effective region of inertial wave breaking that sources turbulence. A saturated marginally sonic turbulent state results from the non-linear breaking of inertial waves and is subsequently unstable to large-scale axisymmetric zonal flow structures. This resulting limit-cycle behaviour reduces access to the eccentric energy source and prevents substantial transport of angular momentum radially through the disc. Still, the saturation of this parametric instability of inertial waves is shown to damp eccentricity on a time-scale of a thousand orbital periods. It may thus be a promising mechanism for intermittently regaining balance with the exponential growth of eccentricity from the eccentric Lindblad resonances and may also help explain the occurrence of 'bursty' dynamics such as the superhump phenomenon.
Ophthalmic examination of the captive western lowland gorilla (Gorilla gorilla gorilla).
Liang, David; Alvarado, Thomas P; Oral, Deniz; Vargas, Jose M; Denena, Melissa M; McCulley, James P
2005-09-01
This study examined the captive western lowland gorilla (Gorilla gorilla gorilla) eye as compared and contrasted with the human eye. Bilateral ophthalmic examinations of western lowland gorillas (n = 5) while under general anesthesia were performed opportunistically, including slit-lamp biomicroscopy, dilated fundus examination, cycloplegic retinoscopy, Schiotz tonometry, corneal diameter and thickness measurements, A-scan and B-scan ultrasonography, keratometry, and cultures of the eyelid margins and bulbar conjunctiva. Mean spherical equivalent refractive error by cycloplegic retinoscopy was +1.20 +/- 0.59 diopters. Mean intraocular pressure by Schiotz tonometry was 12.0 +/- 4.3 mm Hg. Mean optic nerve head cup to disc ratio was 0.42 +/- 0.11. Mean horizontal corneal diameter was 13.4 +/- 0.8 mm, and mean vertical cornea diameter was 12.7 +/- 0.8 mm. Mean central corneal thickness by ultrasound pachymetry was 489 +/- 52 microm. Mean axial length of the eye by A-scan was 22.75 +/- 0.71 mm. Mean lens thickness by A-scan was 4.23 +/- 0.34 mm. Mean anterior chamber depth by A-scan was 4.00 +/- 0.26 mm. Mean keratometry reading was 44.38 +/- 1.64 diopters. Eyelid margin and bulbar conjunctival cultures isolated Candida sp. (n = 5), Staphylococcus aureus (n = 4), Staphylococcus epidermidis (n = 3), Staphylococcus saccharolyticus (n = 3), and Micrococcus sp. (n = 3). This study suggests important similarities between western lowland gorilla and human eyes. These similarities may allow diagnostics, techniques, and equipment for human eye surgery, such as those used for cataract extraction and intraocular lens implantation, to be successfully utilized for gorillas.
López-Muñoz, Gerardo A; Estevez, M-Carmen; Peláez-Gutierrez, E Cristina; Homs-Corbera, Antoni; García-Hernandez, M Carmen; Imbaud, J Ignacio; Lechuga, Laura M
2017-10-15
Nanostructure-based plasmonic biosensors have quickly positioned themselves as interesting candidates for the design of portable optical biosensor platforms considering the potential benefits they can offer in integration, miniaturization, multiplexing, and real-time label-free detection. We have developed a simple integrated nanoplasmonic sensor taking advantage of the periodic nanostructured array of commercial Blu-ray discs. Sensors with two gold film thicknesses (50 and 100nm) were fabricated and optically characterized by varying the oblique-angle of the incident light in optical reflectance measurements. Contrary to the use normal light incidence previously reported with other optical discs, we observed an enhancement in sensitivity and a narrowing of the resonant linewidths as the light incidence angle was increased, which could be related to the generation of Fano resonant modes. The new sensors achieve a figure of merit (FOM) up to 35 RIU -1 and a competitive bulk limit of detection (LOD) of 6.3×10 -6 RIU. These values significantly improve previously reported results obtained with normal light incidence reflectance measurements using similar structures. The sensor has been combined with versatile, simple, ease to-fabricate microfluidics. The integrated chip is only 1cm 2 (including a PDMS flow cell with a 50µm height microfluidic channel fabricated with double-sided adhesive tape) and all the optical components are mounted on a 10cm×10cm portable prototype, illustrating its facile miniaturization, integration and potential portability. Finally, to assess the label-free biosensing capability of the new sensor, we have evaluated the presence of specific antibodies against the GTF2b protein, a tumor-associate antigen (TAA) related to colorectal cancer. We have achieved a LOD in the pM order and have assessed the feasibility of directly measuring biological samples such as human serum. Copyright © 2017 Elsevier B.V. All rights reserved.
Mayama, Chihiro; Tsutsumi, Tae; Saito, Hitomi; Asaoka, Ryo; Tomidokoro, Atsuo; Iwase, Aiko; Otani, Shinichiro; Miyata, Kazunori; Araie, Makoto
2014-01-01
This study was performed to first investigate the morphological differences in the optic nerve head between highly myopic non-glaucomatous controls and highly myopic glaucomatous eyes in comparison with the differences between emmetropic non-glaucomatous controls and emmetropic glaucomatous eyes using confocal scanning laser ophthalmoscopy. Further, the ability of the apparatus in glaucoma diagnosis in highly myopic eyes was compared with that in emmetropic eyes. Healthy subjects and age-matched patients with early-stage open-angle glaucoma were divided into two groups: emmetropic eyes (-1.0 to +1.0 diopters) and highly myopic eyes (-12.0 to -5.0 diopters).The participants were comprised of 65 emmetropic normal eyes, 59 emmetropic glaucomatous eyes, 62 highly myopic normal eyes, and 68 highly myopic glaucomatous eyes and eyes with pathologic myopia were carefully excluded. Confocal scanning laser tomographic parameters were compared among all subjects after adjustment for age and disc area. The ROC curves and sensitivity and specificity for glaucoma detection using several clinical methods were then compared between the emmetropic and highly myopic eyes. Rim area, cup/disc area ratio, mean cup depth, and cup shape measure of glaucoma eyes are significantly different from those of normal eyes in both highly myopic eyes and emmetropic eyes. Methodological overestimation of retinal nerve fiber layer cross sectional area due to optic disc tilting was suggested in the highly myopic eyes. The diagnostic performance of glaucoma using several discriminant methods significantly deteriorated in the highly myopic eyes. In the highly myopic glaucomatous eyes, confocal scanning laser tomographic parameters were significantly different from that of non-glaucomatous highly myopic eyes but diagnostic performance of glaucoma was deteriorated than that in emmetropic eyes. These findings demonstrate the utility and limitations of the apparatus in diagnosing glaucoma in highly myopic patients.
Asami, Tetsu; Kaneko, Hiroki; Miyake, Kensaku; Ota, Ichiro; Miyake, Goichiro; Kato, Seiichi; Yasuda, Shunsuke; Iwase, Takeshi; Ito, Yasuki; Terasaki, Hiroko
2016-01-01
Purpose We report a newly developed device to fragment thrombi in retinal vein occlusion. Methods The new instrument consists of a 23-gauge (G) pipe and a 37-G needle with an internal wire. A total of 40 porcine eyes were used; 20 eyes for experiments in the branch retinal vein (BRV group) and 20 eyes for experiments in the central retinal vein (CRV group). We placed 25-G 3-port trocars, and core vitrectomy was performed. Another 23-G scleral incision was performed for insertion of the needle. The needle pierced the retinal vein at a distance of three- to four- or one-disc diameters from the optic disc (BRV or CRV group, respectively), and the internal wire was advanced toward the disc. The success rates of needle piercing and cannulation of the internal wire were recorded in each group. In the CRV group, the cannulation was deemed successful when the tip reached inside the optic disc. Real-time optical coherence tomography imaging also was performed using the Zeiss Rescan 700 device in porcine eyes. Histologic examination of the retinal vessel inserted with the internal wire was performed. Results The success rates of needle piercing into the BRV and CRV were 85% and 95%, respectively. The success rates of cannulation of the internal wire into the BRV and CRV were 85% and 0%, respectively. The process of cannulation was recorded successfully with the Rescan 700. Histologic examination showed no damages to the endothelial cell layer. Conclusions The needle and internal wire intended to be used for recanalization of BRV occlusion were successfully pierced and cannulated into the BRV. Translational Relevance This newly developed device could become a treatment modality for retinal vein occlusion to fragment thrombi that present treatment methods cannot reach and remove directly. PMID:27730009
Gebhard, Harry; Bowles, Robby; Dyke, Jonathan; Saleh, Tatianna; Doty, Stephen; Bonassar, Lawrence; Härtl, Roger
2010-01-01
Study type: Basic science Introduction: Chronic back pain due to degenerative disc disease (DDD) is among the most important medical conditions causing morbidity and significant health care costs. Surgical treatment options include disc replacement or fusion surgery, but are associated with significant short- and long-term risks.1 Biological tissue-engineering of human intervertebral discs (IVD) could offer an important alternative.2 Recent in vitro data from our group have shown successful engineering and growth of ovine intervertebral disc composites with circumferentially aligned collagen fibrils in the annulus fibrosus (AF) (Figure 1).3 Figure 1 Tissue-engineered composite disc a Experimental steps to generate composite tissue-engineered IVDs3 b Example of different AF formulations on collagen alignment in the AF. Second harmonic generation and two-photon excited fluorescence images of seeded collagen gels (for AF) of 1 and 2.5 mg/ml over time. At seeding, cells and collagen were homogenously distributed in the gels. Over time, AF cells elongated and collagen aligned parallel to cells. Less contraction and less alignment is noted after 3 days in the 2.5 mg/mL gel. c Imaging-based creation of a virtual disc model that will serve as template for the engineered disc. Total disc dimensions (AF and NP) were retrieved from micro-computer tomography (CT) (left images), and nucleus pulposus (NP) dimensions alone were retrieved from T2-weighted MRI images (right images). Merging of MRI and micro-CT models revealed a composite disc model (middle image)—Software: Microview, GE Healthcare Inc., Princeton, NJ; and slicOmatic v4.3, TomoVision, Montreal, Canada. d Flow chart describing the process for generating multi-lamellar tissue engineered IVDs. IVDs are produced by allowing cell-seeded collagen layers to contract around a cell-seeded alginate core (NP) over time Objective: The next step is to investigate if biological disc implants survive, integrate, and restore function to the spine in vivo. A model will be developed that allows efficient in vivo testing of tissue-engineered discs of various compositions and characteristics. Methods: Athymic rats were anesthetized and a dorsal approach was chosen to perform a microsurgical discectomy in the rat caudal spine (Fig. 2,Fig. 3). Control group I (n = 6) underwent discectomy only, Control group II (n = 6) underwent discectomy, followed by reimplantation of the autologous disc. Two treatment groups (group III, n = 6, 1 month survival; group IV, n = 6, 6 months survival) received a tissue-engineered composite disc implant. The rodents were followed clinically for signs of infection, pain level and wound healing. X-rays and magnetic resonance imaging (MRI) were assessed postoperatively and up to 6 months after surgery (Fig. 6,Fig. 7). A 7 Tesla MRI (Bruker) was implemented for assessment of the operated level as well as the adjacent disc (hydration). T2-weighted sequences were interpreted by a semiquantitative score (0 = no signal, 1 = weak signal, 2 = strong signal and anatomical features of a normal disc). Histology was performed with staining for proteoglycans (Alcian blue) and collagen (Picrosirius red) (Fig. 4,Fig. 5). Figure 2 Disc replacement surgery a Operative situs with native disc that has been disassociated from both adjacent vertebrae b Native disc (left) and tissue-engineered implant (right) c Implant in situ before wound closureAF: Annulus fi brosus, nP: nucleus pulposus, eP: endplate, M: Muscle, T: Tendon, s: skin, art: artery, GP: Growth plate, B: Bone Figure 3 Disc replacement surgery. Anatomy of the rat caudal disc space a Pircrosirius red stained axial cut of native disc space b Saffranin-O stained sagittal cut of native disc space Figure 4 Histologies of three separate motion segments from three different rats. Animal one = native IVD, Animal two = status after discectomy, Animal three = tissue-engineered implant (1 month) a–c H&E (overall tissue staining for light micrsocopy) d–f Alcian blue (proteoglycans) g–i Picrosirius red (collagen I and II) Figure 5 Histology from one motion segment four months after implantation of a bio-engineered disc construct a Picrosirius red staining (collagen) b Polarized light microscopy showing collagen staining and collagen organization in AF region c Increased Safranin-O staining (proteoglycans) in NP region of the disc implant d Higher magnification of figure 5c: Integration between implanted tissue-engineered total disc replacement and vertebral body bone Figure 6 MRI a Disc space height measurements in flash/T1 sequence (top: implant (714.0 micrometer), bottom: native disc (823.5 micrometer) b T2 sequence, red circle surrounding the implant NP Figure 7 7 Tesla MRI imaging of rat tail IVDs showing axial images (preliminary pilot data) a Diffusion tensor imaging (DTI) on two explanted rat tail discs in Formalin b Higher magnification of a, showing directional alignment of collagen fibers (red and green) when compared to the color ball on top which maps fibers' directional alignment (eg, fibers directing from left to right: red, from top to bottom: blue) c Native IVD in vivo (successful imaging of top and bottom of the IVD (red) d Gradient echo sequence (GE) showing differentiation between NP (light grey) and AF (dark margin) e GE of reimplanted tail IVD at the explantation level f T1Rho sequence demonstrating the NP (grey) within the AF (dark margin), containing the yellow marked region of interest for value acquisition (preliminary data are consistent with values reported in the literature). g T2 image of native IVD in vivo for monitoring of hydration (white: NP) Results: The model allowed reproducible and complete discectomies as well as disc implantation in the rat tail spine without any surgical or postoperative complications. Discectomy resulted in immediate collapse of the disc space. Preliminary results indicate that disc space height was maintained after disc implantation in groups II, III and IV over time. MRI revealed high resolution images of normal intervertebral discs in vivo. Eight out of twelve animals (groups III and IV) showed a positive signal in T2-weighted images after 1 month (grade 0 = 4, grade 1 = 4, grade 2 = 4). Positive staining was seen for collagen as well as proteoglycans at the site of disc implantation after 1 month in each of the six animals with engineered implants (group III). Analysis of group IV showed positive T2 signal in five out of six animals and disc-height preservation in all animals after 6 months. Conclusions: This study demonstrates for the first time that tissue-engineered composite IVDs with circumferentially aligned collagen fibrils survive and integrate with surrounding vertebral bodies when placed in the rat spine for up to 6 months. Tissue-engineered composite IVDs restored function to the rat spine as indicated by maintenance of disc height and vertebral alignment. A significant finding was that maintenance of the composite structure in group III was observed, with increased proteoglycan staining in the nucleus pulposus region (Figure 4d–f). Proteoglycan and collagen matrix as well as disc height preservation and positive T2 signals in MRI are promising parameters and indicate functionality of the implants. PMID:23637671
Gebhard, Harry; Bowles, Robby; Dyke, Jonathan; Saleh, Tatianna; Doty, Stephen; Bonassar, Lawrence; Härtl, Roger
2010-08-01
Basic science Introduction: Chronic back pain due to degenerative disc disease (DDD) is among the most important medical conditions causing morbidity and significant health care costs. Surgical treatment options include disc replacement or fusion surgery, but are associated with significant short- and long-term risks.1 Biological tissue-engineering of human intervertebral discs (IVD) could offer an important alternative.2 Recent in vitro data from our group have shown successful engineering and growth of ovine intervertebral disc composites with circumferentially aligned collagen fibrils in the annulus fibrosus (AF) (Figure 1).3 Figure 1 Tissue-engineered composite disc a Experimental steps to generate composite tissue-engineered IVDs3b Example of different AF formulations on collagen alignment in the AF. Second harmonic generation and two-photon excited fluorescence images of seeded collagen gels (for AF) of 1 and 2.5 mg/ml over time. At seeding, cells and collagen were homogenously distributed in the gels. Over time, AF cells elongated and collagen aligned parallel to cells. Less contraction and less alignment is noted after 3 days in the 2.5 mg/mL gel. c Imaging-based creation of a virtual disc model that will serve as template for the engineered disc. Total disc dimensions (AF and NP) were retrieved from micro-computer tomography (CT) (left images), and nucleus pulposus (NP) dimensions alone were retrieved from T2-weighted MRI images (right images). Merging of MRI and micro-CT models revealed a composite disc model (middle image)-Software: Microview, GE Healthcare Inc., Princeton, NJ; and slicOmatic v4.3, TomoVision, Montreal, Canada. d Flow chart describing the process for generating multi-lamellar tissue engineered IVDs. IVDs are produced by allowing cell-seeded collagen layers to contract around a cell-seeded alginate core (NP) over time Objective: The next step is to investigate if biological disc implants survive, integrate, and restore function to the spine in vivo. A model will be developed that allows efficient in vivo testing of tissue-engineered discs of various compositions and characteristics. Athymic rats were anesthetized and a dorsal approach was chosen to perform a microsurgical discectomy in the rat caudal spine (Fig. 2,Fig. 3). Control group I (n = 6) underwent discectomy only, Control group II (n = 6) underwent discectomy, followed by reimplantation of the autologous disc. Two treatment groups (group III, n = 6, 1 month survival; group IV, n = 6, 6 months survival) received a tissue-engineered composite disc implant. The rodents were followed clinically for signs of infection, pain level and wound healing. X-rays and magnetic resonance imaging (MRI) were assessed postoperatively and up to 6 months after surgery (Fig. 6,Fig. 7). A 7 Tesla MRI (Bruker) was implemented for assessment of the operated level as well as the adjacent disc (hydration). T2-weighted sequences were interpreted by a semiquantitative score (0 = no signal, 1 = weak signal, 2 = strong signal and anatomical features of a normal disc). Histology was performed with staining for proteoglycans (Alcian blue) and collagen (Picrosirius red) (Fig. 4,Fig. 5). Figure 2 Disc replacement surgery a Operative situs with native disc that has been disassociated from both adjacent vertebrae b Native disc (left) and tissue-engineered implant (right) c Implant in situ before wound closureAF: Annulus fi brosus, nP: nucleus pulposus, eP: endplate, M: Muscle, T: Tendon, s: skin, art: artery, GP: Growth plate, B: BoneFigure 3 Disc replacement surgery. Anatomy of the rat caudal disc space a Pircrosirius red stained axial cut of native disc space b Saffranin-O stained sagittal cut of native disc spaceFigure 4 Histologies of three separate motion segments from three different rats. Animal one = native IVD, Animal two = status after discectomy, Animal three = tissue-engineered implant (1 month) a-c H&E (overall tissue staining for light micrsocopy) d-f Alcian blue (proteoglycans) g-i Picrosirius red (collagen I and II)Figure 5 Histology from one motion segment four months after implantation of a bio-engineered disc construct a Picrosirius red staining (collagen) b Polarized light microscopy showing collagen staining and collagen organization in AF region c Increased Safranin-O staining (proteoglycans) in NP region of the disc implant d Higher magnification of figure 5c: Integration between implanted tissue-engineered total disc replacement and vertebral body boneFigure 6 MRI a Disc space height measurements in flash/T1 sequence (top: implant (714.0 micrometer), bottom: native disc (823.5 micrometer) b T2 sequence, red circle surrounding the implant NPFigure 7 7 Tesla MRI imaging of rat tail IVDs showing axial images (preliminary pilot data) a Diffusion tensor imaging (DTI) on two explanted rat tail discs in Formalin b Higher magnification of a, showing directional alignment of collagen fibers (red and green) when compared to the color ball on top which maps fibers' directional alignment (eg, fibers directing from left to right: red, from top to bottom: blue) c Native IVD in vivo (successful imaging of top and bottom of the IVD (red) d Gradient echo sequence (GE) showing differentiation between NP (light grey) and AF (dark margin) e GE of reimplanted tail IVD at the explantation level f T1Rho sequence demonstrating the NP (grey) within the AF (dark margin), containing the yellow marked region of interest for value acquisition (preliminary data are consistent with values reported in the literature). g T2 image of native IVD in vivo for monitoring of hydration (white: NP) Results: The model allowed reproducible and complete discectomies as well as disc implantation in the rat tail spine without any surgical or postoperative complications. Discectomy resulted in immediate collapse of the disc space. Preliminary results indicate that disc space height was maintained after disc implantation in groups II, III and IV over time. MRI revealed high resolution images of normal intervertebral discs in vivo. Eight out of twelve animals (groups III and IV) showed a positive signal in T2-weighted images after 1 month (grade 0 = 4, grade 1 = 4, grade 2 = 4). Positive staining was seen for collagen as well as proteoglycans at the site of disc implantation after 1 month in each of the six animals with engineered implants (group III). Analysis of group IV showed positive T2 signal in five out of six animals and disc-height preservation in all animals after 6 months. This study demonstrates for the first time that tissue-engineered composite IVDs with circumferentially aligned collagen fibrils survive and integrate with surrounding vertebral bodies when placed in the rat spine for up to 6 months. Tissue-engineered composite IVDs restored function to the rat spine as indicated by maintenance of disc height and vertebral alignment. A significant finding was that maintenance of the composite structure in group III was observed, with increased proteoglycan staining in the nucleus pulposus region (Figure 4d-f). Proteoglycan and collagen matrix as well as disc height preservation and positive T2 signals in MRI are promising parameters and indicate functionality of the implants.
The origin of the structure of large-scale magnetic fields in disc galaxies
NASA Astrophysics Data System (ADS)
Nixon, C. J.; Hands, T. O.; King, A. R.; Pringle, J. E.
2018-07-01
The large-scale magnetic fields observed in spiral disc galaxies are often thought to result from dynamo action in the disc plane. However, the increasing importance of Faraday depolarization along any line of sight towards the galactic plane suggests that the strongest polarization signal may come from well above (˜0.3-1 kpc) this plane, from the vicinity of the warm interstellar medium (WIM)/halo interface. We propose (see also Henriksen & Irwin 2016) that the observed spiral fields (polarization patterns) result from the action of vertical shear on an initially poloidal field. We show that this simple model accounts for the main observed properties of large-scale fields. We speculate as to how current models of optical spiral structure may generate the observed arm/interarm spiral polarization patterns.
Kitaoka, Yasushi; Tanito, Masaki; Yokoyama, Yu; Nitta, Koji; Katai, Maki; Omodaka, Kazuko; Nakazawa, Toru
2018-01-01
The Glaucoma Stereo Analysis Study, a cross-sectional multicenter collaborative study, used a stereo fundus camera (nonmyd WX) to assess various morphological parameters of the optic nerve head (ONH) in glaucoma patients. We compared the associations of each parameter between the visual field loss progression group and no-progression group. The study included 187 eyes of 187 patients with primary open-angle glaucoma or normal-tension glaucoma. We divided the mean deviation (MD) slope values of all patients into the progression group (<-0.3 dB/year) and no-progression group (≧-0.3 dB/year). ONH morphological parameters were calculated with prototype analysis software. The correlations between glaucomatous visual field progression and patient characteristics or each ONH parameter were analyzed with Spearman's rank correlation coefficient. The MD slope averages in the progression group and no-progression group were -0.58 ± 0.28 dB/year and 0.05 ± 0.26 dB/year, respectively. Among disc parameters, vertical disc width (diameter), disc area, cup area, and cup volume in the progression group were significantly less than those in the no-progression group. Logistic regression analysis revealed a significant association between the visual field progression and disc area (odds ratio 0.49/mm 2 disc area). A smaller disc area may be associated with more rapid glaucomatous visual field progression.
Appearance of Keplerian discs orbiting Kerr superspinars
NASA Astrophysics Data System (ADS)
Stuchlík, Zdeněk; Schee, Jan
2010-11-01
We study optical phenomena related to the appearance of Keplerian accretion discs orbiting Kerr superspinars predicted by string theory. The superspinar exterior is described by standard Kerr naked singularity geometry breaking the black hole limit on the internal angular momentum (spin). We construct local photon escape cones for a variety of orbiting sources that enable us to determine the superspinars silhouette in the case of distant observers. We show that the superspinar silhouette depends strongly on the assumed edge where the external Kerr spacetime is joined to the internal spacetime governed by string theory and significantly differs from the black hole silhouette. The appearance of the accretion disc is strongly dependent on the value of the superspinar spin in both their shape and frequency shift profile. Apparent extension of the disc grows significantly with the growing spin, while the frequency shift grows with the descending spin. This behaviour differs substantially from the appearance of discs orbiting black holes enabling thus, at least in principle, to distinguish clearly the Kerr superspinars and black holes. In vicinity of a Kerr superspinar the non-escaped photons have to be separated to those captured by the superspinar and those being trapped in its strong gravitational field leading to self-illumination of the disc that could even influence its structure and cause self-reflection effect of radiation of the disc. The amount of trapped photons grows with descending superspinar spin. We thus can expect significant self-illumination effects in the field of Kerr superspinars with near-extreme spin a ~ 1.
Mapping the accretion disc of the short period eclipsing binary SDSS J0926+3624
NASA Astrophysics Data System (ADS)
Schlindwein, Wagner; Baptista, Raymundo
2018-05-01
We report the analysis of time-series of optical photometry of SDSS J0926+3624 collected with the Liverpool Robotic Telescope between 2012 February and March while the object was in quiescence. We combined our median eclipse timing with those in the literature to revise the ephemeris and confirm that the binary period is increasing at a rate \\dot{P}=(3.2 ± 0.4)× 10^{-13} s/s. The light curves show no evidence of either the orbital hump produced by a bright spot at disc rim or of superhumps; the average out-of-eclipse brightness level is consistently lower than previously reported. The eclipse map from the average light curve shows a hot white dwarf surrounded by a faint, cool accretion disc plus enhanced emission along the gas stream trajectory beyond the impact point at the outer disc rim, suggesting the occurrence of gas stream overflow/penetration at that epoch. We estimate a disc mass input rate of \\dot{M}=(9 ± 1)× 10^{-12} M_⊙ yr^{-1}, more than an order of magnitude lower than that expected from binary evolution with conservative mass transfer.
Ho, Joyce K.; Stanford, Madison P.; Shariati, Mohammad A.; Dalal, Roopa; Liao, Yaping Joyce
2013-01-01
Purpose. The optic nerve is part of the central nervous system, and interruption of this pathway due to ischemia typically results in optic atrophy and loss of retinal ganglion cells. In this study, we assessed in vivo retinal changes following murine anterior ischemic optic neuropathy (AION) by using spectral-domain optical coherence tomography (SD-OCT) and compared these anatomic measurements to that of histology. Methods. We induced ischemia at the optic disc via laser-activated photochemical thrombosis, performed serial SD-OCT and manual segmentation of the retinal layers to measure the ganglion cell complex (GCC) and total retinal thickness, and correlated these measurements with that of histology. Results. There was impaired perfusion and leakage at the optic disc on fluorescein angiography immediately after AION and severe swelling and distortion of the peripapillary retina on day-1. We used SD-OCT to quantify the changes in retinal thickness following experimental AION, which revealed significant thickening of the GCC on day-1 after ischemia followed by gradual thinning that plateaued by week-3. Thickness of the peripapillary sensory retina was also increased on day-1 and thinned chronically. This pattern of acute retinal swelling and chronic thinning on SD-OCT correlated well with changes seen in histology and corresponded to loss of retinal ganglion layer cells after ischemia. Conclusions. This was a serial SD-OCT quantification of acute and chronic changes following experimental AION, which revealed changes in the GCC similar to that of human AION, but over a time frame of weeks rather than months. PMID:23887804
Outer edges of debris discs. How sharp is sharp?
NASA Astrophysics Data System (ADS)
Thébault, P.; Wu, Y.
2008-04-01
Context: Rings or annulus-like features have been observed in most imaged debris discs. Outside the main ring, while some systems (e.g., β Pictoris and AU Mic) exhibit smooth surface brightness profiles (SB) that fall off roughly as ~r-3.5, others (e.g. HR 4796A and HD 139664) display large drops in luminosity at the ring's outer edge and steeper radial luminosity profiles. Aims: We seek to understand this diversity of outer edge profiles under the “natural” collisional evolution of the system, without invoking external agents such as planets or gas. Methods: We use a multi-annulus statistical code to follow the evolution of a collisional population, ranging in size from dust grains to planetesimals and initially confined within a belt (the “birth ring”). The crucial effect of radiation pressure on the dynamics and spatial distribution of the smallest grains is taken into account. We explore the dependence of the resulting disc surface brightness profile on various parameters. Results: The disc typically evolves toward a “standard” steady state, where the radial surface brightness profile smoothly decreases with radius as r-3.5 outside the birth ring. This confirms and extends the semi-analytical study of Strubbe & Chiang (2006, ApJ, 648, 652) and provides a firm basis for interpreting observed discs. Deviations from this typical profile, in the form of a sharp outer edge and a steeper fall-off, occur for two “extreme” cases: 1) when the birth ring is so massive that it becomes radially optically thick for the smallest grains. However, the required disc mass is probably too high here to be realistic; 2) when the dynamical excitation of the dust-producing planetesimals is so low (< e> and < i> ≤ 0.01) that the smallest grains, which otherwise dominate the optical depth of the system, are preferentially depleted. This low-excitation case, although possibly not generic, cannot be ruled out by observations for most systems, . Conclusions: Our “standard” profile provides a satisfactory explanation for a large group of debris discs that show smooth outer edges and SB ∝ r-3.5. Systems with sharper outer edges, barring other confining agents, could still be explained by “natural” collisional evolution if their dynamical excitation is very low. We show that such a dynamically-cold case provides a satisfactory fit to the specific HR4796A ring.
A disc inside the bipolar planetary nebula M2-9
NASA Astrophysics Data System (ADS)
Lykou, F.; Chesneau, O.; Zijlstra, A. A.; Castro-Carrizo, A.; Lagadec, E.; Balick, B.; Smith, N.
2011-03-01
Aims: Bipolarity in proto-planetary and planetary nebulae is associated with events occurring in or around their cores. Past infrared observations have revealed the presence of dusty structures around the cores, many in the form of discs. Characterising those dusty discs provides invaluable constraints on the physical processes that govern the final mass expulsion of intermediate mass stars. We focus this study on the famous M2-9 bipolar nebula, where the moving lighthouse beam pattern indicates the presence of a wide binary. The compact and dense dusty core in the centre of the nebula can be studied by means of optical interferometry. Methods: M2-9 was observed with VLTI/MIDI at 39-47 m baselines with the UT2-UT3 and UT3-UT4 baseline configurations. These observations are interpreted using a dust radiative transfer Monte Carlo code. Results: A disc-like structure is detected perpendicular to the lobes, and a good fit is found with a stratified disc model composed of amorphous silicates. The disc is compact, 25 × 35 mas at 8 μm and 37 × 46 mas at 13 μm. For the adopted distance of 1.2 kpc, the inner rim of the disc is ~15 AU. The mass represents a few percent of the mass found in the lobes. The compactness of the disc puts strong constraints on the binary content of the system, given an estimated orbital period 90-120 yr. We derive masses of the binary components between 0.6-1.0 M⊙ for a white dwarf and 0.6-1.4 M⊙ for an evolved star. We present different scenarios on the geometric structure of the disc accounting for the interactions of the binary system, which includes an accretion disc as well. Based on observations collected at the European Organisation for Astronomical Research in the Southern Hemisphere, Chile, ESO N: 079.D-146.
Visual Impairment and Intracranial Hypertension: An Emerging Spaceflight Risk
NASA Technical Reports Server (NTRS)
Fogarty, Jennifer A.; Polk, J. D.; Tarver, W.; Gibson, C. R.; Sargsyan, A.; Taddeo, T.; Alexander, D.; Otto, C.
2010-01-01
What is the risk? Given that astronauts exposed to microgravity experience a cephalad fluid shift, and that both symptomatic and asymptomatic astronauts have exhibited optic nerve sheath edema on MRI, there is a high probability that all astronauts have some degree of increased intracranial pressure (ICP; intracranial hypertension), and that those susceptible (via eye architecture, anatomy, narrow optic disc) have a high likelihood of developing papilledema (optic disc edema, globe flattening), choroidal folds, and/or hyperopic shifts and that the degree of edema may determine long-term or permanent vision impairment or loss. Back to back panels on this topic have been developed to address this emerging risk. The first panel will focus on the 6 clinical cases with emphasis on ophthalmic findings and imaging techniques used pre-, in-, and post-flight. The second panel will discuss the operational mitigation and medical requirements, the potential role of CO2 on ISS, and the research approach being developed. In total these back to back panels will explore what is known about this risk, what has been done immediately to address it, and how an integrated research model is being developed.
ALMA observations of the multiplanet system 61 Vir: what lies outside super-Earth systems?
NASA Astrophysics Data System (ADS)
Marino, S.; Wyatt, M. C.; Kennedy, G. M.; Holland, W.; Matrà, L.; Shannon, A.; Ivison, R. J.
2017-08-01
A decade of surveys has hinted at a possible higher occurrence rate of debris discs in systems hosting low-mass planets. This could be due to common favourable forming conditions for rocky planets close in and planetesimals at large radii. In this paper, we present the first resolved millimetre study of the debris disc in the 4.6 Gyr old multiplanet system 61 Vir, combining Atacama Large Millimeter/submillimeter Array and James Clerk Maxwell Telescope data at 0.86 mm. We fit the data using a parametric disc model, finding that the disc of planetesimals extends from 30 au to at least 150 au, with a surface density distribution of millimetre-sized grains with a power-law slope of 0.1^{+1.1}_{-0.8}. We also present a numerical collisional model that can predict the evolution of the surface density of millimetre grains for a given primordial disc, finding that it does not necessarily have the same radial profile as the total mass surface density (as previous studies suggested for the optical depth), with the former being flatter. Finally, we find that if the planetesimal disc was stirred at 150 au by an additional unseen planet, that planet should be more massive than 10 M⊕ and lie between 10 and 20 au. Lower planet masses and semimajor axes down to 4 au are possible for eccentricities ≫0.1.
Optical assessment of tumor resection margins in the breast
Brown, J. Quincy; Bydlon, Torre M.; Richards, Lisa M.; Yu, Bing; Kennedy, Stephanie A.; Geradts, Joseph; Wilke, Lee G.; Junker, Marlee; Gallagher, Jennifer; Barry, William; Ramanujam, Nimmi
2011-01-01
Breast conserving surgery, in which the breast tumor and surrounding normal tissue are removed, is the primary mode of treatment for invasive and in situ carcinomas of the breast, conditions that affect nearly 200,000 women annually. Of these nearly 200,000 patients who undergo this surgical procedure, between 20–70% of them may undergo additional surgeries to remove tumor that was left behind in the first surgery, due to the lack of intra-operative tools which can detect whether the boundaries of the excised specimens are free from residual cancer. Optical techniques have many attractive attributes which may make them useful tools for intra-operative assessment of breast tumor resection margins. In this manuscript, we discuss clinical design criteria for intra-operative breast tumor margin assessment, and review optical techniques appied to this problem. In addition, we report on the development and clinical testing of quantitative diffuse reflectance imaging (Q-DRI) as a potential solution to this clinical need. Q-DRI is a spectral imaging tool which has been applied to 56 resection margins in 48 patients at Duke University Medical Center. Clear sources of contrast between cancerous and cancer-free resection margins were identified with the device, and resulted in an overall accuracy of 75% in detecting positive margins. PMID:21544237
Klatt, K; Schmidt, E; Scheuerle, A F
2008-04-01
The Ocular Hypertension Treatment Study (OHTS) has shown that analyzing changes of the optic disc configuration is superior to evaluating visual field findings for the early detection of primary open angle glaucoma. The Confocal Scanning Laser Ophthalmoscopy Ancillary Study (CSLO) is the first study to reveal that certain topographic baseline measurements of the optic disc are significantly associated with the development of primary open angle glaucoma in patients with ocular hypertension. An abnormally increased "mean height contour" value proved to be the individual parameter connected with the highest risk. The reliability of the Moorfields Regression Analysis of certain individual sectors during early detection of a primary angle glaucoma is higher than that of the global measurement. The temporal superior and inferior as well as the nasal inferior sectors have the highest positive predictive values and the largest risks in both univariate and multivariate analysis.
Wax, M B; Ridley, M E; Magargal, L E
1982-07-01
A 14-year-old black boy with sickle cell trait, who sustained a traumatic hyphema, developed moderately elevated intraocular pressure that failed to respond to carbonic anhydrase inhibitors and osmotic agents. On the tenth postinjury day, a sudden increased cupping of the optic disc and partial central retinal artery obstruction caused painless loss of vision. Reversal of the cupping, the retinal ischemia, and the intraocular pressure was documented following anterior chamber paracentesis, and visual acuity returned to 6/6. Pathophysiology of the posterior ischemia is discussed. This case documents the potentially debilitating course of traumatic hyphema in "benign" sickle cell trait and its avoidance with proper management. The authors endorse recent suggestions for careful observation of any sickle cell patient with traumatic hyphema, and recommend anterior chamber paracentesis, supplemental oxygen, and avoidance of osmotic agents, if secondary glaucoma develops following the initial trauma.
Analysis of observations of the dwarf nova pegasi 2010
NASA Astrophysics Data System (ADS)
Shimansky, V. V.; Mitrofanova, A. A.; Borisov, N. V.; Gabdeev, M. M.
2013-06-01
Analysis of photometric and spectroscopic observations of GSC 02197-00886 at the outburst maximum (on May 8, 2010) and at the stage of relaxation towards the quiescent (on August 4, 2010) was performed. Radiation of an optically thick accretion disc with a hot boundary layer dominates the spectra, which are consistent with the spectra of a WZ Sge-type dwarf novae. In the relaxation phase, an optically thin accretion disc with radiation in the HI and HeI emission lines is observed against the background of the absorption spectrum of a white dwarf. The parameters of GSC 02197-00886, which were determined by combining the radial velocities of the components with the assumption that the secondary component is close to mainsequence stars, differ significantly from the parameters that characterize other WZ Sge-type systems. We hypothesize that the secondary component was excited in the course of the outburst and experienced long-lasting relaxation towards the main-sequence state.
NASA Astrophysics Data System (ADS)
Sumi, T.; Wu, X.; Udalski, A.; Szymański, M.; Kubiak, M.; Pietrzyński, G.; Soszyński, I.; Woźniak, P.; Żebruń, K.; Szewczyk, O.; Wyrzykowski, Ł.
2004-03-01
We present a proper-motion (μ) catalogue of 5 080 236 stars in 49 Optical Gravitational Lensing Experiment II (OGLE-II) Galactic bulge (GB) fields, covering a range of -11° < l < 11° and -6° < b < 3°, the total area close to 11 deg2. The proper-motion measurements are based on 138-555 I-band images taken during four observing seasons: 1997-2000. The catalogue stars are in the magnitude range 11 < I < 18 mag. In particular, the catalogue includes red clump giants and red giants in the GB, and main-sequence stars in the Galactic disc. The proper motions up to μ= 500 mas yr-1 were measured with a mean accuracy of 0.8-3.5 mas yr-1, depending on the brightness of a star. This catalogue may be useful for studying the kinematics of stars in the GB and the Galactic disc.
A submillimeter background galaxy projected on the debris disk of HD95086 revealed by ALMA
NASA Astrophysics Data System (ADS)
Zapata, Luis A.; Ho, Paul T. P.; Rodríguez, Luis F.
2018-06-01
We present sensitive observations carried out with the Atacama Large Millimeter/Submillimeter Array (ALMA) of the dusty debris disc HD 95086. These observations were made in bands 6 (223 GHz) and 7 (338 GHz) with an angular resolution of about 1 arcsec, which allowed us to resolve well the debris disc with a deconvolved size of 7.0 × 6.0 arcsec2 and with an inner depression of about 2 arcsec. We do not detect emission from the star itself and the possible inner dusty belt. We also do not detect CO (J = 2-1) and (J = 3-2) emission, excluding the possibility of an evolved gaseous primordial disc as noted in previous studies of HD95086. We estimated a lower limit for the gas mass of ≤0.01 M⊕ for the debris disc of HD95086. From the mm. emission, we computed a dust mass for the debris disc HD95086 of 0.5 ± 0.2 M⊕, resulting in a dust-to-gas ratio of ≥50. Finally, we confirm the detection of a strong submillimeter source to the north-west of the disc (ALMA-SMM1) revealed by recent ALMA observations. This new source might be interpreted as a planet in formation on the periphery of the debris disc HD 95086 or as a strong impact between dwarf planets. However, given the absence of the proper motions of ALMA-SMM1 similar to those reported in the debris disc (estimated from these new ALMA observations) and for the optical star, this is more likely to be a submillimeter background galaxy.
NASA Astrophysics Data System (ADS)
Muramatsu, Chisako; Hatanaka, Yuji; Iwase, Tatsuhiko; Hara, Takeshi; Fujita, Hiroshi
2010-03-01
Abnormalities of retinal vasculatures can indicate health conditions in the body, such as the high blood pressure and diabetes. Providing automatically determined width ratio of arteries and veins (A/V ratio) on retinal fundus images may help physicians in the diagnosis of hypertensive retinopathy, which may cause blindness. The purpose of this study was to detect major retinal vessels and classify them into arteries and veins for the determination of A/V ratio. Images used in this study were obtained from DRIVE database, which consists of 20 cases each for training and testing vessel detection algorithms. Starting with the reference standard of vasculature segmentation provided in the database, major arteries and veins each in the upper and lower temporal regions were manually selected for establishing the gold standard. We applied the black top-hat transformation and double-ring filter to detect retinal blood vessels. From the extracted vessels, large vessels extending from the optic disc to temporal regions were selected as target vessels for calculation of A/V ratio. Image features were extracted from the vessel segments from quarter-disc to one disc diameter from the edge of optic discs. The target segments in the training cases were classified into arteries and veins by using the linear discriminant analysis, and the selected parameters were applied to those in the test cases. Out of 40 pairs, 30 pairs (75%) of arteries and veins in the 20 test cases were correctly classified. The result can be used for the automated calculation of A/V ratio.
Stellar parameters and H α line profile variability of Be stars in the BeSOS survey
NASA Astrophysics Data System (ADS)
Arcos, C.; Kanaan, S.; Chávez, J.; Vanzi, L.; Araya, I.; Curé, M.
2018-03-01
The Be phenomenon is present in about 20 per cent of B-type stars. Be stars show variability on a broad range of time-scales, which in most cases is related to the presence of a circumstellar disc of variable size and structure. For this reason, a time-resolved survey is highly desirable in order to understand the mechanisms of disc formation, which are still poorly understood. In addition, a complete observational sample would improve the statistical significance of the study of stellar and disc parameters. The `Be Stars Observation Survey' (BeSOS) is a survey containing reduced spectra obtained using the Pontifica Universidad Católica High Echelle Resolution Optical Spectrograph (PUCHEROS) with a spectral resolution of 17 000 in the range 4260-7300 Å. BeSOS's main objective is to offer consistent spectroscopic and time-resolved data obtained with one instrument. The user can download or plot the data and obtain stellar parameters directly from the website. We also provide a star-by-star analysis based on photometric, spectroscopic and interferometric data, as well as general information about the whole BeSOS sample. Recently, BeSOS led to the discovery of a new Be star HD 42167 and facilitated study of the V/R variation of HD 35165 and HD 120324, the steady disc of HD 110335 and the Be shell status of HD 127972. Optical spectra used in this work, as well as the stellar parameters derived, are available online at http://besos.ifa.uv.cl.
Optical classification for quality and defect analysis of train brakes
NASA Astrophysics Data System (ADS)
Glock, Stefan; Hausmann, Stefan; Gerke, Sebastian; Warok, Alexander; Spiess, Peter; Witte, Stefan; Lohweg, Volker
2009-06-01
In this paper we present an optical measurement system approach for quality analysis of brakes which are used in high-speed trains. The brakes consist of the so called brake discs and pads. In a deceleration process the discs will be heated up to 500°C. The quality measure is based on the fact that the heated brake discs should not generate hot spots inside the brake material. Instead, the brake disc should be heated homogeneously by the deceleration. Therefore, it makes sense to analyze the number of hot spots and their relative gradients to create a quality measure for train brakes. In this contribution we present a new approach for a quality measurement system which is based on an image analysis and classification of infra-red based heat images. Brake images which are represented in pseudo-color are first transformed in a linear grayscale space by a hue-saturation-intensity (HSI) space. This transform is necessary for the following gradient analysis which is based on gray scale gradient filters. Furthermore, different features based on Haralick's measures are generated from the gray scale and gradient images. A following Fuzzy-Pattern-Classifier is used for the classification of good and bad brakes. It has to be pointed out that the classifier returns a score value for each brake which is between 0 and 100% good quality. This fact guarantees that not only good and bad bakes can be distinguished, but also their quality can be labeled. The results show that all critical thermal patterns of train brakes can be sensed and verified.
Anterior ischemic optic neuropathy after conventional coronary artery bypass graft surgery.
Dorecka, Mariola; Miniewicz-Kurkowska, Joanna; Romaniuk, Dorota; Gajdzik-Gajdecka, Urszula; Wójcik-Niklewska, Bogumiła
2011-06-01
Perioperative optic neuropathy is a disease which can lead to serious, irreversible damage of vision. This complication could be the result of non-ocular surgery, for example, cardiac or spinal procedures. We present a case of anterior ischemic neuropathy (AION) which occurred following a conventional coronary artery bypass graft procedure. A 57-year-old man, 4 days after Conventional Coronary Artery Bypass Graft surgery as result of multi-vessel stabile coronary artery disease and history of anterolateral wall myocardial infarction, was admitted to the Eye Clinic due to significant loss of vision in his right eye. The patient had hypertension and was a heavy smoker. On admission, the slit lamp examination revealed a relative afferent pupillary defect in the right eye. The fundus examination showed optic disc edema with the presence of flame hemorrhages. Best corrected visual acuity (BCVA) was 0.02. The results of eye examination and fluorescein angiography confirmed the diagnosis of AION. Anti-aggregation and antithrombotic treatment was continued with steroids and vasodilators. After 7 days of this treatment we noticed the improvement of BCVA to 0.2. At 6-month follow-up, the vision was stable, and fundus examination revealed optic disc atrophy. After cardiac surgical operations, such as coronary artery bypass graft procedures, anterior ischemic optic neuropathy may occur. In those cases, close cooperation between the various specialists is necessary.
A novel collinear optical system with annulus mirrors for holographic disc driver
NASA Astrophysics Data System (ADS)
Wang, Ye
2008-12-01
This paper focus on a novel collinear lens system with annulus mirrors for holographic disc driver, both information beam and reference beam are use same laser beam. The expanded and parallel laser beam, center part of it as the information beam then through Fourier transform lens, the beam around center part as a reference beam. On this axis, the ring reference beam reflected by two annulus shaped mirrors, then became a convergent beam, together with the information beam which through the first Fourier transform lens then produce holographic pattern to be write into the holographic disc behind of them, this lens system with two mirrors made the angle between information beam and reference beam more wide, can improved the multiplex level of holographic storage. Pair of Fourier transform lens with advance performance is designed in this paper.
Construction of the STAR Event Plane Detector
NASA Astrophysics Data System (ADS)
Adams, Joseph
2017-09-01
The Event Plane Detector (EPD) is an upgrade to the STAR experiment at RHIC, providing high granularity and acceptance in the forward (2.2 < |eta| < 5.1) region. This will improve the resolution of the event plane determination and allow selection on the collision centrality at rapidities well-separated from the midrapidity region measured by the STAR Time Projection Chamber (TPC). The EPD consists of two scintillator discs, one at positive and one at negative rapidity, 3.75 m from the center of the TPC. Each disc is segmented into 372 optically isolated tiles, read out by wavelength shifting fibers coupled to silicon photomultipliers. One quarter of a single disc was installed in STAR for the 2017 run for commissioning. In this talk I will discuss the construction of the EPD, the installation of the quarter wheel, and plans for full installation in 2018.
NASA Astrophysics Data System (ADS)
Jin, Chichuan; Done, Chris; Ward, Martin; Gardner, Emma
2017-10-01
We present a detailed multiwavelength study of an unobscured, highly super-Eddington Type-1 QSO RX J0439.6-5311. We combine the latest XMM-Newton observation with all archival data from infrared to hard X-rays. The optical spectrum is very similar to that of 1H 0707-495 in having extremely weak [O III] and strong Fe II emission lines, although the black hole mass is probably slightly higher at 5-10 × 106 M⊙. The broad-band spectral energy distribution is uniquely well defined due to the extremely low Galactic and intrinsic absorption, so the bolometric luminosity is tightly constrained. The optical/UV accretion disc continuum is seen down to 900 Å, showing that there is a standard thin disc structure down to R ≥ 190-380 Rg and determining the mass accretion rate through the outer disc. This predicts a much higher bolometric luminosity than observed, indicating that there must be strong wind and/or advective energy losses from the inner disc, as expected for a highly super-Eddington accretion flow. Significant outflows are detected in both the narrow-line region (NLR) and broad-line region (BLR) emission lines, confirming the presence of a wind. We propose a global picture for the structure of a super-Eddington accretion flow where the inner disc puffs up, shielding much of the potential NLR material, and show how inclination angle with respect to this and the wind can explain very different X-ray properties of RX J0439.6-5311 and 1H 0707-495. Therefore, this source provides strong supporting evidence that 'simple' and 'complex' super-Eddington NLS1s can be unified within the same accretion flow scenario but with different inclination angles. We also propose that these extreme NLS1s could be the low-redshift analogues of weak emission-line quasars.
Mark-forming simulations of phase-change land/groove disks
NASA Astrophysics Data System (ADS)
Nishi, Yoshiko; Shimano, Takeshi; Kando, Hidehiko
2000-09-01
The track pitches of optical discs have become so narrow that it is comparable to the wavelength of laser beam. Finite-difference time-domain (FDTD) simulation, based on vector diffraction analysis, can predict the propagation of light more accurately than scalar analysis, when the size of media texture becomes sub-micron order. The authors applied FDTD simulation to land-and-groove optical disc models, and found out that the effects of 3D geometry is not negligible in analyzing the energy absorption of light inside the land- and-groove multi-layered media. The electromagnetic field in the media does not have the same intensity distribution as the incident beam. Furthermore, the heat conduction inside the media depends on the disc geometry, so the beam spots centered on land and groove makes different effects in heating the recording layers. That is, the spatial and historical profile of temperature requires 3D analysis for both incident light absorption and heat conduction. The difference in temperature profiles is applied to the phase change simulator to see the writing process of the marks in land and groove. We have integrated three simulators: FDTD analysis, heat conduction and phase change simulation. These simulators enabled to evaluate the differences in mark forming process between land and groove.
Medeiros, Felipe A.; Alencar, Luciana M.; Zangwill, Linda M.; Bowd, Christopher; Vizzeri, Gianmarco; Sample, Pamela A.; Weinreb, Robert N.
2010-01-01
Purpose To evaluate the ability of scanning laser polarimetry with variable corneal compensation to detect progressive retinal nerve fiber layer (RNFL) loss in glaucoma patients and patients suspected of having the disease. Methods This was an observational cohort study that included 335 eyes of 195 patients. Images were obtained annually with the GDx VCC scanning laser polarimeter, along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. The median follow-up time was 3.94 years. Progression was determined using commercial software for SAP and by masked assessment of optic disc stereophotographs performed by expert graders. Random coefficient models were used to evaluate the relationship between RNFL thickness measurements over time and progression as determined by SAP and/or stereophotographs. Results From the 335 eyes, 34 (10%) showed progression over time by stereophotographs and/or SAP. Average GDx VCC measurements decreased significantly over time for both progressors as well as non-progressors. However, the rate of decline was significantly higher in the progressing group (−0.70 μm/year) compared to the non-progressing group (−0.14 μm/year; P = 0.001). Black race and male sex were significantly associated with higher rates of RNFL loss during follow-up. Conclusions The GDx VCC scanning laser polarimeter was able to identify longitudinal RNFL loss in eyes that showed progression in optic disc stereophotographs and/or visual fields. These findings suggest that this technology could be useful to detect and monitor progressive disease in patients with established diagnosis of glaucoma or suspected of having the disease. PMID:19029038
Powerful radiative jets in supercritical accretion discs around non-spinning black holes
NASA Astrophysics Data System (ADS)
Sądowski, Aleksander; Narayan, Ramesh
2015-11-01
We describe a set of simulations of supercritical accretion on to a non-rotating supermassive black hole (BH). The accretion flow takes the form of a geometrically thick disc with twin low-density funnels around the rotation axis. For accretion rates {gtrsim } 10 dot{M}_Edd, there is sufficient gas in the funnel to make this region optically thick. Radiation from the disc first flows into the funnel, after which it accelerates the optically thick funnel gas along the axis. The resulting jet is baryon loaded and has a terminal density-weighted velocity ≈0.3c. Much of the radiative luminosity is converted into kinetic energy by the time the escaping gas becomes optically thin. These jets are not powered by BHrotation or magnetic driving, but purely by radiation. Their characteristic beaming angle is ˜0.2 rad. For an observer viewing down the axis, the isotropic equivalent luminosity of total energy is as much as 1048 erg s- 1 for a 107 M⊙ BH accreting at 103 Eddington. Therefore, energetically, the simulated jets are consistent with observations of the most powerful tidal disruption events, e.g. Swift J1644. The jet velocity is, however, too low to match the Lorentz factor γ > 2 inferred in J1644. There is no such conflict in the case of other tidal disruption events. Since favourably oriented observers see isotropic equivalent luminosities that are highly super-Eddington, the simulated models can explain observations of ultraluminous X-ray sources, at least in terms of luminosity and energetics, without requiring intermediate-mass BHs.
Xin, Daiyan; Talamini, Christine L; Raza, Ali S; de Moraes, Carlos Gustavo V; Greenstein, Vivienne C; Liebmann, Jeffrey M; Ritch, Robert; Hood, Donald C
2011-09-09
To better understand hypodense regions (holes) that appear in the retinal nerve fiber layer (RNFL) of frequency-domain optical coherence tomography (fdOCT) scans of patients with glaucoma and glaucoma suspects. Peripapillary circle (1.7-mm radius) and cube optic disc fdOCT scans were obtained on 208 eyes from 110 patients (57.4 ± 13.2 years) with glaucomatous optic neuropathy (GON) and 45 eyes of 45 controls (48.0 ± 12.6 years) with normal results of fundus examination. Holes in the RNFL were identified independently by two observers on the circle scans. Holes were found in 33 (16%) eyes of 28 (25%) patients; they were not found in any of the control eyes. Twenty-four eyes had more than one hole. Although some holes were relatively large, others were small. In general, the holes were located adjacent to blood vessels; only three eyes had isolated holes that were not adjacent to a vessel. The holes tended to be in the regions that are thickest in healthy controls and were associated with arcuate defects in patients. Holes were not seen in the center of the temporal disc region. They were more common in the superior (25 eyes) than in the inferior (15 eyes) disc. Of the 30 eyes with holes with reliable visual fields, seven were glaucoma suspect eyes with normal visual fields. The holes in the RNFL seen in patients with GON were probably due to a local loss of RNFL fibers and can occur in the eyes of glaucoma suspects with normal visual fields.
Mitry, Danny; Peto, Tunde; Hayat, Shabina; Blows, Peter; Morgan, James; Khaw, Kay-Tee; Foster, Paul J
2015-01-01
Crowdsourcing is the process of simplifying and outsourcing numerous tasks to many untrained individuals. Our aim was to assess the performance and repeatability of crowdsourcing in the classification of normal and glaucomatous discs from optic disc images. Optic disc images (N = 127) with pre-determined disease status were selected by consensus agreement from grading experts from a large cohort study. After reading brief illustrative instructions, we requested that knowledge workers (KWs) from a crowdsourcing platform (Amazon MTurk) classified each image as normal or abnormal. Each image was classified 20 times by different KWs. Two study designs were examined to assess the effect of varying KW experience and both study designs were conducted twice for consistency. Performance was assessed by comparing the sensitivity, specificity and area under the receiver operating characteristic curve (AUC). Overall, 2,540 classifications were received in under 24 hours at minimal cost. The sensitivity ranged between 83-88% across both trials and study designs, however the specificity was poor, ranging between 35-43%. In trial 1, the highest AUC (95%CI) was 0.64(0.62-0.66) and in trial 2 it was 0.63(0.61-0.65). There were no significant differences between study design or trials conducted. Crowdsourcing represents a cost-effective method of image analysis which demonstrates good repeatability and a high sensitivity. Optimisation of variables such as reward schemes, mode of image presentation, expanded response options and incorporation of training modules should be examined to determine their effect on the accuracy and reliability of this technique in retinal image analysis.
NASA Astrophysics Data System (ADS)
Kokubo, Mitsuru
2017-05-01
We examine the optical photometric and polarimetric variability of the luminous type 1 non-blazar quasar 3C 323.1 (PG 1545+210). Two optical spectropolarimetric measurements taken during the periods 1996-1998 and 2003 combined with a V-band imaging-polarimetric measurement taken in 2002 reveal that (1) as noted in the literature, the polarization of 3C 323.1 is confined only to the continuum emission, I.e. the emission from the broad-line region is unpolarized; (2) the polarized flux spectra show evidence of a time-variable broad absorption feature in the wavelength range of the Balmer continuum and other recombination lines; (3) weak variability in the polarization position angle (PA) of ˜4°over a time-scale of 4-6 yr is observed and (4) the V-band total flux and the polarized flux show highly correlated variability over a time-scale of 1 yr. Taking the above-mentioned photometric and polarimetric variability properties and the results from previous studies into consideration, we propose a geometrical model for the polarization source in 3C 323.1, in which an equatorial absorbing region and an axi-asymmetric equatorial electron-scattering region are assumed to be located between the accretion disc and the broad-line region. The scattering/absorbing regions can perhaps be attributed to the accretion disc wind or flared disc surface, but further polarimetric monitoring observations for 3C 323.1 and other quasars with continuum-confined polarization are needed to probe the true physical origins of these regions.
Angelo, D F; Morouço, P; Alves, N; Viana, T; Santos, F; González, R; Monje, F; Macias, D; Carrapiço, B; Sousa, R; Cavaco-Gonçalves, S; Salvado, F; Peleteiro, C; Pinho, M
2016-12-01
Preclinical trials are essential to the development of scientific technologies. Remarkable molecular and cellular research has been done using small animal models. However, significant differences exist regarding the articular behavior between these models and humans. Thus, large animal models may be more appropriate to perform trials involving the temporomandibular joint (TMJ). The aim of this work was to make a morphological (anatomic dissection and white light 3D scanning system), histological (TMJ in bloc was removed for histologic analysis) and biomechanical characterization (tension and compression tests) of sheep TMJ comparing the obtained results with human data. Results showed that sheep processus condylaris and fossa mandibularis are anatomically similar to the same human structures. TMJ disc has an elliptical perimeter, thinner in the center than in periphery. Peripheral area acts as a ring structure supporting the central zone. The disc cells display both fibroblast and chondrocyte-like morphology. Marginal area is formed by loose connective tissue, with some chondrocyte-like cells and collagen fibers in diverse orientations. Discs obtained a tensile modulus of 3.97±0.73MPa and 9.39±1.67MPa, for anteroposterior and mediolateral assessment. The TMJ discs presented a compressive modulus (E) of 446.41±5.16MPa and their maximum stress value (σmax) was 18.87±1.33MPa. Obtained results suggest that these animals should be considered as a prime model for TMJ research and procedural training. Further investigations in the field of oromaxillofacial surgery involving TMJ should consider sheep as a good animal model due to its resemblance of the same joint in humans. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Complex optical/UV and X-ray variability of the Seyfert 1 galaxy 1H 0419-577
NASA Astrophysics Data System (ADS)
Pal, Main; Dewangan, Gulab C.; Kembhavi, Ajit K.; Misra, Ranjeev; Naik, Sachindra
2018-01-01
We present detailed broad-band UV/optical to X-ray spectral variability of the Seyfert 1 galaxy 1H 0419-577 using six XMM-Newton observations performed during 2002-2003. These observations covered a large amplitude variability event in which the soft X-ray (0.3-2 keV) count rate increased by a factor of ∼4 in six months. The X-ray spectra during the variability are well described by a model consisting of a primary power law, blurred and distant reflection. The 2-10 keV power-law flux varied by a factor of ∼7 while the 0.3-2 keV soft X-ray excess flux derived from the blurred reflection component varied only by a factor of ∼2. The variability event was also observed in the optical and UV bands but the variability amplitudes were only at the 6-10 per cent level. The variations in the optical and UV bands appear to follow the variations in the X-ray band. During the rising phase, the optical bands appear to lag behind the UV band but during the declining phase, the optical bands appear to lead the UV band. Such behaviour is not expected in the reprocessing models where the optical/UV emission is the result of reprocessing of X-ray emission in the accretion disc. The delayed contribution of the broad emission lines in the UV band or the changes in the accretion disc/corona geometry combined with X-ray reprocessing may give rise to the observed behaviour of the variations.
Jadhav, Vivek Dattatray; Motwani, Bhagwan K.; Shinde, Jitendra; Adhapure, Prasad
2017-01-01
Aims: The aim of this study was to evaluate the marginal fit and surface roughness of complete cast crowns made by a conventional and an accelerated casting technique. Settings and Design: This study was divided into three parts. In Part I, the marginal fit of full metal crowns made by both casting techniques in the vertical direction was checked, in Part II, the fit of sectional metal crowns in the horizontal direction made by both casting techniques was checked, and in Part III, the surface roughness of disc-shaped metal plate specimens made by both casting techniques was checked. Materials and Methods: A conventional technique was compared with an accelerated technique. In Part I of the study, the marginal fit of the full metal crowns as well as in Part II, the horizontal fit of sectional metal crowns made by both casting techniques was determined, and in Part III, the surface roughness of castings made with the same techniques was compared. Statistical Analysis Used: The results of the t-test and independent sample test do not indicate statistically significant differences in the marginal discrepancy detected between the two casting techniques. Results: For the marginal discrepancy and surface roughness, crowns fabricated with the accelerated technique were significantly different from those fabricated with the conventional technique. Conclusions: Accelerated casting technique showed quite satisfactory results, but the conventional technique was superior in terms of marginal fit and surface roughness. PMID:29042726
The evolution of the disc variability along the hard state of the black hole transient GX 339-4
NASA Astrophysics Data System (ADS)
De Marco, B.; Ponti, G.; Muñoz-Darias, T.; Nandra, K.
2015-12-01
We report on the analysis of hard-state power spectral density function (PSD) of GX 339-4 down to the soft X-ray band, where the disc significantly contributes to the total emission. At any luminosity probed, the disc in the hard state is intrinsically more variable than in the soft state. However, the fast decrease of disc variability as a function of luminosity, combined with the increase of disc intensity, causes a net drop of fractional variability at high luminosities and low energies, which reminds the well-known behaviour of disc-dominated energy bands in the soft state. The peak frequency of the high-frequency Lorentzian (likely corresponding to the high-frequency break seen in active galactic nuclei, AGN) scales with luminosity, but we do not find evidence for a linear scaling. In addition, we observe that this characteristic frequency is energy dependent. We find that the normalization of the PSD at the peak of the high-frequency Lorentzian decreases with luminosity at all energies, though in the soft band this trend is steeper. Together with the frequency shift, this yields quasi-constant high-frequency (5-20 Hz) fractional rms at high energies, with less than 10 per cent scatter. This reinforces previous claims suggesting that the high-frequency PSD solely scales with black hole mass. On the other hand, this constancy breaks down in the soft band (where the scatter increases to ˜30 per cent). This is a consequence of the additional contribution from the disc component, and resembles the behaviour of optical variability in AGN.
Türkoğlu Saşmazel, Hilal; Aday, Sezin; Gümüşderelioğlu, Menemşe
2007-08-01
Insulin and/or heparin immobilized/co-immobilized non-woven polyester fabric (NWPF) discs were developed for the cultivation of L929 mouse fibroblasts in low-serum media. At first, NWPF discs were hydrolyzed to obtain a carboxylic acid group-introduced matrix (NWPF-hydrolyzed). Insulin and heparin co-immobilized NWPF (NWPF-insulin-heparin) was prepared by the grafting of PEO onto NWPF-hydrolyzed disc (NWPF-PEO), followed by the reaction first with insulin and then heparin. In the presence of spacer arm, PEO, the amount of immobilized insulin molecules significantly increased from 6.96 to 84.45 microg/cm(2). The amount of heparin bound to the NWPF-PEO (5.93 microg/cm(2)) was higher than that of the insulin immobilized surface (4.59 microg/cm(2)). Insulin and heparin immobilized NWPF discs were observed with fluorescence microscopy by labeling the insulin and heparin with 8-anilino-1-naphthalene sulfonic acid (ANS) or fluorescein isothiocyanate (FITC), respectively. L929 fibroblasts were used to check the cell adhesion and cell growth capabilities of modified NWPF discs in low-serum media (containing 5% fetal bovine serum). Optical photographs showed that after 2nd day of the culture, fibroblastic cells spread along the length of modified fibers, eventually filling the interfiber space. At the end of 6-day growth period, cell yield in the presence of immobilized heparin was a little bit higher than that of the immobilized insulin. Co-immobilized (insulin/heparin) NWPF discs did not accelerate the cell growth as well as insulin or heparin immobilized discs.
Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.
Wojtkowski, Maciej; Srinivasan, Vivek; Fujimoto, James G; Ko, Tony; Schuman, Joel S; Kowalczyk, Andrzej; Duker, Jay S
2005-10-01
To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain detection enables dramatic increases in imaging speeds. Three-dimensional OCT retinal imaging is performed in normal human subjects using high-speed ultrahigh-resolution OCT. Three-dimensional OCT data of the macula and optic disc are acquired using a dense raster scan pattern. New processing and display methods for generating virtual OCT fundus images; cross-sectional OCT images with arbitrary orientations; quantitative maps of retinal, nerve fiber layer, and other intraretinal layer thicknesses; and optic nerve head topographic parameters are demonstrated. Three-dimensional OCT imaging enables new imaging protocols that improve visualization and mapping of retinal microstructure. An OCT fundus image can be generated directly from the 3D OCT data, which enables precise and repeatable registration of cross-sectional OCT images and thickness maps with fundus features. Optical coherence tomography images with arbitrary orientations, such as circumpapillary scans, can be generated from 3D OCT data. Mapping of total retinal thickness and thicknesses of the nerve fiber layer, photoreceptor layer, and other intraretinal layers is demonstrated. Measurement of optic nerve head topography and disc parameters is also possible. Three-dimensional OCT enables measurements that are similar to those of standard instruments, including the StratusOCT, GDx, HRT, and RTA. Three-dimensional OCT imaging can be performed using high-speed ultrahigh-resolution OCT. Three-dimensional OCT provides comprehensive visualization and mapping of retinal microstructures. The high data acquisition speeds enable high-density data sets with large numbers of transverse positions on the retina, which reduces the possibility of missing focal pathologies. In addition to providing image information such as OCT cross-sectional images, OCT fundus images, and 3D rendering, quantitative measurement and mapping of intraretinal layer thickness and topographic features of the optic disc are possible. We hope that 3D OCT imaging may help to elucidate the structural changes associated with retinal disease as well as improve early diagnosis and monitoring of disease progression and response to treatment.
Sharing from Scratch: How To Network CD-ROM.
ERIC Educational Resources Information Center
Doering, David
1998-01-01
Examines common CD-ROM networking architectures: via existing operating systems (OS), thin server towers, and dedicated servers. Discusses digital video disc (DVD) and non-CD/DVD optical storage solutions and presents case studies of networks that work. (PEN)
Sagoo, Mandeep S; Shields, Carol L; Mashayekhi, Arman; Freire, Jorge; Emrich, Jacqueline; Reiff, Jay; Komarnicky, Lydia; Shields, Jerry A
2007-09-01
To report results of plaque radiotherapy for choroidal melanoma that completely encircles the optic disc (circumpapillary melanoma). Retrospective medical record review over a 31-year period of 37 consecutive patients. The main outcome measures were treatment complications, long-term visual acuity, enucleation, tumor recurrence, metastasis, and death. The median patient age at treatment was 69 years (range, 20-86 years). The presenting complaint was visual loss in 19 eyes (51%), photopsia in 5 (14%), and visual field loss in 3 (8%). All tumors touched and encircled the optic disc for 360 degrees . The quadrantic location of the main tumor epicenter was superior in 8 eyes (22%), nasal in 10 (27%), inferior in 9 (24%), and temporal in 10 (27%). The median tumor basal diameter was 11 mm (range, 4.8-20 mm) and median tumor thickness was 3.6 mm (range, 1.8-14.8 mm). The optic disc was obscured to some extent by overhanging tumor in 19 cases (52%). The most commonly used isotope for plaque radiotherapy was iodine 125 (n = 34 cases; 92%), and a notched plaque design was used in 34 cases (92%). Planned adjunctive treatment included transpupillary thermotherapy in 17 cases (49%) and argon laser photocoagulation in 6 of 35 cases (17%) with follow-up. Of the 28 eyes with more than 5 months' follow-up (mean, 52 months; median, 46 months; range, 5-234 months), treatment complications included nonproliferative and proliferative retinopathy in 11 (39%) and 7 eyes (25%); maculopathy in 7 (25%); papillopathy in 9 eyes (32%); neovascular glaucoma in 5 (18%); and vitreous hemorrhage in 13 (46%). Pars plana vitrectomy was required in only 2 of 13 eyes (15%) with persistent vitreous hemorrhage. Long-term visual acuity of 20/200 or worse was observed in 13 eyes (62%), and 12 eyes (57%) lost more than 5 Snellen visual acuity lines, excluding 7 cases (25%) in which enucleation was necessary. Recurrence was noted in 4 cases (14%), of which 3 were treated with enucleation and 1 with transpupillary thermotherapy. Systemic metastasis occurred in 1 patient (4%) and there were no melanoma-specific deaths during the study period. Custom-designed plaque radiotherapy is a potential treatment for selected patients with circumpapillary choroidal melanoma. We found satisfactory local tumor control, and globe retention was achieved in 75% of eyes with more than 5 months' follow-up.
Faraji, Foad; Heshmat, Haleh; Banava, Sepideh
2017-01-01
Background and Objectives: EQUIATM is a new gastrointestinal (GI) system with high compressive strength, surface microhardness (MH), and fluoride release potential. This in vitro study aimed to assess the effect of aging and type of protective coating on the MH of EQUIATM GI cement. Materials and Methods: A total of 30 disc-shaped specimens measuring 9 mm in diameter and 2 mm in thickness were fabricated of EQUIATM GI and divided into three groups of G-Coat nanofilled coating (a), no coating (b) and margin bond (c). The Vickers MH value of specimens was measured before (baseline) and at 3 and 6 months after water storage. Data were analyzed using repeated measures ANOVA. Results: Group B had significantly higher MH than the other two groups at baseline. Both G-Coat and margin bond increased the surface MH of GI at 3 and 6 months. The MH values of G-Coat and margin bond groups did not significantly increase or decrease between 3 and 6 months. Conclusion: The increase in MH was greater in the G-Coat compared to the margin bond group in the long-term. Clinically, margin bond may be a suitable alternative when G-Coat is not available. PMID:29259364
[Study on the effect of different impression methods on the marginal fit of all-ceramic crowns].
Zhan, Lilin; Zeng, Liwei; Chen, Ping; Liao, Lan; Li, Shiyue; Liu, Renying
2015-08-01
To investigate the effect of three different impression methods on the marginal fit of all-ceramic crowns. The three methods include scanning silicone rubber impression, cast models, and direct optical impression. The polymethyl methacrylate (PMMA) material of a mandibular first molar in standard model was prepared with 16 models duplicated. The all-ceramic crowns were prepared using three different impression methods. Accurate impressions were made using silicone rubber, and the cast models were obtained. The PMMA models, silicone rubber impressions, and cast models were scanned, and digital models of three groups were obtained to produce 48 zirconia all-ceramic crowns with computer aided design/computer aided manufacture. The marginal fit of these groups was measured by silicone rubber gap impression. Statistical analysis was performed with SPSS 17.0 software. The marginal fit of direct optical impression groups, silicone rubber impression groups, cast model groups was (69.18±9.47), (81.04±10.88), (84.42±9.96) µm. A significant difference was observed in the marginal fit of the direct optical impression groups and the other groups (P<0.05). No statistically significant difference was observed in the marginal fit of the silicone rubber impression groups and the cast model groups (P>0.05). All marginal measurement sites are clinically acceptable by the three different impression scanning methods. The silicone rubber impression scanning method can be used for all-ceramic restorations.
Brown, Stephen H M; Gregory, Diane E; McGill, Stuart M
2008-01-01
In a healthy spine, end-plate fractures occur from excessive pressurization of the intervening nucleus. Younger spines are most susceptible to such type of injury due to the highly hydraulic nature of their intervertebral discs. The purpose of this paper was to confirm this fracture mechanism of the healthy spine through the pressurization of the nucleus in the absence of external compressive loading. Sixteen functional porcine spine units were dissected and both injection and pressure transducer needles were inserted into the nucleus of the intervertebral disc. Hydraulic fluid was rapidly injected into the nucleus until failure occurred. Peak pressure and rate of pressure development were monitored. Spine units were dissected to determine the type and location of fracture. Fifteen of the 16 spine units fractured (the remaining unit had a degenerated disc). Of the 15 fractures, 13 occurred at the posterior margin of the end-plate along the lines of the growth plates. A slightly exponential relationship was found between peak pressure and its rate of development (R(2) = 0.544). Also, in each of the growth-plate fractured specimens, nuclear material was forcefully emitted, during fracture, from the intervertebral disc into the vertebral foramen. The posterior end-plate fractures produced here are similar to those often seen in young adult humans. This provides insight into a mechanism of fracture development through pressurization of the nucleus that might be seen in older adolescents and younger adults during athletic events or mild trauma.
Kim, Sabrina Y; Renihan, Maia K; Boulianne, Gabrielle L
2006-06-01
PDZ (PSD-95, Discs-large, ZO-1) domain proteins often function as scaffolding proteins and have been shown to play important roles in diverse cellular processes such as the establishment and maintenance of cell polarity, and signal transduction. Here, we report the identification and cloning of a novel Drosophila melanogaster gene that is predicted to produce several different PDZ domain-containing proteins through alternative promoter usage and alternative splicing. This gene, that we have named big bang (bbg), was first identified as C96-GAL4, a GAL4 enhancer trap line that was generated in our lab. To further characterize bbg, its expression pattern was examined in ovaries, embryos, and late third instar larvae using UAS reporter gene constructs, in situ hybridization, or immunocytochemistry. In addition, the expression of alternatively spliced transcripts was examined in more detail using in situ hybridization. We find that during embryogenesis bbg is predominantly expressed in the developing gut, but it is also expressed in external sensory organs found in the epidermis. In the late third instar larva, bbg is expressed along the presumptive wing margin in the wing disc, broadly in the eye disc, and in other imaginal discs as well as in the brain. The expression patterns observed are dynamic and specific during development, suggesting that like other genes that encode for several different PDZ domain protein isoforms, bbg likely plays important roles in multiple developmental processes.
A new triaenophorid tapeworm from blackfish Centrolophus niger.
Kuchta, Roman; Scholz, Tomás
2008-04-01
Milanella familiaris n. gen. and n. sp. (Bothriocephalidea: Triaenophoridae) is proposed to accommodate a new cestode from blackfish Centrolophus niger (Gmelin) (Perciformes: Centrolophidae). Milanella is characterized as follows: trapeziform, i.e., markedly craspedote proglottids with a velum-like posterior margin and horn like lateral projections; pyriform uterine sac in the first gravid proglottids; arrow-shaped scolex with well-developed apical disc and prominent posterior margins; strobila with intensively stained corpuscles, most numerous in the anterior part; deeply lobated ovary; absence of a neck; a large, pyriform, thin-walled cirrus-sac with the proximal part bent anteromedially; vagina posterior to the cirrus-sac; and cortical vitelline follicles. Milanella most closely resembles Bathycestus Kuchta and Scholz, 2004, Pistana Campbell and Gartner, 1982, and Probothriocephalus Campbell, 1979, differing mainly in the shape of proglottids and uterine sac.
Raman mediated all-optical cascadable inverter using silicon-on-insulator waveguides.
Sen, Mrinal; Das, Mukul K
2013-12-01
In this Letter, we propose an all-optical circuit for a cascadable and integrable logic inverter based on stimulated Raman scattering. A maximum product criteria for noise margin is taken to analyze the cascadability of the inverter. Variation of noise margin for different model parameters is also studied. Finally, the time domain response of the inverter is analyzed for different widths of input pulses.
Transient events in bright debris discs: Collisional avalanches revisited
NASA Astrophysics Data System (ADS)
Thebault, P.; Kral, Q.
2018-01-01
Context. A collisional avalanche is set off by the breakup of a large planetesimal, releasing vast amounts of small unbound grains that enter a debris disc located further away from the star, triggering there a collisional chain reaction that could potentially create detectable transient structures. Aims: We investigate this mechanism, using for the first time a fully self-consistent code coupling dynamical and collisional evolutions. We also quantify for the first time the photometric evolution of the system and investigate whether or not avalanches could explain the short-term luminosity variations recently observed in some extremely bright debris discs. Methods: We use the state-of-the-art LIDT-DD code. We consider an avalanche-favoring A6V star, and two set-ups: a "cold disc" case, with a dust release at 10 au and an outer disc extending from 50 to 120 au, and a "warm disc" case with the release at 1 au and a 5-12 au outer disc. We explore, in addition, two key parameters: the density (parameterized by its optical depth τ) of the main outer disc and the amount of dust released by the initial breakup. Results: We find that avalanches could leave detectable structures on resolved images, for both "cold" and "warm" disc cases, in discs with τ of a few 10-3, provided that large dust masses (≳1020-5 × 1022 g) are initially released. The integrated photometric excess due to an avalanche is relatively limited, less than 10% for these released dust masses, peaking in the λ 10-20 μm domain and becoming insignificant beyond 40-50 μm. Contrary to earlier studies, we do not obtain stronger avalanches when increasing τ to higher values. Likewise, we do not observe a significant luminosity deficit, as compared to the pre-avalanche level, after the passage of the avalanche. These two results concur to make avalanches an unlikely explanation for the sharp luminosity drops observed in some extremely bright debris discs. The ideal configuration for observing an avalanche would be a two-belt structure, with an inner belt (at 1 or 10 au for the "warm" and "cold" disc cases, respectively) of fractional luminosity f ≳ 10-4 where breakups of massive planetesimals occur, and a more massive outer belt, with τ of a few 10-3, into which the avalanche chain reaction develops and propagates.
Video Discs: Magic Lamps for Educators?
ERIC Educational Resources Information Center
Braun,
1978-01-01
This article focuses on electro-optical videodisc systems because of their educational advantages over electromechanical systems and specifically on the Philips/MCA system. Areas emerging for videodisc educational application are identified as lenear video, programed instruction, and interactive use with the computer. (CMV)
University Faculty Teaching Activities in an Electronic Curriculum.
ERIC Educational Resources Information Center
Eisner, John; Carter, Thomas
1989-01-01
Discusses the changes in the instructional activities of university faculty members as a result of new computer-related educational technologies. Topics discussed include computer-assisted instruction; computer-managed instruction; optical discs; microcomputers; lecturing versus computer-based tutorials; videodiscs; computerized evaluative…
NASA Astrophysics Data System (ADS)
Zanello, Marc; Poulon, Fanny; Pallud, Johan; Varlet, Pascale; Hamzeh, H.; Abi Lahoud, Georges; Andreiuolo, Felipe; Ibrahim, Ali; Pages, Mélanie; Chretien, Fabrice; di Rocco, Federico; Dezamis, Edouard; Nataf, François; Turak, Baris; Devaux, Bertrand; Abi Haidar, Darine
2017-02-01
Delineating tumor margins as accurately as possible is of primordial importance in surgical oncology: extent of resection is associated with survival but respect of healthy surrounding tissue is necessary for preserved quality of life. The real-time analysis of the endogeneous fluorescence signal of brain tissues is a promising tool for defining margins of brain tumors. The present study aims to demonstrate the feasibility of multimodal optical analysis to discriminate fresh samples of gliomas, metastases and meningiomas from their appropriate controls. Tumor samples were studied on an optical fibered endoscope using spectral and fluorescence lifetime analysis and then on a multimodal set-up for acquiring spectral, one and two-photon fluorescence images, second harmonic generation signals and two-photon fluorescence lifetime datasets. The obtained data allowed us to differentiate healthy samples from tumor samples. These results confirmed the possible clinical relevance of this real-time multimodal optical analysis. This technique can be easily applied to neurosurgical procedures for a better delineation of surgical margins.
Attig, J.W.; Hanson, P.R.; Rawling, J.E.; Young, A.R.; Carson, E.C.
2011-01-01
Samples for optical dating were collected to estimate the time of sediment deposition in small ice-marginal lakes in the Baraboo Hills of Wisconsin. These lakes formed high in the Baraboo Hills when drainage was blocked by the Green Bay Lobe when it was at or very near its maximum extent. Therefore, these optical ages provide control for the timing of the thinning and recession of the Green Bay Lobe from its maximum position. Sediment that accumulated in four small ice-marginal lakes was sampled and dated. Difficulties with field sampling and estimating dose rates made the interpretation of optical ages derived from samples from two of the lake basins problematic. Samples from the other two lake basins-South Bluff and Feltz basins-responded well during laboratory analysis and showed reasonably good agreement between the multiple ages produced at each site. These ages averaged 18.2. ka (n= 6) and 18.6. ka (n= 6), respectively. The optical ages from these two lake basins where we could carefully select sediment samples provide firm evidence that the Green Bay Lobe stood at or very near its maximum extent until about 18.5. ka.The persistence of ice-marginal lakes in these basins high in the Baraboo Hills indicates that the ice of the Green Bay Lobe had not experienced significant thinning near its margin prior to about 18.5. ka. These ages are the first to directly constrain the timing of the maximum extent of the Green Bay Lobe and the onset of deglaciation in the area for which the Wisconsin Glaciation was named. ?? 2011 Elsevier B.V.
PITX2 and NODAL expression during axis formation in the early rabbit embryo.
Plöger, Ruben; Viebahn, Christoph
2018-04-26
Attaining molecular and morphological axial polarity during gastrulation is a fundamental early requirement for normal development of the embryo. In mammals, the first morphological sign of the anterior-posterior axis appears anteriorly in the form of the anterior marginal crescent (or anterior visceral endoderm) while in the avian the first such sign is the Koller's sickle at the posterior pole of the embryonic disc. Despite this inverse mode of axis formation many genes and molecular pathways involved in various steps of this process seem to be evolutionary conserved amongst amniotes, the nodal gene being a well-known example with its functional involvement prior and during gastrulation. The pitx2 gene, however, is a new candidate described in the chick as an early marker for anterior-posterior polarity and as regulator of axis formation including twinning. To find out whether pitx2 has retained its inductive and early marker function during the evolution of mammals, this study analyzes pitx2 and nodal expression at parallel stages during formation of the anterior-posterior polarity in the early rabbit embryo using whole-mount in situ hybridization and serial light-microscopical sections. At a late pre-gastrulation stage a localized reduction of nodal expression presages the position of the anterior pole of the embryonic disc and thus serves as the earliest molecular marker of anterior-posterior polarity known so far. pitx2 is expressed in a polarized manner in the anterior marginal crescent and in the posterior half of the embryonic disc during further development only while nodal expression in the anterior segment of the posterior pitx2 expression domain helps to define the so-called anterior streak domain (ASD), a novel progenitor region of the anterior half of the primitive streak. The expression patterns of both genes thus serve as signs of a conserved involvement in early axis formation in amniotes and, possibly, in twinning in mammals as well. Copyright © 2018 Elsevier GmbH. All rights reserved.
Zayit-Soudry, Shiri; Duncan, Jacque L; Syed, Reema; Menghini, Moreno; Roorda, Austin J
2013-11-15
To evaluate cone spacing using adaptive optics scanning laser ophthalmoscopy (AOSLO) in eyes with nonneovascular AMD, and to correlate progression of AOSLO-derived cone measures with standard measures of macular structure. Adaptive optics scanning laser ophthalmoscopy images were obtained over 12 to 21 months from seven patients with AMD including four eyes with geographic atrophy (GA) and four eyes with drusen. Adaptive optics scanning laser ophthalmoscopy images were overlaid with color, infrared, and autofluorescence fundus photographs and spectral domain optical coherence tomography (SD-OCT) images to allow direct correlation of cone parameters with macular structure. Cone spacing was measured for each visit in selected regions including areas over drusen (n = 29), at GA margins (n = 14), and regions without drusen or GA (n = 13) and compared with normal, age-similar values. Adaptive optics scanning laser ophthalmoscopy imaging revealed continuous cone mosaics up to the GA edge and overlying drusen, although reduced cone reflectivity often resulted in hyporeflective AOSLO signals at these locations. Baseline cone spacing measures were normal in 13/13 unaffected regions, 26/28 drusen regions, and 12/14 GA margin regions. Although standard clinical measures showed progression of GA in all study eyes, cone spacing remained within normal ranges in most drusen regions and all GA margin regions. Adaptive optics scanning laser ophthalmoscopy provides adequate resolution for quantitative measurement of cone spacing at the margin of GA and over drusen in eyes with AMD. Although cone spacing was often normal at baseline and remained normal over time, these regions showed focal areas of decreased cone reflectivity. These findings may provide insight into the pathophysiology of AMD progression. (ClinicalTrials.gov number, NCT00254605).
Single-cell isolation using a DVD optical pickup
Kasukurti, A.; Potcoava, M.; Desai, S.A.; Eggleton, C.; Marr, D. W. M.
2011-01-01
A low-cost single-cell isolation system incorporating a digital versatile disc burner (DVD RW) optical pickup has been developed. We show that these readily available modules have the required laser power and focusing optics to provide a steady Gaussian beam capable of optically trapping micron-sized colloids and red blood cells. Utility of the pickup is demonstrated through the non-destructive isolation of such particles in a laminar-flow based microfluidic device that captures and translates single microscale objects across streamlines into designated channel exits. In this, the integrated objective lens focusing coils are used to steer the optical trap across the channel, resulting in the isolation of colloids and red blood cells using a very inexpensive off-the-shelf optical component. PMID:21643294
Rai, Rathika; Kumar, S Arun; Prabhu, R; Govindan, Ranjani Thillai; Tanveer, Faiz Mohamed
2017-01-01
Accuracy in fit of cast metal restoration has always remained as one of the primary factors in determining the success of the restoration. A well-fitting restoration needs to be accurate both along its margin and with regard to its internal surface. The aim of the study is to evaluate the marginal fit of metal ceramic crowns obtained by conventional inlay casting wax pattern using conventional impression with the metal ceramic crowns obtained by computer-aided design and computer-aided manufacturing (CAD/CAM) technique using direct and indirect optical scanning. This in vitro study on preformed custom-made stainless steel models with former assembly that resembles prepared tooth surfaces of standardized dimensions comprised three groups: the first group included ten samples of metal ceramic crowns fabricated with conventional technique, the second group included CAD/CAM-milled direct metal laser sintering (DMLS) crowns using indirect scanning, and the third group included DMLS crowns fabricated by direct scanning of the stainless steel model. The vertical marginal gap and the internal gap were evaluated with the stereomicroscope (Zoomstar 4); post hoc Turkey's test was used for statistical analysis. One-way analysis of variance method was used to compare the mean values. Metal ceramic crowns obtained from direct optical scanning showed the least marginal and internal gap when compared to the castings obtained from inlay casting wax and indirect optical scanning. Indirect and direct optical scanning had yielded results within clinically acceptable range.
Mondal, Suman B.; Gao, Shengkui; Zhu, Nan; Hebimana-Griffin, LeMoyne; Akers, Walter J.; Liang, Rongguang; Gruev, Viktor; Margenthaler, Julie; Achilefu, Samuel
2017-01-01
Background The inability to directly visualize the patient and surgical site limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment. Methods We evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided popliteal lymph node resection. Four breast cancer patients received 99mTc-sulfur colloid and indocyanine green retroareolarly, before undergoing sentinel lymph node biopsy using radioactive tracking and fluorescence imaging. Three other breast cancer patients received indocyanine green retroareolarly before undergoing standard-of-care partial mastectomy, followed by fluorescence imaging of resected tumor and tumor cavity for margin assessment. Results Using near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and 4 pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin embedded section histopathology. Conclusions The optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room. PMID:28213790
Mondal, Suman B; Gao, Shengkui; Zhu, Nan; Habimana-Griffin, LeMoyne; Akers, Walter J; Liang, Rongguang; Gruev, Viktor; Margenthaler, Julie; Achilefu, Samuel
2017-07-01
The inability to visualize the patient and surgical site directly, limits the use of current near infrared fluorescence-guided surgery systems for real-time sentinel lymph node biopsy and tumor margin assessment. We evaluated an optical see-through goggle augmented imaging and navigation system (GAINS) for near-infrared, fluorescence-guided surgery. Tumor-bearing mice injected with a near infrared cancer-targeting agent underwent fluorescence-guided, tumor resection. Female Yorkshire pigs received hind leg intradermal indocyanine green injection and underwent fluorescence-guided, popliteal lymph node resection. Four breast cancer patients received 99m Tc-sulfur colloid and indocyanine green retroareolarly before undergoing sentinel lymph node biopsy using radioactive tracking and fluorescence imaging. Three other breast cancer patients received indocyanine green retroareolarly before undergoing standard-of-care partial mastectomy, followed by fluorescence imaging of resected tumor and tumor cavity for margin assessment. Using near-infrared fluorescence from the dyes, the optical see-through GAINS accurately identified all mouse tumors, pig lymphatics, and four pig popliteal lymph nodes with high signal-to-background ratio. In 4 human breast cancer patients, 11 sentinel lymph nodes were identified with a detection sensitivity of 86.67 ± 0.27% for radioactive tracking and 100% for GAINS. Tumor margin status was accurately predicted by GAINS in all three patients, including clear margins in patients 1 and 2 and positive margins in patient 3 as confirmed by paraffin-embedded section histopathology. The optical see-through GAINS prototype enhances near infrared fluorescence-guided surgery for sentinel lymph node biopsy and tumor margin assessment in breast cancer patients without disrupting the surgical workflow in the operating room.
NASA Astrophysics Data System (ADS)
Iftimia, Nicusor V.; Park, Jesung; Maguluri, Gopi N.; Krishnamurthy, Savitri
2017-02-01
A novel multimodal optical imaging approach for real-time assessment of surgical margins on breast cancer lumpectomy specimens is presented. Our approach is to target cancer cells using an optically silent peptide substrate containing two (NIR) fluorochromes, internally quenched, which are cleaved by highly expressed breast cancer enzymes, like urokinase-type plasminogen activator (uPA). Thus this agent becomes highly fluorescent only on the cancer area when the specimen is excited by a NIR laser beam. A fluorescence imager is used to highlight cancer-suspect margins on the surgical specimen, while high-resolution optical coherence tomography (OCT) imaging is used to visualize tissue morphology on the highlighted areas and confirm or rule out cancer presence. This technology will hopefully increase the success rate of cancer surgeries, reduce the risk of cancer recurrence and significantly reduce US healthcare costs.
Photometric variability in FU Ori and Z CMa as observed by MOST
NASA Astrophysics Data System (ADS)
Siwak, Michal; Rucinski, Slavek M.; Matthews, Jaymie M.; Kuschnig, Rainer; Guenther, David B.; Moffat, Anthony F. J.; Rowe, Jason F.; Sasselov, Dimitar; Weiss, Werner W.
2013-06-01
Photometric observations obtained by the MOST satellite were used to characterize optical small-scale variability of the young stars FU Ori and Z CMa. Wavelet analysis for FU Ori reveals the possible existence of several 2-9 d quasi-periodic features occurring nearly simultaneously; they may be interpreted as plasma parcels or other localized disc heterogeneities revolving at different Keplerian radii in the accretion disc. Their periods may shorten slowly which may be due to spiralling in of individual parcels towards the inner disc radius, estimated at 4.8 ± 0.2 R⊙. Analysis of additional multicolour data confirms the previously obtained relation between variations in the B - V colour index and the V magnitude. In contrast to the FU Ori results, the oscillation spectrum of Z CMa does not reveal any periodicities with the wavelet spectrum possibly dominated by outburst of the Herbig Be component.
The shape of dark matter haloes - IV. The structure of stellar discs in edge-on galaxies
NASA Astrophysics Data System (ADS)
Peters, S. P. C.; de Geyter, G.; van der Kruit, P. C.; Freeman, K. C.
2017-01-01
We present optical and near-infrared archival observations of eight edge-on galaxies. These observations are used to model the stellar content of each galaxy using the FITSKIRT software package. Using FITSKIRT, we can self-consistently model a galaxy in each band simultaneously while treating for dust. This allows us to measure accurately both the scalelength and scaleheight of the stellar disc, plus the shape parameters of the bulge. By combining these data with the previously reported integrated magnitudes of each galaxy, we can infer their true luminosities. We have successfully modelled seven out of the eight galaxies in our sample. We find that stellar discs can be modelled correctly, but we have not been able to model the stellar bulge reliably. Our sample consists for the most part of slowly rotating galaxies and we find that the average dust layer is much thicker than is reported for faster rotating galaxies.
υ-driven winds from the remnant of binary neutron star mergers
NASA Astrophysics Data System (ADS)
Perego, A.
2018-01-01
We present a 3D hydrodynamic study of the neutrino-driven winds that emerge from the remnant of a neutron star merger, represented by a thick accretion disc orbiting around a massive neutron star. This strong baryonic wind is blown out by neutrino absorption on free baryons inside the disc. It expands within a few tens of ms along the original binary rotation axis. If the central object survives for at least 200ms, the mass ejected in the wind can reach 5% of the initial mass of the accretion disc. Due to the intense neutrino irradiation, matter ejected in the wind increases its electron fraction between 0.3 and 0.4, producing weak r-process nucleosynthesis yields. We predict a distinct UV/optical transient associated with the wind ejecta that peaks from a few hours to a few days after the merger.
Weng, Christina Y; Khimani, Karima S; Foroozan, Rod; Gospe, Sidney M; Bhatti, M Tariq
2018-04-26
An 81-year-old man with bilateral progressively blurry vision and optic disc swelling was referred for evaluation. Examination and ancillary testing confirmed a diagnosis of bilateral vitreopapillary traction (VPT) accompanied by unilateral tractional retinoschisis in the right eye. Pars plana vitrectomy was performed to release the traction in both eyes. Visual acuity improved in the right eye and stabilized in the left eye. Retinoschisis in the right eye resolved. The visual field improved in both eyes, although the left eye demonstrated a persistent hemifield defect likely attributable to a prior optic neuropathy. Distinguishing VPT optic neuropathy (VPTON) from nonarteritic anterior ischemic optic neuropathy (NAION) is discussed. Copyright © 2018 Elsevier Inc. All rights reserved.
Optic Nerve Assessment Using 7-Tesla Magnetic Resonance Imaging.
Singh, Arun D; Platt, Sean M; Lystad, Lisa; Lowe, Mark; Oh, Sehong; Jones, Stephen E; Alzahrani, Yahya; Plesec, Thomas
2016-04-01
The purpose of this study was to correlate high-resolution magnetic resonance imaging (MRI) and histologic findings in a case of juxtapapillary choroidal melanoma with clinical evidence of optic nerve invasion. With institutional review board approval, an enucleated globe with choroidal melanoma and optic nerve invasion was imaged using a 7-tesla MRI followed by histopathologic evaluation. Optical coherence tomography, B-scan ultrasonography, and 1.5-tesla MRI of the orbit (1-mm sections) could not detect optic disc invasion. Ex vivo, 7-tesla MRI detected optic nerve invasion, which correlated with histopathologic features. Our case demonstrates the potential to document the existence of optic nerve invasion in the presence of an intraocular tumor, a feature that has a major bearing on decision making, particularly for consideration of enucleation.
PKS 2123-463: A Confirmed Gamma-ray Blazar at High Redshift
NASA Technical Reports Server (NTRS)
D'Ammando, F.; Rau, A.; Schady, P.; Finke, J.; Orienti, M.; Greiner, J.; Kann, D. A.; Ojha, R.; Foley, A. R.; Stevens, J.;
2013-01-01
The flat spectrum radio quasar (FSRQ) PKS 2123-463 was associated in the first Fermi- Large Area Telescope (LAT) source catalogue with the gamma-ray source 1FGL J2126.1-4603, but when considering the full first two years of Fermi observations, no gamma-ray source at a position consistent with this FSRQ was detected, and thus PKS 2123-463 was not reported in the second Fermi-LAT source catalogue. On 2011 December 14 a gamma-ray source positionally consistent with PKS 2123-463 was detected in flaring activity by Fermi-LAT. This activity triggered radio-to-X-ray observations by the Swift,Gamma-ray Optical/Near-Infrared Detector (GROND), Australia Telescope Compact Array (ATCA), Ceduna and Seven Dishes Karoo Array Telescope (KAT-7) observatories. Results of the localization of the gamma-ray source over 41 months of Fermi-LAT operation are reported here in conjunction with the results of the analysis of radio, optical, ultraviolet (UV) and X-ray data collected soon after the gamma-ray flare. The strict spatial association with the lower energy counterpart together with a simultaneous increase of the activity in optical, UV, X-ray and gamma-ray bands led to a firm identification of the gamma-ray source with PKS 2123-463. A new photometric redshift has been estimated as z = 1.46 plus or minus 0.05 using GROND and Swift Ultraviolet/Optical Telescope (UVOT) observations, in rough agreement with the disputed spectroscopic redshift of z = 1.67.We fit the broad-band spectral energy distribution with a synchrotron/external Compton model. We find that a thermal disc component is necessary to explain the optical/UV emission detected by Swift/UVOT. This disc has a luminosity of approximately 1.8 x 10(exp 46) erg s(exp -1), and a fit to the disc emission assuming a Schwarzschild (i.e. non-rotating) black hole gives a mass of approximately 2 x 10(exp 9) solar mass. This is the first black hole mass estimate for this source.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
... Cliffs, NJ 07632. Nintendo Co., Ltd., 11-1 Hokotate-cho, Kamitoba, Minami-ku, Kyoto 601- 8501, Japan. Nintendo of America, Inc., 4600 150th Avenue NE, Redmond, WA 98052- 5113. Panasonic Corp., 1006, Oaza...
New Information Technologies: Possible Implications for Libraries.
ERIC Educational Resources Information Center
de Stricker, Ulla
1998-01-01
Presents observations about developments in information technology that will influence the information industry and libraries of the future. Discusses search engine capabilities; push technology; electronic commerce; WebTV; and optical discs with links to Web sites. Ten figures provide illustrations and charts. (AEF)